Adolescents' Use of Basic, Intermediate, and Advanced Device Types for Vaping.
Pepper, Jessica K; MacMonegle, Anna J; Nonnemaker, James M
2017-12-23
Advanced models of electronic vaping products (EVPs) likely pose a greater risk to adolescent health than basic or intermediate models because advanced models deliver nicotine more effectively and heat e-liquid to higher temperatures, producing more harmful chemical emissions. However, little is known about adolescents' risk factors for using different device types. We used social media to recruit an online sample of 1,508 U.S. adolescents aged 15-17 who reported past 30-day use of e-cigarettes. We assessed tobacco use, beliefs and knowledge about EVPs, and EVP use behavior, including the device type participants use most frequently. We used multinomial logistic regression to examine differences between adolescents who usually use intermediate versus basic and advanced versus basic devices. Most respondents usually used modifiable advanced devices (56.8%) rather than basic "cigalike" (14.5%) or pen-style intermediate (28.7%) devices. Use of multiple device types was common, particularly among those who primarily used basic devices. Younger age and less frequent vaping were associated with mainly using basic devices. Adolescents who were older, male, personally bought their main device, and had ever mixed e-liquids were at elevated risk for usually using advanced devices. Adolescents who primarily use basic devices may be newer users who are experimenting with multiple devices. Future research should examine which adolescents are most likely to transition to advanced devices in order to develop targeted interventions. Regulators should consider strategies to reduce access to all types of EVPs, such as better enforcement of the current ban on sales to minors. This research addresses two gaps in research on adolescent electronic vaping product use: (1) characterizing use of advanced devices as distinct from intermediate devices rather than grouping them together and (2) examining factors associated with use of specific device types. This study suggests that there are distinct profiles of adolescents who use primarily basic, intermediate, or advanced devices. Adolescents who most often use basic devices may be new users experimenting with vaping, whereas adolescents who most often use advanced devices appear to be buying devices for themselves and engaging in risky behaviors such as mixing their own e-liquid. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Disrupting Improvised Explosive Device Terror Campaigns: Basic Research Opportunities
2008-01-01
2008 2. REPORT TYPE 3. DATES COVERED 00-00-2008 to 00-00-2008 4. TITLE AND SUBTITLE Disrupting Improvised Explosive Device Terror Campaigns... Explosive Device Terror Campaigns: Basic Research Opportunities A WORKSHOP REPORT Committee on Defeating Improvised Explosive Devices...iv v COMMITTEE ON DEFEATING IMPROVISED EXPLOSIVE DEVICES: BASIC RESEARCH TO INTERRUPT THE IED DELIVERY CHAIN Chairperson
32 CFR 634.27 - Speed-measuring devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... devices. Speed-measuring devices will be used in traffic control studies and enforcement programs. Signs.... (v) Demonstrate basic skills in checking calibration and operating the specific radar instrument(s). (vi) Demonstrate basic skills in preparing and presenting records and courtroom testimony relating to...
Ladder-structured photonic variable delay device
NASA Technical Reports Server (NTRS)
Yao, X. Steve (Inventor)
1998-01-01
An ladder-structured variable delay device for providing variable true time delay to multiple optical beams simultaneously. The device comprises multiple basic units stacked on top of each other resembling a ladder. Each basic unit comprises a polarization sensitive corner reflector formed by two polarization beamsplitters and a polarization rotator array placed parallel to the hypotenuse of the corner reflector. Controlling an array element of the polarization rotator array causes an optical beam passing through the array element to either go up to a basic unit above it or reflect back towards output. The beams going higher on the ladder experience longer optical path delay. Finally, the ladder-structured variable device can be cascaded with another multi-channel delay device to form a new device which combines the advantages of the two individual devices. This programmable optic device has the properties of high packing density, low loss, easy fabrication, and virtually infinite bandwidth. In addition, the delay is reversible so that the same delay device can be used for both antenna transmitting and receiving.
NASA Astrophysics Data System (ADS)
Fischer, R.; Müller, R.
1989-08-01
It is shown that nonlinear optical devices are the most promising elements for an optical digital supercomputer. The basic characteristics of various developed nonlinear elements are presented, including bistable Fabry-Perot etalons, interference filters, self-electrooptic effect devices, quantum-well devices utilizing transitions between the lowest electron states in the conduction band of GaAs, etc.
Impact of Hearing Aid Technology on Outcomes in Daily Life I: the Patients’ Perspective
Cox, Robyn M; Johnson, Jani A; Xu, Jingjing
2016-01-01
Objectives One of the challenges facing hearing care providers when recommending hearing aids is the choice of device technology level. Major manufacturers market families of hearing aids that are described as spanning the range from basic technology to premium technology. Premium technology hearing aids include acoustical processing capabilities (features) that are not found in basic technology instruments. These premium features are intended to yield improved hearing in daily life compared to basic-feature devices. However, independent research that establishes the incremental effectiveness of premium-feature devices compared to basic-feature devices is lacking. This research was designed to explore reported differences in hearing abilities for adults using premium-feature and basic-feature hearing aids in their daily lives. Design This was a single-blinded, repeated, crossover trial in which the participants were blinded. All procedures were carefully controlled to limit researcher bias. Forty-five participants used carefully fitted bilateral hearing aids for one month and then provided data to describe the hearing improvements or deficiencies noted in daily life. Typical participants were 70 years old with mild to moderate adult-onset hearing loss bilaterally. Each participant used 4 pairs of hearing aids: premium- and basic-feature devices from brands marketed by each of two major manufacturers. Participants were blinded about the devices they used and about the research questions. Results All of the outcomes were designed to capture the participant’s point of view about the benefits of the hearing aids. Three types of data were collected: change in hearing-related quality of life, extent of agreement with six positively worded statements about everyday hearing with the hearing aids, and reported preferences between the premium- and basic-feature devices from each brand as well as across all four research hearing aids combined. None of these measures yielded a statistically significant difference in outcomes between premium- and basic-feature devices. Participants did not report better outcomes with premium processing with any measure. Conclusions It could reasonably be asserted that the patient’s perspective is the gold standard for hearing aid effectiveness. While the acoustical processing provided by premium features can potentially improve scores on tests conducted in contrived conditions in a laboratory, or on specific items in a questionnaire, this does not ensure that the processing will be of noteworthy benefit when the hearing aid is used in the real world challenges faced by the patient. If evidence suggests the patient cannot detect that premium features yield improvements over basic features in daily life, what is the responsibility of the provider in recommending hearing aid technology level? In the current research, there was no evidence to suggest that premium-feature devices yielded better outcomes than basic-feature devices from the patient’s point of view. All of the research hearing aids were substantially, but equally, helpful. Further research is needed on this topic with other hearing aids and other manufacturers. In the meantime, providers should insist on scientifically credible independent evidence to support effectiveness claims for any hearing help devices. PMID:26881981
Integrated Real-Time Control and Imaging System for Microbiorobotics and Nanobiostructures
2016-01-11
kit with a control board and ALP 4.1 basic controller suite. The digital micromirror device is the highest resolution 16:9 aspect ratio system. This...in Figure 1, consisted of the following: (1) digital micromirror device (DMD) and controller, (2) an inverted epifluorescence microscope with a flat...accompanying control board and ALP 4.1 basic controller suite. The digital micromirror device is currently the highest commercially available
Bryant, Jennifer E; Richard, Craig A H
To describe pharmacy students' use of mobile devices in a basic health science laboratory and to report the students' perceptions on how solving cases with their mobile devices influenced their attitudes, abilities, and view on the use of mobile devices as tools for pharmacists. First-year pharmacy students utilized mobile devices to solve clinical case studies in a basic health sciences laboratory. A pre-survey and two post-surveys were administered to assess the students' comfort, awareness, use, and perceptions on the use of their mobile devices and apps. The pre-survey and first post-survey each had a response rate of 99%, and the second post-survey had a response rate of 100%. In comparing the pre-survey and first post-survey data, there was a statistically significant increase in the number of students that agreed or strongly agreed that they were more comfortable utilizing their mobile device (p = 0.025), they were more aware of apps for pharmacists (p < 0.005), and they have used more apps that can be useful for pharmacists (p < 0.005). The second post-survey demonstrated that over 78% of students agreed or strongly agreed that completing the case studies influenced them to be more comfortable with their mobile devices, to be more aware of apps that can be useful for pharmacists, and to be more agreeable with mobile device utilization by pharmacists in improving patient care. In addition, the second post-survey also demonstrated that 84% of students responded that using their mobile devices to solve the cases influenced them to either use their mobile device in a clinical setting for a clinical and/or pharmacy-related purpose for the first time or to use it more frequently for this purpose. The use of mobile devices to solve clinical cases in a first-year basic health science laboratory course was perceived as beneficial by students and influenced them to utilize their mobile device even more in a pharmacy practice setting. Copyright © 2016 Elsevier Inc. All rights reserved.
Thyroid Radiofrequency Ablation: Updates on Innovative Devices and Techniques
Park, Hye Sun; Park, Auh Whan; Chung, Sae Rom; Choi, Young Jun; Lee, Jeong Hyun
2017-01-01
Radiofrequency ablation (RFA) is a well-known, effective, and safe method for treating benign thyroid nodules and recurrent thyroid cancers. Thyroid-dedicated devices and basic techniques for thyroid RFA were introduced by the Korean Society of Thyroid Radiology (KSThR) in 2012. Thyroid RFA has now been adopted worldwide, with subsequent advances in devices and techniques. To optimize the treatment efficacy and patient safety, understanding the basic and advanced RFA techniques and selecting the optimal treatment strategy are critical. The goal of this review is to therefore provide updates and analysis of current devices and advanced techniques for RFA treatment of benign thyroid nodules and recurrent thyroid cancers. PMID:28670156
Inhalers and nebulizers: basic principles and preliminary measurements
NASA Astrophysics Data System (ADS)
Misik, Ondrej; Lizal, Frantisek; Asl, Vahid Farhikhteh; Belka, Miloslav; Jedelsky, Jan; Elcner, Jakub; Jicha, Miroslav
2018-06-01
Inhalers are hand-held devices which are used for administration of therapeutic aerosols via inhalation. Nebulizers are larger devices serving for home and hospital care using inhaled medication. This contribution describes the basic principles of dispersion of aerosol particles used in various types of inhalers and nebulizers, and lists the basic physical mechanisms contributing to the deposition of inhaled particles in the human airways. The second part of this article presents experimental setup, methodology and preliminary results of particle size distributions produced by several selected inhalers and nebulizers.
Basic life support: evaluation of learning using simulation and immediate feedback devices1.
Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi
2017-10-30
to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.
Compact programmable photonic variable delay devices
NASA Technical Reports Server (NTRS)
Yao, X. Steve (Inventor)
1999-01-01
Optical variable delay devices for providing variable true time delay to multiple optical beams simultaneously. A ladder-structured variable delay device comprises multiple basic building blocks stacked on top of each other resembling a ladder. Each basic building block has two polarization beamsplitters and a polarization rotator array arranged to form a trihedron; Controlling an array element of the polarization rotator array causes a beam passing through the array element either going up to a basic building block above it or reflect back towards a block below it. The beams going higher on the ladder experience longer optical path delay. An index-switched optical variable delay device comprises of many birefringent crystal segments connected with one another, with a polarization rotator array sandwiched between any two adjacent crystal segments. An array element in the polarization rotator array controls the polarization state of a beam passing through the element, causing the beam experience different refractive indices or path delays in the following crystal segment. By independently control each element in each polarization rotator array, variable optical path delays of each beam can be achieved. Finally, an index-switched variable delay device and a ladder-structured variable device are cascaded to form a new device which combines the advantages of the two individual devices. This programmable optic device has the properties of high packing density, low loss, easy fabrication, and virtually infinite bandwidth. The device is inherently two dimensional and has a packing density exceeding 25 lines/cm.sup.2. The delay resolution of the device is on the order of a femtosecond (one micron in space) and the total delay exceeds 10 nanosecond. In addition, the delay is reversible so that the same delay device can be used for both antenna transmitting and receiving.
Photonic variable delay devices based on optical birefringence
NASA Technical Reports Server (NTRS)
Yao, X. Steve (Inventor)
2005-01-01
Optical variable delay devices for providing variable true time delay to multiple optical beams simultaneously. A ladder-structured variable delay device comprises multiple basic building blocks stacked on top of each other resembling a ladder. Each basic building block has two polarization beamsplitters and a polarization rotator array arranged to form a trihedron; Controlling an array element of the polarization rotator array causes a beam passing through the array element either going up to a basic building block above it or reflect back towards a block below it. The beams going higher on the ladder experience longer optical path delay. An index-switched optical variable delay device comprises of many birefringent crystal segments connected with one another, with a polarization rotator array sandwiched between any two adjacent crystal segments. An array element in the polarization rotator array controls the polarization state of a beam passing through the element, causing the beam experience different refractive indices or path delays in the following crystal segment. By independently control each element in each polarization rotator array, variable optical path delays of each beam can be achieved. Finally, an index-switched variable delay device and a ladder-structured variable device are cascaded to form a new device which combines the advantages of the two individual devices. This programmable optic device has the properties of high packing density, low loss, easy fabrication, and virtually infinite bandwidth. The device is inherently two dimensional and has a packing density exceeding 25 lines/cm2. The delay resolution of the device is on the order of a femtosecond (one micron in space) and the total delay exceeds 10 nanosecond. In addition, the delay is reversible so that the same delay device can be used for both antenna transmitting and receiving.
Regulatory Requirements for Devices for the Handicapped.
ERIC Educational Resources Information Center
Stigi, John, Ed.; Rivera, Richard J., Ed.
This booklet explains in question/answer form the basic regulatory requirements established by the Food and Drug Administration (FDA) of the federal government concerning the manufacture, marketing and distribution of medical devices (including implantable devices and devices previously regulated as drugs) for persons with disabilities. Topics…
ERIC Educational Resources Information Center
Chief of Naval Education and Training Support, Pensacola, FL.
This individualized learning module on special devices is one in a series of modules for a course in basic electricity and electronics. The course is one of a number of military-developed curriculum packages selected for adaptation to vocational instructional and curriculum development in a civilian setting. Four lessons are included in the…
ERIC Educational Resources Information Center
Chief of Naval Education and Training Support, Pensacola, FL.
This individualized learning module on special devices is one in a series of modules for a course in basic electricity and electronics. The course is one of a number of military-developed curriculum packages selected for adaptation to vocational instructional and curriculum development in a civilian setting. Two lessons are included in the module:…
Optoelectronic Devices with Complex Failure Modes
NASA Technical Reports Server (NTRS)
Johnston, A.
2000-01-01
This part of the NSREC-2000 Short Course discusses radiation effects in basic photonic devices along with effects in more complex optoelectronic devices where the overall radiation response depends on several factors, with the possibility of multiple failure modes.
BAM/DASS: Data Analysis Software for Sub-Microarcsecond Astrometry Device
NASA Astrophysics Data System (ADS)
Gardiol, D.; Bonino, D.; Lattanzi, M. G.; Riva, A.; Russo, F.
2010-12-01
The INAF - Osservatorio Astronomico di Torino is part of the Data Processing and Analysis Consortium (DPAC) for Gaia, a cornerstone mission of the European Space Agency. Gaia will perform global astrometry by means of two telescopes looking at the sky along two different lines of sight oriented at a fixed angle, also called basic angle. Knowledge of the basic angle fluctuations at the sub-microarcsecond level over periods of the order of the minute is crucial to reach the mission goals. A specific device, the Basic Angle Monitoring, will be dedicated to this purpose. We present here the software system we are developing to analyze the BAM data and recover the basic angle variations. This tool is integrated into the whole DPAC data analysis software.
Compact modeling of CRS devices based on ECM cells for memory, logic and neuromorphic applications.
Linn, E; Menzel, S; Ferch, S; Waser, R
2013-09-27
Dynamic physics-based models of resistive switching devices are of great interest for the realization of complex circuits required for memory, logic and neuromorphic applications. Here, we apply such a model of an electrochemical metallization (ECM) cell to complementary resistive switches (CRSs), which are favorable devices to realize ultra-dense passive crossbar arrays. Since a CRS consists of two resistive switching devices, it is straightforward to apply the dynamic ECM model for CRS simulation with MATLAB and SPICE, enabling study of the device behavior in terms of sweep rate and series resistance variations. Furthermore, typical memory access operations as well as basic implication logic operations can be analyzed, revealing requirements for proper spike and level read operations. This basic understanding facilitates applications of massively parallel computing paradigms required for neuromorphic applications.
Stroupe, Kevin T; Stelmack, Joan A; Tang, X Charlene; Wei, Yongliang; Sayers, Scott; Reda, Domenic J; Kwon, Ellen; Massof, Robert W
2018-05-01
Examining costs and consequences of different low-vision (LV) programs provides important information about resources needed to expand treatment options efficiently. To examine the costs and consequences of LV rehabilitation or basic LV services. The US Department of Veterans Affairs (VA) Low Vision Intervention Trial (LOVIT) II was conducted from September 27, 2010, to July 31, 2014, at 9 VA facilities and included 323 veterans with macular diseases and a best-corrected distance visual acuity of 20/50 to 20/200. Veterans were randomized to receive basic LV services that provided LV devices without therapy, or LV rehabilitation that added a therapist to LV services who provided instruction and homework on using LV devices, eccentric viewing, and environmental modification. We compared costs and consequences between these groups. Low-vision devices without therapy and LV devices with therapy. Costs of providing basic LV services or LV rehabilitation were assessed. We measured consequences as changes in functional visual ability from baseline to follow-up 4 months after randomization using the VA Low Vision Visual Functioning Questionnaire. Visual ability was measured in dimensionless log odds units (logits). Of 323 randomized patients, the mean (SD) age was 80 (10.5) years, 314 (97.2%) were men, and 292 (90.4%) were white. One hundred sixty (49.5%) received basic LV services and 163 (50.1%) received LV rehabilitation. The mean (SD) total direct health care costs per patient were similar between patients who were randomized to receive basic LV services ($1662 [$671]) or LV rehabilitation ($1788 [$864]) (basic LV services, $126 lower; 95% CI, $299 lower to $35 higher; P = .15). However, basic LV services required less time and had lower transportation costs. Patients receiving LV rehabilitation had greater improvements in overall visual ability, reading ability, visual information processing, and visual motor skill scores.
EduGATE - basic examples for educative purpose using the GATE simulation platform.
Pietrzyk, Uwe; Zakhnini, Abdelhamid; Axer, Markus; Sauerzapf, Sophie; Benoit, Didier; Gaens, Michaela
2013-02-01
EduGATE is a collection of basic examples to introduce students to the fundamental physical aspects of medical imaging devices. It is based on the GATE platform, which has received a wide acceptance in the field of simulating medical imaging devices including SPECT, PET, CT and also applications in radiation therapy. GATE can be configured by commands, which are, for the sake of simplicity, listed in a collection of one or more macro files to set up phantoms, multiple types of sources, detection device, and acquisition parameters. The aim of the EduGATE is to use all these helpful features of GATE to provide insights into the physics of medical imaging by means of a collection of very basic and simple GATE macros in connection with analysis programs based on ROOT, a framework for data processing. A graphical user interface to define a configuration is also included. Copyright © 2012. Published by Elsevier GmbH.
Radiological Dispersion Devices and Basic Radiation Science
ERIC Educational Resources Information Center
Bevelacqua, Joseph John
2010-01-01
Introductory physics courses present the basic concepts of radioactivity and an overview of nuclear physics that emphasizes the basic decay relationship and the various types of emitted radiation. Although this presentation provides insight into radiological science, it often fails to interest students to explore these concepts in a more rigorous…
Applications catalog of pyrotechnically actuated devices/systems
NASA Technical Reports Server (NTRS)
Seeholzer, Thomas L.; Smith, Floyd Z.; Eastwood, Charles W.; Steffes, Paul R.
1995-01-01
A compilation of basic information on pyrotechnically actuated devices/systems used in NASA aerospace and aeronautic applications was formatted into a catalog. The intent is to provide (1) a quick reference digest of the types of operational pyro mechanisms and (2) a source of contacts for further details. Data on these items was furnished by the NASA Centers that developed and/or utilized such devices to perform specific functions on spacecraft, launch vehicles, aircraft, and ground support equipment. Information entries include an item title, user center name, commercial contractor/vendor, identifying part number(s), a basic figure, briefly described purpose and operation, previous usage, and operational limits/requirements.
NASA Technical Reports Server (NTRS)
Miller, W. S.
1974-01-01
The cryogenic refrigerator thermal design calculations establish design approach and basic sizing of the machine's elements. After the basic design is defined, effort concentrates on matching the thermodynamic design with that of the heat transfer devices (heat exchangers and regenerators). Typically, the heat transfer device configurations and volumes are adjusted to improve their heat transfer and pressure drop characteristics. These adjustments imply that changes be made to the active displaced volumes, compensating for the influence of the heat transfer devices on the thermodynamic processes of the working fluid. Then, once the active volumes are changed, the heat transfer devices require adjustment to account for the variations in flows, pressure levels, and heat loads. This iterative process is continued until the thermodynamic cycle parameters match the design of the heat transfer devices. By examing several matched designs, a near-optimum refrigerator is selected.
Reconfigurable logic via gate controlled domain wall trajectory in magnetic network structure
Murapaka, C.; Sethi, P.; Goolaup, S.; Lew, W. S.
2016-01-01
An all-magnetic logic scheme has the advantages of being non-volatile and energy efficient over the conventional transistor based logic devices. In this work, we present a reconfigurable magnetic logic device which is capable of performing all basic logic operations in a single device. The device exploits the deterministic trajectory of domain wall (DW) in ferromagnetic asymmetric branch structure for obtaining different output combinations. The programmability of the device is achieved by using a current-controlled magnetic gate, which generates a local Oersted field. The field generated at the magnetic gate influences the trajectory of the DW within the structure by exploiting its inherent transverse charge distribution. DW transformation from vortex to transverse configuration close to the output branch plays a pivotal role in governing the DW chirality and hence the output. By simply switching the current direction through the magnetic gate, two universal logic gate functionalities can be obtained in this device. Using magnetic force microscopy imaging and magnetoresistance measurements, all basic logic functionalities are demonstrated. PMID:26839036
NASA Astrophysics Data System (ADS)
Mikolajick, T.; Heinzig, A.; Trommer, J.; Baldauf, T.; Weber, W. M.
2017-04-01
With CMOS scaling reaching physical limits in the next decade, new approaches are required to enhance the functionality of electronic systems. Reconfigurability on the device level promises to realize more complex systems with a lower device count. In the last five years a number of interesting concepts have been proposed to realize such a device level reconfiguration. Among these the reconfigurable field effect transistor (RFET), a device that can be configured between an n-channel and p-channel behavior by applying an electrical signal, can be considered as an end-of-roadmap extension of current technology with only small modifications and even simplifications to the process flow. This article gives a review on the RFET basics and current status. In the first sections state-of-the-art of reconfigurable devices will be summarized and the RFET will be introduced together with related devices based on silicon nanowire technology. The device optimization with respect to device symmetry and performance will be discussed next. The potential of the RFET device technology will then be shown by discussing selected circuit implementations making use of the unique advantages of this device concept. The basic device concept was also extended towards applications in flexible devices and sensors, also extending the capabilities towards so-called More-than-Moore applications where new functionalities are implemented in CMOS-based processes. Finally, the prospects of RFET device technology will be discussed.
Creating a systems engineering approach for the manual on uniform traffic control devices.
DOT National Transportation Integrated Search
2011-03-01
The Manual on Uniform Traffic Control Devices (MUTCD) provides basic principles for use of traffic : control devices (TCD). However, most TCDs are not explicitly required, and the decision to use a given : TCD in a given situation is typically made b...
ERIC Educational Resources Information Center
Rutgers, The State Univ., New Brunswick, NJ. Bureau of Economic Research.
The directory provides basic information about programs that purchase, finance, or lend devices for deaf and hard-of-hearing people. Only devices that make use of senses other than hearing (e.g., telecommunication devices for the deaf (TDD), closed caption television decoders, and flashing signal systems) are covered, and most devices cost less…
Tunnel transit-time (TUNNETT) devices for terahertz sources
NASA Technical Reports Server (NTRS)
Haddad, G. I.; East, J. R.; Kidner, C.
1991-01-01
The potential and capabilities of tunnel transit-time (TUNNETT) devices for power generation in the 100-1000 GHz range are presented. The basic properties of these devices and the important material parameters which determine their properties are discussed and criteria for designing such devices are presented. It is shown from a first-order model that significant amounts of power can be obtained from these devices in the terahertz frequency range.
Engineering Design Handbook. Propellant Actuated Devices.
1975-09-30
DA 016 716 ENGINEERING DESIGN HANDBOOK PROPELLANT ACTUATED DEVICES ARMY MATERIEL COMMAND ALEXANDRIA, VIRGINIA SEPTEMBER 1975 Best Available Copy... DESIGN HANDBOOK PROPELLANT ACTUATED DEVICES TABLE OF CONTENTS Paragraph Pae "LIST OF ILLUSTRATIONS .................. I LIST OF TABLES...Tramcmission in Systems ................. 2-18 References ............................... 2-18 CHAPTER 3. BASIC DESIGN CONSIDERATIONS 3-1 General
The upgraded Large Plasma Device, a machine for studying frontier basic plasma physics.
Gekelman, W; Pribyl, P; Lucky, Z; Drandell, M; Leneman, D; Maggs, J; Vincena, S; Van Compernolle, B; Tripathi, S K P; Morales, G; Carter, T A; Wang, Y; DeHaas, T
2016-02-01
In 1991 a manuscript describing an instrument for studying magnetized plasmas was published in this journal. The Large Plasma Device (LAPD) was upgraded in 2001 and has become a national user facility for the study of basic plasma physics. The upgrade as well as diagnostics introduced since then has significantly changed the capabilities of the device. All references to the machine still quote the original RSI paper, which at this time is not appropriate. In this work, the properties of the updated LAPD are presented. The strategy of the machine construction, the available diagnostics, the parameters available for experiments, as well as illustrations of several experiments are presented here.
Synaptic electronics: materials, devices and applications.
Kuzum, Duygu; Yu, Shimeng; Wong, H-S Philip
2013-09-27
In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented.
Progress on Electronic and Optoelectronic Devices of 2D Layered Semiconducting Materials.
Wang, Feng; Wang, Zhenxing; Jiang, Chao; Yin, Lei; Cheng, Ruiqing; Zhan, Xueying; Xu, Kai; Wang, Fengmei; Zhang, Yu; He, Jun
2017-09-01
2D layered semiconducting materials (2DLSMs) represent the thinnest semiconductors, holding many novel properties, such as the absence of surface dangling bonds, sizable band gaps, high flexibility, and ability of artificial assembly. With the prospect of bringing revolutionary opportunities for electronic and optoelectronic applications, 2DLSMs have prospered over the past twelve years. From materials preparation and property exploration to device applications, 2DLSMs have been extensively investigated and have achieved great progress. However, there are still great challenges for high-performance devices. In this review, we provide a brief overview on the recent breakthroughs in device optimization based on 2DLSMs, particularly focussing on three aspects: device configurations, basic properties of channel materials, and heterostructures. The effects from device configurations, i.e., electrical contacts, dielectric layers, channel length, and substrates, are discussed. After that, the affect of the basic properties of 2DLSMs on device performance is summarized, including crystal defects, crystal symmetry, doping, and thickness. Finally, we focus on heterostructures based on 2DLSMs. Through this review, we try to provide a guide to improve electronic and optoelectronic devices of 2DLSMs for achieving practical device applications in the future. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGoldrick, P.R.; Allison, T.G.
The BASIC2 INTERPRETER was developed to provide a high-level easy-to-use language for performing both control and computational functions in the MCS-80. The package is supplied as two alternative implementations, hardware and software. The ''software'' implementation provides the following capabilities: entry and editing of BASIC programs, device-independent I/O, special functions to allow access from BASIC to any I/O port, formatted printing, special INPUT/OUTPUT-and-proceed statements to allow I/O without interrupting BASIC program execution, full arithmetic expressions, limited string manipulation (10 or fewer characters), shorthand forms for common BASIC keywords, immediate mode BASIC statement execution, and capability of running a BASIC program thatmore » is stored in PROM. The allowed arithmetic operations are addition, subtraction, multiplication, division, and raising a number to a positive integral power. In the second, or ''hardware'', implementation of BASIC2 requiring an Am9511 Arithmetic Processing Unit (APU) interfaced to the 8080 microprocessor, arithmetic operations are performed by the APU. The following additional built-in functions are available in this implementation: square root, sine, cosine, tangent, arcsine, arccosine, arctangent, exponential, logarithm base e, and logarithm base 10. MCS-80,8080-based microcomputers; 8080 Assembly language; Approximately 8K bytes of RAM to store the assembled interpreter, additional user program space, and necessary peripheral devices. The hardware implementation requires an Am9511 Arithmetic Processing Unit and an interface board (reference 2).« less
Evaluating the ergonomics of BCI devices for research and experimentation.
Ekandem, Joshua I; Davis, Timothy A; Alvarez, Ignacio; James, Melva T; Gilbert, Juan E
2012-01-01
The use of brain computer interface (BCI) devices in research and applications has exploded in recent years. Applications such as lie detectors that use functional magnetic resonance imaging (fMRI) to video games controlled using electroencephalography (EEG) are currently in use. These developments, coupled with the emergence of inexpensive commercial BCI headsets, such as the Emotiv EPOC ( http://emotiv.com/index.php ) and the Neurosky MindWave, have also highlighted the need of performing basic ergonomics research since such devices have usability issues, such as comfort during prolonged use, and reduced performance for individuals with common physical attributes, such as long or coarse hair. This paper examines the feasibility of using consumer BCIs in scientific research. In particular, we compare user comfort, experiment preparation time, signal reliability and ease of use in light of individual differences among subjects for two commercially available hardware devices, the Emotiv EPOC and the Neurosky MindWave. Based on these results, we suggest some basic considerations for selecting a commercial BCI for research and experimentation. STATEMENT OF RELEVANCE: Despite increased usage, few studies have examined the usability of commercial BCI hardware. This study assesses usability and experimentation factors of two commercial BCI models, for the purpose of creating basic guidelines for increased usability. Finding that more sensors can be less comfortable and accurate than devices with fewer sensors.
A simple and inexpensive pulsing device for data-recording cameras
David L. Sonderman
1973-01-01
In some areas of forestry and wood utilization research, use of automatic data recording equipment has become commonplace. This research note describes the basic electronic components needed to modify an existing intervalometer into a simplified pulsing device for controlling an automatic data recording camera. The pulsing device is easily assembled and inexpensive,...
ERIC Educational Resources Information Center
Evanson, Nick
2004-01-01
Basic electronic devices have been used to great effect with console computer games. This paper looks at a range of devices from the very simple, such as microswitches and potentiometers, up to the more complex Hall effect probe. There is a great deal of relatively straightforward use of simple devices in computer games systems, and having read…
Tactile Speech Indicator: Adaptive Telephone Device for Deaf-Blind Clients.
ERIC Educational Resources Information Center
Lynch, M. R.
1990-01-01
This article describes basic applications of an adaptive telephone device for deaf-blind persons with speaking voices. The deaf-blind caller poses questions requiring one-word answers, and the device vibrates in response to touch-tone pulses from the other party. Specific suggestions for such uses as making appointments and emergency calls are…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-20
... NUCLEAR REGULATORY COMMISSION [NRC-2013-0098] Embedded Digital Devices in Safety-Related Systems... (NRC) is issuing for public comment Draft Regulatory Issue Summary (RIS) 2013-XX, ``Embedded Digital... requirements for the quality and reliability of basic components with embedded digital devices. DATES: Submit...
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
System Architectural Concepts: Army Battlefield Command and Control Information Utility (CCIU).
1982-07-25
produce (device-type), the computers they may interface with (required- host), and the identification number of the devices (device- number). Line- printers ...interface in a network PE ( ZINK Sol. A-5 GLOSSARY Kernel A layer of the PEOS; implements the basic system primitives. LUS Local Name Space Locking A
A tandem mirror plasma source for hybrid plume plasma studies
NASA Technical Reports Server (NTRS)
Yang, T. F.; Chang, F. R.; Miller, R. H.; Wenzel, K. W.; Krueger, W. A.
1985-01-01
A tandem mirror device to be considered as a hot plasma source for the hybrid plume rocket concept is discussed. The hot plamsa from this device is injected into an exhaust duct, which will interact with an annular hypersonic layer of neutral gas. The device can be used to study the dynamics of the hybrid plume, and to verify the numerical predictions obtained with computer codes. The basic system design is also geared towards low weight and compactness, and high power density at the exhaust. The basic structure of the device consists of four major subsystems: (1) an electric power supply; (2) a low temperature, high density plasma gun, such as a stream gun, an MPD source or gas cell; (3) a power booster in the form of a tandem mirror machine; and (4) an exhaust nozzle arrangement. The configuration of the tandem mirror section is shown.
[Microcomputer control of a LED stimulus display device].
Ohmoto, S; Kikuchi, T; Kumada, T
1987-02-01
A visual stimulus display system controlled by a microcomputer was constructed at low cost. The system consists of a LED stimulus display device, a microcomputer, two interface boards, a pointing device (a "mouse") and two kinds of software. The first software package is written in BASIC. Its functions are: to construct stimulus patterns using the mouse, to construct letter patterns (alphabet, digit, symbols and Japanese letters--kanji, hiragana, katakana), to modify the patterns, to store the patterns on a floppy disc, to translate the patterns into integer data which are used to display the patterns in the second software. The second software package, written in BASIC and machine language, controls display of a sequence of stimulus patterns in predetermined time schedules in visual experiments.
A Review of the Use of Touch-Screen Mobile Devices by People with Developmental Disabilities
ERIC Educational Resources Information Center
Stephenson, Jennifer; Limbrick, Lisa
2015-01-01
This article presents a review of the research on the use of mobile touch-screen devices such as PDAs, iPod Touches, iPads and smart phones by people with developmental disabilities. Most of the research has been on very basic use of the devices as speech generating devices, as a means of providing video, pictorial and/or audio self-prompting and…
Manually operated elastomer heat pump
NASA Technical Reports Server (NTRS)
Hutchinson, W. D.
1970-01-01
Device consisting of a rotating mechanism, a frame with multiple wide bands of rubber, and a fluid bath, demonstrates the feasibility of a human operated device capable of cooling or producing heat. This invention utilizes the basic thermodynamic properties of natural rubber.
49 CFR 236.1043 - Task analysis and basic requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Positive Train Control Systems § 236.1043 Task analysis and basic requirements. (a) Training structure and... installation, maintenance, repair, modification, inspection, testing, and operating tasks that must be...
49 CFR 236.1043 - Task analysis and basic requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Positive Train Control Systems § 236.1043 Task analysis and basic requirements. (a) Training structure and... installation, maintenance, repair, modification, inspection, testing, and operating tasks that must be...
49 CFR 236.1043 - Task analysis and basic requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Positive Train Control Systems § 236.1043 Task analysis and basic requirements. (a) Training structure and... installation, maintenance, repair, modification, inspection, testing, and operating tasks that must be...
49 CFR 236.1043 - Task analysis and basic requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Positive Train Control Systems § 236.1043 Task analysis and basic requirements. (a) Training structure and... installation, maintenance, repair, modification, inspection, testing, and operating tasks that must be...
49 CFR 236.1043 - Task analysis and basic requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Positive Train Control Systems § 236.1043 Task analysis and basic requirements. (a) Training structure and... installation, maintenance, repair, modification, inspection, testing, and operating tasks that must be...
Modeling Self-Heating Effects in Nanoscale Devices
NASA Astrophysics Data System (ADS)
Raleva, K.; Shaik, A. R.; Vasileska, D.; Goodnick, S. M.
2017-08-01
Accurate thermal modeling and the design of microelectronic devices and thin film structures at the micro- and nanoscales poses a challenge to electrical engineers who are less familiar with the basic concepts and ideas in sub-continuum heat transport. This book aims to bridge that gap. Efficient heat removal methods are necessary to increase device performance and device reliability. The authors provide readers with a combination of nanoscale experimental techniques and accurate modeling methods that must be employed in order to determine a device's temperature profile.
Device Management and Flow Optimization on Left Ventricular Assist Device Support.
Tchoukina, Inna; Smallfield, Melissa C; Shah, Keyur B
2018-07-01
The authors discuss principles of continuous flow left ventricular assist device (LVAD) operation, basic differences between the axial and centrifugal flow designs and hemodynamic performance, normal LVAD physiology, and device interaction with the heart. Systematic interpretation of LVAD parameters and recognition of abnormal patterns of flow and pulsatility on the device interrogation are necessary for clinical assessment of the patient. Optimization of pump flow using LVAD parameters and echocardiographic and hemodynamics guidance are reviewed. Copyright © 2018 Elsevier Inc. All rights reserved.
Main devices design of submarine oil-water separation system
NASA Astrophysics Data System (ADS)
Cai, Wen-Bin; Liu, Bo-Hong
2017-11-01
In the process of offshore oil production, in order to thoroughly separate oil from produced fluid, solve the environment problem caused by oily sewage, and improve the economic benefit of offshore drilling, from the perspective of new oil-water separation, a set of submarine oil-water separation devices were designed through adsorption and desorption mechanism of the polymer materials for crude oil in this paper. The paper introduces the basic structure of gas-solid separation device, periodic separation device and adsorption device, and proves the rationality and feasibility of this device.
Properties of the ion-ion hybrid resonator in fusion plasmas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morales, George J.
2015-10-06
The project developed theoretical and numerical descriptions of the properties of ion-ion hybrid Alfvén resonators that are expected to arise in the operation of a fusion reactor. The methodology and theoretical concepts were successfully compared to observations made in basic experiments in the LAPD device at UCLA. An assessment was made of the excitation of resonator modes by energetic alpha particles for burning plasma conditions expected in the ITER device. The broader impacts included the generation of basic insight useful to magnetic fusion and space science researchers, defining new avenues for exploration in basic laboratory experiments, establishing broader contacts betweenmore » experimentalists and theoreticians, completion of a Ph.D. dissertation, and promotion of interest in science through community outreach events and classroom instruction.« less
Very-large-area CCD image sensors: concept and cost-effective research
NASA Astrophysics Data System (ADS)
Bogaart, E. W.; Peters, I. M.; Kleimann, A. C.; Manoury, E. J. P.; Klaassens, W.; de Laat, W. T. F. M.; Draijer, C.; Frost, R.; Bosiers, J. T.
2009-01-01
A new-generation full-frame 36x48 mm2 48Mp CCD image sensor with vertical anti-blooming for professional digital still camera applications is developed by means of the so-called building block concept. The 48Mp devices are formed by stitching 1kx1k building blocks with 6.0 µm pixel pitch in 6x8 (hxv) format. This concept allows us to design four large-area (48Mp) and sixty-two basic (1Mp) devices per 6" wafer. The basic image sensor is relatively small in order to obtain data from many devices. Evaluation of the basic parameters such as the image pixel and on-chip amplifier provides us statistical data using a limited number of wafers. Whereas the large-area devices are evaluated for aspects typical to large-sensor operation and performance, such as the charge transport efficiency. Combined with the usability of multi-layer reticles, the sensor development is cost effective for prototyping. Optimisation of the sensor design and technology has resulted in a pixel charge capacity of 58 ke- and significantly reduced readout noise (12 electrons at 25 MHz pixel rate, after CDS). Hence, a dynamic range of 73 dB is obtained. Microlens and stack optimisation resulted in an excellent angular response that meets with the wide-angle photography demands.
[Improved device and method for determination of protein digestibility in vitro].
Lipatov, N N; Iudina, S B; Lisitsyn, A B
1994-01-01
The ten-cells device for modelling of ferment hydrolysis of food proteins by acid basic proteases of human alimentary canal is described. The new procedure for the calculation of quantitative characteristic of proteins digestion "in vitro" is presented.
Basic Weather Facts Study Texts for Students.
ERIC Educational Resources Information Center
Ontario Ministry of the Environment, Toronto.
This pamphlet offers information to teachers and students concerning basic facts about weather and how to construct simple weather measurement devices. Directions, necessary materials, procedures, and instructions for use are given for four weather predicting instruments: wind vane, rain gauge, barometer, anemometer. Information is provided on…
ERIC Educational Resources Information Center
Willison, Neal A.; Shelton, James K.
