Sample records for device offers additional

  1. S-Band POSIX Device Drivers for RTEMS

    NASA Technical Reports Server (NTRS)

    Lux, James P.; Lang, Minh; Peters, Kenneth J.; Taylor, Gregory H.

    2011-01-01

    This is a set of POSIX device driver level abstractions in the RTEMS RTOS (Real-Time Executive for Multiprocessor Systems real-time operating system) to SBand radio hardware devices that have been instantiated in an FPGA (field-programmable gate array). These include A/D (analog-to-digital) sample capture, D/A (digital-to-analog) sample playback, PLL (phase-locked-loop) tuning, and PWM (pulse-width-modulation)-controlled gain. This software interfaces to Sband radio hardware in an attached Xilinx Virtex-2 FPGA. It uses plug-and-play device discovery to map memory to device IDs. Instead of interacting with hardware devices directly, using direct-memory mapped access at the application level, this driver provides an application programming interface (API) offering that easily uses standard POSIX function calls. This simplifies application programming, enables portability, and offers an additional level of protection to the hardware. There are three separate device drivers included in this package: sband_device (ADC capture and DAC playback), pll_device (RF front end PLL tuning), and pwm_device (RF front end AGC control).

  2. Investigation of charge coupled device correlation techniques

    NASA Technical Reports Server (NTRS)

    Lampe, D. R.; Lin, H. C.; Shutt, T. J.

    1978-01-01

    Analog Charge Transfer Devices (CTD's) offer unique advantages to signal processing systems, which often have large development costs, making it desirable to define those devices which can be developed for general system's use. Such devices are best identified and developed early to give system's designers some interchangeable subsystem blocks, not requiring additional individual development for each new signal processing system. The objective of this work is to describe a discrete analog signal processing device with a reasonably broad system use and to implement its design, fabrication, and testing.

  3. Augmented paper maps: Exploring the design space of a mixed reality system

    NASA Astrophysics Data System (ADS)

    Paelke, Volker; Sester, Monika

    Paper maps and mobile electronic devices have complementary strengths and shortcomings in outdoor use. In many scenarios, like small craft sailing or cross-country trekking, a complete replacement of maps is neither useful nor desirable. Paper maps are fail-safe, relatively cheap, offer superior resolution and provide large scale overview. In uses like open-water sailing it is therefore mandatory to carry adequate maps/charts. GPS based mobile devices, on the other hand, offer useful features like automatic positioning and plotting, real-time information update and dynamic adaptation to user requirements. While paper maps are now commonly used in combination with mobile GPS devices, there is no meaningful integration between the two, and the combined use leads to a number of interaction problems and potential safety issues. In this paper we explore the design space of augmented paper maps in which maps are augmented with additional functionality through a mobile device to achieve a meaningful integration between device and map that combines their respective strengths.

  4. Opportunities for nonvolatile memory systems in extreme-scale high-performance computing

    DOE PAGES

    Vetter, Jeffrey S.; Mittal, Sparsh

    2015-01-12

    For extreme-scale high-performance computing systems, system-wide power consumption has been identified as one of the key constraints moving forward, where DRAM main memory systems account for about 30 to 50 percent of a node's overall power consumption. As the benefits of device scaling for DRAM memory slow, it will become increasingly difficult to keep memory capacities balanced with increasing computational rates offered by next-generation processors. However, several emerging memory technologies related to nonvolatile memory (NVM) devices are being investigated as an alternative for DRAM. Moving forward, NVM devices could offer solutions for HPC architectures. Researchers are investigating how to integratemore » these emerging technologies into future extreme-scale HPC systems and how to expose these capabilities in the software stack and applications. In addition, current results show several of these strategies could offer high-bandwidth I/O, larger main memory capacities, persistent data structures, and new approaches for application resilience and output postprocessing, such as transaction-based incremental checkpointing and in situ visualization, respectively.« less

  5. Endovascular stent-graft repair of failed endovascular abdominal aortic aneurysm repair.

    PubMed

    Baril, Donald T; Silverberg, Daniel; Ellozy, Sharif H; Carroccio, Alfio; Jacobs, Tikva S; Sachdev, Ulka; Teodorescu, Victoria J; Lookstein, Robert A; Marin, Michael L

    2008-01-01

    Despite high initial technical success, the long-term durability of endovascular abdominal aortic aneurysm repair (EVAR) continues to be a concern. Following EVAR, patients can experience endoleaks, device migration, device fractures, or aneurysm growth that may require intervention. The purpose of this study was to review all patients treated with secondary endovascular devices at our institution for failed EVAR procedures. Over an 8-year period, 988 patients underwent EVAR, of whom 42 (4.3%) required secondary interventions involving placement of additional endovascular devices. Data regarding patient characteristics, aneurysm size, initial device type, time until failure, failure etiology, secondary interventions, and outcomes were reviewed. The mean time from initial operation until second operation was 34.1 months. Failures included type I endoleaks in 38 patients (90.5%), type III endoleaks in two patients (4.8%), and enlarging aneurysms without definite endoleaks in two patients (4.8%). The overall technical success rate for secondary repair was 92.9% (39/42). Perioperative complications occurred in nine patients (21.4%), including wound complications (n = 6), cerebrovascular accident (CVA) (n = 1), foot drop (n = 1), and death (n = 1). Mean follow-up following secondary repair was 16.4 months (range 1-50). Eighty-six percent of patients treated with aortouni-iliac devices had successful repairs compared to 45% of patients treated with proximal cuffs. Ten patients (23.8%) had persistent or recurrent type I or type III endoleaks following revision. Of these, four had tertiary interventions, including two patients who had additional devices placed. Failures following EVAR occur in a small but significant number of patients. When anatomically possible, endovascular revision offers a safe means of treating these failures. Aortouni-iliac devices appear to offer a more durable repair than the proximal cuff for treatment of proximal type I endoleaks. Midterm results indicate that these patients may require additional procedures but have a low rate of aneurysm-related mortality. Longer-term follow-up is necessary to determine the durability of these endovascular revisions.

  6. Introduction to Semiconductor Devices

    NASA Astrophysics Data System (ADS)

    Brennan, Kevin F.

    2005-03-01

    This volume offers a solid foundation for understanding the most important devices used in the hottest areas of electronic engineering today, from semiconductor fundamentals to state-of-the-art semiconductor devices in the telecommunications and computing industries. Kevin Brennan describes future approaches to computing hardware and RF power amplifiers, and explains how emerging trends and system demands of computing and telecommunications systems influence the choice, design and operation of semiconductor devices. In addition, he covers MODFETs and MOSFETs, short channel effects, and the challenges faced by continuing miniaturization. His book is both an excellent senior/graduate text and a valuable reference for practicing engineers and researchers.

  7. Recommendations from Friends Anytime and Anywhere: Toward a Model of Contextual Offer and Consumption Values

    PubMed Central

    Shen, Xiao-Liang; Wang, Nan

    2013-01-01

    Abstract The ubiquity and portability of mobile devices provide additional opportunities for information retrieval. People can easily access mobile applications anytime and anywhere when they need to acquire specific context-aware recommendations (contextual offer) from their friends. This study, thus, represents an initial attempt to understand users' acceptance of a mobile-based social reviews platform, where recommendations from friends can be obtained with mobile devices. Based on the consumption value theory, a theoretical model is proposed and empirically examined using survey data from 218 mobile users. The findings demonstrate that contextual offers based on users' profiles, access time, and geographic positions significantly predict their value perceptions (utilitarian, hedonic, and social), which, in turn, affect their intention to use a mobile social reviews platform. This study is also believed to provide some useful insights to both research and practice. PMID:23530548

  8. Promoting Reading: Using eBooks with Gifted and Advanced Readers

    ERIC Educational Resources Information Center

    Weber, Christine L.; Cavanaugh, Terence W.

    2006-01-01

    eBooks are textual documents that have been converted and "published" in an electronic format and are displayed on eBook readers, devices, or computers using eBook software programs. This new form of book is a relatively recent addition to book styles and offers students, teachers, and schools an additional tool for the teaching of reading and the…

  9. How smart should pacemakers Be?

    PubMed

    Saoudi, N; Appl, U; Anselme, F; Voglimacci, M; Cribier, A

    1999-03-11

    The concept of the "smart" pacemaker has been continuously changing during 40 years of progress in technology. When we talk today about smart pacemakers, it means optimal treatment, diagnosis, and follow-up for patients fitting the current indications for pacemakers. So what is smart today becomes accepted as "state of the art" tomorrow. Originally, implantable pacemakers were developed to save lives from prolonged episodes of bradycardia and/or complete heart block. Now, in addition, they improve quality of life via numerous different functions acting under specific conditions, thanks to the introduction of microprocessors. The devices have become smaller, with the miniaturization of the electrical components, without compromising longevity. Nevertheless, there are still some unmatched objectives for these devices, for example, the optimization of cardiac output and the management of atrial arrhythmias in dual-chamber devices. Furthermore, indications continue to evolve, which in turn require new, additional functions. These functions are often very complex, necessitating computerized programming to simplify application. In addition, the follow-up of these devices is time-consuming, as appropriate system performance has to be regularly monitored. A great many of these functions could be automatically performed and documented, thus enabling physicians and paramedical staff to avoid losing time with routine control procedures. In addition, modern pacemakers offer extensive diagnostic functions to help diagnose patient symptoms and pacemaker system problems. Different types of data are available, and their presentation differs from one company to the other. This huge amount of data can only be managed with automatic diagnostic functions. Thus, the smart pacemaker of the near future should offer high flexibility to permit easy programming of available therapies and follow-up, and extensive, easily comprehensible diagnostic functions.

  10. Some Middle School Students Want Behavior Commitment Devices (but Take-Up Does Not Affect Their Behavior)

    PubMed Central

    Robinson, Carly D.; Pons, Gonzalo A.; Duckworth, Angela L.; Rogers, Todd

    2018-01-01

    Commitment devices impose costs on one's future self for failing to follow through on one's intentions, offer no additional benefit to one's future self for following through on the intention, and people voluntarily enroll in them. Enrollment in commitment devices reflects self-awareness that one may lack sufficient self-control to fulfill one's intentions. There is little experimental research on whether school-age children possess the self-awareness necessary to enroll in a commitment device, despite evidence that children and young adolescents have many positive intentions that they fail to live up to, such as demonstrating improved school conduct or eating healthier. We report the first field experiment examining the demand for, and impact of, commitment devices among middle school students. We offered students a commitment device that imposed future costs for failing to improve in-school conduct. When presented with the opportunity to actively opt-in (default not enrolled), over one-third of students elected to enroll. When presented with the opportunity to actively opt-out (default enrolled), more than half elected to remain enrolled, showing that changing default options can increase commitment device enrollment. Despite demand for the self-control strategy, taking-up the commitment device did not affect student behavior. These findings have implications for youth-based behavioral interventions broadly, as well as those focused on eating behaviors. PMID:29541040

  11. Preliminary study of the reliability of imaging charge coupled devices

    NASA Technical Reports Server (NTRS)

    Beall, J. R.; Borenstein, M. D.; Homan, R. A.; Johnson, D. L.; Wilson, D. D.; Young, V. F.

    1978-01-01

    Imaging CCDs are capable of low light level response and high signal-to-noise ratios. In space applications they offer the user the ability to achieve extremely high resolution imaging with minimum circuitry in the photo sensor array. This work relates the CCD121H Fairchild device to the fundamentals of CCDs and the representative technologies. Several failure modes are described, construction is analyzed and test results are reported. In addition, the relationship of the device reliability to packaging principles is analyzed and test data presented. Finally, a test program is defined for more general reliability evaluation of CCDs.

  12. Event-based Sensing for Space Situational Awareness

    NASA Astrophysics Data System (ADS)

    Cohen, G.; Afshar, S.; van Schaik, A.; Wabnitz, A.; Bessell, T.; Rutten, M.; Morreale, B.

    A revolutionary type of imaging device, known as a silicon retina or event-based sensor, has recently been developed and is gaining in popularity in the field of artificial vision systems. These devices are inspired by a biological retina and operate in a significantly different way to traditional CCD-based imaging sensors. While a CCD produces frames of pixel intensities, an event-based sensor produces a continuous stream of events, each of which is generated when a pixel detects a change in log light intensity. These pixels operate asynchronously and independently, producing an event-based output with high temporal resolution. There are also no fixed exposure times, allowing these devices to offer a very high dynamic range independently for each pixel. Additionally, these devices offer high-speed, low power operation and a sparse spatiotemporal output. As a consequence, the data from these sensors must be interpreted in a significantly different way to traditional imaging sensors and this paper explores the advantages this technology provides for space imaging. The applicability and capabilities of event-based sensors for SSA applications are demonstrated through telescope field trials. Trial results have confirmed that the devices are capable of observing resident space objects from LEO through to GEO orbital regimes. Significantly, observations of RSOs were made during both day-time and nighttime (terminator) conditions without modification to the camera or optics. The event based sensor’s ability to image stars and satellites during day-time hours offers a dramatic capability increase for terrestrial optical sensors. This paper shows the field testing and validation of two different architectures of event-based imaging sensors. An eventbased sensor’s asynchronous output has an intrinsically low data-rate. In addition to low-bandwidth communications requirements, the low weight, low-power and high-speed make them ideally suitable to meeting the demanding challenges required by space-based SSA systems. Results from these experiments and the systems developed highlight the applicability of event-based sensors to ground and space-based SSA tasks.

  13. Application and System Design of Elastomer Based Optofluidic Lenses

    NASA Astrophysics Data System (ADS)

    Savidis, Nickolaos

    Adaptive optic technology has revolutionized real time correction of wavefront aberrations. Optofluidic based applied optic devices have offered an opportunity to produce flexible refractive lenses in the correction of wavefronts. Fluidic lenses have superiority relative to their solid lens counterparts in their capabilities of producing tunable optical systems, that when synchronized, can produce real time variable systems with no moving parts. We have developed optofluidic fluidic lenses for applications of applied optical devices, as well as ophthalmic optic devices. The first half of this dissertation discusses the production of fluidic lenses as optical devices. In addition, the design and testing of various fluidic systems made with these components are evaluated. We begin with the creation of spherical or defocus singlet fluidic lenses. We then produced zoom optical systems with no moving parts by synchronizing combinations of these fluidic spherical lenses. The variable power zoom system incorporates two singlet fluidic lenses that are synchronized. The coupled device has no moving parts and has produced a magnification range of 0.1 x to 10 x or a 20 x magnification range. The chapter after fluidic zoom technology focuses on producing achromatic lens designs. We offer an analysis of a hybrid diffractive and refractive achromat that offers discrete achromatized variable focal lengths. In addition, we offer a design of a fully optofluidic based achromatic lens. By synchronizing the two membrane surfaces of the fluidic achromat we develop a design for a fluidic achromatic lens. The second half of this dissertation discusses the production of optofluidic technology in ophthalmic applications. We begin with an introduction to an optofluidic phoropter system. A fluidic phoropter is designed through the combination of a defocus lens with two cylindrical fluidic lenses that are orientated 45° relative to each other. Here we discuss the designs of the fluidic cylindrical lens coupled with a previously discussed defocus singlet lens. We then couple this optofluidic phoropter with relay optics and Shack-Hartmann wavefront sensing technology to produce an auto-phoropter device. The auto-phoropter system combines a refractometer designed Shack-Hartmann wavefront sensor with the compact refractive fluidic lens phoropter. This combination allows for the identification and control of ophthalmic cylinder, cylinder axis, as well as refractive error. The closed loop system of the fluidic phoropter with refractometer enables for the creation of our see-through auto-phoropter system. The design and testing of several generations of transmissive see-through auto-phoropter devices are presented in this section.

  14. 3D printed fluidics with embedded analytic functionality for automated reaction optimisation

    PubMed Central

    Capel, Andrew J; Wright, Andrew; Harding, Matthew J; Weaver, George W; Li, Yuqi; Harris, Russell A; Edmondson, Steve; Goodridge, Ruth D

    2017-01-01

    Additive manufacturing or ‘3D printing’ is being developed as a novel manufacturing process for the production of bespoke micro- and milliscale fluidic devices. When coupled with online monitoring and optimisation software, this offers an advanced, customised method for performing automated chemical synthesis. This paper reports the use of two additive manufacturing processes, stereolithography and selective laser melting, to create multifunctional fluidic devices with embedded reaction monitoring capability. The selectively laser melted parts are the first published examples of multifunctional 3D printed metal fluidic devices. These devices allow high temperature and pressure chemistry to be performed in solvent systems destructive to the majority of devices manufactured via stereolithography, polymer jetting and fused deposition modelling processes previously utilised for this application. These devices were integrated with commercially available flow chemistry, chromatographic and spectroscopic analysis equipment, allowing automated online and inline optimisation of the reaction medium. This set-up allowed the optimisation of two reactions, a ketone functional group interconversion and a fused polycyclic heterocycle formation, via spectroscopic and chromatographic analysis. PMID:28228852

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterczewski, L. A., E-mail: lukasz.sterczewski@pwr.edu.pl; Grzelczak, M. P.; Plinski, E. F.

    In this paper, we present an electronic circuit used to bias a photoconductive antenna that generates terahertz radiation. The working principles and the design process for the device are discussed in detail. The noise and shape of the wave measurements for a built device are considered. Furthermore, their impact on a terahertz pulse and its spectra is also examined. The proposed implementation is simple to build, robust and offers a real improvement over THz instrumentation due to the frequency tuning. Additionally, it provides for galvanic isolation and ESD protection.

  16. A quantitative analysis of optimal treatment capacity for perinatal asphyxia.

    PubMed

    Geva, Alon; Gray, James

    2012-01-01

    In centers electing to offer therapeutic hypothermia for treating hypoxic-ischemic encephalopathy (HIE), determining the optimal number of cooling devices is not straightforward. The authors used computer-based modeling to determine the level of service as a function of local HIE caseload and number of cooling devices available. The authors used discrete event simulation to create a model that varied the number of HIE cases and number of cooling devices available. Outcomes of interest were percentage of HIE-affected infants not cooled, number of infants not cooled, and percentage of time that all cooling devices were in use. With 1 cooling device, even the smallest perinatal center did not achieve a cooling rate of 99% of eligible infants. In contrast, 2 devices ensured 99% service in centers treating as many as 20 infants annually. In centers averaging no more than 1 HIE infant monthly, the addition of a third cooling device did not result in a substantial reduction in the number of infants who would not be cooled. Centers electing to offer therapeutic hypothermia with only a single cooling device are at significant risk of being unable to provide treatment to eligible infants, whereas 2 devices appear to suffice for most institutions treating as many as 20 annual HIE cases. Three devices would rarely be needed given current caseloads seen at individual institutions. The quantitative nature of this analysis allows decision makers to determine the number of devices necessary to ensure adequate availability of therapeutic hypothermia given the HIE caseload of a particular institution.

  17. First UK trial of Xenex PX-UV, an automated ultraviolet room decontamination device in a clinical haematology and bone marrow transplantation unit.

    PubMed

    Beal, A; Mahida, N; Staniforth, K; Vaughan, N; Clarke, M; Boswell, T

    2016-06-01

    There is growing interest in the use of no-touch automated room decontamination devices within healthcare settings. Xenex PX-UV is an automated room disinfection device using pulsed ultraviolet (UV) C radiation with a short cycle time. To investigate the microbiological efficacy of this device when deployed for terminal decontamination of isolation rooms within a clinical haematology unit. The device was deployed in isolation rooms in a clinical haematology unit. Contact plates were applied to common touch points to determine aerobic total colony counts (TCCs) and samples collected using Polywipe™ sponges for detection of vancomycin-resistant enterococci (VRE). The device was easy to transport, easy to use, and it disinfected rooms rapidly. There was a 76% reduction in the TCCs following manual cleaning, with an additional 14% reduction following UV disinfection, resulting in an overall reduction of 90% in TCCs. There was a 38% reduction in the number of sites where VRE was detected, from 26 of 80 sites following manual cleaning to 16 of 80 sites with additional UV disinfection. The Xenex PX-UV device can offer a simple and rapid additional decontamination step for terminal disinfection of patient rooms. However, the microbiological efficacy against VRE was somewhat limited. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Life in Special Schools in South Africa: Voices of Former Students

    ERIC Educational Resources Information Center

    McKinney, Emma Louise; Swartz, Leslie

    2016-01-01

    We describe educational experiences of people with disabilities who attended special schools in South Africa. We found significant differences in education between White and Black participants in terms of teaching quality, access to therapy and assistive devices, class sizes, subjects, and grades offered. Additional differences were noted between…

  19. Monitoring the health of power transformers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kirtley, J.L. Jr.; Hagman, W.H.; Lesieutre, B.C.

    This article reviews MIT`s model-based system which offers adaptive, intelligent surveillance of transformers, and summons attention to anomalous operation through paging devices. Failures of large power transformers are problematic for four reasons. Generally, large transformers are situated so that failures present operational problems to the system. In addition, large power transformers are encased in tanks of flammable and environmentally hazardous fluid. Failures are often accompanied by fire and/or spillage of this fluid. This presents hazards to people, other equipment and property, and the local environment. Finally, large power transformers are costly devices. There is a clear incentive for utilities tomore » keep track of the health of their power transformers. Massachusetts Institute of Technology (MIT) has developed an adaptive, intelligent, monitoring system for large power transformers. Four large transformers on the Boston Edison system are under continuous surveillance by this system, which can summon attention to anomalous operation through paging devices. The monitoring system offers two advantages over more traditional (not adaptive) methods of tracking transformer operation.« less

  20. The Application of a Cylindrical-spherical Floating Ring Bearing as a Device to Control Stability of Turbogenerators

    NASA Technical Reports Server (NTRS)

    Leung, P. S.; Craighead, I. A.; Wilkinson, T. S.

    1991-01-01

    The development of a new device to control stability of turbogenerators is described. The device comprises a floating ring installed between the journal and bearing housing of a fluid film bearing. The journal and the inner surface of the ring are cylindrical while the outer surface of the ring and bearing surface are spherical providing axial location of the ring and self-alignment of the bearing. The employment of this device would lead to a consistent machine performance. System stability may be controlled by changing a number of bearing and floating ring parameters. This device also offers an additional advantage of having a very low frictional characteristic. A feasibility study was carried out to investigate the suitability of the new device to turbogenerator applications. Both theoretical analysis and experimental observations were carried out. Initial results suggest that the new floating ring device is a competitive alternative to other conventional arrangements.

  1. Grid oscillators

    NASA Technical Reports Server (NTRS)

    Popovic, Zorana B.; Kim, Moonil; Rutledge, David B.

    1988-01-01

    Loading a two-dimensional grid with active devices offers a means of combining the power of solid-state oscillators in the microwave and millimeter-wave range. The grid structure allows a large number of negative resistance devices to be combined. This approach is attractive because the active devices do not require an external locking signal, and the combining is done in free space. In addition, the loaded grid is a planar structure amenable to monolithic integration. Measurements on a 25-MESFET grid at 9.7 GHz show power-combining and frequency-locking without an external locking signal, with an ERP of 37 W. Experimental far-field patterns agree with theoretical results obtained using reciprocity.

  2. DES the year in review: controversies.

    PubMed

    Garg, S; Bourantas, C; Serruys, P W

    2013-04-01

    Drug-eluting stents (DES) have transformed interventional cardiology over the past decade. Whilst their efficacy has rarely been called into question, there have been concerns over the safety of the early devices, which has prompted the development of new coronary stents. Many of these new devices have entered clinical practice, however questions remain as to whether they offer the improvements in clinical outcomes that were originally anticipated. In addition, there is a debate whether the reported high efficacy of these devices enables percutaneous coronary intervention (PCI) to be performed in patient and lesion sub-groups previous entirely the domain of the cardiac surgeon. This review paper addresses these outstanding questions.

  3. Field Performance versus Standard Test Condition Efficiency of Tandem Solar Cells and the Singular Case of Perovskites/Silicon Devices.

    PubMed

    Dupré, Olivier; Niesen, Bjoern; De Wolf, Stefaan; Ballif, Christophe

    2018-01-18

    Multijunction cells may offer a cost-effective route to boost the efficiency of industrial photovoltaics. For any technology to be deployed in the field, its performance under actual operating conditions is extremely important. In this perspective, we evaluate the impact of spectrum, light intensity, and module temperature variations on the efficiency of tandem devices with crystalline silicon bottom cells with a particular focus on perovskite top cells. We consider devices with different efficiencies and calculate their energy yields using field data from Denver. We find that annual losses due to differences between operating conditions and standard test conditions are similar for single-junction and four-terminal tandem devices. The additional loss for the two-terminal tandem configuration caused by current mismatch reduces its performance ratio by only 1.7% when an optimal top cell bandgap is used. Additionally, the unusual bandgap temperature dependence of perovskites is shown to have a positive, compensating effect on current mismatch.

  4. Design Review and Analysis | Water Power | NREL

    Science.gov Websites

    Design Review and Analysis Design Review and Analysis NREL is leveraging its 35 years of experience devices and components. As part of this effort, NREL researchers provide industry partners with design reviews and analyses. In addition to design reviews, NREL offers technical assistance to solve specific

  5. 78 FR 69018 - Improving the Resiliency of Mobile Wireless Communications Networks; Reliability and Continuity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-18

    ... offer their customers an increasing array of ``smartphones'' and data-centric devices, such as tablets... basis to provide service to their customers? 38. Additionally, the proposal would allow providers to... customers with comparable levels of service within that county? 40. Second, will consumers find this metric...

  6. Stable p-i-n FAPbBr 3 devices with improved efficiency using sputtered ZnO as electron transport layer [Stable p-i-n FAPbBr 3 devices with improved efficiency using sputtered inorganic electron transport layer

    DOE PAGES

    Subbiah, Anand S.; Agarwal, Sumanshu; Mahuli, Neha; ...

    2017-02-10

    Here, radio-frequency magnetron sputtering is demonstrated as an effective tool to deposit highly crystalline thin zinc oxide (ZnO) layer directly on perovskite absorber as an electron transport layer (ETL). As an absorber, formamidinium lead tribromide (FAPbBr 3) is fabricated through a modified single-step solution process using hydrogen bromide (HBr) as an additive resulting in complete surface coverage and highly crystalline material. A planar p-i-n device architecture with spin-coated poly-(3,4-ethylenedioxythiophene):poly-styrenesulfonic acid (PEDOT:PSS) as hole transport material (HTM) and sputtered ZnO as ETL results in a short circuit current density of 9.5 mA cm -2 and an open circuit potential of 1.19more » V. Numerical simulations are performed to validate the underlying loss mechanisms. The use of phenyl C 60 butyric acid methyl ester (PCBM) interface layer between FAPbBr 3 and sputter-coated ZnO offers shielding from potential plasma-related interface damage. The modified interface results in a better device efficiency of 8.3% with an open circuit potential of 1.35 V. Such devices offer better stability under continuous illumination under ambient conditions in comparison with the conventional organic ETL (PCBM)-based devices.« less

  7. Stable p-i-n FAPbBr 3 devices with improved efficiency using sputtered ZnO as electron transport layer [Stable p-i-n FAPbBr 3 devices with improved efficiency using sputtered inorganic electron transport layer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subbiah, Anand S.; Agarwal, Sumanshu; Mahuli, Neha

    Here, radio-frequency magnetron sputtering is demonstrated as an effective tool to deposit highly crystalline thin zinc oxide (ZnO) layer directly on perovskite absorber as an electron transport layer (ETL). As an absorber, formamidinium lead tribromide (FAPbBr 3) is fabricated through a modified single-step solution process using hydrogen bromide (HBr) as an additive resulting in complete surface coverage and highly crystalline material. A planar p-i-n device architecture with spin-coated poly-(3,4-ethylenedioxythiophene):poly-styrenesulfonic acid (PEDOT:PSS) as hole transport material (HTM) and sputtered ZnO as ETL results in a short circuit current density of 9.5 mA cm -2 and an open circuit potential of 1.19more » V. Numerical simulations are performed to validate the underlying loss mechanisms. The use of phenyl C 60 butyric acid methyl ester (PCBM) interface layer between FAPbBr 3 and sputter-coated ZnO offers shielding from potential plasma-related interface damage. The modified interface results in a better device efficiency of 8.3% with an open circuit potential of 1.35 V. Such devices offer better stability under continuous illumination under ambient conditions in comparison with the conventional organic ETL (PCBM)-based devices.« less

  8. Nanomagnet Logic: Architectures, design, and benchmarking

    NASA Astrophysics Data System (ADS)

    Kurtz, Steven J.

    Nanomagnet Logic (NML) is an emerging technology being studied as a possible replacement or supplementary device for Complimentary Metal-Oxide-Semiconductor (CMOS) Field-Effect Transistors (FET) by the year 2020. NML devices offer numerous potential advantages including: low energy operation, steady state non-volatility, radiation hardness and a clear path to fabrication and integration with CMOS. However, maintaining both low-energy operation and non-volatility while scaling from the device to the architectural level is non-trivial as (i) nearest neighbor interactions within NML circuits complicate the modeling of ensemble nanomagnet behavior and (ii) the energy intensive clock structures required for re-evaluation and NML's relatively high latency challenge its ability to offer system-level performance wins against other emerging nanotechnologies. Thus, further research efforts are required to model more complex circuits while also identifying circuit design techniques that balance low-energy operation with steady state non-volatility. In addition, further work is needed to design and model low-power on-chip clocks while simultaneously identifying application spaces where NML systems (including clock overhead) offer sufficient energy savings to merit their inclusion in future processors. This dissertation presents research advancing the understanding and modeling of NML at all levels including devices, circuits, and line clock structures while also benchmarking NML against both scaled CMOS and tunneling FETs (TFET) devices. This is accomplished through the development of design tools and methodologies for (i) quantifying both energy and stability in NML circuits and (ii) evaluating line-clocked NML system performance. The application of these newly developed tools improves the understanding of ideal design criteria (i.e., magnet size, clock wire geometry, etc.) for NML architectures. Finally, the system-level performance evaluation tool offers the ability to project what advancements are required for NML to realize performance improvements over scaled-CMOS hardware equivalents at the functional unit and/or application-level.

  9. Optical Studies of the Quantum Confined Stark Effect in ALUMINUM(0.3) GALLIUM(0.7) Arsenide/gallium Arsenide Coupled Double Quantum Wells

    NASA Astrophysics Data System (ADS)

    Kuroda, Roger Tokuichi

    1992-01-01

    The development of advanced epitaxical growth techniques such as molecular beam epitaxy has led to growth of high quality III-V layers with monolayer control in thickness. This permits design of new and novel heterointerface based electronic, optical and opto-electronic devices which exploit the new and tailorable electronic states in quantum wells. One such property is the Quantum Confined Stark Effect (QCSE) which, in uncoupled multiple quantum wells (MQW), has been used for the self-electro-optic effect device(SEED). Guided by a phenomenological model of the complex dielectric function for the Coupled Double Quantum Well (CDQW), we show results for the QCSE in CDQW show underlying physics differs from the uncoupled MQW in that symmetry forbidden transitions under flat band conditions become allowed under non-flat band conditions. The transfer of oscillator strength from symmetry allowed to the symmetry forbidden transitions offers potential for application as spatial light modulator (SLM). We show the CDQW lowest exciton peak Stark shifts twice as fast as the SQW with equivalent well width, which offers the SLM device a lower operating voltage than SQW. In addition we show the CDQW absorption band edge can blue shift with increasing electric field, which offers other potential for SLM. From transmission measurements, we verify these predictions and compare them with the phenomenological model. The optical device figure of merit Deltaalpha/alpha of the CDQW is comparable with the "best" SQW, but at lower electric field. From photocurrent measurements, we find that the calculated and measured Stark shifts agree. In addition, we extract a Deltaalpha/ alpha from photocurrent which agree with transmission measurements. From electroreflectance measurements, we calculated the aluminum concentration, and the built in electric field from the Franz-Keldysh oscillations due to the Al_{0.3}Ga _{0.7}As barrier regions in the CDQW. (Copies available exclusively from Micrographics Department, Doheny Library, USC, Los Angeles, CA 90089 -0182.).

  10. Graphene-Based Three-Dimensional Capacitive Touch Sensor for Wearable Electronics.

    PubMed

    Kang, Minpyo; Kim, Jejung; Jang, Bongkyun; Chae, Youngcheol; Kim, Jae-Hyun; Ahn, Jong-Hyun

    2017-08-22

    The development of input device technology in a conformal and stretchable format is important for the advancement of various wearable electronics. Herein, we report a capacitive touch sensor with good sensing capabilities in both contact and noncontact modes, enabled by the use of graphene and a thin device geometry. This device can be integrated with highly deformable areas of the human body, such as the forearms and palms. This touch sensor detects multiple touch signals in acute recordings and recognizes the distance and shape of the approaching objects before direct contact is made. This technology offers a convenient and immersive human-machine interface and additional potential utility as a multifunctional sensor for emerging wearable electronics and robotics.

  11. Mobile computing in critical care.

    PubMed

    Lapinsky, Stephen E

    2007-03-01

    Handheld computing devices are increasingly used by health care workers, and offer a mobile platform for point-of-care information access. Improved technology, with larger memory capacity, higher screen resolution, faster processors, and wireless connectivity has broadened the potential roles for these devices in critical care. In addition to the personal information management functions, handheld computers have been used to access reference information, management guidelines and pharmacopoeias as well as to track the educational experience of trainees. They can act as an interface with a clinical information system, providing rapid access to patient information. Despite their popularity, these devices have limitations related to their small size, and acceptance by physicians has not been uniform. In the critical care environment, the risk of transmitting microorganisms by such a portable device should always be considered.

  12. Paper as a platform for sensing applications and other devices: a review.

    PubMed

    Mahadeva, Suresha K; Walus, Konrad; Stoeber, Boris

    2015-04-29

    Paper is a ubiquitous material that has various applications in day to day life. A sheet of paper is produced by pressing moist wood cellulose fibers together. Paper offers unique properties: paper allows passive liquid transport, it is compatible with many chemical and biochemical moieties, it exhibits piezoelectricity, and it is biodegradable. Hence, paper is an attractive low-cost functional material for sensing devices. In recent years, researchers in the field of science and engineering have witnessed an exponential growth in the number of research contributions that focus on the development of cost-effective and scalable fabrication methods and new applications of paper-based devices. In this review article, we highlight recent advances in the development of paper-based sensing devices in the areas of electronics, energy storage, strain sensing, microfluidic devices, and biosensing, including piezoelectric paper. Additionally, this review includes current limitations of paper-based sensing devices and points out issues that have limited the commercialization of some of the paper-based sensing devices.

  13. Emerging Carbon and Post-Carbon Nanomaterial Inks for Printed Electronics.

    PubMed

    Secor, Ethan B; Hersam, Mark C

    2015-02-19

    Carbon and post-carbon nanomaterials present desirable electrical, optical, chemical, and mechanical attributes for printed electronics, offering low-cost, large-area functionality on flexible substrates. In this Perspective, recent developments in carbon nanomaterial inks are highlighted. Monodisperse semiconducting single-walled carbon nanotubes compatible with inkjet and aerosol jet printing are ideal channels for thin-film transistors, while inkjet, gravure, and screen-printable graphene-based inks are better-suited for electrodes and interconnects. Despite the high performance achieved in prototype devices, additional effort is required to address materials integration issues encountered in more complex systems. In this regard, post-carbon nanomaterial inks (e.g., electrically insulating boron nitride and optically active transition-metal dichalcogenides) present promising opportunities. Finally, emerging work to extend these nanomaterial inks to three-dimensional printing provides a path toward nonplanar devices. Overall, the superlative properties of these materials, coupled with versatile assembly by printing techniques, offer a powerful platform for next-generation printed electronics.

  14. Bioresorbable silicon electronics for transient spatiotemporal mapping of electrical activity from the cerebral cortex.

    PubMed

    Yu, Ki Jun; Kuzum, Duygu; Hwang, Suk-Won; Kim, Bong Hoon; Juul, Halvor; Kim, Nam Heon; Won, Sang Min; Chiang, Ken; Trumpis, Michael; Richardson, Andrew G; Cheng, Huanyu; Fang, Hui; Thomson, Marissa; Bink, Hank; Talos, Delia; Seo, Kyung Jin; Lee, Hee Nam; Kang, Seung-Kyun; Kim, Jae-Hwan; Lee, Jung Yup; Huang, Younggang; Jensen, Frances E; Dichter, Marc A; Lucas, Timothy H; Viventi, Jonathan; Litt, Brian; Rogers, John A

    2016-07-01

    Bioresorbable silicon electronics technology offers unprecedented opportunities to deploy advanced implantable monitoring systems that eliminate risks, cost and discomfort associated with surgical extraction. Applications include postoperative monitoring and transient physiologic recording after percutaneous or minimally invasive placement of vascular, cardiac, orthopaedic, neural or other devices. We present an embodiment of these materials in both passive and actively addressed arrays of bioresorbable silicon electrodes with multiplexing capabilities, which record in vivo electrophysiological signals from the cortical surface and the subgaleal space. The devices detect normal physiologic and epileptiform activity, both in acute and chronic recordings. Comparative studies show sensor performance comparable to standard clinical systems and reduced tissue reactivity relative to conventional clinical electrocorticography (ECoG) electrodes. This technology offers general applicability in neural interfaces, with additional potential utility in treatment of disorders where transient monitoring and modulation of physiologic function, implant integrity and tissue recovery or regeneration are required.

  15. ContextProvider: Context awareness for medical monitoring applications.

    PubMed

    Mitchell, Michael; Meyers, Christopher; Wang, An-I Andy; Tyson, Gary

    2011-01-01

    Smartphones are sensor-rich and Internet-enabled. With their on-board sensors, web services, social media, and external biosensors, smartphones can provide contextual information about the device, user, and environment, thereby enabling the creation of rich, biologically driven applications. We introduce ContextProvider, a framework that offers a unified, query-able interface to contextual data on the device. Unlike other context-based frameworks, ContextProvider offers interactive user feedback, self-adaptive sensor polling, and minimal reliance on third-party infrastructure. ContextProvider also allows for rapid development of new context and bio-aware applications. Evaluation of ContextProvider shows the incorporation of an additional monitoring sensor into the framework with fewer than 100 lines of Java code. With adaptive sensor monitoring, power consumption per sensor can be reduced down to 1% overhead. Finally, through the use of context, accuracy of data interpretation can be improved by up to 80%.

  16. A generic interface to reduce the efficiency-stability-cost gap of perovskite solar cells

    NASA Astrophysics Data System (ADS)

    Hou, Yi; Du, Xiaoyan; Scheiner, Simon; McMeekin, David P.; Wang, Zhiping; Li, Ning; Killian, Manuela S.; Chen, Haiwei; Richter, Moses; Levchuk, Ievgen; Schrenker, Nadine; Spiecker, Erdmann; Stubhan, Tobias; Luechinger, Norman A.; Hirsch, Andreas; Schmuki, Patrik; Steinrück, Hans-Peter; Fink, Rainer H.; Halik, Marcus; Snaith, Henry J.; Brabec, Christoph J.

    2017-12-01

    A major bottleneck delaying the further commercialization of thin-film solar cells based on hybrid organohalide lead perovskites is interface loss in state-of-the-art devices. We present a generic interface architecture that combines solution-processed, reliable, and cost-efficient hole-transporting materials without compromising efficiency, stability, or scalability of perovskite solar cells. Tantalum-doped tungsten oxide (Ta-WOx)/conjugated polymer multilayers offer a surprisingly small interface barrier and form quasi-ohmic contacts universally with various scalable conjugated polymers. In a simple device with regular planar architecture and a self-assembled monolayer, Ta-WOx-doped interface-based perovskite solar cells achieve maximum efficiencies of 21.2% and offer more than 1000 hours of light stability. By eliminating additional ionic dopants, these findings open up the entire class of organics as scalable hole-transporting materials for perovskite solar cells.

  17. Additive Manufacturing: Unlocking the Evolution of Energy Materials

    PubMed Central

    Zhakeyev, Adilet; Wang, Panfeng; Shu, Wenmiao; Wang, Huizhi

    2017-01-01

    Abstract The global energy infrastructure is undergoing a drastic transformation towards renewable energy, posing huge challenges on the energy materials research, development and manufacturing. Additive manufacturing has shown its promise to change the way how future energy system can be designed and delivered. It offers capability in manufacturing complex 3D structures, with near‐complete design freedom and high sustainability due to minimal use of materials and toxic chemicals. Recent literatures have reported that additive manufacturing could unlock the evolution of energy materials and chemistries with unprecedented performance in the way that could never be achieved by conventional manufacturing techniques. This comprehensive review will fill the gap in communicating on recent breakthroughs in additive manufacturing for energy material and device applications. It will underpin the discoveries on what 3D functional energy structures can be created without design constraints, which bespoke energy materials could be additively manufactured with customised solutions, and how the additively manufactured devices could be integrated into energy systems. This review will also highlight emerging and important applications in energy additive manufacturing, including fuel cells, batteries, hydrogen, solar cell as well as carbon capture and storage. PMID:29051861

  18. Additive Manufacturing: Unlocking the Evolution of Energy Materials.

    PubMed

    Zhakeyev, Adilet; Wang, Panfeng; Zhang, Li; Shu, Wenmiao; Wang, Huizhi; Xuan, Jin

    2017-10-01

    The global energy infrastructure is undergoing a drastic transformation towards renewable energy, posing huge challenges on the energy materials research, development and manufacturing. Additive manufacturing has shown its promise to change the way how future energy system can be designed and delivered. It offers capability in manufacturing complex 3D structures, with near-complete design freedom and high sustainability due to minimal use of materials and toxic chemicals. Recent literatures have reported that additive manufacturing could unlock the evolution of energy materials and chemistries with unprecedented performance in the way that could never be achieved by conventional manufacturing techniques. This comprehensive review will fill the gap in communicating on recent breakthroughs in additive manufacturing for energy material and device applications. It will underpin the discoveries on what 3D functional energy structures can be created without design constraints, which bespoke energy materials could be additively manufactured with customised solutions, and how the additively manufactured devices could be integrated into energy systems. This review will also highlight emerging and important applications in energy additive manufacturing, including fuel cells, batteries, hydrogen, solar cell as well as carbon capture and storage.

  19. Ultrahigh Performance C60 Nanorod Large Area Flexible Photoconductor Devices via Ultralow Organic and Inorganic Photodoping

    PubMed Central

    Saran, Rinku; Stolojan, Vlad; Curry, Richard J.

    2014-01-01

    One dimensional single-crystal nanorods of C60 possess unique optoelectronic properties including high electron mobility, high photosensitivity and an excellent electron accepting nature. In addition, their rapid large scale synthesis at room temperature makes these organic semiconducting nanorods highly attractive for advanced optoelectronic device applications. Here, we report low-cost large-area flexible photoconductor devices fabricated using C60 nanorods. We demonstrate that the photosensitivity of the C60 nanorods can be enhanced ~400-fold via an ultralow photodoping mechanism. The photodoped devices offer broadband UV-vis-NIR spectral tuneability, exhibit a detectivitiy >109 Jones, an external quantum efficiency of ~100%, a linear dynamic range of 80 dB, a rise time 60 µs and the ability to measure ac signals up to ~250 kHz. These figures of merit combined are among the highest reported for one dimensional organic and inorganic large-area planar photoconductors and are competitive with commercially available inorganic photoconductors and photoconductive cells. With the additional processing benefits providing compatibility with large-area flexible platforms, these devices represent significant advances and make C60 nanorods a promising candidate for advanced photodetector technologies. PMID:24853479

  20. Insulin pumps and insulin quality--requirements and problems.

    PubMed

    Brange, J; Havelund, S

    1983-01-01

    In developing insulin solution suitable for delivery devices the chemical and biological stability, as well as the physical stability, must be taken into consideration. Addition of certain mono- and disaccharides increases the physical stability of neutral insulin solutions, but concurrently the chemical and biological stability decrease to an unacceptable degree. Addition of Ca-ions in low concentrations offers a physiologically acceptable method for stabilizing neutral insulin solutions against heat precipitation without affecting the quality, including the chemical and biological stability.

  1. Design and development of wafer-level near-infrared micro-camera

    NASA Astrophysics Data System (ADS)

    Zeller, John W.; Rouse, Caitlin; Efstathiadis, Harry; Haldar, Pradeep; Dhar, Nibir K.; Lewis, Jay S.; Wijewarnasuriya, Priyalal; Puri, Yash R.; Sood, Ashok K.

    2015-08-01

    SiGe offers a low-cost alternative to conventional infrared sensor material systems such as InGaAs, InSb, and HgCdTe for developing near-infrared (NIR) photodetector devices that do not require cooling and can offer high bandwidths and responsivities. As a result of the significant difference in thermal expansion coefficients between germanium and silicon, tensile strain incorporated into Ge epitaxial layers deposited on Si utilizing specialized growth processes can extend the operational range of detection to 1600 nm and longer wavelengths. We have fabricated SiGe based PIN detector devices on 300 mm diameter Si wafers in order to take advantage of high throughput, large-area complementary metal-oxide semiconductor (CMOS) technology. This device fabrication process involves low temperature epitaxial deposition of Ge to form a thin p+ seed/buffer layer, followed by higher temperature deposition of a thicker Ge intrinsic layer. An n+-Ge layer formed by ion implantation of phosphorus, passivating oxide cap, and then top copper contacts complete the PIN photodetector design. Various techniques including transmission electron microscopy (TEM) and secondary ion mass spectrometry (SIMS) have been employed to characterize the material and structural properties of the epitaxial growth and fabricated detector devices. In addition, electrical characterization was performed to compare the I-V dark current vs. photocurrent response as well as the time and wavelength varying photoresponse properties of the fabricated devices, results of which are likewise presented.

  2. Additive Biotech-Chances, challenges, and recent applications of additive manufacturing technologies in biotechnology.

    PubMed

    Krujatz, Felix; Lode, Anja; Seidel, Julia; Bley, Thomas; Gelinsky, Michael; Steingroewer, Juliane

    2017-10-25

    The diversity and complexity of biotechnological applications are constantly increasing, with ever expanding ranges of production hosts, cultivation conditions and measurement tasks. Consequently, many analytical and cultivation systems for biotechnology and bioprocess engineering, such as microfluidic devices or bioreactors, are tailor-made to precisely satisfy the requirements of specific measurements or cultivation tasks. Additive manufacturing (AM) technologies offer the possibility of fabricating tailor-made 3D laboratory equipment directly from CAD designs with previously inaccessible levels of freedom in terms of structural complexity. This review discusses the historical background of these technologies, their most promising current implementations and the associated workflows, fabrication processes and material specifications, together with some of the major challenges associated with using AM in biotechnology/bioprocess engineering. To illustrate the great potential of AM, selected examples in microfluidic devices, 3D-bioprinting/biofabrication and bioprocess engineering are highlighted. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Microfluidic cell sorting: a review of the advances in the separation of cells from debulking to rare cell isolation.

    PubMed

    Shields, C Wyatt; Reyes, Catherine D; López, Gabriel P

    2015-03-07

    Accurate and high throughput cell sorting is a critical enabling technology in molecular and cellular biology, biotechnology, and medicine. While conventional methods can provide high efficiency sorting in short timescales, advances in microfluidics have enabled the realization of miniaturized devices offering similar capabilities that exploit a variety of physical principles. We classify these technologies as either active or passive. Active systems generally use external fields (e.g., acoustic, electric, magnetic, and optical) to impose forces to displace cells for sorting, whereas passive systems use inertial forces, filters, and adhesion mechanisms to purify cell populations. Cell sorting on microchips provides numerous advantages over conventional methods by reducing the size of necessary equipment, eliminating potentially biohazardous aerosols, and simplifying the complex protocols commonly associated with cell sorting. Additionally, microchip devices are well suited for parallelization, enabling complete lab-on-a-chip devices for cellular isolation, analysis, and experimental processing. In this review, we examine the breadth of microfluidic cell sorting technologies, while focusing on those that offer the greatest potential for translation into clinical and industrial practice and that offer multiple, useful functions. We organize these sorting technologies by the type of cell preparation required (i.e., fluorescent label-based sorting, bead-based sorting, and label-free sorting) as well as by the physical principles underlying each sorting mechanism.

  4. Microfluidic Cell Sorting: A Review of the Advances in the Separation of Cells from Debulking to Rare Cell Isolation

    PubMed Central

    Shields, C. Wyatt; Reyes, Catherine D.; López, Gabriel P.

    2015-01-01

    Accurate and high throughput cell sorting is a critical enabling technology in molecular and cellular biology, biotechnology, and medicine. While conventional methods can provide high efficiency sorting in short timescales, advances in microfluidics have enabled the realization of miniaturized devices offering similar capabilities that exploit a variety of physical principles. We classify these technologies as either active or passive. Active systems generally use external fields (e.g., acoustic, electric, magnetic, and optical) to impose forces to displace cells for sorting, whereas passive systems use inertial forces, filters, and adhesion mechanisms to purify cell populations. Cell sorting on microchips provides numerous advantages over conventional methods by reducing the size of necessary equipment, eliminating potentially biohazardous aerosols, and simplifying the complex protocols commonly associated with cell sorting. Additionally, microchip devices are well suited for parallelization, enabling complete lab-on-a-chip devices for cellular isolation, analysis, and experimental processing. In this review, we examine the breadth of microfluidic cell sorting technologies, while focusing on those that offer the greatest potential for translation into clinical and industrial practice and that offer multiple, useful functions. We organize these sorting technologies by the type of cell preparation required (i.e., fluorescent label-based sorting, bead-based sorting, and label-free sorting) as well as by the physical principles underlying each sorting mechanism. PMID:25598308

  5. Monolithically integrated Si gate-controlled light-emitting device: science and properties

    NASA Astrophysics Data System (ADS)

    Xu, Kaikai

    2018-02-01

    The motivation of this study is to develop a p-n junction based light emitting device, in which the light emission is conventionally realized using reverse current driving, by voltage driving. By introducing an additional terminal of insulated gate for voltage driving, a novel three-terminal Si light emitting device is described where both the light intensity and spatial light pattern of the device are controlled by the gate voltage. The proposed light emitting device employs injection-enhanced Si in avalanche mode where electric field confinement occurs in the corner of a reverse-biased p+n junction. It is found that, depending on the bias conditions, the light intensity is either a linear or a quadratic function of the applied gate voltage or the reverse-bias. Since the light emission is based on the avalanching mode, the Si light emitting device offers the potential for very large scale integration-compatible light emitters for inter- or intra-chip signal transmission and contactless functional testing of wafers.

  6. Single walled carbon nanotube-based stochastic resonance device with molecular self-noise source

    NASA Astrophysics Data System (ADS)

    Fujii, Hayato; Setiadi, Agung; Kuwahara, Yuji; Akai-Kasaya, Megumi

    2017-09-01

    Stochastic resonance (SR) is an intrinsic noise usage system for small-signal sensing found in various living creatures. The noise-enhanced signal transmission and detection system, which is probabilistic but consumes low power, has not been used in modern electronics. We demonstrated SR in a summing network based on a single-walled carbon nanotube (SWNT) device that detects small subthreshold signals with very low current flow. The nonlinear current-voltage characteristics of this SWNT device, which incorporated Cr electrodes, were used as the threshold level of signal detection. The adsorption of redox-active polyoxometalate molecules on SWNTs generated additional noise, which was utilized as a self-noise source. To form a summing network SR device, a large number of SWNTs were aligned parallel to each other between the electrodes, which increased the signal detection ability. The functional capabilities of the present small-size summing network SR device, which rely on dense nanomaterials and exploit intrinsic spontaneous noise at room temperature, offer a glimpse of future bio-inspired electronic devices.

  7. Microchip-based electrochemical detection using a 3-D printed wall-jet electrode device.

    PubMed

    Munshi, Akash S; Martin, R Scott

    2016-02-07

    Three dimensional (3-D) printing technology has evolved dramatically in the last few years, offering the capability of printing objects with a variety of materials. Printing microfluidic devices using this technology offers various advantages such as ease and uniformity of fabrication, file sharing between laboratories, and increased device-to-device reproducibility. One unique aspect of this technology, when used with electrochemical detection, is the ability to produce a microfluidic device as one unit while also allowing the reuse of the device and electrode for multiple analyses. Here we present an alternate electrode configuration for microfluidic devices, a wall-jet electrode (WJE) approach, created by 3-D printing. Using microchip-based flow injection analysis, we compared the WJE design with the conventionally used thin-layer electrode (TLE) design. It was found that the optimized WJE system enhances analytical performance (as compared to the TLE design), with improvements in sensitivity and the limit of detection. Experiments were conducted using two working electrodes - 500 μm platinum and 1 mm glassy carbon. Using the 500 μm platinum electrode the calibration sensitivity was 16 times higher for the WJE device (as compared to the TLE design). In addition, use of the 1 mm glassy carbon electrode led to limit of detection of 500 nM for catechol, as compared to 6 μM for the TLE device. Finally, to demonstrate the versatility and applicability of the 3-D printed WJE approach, the device was used as an inexpensive electrochemical detector for HPLC. The number of theoretical plates was comparable to the use of commercially available UV and MS detectors, with the WJE device being inexpensive to utilize. These results show that 3-D-printing can be a powerful tool to fabricate reusable and integrated microfluidic detectors in configurations that are not easily achieved with more traditional lithographic methods.

  8. Resistive switching memory devices composed of binary transition metal oxides using sol-gel chemistry.

    PubMed

    Lee, Chanwoo; Kim, Inpyo; Choi, Wonsup; Shin, Hyunjung; Cho, Jinhan

    2009-04-21

    We describe a novel and versatile approach for preparing resistive switching memory devices based on binary transition metal oxides (TMOs). Titanium isopropoxide (TIPP) was spin-coated onto platinum (Pt)-coated silicon substrates using a sol-gel process. The sol-gel-derived layer was converted into a TiO2 film by thermal annealing. A top electrode (Ag electrode) was then coated onto the TiO2 films to complete device fabrication. When an external bias was applied to the devices, a switching phenomenon independent of the voltage polarity (i.e., unipolar switching) was observed at low operating voltages (about 0.6 VRESET and 1.4 VSET). In addition, it was confirmed that the electrical properties (i.e., retention time, cycling test and switching speed) of the sol-gel-derived devices were comparable to those of vacuum deposited devices. This approach can be extended to a variety of binary TMOs such as niobium oxides. The reported approach offers new opportunities for preparing the binary TMO-based resistive switching memory devices allowing a facile solution processing.

  9. Stable Radical Materials for Energy Applications.

    PubMed

    Wilcox, Daniel A; Agarkar, Varad; Mukherjee, Sanjoy; Boudouris, Bryan W

    2018-06-07

    Although less studied than their closed-shell counterparts, materials containing stable open-shell chemistries have played a key role in many energy storage and energy conversion devices. In particular, the oxidation-reduction (redox) properties of these stable radicals have made them a substantial contributor to the progress of organic batteries. Moreover, the use of radical-based materials in photovoltaic devices and thermoelectric systems has allowed for these emerging molecules to have impacts in the energy conversion realm. Additionally, the unique doublet states of radical-based materials provide access to otherwise inaccessible spin states in optoelectronic devices, offering many new opportunities for efficient usage of energy in light-emitting devices. Here, we review the current state of the art regarding the molecular design, synthesis, and application of stable radicals in these energy-related applications. Finally, we point to fundamental and applied arenas of future promise for these designer open-shell molecules, which have only just begun to be evaluated in full.

  10. Nanocoaxes for Optical and Electronic Devices

    PubMed Central

    Rizal, Binod; Merlo, Juan M.; Burns, Michael J.; Chiles, Thomas C.; Naughton, Michael J.

    2014-01-01

    The evolution of micro/nanoelectronics technology, including the shrinking of devices and integrated circuit components, has included the miniaturization of linear and coaxial structures to micro/nanoscale dimensions. This reduction in the size of coaxial structures may offer advantages to existing technologies and benefit the exploration and development of new technologies. The reduction in the size of coaxial structures has been realized with various permutations between metals, semiconductors and dielectrics for the core, shield, and annulus. This review will focus on fabrication schemes of arrays of metal – nonmetal – metal nanocoax structures using non-template and template methods, followed by possible applications. The performance and scientific advantages associated with nanocoax-based optical devices including waveguides, negative refractive index materials, light emitting diodes, and photovoltaics are presented. In addition, benefits and challenges that accrue from the application of novel nanocoax structures in energy storage, electronic and sensing devices are summarized. PMID:25279400

  11. Muscle activity of leg muscles during unipedal stance on therapy devices with different stability properties.

    PubMed

    Wolburg, Thomas; Rapp, Walter; Rieger, Jochen; Horstmann, Thomas

    2016-01-01

    To test the hypotheses that less stable therapy devices require greater muscle activity and that lower leg muscles will have greater increases in muscle activity with less stable therapy devices than upper leg muscles. Cross-sectional laboratory study. Laboratory setting. Twenty-five healthy subjects. Electromyographic activity of four lower (gastrocnemius medialis, soleus, tibialis anterior, peroneus longus) and four upper leg muscles (vastus medialis and lateralis, biceps femoris, semitendinosus) during unipedal quiet barefoot stance on the dominant leg on a flat rigid surface and on five therapy devices with varying stability properties. Muscle activity during unipedal stance differed significantly between therapy devices (P < 0.001). The order from lowest to highest relative muscle activity matched the order from most to least stable therapy device. There was no significant interaction between muscle location (lower versus upper leg) and therapy device (P = 0.985). Magnitudes of additional relative muscle activity for the respective therapy devices differed substantially among lower extremity muscles. The therapy devices offer a progressive increase in training intensity, and thus may be useful for incremental training programs in physiotherapeutic practice and sports training programs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The development of an upper limb stroke rehabilitation robot: identification of clinical practices and design requirements through a survey of therapists.

    PubMed

    Lu, Elaine C; Wang, Rosalie H; Hebert, Debbie; Boger, Jennifer; Galea, Mary P; Mihailidis, Alex

    2011-01-01

    PURPOSE. Timely and adequate rehabilitation after a stroke is crucial to maximising recovery. A way of increasing treatment access could be through robots, which would aid therapists in providing post-stroke rehabilitation. This research sought to discover the needs and preferences of therapists with respect to a robot that focuses on upper limb rehabilitation. Understanding requirements for devices could help to increase integration into clinical practice. METHODS. An international online survey was distributed through professional organisations and e-mail list services to therapists. The survey contained 85 items covering topics such as therapist background and treatment approach, rehabilitation aims and robotic rehabilitation device attributes. RESULTS. Data were analysed for 233 respondents, most of whom were physiotherapists and occupational therapists from Australia, Canada and USA. Top attributes included: facilitating a variety of arm movements, being usable while seated, giving biofeedback to clients, having virtual activities specific to daily living, being useful in-home and having resistance adjustable to client needs. In addition, the device should cost under 6000 USD. CONCLUSIONS. Findings from this survey provide guidance for technology developers regarding therapists' specifications for a robotic device for upper limb rehabilitation. In addition, findings offer a better understanding of how acceptance of such devices may be facilitated.

  13. Nanoionics-Based Switches for Radio-Frequency Applications

    NASA Technical Reports Server (NTRS)

    Nessel, James; Lee, Richard

    2010-01-01

    Nanoionics-based devices have shown promise as alternatives to microelectromechanical systems (MEMS) and semiconductor diode devices for switching radio-frequency (RF) signals in diverse systems. Examples of systems that utilize RF switches include phase shifters for electronically steerable phased-array antennas, multiplexers, cellular telephones and other radio transceivers, and other portable electronic devices. Semiconductor diode switches can operate at low potentials (about 1 to 3 V) and high speeds (switching times of the order of nanoseconds) but are characterized by significant insertion loss, high DC power consumption, low isolation, and generation of third-order harmonics and intermodulation distortion (IMD). MEMS-based switches feature low insertion loss (of the order of 0.2 dB), low DC power consumption (picowatts), high isolation (>30 dB), and low IMD, but contain moving parts, are not highly reliable, and must be operated at high actuation potentials (20 to 60 V) generated and applied by use of complex circuitry. In addition, fabrication of MEMS is complex, involving many processing steps. Nanoionics-based switches offer the superior RF performance and low power consumption of MEMS switches, without need for the high potentials and complex circuitry necessary for operation of MEMS switches. At the same time, nanoionics-based switches offer the high switching speed of semiconductor devices. Also, like semiconductor devices, nanoionics-based switches can be fabricated relatively inexpensively by use of conventional integrated-circuit fabrication techniques. More over, nanoionics-based switches have simple planar structures that can easily be integrated into RF power-distribution circuits.

  14. An Evidence-Based Approach To Exercise Prescriptions on ISS

    NASA Technical Reports Server (NTRS)

    Ploutz-Snyder, Lori

    2009-01-01

    This presentation describes current exercise countermeasures and exercise equipment for astronauts onboard the ISS. Additionally, a strategy for evaluating evidence supporting spaceflight exercise is described and a new exercise prescription is proposed. The current exercise regimen is not fully effective as the ISS exercise hardware does not allow for sufficient exercise intensity, the exercise prescription is adequate and crew members are noncompliant with the prescription. New ISS hardware is proposed, Advanced Resistance Exercise Device (ARED), which allows additional exercises, is instrumented for data acquisition and offers improved loading. The new T2 hardware offers a better harness and subject loading system, is instrumented to allow ground reaction force data, and offers improved speed. A strategy for developing a spaceflight exercise prescription is described and involves identifying exercise training programs that have been shown to maximize adaptive benefits of people exercising in both 0 and 1 g environments. Exercise intensity emerged as an important factor in maintaining physiologic adaptations in the spaceflight environment and interval training is suggested. New ISS exercise hardware should allow for exercise at intensities high enough to elicit adaptive responses. Additionally, new exercise prescriptions should incorporate higher intensity exercises and seek to optimize intensity, duration and frequency for greater efficiency.

  15. Design for Additive Bio-Manufacturing: From Patient-Specific Medical Devices to Rationally Designed Meta-Biomaterials.

    PubMed

    Zadpoor, Amir A

    2017-07-25

    Recent advances in additive manufacturing (AM) techniques in terms of accuracy, reliability, the range of processable materials, and commercial availability have made them promising candidates for production of functional parts including those used in the biomedical industry. The complexity-for-free feature offered by AM means that very complex designs become feasible to manufacture, while batch-size-indifference enables fabrication of fully patient-specific medical devices. Design for AM (DfAM) approaches aim to fully utilize those features for development of medical devices with substantially enhanced performance and biomaterials with unprecedented combinations of favorable properties that originate from complex geometrical designs at the micro-scale. This paper reviews the most important approaches in DfAM particularly those applicable to additive bio-manufacturing including image-based design pipelines, parametric and non-parametric designs, metamaterials, rational and computationally enabled design, topology optimization, and bio-inspired design. Areas with limited research have been identified and suggestions have been made for future research. The paper concludes with a brief discussion on the practical aspects of DfAM and the potential of combining AM with subtractive and formative manufacturing processes in so-called hybrid manufacturing processes.

  16. Design for Additive Bio-Manufacturing: From Patient-Specific Medical Devices to Rationally Designed Meta-Biomaterials

    PubMed Central

    Zadpoor, Amir A.

    2017-01-01

    Recent advances in additive manufacturing (AM) techniques in terms of accuracy, reliability, the range of processable materials, and commercial availability have made them promising candidates for production of functional parts including those used in the biomedical industry. The complexity-for-free feature offered by AM means that very complex designs become feasible to manufacture, while batch-size-indifference enables fabrication of fully patient-specific medical devices. Design for AM (DfAM) approaches aim to fully utilize those features for development of medical devices with substantially enhanced performance and biomaterials with unprecedented combinations of favorable properties that originate from complex geometrical designs at the micro-scale. This paper reviews the most important approaches in DfAM particularly those applicable to additive bio-manufacturing including image-based design pipelines, parametric and non-parametric designs, metamaterials, rational and computationally enabled design, topology optimization, and bio-inspired design. Areas with limited research have been identified and suggestions have been made for future research. The paper concludes with a brief discussion on the practical aspects of DfAM and the potential of combining AM with subtractive and formative manufacturing processes in so-called hybrid manufacturing processes. PMID:28757572

  17. Long-wavelength infrared (LWIR) quantum-dot infrared photodetector (QDIP) focal plane array

    NASA Astrophysics Data System (ADS)

    Gunapala, S. D.; Bandara, S. V.; Hill, C. J.; Ting, D. Z.; Liu, J. K.; Rafol, S. B.; Blazejewski, E. R.; Mumolo, J. M.; Keo, S. A.; Krishna, S.; Chang, Y. C.; Shott, C. A.

    2006-05-01

    We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDIPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of ~ 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45o and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1μm devices has reached ~ 1 x 1010 Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDIP focal plane array. This QDIP focal plane array has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K, which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

  18. Long-Wavelength Infrared (LWIR) Quantum Dot Infrared Photodetector (QDIP) Focal Plane Array

    NASA Technical Reports Server (NTRS)

    Gunapala, Sarath D.; Bandara, S. V.; Liu, J. K.; Hill, C. J.; Rafol, S. B.; Mumolo, J. M.; Shott, C. A.

    2006-01-01

    We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of approx. 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45 deg. and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1 micrometer devices has reached approx. 1 x 10(exp 10) Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDP focal plane array. This QDIP focal plane may has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

  19. Multistate Memristive Tantalum Oxide Devices for Ternary Arithmetic

    PubMed Central

    Kim, Wonjoo; Chattopadhyay, Anupam; Siemon, Anne; Linn, Eike; Waser, Rainer; Rana, Vikas

    2016-01-01

    Redox-based resistive switching random access memory (ReRAM) offers excellent properties to implement future non-volatile memory arrays. Recently, the capability of two-state ReRAMs to implement Boolean logic functionality gained wide interest. Here, we report on seven-states Tantalum Oxide Devices, which enable the realization of an intrinsic modular arithmetic using a ternary number system. Modular arithmetic, a fundamental system for operating on numbers within the limit of a modulus, is known to mathematicians since the days of Euclid and finds applications in diverse areas ranging from e-commerce to musical notations. We demonstrate that multistate devices not only reduce the storage area consumption drastically, but also enable novel in-memory operations, such as computing using high-radix number systems, which could not be implemented using two-state devices. The use of high radix number system reduces the computational complexity by reducing the number of needed digits. Thus the number of calculation operations in an addition and the number of logic devices can be reduced. PMID:27834352

  20. Multistate Memristive Tantalum Oxide Devices for Ternary Arithmetic.

    PubMed

    Kim, Wonjoo; Chattopadhyay, Anupam; Siemon, Anne; Linn, Eike; Waser, Rainer; Rana, Vikas

    2016-11-11

    Redox-based resistive switching random access memory (ReRAM) offers excellent properties to implement future non-volatile memory arrays. Recently, the capability of two-state ReRAMs to implement Boolean logic functionality gained wide interest. Here, we report on seven-states Tantalum Oxide Devices, which enable the realization of an intrinsic modular arithmetic using a ternary number system. Modular arithmetic, a fundamental system for operating on numbers within the limit of a modulus, is known to mathematicians since the days of Euclid and finds applications in diverse areas ranging from e-commerce to musical notations. We demonstrate that multistate devices not only reduce the storage area consumption drastically, but also enable novel in-memory operations, such as computing using high-radix number systems, which could not be implemented using two-state devices. The use of high radix number system reduces the computational complexity by reducing the number of needed digits. Thus the number of calculation operations in an addition and the number of logic devices can be reduced.

  1. An ultrasensitive quartz crystal microbalance-micropillars based sensor for humidity detection

    NASA Astrophysics Data System (ADS)

    Wang, Pengtao; Su, Junwei; Su, Che-Fu; Dai, Wen; Cernigliaro, George; Sun, Hongwei

    2014-06-01

    A unique sensing device, which couples microscale pillars with quartz crystal microbalance (QCM) substrate to form a resonant system, is developed to achieve several orders of magnitude enhancement in sensitivity compared to conventional QCM sensors. In this research, Polymethyl Methacrylate (PMMA) micropillars are fabricated on a QCM substrate using nanoimprinting lithography. The effects of pillar geometry and physical properties, tuned by molecular weight (MW) of PMMA, on the resonant characteristics of QCM-micropillars device are systematically investigated. It is found that the resonant frequency shift increases with increasing MW. The coupled QCM-micropillars device displays nonlinear frequency response, which is opposite to the linear response of conventional QCM devices. In addition, a positive resonant frequency shift is captured near the resonant point of the coupled QCM-micropillars system. Humidity detection experiments show that compared to current nanoscale feature based QCM sensors, QCM-micropillars devices offer higher sensitivity and moderate response time. This research points to a novel way of improving sensitivity of acoustic wave sensors without the need for fabricating surface nanostructures.