Designed for use in basic electronics programs, this curriculum guide is comprised of 15 units of instruction. Unit titles are Review of the Nature of Matter and the P-N Junction, Rectifiers, Filters, Special Semiconductor Diodes, Bipolar-Junction Diodes, Bipolar Transistor Circuits, Transistor Amplifiers, Operational Amplifiers, Logic Devices,…
Radiological Dispersion Devices and Basic Radiation Science
NASA Astrophysics Data System (ADS)
Bevelacqua, Joseph John
2010-05-01
Introductory physics courses present the basic concepts of radioactivity and an overview of nuclear physics that emphasizes the basic decay relationship and the various types of emitted radiation. Although this presentation provides insight into radiological science, it often fails to interest students to explore these concepts in a more rigorous manner. One reason for limited student interest is the failure to link the discussion to topics of current interest. The author has found that presenting this material with a link to radiological dispersion devices (RDDs), or dirty bombs, and their associated health effects provides added motivation for students. The events of Sept. 11, 2001, and periodic media focus on RDDs heighten student interest from both a scientific curiosity as well as a personal protection perspective. This article presents a framework for a more interesting discussion of the basics of radiation science and their associated health effects. The presentation can be integrated with existing radioactivity lectures or added as a supplementary or enrichment activity.
NASA Astrophysics Data System (ADS)
Avino, Fabio; Bovet, Alexandre; Fasoli, Ambrogio; Furno, Ivo; Gustafson, Kyle; Loizu, Joaquim; Ricci, Paolo; Theiler, Christian
2012-10-01
TORPEX is a basic plasma physics toroidal device located at the CRPP-EPFL in Lausanne. In TORPEX, a vertical magnetic field superposed on a toroidal field creates helicoidal field lines with both ends terminating on the torus vessel. We review recent advances in the understanding and control of electrostatic interchange turbulence, associated structures and their effect on suprathermal ions. These advances are obtained using high-resolution diagnostics of plasma parameters and wave fields throughout the whole device cross-section, fluid models and numerical simulations. Furthermore, we discuss future developments including the possibility of generating closed field line configurations with rotational transform using an internal toroidal wire carrying a current. This system will also allow the study of innovative fusion-relevant configurations, such as the snowflake divertor.
The foreign body response: at the interface of surgery and bioengineering.
Major, Melanie R; Wong, Victor W; Nelson, Emily R; Longaker, Michael T; Gurtner, Geoffrey C
2015-05-01
The surgical implantation of materials and devices has dramatically increased over the past decade. This trend is expected to continue with the broadening application of biomaterials and rapid expansion of aging populations. One major factor that limits the potential of implantable materials and devices is the foreign body response, an immunologic reaction characterized by chronic inflammation, foreign body giant cell formation, and fibrotic capsule formation. The English literature on the foreign body response to implanted materials and devices is reviewed. Fibrotic encapsulation can cause device malfunction and dramatically limit the function of an implanted medical device or material. Basic science studies suggest a role for immune and inflammatory pathways at the implant-host interface that drive the foreign body response. Current strategies that aim to modulate the host response and improve construct biocompatibility appear promising. This review article summarizes recent basic science, preclinical, and clinicopathologic studies examining the mechanisms driving the foreign body response, with particular focus on breast implants and synthetic meshes. Understanding these molecular and cellular mechanisms will be critical for achieving the full potential of implanted biomaterials to restore human tissues and organs.
The HelCat basic plasma science device
NASA Astrophysics Data System (ADS)
Gilmore, M.; Lynn, A. G.; Desjardins, T. R.; Zhang, Y.; Watts, C.; Hsu, S. C.; Betts, S.; Kelly, R.; Schamiloglu, E.
2015-01-01
The Helicon-Cathode(HelCat) device is a medium-size linear experiment suitable for a wide range of basic plasma science experiments in areas such as electrostatic turbulence and transport, magnetic relaxation, and high power microwave (HPM)-plasma interactions. The HelCat device is based on dual plasma sources located at opposite ends of the 4 m long vacuum chamber - an RF helicon source at one end and a thermionic cathode at the other. Thirteen coils provide an axial magnetic field B >= 0.220 T that can be configured individually to give various magnetic configurations (e.g. solenoid, mirror, cusp). Additional plasma sources, such as a compact coaxial plasma gun, are also utilized in some experiments, and can be located either along the chamber for perpendicular (to the background magnetic field) plasma injection, or at one of the ends for parallel injection. Using the multiple plasma sources, a wide range of plasma parameters can be obtained. Here, the HelCat device is described in detail and some examples of results from previous and ongoing experiments are given. Additionally, examples of planned experiments and device modifications are also discussed.
A comparison of optical gradation analysis devices to current test methods--phase 2.
DOT National Transportation Integrated Search
2012-04-01
Optical devices are being developed to deliver accurate size and shape of aggregate particles with, less labor, less consistency error, : and greater reliability. This study was initiated to review the existing technology, and generate basic data to ...
[Support devices for the prevention and treatment of pressure sores].
Perrouin-Verbe, Brigite
2014-12-01
There is a strategy to be followed in the treatment of patients with specific pathologies placing them at high risk of pressure sores. In some cases, sophisticated support devices are used.These techniques must be combined with basic good practices.
Development of Mathematical Skills Developing Game Software.
Hajdics, Gyula; Guzsvinecz, Tibor; Szucs, Veronika; Sik Lanyi, Cecilia
2017-01-01
Using basic mathematical operations is not easy for everyone. The AndMaths game for Android devices was developed to help elementary school students to learn these basic mathematical skills in the number ranges of twenties, fifties, hundreds and thousands. The user can freely select the number ranges.
49 CFR 236.923 - Task analysis and basic requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Standards for Processor-Based Signal and Train Control Systems § 236.923 Task analysis and basic requirements..., inspection, testing, and operating tasks that must be performed on a railroad's products. This includes the...
49 CFR 236.923 - Task analysis and basic requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Standards for Processor-Based Signal and Train Control Systems § 236.923 Task analysis and basic requirements..., inspection, testing, and operating tasks that must be performed on a railroad's products. This includes the...
49 CFR 236.923 - Task analysis and basic requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Standards for Processor-Based Signal and Train Control Systems § 236.923 Task analysis and basic requirements..., inspection, testing, and operating tasks that must be performed on a railroad's products. This includes the...
49 CFR 236.923 - Task analysis and basic requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Standards for Processor-Based Signal and Train Control Systems § 236.923 Task analysis and basic requirements..., inspection, testing, and operating tasks that must be performed on a railroad's products. This includes the...
3D Printed "Earable" Smart Devices for Real-Time Detection of Core Body Temperature.
Ota, Hiroki; Chao, Minghan; Gao, Yuji; Wu, Eric; Tai, Li-Chia; Chen, Kevin; Matsuoka, Yasutomo; Iwai, Kosuke; Fahad, Hossain M; Gao, Wei; Nyein, Hnin Yin Yin; Lin, Liwei; Javey, Ali
2017-07-28
Real-time detection of basic physiological parameters such as blood pressure and heart rate is an important target in wearable smart devices for healthcare. Among these, the core body temperature is one of the most important basic medical indicators of fever, insomnia, fatigue, metabolic functionality, and depression. However, traditional wearable temperature sensors are based upon the measurement of skin temperature, which can vary dramatically from the true core body temperature. Here, we demonstrate a three-dimensional (3D) printed wearable "earable" smart device that is designed to be worn on the ear to track core body temperature from the tympanic membrane (i.e., ear drum) based on an infrared sensor. The device is fully integrated with data processing circuits and a wireless module for standalone functionality. Using this smart earable device, we demonstrate that the core body temperature can be accurately monitored regardless of the environment and activity of the user. In addition, a microphone and actuator are also integrated so that the device can also function as a bone conduction hearing aid. Using 3D printing as the fabrication method enables the device to be customized for the wearer for more personalized healthcare. This smart device provides an important advance in realizing personalized health care by enabling real-time monitoring of one of the most important medical parameters, core body temperature, employed in preliminary medical screening tests.
Transparent Conducting Oxides: Status and Opportunities in Basic Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coutts, T. J.; Perkins, J. D.; Ginley, D.S.
1999-08-01
In this paper, we begin by discussing the historical background of transparent conducting oxides and then make some general remarks about their typical properties. This is followed by a short discussion of the desired properties for future applications (particularly photovoltaic devices). These are ambitious objectives but they provide targets for future basic research and development. Although it may be possible to obtain these properties in the laboratory, it is vital to ensure that account is taken of industrial perceptions to the development of the next generation of materials. Hence, we spend some time discussing industrial criteria. Next, we discuss keymore » physical properties that determine the macroscopic physical properties that, in turn, affect the performance of devices. Finally, we select several key topics that ought to be included in future basic research programs.« less
San Diego field operational test of smart call boxes : technical aspects
DOT National Transportation Integrated Search
1997-01-01
Smart call boxes are devices similar to those used as emergency call boxes in California. The basic call box consists of a microprocessor, a cellular transceiver, and a solar power source. The smart call box system also includes data-collection devic...
SPILL ALERT DEVICE FOR EARTH DAM FAILURE WARNING
A spill alert device for determining earth dam safety based on the monitoring of the acoustic emissions generated in a deforming soil mass was developed and field-tested. The acoustic emissions are related to the basic mechanisms from which soils derive their strength. Laboratory...
NASA Technical Reports Server (NTRS)
Katti, Romney R.
1995-01-01
Random-access memory (RAM) devices of proposed type exploit magneto-optical properties of magnetic garnets exhibiting perpendicular anisotropy. Magnetic writing and optical readout used. Provides nonvolatile storage and resists damage by ionizing radiation. Because of basic architecture and pinout requirements, most likely useful as small-capacity memory devices.
Neurophysiology and neural engineering: a review.
Prochazka, Arthur
2017-08-01
Neurophysiology is the branch of physiology concerned with understanding the function of neural systems. Neural engineering (also known as neuroengineering) is a discipline within biomedical engineering that uses engineering techniques to understand, repair, replace, enhance, or otherwise exploit the properties and functions of neural systems. In most cases neural engineering involves the development of an interface between electronic devices and living neural tissue. This review describes the origins of neural engineering, the explosive development of methods and devices commencing in the late 1950s, and the present-day devices that have resulted. The barriers to interfacing electronic devices with living neural tissues are many and varied, and consequently there have been numerous stops and starts along the way. Representative examples are discussed. None of this could have happened without a basic understanding of the relevant neurophysiology. I also consider examples of how neural engineering is repaying the debt to basic neurophysiology with new knowledge and insight. Copyright © 2017 the American Physiological Society.
Physical layer simulation study for the coexistence of WLAN standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howlader, M. K.; Keiger, C.; Ewing, P. D.
This paper presents the results of a study on the performance of wireless local area network (WLAN) devices in the presence of interference from other wireless devices. To understand the coexistence of these wireless protocols, simplified physical-layer-system models were developed for the Bluetooth, Wireless Fidelity (WiFi), and Zigbee devices, all of which operate within the 2.4-GHz frequency band. The performances of these protocols were evaluated using Monte-Carlo simulations under various interference and channel conditions. The channel models considered were basic additive white Gaussian noise (AWGN), Rayleigh fading, and site-specific fading. The study also incorporated the basic modulation schemes, multiple accessmore » techniques, and channel allocations of the three protocols. This research is helping the U.S. Nuclear Regulatory Commission (NRC) understand the coexistence issues associated with deploying wireless devices and could prove useful in the development of a technical basis for guidance to address safety-related issues with the implementation of wireless systems in nuclear facilities. (authors)« less
Study on development of active-passive rehabilitation system for upper limbs: Hybrid-PLEMO
NASA Astrophysics Data System (ADS)
Kikuchi, T.; Jin, Y.; Fukushima, K.; Akai, H.; Furusho, J.
2009-02-01
In recent years, many researchers have studied the potential of using robotics technology to assist and quantify the motor functions for neuron-rehabilitation. Some kinds of haptic devices have been developed and evaluated its efficiency with clinical tests, for example, upper limb training for patients with spasticity after stroke. Active-type (motor-driven) haptic devices can realize a lot of varieties of haptics. But they basically require high-cost safety system. On the other hand, passive-type (brake-based) haptic devices have inherent safety. However, the passive robot system has strong limitation on varieties of haptics. There are not sufficient evidences to clarify how the passive/active haptics effect to the rehabilitation of motor skills. In this paper, we developed an active-passive-switchable rehabilitation system with ER clutch/brake device named "Hybrid-PLEMO" in order to address these problems. In this paper, basic structures and haptic control methods of the Hybrid-PLEMO are described.
ERIC Educational Resources Information Center
Fisher, Patience; And Others
This guide was prepared to help teachers of the Lincoln Public School's introductory computer programming course in BASIC to make the necessary adjustments for changes made in the course since the purchase of microcomputers and such peripheral devices as television monitors and disk drives, and the addition of graphics. Intended to teach a…
Basics of Videodisc and Optical Disk Technology.
ERIC Educational Resources Information Center
Paris, Judith
1983-01-01
Outlines basic videodisc and optical disk technology describing both optical and capacitance videodisc technology. Optical disk technology is defined as a mass digital image and data storage device and briefly compared with other information storage media including magnetic tape and microforms. The future of videodisc and optical disk is…
2002-12-01
An operating room (OR) automation system is a combination of hardware and software designed to address efficiency issues in the OR by controling multiple devices via a common interface. Systems range from the relatively basic--allowing control of a few devices within a single OR--to advanced designs that are capable of not only controlling a wide range of devices within the OR but also exchanging information with remote locations.
Classroom-sized geophysical experiments: magnetic surveying using modern smartphone devices
NASA Astrophysics Data System (ADS)
Tronicke, Jens; Trauth, Martin H.
2018-05-01
Modern mobile devices (i.e. smartphones and tablet computers) are widespread, everyday tools, which are equipped with a variety of sensors including three-axis magnetometers. Here, we investigate the feasibility and the potential of using such mobile devices to mimic geophysical experiments in the classroom in a table-top setup. We focus on magnetic surveying and present a basic setup of a table-top experiment for collecting three-component magnetic data across well-defined source bodies and structures. Our results demonstrate that the quality of the recorded data is sufficient to address a number of important basic concepts in the magnetic method. The shown examples cover the analysis of magnetic data recorded across different kinds of dipole sources, thus illustrating the complexity of magnetic anomalies. In addition, we analyze the horizontal resolution capabilities using a pair of dipole sources placed at different horizontal distances to each other. Furthermore, we demonstrate that magnetic data recorded with a mobile device can even be used to introduce filtering, transformation, and inversion approaches as they are typically used when processing magnetic data sets recorded for real-world field applications. Thus, we conclude that such table-top experiments represent an easy-to-implement experimental procedure (as student exercise or classroom demonstration) and can provide first hands-on experience in the basic principles of magnetic surveying including the fundamentals of data acquisition, analysis and processing, as well as data evaluation and interpretation.
NASA Astrophysics Data System (ADS)
Li, Hao; Liu, Jianshe; Zhang, Yingshan; Cai, Han; Li, Gang; Liu, Qichun; Han, Siyuan; Chen, Wei
2017-03-01
A negative-inductance superconducting quantum interference device (nSQUID) is an adiabatic superconducting logic device with high energy efficiency, and therefore a promising building block for large-scale low-power superconducting computing. However, the principle of the nSQUID is not that straightforward and an nSQUID driven by voltage is vulnerable to common mode noise. We investigate a single nSQUID driven by current instead of voltage, and clarify the principle of the adiabatic transition of the current-driven nSQUID between different states. The basic logic operations of the current-driven nSQUID with proper parameters are simulated by WRspice. The corresponding circuit is fabricated with a 100 A cm-2 Nb-based lift-off process, and the experimental results at low temperature confirm the basic logic operations as a gated buffer.
NASA Astrophysics Data System (ADS)
Cardall, Christian Y.; Budiardja, Reuben D.
2017-05-01
GenASiS Basics provides Fortran 2003 classes furnishing extensible object-oriented utilitarian functionality for large-scale physics simulations on distributed memory supercomputers. This functionality includes physical units and constants; display to the screen or standard output device; message passing; I/O to disk; and runtime parameter management and usage statistics. This revision -Version 2 of Basics - makes mostly minor additions to functionality and includes some simplifying name changes.
1985-12-01
development of an improved Universal Network Interface Device (UNID II). The UNID II’s architecture was based on a preliminary design project at...interface device, performing all functions required ,: the multi-ring LAN. The device depicted by RADC’s studies would connect a highly variable group of host...used the ISO Open Systems Ilterconnection (OSI) seven layer model as the basic structure for data flow and program development . In 1982 Cuomo
Emergency Vehicle Alarm System for Deaf Drivers by Using LEDs and Vibration Devices
NASA Astrophysics Data System (ADS)
Kuwahara, Noriaki; Morimoto, Kazunari; Kozuki, Kazumasa; Kawamura, Tomonori
We are developing the emergency vehicle alarm system for deaf drivers by using LEDs and vibration devices. In order to design the alarm for deaf drivers, we have conducted basic experiment in order to evaluate perceptual characteristic on visibility of LED.
NASA Astrophysics Data System (ADS)
Gurova, E. G.
2016-08-01
During the researches the mathematical description of the traction characteristics of the stiffness compensators of the vibration isolation devices, relatively of the each axis, has been done. Representation of the compensators properties considers the variable load, thereby provide the wide enough spectrum of the action of the suggested vibration isolators. The derived expressions are valid for all three axes of space at the different stiffnesses, i.e. basic basic and two compensating. The research was supported by the scholarships of Russian Federation President for young scientists №184 from 10th of March 2015.
Basics of Lasers: History, Physics, and Clinical Applications.
Franck, Philipp; Henderson, Peter W; Rothaus, Kenneth O
2016-07-01
Lasers are increasingly used by plastic surgeons to address issues such as wrinkles and textural changes, skin laxity, hyperpigmentation, vascularity, and excess fat accumulation. A fundamental understanding of the underlying science and physics of laser technology is important for the safe and efficacious use of laser in medical settings. The purpose of this article was to give clinicians with limited exposure to lasers a basic understanding of the underlying science. In that manner, they can confidently make appropriate decisions as to the best device to use on a patient (or the best device to purchase for a practice). Copyright © 2016 Elsevier Inc. All rights reserved.
Huang, Wei Tao; Luo, Hong Qun; Li, Nian Bing
2014-05-06
The most serious, and yet unsolved, problem of constructing molecular computing devices consists in connecting all of these molecular events into a usable device. This report demonstrates the use of Boolean logic tree for analyzing the chemical event network based on graphene, organic dye, thrombin aptamer, and Fenton reaction, organizing and connecting these basic chemical events. And this chemical event network can be utilized to implement fluorescent combinatorial logic (including basic logic gates and complex integrated logic circuits) and fuzzy logic computing. On the basis of the Boolean logic tree analysis and logic computing, these basic chemical events can be considered as programmable "words" and chemical interactions as "syntax" logic rules to construct molecular search engine for performing intelligent molecular search query. Our approach is helpful in developing the advanced logic program based on molecules for application in biosensing, nanotechnology, and drug delivery.
Naval Training Device Center Index of Technical Reports.
ERIC Educational Resources Information Center
Walker, Lemuel E.
Published Naval Training Device Center technical reports and some technical notes (those available through the Defense Documentation Center-DDC) which have resulted from basic research, exploratory development, and advanced development type projects are listed. The reports are indexed by technical note number, by title, and by contractor code. The…
A Signalling Device for Non-Oral Communicators.
ERIC Educational Resources Information Center
King, Thomas W.
1991-01-01
This article describes simple modifications to a basic 9-volt portable transistor radio to serve as a durable, inexpensive signalling device operable by a single external switch. The unit still functions as a radio, but can also help partially speaking students and users of communication aids to signal for help. (Author/PB)
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-12
...-Based Professional Subscriber Fees Charged by OPRA for its Basic Service November 8, 2010. Pursuant to... Options Last Sale Reports and Quotation Information (``OPRA Plan'').\\3\\ The proposed amendment would revise the device-based professional subscriber fees charged by OPRA in respect of its Basic Service. A...
Engineering of superconductors and superconducting devices using artificial pinning sites
NASA Astrophysics Data System (ADS)
Wördenweber, Roger
2017-08-01
Vortex matter in superconducting films and devices is not only an interesting topic for basic research but plays a substantial role in the applications of superconductivity in general. We demonstrate, that in most electronic applications, magnetic flux penetrates the superconductor and affects the performance of superconducting devices. Therefore, vortex manipulation turns out to be a useful tool to avoid degradation of superconducting device properties. Moreover, it can also be used to analyze and understand novel and interesting physical properties and develop new concepts for superconductor applications. In this review, various concepts for vortex manipulation are sketched. For example, the use of micro- and nanopatterns (especially, antidots) for guiding and trapping of vortices in superconducting films and thin film devices is discussed and experimental evidence of their vortex guidance and vortex trapping by various arrangements of antidots is given. We demonstrate, that the vortex state of matter is very important in applications of superconductivity. A better understanding does not only lead to an improvement of the performance of superconductor components, such as reduced noise, better power handling capability, or improved reliability, it also promises deeper insight into the basic physics of vortices and vortex matter.
2014-12-31
This final rule modifies the TRICARE regulation to add a definition of assistive technology (AT) devices for purposes of benefit coverage under the TRICARE Extended Care Health Option (ECHO) Program and to amend the definitions of durable equipment (DE) and durable medical equipment (DME) to better conform the language in the regulation to the statute. The final rule amends the language that specifically limits ordering or prescribing of DME to only a physician under the Basic Program, as this amendment will allow certain other TRICARE authorized individual professional providers, acting within the scope of their licensure, to order or prescribe DME. This final rule also incorporates a policy clarification relating to luxury, deluxe, or immaterial features of equipment or devices. That is, TRICARE cannot reimburse for the luxury, deluxe, or immaterial features of equipment or devices, but can reimburse for the base or basic equipment or device that meet the beneficiary's needs. Beneficiaries may choose to pay the provider for the luxury, deluxe, or immaterial features if they desire their equipment or device to have these "extra features."
Surface acoustic waves voltage controlled directional coupler
NASA Astrophysics Data System (ADS)
Golan, G.; Griffel, G.; Yanilov, E.; Ruschin, S.; Seidman, A.; Croitoru, N.
1988-10-01
An important condition for the development of surface wave integrated-acoustic devices is the ability to guide and control the propagation of the acoustic energy. This can be implemented by deposition of metallic "loading" channels on an anisotropic piezoelectric substrate. Deposition of such two parallel channels causes an effective coupling of acoustic energy from one channel to the other. A basic requirement for this coupling effect is the existence of the two basic modes: a symmetrical and a nonsymmetrical one. A mode map that shows the number of sustained modes as a function of the device parameters (i.e., channel width; distance between channels; material velocity; and acoustical exciting frequency) is presented. This kind of map can help significantly in the design process of such a device. In this paper we devise an advanced acoustical "Y" coupler with the ability to control its effective coupling by an externally applied voltage, thereby causing modulation of the output intensities of the signals.
Momen, Nausheen
2009-12-01
The use of computer-based, psychomotor testing systems for personnel selection and classification has gained popularity in the civilian and military worlds in recent years. However, several issues need to be resolved before adopting a computerized, psychomotor test. The purpose of this study was to compare the impact of alternative input devices used for the Test Of Basic Aviation Skills (TBAS) as well as to explore the practice effects of the TBAS. In study 1, participants were administered the TBAS tracking tests once with a throttle and once with foot pedals in a classic test-retest paradigm. The results confirmed that neither of the input devices provided a significant advantage on TBAS performance. In study 2, participants were administered the TBAS twice with a 24-hour interval between testing. The results demonstrated significant practice effects for all the TBAS subtests except for the dichotic listening tests.
Observation of turbulent-driven shear flow in a cylindrical laboratory plasma device.
Holland, C; Yu, J H; James, A; Nishijima, D; Shimada, M; Taheri, N; Tynan, G R
2006-05-19
An azimuthally symmetric radially sheared plasma fluid flow is observed to spontaneously form in a cylindrical magnetized helicon plasma device with no external sources of momentum input. A turbulent momentum conservation analysis shows that this shear flow is sustained by the Reynolds stress generated by collisional drift turbulence in the device. The results provide direct experimental support for the basic theoretical picture of drift-wave-shear-flow interactions.
System on Mobile Devices Middleware: Thinking beyond Basic Phones and PDAs
NASA Astrophysics Data System (ADS)
Prasad, Sushil K.
Several classes of emerging applications, spanning domains such as medical informatics, homeland security, mobile commerce, and scientific applications, are collaborative, and a significant portion of these will harness the capabilities of both the stable and mobile infrastructures (the “mobile grid”). Currently, it is possible to develop a collaborative application running on a collection of heterogeneous, possibly mobile, devices, each potentially hosting data stores, using existing middleware technologies such as JXTA, BREW, Compact .NET and J2ME. However, they require too many ad-hoc techniques as well as cumbersome and time-consuming programming. Our System on Mobile Devices (SyD) middleware, on the other hand, has a modular architecture that makes such application development very systematic and streamlined. The architecture supports transactions over mobile data stores, with a range of remote group invocation options and embedded interdependencies among such data store objects. The architecture further provides a persistent uniform object view, group transaction with Quality of Service (QoS) specifications, and XML vocabulary for inter-device communication. I will present the basic SyD concepts, introduce the architecture and the design of the SyD middleware and its components. We will discuss the basic performance figures of SyD components and a few SyD applications on PDAs. SyD platform has led to developments in distributed web service coordination and workflow technologies, which we will briefly discuss. There is a vital need to develop methodologies and systems to empower common users, such as computational scientists, for rapid development of such applications. Our BondFlow system enables rapid configuration and execution of workflows over web services. The small footprint of the system enables them to reside on Java-enabled handheld devices.
Using a software-defined computer in teaching the basics of computer architecture and operation
NASA Astrophysics Data System (ADS)
Kosowska, Julia; Mazur, Grzegorz
2017-08-01
The paper describes the concept and implementation of SDC_One software-defined computer designed for experimental and didactic purposes. Equipped with extensive hardware monitoring mechanisms, the device enables the students to monitor the computer's operation on bus transfer cycle or instruction cycle basis, providing the practical illustration of basic aspects of computer's operation. In the paper, we describe the hardware monitoring capabilities of SDC_One and some scenarios of using it in teaching the basics of computer architecture and microprocessor operation.
Mobile Technologies for the Surgical Pathologist.
Hartman, Douglas J
2015-06-01
Recent advances in hardware and computing power contained within mobile devices have made it possible to use these devices to improve and enhance pathologist workflow. This article discusses the possible uses ranging from basic functions to intermediate functions to advanced functions. Barriers to implementation are also discussed. Copyright © 2015 Elsevier Inc. All rights reserved.
A Field Exercise on Groundwater Flow Using Seepage Meters and Mini-Piezometers.
ERIC Educational Resources Information Center
Lee, David R.; Cherry, John A.
1979-01-01
Basic principles of physical hydrogeology and the nature of hydrologic interactions between groundwater and surface water can be demonstrated using two devices, the miniature piezometer and the seepage meter which can be cheaply constructed by the teacher and students. Use of the devices and learning activities are presented. (RE)
40 CFR 60.142 - Standard for particulate matter.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...
40 CFR 60.142 - Standard for particulate matter.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...
40 CFR 60.142 - Standard for particulate matter.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...
40 CFR 60.142 - Standard for particulate matter.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...
40 CFR 60.142 - Standard for particulate matter.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Emissions from Basic Oxygen Process Furnaces for Which Construction is Commenced After June 11, 1973 § 60... primary oxygen blow. (ii) Exit from a control device not used solely for the collection of secondary.../dscm (0.030 gr/dscf), as measured for the primary oxygen blow. (ii) Exit from a control device not used...
A Device to Demonstrate the Principles of Photometry and Three Experiments for Its Use.
ERIC Educational Resources Information Center
Delumyea, R. Del
1987-01-01
Describes how to construct a simple photometer. Outlines experiments in which this device can be used to demonstrate basic electronic principles, the use of Beer's Law to determine the concentration of an analyte in solution, and the effect of molar absorptivity on the sensitivity of photometric procedures. (TW)
Response to "Expanding Access to Learning with Mobile Digital Devices"
ERIC Educational Resources Information Center
Vanek, Jen
2017-01-01
In his article "Expanding Access to Learning with Mobile Digital Devices" (EJ1150752), Jeff Carter recommended a balanced perspective when measuring the potential of mobile learning to redefine teaching and learning for adults with basic skills needs. In response to Carter's article, the author makes some recommendations that she thinks…
Legislation and Equality in Basic Education for All in China
ERIC Educational Resources Information Center
Law, Wing-Wah; Pan, Su-Yan
2009-01-01
In China, legislation exists which requires compulsory schooling for all students of school age. This article examines the functions of and the constraints on using law to institutionalize equality in basic education. It argues that, in China, law is a last resort, holding governments of various levels accountable. Law can be a device of social…
A Mobile Computing Solution for Collecting Functional Analysis Data on a Pocket PC
ERIC Educational Resources Information Center
Jackson, James; Dixon, Mark R.
2007-01-01
The present paper provides a task analysis for creating a computerized data system using a Pocket PC and Microsoft Visual Basic. With Visual Basic software and any handheld device running the Windows MOBLE operating system, this task analysis will allow behavior analysts to program and customize their own functional analysis data-collection…
ERIC Educational Resources Information Center
Carangelo, Pasquale R.; Janeczek, Anthony J.
Materials are provided for a two-semester digital and microprocessor technician postgraduate program. Prerequisites stated for the program include a background in DC and AC theory, solid state devices, basic circuit fundamentals, and basic math. A chronology of major topics and a listing of course objectives appear first. Theory outlines for each…
Quantum-dot cellular automata: Review and recent experiments (invited)
NASA Astrophysics Data System (ADS)
Snider, G. L.; Orlov, A. O.; Amlani, I.; Zuo, X.; Bernstein, G. H.; Lent, C. S.; Merz, J. L.; Porod, W.
1999-04-01
An introduction to the operation of quantum-dot cellular automata is presented, along with recent experimental results. Quantum-dot cellular automata (QCA) is a transistorless computation paradigm that addresses the issues of device density and interconnection. The basic building blocks of the QCA architecture, such as AND, OR, and NOT are presented. The experimental device is a four-dot QCA cell with two electrometers. The dots are metal islands, which are coupled by capacitors and tunnel junctions. An improved design of the cell is presented in which all four dots of the cell are coupled by tunnel junctions. The operation of this basic cell is confirmed by the externally controlled polarization change of the cell.
Klatzky, Roberta L; Giudice, Nicholas A; Bennett, Christopher R; Loomis, Jack M
2014-01-01
Many developers wish to capitalize on touch-screen technology for developing aids for the blind, particularly by incorporating vibrotactile stimulation to convey patterns on their surfaces, which otherwise are featureless. Our belief is that they will need to take into account basic research on haptic perception in designing these graphics interfaces. We point out constraints and limitations in haptic processing that affect the use of these devices. We also suggest ways to use sound to augment basic information from touch, and we include evaluation data from users of a touch-screen device with vibrotactile and auditory feedback that we have been developing, called a vibro-audio interface.
Microdose analysis of ion strikes on SRAM cells
NASA Astrophysics Data System (ADS)
Scheick, L.
2003-12-01
A method of measuring the effect from exposure to highly localized ionizing radiation on microstructures is described. The voltage at which a commercial SRAM cell cannot hold a programmed state changes with microdose. The microdose distribution across the array, in addition to the analysis of the occurrence of anomalous shifts in operating bias due to rare, large energy-deposition events is studied. The effect of multiple hits on a SRAM cell is presented. A general theory on multiple hits from which basic device parameters can be extracted is presented. SPICE, as well as analysis of basic device physics, is used to analyze the damage to individual transistors and the response of a SRAM cell.
A new submarine oil-water separation system
NASA Astrophysics Data System (ADS)
Cai, Wen-Bin; Liu, Bo-Hong
2017-12-01
In order to solve the oil field losses of environmental problems and economic benefit caused by the separation of lifting production liquid to offshore platforms in the current offshore oil production, from the most basic separation principle, a new oil-water separation system has been processed of adsorption and desorption on related materials, achieving high efficiency and separation of oil and water phases. And the submarine oil-water separation device has been designed. The main structure of the device consists of gas-solid phase separation device, period separating device and adsorption device that completed high efficiency separation of oil, gas and water under the adsorption and desorption principle, and the processing capacity of the device is calculated.
Preface to the special issue of Solid State Electronics EUROSOI/ULIS 2017
NASA Astrophysics Data System (ADS)
Nassiopoulou, Androula G.
2018-05-01
This special issue is devoted to selected papers presented at the EuroSOI-ULIS2017 international conference, held in Athens on 3-5 April 2017. EuroSOI-ULIS2017 Conference was mainly devoted to Si devices, which constitute the basic building blocks of any microelectronic circuit. It included papers on advanced Si technologies, novel nanoscale devices, advanced electronic materials and device architectures, mechanisms involved, test structures, substrate materials and technologies, modeling/simulation and characterization. Both CMOS and beyond CMOS devices were presented, covering the More Moore domain, as well as new functionalities in silicon-compatible nanostructures and innovative devices, representing the More than Moore domain (on-chip sensors, biosensors, energy harvesting devices, RF passives, etc.).
Demonstration Experiments for Solid-State Physics Using a Table-Top Mechanical Stirling Refrigerator
ERIC Educational Resources Information Center
Osorio, M. R.; Morales, A. Palacio; Rodrigo, J. G.; Suderow, H.; Vieira, S.
2012-01-01
Liquid-free cryogenic devices are acquiring importance in basic science and engineering. But they can also lead to improvements in teaching low temperature and solid-state physics to graduate students and specialists. Most of the devices are relatively expensive, but small-sized equipment is slowly becoming available. Here, we have designed…
ERIC Educational Resources Information Center
Hammell, Thomas J.; And Others
A study was conducted to determine the appropriate training objectives for fire control personnel aboard nuclear submarines, to identify specific requirements for training materials to accomplish these objectives, and to provide functional descriptions of recommended training devices. A task analysis was conducted to determine the skill and…
Blending Classroom Teaching and Learning with QR Codes
ERIC Educational Resources Information Center
Rikala, Jenni; Kankaanranta, Marja
2014-01-01
The aim of this case study was to explore the feasibility of the Quick Response (QR) codes and mobile devices in the context of Finnish basic education. The interest was especially to explore how mobile devices and QR codes can enhance and blend teaching and learning. The data were collected with a teacher interview and pupil surveys. The learning…
reflect it. There are commercially available manual and powered suction devices on the market , and several are specifically advertised for use in...combine to suggest that no device on the market meets even the most basic requirements of being small, lightweight, rugged, and demonstrating adequate
Gruber, Elisabeth; Oberhammer, Rosmarie; Balkenhol, Karla; Strapazzon, Giacomo; Procter, Emily; Brugger, Hermann; Falk, Markus; Paal, Peter
2014-04-01
In some emergency situations resuscitation and ventilation may have to be performed by basic life support trained personnel, especially in rural areas where arrival of advanced life support teams can be delayed. The use of advanced airway devices such as endotracheal intubation has been deemphasized for basically-trained personnel, but it is unclear whether supraglottic airway devices are advisable over traditional mask-ventilation. In this prospective, randomized clinical single-centre trial we compared airway management and ventilation performed by nurses using facemask, laryngeal mask Supreme (LMA-S) and laryngeal tube suction-disposable (LTS-D). Basic life support trained nurses (n=20) received one-hour practical training with each device. ASA 1-2 patients scheduled for elective surgery were included (n=150). After induction of anaesthesia and neuromuscular block nurses had two 90-second attempts to manage the airway and ventilate the patient with volume-controlled ventilation. Ventilation failed in 34% of patients with facemask, 2% with LMA-S and 22% with LTS-D (P<0.001). In patients who could be ventilated successfully mean tidal volume was 240±210 ml with facemask, 470±120 ml with LMA-S and 470±140 ml with LTS-D (P<0.001). Leak pressure was lower with LMA-S (23.3±10.8 cm H2O, 95% CI 20.2-26.4) than with LTS-D (28.9±13.9 cm·H2O, 95% CI 24.4-33.4; P=0.047). After one hour of introductory training, nurses were able to use LMA-S more effectively than facemask and LTS-D. High ventilation failure rates with facemask and LTS-D may indicate that additional training is required to perform airway management adequately with these devices. High-level trials are needed to confirm these results in cardiac arrest patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Bombardt, J.
1979-01-01
Papers are presented on the following topics: radiation effects in bipolar microcircuits; basic radiation mechanisms in materials and devices; energy deposition and dosimetry; and system responses from SGEMP, IEMP, and EMP. Also considered are basic processes in SGEMP and IEMP, radiation effects in MOS microcircuits, and space radiation effects and spacecraft charging.
Development of a prototype two-phase thermal bus system for Space Station
NASA Technical Reports Server (NTRS)
Myron, D. L.; Parish, R. C.
1987-01-01
This paper describes the basic elements of a pumped two-phase ammonia thermal control system designed for microgravity environments, the development of the concept into a Space Station flight design, and design details of the prototype to be ground-tested in the Johnson Space Center (JSC) Thermal Test Bed. The basic system concept is one of forced-flow heat transport through interface heat exchangers with anhydrous ammonia being pumped by a device expressly designed for two-phase fluid management in reduced gravity. Control of saturation conditions, and thus system interface temperatures, is accomplished with a single central pressure regulating valve. Flow control and liquid inventory are controlled by passive, nonelectromechanical devices. Use of these simple control elements results in minimal computer controls and high system reliability. Building on the basic system concept, a brief overview of a potential Space Station flight design is given. Primary verification of the system concept will involve testing at JSC of a 25-kW ground test article currently in fabrication.
Precise pooling and dispensing of microfluidic droplets towards micro- to macro-world interfacing
Brouzes, Eric; Carniol, April; Bakowski, Tomasz; Strey, Helmut H.
2014-01-01
Droplet microfluidics possesses unique properties such as the ability to carry out multiple independent reactions without dispersion of samples in microchannels. We seek to extend the use of droplet microfluidics to a new range of applications by enabling its integration into workflows based on traditional technologies, such as microtiter plates. Our strategy consists in developing a novel method to manipulate, pool and deliver a precise number of microfluidic droplets. To this aim, we present a basic module that combines droplet trapping with an on-chip valve. We quantitatively analyzed the trapping efficiency of the basic module in order to optimize its design. We also demonstrate the integration of the basic module into a multiplex device that can deliver 8 droplets at every cycle. This device will have a great impact in low throughput droplet applications that necessitate interfacing with macroscale technologies. The micro- to macro- interface is particularly critical in microfluidic applications that aim at sample preparation and has not been rigorously addressed in this context. PMID:25485102
NASA Technical Reports Server (NTRS)
Cukor, P. M.; Chapman, R. A.
1978-01-01
The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.
Acoustical holographic recording with coherent optical read-out and image processing
NASA Astrophysics Data System (ADS)
Liu, H. K.
1980-10-01
New acoustic holographic wave memory devices have been designed for real-time in-situ recording applications. The basic operating principles of these devices and experimental results through the use of some of the prototypes of the devices are presented. Recording media used in the device include thermoplastic resin, Crisco vegetable oil, and Wilson corn oil. In addition, nonlinear coherent optical image processing techniques including equidensitometry, A-D conversion, and pseudo-color, all based on the new contact screen technique, are discussed with regard to the enhancement of the normally poor-resolved acoustical holographic images.
Advanced technology and truth in advertising
NASA Astrophysics Data System (ADS)
Landauer, Rolf
1990-09-01
Most proposals for new technological approaches fail, and that is reasonable. Despite that, most of the technological proposals arising from basic science are promoted unhesitantly, with little attention to critical appraisal, even little opportunity for the presentation of criticism. We discuss several case histories related to devices intended to displace the transistor in computer logic. Our list includes devices using control of quantum mechanically coherent electron transmission, devices operating at a molecular level, and devices using nonlinear electromagnetic interaction. Neural networks are placed in a different category; something seems to be coming out of this field after several decades of effort.
Color reproduction system based on color appearance model and gamut mapping
NASA Astrophysics Data System (ADS)
Cheng, Fang-Hsuan; Yang, Chih-Yuan
2000-06-01
By the progress of computer, computer peripherals such as color monitor and printer are often used to generate color image. However, cross media color reproduction by human perception is usually different. Basically, the influence factors are device calibration and characterization, viewing condition, device gamut and human psychology. In this thesis, a color reproduction system based on color appearance model and gamut mapping is proposed. It consists of four parts; device characterization, color management technique, color appearance model and gamut mapping.
Feasibility Study for a Dual Field of View-Single Detector Array Infrared System.
1974-06-01
for 525 TV. Per Channelt C. DC. Ainlog& Dgitl Tretrs b~ td ~Secial multipleaed. Organ- 500 li1 cani be organized CAC nlg Dgia eprtr.Untdt 80 lioal...coupled transport phenomenon: charge coupled device (CCD) and bucket brigade device U ( BBD ). These devices are basically dynamic shift registers that...can be connected to form the serial in-serial uut memory. Both the CCD and BBD function by wanipulating char-e along a series of electrodes without
Boyer, K.; Hammel, J.E.; Longmire, C.L.; Nagle, D.E.; Ribe, F.L.; Tuck, J.L.
1961-10-24
ABS>A method and device are described for obtaining fusion reactions. The basic concept is that of using crossed electric and magnetic fields to induce a plasma rotation in which the ionized particles follow a circumferential drift orbit on wldch a cyclotron mode of motion is superimposed, the net result being a cycloidal motion about the axis of symmetry. The discharge tube has a radial electric field and a longitudinal magnetic field. Mirror machine geometry is utilized. The device avoids reliance on the pinch effect and its associated instability problems. (AEC)
Quantum Device Applications of Mesoscopic Superconductivity
NASA Astrophysics Data System (ADS)
Hakonen, P. J.
2006-08-01
A brief account is given on the possibilities of mesoscopic superconductivity in low-noise amplifier and detector applications. In particular, three devices will be described: 1) Bloch oscillating transistor (BOT), 2) Inductively-read superconducting Cooper pair transistor (L-SET), and 3) Quantum capacitive phase detector (C-SET). The BOT is a low-noise current amplifier while the L-SET and C-SET act as ultra-sensitive charge and phase detectors, respectively. The basic operating principles and the main characteristics of these devices will be reviewed and discussed.
FY17 ISCR Scholar End-of-Assignment Report - Robbie Sadre
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sadre, R.
2017-10-20
Throughout this internship assignment, I did various tasks that contributed towards the starting of the SASEDS (Safe Active Scanning for Energy Delivery Systems) and CES-21 (California Energy Systems for the 21st Century) projects in the SKYFALL laboratory. The goal of the SKYFALL laboratory is to perform modeling and simulation verification of transmission power system devices, while integrating with high-performance computing. The first thing I needed to do was acquire official Online LabVIEW training from National Instruments. Through these online tutorial modules, I learned the basics of LabVIEW, gaining experience in connecting to NI devices through the DAQmx API as wellmore » as LabVIEW basic programming techniques (structures, loops, state machines, front panel GUI design etc).« less
Two-Dimensional Photonic Crystals for Sensitive Microscale Chemical and Biochemical Sensing
Miller, Benjamin L.
2015-01-01
Photonic crystals – optical devices able to respond to changes in the refractive index of a small volume of space – are an emerging class of label-free chemical-and bio-sensors. This review focuses on one class of photonic crystal, in which light is confined to a patterned planar material layer of sub-wavelength thickness. These devices are small (on the order of tens to 100s of microns square), suitable for incorporation into lab-on-a-chip systems, and in theory can provide exceptional sensitivity. We introduce the defining characteristics and basic operation of two-dimensional photonic crystal sensors, describe variations of their basic design geometry, and summarize reported detection results from chemical and biological sensing experiments. PMID:25563402
The regulation of cognitive enhancement devices: extending the medical model
Maslen, Hannah; Douglas, Thomas; Cohen Kadosh, Roi; Levy, Neil; Savulescu, Julian
2014-01-01
This article presents a model for regulating cognitive enhancement devices (CEDs). Recently, it has become very easy for individuals to purchase devices which directly modulate brain function. For example, transcranial direct current stimulators are increasingly being produced and marketed online as devices for cognitive enhancement. Despite posing risks in a similar way to medical devices, devices that do not make any therapeutic claims do not have to meet anything more than basic product safety standards. We present the case for extending existing medical device legislation to cover CEDs. Medical devices and CEDs operate by the same or similar mechanisms and pose the same or similar risks. This fact coupled with the arbitrariness of the line between treatment and enhancement count in favour of regulating these devices in the same way. In arguing for this regulatory model, the paper highlights potential challenges to its implementation, and suggests solutions. PMID:25243073
Generalized reciprocity theorem for semiconductor devices
NASA Technical Reports Server (NTRS)
Misiakos, K.; Lindholm, F. A.
1985-01-01
A reciprocity theorem is presented that relates the short-circuit current of a device, induced by a carrier generation source, to the minority-carrier Fermi level in the dark. The basic relation is general under low injection. It holds for three-dimensional devices with position dependent parameters (energy gap, electron affinity, mobility, etc.), and for transient or steady-state conditions. This theorem allows calculation of the internal quantum efficiency of a solar cell by using the analysis of the device in the dark. Other applications could involve measurements of various device parameters, interfacial surface recombination velocity at a polcrystalline silicon emitter contact, for rexample, by using steady-state or transient photon or mass-particle radiation.
A Gas Lubricant Combined Support-sealing Node
NASA Astrophysics Data System (ADS)
Falaleev, S. V.; Nadjari, H.; Vinogradov, A. S.
2018-01-01
The purpose of the research provided in this article is to develop a gas-dynamic device capable of performing the functions of support sealing, unloading devices for axial thrust bearings and damping of axial vibrations of the rotor. Some kinds of seals applied in supports of aircraft engines are known. A face gas-dynamic seal is one of the most effective and standard technology solution for compressors. As the basic element of the developed device, a face gas-dynamic seal with spiral grooves is considered. It also includes the fundamental mathematical calculation of such devices and the experimental research outcomes that form the basis of which such devices can be produced and adapted for use.
Lights, Camera, Spectroscope! The Basics of Spectroscopy Disclosed Using a Computer Screen
ERIC Educational Resources Information Center
Garrido-Gonza´lez, Jose´ J.; Trillo-Alcala´, María; Sa´nchez-Arroyo, Antonio J.
2018-01-01
The generation of secondary colors in digital devices by means of the additive red, green, and blue color model (RGB) can be a valuable way to introduce students to the basics of spectroscopy. This work has been focused on the spectral separation of secondary colors of light emitted by a computer screen into red, green, and blue bands, and how the…
Digital Readers: The Next Chapter in E-Book Reading and Response
ERIC Educational Resources Information Center
Larson, Lotta C.
2010-01-01
The basic features of digital reading devices (such as the Amazon Kindle) are described in this article. The author also considers how such devices can advance e-book readership among primary students by offering new avenues for accessing and interacting with a wide array of texts. Rooted in the transactional theory of reader response and a new…
One-to-One Computing in Public Schools: Lessons from "Laptops for All" Programs
ERIC Educational Resources Information Center
Abell Foundation, 2008
2008-01-01
The basic tenet of one-to-one computing is that the student and teacher have Internet-connected, wireless computing devices in the classroom and optimally at home as well. Also known as "ubiquitous computing," this strategy assumes that every teacher and student has her own computing device and obviates the need for moving classes to…
High power microwave source with a three dimensional printed metamaterial slow-wave structure.
French, David M; Shiffler, Don
2016-05-01
For over the last decade, the concept of metamaterials has led to new approaches for considering the interaction of radiation with complex structures. However, practical manifestations of such a device operating at high power densities have proven difficult to achieve due to the resonant nature of metamaterials and the resultant high electric fields, which place severe constraints on manufacturing the slow wave structures. In this paper, we describe the first experimental manifestation of a high power microwave device utilizing a metallic slow wave structure (metamaterial-like) fabricated using additive manufacturing. The feasibility of utilizing additive manufacturing as a technique for building these relatively complicated structures has thus been demonstrated. The MW class microwave source operates in the C-band and shows frequency tunablility with electron beam voltage. The basic electromagnetic characteristics of this device, the construction using additive manufacturing, and the basic performance as a microwave oscillator are considered. Due to the tunable nature of the device, it shows promise not only as an oscillator but also as a microwave amplifier. Therefore, the dispersive characteristics and a discussion of the anticipated gain is included as it relates to an amplifier configuration.
High power microwave source with a three dimensional printed metamaterial slow-wave structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
French, David M.; Shiffler, Don
2016-05-15
For over the last decade, the concept of metamaterials has led to new approaches for considering the interaction of radiation with complex structures. However, practical manifestations of such a device operating at high power densities have proven difficult to achieve due to the resonant nature of metamaterials and the resultant high electric fields, which place severe constraints on manufacturing the slow wave structures. In this paper, we describe the first experimental manifestation of a high power microwave device utilizing a metallic slow wave structure (metamaterial-like) fabricated using additive manufacturing. The feasibility of utilizing additive manufacturing as a technique for buildingmore » these relatively complicated structures has thus been demonstrated. The MW class microwave source operates in the C-band and shows frequency tunablility with electron beam voltage. The basic electromagnetic characteristics of this device, the construction using additive manufacturing, and the basic performance as a microwave oscillator are considered. Due to the tunable nature of the device, it shows promise not only as an oscillator but also as a microwave amplifier. Therefore, the dispersive characteristics and a discussion of the anticipated gain is included as it relates to an amplifier configuration.« less
Marcus, Hani J; Payne, Christopher J; Hughes-Hallett, Archie; Gras, Gauthier; Leibrandt, Konrad; Nandi, Dipankar; Yang, Guang-Zhong
2016-06-01
To determine the rate and extent of translation of innovative surgical devices from the laboratory to first-in-human studies, and to evaluate the factors influencing such translation. Innovative surgical devices have preceded many of the major advances in surgical practice. However, the process by which devices arising from academia find their way to translation remains poorly understood. All biomedical engineering journals, and the 5 basic science journals with the highest impact factor, were searched between January 1993 and January 2000 using the Boolean search term "surgery OR surgeon OR surgical". Articles were included if they described the development of a new device and a surgical application was described. A recursive search of all citations to the article was performed using the Web of Science (Thompson-Reuters, New York, NY) to identify any associated first-in-human studies published by January 2015. Kaplan-Meier curves were constructed for the time to first-in-human studies. Factors influencing translation were evaluated using log-rank and Cox proportional hazards models. A total of 8297 articles were screened, and 205 publications describing unique devices were identified. The probability of a first-in-human at 10 years was 9.8%. Clinical involvement was a significant predictor of a first-in-human study (P = 0.02); devices developed with early clinical collaboration were over 6 times more likely to be translated than those without [RR 6.5 (95% confidence interval 0.9-48)]. These findings support initiatives to increase clinical translation through improved interactions between basic, translational, and clinical researchers.
Ag2S atomic switch-based `tug of war' for decision making
NASA Astrophysics Data System (ADS)
Lutz, C.; Hasegawa, T.; Chikyow, T.
2016-07-01
For a computing process such as making a decision, a software controlled chip of several transistors is necessary. Inspired by how a single cell amoeba decides its movements, the theoretical `tug of war' computing model was proposed but not yet implemented in an analogue device suitable for integrated circuits. Based on this model, we now developed a new electronic element for decision making processes, which will have no need for prior programming. The devices are based on the growth and shrinkage of Ag filaments in α-Ag2+δS gap-type atomic switches. Here we present the adapted device design and the new materials. We demonstrate the basic `tug of war' operation by IV-measurements and Scanning Electron Microscopy (SEM) observation. These devices could be the base for a CMOS-free new computer architecture.For a computing process such as making a decision, a software controlled chip of several transistors is necessary. Inspired by how a single cell amoeba decides its movements, the theoretical `tug of war' computing model was proposed but not yet implemented in an analogue device suitable for integrated circuits. Based on this model, we now developed a new electronic element for decision making processes, which will have no need for prior programming. The devices are based on the growth and shrinkage of Ag filaments in α-Ag2+δS gap-type atomic switches. Here we present the adapted device design and the new materials. We demonstrate the basic `tug of war' operation by IV-measurements and Scanning Electron Microscopy (SEM) observation. These devices could be the base for a CMOS-free new computer architecture. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00690f
[Industry regulation and its relationship to the rapid marketing of medical devices].
Matsuoka, Atsuko
2012-01-01
In the market of medical devices, non-Japanese products hold a large part even in Japan. To overcome this situation, the Japanese government has been announcing policies to encourage the medical devices industry, such as the 5-year strategy for medical innovation (June 6, 2012). The Division of Medical Devices has been contributing to rapid marketing of medical devices by working out the standards for approval review and accreditation of medical devices, guidances on evaluation of medical devices with emerging technology, and test methods for biological safety evaluation of medical devices, as a part of practice in the field of regulatory science. The recent outcomes are 822 standards of accreditation for Class II medical devices, 14 guidances on safety evaluation of medical devices with emerging technology, and the revised test methods for biological safety evaluation (MHLW Notification by Director, OMDE, Yakushokuki-hatsu 0301 No. 20 "Basic Principles of Biological Safety Evaluation Required for Application for Approval to Market Medical Devices").
Technology assessment of medical devices at the Center for Devices and Radiological Health.
Kessler, L; Richter, K
1998-09-25
We reviewed the Food and Drug Administration's regulatory process for medical devices and described the issues that arise in assessing device safety and effectiveness during the postmarket period. The Center for Devices and Radiological Health (CDRH), an organization within the Food and Drug Administration, has the legal authority and responsibility for ensuring that medical devices marketed in the United States are both reasonably safe and effective for their intended use. This is an enormous challenge given the diversity of medical devices and the large number of different types of devices on the market. Many scientific and regulatory activities are necessary to ensure device safety and effectiveness, including technology assessment, albeit in a manner quite different from that of conventional technology assessment. The basic approach taken at the CDRH to ensure device safety and effectiveness is to develop an understanding of the way in which a medical device works and how it will perform in clinical situations.
Regeneration of the lung: Lung stem cells and the development of lung mimicking devices.
Schilders, Kim A A; Eenjes, Evelien; van Riet, Sander; Poot, André A; Stamatialis, Dimitrios; Truckenmüller, Roman; Hiemstra, Pieter S; Rottier, Robbert J
2016-04-23
Inspired by the increasing burden of lung associated diseases in society and an growing demand to accommodate patients, great efforts by the scientific community produce an increasing stream of data that are focused on delineating the basic principles of lung development and growth, as well as understanding the biomechanical properties to build artificial lung devices. In addition, the continuing efforts to better define the disease origin, progression and pathology by basic scientists and clinicians contributes to insights in the basic principles of lung biology. However, the use of different model systems, experimental approaches and readout systems may generate somewhat conflicting or contradictory results. In an effort to summarize the latest developments in the lung epithelial stem cell biology, we provide an overview of the current status of the field. We first describe the different stem cells, or progenitor cells, residing in the homeostatic lung. Next, we focus on the plasticity of the different cell types upon several injury-induced activation or repair models, and highlight the regenerative capacity of lung cells. Lastly, we summarize the generation of lung mimics, such as air-liquid interface cultures, organoids and lung on a chip, that are required to test emerging hypotheses. Moreover, the increasing collaboration between distinct specializations will contribute to the eventual development of an artificial lung device capable of assisting reduced lung function and capacity in human patients.
... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco ... 164KB) En Español Basic Facts 7 Tips for Testing Your Blood Sugar and Caring for Your Meter ...
Electronic device aspects of neural network memories
NASA Technical Reports Server (NTRS)
Lambe, J.; Moopenn, A.; Thakoor, A. P.
1985-01-01
The basic issues related to the electronic implementation of the neural network model (NNM) for content addressable memories are examined. A brief introduction to the principles of the NNM is followed by an analysis of the information storage of the neural network in the form of a binary connection matrix and the recall capability of such matrix memories based on a hardware simulation study. In addition, materials and device architecture issues involved in the future realization of such networks in VLSI-compatible ultrahigh-density memories are considered. A possible space application of such devices would be in the area of large-scale information storage without mechanical devices.
Fast-acting self-healing metallic fuse.
NASA Technical Reports Server (NTRS)
Schwartz, F. C.; Renton, C. A.; Rabinovici, B.
1971-01-01
Description of a fast-acting nonmechanical self-healing mercury fuse capable of protecting a high current circuit or device from overcurrent fault damages. Basically the self-healing fuse consists of two enclosed mercury reservoirs connected by a fine capillary tube filled with mercury that serves as the fusing element. It is pointed out that a better understanding of the energy conversion process involved in the operation of the device could help explore other device configurations (such as a tapering geometry and use of magnetic field to drive the arc into the fuse wall on inductive loads, etc.) and thus extend the range of capabilities for this type of protective device.
Total Dose Effects in Conventional Bipolar Transistors
NASA Technical Reports Server (NTRS)
Johnston, A. H.; Swift, G. W.; Rax, B. G.
1994-01-01
This paper examines various factors in bipolar device construction and design, and discusses their impact on radiation hardness. The intent of the paper is to improve understanding of the underlying mechanisms for practical devices without special test structures, and to provide (1) guidance in ways to select transistor designs that are more resistant to radiation damage, and (2) methods to estimate the maximum amount of damage that might be expected from a basic transistor design. The latter factor is extremely important in assessing the risk that future lots of devices will be substantially below design limits, which are usually based on test data for older devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarillo-Herrero, Pablo
This is the final report of our research program on electronic transport experiments on Topological Insulator (TI) devices, funded by the DOE Office of Basic Energy Sciences. TI-based electronic devices are attractive as platforms for spintronic applications, and for detection of emergent properties such as Majorana excitations , electron-hole condensates , and the topological magneto-electric effect . Most theoretical proposals envision geometries consisting of a planar TI device integrated with materials of distinctly different physical phases (such as ferromagnets and superconductors). Experimental realization of physics tied to the surface states is a challenge due to the ubiquitous presence of bulkmore » carriers in most TI compounds as well as degradation during device fabrication.« less
Microbial Check Valve for Shuttle
NASA Technical Reports Server (NTRS)
Colombo, G. V.; Putnam, D. F.; Sauer, R. L.
1978-01-01
The Microbial Check Valve (MCV) is a device developed for the Space Shuttle that prevents the transfer of viable microorganisms within water systems. The device is essentially a bed of resin material, impregnated with iodine, that kills microorganisms on contact. It prevents the cross-contamination of microorganisms from a nonpotable system into the potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the 'air gap' found in conventional one-gravity systems. Basic design data are presented including pressure drop, scaling factors, sizing criteria, and the results of challenging the device with suspensions of seven microorganisms including aerobes, anaerobes and spore formers.
Net current control device. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fugate, D.; Cooper, J.H.
1998-11-01
Net currents generally result in elevated magnetic fields because the alternate paths are distant from the circuit conductors. Investigations have shown that one of the primary sources of power frequency magnetic fields in residential buildings is currents that return to their source via paths other than the neutral conductors. As part of EPRI`s Magnetic Field Shielding Project, ferromagnetic devices, called net current control (NCC) devices, were developed and tested for use in reducing net currents on electric power cables and the resulting magnetic fields. Applied to a residential service drop, an NCC device reduces net current by forcing current offmore » local non-utility ground paths, and back onto the neutral conductor. Circuit models and basic design equations for the NCC concept were developed, and proof-of-principles tests were carried out on an actual residence with cooperation from the local utility. After proving the basic concepts, three prototype NCC devices were built and tested on a simulated neighborhood power system. Additional prototypes were built for testing by interested EPRI utility members. Results have shown that the NCC prototypes installed on residential service drops reduce net currents to milliampere levels with compromising the safety of the ground system. Although the focus was on application to residential service cables, the NCC concept is applicable to single-phase and three-phase distribution systems as well.« less
Reliability Prediction Modeling of New Devices.
1980-07-01
film of magnetic material on a nonmagnetic garnet crystal substrate with a surround- ing magnetic bias field mechanism to complete the basic hybrid...semiconductor processes. The magnetic domain centers are formed in a magnetic epitaxial film of garnet crystal on a nonmagnetic garnet substrate, and...polarity. The most widely used basic substrate is a high-purity gadolinium garnet . The thin- film magnetic layer is of the same crystal class with a
ERIC Educational Resources Information Center
Hatun Atas, Amine; Delialioglu, Ömer
2018-01-01
The aim of this study was to explore the opinions, perceptions and evaluations of students about their experiences with a question-answer system used on mobile devices in a lecture-based course. Basic qualitative research method was employed in this study to understand how students made sense of their experiences during the instruction. The…
Heterojunction Solid-State Devices for Millimeter-Wave Sources.
1983-10-01
technology such as MBE and/or OK-CVD will be required. Our large-signal, numerical WATT device simulations are the first to predict from basic transport...results are due to an improved method for determining semiconductor material parameters. We use a theoretical Monte Carlo materials simulation ... simulations . These calculations have helped provide insight into velocity overshoot and ballistic transport phenomena. We find that ballistic or near
Manufacturing Methods and Technology Project Summary Reports
1981-06-01
a tough urethane film. The basic principle is to pump two components to a spinning disc, mixing the components just prior to depositing in a well...and check out an electronic target scoring device using developed scientific principles without drastically modifying existing commercial...equipment. The scoring device selected and installed was an Accubar Model ATS-16D using the underlying physics principle of acoustic shock wave propagation
Piezoelectric Energy Harvesting Solutions
Caliò, Renato; Rongala, Udaya Bhaskar; Camboni, Domenico; Milazzo, Mario; Stefanini, Cesare; de Petris, Gianluca; Oddo, Calogero Maria
2014-01-01
This paper reviews the state of the art in piezoelectric energy harvesting. It presents the basics of piezoelectricity and discusses materials choice. The work places emphasis on material operating modes and device configurations, from resonant to non-resonant devices and also to rotational solutions. The reviewed literature is compared based on power density and bandwidth. Lastly, the question of power conversion is addressed by reviewing various circuit solutions. PMID:24618725
Elastic Domain Wall Waves in Ferroelectric Ceramics and Single Crystals
1988-07-01
properties of piezoelectric and electrostrictive types of ferroelectric ceramics and single crystals. This was for the purpose of shedding light on the...effectiveness and general characteristics of fabrication techniques, as well as exploring basic physical mechanisms playing a role in the technology of...routing and processing devices on small ferroelectric wafers, fabricated by simple inexpensive poling and biasing techniques. Such devices ma) be
Timing the Random and Anomalous Arrival of Particles in a Geiger Counter with GPS Devices
ERIC Educational Resources Information Center
Blanco, F.; La Rocca, P.; Riggi, F.; Riggi, S.
2008-01-01
The properties of the arrival time distribution of particles in a detector have been studied by the use of a small Geiger counter, with a GPS device to tag the event time. The experiment is intended to check the basic properties of the random arrival time distribution between successive events and to simulate the investigations carried out by…
Color Reproduction System Based on Color Appearance Model and Gamut Mapping
2000-07-01
and Gamut Mapping DISTRIBUTION: Approved for public release, distribution unlimited This paper is part of the following report: TITLE: Input/Output...report: ADP011333 thru ADP011362 UNCLASSIFIED Color reproduction system based on color appearance model and gamut mapping Fang-Hsuan Cheng, Chih-Yuan...perception is usually different. Basically, the influence factors are device calibration and characterization, viewing condition, device gamut and human
Experimental Research of a New Wave Energy Conversion Device
NASA Astrophysics Data System (ADS)
Lu, Zhongyue; Shang, Jianzhong; Luo, Zirong; Sun, Chongfei; Chen, Gewei
2018-01-01
With the increasing tension of contemporary social energy, the development and utilization of renewable energy has become an important development direction. As an important part of renewable energy, wave energy has the characteristics of green environmental protection and abundant reserves, attracting more investment and research. For small marine equipment energy supply problem, this paper puts forward a micro wave energy conversion device as the basic of heaving motion of waves in the ocean. This paper designed a new type of power output device can solve the micro wave energy conversion problem.
Method and device for stand-off laser drilling and cutting
Copley, John A.; Kwok, Hoi S.; Domankevitz, Yacov
1989-09-26
A device for perforating material and a method of stand-off drilling using a laser. In its basic form a free-running laser beam creates a melt on the target and then a Q-switched short duration pulse is used to remove the material through the creation of a laser detonation wave. The advantage is a drilling/cutting method capable of working a target at lengthy stand-off distance. The device may employ 2 lasers or a single one operated in a free-running/Q-switched dual mode.
Diagnostic devices for isothermal nucleic acid amplification.
Chang, Chia-Chen; Chen, Chien-Cheng; Wei, Shih-Chung; Lu, Hui-Hsin; Liang, Yang-Hung; Lin, Chii-Wann
2012-01-01
Since the development of the polymerase chain reaction (PCR) technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development.
A Study of Al-Mn Transition Edge Sensor Engineering for Stability
DOE Office of Scientific and Technical Information (OSTI.GOV)
George, E. M.; et al.
2013-11-10
The stability of Al-Mn transition edge sensor (TES) bolometers is studied as we vary the engineered TES transition, heat capacity, and/or coupling between the heat capacity and TES. We present thermal structure measurements of each of the 39 designs tested. The data is accurately fit by a two-body bolometer model, which allows us to extract the basic TES parameters that affect device stability. We conclude that parameters affecting device stability can be engineered for optimal device operation, and present the model parameters extracted for the different TES designs.
Diagnostic Devices for Isothermal Nucleic Acid Amplification
Chang, Chia-Chen; Chen, Chien-Cheng; Wei, Shih-Chung; Lu, Hui-Hsin; Liang, Yang-Hung; Lin, Chii-Wann
2012-01-01
Since the development of the polymerase chain reaction (PCR) technique, genomic information has been retrievable from lesser amounts of DNA than previously possible. PCR-based amplifications require high-precision instruments to perform temperature cycling reactions; further, they are cumbersome for routine clinical use. However, the use of isothermal approaches can eliminate many complications associated with thermocycling. The application of diagnostic devices for isothermal DNA amplification has recently been studied extensively. In this paper, we describe the basic concepts of several isothermal amplification approaches and review recent progress in diagnostic device development. PMID:22969402
Acoustic charge transport technology investigation for advanced development transponder
NASA Technical Reports Server (NTRS)
Kayalar, S.
1993-01-01
Acoustic charge transport (ACT) technology has provided a basis for a new family of analog signal processors, including a programmable transversal filter (PTF). Through monolithic integration of ACT delay lines with GaAs metal semiconductor field effect transistor (MESFET) digital memory and controllers, these devices significantly extend the performance of PTF's. This article introduces the basic operation of these devices and summarizes their present and future specifications. The production and testing of these devices indicate that this new technology is a promising one for future space applications.
Water-assisted femtosecond laser machining of electrospray nozzles on glass microfluidic devices.
An, Ran; Hoffman, Michelle D; Donoghue, Margaret A; Hunt, Alan J; Jacobson, Stephen C
2008-09-15
Using water-assisted femtosecond laser machining, we fabricated electrospray nozzles on glass coverslips and on assembled microfluidic devices. Machining the nozzles after device assembly facilitated alignment of the nozzles over the microchannels. The basic nozzle design is a through-hole in the coverslip to pass liquids and a trough machined around the through-hole to confine the electrospray and prevent liquid from wicking across the glass surface. Electrospray from the nozzles was stable with and without pressure-driven flow applied and was evaluated using mass spectra of the peptide bradykinin.
Basic-CPR and AIDS: are volunteer life-savers prepared for a storm?
Bierens, J J; Berden, H J
1996-10-01
Professional health care workers have access to guidelines, equipment and techniques to reduce the exposure to infectious material in case of resuscitation. The current official content of national courses for volunteer life-savers do not address this issue, as far as we know. Concern about the risks of infection due to resuscitation is increasing in this group. This article describes a rational approach of the problem, that includes data on the infection risk of basic-CPR, and an approach that accepts that the concern can not be controlled by objective data. In such an emotional approach, direct contact has to be minimised by using devices. Requirements for resuscitation devices with a barrier function are listed. Although both approaches will reduce the fear of infection, we advice a rational approach.
Development of Quasi-3DOF upper limb rehabilitation system using ER brake: PLEMO-P1
NASA Astrophysics Data System (ADS)
Kikuchi, T.; Fukushima, K.; Furusho, J.; Ozawa, T.
2009-02-01
In recent years, many researchers have studied the potential of using robotics technology to assist and quantify the motor functions for neuron-rehabilitation. Some kinds of haptic devices have been developed and evaluated its efficiency with clinical tests, for example, upper limb training for patients with spasticity after stroke. However, almost all the devices are active-type (motor-driven) haptic devices and they basically require high-cost safety system compared to passive-type (brake-based) devices. In this study, we developed a new practical haptic device 'PLEMO-P1'; this system adopted ER brakes as its force generators. In this paper, the mechanism of PLEMO-P1 and its software for a reaching rehabilitation are described.
Human-computer dialogue: Interaction tasks and techniques. Survey and categorization
NASA Technical Reports Server (NTRS)
Foley, J. D.
1983-01-01
Interaction techniques are described. Six basic interaction tasks, requirements for each task, requirements related to interaction techniques, and a technique's hardware prerequisites affective device selection are discussed.
On-sky verification of the 6-h periodic basic angle variations of the Gaia satellite
NASA Astrophysics Data System (ADS)
Liao, Shilong; Lattanzi, Mario G.; Vecchiato, Alberto; Qi, Zhaoxiang; Crosta, Mariateresa; Tang, Zhenghong
2018-04-01
A Basic Angle (BA) of 106.5° separates the view directions of Gaia's two fields of view (FoV). A precise determination of the BA variations (BAV) is essential to guarantee a correct reconstruction of the global astrometric sphere, as residual systematic errors would result in, e.g., a bias in the parallaxes of the final Gaia catalog. The Basic Angle Monitoring (BAM) device, which provides a reliable and accurate estimation of BAV, shows that there exists a ~1 mas amplitude, 6-h period BA oscillation. It's essential to verify to what extent this signal is caused by real BAV, or is at least in part an effect of the BAM device itself. Here, we propose an astrometric on-sky approach to re-determine the 6-h periodic BAV. The results of this experiment, which treated a full day (17 Oct 2016) of Gaia astrometric data, recover a value for the 6-h oscillation of 1.856+/-0.857 mas. This is consistent, within the errors, with the BAM finding for that day.
Mattingly, Emily
2005-04-01
The technological complexity of implantable arrhythmia management devices, specifically pacemakers and defibrillators, has increased dramatically since their introduction only a few decades ago. Patients with such devices are encountered much more frequently in hospitals and surgery centers, yet anesthesia provider knowledge of safe and proper management is often incomplete. Anesthesia textbooks and references may provide only short paragraphs on arrhythmia management devices that do not address important perioperative management strategies for this ever-growing patient population. It is no longer satisfactory to simply place a magnet over an implanted device during surgery and assume that this action protects the patient from harm due to electromagnetic interference from inappropriate device function. This AANA Journal course serves as a concise review of basic device function, the sources and effects of electromagnetic interference in the operative setting, and patient management recommendations from current literature.
Determining Desirable Cursor Control Device Characteristics for NASA Exploration Missions
NASA Technical Reports Server (NTRS)
Sandor, Aniko; Holden, Kritina L.
2007-01-01
A test battery was developed for cursor control device evaluation: four tasks were taken from ISO 9241-9, and three from previous studies conducted at NASA. The tasks focused on basic movements such as pointing, clicking, and dragging. Four cursor control devices were evaluated with and without Extravehicular Activity (EVA) gloves to identify desirable cursor control device characteristics for NASA missions: 1) the Kensington Expert Mouse, 2) the Hulapoint mouse, 3) the Logitech Marble Mouse, and 4) the Honeywell trackball. Results showed that: 1) the test battery is an efficient tool for differentiating among input devices, 2) gloved operations were about 1 second slower and had at least 15% more errors; 3) devices used with gloves have to be larger, and should allow good hand positioning to counteract the lack of tactile feedback, 4) none of the devices, as designed, were ideal for operation with EVA gloves.
Johnson, Jani A; Xu, Jingjing; Cox, Robyn M
2016-01-01
Modern hearing aid (HA) devices include a collection of acoustic signal-processing features designed to improve listening outcomes in a variety of daily auditory environments. Manufacturers market these features at successive levels of technological sophistication. The features included in costlier premium hearing devices are designed to result in further improvements to daily listening outcomes compared with the features included in basic hearing devices. However, independent research has not substantiated such improvements. This research was designed to explore differences in speech-understanding and listening-effort outcomes for older adults using premium-feature and basic-feature HAs in their daily lives. For this participant-blinded, repeated, crossover trial 45 older adults (mean age 70.3 years) with mild-to-moderate sensorineural hearing loss wore each of four pairs of bilaterally fitted HAs for 1 month. HAs were premium- and basic-feature devices from two major brands. After each 1-month trial, participants' speech-understanding and listening-effort outcomes were evaluated in the laboratory and in daily life. Three types of speech-understanding and listening-effort data were collected: measures of laboratory performance, responses to standardized self-report questionnaires, and participant diary entries about daily communication. The only statistically significant superiority for the premium-feature HAs occurred for listening effort in the loud laboratory condition and was demonstrated for only one of the tested brands. The predominant complaint of older adults with mild-to-moderate hearing impairment is difficulty understanding speech in various settings. The combined results of all the outcome measures used in this research suggest that, when fitted using scientifically based practices, both premium- and basic-feature HAs are capable of providing considerable, but essentially equivalent, improvements to speech understanding and listening effort in daily life for this population. For HA providers to make evidence-based recommendations to their clientele with hearing impairment it is essential that further independent research investigates the relative benefit/deficit of different levels of hearing technology across brands and manufacturers in these and other real-world listening domains.
ERIC Educational Resources Information Center
Chief of Naval Education and Training Support, Pensacola, FL.
This student guidebook is designed for use with the study booklets in modules 32 through 34 included in the military-developed course on basic electricity and electronics. The course is one of a number of military-developed curriculum packages selected for adaptation to vocational instructional and curriculum development in a civilian setting. An…
A Service-oriented Approach towards Context-aware Mobile Learning Management Systems
2010-07-01
towards a pervasive university. Keywords-context-aware computing, service-oriented archi- tecture, mobile computing, elearning , learn management sys- tem I...usage of device- specific features provide support for various ubiquitous and pervasive eLearning scenarios [2][3]. By knowing where the user currently...data from the mobile device towards a context-aware mobile LMS. II. BASIC CONCEPTS For a better understanding of the presented eLearning sce- narios
Soviet Development of Gyrotrons
1986-05-01
Relationship Type of Device Remarks V, - Vc, anomalous Doppler Capable of 100 percent efficiency, CRM but more cumbersome than Cheren- kov devices V...authors; and discusses inlividual Soviet reseaLc- groups, the basic organizational units responAiLle for the CRM and gyrotron research and development. The...maintained a cCnEistEnt iecord of significant achievements; it has managed to overcome the systenic yeaxness of the Soviet R&C systeg in teimg atle to
Investigation of Basic Mechanisms of Radiation Effects in Carbon-Based Electronic Materials
2017-06-01
materials characterization, and carbon nanotube diodes, FET, and PZT-memory test device structures for electrical measurements. Pre - and post -irradiation...definition (Radiation exposure) Task 2) The grantee shall perform testing to include: - Radiation testing . May be multiple types. - Pre and post -rad...technologies for electronic devices. Experiential radiation testing has included exposure to 10 keV X-rays, 4 MeV protons, heavy ions, and Ultra
Design of wireless communication system for environmental monitoring
NASA Astrophysics Data System (ADS)
Jiang, Li; Zhang, Xiaoyang; Sun, Zhixiang; Tian, Youcheng; Wang, Juan; Guo, Jianghua
2017-05-01
This paper introduces the basic principle and advantages of GPRS data transmission, and discusses in detail about the hardware structure of the GPRS module, the connection mode and the research process of GPRS application in the device. The feasibility and superiority of GPRS data transmission in wireless water quality monitoring device have been tested and proved, which provides great convenience for water quality monitoring, and has good application prospect.
Flow Structures and Interactions of a Fail-Safe Actuator
NASA Astrophysics Data System (ADS)
Khan, Wasif; Elimelech, Yoseph; Amitay, Michael
2010-11-01
Vortex generators are passive devices that are commonly used in many aerodynamic applications. In their basic concept, they enhance mixing, reduce or mitigate flow separation; however, they cause drag penalties at off design conditions. Micro vanes implement the same basic idea of vortex generators but their physical dimensions are much smaller. To achieve the same effect on the baseline flow field, micro vanes are combined with an active flow control device, so their net effect is comparable to that of vortex generators when the active device is energized. As a result of their small size, micro vanes have significantly less drag penalty at off design conditions. This concept of "dual-action" is the reason why such actuation is commonly called hybrid or fail-safe actuation. The present study explores experimentally the flow interaction of a synthetic-jet with a micro vane in a zero pressure gradient flow over a flat plate. Using the stereo particle image velocimetry technique a parametric study was conducted, where the effects of the micro vane shape, height and its angle with respect to the flow were examined, at several blowing ratios and synthetic-jet configurations.
NASA Technical Reports Server (NTRS)
Lee, F. C.; Chen, D. Y.; Jovanovic, M.; Hopkins, D. C.
1985-01-01
The results of evaluation of power semiconductor devices for electric hybrid vehicle ac drive applications are summarized. Three types of power devices are evaluated in the effort: high power bipolar or Darlington transistors, power MOSFETs, and asymmetric silicon control rectifiers (ASCR). The Bipolar transistors, including discrete device and Darlington devices, range from 100 A to 400 A and from 400 V to 900 V. These devices are currently used as key switching elements inverters for ac motor drive applications. Power MOSFETs, on the other hand, are much smaller in current rating. For the 400 V device, the current rating is limited to 25 A. For the main drive of an electric vehicle, device paralleling is normally needed to achieve practical power level. For other electric vehicle (EV) related applications such as battery charger circuit, however, MOSFET is advantageous to other devices because of drive circuit simplicity and high frequency capability. Asymmetrical SCR is basically a SCR device and needs commutation circuit for turn off. However, the device poses several advantages, i.e., low conduction drop and low cost.
Water system microbial check valve development
NASA Technical Reports Server (NTRS)
Colombo, G. V.; Greenley, D. R.; Putnam, D. F.
1978-01-01
Development work on a device for the Space Shuttle that will prevent the transfer of viable microorganisms within water systems is described. The device serves as a check valve in that it prevents the transfer or cross-contamination of microorganisms from a nonpotable system into a potable water system when these systems are interconnected. In this regard, the function of the device is similar to that of the air gap found in conventional one gravity systems. The device is essentially a bed of resin material impregnated with iodine. Basic design data for a variety of flow and temperature conditions are presented, together with results of challenging the beds with suspensions of seven microorganisms including aerobes, anaerobes, and spore formers.
Wide Bandgap Extrinsic Photoconductive Switches
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, James S.
2012-01-20
Photoconductive semiconductor switches (PCSS) have been investigated since the late 1970s. Some devices have been developed that withstand tens of kilovolts and others that switch hundreds of amperes. However, no single device has been developed that can reliably withstand both high voltage and switch high current. Yet, photoconductive switches still hold the promise of reliable high voltage and high current operation with subnanosecond risetimes. Particularly since good quality, bulk, single crystal, wide bandgap semiconductor materials have recently become available. In this chapter we will review the basic operation of PCSS devices, status of PCSS devices and properties of the widemore » bandgap semiconductors 4H-SiC, 6H-SiC and 2H-GaN.« less
The HelCat Helicon-Cathode Device at UNM
NASA Astrophysics Data System (ADS)
Cyrin, Bricette; Watts, Christopher; Gilmore, Mark; Hayes, Tiffany; Kelly, Ralph; Leach, Christopher; Lynn, Alan; Sanchez, Andrew; Xie, Shuangwei; Yan, Lincan; Zhang, Yue
2009-11-01
The HelCat helicon-cathode device is a dual-source linear plasma device for investigating a wide variety of basic plasma phenomena. HelCat is 4 m long, 50 cm diameter, with axial magnetic field < 2.2 kG. An RF helicon source is at one end of the device, and a thermionic BaO-Ni cathode is at the other end. Current research topics include the relationship of turbulence to sheared plasma flows, deterministic chaos, Alfv'en wave propagation and damping, and merging plasma interaction. We present an overview of the ongoing research, and focus on recent results of merging helicon and cathode plasma. We will present some really cool movies.
Modeling malware propagation using a carrier compartment
NASA Astrophysics Data System (ADS)
Hernández Guillén, J. D.; Martín del Rey, A.
2018-03-01
The great majority of mathematical models proposed to simulate malware spreading are based on systems of ordinary differential equations. These are compartmental models where the devices are classified according to some types: susceptible, exposed, infectious, recovered, etc. As far as we know, there is not any model considering the special class of carrier devices. This type is constituted by the devices whose operative systems is not targeted by the malware (for example, iOS devices for Android malware). In this work a novel mathematical model considering this new compartment is considered. Its qualitative study is presented and a detailed analysis of the efficient control measures is shown by studying the basic reproductive number.
Code of Federal Regulations, 2014 CFR
2014-10-01
... devices, and other basic medical and rescue equipment and their primary function will be rescue activities. ... eligible to be included in any award under this program. New mission is a first-responder function that a...
Code of Federal Regulations, 2013 CFR
2013-10-01
... devices, and other basic medical and rescue equipment and their primary function will be rescue activities. ... eligible to be included in any award under this program. New mission is a first-responder function that a...
Rotary wave-ejector enhanced pulse detonation engine
NASA Astrophysics Data System (ADS)
Nalim, M. R.; Izzy, Z. A.; Akbari, P.