  2. Multistate Memristive Tantalum Oxide Devices for Ternary Arithmetic

    NASA Astrophysics Data System (ADS)

    Kim, Wonjoo; Chattopadhyay, Anupam; Siemon, Anne; Linn, Eike; Waser, Rainer; Rana, Vikas

    2016-11-01

    Redox-based resistive switching random access memory (ReRAM) offers excellent properties to implement future non-volatile memory arrays. Recently, the capability of two-state ReRAMs to implement Boolean logic functionality gained wide interest. Here, we report on seven-states Tantalum Oxide Devices, which enable the realization of an intrinsic modular arithmetic using a ternary number system. Modular arithmetic, a fundamental system for operating on numbers within the limit of a modulus, is known to mathematicians since the days of Euclid and finds applications in diverse areas ranging from e-commerce to musical notations. We demonstrate that multistate devices not only reduce the storage area consumption drastically, but also enable novel in-memory operations, such as computing using high-radix number systems, which could not be implemented using two-state devices. The use of high radix number system reduces the computational complexity by reducing the number of needed digits. Thus the number of calculation operations in an addition and the number of logic devices can be reduced.

  3. GaSb thermophotovoltaic cells grown on GaAs by molecular beam epitaxy using interfacial misfit arrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Juang, Bor-Chau, E-mail: bcjuang@ucla.edu; Laghumavarapu, Ramesh B.; Foggo, Brandon J.

    There exists a long-term need for foreign substrates on which to grow GaSb-based optoelectronic devices. We address this need by using interfacial misfit arrays to grow GaSb-based thermophotovoltaic cells directly on GaAs (001) substrates and demonstrate promising performance. We compare these cells to control devices grown on GaSb substrates to assess device properties and material quality. The room temperature dark current densities show similar characteristics for both cells on GaAs and on GaSb. Under solar simulation the cells on GaAs exhibit an open-circuit voltage of 0.121 V and a short-circuit current density of 15.5 mA/cm{sup 2}. In addition, the cells on GaAsmore » substrates maintain 10% difference in spectral response to those of the control cells over a large range of wavelengths. While the cells on GaSb substrates in general offer better performance than the cells on GaAs substrates, the cost-savings and scalability offered by GaAs substrates could potentially outweigh the reduction in performance. By further optimizing GaSb buffer growth on GaAs substrates, Sb-based compound semiconductors grown on GaAs substrates with similar performance to devices grown directly on GaSb substrates could be realized.« less

  4. Tunable Electrical and Optical Characteristics in Monolayer Graphene and Few-Layer MoS2 Heterostructure Devices.

    PubMed

    Rathi, Servin; Lee, Inyeal; Lim, Dongsuk; Wang, Jianwei; Ochiai, Yuichi; Aoki, Nobuyuki; Watanabe, Kenji; Taniguchi, Takashi; Lee, Gwan-Hyoung; Yu, Young-Jun; Kim, Philip; Kim, Gil-Ho

    2015-08-12

    Lateral and vertical two-dimensional heterostructure devices, in particular graphene-MoS2, have attracted profound interest as they offer additional functionalities over normal two-dimensional devices. Here, we have carried out electrical and optical characterization of graphene-MoS2 heterostructure. The few-layer MoS2 devices with metal electrode at one end and monolayer graphene electrode at the other end show nonlinearity in drain current with drain voltage sweep due to asymmetrical Schottky barrier height at the contacts and can be modulated with an external gate field. The doping effect of MoS2 on graphene was observed as double Dirac points in the transfer characteristics of the graphene field-effect transistor (FET) with a few-layer MoS2 overlapping the middle part of the channel, whereas the underlapping of graphene have negligible effect on MoS2 FET characteristics, which showed typical n-type behavior. The heterostructure also exhibits a strongest optical response for 520 nm wavelength, which decreases with higher wavelengths. Another distinct feature observed in the heterostructure is the peak in the photocurrent around zero gate voltage. This peak is distinguished from conventional MoS2 FETs, which show a continuous increase in photocurrent with back-gate voltage. These results offer significant insight and further enhance the understanding of the graphene-MoS2 heterostructure.

  5. MinT: Middleware for Cooperative Interaction of Things

    PubMed Central

    Jeon, Soobin; Jung, Inbum

    2017-01-01

    This paper proposes an Internet of Things (IoT) middleware called Middleware for Cooperative Interaction of Things (MinT). MinT supports a fully distributed IoT environment in which IoT devices directly connect to peripheral devices easily construct a local or global network, and share their data in an energy efficient manner. MinT provides a sensor abstract layer, a system layer and an interaction layer. These enable integrated sensing device operations, efficient resource management, and active interconnection between peripheral IoT devices. In addition, MinT provides a high-level API to develop IoT devices easily for IoT device developers. We aim to enhance the energy efficiency and performance of IoT devices through the performance improvements offered by MinT resource management and request processing. The experimental results show that the average request rate increased by 25% compared to Californium, which is a middleware for efficient interaction in IoT environments with powerful performance, an average response time decrease of 90% when resource management was used, and power consumption decreased by up to 68%. Finally, the proposed platform can reduce the latency and power consumption of IoT devices. PMID:28632182

  6. MinT: Middleware for Cooperative Interaction of Things.

    PubMed

    Jeon, Soobin; Jung, Inbum

    2017-06-20

    This paper proposes an Internet of Things (IoT) middleware called Middleware for Cooperative Interaction of Things (MinT). MinT supports a fully distributed IoT environment in which IoT devices directly connect to peripheral devices easily construct a local or global network, and share their data in an energy efficient manner. MinT provides a sensor abstract layer, a system layer and an interaction layer. These enable integrated sensing device operations, efficient resource management, and active interconnection between peripheral IoT devices. In addition, MinT provides a high-level API to develop IoT devices easily for IoT device developers. We aim to enhance the energy efficiency and performance of IoT devices through the performance improvements offered by MinT resource management and request processing. The experimental results show that the average request rate increased by 25% compared to Californium, which is a middleware for efficient interaction in IoT environments with powerful performance, an average response time decrease of 90% when resource management was used, and power consumption decreased by up to 68%. Finally, the proposed platform can reduce the latency and power consumption of IoT devices.

  7. High-Performance Screen-Printed Thermoelectric Films on Fabrics

    DOE PAGES

    Shin, Sunmi; Kumar, Rajan; Roh, Jong Wook; ...

    2017-08-04

    Printing techniques could offer a scalable approach to fabricate thermoelectric (TE) devices on flexible substrates for power generation used in wearable devices and personalized thermo-regulation. However, typical printing processes need a large concentration of binder additives, which often render a detrimental effect on electrical transport of the printed TE layers. Here, we report scalable screenprinting of TE layers on flexible fiber glass fabrics, by rationally optimizing the printing inks consisting of TE particles (p-type Bi 0.5Sb 1.5Te 3 or n-type Bi 2Te 2.7Se 0.3), binders, and organic solvents. We identified a suitable binder additive, methyl cellulose, which offers suitable viscositymore » for printability at a very small concentration (0.45–0.60 wt.%), thus minimizing its negative impact on electrical transport. Following printing, the binders were subsequently burnt off via sintering and hot pressing. We found that the nanoscale defects left behind after the binder burnt off became effective phonon scattering centers, leading to low lattice thermal conductivity in the printed n-type material. With the high electrical conductivity and low thermal conductivity, the screen-printed TE layers showed high room-temperature ZT values of 0.65 and 0.81 for p-type and n-type, respectively.« less

  8. High-Performance Screen-Printed Thermoelectric Films on Fabrics.

    PubMed

    Shin, Sunmi; Kumar, Rajan; Roh, Jong Wook; Ko, Dong-Su; Kim, Hyun-Sik; Kim, Sang Il; Yin, Lu; Schlossberg, Sarah M; Cui, Shuang; You, Jung-Min; Kwon, Soonshin; Zheng, Jianlin; Wang, Joseph; Chen, Renkun

    2017-08-04

    Printing techniques could offer a scalable approach to fabricate thermoelectric (TE) devices on flexible substrates for power generation used in wearable devices and personalized thermo-regulation. However, typical printing processes need a large concentration of binder additives, which often render a detrimental effect on electrical transport of the printed TE layers. Here, we report scalable screen-printing of TE layers on flexible fiber glass fabrics, by rationally optimizing the printing inks consisting of TE particles (p-type Bi 0.5 Sb 1.5 Te 3 or n-type Bi 2 Te 2.7 Se 0.3 ), binders, and organic solvents. We identified a suitable binder additive, methyl cellulose, which offers suitable viscosity for printability at a very small concentration (0.45-0.60 wt.%), thus minimizing its negative impact on electrical transport. Following printing, the binders were subsequently burnt off via sintering and hot pressing. We found that the nanoscale defects left behind after the binder burnt off became effective phonon scattering centers, leading to low lattice thermal conductivity in the printed n-type material. With the high electrical conductivity and low thermal conductivity, the screen-printed TE layers showed high room-temperature ZT values of 0.65 and 0.81 for p-type and n-type, respectively.

  9. High-Performance Screen-Printed Thermoelectric Films on Fabrics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Sunmi; Kumar, Rajan; Roh, Jong Wook

    Printing techniques could offer a scalable approach to fabricate thermoelectric (TE) devices on flexible substrates for power generation used in wearable devices and personalized thermo-regulation. However, typical printing processes need a large concentration of binder additives, which often render a detrimental effect on electrical transport of the printed TE layers. Here, we report scalable screenprinting of TE layers on flexible fiber glass fabrics, by rationally optimizing the printing inks consisting of TE particles (p-type Bi 0.5Sb 1.5Te 3 or n-type Bi 2Te 2.7Se 0.3), binders, and organic solvents. We identified a suitable binder additive, methyl cellulose, which offers suitable viscositymore » for printability at a very small concentration (0.45–0.60 wt.%), thus minimizing its negative impact on electrical transport. Following printing, the binders were subsequently burnt off via sintering and hot pressing. We found that the nanoscale defects left behind after the binder burnt off became effective phonon scattering centers, leading to low lattice thermal conductivity in the printed n-type material. With the high electrical conductivity and low thermal conductivity, the screen-printed TE layers showed high room-temperature ZT values of 0.65 and 0.81 for p-type and n-type, respectively.« less

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tom, N.; Lawson, M.; Yu, Y. H.

    WEC-Sim is a midfidelity numerical tool for modeling wave energy conversion devices. The code uses the MATLAB SimMechanics package to solve multibody dynamics and models wave interactions using hydrodynamic coefficients derived from frequency-domain boundary-element methods. This paper presents the new modeling features introduced in the latest release of WEC-Sim. The first feature discussed conversion of the fluid memory kernel to a state-space form. This enhancement offers a substantial computational benefit after the hydrodynamic body-to-body coefficients are introduced and the number of interactions increases exponentially with each additional body. Additional features include the ability to calculate the wave-excitation forces based onmore » the instantaneous incident wave angle, allowing the device to weathervane, as well as import a user-defined wave elevation time series. A review of the hydrodynamic theory for each feature is provided and the successful implementation is verified using test cases.« less

  11. Specific barriers to the conduct of randomised clinical trials on medical devices.

    PubMed

    Neugebauer, Edmund A M; Rath, Ana; Antoine, Sunya-Lee; Eikermann, Michaela; Seidel, Doerthe; Koenen, Carsten; Jacobs, Esther; Pieper, Dawid; Laville, Martine; Pitel, Séverine; Martinho, Cecilia; Djurisic, Snezana; Demotes-Mainard, Jacques; Kubiak, Christine; Bertele, Vittorio; Jakobsen, Janus C; Garattini, Silvio; Gluud, Christian

    2017-09-13

    Medical devices play an important role in the diagnosis, prevention, treatment and care of diseases. However, compared to pharmaceuticals, there is no rigorous formal regulation for demonstration of benefits and exclusion of harms to patients. The medical device industry argues that the classical evidence hierarchy cannot be applied for medical devices, as randomised clinical trials are impossible to perform. This article aims to identify the barriers for randomised clinical trials on medical devices. Systematic literature searches without meta-analysis and internal European Clinical Research Infrastructure Network (ECRIN) communications taking place during face-to-face meetings and telephone conferences from 2013 to 2017 within the context of the ECRIN Integrating Activity (ECRIN-IA) project. In addition to the barriers that exist for all trials, we identified three major barriers for randomised clinical trials on medical devices, namely: (1) randomisation, including timing of assessment, acceptability, blinding, choice of the comparator group and considerations on the learning curve; (2) difficulties in determining appropriate outcomes; and (3) the lack of scientific advice, regulations and transparency. The present review offers potential solutions to break down the barriers identified, and argues for applying the randomised clinical trial design when assessing the benefits and harms of medical devices.

  12. A General Method for the Chemical Synthesis of Large-Scale, Seamless Transition Metal Dichalcogenide Electronics.

    PubMed

    Li, Li; Guo, Yichuan; Sun, Yuping; Yang, Long; Qin, Liang; Guan, Shouliang; Wang, Jinfen; Qiu, Xiaohui; Li, Hongbian; Shang, Yuanyuan; Fang, Ying

    2018-03-01

    The capability to directly build atomically thin transition metal dichalcogenide (TMD) devices by chemical synthesis offers important opportunities to achieve large-scale electronics and optoelectronics with seamless interfaces. Here, a general approach for the chemical synthesis of a variety of TMD (e.g., MoS 2 , WS 2 , and MoSe 2 ) device arrays over large areas is reported. During chemical vapor deposition, semiconducting TMD channels and metallic TMD/carbon nanotube (CNT) hybrid electrodes are simultaneously formed on CNT-patterned substrate, and then coalesce into seamless devices. Chemically synthesized TMD devices exhibit attractive electrical and mechanical properties. It is demonstrated that chemically synthesized MoS 2 -MoS 2 /CNT devices have Ohmic contacts between MoS 2 /CNT hybrid electrodes and MoS 2 channels. In addition, MoS 2 -MoS 2 /CNT devices show greatly enhanced mechanical stability and photoresponsivity compared with conventional gold-contacted devices, which makes them suitable for flexible optoelectronics. Accordingly, a highly flexible pixel array based on chemically synthesized MoS 2 -MoS 2 /CNT photodetectors is applied for image sensing. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Additive manufacturing: From implants to organs.

    PubMed

    Douglas, Tania S

    2014-05-12

    Additive manufacturing (AM) constructs 3D objects layer by layer under computer control from 3D models. 3D printing is one example of this kind of technology. AM offers geometric flexibility in its products and therefore allows customisation to suit individual needs. Clinical success has been shown with models for surgical planning, implants, assistive devices and scaffold-based tissue engineering. The use of AM to print tissues and organs that mimic nature in structure and function remains an elusive goal, but has the potential to transform personalised medicine, drug development and scientific understanding of the mechanisms of disease. 

  14. Measurement-device-independent quantum cryptography

    DOE PAGES

    Xu, Feihu; Curty, Marcos; Qi, Bing; ...

    2014-12-18

    In theory, quantum key distribution (QKD) provides information-theoretic security based on the laws of physics. Owing to the imperfections of real-life implementations, however, there is a big gap between the theory and practice of QKD, which has been recently exploited by several quantum hacking activities. To fill this gap, a novel approach, called measurement-device-independent QKD (mdiQKD), has been proposed. In addition, it can remove all side-channels from the measurement unit, arguably the most vulnerable part in QKD systems, thus offering a clear avenue toward secure QKD realisations. In this study, we review the latest developments in the framework of mdiQKD,more » together with its assumptions, strengths, and weaknesses.« less

  15. Development of a digital-micromirror-device-based multishot snapshot spectral imaging system.

    PubMed

    Wu, Yuehao; Mirza, Iftekhar O; Arce, Gonzalo R; Prather, Dennis W

    2011-07-15

    We report on the development of a digital-micromirror-device (DMD)-based multishot snapshot spectral imaging (DMD-SSI) system as an alternative to current piezostage-based multishot coded aperture snapshot spectral imager (CASSI) systems. In this system, a DMD is used to implement compressive sensing (CS) measurement patterns for reconstructing the spatial/spectral information of an imaging scene. Based on the CS measurement results, we demonstrated the concurrent reconstruction of 24 spectral images. The DMD-SSI system is versatile in nature as it can be used to implement independent CS measurement patterns in addition to spatially shifted patterns that piezostage-based systems can offer. © 2011 Optical Society of America

  16. Novel conformal organic antireflective coatings for advanced I-line lithography

    NASA Astrophysics Data System (ADS)

    Deshpande, Shreeram V.; Nowak, Kelly A.; Fowler, Shelly; Williams, Paul; Arjona, Mikko

    2001-08-01

    Flash memory chips are playing a critical role in semiconductor devices due to increased popularity of hand held electronic communication devices such as cell phones and PDAs (personal Digital Assistants). Flash memory offers two primary advantages in semiconductor devices. First, it offers flexibility of in-circuit programming capability to reduce the loss from programming errors and to significantly reduce commercialization time to market for new devices. Second, flash memory has a double density memory capability through stacked gate structures which increases the memory capability and thus saves significantly on chip real estate. However, due to stacked gate structures the requirements for manufacturing of flash memory devices are significantly different from traditional memory devices. Stacked gate structures also offer unique challenges to lithographic patterning materials such as Bottom Anti-Reflective Coating (BARC) compositions used to achieve CD control and to minimize standing wave effect in photolithography. To be applicable in flash memory manufacturing a BARC should form a conformal coating on high topography of stacked gate features as well as provide the normal anti-reflection properties for CD control. In this paper we report on a new highly conformal advanced i-line BARC for use in design and manufacture of flash memory devices. Conformal BARCs being significantly thinner in trenches than the planarizing BARCs offer the advantage of reducing BARC overetch and thus minimizing resist thickness loss.

  17. Evaluation of the confusion matrix method in the validation of an automated system for measuring feeding behaviour of cattle.

    PubMed

    Ruuska, Salla; Hämäläinen, Wilhelmiina; Kajava, Sari; Mughal, Mikaela; Matilainen, Pekka; Mononen, Jaakko

    2018-03-01

    The aim of the present study was to evaluate empirically confusion matrices in device validation. We compared the confusion matrix method to linear regression and error indices in the validation of a device measuring feeding behaviour of dairy cattle. In addition, we studied how to extract additional information on classification errors with confusion probabilities. The data consisted of 12 h behaviour measurements from five dairy cows; feeding and other behaviour were detected simultaneously with a device and from video recordings. The resulting 216 000 pairs of classifications were used to construct confusion matrices and calculate performance measures. In addition, hourly durations of each behaviour were calculated and the accuracy of measurements was evaluated with linear regression and error indices. All three validation methods agreed when the behaviour was detected very accurately or inaccurately. Otherwise, in the intermediate cases, the confusion matrix method and error indices produced relatively concordant results, but the linear regression method often disagreed with them. Our study supports the use of confusion matrix analysis in validation since it is robust to any data distribution and type of relationship, it makes a stringent evaluation of validity, and it offers extra information on the type and sources of errors. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Simplifying Nanowire Hall Effect Characterization by Using a Three-Probe Device Design.

    PubMed

    Hultin, Olof; Otnes, Gaute; Samuelson, Lars; Storm, Kristian

    2017-02-08

    Electrical characterization of nanowires is a time-consuming and challenging task due to the complexity of single nanowire device fabrication and the difficulty in interpreting the measurements. We present a method to measure Hall effect in nanowires using a three-probe device that is simpler to fabricate than previous four-probe nanowire Hall devices and allows characterization of nanowires with smaller diameter. Extraction of charge carrier concentration from the three-probe measurements using an analytical model is discussed and compared to simulations. The validity of the method is experimentally verified by a comparison between results obtained with the three-probe method and results obtained using four-probe nanowire Hall measurements. In addition, a nanowire with a diameter of only 65 nm is characterized to demonstrate the capabilities of the method. The three-probe Hall effect method offers a relatively fast and simple, yet accurate way to quantify the charge carrier concentration in nanowires and has the potential to become a standard characterization technique for nanowires.

  19. The total artificial heart for biventricular heart failure and beyond.

    PubMed

    Kasirajan, Vigneshwar; Tang, Daniel G; Katlaps, Gundars J; Shah, Keyur B

    2012-05-01

    Treatment options for late-stage biventricular heart failure are limited but include medical therapy with intravenous inotropes, biventricular assist devices (Bi-VADs) and the total artificial heart (TAH). In this manuscript, we review the indications, surgical techniques and outcomes for the TAH. The TAH offers biventricular replacement, rather than 'assistance', as the device is placed orthotopically after excision of the entire ventricular myocardium and all four native valves. In contrast to patients with Bi-VADs, patients with the TAH have no postoperative inotrope requirements, arrhythmias or inflow/outflow cannulae-related complications. Additionally, patients participate in rehabilitation early after device placement and the development of a portable drive may facilitate hospital discharge in the USA. Furthermore, total heart replacement may be ideal for heart failure associated with unique anatomical and mechanical complications. The TAH is an effective therapeutic option for the treatment of patients dying of heart failure who may not be suitable candidates for left ventricular assist devices.

  20. Multi-foci metalens for spin and orbital angular momentum interaction

    NASA Astrophysics Data System (ADS)

    Mei, Shengtao; Mehmood, M. Q.; Huang, Kun; Qiu, Cheng-Wei

    2015-09-01

    The development of metasurface, capable of controlling wave-fronts through interfacial phase discontinuity, offers a fascinating methodology for designing two dimensional miniaturized optical devices. Owing to an additional advantage of the enhanced useful transmission via Bainet-inverted matasurface, we exploit them to demonstrate an intriguing concept of merging the phase-profiles of two distinct optical devices, a lens and a spiral phase plate, to realize an ultrathin nanostructured optical vortex lens. The proposed device can has multiple focal planes along the longitudinal direction; whereas the number of focal plans, corresponding topological charges and focal lengths can readily be tailored to meet any desired requirements. Meanwhile, the dual-polarity feature of the optical vertex metalens exhibits spin controlled real and virtual focal plans, while dispersionless aptitude of nanobars enables its working over the broadband. The concept unveils a novel way of employing metasurface, to engraft the phase profiles of multiple bulk devices, to achieve unique functionalities for promising applications in integrated photonics.

  1. Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables

    PubMed Central

    Haugen Mikalsen, Martin; Woldaregay, Ashenafi Zebene; Muzny, Miroslav; Hartvigsen, Gunnar; Hopstock, Laila Arnesdatter; Grimsgaard, Sameline

    2018-01-01

    Background New fitness trackers and smartwatches are released to the consumer market every year. These devices are equipped with different sensors, algorithms, and accompanying mobile apps. With recent advances in mobile sensor technology, privately collected physical activity data can be used as an addition to existing methods for health data collection in research. Furthermore, data collected from these devices have possible applications in patient diagnostics and treatment. With an increasing number of diverse brands, there is a need for an overview of device sensor support, as well as device applicability in research projects. Objective The objective of this study was to examine the availability of wrist-worn fitness wearables and analyze availability of relevant fitness sensors from 2011 to 2017. Furthermore, the study was designed to assess brand usage in research projects, compare common brands in terms of developer access to collected health data, and features to consider when deciding which brand to use in future research. Methods We searched for devices and brand names in six wearable device databases. For each brand, we identified additional devices on official brand websites. The search was limited to wrist-worn fitness wearables with accelerometers, for which we mapped brand, release year, and supported sensors relevant for fitness tracking. In addition, we conducted a Medical Literature Analysis and Retrieval System Online (MEDLINE) and ClinicalTrials search to determine brand usage in research projects. Finally, we investigated developer accessibility to the health data collected by identified brands. Results We identified 423 unique devices from 132 different brands. Forty-seven percent of brands released only one device. Introduction of new brands peaked in 2014, and the highest number of new devices was introduced in 2015. Sensor support increased every year, and in addition to the accelerometer, a photoplethysmograph, for estimating heart rate, was the most common sensor. Out of the brands currently available, the five most often used in research projects are Fitbit, Garmin, Misfit, Apple, and Polar. Fitbit is used in twice as many validation studies as any other brands and is registered in ClinicalTrials studies 10 times as often as other brands. Conclusions The wearable landscape is in constant change. New devices and brands are released every year, promising improved measurements and user experience. At the same time, other brands disappear from the consumer market for various reasons. Advances in device quality offer new opportunities for research. However, only a few well-established brands are frequently used in research projects, and even less are thoroughly validated. PMID:29567635

  2. 21 CFR 807.40 - Establishment registration and device listing for foreign establishments importing or offering...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... submit the name, address, and phone number of its United States agent as part of its initial and updated... phone number to FDA within 10-business days of the change. (c) No device may be imported or offered for...

  3. 21 CFR 807.40 - Establishment registration and device listing for foreign establishments importing or offering...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... submit the name, address, and phone number of its United States agent as part of its initial and updated... phone number to FDA within 10-business days of the change. (c) No device may be imported or offered for...

  4. [Self-active physical thrombosis prophylaxis in the patients' bed with the Phlebostep: acceptance and measurement of venous blood flow in immobilized patients].

    PubMed

    Olivier, L C; Ostovan, D; Heywinkel, W; Kendoff, D; Wolfhard, U

    2007-11-01

    Despite the broad use of low molecular weight heparin, deep vein thrombosis is still a relevant risk for immobilized patients in orthopedic surgery. Patients can reduce this risk by active training exercises with a muscle pump. The aim of this study was to test the acceptance and effect of a self-developed training device to accelerate venous return as well as a technical optimization. The device was installed for in-patients in orthopedic and traumatology departments. A simple pillow-like device was developed, which can be positioned against the foot end of the patient's bed (Phlebostep). The device gives a sound-based feedback to the patient while pushing actively against it with complete ankle flexion. A digital integrated counter device allows direct feedback to the physician and nursing staff at any time. Initial testing including duplex sonography for venous flow measurements were done on 10 orthopedic in-patients. Prior testing on 7 healthy volunteers was carried out to define the effect of various amounts of pressure on the Phlebostep on the venous blood flow. Additionally, a questionnaire on the general acceptance and user-friendliness was filled out by 84 patients who had used the Phlebostep. The optimal pressure force was defined as 35 mmHg for further measurements. The venous flow measurements in the 10 postoperative patients revealed an increased venous blood flow in the affected leg by an average of 99.9%. Analysis of the questionnaire from the 84 patients showed a high degree of acceptance. In addition to the technical feasibility, this study showed that use of the Phlebostep resulted on average in a doubling of venous return. The increase of venous flow offers an additional effective device for thrombosis prophylaxis through patient's own active movements and is clearly superior to the use of devices such as antithrombosis stockings alone. The Phlebostep found a high degree of acceptance with the patients.

  5. Concerns about usage of smartphones in operating room and critical care scenario

    PubMed Central

    Attri, JP; Khetarpal, R; Chatrath, V; Kaur, J

    2016-01-01

    Smartphones and tablets have taken a central place in the lives of health care professionals. Their use has dramatically improved the communication and has become an important learning tool as the medical information can be assessed online at anytime. In critical care settings, use of smartphone facilitates quick passage of information through E-mail messaging and getting feedback from the concerned physician quickly, thereby reducing medical errors. However, in addition to the benefits offered, these devices have become a significant source of nosocomial infections, distraction for medical professionals and interfere with medical equipments. They may also put privacy and security of patients at stake. The benefits could be severely undermined if abuse and over use are not kept in check. This review article focuses on various applications of smartphones in healthcare practices, drawback of the use of these devices and the recommendations regarding the safe use of these devices. PMID:26952181

  6. Concerns about usage of smartphones in operating room and critical care scenario.

    PubMed

    Attri, J P; Khetarpal, R; Chatrath, V; Kaur, J

    2016-01-01

    Smartphones and tablets have taken a central place in the lives of health care professionals. Their use has dramatically improved the communication and has become an important learning tool as the medical information can be assessed online at anytime. In critical care settings, use of smartphone facilitates quick passage of information through E-mail messaging and getting feedback from the concerned physician quickly, thereby reducing medical errors. However, in addition to the benefits offered, these devices have become a significant source of nosocomial infections, distraction for medical professionals and interfere with medical equipments. They may also put privacy and security of patients at stake. The benefits could be severely undermined if abuse and over use are not kept in check. This review article focuses on various applications of smartphones in healthcare practices, drawback of the use of these devices and the recommendations regarding the safe use of these devices.

  7. Nanophotonic integrated circuits from nanoresonators grown on silicon.

    PubMed

    Chen, Roger; Ng, Kar Wei; Ko, Wai Son; Parekh, Devang; Lu, Fanglu; Tran, Thai-Truong D; Li, Kun; Chang-Hasnain, Connie

    2014-07-07

    Harnessing light with photonic circuits promises to catalyse powerful new technologies much like electronic circuits have in the past. Analogous to Moore's law, complexity and functionality of photonic integrated circuits depend on device size and performance scale. Semiconductor nanostructures offer an attractive approach to miniaturize photonics. However, shrinking photonics has come at great cost to performance, and assembling such devices into functional photonic circuits has remained an unfulfilled feat. Here we demonstrate an on-chip optical link constructed from InGaAs nanoresonators grown directly on a silicon substrate. Using nanoresonators, we show a complete toolkit of circuit elements including light emitters, photodetectors and a photovoltaic power supply. Devices operate with gigahertz bandwidths while consuming subpicojoule energy per bit, vastly eclipsing performance of prior nanostructure-based optoelectronics. Additionally, electrically driven stimulated emission from an as-grown nanostructure is presented for the first time. These results reveal a roadmap towards future ultradense nanophotonic integrated circuits.

  8. Engineering charge transport by heterostructuring solution-processed semiconductors

    NASA Astrophysics Data System (ADS)

    Voznyy, Oleksandr; Sutherland, Brandon R.; Ip, Alexander H.; Zhitomirsky, David; Sargent, Edward H.

    2017-06-01

    Solution-processed semiconductor devices are increasingly exploiting heterostructuring — an approach in which two or more materials with different energy landscapes are integrated into a composite system. Heterostructured materials offer an additional degree of freedom to control charge transport and recombination for more efficient optoelectronic devices. By exploiting energetic asymmetry, rationally engineered heterostructured materials can overcome weaknesses, augment strengths and introduce emergent physical phenomena that are otherwise inaccessible to single-material systems. These systems see benefit and application in two distinct branches of charge-carrier manipulation. First, they influence the balance between excitons and free charges to enhance electron extraction in solar cells and photodetectors. Second, they promote radiative recombination by spatially confining electrons and holes, which increases the quantum efficiency of light-emitting diodes. In this Review, we discuss advances in the design and composition of heterostructured materials, consider their implementation in semiconductor devices and examine unexplored paths for future advancement in the field.

  9. Electrically tunable superconducting terahertz metamaterial with low insertion loss and high switchable ratios

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Chun; Zhang, Caihong, E-mail: chzhang@nju.edu.cn; Hu, Guoliang

    2016-07-11

    With the emergence and development of artificially structured electromagnetic materials, active terahertz (THz) metamaterial devices have attracted significant attention in recent years. Tunability of transmission is desirable for many applications. For example, short-range wireless THz communications and ultrafast THz interconnects require switches and modulators. However, the tunable range of transmission amplitude of existing THz metamaterial devices is not satisfactory. In this article, we experimentally demonstrate an electrically tunable superconducting niobium nitride metamaterial device and employ a hybrid coupling model to analyze its optical transmission characteristics. The maximum transmission coefficient at 0.507 THz is 0.98 and decreases to 0.19 when themore » applied voltage increases to 0.9 V. A relative transmittance change of 80.6% is observed, making this device an efficient narrowband THz switch. Additionally, the frequency of the peak is red shifted from 0.507 to 0.425 THz, which means that the device can be used to select the frequency. This study offers an alternative tuning method to existing optical, thermal, magnetic-field, and electric-field tuning, delivering a promising approach for designing active and miniaturized THz devices.« less

  10. Potentials and challenges of integration for complex metal oxides in CMOS devices and beyond

    NASA Astrophysics Data System (ADS)

    Kim, Y.; Pham, C.; Chang, J. P.

    2015-02-01

    This review focuses on recent accomplishments on complex metal oxide based multifunctional materials and the potential they hold in advancing integrated circuits. It begins with metal oxide based high-κ materials to highlight the success of their integration since 45 nm complementary metal-oxide-semiconductor (CMOS) devices. By simultaneously offering a higher dielectric constant for improved capacitance as well as providing a thicker physical layer to prevent the quantum mechanical tunnelling of electrons, high-κ materials have enabled the continued down-scaling of CMOS based devices. The most recent technology driver has been the demand to lower device power consumption, which requires the design and synthesis of novel materials, such as complex metal oxides that exhibit remarkable tunability in their ferromagnetic, ferroelectric and multiferroic properties. These properties make them suitable for a wide variety of applications such as magnetoelectric random access memory, radio frequency band pass filters, antennae and magnetic sensors. Single-phase multiferroics, while rare, offer unique functionalities which have motivated much scientific and technological research to ascertain the origins of their multiferroicity and their applicability to potential devices. However, due to the weak magnetoelectric coupling for single-phase multiferroics, engineered multiferroic composites based on magnetostrictive ferromagnets interfacing piezoelectrics or ferroelectrics have shown enhanced multiferroic behaviour from effective strain coupling at the interface. In addition, nanostructuring of the ferroic phases has demonstrated further improvement in the coupling effect. Therefore, single-phase and engineered composite multiferroics consisting of complex metal oxides are reviewed in terms of magnetoelectric coupling effects and voltage controlled ferromagnetic properties, followed by a review on the integration challenges that need to be overcome to realize the materials’ full potential.

  11. MEMS Louvers for Thermal Control

    NASA Technical Reports Server (NTRS)

    Champion, J. L.; Osiander, R.; Darrin, M. A. Garrison; Swanson, T. D.

    1998-01-01

    Mechanical louvers have frequently been used for spacecraft and instrument thermal control purposes. These devices typically consist of parallel or radial vanes, which can be opened or closed to vary the effective emissivity of the underlying surface. This project demonstrates the feasibility of using Micro-Electromechanical Systems (MEMS) technology to miniaturize louvers for such purposes. This concept offers the possibility of substituting the smaller, lighter weight, more rugged, and less costly MEMS devices for such mechanical louvers. In effect, a smart skin that self adjusts in response to environmental influences could be developed composed of arrays of thousands of miniaturized louvers. Several orders of magnitude size, weight, and volume decreases are potentially achieved using micro-electromechanical techniques. The use of this technology offers substantial benefits in spacecraft/instrument design, integration and testing, and flight operations. It will be particularly beneficial for the emerging smaller spacecraft and instruments of the future. In addition, this MEMS thermal louver technology can form the basis for related spacecraft instrument applications. The specific goal of this effort was to develop a preliminary MEMS device capable of modulating the effective emissivity of radiators on spacecraft. The concept pursued uses hinged panels, or louvers, in a manner such that heat emitted from the radiators is a function of louver angle. An electrostatic comb drive or other such actuator can control the louver position. The initial design calls for the louvers to be gold coated while the underlying surface is of high emissivity. Since, the base MEMS material, silicon, is transparent in the InfraRed (IR) spectrum, the device has a minimum emissivity when closed and a maximum emissivity when open. An initial set of polysilicon louver devices was designed at the Johns Hopkins Applied Physics Laboratory in conjunction with the Thermal Engineering Branch at NASA's Goddard Space Flight Center.

  12. Spherical gradient-index lenses as perfect imaging and maximum power transfer devices.

    PubMed

    Gordon, J M

    2000-08-01

    Gradient-index lenses can be viewed from the perspectives of both imaging and nonimaging optics, that is, in terms of both image fidelity and achievable flux concentration. The simple class of gradient-index lenses with spherical symmetry, often referred to as modified Luneburg lenses, is revisited. An alternative derivation for established solutions is offered; the method of Fermat's strings and the principle of skewness conservation are invoked. Then these nominally perfect imaging devices are examined from the additional vantage point of power transfer, and the degree to which they realize the thermodynamic limit to flux concentration is determined. Finally, the spherical gradient-index lens of the fish eye is considered as a modified Luneburg lens optimized subject to material constraints.

  13. 5.8kV SiC PiN Diode for Switching of High-Efficiency Inductive Pulsed Plasma Thruster Circuits

    NASA Technical Reports Server (NTRS)

    Toftul, Alexandra; Polzin, Kurt A.; Hudgins, Jerry L.

    2014-01-01

    Inductive Pulsed Plasma Thruster (IPPT) pulse circuits, such as those needed to operate the Pulsed Inductive Thruster (PIT), are required to quickly switch capacitor banks operating at a period of µs while conducting current at levels on the order of at least 10 kA. [1,2] For all iterations of the PIT to date, spark gaps have been used to discharge the capacitor bank through an inductive coil. Recent availability of fast, high-power solid state switching devices makes it possible to consider the use of semiconductor switches in modern IPPTs. In addition, novel pre-ionization schemes have led to a reduction in discharge energy per pulse for electric thrusters of this type, relaxing the switching requirements for these thrusters. [3,4] Solid state switches offer the advantage of greater controllability and reliability, as well as decreased drive circuit dimensions and mass relative to spark gap switches. The use of solid state devices such as Integrated Gate Bipolar Transistors (IGBTs), Gate Turn-off Thyristors (GTOs) and Silicon-Controlled Rectifiers (SCRs) often involves the use of power diodes. These semiconductor devices may be connected antiparallel to the switch for protection from reverse current, or used to reduce power loss in a circuit by clamping off current ringing. In each case, higher circuit efficiency may be achieved by using a diode that is able to transition, or 'switch,' from the forward conducting state ('on' state) to the reverse blocking state ('off' state) in the shortest amount of time, thereby minimizing current ringing and switching losses. Silicon Carbide (SiC) PiN diodes offer significant advantages to conventional fast-switching Silicon (Si) diodes for high power and fast switching applications. A wider band gap results in a breakdown voltage 10 times that of Si, so that a SiC device may have a thinner drift region for a given blocking voltage. [5] This leads to smaller, lighter devices for high voltage applications, as well as reduced forward conduction losses, faster reverse recovery time (faster turn-off), and lower-magnitude reverse recovery current. In addition, SiC devices have lower leakage current as compared to their Si counterparts, and a high thermal conductivity, potentially allowing the former to operate at higher temperatures with a smaller, lighter heatsink (or no heatsink at all).

  14. Thin Semiconductor/Metal Films For Infrared Devices

    NASA Technical Reports Server (NTRS)

    Lamb, James L.; Nagendra, Channamallappa L.

    1995-01-01

    Spectral responses of absorbers and reflectors tailored. Thin cermet films composites of metals and semiconductors undergoing development for use as broadband infrared reflectors and absorbers. Development extends concepts of semiconductor and dielectric films used as interference filters for infrared light and visible light. Composite films offer advantages over semiconductor films. Addition of metal particles contributes additional thermal conductivity, reducing thermal gradients and associated thermal stresses, with resultant enhancements of thermal stability. Because values of n in composite films made large, same optical effects achieved with lesser thicknesses. By decreasing thicknesses of films, one not only decreases weights but also contributes further to reductions of thermal stresses.

  15. Multifunctional CNT-polymer composites for ultra-tough structural supercapacitors and desalination devices.

    PubMed

    Benson, Jim; Kovalenko, Igor; Boukhalfa, Sofiane; Lashmore, David; Sanghadasa, Mohan; Yushin, Gleb

    2013-12-03

    Pulsed electrodeposition of polyaniline (PANI) allows the fabrication of flexible, electrically conductive, nonwoven PANI-carbon nanotube (PANI-CNT) composite fabrics. They possess specific tensile strength and a modulus of toughness higher than that of aluminum matrix composites, titanium and aluminum alloys, steels, and many other structural materials. Electrochemical tests show that these nanocomposites additionally offer excellent cycle stability and ion electro-sorption and storage properties. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Flexible programmable logic module

    DOEpatents

    Robertson, Perry J.; Hutchinson, Robert L.; Pierson, Lyndon G.

    2001-01-01

    The circuit module of this invention is a VME board containing a plurality of programmable logic devices (PLDs), a controlled impedance clock tree, and interconnecting buses. The PLDs are arranged to permit systolic processing of a problem by offering wide data buses and a plurality of processing nodes. The board contains a clock reference and clock distribution tree that can drive each of the PLDs with two critically timed clock references. External clock references can be used to drive additional circuit modules all operating from the same synchronous clock reference.

  17. American Academy of Pediatrics: Children, adolescents, and television.

    PubMed

    2001-02-01

    This statement describes the possible negative health effects of television viewing on children and adolescents, such as violent or aggressive behavior, substance use, sexual activity, obesity, poor body image, and decreased school performance. In addition to the television ratings system and the v-chip (electronic device to block programming), media education is an effective approach to mitigating these potential problems. The American Academy of Pediatrics offers a list of recommendations on this issue for pediatricians and for parents, the federal government, and the entertainment industry.

  18. Statistical analysis of road-vehicle-driver interaction as an enabler to designing behavioural models

    NASA Astrophysics Data System (ADS)

    Chakravarty, T.; Chowdhury, A.; Ghose, A.; Bhaumik, C.; Balamuralidhar, P.

    2014-03-01

    Telematics form an important technology enabler for intelligent transportation systems. By deploying on-board diagnostic devices, the signatures of vehicle vibration along with its location and time are recorded. Detailed analyses of the collected signatures offer deep insights into the state of the objects under study. Towards that objective, we carried out experiments by deploying telematics device in one of the office bus that ferries employees to office and back. Data is being collected from 3-axis accelerometer, GPS, speed and the time for all the journeys. In this paper, we present initial results of the above exercise by applying statistical methods to derive information through systematic analysis of the data collected over four months. It is demonstrated that the higher order derivative of the measured Z axis acceleration samples display the properties Weibull distribution when the time axis is replaced by the amplitude of such processed acceleration data. Such an observation offers us a method to predict future behaviour where deviations from prediction are classified as context-based aberrations or progressive degradation of the system. In addition we capture the relationship between speed of the vehicle and median of the jerk energy samples using regression analysis. Such results offer an opportunity to develop a robust method to model road-vehicle interaction thereby enabling us to predict such like driving behaviour and condition based maintenance etc.

  19. Ultraminiaturized photovoltaic and radio frequency powered optoelectronic systems for wireless optogenetics.

    PubMed

    Park, Sung Il; Shin, Gunchul; Banks, Anthony; McCall, Jordan G; Siuda, Edward R; Schmidt, Martin J; Chung, Ha Uk; Noh, Kyung Nim; Mun, Jonathan Guo-Han; Rhodes, Justin; Bruchas, Michael R; Rogers, John A

    2015-10-01

    Wireless control and power harvesting systems that operate injectable, cellular-scale optoelectronic components provide important demonstrated capabilities in neuromodulatory techniques such as optogenetics. Here, we report a radio frequency (RF) control/harvesting device that offers dramatically reduced size, decreased weight and improved efficiency compared to previously reported technologies. Combined use of this platform with ultrathin, multijunction, high efficiency solar cells allows for hundred-fold reduction of transmitted RF power, which greatly enhances the wireless coverage. Fabrication involves separate construction of the harvester and the injectable µ-ILEDs. To test whether the presence of the implantable device alters behavior, we implanted one group of wild type mice and compared sociability behavior to unaltered controls. Social interaction experiments followed protocols defined by Silverman et al. with minor modifications. The results presented here demonstrate that miniaturized RF harvesters, and RF control strategies with photovoltaic harvesters can, when combined with injectable µ-ILEDs, offer versatile capabilities in optogenetics. Experimental and modeling studies establish a range of effective operating conditions for these two approaches. Optogenetics studies with social groups of mice demonstrate the utility of these systems. The addition of miniaturized, high performance photovoltaic cells significantly expands the operating range and reduces the required RF power. The platform can offer capabilities to modulate signaling path in the brain region of freely-behaving animals. These suggest its potential for widespread use in neuroscience.

  20. 3D printing of nano- and micro-structures

    NASA Astrophysics Data System (ADS)

    Ramasamy, Mouli; Varadan, Vijay K.

    2016-04-01

    Additive manufacturing or 3D printing techniques are being vigorously investigated as a replacement to the traditional and conventional methods in fabrication to bring forth cost and time effective approaches. Introduction of 3D printing has led to printing micro and nanoscale structures including tissues and organelles, bioelectric sensors and devices, artificial bones and transplants, microfluidic devices, batteries and various other biomaterials. Various microfabrication processes have been developed to fabricate micro components and assemblies at lab scale. 3D Fabrication processes that can accommodate the functional and geometrical requirements to realize complicated structures are becoming feasible through advances in additive manufacturing. This advancement could lead to simpler development mechanisms of novel components and devices exhibiting complex features. For instance, development of microstructure electrodes that can penetrate the epidermis of the skin to collect the bio potential signal may prove very effective than the electrodes that measure signal from the skin's surface. The micro and nanostructures will have to possess extraordinary material and mechanical properties for its dexterity in the applications. A substantial amount of research being pursued on stretchable and flexible devices based on PDMA, textiles, and organic electronics. Despite the numerous advantages these substrates and techniques could solely offer, 3D printing enables a multi-dimensional approach towards finer and complex applications. This review emphasizes the use of 3D printing to fabricate micro and nanostructures for that can be applied for human healthcare.

  1. Room Temperature Silicene Field-Effect Transistors

    NASA Astrophysics Data System (ADS)

    Akinwande, Deji

    Silicene, a buckled Si analogue of graphene, holds significant promise for future electronics beyond traditional CMOS. In our predefined experiments via encapsulated delamination with native electrodes approach, silicene devices exhibit an ambipolar charge transport behavior, corroborating theories on Dirac band in Ag-free silicene. Monolayer silicene device has extracted field-effect mobility within the theoretical expectation and ON/OFF ratio greater than monolayer graphene, while multilayer silicene devices show decreased mobility and gate modulation. Air-stability of silicene devices depends on the number of layers of silicene and intrinsic material structure determined by growth temperature. Few or multi-layer silicene devices maintain their ambipolar behavior for days in contrast to minutes time scale for monolayer counterparts under similar conditions. Multilayer silicene grown at different temperatures below 300oC possess different intrinsic structures and yield different electrical property and air-stability. This work suggests a practical prospect to enable more air-stable silicene devices with layer and growth condition control, which can be leveraged for other air-sensitive 2D materials. In addition, we describe quantum and classical transistor device concepts based on silicene and related buckled materials that exploit the 2D topological insulating phenomenon. The transistor device physics offer the potential for ballistic transport that is robust against scattering and can be employed for both charge and spin transport. This work was supported by the ARO.

  2. Patient-centered activity monitoring in the self-management of chronic health conditions.

    PubMed

    Chiauzzi, Emil; Rodarte, Carlos; DasMahapatra, Pronabesh

    2015-04-09

    As activity tracking devices become smaller, cheaper, and more consumer-accessible, they will be used more extensively across a wide variety of contexts. The expansion of activity tracking and personal data collection offers the potential for patient engagement in the management of chronic diseases. Consumer wearable devices for activity tracking have shown promise in post-surgery recovery in cardiac patients, pulmonary rehabilitation, and activity counseling in diabetic patients, among others. Unfortunately, the data generated by wearable devices is seldom integrated into programmatic self-management chronic disease regimens. In addition, there is lack of evidence supporting sustained use or effects on health outcomes, as studies have primarily focused on establishing the feasibility of monitoring activity and the association of measured activity with short-term benefits. Monitoring devices can make a direct and real-time impact on self-management, but the validity and reliability of measurements need to be established. In order for patients to become engaged in wearable data gathering, key patient-centered issues relating to usefulness in care, motivation, the safety and privacy of information, and clinical integration need to be addressed. Because the successful usage of wearables requires an ability to comprehend and utilize personal health data, the user experience should account for individual differences in numeracy skills and apply evidence-based behavioral science principles to promote continued engagement. Activity monitoring has the potential to engage patients as advocates in their personalized care, as well as offer health care providers real world assessments of their patients' daily activity patterns. This potential will be realized as the voice of the chronic disease patients is accounted for in the design of devices, measurements are validated against existing clinical assessments, devices become part of the treatment 'prescription', behavior change programs are used to engage patients in self-management, and best practices for clinical integration are defined.

  3. Design of a multimedia gateway for mobile devices

    NASA Astrophysics Data System (ADS)

    Hens, Raf; Goeminne, Nico; Van Hoecke, Sofie; Verdickt, Tom; Bouve, Thomas; Gielen, Frank; Demeester, Piet

    2005-03-01

    Although mobile users are currently offered a lot more capabilities on their mobile devices, they still experience some limitations. They can surf the Internet, read their e-mail and receive MMS messages, but they have limited processing power, storage capacity and bandwidth and are limited in their access to peripherals (e.g. printers). We have designed and implemented a multimedia gateway for mobile devices that reduces these limitations. It gives the mobile devices transparent access to high capacity devices connected to the gateway, which is built around a central, modularly extensible server that can run on any PC or home gateway. It manages two sets of modules: one set offering the actual services and another set handling the IP-based wireless interaction with the client applications on the mobile devices. These modules can be added and removed dynamically, offering new services on the fly. Currently services for storage, printing, domotics and playing music are provided. Others can easily be added later on. This paper discusses the architecture and development, the management of modules, the actual services and their benefits. Besides a proprietary implementation, it also looks into OSGi and how both platforms compare to each other, concerning design, architecture, ease of development, functionality, ...

  4. New Magnetic Microactuator Design Based on PDMS Elastomer and MEMS Technologies for Tactile Display.

    PubMed

    Streque, Jeremy; Talbi, Abdelkrim; Pernod, Philippe; Preobrazhensky, Vladimir

    2010-01-01

    Highly efficient tactile display devices must fulfill technical requirements for tactile stimulation, all the while preserving the lightness and compactness needed for handheld operation. This paper focuses on the elaboration of highly integrated magnetic microactuators for tactile display devices. FEM simulation, conception, fabrication, and characterization of these microactuators are presented in this paper. The current demonstrator offers a 4 × 4 flexible microactuator array with a resolution of 2 mm. Each actuator is composed of a Poly (Dimethyl-Siloxane) (PDMS) elastomeric membrane, magnetically actuated by coil-magnet interaction. It represents a proof of concept for fully integrated MEMS tactile devices, with fair actuation forces provided for a power consumption up to 100 mW per microactuator. The prototypes are destined to provide both static and dynamic tactile sensations, with an optimized membrane geometry for actuation frequencies between DC and 350 Hz. On the basis of preliminary experiments, this display device can offer skin stimulations for various tactile stimuli for applications in the fields of Virtual Reality or Human-Computer Interaction (HCI). Moreover, the elastomeric material used in this device and its global compactness offer great advantages in matter of comfort of use and capabilities of integration in haptic devices.

  5. Graphene engineering by neon ion beams

    DOE PAGES

    Iberi, Vighter; Ievlev, Anton V.; Vlassiouk, Ivan; ...

    2016-02-18

    Achieving the ultimate limits of materials and device performance necessitates the engineering of matter with atomic, molecular, and mesoscale fidelity. While common for organic and macromolecular chemistry, these capabilities are virtually absent for 2D materials. In contrast to the undesired effect of ion implantation from focused ion beam (FIB) lithography with gallium ions, and proximity effects in standard e-beam lithography techniques, the shorter mean free path and interaction volumes of helium and neon ions offer a new route for clean, resist free nanofabrication. Furthermore, with the advent of scanning helium ion microscopy, maskless He + and Ne + beam lithographymore » of graphene based nanoelectronics is coming to the forefront. Here, we will discuss the use of energetic Ne ions in engineering graphene devices and explore the mechanical, electromechanical and chemical properties of the ion-milled devices using scanning probe microscopy (SPM). By using SPM-based techniques such as band excitation (BE) force modulation microscopy, Kelvin probe force microscopy (KPFM) and Raman spectroscopy, we demonstrate that the mechanical, electrical and optical properties of the exact same devices can be quantitatively extracted. Additionally, the effect of defects inherent in ion beam direct-write lithography, on the overall performance of the fabricated devices is elucidated.« less

  6. Performance of an SOI Boot-Strapped Full-Bridge MOSFET Driver, Type CHT-FBDR, under Extreme Temperatures

    NASA Technical Reports Server (NTRS)

    Patterson, Richard; Hammoud, Ahmad

    2009-01-01

    Electronic systems designed for use in deep space and planetary exploration missions are expected to encounter extreme temperatures and wide thermal swings. Silicon-based devices are limited in their wide-temperature capability and usually require extra measures, such as cooling or heating mechanisms, to provide adequate ambient temperature for proper operation. Silicon-On-Insulator (SOI) technology, on the other hand, lately has been gaining wide spread use in applications where high temperatures are encountered. Due to their inherent design, SOI-based integrated circuit chips are able to operate at temperatures higher than those of the silicon devices by virtue of reducing leakage currents, eliminating parasitic junctions, and limiting internal heating. In addition, SOI devices provide faster switching, consume less power, and offer improved radiation-tolerance. Very little data, however, exist on the performance of such devices and circuits under cryogenic temperatures. In this work, the performance of an SOI bootstrapped, full-bridge driver integrated circuit was evaluated under extreme temperatures and thermal cycling. The investigations were carried out to establish a baseline on the functionality and to determine suitability of this device for use in space exploration missions under extreme temperature conditions.

  7. Parent Scaffolding of Young Children When Engaged with Mobile Technology

    PubMed Central

    Wood, Eileen; Petkovski, Marjan; De Pasquale, Domenica; Gottardo, Alexandra; Evans, Mary Ann; Savage, Robert S.

    2016-01-01

    Shared parent–child experiences while engaged with an iPadTM were examined to determine if and then how parents interact with their children when using mobile digital devices. In total, 104 parent–child dyads participated in an observation session where parent–child interactions using the touchscreen tablet device were video recorded in order to observe first-hand the supports and exchanges between parent and child (age range 46.21–75.9 months). Results indicate that parents provide a great deal of support to their children while interacting with the touchscreen tablet device including verbal, emotional-verbal, physical and emotional-physical supports. The types of support offered did not differ as a function of parent gender or experience with mobile devices (users versus non-users). Overall, parents rated their own experience engaging with the touchscreen tablet and that of their child’s positively. Additional survey measures assessed parents’ perceptions of their child’s technology use and attitudes regarding optimal ages and conditions for introducing and using technology. Most parents indicated a preference for very early introduction to mobile technologies. Implications of these findings are discussed. PMID:27242603

  8. A High-Voltage Molecular-Engineered Organic Sensitizer-Iron Redox Shuttle Pair: 1.4 V DSSC and 3.3 V SSM-DSSC Devices.

    PubMed

    Rodrigues, Roberta R; Cheema, Hammad; Delcamp, Jared H

    2018-05-04

    The development of high voltage solar cells is an attractive way to use sunlight for solar-to-fuel devices, multijunction solar-to-electric systems, and to power limited-area consumer electronics. By designing a low-oxidation-potential organic dye (RR9)/redox shuttle (Fe(bpy) 3 3+/2+ ) pair for dye-sensitized solar-cell (DSSC) devices, the highest single device photovoltage (1.42 V) has been realized for a DSSC not relying on doped TiO 2 . Additionally, Fe(bpy) 3 3+/2+ offers a robust, readily tunable ligand platform for redox potential tuning. RR9 can be regenerated with a low driving force (190 mV), and by utilizing the RR9/Fe(bpy) 3 3+/2+ redox shuttle pair in a subcell for a sequential series multijunction (SSM)-DSSC system, one of the highest known three subcell photovoltage was attained for any solar-cell technology (3.34 V, >1.0 V per subcell). © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Parent Scaffolding of Young Children When Engaged with Mobile Technology.

    PubMed

    Wood, Eileen; Petkovski, Marjan; De Pasquale, Domenica; Gottardo, Alexandra; Evans, Mary Ann; Savage, Robert S

    2016-01-01

    Shared parent-child experiences while engaged with an iPad(TM) were examined to determine if and then how parents interact with their children when using mobile digital devices. In total, 104 parent-child dyads participated in an observation session where parent-child interactions using the touchscreen tablet device were video recorded in order to observe first-hand the supports and exchanges between parent and child (age range 46.21-75.9 months). Results indicate that parents provide a great deal of support to their children while interacting with the touchscreen tablet device including verbal, emotional-verbal, physical and emotional-physical supports. The types of support offered did not differ as a function of parent gender or experience with mobile devices (users versus non-users). Overall, parents rated their own experience engaging with the touchscreen tablet and that of their child's positively. Additional survey measures assessed parents' perceptions of their child's technology use and attitudes regarding optimal ages and conditions for introducing and using technology. Most parents indicated a preference for very early introduction to mobile technologies. Implications of these findings are discussed.

  10. The effect of extended sensory range via the EyeCane sensory substitution device on the characteristics of visionless virtual navigation.

    PubMed

    Maidenbaum, Shachar; Levy-Tzedek, Shelly; Chebat, Daniel Robert; Namer-Furstenberg, Rinat; Amedi, Amir

    2014-01-01

    Mobility training programs for helping the blind navigate through unknown places with a White-Cane significantly improve their mobility. However, what is the effect of new assistive technologies, offering more information to the blind user, on the underlying premises of these programs such as navigation patterns? We developed the virtual-EyeCane, a minimalistic sensory substitution device translating single-point-distance into auditory cues identical to the EyeCane's in the real world. We compared performance in virtual environments when using the virtual-EyeCane, a virtual-White-Cane, no device and visual navigation. We show that the characteristics of virtual-EyeCane navigation differ from navigation with a virtual-White-Cane or no device, and that virtual-EyeCane users complete more levels successfully, taking shorter paths and with less collisions than these groups, and we demonstrate the relative similarity of virtual-EyeCane and visual navigation patterns. This suggests that additional distance information indeed changes navigation patterns from virtual-White-Cane use, and brings them closer to visual navigation.

  11. Emerging Trends in Phosphorene Fabrication towards Next Generation Devices

    PubMed Central

    Dhanabalan, Sathish Chander; Ponraj, Joice Sophia; Guo, Zhinan

    2017-01-01

    The challenge of science and technology is to design and make materials that will dominate the future of our society. In this context, black phosphorus has emerged as a new, intriguing two‐dimensional (2D) material, together with its monolayer, which is referred to as phosphorene. The exploration of this new 2D material demands various fabrication methods to achieve potential applications— this demand motivated this review. This article is aimed at supplementing the concrete understanding of existing phosphorene fabrication techniques, which forms the foundation for a variety of applications. Here, the major issue of the degradation encountered in realizing devices based on few‐layered black phosphorus and phosphorene is reviewed. The prospects of phosphorene in future research are also described by discussing its significance and explaining ways to advance state‐of‐art of phosphorene‐based devices. In addition, a detailed presentation on the demand for future studies to promote well‐systemized fabrication methods towards large‐area, high‐yield and perfectly protected phosphorene for the development of reliable devices in optoelectronic applications and other areas is offered. PMID:28638779

  12. Nonvisual Adaptive Devices for Measuring Insulin.

    ERIC Educational Resources Information Center

    Cleary, M. E.; Hamilton, J. E.

    1993-01-01

    This article presents information on nonvisual adaptive devices for measuring insulin and offers some suggestions for rehabilitation professionals who instruct and supervise clients with diabetes and visual impairment in the use of these devices. (Author)

  13. On the Properties and Design of Organic Light-Emitting Devices

    NASA Astrophysics Data System (ADS)

    Erickson, Nicholas C.

    Organic light-emitting devices (OLEDs) are attractive for use in next-generation display and lighting technologies. In display applications, OLEDs offer a wide emission color gamut, compatibility with flexible substrates, and high power efficiencies. In lighting applications, OLEDs offer attractive features such as broadband emission, high-performance, and potential compatibility with low-cost manufacturing methods. Despite recent demonstrations of near unity internal quantum efficiencies (photons out per electron in), OLED adoption lags conventional technologies, particularly in large-area displays and general lighting applications. This thesis seeks to understand the optical and electronic properties of OLED materials and device architectures which lead to not only high peak efficiency, but also reduced device complexity, high efficiency under high excitation, and optimal white-light emission. This is accomplished through the careful manipulation of organic thin film compositions fabricated via vacuum thermal evaporation, and the introduction of a novel device architecture, the graded-emissive layer (G-EML). This device architecture offers a unique platform to study the electronic properties of varying compositions of organic semiconductors and the resulting device performance. This thesis also introduces an experimental technique to measure the spatial overlap of electrons and holes within an OLED's emissive layer. This overlap is an important parameter which is affected by the choice of materials and device design, and greatly impacts the operation of the OLED at high excitation densities. Using the G-EML device architecture, OLEDs with improved efficiency characteristics are demonstrated, achieving simultaneously high brightness and high efficiency.

  14. Piezoelectric Bolt Breakers and Bolt Fatigue Testers

    NASA Technical Reports Server (NTRS)

    Sherrit, Stewart; Badescu, Mircea; Bar-Cohen, Yoseph; Barengoltz, Jack; Heckman, Vanessa

    2008-01-01

    A proposed family of devices for inducing fatigue in bolts in order to break the bolts would incorporate piezoelectric actuators into resonant fixtures as in ultrasonic/ sonic drills/corers and similar devices described in numerous prior NASA Tech Briefs articles. These devices were originally intended primarily for use as safer, more-reliable, more-versatile alternatives to explosive bolts heretofore used to fasten spacecraft structures that must subsequently be separated from each other quickly on command during flight. On Earth, these devices could be used for accelerated fatigue testing of bolts. Fatigue theory suggests that a bolt subjected to both a constant-amplitude dynamic (that is, oscillatory) stress and a static tensile stress below the ultimate strength of the bolt material will fail faster than will a bolt subjected to only the dynamic stress. This suggestion would be applied in a device of the proposed type. The device would be designed so that the device and the bolt to be fatigue-tested or broken would be integral parts of an assembly (see figure). The static tension in the tightened bolt would apply not only the clamping force to hold the joined structures (if any) together but also the compression necessary for proper operation of the piezoelectric actuators as parts of a resonant structural assembly. The constant-amplitude dynamic stress would be applied to the bolt by driving the piezoelectric actuators with a sinusoidal voltage at the resonance frequency of longitudinal vibration of the assembly. The amplitude of the excitation would be made large enough so that the vibration would induce fatigue in the bolt within an acceptably short time. In the spacecraft applications or in similar terrestrial structural-separation applications, devices of the proposed type would offer several advantages over explosive bolts: Unlike explosive bolts, the proposed devices would be reusable, could be tested before final use, and would not be subject to catastrophic misfire. In fatigue-testing applications, devices of the proposed type would offer advantages of compactness and low cost, relative to conventional fatigue- testing apparatuses. In both structural- separation and fatigue-testing applications, bolts to be broken or tested could be instrumented with additional ultrasonic transducers for monitoring of pertinent physical properties and of fatigue failure processes.

  15. Cavity Resonator Wireless Power Transfer System for Freely Moving Animal Experiments.

    PubMed

    Mei, Henry; Thackston, Kyle A; Bercich, Rebecca A; Jefferys, John G R; Irazoqui, Pedro P

    2017-04-01

    The goal of this paper is to create a large wireless powering arena for powering small devices implanted in freely behaving rodents. We design a cavity resonator based wireless power transfer (WPT) system and utilize our previously developed optimal impedance matching methodology to achieve effective WPT performance for operating sophisticated implantable devices, made with miniature receive coils (<8 mm in diameter), within a large volume (dimensions: 60.96 cm × 60.96 cm × 30 cm). We provide unique cavity design and construction methods which maintains electromagnetic performance of the cavity while promoting its utility as a large animal husbandry environment. In addition, we develop a biaxial receive resonator system to address device orientation insensitivity within the cavity environment. Functionality is demonstrated with chronic experiments involving rats implanted with our custom designed bioelectric recording device. We demonstrate an average powering fidelity of 93.53% over nine recording sessions across nine weeks, indicating nearly continuous device operation for a freely behaving rat within the large cavity resonator space. We have developed and demonstrated a cavity resonator based WPT system for long term experiments involving freely behaving small animals. This cavity resonator based WPT system offers an effective and simple method for wirelessly powering miniaturized devices implanted in freely moving small animals within the largest space.

  16. Optical rectification using geometrical field enhancement in gold nano-arrays

    NASA Astrophysics Data System (ADS)

    Piltan, S.; Sievenpiper, D.

    2017-11-01

    Conversion of photons to electrical energy has a wide variety of applications including imaging, solar energy harvesting, and IR detection. A rectenna device consists of an antenna in addition to a rectifying element to absorb the incident radiation within a certain frequency range. We designed, fabricated, and measured an optical rectifier taking advantage of asymmetrical field enhancement for forward and reverse currents due to geometrical constraints. The gold nano-structures as well as the geometrical parameters offer enhanced light-matter interaction at 382 THz. Using the Taylor expansion of the time-dependent current as a function of the external bias and oscillating optical excitation, we obtained responsivities close to quantum limit of operation. This geometrical approach can offer an efficient, broadband, and scalable solution for energy conversion and detection in the future.

  17. Hierarchically nanostructured materials for sustainable environmental applications

    PubMed Central

    Ren, Zheng; Guo, Yanbing; Liu, Cai-Hong; Gao, Pu-Xian

    2013-01-01

    This review presents a comprehensive overview of the hierarchical nanostructured materials with either geometry or composition complexity in environmental applications. The hierarchical nanostructures offer advantages of high surface area, synergistic interactions, and multiple functionalities toward water remediation, biosensing, environmental gas sensing and monitoring as well as catalytic gas treatment. Recent advances in synthetic strategies for various hierarchical morphologies such as hollow spheres and urchin-shaped architectures have been reviewed. In addition to the chemical synthesis, the physical mechanisms associated with the materials design and device fabrication have been discussed for each specific application. The development and application of hierarchical complex perovskite oxide nanostructures have also been introduced in photocatalytic water remediation, gas sensing, and catalytic converter. Hierarchical nanostructures will open up many possibilities for materials design and device fabrication in environmental chemistry and technology. PMID:24790946

  18. Hierarchically Nanostructured Materials for Sustainable Environmental Applications

    NASA Astrophysics Data System (ADS)

    Ren, Zheng; Guo, Yanbing; Liu, Cai-Hong; Gao, Pu-Xian

    2013-11-01

    This article presents a comprehensive overview of the hierarchical nanostructured materials with either geometry or composition complexity in environmental applications. The hierarchical nanostructures offer advantages of high surface area, synergistic interactions and multiple functionalities towards water remediation, environmental gas sensing and monitoring as well as catalytic gas treatment. Recent advances in synthetic strategies for various hierarchical morphologies such as hollow spheres and urchin-shaped architectures have been reviewed. In addition to the chemical synthesis, the physical mechanisms associated with the materials design and device fabrication have been discussed for each specific application. The development and application of hierarchical complex perovskite oxide nanostructures have also been introduced in photocatalytic water remediation, gas sensing and catalytic converter. Hierarchical nanostructures will open up many possibilities for materials design and device fabrication in environmental chemistry and technology.

  19. Multiplexing 200 spatial modes with a single hologram

    NASA Astrophysics Data System (ADS)

    Rosales-Guzmán, Carmelo; Bhebhe, Nkosiphile; Mahonisi, Nyiku; Forbes, Andrew

    2017-11-01

    The on-demand tailoring of light's spatial shape is of great relevance in a wide variety of research areas. Computer-controlled devices, such as spatial light modulators (SLMs) or digital micromirror devices, offer a very accurate, flexible and fast holographic means to this end. Remarkably, digital holography affords the simultaneous generation of multiple beams (multiplexing), a tool with numerous applications in many fields. Here, we provide a self-contained tutorial on light beam multiplexing. Through the use of several examples, the readers will be guided step by step in the process of light beam shaping and multiplexing. Additionally, we provide a quantitative analysis on the multiplexing capabilities of SLMs to assess the maximum number of beams that can be multiplexed on a single SLM, showing approximately 200 modes on a single hologram.

  20. Possibility of controlling nonregulated prices in the electricity market by means of varying the parameters of a power system

    NASA Astrophysics Data System (ADS)

    Vaskovskaya, T. A.

    2014-12-01

    This paper offers a new approach to the analysis of price signals from the wholesale electricity and capacity market that is based on the analysis of the influence exerted by input data used in the problem of optimization of the power system operating conditions, namely: parameters of a power grid and power-receiving equipment that might vary under the effect of control devices. It is shown that it would be possible to control nonregulated prices for electricity in the wholesale electricity market by varying the parameters of control devices and energy-receiving equipment. An increase in the effectiveness of power transmission and the cost-effective use of fuel-and-energy resources (energy saving) can become an additional effect of controlling the nonregulated prices.

  1. Realization of spin wave switch for data processing

    NASA Astrophysics Data System (ADS)

    Balinskiy, M.; Chiang, H.; Khitun, A.