2012-01-01
The use of a non-steady ejector based on wave rotor technology is modeled for pulse detonation engine performance improvement and for compatibility with turbomachinery components in hybrid propulsion systems. The rotary wave ejector device integrates a pulse detonation process with an efficient momentum transfer process in specially shaped channels of a single wave-rotor component. In this paper, a quasi-one-dimensional numerical model is developed to help design the basic geometry and operating parameters of the device. The unsteady combustion and flow processes are simulated and compared with a baseline PDE without ejector enhancement. A preliminary performance assessment is presented for the wave ejector configuration, considering the effect of key geometric parameters, which are selected for high specific impulse. It is shown that the rotary wave ejector concept has significant potential for thrust augmentation relative to a basic pulse detonation engine.
Alexa, Siri, Cortana, and More: An Introduction to Voice Assistants.
Hoy, Matthew B
2018-01-01
Voice assistants are software agents that can interpret human speech and respond via synthesized voices. Apple's Siri, Amazon's Alexa, Microsoft's Cortana, and Google's Assistant are the most popular voice assistants and are embedded in smartphones or dedicated home speakers. Users can ask their assistants questions, control home automation devices and media playback via voice, and manage other basic tasks such as email, to-do lists, and calendars with verbal commands. This column will explore the basic workings and common features of today's voice assistants. It will also discuss some of the privacy and security issues inherent to voice assistants and some potential future uses for these devices. As voice assistants become more widely used, librarians will want to be familiar with their operation and perhaps consider them as a means to deliver library services and materials.
Efficiency of bulk-heterojunction organic solar cells
Scharber, M.C.; Sariciftci, N.S.
2013-01-01
During the last years the performance of bulk heterojunction solar cells has been improved significantly. For a large-scale application of this technology further improvements are required. This article reviews the basic working principles and the state of the art device design of bulk heterojunction solar cells. The importance of high power conversion efficiencies for the commercial exploitation is outlined and different efficiency models for bulk heterojunction solar cells are discussed. Assuming state of the art materials and device architectures several models predict power conversion efficiencies in the range of 10–15%. A more general approach assuming device operation close to the Shockley–Queisser-limit leads to even higher efficiencies. Bulk heterojunction devices exhibiting only radiative recombination of charge carriers could be as efficient as ideal inorganic photovoltaic devices. PMID:24302787
NASA Astrophysics Data System (ADS)
Liberal, Iñigo; Engheta, Nader
2018-02-01
Quantum emitters interacting through a waveguide setup have been proposed as a promising platform for basic research on light-matter interactions and quantum information processing. We propose to augment waveguide setups with the use of multiport devices. Specifically, we demonstrate theoretically the possibility of exciting N -qubit subradiant, maximally entangled, states with the use of suitably designed N -port devices. Our general methodology is then applied based on two different devices: an epsilon-and-mu-near-zero waveguide hub and a nonreciprocal circulator. A sensitivity analysis is carried out to assess the robustness of the system against a number of nonidealities. These findings link and merge the designs of devices for quantum state engineering with classical communication network methodologies.
Computer-aided engineering of semiconductor integrated circuits
NASA Astrophysics Data System (ADS)
Meindl, J. D.; Dutton, R. W.; Gibbons, J. F.; Helms, C. R.; Plummer, J. D.; Tiller, W. A.; Ho, C. P.; Saraswat, K. C.; Deal, B. E.; Kamins, T. I.
1980-07-01
Economical procurement of small quantities of high performance custom integrated circuits for military systems is impeded by inadequate process, device and circuit models that handicap low cost computer aided design. The principal objective of this program is to formulate physical models of fabrication processes, devices and circuits to allow total computer-aided design of custom large-scale integrated circuits. The basic areas under investigation are (1) thermal oxidation, (2) ion implantation and diffusion, (3) chemical vapor deposition of silicon and refractory metal silicides, (4) device simulation and analytic measurements. This report discusses the fourth year of the program.
Stereo optical guidance system for control of industrial robots
NASA Technical Reports Server (NTRS)
Powell, Bradley W. (Inventor); Rodgers, Mike H. (Inventor)
1992-01-01
A device for the generation of basic electrical signals which are supplied to a computerized processing complex for the operation of industrial robots. The system includes a stereo mirror arrangement for the projection of views from opposite sides of a visible indicia formed on a workpiece. The views are projected onto independent halves of the retina of a single camera. The camera retina is of the CCD (charge-coupled-device) type and is therefore capable of providing signals in response to the image projected thereupon. These signals are then processed for control of industrial robots or similar devices.
Blinov, N N
2000-01-01
Specifications for the main element of a modern X-ray diagnostic device an X-ray feeder are formulated. There is evidence for choosing its parameters. The new rational routine of X-ray study and the layout of a X-ray room are proposed. Information on the up-to-date commercially manufactured basic medium-frequency general-purpose X-ray feeder "URP-30 SCh Amico" is given.
Milanovic, Jovana Z; Milanovic, Predrag; Kragic, Rastislav; Kostic, Mirjana
2018-01-01
In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source "OpenPhControl" software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device's utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary.
Stoot, Lauren J.; Cairns, Nicholas A.; Cull, Felicia; Taylor, Jessica J.; Jeffrey, Jennifer D.; Morin, Félix; Mandelman, John W.; Clark, Timothy D.; Cooke, Steven J.
2014-01-01
Non-human vertebrate blood is commonly collected and assayed for a variety of applications, including veterinary diagnostics and physiological research. Small, often non-lethal samples enable the assessment and monitoring of the physiological state and health of the individual. Traditionally, studies that rely on blood physiology have focused on captive animals or, in studies conducted in remote settings, have required the preservation and transport of samples for later analysis. In either situation, large, laboratory-bound equipment and traditional assays and analytical protocols are required. The use of point-of-care (POC) devices to measure various secondary blood physiological parameters, such as metabolites, blood gases and ions, has become increasingly popular recently, due to immediate results and their portability, which allows the freedom to study organisms in the wild. Here, we review the current uses of POC devices and their applicability to basic and applied studies on a variety of non-domesticated species. We located 79 individual studies that focused on non-domesticated vertebrates, including validation and application of POC tools. Studies focused on a wide spectrum of taxa, including mammals, birds and herptiles, although the majority of studies focused on fish, and typical variables measured included blood glucose, lactate and pH. We found that calibrations for species-specific blood physiology values are necessary, because ranges can vary within and among taxa and are sometimes outside the measurable range of the devices. In addition, although POC devices are portable and robust, most require durable cases, they are seldom waterproof/water-resistant, and factors such as humidity and temperature can affect the performance of the device. Overall, most studies concluded that POC devices are suitable alternatives to traditional laboratory devices and eliminate the need for transport of samples; however, there is a need for greater emphasis on rigorous calibration and validation of these units and appreciation of their limitations. PMID:27293632
Electro-optical characterization of GaAs solar cells
NASA Technical Reports Server (NTRS)
Olsen, Larry C.; Dunham, Glen; Addis, F. W.; Huber, Dan; Daling, Dave
1987-01-01
The electro-optical characterization of gallium arsenide p/n solar cells is discussed. The objective is to identify and understand basic mechanisms which limit the performance of high efficiency gallium arsenide solar cells. The approach involves conducting photoresponse and temperature dependent current-voltage measurements, and interpretation of the data in terms of theory to determine key device parameters. Depth concentration profiles are also utilized in formulating a model to explain device performance.
A specification of 3D manipulation in virtual environments
NASA Technical Reports Server (NTRS)
Su, S. Augustine; Furuta, Richard
1994-01-01
In this paper we discuss the modeling of three basic kinds of 3-D manipulations in the context of a logical hand device and our virtual panel architecture. The logical hand device is a useful software abstraction representing hands in virtual environments. The virtual panel architecture is the 3-D component of the 2-D window systems. Both of the abstractions are intended to form the foundation for adaptable 3-D manipulation.
Developing Low-Noise GaAs JFETs For Cryogenic Operation
NASA Technical Reports Server (NTRS)
Cunningham, Thomas J.
1995-01-01
Report discusses aspects of effort to develop low-noise, low-gate-leakage gallium arsenide-based junction field-effect transistors (JFETs) for operation at temperature of about 4 K as readout amplifiers and multiplexing devices for infrared-imaging devices. Transistors needed to replace silicon transistors, relatively noisy at 4 K. Report briefly discusses basic physical principles of JFETs and describes continuing process of optimization of designs of GaAs JFETs for cryogenic operation.
Basic Research on Plasma Cathode for HPM Sources (NE - Luginsland)
2011-11-30
to NEPP Vacuum Pump for Mock Magnetron 12 (b) Borosilicate glass (Insulator) Anode Cathode Vacuum chamber Ion gauge controller Charge...channeling may be one physical mechanism that can explain the stability of the pinch in the discharge. (a) Scroll Pump High Voltage Power Supply DC... vacuum and/or low vacuum slow wave devices and cross field devices) in burst mode? Here, burst mode effectively implies an impulse-like (short pulse
NASA Technical Reports Server (NTRS)
Matus, Lawrence G.; Seng, Gary T.
1990-01-01
To meet the needs of the aerospace propulsion and space power communities, the high temperature electronics program at the Lewis Research Center is developing silicon carbide (SiC) as a high temperature semiconductor material. This program supports a major element of the Center's mission - to perform basic and developmental research aimed at improving aerospace propulsion systems. Research is focused on developing the crystal growth, characterization, and device fabrication technologies necessary to produce a family of SiC devices.
NASA Technical Reports Server (NTRS)
Winokur, P. S. (Editor)
1984-01-01
Radiation effects on electronic systems and devices (particularly spacecraft systems) are examined with attention given to such topics as radiation transport, energy deposition, and charge collection; single-event phenomena; basic mechanisms of radiation effects in structures and materials; and EMP phenomena. Also considered are radiation effects in integrated circuits, spacecraft charging and space radiation effects, hardness assurance for devices and systems, and SGEMP/IEMP phenomena.
Application of the Moment Method in the Slip and Transition Regime for Microfluidic Flows
2011-01-01
systems ( MEMS ), fluid flow at the micro- and nano-scale has received considerable attention [1]. A basic understanding of the nature of flow and heat ...Couette Flow Many MEMS devices contain oscillating parts where air (viscous) damping plays an important role. To understand the damping mechanisms...transfer in these devices is considered essential for efficient design and control of MEMS . Engineering applications for gas microflows include
Devices and Systems for Nonlinear Optical Information Processing
1988-11-01
in the VLSI literature [7, 8, 9], in which basic physical principles have been invoked to both understand current VLSI performance and to project...the first time, that in fact accounts for a very wide range of observed but previously unexplained phenomena [Appendix 4; AFOSR Jour. Publ. 7, AFOSR...the variable grating mode liquid crystal device A. R. Tongay. Jr. Abstract. The physical principles of operation of the variable grating mode C. S. Wu
An Experimental Device for Real Time Determination of Slant Path Atmospheric Contrast Transmittance.
1982-03-01
copies ftom th Defense Technical Information Caster. AN others ioM apply to the National Technical Information Service. UNCLASSIFIED SECURITV...EXPERIMENTAL DEVICE FOR REAL TIME DETERMINATION OF SLANT PATH ATMOSPHERIC CONTRAST TRANSMITTANCE Richard W. Johnson 1. INTRODUCTION 2. BASIC CONCEPTS As...and z is an altitude parameter. primary optical channel uses a cosine corrected and PE- ASSIG SYSTM DEPIS1ttt STAGE I DSIN STAGEM Pgormiy TES
Design considerations for imaging charge-coupled device
NASA Astrophysics Data System (ADS)
1981-04-01
The image dissector tube, which was formerly used as detector in star trackers, will be replaced by solid state imaging devices. The technology advances of charge transfer devices, like the charge-coupled device (CCD) and the charge-injection device (CID) have made their application to star trackers an immediate reality. The Air Force in 1979 funded an American Aerospace company to develop an imaging CCD (ICCD) star sensor for the Multimission Attitude Determination and Autonomous Navigation (MADAN) system. The MADAN system is a technology development for a strapdown attitude and navigation system which can be used on all Air Force 3-axis stabilized satellites. The system will be autonomous and will provide real-time satellite attitude and position information. The star sensor accuracy provides an overall MADAN attitude accuracy of 2 arcsec for star rates up to 300 arcsec/sec. The ICCD is basically an integrating device. Its pixel resolution in not yet satisfactory for precision applications.
NASA Astrophysics Data System (ADS)
Nikiforidis, Ioannis; Karafyllidis, Ioannis G.; Dimitrakis, Panagiotis
2018-02-01
Graphene p-n junctions could be the building blocks of future nanoelectronic circuits. While the conductance modulation of graphene p-n junctions formed in devices with one bottom and one top gate have received much attention, there is comparatively little work done on devices with two top gates. Here, we employ tight-bind Hamiltonians and non-equilibrium Green function method to compute in a systematic way the dependence of the conductance of graphene p-n junctions, formed in a device with two top gates, on the device parameters. We present our results in a compact and systematic way, so that the effect of each parameter is clearly shown. Our results show that the device conductance can be effectively modulated, and that graphene devices with two top gates may be used as basic elements in future carbon-based nanoelectronic circuits.
Older Homebound Women: Negotiating Reliance on a Cane or Walker
Porter, Eileen J.; Benson, Jacquelyn J.; Matsuda, Sandy
2012-01-01
Canes and walkers are commonly characterized as assistive devices and as devices that serve the same purpose, as walking aides. These general views were reappraised and tempered in this descriptive phenomenological study with 40 older women (aged 85-98) who were unable to leave their homes without help. The purpose was to describe the phenomena of negotiating reliance on canes and walkers as walking devices and the lifeworld context underlying each phenomenon. Relative to lifeworld, there were differences between coming to terms with using a cane and coming to terms with using a walker. Data revealed similarities and distinctions between the basic intentions of relying on canes and on walkers and the associated purposes served by canes and walkers. Participants did not view either device as consistently assistive. Findings evoke opportunities for dialogue among older persons, scholars, practitioners, and designers of these devices about coming to terms with such devices and relying on them. PMID:21041520
Hayakawa, Ryoma; Higashiguchi, Kenji; Matsuda, Kenji; Chikyow, Toyohiro; Wakayama, Yutaka
2013-11-13
We demonstrated optical manipulation of single-electron tunneling (SET) by photoisomerization of diarylethene molecules in a metal-insulator-semiconductor (MIS) structure. Stress is placed on the fact that device operation is realized in the practical device configuration of MIS structure and that it is not achieved in structures based on nanogap electrodes and scanning probe techniques. Namely, this is a basic memory device configuration that has the potential for large-scale integration. In our device, the threshold voltage of SET was clearly modulated as a reversible change in the molecular orbital induced by photoisomerization, indicating that diarylethene molecules worked as optically controllable quantum dots. These findings will allow the integration of photonic functionality into current Si-based memory devices, which is a unique feature of organic molecules that is unobtainable with inorganic materials. Our proposed device therefore has enormous potential for providing a breakthrough in Si technology.
48 CFR 239.7411 - Contract clauses.
Code of Federal Regulations, 2011 CFR
2011-10-01
... superseded. (d) Use the clause at 252.239-7016, Telecommunications Security Equipment, Devices, Techniques... OF DEFENSE SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF INFORMATION TECHNOLOGY Telecommunications... following clauses in solicitations, contracts, and basic agreements for telecommunications services. Modify...
Neutron radiation tolerance of Au-activated silicon
NASA Technical Reports Server (NTRS)
Joyner, W. T.
1987-01-01
Double injection devices prepared by the introduction of deep traps, using the Au activation method have been found to tolerate gamma irradiation into the Gigarad (Si) region without significant degradation of operating characteristics. Silicon double injection devices, using deep levels creacted by Au diffusion, can tolerate fast neutron irradiation up to 10 to the 15th n/sq cm. Significant parameter degradation occurs at 10 to the 16th n/sq cm. However, since the actual doping of the basic material begins to change as a result of the transmutation of silicon into phosphorus for neutron fluences greater than 10 to the 17th/sq cm, the radiation tolerance of these devices is approaching the limit possible for any device based on initially doped silicon.
High-power microwave LDMOS transistors for wireless data transmission technologies (Review)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, E. V., E-mail: E.Kouzntsov@tcen.ru; Shemyakin, A. V.
The fields of the application, structure, fabrication, and packaging technology of high-power microwave LDMOS transistors and the main advantages of these devices were analyzed. Basic physical parameters and some technology factors were matched for optimum device operation. Solid-state microwave electronics has been actively developed for the last 10-15 years. Simultaneously with improvement of old devices, new devices and structures are actively being adopted and developed and new semiconductor materials are being commercialized. Microwave LDMOS technology is in demand in such fields as avionics, civil and military radars, repeaters, base stations of cellular communication systems, television and broadcasting transmitters, and transceiversmore » for high-speed wireless computer networks (promising Wi-Fi and Wi-Max standards).« less
Design Issues of GaAs and AlGaAs Delta-Doped p-i-n Quantum-Well APD's
NASA Technical Reports Server (NTRS)
Wang, Yang
1994-01-01
We examine the basic design issues in the optimization of GaAs delta-doped and AlGAs delta-doped quantum-well avalanche photodiode (APD) structures using a theoretical analysis based on an ensemble Monte Carlo simulation. The devices are variations of the p-i-n doped quantum-well structure previously described in the literature. They have the same low-noise, high-gain and high-bandwidth features as the p-i-n doped quantum-well device. However, the use of delta doping provides far greater control or the doping concentrations within each stage possibly enhancing the extent to which the device can be depleted. As a result, it is expected that the proposed devices will operate at higher gain levels (at very low noise) than devices previously developed.
Momose, Naoki; Yamakoshi, Rie; Kokubo, Ryo; Yasuda, Toru; Iwamoto, Norio; Umeda, Chinori; Nakajima, Itsuro; Yanagisawa, Mitsunobu; Tomizawa, Yasuko
2010-03-01
We developed a simple device that stabilizes the blood level in the reservoir of the extracorporeal circulation open circuit system by measuring the hydrostatic pressure of the reservoir to control the flow rate of the arterial pump. When the flow rate of the venous return decreases, the rotation speed of the arterial pump is automatically slowed down. Consequently, the blood level in the reservoir is stabilized quickly between two arbitrarily set levels and never falls below the pre-set low level. We conducted a basic experiment to verify the operation of the device, using a mock circuit with water. Commercially available pumps and reservoir were used without modification. The results confirmed that the control method effectively regulates the reservoir liquid level and is highly reliable. The device possibly also functions as a safety device.
Integrated fountain effect pump device for fluid management at low gravity
NASA Technical Reports Server (NTRS)
Yuan, S. W. K.; Frank, D. J.
1988-01-01
A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.
Drugs and Medical Devices: Adverse Events and the Impact on Women’s Health
Carey, Jennifer L.; Nader, Nathalie; Chai, Peter R.; Carreiro, Stephanie; Griswold, Matthew K.; Boyle, Katherine L.
2018-01-01
A large number of medications and medical devices removed from the market by the US Food and Drug Administration over the past 4 decades specifically posed greater health risks to women. This article reviews the historical background of sex and gender in clinical research policy and describes several approved drugs and devices targeted for use in women that have caused major morbidity and mortality. The intended population for the medications and devices, population affected, approval process, and the basic and legal actions taken against the medication/drug company are also discussed. It is recognized that women are still at risk for harm from unsafe medications and devices, and continued improvements in legislation that promotes inclusion of sex and gender into the design and analysis of research will improve safety for both men and women. PMID:28069260
QUALITY ASSESSMENT OF CONFOCAL MICROSCOPY SLIDE-BASED SYSTEMS: INSTABLITY
Background: All slide-based fluorescence cytometry detections systems basically include an excitation light source, intermediate optics, and a detection device (CCD or PMT). Occasionally, this equipment becomes unstable, generating unreliable and inferior data. Methods: A num...
Turbo fluid machinery and diffusers
NASA Technical Reports Server (NTRS)
Sakurai, T.
1984-01-01
The general theory behind turbo devices and diffusers is explained. Problems and the state of research on basic equations of flow and experimental and measuring methods are discussed. Conventional centrifugation-type compressor and fan diffusers are considered in detail.
Lin, Feng; Tong, Xin; Wang, Yanan; Bao, Jiming; Wang, Zhiming M
2015-12-01
Graphene oxide (GO) liquid crystals (LCs) are macroscopically ordered GO flakes dispersed in water or polar organic solvents. Since the first report in 2011, GO LCs have attracted considerable attention for their basic properties and potential device applications. In this review, we summarize recent developments and present a comprehensive understanding of GO LCs via many aspects ranging from the exfoliation of GO flakes from graphite, to phases and phase transitions under various conditions, the orientational responses of GO under external magnetic and electric fields, and finally Kerr effect and display applications. The emphasis is placed on the unique and basic properties of GO and their ordered assembly. We will also discuss challenges and issues that need to be overcome in order to gain a more fundamental understanding and exploit full device potentials of GO LCs.
Advanced Energy Storage Devices: Basic Principles, Analytical Methods, and Rational Materials Design
Liu, Jilei; Wang, Jin; Xu, Chaohe; Li, Chunzhong; Lin, Jianyi
2017-01-01
Abstract Tremendous efforts have been dedicated into the development of high‐performance energy storage devices with nanoscale design and hybrid approaches. The boundary between the electrochemical capacitors and batteries becomes less distinctive. The same material may display capacitive or battery‐like behavior depending on the electrode design and the charge storage guest ions. Therefore, the underlying mechanisms and the electrochemical processes occurring upon charge storage may be confusing for researchers who are new to the field as well as some of the chemists and material scientists already in the field. This review provides fundamentals of the similarities and differences between electrochemical capacitors and batteries from kinetic and material point of view. Basic techniques and analysis methods to distinguish the capacitive and battery‐like behavior are discussed. Furthermore, guidelines for material selection, the state‐of‐the‐art materials, and the electrode design rules to advanced electrode are proposed. PMID:29375964
Liu, Jilei; Wang, Jin; Xu, Chaohe; Jiang, Hao; Li, Chunzhong; Zhang, Lili; Lin, Jianyi; Shen, Ze Xiang
2018-01-01
Tremendous efforts have been dedicated into the development of high-performance energy storage devices with nanoscale design and hybrid approaches. The boundary between the electrochemical capacitors and batteries becomes less distinctive. The same material may display capacitive or battery-like behavior depending on the electrode design and the charge storage guest ions. Therefore, the underlying mechanisms and the electrochemical processes occurring upon charge storage may be confusing for researchers who are new to the field as well as some of the chemists and material scientists already in the field. This review provides fundamentals of the similarities and differences between electrochemical capacitors and batteries from kinetic and material point of view. Basic techniques and analysis methods to distinguish the capacitive and battery-like behavior are discussed. Furthermore, guidelines for material selection, the state-of-the-art materials, and the electrode design rules to advanced electrode are proposed.
Thermoelectricity for future sustainable energy technologies
NASA Astrophysics Data System (ADS)
Weidenkaff, Anke
2017-07-01
Thermoelectricity is a general term for a number of effects describing the direct interconversion of heat and electricity. Thermoelectric devices are therefore promising, environmental-friendly alternatives to conventional power generators or cooling units. Since the mid-90s, research on thermoelectric properties and their applications has steadily increased. In the course of years, the development of high-temperature resistant TE materials and devices has emerged as one of the main areas of interest focusing both on basic research and practical applications. A wide range of innovative and cost-efficient material classes has been studied and their properties improved. This has also led to advances in synthesis and metrology. The paper starts out with thermoelectric history, basic effects underlying thermoelectric conversion and selected examples of application. The main part focuses on thermoelectric materials including an outline of the design rules, a review on the most common materials and the feasibility of improved future high-temperature thermoelectric converters.
In Situ Soil Venting - Full Scale Test, Hill AFB, Guidance Document. Volume 2
1991-08-01
oxidizer. Another system was connected to the existing air scrubber of a building (Reference 23). The self-contained unit reported by Rippberger...devices on the market for flow rate measurement. Some of the more common devices are orifice meters, venturi meters, rotameters, pitot tubes, hot-wire...Notes on how to size and construct orifice meters can be found in Reference 41. * Venturi Meter - A venturi meter works basically on the same
ERIC Educational Resources Information Center
Sharehu, Aminu Ladan; Emmanuel, Achor Edoja
2015-01-01
How prepared are teachers and pupils in Basic 6 (that is, 6th grade) to use Information and Communication Technology (ICT) such as mobile devices to aid teaching and learning in urban and rural schools at that level is a matter of concern and therefore formed the focus of this paper. The study is a survey of some urban and rural Primary schools in…
Combinatorial fabrication and screening of organic light-emitting device arrays
NASA Astrophysics Data System (ADS)
Shinar, Joseph; Shinar, Ruth; Zhou, Zhaoqun
2007-11-01
The combinatorial fabrication and screening of 2-dimensional (2-d) small molecular UV-violet organic light-emitting device (OLED) arrays, 1-d blue-to-red arrays, 1-d intense white OLED libraries, 1-d arrays to study Förster energy transfer in guest-host OLEDs, and 2-d arrays to study exciplex emission from OLEDs is described. The results demonstrate the power of combinatorial approaches for screening OLED materials and configurations, and for studying their basic properties.
Information Collection using Handheld Devices in Unreliable Networking Environments
2014-06-01
different types of mobile devices that connect wirelessly to a database 8 server. The actual backend database is not important to the mobile clients...Google’s infrastructure and local servers with MySQL and PostgreSQL on the backend (ODK 2014b). (2) Google Fusion Tables are used to do basic link...how we conduct business. Our requirements to share information do not change simply because there is little or no existing infrastructure in our
Means and Method for Measurement of Drilling Fluid Properties
NASA Astrophysics Data System (ADS)
Lysyannikov, A.; Kondrashov, P.; Pavlova, P.
2016-06-01
The paper addresses the problem on creation of a new design of the device for determining rheological parameters of drilling fluids and the basic requirements which it must meet. The key quantitative parameters that define the developed device are provided. The algorithm of determining the coefficient of the yield point from the rheological Shvedov- Bingam model at a relative speed of rotation of glasses from the investigated drilling fluid of 300 and 600 rpm is presented.
State-of-the-Art Study for High-speed Deceleration and Stabilization Devices
NASA Technical Reports Server (NTRS)
Alexander, W. C.; Lau, R. A.
1966-01-01
Documented aerodynamic deployable decelerator performance data above Mach 1. 0 is presented. The state of the art of drag and stability characteristics for reentry and recovery applications is defined for a wide range of decelerator configurations. Structural and material data and other design information also are presented. Emphasis is given to presentation of basic aero, thermal, and structural design data, which points out basic problem areas and voids in existing technology. The basic problems and voids include supersonic "buzzing" of towed porous decelerators in the wake of the forebody, the complete lack of dynamic stability data, and the general lack of aerothermal data at speeds above Mach 5.
Terrestrial Solar Spectral Modeling Tools and Applications for Photovoltaic Devices: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, D. R.; Emery, K. E.; Gueymard, C.
2002-05-01
This conference paper describes the variations in terrestrial spectral irradiance on photovoltaic devices can be an important consideration in photovoltaic device design and performance. This paper describes three available atmospheric transmission models, MODTRAN, SMARTS2, and SPCTRAL2. We describe the basics of their operation and performance, and applications in the photovoltaic community. Examples of model input and output data and comparisons between the model results for each under similar conditions are presented. The SMARTS2 model is shown to be much easier to use, as accurate as the complex MODTRAN model, and more accurate than the historical NREL SPCTRAL2 model.
Study of limitations and attributes of microprocessor testing techniques
NASA Technical Reports Server (NTRS)
Mccaskill, R.; Sohl, W. E.
1977-01-01
All microprocessor units have a similar architecture from which a basic test philosophy can be adopted and used to develop an approach to test each module separately in order to verify the functionality of each module within the device using the input/output pins of the device and its instruction set; test for destructive interaction between functional modules; and verify all timing, status information, and interrupt operations of the device. Block and test flow diagrams are given for the 8080, 8008, 2901, 6800, and 1802 microprocessors. Manufacturers are listed and problems encountered in testing the modules are discussed. Test equipment and methods are described.
Experimental Demonstration of xor Operation in Graphene Magnetologic Gates at Room Temperature
NASA Astrophysics Data System (ADS)
Wen, Hua; Dery, Hanan; Amamou, Walid; Zhu, Tiancong; Lin, Zhisheng; Shi, Jing; Žutić, Igor; Krivorotov, Ilya; Sham, L. J.; Kawakami, Roland K.
2016-04-01
We report the experimental demonstration of a magnetologic gate built on graphene at room temperature. This magnetologic gate consists of three ferromagnetic electrodes contacting a single-layer graphene spin channel and relies on spin injection and spin transport in the graphene. We utilize electrical bias tuning of spin injection to balance the inputs and achieve "exclusive or" (xor) logic operation. Furthermore, a simulation of the device performance shows that substantial improvement towards spintronic applications can be achieved by optimizing the device parameters such as the device dimensions. This advance holds promise as a basic building block for spin-based information processing.
BCB Bonding Technology of Back-Side Illuminated COMS Device
NASA Astrophysics Data System (ADS)
Wu, Y.; Jiang, G. Q.; Jia, S. X.; Shi, Y. M.
2018-03-01
Back-side illuminated CMOS(BSI) sensor is a key device in spaceborne hyperspectral imaging technology. Compared with traditional devices, the path of incident light is simplified and the spectral response is planarized by BSI sensors, which meets the requirements of quantitative hyperspectral imaging applications. Wafer bonding is the basic technology and key process of the fabrication of BSI sensors. 6 inch bonding of CMOS wafer and glass wafer was fabricated based on the low bonding temperature and high stability of BCB. The influence of different thickness of BCB on bonding strength was studied. Wafer bonding with high strength, high stability and no bubbles was fabricated by changing bonding conditions.
Yan, Guang; Zhao, Su-ling; Xu, Zheng; Zhang, Fu-jun; Kong, Chao; Liu, Xiao-dong; Gong, Wei; Gao, Li-yan
2011-07-01
Series of organic light emitting devices with basic structure of ITO/PCBM: PVK(x Wt%, approximately 40 nm)/DPVBi(30 nm)/Alq3 (30 nm)/Al were fabricated in order to investigate the carrier recombination region movement in these devices. The carrier injection-dependent, the carrier transport-dependent and the voltage-dependent carrier recombination region movements were investigated respectively by modifying cathode with lithium fluoride, by changing the doping concentration of PCBM and by changing the voltage on the devices. The physical mechanism behind the voltage-dependent carrier recombination region movement was discussed.
Analysis of space radiation data of semiconductor memories
NASA Technical Reports Server (NTRS)
Stassinopoulos, E. G.; Brucker, G. J.; Stauffer, C. A.
1996-01-01
This article presents an analysis of radiation effects for several select device types and technologies aboard the Combined Release and Radiation Effects Satellite (CRRES) satellite. These space-flight measurements covered a period of about 14 months of mission lifetime. Single Event Upset (SEU) data of the investigated devices from the Microelectronics Package (MEP) were processed and analyzed. Valid upset measurements were determined by correcting for invalid readings, hard failures, missing data tapes (thus voids in data), and periods over which devices were disabled from interrogation. The basic resolution time of the measurement system was confirmed to be 2 s. Lessons learned, important findings, and recommendations are presented.
Remote artificial eyes using micro-optical circuit for long-distance 3D imaging perception.
Thammawongsa, Nopparat; Yupapin, Preecha P
2016-01-01
A small-scale optical device incorporated with an optical nano-antenna is designed to operate as the remote artificial eye using a tiny conjugate mirror. A basic device known as a conjugate mirror can be formed using the artificial eye device, the partially reflected light intensities from input source are interfered and the 3D whispering gallery modes formed within the ring centers, which can be modulated and propagated to the object. The image pixel is obtained at the center ring and linked with the optic nerve in the remote area via the nano-antenna, which is useful for blind people.
Recent Advancements in Functionalized Paper-Based Electronics.
Lin, Yang; Gritsenko, Dmitry; Liu, Qian; Lu, Xiaonan; Xu, Jie
2016-08-17
Building electronic devices on ubiquitous paper substrates has recently drawn extensive attention due to its light weight, low cost, environmental friendliness, and ease of fabrication. Recently, a myriad of advancements have been made to improve the performance of paper electronics for various applications, such as basic electronic components, energy storage devices, generators, antennas, and electronic circuits. This review aims to summarize this progress and discuss different perspectives of paper electronics as well as the remaining challenges yet to be overcome in this field. Other aspects included in this review are the fundamental characteristics of paper, modification of paper with functional materials, and various methods for device fabrication.
NASA Astrophysics Data System (ADS)
Sokoloski, Martin M.
1988-09-01
The objective of the Communications Technology Program is to enable data transmission to and from low Earth orbit, geostationary orbit, and solar and deep space missions. This can be achieved by maintaining an effective, balances effort in basic, applied, and demonstration prototype communications technology through work in theory, experimentation, and components. The program consists of three major research and development discipline areas which are: microwave and millimeter wave tube components; solid state monolithic integrated circuit; and free space laser communications components and devices. The research ranges from basic research in surface physics (to study the mechanisms of surface degradation from under high temperature and voltage operating conditions which impacts cathode tube reliability and lifetime) to generic research on the dynamics of electron beams and circuits (for exploitation in various micro- and millimeter wave tube devices). Work is also performed on advanced III-V semiconductor materials and devices for use in monolithic integrated analog circuits (used in adaptive, programmable phased arrays for microwave antenna feeds and receivers) - on the use of electromagnetic theory in antennas and on technology necessary for eventual employment of lasers for free space communications for future low earth, geostationary, and deep space missions requiring high data rates with corresponding directivity and reliability.
NASA Technical Reports Server (NTRS)
Sokoloski, Martin M.
1988-01-01
The objective of the Communications Technology Program is to enable data transmission to and from low Earth orbit, geostationary orbit, and solar and deep space missions. This can be achieved by maintaining an effective, balances effort in basic, applied, and demonstration prototype communications technology through work in theory, experimentation, and components. The program consists of three major research and development discipline areas which are: microwave and millimeter wave tube components; solid state monolithic integrated circuit; and free space laser communications components and devices. The research ranges from basic research in surface physics (to study the mechanisms of surface degradation from under high temperature and voltage operating conditions which impacts cathode tube reliability and lifetime) to generic research on the dynamics of electron beams and circuits (for exploitation in various micro- and millimeter wave tube devices). Work is also performed on advanced III-V semiconductor materials and devices for use in monolithic integrated analog circuits (used in adaptive, programmable phased arrays for microwave antenna feeds and receivers) - on the use of electromagnetic theory in antennas and on technology necessary for eventual employment of lasers for free space communications for future low earth, geostationary, and deep space missions requiring high data rates with corresponding directivity and reliability.
NASA Astrophysics Data System (ADS)
Gandhi, Om P.; Kang, Gang
2001-11-01
This paper illustrates the use of the impedance method to calculate the electric fields and current densities induced in millimetre resolution anatomic models of the human body, namely an adult and 10- and 5-year-old children, for exposure to nonuniform magnetic fields typical of two assumed but representative electronic article surveillance (EAS) devices at 1 and 30 kHz, respectively. The devices assumed for the calculations are a solenoid type magnetic deactivator used at store checkouts and a pass-by panel-type EAS system consisting of two overlapping rectangular current-carrying coils used at entry and exit from a store. The impedance method code is modified to obtain induced current densities averaged over a cross section of 1 cm2 perpendicular to the direction of induced currents. This is done to compare the peak current densities with the limits or the basic restrictions given in the ICNIRP safety guidelines. Because of the stronger magnetic fields at lower heights for both the assumed devices, the peak 1 cm2 area-averaged current densities for the CNS tissues such as the brain and the spinal cord are increasingly larger for smaller models and are the highest for the model of the 5-year-old child. For both the EAS devices, the maximum 1 cm2 area-averaged current densities for the brain of the model of the adult are lower than the ICNIRP safety guideline, but may approach or exceed the ICNIRP basic restrictions for models of 10- and 5-year-old children if sufficiently strong magnetic fields are used.
Gandhi, O P; Kang, G
2001-11-01
This paper illustrates the use of the impedance method to calculate the electric fields and current densities induced in millimetre resolution anatomic models of the human body, namely an adult and 10- and 5-year-old children, for exposure to nonuniform magnetic fields typical of two assumed but representative electronic article surveillance (EAS) devices at 1 and 30 kHz, respectively. The devices assumed for the calculations are a solenoid type magnetic deactivator used at store checkouts and a pass-by panel-type EAS system consisting of two overlapping rectangular current-carrying coils used at entry and exit from a store. The impedance method code is modified to obtain induced current densities averaged over a cross section of 1 cm2 perpendicular to the direction of induced currents. This is done to compare the peak current densities with the limits or the basic restrictions given in the ICNIRP safety guidelines. Because of the stronger magnetic fields at lower heights for both the assumed devices, the peak 1 cm2 area-averaged current densities for the CNS tissues such as the brain and the spinal cord are increasingly larger for smaller models and are the highest for the model of the 5-year-old child. For both the EAS devices, the maximum 1 cm2 area-averaged current densities for the brain of the model of the adult are lower than the ICNIRP safety guideline, but may approach or exceed the ICNIRP basic restrictions for models of 10- and 5-year-old children if sufficiently strong magnetic fields are used.
Sato, Yasuhiko; Oba, Takuma; Danjo, Kazumi
2013-01-01
We have discussed the essential property for periodontal disease medication using protein, such as recombinant human basic fibroblast growth factor (rhbFGF). In our previous study, the criteria of thickener for the medication, viscosity, flowability etc., were set. The aim of this study was to evaluate the physical and chemical effect of concomitant use of general dental drug or device on thickener properties for the clinical use of viscous rhbFGF formulation. Viscous formulation was prepared with six cellulose derivatives, two types hydroxy propyl cellulose (HPC), three types hydroxy ethyl cellulose (HEC) and methyl cellulose (MC). Antibiotic ointment, local anesthetic, bone graft substitute, agent for gargle and mouthwashes, were chosen as general dental drug and device. These drugs and device were mixed with the viscous formulations and the change of viscosity and flowability, the remaining ratio of rhbFGF were evaluated. When the various thickener solutions were mixed with the liquid drugs, viscosity and flowability did not changed much. However, in the case of MC solution, viscous property declined greatly when MC solution was mixed with cationic surfactant for gargle. The flowabilities of thickener solutions were declined with insoluble bone graft. The stabilities of rhbFGF in thickener solutions were no problem for 24 hours even in the case of mixing with dental drug or device. Our findings suggested that the viscous rhbFGF formulations prepared in this research were not substantially affected by the concomitant use of dental drug or device, especially the formulation with HPC or HEC was useful.
Development of very large electrode arrays for epiretinal stimulation (VLARS)
2014-01-01
Background Retinal implants have been developed to treat blindness causing retinal degenerations such as Retinitis pigmentosa (RP). The retinal stimulators are covering only a small portion of the retina usually in its center. To restore not only central vision but also a useful visual field retinal stimulators need to cover a larger area of the retina. However, large area retinal stimulators are much more difficult to implant into an eye. Some basic questions concerning this challenge should be answered in a series of experiments. Methods Large area retinal stimulators were fabricated as flexible multielectrode arrays (MEAs) using silicon technology with polyimide as the basic material for the substrate. Electrodes were made of gold covered with reactively sputtered iridium oxide. Several prototype designs were considered and implanted into enucleated porcine eyes. The prototype MEAs were also used as recording devices. Results Large area retinal stimulator MEAs were fabricated with a diameter of 12 mm covering a visual angle of 37.6° in a normal sighted human eye. The structures were flexible enough to be implanted in a folded state through an insertion nozzle. The implants could be positioned onto the retinal surface and fixated here using a retinal tack. Recording of spontaneous activity of retinal neurons was possible in vitro using these devices. Conclusions Large flexible MEAs covering a wider area of the retina as current devices could be fabricated using silicon technology with polyimide as a base material. Principal surgical techniques were established to insert such large devices into an eye and the devices could also be used for recording of retinal neural activity. PMID:24502253
ERIC Educational Resources Information Center
Joyner, Jeane; Leiva, Miriam
1988-01-01
Plastic Easter eggs are useful devices for teaching basic mathematics skills, from counting activities to graphing. Eggs are used to reinforce addition, subtraction, and multiplication skills; column addition, estimation, statistics, and other topics are introduced. Sample activities are described. (JL)
Laser interferometry method for absolute measurement of the acceleration of gravity
NASA Technical Reports Server (NTRS)
Hudson, O. K.
1971-01-01
Gravimeter permits more accurate and precise absolute measurement of g without reference to Potsdam values as absolute standards. Device is basically Michelson laser beam interferometer in which one arm is mass fitted with corner cube reflector.
Radionuclide Basics: Cesium-137
The most common radioactive form of cesium (chemical symbol Cs) is Cesium-137. Cesium-137 is produced by nuclear fission for use in medical devices and gauges and is one of the byproducts of nuclear fission in nuclear reactors and nuclear weapons testing.
DOT National Transportation Integrated Search
2010-08-01
Radio frequency identification device (RFID) technology provides the capability to store a unique identification : number and some basic attribute information, which can be retrieved wirelessly. This research project studied : the feasibility of usin...
Design and performance characteristics of a mechanically driven vestibular stimulator.
DOT National Transportation Integrated Search
1964-01-01
In order to determine basic response characteristics of mammalian vestibular systems, the sytems so important for spatial orientation, a device to provide programs of controlled angular accelerations about the vertical axis was required. The small ro...
Kragic, Rastislav; Kostic, Mirjana
2018-01-01
In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source “OpenPhControl” software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device’s utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary. PMID:29509793
Susceptibility study of audio recording devices to electromagnetic stimulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halligan, Matthew S.; Grant, Steven L.; Beetner, Daryl G.
2014-02-01
Little research has been performed to study how intentional electromagnetic signals may couple into recording devices. An electromagnetic susceptibility study was performed on an analog tape recorder, a digital video camera, a wired computer microphone, and a wireless microphone system to electromagnetic interference. Devices were subjected to electromagnetic stimulations in the frequency range of 1-990 MHz and field strengths up to 4.9 V/m. Carrier and message frequencies of the stimulation signals were swept, and the impacts of device orientation and antenna polarization were explored. Message signals coupled into all devices only when amplitude modulated signals were used as stimulation signals.more » Test conditions that produced maximum sensitivity were highly specific to each device. Only narrow carrier frequency ranges could be used for most devices to couple messages into recordings. A basic detection technique using cross-correlation demonstrated the need for messages to be as long as possible to maximize message detection and minimize detection error. Analysis suggests that detectable signals could be coupled to these recording devices under realistic ambient conditions.« less
A Transportable VLF/LF Repeater Terminal - A Design Study,
1986-07-01
Corporation and marketed commercially as the ROLM 1602B, is expected to be used on the Airborne Command Post (ABNCP) fleet for MMPM processing. The basic...A suitable keyboard/printer for this application is a solid state teletype, the AN/ UGC -120. This device can also function as an AFSATCOM terminal...and as the VLF output device in the event of CPU failure. The AN/ UGC -120 is an Air Force inventory item. 20 INTERSITE COW4UNICATIONS SUBSYSTEM A single
Raman Shifted Nd:YAG Class I Eye-Safe Laser Development 21 January 1986
NASA Astrophysics Data System (ADS)
Nichols, R. W.; Ng, W. K.
1986-07-01
Hughes Aircraft has been developing a hand-held eye-safe laser rangefinder fo1r the Army utilizing Stimulated Raman Scattering technology. The device uses the 2915 cm-1 vibrational mode of methane (CH4) to wavelength shift the Nd:YAG pump laser's 1.064 micron to an eye-safe 1.543 micron. The result is a lightweight BRH Class I eye-safe tactical device. A brief description of Raman wavelength shifting basics is followed by description of the Hughes system.
The Remote Detection of Alpha-Radioactive Nucleus Decay
NASA Astrophysics Data System (ADS)
Gurkovskiy, Boris; Miroshnichenko, Vladimir; Onishchenko, Evgeny; Simakov, Andrey; Streil, Thomas
Results of the new device design for the alpha-radiation remote detection are presented. Negative ions from the alpha particle tracks are detected by the discharge wire counter opened to air. Ion clusters being transferred from the particle tracks to the detector volume by an air flux. The detector works in a counting mode that provides sharp selectivity and accuracy of measurements. The basic parameters of the device are: detecting distance -0.5 m; measurement time -30 s; the square sensitivity -0.05 Bq/cm2.
Joint services electronics program
NASA Astrophysics Data System (ADS)
Flynn, George W.; Osgood, Richard M., Jr.
1988-05-01
Several milestones have been reached in GaAs research. The first active GaAs device, a 1 micrometer channel width MESFET, has been made at Columbia. This device is a basic building block in the GaAs CCD program. GaAs surface studies have also born fruit. UV light has been found to oxidize rapidly the surface of GaAs in an UHV environment containing traces of water vapor and O2. The mechanism appears to be related to the generation of hot photocarriers.
Organic membrane photonic integrated circuits (OMPICs).
Amemiya, Tomohiro; Kanazawa, Toru; Hiratani, Takuo; Inoue, Daisuke; Gu, Zhichen; Yamasaki, Satoshi; Urakami, Tatsuhiro; Arai, Shigehisa
2017-08-07
We propose the concept of organic membrane photonic integrated circuits (OMPICs), which incorporate various functions needed for optical signal processing into a flexible organic membrane. We describe the structure of several devices used within the proposed OMPICs (e.g., transmission lines, I/O couplers, phase shifters, photodetectors, modulators), and theoretically investigate their characteristics. We then present a method of fabricating the photonic devices monolithically in an organic membrane and demonstrate the operation of transmission lines and I/O couplers, the most basic elements of OMPICs.
Low-cost data analysis systems for processing multispectral scanner data
NASA Technical Reports Server (NTRS)
Whitely, S. L.
1976-01-01
The basic hardware and software requirements are described for four low cost analysis systems for computer generated land use maps. The data analysis systems consist of an image display system, a small digital computer, and an output recording device. Software is described together with some of the display and recording devices, and typical costs are cited. Computer requirements are given, and two approaches are described for converting black-white film and electrostatic printer output to inexpensive color output products. Examples of output products are shown.
Integration of pyrotechnics into aerospace systems
NASA Technical Reports Server (NTRS)
Bement, Laurence J.; Schimmel, Morry L.
1993-01-01
The application of pyrotechnics to aerospace systems has been resisted because normal engineering methods cannot be used in design and evaluation. Commonly used approaches for energy sources, such as electrical, hydraulic and pneumatic, do not apply to explosive and pyrotechnic devices. This paper introduces the unique characteristics of pyrotechnic devices, describes how functional evaluations can be conducted, and demonstrates an engineering approach for pyrotechnic integration. Logic is presented that allows evaluation of two basic types of pyrotechnic systems to demonstrate functional margin.
Drugs and Medical Devices: Adverse Events and the Impact on Women's Health.
Carey, Jennifer L; Nader, Nathalie; Chai, Peter R; Carreiro, Stephanie; Griswold, Matthew K; Boyle, Katherine L
2017-01-01
A large number of medications and medical devices removed from the market by the US Food and Drug Administration over the past 4 decades specifically posed greater health risks to women. This article reviews the historical background of sex and gender in clinical research policy and describes several approved drugs and devices targeted for use in women that have caused major morbidity and mortality. The intended population for the medications and devices, population affected, approval process, and the basic and legal actions taken against the medication/drug company are also discussed. It is recognized that women are still at risk for harm from unsafe medications and devices, and continued improvements in legislation that promotes inclusion of sex and gender into the design and analysis of research will improve safety for both men and women. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.
Older homebound women: negotiating reliance on a cane or walker.
Porter, Eileen J; Benson, Jacquelyn J; Matsuda, Sandy
2011-04-01
Canes and walkers are commonly characterized as assistive devices that serve the same purpose: as walking aides. These general views were reappraised and tempered in this descriptive phenomenological study with 40 older women (aged 85 to 98 years) who were unable to leave their homes without help. The purpose was to describe the phenomena of negotiating reliance on canes and walkers as walking devices and the lifeworld context underlying each phenomenon. Relative to lifeworld, there were differences between coming to terms with using a cane and coming to terms with using a walker. Data revealed similarities and distinctions between the basic intentions of relying on canes and walkers and the associated purposes served by canes and walkers. Participants did not view either device as consistently assistive. Findings evoke opportunities for dialogue among older persons, scholars, practitioners, and designers of these devices about coming to terms with such devices and relying on them.
Toward biomaterial-based implantable photonic devices
NASA Astrophysics Data System (ADS)
Humar, Matjaž; Kwok, Sheldon J. J.; Choi, Myunghwan; Yetisen, Ali K.; Cho, Sangyeon; Yun, Seok-Hyun
2017-03-01
Optical technologies are essential for the rapid and efficient delivery of health care to patients. Efforts have begun to implement these technologies in miniature devices that are implantable in patients for continuous or chronic uses. In this review, we discuss guidelines for biomaterials suitable for use in vivo. Basic optical functions such as focusing, reflection, and diffraction have been realized with biopolymers. Biocompatible optical fibers can deliver sensing or therapeutic-inducing light into tissues and enable optical communications with implanted photonic devices. Wirelessly powered, light-emitting diodes (LEDs) and miniature lasers made of biocompatible materials may offer new approaches in optical sensing and therapy. Advances in biotechnologies, such as optogenetics, enable more sophisticated photonic devices with a high level of integration with neurological or physiological circuits. With further innovations and translational development, implantable photonic devices offer a pathway to improve health monitoring, diagnostics, and light-activated therapies.
Designing a Double-Pole Nanoscale Relay Based on a Carbon Nanotube: A Theoretical Study
NASA Astrophysics Data System (ADS)
Mu, Weihua; Ou-Yang, Zhong-can; Dresselhaus, Mildred S.
2017-08-01
We theoretically investigate a novel and powerful double-pole nanoscale relay based on a carbon nanotube, which is one of the nanoelectromechanical switches being able to work under the strong nuclear radiation, and analyze the physical mechanism of the operating stages in the operation, including "pull in," "connection," and "pull back," as well as the key factors influencing the efficiency of the devices. We explicitly provide the analytical expression of the two important operation voltages, Vpull in and Vpull back , therefore clearly showing the dependence of the material properties and geometry of the present devices by the analytical method from basic physics, avoiding complex numerical calculations. Our method is easy to use in preparing the design guide for fabricating the present device and other nanoelectromechanical devices.
Effect of doping on all TMC vertical heterointerfaces
NASA Astrophysics Data System (ADS)
Nair, Salil; Joy, Jolly; Patel, K. D.; Pataniya, Pratik; Solanki, G. K.; Pathak, V. M.; Sumesh, C. K.
2018-05-01
The present work reports the growth and basic characterizations of GeSePbx (x=0, 0.02, 0.04) layered mono chalcogenide single crystal substrates for preparation of heterojunction devices. These crystals are grown by Direct Vapour Transport (DVT) Technique [1,2]. Heterojunction interfaces on these substrates are prepared using thermal evaporation of nanocrystalline SnSe thin films having 5kÅ thickness. The electrical characterizations reveal the rectifying behavior of the devices based on which its ideality factor, barrier height, saturation current, series resistance etc. have been determined using thermionic emission model [3,4]. The device parameters have been determined and analyzed by three different methods viz. LnI-V, Cheung's method and Norde method [5]. The variation in the device parameters in light of doping is reported in the present work.
Monolithic integration of SOI waveguide photodetectors and transimpedance amplifiers
NASA Astrophysics Data System (ADS)
Li, Shuxia; Tarr, N. Garry; Ye, Winnie N.
2018-02-01
In the absence of commercial foundry technologies offering silicon-on-insulator (SOI) photonics combined with Complementary Metal Oxide Semiconductor (CMOS) transistors, monolithic integration of conventional electronics with SOI photonics is difficult. Here we explore the implementation of lateral bipolar junction transistors (LBJTs) and Junction Field Effect Transistors (JFETs) in a commercial SOI photonics technology lacking MOS devices but offering a variety of n- and p-type ion implants intended to provide waveguide modulators and photodetectors. The fabrication makes use of the commercial Institute of Microelectronics (IME) SOI photonics technology. Based on knowledge of device doping and geometry, simple compact LBJT and JFET device models are developed. These models are then used to design basic transimpedance amplifiers integrated with optical waveguides. The devices' experimental current-voltage characteristics results are reported.
Effects of ultrathin oxides in conducting MIS structures on GaAs
NASA Technical Reports Server (NTRS)
Childs, R. B.; Ruths, J. M.; Sullivan, T. E.; Fonash, S. J.
1978-01-01
Schottky barrier-type GaAs baseline devices (semiconductor surface etched and then immediately metalized) and GaAs conducting metal oxide-semiconductor devices are fabricated and characterized. The baseline surfaces (no purposeful oxide) are prepared by a basic or an acidic etch, while the surface for the MIS devices are prepared by oxidizing after the etch step. The metallizations used are thin-film Au, Ag, Pd, and Al. It is shown that the introduction of purposeful oxide into these Schottky barrier-type structures examined on n-type GaAs modifies the barrier formation, and that thin interfacial layers can modify barrier formation through trapping and perhaps chemical reactions. For Au- and Pd-devices, enhanced photovoltaic performance of the MIS configuration is due to increased barrier height.
Microcontroller for automation application
NASA Technical Reports Server (NTRS)
Cooper, H. W.
1975-01-01
The description of a microcontroller currently being developed for automation application was given. It is basically an 8-bit microcomputer with a 40K byte random access memory/read only memory, and can control a maximum of 12 devices through standard 15-line interface ports.
Microfluidic tools for cell biological research
Velve-Casquillas, Guilhem; Le Berre, Maël; Piel, Matthieu; Tran, Phong T.
2010-01-01
Summary Microfluidic technology is creating powerful tools for cell biologists to control the complete cellular microenvironment, leading to new questions and new discoveries. We review here the basic concepts and methodologies in designing microfluidic devices, and their diverse cell biological applications. PMID:21152269
Resources for the Visually Impaired.
ERIC Educational Resources Information Center
Oseroff, Andrew; And Others
1987-01-01
Suggestions for resource room teachers working with visually impaired learning disabled students include: consideration of students' unique learning needs; assessment of functional vision; use of assistive devices (such as closed-circuit television); classroom arrangement that facilitates organization and movement; and basic skills instruction…
Travel assistance device deployment to transit agencies.
DOT National Transportation Integrated Search
2010-08-01
The ability to travel where and when one desires is a basic requirement for independent living that most people take for granted. To travel independently, a transit rider practices at least 23 skills including finding the route, arriving at the corre...
AN AUTOMATIC DEVICE FOR READING TYPOGRAPHICAL TEXTS,
permissible. The system represents an attempt to apply the methods of machines designed for typescript reading to machines reading printed texts...Some characteristics by which typescript and typographical material differ are presented. The basic aspects of the recognition algorithm are given. A
Superconductivity: Recent Developments and Defence Applications
1988-03-11
resonance tomography ; quantum interferometers used in detectors for research into biomagnetism and gravitational waves; and analogue electronics devices...has looked at muon spin rotation measurements of the penetration depth of magnetic fields into the superconductors. Basic research is under way at Chalk
RESTRAINING SYSTEM FOR PLETHYSMOGRAPHY IN SMALL ANIMALS
A restraining technique for immobilizing awake guinea pigs and rats during physiological measurements is described. The basic device consists of an adjustable acrylic holder that supports the animal in a standing position while restricting movement of the four legs. The holder al...
Thermodynamic limits to the efficiency of solar energy conversion by quantum devices
NASA Technical Reports Server (NTRS)
Buoncristiani, A. M.; Byvik, C. E.; Smith, B. T.
1981-01-01
The second law of thermodynamics imposes a strict limitation to the energy converted from direct solar radiation to useful work by a quantum device. This limitation requires that the amount of energy converted to useful work (energy in any form other than heat) can be no greater than the change in free energy of the radiation fields. Futhermore, in any real energy conversion device, not all of this available free energy in the radiation field can be converted to work because of basic limitations inherent in the device itself. A thermodynamic analysis of solar energy conversion by a completely general prototypical quantum device is presented. This device is completely described by two parameters, its operating temperature T sub R and the energy threshold of its absorption spectrum. An expression for the maximum thermodynamic efficiency of a quantum solar converter was derived in terms of these two parameters and the incident radiation spectrum. Efficiency curves for assumed solar spectral irradiance corresponding to air mass zero and air mass 1.5 are presented.
Osterloh, Frank E.
2017-01-18
Here, the chemical literature often does not differentiate between photocatalytic (PC) and photosynthetic (PS) processes (including artificial photosynthesis) even though these reactions differ in their thermodynamics. Photocatalytic processes are thermodynamically downhill (ΔG < 0) and are merely accelerated by the catalyst, whereas photosynthetic processes are thermodynamically unfavorable (ΔG > 0) and require photochemical energy input to occur. Here we apply this differentiation to analyze the basic functions of PC and PS devices and to formulate design criteria for improved performance. As will be shown, the corresponding devices exhibit distinctly different sensitivities to their functional parameters. For example, under conditions ofmore » optimal light absorption, carrier lifetimes, and electrochemical rates, the performance of PCs is limited only by their surface area, while type 1 PS devices are limited by their carrier mobility and mass transport, and type 2 PS devices are limited by electrochemical charge-transfer selectivity. Strategies for the optimization of type 1 and 2 photosynthetic devices and photocatalysts are also discussed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Osterloh, Frank E.
Here, the chemical literature often does not differentiate between photocatalytic (PC) and photosynthetic (PS) processes (including artificial photosynthesis) even though these reactions differ in their thermodynamics. Photocatalytic processes are thermodynamically downhill (ΔG < 0) and are merely accelerated by the catalyst, whereas photosynthetic processes are thermodynamically unfavorable (ΔG > 0) and require photochemical energy input to occur. Here we apply this differentiation to analyze the basic functions of PC and PS devices and to formulate design criteria for improved performance. As will be shown, the corresponding devices exhibit distinctly different sensitivities to their functional parameters. For example, under conditions ofmore » optimal light absorption, carrier lifetimes, and electrochemical rates, the performance of PCs is limited only by their surface area, while type 1 PS devices are limited by their carrier mobility and mass transport, and type 2 PS devices are limited by electrochemical charge-transfer selectivity. Strategies for the optimization of type 1 and 2 photosynthetic devices and photocatalysts are also discussed.« less
Sher, Mazhar; Zhuang, Rachel; Demirci, Utkan; Asghar, Waseem
2017-01-01
Introduction There is a significant interest in developing inexpensive portable biosensing platforms for various applications including disease diagnostics, environmental monitoring, food safety, and water testing at the point-of-care (POC) settings. Current diagnostic assays available in the developed world require sophisticated laboratory infrastructure and expensive reagents. Hence, they are not suitable for resource-constrained settings with limited financial resources, basic health infrastructure, and few trained technicians. Cellulose and flexible transparency paper-based analytical devices have demonstrated enormous potential for developing robust, inexpensive and portable devices for disease diagnostics. These devices offer promising solutions to disease management in resource-constrained settings where the vast majority of the population cannot afford expensive and highly sophisticated treatment options. Areas covered In this review, the authors describe currently developed cellulose and flexible transparency paper-based microfluidic devices, device fabrication techniques, and sensing technologies that are integrated with these devices. The authors also discuss the limitations and challenges associated with these devices and their potential in clinical settings. Expert commentary In recent years, cellulose and flexible transparency paper-based microfluidic devices have demonstrated the potential to become future healthcare options despite a few limitations such as low sensitivity and reproducibility. PMID:28103450
Sher, Mazhar; Zhuang, Rachel; Demirci, Utkan; Asghar, Waseem
2017-04-01
There is a significant interest in developing inexpensive portable biosensing platforms for various applications including disease diagnostics, environmental monitoring, food safety, and water testing at the point-of-care (POC) settings. Current diagnostic assays available in the developed world require sophisticated laboratory infrastructure and expensive reagents. Hence, they are not suitable for resource-constrained settings with limited financial resources, basic health infrastructure, and few trained technicians. Cellulose and flexible transparency paper-based analytical devices have demonstrated enormous potential for developing robust, inexpensive and portable devices for disease diagnostics. These devices offer promising solutions to disease management in resource-constrained settings where the vast majority of the population cannot afford expensive and highly sophisticated treatment options. Areas covered: In this review, the authors describe currently developed cellulose and flexible transparency paper-based microfluidic devices, device fabrication techniques, and sensing technologies that are integrated with these devices. The authors also discuss the limitations and challenges associated with these devices and their potential in clinical settings. Expert commentary: In recent years, cellulose and flexible transparency paper-based microfluidic devices have demonstrated the potential to become future healthcare options despite a few limitations such as low sensitivity and reproducibility.
Basic materials physics of transparent conducting oxides.
Edwards, P P; Porch, A; Jones, M O; Morgan, D V; Perks, R M
2004-10-07
Materials displaying the remarkable combination of high electrical conductivity and optical transparency already from the basis of many important technological applications, including flat panel displays, solar energy capture and other opto-electronic devices. Here we present the basic materials physics of these important materials centred on the nature of the doping process to generate n-type conductivity in transparent conducting oxides, the associated transition to the metallic (conducting) state and the detailed properties of the degenerate itinerant electron gas. The aim is to fully understand the origins of the basic performance limits of known materials and to set the scene for new or improved materials which will breach those limits for new-generation transparent conducting materials, either oxides, or beyond oxides.
GenASiS Basics: Object-oriented utilitarian functionality for large-scale physics simulations
Cardall, Christian Y.; Budiardja, Reuben D.
2015-06-11
Aside from numerical algorithms and problem setup, large-scale physics simulations on distributed-memory supercomputers require more basic utilitarian functionality, such as physical units and constants; display to the screen or standard output device; message passing; I/O to disk; and runtime parameter management and usage statistics. Here we describe and make available Fortran 2003 classes furnishing extensible object-oriented implementations of this sort of rudimentary functionality, along with individual `unit test' programs and larger example problems demonstrating their use. Lastly, these classes compose the Basics division of our developing astrophysics simulation code GenASiS (General Astrophysical Simulation System), but their fundamental nature makes themmore » useful for physics simulations in many fields.« less
Characterization of basic physical properties of Sb 2Se 3 and its relevance for photovoltaics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Chao; Bobela, David C.; Yang, Ye
Antimony selenide (Sb 2Se 3) is a promising absorber material for thin film photovoltaics because of its attractive material, optical and electrical properties. In recent years, the power conversion efficiency (PCE) of Sb 2Se 3 thin film solar cells has gradually enhanced to 5.6%. In this article, we systematically studied the basic physical properties of Sb 2Se 3 such as dielectric constant, anisotropic mobility, carrier lifetime, diffusion length, defect depth, defect density and optical band tail states. Here, we believe such a comprehensive characterization of the basic physical properties of Sb 2Se 3 lays a solid foundation for further optimizationmore » of solar device performance.« less
Characterization of basic physical properties of Sb 2Se 3 and its relevance for photovoltaics
Chen, Chao; Bobela, David C.; Yang, Ye; ...
2017-03-17
Antimony selenide (Sb 2Se 3) is a promising absorber material for thin film photovoltaics because of its attractive material, optical and electrical properties. In recent years, the power conversion efficiency (PCE) of Sb 2Se 3 thin film solar cells has gradually enhanced to 5.6%. In this article, we systematically studied the basic physical properties of Sb 2Se 3 such as dielectric constant, anisotropic mobility, carrier lifetime, diffusion length, defect depth, defect density and optical band tail states. Here, we believe such a comprehensive characterization of the basic physical properties of Sb 2Se 3 lays a solid foundation for further optimizationmore » of solar device performance.« less
Cone beam computed tomography: basics and applications in dentistry.
Venkatesh, Elluru; Elluru, Snehal Venkatesh
2017-01-01
The introduction of cone beam computed tomography (CBCT) devices, changed the way oral and maxillofacial radiology is practiced. CBCT was embraced into the dental settings very rapidly due to its compact size, low cost, low ionizing radiation exposure when compared to medical computed tomography. Alike medical CT, 3 dimensional evaluation of the maxillofacial region with minimal distortion is offered by the CBCT. This article provides an overview of basics of CBCT technology and reviews the specific application of CBCT technology to oral and maxillofacial region with few illustrations.
SCP -- A Simple CCD Processing Package
NASA Astrophysics Data System (ADS)
Lewis, J. R.
This note describes a small set of programs, written at RGO, which deal with basic CCD frame processing (e.g. bias subtraction, flat fielding, trimming etc.). The need to process large numbers of CCD frames from devices such as FOS or ISIS in order to extract spectra has prompted the writing of routines which will do the basic hack-work with a minimal amount of interaction from the user. Although they were written with spectral data in mind, there are no ``spectrum-specific'' features in the software which means they can be applied to any CCD data.
Exploring Chaos: A Case Study.
ERIC Educational Resources Information Center
Nemirovsky, Ricardo; Tinker, Robert
1993-01-01
Describes software, hardware, and devices that were designed to provide students with an environment to experiment with basic ideas of mechanics, including nonlinear dynamics. Examines the behavior of a Lorenzian water wheel by comparing experimental data with theoretical results obtained from computer-based sensors. (MDH)
78 FR 54731 - Update to the List of Basic Medical Supplies
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-05
... Suture removal kits Syringes Thermometers, mercury for measuring human body temperature Tongue depressors... equipment Orthopedic traction devices and tables Human body positioners including pads, wedges, cradles... staples; and removal kits Tourniquets Thermometers for measuring human body temperature Clinical basins...
23 CFR 655.604 - Achieving basic uniformity.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS TRAFFIC OPERATIONS Traffic Control Devices on Federal-Aid and Other Streets and Highways § 655.604... the Highway Safety Program Guideline 21, “Roadway Safety.” Highway planning and research funds and...
23 CFR 655.604 - Achieving basic uniformity.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS TRAFFIC OPERATIONS Traffic Control Devices on Federal-Aid and Other Streets and Highways § 655.604... the Highway Safety Program Guideline 21, “Roadway Safety.” Highway planning and research funds and...
Code of Federal Regulations, 2012 CFR
2012-10-01
... devices, and other basic medical and rescue equipment and their primary function will be rescue activities. ... non-Federal governing body) to provide fire suppression services within a fixed geographical area. A... precluded from submitting an additional application. Non-Federal airport and/or port authority fire...
Electromechanical resistive switching via back-to-back Schottky junctions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Lijie, E-mail: L.Li@swansea.ac.uk
The physics of the electromechanical resistive switching is uncovered using the theory of back-to-back Schottky junctions combined with the quantum domain space charge transport. A theoretical model of the basic element of resistive switching devices realized by the metal-ZnO nanowires-metal structure has been created and analyzed. Simulation results show that the reverse biased Schottky junction and the air gap impedance dominate the current-voltage relation at higher external voltages; thereby electromechanically varying the air gap thickness causes the device exhibit resistive tuning characteristics. As the device dimension is in nanometre scale, investigation of the model based on quantum mechanics has alsomore » been conducted.« less
A self-resetting spiking phase-change neuron
NASA Astrophysics Data System (ADS)
Cobley, R. A.; Hayat, H.; Wright, C. D.
2018-05-01
Neuromorphic, or brain-inspired, computing applications of phase-change devices have to date concentrated primarily on the implementation of phase-change synapses. However, the so-called accumulation mode of operation inherent in phase-change materials and devices can also be used to mimic the integrative properties of a biological neuron. Here we demonstrate, using physical modelling of nanoscale devices and SPICE modelling of associated circuits, that a single phase-change memory cell integrated into a comparator type circuit can deliver a basic hardware mimic of an integrate-and-fire spiking neuron with self-resetting capabilities. Such phase-change neurons, in combination with phase-change synapses, can potentially open a new route for the realisation of all-phase-change neuromorphic computing.
[Development of a massage device based on microcontroller in the field of alimentary tract].
Huang, Rong; Peng, Chenglin; He, Hongmei; Zhu, Jing
2007-12-01
In this artical is first reported a survey of the progress in research of MEMS technology. Then, the basic structure, features and the principles of a massage device based on microcontroller in the field of alimentary tract are introduced. Special emphasis is laid on the utilization of MSP430F123 microprocessor for producing a kind of period pulse to control the power of massage capsule. In general, the research and development of the massage device in the field of alimentary tract have active support and deep significance to therapy in the clinical and business settings as well as in the development of biomedical engineering and MEMS.
NASA Astrophysics Data System (ADS)
Králik, Juraj
2017-07-01
The paper presents the probabilistic and sensitivity analysis of the efficiency of the damping devices cover of nuclear power plant under impact of the container of nuclear fuel of type TK C30 drop. The finite element idealization of nuclear power plant structure is used in space. The steel pipe damper system is proposed for dissipation of the kinetic energy of the container free fall. The experimental results of the shock-damper basic element behavior under impact loads are presented. The Newmark integration method is used for solution of the dynamic equations. The sensitivity and probabilistic analysis of damping devices was realized in the AntHILL and ANSYS software.
Review on Variable Emissivity Materials and Devices Based on Smart Chromism
NASA Astrophysics Data System (ADS)
Lang, FengPei; Wang, Hao; Zhang, ShengJun; Liu, JingBing; Yan, Hui
2018-01-01
Variable emissivity material (VEM) can dynamically vary its emissivity and infrared radiation under certain conditions, which may find potential applications in infrared stealth/camouflage, solar thermal collector, spacecraft thermal control, and smart energy-saving windows. In this paper, the variable emissivity materials and devices based on electrochromism and thermochromism are introduced. The basic principle and present status of the research in these fields are overviewed. Four kinds of representative VEMs are extensively summarized, which are tungsten trioxides (WO3), conducting polymers (CPs), perovskite oxides (A_{1-{x}}B_{{x}}MO3), and vanadium dioxide (VO2). Finally, specific issues confronted with electrochromic and thermochromic materials and devices are prospected.
Stimulus factors in motion perception and spatial orientation
NASA Technical Reports Server (NTRS)
Post, R. B.; Johnson, C. A.
1984-01-01
The Malcolm horizon utilizes a large projected light stimulus Peripheral Vision Horizon Device (PVHD) as an attitude indicator in order to achieve a more compelling sense of roll than is obtained with smaller devices. The basic principle is that the larger stimulus is more similar to visibility of a real horizon during roll, and does not require fixation and attention to the degree that smaller displays do. Successful implementation of such a device requires adjustment of the parameters of the visual stimulus so that its effects on motion perception and spatial orientation are optimized. With this purpose in mind, the effects of relevant image variables on the perception of object motion, self motion and spatial orientation are reviewed.
A self-resetting spiking phase-change neuron.
Cobley, R A; Hayat, H; Wright, C D
2018-05-11
Neuromorphic, or brain-inspired, computing applications of phase-change devices have to date concentrated primarily on the implementation of phase-change synapses. However, the so-called accumulation mode of operation inherent in phase-change materials and devices can also be used to mimic the integrative properties of a biological neuron. Here we demonstrate, using physical modelling of nanoscale devices and SPICE modelling of associated circuits, that a single phase-change memory cell integrated into a comparator type circuit can deliver a basic hardware mimic of an integrate-and-fire spiking neuron with self-resetting capabilities. Such phase-change neurons, in combination with phase-change synapses, can potentially open a new route for the realisation of all-phase-change neuromorphic computing.
Chinbe, Hiroyuki; Yoneyama, Takeshi; Watanabe, Tetsuyou; Miyashita, Katsuyoshi; Nakada, Mitsutoshi
2018-01-01
Development and evaluation of an effective attachment device for a bilateral brain tumor resection robotic surgery system based on the sensory performance of the human index finger in order to precisely detect gripping- and pulling-force feedback. First, a basic test was conducted to investigate the performance of the human index finger in the gripping- and pulling-force feedback system. Based on the test result, a new finger-attachment device was designed and constructed. Then, discrimination tests were conducted to assess the pulling force and the feedback on the hardness of the gripped material. The results of the basic test show the application of pulling force on the side surface of the finger has an advantage to distinguish the pulling force when the gripping force is applied on the finger-touching surface. Based on this result, a finger-attachment device that applies a gripping force on the finger surface and pulling force on the side surface of the finger was developed. By conducting a discrimination test to assess the hardness of the gripped material, an operator can distinguish whether the gripped material is harder or softer than a normal brain tissue. This will help in confirming whether the gripped material is a tumor. By conducting a discrimination test to assess the pulling force, an operator can distinguish the pulling-force resistance when attempting to pull off the soft material. Pulling-force feedback may help avoid the breaking of blood pipes when they are trapped in the gripper or attached to the gripped tissue. The finger-attachment device that was developed for detecting gripping- and pulling-force feedback may play an important role in the development of future neurosurgery robotic systems for precise and safe resection of brain tumors.
Development of a one-dimensional Position Sensitive Detector for tracking applications
NASA Astrophysics Data System (ADS)
Lydecker, Leigh Kent, IV
Optical Position Sensitive Detectors (PSDs) are a non-contact method of tracking the location of a light spot. Silicon-based versions of such sensors are fabricated with standard CMOS processing, are inexpensive and provide a real-time, analog signal output corresponding to the position of the light spot. Because they are non-contact, they do not degrade over time from surface friction due to repetitive sliding motion associated with standard full contact sliding potentiometers. This results in long, reliable device lifetimes. In this work, an innovative PSD was developed to replace the linear hard contact potentiometer currently being used in a human-computer interface architecture. First, a basic lateral effect PSD was developed to provide real-time positioning of the mouthpiece used in the interface architecture which tracks along a single axis. During the course of this work, multiple device geometries were fabricated and analyzed resulting in a down selection of a final design. This final device design was then characterized in terms of resolution and responsivity and produced in larger quantities as initial prototypes for the test product integration. Finally, an electronic readout circuit was developed in order to interface the dual- line lateral effect PSD developed in this thesis with specifications required for product integration. To simplify position sensing, an innovative type of optical position sensor was developed using a linear photodiodes with back-to-back connections. This so- called Self-Balancing Position Sensitive Detector (SBPSD) requires significantly fewer processing steps than the basic lateral effect position sensitive detector discussed above and eliminates the need for external readout circuitry entirely. Prototype devices were fabricated in this work, and the performance characteristics of these devices were established paving the way for ultimate integration into the target product as well as additional applications.
Huang, Chuixiu; Eibak, Lars Erik Eng; Gjelstad, Astrid; Shen, Xiantao; Trones, Roger; Jensen, Henrik; Pedersen-Bjergaard, Stig
2014-01-24
In this work, a single-well electromembrane extraction (EME) device was developed based on a thin (100μm) and flat porous membrane of polypropylene supporting a liquid membrane. The new EME device was operated with a relatively large acceptor solution volume to promote a high recovery. Using this EME device, exhaustive extraction of the basic drugs quetiapine, citalopram, amitriptyline, methadone and sertraline was investigated from both acidified water samples and human plasma. The volume of acceptor solution, extraction time, and extraction voltage were found to be important factors for obtaining exhaustive extraction. 2-Nitrophenyl octyl ether was selected as the optimal organic solvent for the supported liquid membrane. From spiked acidified water samples (600μl), EME was carried out with 600μl of 20mM HCOOH as acceptor solution for 15min and with an extraction voltage of 250V. Under these conditions, extraction recoveries were in the range 89-112%. From human plasma samples (600μl), EME was carried out with 600μl of 20mM HCOOH as acceptor solution for 30min and with an extraction voltage of 300V. Under these conditions, extraction recoveries were in the range of 83-105%. When combined with LC-MS, the new EME device provided linearity in the range 10-1000ng/ml for all analytes (R(2)>0.990). The repeatability at low (10ng/ml), medium (100ng/ml), and high (1000ng/ml) concentration level for all five analytes were less than 10% (RSD). The limits of quantification (S/N=10) were found to be in the range 0.7-6.4ng/ml. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Snider, Gregory
2000-03-01
Quantum-dot Cellular Automata (QCA) [1] is a promising architecture which employs quantum dots for digital computation. It is a revolutionary approach that holds the promise of high device density and low power dissipation. A basic QCA cell consists of four quantum dots coupled capacitively and by tunnel barriers. The cell is biased to contain two excess electrons within the four dots, which are forced to opposite "corners" of the four-dot cell by mutual Coulomb repulsion. These two possible polarization states of the cell will represent logic "0" and "1". Properly arranged, arrays of these basic cells can implement Boolean logic functions. Experimental results from functional QCA devices built of nanoscale metal dots defined by tunnel barriers will be presented. The experimental devices to be presented consist of Al islands, which we will call quantum dots, interconnected by tunnel junctions and lithographically defined capacitors. Aluminum/ aluminum-oxide/aluminum tunnel junctions were fabricated using a standard e-beam lithography and shadow evaporation technique. The experiments were performed in a dilution refrigerator at a temperature of 70 mK. The operation of a cell is evaluated by direct measurements of the charge state of dots within a cell as the input voltage is changed. The experimental demonstration of a functioning cell will be presented. A line of three cells demonstrates that there are no metastable switching states in a line of cells. A QCA majority gate will also be presented, which is a programmable AND/OR gate and represents the basic building block of QCA systems. The results of recent experiments will be presented. 1. C.S. Lent, P.D. Tougaw, W. Porod, and G.H. Bernstein, Nanotechnology, 4, 49 (1993).
Quantum state transfer in double-quantum-well devices
NASA Technical Reports Server (NTRS)
Jakumeit, Jurgen; Tutt, Marcel; Pavlidis, Dimitris
1994-01-01
A Monte Carlo simulation of double-quantum-well (DQW) devices is presented in view of analyzing the quantum state transfer (QST) effect. Different structures, based on the AlGaAs/GaAs system, were simulated at 77 and 300 K and optimized in terms of electron transfer and device speed. The analysis revealed the dominant role of the impurity scattering for the QST. Different approaches were used for the optimization of QST devices and basic physical limitations were found in the electron transfer between the QWs. The maximum transfer of electrons from a high to a low mobility well was at best 20%. Negative differential resistance is hampered by the almost linear rather than threshold dependent relation of electron transfer on electric field. By optimizing the doping profile the operation frequency limit could be extended to 260 GHz.
fMRI-Compatible Electromagnetic Haptic Interface.
Riener, R; Villgrattner, T; Kleiser, R; Nef, T; Kollias, S
2005-01-01
A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.
The Importance of Motivation in the Typewriting Classroom
ERIC Educational Resources Information Center
Jacks, Mary L.
1976-01-01
If a typing teacher makes maximum use of intrinsic rewards, it will not be necessary to use many extrinsic motivational devices. The implications of Maslow's "hierarchy of needs" for teachers of adolescents, and the basic motivational principles developed by Rowe are presented. (Author/AJ)
Synthesizing a novel genetic sequential logic circuit: a push-on push-off switch
Lou, Chunbo; Liu, Xili; Ni, Ming; Huang, Yiqi; Huang, Qiushi; Huang, Longwen; Jiang, Lingli; Lu, Dan; Wang, Mingcong; Liu, Chang; Chen, Daizhuo; Chen, Chongyi; Chen, Xiaoyue; Yang, Le; Ma, Haisu; Chen, Jianguo; Ouyang, Qi
2010-01-01
Design and synthesis of basic functional circuits are the fundamental tasks of synthetic biologists. Before it is possible to engineer higher-order genetic networks that can perform complex functions, a toolkit of basic devices must be developed. Among those devices, sequential logic circuits are expected to be the foundation of the genetic information-processing systems. In this study, we report the design and construction of a genetic sequential logic circuit in Escherichia coli. It can generate different outputs in response to the same input signal on the basis of its internal state, and ‘memorize' the output. The circuit is composed of two parts: (1) a bistable switch memory module and (2) a double-repressed promoter NOR gate module. The two modules were individually rationally designed, and they were coupled together by fine-tuning the interconnecting parts through directed evolution. After fine-tuning, the circuit could be repeatedly, alternatively triggered by the same input signal; it functions as a push-on push-off switch. PMID:20212522
Synthesizing a novel genetic sequential logic circuit: a push-on push-off switch.
Lou, Chunbo; Liu, Xili; Ni, Ming; Huang, Yiqi; Huang, Qiushi; Huang, Longwen; Jiang, Lingli; Lu, Dan; Wang, Mingcong; Liu, Chang; Chen, Daizhuo; Chen, Chongyi; Chen, Xiaoyue; Yang, Le; Ma, Haisu; Chen, Jianguo; Ouyang, Qi
2010-01-01
Design and synthesis of basic functional circuits are the fundamental tasks of synthetic biologists. Before it is possible to engineer higher-order genetic networks that can perform complex functions, a toolkit of basic devices must be developed. Among those devices, sequential logic circuits are expected to be the foundation of the genetic information-processing systems. In this study, we report the design and construction of a genetic sequential logic circuit in Escherichia coli. It can generate different outputs in response to the same input signal on the basis of its internal state, and 'memorize' the output. The circuit is composed of two parts: (1) a bistable switch memory module and (2) a double-repressed promoter NOR gate module. The two modules were individually rationally designed, and they were coupled together by fine-tuning the interconnecting parts through directed evolution. After fine-tuning, the circuit could be repeatedly, alternatively triggered by the same input signal; it functions as a push-on push-off switch.
Nanotechnology and bone healing.