    2018-05-01

    In this work, experimental data on a spin wave switch based on spin wave interference is reported. The switch is a three terminal device where spin wave propagation between the source and the drain is modulated by the control spin wave signal. The prototype is a micrometer scale device based on Y3Fe2(FeO4)3 film. The output characteristics show the oscillation of the output spin wave signal as a function of the phase difference between the source and the drain spin wave signals. The On/Off ratio of the prototype exceeds 20 dB at room temperature. The utilization of phase in addition to amplitude for information encoding offers an innovative route towards multi-state logic circuits. The advantages and shortcomings of spin wave switches are also discussed.

  2. Enhanced hybrid TV platform with multiscreen, advanced EPG and recommendation enablers

    NASA Astrophysics Data System (ADS)

    Kovacik, Tomas; Bencel, Rastislav; Mato, Jan; Bronis, Roman; Truchly, Peter; Kotuliak, Ivan

    2017-05-01

    TV watching dramatically changes with introduction of new technologies such as Internet-connected TVs, enriched digital broadcasting (DVB), on-demand content, additional programme information, mobile phones and tablets enabling multiscreen functions etc that offer added values to content consumers. In this paper we propose modular advanced TV platform and its enablers enhancing TV watching. They allow users to receive aside of EPG also additional information about broadcasted content, to be reminded of requested programme, to utilize recommendation and search features, thanks to multiscreen functionality to allow users to take watched content with them or transfer it onto another device. The modularity of the platform allows new features to be added in future.

  3. Graphene-Nanodiamond Heterostructures and their application to High Current Devices

    PubMed Central

    Zhao, Fang; Vrajitoarea, Andrei; Jiang, Qi; Han, Xiaoyu; Chaudhary, Aysha; Welch, Joseph O.; Jackman, Richard B.

    2015-01-01

    Graphene on hydrogen terminated monolayer nanodiamond heterostructures provides a new way to improve carrier transport characteristics of the graphene, offering up to 60% improvement when compared with similar graphene on SiO2/Si substrates. These heterostructures offers excellent current-carrying abilities whilst offering the prospect of a fast, low cost and easy methodology for device applications. The use of ND monolayers is also a compatible technology for the support of large area graphene films. The nature of the C-H bonds between graphene and H-terminated NDs strongly influences the electronic character of the heterostructure, creating effective charge redistribution within the system. Field effect transistors (FETs) have been fabricated based on this novel herterostructure to demonstrate device characteristics and the potential of this approach. PMID:26350107

  4. Performance of MEMS Silicon Oscillator, ASFLM1, under Wide Operating Temperature Range

    NASA Technical Reports Server (NTRS)

    Patterson, Richard L.; Hammoud, Ahmad

    2008-01-01

    Over the last few years, MEMS (Micro-Electro-Mechanical Systems) resonator-based oscillators began to be offered as commercial-off-the-shelf (COTS) parts by a few companies [1-2]. These quartz-free, miniature silicon devices could compete with the traditional crystal oscillators in providing the timing (clock function) for many digital and analog electronic circuits. They provide stable output frequency, offer great tolerance to shock and vibration, and are immune to electro-static discharge [1-2]. In addition, they are encapsulated in compact lead-free packages, cover a wide frequency range (1 MHz to 125 MHz), and are specified, depending on the grade, for extended temperature operation from -40 C to +85 C. The small size of the MEMS oscillators along with their reliability and thermal stability make them candidates for use in space exploration missions. Limited data, however, exist on the performance and reliability of these devices under operation in applications where extreme temperatures or thermal cycling swings, which are typical of space missions, are encountered. This report presents the results of the work obtained on the evaluation of an ABRACON Corporation MEMS silicon oscillator chip, type ASFLM1, under extreme temperatures.

  5. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment.

    PubMed

    Milanovic, Jovana Z; Milanovic, Predrag; Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source "OpenPhControl" software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device's utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary.

  6. 47 CFR 2.1204 - Import conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... generations of a particular model under development are considered to be separate devices. (4) The radio... particular model under development are considered to be separate devices. (5) The radio frequency device is... offered for sale or marketed. (9) The radio frequency device is a medical implant transmitter inserted in...

  7. 47 CFR 2.1204 - Import conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... generations of a particular model under development are considered to be separate devices. (4) The radio... particular model under development are considered to be separate devices. (5) The radio frequency device is... offered for sale or marketed. (9) The radio frequency device is a medical implant transmitter inserted in...

  8. Understanding the biological responses of nanostructured metals and surfaces

    NASA Astrophysics Data System (ADS)

    Lowe, Terry C.; Reiss, Rebecca A.

    2014-08-01

    Metals produced by Severe Plastic Deformation (SPD) offer distinct advantages for medical applications such as orthopedic devices, in part because of their nanostructured surfaces. We examine the current theoretical foundations and state of knowledge for nanostructured biomaterials surface optimization within the contexts that apply to bulk nanostructured metals, differentiating how their microstructures impact osteogenesis, in particular, for Ultrafine Grained (UFG) titanium. Then we identify key gaps in the research to date, pointing out areas which merit additional focus within the scientific community. For example, we highlight the potential of next-generation DNA sequencing techniques (NGS) to reveal gene and non-coding RNA (ncRNA) expression changes induced by nanostructured metals. While our understanding of bio-nano interactions is in its infancy, nanostructured metals are already being marketed or developed for medical devices such as dental implants, spinal devices, and coronary stents. Our ability to characterize and optimize the biological response of cells to SPD metals will have synergistic effects on advances in materials, biological, and medical science.

  9. Study on the photocatalytic reaction kinetics in a TiO2 nanoparticles coated microreactor integrated microfluidics device.

    PubMed

    Liu, Ai-Lin; Li, Zhong-Qiu; Wu, Zeng-Qiang; Xia, Xing-Hua

    2018-05-15

    For study of the photocatalytic reaction kinetics in a confined microsystem, a photocatalysis microreactor integrated on a microfluidic device has been fabricated using an on-line UV/vis detector. The performance of the photocatalysis microreactor is evaluated by the photocatalytic degradation of Rhodamine B chosen as model target by using commercial titanium dioxide (Degussa P25, TiO 2 ) nanoparticles as a photocatalyst. Results show that the photocatalytic reaction occurs via the Langmuir-Hinshelwood mechanism and the photocatalysis kinetics in the confined microsystem (r = 0.359 min -1 ) is about 10 times larger than that in macrosystem (r = 0.033 min -1 ). In addition, the photocatalysis activity of the immobilized TiO 2 nanoparticles in the microreactor exhibits good stability under flowing conditions. The present microchip device offers an interesting platform for screening of photocatalysts and exploration of photocatalysis mechanisms and kinetics. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Enhancement-mode two-channel triple quantum dot from an undoped Si/Si 0.8Ge 0.2 quantum well hetero-structure

    DOE PAGES

    Studenikin, S. A.; Gaudreau, L.; Kataoka, K.; ...

    2018-06-04

    Here, we demonstrate coupled triple dot operation and charge sensing capability for the recently introduced quantum dot technology employing undoped Si/Si 0.8Ge 0.2 hetero-structures which also incorporate a single metal-gate layer to simplify fabrication. Si/SiGe hetero-structures with a Ge concentration of 20% rather than the more usual 30% typically encountered offer higher electron mobility. The devices consist of two in-plane parallel electron channels that host a double dot in one channel and a single dot in the other channel. In a device where the channels are sufficiently close a triple dot in a triangular configuration is induced leading to regionsmore » in the charge stability diagram where three charge-addition lines of different slope approach each other and anti-cross. In a device where the channels are further apart, the single dot charge-senses the double dot with relative change of ~2% in the sensor current.« less

  11. Enhancement-mode two-channel triple quantum dot from an undoped Si/Si 0.8Ge 0.2 quantum well hetero-structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Studenikin, S. A.; Gaudreau, L.; Kataoka, K.

    Here, we demonstrate coupled triple dot operation and charge sensing capability for the recently introduced quantum dot technology employing undoped Si/Si 0.8Ge 0.2 hetero-structures which also incorporate a single metal-gate layer to simplify fabrication. Si/SiGe hetero-structures with a Ge concentration of 20% rather than the more usual 30% typically encountered offer higher electron mobility. The devices consist of two in-plane parallel electron channels that host a double dot in one channel and a single dot in the other channel. In a device where the channels are sufficiently close a triple dot in a triangular configuration is induced leading to regionsmore » in the charge stability diagram where three charge-addition lines of different slope approach each other and anti-cross. In a device where the channels are further apart, the single dot charge-senses the double dot with relative change of ~2% in the sensor current.« less

  12. Protein stability in pulmonary drug delivery via nebulization.

    PubMed

    Hertel, Sebastian P; Winter, Gerhard; Friess, Wolfgang

    2015-10-01

    Protein inhalation is a delivery route which offers high potential for direct local lung application of proteins. Liquid formulations are usually available in early stages of biopharmaceutical development and nebulizers are the device of choice for atomization avoiding additional process steps like drying and enabling fast progression to clinical trials. While some proteins were proven to remain stable throughout aerosolization e.g. DNase, many biopharmaceuticals are more susceptible towards the stresses encountered during nebulization. The main reason for protein instability is unfolding and aggregation at the air-liquid interface, a problem which is of particular challenge in the case of ultrasound and jet nebulizers due to recirculation of much of the generated droplets. Surfactants are an important formulation component to protect the sensitive biomolecules. A second important challenge is warming of ultrasound and vibrating mesh devices, which can be overcome by overfilling, precooled solutions or cooling of the reservoir. Ultimately, formulation development has to go hand in hand with device evaluation. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Biofabrication of customized bone grafts by combination of additive manufacturing and bioreactor knowhow.

    PubMed

    Costa, Pedro F; Vaquette, Cédryck; Baldwin, Jeremy; Chhaya, Mohit; Gomes, Manuela E; Reis, Rui L; Theodoropoulos, Christina; Hutmacher, Dietmar W

    2014-09-01

    This study reports on an original concept of additive manufacturing for the fabrication of tissue engineered constructs (TEC), offering the possibility of concomitantly manufacturing a customized scaffold and a bioreactor chamber to any size and shape. As a proof of concept towards the development of anatomically relevant TECs, this concept was utilized for the design and fabrication of a highly porous sheep tibia scaffold around which a bioreactor chamber of similar shape was simultaneously built. The morphology of the bioreactor/scaffold device was investigated by micro-computed tomography and scanning electron microscopy confirming the porous architecture of the sheep tibiae as opposed to the non-porous nature of the bioreactor chamber. Additionally, this study demonstrates that both the shape, as well as the inner architecture of the device can significantly impact the perfusion of fluid within the scaffold architecture. Indeed, fluid flow modelling revealed that this was of significant importance for controlling the nutrition flow pattern within the scaffold and the bioreactor chamber, avoiding the formation of stagnant flow regions detrimental for in vitro tissue development. The bioreactor/scaffold device was dynamically seeded with human primary osteoblasts and cultured under bi-directional perfusion for two and six weeks. Primary human osteoblasts were observed homogenously distributed throughout the scaffold, and were viable for the six week culture period. This work demonstrates a novel application for additive manufacturing in the development of scaffolds and bioreactors. Given the intrinsic flexibility of the additive manufacturing technology platform developed, more complex culture systems can be fabricated which would contribute to the advances in customized and patient-specific tissue engineering strategies for a wide range of applications.

  14. 3D printing of tablets using inkjet with UV photoinitiation.

    PubMed

    Clark, Elizabeth A; Alexander, Morgan R; Irvine, Derek J; Roberts, Clive J; Wallace, Martin J; Sharpe, Sonja; Yoo, Jae; Hague, Richard J M; Tuck, Chris J; Wildman, Ricky D

    2017-08-30

    Additive manufacturing (AM) offers significant potential benefits in the field of drug delivery and pharmaceutical/medical device manufacture. Of AM processes, 3D inkjet printing enables precise deposition of a formulation, whilst offering the potential for significant scale up or scale out as a manufacturing platform. This work hypothesizes that suitable solvent based ink formulations can be developed that allow the production of solid dosage forms that meet the standards required for pharmaceutical tablets, whilst offering a platform for flexible and personalized manufacture. We demonstrate this using piezo-activated inkjetting to 3D print ropinirole hydrochloride. The tablets produced consist of a cross-linked poly(ethylene glycol diacrylate) (PEGDA) hydrogel matrix containing the drug, photoinitiated in a low oxygen environment using an aqueous solution of Irgacure 2959. At a Ropinirole HCl loading of 0.41mg, drug release from the tablet is shown to be Fickian. Raman and IR spectroscopy indicate a high degree of cross-linking and formation of an amorphous solid dispersion. This is the first publication of a UV inkjet 3D printed tablet. Consequently, this work opens the possibility for the translation of scalable, high precision and bespoke ink-jet based additive manufacturing to the pharmaceutical sector. Copyright © 2017. Published by Elsevier B.V.

  15. Self-assembly strategies for the synthesis of functional nanostructured materials

    NASA Astrophysics Data System (ADS)

    Perego, M.; Seguini, G.

    2016-06-01

    Self-assembly is the autonomous organization of components into patterns or structures without human intervention. This is the approach followed by nature to generate living cells and represents one of the practical strategies to fabricate ensembles of nanostructures. In static self-assembly the formation of ordered structures could require energy but once formed the structures are stable. The introduction of additional regular features in the environment could be used to template the self-assembly guiding the organization of the components and determining the final structure they form. In this regard self-assembly of block copolymers represents a potent platform for fundamental studies at the nanoscale and for application-driven investigation as a tool to fabricate functional nanostructured materials. Block copolymers can hierarchically assemble into chemically distinct domains with size and periodicity on the order of 10nm or below, offering a potentially inexpensive route to generate large-area nanostructured materials. The final structure characteristics of these materials are dictated by the properties of the elementary block copolymers, like chain length, volume fraction or degree of block incompatibility. Modern synthetic chemistry offers the possibility to design these macromolecules with very specific length scales and geometries, directly embodying in the block copolymers the code that drives their self- assembling process. The understanding of the kinetics and thermodynamics of the block copolymer self-assembly process in the bulk phase as well as in thin films represents a fundamental prerequisite toward the exploitation of these materials. Incorporating block copolymer into device fabrication procedures or directly into devices, as active elements, will lead to the development of a new generation of devices fabricated using the fundamental law of nature to our advantage in order to minimize cost and power consumption in the fabrication process. Moreover the capability to precisely organize these nano-objects on appropriate substrates is the key point to support the technological development of new device concepts with predictable characteristics based on these nano-materials. In the next coming years this area of research, at the intersection between fundamental science and technology, is expected to disclose additional insights in the physics of the self-assembly process and to delineate unforeseen applications for these exciting materials.

  16. Three-dimensional femtosecond laser processing for lab-on-a-chip applications

    NASA Astrophysics Data System (ADS)

    Sima, Felix; Sugioka, Koji; Vázquez, Rebeca Martínez; Osellame, Roberto; Kelemen, Lóránd; Ormos, Pal

    2018-02-01

    The extremely high peak intensity associated with ultrashort pulse width of femtosecond laser allows us to induce nonlinear interaction such as multiphoton absorption and tunneling ionization with materials that are transparent to the laser wavelength. More importantly, focusing the femtosecond laser beam inside the transparent materials confines the nonlinear interaction only within the focal volume, enabling three-dimensional (3D) micro- and nanofabrication. This 3D capability offers three different schemes, which involve undeformative, subtractive, and additive processing. The undeformative processing preforms internal refractive index modification to construct optical microcomponents including optical waveguides. Subtractive processing can realize the direct fabrication of 3D microfluidics, micromechanics, microelectronics, and photonic microcomponents in glass. Additive processing represented by two-photon polymerization enables the fabrication of 3D polymer micro- and nanostructures for photonic and microfluidic devices. These different schemes can be integrated to realize more functional microdevices including lab-on-a-chip devices, which are miniaturized laboratories that can perform reaction, detection, analysis, separation, and synthesis of biochemical materials with high efficiency, high speed, high sensitivity, low reagent consumption, and low waste production. This review paper describes the principles and applications of femtosecond laser 3D micro- and nanofabrication for lab-on-a-chip applications. A hybrid technique that promises to enhance functionality of lab-on-a-chip devices is also introduced.

  17. Requirements for maintaining cryogenic propellants during planetary surface stays

    NASA Technical Reports Server (NTRS)

    Riccio, Joseph R.; Schoenberg, Richard J.

    1991-01-01

    Potential impacts on the planetary surface system infrastructure resulting from the use of liquid hydrogen and oxygen propellants for a stage and half lander are discussed. Particular attention is given to techniques which can be incorporated into the surface infrastructure and/or the vehicle to minimize the impact resulting from the use of these cryogens. Methods offered for reducing cryogenic propellant boiloff include modification of the lander to accommodate boiloff, incorporation of passive thermal control devices to the lander, addition of active propellant management, and use of alternative propellants.

  18. Cost-effective optical switch matrix for microwave phased-array

    NASA Technical Reports Server (NTRS)

    Pan, J. J.; Chia, S. L.; Li, W. Z.; Grove, C. H.

    1991-01-01

    An all-fiber (6x6) optical shutter switch matrix with the control system for microwave phased array has been demonstrated. The device offers the advantages of integrated configuration, low cost, low power consumption, small size, and light weight. The maximum extinction ratio (among 36 individual pixel) of this switch matrix at 840 nm is 24.2 dB, and the switching time is less than 120 microsec. In addition to phased array application, this low cost switch matrix is extremely attractive for fiber optic switching networks.

  19. WindWaveFloat (WWF): Final Scientific Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alla Weinstein; Roddier, Dominique; Banister, Kevin

    2012-03-30

    Principle Power Inc. and National Renewable Energy Lab (NREL) have completed a contract to assess the technical and economic feasibility of integrating wave energy converters into the WindFloat, resulting in a new concept called the WindWaveFloat (WWF). The concentration of several devices on one platform could offer a potential for both economic and operational advantages. Wind and wave energy converters can share the electrical cable and power transfer equipment to transport the electricity to shore. Access to multiple generation devices could be simplified, resulting in cost saving at the operational level. Overall capital costs may also be reduced, provided thatmore » the design of the foundation can be adapted to multiple devices with minimum modifications. Finally, the WindWaveFloat confers the ability to increase energy production from individual floating support structures, potentially leading to a reduction in levelized energy costs, an increase in the overall capacity factor, and greater stability of the electrical power delivered to the grid. The research conducted under this grant investigated the integration of several wave energy device types into the WindFloat platform. Several of the resulting system designs demonstrated technical feasibility, but the size and design constraints of the wave energy converters (technical and economic) make the WindWaveFloat concept economically unfeasible at this time. Not enough additional generation could be produced to make the additional expense associated with wave energy conversion integration into the WindFloat worthwhile.« less

  20. Acoustically enhanced microfluidic mixer to synthesize highly uniform nanodrugs without the addition of stabilizers.

    PubMed

    Le, Nguyen Hoai An; Van Phan, Hoang; Yu, Jiaqi; Chan, Hak-Kim; Neild, Adrian; Alan, Tuncay

    2018-01-01

    This article presents an acoustically enhanced microfluidic mixer to generate highly uniform and ultra-fine nanoparticles, offering significant advantages over conventional liquid antisolvent techniques. The method employed a 3D microfluidic geometry whereby two different phases - solvent and antisolvent - were introduced at either side of a 1 μm thick resonating membrane, which contained a through-hole. The vibration of the membrane rapidly and efficiently mixed the two phases, at the location of the hole, leading to the formation of nanoparticles. The versatility of the device was demonstrated by synthesizing budesonide (a common asthma drug) with a mean diameter of 135.7 nm and a polydispersity index of 0.044. The method offers a 40-fold reduction in the size of synthesized particles combined with a substantial improvement in uniformity, achieved without the need of stabilizers.

  1. Techniques for Connecting Superconducting Thin Films

    NASA Technical Reports Server (NTRS)

    Mester, John; Gwo, Dz-Hung

    2006-01-01

    Several improved techniques for connecting superconducting thin films on substrates have been developed. The techniques afford some versatility for tailoring the electronic and mechanical characteristics of junctions between superconductors in experimental electronic devices. The techniques are particularly useful for making superconducting or alternatively normally conductive junctions (e.g., Josephson junctions) between patterned superconducting thin films in order to exploit electron quantum-tunneling effects. The techniques are applicable to both low-Tc and high-Tc superconductors (where Tc represents the superconducting- transition temperature of a given material), offering different advantages for each. Most low-Tc superconductors are metallic, and heretofore, connections among them have been made by spot welding. Most high-Tc superconductors are nonmetallic and cannot be spot welded. These techniques offer alternatives to spot welding of most low-Tc superconductors and additional solutions to problems of connecting most high-Tc superconductors.

  2. Innovation and the medical devices Farady partnership.

    PubMed

    Tavakoli, M; Dunkerton, S B

    2005-06-01

    Demand for development of new generation medical devices has led many governments to support medical-sector research. In the United Kingdom, the Medical Devices Faraday Partnership was created to establish a collaborative network that would enhance the transfer of good ideas into new products and processes. The services it offers medical device manufacturers are outlined here.

  3. Reflective lens-free imaging on high-density silicon microelectrode arrays for monitoring and evaluation of in vitro cardiac contractility

    PubMed Central

    Pauwelyn, Thomas; Stahl, Richard; Mayo, Lakyn; Zheng, Xuan; Lambrechts, Andy; Janssens, Stefan; Lagae, Liesbet; Reumers, Veerle; Braeken, Dries

    2018-01-01

    The high rate of drug attrition caused by cardiotoxicity is a major challenge for drug development. Here, we developed a reflective lens-free imaging (RLFI) approach to non-invasively record in vitro cell deformation in cardiac monolayers with high temporal (169 fps) and non-reconstructed spatial resolution (352 µm) over a field-of-view of maximally 57 mm2. The method is compatible with opaque surfaces and silicon-based devices. Further, we demonstrated that the system can detect the impairment of both contractility and fast excitation waves in cardiac monolayers. Additionally, the RLFI device was implemented on a CMOS-based microelectrode array to retrieve multi-parametric information of cardiac cells, thereby offering more in-depth analysis of drug-induced (cardiomyopathic) effects for preclinical cardiotoxicity screening applications. PMID:29675322

  4. Droplet Breakup in Expansion-contraction Microchannels

    PubMed Central

    Zhu, Pingan; Kong, Tiantian; Lei, Leyan; Tian, Xiaowei; Kang, Zhanxiao; Wang, Liqiu

    2016-01-01

    We investigate the influences of expansion-contraction microchannels on droplet breakup in capillary microfluidic devices. With variations in channel dimension, local shear stresses at the injection nozzle and focusing orifice vary, significantly impacting flow behavior including droplet breakup locations and breakup modes. We observe transition of droplet breakup location from focusing orifice to injection nozzle, and three distinct types of recently-reported tip-multi-breaking modes. By balancing local shear stresses and interfacial tension effects, we determine the critical condition for breakup location transition, and characterize the tip-multi-breaking mode quantitatively. In addition, we identify the mechanism responsible for the periodic oscillation of inner fluid tip in tip-multi-breaking mode. Our results offer fundamental understanding of two-phase flow behaviors in expansion-contraction microstructures, and would benefit droplet generation, manipulation and design of microfluidic devices. PMID:26899018

  5. An ingestible bacterial-electronic system to monitor gastrointestinal health.

    PubMed

    Mimee, Mark; Nadeau, Phillip; Hayward, Alison; Carim, Sean; Flanagan, Sarah; Jerger, Logan; Collins, Joy; McDonnell, Shane; Swartwout, Richard; Citorik, Robert J; Bulović, Vladimir; Langer, Robert; Traverso, Giovanni; Chandrakasan, Anantha P; Lu, Timothy K

    2018-05-25

    Biomolecular monitoring in the gastrointestinal tract could offer rapid, precise disease detection and management but is impeded by access to the remote and complex environment. Here, we present an ingestible micro-bio-electronic device (IMBED) for in situ biomolecular detection based on environmentally resilient biosensor bacteria and miniaturized luminescence readout electronics that wirelessly communicate with an external device. As a proof of concept, we engineer heme-sensitive probiotic biosensors and demonstrate accurate diagnosis of gastrointestinal bleeding in swine. Additionally, we integrate alternative biosensors to demonstrate modularity and extensibility of the detection platform. IMBEDs enable new opportunities for gastrointestinal biomarker discovery and could transform the management and diagnosis of gastrointestinal disease. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  6. Comparative performance of novel self-sampling methods in detecting high-risk human papillomavirus in 30,130 women not attending cervical screening.

    PubMed

    Bosgraaf, Remko P; Verhoef, Viola M J; Massuger, Leon F A G; Siebers, Albert G; Bulten, Johan; de Kuyper-de Ridder, Gabriëlle M; Meijer, Chris J M; Snijders, Peter J F; Heideman, Daniëlle A M; IntHout, Joanna; van Kemenade, Folkert J; Melchers, Willem J G; Bekkers, Ruud L M

    2015-02-01

    We determined whether the participation rate for a brush-based cervicovaginal self-sampling device is noninferior to the participation rate for a lavage-based one for testing for hrHPV (high-risk human papillomavirus). Additionally, positivity rates for hrHPV, the detection rates for cervical intraepithelial neoplasia grades 2 and 3 or worse (CIN2+/3+), and user comfort were compared. A total of 35,477 non-responders of the regular cervical screening program aged 33-63 years were invited to participate. Eligible women (n = 30,130) were randomly assigned to receive either a brush-based or a lavage-based device, and a questionnaire for reporting user convenience. Self-sampling responders testing hrHPV-positive were invited for a physician-taken sample for cytology; triage-positive women were referred for colposcopy. A total of 5,218 women participated in the brush-based sampling group (34.6%) and 4809 women in the lavage-based group (31.9%), i.e. an absolute difference of 2.7% (95%CI 1.8-4.2). The hrHPV-positivity rates in the two groups were identical (8.3%, relative risk (RR) 0.99, 95%CI 0.87-1.13). The detection of CIN2+ and CIN3+ in the brush group (2.0% for CIN2+; 1.3% for CIN3+) was similar to that in the lavage group (1.9% for CIN2+; 1.0% for CIN3+) with a cumulative RR of 1.01, 95%CI 0.83-1.24 for CIN2+ and 1.25, 95%CI 0.92-1.70 for CIN3+. The two self-sampling devices performed similarly in user comfort. In conclusion, offering a brush-based device to non-responders is noninferior to offering a lavage-based device in terms of participation. The two self-sampling methods are equally effective in detecting hrHPV, CIN2+/CIN3+ and are both well accepted. © 2014 UICC.

  7. Application Of Light Valves For Continuous-Tone Printing

    NASA Astrophysics Data System (ADS)

    Vergona, Albert B.

    1989-07-01

    New opportunities are emerging in the graphic-arts pre-press market stimulated by the need for digitally created images. To meet this need, we have designed a cost-effective three-color digital printer using PLZT light valves. Transparent lead lanthanum zirconate titanate (PLZT) ceramic crystals when used as a linear modulator offer a number of significant benefits. The primary advantage is that the light valve is an efficient modulator of incoherent light providing a broad spectral output ranging from 400nm to well into the infrared region. In addition, light valves offer the advantages of being small, low cost, have a wide dynamic range (>1000 to 1), and can be used with simple optical designs. The characteristics of the PLZT material plays an important role in the performance of the light valve. A number of variables such as ceramic composition, electrode spacing, and ceramic thickness can be altered to affect its quadratic electrooptic behavior. Additionally, the modulator design requires a closed-loop servo to eliminate the errors caused by the device's remanent polarization and nonlinear behavior.

  8. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment

    PubMed Central

    Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source “OpenPhControl” software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device’s utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary. PMID:29509793

  9. Hacking medical devices a review - biomed 2013.

    PubMed

    Frenger, Paul

    2013-01-01

    Programmable, implantable and external biomedical devices (such as pacemakers, defibrillators, insulin pumps, pain management pumps, vagus nerve stimulators and others) may be vulnerable to unauthorized access, commonly referred to as “hacking”. This intrusion may lead to compromise of confidential patient data or loss of control of the device itself, which may be deadly. Risks to health from unauthorized access is in addition to hazards from faulty (“buggy”) software or circuitry. Historically, this aspect of medical device design has been underemphasized by both manufacturers and regulatory bodies until recently. However, an insulin pump was employed as a murder weapon in 2001 and successful hacking of an implantable defibrillator was demonstrated in 2008. To remedy these problems, professional groups have announced a variety of design standards and the governmental agencies of several countries have enacted device regulations. In turn, manufacturers have developed new software products and hardware circuits to assist biomedical engineering firms to improve their commercial offerings. In this paper the author discusses these issues, reviewing known problems and zero-day threats, with potential solutions. He outlines his approach to secure software and hardware challenges using the Forth language. A plausible scenario is described in which hacking of an implantable defibrillator by terrorists results in a severe national security threat to the United States.

  10. Data storage technology comparisons

    NASA Technical Reports Server (NTRS)

    Katti, Romney R.

    1990-01-01

    The role of data storage and data storage technology is an integral, though conceptually often underestimated, portion of data processing technology. Data storage is important in the mass storage mode in which generated data is buffered for later use. But data storage technology is also important in the data flow mode when data are manipulated and hence required to flow between databases, datasets and processors. This latter mode is commonly associated with memory hierarchies which support computation. VLSI devices can reasonably be defined as electronic circuit devices such as channel and control electronics as well as highly integrated, solid-state devices that are fabricated using thin film deposition technology. VLSI devices in both capacities play an important role in data storage technology. In addition to random access memories (RAM), read-only memories (ROM), and other silicon-based variations such as PROM's, EPROM's, and EEPROM's, integrated devices find their way into a variety of memory technologies which offer significant performance advantages. These memory technologies include magnetic tape, magnetic disk, magneto-optic disk, and vertical Bloch line memory. In this paper, some comparison between selected technologies will be made to demonstrate why more than one memory technology exists today, based for example on access time and storage density at the active bit and system levels.

  11. A Multimodal Deep Log-Based User Experience (UX) Platform for UX Evaluation

    PubMed Central

    Ali Khan, Wajahat; Hur, Taeho; Muhammad Bilal, Hafiz Syed; Ul Hassan, Anees; Lee, Sungyoung

    2018-01-01

    The user experience (UX) is an emerging field in user research and design, and the development of UX evaluation methods presents a challenge for both researchers and practitioners. Different UX evaluation methods have been developed to extract accurate UX data. Among UX evaluation methods, the mixed-method approach of triangulation has gained importance. It provides more accurate and precise information about the user while interacting with the product. However, this approach requires skilled UX researchers and developers to integrate multiple devices, synchronize them, analyze the data, and ultimately produce an informed decision. In this paper, a method and system for measuring the overall UX over time using a triangulation method are proposed. The proposed platform incorporates observational and physiological measurements in addition to traditional ones. The platform reduces the subjective bias and validates the user’s perceptions, which are measured by different sensors through objectification of the subjective nature of the user in the UX assessment. The platform additionally offers plug-and-play support for different devices and powerful analytics for obtaining insight on the UX in terms of multiple participants. PMID:29783712

  12. A Multimodal Deep Log-Based User Experience (UX) Platform for UX Evaluation.

    PubMed

    Hussain, Jamil; Khan, Wajahat Ali; Hur, Taeho; Bilal, Hafiz Syed Muhammad; Bang, Jaehun; Hassan, Anees Ul; Afzal, Muhammad; Lee, Sungyoung

    2018-05-18

    The user experience (UX) is an emerging field in user research and design, and the development of UX evaluation methods presents a challenge for both researchers and practitioners. Different UX evaluation methods have been developed to extract accurate UX data. Among UX evaluation methods, the mixed-method approach of triangulation has gained importance. It provides more accurate and precise information about the user while interacting with the product. However, this approach requires skilled UX researchers and developers to integrate multiple devices, synchronize them, analyze the data, and ultimately produce an informed decision. In this paper, a method and system for measuring the overall UX over time using a triangulation method are proposed. The proposed platform incorporates observational and physiological measurements in addition to traditional ones. The platform reduces the subjective bias and validates the user's perceptions, which are measured by different sensors through objectification of the subjective nature of the user in the UX assessment. The platform additionally offers plug-and-play support for different devices and powerful analytics for obtaining insight on the UX in terms of multiple participants.

  13. Customization, control, and characterization of a commercial haptic device for high-fidelity rendering of weak forces.

    PubMed

    Gurari, Netta; Baud-Bovy, Gabriel

    2014-09-30

    The emergence of commercial haptic devices offers new research opportunities to enhance our understanding of the human sensory-motor system. Yet, commercial device capabilities have limitations which need to be addressed. This paper describes the customization of a commercial force feedback device for displaying forces with a precision that exceeds the human force perception threshold. The device was outfitted with a multi-axis force sensor and closed-loop controlled to improve its transparency. Additionally, two force sensing resistors were attached to the device to measure grip force. Force errors were modeled in the frequency- and time-domain to identify contributions from the mass, viscous friction, and Coulomb friction during open- and closed-loop control. The effect of user interaction on system stability was assessed in the context of a user study which aimed to measure force perceptual thresholds. Findings based on 15 participants demonstrate that the system maintains stability when rendering forces ranging from 0-0.20 N, with an average maximum absolute force error of 0.041 ± 0.013 N. Modeling the force errors revealed that Coulomb friction and inertia were the main contributors to force distortions during respectively slow and fast motions. Existing commercial force feedback devices cannot render forces with the required precision for certain testing scenarios. Building on existing robotics work, this paper shows how a device can be customized to make it reliable for studying the perception of weak forces. The customized and closed-loop controlled device is suitable for measuring force perceptual thresholds. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Are Physicians Likely to Adopt Emerging Mobile Technologies? Attitudes and Innovation Factors Affecting Smartphone Use in the Southeastern United States

    PubMed Central

    Putzer, Gavin J; Park, Yangil

    2012-01-01

    The smartphone has emerged as an important technological device to assist physicians with medical decision making, clinical tasks, and other computing functions. A smartphone is a device that combines mobile telecommunication with Internet accessibility as well as word processing. Moreover, smartphones have additional features such as applications pertinent to clinical medicine and practice management. The purpose of this study was to investigate the innovation factors that affect a physician's decision to adopt an emerging mobile technological device such as a smartphone. The study sample consisted of 103 physicians from community hospitals and academic medical centers in the southeastern United States. Innovation factors are elements that affect an individual's attitude toward using and adopting an emerging technology. In our model, the innovation characteristics of compatibility, job relevance, the internal environment, observability, personal experience, and the external environment were all significant predictors of attitude toward using a smartphone. These influential innovation factors presumably are salient predictors of a physician's attitude toward using a smartphone to assist with clinical tasks. Health information technology devices such as smartphones offer promise as a means to improve clinical efficiency, medical quality, and care coordination and possibly reduce healthcare costs. PMID:22737094

  15. The technological obsolescence of the Brazilian eletronic ballot box.

    PubMed

    Camargo, Carlos Rogério; Faust, Richard; Merino, Eugênio; Stefani, Clarissa

    2012-01-01

    The electronic ballot box has played a significant role in the consolidation of Brazilian political process. It has enabled paper ballots extinction as a support for the elector's vote as well as for voting counting processes. It is also widely known that election automation has decisively collaborated to the legitimization of Brazilian democracy, getting rid of doubts about the winning candidates. In 1995, when the project was conceived, it represented a compromise solution, balancing technical efficiency and costs trade-offs. However, this architecture currently limits the ergonomic enhancements to the device operation, transportation, maintenance and storage. Nowadays are available in the market devices of reduced dimensions, based on novel computational architecture, namely tablet computers, which emphasizes usability, autonomy, portability, security and low power consumption. Therefore, the proposal under discussion is the replacement of the current electronic ballot boxes for tablet-based devices to improve the ergonomics aspects of the Brazilian voting process. These devices offer a plethora of integrated features (e.g., capacitive touchscreen, speakers, microphone) that enable highly usable and simple user interfaces, in addition to enhancing the voting process security mechanisms. Finally, their operational systems features allow for the development of highly secure applications, suitable to the requirements of a voting process.

  16. Routine counseling about intrauterine contraception for women seeking emergency contraception.

    PubMed

    Schwarz, E Bimla; Papic, Melissa; Parisi, Sara M; Baldauf, Erin; Rapkin, Rachel; Updike, Glenn

    2014-07-01

    To compare contraceptive knowledge and use among women seeking emergency contraception (EC) before and after an inner-city clinic began providing structured counseling and offering same-day intrauterine device (IUD) or implant placement to all women seeking EC. For 8 months before and 21 months after this change in clinic policy, women aged 15-45 who wanted to avoid pregnancy for at least 6 months were asked to complete surveys immediately, 3 and 12 months after their clinic visit. In addition, we abstracted electronic medical record (EMR) data on all women who sought EC (n=328) during this period. We used chi-squared tests to assess pre/post differences in survey and EMR data. Surveys were completed by 186 women. After the clinic began offering structured counseling, more women had accurate knowledge of the effectiveness of IUDs, immediately and 3 months after their clinic visit. In addition, more women initiated IUD or implant use (survey: 40% vs. 17% preintervention, p=0.04; EMR: 22% vs. 10% preintervention, p=0.01), and fewer had no contraceptive use (survey: 3% vs. 17% preintervention, p<0.01; EMR: 32% vs. 68%, p<0.01) in the 3 months after seeking EC. EMR data indicate that when same-day placement was offered, 11.0% of women received a same-day IUD. Of those who received a same-day IUD, 88% (23/26) reported IUD use at 3-months and 80% (12/15) at 12 months. Routine provision of structured counseling with the offer of same-day IUD placement increases knowledge and use of IUDs 3 months after women seek EC. Women seeking EC from family planning clinics should be offered counseling about highly effective reversible contraceptives with the option of same-day contraceptive placement. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Micro and nano-biomimetic structures for cell migration study fabricated by hybrid subtractive and additive 3D femtosecond laser processing

    NASA Astrophysics Data System (ADS)

    Sima, Felix; Serien, Daniela; Wu, Dong; Xu, Jian; Kawano, Hiroyuki; Midorikawa, Katsumi; Sugioka, Koji

    2017-02-01

    Lab-on-a-chip devices have been intensively developed during the last decade when emerging technologies offered possibilities to manufacture reliable devices with increased spatial resolution. These biochips allowed testing chemical reactions in nanoliter volumes with enhanced sensitivity and lower consumption of reagents. There is space to further consolidate biochip assembling processing since the new technologies attempt direct fabrication in view of reducing costs and time by increasing efficiency and functionalities. Rapid prototyping by ultrafast lasers which induces local modifications inside transparent materials of both glass and polymers with high precision at micro- and nanoscale is a promising tool for fabrication of such biochips. We have developed a new technology by combining subtractive ultrafast laser assisted chemical etching of glasses and additive two-photon polymerization to integrate 3D glass microfluidics and polymer microcomponents in a single biochip. The innovative hybrid "ship-in-a-bottle" approach is not only an instrument that can tailor 3D environments but also a tool to fabricate biomimetic in vivo structures inside a glass microfluidic chip. It was possible to create appropriate environment for cell culturing and to offer robustness and transparency for optical interrogation. Cancer cells were cultivated inside biochips and monitored over short and long periods. With the view of understanding cancer cells specific behavior such as migration or invasiveness inside human body, introduction of different geometrical configurations and chemical conditions were proposed. The cells were found responsive to a gradient of nutrient concentration through the microchannels of a 3D polymeric scaffold integrated inside glass biochip.

  18. Toward biomaterial-based implantable photonic devices

    NASA Astrophysics Data System (ADS)

    Humar, Matjaž; Kwok, Sheldon J. J.; Choi, Myunghwan; Yetisen, Ali K.; Cho, Sangyeon; Yun, Seok-Hyun

    2017-03-01

    Optical technologies are essential for the rapid and efficient delivery of health care to patients. Efforts have begun to implement these technologies in miniature devices that are implantable in patients for continuous or chronic uses. In this review, we discuss guidelines for biomaterials suitable for use in vivo. Basic optical functions such as focusing, reflection, and diffraction have been realized with biopolymers. Biocompatible optical fibers can deliver sensing or therapeutic-inducing light into tissues and enable optical communications with implanted photonic devices. Wirelessly powered, light-emitting diodes (LEDs) and miniature lasers made of biocompatible materials may offer new approaches in optical sensing and therapy. Advances in biotechnologies, such as optogenetics, enable more sophisticated photonic devices with a high level of integration with neurological or physiological circuits. With further innovations and translational development, implantable photonic devices offer a pathway to improve health monitoring, diagnostics, and light-activated therapies.

  19. Consumer sleep monitors: is there a baby in the bathwater?

    PubMed Central

    Russo, Kathryn; Goparaju, Balaji; Bianchi, Matt T

    2015-01-01

    The rapid expansion of consumer sleep devices is outpacing the validation data necessary to assess the potential use of these devices in clinical and research settings. Common sleep monitoring devices utilize a variety of sensors to track movement as well as cardiac and respiratory physiology. The variety of sensors and user-specific factors offer the potential, at least theoretically, for clinically relevant information. We describe the current challenges for interpretation of consumer sleep monitoring data, since the devices are mainly used in non-medical contexts (consumer use) although medically-definable sleep disorders may commonly occur in this setting. A framework for addressing questions of how certain devices might be useful is offered. We suggest that multistage validation efforts are crucially needed, from the level of sensor data and algorithm output, to extrapolations beyond healthy adults and into other populations and real-world environments. PMID:26604847

  20. Nanophotonic applications for silicon-on-insulator (SOI)

    NASA Astrophysics Data System (ADS)

    de la Houssaye, Paul R.; Russell, Stephen D.; Shimabukuro, Randy L.

    2004-07-01

    Silicon-on-insulator is a proven technology for very large scale integration of microelectronic devices. The technology also offers the potential for development of nanophotonic devices and the ability to interface such devices to the macroscopic world. This paper will report on fabrication techniques used to form nano-structured silicon wires on an insulating structure that is amenable to interfacing nanostructured sensors with high-performance microelectronic circuitry for practical implementation. Nanostructures formed on silicon-on-sapphire can also exploit the transparent substrate for novel device geometries. This research harnesses the unique properties of a high-quality single crystal film of silicon on sapphire and uses the film thickness as one of the confinement dimensions. Lateral arrays of silicon nanowires were fabricated in the thin (5 to 20 nm) silicon layer and studied. This technique offers simplified contact to individual wires and provides wire surfaces that are more readily accessible for controlled alteration and device designs.

  1. EUV mirror based absolute incident flux detector

    DOEpatents

    Berger, Kurt W.

    2004-03-23

    A device for the in-situ monitoring of EUV radiation flux includes an integrated reflective multilayer stack. This device operates on the principle that a finite amount of in-band EUV radiation is transmitted through the entire multilayer stack. This device offers improvements over existing vacuum photo-detector devices since its calibration does not change with surface contamination.

  2. Computational fluid dynamics (CFD) simulations of molten steel flow patterns and particle-wall adhesion in continuous casting of steels

    NASA Astrophysics Data System (ADS)

    Mohammadi-Ghaleni, Mahdi

    The Sun has long been the most important energy source for planet Earth. Sunlight offers the potential to function as a source of clean, renewable energy; photovoltaic (PV) cells have been designed to tap into this abundant solar energy to generate electricity. Organic photovoltaic (OPV) devices show promise as technologies capable of lightweight, low cost and flexible alternatives to traditional silicon PV but the nature of conjugated organic and polymeric semiconductors have limited performance and, therefore, application. However, recent advances have shown that the addition of pristine graphene (PG) to the active layer of OPV devices can yield three-fold performance improvements in blends of P3HT (poly(3-hexylthiophene-2,5-diyl) & PCBM (phenyl C 61 butyric acid methyl ester) and, later, in all-polymer blends of P3HT & F8BT (poly(9,9-dioctylfluorene-alt-benzothiadiazole). In both OPV systems, increased performance is believed to be due to high charge carrier mobility imparted by the PG additive to the composite active layer blend. In this work, the effect of addition of PG to the active layer blend of P3HT & PCPDTBT (poly[2,6-(4,4-bis-(2-ethylhexyl)-4H-cyclopenta [2,1-b;3,4-b']dithiophene)-alt-4,7(2,1,3-benzothiadiazole)]) systems was investigated. PV devices were designed, fabricated and tested using standard processing methods and testing procedures. Although PG increased OPV device performance relative to samples without PG, power conversion efficiency (eta) on an absolute scale was lower than expected despite the otherwise complementary properties of these materials. Based on the literature, the low performance of these devices was hypothesized to result from non-ideal active layer morphology, lacking charge carried percolation pathways to the electrodes. Small angle neutron scattering (SANS) was employed to probe the active layer morphology in polymer blend films similar to the active layers of the cells. Deuterated P3HT (d-P3HT) was used to exploit the large scattering length density (SLD) contrast between hydrogen and deuterium. Rigorous analysis of the SANS data allowed the nanostructure to be determined and a model of disk-like d-P3HT crystallites dispersed in a matrix of the amorphous polymers was constructed. This structure shows limited interfacial area for exciton dissociation and exhibits a lack of charge percolation pathways to the electrodes. Morphological insight offered by SANS analysis along with literature review allowed higher performance all-polymer photovoltaic cells to be designed and tested using the same semiconducting polymers. By introducing a co-solvent and modifying the thermal annealing procedure, significant performance gains were realized for subsequent devices. The increased performance observed following the change in procedure is believed to be due to enhanced active layer morphology and formation of a bulk heterojunction (BHJ) structure, to be studied in future work. Although there is room for further performance gains in P3HT-PCPDTBT devices as well as application to other OPV systems in future work, the methods, results and discussion presented here highlight the importance of structure-property relationships in all-polymer photovoltaic cells.

  3. Photoelectrochemical devices for solar water splitting - materials and challenges.

    PubMed

    Jiang, Chaoran; Moniz, Savio J A; Wang, Aiqin; Zhang, Tao; Tang, Junwang

    2017-07-31

    It is widely accepted within the community that to achieve a sustainable society with an energy mix primarily based on solar energy we need an efficient strategy to convert and store sunlight into chemical fuels. A photoelectrochemical (PEC) device would therefore play a key role in offering the possibility of carbon-neutral solar fuel production through artificial photosynthesis. The past five years have seen a surge in the development of promising semiconductor materials. In addition, low-cost earth-abundant co-catalysts are ubiquitous in their employment in water splitting cells due to the sluggish kinetics of the oxygen evolution reaction (OER). This review commences with a fundamental understanding of semiconductor properties and charge transfer processes in a PEC device. We then describe various configurations of PEC devices, including single light-absorber cells and multi light-absorber devices (PEC, PV-PEC and PV/electrolyser tandem cell). Recent progress on both photoelectrode materials (light absorbers) and electrocatalysts is summarized, and important factors which dominate photoelectrode performance, including light absorption, charge separation and transport, surface chemical reaction rate and the stability of the photoanode, are discussed. Controlling semiconductor properties is the primary concern in developing materials for solar water splitting. Accordingly, strategies to address the challenges for materials development in this area, such as the adoption of smart architectures, innovative device configuration design, co-catalyst loading, and surface protection layer deposition, are outlined throughout the text, to deliver a highly efficient and stable PEC device for water splitting.

  4. Efficient III-Nitride MIS-HEMT devices with high-κ gate dielectric for high-power switching boost converter circuits

    NASA Astrophysics Data System (ADS)

    Mohanbabu, A.; Mohankumar, N.; Godwin Raj, D.; Sarkar, Partha; Saha, Samar K.

    2017-03-01

    The paper reports the results of a systematic theoretical study on efficient recessed-gate, double-heterostructure, and normally-OFF metal-insulator-semiconductor high-electron mobility transistors (MIS-HEMTs), HfAlOx/AlGaN on Al2O3 substrate. In device architecture, a thin AlGaN layer is used in the AlGaN graded barrier MIS-HEMTs that offers an excellent enhancement-mode device operation with threshold voltage higher than 5.3 V and drain current above 0.64 A/mm along with high on-current/off-current ratio over 107 and subthreshold slope less than 73 mV/dec. In addition, a high OFF-state breakdown voltage of 1200 V is achieved for a device with a gate-to-drain distance and field-plate length of 15 μm and 5.3 μm, respectively at a drain current of 1 mA/mm with a zero gate bias, and the substrate grounded. The numerical device simulation results show that in comparison to a conventional AlGaN/GaN MIS-HEMT of similar design, a graded barrier MIS-HEMT device exhibits a better interface property, remarkable suppression of leakage current, and a significant improvement of breakdown voltage for HfAlOx gate dielectric. Finally, the benefit of HfAlOx graded-barrier AlGaN MIS-HEMTs based switching devices is evaluated on an ultra-low-loss converter circuit.

  5. Using Mobile Devices to Display, Overlay, and Animate Geophysical Data and Imagery

    NASA Astrophysics Data System (ADS)

    Batzli, S.; Parker, D.

    2011-12-01

    A major challenge in mobile-device map application development is to offer rich content and features with simple and intuitive controls and fast performance. Our goal is to bring visualization, animation, and notifications of near real-time weather and earth observation information derived from satellite and sensor data to mobile devices. Our robust back-end processing infrastructure can deliver content in the form of images, shapes, standard descriptive formats (eg. KML, JSON) or raw data to a variety of desktop software, browsers, and mobile devices on demand. We have developed custom interfaces for low-bandwidth browsers (including mobile phones) and high-feature browsers (including smartphones), as well as native applications for Android and iOS devices. Mobile devices offer time- and location-awareness and persistent data connections, allowing us to tailor timely notifications and displays to the user's geographic and time context. This presentation includes a live demo of how our mobile apps deliver animation of standard and custom data products in an interactive map interface.

  6. Unified Communications for Space Inventory Management

    NASA Technical Reports Server (NTRS)

    Gifford, Kevin K.; Fink, Patrick W.; Barton, Richard; Ngo, Phong H.

    2009-01-01

    To help assure mission success for long-duration exploration activities, NASA is actively pursuing wireless technologies that promote situational awareness and autonomy. Wireless technologies are typically extensible, offer freedom from wire tethers, readily support redundancy, offer potential for decreased wire weight, and can represent dissimilar implementation for increased reliability. In addition, wireless technologies can enable additional situational awareness that otherwise would be infeasible. For example, addition of wired sensors, the need for which might not have been apparent at the outset of a program, night be extremely costly due in part to the necessary routing of cables through the vehicle. RFID, or radio frequency identification, is a wireless technology with the potential for significant savings and increased reliability and safety in space operations. Perhaps the most obvious savings relate to the application of inventory management. A fully automated inventory management system is highly desirable for long-term sustaining operations in space environments. This assertion is evidenced by inventory activities on the International Space Station, which represents the most extensive inventory tracking experience base in the history of space operations. In the short tern, handheld RFID readers offer substantial savings owing to reduced crew time for inventory audits. Over the long term, a combination of improved RFID technology and operational concepts modified to fully utilize the technology should result in space based inventory management that is highly reliable and requires very little crew time. In addition to inventory management, RFID is likely to find space applications in real-time location and tracking systems. These could vary from coarse-resolution RFID portals to the high resolution afforded by ultra-wideband (UWB) RFID. Longer range RFID technologies that leverage passive surface acoustic wave (SAW) devices are being investigated to track assets on a lunar or planetary surface.

  7. Monolithic integration of SOI waveguide photodetectors and transimpedance amplifiers

    NASA Astrophysics Data System (ADS)

    Li, Shuxia; Tarr, N. Garry; Ye, Winnie N.

    2018-02-01

    In the absence of commercial foundry technologies offering silicon-on-insulator (SOI) photonics combined with Complementary Metal Oxide Semiconductor (CMOS) transistors, monolithic integration of conventional electronics with SOI photonics is difficult. Here we explore the implementation of lateral bipolar junction transistors (LBJTs) and Junction Field Effect Transistors (JFETs) in a commercial SOI photonics technology lacking MOS devices but offering a variety of n- and p-type ion implants intended to provide waveguide modulators and photodetectors. The fabrication makes use of the commercial Institute of Microelectronics (IME) SOI photonics technology. Based on knowledge of device doping and geometry, simple compact LBJT and JFET device models are developed. These models are then used to design basic transimpedance amplifiers integrated with optical waveguides. The devices' experimental current-voltage characteristics results are reported.

  8. Realization of Minimum and Maximum Gate Function in Ta2O5-based Memristive Devices

    NASA Astrophysics Data System (ADS)

    Breuer, Thomas; Nielen, Lutz; Roesgen, Bernd; Waser, Rainer; Rana, Vikas; Linn, Eike

    2016-04-01

    Redox-based resistive switching devices (ReRAM) are considered key enablers for future non-volatile memory and logic applications. Functionally enhanced ReRAM devices could enable new hardware concepts, e.g. logic-in-memory or neuromorphic applications. In this work, we demonstrate the implementation of ReRAM-based fuzzy logic gates using Ta2O5 devices to enable analogous Minimum and Maximum operations. The realized gates consist of two anti-serially connected ReRAM cells offering two inputs and one output. The cells offer an endurance up to 106 cycles. By means of exemplary input signals, each gate functionality is verified and signal constraints are highlighted. This realization could improve the efficiency of analogous processing tasks such as sorting networks in the future.

  9. A Study of Dip-Coatable, High-Capacitance Ion Gel Dielectrics for 3D EWOD Device Fabrication

    PubMed Central

    Clement, Carlos E.; Jiang, Dongyue; Thio, Si Kuan; Park, Sung-Yong

    2017-01-01

    We present a dip-coatable, high-capacitance ion gel dielectric for scalable fabrication of three-dimensional (3D) electrowetting-on-dielectric (EWOD) devices such as an n × n liquid prism array. Due to the formation of a nanometer-thick electric double layer (EDL) capacitor, an ion gel dielectric offers two to three orders higher specific capacitance (c ≈ 10 μF/cm2) than that of conventional dielectrics such as SiO2. However, the previous spin-coating method used for gel layer deposition poses several issues for 3D EWOD device fabrication, particularly when assembling multiple modules. Not only does the spin-coating process require multiple repetitions per module, but the ion gel layer also comes in risks of damage or contamination due to handling errors caused during assembly. In addition, it was observed that the chemical formulation previously used for the spin-coating method causes the surface defects on the dip-coated gel layers and thus leads to poor EWOD performance. In this paper, we alternatively propose a dip-coating method with modified gel solutions to obtain defect-free, functional ion gel layers without the issues arising from the spin-coating method for 3D device fabrication. A dip-coating approach offers a single-step coating solution with the benefits of simplicity, scalability, and high throughput for deposition of high-capacitance gel layers on non-planar EWOD devices. An ion gel solution was prepared by combining the [EMIM][TFSI] ionic liquid and the [P(VDF-HFP)] copolymer at various wt % ratios in acetone solvent. Experimental studies were conducted to fully understand the effects of chemical composition ratios in the gel solution and how varying thicknesses of ion gel and Teflon layers affects EWOD performance. The effectiveness and potentiality of dip-coatable gel layers for 3D EWOD devices have been demonstrated through fabricating 5 × 1 arrayed liquid prisms using a single-step dip-coating method. Each prism module has been individually controlled to achieve spatial beam steering without the need for bulky mechanical moving parts. PMID:28772400

  10. A Study of Dip-Coatable, High-Capacitance Ion Gel Dielectrics for 3D EWOD Device Fabrication.

    PubMed

    Clement, Carlos E; Jiang, Dongyue; Thio, Si Kuan; Park, Sung-Yong

    2017-01-05

    We present a dip-coatable, high-capacitance ion gel dielectric for scalable fabrication of three-dimensional (3D) electrowetting-on-dielectric (EWOD) devices such as an n × n liquid prism array. Due to the formation of a nanometer-thick electric double layer (EDL) capacitor, an ion gel dielectric offers two to three orders higher specific capacitance ( c ≈ 10 μF/cm²) than that of conventional dielectrics such as SiO₂. However, the previous spin-coating method used for gel layer deposition poses several issues for 3D EWOD device fabrication, particularly when assembling multiple modules. Not only does the spin-coating process require multiple repetitions per module, but the ion gel layer also comes in risks of damage or contamination due to handling errors caused during assembly. In addition, it was observed that the chemical formulation previously used for the spin-coating method causes the surface defects on the dip-coated gel layers and thus leads to poor EWOD performance. In this paper, we alternatively propose a dip-coating method with modified gel solutions to obtain defect-free, functional ion gel layers without the issues arising from the spin-coating method for 3D device fabrication. A dip-coating approach offers a single-step coating solution with the benefits of simplicity, scalability, and high throughput for deposition of high-capacitance gel layers on non-planar EWOD devices. An ion gel solution was prepared by combining the [EMIM][TFSI] ionic liquid and the [P(VDF-HFP)] copolymer at various wt % ratios in acetone solvent. Experimental studies were conducted to fully understand the effects of chemical composition ratios in the gel solution and how varying thicknesses of ion gel and Teflon layers affects EWOD performance. The effectiveness and potentiality of dip-coatable gel layers for 3D EWOD devices have been demonstrated through fabricating 5 × 1 arrayed liquid prisms using a single-step dip-coating method. Each prism module has been individually controlled to achieve spatial beam steering without the need for bulky mechanical moving parts.

  11. 3D Printing in Zero-G ISS Technology Demonstration

    NASA Technical Reports Server (NTRS)

    Johnston, Mallory M.; Werkheiser, Mary J.; Cooper, Kenneth G.; Snyder, Michael P.; Edmunson, Jennifer E.

    2014-01-01

    The National Aeronautics and Space Administration (NASA) has a long term strategy to fabricate components and equipment on-demand for manned missions to the Moon, Mars, and beyond. To support this strategy, NASA and Made in Space, Inc. are developing the 3D Printing In Zero-G payload as a Technology Demonstration for the International Space Station. The 3D Printing In Zero-G experiment will be the first machine to perform 3D printing in space. The greater the distance from Earth and the longer the mission duration, the more difficult resupply becomes; this requires a change from the current spares, maintenance, repair, and hardware design model that has been used on the International Space Station up until now. Given the extension of the ISS Program, which will inevitably result in replacement parts being required, the ISS is an ideal platform to begin changing the current model for resupply and repair to one that is more suitable for all exploration missions. 3D Printing, more formally known as Additive Manufacturing, is the method of building parts/ objects/tools layer-by-layer. The 3D Print experiment will use extrusion-based additive manufacturing, which involves building an object out of plastic deposited by a wire-feed via an extruder head. Parts can be printed from data files loaded on the device at launch, as well as additional files uplinked to the device while on-orbit. The plastic extrusion additive manufacturing process is a low-energy, low-mass solution to many common needs on board the ISS. The 3D Print payload will serve as the ideal first step to proving that process in space. It is unreasonable to expect NASA to launch large blocks of material from which parts or tools can be traditionally machined, and even more unreasonable to fly up specialized manufacturing hardware to perform the entire range of function traditionally machining requires. The technology to produce parts on demand, in space, offers unique design options that are not possible through traditional manufacturing methods while offering cost-effective, high-precision, low-unit on-demand manufacturing. Thus, Additive Manufacturing capabilities are the foundation of an advanced manufacturing in space roadmap.

  12. 3D Printing Polymers with Supramolecular Functionality for Biological Applications.

    PubMed

    Pekkanen, Allison M; Mondschein, Ryan J; Williams, Christopher B; Long, Timothy E

    2017-09-11

    Supramolecular chemistry continues to experience widespread growth, as fine-tuned chemical structures lead to well-defined bulk materials. Previous literature described the roles of hydrogen bonding, ionic aggregation, guest/host interactions, and π-π stacking to tune mechanical, viscoelastic, and processing performance. The versatility of reversible interactions enables the more facile manufacturing of molded parts with tailored hierarchical structures such as tissue engineered scaffolds for biological applications. Recently, supramolecular polymers and additive manufacturing processes merged to provide parts with control of the molecular, macromolecular, and feature length scales. Additive manufacturing, or 3D printing, generates customizable constructs desirable for many applications, and the introduction of supramolecular interactions will potentially increase production speed, offer a tunable surface structure for controlling cell/scaffold interactions, and impart desired mechanical properties through reinforcing interlayer adhesion and introducing gradients or self-assembled structures. This review details the synthesis and characterization of supramolecular polymers suitable for additive manufacture and biomedical applications as well as the use of supramolecular polymers in additive manufacturing for drug delivery and complex tissue scaffold formation. The effect of supramolecular assembly and its dynamic behavior offers potential for controlling the anisotropy of the printed objects with exquisite geometrical control. The potential for supramolecular polymers to generate well-defined parts, hierarchical structures, and scaffolds with gradient properties/tuned surfaces provides an avenue for developing next-generation biomedical devices and tissue scaffolds.

  13. Radioguided surgery and the GOSTT concept: From pre-operative image and intraoperative navigation to image-assisted excision.

    PubMed

    Bowles, H; Sánchez, N; Tapias, A; Paredes, P; Campos, F; Bluemel, C; Valdés Olmos, R A; Vidal-Sicart, S

    Radio-guided surgery has been developed for application in those disease scheduled for surgical management, particularly in areas of complex anatomy. This is based on the use of pre-operative scintigraphic planar, tomographic and fused SPECT/CT images, and the possibility of 3D reconstruction for the subsequent intraoperative locating of active lesions using handheld devices (detection probes, gamma cameras, etc.). New tracers and technologies have also been incorporated into these surgical procedures. The combination of visual and acoustic signals during the intraoperative procedure has become possible with new portable imaging modalities. In daily practice, the images offered by these techniques and devices combine perioperative nuclear medicine imaging with the superior resolution of additional optical guidance in the operating room. In many ways they provide real-time images, allowing accurate guidance during surgery, a reduction in the time required for tissue location and an anatomical environment for surgical recognition. All these approaches have been included in the concept known as (radio) Guided intraOperative Scintigraphic Tumour Targeting (GOSTT). This article offers a general view of different nuclear medicine and allied technologies used for several GOSTT procedures, and illustrates the crossing of technological frontiers in radio-guided surgery. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  14. Biomechanical analysis of a new lumbar interspinous device with optimized topology.

    PubMed

    Chen, Chen-Sheng; Shih, Shih-Liang

    2018-01-06

    Interspinous spacers used stand-alone preserve joint movement but provide little protection for diseased segments of the spine. Used as adjuncts with fusion, interspinous spacers offer rigid stability but may accelerate degeneration on adjacent levels. Our new device is intended to balance the stability and preserves motion provided by the implant. A new interspinous spacer was devised according to the results of topology optimization studies. Four finite element (FE) spine models were created that consisted of an intact spine without an implant, implantation of the novel, the device for intervertebral assisted motion (DIAM system), and the Dynesys system. All models were loaded with moments, and their range of motions (ROMs), peak disc stresses, and facet contact forces were analyzed. The limited motion segment ROMs, shielded disc stresses, and unloaded facet contact forces of the new devices were greater than those of the DIAM and Dynesys system at L3-L4 in almost all directions of movements. The ROMs, disc stresses, and facet contact forces of the new devices at L2-L3 were slightly greater than those in the DIAM system, but much lower than those in the Dynesys system in most directions. This study demonstrated that the new device provided more stability at the instrumented level than the DIAM system did, especially in lateral rotation and the bending direction. The device caused fewer adjacent ROMs, lower disc stresses, and lower facet contact forces than the Dynesys system did. Additionally, this study conducted topology optimization to design the new device and created a smaller implant for minimal invasive surgery.

  15. Devices and tasks involved in the objective assessment of standing dynamic balancing - A systematic literature review.

    PubMed

    Petró, Bálint; Papachatzopoulou, Alexandra; Kiss, Rita M

    2017-01-01

    Static balancing assessment is often complemented with dynamic balancing tasks. Numerous dynamic balancing assessment methods have been developed in recent decades with their corresponding balancing devices and tasks. The aim of this systematic literature review is to identify and categorize existing objective methods of standing dynamic balancing ability assessment with an emphasis on the balancing devices and tasks being used. Three major scientific literature databases (Science Direct, Web of Science, PLoS ONE) and additional sources were used. Studies had to use a dynamic balancing device and a task described in detail. Evaluation had to be based on objectively measureable parameters. Functional tests without instrumentation evaluated exclusively by a clinician were excluded. A total of 63 articles were included. The data extracted during full-text assessment were: author and date; the balancing device with the balancing task and the measured parameters; the health conditions, size, age and sex of participant groups; and follow-up measurements. A variety of dynamic balancing assessment devices were identified and categorized as 1) Solid ground, 2) Balance board, 3) Rotating platform, 4) Horizontal translational platform, 5) Treadmill, 6) Computerized Dynamic Posturography, and 7) Other devices. The group discrimination ability of the methods was explored and the conclusions of the studies were briefly summarized. Due to the wide scope of this search, it provides an overview of balancing devices and do not represent the state-of-the-art of any single method. The identified dynamic balancing assessment methods are offered as a catalogue of candidate methods to complement static assessments used in studies involving postural control.

  16. Bis(tri-n-hexylsilyl oxide) silicon phthalocyanine: a unique additive in ternary bulk heterojunction organic photovoltaic devices.

    PubMed

    Lessard, Benoît H; Dang, Jeremy D; Grant, Trevor M; Gao, Dong; Seferos, Dwight S; Bender, Timothy P

    2014-09-10

    Previous studies have shown that the use of bis(tri-n-hexylsilyl oxide) silicon phthalocyanine ((3HS)2-SiPc) as an additive in a P3HT:PC61BM cascade ternary bulk heterojunction organic photovoltaic (BHJ OPV) device results in an increase in the short circuit current (J(SC)) and efficiency (η(eff)) of up to 25% and 20%, respectively. The previous studies have attributed the increase in performance to the presence of (3HS)2-SiPc at the BHJ interface. In this study, we explored the molecular characteristics of (3HS)2-SiPc which makes it so effective in increasing the OPV device J(SC) and η(eff. Initially, we synthesized phthalocyanine-based additives using different core elements such as germanium and boron instead of silicon, each having similar frontier orbital energies compared to (3HS)2-SiPc and tested their effect on BHJ OPV device performance. We observed that addition of bis(tri-n-hexylsilyl oxide) germanium phthalocyanine ((3HS)2-GePc) or tri-n-hexylsilyl oxide boron subphthalocyanine (3HS-BsubPc) resulted in a nonstatistically significant increase in JSC and η(eff). Secondly, we kept the silicon phthalocyanine core and substituted the tri-n-hexylsilyl solubilizing groups with pentadecyl phenoxy groups and tested the resulting dye in a BHJ OPV. While an increase in JSC and η(eff) was observed at low (PDP)2-SiPc loadings, the increase was not as significant as (3HS)2-SiPc; therefore, (3HS)2-SiPc is a unique additive. During our study, we observed that (3HS)2-SiPc had an extraordinary tendency to crystallize compared to the other compounds in this study and our general experience. On the basis of this observation, we have offered a hypothesis that when (3HS)2-SiPc migrates to the P3HT:PC61BM interface the reason for its unique performance is not solely due to its frontier orbital energies but also might be due to a high driving force for crystallization.

  17. Diffusion-Driven Charge Transport in Light Emitting Devices

    PubMed Central

    Oksanen, Jani; Suihkonen, Sami

    2017-01-01

    Almost all modern inorganic light-emitting diode (LED) designs are based on double heterojunctions (DHJs) whose structure and current injection principle have remained essentially unchanged for decades. Although highly efficient devices based on the DHJ design have been developed and commercialized for energy-efficient general lighting, the conventional DHJ design requires burying the active region (AR) inside a pn-junction. This has hindered the development of emitters utilizing nanostructured ARs located close to device surfaces such as nanowires or surface quantum wells. Modern DHJ III-N LEDs also exhibit resistive losses that arise from the DHJ device geometry. The recently introduced diffusion-driven charge transport (DDCT) emitter design offers a novel way to transport charge carriers to unconventionally placed ARs. In a DDCT device, the AR is located apart from the pn-junction and the charge carriers are injected into the AR by bipolar diffusion. This device design allows the integration of surface ARs to semiconductor LEDs and offers a promising method to reduce resistive losses in high power devices. In this work, we present a review of the recent progress in gallium nitride (GaN) based DDCT devices, and an outlook of potential DDCT has for opto- and microelectronics. PMID:29231900

  18. Investigation of graphene-based nanoscale radiation sensitive materials

    NASA Astrophysics Data System (ADS)

    Robinson, Joshua A.; Wetherington, Maxwell; Hughes, Zachary; LaBella, Michael, III; Bresnehan, Michael

    2012-06-01

    Current state-of-the-art nanotechnology offers multiple benefits for radiation sensing applications. These include the ability to incorporate nano-sized radiation indicators into widely used materials such as paint, corrosion-resistant coatings, and ceramics to create nano-composite materials that can be widely used in everyday life. Additionally, nanotechnology may lead to the development of ultra-low power, flexible detection systems that can be embedded in clothing or other systems. Graphene, a single layer of graphite, exhibits exceptional electronic and structural properties, and is being investigated for high-frequency devices and sensors. Previous work indicates that graphene-oxide (GO) - a derivative of graphene - exhibits luminescent properties that can be tailored based on chemistry; however, exploration of graphene-oxide's ability to provide a sufficient change in luminescent properties when exposed to gamma or neutron radiation has not been carried out. We investigate the mechanisms of radiation-induced chemical modifications and radiation damage induced shifts in luminescence in graphene-oxide materials to provide a fundamental foundation for further development of radiation sensitive detection architectures. Additionally, we investigate the integration of hexagonal boron nitride (hBN) with graphene-based devices to evaluate radiation induced conductivity in nanoscale devices. Importantly, we demonstrate the sensitivity of graphene transport properties to the presence of alpha particles, and discuss the successful integration of hBN with large area graphene electrodes as a means to provide the foundation for large-area nanoscale radiation sensors.