Harvey, Edward J; Henderson, Janet E; Vengallatore, Srikar T
2010-03-01
Nanotechnology and its attendant techniques have yet to make a significant impact on the science of bone healing. However, the potential benefits are immediately obvious with the result that hundreds of researchers and firms are performing the basic research needed to mature this nascent, yet soon to be fruitful niche. Together with genomics and proteomics, and combined with tissue engineering, this is the new face of orthopaedic technology. The concepts that orthopaedic surgeons recognize are fabrication processes that have resulted in porous implant substrates as bone defect augmentation and medication-carrier devices. However, there are dozens of applications in orthopaedic traumatology and bone healing for nanometer-sized entities, structures, surfaces, and devices with characteristic lengths ranging from 10s of nanometers to a few micrometers. Examples include scaffolds, delivery mechanisms, controlled modification of surface topography and composition, and biomicroelectromechanical systems. We review the basic science, clinical implications, and early applications of the nanotechnology revolution and emphasize the rich possibilities that exist at the crossover region between micro- and nanotechnology for developing new treatments for bone healing.
Semiconductor Characterization: from Growth to Manufacturing
NASA Astrophysics Data System (ADS)
Colombo, Luigi
The successful growth and/or deposition of materials for any application require basic understanding of the materials physics for a given device. At the beginning, the first and most obvious characterization tool is visual observation; this is particularly true for single crystal growth. The characterization tools are usually prioritized in order of ease of measurement, and have become especially sophisticated as we have moved from the characterization of macroscopic crystals and films to atomically thin materials and nanostructures. While a lot attention is devoted to characterization and understanding of materials physics at the nano level, the characterization of single crystals as substrates or active components is still critically important. In this presentation, I will review and discuss the basic materials characterization techniques used to get to the materials physics to bring crystals and thin films from research to manufacturing in the fields of infrared detection, non-volatile memories, and transistors. Finally I will present and discuss metrology techniques used to understand the physics and chemistry of atomically thin two-dimensional materials for future device applications.
A Simple Memristor Model for Circuit Simulations
NASA Astrophysics Data System (ADS)
Fullerton, Farrah-Amoy; Joe, Aaleyah; Gergel-Hackett, Nadine; Department of Chemistry; Physics Team
This work describes the development of a model for the memristor, a novel nanoelectronic technology. The model was designed to replicate the real-world electrical characteristics of previously fabricated memristor devices, but was constructed with basic circuit elements using a free widely available circuit simulator, LT Spice. The modeled memrsistors were then used to construct a circuit that performs material implication. Material implication is a digital logic that can be used to perform all of the same basic functions as traditional CMOS gates, but with fewer nanoelectronic devices. This memristor-based digital logic could enable memristors' use in new paradigms of computer architecture with advantages in size, speed, and power over traditional computing circuits. Additionally, the ability to model the real-world electrical characteristics of memristors in a free circuit simulator using its standard library of elements could enable not only the development of memristor material implication, but also the development of a virtually unlimited array of other memristor-based circuits.
Doped organic transistors operating in the inversion and depletion regime
Lüssem, Björn; Tietze, Max L.; Kleemann, Hans; Hoßbach, Christoph; Bartha, Johann W.; Zakhidov, Alexander; Leo, Karl
2013-01-01
The inversion field-effect transistor is the basic device of modern microelectronics and is nowadays used more than a billion times on every state-of-the-art computer chip. In the future, this rigid technology will be complemented by flexible electronics produced at extremely low cost. Organic field-effect transistors have the potential to be the basic device for flexible electronics, but still need much improvement. In particular, despite more than 20 years of research, organic inversion mode transistors have not been reported so far. Here we discuss the first realization of organic inversion transistors and the optimization of organic depletion transistors by our organic doping technology. We show that the transistor parameters—in particular, the threshold voltage and the ON/OFF ratio—can be controlled by the doping concentration and the thickness of the transistor channel. Injection of minority carriers into the doped transistor channel is achieved by doped contacts, which allows forming an inversion layer. PMID:24225722
Getting started with Open-Hardware: Development and Control of Microfluidic Devices
da Costa, Eric Tavares; Mora, Maria F.; Willis, Peter A.; do Lago, Claudimir L.; Jiao, Hong; Garcia, Carlos D.
2014-01-01
Understanding basic concepts of electronics and computer programming allows researchers to get the most out of the equipment found in their laboratories. Although a number of platforms have been specifically designed for the general public and are supported by a vast array of on-line tutorials, this subject is not normally included in university chemistry curricula. Aiming to provide the basic concepts of hardware and software, this article is focused on the design and use of a simple module to control a series of PDMS-based valves. The module is based on a low-cost microprocessor (Teensy) and open-source software (Arduino). The microvalves were fabricated using thin sheets of PDMS and patterned using CO2 laser engraving, providing a simple and efficient way to fabricate devices without the traditional photolithographic process or facilities. Synchronization of valve control enabled the development of two simple devices to perform injection (1.6 ± 0.4 μL/stroke) and mixing of different solutions. Furthermore, a practical demonstration of the utility of this system for microscale chemical sample handling and analysis was achieved performing an on-chip acid-base titration, followed by conductivity detection with an open-source low-cost detection system. Overall, the system provided a very reproducible (98%) platform to perform fluid delivery at the microfluidic scale. PMID:24823494
Current trends in hardware and software for brain-computer interfaces (BCIs)
NASA Astrophysics Data System (ADS)
Brunner, P.; Bianchi, L.; Guger, C.; Cincotti, F.; Schalk, G.
2011-04-01
A brain-computer interface (BCI) provides a non-muscular communication channel to people with and without disabilities. BCI devices consist of hardware and software. BCI hardware records signals from the brain, either invasively or non-invasively, using a series of device components. BCI software then translates these signals into device output commands and provides feedback. One may categorize different types of BCI applications into the following four categories: basic research, clinical/translational research, consumer products, and emerging applications. These four categories use BCI hardware and software, but have different sets of requirements. For example, while basic research needs to explore a wide range of system configurations, and thus requires a wide range of hardware and software capabilities, applications in the other three categories may be designed for relatively narrow purposes and thus may only need a very limited subset of capabilities. This paper summarizes technical aspects for each of these four categories of BCI applications. The results indicate that BCI technology is in transition from isolated demonstrations to systematic research and commercial development. This process requires several multidisciplinary efforts, including the development of better integrated and more robust BCI hardware and software, the definition of standardized interfaces, and the development of certification, dissemination and reimbursement procedures.
Tutorial: Physics and modeling of Hall thrusters
NASA Astrophysics Data System (ADS)
Boeuf, Jean-Pierre
2017-01-01
Hall thrusters are very efficient and competitive electric propulsion devices for satellites and are currently in use in a number of telecommunications and government spacecraft. Their power spans from 100 W to 20 kW, with thrust between a few mN and 1 N and specific impulse values between 1000 and 3000 s. The basic idea of Hall thrusters consists in generating a large local electric field in a plasma by using a transverse magnetic field to reduce the electron conductivity. This electric field can extract positive ions from the plasma and accelerate them to high velocity without extracting grids, providing the thrust. These principles are simple in appearance but the physics of Hall thrusters is very intricate and non-linear because of the complex electron transport across the magnetic field and its coupling with the electric field and the neutral atom density. This paper describes the basic physics of Hall thrusters and gives a (non-exhaustive) summary of the research efforts that have been devoted to the modelling and understanding of these devices in the last 20 years. Although the predictive capabilities of the models are still not sufficient for a full computer aided design of Hall thrusters, significant progress has been made in the qualitative and quantitative understanding of these devices.
Consumer sleep tracking devices: a critical review.
Lee, Jeon; Finkelstein, Joseph
2015-01-01
Consumer sleep tracking devices are widely advertised as effective means to monitor and manage sleep quality and to provide positive effects on overall heath. However objective evidence supporting these claims is not always readily available. The goal of this study was to perform a comprehensive review of available information on six representative sleep tracking devices: BodyMedia FIT, Fitbit Flex, Jawbone UP, Basis Band, Innovative Sleep Solutions SleepTracker, and Zeo Sleep Manager Pro. The review was conducted along the following dimensions: output metrics, theoretical frameworks, systematic evaluation, and FDA clearance. The review identified a critical lack of basic information about the devices: five out of six devices provided no supporting information on their sensor accuracy and four out of six devices provided no information on their output metrics accuracy. Only three devices were found to have related peer-reviewed articles. However in these articles wake detection accuracy was revealed to be quite low and to vary widely (BodyMedia, 49.9±3.6%; Fitbit, 19.8%; Zeo, 78.9% to 83.5%). No supporting evidence on how well tracking devices can help mitigate sleep loss and manage sleep disturbances in practical life was provided.
NASA Astrophysics Data System (ADS)
Yuan, Ying; Peng, Sha; Long, Huabao; Liu, Runhan; Wei, Dong; Zhang, Xinyu; Wang, Haiwei; Xie, Changsheng
2018-02-01
In this paper, we propose a new device composed of patterned sub-wavelength arrays to investigate surface plasmons (SPs) over sub-wavelength metal nano-structures. The device consists of silicon substrate and sub-wavelength patterns fabricated on a layer of aluminum film with nanometer thickness. Each sub-wavelength pattern formed in aluminum film is composed of a basic nano-square and twelve triangles for shaping single nano-pattern, which are uniformly distributed on the four sides of each square. Reflectance spectra and electric field distribution in infrared region are simulated. Numerical simulation results demonstrate that the device can efficiently lower its reflectance in infrared spectrum, and the response frequency can be controlled by only changing the device parameters such as square side length and then triangle vertex angle. Besides, the simulated electric field distribution of the device shows obviously field localization effect at the edges of aluminum film nano-structure. The electric filed around the tips of aluminum triangles is localized into sub-wavelength scale, so as to be beyond the common diffraction limitation. Our work will help to reveal the interesting properties of SPs device, and also bring new prospect of photonic device.
Contamination avoidance devices for poppet type shutoff valves
NASA Technical Reports Server (NTRS)
Endicott, D. L.
1972-01-01
The technology required to provide acceptable contamination damage avoidance characteristics for poppet type shutoff valves is discussed. Evaluation of the contamination avoidance characteristics of the basic 1T32095 propellant shutoff valve, the cycle life performance of these valves in an uncontaminated environment, and the effectiveness of various auxiliary contamination avoidance devices when used in conjunction with these poppet type valves are included. In addition, a secondary objective is to evaluate two methods of monitoring the performance of the test valves during actual operations using acoustical monitoring instrumentation.
Hayes Lane, Susan; Serafica, Reimund; Huffman, Carolyn; Cuddy, Alyssa
2016-01-01
In the current healthcare environment, nurses must have a basic understanding of research to lead change and implement evidence-based practice. The purpose of this study was to evaluate the effectiveness of an educational intervention formulated on the framework of the Great American Cookie Experiment measuring nurses' research knowledge, attitudes, and practice using mobile device gaming. This multisite quantitative study provides insight into promotion of research and information about best practices on innovative teaching strategies for nurses.
A comment on the dependence of LED’s efficiency on the junction ideality factor
NASA Astrophysics Data System (ADS)
Sethi, Anubhav; Gupta, Yashika; Arun, P.
2018-05-01
P–n junctions form the basic building blocks for any semiconductor device. Therefore, the complete understanding of the junction characteristics is very important. Although being a widely discussed topic in electronics, there are still some gaps such as finding the value and significance of the junction ideality factor, that needs to be addressed. In this article we have discussed the problems faced while extracting the ideality factor from the I–V characteristics of a p–n LED and its significance in device performance.
Conductive nanomaterials for printed electronics.
Kamyshny, Alexander; Magdassi, Shlomo
2014-09-10
This is a review on recent developments in the field of conductive nanomaterials and their application in printed electronics, with particular emphasis on inkjet printing of ink formulations based on metal nanoparticles, carbon nanotubes, and graphene sheets. The review describes the basic properties of conductive nanomaterials suitable for printed electronics (metal nanoparticles, carbon nanotubes, and graphene), their stabilization in dispersions, formulations of conductive inks, and obtaining conductive patterns by using various sintering methods. Applications of conductive nanomaterials for electronic devices (transparent electrodes, metallization of solar cells, RFID antennas, TFTs, and light emitting devices) are also briefly reviewed.
NASA Astrophysics Data System (ADS)
Kanaki, Toshiki; Koyama, Tomohiro; Chiba, Daichi; Ohya, Shinobu; Tanaka, Masaaki
2016-10-01
We propose a current-in-plane spin-valve field-effect transistor (CIP-SV-FET), which is composed of a ferromagnet/nonferromagnet/ferromagnet trilayer structure and a gate electrode. This is a promising device alternative to spin metal-oxide-semiconductor field-effect transistors. Here, we fabricate a ferromagnetic-semiconductor GaMnAs-based CIP-SV-FET and demonstrate its basic operation of the resistance modulation both by the magnetization configuration and by the gate electric field. Furthermore, we present the electric-field-assisted magnetization reversal in this device.
NASA Technical Reports Server (NTRS)
Coakley, Peter G. (Editor)
1988-01-01
The effects of nuclear and space radiation on the performance of electronic devices are discussed in reviews and reports of recent investigations. Topics addressed include the basic mechanisms of radiation effects, dosimetry and energy-dependent effects, sensors in and for radiation environments, EMP/SGEMP/IEMP phenomena, radiation effects on isolation technologies, and spacecraft charging and space radiation effects. Consideration is given to device radiation effects and hardening, hardness assurance and testing techniques, IC radiation effects and hardening, and single-event phenomena.
Chen, Xiaodong; Ren, Liqiang; Zheng, Bin; Liu, Hong
2013-01-01
The conventional optical microscopes have been used widely in scientific research and in clinical practice. The modern digital microscopic devices combine the power of optical imaging and computerized analysis, archiving and communication techniques. It has a great potential in pathological examinations for improving the efficiency and accuracy of clinical diagnosis. This chapter reviews the basic optical principles of conventional microscopes, fluorescence microscopes and electron microscopes. The recent developments and future clinical applications of advanced digital microscopic imaging methods and computer assisted diagnosis schemes are also discussed.
Spin manipulation with magnetic semiconductor barriers.
Miao, Guo-Xing; Moodera, Jagadeesh S
2015-01-14
Magnetic semiconductors are a class of materials with special spin-filtering capabilities with magnetically tunable energy gaps. Many of these materials also possess another intrinsic property: indirect exchange interaction between the localized magnetic moments and the adjacent free electrons, which manifests as an extremely large effective magnetic field applying only on the spin degrees of freedom of the free electrons. Novel device concepts can be created by taking advantage of these properties. We discuss in the article the basic principles of these phenomena, and potential ways of applying them in constructing spintronic devices.
Technology platforms for remote monitoring of vital signs in the new era of telemedicine.
Zhao, Fang; Li, Meng; Tsien, Joe Z
2015-07-01
Driven by healthcare cost and home healthcare need, the development of remote monitoring technologies is poised to improve and revolutionize healthcare delivery and accessibility. This paper reviews the recent progress in the field of remote monitoring technologies that may have the potential to become the basic platforms for telemedicine. In particular, key techniques and devices for monitoring cardiorespiratory activity, blood pressure and blood glucose concentration are summarized and discussed. In addition, the US FDA approved remote vital signs monitoring devices currently available on the market are presented.
Neely, Alice N.; Sittig, Dean F.
2002-01-01
Computer technology from the management of individual patient medical records to the tracking of epidemiologic trends has become an essential part of all aspects of modern medicine. Consequently, computers, including bedside components, point-of-care testing equipment, and handheld computer devices, are increasingly present in patients’ rooms. Recent articles have indicated that computer hardware, just as other medical equipment, may act as a reservoir for microorganisms and contribute to the transfer of pathogens to patients. This article presents basic microbiological concepts relative to infection, reviews the present literature concerning possible links between computer contamination and nosocomial colonizations and infections, discusses basic principles for the control of contamination, and provides guidelines for reducing the risk of transfer of microorganisms to susceptible patient populations. PMID:12223502
10 CFR 431.62 - Definitions concerning commercial refrigerators, freezers and refrigerator-freezers.
Code of Federal Regulations, 2011 CFR
2011-01-01
...-section. Basic model means, with respect to commercial refrigerators, freezers, and refrigerator-freezers... 430); (2) Is not designed and marketed exclusively for medical, scientific, or research purposes; (3... standard product temperature-measuring device. Vertical Closed means equipment with hinged or sliding doors...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-31
..., and the facilities and controls used for, the manufacture, preproduction design validation (including... part 820 (21 CFR part 820) and sets forth basic CGMP requirements governing the design, manufacture... manufacturers for compliance with QS requirements encompassing design, production, installation, and servicing...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-24
... the facilities and controls used for, the manufacture, pre-production design validation (including a... 820 (21 CFR part 820) and sets forth basic CGMP requirements governing the design, manufacture... manufacturers for compliance with QS requirements encompassing design, production, installation, and servicing...
Code of Federal Regulations, 2014 CFR
2014-04-01
... used in, and the facilities and controls used for, the design, manufacture, packaging, labeling... compliance with the Federal Food, Drug, and Cosmetic Act (the act). This part establishes basic requirements... controls apply only to those devices listed in § 820.30(a)(2). This regulation does not apply to...
Code of Federal Regulations, 2012 CFR
2012-04-01
... used in, and the facilities and controls used for, the design, manufacture, packaging, labeling... compliance with the Federal Food, Drug, and Cosmetic Act (the act). This part establishes basic requirements... controls apply only to those devices listed in § 820.30(a)(2). This regulation does not apply to...
Code of Federal Regulations, 2011 CFR
2011-04-01
... used in, and the facilities and controls used for, the design, manufacture, packaging, labeling... compliance with the Federal Food, Drug, and Cosmetic Act (the act). This part establishes basic requirements... controls apply only to those devices listed in § 820.30(a)(2). This regulation does not apply to...
Code of Federal Regulations, 2013 CFR
2013-04-01
... used in, and the facilities and controls used for, the design, manufacture, packaging, labeling... compliance with the Federal Food, Drug, and Cosmetic Act (the act). This part establishes basic requirements... controls apply only to those devices listed in § 820.30(a)(2). This regulation does not apply to...
CCDs in the Mechanics Lab--A Competitive Alternative? (Part I).
ERIC Educational Resources Information Center
Pinto, Fabrizio
1995-01-01
Reports on the implementation of a relatively low-cost, versatile, and intuitive system to teach basic mechanics based on the use of a Charge-Coupled Device (CCD) camera and inexpensive image-processing and analysis software. Discusses strengths and limitations of CCD imaging technologies. (JRH)
ERIC Educational Resources Information Center
Navarro, Aaron B.
1981-01-01
Presents a program in Level II BASIC for a TRS-80 computer that simulates a Turing machine and discusses the nature of the device. The program is run interactively and is designed to be used as an educational tool by computer science or mathematics students studying computational or automata theory. (MP)
On Directionality of Phrase Structure Building
ERIC Educational Resources Information Center
Chesi, Cristiano
2015-01-01
Minimalism in grammatical theorizing (Chomsky in "The minimalist program." MIT Press, Cambridge, 1995) led to simpler linguistic devices and a better focalization of the core properties of the structure building engine: a lexicon and a free (recursive) phrase formation operation, dubbed Merge, are the basic components that serve in…
Improved perceptual-motor performance measurement system
NASA Technical Reports Server (NTRS)
Parker, J. F., Jr.; Reilly, R. E.
1969-01-01
Battery of tests determines the primary dimensions of perceptual-motor performance. Eighteen basic measures range from simple tests to sophisticated electronic devices. Improved system has one unit for the subject containing test display and response elements, and one for the experimenter where test setups, programming, and scoring are accomplished.
Electronic device for endosurgical skills training (EDEST): study of reliability.
Pagador, J B; Uson, J; Sánchez, M A; Moyano, J L; Moreno, J; Bustos, P; Mateos, J; Sánchez-Margallo, F M
2011-05-01
Minimally Invasive Surgery procedures are commonly used in many surgical practices, but surgeons need specific training models and devices due to its difficulty and complexity. In this paper, an innovative electronic device for endosurgical skills training (EDEST) is presented. A study on reliability for this device was performed. Different electronic components were used to compose this new training device. The EDEST was focused on two basic laparoscopic tasks: triangulation and coordination manoeuvres. A configuration and statistical software was developed to complement the functionality of the device. A calibration method was used to assure the proper work of the device. A total of 35 subjects (8 experts and 27 novices) were used to check the reliability of the system using the MTBF analysis. Configuration values for triangulation and coordination exercises were calculated as 0.5 s limit threshold and 800-11,000 lux range of light intensity, respectively. Zero errors in 1,050 executions (0%) for triangulation and 21 errors in 5,670 executions (0.37%) for coordination were obtained. A MTBF of 2.97 h was obtained. The results show that the reliability of the EDEST device is acceptable when used under previously defined light conditions. These results along with previous work could demonstrate that the EDEST device can help surgeons during first training stages.
The cost of assistive devices for children with mobility limitation.
Korpela, R A; Siirtola, T O; Koivikko, M J
1992-10-01
This study evaluated the costs of assistive devices for children with motor limitations at home, in day care, and in school, and the effect of diagnosis and severity of disabilities on costs. 201 children (mean age 7.4 years) who used 1274 various assistive devices (85.7% at home, 6.1% in day care, and 8.2% in school) were studied. The cost per device varied from $8.14 to $8138 with an average value of $539 per device. The distribution of costs per capita was unequal: 52.2% of children used 15.6% of total costs and 4.5% of children used 20.8% of total costs. The severity of motor impairment and the age of the child were the most important indicators associated with the need and cost of assistive devices. Assistive devices for basic needs, such as sitting, mobility, and personal hygiene, had a relatively low effect on costs in comparison with the high-technology devices, like powered wheelchairs and computers. Better cooperation with day care and school professionals, better assessment of needs, follow-up and recirculation of assistive devices are ways to promote rehabilitation services and partly solve the discrepancies between the costs of available technology and the resources to pay for it.
Swell Sleeves for Testing Explosive Devices
NASA Technical Reports Server (NTRS)
Hinkel, Todd J.; Dean, Richard J.; Hohmann, Carl W.; Hacker, Scott C.; Harrington, Douglas W.; Bacak, James W.
2003-01-01
A method of testing explosive and pyrotechnic devices involves exploding the devices inside swell sleeves. Swell sleeves have been used previously for measuring forces. In the present method, they are used to obtain quantitative indications of the energy released in explosions of the devices under test. A swell sleeve is basically a thick-walled, hollow metal cylinder threaded at one end to accept a threaded surface on a device to be tested (see Figure 1). Once the device has been tightly threaded in place in the swell sleeve, the device-and-swell-sleeve assembly is placed in a test fixture, then the device is detonated. After the explosion, the assembly is removed from the test fixture and placed in a coordinate-measuring machine for measurement of the diameter of the swell sleeve as a function of axial position. For each axial position, the original diameter of the sleeve is subtracted from the diameter of the sleeve as swollen by the explosion to obtain the diametral swelling as a function of axial position (see Figure 2). The amount of swelling is taken as a measure of the energy released in the explosion. The amount of swelling can be compared to a standard amount of swelling to determine whether the pyrotechnic device functioned as specified.
Low-cost, portable open-source gas monitoring device based on chemosensory technology
NASA Astrophysics Data System (ADS)
Gotor, Raúl; Gaviña, Pablo; Costero, Ana M.
2015-08-01
We report herein the construction of an electronic device to perform the real-time digitalization of the color state of the optical chemosensors used in the detection of dangerous gases. To construct the device, we used open-source modular electronics, such as Arduino and Sparkfun components, as well as free and open-source software (FOSS). The basic principle of the operation of this device is the continuous color measurement of a chemosensor-doped sensing film, whose color changes in the presence of a specific gas. The chemosensor-sensing film can be prepared by using any of the widely available chemosensors for the desired gas. Color measurement is taken by two TCS230 color sensor ICs, reported to the microcontroller, and the results are displayed on an LCD display and pushed through a USB serial port. By using a cyanide optical chemosensor, we demonstrated the operation of the device as a HCN gas detector at low concentrations.
An assessment of memristor intrinsic fluctuations: a measurement of single atomic motion
NASA Astrophysics Data System (ADS)
Borghetti, Julien; Yang, J. Joshua; Medeiros-Ribeiro, Gilberto; Williams, R. Stanley
2010-03-01
Memristors provides electrically tunable resistance for upcoming non-volatile memory and future neuromorphic computing. One of the key benefits of such a device is its scalability, which can be demonstrated from an architectural perspective as well as from a fundamental physics limit. 4D addressing schemes utilizing cross bar structures that can be stacked several layers high above the chip embodies unlimited addressing space. On the other limit, the basic operating principles of memristive devices allow one to reach storage of information in a single atom. In this report of nanoscale (sub 50nm) devices, we detect single atom fluctuations, which would then represent the ultimate limit for noise sources thus delineating the boundary conditions for circuit design. We show that electrically induced individual atom migrations do not affect the overall device atomic configuration until a critical bias where a single local fluctuation triggers a general atomic reconfiguration. This instability illustrates the robustness of the device non-volatility upon small electrical stress.
Labiris, N R; Dolovich, M B
2003-01-01
Research in the area of pulmonary drug delivery has gathered momentum in the last several years, with increased interest in using the lung as a means of delivering drugs systemically. Advances in device technology have led to the development of more efficient delivery systems capable of delivering larger doses and finer particles into the lung. As more efficient pulmonary delivery devices and sophisticated formulations become available, physicians and health professionals will have a choice of a wide variety of device and formulation combinations that will target specific cells or regions of the lung, avoid the lung's clearance mechanisms and be retained within the lung for longer periods. It is now recognized that it is not enough just to have inhalation therapy available for prescribing; physicians and other healthcare providers need a basic understanding of aerosol science, inhaled formulations, delivery devices, and bioequivalence of products to prescribe these therapies optimally. PMID:14616419
NASA Astrophysics Data System (ADS)
Xia, Jing; Huang, Yangqi; Zhang, Xichao; Kang, Wang; Zheng, Chentian; Liu, Xiaoxi; Zhao, Weisheng; Zhou, Yan
2017-10-01
Magnetic skyrmion is a topologically protected domain-wall structure at nanoscale, which could serve as a basic building block for advanced spintronic devices. Here, we propose a microwave field-driven skyrmionic device with the transistor-like function, where the motion of a skyrmion in a voltage-gated ferromagnetic nanotrack is studied by micromagnetic simulations. It is demonstrated that the microwave field can drive the motion of a skyrmion by exciting the propagating spin waves, and the skyrmion motion can be governed by a gate voltage. We also investigate the microwave current-assisted creation of a skyrmion to facilitate the operation of the transistor-like skyrmionic device on the source terminal. It is found that the microwave current with an appropriate frequency can reduce the threshold current density required for the creation of a skyrmion from the ferromagnetic background. The proposed transistor-like skyrmionic device operated with the microwave field and current could be useful for building future skyrmion-based circuits.
FDA preemption of drug and device labeling: who should decide what goes on a drug label?
Valoir, Tamsen; Ghosh, Shubha
2011-01-01
The Supreme Court decided an issue that is critical to consumer health and safety last year. In April 2009, the Supreme Court held that extensive FDA regulation of drugs did not preempt a state law claim that an additional warning on the label was necessary to make the drug reasonably safe for use. Thus, states--and even courts and juries--are now free to cast their vote on what a drug label should say. This is in direct contrast to medical devices, where the federal statute regulating medical devices expressly provides that state regulations are preempted. This Article discusses basic preemption principles and drugs, and explores the policy ramifications of pro- and anti-preemption policy in the healthcare industry.
Device physics vis-à-vis fundamental physics in Cold War America: the case of quantum optics.
Bromberg, Joan Lisa
2006-06-01
Historians have convincingly shown the close ties U.S. physicists had with the military during the Cold War and have raised the question of whether this alliance affected the content of physics. Some have asserted that it distorted physics, shifting attention from fundamental problems to devices. Yet the papers of physicists in quantum electronics and quantum optics, fields that have been exemplary for those who hold the distortion thesis, show that the same scientists who worked on military devices simultaneously pursued fundamental and foundational topics. This essay examines one such physicist, Marlan O. Scully, with attention to both his extensive foundational studies and the way in which his applied and basic researches played off each other.
Liquid-Crystal-Enabled Active Plasmonics: A Review
Si, Guangyuan; Zhao, Yanhui; Leong, Eunice Sok Ping; Liu, Yan Jun
2014-01-01
Liquid crystals are a promising candidate for development of active plasmonics due to their large birefringence, low driving threshold, and versatile driving methods. We review recent progress on the interdisciplinary research field of liquid crystal based plasmonics. The research scope of this field is to build the next generation of reconfigurable plasmonic devices by combining liquid crystals with plasmonic nanostructures. Various active plasmonic devices, such as switches, modulators, color filters, absorbers, have been demonstrated. This review is structured to cover active plasmonic devices from two aspects: functionalities and driven methods. We hope this review would provide basic knowledge for a new researcher to get familiar with the field, and serve as a reference for experienced researchers to keep up the current research trends. PMID:28788515
Loopback Tester: a synchronous communications circuit diagnostic device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maestas, J.H.
1986-07-01
The Loopback Tester is an Intel SBC 86/12A Single Board Computer and an Intel SBC 534 Communications Expansion Board configured and programmed to perform various basic or less. These tests include: (1) Data Communications Equipment (DCE) transmit timing detection (2) data rate measurement (3) instantaneous loopback indication and (4) bit error rate testing. It requires no initial setup after plug in, and can be used to locate the source of communications loss in a circuit. It can also be used to determine when crypto variable mismatch problems are the source of communications loss. This report discusses the functionality of themore » Loopback Tester as a diagnostic device. It also discusses the hardware and software which implements this simple yet reliable device.« less
NASA Astrophysics Data System (ADS)
Tanaka, Hiroshi; Hashimura, Shinji; Hiroo, Yasuaki
We present a program to learn ability to solve problems on engineering. This program is called “Experiments in creative engineering” in the department of mechanical engineering in Kurume National College of Technology advanced engineering school. In the program, students have to determine own theme and manufacture experimental devices or some machines by themselves. The students must also perform experiments to valid the function and performance of their devices by themselves. The restriction of the theme is to manufacture a device which function dose not basically exist in the world with limited cost (up to 20,000Yen) . As the results of questionnaire of students, the program would be very effective to the creative education for the students.
Soft errors in commercial off-the-shelf static random access memories
NASA Astrophysics Data System (ADS)
Dilillo, L.; Tsiligiannis, G.; Gupta, V.; Bosser, A.; Saigne, F.; Wrobel, F.
2017-01-01
This article reviews state-of-the-art techniques for the evaluation of the effect of radiation on static random access memory (SRAM). We detailed irradiation test techniques and results from irradiation experiments with several types of particles. Two commercial SRAMs, in 90 and 65 nm technology nodes, were considered as case studies. Besides the basic static and dynamic test modes, advanced stimuli for the irradiation tests were introduced, as well as statistical post-processing techniques allowing for deeper analysis of the correlations between bit-flip cross-sections and design/architectural characteristics of the memory device. Further insight is provided on the response of irradiated stacked layer devices and on the use of characterized SRAM devices as particle detectors.
Concerning the Spatial Heterodyne Spectrometer
Lenzner, Matthias; Diels, Jean -Claude
2016-01-22
A modified Spatial Heterodyne Spectrometer (SHS) is used for measuring atomic emission spectra with high resolution. This device is basically a Fourier Transform Spectrometer, but the Fourier transform is taken in the directions perpendicular to the optical propagation and heterodyned around one preset wavelength. In recent descriptions of this device, one specific phenomenon - the tilt of the energy front of wave packets when diffracted from a grating - was neglected. This led to an overestimate of the resolving power of this spectrograph, especially in situations when the coherence length of the radiation under test is in the order ofmore » the effective aperture of the device. In conclusion, the limits of usability are shown here together with some measurements of known spectral lines.« less
Efficient implementation of real-time programs under the VAX/VMS operating system
NASA Technical Reports Server (NTRS)
Johnson, S. C.
1985-01-01
Techniques for writing efficient real-time programs under the VAX/VMS oprating system are presented. Basic operations are presented for executing at real-time priority and for avoiding needlless processing delays. A highly efficient technique for accessing physical devices by mapping to the input/output space and accessing the device registrs directly is described. To illustrate the application of the technique, examples are included of different uses of the technique on three devices in the Langley Avionics Integration Research Lab (AIRLAB): the KW11-K dual programmable real-time clock, the Parallel Communications Link (PCL11-B) communication system, and the Datacom Synchronization Network. Timing data are included to demonstrate the performance improvements realized with these applications of the technique.
Makey, Ghaith; Elahi, Parviz; Çolakoğlu, Tahir; Ergeçen, Emre; Yavuz, Özgün; Hübner, René; Borra, Mona Zolfaghari; Pavlov, Ihor; Bek, Alpan; Turan, Raşit; Kesim, Denizhan Koray; Tozburun, Serhat; Ilday, Serim; Ilday, F. Ömer
2017-01-01
Silicon is an excellent material for microelectronics and integrated photonics1–3 with untapped potential for mid-IR optics4. Despite broad recognition of the importance of the third dimension5,6, current lithography methods do not allow fabrication of photonic devices and functional microelements directly inside silicon chips. Even relatively simple curved geometries cannot be realised with techniques like reactive ion etching. Embedded optical elements, like in glass7, electronic devices, and better electronic-photonic integration are lacking8. Here, we demonstrate laser-based fabrication of complex 3D structures deep inside silicon using 1 µm-sized dots and rod-like structures of adjustable length as basic building blocks. The laser-modified Si has a different optical index than unmodified parts, which enables numerous photonic devices. Optionally, these parts are chemically etched to produce desired 3D shapes. We exemplify a plethora of subsurface, i.e., “in-chip” microstructures for microfluidic cooling of chips, vias, MEMS, photovoltaic applications and photonic devices that match or surpass the corresponding state-of-the-art device performances. PMID:28983323
NASA Astrophysics Data System (ADS)
Tsutsumi, Toshiyuki
2018-06-01
The threshold voltage (V th) fluctuation induced by ion implantation (I/I) in the source and drain extensions (SDEs) of a silicon-on-insulator (SOI) triple-gate (Tri-Gate) fin-type field-effect transistor (FinFET) was analyzed by both three-dimensional (3D) process and device simulations collaboratively. The origin of the V th fluctuation induced by the SDE I/I is basically a variation of a bottleneck barrier height (BBH) due to implanted arsenic (As+) ions. In particular, a very low and broad V th distribution in the saturation region is due to percolative conduction in addition to the BBH variation. Moreover, it is surprisingly found that the V th fluctuation is mostly characterized by the BBH of only a top surface center line of a Si fin of the device. Our collaborative approach by 3D process and device simulations is dispensable for the accurate investigation of variability-tolerant devices. The obtained results are beneficial for the research and development of such future devices.
NASA Astrophysics Data System (ADS)
Tokel, Onur; Turnalı, Ahmet; Makey, Ghaith; Elahi, Parviz; ćolakoǧlu, Tahir; Ergeçen, Emre; Yavuz, Ã.-zgün; Hübner, René; Zolfaghari Borra, Mona; Pavlov, Ihor; Bek, Alpan; Turan, Raşit; Kesim, Denizhan Koray; Tozburun, Serhat; Ilday, Serim; Ilday, F. Ã.-mer
2017-10-01
Silicon is an excellent material for microelectronics and integrated photonics1-3, with untapped potential for mid-infrared optics4. Despite broad recognition of the importance of the third dimension5,6, current lithography methods do not allow the fabrication of photonic devices and functional microelements directly inside silicon chips. Even relatively simple curved geometries cannot be realized with techniques like reactive ion etching. Embedded optical elements7, electronic devices and better electronic-photonic integration are lacking8. Here, we demonstrate laser-based fabrication of complex 3D structures deep inside silicon using 1-µm-sized dots and rod-like structures of adjustable length as basic building blocks. The laser-modified Si has an optical index different to that in unmodified parts, enabling the creation of numerous photonic devices. Optionally, these parts can be chemically etched to produce desired 3D shapes. We exemplify a plethora of subsurface—that is, `in-chip'—microstructures for microfluidic cooling of chips, vias, micro-electro-mechanical systems, photovoltaic applications and photonic devices that match or surpass corresponding state-of-the-art device performances.
Total Ionizing Dose Effects in MOS Oxides and Devices
NASA Technical Reports Server (NTRS)
Oldham, Timothy R.; McLean, F. B.
2003-01-01
The development of military and space electronics technology has traditionally been heavily influenced by the commercial semiconductor industry. The development of MOS technology, and particularly CMOS technology, as dominant commercial technologies has occurred entirely within the lifetime of the NSREC. For this reason, it is not surprising that the study of radiation interactions with MOS materials, devices and circuits has been a major theme of this conference for most of its history. The basic radiation problem in a MOS transistor is illustrated. The application of an appropriate gate voltage causes a conducting channel to form between the source and drain, so that current flows when the device is turned on. In Fig. lb, the effect of ionizing radiation is illustrated. Radiation-induced trapped charge has built up in the gate oxide, which causes a shift in the threshold voltage (that is, a change in the voltage which must be applied to turn the device on). If this shift is large enough, the device cannot be turned off, even at zero volts applied, and the device is said to have failed by going depletion mode.
Small Form Factor Information Storage Devices for Mobile Applications in Korea
NASA Astrophysics Data System (ADS)
Park, Young-Pil; Park, No-Cheol; Kim, Chul-Jin
Recently, the ubiquitous environment in which anybody can reach a lot of information data without any limitations on the place and time has become an important social issue. There are two basic requirements in the field of information storage devices which have to be satisfied; the first is the demand for the improvement of memory capacity to manage the increased data capacity in personal and official purposes. The second is the demand for new development of information storage devices small enough to be applied to mobile multimedia digital electronics, including digital camera, PDA and mobile phones. To summarize, for the sake of mobile applications, it is necessary to develop information storage devices which have simultaneously a large capacity and a small size. Korea possesses the necessary infrastructure for developing such small sized information storage devices. It has a good digital market, major digital companies, and various research institutes. Nowadays, many companies and research institutes including university cooperate together in the research on small sized information storage devices. Thus, it is expected that small form factor optical disk drives will be commercialized in the very near future in Korea.
Formalization, equivalence and generalization of basic resonance electrical circuits
NASA Astrophysics Data System (ADS)
Penev, Dimitar; Arnaudov, Dimitar; Hinov, Nikolay
2017-12-01
In the work are presented basic resonance circuits, which are used in resonance energy converters. The following resonant circuits are considered: serial, serial with parallel load parallel capacitor, parallel and parallel with serial loaded inductance. For the circuits under consideration, expressions are generated for the frequencies of own oscillations and for the equivalence of the active power emitted in the load. Mathematical expressions are graphically constructed and verified using computer simulations. The results obtained are used in the model based design of resonant energy converters with DC or AC output. This guaranteed the output indicators of power electronic devices.
CFD Approach To Investigate The Flow Characteristics In Bi-Directional Ventilated Disc Brake
NASA Astrophysics Data System (ADS)
Munisamy, Kannan M.; Yusoff, Mohd. Zamri; Shuaib, Norshah Hafeez; Thangaraju, Savithry K.
2010-06-01
This paper presents experimental and Computational Fluids Dynamics (CFD) investigations of the flow in ventilated brake discs. Development of an experiment rig with basic measuring devices are detailed out and following a validation study, the possible improvement in the brake cooling can be further analyzed using CFD analysis. The mass flow rate is determined from basic flow measurement technique following that the conventional bi-directional passenger car is simulated using commercial CFD software FLUENT™. The CFD simulation is used to investigate the flow characteristics in between blade flow of the bi-directional ventilated disc brake.
The phototron: A light to RF energy conversion device
NASA Technical Reports Server (NTRS)
Freeman, J. W.; Simons, S.
1982-01-01
The phototron, a photoelectric device that converts light to radio frequency energy, is described. It is a vacuum tube, free electron, device that is mechanically similar to a reflex klystron with the hot filament cathode replaced by a large area photocathode. The device can operate either with an external voltage source used to accelerate the photoelectrons or with zero bias voltage; in which case the photokinetic energy of the electrons sustains the R.F. oscillations in the tuned R.F. circuit. One basic design of the phototron was tested. Frequencies as high as about 1 GHz and an overall efficiency of about 1% in the biased mode were obtained. In the unbiased mode, the frequencies of operation and efficiences are considerably lower. Success with test model suggests that considerable improvements are possible through design refinements. One such design refinement is the reduction of the length of the electron flight path.
Humidification during mechanical ventilation in the adult patient.
Al Ashry, Haitham S; Modrykamien, Ariel M
2014-01-01
Humidification of inhaled gases has been standard of care in mechanical ventilation for a long period of time. More than a century ago, a variety of reports described important airway damage by applying dry gases during artificial ventilation. Consequently, respiratory care providers have been utilizing external humidifiers to compensate for the lack of natural humidification mechanisms when the upper airway is bypassed. Particularly, active and passive humidification devices have rapidly evolved. Sophisticated systems composed of reservoirs, wires, heating devices, and other elements have become part of our usual armamentarium in the intensive care unit. Therefore, basic knowledge of the mechanisms of action of each of these devices, as well as their advantages and disadvantages, becomes a necessity for the respiratory care and intensive care practitioner. In this paper, we review current methods of airway humidification during invasive mechanical ventilation of adult patients. We describe a variety of devices and describe the eventual applications according to specific clinical conditions.
Fundamentals of Digital Engineering: Designing for Reliability
NASA Technical Reports Server (NTRS)
Katz, R.; Day, John H. (Technical Monitor)
2001-01-01
The concept of designing for reliability will be introduced along with a brief overview of reliability, redundancy and traditional methods of fault tolerance is presented, as applied to current logic devices. The fundamentals of advanced circuit design and analysis techniques will be the primary focus. The introduction will cover the definitions of key device parameters and how analysis is used to prove circuit correctness. Basic design techniques such as synchronous vs asynchronous design, metastable state resolution time/arbiter design, and finite state machine structure/implementation will be reviewed. Advanced topics will be explored such as skew-tolerant circuit design, the use of triple-modular redundancy and circuit hazards, device transients and preventative circuit design, lock-up states in finite state machines generated by logic synthesizers, device transient characteristics, radiation mitigation techniques. worst-case analysis, the use of timing analyzer and simulators, and others. Case studies and lessons learned from spaceflight designs will be given as examples
Pricing and reimbursement of drugs and medical devices in Hungary.
Gulácsi, L; Dávid, T; Dózsa, Cs
2002-01-01
Similarly to other countries of Central and Eastern Europe, Hungary has witnessed massive diffusion of healthcare technology such as drugs and medical devices since 1990. While substantial new pharmaceuticals, medical devices, and procedures have been liberalized, there has been no proper evaluation or training in their use. Healthcare providers have come to find themselves as entrepreneurs in private practice, while patients are acquiring an increasing awareness as customers of healthcare,demanding services in return for their taxes and contributions. This has led to extremely irrational patterns of investment in technology, with most an obvious waste of resources, while leaving basic needs unmet. Both the National Health Insurance Fund and the Ministry of Finance believe that the current pharmaceutical and medical device bill is too high. However, introducing a more transparent and flexible pricing and reimbursement framework may enable a more efficient allocation of the limited resources to be achieved.
NASA Technical Reports Server (NTRS)
Long, D. M.
1982-01-01
The results of research concerning the effects of nuclear and space radiation are presented. Topics discussed include the basic mechanisms of nuclear and space radiation effects, radiation effects in devices, and radiation effects in microcircuits, including studies of radiation-induced paramagnetic defects in MOS structures, silicon solar cell damage from electrical overstress, radiation-induced charge dynamics in dielectrics, and the enhanced radiation effects on submicron narrow-channel NMOS. Also examined are topics in SGEMP/IEMP phenomena, hardness assurance and testing, energy deposition, desometry, and radiation transport, and single event phenomena. Among others, studies are presented concerning the limits to hardening electronic boxes to IEMP coupling, transient radiation screening of silicon devices using backside laser irradiation, the damage equivalence of electrons, protons, and gamma rays in MOS devices, and the single event upset sensitivity of low power Schottky devices.
Piezo-Phototronic Effect in a Quantum Well Structure.
Huang, Xin; Du, Chunhua; Zhou, Yongli; Jiang, Chunyan; Pu, Xiong; Liu, Wei; Hu, Weiguo; Chen, Hong; Wang, Zhong Lin
2016-05-24
With enhancements in the performance of optoelectronic devices, the field of piezo-phototronics has attracted much attention, and several theoretical works have been reported based on semiclassical models. At present, the feature size of optoelectronic devices are rapidly shrinking toward several tens of nanometers, which results in the quantum confinement effect. Starting from the basic piezoelectricity equation, Schrödinger equation, Poisson equation, and Fermi's golden rule, a self-consistent theoretical model is proposed to study the piezo-phototronic effect in the framework of perturbation theory in quantum mechanics. The validity and universality of this model are well-proven with photoluminescence measurements in a single GaN/InGaN quantum well and multiple GaN/InGaN quantum wells. This study provides important insight into the working principle of nanoscale piezo-phototronic devices as well as guidance for the future device design.
Control Structures for VSC-based FACTS Devices under Normal and Faulted AC-systems
NASA Astrophysics Data System (ADS)
Babaei, Saman
This thesis is concerned with improving the Flexible AC Transmission Systems (FACTS) devices performance under the normal and fault AC-system conditions by proposing new control structures and also converter topologies. The combination of the increasing electricity demand and restrictions in expanding the power system infrastructures has urged the utility owners to deploy the utility-scaled power electronics in the power system. Basically, FACTS is referred to the application of the power electronics in the power systems. Voltage Source Converter (VSC) is the preferred building block of the FACTS devices and many other utility-scale power electronics applications. Despite of advances in the semiconductor technology and ultra-fast microprocessor based controllers, there are still many issues to address and room to improve[25]. An attempt is made in this thesis to address these important issues of the VSC-based FACTS devices and provide solutions to improve them.
MEMS reliability: coming of age
NASA Astrophysics Data System (ADS)
Douglass, Michael R.
2008-02-01
In today's high-volume semiconductor world, one could easily take reliability for granted. As the MOEMS/MEMS industry continues to establish itself as a viable alternative to conventional manufacturing in the macro world, reliability can be of high concern. Currently, there are several emerging market opportunities in which MOEMS/MEMS is gaining a foothold. Markets such as mobile media, consumer electronics, biomedical devices, and homeland security are all showing great interest in microfabricated products. At the same time, these markets are among the most demanding when it comes to reliability assurance. To be successful, each company developing a MOEMS/MEMS device must consider reliability on an equal footing with cost, performance and manufacturability. What can this maturing industry learn from the successful development of DLP technology, air bag accelerometers and inkjet printheads? This paper discusses some basic reliability principles which any MOEMS/MEMS device development must use. Examples from the commercially successful and highly reliable Digital Micromirror Device complement the discussion.
Main principles of developing exploitation models of semiconductor devices
NASA Astrophysics Data System (ADS)
Gradoboev, A. V.; Simonova, A. V.
2018-05-01
The paper represents primary tasks, solutions of which allow to develop the exploitation modes of semiconductor devices taking into account complex and combined influence of ionizing irradiation and operation factors. The structure of the exploitation model of the semiconductor device is presented, which is based on radiation and reliability models. Furthermore, it was shown that the exploitation model should take into account complex and combine influence of various ionizing irradiation types and operation factors. The algorithm of developing the exploitation model of the semiconductor devices is proposed. The possibility of creating the radiation model of Schottky barrier diode, Schottky field-effect transistor and Gunn diode is shown based on the available experimental data. The basic exploitation model of IR-LEDs based upon double AlGaAs heterostructures is represented. The practical application of the exploitation models will allow to output the electronic products with guaranteed operational properties.
Self-reported tactics of impulse control.
Ainslie, G
1987-02-01
Recent behavioral research has suggested that delayed incentives are discounted in a highly concave curve, which should produce temporary preference for the poorer of two alternatives when that alternative is available earlier than the better one. Unlike the psychoanalytic model of impulsiveness, the temporary preference model implies a rational need for people to forestall impulses by committing their choices in advance. A questionnaire elicited college students' and prisoners' self-reports of approval of four basic kinds of precommitting tactics as applied to 14 commonplace temptations. Endorsement of private rules as a precommitting device was correlated with self-reported compulsive personality traits and negatively correlated with endorsement of extra-psychic (social or physical) devices; the latter endorsement was correlated with self-reported oral/paranoid traits. Female subjects endorsed attention control as a precommitting device more than males, and male subjects endorsed extrapsychic devices more than females. The ego psychology of conflict may be practical at the conscious level.
Nanoelectronics: Opportunities for future space applications
NASA Technical Reports Server (NTRS)
Frazier, Gary
1995-01-01
Further improvements in the performance of integrated electronics will eventually halt due to practical fundamental limits on our ability to downsize transistors and interconnect wiring. Avoiding these limits requires a revolutionary approach to switching device technology and computing architecture. Nanoelectronics, the technology of exploiting physics on the nanometer scale for computation and communication, attempts to avoid conventional limits by developing new approaches to switching, circuitry, and system integration. This presentation overviews the basic principles that operate on the nanometer scale that can be assembled into practical devices and circuits. Quantum resonant tunneling (RT) is used as the center-piece of the overview since RT devices already operate at high temperature (120 degrees C) and can be scaled, in principle, to a few nanometers in semiconductors. Near- and long-term applications of GaAs and silicon quantum devices are suggested for signal and information processing, memory, optoelectronics, and radio frequency (RF) communication.
Design of point-of-care (POC) microfluidic medical diagnostic devices
NASA Astrophysics Data System (ADS)
Leary, James F.
2018-02-01
Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically < 15 minutes) medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.
Interfacial and Surface Science | Materials Science | NREL
-flight SIMS (TOF-SIMS) provides surface spectroscopy of both inorganic and organic materials, and is Chamber This tool enables deposition of inorganic chalcogenides and for basic material and device studies lead halide perovskites and semiconductor quantum dots. Contact: Craig Perkins | Email | 303-384-6659
MPA-11: Materials Synthesis and Integrated Devices; Overview of an Applied Energy Group
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dattelbaum, Andrew Martin
Our mission is to provide innovative and creative chemical synthesis and materials science solutions to solve materials problems across the LANL missions. Our group conducts basic and applied research in areas related to energy security as well as problems relevant to the Weapons Program.
24 CFR 3280.602 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-04-01
... operator. Plumbing appurtenance: means a manufactured device, or a prefabricated assembly, or an on-the-job assembly of component parts, and which is an adjunct to the basic piping system and plumbing system and... following two types, or a combination of the two: (a) Self-siphonage resulting from vacuum in a fixture...
Internal Ballistics of a Pneumatic Potato Cannon
ERIC Educational Resources Information Center
Mungan, Carl E.
2009-01-01
Basic laws of thermodynamics and mechanics are used to analyse an air gun. Such devices are often employed in outdoor physics demonstrations to launch potatoes using compressed gas that is here assumed to expand reversibly and adiabatically. Reasonable agreement is found with reported muzzle speeds for such homebuilt cannons. The treatment is…
Demonstrating the Light-Emitting Diode.
ERIC Educational Resources Information Center
Johnson, David A.
1995-01-01
Describes a simple inexpensive circuit which can be used to quickly demonstrate the basic function and versatility of the solid state diode. Can be used to demonstrate the light-emitting diode (LED) as a light emitter, temperature sensor, light detector with both a linear and logarithmic response, and charge storage device. (JRH)
ERIC Educational Resources Information Center
Roy, Ken
2010-01-01
Batteries commonly used in flashlights and other household devices produce hydrogen gas as a product of zinc electrode corrosion. The amount of gas produced is affected by the batteries' design and charge rate. Dangerous levels of hydrogen gas can be released if battery types are mixed, batteries are damaged, batteries are of different ages, or…
The report explains the basic concepts of in-stack opacity as measured by in-stack opacity monitors. Also included are calculator programs that model the performance of venturi scrubbers and electrostatic precipitators. The effect of particulate control devices on in-stack opacit...
Measuring Time on the PET and Other Microcomputers
ERIC Educational Resources Information Center
Tesler, Larry
1978-01-01
The operation of the microcomputer requires one or more clocks or timers to measure intervals of different magnitudes. Methods are discussed for measuring time intervals on PET in hours, minutes, seconds, microseconds, miscellaneous units, and timing events on external devices. Directions are added for BASIC program applications of timing…
ERIC Educational Resources Information Center
Clarken, Rodney H.
Metaphors are effective rhetorical devices to explain ideas, organize information, and illuminate understanding. Metaphor is a process of comparing and identifying one thing with another. Two basic principles of instruction are to go from the known to the unknown and to go from the concrete to the abstract. Metaphors do this by using concrete…
Module Ten: Transformers; Basic Electricity and Electronics Individualized Learning System.
ERIC Educational Resources Information Center
Bureau of Naval Personnel, Washington, DC.
The module introduces a very important electrical device, the transformer. The module is divided into six lessons: transformer construction, transformer theory and operation, turns and voltage ratios, power and current, transformer efficiency, and semiconductor rectifiers. Each lesson consists of an overview, a list of study resources, lesson…
Propellers And Fans Based On The Moebius Strip
NASA Technical Reports Server (NTRS)
Seiner, John Milton; Gilinsky, Mikhail Markovich
1996-01-01
Moebius strip proposed as basis for optimally shaped airplane and boat propellers, fans, helicopter rotors, mixing screws, coffee grinders, and concrete mixers. Basic idea of optimal shaping of such device to increase working efficiency by increasing area for capture of still medium without increasing power needed for rotation.
Secondary School Projects and the Microchip.
ERIC Educational Resources Information Center
Irvine, A. F.
This study of the applications of microelectronic devices in industry, together with an assessment of their value for use in schools, emphasizes the basic principles underlying the new technology and the practical ways in which these can contribute to associated work in computing and other disciplines in the school curriculum. Following a…
basic research on the optical and electronic properties of semiconductor alloys for photovoltaic and , Berkeley in 2008, where she studied the optical and electronic properties of highly mismatched semiconductor alloys. She came to NREL as a postdoctoral researcher in the Silicon Materials and Devices group
Computer Service Technician "COMPS." Curriculum Grant 1985.
ERIC Educational Resources Information Center
Schoolcraft Coll., Livonia, MI.
This document is a curriculum guide for a program in computer service technology developed at Schoolcraft College, Livonia, Michigan. The program is designed to give students a strong background in the fundamentals of electricity, electronic devices, and basic circuits (digital and linear). The curriculum includes laboratory demonstrations of the…
Student Human Potential: Going beyond the Basics.
ERIC Educational Resources Information Center
White, Sylvia Ann
The expansion of human potential and the accompanying increase in self-esteem and self-actualization is the key to emotional and physical health, social relations, learning problems, self-discipline, and future survival. Self-knowledge, obtained through such measures as keeping records of moods and through biomechanical devices, can enable…
Robotics for Computer Scientists: What's the Big Idea?
ERIC Educational Resources Information Center
Touretzky, David S.
2013-01-01
Modern robots, like today's smartphones, are complex devices with intricate software systems. Introductory robot programming courses must evolve to reflect this reality, by teaching students to make use of the sophisticated tools their robots provide rather than reimplementing basic algorithms. This paper focuses on teaching with Tekkotsu, an open…
Fabrication and Performance of Large Format Transition Edge Sensor Microcalorimeter Arrays
NASA Technical Reports Server (NTRS)
Chervenak, James A.; Adams, James S.; Bandler, Simon R.; Busch, Sara E.; Eckart, M. E.; Ewin, A. E.; Finkbeiner, F. M.; Kilbourne, C. A.; Kelley, R. L.; Porst, Jan-Patrick;
2012-01-01
We have produced a variety of superconducting transition edge sensor array designs for microcalorimetric detection of x-rays. Designs include kilopixel scale arrays of relatively small sensors (75 micron pitch) atop a thick metal heatsinking layer as well as arrays of membrane-isolated devices on 250 micron pitch and smaller arrays of devices up to 600 micron pitch. We discuss the fabrication techniques used for each type of array focusing on unique aspects where processes vary to achieve the particular designs and required device parameters. For example, we evaluate various material combinations in the production of the thick metal heatsinking, including superconducting and normal metal adhesion layers. We also evaluate the impact of added heatsinking on the membrane isolated devices as it relates to basic device parameters. Arrays can be characterized with a time division SQUID multiplexer such that greater than 10 devices from an array can be measured in the same cooldown. Device parameters can be measured simultaneously so that environmental events such as thermal drifts or changes in magnetic fields can be controlled. For some designs, we will evaluate the uniformity of parameters impacting the intrinsic performance of the microcalorimeters under bias in these arrays and assess the level of thermal crosstalk.
Mesenchymal Stem Cells in Lipogems, a Reverse Story: from Clinical Practice to Basic Science.
Tremolada, Carlo; Ricordi, Camillo; Caplan, Arnold I; Ventura, Carlo
2016-01-01
The idea that basic science should be the starting point for modern clinical approaches has been consolidated over the years, and emerged as the cornerstone of Molecular Medicine. Nevertheless, there is increasing concern over the low efficiency and inherent costs related to the translation of achievements from the bench to the bedside. These burdens are also perceived with respect to the effectiveness of translating basic discoveries in stem cell biology to the newly developing field of advanced cell therapy or Regenerative Medicine. As an alternative paradigm, past and recent history in Medical Science provides remarkable reverse stories in which clinical observations at the patient's bedside have fed major advances in basic research which, in turn, led to consistent progression in clinical practice. Within this context, we discuss our recently developed method and device, which forms the core of a system (Lipogems) for processing of human adipose tissue solely with the aid of mild mechanical forces to yield a microfractured tissue product.
Iwazaki, Keigo; Kojima, Toshiya; Murasawa, Takahide; Yokota, Jun; Tanimoto, Hikaru; Matsuda, Jun; Fukuma, Nobuaki; Matsubara, Takumi; Shimizu, Yu; Oguri, Gaku; Hasumi, Eriko; Kubo, Hitoshi; Chang, Kyungho; Fujiu, Katsuhito; Komuro, Issei
2018-05-30
A cardiac resynchronization therapy defibrillator (CRT-D) (Medtronic Inc. Protecta XT) was implanted in a 67-year-old man who had cardiac sarcoidosis with extremely low cardiac function. He had ventricular tachycardia which was controlled by catheter ablation, medication and pacing. The programmed mode was DDI, lower rate was 90 beats/minute, paced AV delay was 150 ms, and the noncompetitive atrial pacing (NCAP) function was programmed as 300 ms.After his admission for pneumonia and heart failure, we changed his DDI mode to a DDD mode because he had atrial tachycardia, which led to inadequate bi-ventricular pacing. After a while, there were cycle lengths which were longer than his device setting and alternately varied. We were able to avoid this phenomenon with AV delay of 120 ms and NCAP of 200 ms.NCAP is an algorithm which creates a gap above a certain period after the detection of an atrial signal during the postventricular atrial refractory period of the pacemaker. This is to prevent atrial tachycardia and repetitive non-reentrant ventriculoatrial (VA) synchrony in the presence of retrograde VA conduction. But in this case, NCAP algorithm induced much lower rate than the programmed basic lower rate. This situation produced some arrhythmias and exacerbated symptoms of heart failure. This had to be paid attention to, especially when the device was programmed at high basic heart rate.
Determining Desirable Cursor Control Device Characteristics for NASA Exploration Missions
NASA Technical Reports Server (NTRS)
Sandor, Aniko; Holden, Kritina
2007-01-01
The Crew Exploration Vehicle (CEV) that will travel to the moon and Mars, and all future Exploration vehicles and habitats will be highly computerized, necessitating an accurate method of interaction with the computers. The design of a cursor control device will have to take into consideration g-forces, vibration, gloved operations, and the specific types of tasks to be performed. The study described here is being undertaken to begin identifying characteristics of cursor control devices that will work well for the unique Exploration mission environments. The objective of the study is not to identify a particular device, but to begin identifying design characteristics that are usable and desirable for space missions. Most cursor control devices have strengths and weaknesses; they are more appropriate for some tasks and less suitable for others. The purpose of this study is to collect some initial usability data on a large number of commercially available and proprietary cursor control devices. A software test battery was developed for this purpose. Once data has been collected using these low-level, basic point/click/drag tasks, higher fidelity, scenario-driven evaluations will be conducted with a reduced set of devices. The standard tasks used for testing cursor control devices are based on a model of human movement known as Fitts law. Fitts law predicts that the time to acquire a target is logarithmically related to the distance over the target size. To gather data for analysis with this law, fundamental, low-level tasks are used such as dragging or pointing at various targets of different sizes from various distances. The first four core tasks for the study were based on the ISO 9241-9:(2000) document from the International Organization for Standardization that contains the requirements for non-keyboard input devices. These include two pointing tasks, one dragging and one tracking task. The fifth task from ISO 9241-9, the circular tracking task was not used because it is a movement that is not applicable to most of the applications used on aviation displays. Additionally, we opted to add a multi-size and multi-distance pointing task, and two ecologically more valid tasks which included text selection, and interaction with drop down menus, sliders, and checkboxes. The Visual Basic test battery tracks the task and trial numbers, measures the pointing, tracking or dragging time, as well as the number and types of errors. The testing session includes a practice set for each input device, then the randomized 7 tasks, and finally a questionnaire about the device. This is repeated for all the devices tested within a session. The experiment is a within-subjects design, with participants returning for multiple sessions to test additional devices. The input devices will be compared based on objective performance data from the tasks, as well as subjective feedback and ratings on the questionnaire.
Dynamic MEMS devices for multi-axial fatigue and elastic modulus measurement
NASA Astrophysics Data System (ADS)
White, Carolyn D.; Xu, Rui; Sun, Xiaotian; Komvopoulos, Kyriakos
2003-01-01
For reliable MEMS device fabrication and operation, there is a continued demand for precise characterization of materials at the micron scale. This paper presents a novel material characterization device for fatigue lifetime testing. The fatigue specimen is subjected to multi-axial loading, which is typical of most MEMS devices. Polycrystalline silicon (polysilicon) fatigue devices were fabricated using the MUMPS process with a three layer mask process ground plane, anchor, and structural layer of polysilicon. A fatigue device consists of two or three beams, attached to a rotating ring and anchored to the substrate on each end. In order to generate a sufficiently large stress, the fatigue devices were tested in resonance to produce a von Mises equivalent stress as high as 1 GPa, which is in the fracture strength range reported for polysilicon. A further increase of the stress in the beam specimens was obtained by introducing a notch with a focused ion beam. The notch resulted into a stress concentration factor of about 3.8, thereby producing maximum von Mises equivalent stress in the range of 1 through 4 GPa. This study provides insight into multi-axial fatigue testing under typical MEMS conditions and additional information about micron-scale polysilicon mechanical behavior, which is the current basic building material for MEMS devices.
Tests of monolithic active pixel sensors at national synchrotron light source
NASA Astrophysics Data System (ADS)
Deptuch, G.; Besson, A.; Carini, G. A.; Siddons, D. P.; Szelezniak, M.; Winter, M.
2007-01-01
The paper discusses basic characterization of Monolithic Active Pixel Sensors (MAPS) carried out at the X12A beam-line at National Synchrotron Light Source (NSLS), Upton, NY, USA. The tested device was a MIMOSA V (MV) chip, back-thinned down to the epitaxial layer. This 1M pixels device features a pixel size of 17×17 μm2 and was designed in a 0.6 μm CMOS process. The X-ray beam energies used range from 5 to 12 keV. Examples of direct X-ray imaging capabilities are presented.
Quantum model of light transmission in array waveguide gratings.
Capmany, J; Mora, J; Fernández-Pousa, C R; Muñoz, P
2013-06-17
We develop, to the best of our knowledge, the first model for an array waveguide grating (AWG) device subject to quantum inputs and analyze its basic transformation functionalities for single-photon states. A commercial, cyclic AWG is experimentally characterized with weak input coherent states as a means of exploring its behaviour under realistic quantum detection. In particular it is shown the existence of a cutoff value of the average photon number below which quantum crosstalk between AWG ports is negligible with respect to dark counts. These results can be useful when considering the application of AWG devices to integrated quantum photonic systems.
Cronin, Brett; Essandoh, Michael K
2018-04-01
Feelings of trepidation or uncertainty regarding cardiovascular implantable electronic devices (CIEDs) in the perioperative period can often be mitigated by a thorough knowledge of societal recommendations, recommended management options, and familiarity with CIEDs. Given that effective interpretation of an interrogation report is vital to determining perioperative management options and applying societal recommendations, the creation and interpretation of St. Jude CIED interrogation reports are discussed. In an effort to increase the familiarity with St. Jude transvenous CIEDs amongst anesthesiologists, basic programming of a St. Jude pacemaker and implantable cardioverter defibrillator (ICD) also are described. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Detistov, Pavel; Balabanski, Dimiter L.
2015-04-01
This work work is a part of the performance investigation of the recently constructed Mini-Orange beta spectrometer. The spectrometer has eight different configurations using three different magnet shapes and combination of three, four, and six magnet pieces allowing detection of electrons in wide kinetic energy range. The performance of the device is studied using the GEANT4 simulation tool. Evaluation of the device's basic parameters has been made, paying special attention to the backscattering, for which a study of the dependence of this process on the energy and the angle is made.
NREL Photovoltaic Program FY 1995 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-01
This report summarizes the in-house and subcontracted R&D activities from Oct. 1994 through Sept. 1995; their objectives are to conduct basic, applied, and engineering research, manage subcontracted R&D projects, perform research complementary to subcontracted work, develop and maintain state-of-the-art measurement and device capabilities, develop PV manufacturing technology and modules, transfer results to industry, and evolve viable partnerships for PV systems and market development. The research activities are grouped into 5 sections: crystalline Si and advanced devices, thin-film PV, PV manufacturing, PV module and system performance and engineering, and PV applications and market development.
Nonreciprocal reflection-beam isolators for far-infrared use
NASA Technical Reports Server (NTRS)
Kanda, M.; May, W. G.
1973-01-01
Magnetoplasma reflection-beam isolators for submillimeter-wave use are discussed in theory and experiment. The basic device uses the Kerr transverse magnetooptic effect (plane of polarization of the EM wave in the plane of incidence, which is perpendicular to a dc magnetic field) in InSb near room temperature. When the semiconductor slab is covered with a thin dielectric layer acting as a matching transformer, improved performance is predicted and observed at 337 microns, and very efficient isolator performance is predicted for 118 microns. Physical arguments are presented to explain the nonreciprocal phenomenon and lead to better device design.
Method for Reading Sensors and Controlling Actuators Using Audio Interfaces of Mobile Devices
Aroca, Rafael V.; Burlamaqui, Aquiles F.; Gonçalves, Luiz M. G.
2012-01-01
This article presents a novel closed loop control architecture based on audio channels of several types of computing devices, such as mobile phones and tablet computers, but not restricted to them. The communication is based on an audio interface that relies on the exchange of audio tones, allowing sensors to be read and actuators to be controlled. As an application example, the presented technique is used to build a low cost mobile robot, but the system can also be used in a variety of mechatronics applications and sensor networks, where smartphones are the basic building blocks. PMID:22438726
Hendler, Netta; Wildeman, Jurjen; Mentovich, Elad D; Schnitzler, Tobias; Belgorodsky, Bogdan; Prusty, Deepak K; Rimmerman, Dolev; Herrmann, Andreas; Richter, Shachar
2014-03-01
Optically active bio-composite blends of conjugated polymers or oligomers are fabricated by complexing them with bovine submaxilliary mucin (BSM) protein. The BSM matrix is exploited to host hydrophobic extended conjugated π-systems and to prevent undesirable aggregation and render such materials water soluble. This method allows tuning the emission color of solutions and films from the basic colors to the technologically challenging white emission. Furthermore, electrically driven light emitting biological devices are prepared and operated. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Ghosh, Amal K.; Basuray, Amitabha
2008-11-01
The memory devices in multi-valued logic are of most significance in modern research. This paper deals with the implementation of basic memory devices in multi-valued logic using Savart plate and spatial light modulator (SLM) based optoelectronic circuits. Photons are used here as the carrier to speed up the operations. Optical tree architecture (OTA) has been also utilized in the optical interconnection network. We have exploited the advantages of Savart plates, SLMs and OTA and proposed the SLM based high speed JK, D-type and T-type flip-flops in a trinary system.
Parts plus pipes: synthetic biology approaches to metabolic engineering
Boyle, Patrick M.; Silver, Pamela A.
2011-01-01
Synthetic biologists combine modular biological “parts” to create higher-order devices. Metabolic engineers construct biological “pipes” by optimizing the microbial conversion of basic substrates to desired compounds. Many scientists work at the intersection of these two philosophies, employing synthetic devices to enhance metabolic engineering efforts. These integrated approaches promise to do more than simply improve product yields; they can expand the array of products that are tractable to produce biologically. In this review, we explore the application of synthetic biology techniques to next-generation metabolic engineering challenges, as well as the emerging engineering principles for biological design. PMID:22037345
Method for reading sensors and controlling actuators using audio interfaces of mobile devices.
Aroca, Rafael V; Burlamaqui, Aquiles F; Gonçalves, Luiz M G
2012-01-01
This article presents a novel closed loop control architecture based on audio channels of several types of computing devices, such as mobile phones and tablet computers, but not restricted to them. The communication is based on an audio interface that relies on the exchange of audio tones, allowing sensors to be read and actuators to be controlled. As an application example, the presented technique is used to build a low cost mobile robot, but the system can also be used in a variety of mechatronics applications and sensor networks, where smartphones are the basic building blocks.
Choice of mathematical models for technological process of glass rod drawing
NASA Astrophysics Data System (ADS)
Alekseeva, L. B.
2017-10-01
The technological process of drawing glass rods (light guides) is considered. Automated control of the drawing process is reduced to the process of making decisions to ensure a given quality. The drawing process is considered as a control object, including the drawing device (control device) and the optical fiber forming zone (control object). To study the processes occurring in the formation zone, mathematical models are proposed, based on the continuum mechanics basics. To assess the influence of disturbances, a transfer function is obtained from the basis of the wave equation. Obtaining the regression equation also adequately describes the drawing process.
Getting started with open-hardware: development and control of microfluidic devices.
da Costa, Eric Tavares; Mora, Maria F; Willis, Peter A; do Lago, Claudimir L; Jiao, Hong; Garcia, Carlos D
2014-08-01
Understanding basic concepts of electronics and computer programming allows researchers to get the most out of the equipment found in their laboratories. Although a number of platforms have been specifically designed for the general public and are supported by a vast array of on-line tutorials, this subject is not normally included in university chemistry curricula. Aiming to provide the basic concepts of hardware and software, this article is focused on the design and use of a simple module to control a series of PDMS-based valves. The module is based on a low-cost microprocessor (Teensy) and open-source software (Arduino). The microvalves were fabricated using thin sheets of PDMS and patterned using CO2 laser engraving, providing a simple and efficient way to fabricate devices without the traditional photolithographic process or facilities. Synchronization of valve control enabled the development of two simple devices to perform injection (1.6 ± 0.4 μL/stroke) and mixing of different solutions. Furthermore, a practical demonstration of the utility of this system for microscale chemical sample handling and analysis was achieved performing an on-chip acid-base titration, followed by conductivity detection with an open-source low-cost detection system. Overall, the system provided a very reproducible (98%) platform to perform fluid delivery at the microfluidic scale. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A spelling device for the paralysed
NASA Astrophysics Data System (ADS)
Birbaumer, N.; Ghanayim, N.; Hinterberger, T.; Iversen, I.; Kotchoubey, B.; Kübler, A.; Perelmouter, J.; Taub, E.; Flor, H.
1999-03-01
When Jean-Dominique Bauby suffered from a cortico-subcortical stroke that led to complete paralysis with totally intact sensory and cognitive functions, he described his experience in The Diving-Bell and the Butterfly as ``something like a giant invisible diving-bell holds my whole body prisoner''. This horrifying condition also occurs as a consequence of a progressive neurological disease, amyotrophic lateral sclerosis, which involves progressive degeneration of all the motor neurons of the somatic motor system. These `locked-in' patients ultimately become unable to express themselves and to communicate even their most basic wishes or desires, as they can no longer control their muscles to activate communication devices. We have developed a new means of communication for the completely paralysed that uses slow cortical potentials (SCPs) of the electro-encephalogram to drive an electronic spelling device.
Hernando, M Elena; Pascual, Mario; Salvador, Carlos H; García-Sáez, Gema; Rodríguez-Herrero, Agustín; Martínez-Sarriegui, Iñaki; Gómez, Enrique J
2008-09-01
The growing availability of continuous data from medical devices in diabetes management makes it crucial to define novel information technology architectures for efficient data storage, data transmission, and data visualization. The new paradigm of care demands the sharing of information in interoperable systems as the only way to support patient care in a continuum of care scenario. The technological platforms should support all the services required by the actors involved in the care process, located in different scenarios and managing diverse information for different purposes. This article presents basic criteria for defining flexible and adaptive architectures that are capable of interoperating with external systems, and integrating medical devices and decision support tools to extract all the relevant knowledge to support diabetes care.
The modeling of MMI structures for signal processing applications
NASA Astrophysics Data System (ADS)
Le, Thanh Trung; Cahill, Laurence W.
2008-02-01
Microring resonators are promising candidates for photonic signal processing applications. However, almost all resonators that have been reported so far use directional couplers or 2×2 multimode interference (MMI) couplers as the coupling element between the ring and the bus waveguides. In this paper, instead of using 2×2 couplers, novel structures for microring resonators based on 3×3 MMI couplers are proposed. The characteristics of the device are derived using the modal propagation method. The device parameters are optimized by using numerical methods. Optical switches and filters using Silicon on Insulator (SOI) then have been designed and analyzed. This device can become a new basic component for further applications in optical signal processing. The paper concludes with some further examples of photonic signal processing circuits based on MMI couplers.
NASA Technical Reports Server (NTRS)
1983-01-01
Topics discussed include radiation effects in devices; the basic mechanisms of radiation effects in structures and materials; radiation effects in integrated circuits; spacecraft charging and space radiation effects; hardness assurance for devices and systems; and radiation transport, energy deposition and charge collection. Papers are presented on the mechanisms of small instabilities in irradiated MOS transistors, on the radiation effects on oxynitride gate dielectrics, on the discharge characteristics of a simulated solar cell array, and on latchup in CMOS devices from heavy ions. Attention is also given to proton upsets in orbit, to the modeling of single-event upset in bipolar integrated circuits, to high-resolution studies of the electrical breakdown of soil, and to a finite-difference solution of Maxwell's equations in generalized nonorthogonal coordinates.
The HelCat dual-source plasma device.
Lynn, Alan G; Gilmore, Mark; Watts, Christopher; Herrea, Janis; Kelly, Ralph; Will, Steve; Xie, Shuangwei; Yan, Lincan; Zhang, Yue
2009-10-01
The HelCat (Helicon-Cathode) device has been constructed to support a broad range of basic plasma science experiments relevant to the areas of solar physics, laboratory astrophysics, plasma nonlinear dynamics, and turbulence. These research topics require a relatively large plasma source capable of operating over a broad region of parameter space with a plasma duration up to at least several milliseconds. To achieve these parameters a novel dual-source system was developed utilizing both helicon and thermionic cathode sources. Plasma parameters of n(e) approximately 0.5-50 x 10(18) m(-3) and T(e) approximately 3-12 eV allow access to a wide range of collisionalities important to the research. The HelCat device and initial characterization of plasma behavior during dual-source operation are described.
Body Building Boons From Apollo
NASA Technical Reports Server (NTRS)
1978-01-01
The Exer-Genie program utilizes familiar types of exercise, such as isometrics (pushing or pulling against an immovable object) and isotonics (motive exercises such as calisthenics or weight lifting) but with the important added factor of controlled resistance. The device is an arrangement of hand grips and nylon cord wrapped around an aluminum shaft. Controlled friction determines the resistance and the user can set the amount of resistive force to his own physical conditioning needs. Since Apollo days, the Exer-Genie and a similar device called the Apollo Exerciser have found wide acceptance among professional, collegiate and high school athletic teams, and among the growing number of individuals interested in physical fitness. These devices are efficient and economical replacements for conventional conditioning equipment and extremely versatile, allowing more than 100 basic exercises for shaping up specific muscle groups.
Surface photovoltage measurements and finite element modeling of SAW devices.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donnelly, Christine
2012-03-01
Over the course of a Summer 2011 internship with the MEMS department of Sandia National Laboratories, work was completed on two major projects. The first and main project of the summer involved taking surface photovoltage measurements for silicon samples, and using these measurements to determine surface recombination velocities and minority carrier diffusion lengths of the materials. The SPV method was used to fill gaps in the knowledge of material parameters that had not been determined successfully by other characterization methods. The second project involved creating a 2D finite element model of a surface acoustic wave device. A basic form ofmore » the model with the expected impedance response curve was completed, and the model is ready to be further developed for analysis of MEMS photonic resonator devices.« less
Schnier, Tobias; Emara, Jennifer; Olthof, Selina; Meerholz, Klaus
2017-01-01
Hybrid organic/inorganic halide perovskites have lately been a topic of great interest in the field of solar cell applications, with the potential to achieve device efficiencies exceeding other thin film device technologies. Yet, large variations in device efficiency and basic physical properties are reported. This is due to unintentional variations during film processing, which have not been sufficiently investigated so far. We therefore conducted an extensive study of the morphology and electronic structure of a large number of CH3NH3PbI3 perovskite where we show how the preparation method as well as the mixing ratio of educts methylammonium iodide and lead(II) iodide impact properties like film formation, crystal structure, density of states, energy levels, and ultimately the solar cell performance. PMID:28287555
A rhythm-based authentication scheme for smart media devices.
Lee, Jae Dong; Jeong, Young-Sik; Park, Jong Hyuk
2014-01-01
In recent years, ubiquitous computing has been rapidly emerged in our lives and extensive studies have been conducted in a variety of areas related to smart devices, such as tablets, smartphones, smart TVs, smart refrigerators, and smart media devices, as a measure for realizing the ubiquitous computing. In particular, smartphones have significantly evolved from the traditional feature phones. Increasingly higher-end smartphone models that can perform a range of functions are now available. Smart devices have become widely popular since they provide high efficiency and great convenience for not only private daily activities but also business endeavors. Rapid advancements have been achieved in smart device technologies to improve the end users' convenience. Consequently, many people increasingly rely on smart devices to store their valuable and important data. With this increasing dependence, an important aspect that must be addressed is security issues. Leaking of private information or sensitive business data due to loss or theft of smart devices could result in exorbitant damage. To mitigate these security threats, basic embedded locking features are provided in smart devices. However, these locking features are vulnerable. In this paper, an original security-locking scheme using a rhythm-based locking system (RLS) is proposed to overcome the existing security problems of smart devices. RLS is a user-authenticated system that addresses vulnerability issues in the existing locking features and provides secure confidentiality in addition to convenience.
A Rhythm-Based Authentication Scheme for Smart Media Devices
Lee, Jae Dong; Park, Jong Hyuk
2014-01-01
In recent years, ubiquitous computing has been rapidly emerged in our lives and extensive studies have been conducted in a variety of areas related to smart devices, such as tablets, smartphones, smart TVs, smart refrigerators, and smart media devices, as a measure for realizing the ubiquitous computing. In particular, smartphones have significantly evolved from the traditional feature phones. Increasingly higher-end smartphone models that can perform a range of functions are now available. Smart devices have become widely popular since they provide high efficiency and great convenience for not only private daily activities but also business endeavors. Rapid advancements have been achieved in smart device technologies to improve the end users' convenience. Consequently, many people increasingly rely on smart devices to store their valuable and important data. With this increasing dependence, an important aspect that must be addressed is security issues. Leaking of private information or sensitive business data due to loss or theft of smart devices could result in exorbitant damage. To mitigate these security threats, basic embedded locking features are provided in smart devices. However, these locking features are vulnerable. In this paper, an original security-locking scheme using a rhythm-based locking system (RLS) is proposed to overcome the existing security problems of smart devices. RLS is a user-authenticated system that addresses vulnerability issues in the existing locking features and provides secure confidentiality in addition to convenience. PMID:25110743
Code of Federal Regulations, 2010 CFR
2010-07-01
... drinking water) or animals (including animal feeds); (B) Seeds for food crops; (C) Fertilizers or organic fertilizers; or (D) Reproductive materials (such as live animals, fertilized eggs, embryos, and semen) for the... fertilizers, live horses, western red cedar, and medical devices other than basic medical supplies, such as...
Laryngeal Support Device Enhances the Learning of Laryngeal Anatomy and Voice Physiology
ERIC Educational Resources Information Center
Curcio, Daniella Franco; Behlau, Mara; Barros, Mirna Duarte; Smith, Ricardo Luiz
2012-01-01
Multidisciplinary cooperation in health care requires a solid knowledge in the basic sciences for a common ground of communication. In speech pathology, these fundamentals improve the accuracy of descriptive diagnoses and support the development of new therapeutic techniques and strategies. The aim of this study is to briefly discuss the benefits…
Theo Jansen Project in Engineering Design Course and a Design Example
ERIC Educational Resources Information Center
Liu, Yucheng; Artigue, Aaron; Sommers, Jeremy; Chambers, Terence
2011-01-01
Objectives of a project-oriented mechanical engineering course, Engineering Design, were achieved through a design project, where students designed, built and demonstrated an extreme version of a basic Theo Jansen device. Through this project, junior students in the University of Louisiana fully developed the capability of applying mathematic and…
Turbidity threshold sampling for suspended sediment load estimation
Jack Lewis; Rand Eads
2001-01-01
Abstract - The paper discusses an automated procedure for measuring turbidity and sampling suspended sediment. The basic equipment consists of a programmable data logger, an in situ turbidimeter, a pumping sampler, and a stage-measuring device. The data logger program employs turbidity to govern sample collection during each transport event. Mounting configurations and...