  19. The Active Target Time Projection Chamber at NSCL

    NASA Astrophysics Data System (ADS)

    Bazin, D.; Bradt, J.; Ayyad, Y.; Mittig, W.; Ahn, T.; Beceiro-Novo, S.; Carpenter, L.; Cortesi, M.; Fritsch, A.; Kolata, J. J.; Lynch, W.; Watwood, N.

    2017-11-01

    Reactions in inverse kinematics close to the Coulomb barrier offer unique opportunities to study exotic nuclei, but they are plagued by the difficulty to efficiently and precisely measure the characteristics of the emerging particles. The Active Target Time Projection Chamber (AT-TPC) offers an elegant solution to this dilemma. In this device, the detector gas of the time projection chamber is at the same time the target in which nuclear reactions take place. The use of this new paradigm offers several advantages over conventional inert target methods, the most significant being the ability to increase the luminosity of experiments without loss of resolution. The AT-TPC and some results obtained on resonant α scattering to explore the clustering properties of neutron-rich nuclei are presented, as well as fusion cross section results using a 10Be radioactive beam. In addition, the first re-accelerated radioactive beam experiment using the fully commissioned ReA3 linac was conducted recently at the NSCL with the AT-TPC, where proton resonant scattering of a 4.6 MeV/u 46Ar beam was used to measure the neutron single-particle strength in 47Ar.

  20. Thermionic/AMTEC cascade converter concept for high-efficiency space power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagan, T.H. van; Smith, J.N. Jr.; Schuller, M.

    1996-12-31

    This paper presents trade studies that address the use of the thermionic/AMTEC cell--a cascaded, high-efficiency, static power conversion concept that appears well-suited to space power applications. Both the thermionic and AMTEC power conversion approaches have been shown to be promising candidates for space power. Thermionics offers system compactness via modest efficiency at high heat rejection temperatures, and AMTEC offers high efficiency at modest heat rejection temperature. From a thermal viewpoint the two are ideally suited for cascaded power conversion: thermionic heat rejection and AMTEC heat source temperatures are essentially the same. In addition to realizing conversion efficiencies potentially as highmore » as 35--40%, such a cascade offers the following perceived benefits: survivability; simplicity; technology readiness; and technology growth. Mechanical approaches and thermal/electric matching criteria for integrating thermionics and AMTEC into a single conversion device are described. Focusing primarily on solar thermal space power applications, parametric trends are presented to show the performance and cost potential that should be achievable with present-day technology in cascaded thermionic/AMTEC systems.« less

  1. Environmental Controls.

    ERIC Educational Resources Information Center

    Schneiderman, Helen, Ed.

    1994-01-01

    Environmental control units, or ECUs, are devices or systems which allow for alternate access to electronic or electrical devices and those objects, like draperies and doors, which may be adapted for use with electricity. Such devices offer the person with a mobility limitation the opportunity to control his or her environment, thus enhancing the…

  2. Hollow fiber gas-liquid membrane contactors for acid gas capture: a review.

    PubMed

    Mansourizadeh, A; Ismail, A F

    2009-11-15

    Membrane contactors using microporous membranes for acid gas removal have been extensively reviewed and discussed. The microporous membrane acts as a fixed interface between the gas and the liquid phase without dispersing one phase into another that offers a flexible modular and energy efficient device. The gas absorption process can offer a high selectivity and a high driving force for transport even at low concentrations. Using hollow fiber gas-liquid membrane contactors is a promising alternative to conventional gas absorption systems for acid gas capture from gas streams. Important aspects of membrane contactor as an efficient energy devise for acid gas removal including liquid absorbents, membrane characteristics, combination of membrane and absorbent, mass transfer, membrane modules, model development, advantages and disadvantages were critically discussed. In addition, current status and future potential in research and development of gas-liquid membrane contactors for acid gas removal were also briefly discussed.

  3. Implementation of laser speckle contrast analysis as connection kit for mobile phone for assessment of skin blood flow

    NASA Astrophysics Data System (ADS)

    Jakovels, Dainis; Saknite, Inga; Spigulis, Janis

    2014-05-01

    Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.

  4. Volatile Organic Compound Optical Fiber Sensors: A Review

    PubMed Central

    Elosua, Cesar; Matias, Ignacio R.; Bariain, Candido; Arregui, Francisco J.

    2006-01-01

    Volatile organic compound (VOC) detection is a topic of growing interest with applications in diverse fields, ranging from environmental uses to the food or chemical industries. Optical fiber VOC sensors offering new and interesting properties which overcame some of the inconveniences found on traditional gas sensors appeared over two decades ago. Thanks to its minimum invasive nature and the advantages that optical fiber offers such as light weight, passive nature, low attenuation and the possibility of multiplexing, among others, these sensors are a real alternative to electronic ones in electrically noisy environments where electronic sensors cannot operate correctly. In the present work, a classification of these devices has been made according to the sensing mechanism and taking also into account the sensing materials or the different methods of fabrication. In addition, some solutions already implemented for the detection of VOCs using optical fiber sensors will be described with detail.

  5. Detection of orbital angular momentum using a photonic integrated circuit.

    PubMed

    Rui, Guanghao; Gu, Bing; Cui, Yiping; Zhan, Qiwen

    2016-06-20

    Orbital angular momentum (OAM) state of photons offer an attractive additional degree of freedom that has found a variety of applications. Measurement of OAM state, which is a critical task of these applications, demands photonic integrated devices for improved fidelity, miniaturization, and reconfiguration. Here we report the design of a silicon-integrated OAM receiver that is capable of detecting distinct and variable OAM states. Furthermore, the reconfiguration capability of the detector is achieved by applying voltage to the GeSe film to form gratings with alternate states. The resonant wavelength for arbitrary OAM state is demonstrated to be tunable in a quasi-linear manner through adjusting the duty cycle of the gratings. This work provides a viable approach for the realization of a compact integrated OAM detection device with enhanced functionality that may find important applications in optical communications and information processing with OAM states.

  6. Hybrid permeable metal-base transistor with large common-emitter current gain and low operational voltage.

    PubMed

    Feng, Chengang; Yi, Mingdong; Yu, Shunyang; Hümmelgen, Ivo A; Zhang, Tong; Ma, Dongge

    2008-04-01

    We demonstrate the suitability of N,N'-diphenyl-N,N'-bis(1-naphthylphenyl)-1,1'-biphenyl-4,4'-diamine (NPB), an organic semiconductor widely used in organic light-emitting diodes (OLEDs), for high-gain, low operational voltage nanostructured vertical-architecture transistors, which operate as permeable-base transistors. By introducing vanadium oxide (V2O5) between the injecting metal and NPB layer at the transistor emitter, we reduced the emitter operational voltage. The addition of two Ca layers, leading to a Ca/Ag/Ca base, allowed to obtain a large value of common-emitter current gain, but still retaining the permeable-base transistor character. This kind of vertical devices produced by simple technologies offer attractive new possibilities due to the large variety of available molecular semiconductors, opening the possibility of incorporating new functionalities in silicon-based devices.

  7. Chemiresistor Devices for Chemical Warfare Agent Detection Based on Polymer Wrapped Single-Walled Carbon Nanotubes

    PubMed Central

    Fennell, John F.; Hamaguchi, Hitoshi; Yoon, Bora; Swager, Timothy M.

    2017-01-01

    Chemical warfare agents (CWA) continue to present a threat to civilian populations and military personnel in operational areas all over the world. Reliable measurements of CWAs are critical to contamination detection, avoidance, and remediation. The current deployed systems in United States and foreign militaries, as well as those in the private sector offer accurate detection of CWAs, but are still limited by size, portability and fabrication cost. Herein, we report a chemiresistive CWA sensor using single-walled carbon nanotubes (SWCNTs) wrapped with poly(3,4-ethylenedioxythiophene) (PEDOT) derivatives. We demonstrate that a pendant hexafluoroisopropanol group on the polymer that enhances sensitivity to a nerve agent mimic, dimethyl methylphosphonate, in both nitrogen and air environments to concentrations as low as 5 ppm and 11 ppm, respectively. Additionally, these PEDOT/SWCNT derivative sensor systems experience negligible device performance over the course of two weeks under ambient conditions. PMID:28452929

  8. Exploiting bistable oscillator subharmonics for magnified broadband vibration energy harvesting

    NASA Astrophysics Data System (ADS)

    Huguet, Thomas; Badel, Adrien; Lallart, Mickaël

    2017-10-01

    Recent research on primary battery alternatives for supplying autonomous wireless devices has recently highlighted the advantages of nonlinear oscillators' dynamics and more particularly bistable oscillators' behavior for ambient vibration harvesting. The key property of bistable oscillators compared to linear ones is their enhanced operational frequency bandwidth under harmonic excitation, potentially leading to a better adaptation to the environment. However, the classical frequency response characterization of such devices does not reveal all the possible dynamic behaviors offered by bistable oscillators. Thus, subharmonic motions are experimentally investigated in this letter, and their energy harvesting potential as well as their ability to enhance the bistable generator bandwidth is evaluated. The results obtained with a generator integrating buckled beams for the bistability feature show that, in addition to the commonly considered harmonic behavior, subharmonics allow widening of the useful operating frequency band of the bistable microgenerator by 180% compared to the sole exploitation of the first harmonic motion.

  9. Chemiresistor Devices for Chemical Warfare Agent Detection Based on Polymer Wrapped Single-Walled Carbon Nanotubes.

    PubMed

    Fennell, John F; Hamaguchi, Hitoshi; Yoon, Bora; Swager, Timothy M

    2017-04-28

    Chemical warfare agents (CWA) continue to present a threat to civilian populations and military personnel in operational areas all over the world. Reliable measurements of CWAs are critical to contamination detection, avoidance, and remediation. The current deployed systems in United States and foreign militaries, as well as those in the private sector offer accurate detection of CWAs, but are still limited by size, portability and fabrication cost. Herein, we report a chemiresistive CWA sensor using single-walled carbon nanotubes (SWCNTs) wrapped with poly(3,4-ethylenedioxythiophene) (PEDOT) derivatives. We demonstrate that a pendant hexafluoroisopropanol group on the polymer that enhances sensitivity to a nerve agent mimic, dimethyl methylphosphonate, in both nitrogen and air environments to concentrations as low as 5 ppm and 11 ppm, respectively. Additionally, these PEDOT/SWCNT derivative sensor systems experience negligible device performance over the course of two weeks under ambient conditions.

  10. Computer modelling of aluminum-gallium arsenide/gallium arsenide multilayer photovoltaics. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Wagner, Michael Broderick

    1987-01-01

    The modeled cascade cells offer an alternative to conventional series cascade designs that require a monolithic intercell ohmic contact. Selective electrodes provide a simple means of fabricating three-terminal devices, which can be configured in complementary pairs to circumvent the attendant losses and fabrication complexities of intercell ohmic contacts. Moreover, selective electrodes allow incorporation of additional layers in the upper subcell which can improve spectral response and increase radiation tolerance. Realistic simulations of such cells operating under one-sun AMO conditions show that the seven-layer structure is optimum from the standpoint of beginning-of-life efficiency and radiation tolerance. Projected efficiencies exceed 26 percent. Under higher concentration factors, it should be possible to achieve efficiencies beyond 30 percent. However, to simulate operation at high concentration will require a model for resistive losses. Overall, these devices appear to be a promising contender for future space applications.

  11. Controlling levonorgestrel binding and release in a multi-purpose prevention technology vaginal ring device.

    PubMed

    Murphy, Diarmaid J; Boyd, Peter; McCoy, Clare F; Kumar, Sandeep; Holt, Jonathon D S; Blanda, Wendy; Brimer, Andrew N; Malcolm, R Karl

    2016-03-28

    Despite a long history of incorporating steroids into silicone elastomers for drug delivery applications, little is presently known about the propensity for irreversible drug binding in these systems. In this study, the ability of the contraceptive progestin levonorgestrel to bind chemically with hydrosilane groups in addition-cure silicone elastomers has been thoroughly investigated. Cure time, cure temperature, levonorgestrel particle size, initial levonorgestrel loading and silicone elastomer type were demonstrated to be key parameters impacting the extent of levonorgestrel binding, each through their influence on the solubility of levonorgestrel in the silicone elastomer. Understanding and overcoming this levonorgestrel binding phenomenon is critical for the ongoing development of a number of drug delivery products, including a multi-purpose technology vaginal ring device offering simultaneous release of levonorgestrel and dapivirine - a lead candidate antiretroviral microbicide - for combination HIV prevention and hormonal contraception. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Ultra-thin, conformal, and hydratable color-absorbers using silk protein hydrogel

    NASA Astrophysics Data System (ADS)

    Umar, Muhammad; Min, Kyungtaek; Jo, Minsik; Kim, Sunghwan

    2018-06-01

    Planar and multilayered photonic devices offer unprecedented opportunities in biological and chemical sensing due to strong light-matter interactions. However, uses of rigid substances such as semiconductors and dielectrics confront photonic devices with issues of biocompatibility and a mechanical mismatch for their application on humid, uneven, and soft biological surfaces. Here, we report that favorable material traits of natural silk protein led to the fabrication of an ultra-thin, conformal, and water-permeable (hydratable) metal-insulator-metal (MIM) color absorber that was mapped on soft, curved, and hydrated biological interfaces. Strong absorption was induced in the MIM structure and could be tuned by hydration and tilting of the sample. The transferred MIM color absorbers reached the exhibition of a very strong resonant absorption in the visible and near infra-red ranges. In addition, we demonstrated that the conformal resonator could function as a refractometric glucose sensor applied on a contact lens.

  13. Scalable maskless patterning of nanostructures using high-speed scanning probe arrays

    NASA Astrophysics Data System (ADS)

    Chen, Chen; Akella, Meghana; Du, Zhidong; Pan, Liang

    2017-08-01

    Nanoscale patterning is the key process to manufacture important products such as semiconductor microprocessors and data storage devices. Many studies have shown that it has the potential to revolutionize the functions of a broad range of products for a wide variety of applications in energy, healthcare, civil, defense and security. However, tools for mass production of these devices usually cost tens of million dollars each and are only affordable to the established semiconductor industry. A new method, nominally known as "pattern-on-the- y", that involves scanning an array of optical or electrical probes at high speed to form nanostructures and offers a new low-cost approach for nanoscale additive patterning. In this paper, we report some progress on using this method to pattern self-assembled monolayers (SAMs) on silicon substrate. We also functionalize the substrate with gold nanoparticle based on the SAM to show the feasibility of preparing amphiphilic and multi-functional surfaces.

  14. Enhanced light output from a nitride-based power chip of green light-emitting diodes with nano-rough surface using nanoimprint lithography.

    PubMed

    Huang, H W; Lin, C H; Yu, C C; Lee, B D; Chiu, C H; Lai, C F; Kuo, H C; Leung, K M; Lu, T C; Wang, S C

    2008-05-07

    Enhanced light extraction from a GaN-based power chip (PC) of green light-emitting diodes (LEDs) with a rough p-GaN surface using nanoimprint lithography is presented. At a driving current of 350 mA and with a chip size of 1 mm × 1 mm packaged on transistor outline (TO)-cans, the light output power of the green PC LEDs with nano-rough p-GaN surface is enhanced by 48% when compared with the same device without a rough p-GaN surface. In addition, by examining the radiation patterns, the green PC LED with nano-rough p-GaN surface shows stronger light extraction with a wider view angle. These results offer promising potential to enhance the light output powers of commercial light-emitting devices by using the technique of nanoimprint lithography under suitable nanopattern design.

  15. [Medical image compression: a review].

    PubMed

    Noreña, Tatiana; Romero, Eduardo

    2013-01-01

    Modern medicine is an increasingly complex activity , based on the evidence ; it consists of information from multiple sources : medical record text , sound recordings , images and videos generated by a large number of devices . Medical imaging is one of the most important sources of information since they offer comprehensive support of medical procedures for diagnosis and follow-up . However , the amount of information generated by image capturing gadgets quickly exceeds storage availability in radiology services , generating additional costs in devices with greater storage capacity . Besides , the current trend of developing applications in cloud computing has limitations, even though virtual storage is available from anywhere, connections are made through internet . In these scenarios the optimal use of information necessarily requires powerful compression algorithms adapted to medical activity needs . In this paper we present a review of compression techniques used for image storage , and a critical analysis of them from the point of view of their use in clinical settings.

  16. Pulse Detonation Engines for High Speed Flight

    NASA Technical Reports Server (NTRS)

    Povinelli, Louis A.

    2002-01-01

    Revolutionary concepts in propulsion are required in order to achieve high-speed cruise capability in the atmosphere and for low cost reliable systems for earth to orbit missions. One of the advanced concepts under study is the air-breathing pulse detonation engine. Additional work remains in order to establish the role and performance of a PDE in flight applications, either as a stand-alone device or as part of a combined cycle system. In this paper, we shall offer a few remarks on some of these remaining issues, i.e., combined cycle systems, nozzles and exhaust systems and thrust per unit frontal area limitations. Currently, an intensive experimental and numerical effort is underway in order to quantify the propulsion performance characteristics of this device. In this paper, we shall highlight our recent efforts to elucidate the propulsion potential of pulse detonation engines and their possible application to high-speed or hypersonic systems.

  17. Evaluation of polymer based third order nonlinear integrated optics devices

    NASA Astrophysics Data System (ADS)

    Driessen, A.; Hoekstra, H. J. W. M.; Blom, F. C.; Horst, F.; Krijnen, G. J. M.; van Schoot, J. B. P.; Lambeck, P. V.; Popma, Th. J. A.; Diemeer, M. B.

    1998-01-01

    Nonlinear polymers are promising materials for high speed active integrated optics devices. In this paper we evaluate the perspectives polymer based nonlinear optical devices can offer. Special attention is directed to the materials aspects. In our experimental work we applied mainly Akzo Nobel DANS side-chain polymer that exhibits large second and third order coefficients. This material has been characterized by third harmonic generation, z-scan and pump-probe measurements. In addition, various waveguiding structures have been used to measure the nonlinear absorption (two photon absorption) on a ps time-scale. Finally an integrated optics Mach Zehnder interferometer has been realized and evaluated. It is shown that the DANS side-chain polymer has many of the desired properties: the material is easily processable in high-quality optical waveguiding structures, has low linear absorption and its nonlinearity has a pure electronic origin. More materials research has to be done to arrive at materials with higher nonlinear coefficients to allow switching at moderate light intensity ( < 1 W peak power) and also with lower nonlinear absorption coefficients.

  18. A programmable nanoreplica molding for the fabrication of nanophotonic devices.

    PubMed

    Liu, Longju; Zhang, Jingxiang; Badshah, Mohsin Ali; Dong, Liang; Li, Jingjing; Kim, Seok-min; Lu, Meng

    2016-03-01

    The ability to fabricate periodic structures with sub-wavelength features has a great potential for impact on integrated optics, optical sensors, and photovoltaic devices. Here, we report a programmable nanoreplica molding process to fabricate a variety of sub-micrometer periodic patterns using a single mold. The process utilizes a stretchable mold to produce the desired periodic structure in a photopolymer on glass or plastic substrates. During the replica molding process, a uniaxial force is applied to the mold and results in changes of the periodic structure, which resides on the surface of the mold. Direction and magnitude of the force determine the array geometry, including the lattice constant and arrangement. By stretching the mold, 2D arrays with square, rectangular, and triangular lattice structures can be fabricated. As one example, we present a plasmonic crystal device with surface plasmon resonances determined by the force applied during molding. In addition, photonic crystal slabs with different array patterns are fabricated and characterized. This unique process offers the capability of generating various periodic nanostructures rapidly and inexpensively.

  19. Spike processing with a graphene excitable laser

    PubMed Central

    Shastri, Bhavin J.; Nahmias, Mitchell A.; Tait, Alexander N.; Rodriguez, Alejandro W.; Wu, Ben; Prucnal, Paul R.

    2016-01-01

    Novel materials and devices in photonics have the potential to revolutionize optical information processing, beyond conventional binary-logic approaches. Laser systems offer a rich repertoire of useful dynamical behaviors, including the excitable dynamics also found in the time-resolved “spiking” of neurons. Spiking reconciles the expressiveness and efficiency of analog processing with the robustness and scalability of digital processing. We demonstrate a unified platform for spike processing with a graphene-coupled laser system. We show that this platform can simultaneously exhibit logic-level restoration, cascadability and input-output isolation—fundamental challenges in optical information processing. We also implement low-level spike-processing tasks that are critical for higher level processing: temporal pattern detection and stable recurrent memory. We study these properties in the context of a fiber laser system and also propose and simulate an analogous integrated device. The addition of graphene leads to a number of advantages which stem from its unique properties, including high absorption and fast carrier relaxation. These could lead to significant speed and efficiency improvements in unconventional laser processing devices, and ongoing research on graphene microfabrication promises compatibility with integrated laser platforms. PMID:26753897

  20. A programmable nanoreplica molding for the fabrication of nanophotonic devices

    PubMed Central

    Liu, Longju; Zhang, Jingxiang; Badshah, Mohsin Ali; Dong, Liang; Li, Jingjing; Kim, Seok-min; Lu, Meng

    2016-01-01

    The ability to fabricate periodic structures with sub-wavelength features has a great potential for impact on integrated optics, optical sensors, and photovoltaic devices. Here, we report a programmable nanoreplica molding process to fabricate a variety of sub-micrometer periodic patterns using a single mold. The process utilizes a stretchable mold to produce the desired periodic structure in a photopolymer on glass or plastic substrates. During the replica molding process, a uniaxial force is applied to the mold and results in changes of the periodic structure, which resides on the surface of the mold. Direction and magnitude of the force determine the array geometry, including the lattice constant and arrangement. By stretching the mold, 2D arrays with square, rectangular, and triangular lattice structures can be fabricated. As one example, we present a plasmonic crystal device with surface plasmon resonances determined by the force applied during molding. In addition, photonic crystal slabs with different array patterns are fabricated and characterized. This unique process offers the capability of generating various periodic nanostructures rapidly and inexpensively. PMID:26925828

  1. Ideas for Use of an IPad in Introductory Physics Education

    NASA Astrophysics Data System (ADS)

    Aurora, Tarlok S.

    2014-03-01

    Mobile devices such as an IPad, tablet computers and smartphones offer an opportunity to collect information to facilitate physics teaching and learning. The data collected with built-in sensors, such as a video camera, may be analyzed on the mobile device itself or on a desktop computer. In this work, first, the circular motion of a steel ball rolling in a cereal bowl was analyzed to show that it consisted of two simple harmonic motions, in perpendicular directions. Secondly, motion of two balls-one dropped vertically down, and the other one launched as a projectile - was analyzed. Data was analyzed with Logger Pro software, and value of g was determined graphically. Details of the work, its limitations and additional examples will be described. The material so obtained may be used as a demonstration, in a classroom, to clarify physics concepts. In a school, where students are required to have such portable devices, one may assign such activities as homework, to enhance student engagement in learning physics. The author is thankful to USciences for the IPad; and Rich Cosgriff, Phyllis Blumberg and Elia Eschenazi for useful discussions.

  2. Ionic Liquid Activation of Amorphous Metal-Oxide Semiconductors for Flexible Transparent Electronic Devices

    DOE PAGES

    Pudasaini, Pushpa Raj; Noh, Joo Hyon; Wong, Anthony T.; ...

    2016-02-09

    To begin this abstract, amorphous metal-oxide semiconductors offer the high carrier mobilities and excellent large-area uniformity required for high performance, transparent, flexible electronic devices; however, a critical bottleneck to their widespread implementation is the need to activate these materials at high temperatures which are not compatible with flexible polymer substrates. The highly controllable activation of amorphous indium gallium zinc oxide semiconductor channels using ionic liquid gating at room temperature is reported. Activation is controlled by electric field-induced oxygen migration across the ionic liquid-semiconductor interface. In addition to activation of unannealed devices, it is shown that threshold voltages of a transistormore » can be linearly tuned between the enhancement and depletion modes. Finally, the first ever example of transparent flexible thin film metal oxide transistor on a polyamide substrate created using this simple technique is demonstrated. Finally, this study demonstrates the potential of field-induced activation as a promising alternative to traditional postdeposition thermal annealing which opens the door to wide scale implementation into flexible electronic applications.« less

  3. Design and Performance Evaluation of Sensors and Actuators for Advanced Optical Systems

    NASA Technical Reports Server (NTRS)

    Clark, Natalie

    2011-01-01

    Current state-of-the-art commercial sensors and actuators do not meet many of NASA s next generation spacecraft and instrument needs. Nor do they satisfy the DoD needs for satellite missions, especially micro/nano satellite missions. In an effort to develop advanced optical devices and instruments that meet mission requirements, NASA Langley recently completed construction of a new cleanroom housing equipment capable of fabricating high performance active optic and adaptive optic technologies including deformable mirrors, reconfigurable lenses (both refractive and diffractive), spectrometers, spectro-polarimeters, tunable filters and many other active optic devices. In addition to performance, these advanced optic technologies offer advantages in speed, size, weight, power consumption, and radiation tolerance. The active optic devices described in this paper rely on birefringent liquid crystal materials to alter either the phase or the polarization of the incoming light. Design considerations and performance evaluation results for various NASA applications are presented. Applications presented will include large space telescopes, optical communications, spacecraft windows, coronagraphs, and star trackers. Keywords: Photonics, Adaptive Optics, Tunable Filters, MEMs., MOEMs, Coronagraph, Star Tracker

  4. Lightweight multi-carrier modulation for IoT

    NASA Astrophysics Data System (ADS)

    Hussein, Ahmed F.; Elgala, Hany

    2018-01-01

    Visible light communications (VLC) based on intensity-modulation with direct-detection (IM/DD) is a promising technology to offer broadband wireless Internet access. A VLC system based on the well-known multi-carrier orthogonal frequency-division multiplexing (OFDM) modulation has the potential to coexist with radio frequency (RF) technologies such as WiFi. Recently, the VLC technology is considered to enable wireless connectivity of resource limited devices, thus enabling the Internet-of-Things (IoT) vision. This paper presents a novel concept for modulating multiple light sources to realize a lightweight version of OFDM communication chain suitable for resource limited IoT devices. In such proposed system, different sinusoidal streams from an array of light sources are carrying the encoded OFDM time-domain samples, thus enabling the realization of the Fourier transformation in the optical domain. Accordingly, the fast Fourier transform (FFT) operation required for the demodulation at the receiver side is eliminated, which is crucial for resource limited IoT devices. In addition, the proposed concept, (1) offers the same spectral efficiency as the well-known asymmetrically clipped optical OFDM (ACO-OFDM), (2) reduces the bandwidth requirement from individual light sources, (3) reduces the peak-to-average power ratio (PAPR) of the signal formed and transmitted over the optical channel, and (4) supports simultaneous sensing applications using the different sinusoidal streams that are acting as unique beaconing signals. The proposed concept is numerically evaluated and compared with ACO-OFDM. The obtained results reveal a clear reduction in the PAPR with ˜ 5dB at a complementary cumulative distribution function (CCDF) of 10-2 and remarkable enhancement in bit-error performance.

  5. Multifrequency sources of quantum correlated photon pairs on-chip: a path toward integrated Quantum Frequency Combs

    NASA Astrophysics Data System (ADS)

    Caspani, Lucia; Reimer, Christian; Kues, Michael; Roztocki, Piotr; Clerici, Matteo; Wetzel, Benjamin; Jestin, Yoann; Ferrera, Marcello; Peccianti, Marco; Pasquazi, Alessia; Razzari, Luca; Little, Brent E.; Chu, Sai T.; Moss, David J.; Morandotti, Roberto

    2016-06-01

    Recent developments in quantum photonics have initiated the process of bringing photonic-quantumbased systems out-of-the-lab and into real-world applications. As an example, devices to enable the exchange of a cryptographic key secured by the laws of quantum mechanics are already commercially available. In order to further boost this process, the next step is to transfer the results achieved by means of bulky and expensive setups into miniaturized and affordable devices. Integrated quantum photonics is exactly addressing this issue. In this paper, we briefly review the most recent advancements in the generation of quantum states of light on-chip. In particular, we focus on optical microcavities, as they can offer a solution to the problem of low efficiency that is characteristic of the materials typically used in integrated platforms. In addition, we show that specifically designed microcavities can also offer further advantages, such as compatibility with telecom standards (for exploiting existing fibre networks) and quantum memories (necessary to extend the communication distance), as well as giving a longitudinal multimode character for larger information transfer and processing. This last property (i.e., the increased dimensionality of the photon quantum state) is achieved through the ability to generate multiple photon pairs on a frequency comb, corresponding to the microcavity resonances. Further achievements include the possibility of fully exploiting the polarization degree of freedom, even for integrated devices. These results pave the way for the generation of integrated quantum frequency combs that, in turn, may find important applications toward the realization of a compact quantum-computing platform.

  6. Refractive index sensor based on combination of tilted fiber Bragg grating and waist-enlarged fusion bitaper

    NASA Astrophysics Data System (ADS)

    Liu, Xiaohang; Zheng, Jie; Yang, Jingyi; Li, Yi; Dong, Xinyong

    2015-12-01

    Refractive index measurement by using the combination of a tilted fiber Bragg grating (TFBG) and a waist-enlarged fusion bitaper (WEFBT) is proposed and demonstrated. The both devices can couple light between core and cladding modes with coupling coefficients depending on ambient refractive index. It is found that the proposed refractive index sensor offers two measurement ranges respectively from 1.333 to 1.428 and from 1.383 to 1.453 when different sensing segment is used, in addition to advantages of reflection operation mode and intensity-modulated measurement.

  7. The Physics of Ultracold Sr2 Molecules: Optical Production and Precision Measurement

    NASA Astrophysics Data System (ADS)

    Osborn, Christopher Butler

    Colloidal quantum dots have desirable optical properties which can be exploited to realize a variety of photonic devices and functionalities. However, colloidal dots have not had a pervasive utility in photonic devices because of the absence of patterning methods. The electronic chip industry is highly successful due to the well-established lithographic procedures. In this thesis we borrow ideas from the semiconductor industry to develop lithographic techniques that can be used to pattern colloidal quantum dots while ensuring that the optical properties of the quantum dots are not affected by the process. In this thesis we have developed colloidal quantum dot based waveguide structures for amplification and switching applications for all-optical signal processing. We have also developed colloidal quantum dot based light emitting diodes. We successfully introduced CdSe/ZnS quantum dots into a UV curable photo-resist, which was then patterned to realize active devices. In addition, "passive" devices (devices without quantum dots) were integrated to "active" devices via waveguide couplers. Use of photo-resist devices offers two distinct advantages. First, they have low scattering loss and secondly, they allow good fiber to waveguide coupling efficiency due to the low refractive index which allows for large waveguide cross-sections while supporting single mode operation. Practical planar photonic devices and circuits incorporating both active and passive structures can now be realized, now that we have patterning capabilities of quantum dots while maintaining the original optical attributes of the system. In addition to the photo-resist host, we also explored the incorporation of colloidal quantum dots into a dielectric silicon dioxide and silicon nitride one-dimensional microcavity structures using low temperature plasma enhanced chemical vapor deposition. This material system can be used to realize microcavity light emitting diodes that can be realized on any substrate. As a proof of concept demonstration we show a 1550 nm emitting all-dielectric vertical cavity structure embedded with PbS quantum dots. Enhancement in spontaneous emission from the dots embedded in the microcavity is also demonstrated.

  8. Objective Comparison of Commercially Available Breast Implant Devices.

    PubMed

    Henderson, Peter W; Nash, David; Laskowski, Marta; Grant, Robert T

    2015-10-01

    Breast implants are frequently used for both cosmetic breast augmentation and breast reconstruction after mastectomy. Three companies currently offer FDA-approved breast implants (Allergan, Mentor, and Sientra), but their product offerings-including permanent breast implants, breast tissue expanders, sizers, and post-operative warranty-can be difficult to compare because of brand names and company-specific jargon. The ability to have a brand-agnostic understanding of all available options is important for both the surgical trainee as well as the surgeon in clinical practice. After a brief review of the history of breast implant devices, this review utilizes a unique conceptual framework based on variables such as fill material, shape, relative dimensions, and surface coating to facilitate a better understanding of the similarities and differences between the different company's offerings. Specifically, we identify which types of devices are offered by all three companies, those that are offered by only one company, those that have very limited product offerings, and those combinations that are not available at all. Finally, clinical implications are drawn from this framework that can be used by both cosmetic and reconstructive surgeons to counsel patients about all available options. Importantly, this project is entirely independent of any company's funding, support, or input. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  9. Photonic crystal resonances for sensing and imaging

    NASA Astrophysics Data System (ADS)

    Pitruzzello, Giampaolo; Krauss, Thomas F.

    2018-07-01

    This review provides an insight into the recent developments of photonic crystal (PhC)-based devices for sensing and imaging, with a particular emphasis on biosensors. We focus on two main classes of devices, namely sensors based on PhC cavities and those on guided mode resonances (GMRs). This distinction is able to capture the richness of possibilities that PhCs are able to offer in this space. We present recent examples highlighting applications where PhCs can offer new capabilities, open up new applications or enable improved performance, with a clear emphasis on the different types of structures and photonic functions. We provide a critical comparison between cavity-based devices and GMR devices by highlighting strengths and weaknesses. We also compare PhC technologies and their sensing mechanism to surface plasmon resonance, microring resonators and integrated interferometric sensors.

  10. Can Braille be revived? A possible impact of high-end Braille and mainstream technology on the revival of tactile literacy medium.

    PubMed

    Wiazowski, Jaroslaw

    2014-01-01

    With a decline in use of Braille, very few attractive technological options can be offered to young learners. Various research data confirm that teachers of the visually impaired do not have sufficient skills to introduce their students to modern devices. The Mountbatten Brailler can be considered as a tool that combines Braille technology with mainstream tools commonly used by students and teachers. This combination of devices opens new possibilities for the teachers and their students to reverse the trend in the use of Braille. Thanks to features offered by the Brailler and iOS devices, sighted and blind users receive a tool for unimpaired written communication.

  11. Optimization of monolithic columns for microfluidic devices

    NASA Astrophysics Data System (ADS)

    Pagaduan, Jayson V.; Yang, Weichun; Woolley, Adam T.

    2011-06-01

    Monolithic columns offer advantages as solid-phase extractors because they offer high surface area that can be tailored to a specific function, fast mass transport, and ease of fabrication. Porous glycidyl methacrylate-ethylene glycol dimethacrylate monoliths were polymerized in-situ in microfluidic devices, without pre-treatment of the poly(methyl methacrylate) channel surface. Cyclohexanol, 1-dodecanol and Tween 20 were used to control the pore size of the monoliths. The epoxy groups on the monolith surface can be utilized to immobilize target-specific probes such as antibodies, aptamers, or DNA for biomarker detection. Microfluidic devices integrated with solid-phase extractors should be useful for point-of-care diagnostics in detecting specific biomarkers from complex biological fluids.

  12. Hole-Impeded-Doping-Superlattice LWIR Detectors

    NASA Technical Reports Server (NTRS)

    Maserjian, Joseph

    1991-01-01

    Hole-Impeded-Doping-Superlattice (HIDS) InAs devices proposed for use as photoconductive or photovoltaic detectors of radiation in long-wavelength infrared (LWIR) range of 8 to 17 micrometers. Array of HIDS devices fabricated on substrates GaAs or Si. Radiation incident on black surface, metal contacts for picture elements serve as reactors, effectively doubling optical path and thereby increasing absorption of photons. Photoconductive detector offers advantages of high gain and high impedance; photovoltaic detector offers lower noise and better interface to multiplexer readouts.

  13. Surgical and Technical Modalities for Hearing Restoration in Ear Malformations.

    PubMed

    Dazert, Stefan; Thomas, Jan Peter; Volkenstein, Stefan

    2015-12-01

    Malformations of the external and middle ear often go along with an aesthetic and functional handicap. Independent of additional aesthetic procedures, a successful functional hearing restoration leads to a tremendous gain in quality of life for affected patients. The introduction of implantable hearing systems (bone conduction and middle ear devices) offers new therapeutic options in this field. We focus on functional rehabilitation of patients with malformations, either by surgical reconstruction or the use of different implantable hearing devices, depending on the disease itself and the severity of malformation as well as hearing impairment. Patients with an open ear canal and minor malformations are good candidates for surgical hearing restoration of middle ear structures with passive titanium or autologous implants. In cases with complete fibrous or bony atresia of the ear canal, the most promising functional outcome and gain in quality of life can be expected with an active middle ear implant or a bone conduction device combined with a surgical aesthetic rehabilitation in a single or multi-step procedure. Although the surgical procedure for bone conduction devices is straightforward and safe, more sophisticated operations for active middle ear implants (e.g., Vibrant Soundbridge, MED-EL, Innsbruck, Austria) provide an improved speech discrimination in noise and the ability of sound localization compared with bone conduction devices where the stimulation reaches both cochleae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Inkjet 3D printing of UV and thermal cure silicone elastomers for dielectric elastomer actuators

    NASA Astrophysics Data System (ADS)

    McCoul, David; Rosset, Samuel; Schlatter, Samuel; Shea, Herbert

    2017-12-01

    Dielectric elastomer actuators (DEAs) are an attractive form of electromechanical transducer, possessing high energy densities, an efficient design, mechanical compliance, high speed, and noiseless operation. They have been incorporated into a wide variety of devices, such as microfluidic systems, cell bioreactors, tunable optics, haptic displays, and actuators for soft robotics. Fabrication of DEA devices is complex, and the majority are inefficiently made by hand. 3D printing offers an automated and flexible manufacturing alternative that can fabricate complex, multi-material, integrated devices consistently and in high resolution. We present a novel additive manufacturing approach to DEA devices in which five commercially available, thermal and UV-cure DEA silicone rubber materials have been 3D printed with a drop-on-demand, piezoelectric inkjet system. Using this process, 3D structures and high-quality silicone dielectric elastomer membranes as thin as 2 μm have been printed that exhibit mechanical and actuation performance at least as good as conventionally blade-cast membranes. Printed silicone membranes exhibited maximum tensile strains of up to 727%, and DEAs with printed silicone dielectrics were actuated up to 6.1% area strain at a breakdown strength of 84 V μm-1 and also up to 130 V μm-1 at 2.4% strain. This approach holds great potential to manufacture reliable, high-performance DEA devices with high throughput.

  15. A rugged 650 V SOI-based high-voltage half-bridge IGBT gate driver IC for motor drive applications

    NASA Astrophysics Data System (ADS)

    Hua, Qing; Li, Zehong; Zhang, Bo; Chen, Weizhong; Huang, Xiangjun; Feng, Yuxiang

    2015-05-01

    This paper proposes a rugged high-voltage N-channel insulated gate bipolar transistor (IGBT) gate driver integrated circuit. The device integrates a high-side and a low-side output stages on a single chip, which is designed specifically for motor drive applications. High-voltage level shift technology enables the high-side stage of this device to operate up to 650 V. The logic inputs are complementary metal oxide semiconductor (CMOS)/transistor transistor logic compatible down to 3.3 V. Undervoltage protection functionality with hysteresis characteristic has also been integrated to enhance the device reliability. The device is fabricated in a 1.0 μm, 650 V high-voltage bipolar CMOS double-diffused metal oxide semiconductor (BCD) on silicon-on-insulator (SOI) process. Deep trench dielectric isolation technology is employed to provide complete electrical isolation with advantages such as reduced parasitic effects, excellent noise immunity and low leakage current. Experimental results show that the isolation voltage of this device can be up to approximately 779 V at 25°C, and the leakage current is only 5 nA at 650 V, which is 15% higher and 67% lower than the conventional ones. In addition, it delivers an excellent thermal stability and needs very low quiescent current and offers a high gate driver capability which is needed to adequately drive IGBTs that have large input capacitances.

  16. A multi-channel clogging-resistant lab-on-a-chip cell counter and analyzer

    NASA Astrophysics Data System (ADS)

    Dai, Jie; Chiu, Yu-Jui; Lian, Ian; Wu, Tsung-Feng; Yang, Kecheng; Lo, Yu-Hwa

    2016-02-01

    Early signs of diseases can be revealed from cell detection in biofluids, such as detection of white blood cells (WBCs) in the peritoneal fluid for peritonitis. A lab-on-a-chip microfluidic device offers an attractive platform for such applications because of its small size, low cost, and ease of use provided the device can meet the performance requirements which many existing LoC devices fail to satisfy. We report an integrated microfluidic device capable of accurately counting low concentration of white blood cells in peritoneal fluid at 150 μl min-1 to offer an accurate (<3% error) and fast (~10 min/run) WBC count. Utilizing the self-regulating hydrodynamic properties and a unique architecture in the design, the device can achieve higher flow rate (500-1000 μl min-1), continuous running for over 5 h without clogging, as well as excellent signal quality for unambiguous WBC count and WBC classification for certain diseases. These properties make the device a promising candidate for point-of-care applications.

  17. Public-use blood pressure measurement: the kiosk quandary.

    PubMed

    Alpert, Bruce S; Dart, Richard A; Sica, Domenic A

    2014-10-01

    It is important to note the opportunity that validated public-use kiosks offer the U.S. healthcare system in terms of ease of public access, reduced cost of screening/monitoring, and the opportunity to support coordinated care between physicians, pharmacists, and patients. It is equally important to recognize that all public-use BP kiosks are not equivalent. Members of the AAMI Sphygmomanometer Committee and other ‘‘concerned citizens’’ are working with FDA officials to try to improve both device validation and cuff range performance of these devices. In reality, regulatory changes will be slow to take effect, and for the foreseeable future, the burden of device accuracy assessment lies with the private sector and the public. There is a device currently available that has undergone full validation testing and offers a wide-range cuff validated for almost all US adult arms. We recognize the importance of innovation in out-of-office BP measurement. Therefore, in the interest of public health, we strongly urge those business professionals buying such devices, and those health professionals advising patients on their use, to become better informed and more discriminant in their device selection.

  18. 75 FR 27264 - Video Device Competition; Implementation of Section 304 of the Telecommunications Act of 1996...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-14

    ... and Consumer Electronics Equipment AGENCY: Federal Communications Commission. ACTION: Notice of... explore the potential for allowing any electronics manufacturer to offer smart video devices at retail...

  19. Tackling the challenges of fully immersive head-mounted AR devices

    NASA Astrophysics Data System (ADS)

    Singer, Wolfgang; Hillenbrand, Matthias; Münz, Holger

    2017-11-01

    The optical requirements of fully immersive head mounted AR devices are inherently determined by the human visual system. The etendue of the visual system is large. As a consequence, the requirements for fully immersive head-mounted AR devices exceeds almost any high end optical system. Two promising solutions to achieve the large etendue and their challenges are discussed. Head-mounted augmented reality devices have been developed for decades - mostly for application within aircrafts and in combination with a heavy and bulky helmet. The established head-up displays for applications within automotive vehicles typically utilize similar techniques. Recently, there is the vision of eyeglasses with included augmentation, offering a large field of view, and being unobtrusively all-day wearable. There seems to be no simple solution to reach the functional performance requirements. Known technical solutions paths seem to be a dead-end, and some seem to offer promising perspectives, however with severe limitations. As an alternative, unobtrusively all-day wearable devices with a significantly smaller field of view are already possible.

  20. Microfluidics on compliant substrates: recent developments in foldable and bendable devices and system packaging

    NASA Astrophysics Data System (ADS)

    Gray, Bonnie L.

    2012-04-01

    Microfluidics is revolutionizing laboratory methods and biomedical devices, offering new capabilities and instrumentation in multiple areas such as DNA analysis, proteomics, enzymatic analysis, single cell analysis, immunology, point-of-care medicine, personalized medicine, drug delivery, and environmental toxin and pathogen detection. For many applications (e.g., wearable and implantable health monitors, drug delivery devices, and prosthetics) mechanically flexible polymer devices and systems that can conform to the body offer benefits that cannot be achieved using systems based on conventional rigid substrate materials. However, difficulties in implementing active devices and reliable packaging technologies have limited the success of flexible microfluidics. Employing highly compliant materials such as PDMS that are typically employed for prototyping, we review mechanically flexible polymer microfluidic technologies based on free-standing polymer substrates and novel electronic and microfluidic interconnection schemes. Central to these new technologies are hybrid microfabrication methods employing novel nanocomposite polymer materials and devices. We review microfabrication methods using these materials, along with demonstrations of example devices and packaging schemes that employ them. We review these recent developments and place them in the context of the fields of flexible microfluidics and conformable systems, and discuss cross-over applications to conventional rigid-substrate microfluidics.

  1. Provision of magnetic resonance imaging for patients with 'MR-conditional' cardiac implantable electronic devices: an unmet clinical need.

    PubMed

    Sabzevari, Kian; Oldman, James; Herrey, Anna S; Moon, James C; Kydd, Anna C; Manisty, Charlotte

    2017-03-01

    Increasing need for magnetic resonance imaging (MRI) has driven the development of MR-conditional cardiac implantable electronic devices (CIEDs; pacemakers and defibrillators); however, patients still report difficulties obtaining scans. We sought to establish current provision for MRI scanning of patients with CIEDs in England. A survey was distributed to all hospitals in England with MRI, to assess current practice. Information requested included whether hospitals currently offer MRI to this patient group, the number and type of scans acquired, local safety considerations, complications experienced and perceived obstacles to service provision in those departments not currently offering it. Responses were received from 195 of 227 (86%) of hospitals surveyed. Although 98% of departments were aware of MR-conditional devices, only 46% (n = 89) currently offer MRI scans to patients with CIED's; of these, 85% of departments perform ≤10 scans per year. No major complications were reported from MRI scanning in patients with MR-conditional devices. Current barriers to service expansion include perceived concerns regarding potential risk, lack of training, logistical difficulties, and lack of cardiology support. Provision of MRI for patients with CIEDs is currently poor, despite increasing numbers of patients with MR-conditional devices and extremely low reported complication rates. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  2. High Aspect Ratio Semiconductor Heterojunction Solar Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Redwing, Joan; Mallouk, Tom; Mayer, Theresa

    2013-05-17

    The project focused on the development of high aspect ratio silicon heterojunction (HARSH) solar cells. The solar cells developed in this study consisted of high density vertical arrays of radial junction silicon microwires/pillars formed on Si substrates. Prior studies have demonstrated that vertical Si wire/pillar arrays enable reduced reflectivity and improved light trapping characteristics compared to planar solar cells. In addition, the radial junction structure offers the possibility of increased carrier collection in solar cells fabricated using material with short carrier diffusion lengths. However, the high junction and surface area of radial junction Si wire/pillar array devices can be problematicmore » and lead to increased diode leakage and enhanced surface recombination. This study investigated the use of amorphous hydrogenated Si in the form of a heterojunction-intrinsic-thin layer (HIT) structure as a junction formation method for these devices. The HIT layer structure has widely been employed to reduce surface recombination in planar crystalline Si solar cells. Consequently, it was anticipated that it would also provide significant benefits to the performance of radial junction Si wire/pillar array devices. The overall goals of the project were to demonstrate a HARSH cell with a HIT-type structure in the radial junction Si wire/pillar array configuration and to develop potentially low cost pathways to fabricate these devices. Our studies demonstrated that the HIT structure lead to significant improvements in the open circuit voltage (V oc>0.5) of radial junction Si pillar array devices compared to devices fabricated using junctions formed by thermal diffusion or low pressure chemical vapor deposition (LPCVD). In addition, our work experimentally demonstrated that the radial junction structure lead to improvements in efficiency compared to comparable planar devices for devices fabricated using heavily doped Si that had reduced carrier diffusion lengths. Furthermore, we made significant advances in employing the bottom-up vapor-liquid-solid (VLS) growth technique for the fabrication of the Si wire arrays. Our work elucidated the effects of growth conditions and substrate pattern geometry on the growth of large area Si microwire arrays grown with SiCl4. In addition, we also developed a process to grow p-type Si nanowire arrays using aluminum as the catalyst metal instead of gold. Finally, our work demonstrated the feasibility of growing vertical arrays of Si wires on non-crystalline glass substrates using polycrystalline Si template layers. The accomplishments demonstrated in this project will pave the way for future advances in radial junction wire array solar cells.« less

  3. Smart image sensors: an emerging key technology for advanced optical measurement and microsystems

    NASA Astrophysics Data System (ADS)

    Seitz, Peter

    1996-08-01

    Optical microsystems typically include photosensitive devices, analog preprocessing circuitry and digital signal processing electronics. The advances in semiconductor technology have made it possible today to integrate all photosensitive and electronical devices on one 'smart image sensor' or photo-ASIC (application-specific integrated circuits containing photosensitive elements). It is even possible to provide each 'smart pixel' with additional photoelectronic functionality, without compromising the fill factor substantially. This technological capability is the basis for advanced cameras and optical microsystems showing novel on-chip functionality: Single-chip cameras with on- chip analog-to-digital converters for less than $10 are advertised; image sensors have been developed including novel functionality such as real-time selectable pixel size and shape, the capability of performing arbitrary convolutions simultaneously with the exposure, as well as variable, programmable offset and sensitivity of the pixels leading to image sensors with a dynamic range exceeding 150 dB. Smart image sensors have been demonstrated offering synchronous detection and demodulation capabilities in each pixel (lock-in CCD), and conventional image sensors are combined with an on-chip digital processor for complete, single-chip image acquisition and processing systems. Technological problems of the monolithic integration of smart image sensors include offset non-uniformities, temperature variations of electronic properties, imperfect matching of circuit parameters, etc. These problems can often be overcome either by designing additional compensation circuitry or by providing digital correction routines. Where necessary for technological or economic reasons, smart image sensors can also be combined with or realized as hybrids, making use of commercially available electronic components. It is concluded that the possibilities offered by custom smart image sensors will influence the design and the performance of future electronic imaging systems in many disciplines, reaching from optical metrology to machine vision on the factory floor and in robotics applications.

  4. Dynamically tunable graphene/dielectric photonic crystal transmission lines

    NASA Astrophysics Data System (ADS)

    Williamson, Ian; Mousavi, S. Hossein; Wang, Zheng

    2015-03-01

    It is well known that graphene supports plasmonic modes with high field confinement and lower losses when compared to conventional metals. Additionally, graphene features a highly tunable conductivity through which the plasmon dispersion can be modulated. Over the years these qualities have inspired a wide range of applications for graphene in the THz and infrared regimes. In this presentation we theoretically demonstrate a graphene parallel plate waveguide (PPWG) that sandwiches a 2D photonic crystal slab. The marriage of these two geometries offers a large two dimensional band gap that can be dynamically tuned over a very broad bandwidth. Our device operates in the low-THz band where the graphene PPWG supports a quasi-TEM mode with a relatively flat attenuation. Unlike conventional photonic crystal slabs, the quasi-TEM nature of the graphene PPWG mode allows the slab thickness to be less than 1/10 of the photonic crystal lattice constant. These features offer up a wealth of opportunities, including tunable metamaterials with a possible platform for large band gaps in 3D structures through tiling and stacking. Additionally, the geometry provides a platform for tunable defect cavities without needing three dimensional periodicity.

  5. A high-sensitivity optical device for the early monitoring of plant pathogen attack via the in vivo detection of ROS bursts

    PubMed Central

    Zeng, Lizhang; Zhou, Jun; Li, Bo; Xing, Da

    2015-01-01

    Biotic stressors, especially pathogenic microorganisms, are rather difficult to detect. In plants, one of the earliest cellular responses following pathogen infection is the production of reactive oxygen species (ROS). In this study, a novel optical device for the early monitoring of Pseudomonas attack was developed; this device measures the ROS level via oxidation-sensitive 2′, 7′-dichlorodihydrofluorescein diacetate (H2DCFDA)-mediated fluorescence, which could provide early monitoring of attacks by a range of plant pathogen; ROS bursts were detected in vivo in Arabidopsis thaliana with higher sensitivity and accuracy than those of a commercial luminescence spectrophotometer. Additionally, the DCF fluorescence truly reflected early changes in the ROS level, as indicated by an evaluation of the H2O2 content and the tight association between the ROS and Pseudomonas concentration. Moreover, compared with traditional methods for detecting plant pathogen attacks based on physiological and biochemical measurements, our proposed technique also offers significant advantages, such as low cost, simplicity, convenient operation and quick turnaround. These results therefore suggest that the proposed optical device could be useful for the rapid monitoring of attacks by plant pathogen and yield results considerably earlier than the appearance of visual changes in plant morphology or growth. PMID:25767474

  6. Electrical Tuning of Exciton-Plasmon Polariton Coupling in Monolayer MoS2 Integrated with Plasmonic Nanoantenna Lattice.

    PubMed

    Lee, Bumsu; Liu, Wenjing; Naylor, Carl H; Park, Joohee; Malek, Stephanie C; Berger, Jacob S; Johnson, A T Charlie; Agarwal, Ritesh

    2017-07-12

    Active control of light-matter interactions in semiconductors is critical for realizing next generation optoelectronic devices with real-time control of the system's optical properties and hence functionalities via external fields. The ability to dynamically manipulate optical interactions by applied fields in active materials coupled to cavities with fixed geometrical parameters opens up possibilities of controlling the lifetimes, oscillator strengths, effective mass, and relaxation properties of a coupled exciton-photon (or plasmon) system. Here, we demonstrate electrical control of exciton-plasmon coupling strengths between strong and weak coupling limits in a two-dimensional semiconductor integrated with plasmonic nanoresonators assembled in a field-effect transistor device by electrostatic doping. As a result, the energy-momentum dispersions of such an exciton-plasmon coupled system can be altered dynamically with applied electric field by modulating the excitonic properties of monolayer MoS 2 arising from many-body effects. In addition, evidence of enhanced coupling between charged excitons (trions) and plasmons was also observed upon increased carrier injection, which can be utilized for fabricating Fermionic polaritonic and magnetoplasmonic devices. The ability to dynamically control the optical properties of a coupled exciton-plasmonic system with electric fields demonstrates the versatility of the coupled system and offers a new platform for the design of optoelectronic devices with precisely tailored responses.

  7. Current evidence for the use of C-MAC videolaryngoscope in adult airway management: a review of the literature

    PubMed Central

    Xue, Fu-Shan; Li, Hui-Xian; Liu, Ya-Yang; Yang, Gui-Zhen

    2017-01-01

    The C-MAC videolaryngoscope is the first Macintosh-typed videolaryngoscope. Since the advent of its original version video Macintosh system in 1999, this device has been modified several times. A unique feature of C-MAC device is its ability to provide the 2 options of direct and video laryngoscopy with the same device. The available evidence shows that in patients with normal airways, C-MAC videolaryngoscope compared with direct laryngoscopy can provide comparable or better laryngeal views and exerts less force on maxillary incisors, but does not offer conclusive benefits with regard to intubation time, intubation success, number of intubation attempts, the use of adjuncts, and hemodynamic responses to intubation. In patients with predicted or known difficult airways, C-MAC videolaryngoscope can achieve a better laryngeal view, a higher intubation success rate and a shorter intubation time than direct laryngoscopy. Furthermore, the option to perform direct and video laryngoscopy with the same device makes C-MAC videolaryngoscope exceptionally useful for emergency intubation. In addition, the C-MAC videolaryngoscope is a very good tool for tracheal intubation teaching. However, tracheal intubation with C-MAC videolaryngoscope may occasionally fail and introduction of C-MAC videolaryngoscope in clinical practice must be accompanied by formal training programs in normal and difficult airway managements. PMID:28740393

  8. Enhancement-mode two-channel triple quantum dot from an undoped Si/Si0.8Ge0.2 quantum well hetero-structure.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Studenikin, S. A.; Gaudreau, L.; Kataoka, K.

    We demonstrate coupled triple dot operation and charge sensing capability for the recently introduced quantum dot technology employing undoped Si/Si 0.8Ge 0.2 hetero-structures which also incorporate a single metal-gate layer to simplify fabrication [T. M. Lu et al., Appl. Phys. Lett. 109, 093102 (2016)]. Si/SiGe hetero-structures with a Ge concentration of 20% rather than the more usual 30% typically encountered offer higher electron mobility. The devices consist of two in-plane parallel electron channels that host a double dot in one channel and a single dot in the other channel. In a device where the channels are sufficiently close a triplemore » dot in a triangular configuration is induced leading to regions in the charge stability diagram where three addition lines of different slope approach each other and anti-cross. In a device where the channels are further apart the single dot charge-senses the double dot with relative change of ~2% in the sensor current. We also highlight temporal drifting and metastability of the Coulomb oscillations. These effects are induced if the temperature environment of the device is not kept constant and arise from non-equilibrium charge redistribution and subsequent slow recovery.« less

  9. Integrated MEMS-based variable optical attenuator and 10Gb/s receiver

    NASA Astrophysics Data System (ADS)

    Aberson, James; Cusin, Pierre; Fettig, H.; Hickey, Ryan; Wylde, James

    2005-03-01

    MEMS devices can be successfully commercialized in favour of competing technologies only if they offer an advantage to the customer in terms of lower cost or increased functionality. There are limited markets where MEMS can be manufactured cheaper than similar technologies due to large volumes: automotive, printing technology, wireless communications, etc. However, success in the marketplace can also be realized by adding significant value to a system at minimal cost or leverging MEMS technology when other solutions simply will not work. This paper describes a thermally actuated, MEMS based, variable optical attenuator that is co-packaged with existing opto-electronic devices to develop an integrated 10Gb/s SONET/SDH receiver. The configuration of the receiver opto-electronics and relatively low voltage availability (12V max) in optical systems bar the use of LCD, EO, and electro-chromic style attenuators. The device was designed and fabricated using a silicon-on-insulator (SOI) starting material. The design and performance of the device (displacement, power consumption, reliability, physical geometry) was defined by the receiver parameters geometry. This paper will describe how these design parameters (hence final device geometry) were determined in light of both the MEMS device fabrication process and the receiver performance. Reference will be made to the design tools used and the design flow which was a joint effort between the MEMS vendor and the end customer. The SOI technology offered a robust, manufacturable solution that gave the required performance in a cost-effective process. However, the singulation of the devices required the development of a new singulation technique that allowed large volumes of silicon to be removed during fabrication yet still offer high singulation yields.

  10. Hybrid, Gate-Tunable, van der Waals p–n Heterojunctions from Pentacene and MoS 2

    DOE PAGES

    Jariwala, Deep; Howell, Sarah L.; Chen, Kan-Sheng; ...

    2015-12-18

    The recent emergence of a wide variety of two-dimensional (2D) materials has created new opportunities for device concepts and applications. In particular, the availability of semiconducting transition metal dichalcogenides, in addition to semimetallic graphene and insulating boron nitride, has enabled the fabrication of “all 2D” van der Waals heterostructure devices. Furthermore, the concept of van der Waals heterostructures has the potential to be significantly broadened beyond layered solids. For example, molecular and polymeric organic solids, whose surface atoms possess saturated bonds, are also known to interact via van der Waals forces and thus offer an alternative for scalable integration withmore » 2D materials. Here, we demonstrate the integration of an organic small molecule p-type semiconductor, pentacene, with a 2D n-type semiconductor, MoS2. The resulting p–n heterojunction is gate-tunable and shows asymmetric control over the antiambipolar transfer characteristic. In addition, the pentacene/MoS2 heterojunction exhibits a photovoltaic effect attributable to type II band alignment, which suggests that MoS2 can function as an acceptor in hybrid solar cells.« less

  11. Tunability of p- and n-channel TiOx thin film transistors.

    PubMed

    Peng, Wu-Chang; Chen, Yao-Ching; He, Ju-Liang; Ou, Sin-Liang; Horng, Ray-Hua; Wuu, Dong-Sing

    2018-06-18

    To acquire device-quality TiO x films usually needs high-temperature growth or additional post-thermal treatment. However, both processes make it very difficult to form the p-type TiO x even under oxygen-poor growth condition. With the aid of high energy generated by high power impulse magnetron sputtering (HIPIMS), a highly stable p-type TiO x film with good quality can be achieved. In this research, by varying the oxygen flow rate, p-type γ-TiO and n-type TiO 2 films were both prepared by HIPIMS. Furthermore, p- and n-type thin film transistors employing γ-TiO and TiO 2 as channel layers possess the field-effect carrier mobilities of 0.2 and 0.7 cm 2 /Vs, while their on/off current ratios are 1.7 × 10 4 and 2.5 × 10 5 , respectively. The first presented p-type γ-TiO TFT is a major breakthrough for fabricating the TiO x -based p-n combinational devices. Additionally, our work also confirms HIPIMS offers the possibility of growing both p- and n-type conductive oxides, significantly expanding the practical usage of this technique.

  12. Hybrid, Gate-Tunable, van der Waals p–n Heterojunctions from Pentacene and MoS 2

    DOE PAGES

    Jariwala, Deep; Howell, Sarah L.; Chen, Kan -Sheng; ...

    2015-12-10

    Here, the recent emergence of a wide variety of two-dimensional (2D) materials has created new opportunities for device concepts and applications. In particular, the availability of semiconducting transition metal dichalcogenides, in addition to semimetallic graphene and insulating boron nitride, has enabled the fabrication of “all 2D” van der Waals heterostructure devices. Furthermore, the concept of van der Waals heterostructures has the potential to be significantly broadened beyond layered solids. For example, molecular and polymeric organic solids, whose surface atoms possess saturated bonds, are also known to interact via van der Waals forces and thus offer an alternative for scalable integrationmore » with 2D materials. Here, we demonstrate the integration of an organic small molecule p-type semiconductor, pentacene, with a 2D n-type semiconductor, MoS 2. The resulting p–n heterojunction is gate-tunable and shows asymmetric control over the antiambipolar transfer characteristic. In addition, the pentacene/MoS 2 heterojunction exhibits a photovoltaic effect attributable to type II band alignment, which suggests that MoS 2 can function as an acceptor in hybrid solar cells.« less

  13. Hybrid, Gate-Tunable, van der Waals p–n Heterojunctions from Pentacene and MoS 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jariwala, Deep; Howell, Sarah L.; Chen, Kan -Sheng

    Here, the recent emergence of a wide variety of two-dimensional (2D) materials has created new opportunities for device concepts and applications. In particular, the availability of semiconducting transition metal dichalcogenides, in addition to semimetallic graphene and insulating boron nitride, has enabled the fabrication of “all 2D” van der Waals heterostructure devices. Furthermore, the concept of van der Waals heterostructures has the potential to be significantly broadened beyond layered solids. For example, molecular and polymeric organic solids, whose surface atoms possess saturated bonds, are also known to interact via van der Waals forces and thus offer an alternative for scalable integrationmore » with 2D materials. Here, we demonstrate the integration of an organic small molecule p-type semiconductor, pentacene, with a 2D n-type semiconductor, MoS 2. The resulting p–n heterojunction is gate-tunable and shows asymmetric control over the antiambipolar transfer characteristic. In addition, the pentacene/MoS 2 heterojunction exhibits a photovoltaic effect attributable to type II band alignment, which suggests that MoS 2 can function as an acceptor in hybrid solar cells.« less

  14. Flexural Plate Wave Devices for Chemical Analysis

    DTIC Science & Technology

    1991-04-16

    Naval Research Laboratory Washi..gton. DC 20375-5000 NRL Memorandum Report 6815 AD-A234 129 Flexural Plate Wave Devices for Chemical Analysis JAY W...4. TITLE AND SUBTITLE S. FUNDING NUMBERS Flexural Plate Wave Devices for Chemical Analysis 6. AUTHOR(S) 61-1638-01 Jay W. Grate. Stuart W. Wenzel... ANALYSIS INTRODUCTION Flexural plate wave (FPW) devices offer many attractive features for chemical analysis (1-9). As gravimetric sensors for chemical

  15. FDA MAUDE data on complications with lasers, light sources, and energy-based devices.

    PubMed

    Tremaine, Anne Marie; Avram, Mathew M

    2015-02-01

    It is essential for physicians to be fully informed regarding adverse events and malfunctions associated with medical devices that occur in routine practice. There is limited information on this important issue in the medical literature, and it is mostly based on initial studies and case reports. More advanced knowledge regarding device adverse events is necessary to guide physicians towards providing safe treatments. The FDA requires that manufacturers and device users submit medical device reports (MDRs) for suspected injuries from device use or malfunction. The database of MDRs, entitled Manufacturer and User Facility Device Experience (MAUDE) enables the FDA to monitor device performance and identify potential safety issues. We employed the following search strategy to identify reported adverse events. We searched the MAUDE electronic database on the FDA website in December 2013: http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfmaude/search.cfm We collected all reported cases between 1991 and December 2013. The search terms utilized included a comprehensive list of device manufacturers, specific product names, and the wavelengths/technology of the devices used in the field of dermatology. Our search yielded 1257 MDRs. Forty-five MDRs were excluded due to insufficient data. The data is broken down into the adverse events observed, such as, but not limited to: blistering, burns, scarring, dyschromia, fat loss, and nerve palsy. The MDRs describe the adverse event and attempt to determine if it was related to device malfunction versus operator error. Radiofrequency devices, diode lasers, and intense pulsed light devices were the most commonly reported devices related to injuries. 1257 MDRs, from a myriad of devices used in dermatology, have been reported to the FDA as of December 2013. Despite the underreporting of adverse events, the MAUDE database is an untapped resource of post-market surveillance of medical devices. The database can offer additional information, which combined with the initial device studies and published case reports from our colleagues, will help raise awareness and improve patient safety. © 2015 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.

  16. Electrically tunable organic–inorganic hybrid polaritons with monolayer WS2

    PubMed Central

    Flatten, Lucas C.; Coles, David M.; He, Zhengyu; Lidzey, David G.; Taylor, Robert A.; Warner, Jamie H.; Smith, Jason M.

    2017-01-01

    Exciton-polaritons are quasiparticles consisting of a linear superposition of photonic and excitonic states, offering potential for nonlinear optical devices. The excitonic component of the polariton provides a finite Coulomb scattering cross section, such that the different types of exciton found in organic materials (Frenkel) and inorganic materials (Wannier-Mott) produce polaritons with different interparticle interaction strength. A hybrid polariton state with distinct excitons provides a potential technological route towards in situ control of nonlinear behaviour. Here we demonstrate a device in which hybrid polaritons are displayed at ambient temperatures, the excitonic component of which is part Frenkel and part Wannier-Mott, and in which the dominant exciton type can be switched with an applied voltage. The device consists of an open microcavity containing both organic dye and a monolayer of the transition metal dichalcogenide WS2. Our findings offer a perspective for electrically controlled nonlinear polariton devices at room temperature. PMID:28094281

  17. Vulnerability Assessment of IPv6 Websites to SQL Injection and Other Application Level Attacks

    PubMed Central

    Cho, Ying-Chiang; Pan, Jen-Yi

    2013-01-01

    Given the proliferation of internet connected devices, IPv6 has been proposed to replace IPv4. Aside from providing a larger address space which can be assigned to internet enabled devices, it has been suggested that the IPv6 protocol offers increased security due to the fact that with the large number of addresses available, standard IP scanning attacks will no longer become feasible. However, given the interest in attacking organizations rather than individual devices, most initial points of entry onto an organization's network and their attendant devices are visible and reachable through web crawling techniques, and, therefore, attacks on the visible application layer may offer ways to compromise the overall network. In this evaluation, we provide a straightforward implementation of a web crawler in conjunction with a benign black box penetration testing system and analyze the ease at which SQL injection attacks can be carried out. PMID:24574863

  18. Vulnerability assessment of IPv6 websites to SQL injection and other application level attacks.

    PubMed

    Cho, Ying-Chiang; Pan, Jen-Yi

    2013-01-01

    Given the proliferation of internet connected devices, IPv6 has been proposed to replace IPv4. Aside from providing a larger address space which can be assigned to internet enabled devices, it has been suggested that the IPv6 protocol offers increased security due to the fact that with the large number of addresses available, standard IP scanning attacks will no longer become feasible. However, given the interest in attacking organizations rather than individual devices, most initial points of entry onto an organization's network and their attendant devices are visible and reachable through web crawling techniques, and, therefore, attacks on the visible application layer may offer ways to compromise the overall network. In this evaluation, we provide a straightforward implementation of a web crawler in conjunction with a benign black box penetration testing system and analyze the ease at which SQL injection attacks can be carried out.

  19. [Development of Bluetooth wireless sensors].

    PubMed

    Moor, C; Schwaibold, M; Roth, H; Schöchlin, J; Bolz, A

    2002-01-01

    Wireless communication could help to overcome current obstacles in medical devices and could enable medical services to offer completely new scenarios in health care. The Bluetooth technology which is the upcoming global market leader in wireless communication turned out to be perfectly suited not only for consumer market products but also in the medical environment [1]. It offers a low power, low cost connection in the medium range of 1-100 m with a bandwidth of currently 723.2 kbaud. This paper describes the development of a wireless ECG device and a Pulse Oximeter. Equipped with a Bluetooth port, the measurement devices are enabled to transmit data between the sensor and a Bluetooth-monitor. Therefore, CSR's Bluetooth protocol embedded two-processor and embedded single-processor architecture has been used.

  20. Isothermal DNA origami folding: avoiding denaturing conditions for one-pot, hybrid-component annealing

    NASA Astrophysics Data System (ADS)

    Kopielski, Andreas; Schneider, Anne; Csáki, Andrea; Fritzsche, Wolfgang

    2015-01-01

    The DNA origami technique offers great potential for nanotechnology. Using biomolecular self-assembly, defined 2D and 3D nanoscale DNA structures can be realized. DNA origami allows the positioning of proteins, fluorophores or nanoparticles with an accuracy of a few nanometers and enables thereby novel nanoscale devices. Origami assembly usually includes a thermal denaturation step at 90 °C. Additional components used for nanoscale assembly (such as proteins) are often thermosensitive, and possibly damaged by such harsh conditions. They have therefore to be attached in an extra second step to avoid defects. To enable a streamlined one-step nanoscale synthesis - a so called one-pot folding - an adaptation of the folding procedures is required. Here we present a thermal optimization of this process for a 2D DNA rectangle-shaped origami resulting in an isothermal assembly protocol below 60 °C without thermal denaturation. Moreover, a room temperature protocol is presented using the chemical additive betaine, which is biocompatible in contrast to chemical denaturing approaches reported previously.The DNA origami technique offers great potential for nanotechnology. Using biomolecular self-assembly, defined 2D and 3D nanoscale DNA structures can be realized. DNA origami allows the positioning of proteins, fluorophores or nanoparticles with an accuracy of a few nanometers and enables thereby novel nanoscale devices. Origami assembly usually includes a thermal denaturation step at 90 °C. Additional components used for nanoscale assembly (such as proteins) are often thermosensitive, and possibly damaged by such harsh conditions. They have therefore to be attached in an extra second step to avoid defects. To enable a streamlined one-step nanoscale synthesis - a so called one-pot folding - an adaptation of the folding procedures is required. Here we present a thermal optimization of this process for a 2D DNA rectangle-shaped origami resulting in an isothermal assembly protocol below 60 °C without thermal denaturation. Moreover, a room temperature protocol is presented using the chemical additive betaine, which is biocompatible in contrast to chemical denaturing approaches reported previously. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr04176c

  1. Medical communication companies and industry grants.

    PubMed

    Rothman, Sheila M; Brudney, Karen F; Adair, Whitney; Rothman, David J

    2013-12-18

    Medical communication companies (MCCs) are among the most significant health care stakeholders, supported mainly by drug and device companies. How MCCs share or protect physicians' personal data requires greater transparency. To explore the financial relationships between MCCs and drug and device companies, to describe the characteristics of the large MCCs, and to explore whether they accurately represent themselves to physicians. We combined data from the 2010 grant registries of 14 pharmaceutical and device companies; grouped recipients into categories such as MCCs, academic medical centers, disease-targeted advocacy organizations, and professional associations; and created a master list of 19,272 grants. Determine the distribution of funds from drug and device companies to various entities and assess the characteristics of large MCCs. Of the 6493 recipients of more than $657 million grant awards from drug and device companies, 18 of 363 MCCs received 26%, academic medical centers received 21%, and disease-targeted organizations received 15%. For-profit MCCs received 77% of funds (208 of 363). Among the top 5% of MCCs, 14 of 18 were for-profit. All 18 offered continuing medical education: 14 offered live and 17 offered online CME courses. All required physicians to provide personal data. Ten stated that they shared information with unnamed third parties. Eight stated they did not share information, but almost all added exceptions. None required explicit physician consent to their sharing policies. Medical communication companies receive substantial support from drug and device companies. Physicians who interact with MCCs should be aware that all require personal data from the physician and some share these data with unnamed third parties.

  2. Survey of driver aid devices for improved fuel economy.

    DOT National Transportation Integrated Search

    1976-11-30

    This report presents a brief summarization of available information pertaining to devices offered to aid the driver in improving his driving habits in order to reduce fuel consumption. Principal emphasis is placed on characterizing the available devi...

  3. A Modular Aerospike Engine Design Using Additive Manufacturing

    NASA Technical Reports Server (NTRS)

    Peugeot, John; Garcia, Chance; Burkhardt, Wendel

    2014-01-01

    A modular aerospike engine concept has been developed with the objective of demonstrating the viability of the aerospike design using additive manufacturing techniques. The aerospike system is a self-compensating design that allows for optimal performance over the entire flight regime and allows for the lowest possible mass vehicle designs. At low altitudes, improvements in Isp can be traded against chamber pressure, staging, and payload. In upper stage applications, expansion ratio and engine envelope can be traded against nozzle efficiency. These features provide flexibility to the System Designer optimizing a complete vehicle stage. The aerospike concept is a good example of a component that has demonstrated improved performance capability, but traditionally has manufacturing requirements that are too expensive and complex to use in a production vehicle. In recent years, additive manufacturing has emerged as a potential method for improving the speed and cost of building geometrically complex components in rocket engines. It offers a reduction in tooling overhead and significant improvements in the integration of the designer and manufacturing method. In addition, the modularity of the engine design provides the ability to perform full scale testing on the combustion devices outside of the full engine configuration. The proposed design uses a hydrocarbon based gas-generator cycle, with plans to take advantage of existing powerhead hardware while focusing DDT&E resources on manufacturing and sub-system testing of the combustion devices. The major risks for the modular aerospike concept lie in the performance of the propellant feed system, the structural integrity of the additive manufactured components, and the aerodynamic efficiency of the exhaust flow.

  4. Risk-based requirements management framework with applications to assurance cases

    NASA Astrophysics Data System (ADS)

    Feng, D.; Eyster, C.

    The current regulatory approach for assuring device safety primarily focuses on compliance with prescriptive safety regulations and relevant safety standards. This approach, however, does not always lead to a safe system design even though safety regulations and standards have been met. In the medical device industry, several high profile recalls involving infusion pumps have prompted the regulatory agency to reconsider how device safety should be managed, reviewed and approved. An assurance case has been cited as a promising tool to address this growing concern. Assurance cases have been used in safety-critical systems for some time. Most assurance cases, if not all, in literature today are developed in an ad hoc fashion, independent from risk management and requirement development. An assurance case is a resource-intensive endeavor that requires additional effort and documentation from equipment manufacturers. Without a well-organized requirements infrastructure in place, such “ additional effort” can be substantial, to the point where the cost of adoption outweighs the benefit of adoption. In this paper, the authors present a Risk-Based Requirements and Assurance Management (RBRAM) methodology. The RBRAM is an elaborate framework that combines Risk-Based Requirements Management (RBRM) with assurance case methods. Such an integrated framework can help manufacturers leverage an existing risk management to present a comprehensive assurance case with minimal additional effort while providing a supplementary means to reexamine the integrity of the system design in terms of the mission objective. Although the example used is from the medical industry, the authors believe that the RBRAM methodology underlines the fundamental principle of risk management, and offers a simple, yet effective framework applicable to aerospace industry, perhaps, to any industry.

  5. Do tanning salons adhere to new legal regulations? Results of a simulated client trial in Germany.

    PubMed

    Möllers, Tobias; Pischke, Claudia R; Zeeb, Hajo

    2016-03-01

    In August 2009 and January 2012, two regulations were passed in Germany to limit UV exposure in the general population. These regulations state that no minors are allowed to use tanning devices. Personnel of tanning salons is mandated to offer counseling regarding individual skin type, to create a dosage plan with the customer and to provide a list describing harmful effects of UV radiation. Furthermore, a poster of warning criteria has to be visible and readable at all times inside the tanning salon. It is unclear whether these regulations are followed by employees of tanning salons in Germany, and we are not aware of any studies examining the implementation of the regulations at individual salons. We performed a simulated client study visiting 20 tanning salons in the city-state of Bremen in the year 2014, using a short checklist of criteria derived from the legal requirements, to evaluate whether legal requirements were followed or not. We found that only 20 % of the tanning salons communicated adverse health effects of UV radiation in visible posters and other materials and that only 60 % of the salons offered the required determination of the skin type to customers. In addition, only 60 % of the salons offered to complete the required dosage plan with their customers. To conclude, our results suggest that the new regulations are insufficiently implemented in Bremen. Additional control mechanisms appear necessary to ensure that consumers are protected from possible carcinogenic effects of excessive UV radiation.

  6. Performance of Single-Use FlexorVue vs Reusable BoaVision Ureteroscope for Visualization of Calices and Stone Extraction in an Artificial Kidney Model.

    PubMed

    Schlager, Daniel; Hein, Simon; Obaid, Moaaz Abdulghani; Wilhelm, Konrad; Miernik, Arkadiusz; Schoenthaler, Martin

    2017-11-01

    To evaluate and compare Flexor ® Vue™, a semidisposable endoscopic deflection system with disposable ureteral sheath and reusable visualization source, and a nondisposable fiber optic ureteroscope in a standard in vitro setting. FlexorVue and a reusable fiber optic flexible ureteroscope were each tested in an artificial kidney model. The experimental setup included the visualization of colored pearls and the extraction of calculi with two different extraction devices (NCircle ® and NGage ® ). The procedures were performed by six experienced surgeons. Visualization time, access to calices, successful stone retraction, and time required were recorded. In addition, the surgeons' workload and subjective performance were determined according to the National Aeronautics and Space Administration-task load index (NASA-TLX). We referred to the Likert scale to assess maneuverability, handling, and image quality. Nearly all calices (99%) were correctly identified using the reusable scope, indicating full kidney access, whereas 74% of the calices were visualized using FlexorVue, of which 81% were correctly identified. Access to the lower poles of the kidney model was significantly less likely with the disposable device, and time to completion was significantly longer (755 s vs 153 s, p < 0.001). The stone clearance success rate with the disposable device was 23% using the NGage and 13% using the NCircle basket. Overall NASA-TLX scores were significantly higher using FlexorVue. The conventional reusable device also demonstrated superior maneuverability, handling, and image quality. FlexorVue offers a semidisposable deflecting endoscopic system allowing basic ureteroscopic and cystoscopic procedures. For its use as an addition or replacement for current reusable scopes, it requires substantial technical improvements.

  7. Energy manager design for microgrids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Firestone, Ryan; Marnay, Chris

    2005-01-01

    On-site energy production, known as distributed energy resources (DER), offers consumers many benefits, such as bill savings and predictability, improved system efficiency, improved reliability, control over power quality, and in many cases, greener electricity. Additionally, DER systems can benefit electric utilities by reducing congestion on the grid, reducing the need for new generation and transmission capacity, and offering ancillary services such as voltage support and emergency demand response. Local aggregations of distributed energy resources (DER) that may include active control of on-site end-use energy devices can be called microgrids. Microgrids require control to ensure safe operation and to make dispatchmore » decisions that achieve system objectives such as cost minimization, reliability, efficiency and emissions requirements, while abiding by system constraints and regulatory rules. This control is performed by an energy manager (EM). Preferably, an EM will achieve operation reasonably close to the attainable optimum, it will do this by means robust to deviations from expected conditions, and it will not itself incur insupportable capital or operation and maintenance costs. Also, microgrids can include supervision over end-uses, such as curtailing or rescheduling certain loads. By viewing a unified microgrid as a system of supply and demand, rather than simply a system of on-site generation devices, the benefits of integrated supply and demand control can be exploited, such as economic savings and improved system energy efficiency.« less

  8. A Solution-Processed Ultrafast Optical Switch Based on a Nanostructured Epsilon-Near-Zero Medium.

    PubMed

    Guo, Qiangbing; Cui, Yudong; Yao, Yunhua; Ye, Yuting; Yang, Yue; Liu, Xueming; Zhang, Shian; Liu, Xiaofeng; Qiu, Jianrong; Hosono, Hideo

    2017-07-01

    All the optical properties of materials are derived from dielectric function. In spectral region where the dielectric permittivity approaches zero, known as epsilon-near-zero (ENZ) region, the propagating light within the material attains a very high phase velocity, and meanwhile the material exhibits strong optical nonlinearity. The interplay between the linear and nonlinear optical response in these materials thus offers unprecedented pathways for all-optical control and device design. Here the authors demonstrate ultrafast all-optical modulation based on a typical ENZ material of indium tin oxide (ITO) nanocrystals (NCs), accessed by a wet-chemistry route. In the ENZ region, the authors find that the optical response in these ITO NCs is associated with a strong nonlinear character, exhibiting sub-picosecond response time (corresponding to frequencies over 2 THz) and modulation depth up to ≈160%. This large optical nonlinearity benefits from the highly confined geometry in addition to the ENZ enhancement effect of the ITO NCs. Based on these ENZ NCs, the authors successfully demonstrate a fiber optical switch that allows switching of continuous laser wave into femtosecond laser pulses. Combined with facile processibility and tunable optical properties, these solution-processed ENZ NCs may offer a scalable and printable material solution for dynamic photonic and optoelectronic devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Beyond activity tracking: next-generation wearable and implantable sensor technologies (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Mercier, Patrick

    2017-05-01

    Current-generation wearable devices have had success continuously measuring the activity and heart rate of subjects during exercise and daily life activities, resulting in interesting new data sets that can, though machine learning algorithms, predict a small subset of health conditions. However, this information is only very peripherally related to most health conditions, and thus offers limited utility to a wide range of the population. In this presentation, I will discuss emerging sensor technologies capable of measuring new and interesting parameters that can potentially offer much more meaningful and actionable data sets. Specifically, I will present recent work on wearable chemical sensors that can, for the first time, continuously monitor a suite of parameters like glucose, alcohol, lactate, and electrolytes, all while wirelessly delivering these results to a smart phone in real time. Demonstration platforms featuring patch, temporary tattoo, and mouthguard form factors will be described, in addition to the corresponding electronics necessary to perform sensor conditioning and wireless readout. Beyond chemical sensors, I will also discuss integration strategies with more conventional electrophysiological and physical parameters like ECG and strain gauges for cardiac and respiration rate monitoring, respectively. Finally, I will conclude the talk by introducing a new form of wireless communications in body-area networks that utilize the body itself as a channel for magnetic energy. Since the power consumption of conventional RF circuits often dominates the power of wearable devices, this new magnetic human body communication technique is specifically architected to dramatically reduce the path loss compared to conventional RF and capacitive human body communication techniques, thereby enabling ultra-low-power body area networks for next-generation wearable devices.

  10. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    PubMed

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  11. A Personal Storm Warning Service

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Although lightning detection systems operated by government agencies, utilities and other businesses provide storm warnings, this information often does not reach the public until some time after the observations have been made. A low-cost personal lightning detector offers a significant safety advantage to private flyers, boaters, golfers and others. Developed by Airborne Research Associates, the detectors originated in Space Shuttle tests of an optical lightning detection technique. The commercial device is pointed toward a cloud to detect invisible intracloud lightning by sensing subtle changes in light presence. The majority of the sales have been to golf courses. Additional products and more advanced applications are in progress.

  12. Challenging the Conventional Wisdom: From Philosophy to Bioethics.

    PubMed

    Miller, Franklin G

    2017-01-01

    Philosophy is a core discipline that has contributed importantly to bioethics. In this essay, the author traces his trajectory from philosophy to bioethics, oriented around the theme of challenging the conventional wisdom. Three topics are discussed to illustrate this theme: the ethics of randomized trials, determination of death and organ transplantation, and pragmatism as a method of bioethics. In addition, the author offers some general reflections on the relationship between philosophy and bioethics. Philosophy recovers itself when it ceases to be a device for dealing with the problems of philosophers and becomes a method, cultivated by philosophers, for dealing with the problems of men.-John Dewey (1917).

  13. Flexible manipulation of terahertz wave reflection using polarization insensitive coding metasurfaces.

    PubMed

    Jiu-Sheng, Li; Ze-Jiang, Zhao; Jian-Quan, Yao

    2017-11-27

    In order to extend to 3-bit encoding, we propose notched-wheel structures as polarization insensitive coding metasurfaces to control terahertz wave reflection and suppress backward scattering. By using a coding sequence of "00110011…" along x-axis direction and 16 × 16 random coding sequence, we investigate the polarization insensitive properties of the coding metasurfaces. By designing the coding sequences of the basic coding elements, the terahertz wave reflection can be flexibly manipulated. Additionally, radar cross section (RCS) reduction in the backward direction is less than -10dB in a wide band. The present approach can offer application for novel terahertz manipulation devices.

  14. Common sense behavior modification: a guide for practitioners.

    PubMed

    Horwitz, Debra F; Pike, Amy L

    2014-05-01

    Behavior problems are often given as a reason for pet relinquishment to shelters. When presented with any behavior problem, veterinarians should perform a thorough physical examination (including neurologic and orthopedic examination) and a minimum database, including a complete blood cell count, chemistry panel, and total T4 and free T4 by equilibrium dialysis if values are low to rule out any medical contributions. Veterinarians should be a source of information regarding management, safety, and basic behavior modification for common behavior problems. Additionally, various control devices offer pet owners the ability to better manage their pets in difficult situations. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Pure-tone Audiometer

    NASA Astrophysics Data System (ADS)

    Kapul, A. A.; Zubova, E. I.; Torgaev, S. N.; Drobchik, V. V.

    2017-08-01

    The research focuses on a pure-tone audiometer designing. The relevance of the study is proved by high incidence of an auditory analyser in older people and children. At first, the article provides information about subjective and objective audiometry methods. Secondly, we offer block-diagram and basic-circuit arrangement of device. We decided to base on STM32F407VG microcontroller and use digital pot in the function of attenuator. Third, we implemented microcontroller and PC connection. C programming language is used for microcontroller’s program and PC’s interface. Fourthly, we created the pure-tone audiometer prototype. In the future, we will implement the objective method ASSR in addition to pure-tone audiometry.

  16. Controlling the Solidification of Organic Photovoltaic Blends with Nucleating Agents

    NASA Astrophysics Data System (ADS)

    Nekuda Malik, Jennifer A.; Treat, Neil D.; Abdelsamie, Maged; Yu, Liyang; Li, Ruipeng; Smilgies, Detlef-M.; Amassian, Aram; Hawker, Craig J.; Chabinyc, Michael L.; Stingelin, Natalie

    2014-11-01

    Blending fullerenes with a donor polymer for the fabrication of organic solar cells often leads to at least partial vitrification of one, if not both, components. For prototypical poly(3-hexylthiophene):fullerene blend, we show that the addition of a commercial nucleating agent, di(3,4-dimethyl benzylidene)sorbitol, to such binary blends accelerates the crystallization of the donor, resulting in an increase in its degree of crystallinity in as-cast structures. This allows manipulation of the extent of intermixing/ phase separation of the donor and acceptor directly from solution, offering a tool to improve device characteristics such as power conversion efficiency.

  17. Connecting Biology to Electronics: Molecular Communication via Redox Modality.

    PubMed

    Liu, Yi; Li, Jinyang; Tschirhart, Tanya; Terrell, Jessica L; Kim, Eunkyoung; Tsao, Chen-Yu; Kelly, Deanna L; Bentley, William E; Payne, Gregory F

    2017-12-01

    Biology and electronics are both expert at for accessing, analyzing, and responding to information. Biology uses ions, small molecules, and macromolecules to receive, analyze, store, and transmit information, whereas electronic devices receive input in the form of electromagnetic radiation, process the information using electrons, and then transmit output as electromagnetic waves. Generating the capabilities to connect biology-electronic modalities offers exciting opportunities to shape the future of biosensors, point-of-care medicine, and wearable/implantable devices. Redox reactions offer unique opportunities for bio-device communication that spans the molecular modalities of biology and electrical modality of devices. Here, an approach to search for redox information through an interactive electrochemical probing that is analogous to sonar is adopted. The capabilities of this approach to access global chemical information as well as information of specific redox-active chemical entities are illustrated using recent examples. An example of the use of synthetic biology to recognize external molecular information, process this information through intracellular signal transduction pathways, and generate output responses that can be detected by electrical modalities is also provided. Finally, exciting results in the use of redox reactions to actuate biology are provided to illustrate that synthetic biology offers the potential to guide biological response through electrical cues. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Handheld Devices: Toward a More Mobile Campus.

    ERIC Educational Resources Information Center

    Fallon, Mary A. C.

    2002-01-01

    Offers an overview of the acceptance and use of handheld personal computing devices on campus that connect wirelessly to the campus network. Considers access; present and future software applications; uses in medial education; faculty training needs; and wireless technology issues. (Author/LRW)

  19. Microelectromechanical Systems and Nephrology: The Next Frontier in Renal Replacement Technology

    PubMed Central

    Kim, Steven; Roy, Shuvo

    2013-01-01

    Microelectromechanical systems (MEMS) is playing a prominent role in the development of many new and innovative biomedical devices, but remains a relatively underutilized technology in nephrology. The future landscape of clinical medicine and research will only see further expansion of MEMS based technologies in device designs and applications. The enthusiasm stems from the ability to create small-scale device features with high precision in a cost effective manner. MEMS also offers the possibility to integrate multiple components into a single device. The adoption of MEMS has the potential to revolutionize how nephrologists manage kidney disease by improving the delivery of renal replacement therapies and enhancing the monitoring of physiologic parameters. To introduce nephrologists to MEMS, this review will first define relevant terms and describe the basic processes used to fabricate MEMS devices. Next, a survey of MEMS devices being developed for various biomedical applications will be illustrated with current examples. Finally, MEMS technology specific to nephrology will be highlighted and future applications will be examined. The adoption of MEMS offers novel avenues to improve the care of kidney disease patients and assist nephrologists in clinical practice. This review will serve as an introduction for nephrologists to the exciting world of MEMS. PMID:24206604

  20. The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases.

    PubMed

    Gelabert-González, M; Ginesta-Galan, V; Sernamito-García, R; Allut, A G; Bandin-Diéguez, J; Rumbo, R M

    2006-04-01

    Intracranial pressure (ICP) monitoring has become standard in the management of neurocritical patients. A variety of monitoring techniques and devices are available, each offering advantages and disadvantages. Analysis of large populations has never been performed. A prospective study was designed to evaluate the Camino fiberoptic intraparenchymal cerebral pressure monitor for complications and accuracy. Between 1992-2004 one thousand consecutive patients had a fiberoptic ICP monitor placed. The most frequent indication for monitoring was severe head injury (697 cases). The average duration of ICP monitoring was 184.6 +/- 94.3 hours; the range was 16-581 hours. Zero drift (range, -17 to 21 mm Hg; mean 7.3 +/- 5.1) was recorded after the devices were removed from 624 patients. Mechanical complications such as: breakage of the optical fiber (n = 17); dislocations of the fixation screw (n = 15) or the probe (n = 13); and failure of ICP recording for unknown reasons (n = 4) were found in 49 Camino devices. The Camino ICP sensor remains one of the most popular ICP monitoring devices for use in critical neurosurgical patients. The system offers reliable ICP measurements in an acceptable percentage of device complications and the advantage of in vivo recalibration. The incidence of technical complications was low and similar to others devices.

  1. Dense Plasma Focus - From Alternative Fusion Source to Versatile High Energy Density Plasma Source for Plasma Nanotechnology

    NASA Astrophysics Data System (ADS)

    Rawat, R. S.

    2015-03-01

    The dense plasma focus (DPF), a coaxial plasma gun, utilizes pulsed high current electrical discharge to heat and compress the plasma to very high density and temperature with energy densities in the range of 1-10 × 1010 J/m3. The DPF device has always been in the company of several alternative magnetic fusion devices as it produces intense fusion neutrons. Several experiments conducted on many different DPF devices ranging over several order of storage energy have demonstrated that at higher storage energy the neutron production does not follow I4 scaling laws and deteriorate significantly raising concern about the device's capability and relevance for fusion energy. On the other hand, the high energy density pinch plasma in DPF device makes it a multiple radiation source of ions, electron, soft and hard x-rays, and neutrons, making it useful for several applications in many different fields such as lithography, radiography, imaging, activation analysis, radioisotopes production etc. Being a source of hot dense plasma, strong shockwave, intense energetic beams and radiation, etc, the DPF device, additionally, shows tremendous potential for applications in plasma nanoscience and plasma nanotechnology. In the present paper, the key features of plasma focus device are critically discussed to understand the novelties and opportunities that this device offers in processing and synthesis of nanophase materials using, both, the top-down and bottom-up approach. The results of recent key experimental investigations performed on (i) the processing and modification of bulk target substrates for phase change, surface reconstruction and nanostructurization, (ii) the nanostructurization of PLD grown magnetic thin films, and (iii) direct synthesis of nanostructured (nanowire, nanosheets and nanoflowers) materials using anode target material ablation, ablated plasma and background reactive gas based synthesis and purely gas phase synthesis of various different types of nanostructured materials using DPF device will discussed to establish this device as versatile tool for plasma nanotechnology.

  2. Spin injection and transport in semiconductor and metal nanostructures

    NASA Astrophysics Data System (ADS)

    Zhu, Lei

    In this thesis we investigate spin injection and transport in semiconductor and metal nanostructures. To overcome the limitation imposed by the low efficiency of spin injection and extraction and strict requirements for retention of spin polarization within the semiconductor, novel device structures with additional logic functionality and optimized device performance have been developed. Weak localization/antilocalization measurements and analysis are used to assess the influence of surface treatments on elastic, inelastic and spin-orbit scatterings during the electron transport within the two-dimensional electron layer at the InAs surface. Furthermore, we have used spin-valve and scanned probe microscopy measurements to investigate the influence of sulfur-based surface treatments and electrically insulating barrier layers on spin injection into, and spin transport within, the two-dimensional electron layer at the surface of p-type InAs. We also demonstrate and analyze a three-terminal, all-electrical spintronic switching device, combining charge current cancellation by appropriate device biasing and ballistic electron transport. The device yields a robust, electrically amplified spin-dependent current signal despite modest efficiency in electrical injection of spin-polarized electrons. Detailed analyses provide insight into the advantages of ballistic, as opposed to diffusive, transport in device operation, as well as scalability to smaller dimensions, and allow us to eliminate the possibility of phenomena unrelated to spin transport contributing to the observed device functionality. The influence of the device geometry on magnetoresistance of nanoscale spin-valve structures is also demonstrated and discussed. Shortcomings of the simplified one-dimensional spin diffusion model for spin valve are elucidated, with comparison of the thickness and the spin diffusion length in the nonmagnetic channel as the criterion for validity of the 1D model. Our work contributes directly to the realization of spin valve and spin transistor devices based on III-V semiconductors, and offers new opportunities to engineer the behavior of spintronic devices at the nanoscale.

  3. Cost-effective rapid prototyping and assembly of poly(methyl methacrylate) microfluidic devices.

    PubMed

    Matellan, Carlos; Del Río Hernández, Armando E

    2018-05-03

    The difficulty in translating conventional microfluidics from laboratory prototypes to commercial products has shifted research efforts towards thermoplastic materials for their higher translational potential and amenability to industrial manufacturing. Here, we present an accessible method to fabricate and assemble polymethyl methacrylate (PMMA) microfluidic devices in a "mask-less" and cost-effective manner that can be applied to manufacture a wide range of designs due to its versatility. Laser micromachining offers high flexibility in channel dimensions and morphology by controlling the laser properties, while our two-step surface treatment based on exposure to acetone vapour and low-temperature annealing enables improvement of the surface quality without deformation of the device. Finally, we demonstrate a capillarity-driven adhesive delivery bonding method that can produce an effective seal between PMMA devices and a variety of substrates, including glass, silicon and LiNbO 3 . We illustrate the potential of this technique with two microfluidic devices, an H-filter and a droplet generator. The technique proposed here offers a low entry barrier for the rapid prototyping of thermoplastic microfluidics, enabling iterative design for laboratories without access to conventional microfabrication equipment.

  4. A "place n play" modular pump for portable microfluidic applications.

    PubMed

    Li, Gang; Luo, Yahui; Chen, Qiang; Liao, Lingying; Zhao, Jianlong

    2012-03-01

    This paper presents an easy-to-use, power-free, and modular pump for portable microfluidic applications. The pump module is a degassed particle desorption polydimethylsiloxane (PDMS) slab with an integrated mesh-shaped chamber, which can be attached on the outlet port of microfluidic device to absorb the air in the microfluidic system and then to create a negative pressure for driving fluid. Different from the existing monolithic degassed PDMS pumps that are generally restricted to limited pumping capacity and are only compatible with PDMS-based microfluidic devices, this pump can offer various possible configures of pumping power by varying the geometries of the pump or by combining different pump modules and can also be employed in any material microfluidic devices. The key advantage of this pump is that its operation only requires the user to place the degassed PDMS slab on the outlet ports of microfluidic devices. To help design pumps with a suitable pumping performance, the effect of pump module geometry on its pumping capacity is also investigated. The results indicate that the performance of the degassed PDMS pump is strongly dependent on the surface area of the pump chamber, the exposure area and the volume of the PDMS pump slab. In addition, the initial volume of air in the closed microfluidic system and the cross-linking degree of PDMS also affect the performance of the degassed PDMS pump. Finally, we demonstrated the utility of this modular pumping method by applying it to a glass-based microfluidic device and a PDMS-based protein crystallization microfluidic device.

  5. A “place n play” modular pump for portable microfluidic applications

    PubMed Central

    Li, Gang; Luo, Yahui; Chen, Qiang; Liao, Lingying; Zhao, Jianlong

    2012-01-01

    This paper presents an easy-to-use, power-free, and modular pump for portable microfluidic applications. The pump module is a degassed particle desorption polydimethylsiloxane (PDMS) slab with an integrated mesh-shaped chamber, which can be attached on the outlet port of microfluidic device to absorb the air in the microfluidic system and then to create a negative pressure for driving fluid. Different from the existing monolithic degassed PDMS pumps that are generally restricted to limited pumping capacity and are only compatible with PDMS-based microfluidic devices, this pump can offer various possible configures of pumping power by varying the geometries of the pump or by combining different pump modules and can also be employed in any material microfluidic devices. The key advantage of this pump is that its operation only requires the user to place the degassed PDMS slab on the outlet ports of microfluidic devices. To help design pumps with a suitable pumping performance, the effect of pump module geometry on its pumping capacity is also investigated. The results indicate that the performance of the degassed PDMS pump is strongly dependent on the surface area of the pump chamber, the exposure area and the volume of the PDMS pump slab. In addition, the initial volume of air in the closed microfluidic system and the cross-linking degree of PDMS also affect the performance of the degassed PDMS pump. Finally, we demonstrated the utility of this modular pumping method by applying it to a glass-based microfluidic device and a PDMS-based protein crystallization microfluidic device. PMID:22685507

  6. Cryotherapy Treatment After Unicompartmental and Total Knee Arthroplasty: A Review.

    PubMed

    Chughtai, Morad; Sodhi, Nipun; Jawad, Michael; Newman, Jared M; Khlopas, Anton; Bhave, Anil; Mont, Michael A

    2017-12-01

    Cryotherapy is widely utilized to enhance recovery after knee surgeries. However, the outcome parameters often vary between studies. Therefore, the purpose of this review is to compare (1) no cryotherapy vs cryotherapy; (2) cold pack cryotherapy vs continuous flow device cryotherapy; (3) various protocols of application of these cryotherapy methods; and (4) cost-benefit analysis in patients who had unicompartmental knee arthroplasty (UKA) or total knee arthroplasty (TKA). A search for "knee" and "cryotherapy" using PubMed, EBSCO Host, and SCOPUS was performed, yielding 187 initial reports. After selecting for RCTs relevant to our study, 16 studies were included. Of the 8 studies that compared the immediate postoperative outcomes between patients who did and did not receive cryotherapy, 5 studies favored cryotherapy (2 cold packs and 3 continuous cold flow devices). Of the 6 studies comparing the use of cold packs and continuous cold flow devices in patients who underwent UKA or TKA, 3 favor the use of continuous flow devices. There was no difference in pain, postoperative opioid consumption, or drain output between 2 different temperature settings of continuous cold flow device. The optimal device to use may be one that offers continuous circulating cold flow, as there were more studies demonstrating better outcomes. In addition, the pain relieving effects of cryotherapy may help minimize pain medication use, such as with opioids, which are associated with numerous potential side effects as well as dependence and addiction. Meta-analysis on the most recent RCTs should be performed next. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Laser microjoining of dissimilar and biocompatible materials

    NASA Astrophysics Data System (ADS)

    Bauer, Ingo; Russek, Ulrich A.; Herfurth, Hans J.; Witte, Reiner; Heinemann, Stefan; Newaz, Golam; Mian, A.; Georgiev, D.; Auner, Gregory W.

    2004-07-01

    Micro-joining and hermetic sealing of dissimilar and biocompatible materials is a critical issue for a broad spectrum of products such as micro-electronics, micro-optical and biomedical products and devices. Today, biocompatible titanium is widely applied as a material for orthopedic implants as well as for the encapsulation of implantable devices such as pacemakers, defibrillators, and neural stimulator devices. Laser joining is the process of choice to hermetically seal such devices. Laser joining is a contact-free process, therefore minimizing mechanical load on the parts to be joined and the controlled heat input decreases the potential for thermal damage to the highly sensitive components. Laser joining also offers flexibility, shorter processing time and higher quality. However, novel biomedical products, in particular implantable microsystems currently under development, pose new challenges to the assembly and packaging process based on the higher level of integration, the small size of the device's features, and the type of materials and material combinations. In addition to metals, devices will also include glass, ceramic and polymers as biocompatible building materials that must be reliably joined in similar and dissimilar combinations. Since adhesives often lack long-term stability or do not meet biocompatibility requirements, new joining techniques are needed to address these joining challenges. Localized laser joining provides promising developments in this area. This paper describes the latest achievements in micro-joining of metallic and non-metallic materials with laser radiation. The focus is on material combinations of metal-polymer, polymer-glass, metal-glass and metal-ceramic using CO2, Nd:YAG and diode laser radiation. The potential for applications in the biomedical sector will be demonstrated.

  8. Physiotherapy and cardiac rhythm devices: a review of the current scope of practice.

    PubMed

    Digby, Geneviève C; Daubney, Marguerite E; Baggs, Jim; Campbell, Debra; Simpson, Christopher S; Redfearn, Damian P; Brennan, F James; Abdollah, Hoshiar; Baranchuk, Adrian

    2009-07-01

    Several case reports have demonstrated negative interactions between various physiotherapy modalities and cardiac rhythm devices (CRD). Fear of these potential interactions may lead to suboptimal utilization of physiotherapy treatments in CRD patients. No prior review of available guidelines, or management strategies, on the interaction between physiotherapy modalities and CRD patients has been reported. To review existing guidelines regarding the use of physiotherapy modalities in patients with pacemakers and/or implantable cardioverter-defibrillators (ICDs). To retrospectively analyse CRD patient encounters at a local physiotherapy facility during a period of 2 years. A review of the literature regarding the potential interactions between physiotherapy modalities and CRDs was performed. Next, a 2 year retrospective analysis of patient encounters at a physiotherapy facility was conducted. In addition, seven international physiotherapy societies and four CRD manufacturers were surveyed with respect to recommendations regarding physiotherapy treatments in device patients. The local physiotherapy facility treated 25 patients with CRD (22 pacemaker and 3 ICD patients) for a total of 230 visits (9.2 visits/patient). Five patients received transcutaneous electrical nerve stimulation (TENS) and all 25 were administered additional treatment in the form of ultrasound (15), acupuncture (19), Laser (7), traction/manual therapy (12), exercise (8), education (18), taping (5), and/or moist heat (5). No complications occurred. Meanwhile, international societies and device manufacturers offered few specific or consistent recommendations. There are no specific international policies regarding the administration of physiotherapy modalities in CRD patients and, thus, there are no specific guidelines to be implemented at the local level. Review of the literature and of recommendations from CRD manufacturers suggests that TENS, Diathermy, and Interferential Electrical Current Therapy are best avoided in patients with CRDs. However, there is no consensus and it may be possible to safely deliver these modalities in a proper setting with device and patient monitoring. Although further research is required in this regard, active collaboration between physiotherapists and CRD clinic physicians should allow for the safe application of most physiotherapy modalities.

  9. An evaluation of strain measuring devices for ceramic composites

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, John Z.; Bartolotta, Paul A.

    1991-01-01

    A series of tensile tests was conducted on SiC/reaction bonded silicon nitrides (RBSN) composites using different methods of strain measurement. The tests were used to find the optimum strain sensing device for use with continuous fiber reinforced ceramic matrix composites in ambient and high temperature environments. Bonded resistance gages were found to offer excellent performance for room temperature tests. The clip-on gage offers the same performance, but less time is required for mounting it to the specimen. Low contact force extensometers track the strain with acceptable results at high specimen temperatures. Silicon carbide rods with knife edges are preferred. The edges must be kept sharp. The strain measuring devices should be mounted on the flat side of the specimen. This is in contrast to mounting on the rough thickness side.

  10. An evaluation of strain measuring devices for ceramic composites

    NASA Technical Reports Server (NTRS)

    Gyekenyesi, John Z.; Bartolotta, Paul A.

    1992-01-01

    A series of tensile tests were conducted on SiC/RBSN composites using different methods of strain measurement. The tests were used to find the optimum strain sensing device for use with continuous fiber reinforced ceramic matrix composites in ambient and high temperature environments. Bonded resistance strain gages were found to offer excellent performance for room temperature tests. The clip-on gage offers the same performance but significantly less time is required for mounting it to the specimen. Low contact force extensometers track the strain with acceptable results at high specimen temperatures. Silicon carbide rods with knife edges are preferred. The edges must be kept sharp. The strain measuring devices should be mounted on the flat side of the specimen. This is in contrast to mounting on the rough thickness side.

  11. Mobile ECMO - A divine technology or bridge to nowhere?

    PubMed

    Merkle, Julia; Djorjevic, Ilija; Sabashnikov, Anton; Kuhn, Elmar W; Deppe, Antje-Christin; Eghbalzadeh, Kaveh; Fattulayev, Javid; Hohmann, Christopher; Zeriouh, Mohamed; Kuhn-Régnier, Ferdinand; Choi, Yeong-Hoon; Mader, Navid; Wahlers, Thorsten

    2017-10-01

    Extracorporeal life support emerged as a salvage option in patients with therapy-refractory severe hemodynamic or respiratory failure. However, this promising therapy option has been limited by the use of experienced teams in highly specialized tertiary-care centers. Thus, in order to provide this standard of care in local hospitals and due to increasing evidence on improved outcomes using ECMO devices and setting for patients with heart and lung failure, an increasing number of experienced ECMO centers have launched mobile ECMO retrieval services in recent years. Areas covered: This review provides a summary on the current scientific status concerning use, indications and complications of mobile ECMO devices and services. A scientific literature research was conducted in MEDLINE, Embase, Cochrane and Web of Science databases using keywords denoted. Expert commentary: Mobile ECMO devices and setting offer severely ill patients refractory to maximal conventional treatment an option of hemodynamic and/or respiratory stabilization and subsequent transportation to specialized care centers for further treatment. Compared to in-hospital ECMO support, out-of-hospital mobile ECMO implantation, transport and retrieval of patients require additional organizational, logistical and clinical efforts. This review provides a summary on the current scientific status concerning use, indications and complications of mobile ECMO services.

  12. Imaging the Root Hair Morphology of Arabidopsis Seedlings in a Two-layer Microfluidic Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aufrecht, Jayde A.; Ryan, Jennifer M.; Hasim, Sahar

    Root hairs increase root surface area for better water uptake and nutrient absorption by the plant. Because they are small in size and often obscured by their natural environment, root hair morphology and function are difficult to study and often excluded from plant research. In recent years, microfluidic platforms have offered a way to visualize root systems at high resolution without disturbing the roots during transfer to an imaging system. The microfluidic platform presented here builds on previous plant-on-a-chip research by incorporating a two-layer device to confine the Arabidopsis thaliana main root to the same optical plane as the rootmore » hairs. This design enables the quantification of root hairs on a cellular and organelle level and also prevents z-axis drifting during the addition of experimental treatments. We describe how to store the devices in a contained and hydrated environment, without the need for fluidic pumps, while maintaining a gnotobiotic environment for the seedling. After the optical imaging experiment, the device may be disassembled and used as a substrate for atomic force or scanning electron microscopy while keeping fine root structures intact.« less

  13. Imaging the Root Hair Morphology of Arabidopsis Seedlings in a Two-layer Microfluidic Platform

    DOE PAGES

    Aufrecht, Jayde A.; Ryan, Jennifer M.; Hasim, Sahar; ...

    2017-08-01

    Root hairs increase root surface area for better water uptake and nutrient absorption by the plant. Because they are small in size and often obscured by their natural environment, root hair morphology and function are difficult to study and often excluded from plant research. In recent years, microfluidic platforms have offered a way to visualize root systems at high resolution without disturbing the roots during transfer to an imaging system. The microfluidic platform presented here builds on previous plant-on-a-chip research by incorporating a two-layer device to confine the Arabidopsis thaliana main root to the same optical plane as the rootmore » hairs. This design enables the quantification of root hairs on a cellular and organelle level and also prevents z-axis drifting during the addition of experimental treatments. We describe how to store the devices in a contained and hydrated environment, without the need for fluidic pumps, while maintaining a gnotobiotic environment for the seedling. After the optical imaging experiment, the device may be disassembled and used as a substrate for atomic force or scanning electron microscopy while keeping fine root structures intact.« less

  14. Implantable centrifugal blood pump with dual impeller and double pivot bearing system: electromechanical actuator, prototyping, and anatomical studies.

    PubMed

    Bock, Eduardo; Antunes, Pedro; Leao, Tarcisio; Uebelhart, Beatriz; Fonseca, Jeison; Leme, Juliana; Utiyama, Bruno; da Silva, Cibele; Cavalheiro, Andre; Filho, Diolino Santos; Dinkhuysen, Jarbas; Biscegli, Jose; Andrade, Aron; Arruda, Celso

    2011-05-01

    An implantable centrifugal blood pump has been developed with original features for a left ventricular assist device. This pump is part of a multicenter and international study with the objective to offer simple, affordable, and reliable devices to developing countries. Previous computational fluid dynamics investigations and wear evaluation in bearing system were performed followed by prototyping and in vitro tests. In addition, previous blood tests for assessment of normalized index of hemolysis show results of 0.0054±2.46 × 10⁻³ mg/100 L. An electromechanical actuator was tested in order to define the best motor topology and controller configuration. Three different topologies of brushless direct current motor (BLDCM) were analyzed. An electronic driver was tested in different situations, and the BLDCM had its mechanical properties tested in a dynamometer. Prior to evaluation of performance during in vivo animal studies, anatomical studies were necessary to achieve the best configuration and cannulation for left ventricular assistance. The results were considered satisfactory, and the next step is to test the performance of the device in vivo. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. Microfluidic Devices for Drug Delivery Systems and Drug Screening

    PubMed Central

    Kompella, Uday B.; Damiati, Safa A.

    2018-01-01

    Microfluidic devices present unique advantages for the development of efficient drug carrier particles, cell-free protein synthesis systems, and rapid techniques for direct drug screening. Compared to bulk methods, by efficiently controlling the geometries of the fabricated chip and the flow rates of multiphase fluids, microfluidic technology enables the generation of highly stable, uniform, monodispersed particles with higher encapsulation efficiency. Since the existing preclinical models are inefficient drug screens for predicting clinical outcomes, microfluidic platforms might offer a more rapid and cost-effective alternative. Compared to 2D cell culture systems and in vivo animal models, microfluidic 3D platforms mimic the in vivo cell systems in a simple, inexpensive manner, which allows high throughput and multiplexed drug screening at the cell, organ, and whole-body levels. In this review, the generation of appropriate drug or gene carriers including different particle types using different configurations of microfluidic devices is highlighted. Additionally, this paper discusses the emergence of fabricated microfluidic cell-free protein synthesis systems for potential use at point of care as well as cell-, organ-, and human-on-a-chip models as smart, sensitive, and reproducible platforms, allowing the investigation of the effects of drugs under conditions imitating the biological system. PMID:29462948

  16. A single pixel camera video ophthalmoscope

    NASA Astrophysics Data System (ADS)

    Lochocki, B.; Gambin, A.; Manzanera, S.; Irles, E.; Tajahuerce, E.; Lancis, J.; Artal, P.

    2017-02-01

    There are several ophthalmic devices to image the retina, from fundus cameras capable to image the whole fundus to scanning ophthalmoscopes with photoreceptor resolution. Unfortunately, these devices are prone to a variety of ocular conditions like defocus and media opacities, which usually degrade the quality of the image. Here, we demonstrate a novel approach to image the retina in real-time using a single pixel camera, which has the potential to circumvent those optical restrictions. The imaging procedure is as follows: a set of spatially coded patterns is projected rapidly onto the retina using a digital micro mirror device. At the same time, the inner product's intensity is measured for each pattern with a photomultiplier module. Subsequently, an image of the retina is reconstructed computationally. Obtained image resolution is up to 128 x 128 px with a varying real-time video framerate up to 11 fps. Experimental results obtained in an artificial eye confirm the tolerance against defocus compared to a conventional multi-pixel array based system. Furthermore, the use of a multiplexed illumination offers a SNR improvement leading to a lower illumination of the eye and hence an increase in patient's comfort. In addition, the proposed system could enable imaging in wavelength ranges where cameras are not available.

  17. Photocurrent enhancement of graphene photodetectors by photon tunneling of light into surface plasmons

    NASA Astrophysics Data System (ADS)

    Maleki, Alireza; Cumming, Benjamin P.; Gu, Min; Downes, James E.; Coutts, David W.; Dawes, Judith M.

    2017-10-01

    We demonstrate that surface plasmon resonances excited by photon tunneling through an adjacent dielectric medium enhance the photocurrent detected by a graphene photodetector. The device is created by overlaying a graphene sheet over an etched gap in a gold film deposited on glass. The detected photocurrents are compared for five different excitation wavelengths, ranging from {λ }0=570 {{nm}} to {λ }0=730 {{nm}}. Although the device is not optimized, the photocurrent excited with incident p-polarized light (which excites resonant surface plasmons) is significantly amplified in comparison with that for s-polarized light (without surface plasmon resonances). We observe that the photocurrent is greater for shorter wavelengths (for both s- and p-polarizations) with increased photothermal current. Position-dependent Raman spectroscopic analysis of the optically-excited graphene photodetector indicates the presence of charge carriers in the graphene near the metallic edge. In addition, we show that the polarity of the photocurrent reverses across the gap as the incident light spot moves across the gap. Graphene-based photodetectors offer a simple architecture which can be fabricated on dielectric waveguides to exploit the plasmonic photocurrent enhancement of the evanescent field. Applications for these devices include photodetection, optical sensing and direct plasmonic detection.

  18. Integrated Optical Mach-Zehnder Interferometer Based on Organic-Inorganic Hybrids for Photonics-on-a-Chip Biosensing Applications.

    PubMed

    Bastos, Ana R; Vicente, Carlos M S; Oliveira-Silva, Rui; Silva, Nuno J O; Tacão, Marta; Costa, João P da; Lima, Mário; André, Paulo S; Ferreira, Rute A S

    2018-03-12

    The development of portable low-cost integrated optics-based biosensors for photonics-on-a-chip devices for real-time diagnosis are of great interest, offering significant advantages over current analytical methods. We report the fabrication and characterization of an optical sensor based on a Mach-Zehnder interferometer to monitor the growing concentration of bacteria in a liquid medium. The device pattern was imprinted on transparent self-patternable organic-inorganic di-ureasil hybrid films by direct UV-laser, reducing the complexity and cost production compared with lithographic techniques or three-dimensional (3D) patterning using femtosecond lasers. The sensor performance was evaluated using, as an illustrative example, E. coli cell growth in an aqueous medium. The measured sensitivity (2 × 10 -4 RIU) and limit of detection (LOD = 2 × 10 -4 ) are among the best values known for low-refractive index contrast sensors. Furthermore, the di-ureasil hybrid used to produce this biosensor has additional advantages, such as mechanical flexibility, thermal stability, and low insertion losses due to fiber-device refractive index mismatch (~1.49). Therefore, the proposed sensor constitutes a direct, compact, fast, and cost-effective solution for monitoring the concentration of lived-cells.

  19. Uncooled infrared photodetectors in Poland

    NASA Astrophysics Data System (ADS)

    Piotrowski, Jozef; Piotrowski, Adam

    2005-09-01

    The history and present status of the middle and long wavelength Hg1xCdxTe infrared detectors in Poland are reviewed. Research and development efforts in Poland were concentrated mostly on uncooled market niche. Technology of the infrared photodetectors has been developed by several research groups. The devices are based on mercury-based variable band gap semiconductor alloys. Modified isothermal vapor phase epitaxy (ISOVPE) has been used for many years for research and commercial fabrication of photoconductive, photoelectromagnetic and other devices. Bulk growth and liquid phase epitaxy was also used. At present, the fabrication of IR devices relies on low temperature epitaxial technique, namely metalorganic vapor phase deposition (MOCVD), frequently in combination with the ISOVPE. Photoconductive and photoelectromagnetic detectors are still in production. The devices are gradually replaced with photovoltaic devices which offer inherent advantages of no electric or magnetic bias, no heat load and no flicker noise. Potentially, the PV devices could offer high performance and very fast response. Actually, the uncooled long wavelength devices of conventional design suffer from two issues; namely low quantum efficiency and very low junction resistance. It makes them useless for practical applications. The problems have been solved with advanced 3D band gap engineered architecture, multiple cell heterojunction devices connected in series, monolithic integration of the detectors with microoptics and other improvements. Present fabrication program includes devices which are optimized for operation at any wavelength within a wide spectral range 1-15 μm and 200-300 K temperature range. Special solutions have been applied to improve speed of response. Some devices show picoseconds range response time. The devices have found numerous civilian and military applications.

  20. Self-Resetting Energy Absorber

    NASA Technical Reports Server (NTRS)

    De La Fuente, Horacio M.; Nagy, Kornel; Wesselski, Clarence J.

    1992-01-01

    Device uses friction to dissipate kinetic energy. When moving mass pushes in one direction, it offers substantial friction. Pushed in opposite direction, it offers negligible friction. Built-in spring resets for another shock-absorption cycle. Used in industrial machinery, automobile bumpers and suspensions, and parachute lanyards.

  1. Properties of piezoresistive silicon nano-scale cantilevers with applications to BioNEMS

    NASA Astrophysics Data System (ADS)

    Arlett, Jessica Lynn

    Over the last decade a great deal of interest has been raised in applications of Microelectromechanical Sensors [MEMS] for the detection of biological molecules and to the study of their forces of interaction. Experiments in these areas have included Force Spectroscopy (Chemical Force Microscopy), MEMS patch clamp technology, and surface stress sensors. All of these technologies suffer from limitations on temporal response and involve devices with active surface areas that are large compared to molecular dimensions. Biofunctionalized nanoelectromechanical systems (BioNEMS) have the potential to overcome both of these hurdles, offering important new prospects for single-molecule force assays that are amenable to large scale integration. Results are presented here on the characterization of piezoresistive silicon cantilevers with applications to BioNEMS devices. The cantilevers were characterized by studying their response in gaseous ambients under a number of drive conditions including magnetic, piezoelectric, and thermal actuation, in addition to passive detection of the thermomechanical response. The measurements were performed at liquid helium temperature, at room temperature, and over a range of pressures (atmospheric pressure to 30mT). Theoretical studies have been performed on the response of these devices to Brownian fluctuations in fluid, on the feasibility of these devices as surface stress sensors, and on improvements in device design as compared to piezoresistive surface stress sensors currently discussed in the literature. The devices were encapsulated in microfluidics and measurements were performed to show the noise floor in fluid. The piezoresistive response of the device in fluid was shown through the use of pulsatory fluidic drive. As a proof of concept, biodetection experiments are presented for biotin labeled beads. The biofunctionalization for the latter experiment was performed entirely within the microfluidics. A discussion of how these experiments can be extended to other cells, spores, and molecules is presented.

  2. NLL-Assisted Multilayer Graphene Patterning

    PubMed Central

    2018-01-01

    The range of applications of diverse graphene-based devices could be limited by insufficient surface reactivity, unsatisfied shaping, or null energy gap of graphene. Engineering the graphene structure by laser techniques can adjust the transport properties and the surface area of graphene, providing devices of different nature with a higher capacitance. Additionally, the created periodic potential and appearance of the active external/inner/edge surface centers determine the multifunctionality of the graphene surface and corresponding devices. Here, we report on the first implementation of nonlinear laser lithography (NLL) for multilayer graphene (MLG) structuring, which offers a low-cost, single-step, and high-speed nanofabrication process. The NLL relies on the employment of a high repetition rate femtosecond Yb fiber laser that provides generation of highly reproducible, robust, uniform, and periodic nanostructures over a large surface area (1 cm2/15 s). NLL allows one to obtain clearly predesigned patterned graphene structures without fabrication tolerances, which are caused by contacting mask contamination, polymer residuals, and direct laser exposure of the graphene layers. We represent regularly patterned MLG (p-MLG) obtained by the chemical vapor deposition method on an NLL-structured Ni foil. We also demonstrate tuning of chemical (wettability) and electro-optical (transmittance and sheet resistance) properties of p-MLG by laser power adjustments. In conclusion, we show the great promise of fabricated devices, namely, supercapacitors, and Li-ion batteries by using NLL-assisted graphene patterning. Our approach demonstrates a new avenue to pattern graphene for multifunctional device engineering in optics, photonics, and bioelectronics. PMID:29503971

  3. NLL-Assisted Multilayer Graphene Patterning.

    PubMed

    Kovalska, Evgeniya; Pavlov, Ihor; Deminskyi, Petro; Baldycheva, Anna; Ilday, F Ömer; Kocabas, Coskun

    2018-02-28

    The range of applications of diverse graphene-based devices could be limited by insufficient surface reactivity, unsatisfied shaping, or null energy gap of graphene. Engineering the graphene structure by laser techniques can adjust the transport properties and the surface area of graphene, providing devices of different nature with a higher capacitance. Additionally, the created periodic potential and appearance of the active external/inner/edge surface centers determine the multifunctionality of the graphene surface and corresponding devices. Here, we report on the first implementation of nonlinear laser lithography (NLL) for multilayer graphene (MLG) structuring, which offers a low-cost, single-step, and high-speed nanofabrication process. The NLL relies on the employment of a high repetition rate femtosecond Yb fiber laser that provides generation of highly reproducible, robust, uniform, and periodic nanostructures over a large surface area (1 cm 2 /15 s). NLL allows one to obtain clearly predesigned patterned graphene structures without fabrication tolerances, which are caused by contacting mask contamination, polymer residuals, and direct laser exposure of the graphene layers. We represent regularly patterned MLG (p-MLG) obtained by the chemical vapor deposition method on an NLL-structured Ni foil. We also demonstrate tuning of chemical (wettability) and electro-optical (transmittance and sheet resistance) properties of p-MLG by laser power adjustments. In conclusion, we show the great promise of fabricated devices, namely, supercapacitors, and Li-ion batteries by using NLL-assisted graphene patterning. Our approach demonstrates a new avenue to pattern graphene for multifunctional device engineering in optics, photonics, and bioelectronics.

  4. The "Skull Flap" a new conceived device for decompressive craniectomy experimental study on dogs to evaluate the safety and efficacy in reducing intracranial pressure and subsequent impact on brain perfusion.

    PubMed

    Salvatore, Chibbaro; Fabrice, Vallee; Marco, Marsella; Leonardo, Tigan; Thomas, Lilin; Benoit, Lecuelle; Bernard, George; Pierre, Kehrli; Eric, Vicaut; Paolo, Diemidio

    2013-10-01

    Decompressive craniectomy (DC) is a procedure performed increasingly often in current neurosurgical practice. Significant perioperative morbidity may be associated to this procedure because of the large skull defect; also, later closure of the skull defect (cranioplasty) may be associated to post-operative morbidity as much as any other reconstructive operation. The authors present a newly conceived/developed device: The "Skull Flap" (SF). This system, placed at the time of the craniectomy, offers the possibility to provide cranial reconstruction sparing patients a second operation. In other words, DC and cranioplasty essentially take place at the same time and in addition, patients retain their own bone flap. The current study conducted on animal models, represents the logical continuation of a prior recent study, realized on cadaver specimens, to assess the efficacy and safety of this recently developed device. This is an experimental pilot study on dogs to assess both safety and efficacy of the SF device. Two groups of experimental raised intracranial pressure animal models underwent DC; in the first group of dogs, the bone flap was left in raised position above the skull defect using the SF device; on the second group the flap was discarded. All dogs underwent transcranial Doppler (TCD) to assess brain perfusion. Head computed tomography (CT) scan to determine flap position was also obtained in the group in which the SF device was placed. SF has proved to be a strong fixation device that allows satisfactory brain decompression by keeping the bone flap elevated from the swollen brain; later on, the SF allows cranial reconstruction in a simple way without requiring a second staged operation. In addition, it is relevant to note that brain perfusion was measured and found to be better in the group receiving the SF (while the flap being in a raised as well as in its natural position) comparing to the other group. The SF device has proved to be very easy to place, well-adaptable to a different type of flaps and ultimately very effective in maintaining satisfactory brain decompression and later on, making easy bone flap repositioning after brain swelling has subsided.

  5. Applied Cognitive Models of Behavior and Errors Patterns

    DTIC Science & Technology

    2017-09-01

    methods offer an opportunity to deliver good , effective introductory and basic training , thus potentially enabling a single human instructor to train ...emergency medical technician (EMT) domain, which offers a standardized curriculum on which we can create training scenarios. 2. Develop...complexity of software integration and limited access to physical devices can result in commitment to a de- sign that turns out to not offer many training

  6. Unidirectional spin Hall magnetoresistance in topological insulator/ferromagnetic layer heterostructures

    NASA Astrophysics Data System (ADS)

    Kally, James; Lv, Yang; Zhang, Delin; Lee, Joon Sue; Samarth, Nitin; Wang, Jian-Ping; Department of Electrical; Computer Engineering, University of Minnesota, Minneapolis Collaboration; Department of Physics, Pennsylvania State University Collaboration

    The surface states of topological insulators offer a potentially very efficient way to generate spins and spin-orbit torques to magnetic moments in proximity. The switching by spin-orbit torque itself only requires two terminals so that a charge current can be applied. However, a third terminal with additional magnetic tunneling junction structure is needed to sense the magnetization state if such devices are used for memory and logic applications. The recent discovery of unidirectional spin Hall magnetoresistance in heavy metal/ferromagnetic and topological insulator/magnetically doped topological insulator systems offers an alternative way to sense magnetization while still keeping the number of terminals to minimal two. The unidirectional spin Hall magnetoresistance in topological insulator/strong ferromagnetic layer heterostructure system has yet not been reported. In this work, we report our experimental observations of such magnetoresistance. It is found to be present and comparable to the best result of the previous reported Ta/Co systems in terms of magnetoresistance per current density per total resistance.

  7. Voltage Scaling of Graphene Device on SrTiO3 Epitaxial Thin Film.

    PubMed

    Park, Jeongmin; Kang, Haeyong; Kang, Kyeong Tae; Yun, Yoojoo; Lee, Young Hee; Choi, Woo Seok; Suh, Dongseok

    2016-03-09

    Electrical transport in monolayer graphene on SrTiO3 (STO) thin film is examined in order to promote gate-voltage scaling using a high-k dielectric material. The atomically flat surface of thin STO layer epitaxially grown on Nb-doped STO single-crystal substrate offers good adhesion between the high-k film and graphene, resulting in nonhysteretic conductance as a function of gate voltage at all temperatures down to 2 K. The two-terminal conductance quantization under magnetic fields corresponding to quantum Hall states survives up to 200 K at a magnetic field of 14 T. In addition, the substantial shift of charge neutrality point in graphene seems to correlate with the temperature-dependent dielectric constant of the STO thin film, and its effective dielectric properties could be deduced from the universality of quantum phenomena in graphene. Our experimental data prove that the operating voltage reduction can be successfully realized due to the underlying high-k STO thin film, without any noticeable degradation of graphene device performance.

  8. Label-free in-flow detection of single DNA molecules using glass nanopipettes.

    PubMed

    Gong, Xiuqing; Patil, Amol V; Ivanov, Aleksandar P; Kong, Qingyuan; Gibb, Thomas; Dogan, Fatma; deMello, Andrew J; Edel, Joshua B

    2014-01-07

    With the view of enhancing the functionality of label-free single molecule nanopore-based detection, we have designed and developed a highly robust, mechanically stable, integrated nanopipette-microfluidic device which combines the recognized advantages of microfluidic systems and the unique properties/advantages of nanopipettes. Unlike more typical planar solid-state nanopores, which have inherent geometrical constraints, nanopipettes can be easily positioned at any point within a microfluidic channel. This is highly advantageous, especially when taking into account fluid flow properties. We show that we are able to detect and discriminate between DNA molecules of varying lengths when motivated through a microfluidic channel, upon the application of appropriate voltage bias across the nanopipette. The effects of applied voltage and volumetric flow rates have been studied to ascertain translocation event frequency and capture rate. Additionally, by exploiting the advantages associated with microfluidic systems (such as flow control and concomitant control over analyte concentration/presence), we show that the technology offers a new opportunity for single molecule detection and recognition in microfluidic devices.

  9. Approaching soft X-ray wavelengths in nanomagnet-based microwave technology

    PubMed Central

    Yu, Haiming; d' Allivy Kelly, O.; Cros, V.; Bernard, R.; Bortolotti, P.; Anane, A.; Brandl, F.; Heimbach, F.; Grundler, D.

    2016-01-01

    Seven decades after the discovery of collective spin excitations in microwave-irradiated ferromagnets, there has been a rebirth of magnonics. However, magnetic nanodevices will enable smart GHz-to-THz devices at low power consumption only, if such spin waves (magnons) are generated and manipulated on the sub-100 nm scale. Here we show how magnons with a wavelength of a few 10 nm are exploited by combining the functionality of insulating yttrium iron garnet and nanodisks from different ferromagnets. We demonstrate magnonic devices at wavelengths of 88 nm written/read by conventional coplanar waveguides. Our microwave-to-magnon transducers are reconfigurable and thereby provide additional functionalities. The results pave the way for a multi-functional GHz technology with unprecedented miniaturization exploiting nanoscale wavelengths that are otherwise relevant for soft X-rays. Nanomagnonics integrated with broadband microwave circuitry offer applications that are wide ranging, from nanoscale microwave components to nonlinear data processing, image reconstruction and wave-based logic. PMID:27063401

  10. Nanocomposites Based on Thermoplastic Polymers and Functional Nanofiller for Sensor Applications

    PubMed Central

    Coiai, Serena; Passaglia, Elisa; Pucci, Andrea; Ruggeri, Giacomo

    2015-01-01

    Thermoplastic polymers like polyolefins, polyesters, polyamide, and styrene polymers are the most representative commodity plastics thanks to their cost-efficient manufacturing processes, excellent thermomechanical properties and their good environmental compatibility, including easy recycling. In the last few decades much effort has been devoted worldwide to extend the applications of such materials by conferring on them new properties through mixing and blending with different additives. In this latter context, nanocomposites have recently offered new exciting possibilities. This review discusses the successful use of nanostructured dispersed substrates in designing new stimuli-responsive nanocomposites; in particular, it provides an updated description of the synthetic routes to prepare nanostructured systems having the typical properties of thermoplastic polymers (continuous matrix), but showing enhanced optical, conductive, and thermal features dependent on the dispersion topology. The controlled nanodispersion of functional labeled clays, noble metal nanoparticles and carbon nanotubes is here evidenced to play a key role in producing hybrid thermoplastic materials that have been used in the design of devices, such as NLO devices, chemiresistors, temperature and deformation sensors.

  11. Robotic single-access splenectomy using the Da Vinci Single-Site® platform: a case report.

    PubMed

    Corcione, Francesco; Bracale, Umberto; Pirozzi, Felice; Cuccurullo, Diego; Angelini, Pier Luigi

    2014-03-01

    Single-access laparoscopic splenectomy can offer patients some advantages. It has many difficulties, such as instrument clashing, lack of triangulation, odd angles and lack of space. The Da Vinci Single-Site® robotic surgery platform could decrease these difficulties. We present a case of single-access robotic splenectomy using this device. A 37 year-old female with idiopathic thrombocytopenic purpura was operated on with a single-site approach, using the Da Vinci Single-Site robotic surgery device. The procedure was successfully completed in 140 min. No intraoperative and postoperative complications occurred. The patient was discharged from hospital on day 3. Single-access robotic splenectomy seems to be feasible and safe using the new robotic single-access platform, which seems to overcome certain limits of previous robotic or conventional single-access laparoscopy. We think that additional studies should also be performed to explore the real cost-effectiveness of the platform. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Non-Equilibrium Plasma Processing for the Preparation of Antibacterial Surfaces

    PubMed Central

    Sardella, Eloisa; Palumbo, Fabio; Camporeale, Giuseppe; Favia, Pietro

    2016-01-01

    Non-equilibrium plasmas offer several strategies for developing antibacterial surfaces that are able to repel and/or to kill bacteria. Due to the variety of devices, implants, and materials in general, as well as of bacteria and applications, plasma assisted antibacterial strategies need to be tailored to each specific surface. Nano-composite coatings containing inorganic (metals and metal oxides) or organic (drugs and biomolecules) compounds can be deposited in one step, and used as drug delivery systems. On the other hand, functional coatings can be plasma-deposited and used to bind antibacterial molecules, for synthesizing surfaces with long lasting antibacterial activity. In addition, non-fouling coatings can be produced to inhibit the adhesion of bacteria and reduce the formation of biofilm. This paper reviews plasma-based strategies aimed to reduce bacterial attachment and proliferation on biomedical materials and devices, but also onto materials used in other fields. Most of the activities described have been developed in the lab of the authors. PMID:28773637

  13. Comparison of different patient positioning strategies to minimize shoulder girdle artifacts in head and neck CT.

    PubMed

    Wirth, Stefan; Meindl, Thomas; Treitl, Marcus; Pfeifer, Klaus-Jürgen; Reiser, Maximilian

    2006-08-01

    The purpose of this study was to analyze different patient positioning strategies for minimizing artifacts of the shoulder girdle in head and neck CT. Standardized CT examinations of three positioning groups were compared (P: patients pushed their shoulders downwards; D: similar optimization by a pulling device; N: no particular positioning optimization). Parameters analyzed were the length of the cervical spine not being superimposed by the shoulder girdle as well as noise in the supraclavicular space. In groups P and D, the portion of the cervical spine not superimposed was significantly larger than in group N (P: 10.4 cm; D: 10.6 cm; N: 8.5 cm). At the supraclavicular space, noise decreased significantly (P: 12.5 HU; D: 12.1 HU; N: 17.7 HU). No significant differences between the two position-optimized groups (P and D) were detected. Optimized shoulder positioning by the patient increases image quality in CT head and neck imaging. The use of a pulling device offers no additional advantages.

  14. Solar cells using quantum funnels.

    PubMed

    Kramer, Illan J; Levina, Larissa; Debnath, Ratan; Zhitomirsky, David; Sargent, Edward H

    2011-09-14

    Colloidal quantum dots offer broad tuning of semiconductor bandstructure via the quantum size effect. Devices involving a sequence of layers comprised of quantum dots selected to have different diameters, and therefore bandgaps, offer the possibility of funneling energy toward an acceptor. Here we report a quantum funnel that efficiently conveys photoelectrons from their point of generation toward an intended electron acceptor. Using this concept we build a solar cell that benefits from enhanced fill factor as a result of this quantum funnel. This concept addresses limitations on transport in soft condensed matter systems and leverages their advantages in large-area optoelectronic devices and systems.

  15. Home automation in the workplace.

    PubMed

    McCormack, J E; Tello, S F

    1994-01-01

    Environmental control units and home automation devices contribute to the independence and potential of individuals with disabilities, both at work and at home. Devices currently exist that can assist people with physical, cognitive, and sensory disabilities to control lighting, appliances, temperature, security, and telephone communications. This article highlights several possible applications for these technologies and discusses emerging technologies that will increase the benefits these devices offer people with disabilities.

  16. Challenges and climate of business environment and resources to support pediatric device development.

    PubMed

    Iqbal, Corey W; Wall, James; Harrison, Michael R

    2015-06-01

    The incidence of pediatric disease conditions pales in comparison to adult disease. Consequently, many pediatric disorders are considered orphan diseases. Resources for the development of devices targeting orphan diseases are scarce and this poses a unique challenge to the development of pediatric devices. This article outlines these challenges and offers solutions. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Ab Initio Assessment of the Thermoelectric Performance of Ruthenium-Doped Gadolinium Orthotantalate

    NASA Technical Reports Server (NTRS)

    Goldsby, Jon

    2016-01-01

    Solid state energy harvesting using waste heat available in gas turbine engine, offers potential for power generation to meet growing power needs of aircraft. Thermoelectric material advances offer new opportunities. Weight-optimized integrated turbine engine structure incorporating energy conversion devices.

  18. Robotics Literacy Captivates Elementary Students.

    ERIC Educational Resources Information Center

    Friedman, Madeleine

    1986-01-01

    Describes a robotics literacy course offered for elementary age children at Broward Community College (Florida) and discusses the motivation for offering such a course, the course philosophy and objectives, and participant reactions. A sampling of robots and robotics devices and some of their teaching applications are included. (MBR)

  19. Output Devices, Computation, and the Future of Mathematical Crafts.

    ERIC Educational Resources Information Center

    Eisenberg, Michael

    2002-01-01

    The advent of powerful, affordable output devices offers the potential for a vastly expanded landscape of computationally-enriched mathematical craft activities in education. Craft activities have both intellectual and emotional affordances that are relatively lacking in "traditional" computer-based education. Describes three software applications…

  20. Storage Reliability of Missile Materiel Program. Storage Reliability Analysis Summary Report. Volume 1. Electrical and Electronic Devices

    DTIC Science & Technology

    1978-01-01

    silicon nitride seals the devices from sodium and since the platinum silicide and titanium metals also offer very low mobility to the alkaline ions, the...of bipolar devices. These materials act as gettering agents for sodium ions, thus making the contamination far less mobile. The stability of the...parameter instability. Silicon nitride has been shown to be an effective barrier to sodium migration. In Beam Lead Sealed Junction (BLSJ) devices, the

  1. Long-period fiber phase grating devices

    NASA Astrophysics Data System (ADS)

    Stegall, David Brian

    In recent years, the explosive growth of the internet has virtually surpassed the limits of the global communications infrastructure. As a result, the fiber- optic communications industry is spearheading research and development to transmit information at ever increasing rates and over longer distances. The industry faces several obstacles to improving the performance of these systems. One problem is dispersion, which manifests at faster transmission rates when pulse spreading and distortion scramble the signal. Furthermore, high transmission powers needed for longer distances introduce deleterious optical nonlinearity phenomenon. Several waveguide and bulk devices have been implemented to address these issues, but each have shortcomings. Many of these problems and challenges have also impacted other fiber-optic industries, such as sensor systems. Long- period optical fiber gratings pose simple solutions to these problems and offer novel applications previously impractical through any other means. In this dissertation, research is presented in which modeling and fabrication of long-period gratings is improved over existing techniques by incorporating the effects of waveguide dispersion. An arbitrary dispersion also can be introduced into a long-period grating intentionally and a theoretical examination is made relating the chirp of a long-period grating and the resulting dispersion. In addition, several device applications such as a biological sensor and the concept of an actively controlled transmission spectrum of a long-period grating are explored. Finally, multiple in-series Bragg and long- period gratings are investigated for novel device configurations.

  2. Unsupervised heart-rate estimation in wearables with Liquid states and a probabilistic readout.

    PubMed

    Das, Anup; Pradhapan, Paruthi; Groenendaal, Willemijn; Adiraju, Prathyusha; Rajan, Raj Thilak; Catthoor, Francky; Schaafsma, Siebren; Krichmar, Jeffrey L; Dutt, Nikil; Van Hoof, Chris

    2018-03-01

    Heart-rate estimation is a fundamental feature of modern wearable devices. In this paper we propose a machine learning technique to estimate heart-rate from electrocardiogram (ECG) data collected using wearable devices. The novelty of our approach lies in (1) encoding spatio-temporal properties of ECG signals directly into spike train and using this to excite recurrently connected spiking neurons in a Liquid State Machine computation model; (2) a novel learning algorithm; and (3) an intelligently designed unsupervised readout based on Fuzzy c-Means clustering of spike responses from a subset of neurons (Liquid states), selected using particle swarm optimization. Our approach differs from existing works by learning directly from ECG signals (allowing personalization), without requiring costly data annotations. Additionally, our approach can be easily implemented on state-of-the-art spiking-based neuromorphic systems, offering high accuracy, yet significantly low energy footprint, leading to an extended battery-life of wearable devices. We validated our approach with CARLsim, a GPU accelerated spiking neural network simulator modeling Izhikevich spiking neurons with Spike Timing Dependent Plasticity (STDP) and homeostatic scaling. A range of subjects is considered from in-house clinical trials and public ECG databases. Results show high accuracy and low energy footprint in heart-rate estimation across subjects with and without cardiac irregularities, signifying the strong potential of this approach to be integrated in future wearable devices. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Skill Games for Mathematics.

    ERIC Educational Resources Information Center

    Corle, Clyde G.

    This guide is to assist teachers with motivational ideas for teaching elementary school mathematics. The items included are a wide variety of games (paper and pencil, verbal, and physical), jingles, contests, teaching devices, and thought provoking exercises. Suggestions for selection of mathematical games are offered. The devices are used to…

  4. Counterfeit esthetic devices and patient safety in dermatology.

    PubMed

    Wang, Jordan V; Zachary, Christopher B; Saedi, Nazanin

    2018-06-01

    This study addresses the dilemma concerned with meeting patients who may have encountered counterfeit esthetic devices in the marketplace. Over the past several years, we have witnessed a rise in counterfeit injectables and medical devices in our field. Often times, the procedures are marketed to patients at significantly reduced prices compared to competitors. Patients may be unaware that counterfeit devices exist and may unknowingly have procedures completed using untested and uncertified devices. It is important for clinicians to recognize when their patients may be encountering counterfeit devices, know what to do in this situation, and offer the best recommendations. © 2018 Wiley Periodicals, Inc.

  5. Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones.

    PubMed

    Yang, Ke; Peretz-Soroka, Hagit; Liu, Yong; Lin, Francis

    2016-03-21

    Portable electronic devices and wireless communication systems enable a broad range of applications such as environmental and food safety monitoring, personalized medicine and healthcare management. Particularly, hybrid smartphone and microfluidic devices provide an integrated solution for the new generation of mobile sensing applications. Such mobile sensing based on microfluidic devices (broadly defined) and smartphones (MS(2)) offers a mobile laboratory for performing a wide range of bio-chemical detection and analysis functions such as water and food quality analysis, routine health tests and disease diagnosis. MS(2) offers significant advantages over traditional platforms in terms of test speed and control, low cost, mobility, ease-of-operation and data management. These improvements put MS(2) in a promising position in the fields of interdisciplinary basic and applied research. In particular, MS(2) enables applications to remote in-field testing, homecare, and healthcare in low-resource areas. The marriage of smartphones and microfluidic devices offers a powerful on-chip operating platform to enable various bio-chemical tests, remote sensing, data analysis and management in a mobile fashion. The implications of such integration are beyond telecommunication and microfluidic-related research and technology development. In this review, we will first provide the general background of microfluidic-based sensing, smartphone-based sensing, and their integration. Then, we will focus on several key application areas of MS(2) by systematically reviewing the important literature in each area. We will conclude by discussing our perspectives on the opportunities, issues and future directions of this emerging novel field.

  6. Novel Developments of Mobile Sensing Based on the Integration of Microfluidic Devices and Smartphone

    PubMed Central

    Yang, Ke; Peretz-Soroka, Hagit; Liu, Yong; Lin, Francis

    2016-01-01

    Portable electronic devices and wireless communication systems enable a broad range of applications such as environmental and food safety monitoring, personalized medicine and healthcare management. Particularly, hybrid smartphone and microfluidic devices provide an integrated solution for the new generation of mobile sensing applications. Such mobile sensing based on microfluidic devices (broadly defined) and smartphones (MS2) offers a mobile laboratory for performing a wide range of bio-chemical detection and analysis functions such as water and food quality analysis, routine health tests and disease diagnosis. MS2 offers significant advantages over traditional platforms in terms of test speed and control, low cost, mobility, ease-of-operation and data management. These improvements put MS2 in a promising position in the fields of interdisciplinary basic and applied research. In particular, MS2 enables applications to remote infield testing, homecare, and healthcare in low-resource areas. The marriage of smartphones and microfluidic devices offers a powerful on-chip operating platform to enable various bio-chemical tests, remote sensing, data analysis and management in a mobile fashion. The implications of such integration are beyond telecommunication and microfluidic-related research and technology development. In this review, we will first provide the general background of microfluidic-based sensing, smartphone-based sensing, and their integration. Then, we will focus on several key application areas of MS2 by systematically reviewing the important literature in each area. We will conclude by discussing our perspectives on the opportunities, issues and future directions of this emerging novel field. PMID:26899264

  7. Uncooled infrared photodetectors in Poland

    NASA Astrophysics Data System (ADS)

    Piotrowski, J.; Piotrowski, A.

    2006-03-01

    The history and present status of the middle and long wavelength Hg1-xCdxTe infrared detectors in Poland are reviewed. Research and development efforts in Poland were concentrated mostly on uncooled market niche. Technology of the infrared photodetectors has been developed by several research groups. The devices are based on mercury-based variable band gap semiconductor alloys. Modified isothermal vapour phase epitaxy (ISOVPE) has been used for many years for research and commercial fabrication of photoconductive, photoelectromagnetic and other devices. Bulk growth and liquid phase epitaxy was also used. At present, the fabrication of IR devices relies on low temperature epitaxial technique, namely metalorganic vapour phase deposition (MOCVD), frequently in combination with the ISOVPE. Photoconductive and photoelectromagnetic detectors are still in production. The devices are gradually replaced with photovoltaic devices which offer inherent advantages of no electric or magnetic bias, no heat load and no flicker noise. Potentially, the PV devices could offer high performance and very fast response. At present, the uncooled long wavelength devices of conventional design suffer from two issues; namely low quantum efficiency and very low junction resistance. It makes them useless for practical applications. The problems have been solved with advanced 3D band gap engineered architecture, multiple cell heterojunction devices connected in series, monolithic integration of the detectors with microoptics and other improvements. Present fabrication program includes devices which are optimized for operation at any wavelength within a wide spectral range 1-15 μm and 200-300 K temperature range. Special solutions have been applied to improve speed of response. Some devices show picoseconds range response time. The devices have found numerous civilian and military applications.

  8. Are new supraglottic airway devices, tracheal tubes and airway viewing devices cost-effective?

    PubMed

    Slinn, Simon J; Froom, Stephen R; Stacey, Mark R W; Gildersleve, Christopher D

    2015-01-01

    Over the past two decades, a plethora of new airway devices has become available to the pediatric anesthetist. While all have the laudable intention of improving patient care and some have proven clinical benefits, these devices are often costly and at times claims of an advantage over current equipment and techniques are marginal. Supraglottic airway devices are used in the majority of pediatric anesthetics delivered in the U.K., and airway-viewing devices provide an alternative for routine intubation as well as an option in the management of the difficult airway. Yet hidden beneath the convenience of the former and the technology of the latter, the impact on basic airway skills with a facemask and the lack of opportunities to fine-tune the core skill of intubation represent an unrecognised and unquantifiable cost. A judgement on this value must be factored into the absolute purchase cost and any potential benefits to the quality of patient care, thus blurring any judgement on cost-effectiveness that we might have. An overall value on cost-effectiveness though not in strict monetary terms can then be ascribed. In this review, we evaluate the role of these devices in the care of the pediatric patient and attempt to balance the advantages they offer against the cost they incur, both financial and environmental, and in any quality improvement they might offer in clinical care. © 2014 John Wiley & Sons Ltd.

  9. Solar paint: From synthesis to printing

    DOE PAGES

    Zhou, Xiaojing; Belcher, Warwick; Dastoor, Paul

    2014-11-13

    Water-based polymer nanoparticle dispersions (solar paint) offer the prospect of addressing two of the main challenges associated with printing large area organic photovoltaic devices; namely, how to control the nanoscale architecture of the active layer and eliminate the need for hazardous organic solvents during device fabrication. We review progress in the field of nanoparticulate organic photovoltaic (NPOPV) devices and future prospects for large-scale manufacturing of solar cells based on this technology.

  10. "I Just bought my residents iPads… now what?" The integration of mobile devices into radiology resident education.

    PubMed

    Bedi, Harprit S; Yucel, Edgar K

    2013-10-01

    This article describes how mobile technologies can improve the way we teach radiology and offers ideas to bridge the clinical gap with technology. Radiology programs across the country are purchasing iPads and other mobile devices for their residents. Many programs, however, do not have a concrete vision for how a mobile device can enhance the learning environment.

  11. Solar paint: From synthesis to printing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Xiaojing; Belcher, Warwick; Dastoor, Paul

    Water-based polymer nanoparticle dispersions (solar paint) offer the prospect of addressing two of the main challenges associated with printing large area organic photovoltaic devices; namely, how to control the nanoscale architecture of the active layer and eliminate the need for hazardous organic solvents during device fabrication. We review progress in the field of nanoparticulate organic photovoltaic (NPOPV) devices and future prospects for large-scale manufacturing of solar cells based on this technology.

  12. Silicon Processors Using Organically Reconfigurable Techniques (SPORT)

    DTIC Science & Technology

    2014-05-19

    towards producing SWPC devices. ATR measurements on these thin films reveal a 30% increase in the EO activity of the OEOM films after thermal ...poling and recover about 50% the EO activity of thermally -poled films without poling. A simple proof-of-concept device architecture was fabricated and...device in peer-reviewed literature. New organic EO host materials developed at UD for the SPORT program offer increased thermal stability and EO

  13. Blood Pump Development Using Rocket Engine Flow Simulation Technology

    NASA Technical Reports Server (NTRS)

    Kiris, Cetin C.; Kwak, Dochan

    2002-01-01

    This viewgraph presentation provides information on the transfer of rocket engine flow simulation technology to work involving the development of blood pumps. Details are offered regarding the design and requirements of mechanical heart assist devices, or VADs (ventricular assist device). There are various computational fluid dynamics issues involved in the visualization of flow in such devices, and these are highlighted and compared to those of rocket turbopumps.

  14. MBE HgCdTe for HDVIP Devices: Horizontal Integration in the US HgCdTe FPA Industry

    NASA Astrophysics Data System (ADS)

    Aqariden, F.; Elsworth, J.; Zhao, J.; Grein, C. H.; Sivananthan, S.

    2012-10-01

    Molecular beam epitaxy (MBE) growth of HgCdTe offers the possibility of fabricating multilayer device structures with an almost unlimited choice of infrared sensor designs for focal-plane array (FPA) fabrication. HgCdTe offers two major advantages that explain its dominance in the infrared photon detector marketplace. The thermal generation rate per unit volume of the material is lower and the quantum efficiency for photon absorption in the infrared is higher in HgCdTe than in any competing material—it yields devices with quantum efficiencies as high as 0.99. Recently, EPIR Technologies and DRS Infrared Technologies agreed to collaborate and examine: (i) the feasibility of employing MBE HgCdTe in the fabrication of high-density vertically interconnected photodiodes (HDVIPs), which are usually fabricated with liquid-phase epitaxy material, and (ii) the potential benefits of horizontal integration, with EPIR supplying the MBE materials to DRS for device and array fabrication. The team designed and developed passivation-absorber-passivation structures that are heavily used by DRS. This paper provides an overview of the characteristics of HDVIP devices and arrays fabricated from MBE HgCdTe and the anticipated advantages of horizontal integration in the industry. Material growth, device fabrication, and test results are presented.

  15. Organic n-type materials for charge transport and charge storage applications.

    PubMed

    Stolar, Monika; Baumgartner, Thomas

    2013-06-21

    Conjugated materials have attracted much attention toward applications in organic electronics in recent years. These organic species offer many advantages as potential replacement for conventional materials (i.e., silicon and metals) in terms of cheap fabrication and environmentally benign devices. While p-type (electron-donating or hole-conducting) materials have been extensively reviewed and researched, their counterpart n-type (electron-accepting or electron-conducting) materials have seen much less popularity despite the greater need for improvement. In addition to developing efficient charge transport materials, it is equally important to provide a means of charge storage, where energy can be used on an on-demand basis. This perspective is focused on discussing a selection of representative n-type materials and the efforts toward improving their charge-transport efficiencies. Additionally, this perspective will also highlight recent organic materials for battery components and the efforts that have been made to improve their environmental appeal.

  16. 76 FR 82353 - Implementing the Provisions of the Communications Act of 1934, as Enacted by the Twenty-First...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-30

    ..., equipment or services must be compatible with existing peripheral devices or specialized customer premises... offer advanced communications services in or affecting interstate commerce, including resellers and...) the extent to which the service provider or manufacturer in question offers accessible services or...

  17. Preservice Teachers' Experiences on Accessing Course Materials Using Mobile Devices

    ERIC Educational Resources Information Center

    Unal, Zafer; Unal, Aslihan

    2014-01-01

    This study investigates and reports the first time experiences of mobile device users accessing the course materials on both the web and mobile version of course management system (Web Moodle & Mobile Moodle) during an online course offered at the University of South Florida, St. Petersburg College of Education.

  18. Enhancing Field Research Methods with Mobile Survey Technology

    ERIC Educational Resources Information Center

    Glass, Michael R.

    2015-01-01

    This paper assesses the experience of undergraduate students using mobile devices and a commercial application, iSurvey, to conduct a neighborhood survey. Mobile devices offer benefits for enhancing student learning and engagement. This field exercise created the opportunity for classroom discussions on the practicalities of urban research, the…

  19. 77 FR 38769 - 97th Annual Meeting of the National Conference on Weights and Measures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ... testing equipment that comprise the regulatory control of commercial weighing and measuring devices. The... specifications to recognize current marketing practices of offering pre or post delivery discounts on fuel prices... proposal would allow device manufacturers greater flexibility in the design and operation of customer...

  20. Digital Movement Analysis in Physical Education

    ERIC Educational Resources Information Center

    Trout, Josh

    2013-01-01

    Mobile devices such as smartphones and tablets offer applications (apps) that make digital movement analysis simple and efficient in physical education. Highly sophisticated movement analysis software has been available for many years but has mainly appealed to coaches of elite athletes and biomechanists. Apps on mobile devices are less expensive…

  1. Optical encryption and QR codes: secure and noise-free information retrieval.

    PubMed

    Barrera, John Fredy; Mira, Alejandro; Torroba, Roberto

    2013-03-11

    We introduce for the first time the concept of an information "container" before a standard optical encrypting procedure. The "container" selected is a QR code which offers the main advantage of being tolerant to pollutant speckle noise. Besides, the QR code can be read by smartphones, a massively used device. Additionally, QR code includes another secure step to the encrypting benefits the optical methods provide. The QR is generated by means of worldwide free available software. The concept development probes that speckle noise polluting the outcomes of normal optical encrypting procedures can be avoided, then making more attractive the adoption of these techniques. Actual smartphone collected results are shown to validate our proposal.

  2. Intelligent Optical Systems Using Adaptive Optics

    NASA Technical Reports Server (NTRS)

    Clark, Natalie

    2012-01-01

    Until recently, the phrase adaptive optics generally conjured images of large deformable mirrors being integrated into telescopes to compensate for atmospheric turbulence. However, the development of smaller, cheaper devices has sparked interest for other aerospace and commercial applications. Variable focal length lenses, liquid crystal spatial light modulators, tunable filters, phase compensators, polarization compensation, and deformable mirrors are becoming increasingly useful for other imaging applications including guidance navigation and control (GNC), coronagraphs, foveated imaging, situational awareness, autonomous rendezvous and docking, non-mechanical zoom, phase diversity, and enhanced multi-spectral imaging. The active components presented here allow flexibility in the optical design, increasing performance. In addition, the intelligent optical systems presented offer advantages in size and weight and radiation tolerance.

  3. Skyrmion-based multi-channel racetrack

    NASA Astrophysics Data System (ADS)

    Song, Chengkun; Jin, Chendong; Wang, Jinshuai; Xia, Haiyan; Wang, Jianbo; Liu, Qingfang

    2017-11-01

    Magnetic skyrmions are promising for the application of racetrack memories, logic gates, and other nano-devices, owing to their topologically protected stability, small size, and low driving current. In this work, we propose a skyrmion-based multi-channel racetrack memory where the skyrmion moves in the selected channel by applying voltage-controlled magnetic anisotropy gates. It is demonstrated numerically that a current-dependent skyrmion Hall effect can be restrained by the additional potential of the voltage-controlled region, and the skyrmion velocity and moving channel in the racetrack can be operated by tuning the voltage-controlled magnetic anisotropy, gate position, and current density. Our results offer a potential application of racetrack memory based on skyrmions.

  4. Charge balancing in GaN-based 2-D electron gas devices employing an additional 2-D hole gas and its influence on dynamic behaviour of GaN-based heterostructure field effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahn, Herwig, E-mail: hahn@gan.rwth-aachen.de; Reuters, Benjamin; Geipel, Sascha

    2015-03-14

    GaN-based heterostructure FETs (HFETs) featuring a 2-D electron gas (2DEG) can offer very attractive device performance for power-switching applications. This performance can be assessed by evaluation of the dynamic on-resistance R{sub on,dyn} vs. the breakdown voltage V{sub bd}. In literature, it has been shown that with a high V{sub bd}, R{sub on,dyn} is deteriorated. The impairment of R{sub on,dyn} is mainly driven by electron injection into surface, barrier, and buffer traps. Electron injection itself depends on the electric field which typically peaks at the gate edge towards the drain. A concept suitable to circumvent this issue is the charge-balancing conceptmore » which employs a 2-D hole gas (2DHG) on top of the 2DEG allowing for the electric field peak to be suppressed. Furthermore, the 2DEG concentration in the active channel cannot decrease by a change of the surface potential. Hence, beside an improvement in breakdown voltage, also an improvement in dynamic behaviour can be expected. Whereas the first aspect has already been demonstrated, the second one has not been under investigation so far. Hence, in this report, the effect of charge-balancing is discussed and its impact on the dynamic characteristics of HFETs is evaluated. It will be shown that with appropriate device design, the dynamic behaviour of HFETs can be improved by inserting an additional 2DHG.« less

  5. Single-port access laparoscopic reversal of Hartmann operation.

    PubMed

    Borowski, D W; Kanakala, V; Agarwal, A K; Tabaqchali, M A; Garg, D K; Gill, T S

    2011-08-01

    Single-port access offers cosmetic advantages in addition to the well-recognized benefits of standard multiport laparoscopic surgery, and can be performed with the use of standard straight instruments. We describe a technique of single-port access reversal of Hartmann colostomy by use of the colostomy site for access. After routine skin preparation and laparoscopic setup, the colostomy is mobilized from its mucocutaneous border, and the anvil of a circular stapler is secured to the distal lumen. By the use of a GelPoint system with 3 or 4 trocars, the intra-abdominal adhesions are divided and the splenic flexure is mobilized to achieve sufficient access to the abdominal and pelvic cavities and proximal colonic mobility. The rectal stump is mobilized to the mid rectum, starting from the posterior mesorectal fascia around to the anterior rectal wall. A tension-free colorectal anastomosis is secured with a standard circular stapling device inserted transanally, and leak tested. The colostomy wound is closed in standard fashion. Five patients underwent single-port access reversal of Hartmann resection (4 diverticular perforations and 1 pT3N0 colon cancer), with a mean operating time of 155 (range, 137-187) minutes and a median length of stay of 3 (range, 2-11) days. There were no conversions, major surgical morbidity, or deaths. Single-port access reversal of Hartmann colostomy through the stoma site is safe, and it offers additional cosmetic advantages with no apparent additional morbidity in comparison with standard multiport surgery.

  6. Global vision system in laparoscopy.

    PubMed

    Rivas-Blanco, I; Sánchez-de-Badajoz, E; García-Morales, I; Lage-Sánchez, J M; Sánchez-Gallegos, P; Pérez-Del-Pulgar, C J; Muñoz, V F

    2017-05-01

    The main difficulty in laparoscopic or robot-assisted surgery is the narrow visual field, restricted by the endoscope's access port. This restriction is coupled with the difficulty of handling the instruments, which is due not only to the access port but also to the loss of depth of field and perspective due to the lack of natural lighting. In this article, we describe a global vision system and report on our initial experience in a porcine model. The global vision system consists of a series of intraabdominal devices, which increase the visual field and help recover perspective through the simulation of natural shadows. These devices are a series of high-definition cameras and LED lights, which are inserted and fixed to the wall using magnets. The system's efficacy was assessed in a varicocelectomy and nephrectomy. The various intraabdominal cameras offer a greater number of intuitive points of view of the surgical field compared with the conventional telescope and appear to provide a similar view as that in open surgery. Areas previously inaccessible to the standard telescope can now be reached. The additional light sources create shadows that increase the perspective of the surgical field. This system appears to increase the possibilities for laparoscopic or robot-assisted surgery because it offers an instant view of almost the entire abdomen, enabling more complex procedures, which currently require an open pathway. Copyright © 2016 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Numerical Modeling of Pulse Detonation Rocket Engine Gasdynamics and Performance

    NASA Technical Reports Server (NTRS)

    Morris, C. I.

    2003-01-01

    Pulse detonation engines (PDB) have generated considerable research interest in recent years as a chemical propulsion system potentially offering improved performance and reduced complexity compared to conventional gas turbines and rocket engines. The detonative mode of combustion employed by these devices offers a theoretical thermodynamic advantage over the constant-pressure deflagrative combustion mode used in conventional engines. However, the unsteady blowdown process intrinsic to all pulse detonation devices has made realistic estimates of the actual propulsive performance of PDES problematic. The recent review article by Kailasanath highlights some of the progress that has been made in comparing the available experimental measurements with analytical and numerical models.

  8. Metallo-supramolecular modules as a paradigm for materials science

    PubMed Central

    Kurth, Dirk G.

    2008-01-01

    Metal ion coordination in discrete or extended metallo-supramolecular assemblies offers ample opportunity to fabricate and study devices and materials that are equally important for fundamental research and new technologies. Metal ions embedded in a specific ligand field offer diverse thermodynamic, kinetic, chemical, physical and structural properties that make these systems promising candidates for active components in functional materials. A key challenge is to improve and develop methodologies for placing these active modules in suitable device architectures, such as thin films or mesophases. This review highlights recent developments in extended, polymeric metallo-supramolecular systems and discrete polyoxometalates with an emphasis on materials science. PMID:27877929

  9. Medical Robotic and Tele surgical Simulation Education Research

    DTIC Science & Technology

    2017-05-01

    training exercises, DVSS = 40, dVT = 65, and RoSS = 52 for skills development. All three offer 3D visual images but use different display technologies...capabilities with an emphasis on their educational skills. They offer unique advantages and capabilities in training robotic sur- geons. Each device has been...evaluate the transfer of training effect of each simulator. Collectively, this work will offer end users and potential buyers a comparison of the value

  10. Electronics for Extreme Environments

    NASA Astrophysics Data System (ADS)

    Patel, J. U.; Cressler, J.; Li, Y.; Niu, G.

    2001-01-01

    Most of the NASA missions involve extreme environments comprising radiation and low or high temperatures. Current practice of providing friendly ambient operating environment to electronics costs considerable power and mass (for shielding). Immediate missions such as the Europa orbiter and lander and Mars landers require the electronics to perform reliably in extreme conditions during the most critical part of the mission. Some other missions planned in the future also involve substantial surface activity in terms of measurements, sample collection, penetration through ice and crust and the analysis of samples. Thus it is extremely critical to develop electronics that could reliably operate under extreme space environments. Silicon On Insulator (SOI) technology is an extremely attractive candidate for NASA's future low power and high speed electronic systems because it offers increased transconductance, decreased sub-threshold slope, reduced short channel effects, elimination of kink effect, enhanced low field mobility, and immunity from radiation induced latch-up. A common belief that semiconductor devices function better at low temperatures is generally true for bulk devices but it does not hold true for deep sub-micron SOI CMOS devices with microscopic device features of 0.25 micrometers and smaller. Various temperature sensitive device parameters and device characteristics have recently been reported in the literature. Behavior of state of the art technology devices under such conditions needs to be evaluated in order to determine possible modifications in the device design for better performance and survivability under extreme environments. Here, we present a unique approach of developing electronics for extreme environments to benefit future NASA missions as described above. This will also benefit other long transit/life time missions such as the solar sail and planetary outposts in which electronics is out open in the unshielded space at the ambient space temperatures and always exposed to radiation. Additional information is contained in the original extended abstract.

  11. Using SDI-12 with ST microelectronics MCU's

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saari, Alexandra; Hinzey, Shawn Adrian; Frigo, Janette Rose

    2015-09-03

    ST Microelectronics microcontrollers and processors are readily available, capable and economical processors. Unfortunately they lack a broad user base like similar offerings from Texas Instrument, Atmel, or Microchip. All of these devices could be useful in economical devices for remote sensing applications used with environmental sensing. With the increased need for environmental studies, and limited budgets, flexibility in hardware is very important. To that end, and in an effort to increase open support of ST devices, I am sharing my teams' experience in interfacing a common environmental sensor communication protocol (SDI-12) with ST devices.

  12. Monolithic device for modelocking and stabilization of frequency combs.

    PubMed

    Lee, C-C; Hayashi, Y; Silverman, K L; Feldman, A; Harvey, T; Mirin, R P; Schibli, T R

    2015-12-28

    We demonstrate a device that integrates a III-V semiconductor saturable absorber mirror with a graphene electro-optic modulator, which provides a monolithic solution to modelocking and noise suppression in a frequency comb. The device offers a pure loss modulation bandwidth exceeding 5 MHz and only requires a low voltage driver. This hybrid device provides not only compactness and simplicity in laser cavity design, but also small insertion loss, compared to the previous metallic-mirror-based modulators. We believe this work paves the way to portable and fieldable phase-coherent frequency combs.

  13. Three-Dimensional Printing Based Hybrid Manufacturing of Microfluidic Devices.

    PubMed

    Alapan, Yunus; Hasan, Muhammad Noman; Shen, Richang; Gurkan, Umut A

    2015-05-01

    Microfluidic platforms offer revolutionary and practical solutions to challenging problems in biology and medicine. Even though traditional micro/nanofabrication technologies expedited the emergence of the microfluidics field, recent advances in advanced additive manufacturing hold significant potential for single-step, stand-alone microfluidic device fabrication. One such technology, which holds a significant promise for next generation microsystem fabrication is three-dimensional (3D) printing. Presently, building 3D printed stand-alone microfluidic devices with fully embedded microchannels for applications in biology and medicine has the following challenges: (i) limitations in achievable design complexity, (ii) need for a wider variety of transparent materials, (iii) limited z-resolution, (iv) absence of extremely smooth surface finish, and (v) limitations in precision fabrication of hollow and void sections with extremely high surface area to volume ratio. We developed a new way to fabricate stand-alone microfluidic devices with integrated manifolds and embedded microchannels by utilizing a 3D printing and laser micromachined lamination based hybrid manufacturing approach. In this new fabrication method, we exploit the minimized fabrication steps enabled by 3D printing, and reduced assembly complexities facilitated by laser micromachined lamination method. The new hybrid fabrication method enables key features for advanced microfluidic system architecture: (i) increased design complexity in 3D, (ii) improved control over microflow behavior in all three directions and in multiple layers, (iii) transverse multilayer flow and precisely integrated flow distribution, and (iv) enhanced transparency for high resolution imaging and analysis. Hybrid manufacturing approaches hold great potential in advancing microfluidic device fabrication in terms of standardization, fast production, and user-independent manufacturing.

  14. Design and Development of a Miniaturized Percutaneously Deployable Wireless Left Ventricular Assist Device: Early Prototypes and Feasibility Testing.

    PubMed

    Letzen, Brian; Park, Jiheum; Tuzun, Zeynep; Bonde, Pramod

    The current left ventricular assist devices (LVADs) are limited by a highly invasive implantation procedure in a severely unstable group of advanced heart failure patients. Additionally, the current transcutaneous power drive line acts as a nidus for infection resulting in significant morbidity and mortality. In an effort to decrease this invasiveness and eliminate drive line complications, we have conceived a wireless miniaturized percutaneous LVAD, capable of being delivered endovascularly with a tether-free operation. The system obviates the need for a transcutaneous fluid purge line required in existing temporary devices by utilizing an incorporated magnetically coupled impeller for a complete seal. The objective of this article was to demonstrate early development and proof-of-concept feasibility testing to serve as the groundwork for future formalized device development. Five early prototypes were designed and constructed to iteratively minimize the pump size and improve fluid dynamic performance. Various magnetic coupling configurations were tested. Using SolidWorks and ANSYS software for modeling and simulation, several geometric parameters were varied. HQ curves were constructed from preliminary in vitro testing to characterize the pump performance. Bench top tests showed no-slip magnetic coupling of the impeller to the driveshaft up to the current limit of the motor. The pump power requirements were tested in vitro and were within the appropriate range for powering via a wireless energy transfer system. Our results demonstrate the proof-of-concept feasibility of a novel endovascular cardiac assist device with the potential to eventually offer patients an untethered, minimally invasive support.

  15. Development of a high permeability cored transintegumental power transformer.

    PubMed

    Helmicki, A J; Melvin, D M; Henderson, H T; Nebrigic, D; Venkat, R; Glos, D L

    1996-01-01

    Circulatory support devices require 10-20 W. Currently, several devices are under development for the transmission of this power via transcutaneous transformers, with the secondary implanted subcutaneously and the primary worn externally. Because these devices are air cored, they have relatively large, bulky external appliances, poor coil to coil coupling, and result in significant stray fields passing through adjacent tissues. This article reports on the engineering design of a novel, high permeability cored transformer implanted in a transenteric configuration using an isolated intestinal pouch. Such an approach offers greater energy transmission efficiency, less heat dissipation, less stray electromagnetic energy, and greatly reduced device size. Two competing designs using this concept have been developed and tested. Each consists of the transformer, together with power interface electronics, forming a direct current (DC)/DC resonant converter. Operating frequencies are 90.2 and 14.7 kHz, respectively, with primary/secondary turns ratios of 10/10 and 11/14, respectively. In addition, data interface electronics allows communication across the transformer of up to four signals at a per channel sample rate of 10 Hz. Both designs are able to continuously transmit 25 W at an output level of 12 Vdc into a 5.8 omega load. Calorimetry tests indicate DC to DC efficiencies greater than 75% and coil to coil efficiencies greater than 96%. Total package size for the implantable portion of each device (including sensor internal interface electronics) is less than 40 ml, with a weight weight of less than 100 g. The results of short-term implantation studies have been favorable. Long-term implantation studies currently are under way.

  16. Three-Dimensional Printing Based Hybrid Manufacturing of Microfluidic Devices

    PubMed Central

    Shen, Richang; Gurkan, Umut A.

    2016-01-01

    Microfluidic platforms offer revolutionary and practical solutions to challenging problems in biology and medicine. Even though traditional micro/nanofabrication technologies expedited the emergence of the microfluidics field, recent advances in advanced additive manufacturing hold significant potential for single-step, stand-alone microfluidic device fabrication. One such technology, which holds a significant promise for next generation microsystem fabrication is three-dimensional (3D) printing. Presently, building 3D printed stand-alone microfluidic devices with fully embedded microchannels for applications in biology and medicine has the following challenges: (i) limitations in achievable design complexity, (ii) need for a wider variety of transparent materials, (iii) limited z-resolution, (iv) absence of extremely smooth surface finish, and (v) limitations in precision fabrication of hollow and void sections with extremely high surface area to volume ratio. We developed a new way to fabricate stand-alone microfluidic devices with integrated manifolds and embedded microchannels by utilizing a 3D printing and laser micromachined lamination based hybrid manufacturing approach. In this new fabrication method, we exploit the minimized fabrication steps enabled by 3D printing, and reduced assembly complexities facilitated by laser micromachined lamination method. The new hybrid fabrication method enables key features for advanced microfluidic system architecture: (i) increased design complexity in 3D, (ii) improved control over microflow behavior in all three directions and in multiple layers, (iii) transverse multilayer flow and precisely integrated flow distribution, and (iv) enhanced transparency for high resolution imaging and analysis. Hybrid manufacturing approaches hold great potential in advancing microfluidic device fabrication in terms of standardization, fast production, and user-independent manufacturing. PMID:27512530

  17. Inorganic photovoltaic devices fabricated using nanocrystal spray deposition.

    PubMed

    Foos, Edward E; Yoon, Woojun; Lumb, Matthew P; Tischler, Joseph G; Townsend, Troy K

    2013-09-25

    Soluble inorganic nanocrystals offer a potential route to the fabrication of all-inorganic devices using solution deposition techniques. Spray processing offers several advantages over the more common spin- and dip-coating procedures, including reduced material loss during fabrication, higher sample throughput, and deposition over a larger area. The primary difference observed, however, is an overall increase in the film roughness. In an attempt to quantify the impact of this morphology change on the devices, we compare the overall performance of spray-deposited versus spin-coated CdTe-based Schottky junction solar cells and model their dark current-voltage characteristics. Spray deposition of the active layer results in a power conversion efficiency of 2.3 ± 0.3% with a fill factor of 45.7 ± 3.4%, Voc of 0.39 ± 0.06 V, and Jsc of 13.3 ± 3.0 mA/cm(2) under one sun illumination.

  18. High performance photovoltaic applications using solution-processed small molecules.

    PubMed

    Chen, Yongsheng; Wan, Xiangjian; Long, Guankui

    2013-11-19

    Energy remains a critical issue for the survival and prosperity of humancivilization. Many experts believe that the eventual solution for sustainable energy is the use of direct solar energy as the main energy source. Among the options for renewable energy, photovoltaic technologies that harness solar energy offer a way to harness an unlimited resource and minimum environment impact in contrast with other alternatives such as water, nuclear, and wind energy. Currently, almost all commercial photovoltaic technologies use Si-based technology, which has a number of disadvantages including high cost, lack of flexibility, and the serious environmental impact of the Si industry. Other technologies, such as organic photovoltaic (OPV) cells, can overcome some of these issues. Today, polymer-based OPV (P-OPV) devices have achieved power conversion efficiencies (PCEs) that exceed 9%. Compared with P-OPV, small molecules based OPV (SM-OPV) offers further advantages, including a defined structure for more reproducible performance, higher mobility and open circuit voltage, and easier synthetic control that leads to more diversified structures. Therefore, while largely undeveloped, SM-OPV is an important emerging technology with performance comparable to P-OPV. In this Account, we summarize our recent results on solution-processed SM-OPV. We believe that solution processing is essential for taking full advantage of OPV technologies. Our work started with the synthesis of oligothiophene derivatives with an acceptor-donor-acceptor (A-D-A) structure. Both the backbone conjugation length and electron withdrawing terminal groups play an important role in the light absorption, energy levels and performance of the devices. Among those molecules, devices using a 7-thiophene-unit backbone and a 3-ethylrhodanine (RD) terminal unit produced a 6.1% PCE. With the optimized conjugation length and terminal unit, we borrowed from the results with P-OPV devices to optimize the backbone. Thus we selected BDT (benzo[1,2-b:4,5-b']dithiophene) and DTS (dithienosilole) to replace the central thiophene unit, leading to a PCE of 8.12%. In addition to our molecules, Bazan and co-workers have developed another excellent system using DTS as the core unit that has also achieved a PCE greater than 8%.

  19. 47 CFR 25.129 - Equipment authorization for portable earth-station transceivers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... equipment certification procedure in part 2, Subpart J of this chapter for importation, sale or lease in the United States, or offer, shipment, or distribution for sale or lease in the United States of portable..., to devices imported, sold, leased, or offered, shipped, or distributed for sale or lease before...

  20. 78 FR 10574 - Premerger Notification; Reporting and Waiting Period Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-14

    ..., patterns, devices, manufacturing processes, or customer names. If you would like the Commission to give... service. Visit the Commission Web site at http://www.ftc.gov to read this Notice and the news release... of a tender offer under Sec. 801.30, that the intention to make the tender offer has been publicly...

  1. A Study of Contextualised Mobile Information Delivery for Language Learning

    ERIC Educational Resources Information Center

    de Jong, Tim; Specht, Marcus; Koper, Rob

    2010-01-01

    Mobile devices offer unique opportunities to deliver learning content in authentic learning situations. Apart from being able to play various kinds of rich multimedia content, they offer new ways of tailoring information to the learner's situation or context. This paper presents the results of a study of mobile media delivery for language…

  2. 9 CFR 381.204 - Marking of poultry products offered for entry; official import inspection marks and devices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION POULTRY PRODUCTS... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Marking of poultry products offered...

  3. Learning with Portable Digital Devices in Australian Schools: 20 Years On!

    ERIC Educational Resources Information Center

    Newhouse, C. Paul

    2014-01-01

    Portable computing technologies such as laptops, tablets, smartphones, wireless networking, voice/stylus input, and plug and play peripheral devices, appear to offer the means of finally realising much of the long heralded vision for computers to support learning in schools. There is the possibility for the technology to finally become a…

  4. A Collaborative Augmented Campus Based on Location-Aware Mobile Technology

    ERIC Educational Resources Information Center

    De Lucia, A.; Francese, R.; Passero, I.; Tortora, G.

    2012-01-01

    Mobile devices are changing the way people work and communicate. Most of the innovative devices offer the opportunity to integrate augmented reality in mobile applications, permitting the combination of the real world with virtual information. This feature can be particularly useful to enhance informal and formal didactic actions based on student…

  5. Specialized Intervention Using Tablet Devices for Communication Deficits in Children with Autism Spectrum Disorders

    ERIC Educational Resources Information Center

    Cabielles-Hernandez, David; Pérez-Pérez, Juan-Ramón; Paule-Ruiz, MPuerto; Fernández-Fernández, Samuel

    2017-01-01

    New possibilities offered by mobile devices for special education students have led to the design of skill acquisition software applications. Advances in mobile technologies development have made progress possible in helping teachers with autistic students modelling and evaluation. "Chain of Words" theoretical basis is the autism…

  6. High-frequency applications of high-temperature superconductor thin films

    NASA Astrophysics Data System (ADS)

    Klein, N.

    2002-10-01

    High-temperature superconducting thin films offer unique properties which can be utilized for a variety of high-frequency device applications in many areas related to the strongly progressing market of information technology. One important property is an exceptionally low level of microwave absorption at temperatures attainable with low power cryocoolers. This unique property has initiated the development of various novel type of microwave devices and commercialized subsystems with special emphasis on application in advanced microwave communication systems. The second important achievement related to efforts in oxide thin and multilayer technology was the reproducible fabrication of low-noise Josephson junctions in high-temperature superconducting thin films. As a consequence of this achievement, several novel nonlinear high-frequency devices, most of them exploiting the unique features of the ac Josephson effect, have been developed and found to exhibit challenging properties to be utilized in basic metrology and Terahertz technology. On the longer timescale, the achievements in integrated high-temperature superconductor circuit technology may offer a strong potential for the development of digital devices with possible clock frequencies in the range of 100 GHz.

  7. Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty.

    PubMed

    Price, A J; Short, A; Kellett, C; Beard, D; Gill, H; Pandit, H; Dodd, C A F; Murray, D W

    2005-11-01

    Polyethylene particulate wear debris continues to be implicated in the aetiology of aseptic loosening following knee arthroplasty. The Oxford unicompartmental knee arthroplasty employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. This study measures the in vivo ten-year linear wear of the device, using a roentgenstereophotogrammetric technique. In this in vivo study, seven medial Oxford unicompartmental prostheses, which had been implanted ten years previously were studied. Stereo pairs of radiographs were acquired for each patient and the films were analysed using a roentgen stereophotogrammetric analysis calibration and a computer-aided design model silhouette-fitting technique. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. In addition, eight control patients were examined less than three weeks post-insertion of an Oxford prosthesis, where no wear would be expected. The control group showed no measured wear and suggested a system accuracy of 0.1 mm. At ten years, the mean linear wear rate was 0.02 mm/year. The results from this in vivo study confirm that the device has low ten-year linear wear in clinical practice. This may offer the device a survival advantage in the long term.

  8. Highly conductive and flexible nano-structured carbon-based polymer nanocomposites with improved electromagnetic-interference-shielding performance

    NASA Astrophysics Data System (ADS)

    Mondal, Subhadip; Ghosh, Sabyasachi; Ganguly, Sayan; Das, Poushali; Ravindren, Revathy; Sit, Subhashis; Chakraborty, Goutam; Das, Narayan Ch

    2017-10-01

    Widespread usage and development of electrical/electronic devices can create severe problems for various other devices and in our everyday lives due to harmful exposure to electromagnetic (EM) radiation. Herein, we report on the electromagnetic interference (EMI)-shielding performance of highly flexible and conductive chlorinated polyethylene (CPE)/carbon nanofiber (CNF) nanocomposites fabricated by a probe-sonication-assisted simple solution-mixing process. The dispersion of CNF nanofillers inside the CPE matrix has been studied by electron micrographs. This dispersion is reflected in the formation of continuous conductive networks at a low percolation-threshold value of 2.87 wt% and promising EMI-shielding performance of 41.5 dB for 25 wt% CNF in the X-band frequency (8.2-12.4 GHz). Such an intriguing performance mainly depends on the unique filler-filler or filler-polymer networks in CPE nanocomposites. In addition, the composite material displays a superior EMI efficiency of 47.5 dB for 2.0 mm thickness at 8.2 GHz. However, we have been encouraged by the promotion of highly flexible and lightweight CPE/CNF nanocomposite as a superior EMI shield, which can protect electronic devices against harm caused by EM radiation and offers an adaptable solution in advanced EMI-shield applications.

  9. Integrated Optical Mach-Zehnder Interferometer Based on Organic-Inorganic Hybrids for Photonics-on-a-Chip Biosensing Applications

    PubMed Central

    Oliveira-Silva, Rui; Silva, Nuno J. O.; André, Paulo S.; Ferreira, Rute A. S.

    2018-01-01

    The development of portable low-cost integrated optics-based biosensors for photonics-on-a-chip devices for real-time diagnosis are of great interest, offering significant advantages over current analytical methods. We report the fabrication and characterization of an optical sensor based on a Mach-Zehnder interferometer to monitor the growing concentration of bacteria in a liquid medium. The device pattern was imprinted on transparent self-patternable organic-inorganic di-ureasil hybrid films by direct UV-laser, reducing the complexity and cost production compared with lithographic techniques or three-dimensional (3D) patterning using femtosecond lasers. The sensor performance was evaluated using, as an illustrative example, E. coli cell growth in an aqueous medium. The measured sensitivity (2 × 10−4 RIU) and limit of detection (LOD = 2 × 10−4) are among the best values known for low-refractive index contrast sensors. Furthermore, the di-ureasil hybrid used to produce this biosensor has additional advantages, such as mechanical flexibility, thermal stability, and low insertion losses due to fiber-device refractive index mismatch (~1.49). Therefore, the proposed sensor constitutes a direct, compact, fast, and cost-effective solution for monitoring the concentration of lived-cells. PMID:29534514

  10. Wave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator.

    PubMed

    Fernández, Enrique J; Prieto, Pedro M; Artal, Pablo

    2009-06-22

    Liquid crystal on Silicon (LCOS) spatial phase modulators offer enhanced possibilities for adaptive optics applications in terms of response velocity and fidelity. Unlike deformable mirrors, they present a capability for reproducing discontinuous phase profiles. This ability also allows an increase in the effective stroke of the device by means of phase wrapping. The latter is only limited by the diffraction related effects that become noticeable as the number of phase cycles increase. In this work we estimated the ranges of generation of the Zernike polynomials as a means for characterizing the performance of the device. Sets of images systematically degraded with the different Zernike polynomials generated using a LCOS phase modulator have been recorded and compared with their theoretical digital counterparts. For each Zernike mode, we have found that image degradation reaches a limit for a certain coefficient value; further increase in the aberration amount has no additional effect in image quality. This behavior is attributed to the intensification of the 0-order diffraction. These results have allowed determining the usable limits of the phase modulator virtually free from diffraction artifacts. The results are particularly important for visual simulation and ophthalmic testing applications, although they are equally interesting for any adaptive optics application with liquid crystal based devices.

  11. Nanofluidic transport through isolated carbon nanotube channels: Advances, controversies, and challenges

    DOE PAGES

    Guo, Shirui; Meshot, Eric R.; Kuykendall, Tevye; ...

    2015-06-02

    Owing to their simple chemistry and structure, controllable geometry, and a plethora of unusual yet exciting transport properties, carbon nanotubes (CNTs) have emerged as exceptional channels for fundamental nanofluidic studies, as well as building blocks for future fluidic devices that can outperform current technology in many applications. Leveraging the unique fluidic properties of CNTs in advanced systems requires a full understanding of their physical origin. Recent advancements in nanofabrication technology enable nanofluidic devices to be built with a single, nanometer-wide CNT as a fluidic pathway. These novel platforms with isolated CNT nanochannels offer distinct advantages for establishing quantitative structure–transport correlationsmore » in comparison with membranes containing many CNT pores. In addition, they are promising components for single-molecule sensors as well as for building nanotube-based circuits wherein fluidics and electronics can be coupled. With such advanced device architecture, molecular and ionic transport can be manipulated with vastly enhanced control for applications in sensing, separation, detection, and therapeutic delivery. Recent achievements in fabricating isolated-CNT nanofluidic platforms are highlighted, along with the most-significant findings each platform enables for water, ion, and molecular transport. Furthermore, the implications of these findings and remaining open questions on the exceptional fluidic properties of CNTs are also discussed.« less

  12. Outsourcing Security Services for Low Performance Portable Devices

    NASA Astrophysics Data System (ADS)

    Szentgyörgyi, Attila; Korn, András

    The number of portable devices using wireless network technologies is on the rise. Some of these devices are incapable of, or at a disadvantage at using secure Internet services, because secure communication often requires comparatively high computing capacity. In this paper, we propose a solution which can be used to offer secure network services for low performance portable devices without severely degrading data transmission rates. We also show that using our approach these devices can utilize some secure network services which were so far unavailable to them due to a lack of software support. In order to back up our claims, we present performance measurement results obtained in a test network.

  13. Protein delivery with infusion pumps.

    PubMed

    Bremer, U; Horres, C R; Francoeur, M L

    1997-01-01

    When a therapeutic effect is optimized by precise control of specific temporal patterns of plasma levels, infusion offers distinct advantages over oral administration, bolus injection, or depot delivery of polypeptides. The limitations of oral delivery are well known, and although research is under way into development of carrier systems that prevent degradation of labile agents, it is unlikely that the variances in absorption will meet the need for precise control. Depot delivery from subcutaneous or intramuscular implants presents a difficult situation when local tissue reactions to the agent sometimes occur. Removal of a depot system in the event of adverse reactions presents additional difficulties. Bolus injections are unable to sustain constant plasma levels unless the drug half-life is long or the injections are frequently administered. Insulin injections, for example, would be required every 30-60 minutes to approximate the plasma levels provided by a continuous infusion; such frequent injections would not be practical on a 24-hour basis. For the developer of new polypeptides, parenteral administration offers the most direct route to the marketplace. The step from periodic injections to tightly controlled infusion is a logical progression as compared with modification of the molecules or vehicles to obtain equivalent profiles. In Table II several different types of devices that can be used for infusion of proteins are compared. Microelectronics have played a major role in the miniaturization of infusion devices and undoubtedly will continue to do so. Micromachining, a spin-off technology of integrated circuit manufacture, will also find application in small infusion devices. In the future, we will have cost-effective disposable devices (Saaman et al., 1994) built on this technology that are programmable and thus can be adapted to meet each individual therapeutic need (Horres, 1994). We can also expect to see more closed-loop drug delivery systems where biosensors and infusion devices are combined to optimize a particular therapy. Recent positive results obtained in diabetics by a decade on tight glucose control may forecast a resurgence of popularity of insulin pumps. At the other end of the spectrum, low-cost, small, and simple-to-use osmotically powered systems are close to being marketed; these systems will make infusion almost as convenient as transdermal patches. We will also see major advances in how drugs and devices are interfaced. Prefilled and ready-to-use drug cartridges have proven to be efficient in surgical and emergency medicine and can greatly improve most infusion applications. It is anticipated that coded, prefilled cartridges or pouches will be automatically, recognized by preprogrammed pumps to reduce operator labor and entry error.

  14. Magnetic-field-controlled reconfigurable semiconductor logic.

    PubMed

    Joo, Sungjung; Kim, Taeyueb; Shin, Sang Hoon; Lim, Ju Young; Hong, Jinki; Song, Jin Dong; Chang, Joonyeon; Lee, Hyun-Woo; Rhie, Kungwon; Han, Suk Hee; Shin, Kyung-Ho; Johnson, Mark

    2013-02-07

    Logic devices based on magnetism show promise for increasing computational efficiency while decreasing consumed power. They offer zero quiescent power and yet combine novel functions such as programmable logic operation and non-volatile built-in memory. However, practical efforts to adapt a magnetic device to logic suffer from a low signal-to-noise ratio and other performance attributes that are not adequate for logic gates. Rather than exploiting magnetoresistive effects that result from spin-dependent transport of carriers, we have approached the development of a magnetic logic device in a different way: we use the phenomenon of large magnetoresistance found in non-magnetic semiconductors in high electric fields. Here we report a device showing a strong diode characteristic that is highly sensitive to both the sign and the magnitude of an external magnetic field, offering a reversible change between two different characteristic states by the application of a magnetic field. This feature results from magnetic control of carrier generation and recombination in an InSb p-n bilayer channel. Simple circuits combining such elementary devices are fabricated and tested, and Boolean logic functions including AND, OR, NAND and NOR are performed. They are programmed dynamically by external electric or magnetic signals, demonstrating magnetic-field-controlled semiconductor reconfigurable logic at room temperature. This magnetic technology permits a new kind of spintronic device, characterized as a current switch rather than a voltage switch, and provides a simple and compact platform for non-volatile reconfigurable logic devices.

  15. A smart spirometry device for asthma diagnosis.

    PubMed

    Kassem, A; Hamad, M; El Moucary, C

    2015-08-01

    In this paper an innovative prototype for smart asthma spirometry device to be used by doctors and asthma patients is presented. The novelty in this prototype relies in the fact that it is destined to subtend not only adults but offers an efficient and attractive manner to accommodate children patients as well thus, making it efficient for doctors, patients and parents to detect and monitor such intricate cases at stages as early as six years old. Moreover, the apparatus used enables us to integrate a vital parameter representing the Forced Expiratory Volume to the final diagnosis. Besides, the presented device will automatically diagnose those patients, assess their asthma condition, and schedule their medication process without excessive visits to medical centers whilst providing doctors with accurate and pertinent and comprehensive medical data in a chronological fashion. Zooming into under the hood of the device, a fully reliable hardware digital system lies along with a flowmeter detector and a Bluetooth emitter to interface with a user-friendly GUI-based application installed on smartphones which incorporates appealing animated graphics to encourage children to take the test. Furthermore, the device offers the capability of storing chronological data and a relevant resourceful display for accurate tracking of patients' medical record, the evolvement of their asthma condition, and the administered medication. Finally, the entire device is aligned with the medical requirements as per doctors' and telemedicine specialists' recommendations; the experiments carried out demonstrated the effectiveness and sustainable use of such device.

  16. Bio-microfluidics: biomaterials and biomimetic designs.

    PubMed

    Domachuk, Peter; Tsioris, Konstantinos; Omenetto, Fiorenzo G; Kaplan, David L

    2010-01-12

    Bio-microfluidics applies biomaterials and biologically inspired structural designs (biomimetics) to microfluidic devices. Microfluidics, the techniques for constraining fluids on the micrometer and sub-micrometer scale, offer applications ranging from lab-on-a-chip to optofluidics. Despite this wealth of applications, the design of typical microfluidic devices imparts relatively simple, laminar behavior on fluids and is realized using materials and techniques from silicon planar fabrication. On the other hand, highly complex microfluidic behavior is commonplace in nature, where fluids with nonlinear rheology flow through chaotic vasculature composed from a range of biopolymers. In this Review, the current state of bio-microfluidic materials, designs and applications are examined. Biopolymers enable bio-microfluidic devices with versatile functionalization chemistries, flexibility in fabrication, and biocompatibility in vitro and in vivo. Polymeric materials such as alginate, collagen, chitosan, and silk are being explored as bulk and film materials for bio-microfluidics. Hydrogels offer options for mechanically functional devices for microfluidic systems such as self-regulating valves, microlens arrays and drug release systems, vital for integrated bio-microfluidic devices. These devices including growth factor gradients to study cell responses, blood analysis, biomimetic capillary designs, and blood vessel tissue culture systems, as some recent examples of inroads in the field that should lead the way in a new generation of microfluidic devices for bio-related needs and applications. Perhaps one of the most intriguing directions for the future will be fully implantable microfluidic devices that will also integrate with existing vasculature and slowly degrade to fully recapitulate native tissue structure and function, yet serve critical interim functions, such as tissue maintenance, drug release, mechanical support, and cell delivery.

  17. Commercialization of microfluidic devices.

    PubMed

    Volpatti, Lisa R; Yetisen, Ali K

    2014-07-01

    Microfluidic devices offer automation and high-throughput screening, and operate at low volumes of consumables. Although microfluidics has the potential to reduce turnaround times and costs for analytical devices, particularly in medical, veterinary, and environmental sciences, this enabling technology has had limited diffusion into consumer products. This article analyzes the microfluidics market, identifies issues, and highlights successful commercialization strategies. Addressing niche markets and establishing compatibility with existing workflows will accelerate market penetration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. PERKAT RV: first in vivo data of a novel right heart assist device.

    PubMed

    Kretzschmar, Daniel; Lauten, Alexander; Schubert, Harald; Bischoff, Sabine; Schulze, Christian; Ferrari, Markus W

    2018-04-06

    Mechanical right ventricular (RV) support offers a treatment option for critically ill patients with RV failure (RVF). We developed an assist device for rapid percutaneous implantation. The aim of the present study was to investigate the implantation procedure, haemodynamic performance and possible side effects of the novel right ventricular assist device - PERKAT RV - in an animal model. The PERkutane KATheterpumptechnologie RV (PERKAT RV) device consists of a nitinol chamber covered by foil containing inflow valves. An outlet tube is attached to its distal part. The system is designed for 18 Fr percutaneous implantation. The chamber is unfolded in the inferior vena cava while the outlet tube bypasses the right heart with the tip in the pulmonary trunk. An IABP balloon is placed inside. Balloon deflation generates blood flow into the chamber; during inflation, blood is guided into the pulmonary arteries. Acute RVF was induced by venous injection of Sephadex in seven sheep for evaluation of the device. The PERKAT RV was able to improve haemodynamics immediately generating a median increase in cardiac output of 59%. Longer pump support was evaluated in a second study. Four sheep were supported for eight hours without any problems. The percutaneous implantation and explantation of the PERKAT RV device was possible in the designed way. The sheep studies proved beneficial haemodynamic effects in acute RVF. The system offers easy and safe treatment in acute RVF.

  19. Maintaining persistence and adherence with subcutaneous growth-hormone therapy in children: comparing jet-delivery and needle-based devices.

    PubMed

    Spoudeas, Helen A; Bajaj, Priti; Sommerford, Nathan

    2014-01-01

    Persistence and adherence with subcutaneous growth hormone (GH; somatropin) therapy in children is widely acknowledged to be suboptimal. This study aimed to investigate how the use of a jet-delivery device, ZomaJet(®), impacts on medication-taking behaviors compared to needle-based devices. A retrospective cohort study of children aged ≤18 years was conducted using a UK-based, nationwide database of GH home-delivery schedules. Data were evaluated for the period between January 2010 and December 2012 for 6,061 children receiving either Zomacton(®) (somatropin) via the ZomaJet jet-delivery device or one of six brands of GH all administered via needle-based devices. Persistence was analyzed for patients with appropriate data, measured as the time interval between first and last home deliveries. An analysis of adherence was conducted only for patients using ZomaJet who had appropriate data, measured by proportion of days covered. Brand switches were identified for all patients. Persistence with GH therapy was significantly longer in patients using ZomaJet compared to needle-based devices (599 days versus 535 days, respectively, n=4,093; P<0.001); this association was observed in both sexes and across age subgroups (≤10 and 11-16 years). The majority (58%) of patients using ZomaJet were classed as adherent (n=728). Only 297 patients (5%) switched GH brand (n=6,061), and patients tended to use ZomaJet for longer than other devices before switching. It appears important that the choice of a jet-delivery device is offered to children prescribed daily GH therapy. These devices may represent a much-needed effective strategy for maintaining persistence with subcutaneous GH administration in children, potentially offering better clinical outcomes and greater cost-efficiency.

  20. Photoelectrochemical performance of NiO-coated ZnO-CdS core-shell photoanode

    NASA Astrophysics Data System (ADS)

    Iyengar, Pranit; Das, Chandan; Balasubramaniam, K. R.

    2017-03-01

    A nano-structured core-shell ZnO-CdS photoanode device with a mesoporous NiO co-catalyst layer was fabricated using solution-processing methods. The growth of the sparse ZnO nano-rod film with a thickness of ca. 930 nm was achieved by optimizing parameters such as the thickness of the ZnO seed layer, choice of Zn precursor salt and the salt concentration. CdS was then coated by a combination of spin coating and spin SILAR (Successive Ionic Layer Adsorption and Reaction) methods to completely fill the interspace of ZnO nano-rods. The uniform CdS surface facilitated the growth of a continuous mesoporous NiO layer. Upon illumination of 100 mW·cm-2 AM 1.5 G radiation the device exhibits stable photocurrents of 2.15 mA·cm-2 at 1.23 V and 0.92 mA·cm-2 at 0.00 V versus RHE, which are significantly higher as compared to the bare ZnO-CdS device. The excellent performance of the device can be ascribed to the higher visible region absorption by CdS, and effective separation of the photogenerated charge carriers due to the suitable band alignment and nanostructuring. Additionally, the mesoporous NiO overlayer offered a larger contact area with the electrolyte and promoted the kinetics enabling higher and stable photocurrent even till the 35th min. of testing.

  1. Surface texture change on-demand and microfluidic devices based on thickness mode actuation of dielectric elastomer actuators (DEAs)

    NASA Astrophysics Data System (ADS)

    Ankit, Ankit; Nguyen, Anh Chien; Mathews, Nripan

    2017-04-01

    Tactile feedback devices and microfluidic devices have huge significance in strengthening the area of robotics, human machine interaction and low cost healthcare. Dielectric Elastomer Actuators (DEAs) are an attractive alternative for both the areas; offering the advantage of low cost and simplistic fabrication in addition to the high actuation strains. The inplane deformations produced by the DEAs can be used to produce out-of-plane deformations by what is known as the thickness mode actuation of DEAs. The thickness mode actuation is achieved by adhering a soft passive layer to the DEA. This enables a wide area of applications in tactile applications without the need of complex systems and multiple actuators. But the thickness mode actuation has not been explored enough to understand how the deformations can be improved without altering the material properties; which is often accompanied with increased cost and a trade off with other closely associated material properties. We have shown the effect of dimensions of active region and non-active region in manipulating the out-of-plane deformation. Making use of this, we have been able to demonstrate large area devices and complex patterns on the passive top layer for the surface texture change on-demand applications. We have also been able to demonstrate on-demand microfluidic channels and micro-chambers without the need of actually fabricating the channels; which is a cost incurring and cumbersome process.

  2. Aqueous gradient by balancing diffusive and convective mass transport (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Habhab, Mohammed-Baker I.; Ismail, Tania; Lo, Joe F.; Haque, Arefa

    2016-03-01

    In wounds, cells secret biomolecules such as vascular endothelial growth factor (VEGF), a protein that controls many processes in healing. VEGF protein is expressed in a gradient in tissue, and its shape will be affected by the tissue injury sustained during wounding. In order to study the responses of keratinocyte cell migration to VEGF gradients and the geometric factors on wound healing, we designed a microfluidic gradient device that can generate large area gradients (1.5 cm in diameter) capable of mimicking arbitrary wound shapes. Microfluidic devices offer novel techniques to address biological and biomedical issues. Different from other gradient microfluidics, our device balances diffusion of biomolecules versus the convective clearance by a buffer flow on the opposite ends of the gradient. This allows us to create a large area gradient within shorter time scales by actively driving mass transport. In addition, the microfluidic device makes use of a porous filter membrane to create this balance as well as to deliver the resulting gradient to a culture of cells. The culture of cells are seeded above the gradient in a gasket chamber. However, Keratinocytes do not migrate effectively on filter paper. Therefore, in order to improve the motility of cells on the surface, we coated the filter paper with a 30m thick layer of gelatin type B. after observation under the microscope we found that the gelatin coated sample showed cells with more spread out morphology, with 97% viability, suggesting better adhesion than the non-coated sample.

  3. Safety, efficacy, and usage compliance of home-use device utilizing RF and light energies for treating periorbital wrinkles.

    PubMed

    Gold, Michael H; Biron, Julie; Levi, Liora; Sensing, Whitney

    2017-03-01

    The aging process is often associated with undesirable effects on facial skin such as skin redundancy, reduction of elasticity, and increased wrinkling. Radiofrequency (RF) and light-emitting diodes (LEDs) are widely used, clinically proven technologies for skin rejuvenation. This study aimed to evaluate the safety, efficacy, and usage compliance of the home-use device, utilizing RF and LED energies, for self-treatment of periorbital wrinkles and improvement of skin appearance. Thirty-three subjects performed 21 treatment sessions every other day, over 6 weeks on the periorbital areas. In addition, two maintenance treatments were conducted 1 and 2 months following treatment end. Each subject served as his/her own control, comparing results before treatment, and 3 months following treatment end. Thirty subjects completed the study. A blinded, independent photographs assessment of three dermatologists demonstrated an average reduction of 1.49 Fitzpatrick scores (P < 0.001). Analysis revealed improvement (downgrade of at least 1 score) in almost all subjects. No unexpected adverse events were reported. Post-treatment erythema was seen in all subjects and disappeared within 1 h. In some subjects, post-treatment edema was detected and resolved within 24 h. High satisfaction with the device operation, ease of treatments, safety, and wrinkle reduction was reported. The Silk'n Home Skin Tightening (HST) device offers a safe and effective in-home noninvasive technique to improve the appearance of age-related periorbital wrinkles. © 2016 Wiley Periodicals, Inc.

  4. Potential Space Applications for Body-Centric Wireless and E-Textile Antennas

    NASA Technical Reports Server (NTRS)

    Kennedy, Timothy F.; Fink, Patrick W.; Chu, Andrew W.; Studor, George F.

    2007-01-01

    Space environment benefits of body-centric wireless communications are numerous, particularly in the context of long duration Lunar and Martian outposts that are in planning stages at several space agencies around the world. Since crew time for such missions is a scarce commodity, seamless integration of body-centric wireless from various sources is paramount. Sources include traditional data, such as audio, video, tracking, and biotelemetry. Newer data sources include positioning, orientation, and status of handheld tools and devices, as well as management and status of on-body inventories. In addition to offering lighter weight and flexibility, performance benefits of e-textile antennas are anticipated due to advantageous use of the body s surface area. In creating e-textile antennas and RF devices, researchers are faced with the challenge of transferring conventional and novel designs to textiles. Lack of impedance control, limited conductivity, and the inability to automatically create intricate designs are examples of limitations frequently attributed to e-textiles. Reliable interfaces between e-textiles and conventional hardware also represent significant challenges. Addressing these limitations is critical to the continued development and acceptance of fabric-based circuits for body-centric wireless applications. Here we present several examples of e-textile antennas and RF devices, created using a NASA-developed process, that overcome several of these limitations. The design and performance of an equiangular spiral, miniaturized spiral-loaded slot antenna, and a hybrid coupler are considered, with the e-textile devices showing comparable performance to like designs using conventional materials.

  5. Self-Assembly High-Performance UV-vis-NIR Broadband β-In2Se3/Si Photodetector Array for Weak Signal Detection.

    PubMed

    Zheng, Zhaoqiang; Yao, Jiandong; Wang, Bing; Yang, Yibin; Yang, Guowei; Li, Jingbo

    2017-12-20

    The emergence of a rich variety of layered materials has attracted considerable attention in recent years because of their exciting properties. However, the applications of layered materials in optoelectronic devices are hampered by the low light absorption of monolayers/few layers, the lack of p-n junction, and the challenges for large-scale production. Here, we report a scalable production of β-In 2 Se 3 /Si heterojunction arrays using pulsed-laser deposition. Photodetectors based on the as-produced heterojunction array are sensitive to a broadband wavelength from ultraviolet (370 nm) to near-infrared (808 nm), showing a high responsivity (5.9 A/W), a decent current on/off ratio (∼600), and a superior detectivity (4.9 × 10 12 jones), simultaneously. These figures-of-merits are among the best values of the reported heterojunction-based photodetectors. In addition, these devices can further enable the detection of weak signals, as successfully demonstrated with weak light sources including a flashlight, lighter, and fluorescent light. Device physics modeling shows that their high performance is attributed to the strong light absorption of the relatively thick β-In 2 Se 3 film (20.3 nm) and the rational energy band structures of β-In 2 Se 3 and Si, which allows efficient separation of photoexcited electron-hole pairs. These results offer a new insight into the rational design of optoelectronic devices from the synergetic effect of layered materials as well as mature semiconductor technology.

  6. New culture devices in ART.

    PubMed

    Rienzi, L; Vajta, G; Ubaldi, F

    2011-09-01

    During the past decades, improvements in culture of preimplantation embryos have contributed substantially in the success of human assisted reproductive techniques. However, most efforts were focused on optimization of media and gas components, while the established physical conditions and applied devices have remained essentially unchanged. Very recently, however, intensive research has been started to provide a more appropriate environment for the embryos and to replace the rather primitive and inappropriate devices with more sophisticated and practical instruments. Success has been reported with simple or sophisticated tools (microwells or microchannels) that allow accumulation of autocrine factors and establishment of a proper microenvironment for embryos cultured individually or in groups. The microchannel system may also offer certain level of automation and increased standardization of culture parameters. Continuous monitoring of individual embryos by optical or biochemical methods may help to determine the optimal day of transfer, and selection of the embryo with highest developmental competence for transfer. This advancement may eventually lead to adjustment of the culture environment to each individual embryo according to its actual needs. Connection of these techniques to additional radical approaches as automated ICSI or an ultimate assisted hatching with full removal of the zona pellucida after or even before fertilization may result in devices with high reliability and consistency, to increase the overall efficiency and decrease the work-intensity, and to eliminate the existing technological gap between laboratory embryology work and most other fields of biomedical sciences. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. AN E-TEXTILE SYSTEM FOR MOTION ANALYSIS

    PubMed Central

    EDMISON, Josh; JONES, Mark; LOCKHART, Thurmon; MARTIN, Thomas

    2010-01-01

    Electronic textiles (e-textiles) offer the promise of home health care devices that integrate seamlessly into the wearer’s everyday lifestyle while providing a higher level of functionality than current devices. Existing gait analysis systems are cumbersome laboratory-based systems that, while providing valuable information, would be difficult or impossible to deploy in the home. Yet gait analysis systems offer the promise of preventing and/or mitigating the serious effects of falls in the elderly population. This paper proposes an e-textile solution to this problem along with a design approach for realizing a solution that is inexpensive and usable across the elderly population. Preliminary results are given to demonstrate the promise of the proposed system. PMID:15718659

  8. Three-terminal graphene negative differential resistance devices.

    PubMed

    Wu, Yanqing; Farmer, Damon B; Zhu, Wenjuan; Han, Shu-Jen; Dimitrakopoulos, Christos D; Bol, Ageeth A; Avouris, Phaedon; Lin, Yu-Ming

    2012-03-27

    A new mechanism for negative differential resistance (NDR) is discovered in three-terminal graphene devices based on a field-effect transistor configuration. This NDR effect is a universal phenomenon for graphene and is demonstrated in devices fabricated with different types of graphene materials and gate dielectrics. Operation of conventional NDR devices is usually based on quantum tunneling or intervalley carrier transfer, whereas the NDR behavior observed here is unique to the ambipolar behavior of zero-bandgap graphene and is associated with the competition between electron and hole conduction as the drain bias increases. These three terminal graphene NDR devices offer more operation flexibility than conventional two-terminal devices based on tunnel diodes, Gunn diodes, or molecular devices, and open up new opportunities for graphene in microwave to terahertz applications. © 2012 American Chemical Society

  9. Security Frameworks for Machine-to-Machine Devices and Networks

    NASA Astrophysics Data System (ADS)

    Demblewski, Michael

    Attacks against mobile systems have escalated over the past decade. There have been increases of fraud, platform attacks, and malware. The Internet of Things (IoT) offers a new attack vector for Cybercriminals. M2M contributes to the growing number of devices that use wireless systems for Internet connection. As new applications and platforms are created, old vulnerabilities are transferred to next-generation systems. There is a research gap that exists between the current approaches for security framework development and the understanding of how these new technologies are different and how they are similar. This gap exists because system designers, security architects, and users are not fully aware of security risks and how next-generation devices can jeopardize safety and personal privacy. Current techniques, for developing security requirements, do not adequately consider the use of new technologies, and this weakens countermeasure implementations. These techniques rely on security frameworks for requirements development. These frameworks lack a method for identifying next generation security concerns and processes for comparing, contrasting and evaluating non-human device security protections. This research presents a solution for this problem by offering a novel security framework that is focused on the study of the "functions and capabilities" of M2M devices and improves the systems development life cycle for the overall IoT ecosystem.

  10. All-spin logic operations: Memory device and reconfigurable computing

    NASA Astrophysics Data System (ADS)

    Patra, Moumita; Maiti, Santanu K.

    2018-02-01

    Exploiting spin degree of freedom of electron a new proposal is given to characterize spin-based logical operations using a quantum interferometer that can be utilized as a programmable spin logic device (PSLD). The ON and OFF states of both inputs and outputs are described by spin state only, circumventing spin-to-charge conversion at every stage as often used in conventional devices with the inclusion of extra hardware that can eventually diminish the efficiency. All possible logic functions can be engineered from a single device without redesigning the circuit which certainly offers the opportunities of designing new generation spintronic devices. Moreover, we also discuss the utilization of the present model as a memory device and suitable computing operations with proposed experimental setups.

  11. Developing Confidence in the Use of Digital Tools in Teaching

    ERIC Educational Resources Information Center

    Greener, Sue; Wakefield, Craig

    2015-01-01

    In this study Higher Education teachers were offered new mobile devices with very few conditions attached. The aim was to introduce staff to mobile technology and how it could be used to support teaching and learning within a small, interdisciplinary campus. The study hypothesized that by offering staff the simple incentive of new mobile devices…

  12. 12 CFR 16.32 - Fraudulent transactions and unsafe and unsound practices.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... operates as a fraud or deceit upon any person, in connection with the purchase or sale of any security of a... SECURITIES OFFERING DISCLOSURE RULES § 16.32 Fraudulent transactions and unsafe and unsound practices. (a) No person in the offer or sale of bank securities shall directly or indirectly: (1) Employ any device...

  13. Set Super-Chicken to 3! Student and Teacher Perceptions of Spaceteam ESL

    ERIC Educational Resources Information Center

    Cardoso, Walcir; Grimshaw, Jennica; Waddington, David

    2015-01-01

    Digital gaming in education is an area that has been rapidly expanding in popularity and is gradually being applied to second language (L2) contexts (Godwin-Jones, 2014). Mobile gaming in particular offers the benefits of digital gaming while also offering the portability and accessibility of mobile devices (Ogata & Yana, 2003; Stockwell,…

  14. Socio-economic analysis of cardiac resynchronization therapy.

    PubMed

    Field, Michael E; Sweeney, Michael O

    2006-12-01

    The field of electrical device therapy has benefited from two basically independent lines of investigation demonstrating mortal benefit from either cardiac resynchronization therapy (CRT) or implantable cardioverter-defibrillator (ICD) therapy in patients with heart failure. Current clinical evidence data is insufficient to conclude that CRT-defibrillation (CRTD) offers an advantage over CRT-pacing (CRTP) alone. The cost of adding a defibrillator to the CRTP device is substantial and will act as a barrier to wide scale penetration. Annualized sudden death rates are very low in certain primary prevention populations. Consequently, the potential for overtreatment is very large and the negative costs of ICD therapy are distributed equally among those patients who will have a life saving benefit and those who were "destined" never to require the therapy. The perception that these costs are acceptable if lives are saved is commonly cited as justification for expensive therapy on a population scale, but there is an important and practical difference between costs per unit life saved and costs among patients who really never needed the device. Until the a priori predictors of volumetric response to CRT are better understood, the use of CRTD in class IV patients should be discouraged since ICD therapy is unlikely to extend life in volumetric non-responders. Similarly, the use of CRTD in patients who are "destined" for significant volumetric response is probably unwise since their risk of sudden death is minimized due to favorable substrate modification. Clinical trials comparing conventional ICDs, CRTP and CRTD are necessary to rationalize use of expensive hardware resources among different patient populations. Additionally, the importance of patient preference regarding end of life care should receive greater emphasis. While CRTP may be considered palliative in terminal heart failure, the decision to offer CRTD must include a discussion with the patient regarding mode of death and the potential for the defibrillator to replace a sudden and peaceful death with a prolonged death from progressive pump failure.

  15. Water/alcohol soluble conjugated polymers as highly efficient electron transporting/injection layer in optoelectronic devices.

    PubMed

    Huang, Fei; Wu, Hongbin; Cao, Yong

    2010-07-01

    Water/alcohol soluble conjugated polymers (WSCPs) can be processed from water or other polar solvents, which offer good opportunities to avoid interfacial mixing upon fabrication of multilayer polymer optoelectronic devices by solution processing, and can dramatically improve charge injection from high work-function metal cathode resulting in greatly enhancement of the device performance. In this critical review, the authors provide a brief review of recent developments in this field, including the materials design, functional principles, and their unique applications as interface modification layer in solution-processable multilayer optoelectronic devices (135 references).

  16. Improved Electromechanical Infrared Sensor

    NASA Technical Reports Server (NTRS)

    Kenny, Thomas W.; Kaiser, William J.

    1994-01-01

    Proposed electromechanical infrared detector improved version of device described in "Micromachined Electron-Tunneling Infrared Detectors" (NPO-18413). Fabrication easier, and undesired sensitivity to acceleration reduced. In devices, diaphragms and other components made of micromachined silicon, and displacements of diaphragms measured by electron tunneling displacement transducer {see "Micromachined Tunneling Accelerometer" (NPO-18513)}. Improved version offers enhanced frequency response and less spurious response to acceleration.

  17. Fast Neural Solution Of A Nonlinear Wave Equation

    NASA Technical Reports Server (NTRS)

    Barhen, Jacob; Toomarian, Nikzad

    1996-01-01

    Neural algorithm for simulation of class of nonlinear wave phenomena devised. Numerically solves special one-dimensional case of Korteweg-deVries equation. Intended to be executed rapidly by neural network implemented as charge-coupled-device/charge-injection device, very-large-scale integrated-circuit analog data processor of type described in "CCD/CID Processors Would Offer Greater Precision" (NPO-18972).

  18. 75 FR 13172 - Self-Regulatory Organizations; The NASDAQ Stock Market LLC; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... internal distributors count and report each server and display device that processes TotalView-ITCH data as a professional TotalView and OpenView user. Some firms report upwards of 500 devices, while other.... Nasdaq has offered similar enterprise licenses for professional and non-professional usage of TotalView...

  19. Libraries and the Mobile Web

    ERIC Educational Resources Information Center

    Hanson, Cody

    2011-01-01

    In 2011, cell phones and mobile devices are ubiquitous. The vast majority of Americans now own cell phones, and over half of them have mobile access to the Internet through a phone or other mobile device. For libraries to stay relevant, they must be able to offer content and services through the mobile web. In this issue of "Library Technology…

  20. Evaluation of a hybrid pixel detector for electron microscopy.

    PubMed

    Faruqi, A R; Cattermole, D M; Henderson, R; Mikulec, B; Raeburn, C

    2003-04-01

    We describe the application of a silicon hybrid pixel detector, containing 64 by 64 pixels, each 170 microm(2), in electron microscopy. The device offers improved resolution compared to CCDs along with faster and noiseless readout. Evaluation of the detector, carried out on a 120 kV electron microscope, demonstrates the potential of the device.

  1. Tablet and phone applications--A reflection on the experience of development.

    PubMed

    Edwards, Simon; Winckles, Derek; Leonard, Mark

    2015-06-01

    Tablet devices are now ubiquitous. Medical illustrators have the skills to produce a wide range of media content. These devices offer the potential of using their creative abilities in new and exciting ways. There is much to explore. The primary difficulty lies in understanding the necessary computer technical skills to realise a vision.

  2. Activity Theory Approach to Developing Context-Aware Mobile Learning Systems for Understanding Scientific Phenomenon and Theories

    ERIC Educational Resources Information Center

    Uden, Lorna; Hwang, Gwo-Jen

    2013-01-01

    Mobile computing offers potential opportunities for students' learning especially when it combines a sensing device such as RFID (Radio Frequency Identification). Researchers have indicated that a key feature of in-field learning supported by mobile devices and technology is context awareness, with which context and functionality provided by…

  3. Student Perceptions of Engagement Using Mobile-Based Polling as an Audience Response System: Implications for Leadership Studies

    ERIC Educational Resources Information Center

    Noel, Dan; Stover, Sheri; McNutt, Mindy

    2015-01-01

    The increase in ownership and use of mobile-based devices among college students creates unique opportunities for faculty to develop highly engaging learning environments. With many educational institutions offering campus-wide Wi-Fi, students have the ability to use their mobile devices, including cell phones, tablets, and laptops for engaging…

  4. 47 CFR 2.803 - Marketing of radio frequency devices prior to equipment authorization.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... device that is in the conceptual, developmental, design or pre-production stage may be offered for sale...) The following notice is included with the kit: FCC NOTICE: This kit is designed to allow: (1) Product... stations and that this product accept harmful interference. Unless the assembled kit is designed to operate...

  5. [A new system of testing visual performance based on the cylindrical lens screen].

    PubMed

    Doege, E; Krause, O

    1983-09-01

    Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.

  6. Flexible Fe3O4@Carbon Nanofibers Hierarchically Assembled with MnO2 Particles for High-Performance Supercapacitor Electrodes.

    PubMed

    Iqbal, Nousheen; Wang, Xianfeng; Babar, Aijaz Ahmed; Zainab, Ghazala; Yu, Jianyong; Ding, Bin

    2017-11-09

    Increasing use of wearable electronic devices have resulted in enhanced demand for highly flexible supercapacitor electrodes with superior electrochemical performance. In this study, flexible composite membranes with electrosprayed MnO 2 particles uniformly anchored on Fe 3 O 4 doped electrospun carbon nanofibers (Fe 3 O 4 @CNF Mn ) have been prepared as flexible electrodes for high-performance supercapacitors. The interconnected porous beaded structure ensures free movement of electrolyte within the composite membranes, therefore, the developed supercapacitor electrodes not only offer high specific capacitance of ~306 F/g, but also exhibit good capacitance retention of ~85% after 2000 cycles, which certify that the synthesized electrodes offer high and stable electrochemical performance. Additionally, the supercapacitors fabricated from our developed electrodes well maintain their performance under flexural stress and exhibit a very minute change in specific capacitance even up to 180° bending angle. The developed electrode fabrication strategy integrating electrospinning and electrospray techniques paves new insights into the development of potential functional nanofibrous materials for light weight and flexible wearable supercapacitors.

  7. Nanofluidics: A New Arena for Materials Science.

    PubMed

    Xu, Yan

    2018-01-01

    A significant growth of research in nanofluidics is achieved over the past decade, but the field is still facing considerable challenges toward the transition from the current physics-centered stage to the next application-oriented stage. Many of these challenges are associated with materials science, so the field of nanofluidics offers great opportunities for materials scientists to exploit. In addition, the use of unusual effects and ultrasmall confined spaces of well-defined nanofluidic environments would offer new mechanisms and technologies to manipulate nanoscale objects as well as to synthesize novel nanomaterials in the liquid phase. Therefore, nanofluidics will be a new arena for materials science. In the past few years, burgeoning progress has been made toward this trend, as overviewed in this article, including materials and methods for fabricating nanofluidic devices, nanofluidics with functionalized surfaces and functional material components, as well as nanofluidics for manipulating nanoscale materials and fabricating new nanomaterials. Many critical challenges as well as fantastic opportunities in this arena lie ahead. Some of those, which are of particular interest, are also discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Metal-Organic Heat Carrier Nanofluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGrail, B. Peter; Thallapally, Praveen K.; Blanchard, Jeremy

    2013-09-01

    Nanofluids, dispersions of metal or oxide nanoparticles in a base working fluid, are being intensively studied due to improvements they offer in thermal properties of the working fluid. However, these benefits have been erratically demonstrated and proven impacts on thermal conductivity are modest and well described from long-established effective medium theory. In this paper, we describe a new class of metal-organic heat carrier (MOHC) nanofluid that offers potential for a larger performance boost in thermal vapor-liquid compression cycles. MOHCs are nanophase porous coordination solids designed to reversibly uptake the working fluid molecules in which the MOHCs are suspended. Additional heatmore » can be extracted in a heat exchanger or solar collector from the endothermic enthalpy of desorption, which is then released as the nanofluid transits through a power generating device such as a turboexpander. Calculations for an R123 MOHC nanofluid indicated potential for up to 15% increase in power output. Capillary tube experiments show that liquid-vapor transitions occur without nanoparticle deposition on the tube walls provided entrance Reynolds number exceeds approximately 100.« less

  9. Antibiotics/antimicrobials: systemic and local administration in the therapy of mild to moderately advanced periodontitis.

    PubMed

    Jepsen, Karin; Jepsen, Søren

    2016-06-01

    This review gives an update of the current scientific evidence on the efficacy of the adjunctive use of systemic and local antibiotics/antimicrobials in the treatment of periodontitis. In particular, it addresses whether their use can improve the results of nonsurgical mechanical therapy in mild-to-moderate forms of the disease. Large numbers of randomized clinical trials and systematic reviews with meta-analyses have clearly established that adjunctive systemic antibiotics, combined with mechanical debridement, offer clinical improvements additional to those obtained with scaling and root planing alone. These effects are more pronounced in aggressive periodontitis and in initially deep pockets, whereas more limited additional improvements, of 0.3 mm for additional pocket reduction and 0.2 mm for additional clinical attachment gain, have been documented for moderately deep sites (4-6 mm) in patients with chronic periodontitis. The marginal clinical benefit in patients with moderate disease has to be balanced against possible side effects. Notably, it has to be realized that an increasing number of warnings have been articulated against the unrestricted use of antibiotics in treating periodontal diseases because of the emerging global public health issue of bacterial resistance. The effects of the adjunctive local administration of antimicrobials have also been very well documented in several systematic reviews. Overall, in persistent or recurrent localized deep sites, the application of antimicrobials by sustained-delivery devices may offer a benefit of an additional 0.4 mm in pocket depth reduction and 0.3 mm in clinical attachment level gain. In conclusion, the slight additional benefits of adjunctive antimicrobials, which were shown for moderate forms of periodontitis, have to be balanced against their side effects and therefore their prescription should be limited as much as possible. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. [A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation].

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anaesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical assisted intubation compared to other devices. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  11. A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation.

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical assisted intubation compared to other devices. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  12. On Location Estimation Technique Based of the Time of Flight in Low-power Wireless Systems

    NASA Astrophysics Data System (ADS)

    Botta, Miroslav; Simek, Milan; Krajsa, Ondrej; Cervenka, Vladimir; Pal, Tamas

    2015-04-01

    This study deals with the distance estimation issue in low-power wireless systems being usually used for sensor networking and interconnecting the Internet of Things. There is an effort to locate or track these sensor entities for different needs the radio signal time of flight principle from the theoretical and practical side of application research is evaluated. Since these sensor devices are mainly targeted for low power consumption appliances, there is always need for optimization of any aspects needed for regular sensor operation. For the distance estimation we benefit from IEEE 802.15.4a technology, which offers the precise ranging capabilities. There is no need for additional hardware to be used for the ranging task and all fundamental measurements are acquired within the 15.4a standard compliant hardware in the real environment. The proposed work examines the problems and the solutions for implementation of distance estimation algorithms for WSN devices. The main contribution of the article is seen in this real testbed evaluation of the ranging technology.

  13. Anisotropy of the nitrogen conduction states in the group III nitrides studied by polarized x-ray absorption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawniczak-Jablonska, K.; Liliental-Weber, Z.; Gullikson, E.M.

    1997-04-01

    Group III nitrides (AlN, GaN, and InN) consist of the semiconductors which appear recently as a basic materials for optoelectronic devices active in the visible/ultraviolet spectrum as well as high-temperature and high-power microelectronic devices. However, understanding of the basic physical properties leading to application is still not satisfactory. One of the reasons consists in unsufficient knowledge of the band structure of the considered semiconductors. Several theoretical studies of III-nitrides band structure have been published but relatively few experimental studies have been carried out, particularly with respect to their conduction band structure. This motivated the authors to examine the conduction bandmore » structure projected onto p-states of the nitrogen atoms for AlN, GaN and InN. An additional advantage of their studies is the availability of the studied nitrides in two structures, hexagonal (wurtzite) and cubic (zincblende). This offers an opportunity to gain information about the role of the anisotropy of electronic band states in determining various physical properties.« less

  14. Student Response Systems and Learning: Perceptions of the Student.

    PubMed

    Benson, Jeryl D; Szucs, Kimberly A; Taylor, Meredith

    2016-10-01

    To assess student perception of learning and use of a student response system (SRS) as a teaching/learning strategy. Survey methods were used to explore student perceptions of learning and use of student response systems as a pedagogical strategy. Fifty-nine graduate students participated in the survey post completion of two graduate intervention courses. Overall, there was a positive response to the use of SRS's in the classroom. All of the students (100%) recommended the continued use of the clickers for various reasons. The primary benefit reported by students related to providing immediate feedback, the opportunity to manipulate and revisit the content, and the ability to check for understanding within a class session. Students recommended the continued use of the SRS in classes to support acquisition of content and exam preparation. The student reported technology difficulties as the only the negative to SRS use in the classroom. Instructor perception was that the addition of the SRS devices added a new way to interact with the students. Suggestions for incorporating the use of a SRS devices into classroom instruction are offered.

  15. Transabdominal wall deployment for instruments, lights, and micromotors using the concept of secured independent tools.

    PubMed

    Tsin, Daniel A; Davila, Fausto; Dominguez, Guillermo; Tinelli, Andrea; Davila, Martha R

    2012-05-01

    Use of secured independent tools (SIT) is changing the laparoscopy paradigm, which involves the use of instruments inside the abdominal cavity that are operated via a port that is larger in diameter than the instrument itself. However, in SIT instead of ports we used filaments or cables. Here we describe a modified SIT for use in the introduction of sutures or cables inside the peritoneum. Cables or sutures are passed through a tunnel made by an intravenous catheter and then exteriorized via a 12-mm port for tying, plugging (attaching), or connecting to different types of devices such as an endoscopic bulldog, alligator clamps, lights, and micromotors. These devices are introduced inside the abdomen and remotely operated with cables or filaments. The use of SIT is not limited to laparoscopy; it was successfully used in clinical experiences of single-port and single-incision laparoscopy and could facilitate natural orifice surgery. The technique offers a good force for traction, retraction, and mobilization. In addition, it has transmission capabilities for cameras and may facilitate the placement of wired microrobotics.

  16. A fast switch, combiner and narrow-band filter for high-power millimetre wave beams

    NASA Astrophysics Data System (ADS)

    Kasparek, W.; Petelin, M. I.; Shchegolkov, D. Yu; Erckmann, V.; Plaum, B.; Bruschi, A.; ECRH Groups at IPP Greifswald; Karlsruhe, FZK; Stuttgart, IPF

    2008-05-01

    A fast directional switch (FADIS) is described, which allows controlled switching of high-power microwaves between two outputs. A possible application could be synchronous stabilization of neoclassical tearing modes (NTMs). Generally, the device can be used to share the installed EC power between different types of launchers or different applications (e.g. in ITER, midplane/upper launcher). The switching is performed electronically without moving parts by a small frequency-shift keying of the gyrotron (some tens of megahertz), and a narrow-band diplexer. The device can be operated as a beam combiner also, which offers attractive transmission perspectives in multi-megawatt ECRH systems. In addition, these diplexers are useful for plasma diagnostic systems employing high-power sources due to their filter characteristics. The principle and the design of a four-port quasi-optical resonator diplexer is presented. Low-power measurements of switching contrast, mode purity and efficiency show good agreement with theory. Preliminary frequency modulation characteristics of gyrotrons are shown, and first results from high-power switching experiments using the ECRH system for W7-X are presented.

  17. Room-Temperature Creation and Spin–Orbit Torque Manipulation of Skyrmions in Thin Films with Engineered Asymmetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Guoqiang; Upadhyaya, Pramey; Li, Xiang

    2016-03-09

    Magnetic skyrmions, which are topologically protected spin textures, are promising candidates for ultralow-energy and ultrahigh-density magnetic data storage and computing applications. To date, most experiments on skyrmions have been carried out at low temperatures. The choice of available materials is limited, and there is a lack of electrical means to control skyrmions in devices. In this work, we demonstrate a new method for creating a stable skyrmion bubble phase in the CoFeB–MgO material system at room temperature, by engineering the interfacial perpendicular magnetic anisotropy of the ferromagnetic layer. Importantly, we also demonstrate that artificially engineered symmetry breaking gives rise tomore » a force acting on the skyrmions, in addition to the current-induced spin–orbit torque, which can be used to drive their motion. This room-temperature creation and manipulation of skyrmions offers new possibilities to engineer skyrmionic devices. The results bring skyrmionic memory and logic concepts closer to realization in industrially relevant and manufacturable thin film material systems.« less

  18. Room-Temperature Creation and Spin–Orbit Torque Manipulation of Skyrmions in Thin Films with Engineered Asymmetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Guoqiang; Upadhyaya, Pramey; Li, Xiang

    2016-02-10

    Magnetic skyrmions, which are topologically protected spin textures, are promising candidates for ultralow-energy and ultrahigh-density magnetic data storage and computing applications. To date, most experiments on skyrmions have been carried out at low temperatures. The choice of available materials is limited, and there is a lack of electrical means to control skyrmions in devices. In this work, we demonstrate a new method for creating a stable skyrmion bubble phase in the CoFeB–MgO material system at room temperature, by engineering the interfacial perpendicular magnetic anisotropy of the ferromagnetic layer. Importantly, we also demonstrate that artificially engineered symmetry breaking gives rise tomore » a force acting on the skyrmions, in addition to the current-induced spin–orbit torque, which can be used to drive their motion. This room-temperature creation and manipulation of skyrmions offers new possibilities to engineer skyrmionic devices. The results bring skyrmionic memory and logic concepts closer to realization in industrially relevant and manufacturable thin film material systems.« less

  19. An e-caring chair for physiological signal measurement and recording.

    PubMed

    Chang, Hsien-Tsung; Chung, Chyan-Goei; Chen, Ming-Wei

    2013-02-01

    There is an increasing awareness among the populace of the need for regular health check-up to detect diseases in their early stages and thereby administer treatments in a timely fashion. However, commercially available physiological signal monitoring devices, which may offer clues on the onset of diseases, are time-consuming, far from user friendly and limited in their applications. We design an e-caring chair that combines six modular physiological signal measurement instruments into a single unit, enabling users to simultaneously measure the blood pressure, body temperature, heart rate, height, weight and body fat percentage, and display the results and simple diagnoses in real time. The e-caring chair further allows for easy integration of additional physiological signal measuring devices, speedy measurements and long term monitoring of any trends that may emerge, making it easier for users to be alerted to physiological changes in the body without the need to enlist assistance from medical personnel. In this paper, we describe how this e-caring chair can be placed in several different environments for different purposes. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Different Perspectives on Technology Acceptance: The Role of Technology Type and Age

    NASA Astrophysics Data System (ADS)

    Arning, Katrin; Ziefle, Martina

    Although eHealth technologies offer an enormous potential to improve healthcare, the knowledge about key determinants of acceptance for eHealth technology is restricted. While the underlying technology of eHealth technologies and Information and Communication technology (ICT) is quite similar, utilization contexts and using motives are quite different. In order to explore the role of technology type on acceptance, we contrasted central application characteristics of both technology types using the scenario technique. A questionnaire was administered (n = 104) measuring individual variables (age, gender) and attitudes regarding an eHealth application (blood sugar meter) in contrast to an ICT device (Personal Digital Assistant, PDA). Older users basically approved the utilization of health-related technologies and perceived lower usability barriers. In addition, we identified main utilization motives of eHealth technology and technology-specific acceptance patterns, especially regarding issues of data safety in the eHealth context. Effects of age and gender in acceptance ratings suggest a differential perspective on eHealth acceptance. Finally, practical interventions were derived in order to support eHealth device design and to promote acceptance of eHealth technology.

  1. Virtual reality as a method for evaluation and therapy after traumatic hand surgery.

    PubMed

    Nica, Adriana Sarah; Brailescu, Consuela Monica; Scarlet, Rodica Gabriela

    2013-01-01

    In the last decade, Virtual Reality has encountered a continuous development concerning medical purposes and there are a lot of devices based on the classic "cyberglove" concept that are used as new therapeutic method for upper limb pathology, especially neurologic problems [1;2;3]. One of the VR devices is Pablo (Tyromotion), with very sensitive sensors that can measure the hand grip strenght and the pinch force, also the ROM (range of motion) for all the joints of the upper limb (shoulder, elbow, wrist) and offering the possibility of interactive games based on Virtual Reality concept with application in occupational therapy programs. We used Pablo in our study on patients with hand surgery as an objective tool for assessment and as additional therapeutic method to the classic Rehabilitation program [4;5]. The results of the study proved that Pablo represents a modern option for evaluation of hand deficits and dysfunctions, with objective measurement replacement of classic goniometry and dynamometry, with computerized data base of patients with monitoring of parameters during the recovery program and with better muscular and neuro-cognitive feedback during the interactive therapeutic modules.

  2. Highly efficient birefringent quarter-wave plate based on all-dielectric metasurface and graphene

    NASA Astrophysics Data System (ADS)

    Owiti, Edgar O.; Yang, Hanning; Liu, Peng; Ominde, Calvine F.; Sun, Xiudong

    2018-07-01

    All-dielectric metasurfaces offer remarkable properties including high efficiency and flexible control of the optical response. However, extreme, narrow bandwidth is a limitation that lowers applicability of these structures in photonic sensing applications. In this work, we numerically design and propose a switchable quarter-wave plate by hybridizing an all-dielectric metasurface with graphene. By using a single layer of graphene between a highly refractive index silicon and a silica substrate, the transmissive resonance is enhanced and broadened. Additionally, integrating graphene with silicon effectively modulates the Q-factor and the trapped magnetic modes in the silicon. A stable birefringence output is obtained and manipulated through the structure dimensions and the Fermi energy of graphene. A 95% polarization conversion ratio is achieved through converting linearly polarized light into circularly polarized light, and a 96% ellipticity ratio is obtained at the resonance wavelength. The structure is compact and has an ultrathin design thickness of 0 . 1 λ, in the telecommunication region. The above properties are essential for integration into photonic sensing devices and the structure has potential for compatibility with the CMOS devices.

  3. Active-matrix OLED using 150°C a-Si TFT backplane built on flexible plastic substrate

    NASA Astrophysics Data System (ADS)

    Sarma, Kalluri R.; Chanley, Charles; Dodd, Sonia R.; Roush, Jared; Schmidt, John; Srdanov, Gordana; Stevenson, Matthew; Wessel, Ralf; Innocenzo, Jeffrey; Yu, Gang; O'Regan, Marie B.; MacDonald, W. A.; Eveson, R.; Long, Ke; Gleskova, Helena; Wagner, Sigurd; Sturm, James C.

    2003-09-01

    Flexible displays fabricated using plastic substrates have a potential for being very thin, light weight, highly rugged with greatly minimized propensity for breakage, roll-to-roll manufacturing and lower cost. The emerging OLED display media offers the advantage of being a solid state and rugged structure for flexible displays in addition to the many potential advantages of an AM OLED over the currently dominant AM LCD. The current high level of interest in flexible displays is facilitating the development of the required enabling technologies which include development of plastic substrates, low temperature active matrix device and backplane fabrication, and display packaging. In the following we will first discuss our development efforts in the PEN based plastic substrates, active matrix backplane technology, low temperature (150°C) a-Si TFT devices and an AM OLED test chip used for evaluating various candidate designs. We will then describe the design, fabrication and successful evaluation and demonstration of a 64x64 pixel AM OLED test display using a-Si TFT backplane fabricated at 150°C on the flexible plastic substrate.

  4. Critical issues for the application of integrated MEMS/CMOS technologies to inertial measurement units

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, J.H.; Ellis, J.R.; Montague, S.

    1997-03-01

    One of the principal applications of monolithically integrated micromechanical/microelectronic systems has been accelerometers for automotive applications. As integrated MEMS/CMOS technologies such as those developed by U.C. Berkeley, Analog Devices, and Sandia National Laboratories mature, additional systems for more sensitive inertial measurements will enter the commercial marketplace. In this paper, the authors will examine key technology design rules which impact the performance and cost of inertial measurement devices manufactured in integrated MEMS/CMOS technologies. These design parameters include: (1) minimum MEMS feature size, (2) minimum CMOS feature size, (3) maximum MEMS linear dimension, (4) number of mechanical MEMS layers, (5) MEMS/CMOS spacing.more » In particular, the embedded approach to integration developed at Sandia will be examined in the context of these technology features. Presently, this technology offers MEMS feature sizes as small as 1 {micro}m, CMOS critical dimensions of 1.25 {micro}m, MEMS linear dimensions of 1,000 {micro}m, a single mechanical level of polysilicon, and a 100 {micro}m space between MEMS and CMOS. This is applicable to modern precision guided munitions.« less

  5. Facile synthesis of layered V2O5/ZnV2O6 heterostructures with enhanced sensing performance

    NASA Astrophysics Data System (ADS)

    Xiao, Bingxin; Huang, Hao; Yu, Xiantong; Song, Jun; Qu, Junle

    2018-07-01

    A low-cost and environment-friendly hydrothermal approach was used for the synthesis of layered V2O5/ZnV2O6 hybrid nanobelts. Characterization results indicate that the V2O5/ZnV2O6 nanobelts are composed of several thin layers. Additionally, it is illustrated that the chemical formation process of V2O5/ZnV2O6 occurred in the solution. The synthesized V2O5/ZnV2O6 heterostructures were subjected to detailed ethanol sensing tests. Results demonstrate that V2O5/ZnV2O6 based sensor shows about 4.3 of response to 100 ppm of ethanol gases, reveals relatively high sensitivity at relatively low optimal operating temperature of 240 °C, as well as relatively good selectivity and stability. The performance of the sensor is better than most of reported vanadium based sensing devices. Thus this work offers a new insight into the rational regulation of vanadium based sensing devices.

  6. Emerging Applications of Liquid Crystals Based on Nanotechnology

    PubMed Central

    Sohn, Jung Inn; Hong, Woong-Ki; Choi, Su Seok; Coles, Harry J.; Welland, Mark E.; Cha, Seung Nam; Kim, Jong Min

    2014-01-01

    Diverse functionalities of liquid crystals (LCs) offer enormous opportunities for their potential use in advanced mobile and smart displays, as well as novel non-display applications. Here, we present snapshots of the research carried out on emerging applications of LCs ranging from electronics to holography and self-powered systems. In addition, we will show our recent results focused on the development of new LC applications, such as programmable transistors, a transparent and active-type two-dimensional optical array and self-powered display systems based on LCs, and will briefly discuss their novel concepts and basic operating principles. Our research will give insights not only into comprehensively understanding technical and scientific applications of LCs, but also developing new discoveries of other LC-based devices. PMID:28788555

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aytug, Tolga; Simpson, John T.; Lupini, Andrew R.

    Inspired by highly non-wetting natural biological surfaces (e.g., lotus leaves and water strider legs), artificial superhydrophobic surfaces that exhibit water droplet contact angles exceeding 150o have previously been constructed by utilizing various synthesis strategies.[ , , ] Such bio-inspired, water-repellent surfaces offer significant potential for numerous uses ranging from marine applications (e.g., anti-biofouling, anti-corrosion), anti-condensation (e.g., anti-icing, anti-fogging), membranes for selective separation (e.g., oil-water, gas-liquid), microfluidic systems, surfaces requiring reduced maintenance and cleaning, to applications involving glasses and optical materials.[ ] In addition to superhydrophobic attributes, for integration into device systems that have extended operational limits and overall improved performance,more » surfaces that also possess multifunctional characteristics are desired, where the functionality should match to the application-specific requirements.« less

  8. Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm

    PubMed Central

    Dagdeviren, Canan; Yang, Byung Duk; Su, Yewang; Tran, Phat L.; Joe, Pauline; Anderson, Eric; Xia, Jing; Doraiswamy, Vijay; Dehdashti, Behrooz; Feng, Xue; Lu, Bingwei; Poston, Robert; Khalpey, Zain; Ghaffari, Roozbeh; Huang, Yonggang; Slepian, Marvin J.; Rogers, John A.

    2014-01-01

    Here, we report advanced materials and devices that enable high-efficiency mechanical-to-electrical energy conversion from the natural contractile and relaxation motions of the heart, lung, and diaphragm, demonstrated in several different animal models, each of which has organs with sizes that approach human scales. A cointegrated collection of such energy-harvesting elements with rectifiers and microbatteries provides an entire flexible system, capable of viable integration with the beating heart via medical sutures and operation with efficiencies of ∼2%. Additional experiments, computational models, and results in multilayer configurations capture the key behaviors, illuminate essential design aspects, and offer sufficient power outputs for operation of pacemakers, with or without battery assist. PMID:24449853

  9. Tunable plasmon-induced transparency with graphene-based T-shaped array metasurfaces

    NASA Astrophysics Data System (ADS)

    Niu, Yuying; Wang, Jicheng; Hu, Zhengda; Zhang, Feng

    2018-06-01

    The frequency tunable Plasmonic induced transparency (PIT) effect is researched with a periodically patterned T-shaped graphene array in mid-infrared region. We adjust the geometrical parameters to obtain the optimized combination for the realization of the PIT response and use the coupled Lorentz oscillator model to analysis the physical mechanism. Due to the properties of graphene, the PIT effect can be easily and markedly enhanced with the increase of chemical potential and carrier mobility. The frequency of PIT effect is also insensitive with the angle of incident light. In addition, we also propose the π shaped structure to realizing the double-peak PIT effect. The results offer a flexible approach for the development of tunable graphene-based photonic devices.

  10. Ultralight Weight Optical Systems Using Nano-Layered Synthesized Materials

    NASA Technical Reports Server (NTRS)

    Clark, Natalie; Breckinridge, James

    2014-01-01

    Optical imaging is important for many NASA science missions. Even though complex optical systems have advanced, the optics, based on conventional glass and mirrors, require components that are thick, heavy and expensive. As the need for higher performance expands, glass and mirrors are fast approaching the point where they will be too large, heavy and costly for spacecraft, especially small satellite systems. NASA Langley Research Center is developing a wide range of novel nano-layered synthesized materials that enable the development and fabrication of ultralight weight optical device systems that enable many NASA missions to collect science data imagery using small satellites. In addition to significantly reducing weight, the nano-layered synthesized materials offer advantages in performance, size, and cost.

  11. Inventing an Energy Internet: Concepts, Architectures and Protocols for Smart Energy Utilization

    ScienceCinema

    Tsoukalas, Lefteri

    2018-01-24

    In recent years, the Internet is revolutionizing information availability much like the Power Grid revolutionized energy availability a century earlier. We will explore the differences and similarities of these two critical infrastructures and identify ways for convergence which may lead to an energy internet. Pricing signals, nodal forecasting, and short-term elasticities are key concepts in smart energy flows respecting the delicate equilibrium involved in generation-demand and aiming at higher efficiencies. We will discuss how intelligent forecasting approaches operating at multiple levels (including device or nodal levels) can ameliorate the challenges of power storage. In addition to higher efficiencies, an energy internet may achieve significant reliability and security improvements and offer greater flexibility and transparency in the overall energy-environmental relation.

  12. Peptide nanostructures in biomedical technology.

    PubMed

    Feyzizarnagh, Hamid; Yoon, Do-Young; Goltz, Mark; Kim, Dong-Shik

    2016-09-01

    Nanostructures of peptides have been investigated for biomedical applications due to their unique mechanical and electrical properties in addition to their excellent biocompatibility. Peptides may form fibrils, spheres and tubes in nanoscale depending on the formation conditions. These peptide nanostructures can be used in electrical, medical, dental, and environmental applications. Applications of these nanostructures include, but are not limited to, electronic devices, biosensing, medical imaging and diagnosis, drug delivery, tissue engineering and stem cell research. This review offers a discussion of basic synthesis methods, properties and application of these nanomaterials. The review concludes with recommendations and future directions for peptide nanostructures. WIREs Nanomed Nanobiotechnol 2016, 8:730-743. doi: 10.1002/wnan.1393 For further resources related to this article, please visit the WIREs website. © 2016 Wiley Periodicals, Inc.

  13. Mitral Transcatheter Technologies

    PubMed Central

    Maisano, Francesco; Buzzatti, Nicola; Taramasso, Maurizio; Alfieri, Ottavio

    2013-01-01

    Mitral valve regurgitation (MR) is often diagnosed in patients with heart failure and is associated with worsening of symptoms and reduced survival. While surgery remains the gold standard treatment in low-risk patients with degenerative MR, in high-risk patients and in those with functional MR, transcatheter procedures are emerging as an alternative therapeutic option. MitraClip® is the device with which the largest clinical experience has been gained to date, as it offers sustained clinical benefit in selected patients. Further to MitraClip implantation, several additional approaches are developing, to better match with the extreme variability of mitral valve disease. Not only repair is evolving, initial steps towards percutaneous mitral valve implantation have already been undertaken, and initial clinical experience has just started. PMID:23908865

  14. Storage Reliability of Missile Materiel Program. Storage Reliability Analysis Summary Report. Volume 1. Electrical and Electronic Devices

    DTIC Science & Technology

    1976-05-01

    since the platinum silicide and titanium metals also offer very low mobility to the alkaline ions, the BLSJ . is inert to sodium . Inversion and...gettering agents for sodium ions, thus making the cont&-nination far less mobile. The stability of the structural and electrical properties of the oxide...to be an effective barrier to sodium migration. In Beam Lead Sealed ,unction (BLSJ) devices, the silicon nitride seals the devices from sodium and

  15. From One to Many Boxes: Mobile Devices as Primary and Secondary Screens

    NASA Astrophysics Data System (ADS)

    Cesar, Pablo; Knoche, Hendrik; Bulterman, Dick C. A.

    This chapter looks at the current changing habits on audiovisual content consumption at home, with special focus on potential uses of mobile devices. Standard television plus a remote control impose a use that is too coarse to support the various personal needs of people, while mobile devices open new possibilities from engagement and immersion into content and deliberately controlled disengagement with others to providing a screen that can be offered to include others in sharing experiences in a huddled setting.

  16. Open-source hardware for medical devices

    PubMed Central

    2016-01-01

    Open-source hardware is hardware whose design is made publicly available so anyone can study, modify, distribute, make and sell the design or the hardware based on that design. Some open-source hardware projects can potentially be used as active medical devices. The open-source approach offers a unique combination of advantages, including reducing costs and faster innovation. This article compares 10 of open-source healthcare projects in terms of how easy it is to obtain the required components and build the device. PMID:27158528

  17. Electric control of superconducting transition through a spin-orbit coupled interface

    PubMed Central

    Ouassou, Jabir Ali; Di Bernardo, Angelo; Robinson, Jason W. A.; Linder, Jacob

    2016-01-01

    We demonstrate theoretically all-electric control of the superconducting transition temperature using a device comprised of a conventional superconductor, a ferromagnetic insulator, and semiconducting layers with intrinsic spin-orbit coupling. By using analytical calculations and numerical simulations, we show that the transition temperature of such a device can be controlled by electric gating which alters the ratio of Rashba to Dresselhaus spin-orbit coupling. The results offer a new pathway to control superconductivity in spintronic devices. PMID:27426887

  18. Open-source hardware for medical devices.

    PubMed

    Niezen, Gerrit; Eslambolchilar, Parisa; Thimbleby, Harold

    2016-04-01

    Open-source hardware is hardware whose design is made publicly available so anyone can study, modify, distribute, make and sell the design or the hardware based on that design. Some open-source hardware projects can potentially be used as active medical devices. The open-source approach offers a unique combination of advantages, including reducing costs and faster innovation. This article compares 10 of open-source healthcare projects in terms of how easy it is to obtain the required components and build the device.

  19. Determination of plasma displacement based on eddy current diagnostics for the Keda Torus eXperiment

    NASA Astrophysics Data System (ADS)

    Tu, Cui; Li, Hong; Liu, Adi; Li, Zichao; Zhang, Yuan; You, Wei; Tan, Mingsheng; Luo, Bing; Adil, Yolbarsop; Hu, Jintong; Wu, Yanqi; Yan, Wentan; Xie, Jinlin; Lan, Tao; Mao, Wenzhe; Ding, Weixing; Xiao, Chijin; Zhuang, Ge; Liu, Wandong

    2017-10-01

    The measurement of plasma displacement is one of the most basic diagnostic tools in the study of plasma equilibrium and control in a toroidal magnetic confinement configuration. During pulse discharge, the eddy current induced in the vacuum vessel and shell will produce an additional magnetic field at the plasma boundary, which will have a significant impact on the measurement of plasma displacement using magnetic probes. In the newly built Keda Torus eXperiment (KTX) reversed field pinch device, the eddy current in the composite shell can be obtained at a high spatial resolution. This device offers a new way to determine the plasma displacement for KTX through the multipole moment expansion of the eddy current, which can be obtained by unique probe arrays installed on the inner and outer surfaces of the composite shell. In an ideal conductor shell approximation, the method of multipole moment expansion of the poloidal eddy current for measuring the plasma displacement in toroidal coordinates, is more accurate than the previous method based on symmetrical magnetic probes, which yielded results in cylindrical coordinates. Through an analytical analysis of many current filaments and numerical simulations of the current distribution in toroidal coordinates, the scaling relation between the first moment of the eddy current and the center of gravity of the plasma current is obtained. In addition, the origin of the multipole moment expansion of the eddy current in KTX is retrieved simultaneously. Preliminary data on the plasma displacement have been collected using these two methods during short pulse discharges in the KTX device, and the results of the two methods are in reasonable agreement.

  20. Fiber pressure sensors based on periodical mode coupling effects

    NASA Astrophysics Data System (ADS)

    Lotem, Haim; Wang, Wen C.; Wang, Michael; Schaafsma, David; Skolnick, Bob; Grebel, Haim

    2005-05-01

    Fiber optic sensor technology offers the possibility of implementing low weight, high performance and cost effective health and damage assessment for infrastructure elements. Common fiber sensors are based on the effect of external action on the spectral response of a Fabry-Perot or a Bragg grating section, or on the modal dynamics in multimode (MM) fiber. In the latter case, the fiber itself acts as the sensor, giving it the potential for large range coverage. We were interested in this type of sensor because of its cost advantage in monitoring structural health. In the course of the research, a new type of a rugged modal filter device, based on off-center splicing, was developed. This device, in combination with a MM fiber, was found to be a potential single point-pressure sensing device. Additionally, by translating the pressing point along a MM sensing fiber with a constant load and speed, a sinusoidal intensity modulation was observed. This harmonic behavior, during load translation, is explained by the theory of mode coupling and dispersion. The oscillation period, L~0.43. mm, obtained at 980 nm in a Corning SMF-28 fiber, corresponds to the wavevector difference, Db, between the two-coupled modes, by L = 2p/Db. An additional outcome of the present research is the observation that the response of the loaded MM fiber is strongly dependent on the polarization state of the light traveling along the MM fiber due to different response of the modes to polarization active elements. Our main conclusions are that in MM fiber optic sensor design, special cautions need to be taken in order to stabilize the system, and that the sensitivity along a MM fiber sensor is periodic with a period of ~ 0.4 - 0.5 mm, depending on various fiber parameters and excited modes.

  1. A simple miniature device for wireless stimulation of neural circuits in small behaving animals.

    PubMed

    Zhang, Yisi; Langford, Bruce; Kozhevnikov, Alexay

    2011-10-30

    The use of wireless neural stimulation devices offers significant advantages for neural stimulation experiments in behaving animals. We demonstrate a simple, low-cost and extremely lightweight wireless neural stimulation device which is made from off-the-shelf components. The device has low power consumption and does not require a high-power RF preamplifier. Neural stimulation can be carried out in either a voltage source mode or a current source mode. Using the device, we carry out wireless stimulation in the premotor brain area HVC of a songbird and demonstrate that such stimulation causes rapid perturbations of the acoustic structure of the song. Published by Elsevier B.V.

  2. Reconfigurable optomechanical circulator and directional amplifier.

    PubMed

    Shen, Zhen; Zhang, Yan-Lei; Chen, Yuan; Sun, Fang-Wen; Zou, Xu-Bo; Guo, Guang-Can; Zou, Chang-Ling; Dong, Chun-Hua

    2018-05-04

    Non-reciprocal devices, which allow non-reciprocal signal routing, serve as fundamental elements in photonic and microwave circuits and are crucial in both classical and quantum information processing. The radiation-pressure-induced coupling between light and mechanical motion in travelling-wave resonators has been exploited to break the Lorentz reciprocity, enabling non-reciprocal devices without magnetic materials. Here, we experimentally demonstrate a reconfigurable non-reciprocal device with alternative functions as either a circulator or a directional amplifier via optomechanically induced coherent photon-phonon conversion or gain. The demonstrated device exhibits considerable flexibility and offers exciting opportunities for combining reconfigurability, non-reciprocity and active properties in single photonic devices, which can also be generalized to microwave and acoustic circuits.

  3. Ability of walking without a walking device in patients with spinal cord injury as determined using data from functional tests

    PubMed Central

    Poncumhak, Puttipong; Saengsuwan, Jiamjit; Amatachaya, Sugalya

    2014-01-01

    Background/Objectives More than half of independent ambulatory patients with spinal cord injury (SCI) need a walking device to promote levels of independence. However, long-lasting use of a walking device may introduce negative impacts for the patients. Using a standard objective test relating to the requirement of a walking device may offer a quantitative criterion to effectively monitor levels of independence of the patients. Therefore, this study investigated (1) ability of the three functional tests, including the five times sit-to-stand test (FTSST), timed up and go test (TUGT), and 10-meter walk test (10MWT) to determine the ability of walking without a walking device, and (2) the inter-tester reliability of the tests to assess functional ability in patients with SCI. Methods Sixty independent ambulatory patients with SCI, who walked with and without a walking device (30 subjects/group), were assessed cross-sectionally for their functional ability using the three tests. The first 20 subjects also participated in the inter-tester reliability test. Results The time required to complete the FTSST <14 seconds, the TUGT < 18 seconds, and the 10MWT < 6 seconds had good-to-excellent capability to determine the ability of walking without a walking device of subjects with SCI. These tests also showed excellent inter-tester reliability. Conclusions Methods of clinical evaluation for walking are likely performed using qualitative observation, which makes the results difficult to compare among testers and test intervals. Findings of this study offer a quantitative target criterion or a clear level of ability that patients with SCI could possibly walk without a walking device, which would benefit monitoring process for the patients. PMID:24621030

  4. Boron nitride nanotubes for spintronics.

    PubMed

    Dhungana, Kamal B; Pati, Ranjit

    2014-09-22

    With the end of Moore's law in sight, researchers are in search of an alternative approach to manipulate information. Spintronics or spin-based electronics, which uses the spin state of electrons to store, process and communicate information, offers exciting opportunities to sustain the current growth in the information industry. For example, the discovery of the giant magneto resistance (GMR) effect, which provides the foundation behind modern high density data storage devices, is an important success story of spintronics; GMR-based sensors have wide applications, ranging from automotive industry to biology. In recent years, with the tremendous progress in nanotechnology, spintronics has crossed the boundary of conventional, all metallic, solid state multi-layered structures to reach a new frontier, where nanostructures provide a pathway for the spin-carriers. Different materials such as organic and inorganic nanostructures are explored for possible applications in spintronics. In this short review, we focus on the boron nitride nanotube (BNNT), which has recently been explored for possible applications in spintronics. Unlike many organic materials, BNNTs offer higher thermal stability and higher resistance to oxidation. It has been reported that the metal-free fluorinated BNNT exhibits long range ferromagnetic spin ordering, which is stable at a temperature much higher than room temperature. Due to their large band gap, BNNTs are also explored as a tunnel magneto resistance device. In addition, the F-BNNT has recently been predicted as an ideal spin-filter. The purpose of this review is to highlight these recent progresses so that a concerted effort by both experimentalists and theorists can be carried out in the future to realize the true potential of BNNT-based spintronics.

  5. Ultra-Low Loss Waveguides with Application to Photonic Integrated Circuits

    NASA Astrophysics Data System (ADS)

    Bauters, Jared F.

    The integration of photonic components using a planar platform promises advantages in cost, size, weight, and power consumption for optoelectronic systems. Yet, the typical propagation loss of 5-10 dB/m in a planar silica waveguide is nearly five orders-of-magnitude larger than that in low loss optical fibers. For some applications, the miniaturization of the photonic system and resulting smaller propagation lengths from integration are enough to overcome the increase in propagation loss. For other more demanding systems or applications, such as those requiring long optical time delays or high-quality-factor (Q factor) resonators, the high propagation loss can degrade system performance to a degree that trumps the potential advantages offered by integration. Thus, the reduction of planar waveguide propagation loss in a Si3-N4 based waveguide platform is a primary focus of this dissertation. The ultra-low loss stoichiometric Si3-N4 waveguide platform offers the additional advantages of fabrication process stability and repeatability. Yet, active devices such as lasers, amplifiers, and photodetectors have not been monolithically integrated with ultra-low loss waveguides due to the incompatibility of the active and ultra-low loss processing thermal budgets (ultra-low loss waveguides are annealed at temperatures exceeding 1000 °C in order to drive out impurities). So a platform that enables the integration of active devices with the ultra-low losses of the Si3- N4 waveguide platform is this dissertation's second focus. The work enables the future fabrication of sensor, gyroscope, true time delay, and low phase noise oscillator photonic integrated circuits.

  6. Boron Nitride Nanotubes for Spintronics

    PubMed Central

    Dhungana, Kamal B.; Pati, Ranjit

    2014-01-01

    With the end of Moore's law in sight, researchers are in search of an alternative approach to manipulate information. Spintronics or spin-based electronics, which uses the spin state of electrons to store, process and communicate information, offers exciting opportunities to sustain the current growth in the information industry. For example, the discovery of the giant magneto resistance (GMR) effect, which provides the foundation behind modern high density data storage devices, is an important success story of spintronics; GMR-based sensors have wide applications, ranging from automotive industry to biology. In recent years, with the tremendous progress in nanotechnology, spintronics has crossed the boundary of conventional, all metallic, solid state multi-layered structures to reach a new frontier, where nanostructures provide a pathway for the spin-carriers. Different materials such as organic and inorganic nanostructures are explored for possible applications in spintronics. In this short review, we focus on the boron nitride nanotube (BNNT), which has recently been explored for possible applications in spintronics. Unlike many organic materials, BNNTs offer higher thermal stability and higher resistance to oxidation. It has been reported that the metal-free fluorinated BNNT exhibits long range ferromagnetic spin ordering, which is stable at a temperature much higher than room temperature. Due to their large band gap, BNNTs are also explored as a tunnel magneto resistance device. In addition, the F-BNNT has recently been predicted as an ideal spin-filter. The purpose of this review is to highlight these recent progresses so that a concerted effort by both experimentalists and theorists can be carried out in the future to realize the true potential of BNNT-based spintronics. PMID:25248070

  7. Novel Low-Cost, Low-Power Miniature Thermionic Cathode Developed for Microwave/Millimeter Wave Tube and Cathode Ray Tube Applications

    NASA Technical Reports Server (NTRS)

    Wintucky, Edwin G.

    1999-01-01

    A low cost, small size and mass, low heater power, durable high-performance barium dispenser thermionic cathode has been developed that offers significant advancements in the design, manufacture, and performance of the electron sources used in vacuum electronic devices--such as microwave (and millimeter wave) traveling-wave tubes (TWT's)--and in display devices such as high-brightness, high-resolution cathode ray tubes (CRT's). The lower cathode heater power and the reduced size and mass of the new cathode are expected to be especially beneficial in TWT's for deep space communications, where future missions are requiring smaller spacecraft, higher data transfer rates (higher frequencies and radiofrequency output power), and greater electrical efficiency. Also expected to benefit are TWT's for commercial and government communication satellites, for both low and geosynchronous Earth orbit, with additional benefits offered by lower cost and potentially higher cathode current loading. A particularly important TWT application is in the microwave power module (MPM), which is a hybrid microwave (or millimeter wave) amplifier consisting of a low-noise solid state driver, a vacuum power booster (small TWT), and an electronic power conditioner integrated into a single compact package. The attributes of compactness and potentially high electrical efficiency make the MPM very attractive for many commercial and government (civilian and defense) applications in communication and radar systems. The MPM is already finding application in defense electronic systems and is under development by NASA for deep space communications. However, for the MPM to become competitive and commercially successful, a major reduction in cost must be achieved.

  8. 3D Printed Bionic Nanodevices.

    PubMed

    Kong, Yong Lin; Gupta, Maneesh K; Johnson, Blake N; McAlpine, Michael C

    2016-06-01

    The ability to three-dimensionally interweave biological and functional materials could enable the creation of bionic devices possessing unique and compelling geometries, properties, and functionalities. Indeed, interfacing high performance active devices with biology could impact a variety of fields, including regenerative bioelectronic medicines, smart prosthetics, medical robotics, and human-machine interfaces. Biology, from the molecular scale of DNA and proteins, to the macroscopic scale of tissues and organs, is three-dimensional, often soft and stretchable, and temperature sensitive. This renders most biological platforms incompatible with the fabrication and materials processing methods that have been developed and optimized for functional electronics, which are typically planar, rigid and brittle. A number of strategies have been developed to overcome these dichotomies. One particularly novel approach is the use of extrusion-based multi-material 3D printing, which is an additive manufacturing technology that offers a freeform fabrication strategy. This approach addresses the dichotomies presented above by (1) using 3D printing and imaging for customized, hierarchical, and interwoven device architectures; (2) employing nanotechnology as an enabling route for introducing high performance materials, with the potential for exhibiting properties not found in the bulk; and (3) 3D printing a range of soft and nanoscale materials to enable the integration of a diverse palette of high quality functional nanomaterials with biology. Further, 3D printing is a multi-scale platform, allowing for the incorporation of functional nanoscale inks, the printing of microscale features, and ultimately the creation of macroscale devices. This blending of 3D printing, novel nanomaterial properties, and 'living' platforms may enable next-generation bionic systems. In this review, we highlight this synergistic integration of the unique properties of nanomaterials with the versatility of extrusion-based 3D printing technologies to interweave nanomaterials and fabricate novel bionic devices.

  9. 3D Printed Bionic Nanodevices

    PubMed Central

    Kong, Yong Lin; Gupta, Maneesh K.; Johnson, Blake N.; McAlpine, Michael C.

    2016-01-01

    Summary The ability to three-dimensionally interweave biological and functional materials could enable the creation of bionic devices possessing unique and compelling geometries, properties, and functionalities. Indeed, interfacing high performance active devices with biology could impact a variety of fields, including regenerative bioelectronic medicines, smart prosthetics, medical robotics, and human-machine interfaces. Biology, from the molecular scale of DNA and proteins, to the macroscopic scale of tissues and organs, is three-dimensional, often soft and stretchable, and temperature sensitive. This renders most biological platforms incompatible with the fabrication and materials processing methods that have been developed and optimized for functional electronics, which are typically planar, rigid and brittle. A number of strategies have been developed to overcome these dichotomies. One particularly novel approach is the use of extrusion-based multi-material 3D printing, which is an additive manufacturing technology that offers a freeform fabrication strategy. This approach addresses the dichotomies presented above by (1) using 3D printing and imaging for customized, hierarchical, and interwoven device architectures; (2) employing nanotechnology as an enabling route for introducing high performance materials, with the potential for exhibiting properties not found in the bulk; and (3) 3D printing a range of soft and nanoscale materials to enable the integration of a diverse palette of high quality functional nanomaterials with biology. Further, 3D printing is a multi-scale platform, allowing for the incorporation of functional nanoscale inks, the printing of microscale features, and ultimately the creation of macroscale devices. This blending of 3D printing, novel nanomaterial properties, and ‘living’ platforms may enable next-generation bionic systems. In this review, we highlight this synergistic integration of the unique properties of nanomaterials with the versatility of extrusion-based 3D printing technologies to interweave nanomaterials and fabricate novel bionic devices. PMID:27617026

  10. Infrared negative luminescent devices and higher operating temperature detectors

    NASA Astrophysics Data System (ADS)

    Nash, G. R.; Gordon, N. T.; Hall, D. J.; Ashby, M. K.; Little, J. C.; Masterton, G.; Hails, J. E.; Giess, J.; Haworth, L.; Emeny, M. T.; Ashley, T.

    2004-01-01

    Infrared LEDs and negative luminescent devices, where less light is emitted than in equilibrium, have been attracting an increasing amount of interest recently. They have a variety of applications, including as a ‘source’ of IR radiation for gas sensing; radiation shielding for, and non-uniformity correction of, high sensitivity staring infrared detectors; and dynamic infrared scene projection. Similarly, infrared (IR) detectors are used in arrays for thermal imaging and, discretely, in applications such as gas sensing. Multi-layer heterostructure epitaxy enables the growth of both types of device using designs in which the electronic processes can be precisely controlled and techniques such as carrier exclusion and extraction can be implemented. This enables detectors to be made which offer good performance at higher than normal operating temperatures, and efficient negative luminescent devices to be made which simulate a range of effective temperatures whilst operating uncooled. In both cases, however, additional performance benefits can be achieved by integrating optical concentrators around the diodes to reduce the volume of semiconductor material, and so minimise the thermally activated generation-recombination processes which compete with radiative mechanisms. The integrated concentrators are in the form of Winston cones, which can be formed using an iterative dry etch process involving methane/hydrogen and oxygen. We present results on negative luminescence in the mid- and long-IR wavebands, from devices made from indium antimonide and mercury cadmium telluride, where the aim is sizes greater than 1 cm×1 cm. We also discuss progress on, and the potential for, operating temperature and/or sensitivity improvement of detectors, where very high-performance imaging is anticipated from systems which require no mechanical cooling.

  11. Infrared negative luminescent devices and higher operating temperature detectors

    NASA Astrophysics Data System (ADS)

    Nash, Geoff R.; Gordon, Neil T.; Hall, David J.; Little, J. Chris; Masterton, G.; Hails, J. E.; Giess, J.; Haworth, L.; Emeny, Martin T.; Ashley, Tim

    2004-02-01

    Infrared LEDs and negative luminescent devices, where less light is emitted than in equilibrium, have been attracting an increasing amount of interest recently. They have a variety of applications, including as a ‘source" of IR radiation for gas sensing; radiation shielding for and non-uniformity correction of high sensitivity starring infrared detectors; and dynamic infrared scene projection. Similarly, IR detectors are used in arrays for thermal imaging and, discretely, in applications such as gas sensing. Multi-layer heterostructure epitaxy enables the growth of both types of device using designs in which the electronic processes can be precisely controlled and techniques such as carrier exclusion and extraction can be implemented. This enables detectors to be made which offer good performance at higher than normal operating temperatures, and efficient negative luminescent devices to be made which simulate a range of effective temperatures whilst operating uncooled. In both cases, however, additional performance benefits can be achieved by integrating optical concentrators around the diodes to reduce the volume of semiconductor material, and so minimise the thermally activated generation-recombination processes which compete with radiative mechanisms. The integrated concentrators are in the form of Winston cones, which can be formed using an iterative dry etch process involving methane/hydrogen and oxygen. We will present results on negative luminescence in the mid and long IR wavebands, from devices made from indium antimonide and mercury cadmium telluride, where the aim is sizes greater than 1cm x 1cm. We will also discuss progress on, and the potential for, operating temperature and/or sensitivity improvement of detectors, where very higher performance imaging is anticipated from systems which require no mechanical cooling.

  12. Infrared Negative Luminescent Devices and Higher Operating Temperature Detectors

    NASA Astrophysics Data System (ADS)

    Ashley, Tim

    2003-03-01

    Infrared LEDs and negative luminescent devices, where less light is emitted than in equilibrium, have been attracting an increasing amount of interest recently. They have a variety of applications, including as a source' of IR radiation for gas sensing; radiation shielding for and non-uniformity correction of high sensitivity starring infrared detectors; and dynamic infrared scene projection. Similarly, IR detectors are used in arrays for thermal imaging and, discretely, in applications such as gas sensing. Multi-layer heterostructure epitaxy enables the growth of both types of device using designs in which the electronic processes can be precisely controlled and techniques such as carrier exclusion and extraction can be implemented. This enables detectors to be made which offer good performance at higher than normal operating temperatures, and efficient negative luminescent devices to be made which simulate a range of effective temperatures whilst operating uncooled. In both cases, however, additional performance benefits can be achieved by integrating optical concentrators around the diodes to reduce the volume of semiconductor material, and so minimise the thermally activated generation-recombination processes which compete with radiative mechanisms. The integrated concentrators are in the form of Winston cones, which can be formed using an iterative dry etch process involving methane/hydrogen and oxygen. We will present results on negative luminescence in the mid and long IR wavebands, from devices made from indium antimonide and mercury cadmium telluride, where the aim is sizes greater than 1cm x 1cm. We will also discuss progress on, and the potential for, operating temperature and/or sensitivity improvement of detectors, where very high performance imaging is anticipated from systems which require no mechanical cooling.

  13. Validity of field expedient devices to assess core temperature during exercise in the cold.

    PubMed

    Bagley, James R; Judelson, Daniel A; Spiering, Barry A; Beam, William C; Bartolini, J Albert; Washburn, Brian V; Carney, Keven R; Muñoz, Colleen X; Yeargin, Susan W; Casa, Douglas J

    2011-12-01

    Exposure to cold environments affects human performance and physiological function. Major medical organizations recommend rectal temperature (TREC) to evaluate core body temperature (TcORE) during exercise in the cold; however, other field expedient devices claim to measure TCORE. The purpose of this study was to determine if field expedient devices provide valid measures of TcRE during rest and exercise in the cold. Participants included 13 men and 12 women (age = 24 +/- 3 yr, height = 170.7 +/- 10.6 cm, mass = 73.4 +/- 16.7 kg, body fat = 18 +/- 7%) who reported being healthy and at least recreationally active. During 150 min of cold exposure, subjects sequentially rested for 30 min, cycled for 90 min (heart rate = 120-140 bpm), and rested for an additional 30 min. Investigators compared aural (T(AUR)), expensive axillary (T(AXLe)), inexpensive axillary (T(AXLi)), forehead (T(FOR)), gastrointestinal (T(GI)), expensive oral (T(ORLe)), inexpensive oral (T(ORLi)), and temporal (T(TEM)) temperatures to T(REc) every 15 min. Researchers used mean difference between each device and T(REC) (i.e., mean bias) as the primary criterion for validity. T(AUR), T(AXLe), T(AXLi), T(FOR), TORLe, T(ORLi), and TTEM provided significantly lower measures compared to T(REC) and fell below our validity criterion. T(GI) significantly exceeded T(REC) at three of eleven time points, but no significant difference existed between mean T(REC) and T(GI) across time. Only T(GI) achieved our validity criterion and compared favorably to T(REC). T(GI) offers a valid measurement with which to assess T(CORE) during rest and exercise in the cold; athletic trainers, mountain rescuers, and military medical personnel should avoid other field expedient devices in similar conditions.

  14. Low Insertion Loss and Highly Sensitive SH-SAW Sensors Based on 36° YX LiTaO 3 Through the Incorporation of Filled Microcavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, Mandek; Sankaranarayanan, Subramanian K. R. S.; Bhethanabotla, Venkat R.

    2015-02-01

    Reduction in power consumption and improvement in mass sensitivity are important considerations for surface acoustic wave (SAW) devices used in various sensing applications. Detection of minute quantities of a particular species (clinical sensing) and power requirements (wireless sensing) are two key metrics that must be optimized. In this paper, a 3-D finite element model (FEM) was employed to compare insertion loss (IL) and mass sensitivity of SAW sensors having microcavities filled with ZnO and nanocrystalline diamond to a standard two-port SAW design. Initial simulation results show that ZnO filled cavities (depth = 5 mu m) were most effective at reducingmore » power loss Delta IL = (6.03 dB) by increasing particle displacement (acousto-electric to mechanical transduction) at the output transducer. A 100-pg/cm(2) load was applied to the sensing area of each device to evaluate mass sensitivity. Our simulations suggest that ZnO filled cavities with shallow depth (2.5 mu m) have the greatest sensitivity. The FEM simulations are used to understand the acoustic wave propagation in microcavity-based SAW sensors. The observed enhancement in mass sensitivity and power transfer is attributed to waveguiding effects and constructive interference of the scattered acoustic waves from the microcavities. Devices fabricated with microcavities similar to 1 mu m deep decreased IL by 3.306 dB compared with a standard SAW device. Additional simulations were conducted for each device configuration using the same depth in order to make a direct comparison between measured and simulated results. Our findings offer encouraging prospects for designing low IL highly sensitive microcavity-based SAW biosensors.« less

  15. Apparatus to collect, classify, concentrate, and characterize gas-borne particles

    DOEpatents

    Rader, Daniel J.; Torczynski, John R.; Wally, Karl; Brockmann, John E.

    2002-01-01

    An aerosol lab-on-a-chip (ALOC) integrates one or more of a variety of aerosol collection, classification, concentration (enrichment), and characterization processes onto a single substrate or layered stack of such substrates. By taking advantage of modern micro-machining capabilities, an entire suite of discrete laboratory aerosol handling and characterization techniques can be combined in a single portable device that can provide a wealth of data on the aerosol being sampled. The ALOC offers parallel characterization techniques and close proximity of the various characterization modules helps ensure that the same aerosol is available to all devices (dramatically reducing sampling and transport errors). Micro-machine fabrication of the ALOC significantly reduces unit costs relative to existing technology, and enables the fabrication of small, portable ALOC devices, as well as the potential for rugged design to allow operation in harsh environments. Miniaturization also offers the potential of working with smaller particle sizes and lower pressure drops (leading to reduction of power consumption).

  16. A DISCUSSION ON UTILIZATION OF HEAT PIPE AND VAPOUR CHAMBER TECHNOLOGY AS A PRIMARY DEVICE FOR HEAT EXTRACTION FROM PHOTON ABSORBER SURFACES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suthar, K. J.; Lurie, Alexander M.; Den Hartog, P.

    Heat pipes and vapour chambers work on heat exchange phenomena of two-phase flow and are widely used for in-dustrial and commercial applications. These devices offer very high effective thermal conductivities (5,000-200,000 W/m/K) and are adaptable to various sizes, shapes, and ori-entations. Although they have been found to be an excel-lent thermal management solution for laptops, satellites, and many things in-between, heat pipes and vapour cham-bers have yet to be adopted for use at particle accelerator facilities where they offer the possibility of more compact and more efficient means to remove heat from unwanted synchrotron radiation. As with all technologies, theremore » are inherent limitations. Foremost, they are limited by practi-cality to serve as local heat transfer devices; heat transfer over long distances is likely best provided by other means. Heat pipes also introduce unique failure modes which must be considered.« less

  17. Nanowire Chemical/Biological Sensors: Status and a Roadmap for the Future.

    PubMed

    Fennell, John F; Liu, Sophie F; Azzarelli, Joseph M; Weis, Jonathan G; Rochat, Sébastien; Mirica, Katherine A; Ravnsbæk, Jens B; Swager, Timothy M

    2016-01-22

    Chemiresistive sensors are becoming increasingly important as they offer an inexpensive option to conventional analytical instrumentation, they can be readily integrated into electronic devices, and they have low power requirements. Nanowires (NWs) are a major theme in chemosensor development. High surface area, interwire junctions, and restricted conduction pathways give intrinsically high sensitivity and new mechanisms to transduce the binding or action of analytes. This Review details the status of NW chemosensors with selected examples from the literature. We begin by proposing a principle for understanding electrical transport and transduction mechanisms in NW sensors. Next, we offer the reader a review of device performance parameters. Then, we consider the different NW types followed by a summary of NW assembly and different device platform architectures. Subsequently, we discuss NW functionalization strategies. Finally, we propose future developments in NW sensing to address selectivity, sensor drift, sensitivity, response analysis, and emerging applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Mobile Device Intervention for Student Support Services in Distance Education Context--FRAME Model Perspective

    ERIC Educational Resources Information Center

    Kumar, Lalita S.; Jamatia, Biplab; Aggarwal, A. K.; Kannan, S.

    2011-01-01

    This paper reports the findings of a study conducted to analyse the effect of mobile device intervention for student support services and to gauge its use for enhancing teaching--learning process as a future study in the context of offer of Distance Education programmes. The study was conducted with the learners of the coveted Post Graduate…

  19. 40 CFR 1068.101 - What general actions does this regulation prohibit?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... knowingly remove or render inoperative any such device or element of design after such sale and delivery to... controls by someone other than a manufacturer or dealer § 1068.101(b)(2) Sale or use of a defeat device 42... and D of this part: (1) Introduction into commerce. You may not sell, offer for sale, or introduce or...

  20. Less Is More: How to App-ify Your Library Services

    ERIC Educational Resources Information Center

    Williams, Berika S.

    2012-01-01

    How will your library serve mobile device users? By building apps from scratch? By offering entirely separate content? Or by modifying your site for mobile devices? This author found that the best fit for a joint library serving Victoria College and the University of Houston-Victoria was to build a mobile website in HTML and CSS using mobile…

  1. Digital Readers: The Next Chapter in E-Book Reading and Response

    ERIC Educational Resources Information Center

    Larson, Lotta C.

    2010-01-01

    The basic features of digital reading devices (such as the Amazon Kindle) are described in this article. The author also considers how such devices can advance e-book readership among primary students by offering new avenues for accessing and interacting with a wide array of texts. Rooted in the transactional theory of reader response and a new…

  2. SNS Heterojunctions With New Combinations Of Materials

    NASA Technical Reports Server (NTRS)

    Vasquez, Richard P.; Hunt, Brian D.; Foote, Marc C.

    1992-01-01

    New combinations of materials proposed for superconductor/normal-metal/superconductor (SNS) heterojunctions in low-temperature electronic devices such as fast switches, magnetometers, and mixers. Epitaxial heterojunctions formed between high-temperature superconductors and either oxide semiconductors or metals. Concept offers alternative to other three-layer heterojunction concepts; physical principles of operation permit SNS devices to have thicker barrier layers and fabricated more easily.

  3. Interaction Problems Accessing E-Learning Environments in Multi-Touch Mobile Devices: A Case Study in TelEduc

    ERIC Educational Resources Information Center

    da Silva, André Constantino; Freire, Fernanda Maria Pereira; de Arruda, Alan Victor Pereira; da Rocha, Heloísa Vieira

    2013-01-01

    e-Learning environments offer content, such text, audio, video, animations, using the Web infrastructure and they are designed to users interacting with keyboard, mouse and a medium-sized screen. Mobile devices, such as smartphones and tablets, have enough computation power to render Web pages, allowing browsing the Internet and access e-Learning…

  4. A Study of Using Technology Acceptance Model and Its Effect on Improving Road Pavement Smoothness in Taiwan

    ERIC Educational Resources Information Center

    Huang, Long-Sheng; Huang, Chung-Fah

    2017-01-01

    Using the technology acceptance model (TAM) as its theoretical foundation, this study intends to explore the use of Travelling Beam devices in road engineerings in Taiwan and offer suggestions based on its findings to encourage industry willingness for device deployment resulting in improving road pavement smoothness in Taiwan. The study subjects…

  5. A System for Reflective Learning Using Handwriting Tablet Devices for Real-Time Event Bookmarking into Simultaneously Recorded Videos

    ERIC Educational Resources Information Center

    Nakajima, Taira

    2012-01-01

    The author demonstrates a new system useful for reflective learning. Our new system offers an environment that one can use handwriting tablet devices to bookmark symbolic and descriptive feedbacks into simultaneously recorded videos in the environment. If one uses video recording and feedback check sheets in reflective learning sessions, one can…

  6. 78 FR 20969 - Self-Regulatory Organizations; NYSE MKT LLC; Notice of Filing and Immediate Effectiveness of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-08

    ... available on the Exchange's Web site at www.nyse.com , at the principal office of the Exchange, and at the... offered in a manner to facilitate its distribution via Web sites or mobile devices. \\5\\ See id. at 31501... data vendors, television broadcasters, Web site and mobile device service providers, and others to...

  7. Proceedings of the Hydrokinetic and Wave Energy Technologies Technical and Environmental Issues Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2006-03-01

    Renewable energy technologies offer the promise of non-polluting alternatives to fossil and nuclear-fueled power plants to meet growing demand for electrical energy. Two emerging categories of renewable energy technologies, hydrokinetic and wave energy conversion devices, offer ways to tap the energy of moving water without impoundment (dams) or diversion required by many conventional hydroelectric facilities. These technologies include devices designed for deployment in natural streams, tidal estuaries, ocean currents, and constructed waterways, as well as devices designed to capture the energy of ocean waves. On October 26-28, 2005, 54 representatives from government, non-governmental organizations, and private business met to (1)more » identify the varieties of hydrokinetic energy and wave technology devices, their stages of development, and the projected cost to bring each to market; (2) identify where these technologies can best operate; (3) identify the potential environmental issues associated with these technologies and possible mitigation measures; (4) develop a list of research needs and/or practical solutions to address unresolved environmental issues. These workshop proceedings include detailed summaries of the 24 presentations made and the discussions that followed.« less

  8. Development of advanced micromirror arrays by flip-chip assembly

    NASA Astrophysics Data System (ADS)

    Michalicek, M. Adrian; Bright, Victor M.

    2001-10-01

    This paper presents the design, commercial prefabrication, modeling and testing of advanced micromirror arrays fabricated using a novel, simple and inexpensive flip-chip assembly technique. Several polar piston arrays and rectangular cantilever arrays were fabricated using flip-chip assembly by which the upper layers of the array are fabricated on a separate chip and then transferred to a receiving module containing the lower layers. Typical polar piston arrays boast 98.3% active surface area, highly planarized surfaces, low address potentials compatible with CMOS electronics, highly standardized actuation between devices, and complex segmentation of mirror surfaces which allows for custom aberration configurations. Typical cantilever arrays boast large angles of rotation as well as an average surface planarity of only 1.779 nm of RMS roughness across 100 +m mirrors. Continuous torsion devices offer stable operation through as much as six degrees of rotation while binary operation devices offer stable activated positions with as much as 20 degrees of rotation. All arrays have desirable features of costly fabrication services like five structural layers and planarized mirror surfaces, but are prefabricated in the less costly MUMPs process. Models are developed for all devices and used to compare empirical data.

  9. A macrochip interconnection network enabled by silicon nanophotonic devices.

    PubMed

    Zheng, Xuezhe; Cunningham, John E; Koka, Pranay; Schwetman, Herb; Lexau, Jon; Ho, Ron; Shubin, Ivan; Krishnamoorthy, Ashok V; Yao, Jin; Mekis, Attila; Pinguet, Thierry

    2010-03-01

    We present an advanced wavelength-division multiplexing point-to-point network enabled by silicon nanophotonic devices. This network offers strictly non-blocking all-to-all connectivity while maximizing bisection bandwidth, making it ideal for multi-core and multi-processor interconnections. We introduce one of the key components, the nanophotonic grating coupler, and discuss, for the first time, how this device can be useful for practical implementations of the wavelength-division multiplexing network using optical proximity communications. Finite difference time-domain simulation of the nanophotonic grating coupler device indicates that it can be made compact (20 microm x 50 microm), low loss (3.8 dB), and broadband (100 nm). These couplers require subwavelength material modulation at the nanoscale to achieve the desired functionality. We show that optical proximity communication provides unmatched optical I/O bandwidth density to electrical chips, which enables the application of wavelength-division multiplexing point-to-point network in macrochip with unprecedented bandwidth-density. The envisioned physical implementation is discussed. The benefits of such an interconnect network include a 5-6x improvement in latency when compared to a purely electronic implementation. Performance analysis shows that the wavelength-division multiplexing point-to-point network offers better overall performance over other optical network architectures.

  10. The first radical-based spintronic memristors: Towards resistive RAMs made of organic magnets

    NASA Astrophysics Data System (ADS)

    Goss, Karin; Krist, Florian; Seyfferle, Simon; Hoefel, Udo; Paretzki, Alexa; Dressel, Martin; Bogani, Lapo; Institut Fuer Anorganische Chemie, University of Stuttgart Collaboration; 1. Physikalisches Institut, University of Stuttgart Team

    2014-03-01

    Using molecules as building blocks for electronic devices offers ample possibilities for new device functionalities due to a chemical tunability much higher than that of standard inorganic materials, and at the same time offers a decrease in the size of the electronic component down to the single-molecule level. Purely organic molecules containing no metallic centers such as organic radicals can serve as an electronic component with magnetic properties due to the unpaired electron in the radical state. Here we present memristive logic units based on organic radicals of the nitronyl-nitroxide kind. Integrating these purely molecular units as a spin coated layer into crossbar arrays, electrically induced unipolar resistive switching is observed with a change in resistance of up to 100%. We introduce a model based on filamentary reorganization of molecules of different oxidation state revealing the importance of the molecular nature for the switching properties. The major role of the oxidation state of these paramagnetic molecules introduces a magnetic field dependence to the device functionality, which goes along with magnetoresistive charactistics observed for the material. These are the first steps towards a spintronic implementation of organic radicals in electronic devices.

  11. Totally implanted ports: the trapezius approach in practice.

    PubMed

    Hill, Steve

    Implanted ports (IPs) are an essential device for many patients who require long-term vascular access. IPs offer some advantages over other central venous access devices, such as lifestyle, body image benefits and lower infection rates. A typical implantation site for a port is the anterior chest wall. For some patients with breast cancer who have metastatic chest wall disease this site may lead to problems with the function of the device if disease spreads to the port site. One option for this patient group is to place the implanted port over the trapezius muscle. This article discusses six patients, all of whom had metastatic breast cancer with some degree of subcutaneous disease on the anterior chest wall. Three patients had received trapezius port placements and three had anterior chest wall placements. A retrospective review of the patients' medical records was undertaken from the time of insertion until removal or until the patient died. The anterior chest wall group of patients had their devices in for an average of 368 days vs 214 in the trapezius group. The total complications were higher in the anterior chest wall group (7 vs 2 in the trapezius group). Disease spread to two of the devices in the anterior chest wall group meaning the devices could no longer be used. The trapezius approach appears to be a safe and a reliable form of vascular access and may offer fewer complications than the traditional method of anterior chest wall placement when standard anterior chest wall approach is not suitable.

  12. Organic electronics on fibers for energy conversion applications

    NASA Astrophysics Data System (ADS)

    O'Connor, Brendan T.

    Currently, there is great demand for pollution-free and renewable sources of electricity. Solar cells are particularly attractive from the standpoint of sunlight abundance. However, truly widespread adoption of solar cells is impeded by the high cost and poor scalability of existing technologies. For example, while 53,000 mi2 of 10% efficient solar cell modules would be required to supply the current U.S. energy demand, only about 50 mi2 have been installed worldwide. Organic semiconductors potentially offer a route to realizing low-cost solar cell modules, but currently suffer from low conversion efficiency. For organic-based solar cells to become commercially viable, further research is required to improve device performance, develop scalable manufacturing methods, and reduce installation costs via, for example, novel device form factors. This thesis makes several contributions to the field of organic solar cells, including the replacement of costly and brittle indium tin oxide (ITO) electrodes by inexpensive and malleable, thin metal films, and the application of external dielectric coatings to improve power conversion efficiency. Furthermore, we show that devices with non-planar geometries (e.g. organic solar cells deposited onto long fibers) can have higher efficiencies than conventional planar devices. Building on these results, we demonstrate novel fiber-based organic light emitting devices (OLEDs) that offer substantially improved color quality and manufacturability as a next-generation solid-state lighting technology. An intriguing possibility afforded by the fiber-based device architectures is the ability to integrate energy conversion and lighting functionalities with textiles, a mature, commodity-scale technology.

  13. Pushing the Performance Limit of Sub-100 nm Molybdenum Disulfide Transistors.

    PubMed

    Liu, Yuan; Guo, Jian; Wu, Yecun; Zhu, Enbo; Weiss, Nathan O; He, Qiyuan; Wu, Hao; Cheng, Hung-Chieh; Xu, Yang; Shakir, Imran; Huang, Yu; Duan, Xiangfeng

    2016-10-12

    Two-dimensional semiconductors (2DSCs) such as molybdenum disulfide (MoS 2 ) have attracted intense interest as an alternative electronic material in the postsilicon era. However, the ON-current density achieved in 2DSC transistors to date is considerably lower than that of silicon devices, and it remains an open question whether 2DSC transistors can offer competitive performance. A high current device requires simultaneous minimization of the contact resistance and channel length, which is a nontrivial challenge for atomically thin 2DSCs, since the typical low contact resistance approaches for 2DSCs either degrade the electronic properties of the channel or are incompatible with the fabrication process for short channel devices. Here, we report a new approach toward high-performance MoS 2 transistors by using a physically assembled nanowire as a lift-off mask to create ultrashort channel devices with pristine MoS 2 channel and self-aligned low resistance metal/graphene hybrid contact. With the optimized contact in short channel devices, we demonstrate sub-100 nm MoS 2 transistor delivering a record high ON-current of 0.83 mA/μm at 300 K and 1.48 mA/μm at 20 K, which compares well with that of silicon devices. Our study, for the first time, demonstrates that the 2DSC transistors can offer comparable performance to the 2017 target for silicon transistors in International Technology Roadmap for Semiconductors (ITRS), marking an important milestone in 2DSC electronics.

  14. Remote monitoring of cardiovascular implanted electronic devices: a paradigm shift for the 21st century.

    PubMed

    Cronin, Edmond M; Varma, Niraj

    2012-07-01

    Traditional follow-up of cardiac implantable electronic devices involves the intermittent download of largely nonactionable data. Remote monitoring represents a paradigm shift from episodic office-based follow-up to continuous monitoring of device performance and patient and disease state. This lessens device clinical burden and may also lead to cost savings, although data on economic impact are only beginning to emerge. Remote monitoring technology has the potential to improve the outcomes through earlier detection of arrhythmias and compromised device integrity, and possibly predict heart failure hospitalizations through integration of heart failure diagnostics and hemodynamic monitors. Remote monitoring platforms are also huge databases of patients and devices, offering unprecedented opportunities to investigate real-world outcomes. Here, the current status of the field is described and future directions are predicted.

  15. Fuselage Boundary Layer Ingestion Propulsion Applied to a Thin Haul Commuter Aircraft for Optimal Efficiency

    NASA Technical Reports Server (NTRS)

    Mikic, Gregor Veble; Stoll, Alex; Bevirt, JoeBen; Grah, Rok; Moore, Mark D.

    2016-01-01

    Theoretical and numerical aspects of aerodynamic efficiency of propulsion systems are studied. Focus is on types of propulsion that closely couples to the aerodynamics of the complete vehicle. We discuss the effects of local flow fields, which are affected both by conservative flow acceleration as well as total pressure losses, on the efficiency of boundary layer immersed propulsion devices. We introduce the concept of a boundary layer retardation turbine that helps reduce skin friction over the fuselage. We numerically investigate efficiency gains offered by boundary layer and wake interacting devices. We discuss the results in terms of a total energy consumption framework and show that efficiency gains offered depend on all the elements of the propulsion system.

  16. Printed Carbon Nanotube Electronics and Sensor Systems.

    PubMed

    Chen, Kevin; Gao, Wei; Emaminejad, Sam; Kiriya, Daisuke; Ota, Hiroki; Nyein, Hnin Yin Yin; Takei, Kuniharu; Javey, Ali

    2016-06-01

    Printing technologies offer large-area, high-throughput production capabilities for electronics and sensors on mechanically flexible substrates that can conformally cover different surfaces. These capabilities enable a wide range of new applications such as low-cost disposable electronics for health monitoring and wearables, extremely large format electronic displays, interactive wallpapers, and sensing arrays. Solution-processed carbon nanotubes have been shown to be a promising candidate for such printing processes, offering stable devices with high performance. Here, recent progress made in printed carbon nanotube electronics is discussed in terms of materials, processing, devices, and applications. Research challenges and opportunities moving forward from processing and system-level integration points of view are also discussed for enabling practical applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Ventricular Assist Device and Destination Therapy Candidates from Preoperative Selection Through End of Hospitalization.

    PubMed

    Doty, Diane

    2015-12-01

    Mechanical circulatory support (MCS) devices offer advanced heart failure patients a potential long-term solution. MCS devices implantation is increasing related to the increased volume of heart failure patients, the shortfall of suitable donors, and the advanced technology and smaller size of the devices. To ensure a successful outcome, some key elements must be taken into consideration and managed: patient selection, preoperative preparation, intraoperative care, postoperative care, and posthospital education. The ultimate success of an MCS implantation relies on a multidisciplinary approach and excellent patient/caregiver education in each phase of hospitalization. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Improved Design of Optical MEMS Using the SUMMiT Fabrication Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michalicek, M.A.; Comtois, J.H.; Barron, C.C.

    This paper describes the design and fabrication of optical Microelectromechanical Systems (MEMS) devices using the Sandia Ultra planar Multilevel MEMS Technology (SUMMiT) fabrication process. This state of the art process, offered by Sandia National Laboratories, provides unique and very advantageous features which make it ideal for optical devices. This enabling process permits the development of micromirror devices with near ideal characteristics which have previously been unrealizable in standard polysilicon processes. This paper describes such characteristics as elevated address electrodes, individual address wiring beneath the device, planarized mirror surfaces, unique post-process metallization, and the best active surface area to date.

  19. Applications of everyday IT and communications devices in modern analytical chemistry: A review.

    PubMed

    Grudpan, Kate; Kolev, Spas D; Lapanantnopakhun, Somchai; McKelvie, Ian D; Wongwilai, Wasin

    2015-05-01

    This paper reviews the development and recent use of everyday communications and IT equipment (mobile phones, digital cameras, scanners, webcams, etc) as detection devices for colorimetric chemistries. Such devices can readily be applied for visible detection using reaction formats such as microfluidic paper based analytical devices (µPADs), indicator papers, and well plate reaction vessels. Their use is highly advantageous with respect to cost, simplicity and portability, and offers many opportunities in the areas of point of care diagnosis, and at-site monitoring of environmental, agricultural, food and beverage parameters. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. A product-service system approach to telehealth application design.

    PubMed

    Flores-Vaquero, Paul; Tiwari, Ashutosh; Alcock, Jeffrey; Hutabarat, Windo; Turner, Chris

    2016-06-01

    A considerable proportion of current point-of-care devices do not offer a wide enough set of capabilities if they are to function in any telehealth system. There is a need for intermediate devices that lie between healthcare devices and service networks. The development of an application is suggested that allows for a smartphone to take the role of an intermediate device. This research seeks to identify the telehealth service requirements for long-term condition management using a product-service system approach. The use of product-service system has proven to be a suitable methodology for the design and development of telehealth smartphone applications. © The Author(s) 2014.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Kun; Marcus, Kyle; Yang, Zhenzhong

    In this work, a freestanding NiFe oxyfluoride (NiFeOF) holey film was prepared by electrochemical deposition and anodic treatments. With the combination of good electrical conductivity and holey structure, the NiFeOF holey film offers superior electrochemical performance, due to the following reasons: (i) The residual metal alloy framework can be used as the current collector to improve electrode conductivity. Moreover, the as-prepared freestanding NiFeOF holey film can be used as a supercapacitor electrode without reliance on binders and other additives. The residual metal alloy framework and binder-free electrode effectively reduces electrode resistance, thus improving electron transport. (ii) The highly interconnected holeymore » structure and hierarchical pore distribution provides a high specific surface area to improve electron transport, enhancing rapid ion transport and mitigating diffusion limitations throughout the holey film. (iii) The excellent mechanical characteristics facilitate flexibility and cyclability related performance. Additionally, the NiFeOF holey film presents exceptional electrochemical performance, showing that it is a promising alternative for small/micro-size electronic devices.« less

  2. Transformation from Nanofibers to Nanoribbons in Poly(3-hexylthiophene) Solution by Adding Alkylthiols.

    PubMed

    Pan, Shuang; Zhu, Mingjing; He, Luze; Zhang, Hongdong; Qiu, Feng; Lin, Zhiqun; Peng, Juan

    2018-05-10

    An intriguing morphological transition from poly(3-hexylthiophene) (P3HT) 1D nanofibers to 2D nanoribbons enabled by the addition of a series of alkylthiols is reported. First, P3HT 1D nanofibers are formed due to strong anisotropic π-π stacking between planar rigid backbones. Upon the addition of alkylthiols, P3HT nanofibers are transformed into nanoribbons associated with the crystallographic transition from edge-on orientation to flat-on orientation. The content of alkylthiols has a great influence on the P3HT morphology in the solution. The mechanism of such a morphological transformation is discussed based on the interaction between alkylthiols and P3HT chains. This work offers an effective strategy to tailor the crystal morphology and dimension of P3HT, which not only improves the understanding of P3HT crystallization but also may enable such discovery into conjugated polymer-based optoelectronic devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Wide-Field Fundus Autofluorescence for Retinitis Pigmentosa and Cone/Cone-Rod Dystrophy.

    PubMed

    Oishi, Akio; Oishi, Maho; Ogino, Ken; Morooka, Satoshi; Yoshimura, Nagahisa

    2016-01-01

    Retinitis pigmentosa and cone/cone-rod dystrophy are inherited retinal diseases characterized by the progressive loss of rod and/or cone photoreceptors. To evaluate the status of rod/cone photoreceptors and visual function, visual acuity and visual field tests, electroretinogram, and optical coherence tomography are typically used. In addition to these examinations, fundus autofluorescence (FAF) has recently garnered attention. FAF visualizes the intrinsic fluorescent material in the retina, which is mainly lipofuscin contained within the retinal pigment epithelium. While conventional devices offer limited viewing angles in FAF, the recently developed Optos machine enables recording of wide-field FAF. With wide-field analysis, an association between abnormal FAF areas and visual function was demonstrated in retinitis pigmentosa and cone-rod dystrophy. In addition, the presence of "patchy" hypoautofluorescent areas was found to be correlated with symptom duration. Although physicians should be cautious when interpreting wide-field FAF results because the peripheral parts of the image are magnified significantly, this examination method provides previously unavailable information.

  4. Controlling Gilbert damping in a YIG film using nonlocal spin currents

    NASA Astrophysics Data System (ADS)

    Haidar, M.; Dürrenfeld, P.; Ranjbar, M.; Balinsky, M.; Fazlali, M.; Dvornik, M.; Dumas, R. K.; Khartsev, S.; Åkerman, J.

    2016-11-01

    We demonstrate the control of Gilbert damping in 65-nm-thick yttrium iron garnet (YIG) films using a spin-polarized current generated by a direct current through a nanocontact, spin filtered by a thin Co layer. The magnetodynamics of both the YIG and the Co layers can be excited by a pulse-modulated microwave current injected through the nanocontact and the response detected as a lock-in amplified voltage over the device. The spectra show three clear peaks, two associated with the ferromagnetic resonance (FMR) in each layer, and an additional Co mode with a higher wave vector proportional to the inverse of the nanocontact diameter. By varying the sign and magnitude of the direct nanocontact current, we can either increase or decrease the linewidth of the YIG FMR peak consistent with additional positive or negative damping being exerted by the nonlocal spin current injected into the YIG film. Our nanocontact approach thus offers an alternative route in the search for auto-oscillations in YIG films.

  5. Dye-Incorporated Polynaphthalenediimide Acceptor for Additive-Free High-Performance All-Polymer Solar Cells.

    PubMed

    Chen, Dong; Yao, Jia; Chen, Lie; Yin, Jingping; Lv, Ruizhi; Huang, Bin; Liu, Siqi; Zhang, Zhi-Guo; Yang, Chunhe; Chen, Yiwang; Li, Yongfang

    2018-04-16

    All-polymer solar cells (all-PSCs) can offer unique advantages for applications in flexible devices, and naphthalene diimide (NDI)-based polymer acceptors are the widely used polymer acceptors. However, their power conversion efficiency (PCE) still lags behind that of state-of-the-art polymer solar cells, due to low light absorption, suboptimal energy levels and the strong aggregation of the NDI-based polymer acceptor. Herein, a rhodanine-based dye molecule was introduced into the NDI-based polymer acceptor by simple random copolymerization and showed an improved light absorption coefficient, an up-shifted lowest unoccupied molecular orbital level and reduced crystallization. Consequently, additive-free all-PSCs demonstrated a high PCE of 8.13 %, which is one of the highest performance characteristics reported for all-PSCs to date. These results indicate that incorporating a dye into the n-type polymer gives insight into the precise design of high-performance polymer acceptors for all-PSCs. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Amperometric Detection in Microchip Electrophoresis Devices: Effect of Electrode Material and Alignment on Analytical Performance

    PubMed Central

    Fischer, David J.; Hulvey, Matthew K.; Regel, Anne R.; Lunte, Susan M.

    2012-01-01

    The fabrication and evaluation of different electrode materials and electrode alignments for microchip electrophoresis with electrochemical (EC) detection is described. The influences of electrode material, both metal and carbon-based, on sensitivity and limits of detection (LOD) were examined. In addition, the effects of working electrode alignment on analytical performance (in terms of peak shape, resolution, sensitivity, and LOD) were directly compared. Using dopamine (DA), norepinephrine (NE), and catechol (CAT) as test analytes, it was found that pyrolyzed photoresist electrodes with end-channel alignment yielded the lowest limit of detection (35 nM for DA). In addition to being easier to implement, end-channel alignment also offered better analytical performance than off-channel alignment for the detection of all three analytes. In-channel electrode alignment resulted in a 3.6-fold reduction in peak skew and reduced peak tailing by a factor of 2.1 for catechol in comparison to end-channel alignment. PMID:19802847

  7. Eyeglasses based wireless electrolyte and metabolite sensor platform.

    PubMed

    Sempionatto, Juliane R; Nakagawa, Tatsuo; Pavinatto, Adriana; Mensah, Samantha T; Imani, Somayeh; Mercier, Patrick; Wang, Joseph

    2017-05-16

    The demand for wearable sensors has grown rapidly in recent years, with increasing attention being given to epidermal chemical sensing. Here, we present the first example of a fully integrated eyeglasses wireless multiplexed chemical sensing platform capable of real-time monitoring of sweat electrolytes and metabolites. The new concept has been realized by integrating an amperometric lactate biosensor and a potentiometric potassium ion-selective electrode into the two nose-bridge pads of the glasses and interfacing them with a wireless electronic backbone placed on the glasses' arms. Simultaneous real-time monitoring of sweat lactate and potassium levels with no apparent cross-talk is demonstrated along with wireless signal transduction. The electrochemical sensors were screen-printed on polyethylene terephthalate (PET) stickers and placed on each side of the glasses' nose pads in order to monitor sweat metabolites and electrolytes. The electronic backbone on the arms of the glasses' frame offers control of the amperometric and potentiometric transducers and enables Bluetooth wireless data transmission to the host device. The new eyeglasses system offers an interchangeable-sensor feature in connection with a variety of different nose-bridge amperometric and potentiometric sensor stickers. For example, the lactate bridge-pad sensor was replaced with a glucose one to offer convenient monitoring of sweat glucose. Such a fully integrated wireless "Lab-on-a-Glass" multiplexed biosensor platform can be readily expanded for the simultaneous monitoring of additional sweat electrolytes and metabolites.

  8. Experimental Measurement-Device-Independent Quantum Key Distribution

    NASA Astrophysics Data System (ADS)

    Liu, Yang; Chen, Teng-Yun; Wang, Liu-Jun; Liang, Hao; Shentu, Guo-Liang; Wang, Jian; Cui, Ke; Yin, Hua-Lei; Liu, Nai-Le; Li, Li; Ma, Xiongfeng; Pelc, Jason S.; Fejer, M. M.; Peng, Cheng-Zhi; Zhang, Qiang; Pan, Jian-Wei

    2013-09-01

    Quantum key distribution is proven to offer unconditional security in communication between two remote users with ideal source and detection. Unfortunately, ideal devices never exist in practice and device imperfections have become the targets of various attacks. By developing up-conversion single-photon detectors with high efficiency and low noise, we faithfully demonstrate the measurement-device-independent quantum-key-distribution protocol, which is immune to all hacking strategies on detection. Meanwhile, we employ the decoy-state method to defend attacks on a nonideal source. By assuming a trusted source scenario, our practical system, which generates more than a 25 kbit secure key over a 50 km fiber link, serves as a stepping stone in the quest for unconditionally secure communications with realistic devices.

  9. Experimental measurement-device-independent quantum key distribution.

    PubMed

    Liu, Yang; Chen, Teng-Yun; Wang, Liu-Jun; Liang, Hao; Shentu, Guo-Liang; Wang, Jian; Cui, Ke; Yin, Hua-Lei; Liu, Nai-Le; Li, Li; Ma, Xiongfeng; Pelc, Jason S; Fejer, M M; Peng, Cheng-Zhi; Zhang, Qiang; Pan, Jian-Wei

    2013-09-27

    Quantum key distribution is proven to offer unconditional security in communication between two remote users with ideal source and detection. Unfortunately, ideal devices never exist in practice and device imperfections have become the targets of various attacks. By developing up-conversion single-photon detectors with high efficiency and low noise, we faithfully demonstrate the measurement-device-independent quantum-key-distribution protocol, which is immune to all hacking strategies on detection. Meanwhile, we employ the decoy-state method to defend attacks on a nonideal source. By assuming a trusted source scenario, our practical system, which generates more than a 25 kbit secure key over a 50 km fiber link, serves as a stepping stone in the quest for unconditionally secure communications with realistic devices.

  10. Absorption and Emission of Light in Optoelectronic Nanomaterials: The Role of the Local Optical Environment.

    PubMed

    Jiménez-Solano, Alberto; Galisteo-López, Juan F; Míguez, Hernán

    2018-04-19

    Tailoring the interaction of electromagnetic radiation with matter is central to the development of optoelectronic devices. This becomes particularly relevant for a new generation of devices offering the possibility of solution processing with competitive efficiencies as well as new functionalities. These devices, containing novel materials such as inorganic colloidal quantum dots or hybrid organic-inorganic lead halide perovskites, commonly demand thin (tens of nanometers) active layers in order to perform optimally and thus maximizing the way electromagnetic radiation interacts with these layers is essential. In this Perspective, we discuss the relevance of tailoring the optical environment of the active layer in an optoelectronic device and illustrate it with two real-world systems comprising photovoltaic cells and light emitting devices.

  11. Spin Dependent Transport Properties of Metallic and Semiconducting Nanostructures

    NASA Astrophysics Data System (ADS)

    Sapkota, Keshab R.

    Present computing and communication devices rely on two different classes of technologies; information processing devices are based on electrical charge transport in semiconducting materials while information storage devices are based on orientation of electron spins in magnetic materials. A realization of a hybrid-type device that is based on charge as well as spin properties of electrons would perform both of these actions thereby enhancing computation power to many folds and reducing power consumptions. This dissertation focuses on the fabrication of such spin-devices based on metallic and semiconducting nanostructures which can utilize spin as well as charge properties of electrons. A simplified design of the spin-device consists of a spin injector, a semiconducting or metallic channel, and a spin detector. The channel is the carrier of the spin signal from the injector to the detector and therefore plays a crucial role in the manipulation of spin properties in the device. In this work, nanostructures like nanowires and nanostripes are used to function the channel in the spin-device. Methods like electrospinning, hydrothermal, and wet chemical were used to synthesize nanowires while physical vapor deposition followed by heat treatment in controlled environment was used to synthesis nanostripes. Spin-devices fabrication of the synthesized nanostructures were carried out by electron beam lithography process. The details of synthesis of nanostructures, device fabrication procedures and measurement techniques will be discussed in the thesis. We have successfully fabricated the spin-devices of tellurium nanowire, indium nanostripe, and indium oxide nanostripe and studied their spin transport properties for the first time. These spin-devices show large spin relaxation length compared to normal metals like copper and offer potentials for the future technologies. Further, Heusler alloys nanowires like nanowires of Co 2FeAl were synthesized and studied for electrical transport properties since such systems are halfmetallic in nature and promise the possibilities of spin injection and detection. The study was extended to dilute magnetic semiconducting nanowire system of Cd1-xMnxTe which possess both magnetic and semiconducting properties. In summary, the studies made in this thesis will offer a new understanding of spin transport behavior for future technology.

  12. Industrial-scale application of the plunger flow electro-oxidation reactor in wastewater depth treatment.

    PubMed

    Huang, Guolong; Yao, Jiachao; Pan, Weilong; Wang, Jiade

    2016-09-01

    Effluents after biochemical treatment contain pollutants that are mostly non-degradable. Based upon previous pilot-scale test results, an industrial-scale electro-oxidation device was built to decompose these refractory materials in the effluent from a park wastewater treatment plant. The electro-oxidation device comprised a ditch-shaped plunger flow electrolysis cell, with mesh-plate Ti/PbO2 electrodes as the anode and the same size mesh-plate Ti as the cathode. Wastewater flowed vertically through electrodes; the effective volume of the cell was 2.8 m(3), and the surface-to-volume ratio was 17.14 m(2) m(-3). The optimal current density was 100 A m(-2), and a suitable flow velocity was 14.0 m h(-1). The removal efficiencies for chemical oxygen demand and color in the effluent were over 60.0 and 84.0 %, respectively. In addition, the electro-oxidation system offered a good disinfection capability. The specific energy consumption for this industrial-scale device was 43.5 kWh kg COD(-1), with a current efficiency of 32.8 %, which was superior to the pilot-scale one. To meet the requirements for emission or reuse, the operation cost was $0.44 per ton of effluent at an average price for electricity of $0.11 kWh(-1).

  13. Thermal ink-jet device using single-chip silicon microchannels

    NASA Astrophysics Data System (ADS)

    Wuu, DongSing; Cheng, Chen-Yue; Horng, RayHua; Chan, G. C.; Chiu, Sao-Ling; Wu, Yi-Yung

    1998-06-01

    We present a new method to fabricate silicon microfluidic channels by through-hole etching with subsequent planarization. The method is based on etching out the deep grooves through a perforated silicon carbide membrane, followed by sealing the membrane with plasma-enhanced chemical vapor deposition (PECVD). Low-pressure-chemical-vapor- deposited (LPCVD) polysilicon was used as a sacrificial layer to define the channel structure and only one etching step is required. This permits the realization of planarization after a very deep etching step in silicon and offers the possibility for film deposition, resist spinning and film patterning across deep grooves. The process technology was demonstrated on the fabrication of a monolithic silicon microchannel structure for thermal inkjet printing. The Ta-Al heater arrays are integrated on the top of each microchannel, which connect to a common on-chip front-end ink reservoir. The fabrication of this device requires six masks and no active nozzle-to-chip alignment. Moreover, the present micromachining process is compatible with the addition of on-chip circuitry for multiplexing the heater control signals. Heat transfer efficiency to the ink is enhanced by the high thermal conductivity of the silicon carbide in the channel ceiling, while the bulk silicon maintains high interchannel isolation. The fabricated inkjet devices show the droplet sizes of 20 - 50 micrometer in diameter with various channel dimensions and stable ejection of ink droplets more than 1 million.

  14. Photonic Integrated Circuit (PIC) Device Structures: Background, Fabrication Ecosystem, Relevance to Space Systems Applications, and Discussion of Related Radiation Effects

    NASA Technical Reports Server (NTRS)

    Alt, Shannon

    2016-01-01

    Electronic integrated circuits are considered one of the most significant technological advances of the 20th century, with demonstrated impact in their ability to incorporate successively higher numbers transistors and construct electronic devices onto a single CMOS chip. Photonic integrated circuits (PICs) exist as the optical analog to integrated circuits; however, in place of transistors, PICs consist of numerous scaled optical components, including such "building-block" structures as waveguides, MMIs, lasers, and optical ring resonators. The ability to construct electronic and photonic components on a single microsystems platform offers transformative potential for the development of technologies in fields including communications, biomedical device development, autonomous navigation, and chemical and atmospheric sensing. Developing on-chip systems that provide new avenues for integration and replacement of bulk optical and electro-optic components also reduces size, weight, power and cost (SWaP-C) limitations, which are important in the selection of instrumentation for specific flight projects. The number of applications currently emerging for complex photonics systems-particularly in data communications-warrants additional investigations when considering reliability for space systems development. This Body of Knowledge document seeks to provide an overview of existing integrated photonics architectures; the current state of design, development, and fabrication ecosystems in the United States and Europe; and potential space applications, with emphasis given to associated radiation effects and reliability.

  15. A Small Modular Laboratory Hall Effect Thruster

    NASA Astrophysics Data System (ADS)

    Lee, Ty Davis

    Electric propulsion technologies promise to revolutionize access to space, opening the door for mission concepts unfeasible by traditional propulsion methods alone. The Hall effect thruster is a relatively high thrust, moderate specific impulse electric propulsion device that belongs to the class of electrostatic thrusters. Hall effect thrusters benefit from an extensive flight history, and offer significant performance and cost advantages when compared to other forms of electric propulsion. Ongoing research on these devices includes the investigation of mechanisms that tend to decrease overall thruster efficiency, as well as the development of new techniques to extend operational lifetimes. This thesis is primarily concerned with the design and construction of a Small Modular Laboratory Hall Effect Thruster (SMLHET), and its operation on argon propellant gas. Particular attention was addressed at low-cost, modular design principles, that would facilitate simple replacement and modification of key thruster parts such as the magnetic circuit and discharge channel. This capability is intended to facilitate future studies of device physics such as anomalous electron transport and magnetic shielding of the channel walls, that have an impact on thruster performance and life. Preliminary results demonstrate SMLHET running on argon in a manner characteristic of Hall effect thrusters, additionally a power balance method was utilized to estimate thruster performance. It is expected that future thruster studies utilizing heavier though more expensive gases like xenon or krypton, will observe increased efficiency and stability.

  16. E-Textile Antennas for Space Environments

    NASA Technical Reports Server (NTRS)

    Kennedy, Timothy F.; Fink, Patrick W.; Chu, Andrew W.

    2007-01-01

    The ability to integrate antennas and other radio frequency (RF) devices into wearable systems is increasingly important as wireless voice, video, and data sources become ubiquitous. Consumer applications including mobile computing, communications, and entertainment, as well as military and space applications for integration of biotelemetry, detailed tracking information and status of handheld tools, devices and on-body inventories are driving forces for research into wearable antennas and other e-textile devices. Operational conditions for military and space applications of wireless systems are often such that antennas are a limiting factor in wireless performance. The changing antenna platform, i.e. the dynamic wearer, can detune and alter the radiation characteristics of e-textile antennas, making antenna element selection and design challenging. Antenna designs and systems that offer moderate bandwidth, perform well with flexure, and are electronically reconfigurable are ideally suited to wearable applications. Several antennas, shown in Figure 1, have been created using a NASA-developed process for e-textiles that show promise in being integrated into a robust wireless system for space-based applications. Preliminary characterization of the antennas with flexure indicates that antenna performance can be maintained, and that a combination of antenna design and placement are useful in creating robust designs. Additionally, through utilization of modern smart antenna techniques, even greater flexibility can be achieved since antenna performance can be adjusted in real-time to compensate for the antenna s changing environment.

  17. A hybrid magnetic/complementary metal oxide semiconductor three-context memory bit cell for non-volatile circuit design

    NASA Astrophysics Data System (ADS)

    Jovanović, B.; Brum, R. M.; Torres, L.

    2014-04-01

    After decades of continued scaling to the beat of Moore's law, it now appears that conventional silicon based devices are approaching their physical limits. In today's deep-submicron nodes, a number of short-channel and quantum effects are emerging that affect the manufacturing process, as well as, the functionality of the microelectronic systems-on-chip. Spintronics devices that exploit both the intrinsic spin of the electron and its associated magnetic moment, in addition to its fundamental electronic charge, are promising solutions to circumvent these scaling threats. Being compatible with the CMOS technology, such devices offer a promising synergy of radiation immunity, infinite endurance, non-volatility, increased density, etc. In this paper, we present a hybrid (magnetic/CMOS) cell that is able to store and process data both electrically and magnetically. The cell is based on perpendicular spin-transfer torque magnetic tunnel junctions (STT-MTJs) and is suitable for use in magnetic random access memories and reprogrammable computing (non-volatile registers, processor cache memories, magnetic field-programmable gate arrays, etc). To demonstrate the potential our hybrid cell, we physically implemented a small hybrid memory block using 45 nm × 45 nm round MTJs for the magnetic part and 28 nm fully depleted silicon on insulator (FD-SOI) technology for the CMOS part. We also report the cells measured performances in terms of area, robustness, read/write speed and energy consumption.

  18. Nanostructured materials for advanced energy conversion and storage devices

    NASA Astrophysics Data System (ADS)

    Aricò, Antonino Salvatore; Bruce, Peter; Scrosati, Bruno; Tarascon, Jean-Marie; van Schalkwijk, Walter

    2005-05-01

    New materials hold the key to fundamental advances in energy conversion and storage, both of which are vital in order to meet the challenge of global warming and the finite nature of fossil fuels. Nanomaterials in particular offer unique properties or combinations of properties as electrodes and electrolytes in a range of energy devices. This review describes some recent developments in the discovery of nanoelectrolytes and nanoelectrodes for lithium batteries, fuel cells and supercapacitors. The advantages and disadvantages of the nanoscale in materials design for such devices are highlighted.

  19. BETA-GAMMA PERSONNEL DOSIMETER

    DOEpatents

    Davis, D.M.; Gupton, E.D.; Hart, J.C.; Hull, A.P.

    1961-01-17

    A personnel dosimeter is offered which is sensitive to both gamma and soft beta radiations from all directions within a hemisphere. The device is in the shape of a small pill box which is worn on a worker-s wrist. The top and sides of the device are provided with 50 per cent void areas to give 50 per cent response to the beta rays and complete response to the gamma rays. The device is so constructed as to have a response which will approximate the dose received by the basal layer of the human epidermis.

  20. Multiple wavelength silicon photonic 200 mm R+D platform for 25Gb/s and above applications

    NASA Astrophysics Data System (ADS)

    Szelag, B.; Blampey, B.; Ferrotti, T.; Reboud, V.; Hassan, K.; Malhouitre, S.; Grand, G.; Fowler, D.; Brision, S.; Bria, T.; Rabillé, G.; Brianceau, P.; Hartmann, J. M.; Hugues, V.; Myko, A.; Elleboode, F.; Gays, F.; Fédéli, J. M.; Kopp, C.

    2016-05-01

    A silicon photonics platform that uses a CMOS foundry line is described. Fabrication process is following a modular integration scheme which leads to a flexible platform, allowing different device combinations. A complete device library is demonstrated for 1310 nm applications with state of the art performances. A PDK which includes specific photonic features and which is compatible with commercial EDA tools has been developed allowing an MPW shuttle service. Finally platform evolutions such as device offer extension to 1550 nm or new process modules introduction are presented.

  1. Integrated digital metamaterials enables ultra-compact optical diodes

    DOE PAGES

    Shen, Bing; Polson, Randy; Menon, Rajesh

    2015-01-01

    We applied nonlinear optimization to design integrated digital metamaterials in silicon for unidirectional energy flow. Two devices, one for each polarization state, were designed, fabricated, and characterized. Both devices offer comparable or higher transmission efficiencies and extinction ratios, are easier to fabricate, exhibit larger bandwidths and are more tolerant to fabrication errors, when compared to alternatives. Furthermore, each device footprint is only 3μm × 3μm, which is the smallest optical diode ever reported. To illustrate the versatility of digital metamaterials, we also designed a polarization-independent optical diode.

  2. Effects of surface properties on droplet formation inside a microfluidic device

    NASA Astrophysics Data System (ADS)

    Steinhaus, Ben; Shen, Amy

    2004-11-01

    Micro-fluidic devices offer a unique method of creating and controlling droplets on small length scales. A microfluidic device is used to study the effects of surface properties on droplet formation of a 2-phase flow system. Four phase diagrams are generated to compare the dynamics of the 2 immiscible fluid system (silicone oil and water) inside microchannels with different surface properties. Results show that the channel surface plays an important role in determining the flow patterns and the droplet formation of the 2-phase fluid system.

  3. Low power signal processing electronics for wearable medical devices.

    PubMed

    Casson, Alexander J; Rodriguez-Villegas, Esther

    2010-01-01

    Custom designed microchips, known as Application Specific Integrated Circuits (ASICs), offer the lowest possible power consumption electronics. However, this comes at the cost of a longer, more complex and more costly design process compared to one using generic, off-the-shelf components. Nevertheless, their use is essential in future truly wearable medical devices that must operate for long periods of time from physically small, energy limited batteries. This presentation will demonstrate the state-of-the-art in ASIC technology for providing online signal processing for use in these wearable medical devices.

  4. A new XUV optical end-station to characterize compact and flexible photonic devices using synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Marcelli, A.; Mazuritskiy, M. I.; Dabagov, S. B.; Hampai, D.; Lerer, A. M.; Izotova, E. A.; D'Elia, A.; Turchini, S.; Zema, N.; Zuccaro, F.; de Simone, M.; Javad Rezvani, S.; Coreno, M.

    2018-03-01

    In this contribution we present the new experimental end-station to characterize XUV diffractive optics, such as Micro Channel Plates (MCPs) and other polycapillary optics, presently under commission at the Elettra synchrotron radiation laboratory (Trieste, Italy). To show the opportunities offered by these new optical devices for 3rd and 4th generation radiation sources, in this work we present also some patterns collected at different energies of the primary XUV radiation transmitted by MCP optical devices working in the normal incidence geometry.

  5. Deformable inorganic semiconductor

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Hyeong; Cha, Gi Doo

    2018-05-01

    Unlike conventional inorganic semiconductors, which are typically brittle, α-Ag2S exhibits room-temperature ductility with favourable electrical properties, offering promise for use in high-performance flexible and stretchable devices.

  6. The Evolution of Pressurized Metered-Dose Inhalers from Early to Modern Devices.

    PubMed

    Roche, Nicolas; Dekhuijzen, P N Richard

    2016-08-01

    Pressurized metered-dose inhalers (pMDIs) are sometimes viewed as old-fashioned and as having been superseded by dry powder inhalers (DPIs). Here, we review the technological advances that characterize modern pMDIs, and consider how they can influence the effectiveness of drug delivery for patients with asthma and chronic obstructive pulmonary disease. Compared with old chlorofluorocarbon (CFC)-based inhalers, many hydrofluoroalkane (HFA)-driven pMDIs have more favorable plume characteristics such as a reduced velocity and a higher fine particle fraction; together, these advances have resulted in the development of pMDIs with reduced oropharyngeal deposition and increased lung deposition. In addition, the plume from many HFA-pMDIs is warmer, which may facilitate their use by patients; moreover, devices are equipped with dose counters, which improves their reliability. As well as reviewing the technological advances of pMDIs, we also discuss the importance of individualizing inhaler therapies to each patient by accounting for their personal preferences and natural breathing patterns. Because pMDIs and DPIs differ considerably in their handling characteristics, matching the right inhaler to the right patient is key to ensuring effective therapy and good compliance. Finally, the majority of patients can be trained successfully in the correct use of their pMDI; training and regular monitoring of inhalation technique are essential prerequisites for effective therapy. While the 'ideal inhaler' may not exist, pMDIs are an effective device option suitable for many patients. pMDIs, together with other types of devices, offer opportunities for the effective individualization of treatments.

  7. Self-Fitting Hearing Aids

    PubMed Central

    Convery, Elizabeth

    2016-01-01

    A self-contained, self-fitting hearing aid (SFHA) is a device that enables the user to perform both threshold measurements leading to a prescribed hearing aid setting and fine-tuning, without the need for audiological support or access to other equipment. The SFHA has been proposed as a potential solution to address unmet hearing health care in developing countries and remote locations in the developed world and is considered a means to lower cost and increase uptake of hearing aids in developed countries. This article reviews the status of the SFHA and the evidence for its feasibility and challenges and predicts where it is heading. Devices that can be considered partly or fully self-fitting without audiological support were identified in the direct-to-consumer market. None of these devices are considered self-contained as they require access to other hardware such as a proprietary interface, computer, smartphone, or tablet for manipulation. While there is evidence that self-administered fitting processes can provide valid and reliable results, their success relies on user-friendly device designs and interfaces and easy-to-interpret instructions. Until these issues have been sufficiently addressed, optional assistance with the self-fitting process and on-going use of SFHAs is recommended. Affordability and a sustainable delivery system remain additional challenges for the SFHA in developing countries. Future predictions include a growth in self-fitting products, with most future SFHAs consisting of earpieces that connect wirelessly with a smartphone and providers offering assistance through a telehealth infrastructure, and the integration of SFHAs into the traditional hearing health-care model. PMID:27072929

  8. A brief review on microfluidic platforms for hormones detection.

    PubMed

    Ozhikandathil, Jayan; Badilescu, Simona; Packirisamy, Muthukumaran

    2017-01-01

    Lab-on-chip technology is attracting great interest due to its potential as miniaturized devices that can automate and integrate many sample-handling steps, minimize consumption of reagent and samples, have short processing time and enable multiplexed analysis. Microfluidic devices have demonstrated their potential for a broad range of applications in life sciences, including point-of-care diagnostics and personalized medicine, based on the routine diagnosis of levels of hormones, cancer markers, and various metabolic products in blood, serum, etc. Microfluidics offers an adaptable platform that can facilitate cell culture as well as monitor their activity and control the cellular environment. Signaling molecules released from cells such as neurotransmitters and hormones are important in assessing the health of cells and the effect of drugs on their functions. In this review, we provide an insight into the state-of-art applications of microfluidics for monitoring of hormones released by cells. In our works, we have demonstrated efficient detection methods for bovine growth hormones using nano and microphotonics integrated microfluidics devices. The bovine growth hormone can be used as a growth promoter in dairy farming to enhance the milk and meat production. In the recent years, a few attempts have been reported on developing very sensitive, fast and low-cost methods of detection of bovine growth hormone using micro devices. This paper reviews the current state-of-art of detection and analysis of hormone using integrated optical micro and nanofluidics systems. In addition, the paper also focuses on various lab-on-a-chip technologies reported recently, and their benefits for screening growth hormones in milk.

  9. Assessing the Educational Value of One-to-One Devices: Have We Been Asking the Right Questions?

    ERIC Educational Resources Information Center

    Blikstad-Balas, Marte; Davies, Chris

    2017-01-01

    The provision for every pupil in schools of one-to-one digital devices such as tablets and laptops is claimed to offer a range of benefits, both practical and educational. Opinions are still divided as to whether the benefits for teaching and learning in fact outweigh the cost, disruption to established teaching practice, and distraction for…

  10. The grays of medical device color additives.

    PubMed

    Seidman, Brenda

    2014-01-01

    The United States' medical device color additive regulations are unknown to some, and confusing to many. This article reviews statutory language on color additives in the Federal Food, Drug, and Cosmetic Act (FFDCA), as amended, including the Delaney Clause on carcinogenicity; color additive regulatory language as it relates to medical devices in Title 21 of the Code of Federal Regulations (C.F.R.), Parts 70-82; reports on the Food and Drug Administration's (FDA's) likely current and historical practices in dealing with color additives in medical devices; and speculates on what may have given rise to decades of seemingly ad hoc color additives practices, which may now be difficult to reconstruct and satisfactorily modify. Also addressed is the Center for Devices and Radiological Health's (CDRH's) recent publicly-vetted approach to color additives in Section 7 of its April 2013 draft guidance, Use of International Standard ISO-10993, "Biological Evaluation of Medical Devices Part 1: Evaluation and Testing," which the author concludes is a change in the right direction, but which, at least in its current draft form, is not a fix to the CDRH's color additives dilemma. Lastly, the article suggests what the CDRH might consider in further developing a new approach to color additives. Such an approach would treat color additives as if they were any other potentially toxic group of chemicals, and could be fashioned in such a way that the CDRH could still satisfy the broad aspects of Congressional color additives mandates, and.yet be consistent with ISO 10993. In doing this, the CDRH would need to recommend a more directed use of its Quality System Regulation, 21 C.F.R. Part 820, for material and vendor qualification and validation in general; approach Congress for needed statutory changes; or make administrative changes. In order for any approach to be successful, whether it is a new twist on past practices, or an entirely new path forward, the FDA must, to the best of its ability, better understand its past medical device color additive practices (as well as the variations that have developed within the last twenty or so years), and engage in a dialogue with stakeholders on how it and the medical device industry should consider unlisted color additives currently used in marketed devices in the United States.

  11. Smart energy management system

    NASA Astrophysics Data System (ADS)

    Desai, Aniruddha; Singh, Jugdutt

    2010-04-01

    Peak and average energy usage in domestic and industrial environments is growing rapidly and absence of detailed energy consumption metrics is making systematic reduction of energy usage very difficult. Smart energy management system aims at providing a cost-effective solution for managing soaring energy consumption and its impact on green house gas emissions and climate change. The solution is based on seamless integration of existing wired and wireless communication technologies combined with smart context-aware software which offers a complete solution for automation of energy measurement and device control. The persuasive software presents users with easy-to-assimilate visual cues identifying problem areas and time periods and encourages a behavioural change to conserve energy. The system allows analysis of real-time/statistical consumption data with the ability to drill down into detailed analysis of power consumption, CO2 emissions and cost. The system generates intelligent projections and suggests potential methods (e.g. reducing standby, tuning heating/cooling temperature, etc.) of reducing energy consumption. The user interface is accessible using web enabled devices such as PDAs, PCs, etc. or using SMS, email, and instant messaging. Successful real-world trial of the system has demonstrated the potential to save 20 to 30% energy consumption on an average. Low cost of deployment and the ability to easily manage consumption from various web enabled devices offers gives this system a high penetration and impact capability offering a sustainable solution to act on climate change today.

  12. Maintaining persistence and adherence with subcutaneous growth-hormone therapy in children: comparing jet-delivery and needle-based devices

    PubMed Central

    Spoudeas, Helen A; Bajaj, Priti; Sommerford, Nathan

    2014-01-01

    Purpose Persistence and adherence with subcutaneous growth hormone (GH; somatropin) therapy in children is widely acknowledged to be suboptimal. This study aimed to investigate how the use of a jet-delivery device, ZomaJet®, impacts on medication-taking behaviors compared to needle-based devices. Materials and methods A retrospective cohort study of children aged ≤18 years was conducted using a UK-based, nationwide database of GH home-delivery schedules. Data were evaluated for the period between January 2010 and December 2012 for 6,061 children receiving either Zomacton® (somatropin) via the ZomaJet jet-delivery device or one of six brands of GH all administered via needle-based devices. Persistence was analyzed for patients with appropriate data, measured as the time interval between first and last home deliveries. An analysis of adherence was conducted only for patients using ZomaJet who had appropriate data, measured by proportion of days covered. Brand switches were identified for all patients. Results Persistence with GH therapy was significantly longer in patients using ZomaJet compared to needle-based devices (599 days versus 535 days, respectively, n=4,093; P<0.001); this association was observed in both sexes and across age subgroups (≤10 and 11–16 years). The majority (58%) of patients using ZomaJet were classed as adherent (n=728). Only 297 patients (5%) switched GH brand (n=6,061), and patients tended to use ZomaJet for longer than other devices before switching. Conclusion It appears important that the choice of a jet-delivery device is offered to children prescribed daily GH therapy. These devices may represent a much-needed effective strategy for maintaining persistence with subcutaneous GH administration in children, potentially offering better clinical outcomes and greater cost-efficiency. PMID:25258519

  13. What Pacemakers Can Teach Us about the Ethics of Maintaining Artificial Organs.

    PubMed

    Hutchison, Katrina; Sparrow, Robert

    2016-11-01

    One day soon it may be possible to replace a failing heart, liver, or kidney with a long-lasting mechanical replacement or perhaps even with a 3-D printed version based on the patient's own tissue. Such artificial organs could make transplant waiting lists and immunosuppression a thing of the past. Supposing that this happens, what will the ongoing care of people with these implants involve? In particular, how will the need to maintain the functioning of artificial organs over an extended period affect patients and their doctors and the responsibilities of those who manufacture such devices? Drawing on lessons from the history of the cardiac pacemaker, this article offers an initial survey of the ethical issues posed by the need to maintain and service artificial organs. We briefly outline the nature and history of cardiac pacemakers, with a particular focus on the need for technical support, maintenance, and replacement of these devices. Drawing on the existing medical literature and on our conversations and correspondence with cardiologists, regulators, and manufacturers, we describe five sources of ethical issues associated with pacemaker maintenance: the location of the devices inside the human body, such that maintenance generates surgical risks; the complexity of the devices, which increases the risk of harms to patients as well as introducing potential injustices in access to treatment; the role of software-particularly software that can be remotely accessed-in the functioning of the devices, which generates privacy and security issues; the impact of continual development and improvement of the device; and the influence of commercial interests in the context of a medical device market in which there are several competing products. Finally, we offer some initial suggestions as to how these questions should be answered. © 2016 The Hastings Center.

  14. Pen Devices for Insulin Self-Administration Compared With Needle and Vial: Systematic Review of the Literature and Meta-Analysis.

    PubMed

    Lasalvia, Pieralessandro; Barahona-Correa, Julián Esteban; Romero-Alvernia, Diana Marcela; Gil-Tamayo, Sebastián; Castañeda-Cardona, Camilo; Bayona, Juan Gabriel; Triana, Juan José; Laserna, Andrés Felipe; Mejía-Torres, Miguel; Restrepo-Jimenez, Paula; Jimenez-Zapata, Juliana; Rosselli, Diego

    2016-07-01

    Pen devices offer advantages compared with vial and syringe (VaS). The purpose of this article was to evaluate efficacy of pen devices compared to VaS. A systematic review of literature was performed in 8 different databases. References were independently screened and selected. Primary observational or experimental studies comparing pen devices with VaS for insulin administrations were included. Studies on specific populations were excluded. Risk of bias was evaluated using appropriate tools. Data on glycosylated hemoglobin (HbA1c), hypoglycemia, adherence, persistence, patient preference, and quality of life (QOL) were collected. Meta-analysis was performed when appropriate. Heterogeneity and risk of publication bias were evaluated. Otherwise, descriptive analyses of the available data was done. In all, 10 348 articles were screened. A total of 17 studies were finally selected: 7 experimental and 10 analytical. The populations of the included articles were mainly composed of adults with type 2 diabetes mellitus. Important risk of bias was found in all of the articles, particularly experimental studies. Meta-analyses were performed for HbA1c, hypoglycemia, adherence and persistence. Pen device showed better results in mean HbA1c change, patients with hypoglycemia, adherence and persistence compared to VaS. No difference was observed in number of patients achieving <7% HbA1c. Preference studies showed a tendency favoring pen devices, however nonvalidated tools were used. One QoL study showed improvements in some subscales of SF-36. There is evidence that pen devices offer benefits in clinical and, less clearly, patient-reported outcomes compared to VaS for insulin administration. However, these results should be taken with caution. © 2016 Diabetes Technology Society.

  15. Non-Uniform Thickness Electroactive Device

    NASA Technical Reports Server (NTRS)

    Su, Ji (Inventor); Harrison, Joycelyn S. (Inventor)

    2006-01-01

    An electroactive device comprises at least two layers of material, wherein at least one layer is an electroactive material and wherein at least one layer is of non-uniform thickness. The device can be produced in various sizes, ranging from large structural actuators to microscale or nanoscale devices. The applied voltage to the device in combination with the non-uniform thickness of at least one of the layers (electroactive and/or non-electroactive) controls the contour of the actuated device. The effective electric field is a mathematical function of the local layer thickness. Therefore, the local strain and the local bending/ torsion curvature are also a mathematical function of the local thickness. Hence the thinnest portion of the actuator offers the largest bending and/or torsion response. Tailoring of the layer thicknesses can enable complex motions to be achieved.

  16. Technology for noninvasive mechanical ventilation: looking into the black box

    PubMed Central

    Navajas, Daniel; Montserrat, Josep M.

    2016-01-01

    Current devices for providing noninvasive respiratory support contain sensors and built-in intelligence for automatically modifying ventilation according to the patient's needs. These devices, including automatic continuous positive airway pressure devices and noninvasive ventilators, are technologically complex and offer a considerable number of different modes of ventilation and setting options, the details of which are sometimes difficult to capture by the user. Therefore, better predicting and interpreting the actual performance of these ventilation devices in clinical application requires understanding their functioning principles and assessing their performance under well controlled bench test conditions with simulated patients. This concise review presents an updated perspective of the theoretical basis of intelligent continuous positive airway pressure and noninvasive ventilation devices, and of the tools available for assessing how these devices respond under specific ventilation phenotypes in patients requiring breathing support. PMID:27730162

  17. Single event upset sensitivity of low power Schottky devices

    NASA Technical Reports Server (NTRS)

    Price, W. E.; Nichols, D. K.; Measel, P. R.; Wahlin, K. L.

    1982-01-01

    Data taken from tests involving heavy ions in the Berkeley 88 in. cyclotron being directed at low power Schottky barrier devices are reported. The tests also included trials in the Harvard cyclotron with 130 MeV protons, and at the U.C. Davis cyclotron using 56 MeV protons. The experiments were performed to study the single event upsets in MSI logic devices containing flip-flops. Results are presented of single-event upsets (SEU) causing functional degradation observed in post-exposure tests of six different devices. The effectiveness of the particles in producing SEUs in logic device functioning was found to be directly proportional to the proton energy. Shielding was determined to offer negligible protection from the particle bombardment. The results are considered significant for the design and fabrication of LS devices for space applications.

  18. Architecting Graphene Oxide Rolled-Up Micromotors: A Simple Paper-Based Manufacturing Technology.

    PubMed

    Baptista-Pires, Luis; Orozco, Jahir; Guardia, Pablo; Merkoçi, Arben

    2018-01-01

    A graphene oxide rolled-up tube production process is reported using wax-printed membranes for the fabrication of on-demand engineered micromotors at different levels of oxidation, thickness, and lateral dimensions. The resultant graphene oxide rolled-up tubes can show magnetic and catalytic movement within the addition of magnetic nanoparticles or sputtered platinum in the surface of graphene-oxide-modified wax-printed membranes prior to the scrolling process. As a proof of concept, the as-prepared catalytic graphene oxide rolled-up micromotors are successfully exploited for oil removal from water. This micromotor production technology relies on an easy, operator-friendly, fast, and cost-efficient wax-printed paper-based method and may offer a myriad of hybrid devices and applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Context-Based Tourism Information Filtering with a Semantic Rule Engine

    PubMed Central

    Lamsfus, Carlos; Martin, David; Alzua-Sorzabal, Aurkene; López-de-Ipiña, Diego; Torres-Manzanera, Emilio

    2012-01-01

    This paper presents the CONCERT framework, a push/filter information consumption paradigm, based on a rule-based semantic contextual information system for tourism. CONCERT suggests a specific insight of the notion of context from a human mobility perspective. It focuses on the particular characteristics and requirements of travellers and addresses the drawbacks found in other approaches. Additionally, CONCERT suggests the use of digital broadcasting as push communication technology, whereby tourism information is disseminated to mobile devices. This information is then automatically filtered by a network of ontologies and offered to tourists on the screen. The results obtained in the experiments carried out show evidence that the information disseminated through digital broadcasting can be manipulated by the network of ontologies, providing contextualized information that produces user satisfaction. PMID:22778584

  20. Flexible Power Distribution Based on Point of Load Converters

    NASA Astrophysics Data System (ADS)

    Dhallewin, G.; Galiana, D.; Mollard, J. M.; Schaper, W.; Strixner, E.; Tonicello, F.; Triggianese, M.

    2014-08-01

    Present digital electronic loads require low voltages and suffer from high currents. In addition, they need several different voltage levels to supply the different parts of digital devices like the core, the input/output I/F, etc. Distributed Power Architectures (DPA) with point-of- load (POL) converters (synchronous buck type) offer excellent performance in term of efficiency and load step behaviour. They occupy little PCB area and are well suited for very low voltage (VLV) DC conversion (1V to 3.3V). The paper presents approaches to architectural design of POL based supplies including redundancy and protection as well as the requirements on a European hardware implementation. The main driver of the analysis is the flexibility of each element (DC/DC converter, protection, POL core) to cover a wide range of space applications.

Top