Literacy as Tardis: Stories in Time and Space
ERIC Educational Resources Information Center
Davies, Julia
2017-01-01
Background/Context: This article draws on previous work about narrative, which regards the practice of storying our lives as a basic human impulse and one that draws on cultural resources to do so. Neophyte digital resources have fascinated and enticed us as devices to immerse ourselves ever deeply and widely to create shinier, polished…
Transformers and the Electric Utility System
ERIC Educational Resources Information Center
Roman, Harry T.
2005-01-01
For electric energy to get from the generating station to a home, it must pass through a transformer, a device that can change voltage levels easily. This article describes how transformers work, covering the following topics: (1) the magnetism-electricity link; (2) transformer basics; (3) the energy seesaw; (4) the turns ratio rule; and (5)…
Local Area Networks in Education: Overview, Applications, and Current Limitations.
ERIC Educational Resources Information Center
Piele, Philip K.
Local area networks (LAN) are privately owned communication systems that connect multivendor devices at high speed. As microcomputers become more common in schools, user interest in sharing information, software, and peripherals will increase. A basic understanding of the operation of all LAN's can be gained by knowing four elements: media,…
Familiarizing Students with the Basics of a Smartphone's Internal Sensors
ERIC Educational Resources Information Center
Countryman, Colleen Lanz
2014-01-01
"The Physics Teacher's" "iPhysicsLabs" column has been dedicated to the implementation of smartphones in instructional physics labs as data collection devices. In order to understand any data set, however, one should first understand how it is obtained. This concern regarding the inclusion of smartphones in lab activities…
Photogate Timing with a Smartphone
ERIC Educational Resources Information Center
Forinash, Kyle; Wisman, Raymond F.
2015-01-01
In a previous article we demonstrated that a simple, passive external circuit incorporating a thermistor, connected to a mobile device through the headset jack, can be used to collect temperature data. The basic approach is to output a sine wave signal to the headset port, through the circuit, and input the resulting signal from the headset…
Independent Living Evaluation-Training Program. Reprint Series No. 16.
ERIC Educational Resources Information Center
Van Soest, Eileen; And Others
Intended to be used both as a guide for general program direction and as an individual evaluation and training tool this rehabilitation training guide includes materials and evaluation devices for use with mentally and/or physically handicapped clients on basic, intermediate and advanced living center levels. The eight independent living skill…
Playing with Water Drops: From Wetting to Optics through Electrostatics
ERIC Educational Resources Information Center
Domps, A.; Roques-Carmes, T.
2011-01-01
We present a consistent series of activities, including experiments and basic computational studies, investigating the shape and optical properties of water drops in connection with novel technological devices. Most of the work can be carried out with simple teaching equipment and is well suited to undergraduate students. Firstly, we show how the…
40 CFR 270.310 - What equipment information must I keep at my facility?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (e.g., identify the hazardous waste management unit on a facility plot plan). (3) Type of equipment... compliance test required by 40 CFR 264.1033(j). (3) A design analysis, specifications, drawings, schematics... acceptable to the Director that present basic control device design information. The design analysis must...
Mobile Chatting Behaviour of Arts and Science College Students
ERIC Educational Resources Information Center
Ramakrishnan, N.; Priya, J. Johnsi
2016-01-01
Mobile connectivity is the order of the day. Personas irrespective of their socio-economic status possess mobile device either basic or advanced android or windows or IOS. The chat applications have become popular with younger generation. It has started trickling down to children below the age of eighteen. The behaviour has influenced the aged…
Nanoparticle Solutions for Printed Electronics
2013-09-19
the printed semiconductor materials and their nanoparticle and colloidal precursors. Without this basic knowledge, further development and the...titania, silica ) were investigated in the production of complementary inks for complex devices. These were either obtained commercially in...layers were also deposited on borosilicate glass and silicon wafers. In the photovoltaic program, hybrid inorganic-organic semiconductor combinations
Fasteners. FOS: Fundamentals of Service.
ERIC Educational Resources Information Center
John Deere Co., Moline, IL.
This manual on fasteners (devices used in home and shop to hold things together) is one of a series of power mechanics texts and visual aids on operation, diagnosis, and repair. Materials provide basic information and illustrations for use by vocational students and teachers as well as shop servicemen and laymen. Seven chapters are included: (1)…
NASA Office of Aeronautics and Space Technology Summer Workshop. Volume 10: Basic research panel
NASA Technical Reports Server (NTRS)
1975-01-01
Possible research experiments using the space transportation system are identified based on user requirements. Opportunity driven research areas include quantum electronics, cryogenics system technology, superconducting devices and detectors, and photo-induced reactions. Mission driven research requirements were examined and ranked based on inputs from the user group.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-08
... allow certain other authorized individual professional providers acting within the scope of their... Management Activity (TMA) can reimburse for the base or basic equipment or device that meet the beneficiary's... Docket Management System Office, 4800 Mark Center Drive, 2nd floor, East Tower, Suite 02G09, Alexandria...
Plastic Solar Cells: A Multidisciplinary Field to Construct Chemical Concepts from Current Research
ERIC Educational Resources Information Center
Gomez, Rafael; Segura, Jose L.
2007-01-01
Examples of plastic solar-cell technology to illustrate core concepts in chemistry are presented. The principles of operations of a plastic solar cell could be used to introduce key concepts, which are fundamentally important to understand photosynthesis and the basic process that govern most novel optoelectronic devices.
SALES PROMOTION, A SUGGESTED ADULT DISTRIBUTIVE EDUCATION COURSE OUTLINE.
ERIC Educational Resources Information Center
RUBIN, ALAN J.; AND OTHERS
THIS SUGGESTED OUTLINE FOR A BASIC COURSE IN SALES PROMOTION IS DESIGNED FOR NOT LESS THAN FIVE 2-HOUR SESSIONS ON (1) ASPECTS OF SALES PROMOTION, (2) SALES PROMOTION TECHNIQUES, (3) NEWSPAPER ADVERTISING, (4) WINDOW AND INTERIOR DISPLAY PRINCIPLES, AND (5) SELECTED PROMOTIONAL MEDIA AND DEVICES. POSSIBLE TEACHERS INCLUDE A SALES PROMOTION…
Left to Their Own Devices for Education Technology
ERIC Educational Resources Information Center
Kennedy, Mike
2012-01-01
The education system has changed dramatically over the years, but the basic process still involves teachers conveying information and insights to students. The tools and strategies that help teachers accomplish this goal have evolved, and schools are continually in search of the piece of equipment that will enable them to educate more students…
Patterns in Student Financial Aid at Rural Community Colleges
ERIC Educational Resources Information Center
Hardy, David E.; Katsinas, Stephen G.
2008-01-01
This article uses the 2005 Basic Classifications of the Carnegie Foundation for the Advancement of Teaching as a framing device through which to examine patterns of student financial aid at America's rural community colleges, which represent 64% of all U.S. community colleges. Rural community colleges serve more first-time, full-time students than…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawniczak-Jablonska, K.; Liliental-Weber, Z.; Gullikson, E.M.
1997-04-01
Group III nitrides (AlN, GaN, and InN) consist of the semiconductors which appear recently as a basic materials for optoelectronic devices active in the visible/ultraviolet spectrum as well as high-temperature and high-power microelectronic devices. However, understanding of the basic physical properties leading to application is still not satisfactory. One of the reasons consists in unsufficient knowledge of the band structure of the considered semiconductors. Several theoretical studies of III-nitrides band structure have been published but relatively few experimental studies have been carried out, particularly with respect to their conduction band structure. This motivated the authors to examine the conduction bandmore » structure projected onto p-states of the nitrogen atoms for AlN, GaN and InN. An additional advantage of their studies is the availability of the studied nitrides in two structures, hexagonal (wurtzite) and cubic (zincblende). This offers an opportunity to gain information about the role of the anisotropy of electronic band states in determining various physical properties.« less
La Barbera, Luigi; Galbusera, Fabio; Wilke, Hans-Joachim; Villa, Tomaso
2016-09-01
To discuss whether the available standard methods for preclinical evaluation of posterior spine stabilization devices can represent basic everyday life activities and how to compare the results obtained with different procedures. A comparative finite element study compared ASTM F1717 and ISO 12189 standards to validated instrumented L2-L4 segments undergoing standing, upper body flexion and extension. The internal loads on the spinal rod and the maximum stress on the implant are analysed. ISO recommended anterior support stiffness and force allow for reproducing bending moments measured in vivo on an instrumented physiological segment during upper body flexion. Despite the significance of ASTM model from an engineering point of view, the overly conservative vertebrectomy model represents an unrealistic worst case scenario. A method is proposed to determine the load to apply on assemblies with different anterior support stiffnesses to guarantee a comparable bending moment and reproduce specific everyday life activities. The study increases our awareness on the use of the current standards to achieve meaningful results easy to compare and interpret.
Prevention of Device-Related Healthcare-Associated Infections
Septimus, Edward J.; Moody, Julia
2016-01-01
Healthcare-associated infections (HAIs) are a leading cause of morbidity and mortality in hospitalized patients. Up to 15% of patients develop an infection while hospitalized in the United States, which accounts for approximately 1.7 million HAIs, 99,000 deaths annually and over 10 billion dollars in costs per year. A significant percentage of HAIs are preventable using evidenced-based strategies. In terms of device-related HAIs it is estimated that 65-70% of catheter-line associated bloodstream infections (CLABSIs) and catheter-associated urinary tract infections (CAUTIs) are preventable. To prevent CLABSIs a bundle which includes hand hygiene prior to insertion and catheter manipulation, use of chlorhexidene alcohol for site preparation and maintenance, use of maximum barrier for catheter insertion, site selection, removing nonessential lines, disinfect catheter hubs before assessing line, and dressing changes are essential elements of basic practices. To prevent CAUTIs a bundle that includes hand hygiene for insertion and catheter or bag manipulation, inserting catheters for appropriate indications, insert using aseptic technique, remove catheters when no longer needed, maintain a close system keeping bag and tubing below the bladder are the key components of basic practices. PMID:26918162
N channel JFET based digital logic gate structure
NASA Technical Reports Server (NTRS)
Krasowski, Michael J. (Inventor)
2010-01-01
A circuit topography is presented which is used to create usable digital logic gates using N (negatively doped) channel Junction Field Effect Transistors (JFETs) and load resistors, level shifting resistors, and supply rails whose values are based on the direct current (DC) parametric distributions of those JFETs. This method has direct application to the current state of the art in high temperature, for example 300.degree. C. to 500.degree. C. and higher, silicon carbide (SiC) device production. The ability to produce inverting and combinatorial logic enables the production of pulse and edge triggered latches. This scale of logic synthesis would bring digital logic and state machine capabilities to devices operating in extremely hot environments, such as the surface of Venus, near hydrothermal vents, within nuclear reactors (SiC is inherently radiation hardened), and within internal combustion engines. The basic logic gate can be configured as a driver for oscillator circuits allowing for time bases and simple digitizers for resistive or reactive sensors. The basic structure of this innovation, the inverter, can be reconfigured into various analog circuit topographies through the use of feedback structures.
Nitta, S; Yambe, T; Katahira, Y; Sonobe, T; Saijoh, Y; Naganuma, S; Akiho, H; Kakinuma, Y; Tanaka, M; Miura, M
1991-12-01
To evaluate the various basic designs of the pump chambers used in the ventricular assist devices (VADs), hydrodynamic endurance test was performed from the viewpoint of the durability of the prosthetic valves used in the VAD. For the hydrodynamic analysis, we designed three basic types of pump (sac type, diaphragm type, and pusher plate type) using the same material and having the same capacity and shape. Prosthetic valves in these VADs were tested from the standpoint of the water hammer effect, which affects the valve durability, to determine which pump design would be most durable as a prosthetic valve in the VAD. The water-hammer phenomenon was evaluated using the maximum pressure gradient (MPG) across the prosthetic valve in the moc circulatory loop. Maximum pump output was recorded when we used the diaphragm type model, and minimum MPG in the commonly used driving condition of the VAD were recorded when we used the sac type model. The results suggest that the sac type VAD model is the most durable design for the prosthetic value.
Kawaguchi, Koji; Egi, Hiroyuki; Hattori, Minoru; Sawada, Hiroyuki; Suzuki, Takahisa; Ohdan, Hideki
2014-10-01
Virtual reality surgical simulators are becoming popular as a means of providing trainees with an opportunity to practice laparoscopic skills. The Lap-X (Epona Medical, Rotterdam, the Netherlands) is a novel VR simulator for training basic skills in laparoscopic surgery. The objective of this study was to validate the LAP-X laparoscopic virtual reality simulator by assessing the face and construct validity in order to determine whether the simulator is adequate for basic skills training. The face and content validity were evaluated using a structured questionnaire. To assess the construct validity, the participants, nine expert surgeons (median age: 40 (32-45)) (>100 laparoscopic procedures) and 11 novices performed three basic laparoscopic tasks using the Lap-X. The participants reported a high level of content validity. No significant differences were found between the expert surgeons and the novices (Ps > 0.246). The performance of the expert surgeons on the three tasks was significantly better than that of the novices in all parameters (Ps < 0.05). This study demonstrated the face, content and construct validity of the Lap-X. The Lap-X holds real potential as a home and hospital training device.
Applications of asymmetric nanotextured parylene surface using its wetting and transport properties
NASA Astrophysics Data System (ADS)
Sekeroglu, Koray
In this thesis, basic digital fluidics devices were introduced using polymeric nanorods (nano-PPX) inspired from nature. Natural inspiration ignited this research by observing butterfly wings, water strider legs, rye grass leaves, and their asymmetric functions. Nano-PPX rods, manufactured by an oblique angle polymerization (OAP) method, are asymmetrically aligned structures that have unidirectional wetting properties. Nano-PPX demonstrates similar functions to the directional textured surfaces of animals and plants in terms of wetting, adhesion, and transport. The water pin-release mechanism on the asymmetric nano-PPX surface with adhesion function provides a great transport property. How the asymmetry causes transport is discussed in terms of hysteresis and interface contact of water droplets. In this study, the transport property of nano-PPX rods is used to guide droplets as well as transporting cargo such as microgels. With the addition of tracks on the nano-PPX rods, the surfaces were transformed into basic digital fluidics devices. The track-assisted nano-PPX has been employed to applications (i.e. sorting, mixing, and carrying cargo particles). Thus, digital fluidics devices fabricated on nano-PPX surface is a promising pathway to assemble microgels in the field of bioengineering. The characterization of the nano textured surface was completed using methods such as Scanning Electron Microscopy, Atomic Force Microscopy, Contact Angle Goniometry, and Fourier Transform Infra-Red Spectroscopy. These methods helped to understand the physical and chemical properties of nano-PPX. Parameters such as advancing and receding contact angles, nanorod tilt angle, and critical drop volumes were utilized to investigate the anisotropic wetting properties of nano-PPX surface. This investigation explained the directional wetting behavior of the surface as well as approaching new design parameters for adjusting surface properties. The nanorod tilt angle was a key parameter, thus changing the angle provided the surface with essential wetting properties. This adjustment on the nano-PPX surface exhibited excellent control on water droplet transport as well as guided the droplets from desired points to targets. The results demonstrated that it is possible to create railroad-like paths to manipulate the droplet movements by deforming the nano-PPX surface. Controlling physical properties of the surface granted the inspiration for fabricating basic fluidic devices to sort and mix droplets. These devices are promising for assembly purposes in terms of using microgels in engineering applications (i.e. building blocks for bioengineering). The surface has potential for further development to achieve the directed assembly of microgels into close proximity.
NASA Technical Reports Server (NTRS)
Metcalfe, A. G.; Bodenheimer, R. E.
1976-01-01
A parallel algorithm for counting the number of logic-l elements in a binary array or image developed during preliminary investigation of the Tse concept is described. The counting algorithm is implemented using a basic combinational structure. Modifications which improve the efficiency of the basic structure are also presented. A programmable Tse computer structure is proposed, along with a hardware control unit, Tse instruction set, and software program for execution of the counting algorithm. Finally, a comparison is made between the different structures in terms of their more important characteristics.
A Mobile Computing Solution for Collecting Functional Analysis Data on a Pocket PC
Jackson, James; Dixon, Mark R
2007-01-01
The present paper provides a task analysis for creating a computerized data system using a Pocket PC and Microsoft Visual Basic. With Visual Basic software and any handheld device running the Windows Moble operating system, this task analysis will allow behavior analysts to program and customize their own functional analysis data-collection system. The program will allow the user to select the type of behavior to be recorded, choose between interval and frequency data collection, and summarize data for graphing and analysis. We also provide suggestions for customizing the data-collection system for idiosyncratic research and clinical needs. PMID:17624078
NASA Astrophysics Data System (ADS)
Kim, Woo-Ju; Lee, Hak-Soon; Lee, Sang-Shin
2012-04-01
A compact silicon nitride grating coupler with flexible bandwidth was demonstrated taking advantage of a basic grating integrated with a serially connected multistage multimode interference (MMI) filter. The spectral response could be tailored by varying the order of the MMI filter, without affecting the basic grating structure. The dependence of the spectral response of the proposed device on the order of the MMI stage was thoroughly investigated. As regards the fabricated grating coupler with a four-stage MMI filter, the observed spectral bandwidth was efficiently altered from 53 to 21 nm in the ˜1550 nm spectral band.
LLL 8080 BASIC-II interpreter user's manual
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGoldrick, P.R.; Dickinson, J.; Allison, T.G.
1978-04-03
Scientists are finding increased applications for microprocessors as process controllers in their experiments. However, while microprocessors are small and inexpensive, they are difficult to program in machine or assembly language. A high-level language is needed to enable scientists to develop their own microcomputer programs for their experiments on location. Recognizing this need, LLL contracted to have such a language developed. This report describes the resulting LLL BASIC interpreter, which opeates with LLL's 8080-based MCS-8 microcomputer system. All numerical operations are done using Advanced Micro Device's Am9511 arithmetic processor chip or optionally by using a software simulation of that chip. 1more » figure.« less
Comparison of technologies for deorbiting spacecraft from low-earth-orbit at end of mission
NASA Astrophysics Data System (ADS)
Sánchez-Arriaga, G.; Sanmartín, J. R.; Lorenzini, E. C.
2017-09-01
An analytical comparison of four technologies for deorbiting spacecraft from Low-Earth-Orbit at end of mission is presented. Basic formulas based on simple physical models of key figures of merit for each device are found. Active devices - rockets and electrical thrusters - and passive technologies - drag augmentation devices and electrodynamic tethers - are considered. A basic figure of merit is the deorbit device-to-spacecraft mass ratio, which is, in general, a function of environmental variables, technology development parameters and deorbit time. For typical state-of-the-art values, equal deorbit time, middle inclination and initial altitude of 850 km, the analysis indicates that tethers are about one and two orders of magnitude lighter than active technologies and drag augmentation devices, respectively; a tether needs a few percent mass-ratio for a deorbit time of a couple of weeks. For high inclination, the performance drop of the tether system is moderate: mass ratio and deorbit time increase by factors of 2 and 4, respectively. Besides collision risk with other spacecraft and system mass considerations, such as main driving factors for deorbit space technologies, the analysis addresses other important constraints, like deorbit time, system scalability, manoeuver capability, reliability, simplicity, attitude control requirement, and re-entry and multi-mission capability (deorbit and re-boost) issues. The requirements and constraints are used to make a critical assessment of the four technologies as functions of spacecraft mass and initial orbit (altitude and inclination). Emphasis is placed on electrodynamic tethers, including the latest advances attained in the FP7/Space project BETs. The superiority of tape tethers as compared to round and multi-line tethers in terms of deorbit mission performance is highlighted, as well as the importance of an optimal geometry selection, i.e. tape length, width, and thickness, as function of spacecraft mass and initial orbit. Tether system configuration, deployment and dynamical issues, including a simple passive way to mitigate the well-known dynamical instability of electrodynamic tethers, are also discussed.
Active Management of Flap-Edge Trailing Vortices
NASA Technical Reports Server (NTRS)
Greenblatt, David; Yao, Chung-Sheng; Vey, Stefan; Paschereit, Oliver C.; Meyer, Robert
2008-01-01
The vortex hazard produced by large airliners and increasingly larger airliners entering service, combined with projected rapid increases in the demand for air transportation, is expected to act as a major impediment to increased air traffic capacity. Significant reduction in the vortex hazard is possible, however, by employing active vortex alleviation techniques that reduce the wake severity by dynamically modifying its vortex characteristics, providing that the techniques do not degrade performance or compromise safety and ride quality. With this as background, a series of experiments were performed, initially at NASA Langley Research Center and subsequently at the Berlin University of Technology in collaboration with the German Aerospace Center. The investigations demonstrated the basic mechanism for managing trailing vortices using retrofitted devices that are decoupled from conventional control surfaces. The basic premise for managing vortices advanced here is rooted in the erstwhile forgotten hypothesis of Albert Betz, as extended and verified ingeniously by Coleman duPont Donaldson and his collaborators. Using these devices, vortices may be perturbed at arbitrarily long wavelengths down to wavelengths less than a typical airliner wingspan and the oscillatory loads on the wings, and hence the vehicle, are small. Significant flexibility in the specific device has been demonstrated using local passive and active separation control as well as local circulation control via Gurney flaps. The method is now in a position to be tested in a wind tunnel with a longer test section on a scaled airliner configuration. Alternatively, the method can be tested directly in a towing tank, on a model aircraft, a light aircraft or a full-scale airliner. The authors believed that this method will have significant appeal from an industry perspective due to its retrofit potential with little to no impact on cruise (devices tucked away in the cove or retracted); low operating power requirements; small lift oscillations when deployed in a time-dependent manner; and significant flexibility with respect to the specific devices selected.
Type synthesis and preliminary design of devices supporting lower limb's rehabilitation.
Olinski, Michał; Lewandowski, Bogusz; Gronowicz, Antoni
2015-01-01
Based on the analysis of existing solutions, biomechanics of human lower limbs and anticipated applications, results of con- siderations concerning the necessary number of degrees of freedom for the designed device supporting rehabilitation of lower extremities are presented. An analysis was carried out in order to determine the innovative kinematic structure of the device, ensuring sufficient mobility and functionality while minimizing the number of degrees of freedom. With the aid of appropriate formalised meth- ods, for instance, type synthesis, a complete variety of solutions for leg joints were obtained in the form of basic and kinematic schemes, having the potential to find application in devices supporting lower limb rehabilitation. A 3D model of ankle joint module was built in Autodesk Inventor System, then imported to Adams and assembled into a moving numerical model of a mechanism. Several conducted simulations resulted in finding the required maximum stroke of the cylinders. A comparison of the angular ranges of ankle joint and similar devices with the ones achieved by the designed device indicated a sufficient reserve allowing not only movements typical of gait, but approximately achieving the passive range of motion for the ankle joint.
A review of digital microfluidics as portable platforms for lab-on a-chip applications.
Samiei, Ehsan; Tabrizian, Maryam; Hoorfar, Mina
2016-07-07
Following the development of microfluidic systems, there has been a high tendency towards developing lab-on-a-chip devices for biochemical applications. A great deal of effort has been devoted to improve and advance these devices with the goal of performing complete sets of biochemical assays on the device and possibly developing portable platforms for point of care applications. Among the different microfluidic systems used for such a purpose, digital microfluidics (DMF) shows high flexibility and capability of performing multiplex and parallel biochemical operations, and hence, has been considered as a suitable candidate for lab-on-a-chip applications. In this review, we discuss the most recent advances in the DMF platforms, and evaluate the feasibility of developing multifunctional packages for performing complete sets of processes of biochemical assays, particularly for point-of-care applications. The progress in the development of DMF systems is reviewed from eight different aspects, including device fabrication, basic fluidic operations, automation, manipulation of biological samples, advanced operations, detection, biological applications, and finally, packaging and portability of the DMF devices. Success in developing the lab-on-a-chip DMF devices will be concluded based on the advances achieved in each of these aspects.
Subramanian, Alagesan; Pan, Zhenghui; Zhang, Zhenbo; Ahmad, Imtiaz; Chen, Jing; Liu, Meinan; Cheng, Shuang; Xu, Yijun; Wu, Jun; Lei, Wei; Khan, Qasim; Zhang, Yuegang
2018-04-18
All-inorganic perovskite light-emitting diode (PeLED) has a high stability in ambient atmosphere, but it is a big challenge to achieve high performance of the device. Basically, device design, control of energy-level alignment, and reducing the energy barrier between adjacent layers in the architecture of PeLED are important factors to achieve high efficiency. In this study, we report a CsPbBr 3 -based PeLED with an inverted architecture using lithium-doped TiO 2 nanoparticles as the electron transport layer (ETL). The optimal lithium doping balances the charge carrier injection between the hole transport layer and ETL, leading to superior device performance. The device exhibits a current efficiency of 3 cd A -1 , a luminance efficiency of 2210 cd m -2 , and a low turn-on voltage of 2.3 V. The turn-on voltage is one of the lowest values among reported CsPbBr 3 -based PeLEDs. A 7-fold increase in device efficiencies has been obtained for lithium-doped TiO 2 compared to that for undoped TiO 2 -based devices.
Room-temperature ballistic transport in III-nitride heterostructures.
Matioli, Elison; Palacios, Tomás
2015-02-11
Room-temperature (RT) ballistic transport of electrons is experimentally observed and theoretically investigated in III-nitrides. This has been largely investigated at low temperatures in low band gap III-V materials due to their high electron mobilities. However, their application to RT ballistic devices is limited by their low optical phonon energies, close to KT at 300 K. In addition, the short electron mean-free-path at RT requires nanoscale devices for which surface effects are a limitation in these materials. We explore the unique properties of wide band-gap III-nitride semiconductors to demonstrate RT ballistic devices. A theoretical model is proposed to corroborate experimentally their optical phonon energy of 92 meV, which is ∼4× larger than in other III-V semiconductors. This allows RT ballistic devices operating at larger voltages and currents. An additional model is described to determine experimentally a characteristic dimension for ballistic transport of 188 nm. Another remarkable property is their short carrier depletion at device sidewalls, down to 13 nm, which allows top-down nanofabrication of very narrow ballistic devices. These results open a wealth of new systems and basic transport studies possible at RT.
Microelectromechanical Systems and Nephrology: The Next Frontier in Renal Replacement Technology
Kim, Steven; Roy, Shuvo
2013-01-01
Microelectromechanical systems (MEMS) is playing a prominent role in the development of many new and innovative biomedical devices, but remains a relatively underutilized technology in nephrology. The future landscape of clinical medicine and research will only see further expansion of MEMS based technologies in device designs and applications. The enthusiasm stems from the ability to create small-scale device features with high precision in a cost effective manner. MEMS also offers the possibility to integrate multiple components into a single device. The adoption of MEMS has the potential to revolutionize how nephrologists manage kidney disease by improving the delivery of renal replacement therapies and enhancing the monitoring of physiologic parameters. To introduce nephrologists to MEMS, this review will first define relevant terms and describe the basic processes used to fabricate MEMS devices. Next, a survey of MEMS devices being developed for various biomedical applications will be illustrated with current examples. Finally, MEMS technology specific to nephrology will be highlighted and future applications will be examined. The adoption of MEMS offers novel avenues to improve the care of kidney disease patients and assist nephrologists in clinical practice. This review will serve as an introduction for nephrologists to the exciting world of MEMS. PMID:24206604
NASA Astrophysics Data System (ADS)
Minakuchi, Shu; Tsukamoto, Haruka; Takeda, Nobuo
2009-03-01
This study proposes novel hierarchical sensing concept for detecting damages in composite structures. In the hierarchical system, numerous three-dimensionally structured sensor devices are distributed throughout the whole structural area and connected with the optical fiber network through transducing mechanisms. The distributed "sensory nerve cell" devices detect the damage, and the fiber optic "spinal cord" network gathers damage signals and transmits the information to a measuring instrument. This study began by discussing the basic concept of the hierarchical sensing system thorough comparison with existing fiber optic based systems and nerve systems in the animal kingdom. Then, in order to validate the proposed sensing concept, impact damage detection system for the composite structure was proposed. The sensor devices were developed based on Comparative Vacuum Monitoring (CVM) system and the Brillouin based distributed strain sensing was utilized to gather the damage signals from the distributed devices. Finally a verification test was conducted using prototype devices. Occurrence of barely visible impact damage was successfully detected and it was clearly indicated that the hierarchical system has better repairability, higher robustness, and wider monitorable area compared to existing systems utilizing embedded optical fiber sensors.
Numerical Simulation of Tubular Pumping Systems with Different Regulation Methods
NASA Astrophysics Data System (ADS)
Zhu, Honggeng; Zhang, Rentian; Deng, Dongsheng; Feng, Xusong; Yao, Linbi
2010-06-01
Since the flow in tubular pumping systems is basically along axial direction and passes symmetrically through the impeller, most satisfying the basic hypotheses in the design of impeller and having higher pumping system efficiency in comparison with vertical pumping system, they are being widely applied to low-head pumping engineering. In a pumping station, the fluctuation of water levels in the sump and discharge pool is most common and at most time the pumping system runs under off-design conditions. Hence, the operation of pump has to be flexibly regulated to meet the needs of flow rates, and the selection of regulation method is as important as that of pump to reduce operation cost and achieve economic operation. In this paper, the three dimensional time-averaged Navier-Stokes equations are closed by RNG κ-ɛ turbulent model, and two tubular pumping systems with different regulation methods, equipped with the same pump model but with different designed system structures, are numerically simulated respectively to predict the pumping system performances and analyze the influence of regulation device and help designers make final decision in the selection of design schemes. The computed results indicate that the pumping system with blade-adjusting device needs longer suction box, and the increased hydraulic loss will lower the pumping system efficiency in the order of 1.5%. The pumping system with permanent magnet motor, by means of variable speed regulation, obtains higher system efficiency partly for shorter suction box and partly for different structure design. Nowadays, the varied speed regulation is realized by varied frequency device, the energy consumption of which is about 3˜4% of output power of the motor. Hence, when the efficiency of variable frequency device is considered, the total pumping system efficiency will probably be lower.
Development of an ultra-portable echo device connected to USB port.
Saijo, Yoshifumi; Nitta, Shin-ichi; Kobayashi, Kazuto; Arai, Hitoshi; Nemoto, Yukiko
2004-04-01
In practical cardiology, a stethoscope based auscultation has been used to reveal the patient's clinical status. Recently, several hand-held echo devices are going on market and they are expected to play a role as "visible" auscultation instead of stethoscope. We have developed a portable and inexpensive echo device which can be used for screening of cardiac function. Two single element transducers were attached 180 degrees apart to a rotor with 14-mm diameter. The mechanical scanner, integrated circuits for transmitting and receiving ultrasonic signals and an A/D converter were encapsulated in a 150 x 40 mm probe weighing 200 g. The scan was started and the image was displayed on a Windows based personal computer (PC) as soon as the probe was connected to USB 2.0 port of the PC. The central frequency was available between 2.5 and 7.5 MHz, the image depth was 15 cm and the frame rate was 30/s. The estimated price of this ultra-portable ultrasound is about 3000 US dollars with software. For 69 cardiac patients with informed consent, image quality was compared with those obtained with basic range diagnostic echo machines. Left ventricular ejection fraction (EF) derived from normal M-mode image of standard machines (EFm) were compared with visual EF of the ultra-portable ultrasound device (EFv). The image quality was comparable to the basic range diagnostic echo machines although short axis view of aortic root was not clearly visualized because the probe was too large for intercostal approach. EFv agreed well with EFm. The ultra-portable ultrasound may provide useful information on screening and health care.
Prologue: ventricular assist devices and total artificial hearts. A historical perspective.
Frazier, O H
2003-02-01
In the 1960s, when LVADs and TAHs were introduced into clinical use, researchers estimated that, with this technology, the problem of heart failure could be solved within 20 years. Unfortunately, the evolution of these devices has taken much longer than anticipated. Nevertheless, significant advances have been achieved in both cardiac assistance and replacement, and today's cardiac surgeons have a wide range of devices from which to choose (Table 4). This progress has largely been due to the support of the NHLBI, especially the Devices and Technology Division headed by John Watson, and of the devoted commitment of the investigators. Because of the long-term commitment required for both basic and clinical research, commercial medical technology companies are unable to assume this burden. Advances in mechanical circulatory support and replacement have benefited numerous patients worldwide who would otherwise have died of heart failure, and devices now exist for use as bridges to recovery, bridges to transplant, and destination therapy. The current challenge is to refine what we have and to apply these technologies to broader patient populations with maximal safety and at a reasonable cost.
Stephens, Michael; Weber, Erica; Barrett, Steven F
2006-01-01
An assistive technology (AT) device was originally created for a young child who has difficulty communicating. The child is not able to talk and is not old enough to read yet. This rules out conventional communication devices that this child could use to communicate. A device was requested by the child's educator that would talk for the child. Originally it needed to be wristwatch size and able to visually cue the child so that the child would know what was going to be said. The project's first prototype was built by a senior design student. Although the basic features of the prototype functioned properly, it was not practical for day to day use. Originally a rebuild was requested by the educator but after further investigation it was decided that a new design was needed so that it could better cue the child. A new device was built using a high resolution graphic liquid crystal display (LCD), a voice recording chip and a microcontroller. The wristwatch size requirement was changed to meet available technology and the device was packaged to be used on a lanyard.
Brueschke, E E; Zaneveld, L J; Kaleckas, R A; Wingfield, J R
1979-05-01
Fifty-three dogs received implants of several types of flexible devices containing valving mechanisms. These devices were constructed entirely of silicone rubber with the exception of the valve stem, which was made of stainless steel. Generally, the devices were (1) implanted in the open mode and left this way for 27 to 44 months, (2) implanted in the closed mode and kept this way for 11 to 12 months before the valves were reopened, (3) implanted in either the closed or open mode and cycled to the opposite mode every 3 months (four or five cycles), or (4) implanted in either the closed or open mode and cycled to the opposite mode every 6 months (two or three cycles). Different implant methods were also evaluated. Semen analyses were regularly performed on all of the dogs, and a number of the animals were bred during the experiments. It can be concluded that (1) the devices can be opened and closed successfully over long periods, respectively allowing and preventing sperm transport; (2) the breeding ability of the animals is not impaired while the devices are in the open mode, independent of the type of device; (3) the devices do not result in an enhanced incidence of congenital abnormalities in the offspring; and (4) the success rate of device performance does not depend on the method of implanatation used. Thus, the results clearly indicate that the basic mechanism of a soft, reversible valve is a feasible approach to conception control.
Hunt, W L; Gabbay, L; Potts, M
1994-12-01
In this study the Lea's Shield was evaluated for its tolerance by women who wore the device for three consecutive days. Ten women who wore the Lea's Shield for 72 hours completed the tolerance study without adverse effects. Examination of the cervix and vagina revealed that the device did not provoke any significant cellular or microbial changes among the wearers. No major changes in the appearance or prevalence of vaginal flora occurred in the women after three days of wearing the device. A gradient in the pH could be detected between the contents of the vagina, which was more acidic than the contents of the bowl of the device. The range of cervical shapes and vaginal morphology among the study participants has had no influence upon the ability of the device to remain in its proper position. The device "settles in place" as it is pushed in, thereby obviating any special maneuvers for proper positioning. No vaginal nor cervical trauma occurred. We have concluded from these basic clinical evaluations that Lea's Shield is well tolerated during three days of use. Efficacy trials in women at risk recently completed have confirmed the high degree of acceptability and that the device can function adequately as one size fits all.
Fabrication techniques and applications of flexible graphene-based electronic devices
NASA Astrophysics Data System (ADS)
Luqi, Tao; Danyang, Wang; Song, Jiang; Ying, Liu; Qianyi, Xie; He, Tian; Ningqin, Deng; Xuefeng, Wang; Yi, Yang; Tian-Ling, Ren
2016-04-01
In recent years, flexible electronic devices have become a hot topic of scientific research. These flexible devices are the basis of flexible circuits, flexible batteries, flexible displays and electronic skins. Graphene-based materials are very promising for flexible electronic devices, due to their high mobility, high elasticity, a tunable band gap, quantum electronic transport and high mechanical strength. In this article, we review the recent progress of the fabrication process and the applications of graphene-based electronic devices, including thermal acoustic devices, thermal rectifiers, graphene-based nanogenerators, pressure sensors and graphene-based light-emitting diodes. In summary, although there are still a lot of challenges needing to be solved, graphene-based materials are very promising for various flexible device applications in the future. Project supported by the National Natural Science Foundation of China (Nos. 60936002, 61025021, 61434001, 61574083), the State Key Development Program for Basic Research of China (No. 2015CB352100), the National Key Project of Science and Technology (No. 2011ZX02403-002) and the Special Fund for Agroscientific Research in the Public Interest of China (No. 201303107). M.A.M is additionally supported by the Postdoctoral Fellowship (PDF) Program of the Natural Sciences and Engineering Research Council (NSERC) of Canada and China's Postdoctoral Science Foundation (CPSF).
Internal gas and liquid distributor for electrodeionization device
Lin, YuPo J.; Snyder, Seth W.; Henry, Michael P.; Datta, Saurav
2016-05-17
The present invention provides a resin-wafer electrodeionization (RW-EDI) apparatus including cathode and anode electrodes separated by a plurality of porous solid ion exchange resin wafers, which when in use are filled with an aqueous fluid. The apparatus includes one or more wafers comprising a basic ion exchange medium, and preferably includes one or more wafers comprising an acidic ion exchange medium. The wafers are separated from one another by ion exchange membranes. The gas and aqueous fluid are introduced into each basic wafer via a porous gas distributor which disperses the gas as micro-sized bubbles laterally throughout the distributor before entering the wafer. The fluid within the acidic and/or basic ion exchange wafers preferably includes, or is in contact with, a carbonic anhydrase (CA) enzyme or inorganic catalyst to facilitate conversion of bicarbonate ion to carbon dioxide within the acidic medium.
NASA Astrophysics Data System (ADS)
Endryansyah; Wanarti Rusimamto, Puput; Ridianto, Adam; Sugiarto, Hariyadi
2018-04-01
In the Department of Electrical Engineering FT Unesa, there are 3 majors: S1 Electrical Engineering Education, S1 Electrical Engineering, and D3 Electrical Engineering. Courses the Basic System Settings go to in the curriculum of the three programs. Team lecturer college of basic system settings seek learning innovation, focused on the development of trainer to student practicum at the laboratory of systems control. Trainer developed is a servo motor along with the lab module that contains a wide variety of theories about the servo motor and guide the practicum. This research type is development research using methods Research & development (R & D). In which the steps are applied in this study is as follows: pay attention to the potential and existing problems, gather information and study the literature, design the product, validate the design, revise the design, a limited trial. The results of the validation of learning device in the form of modules and trainer obtained as follows: score validation of learning device is 3,64; score validation lab module Servo Motor is 3,47; and questionnaire responses of students is 3,73. The result of the whole validation value is located in the interval >of 3.25 s/d 4 with the category of “Very Valid”, so it can be concluded that all instruments have a level of validity “Very Valid” and worthy of use for further learning.
Kehtari, Mousa; Zeynali, Bahman; Soleimani, Masoud; Kabiri, Mahboubeh; Seyedjafari, Ehsan
2018-04-27
Primary hepatocytes, as the gold standard cell type for in vitro models, lose their characteristic morphology and functions after few days. There is an urgent need to develop physiologically relevant models that recapitulate liver microenvironment to obtain mature hepatocyte from stem cells. We designed and fabricated a micro-bioreactor device mimicking the physiological shear stress and cell-cell interaction in liver sinusoid microenvironment. Induced pluripotent stem cells (iPSCs) were co-cultured with human umbilical vein endothelial cells (HUVECs) in the micro-bioreactor device with continuous perfusion of hepatic differentiation medium (100 μL/h). Simulation results showed that flow field inside our perfusion device was uniform and shear stress was adjusted to physiological condition (<2 dyne/cm 2 ). IPSCs-derived hepatocytes (iPSCs-Heps) that were cultured in micro-bioreactor device showed a higher level of hepatic markers compared to those in static condition. Flow cytometry and immunocytochemistry analysis revealed iPSCs cultured in the device sequentially acquired characteristics of definitive endodermal cells (SOX17 positive), hepatoblasts (AFP positive) and mature hepatocyte (ALB positive). Moreover, the albumin and urea secretion were significantly higher in micro-bioreactor device than those cultured in culture dishes during experiment. Thus, based on our results, we propose our micro-bioreactor as a beneficial device to generate mature hepatocytes for drug screening and basic research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, E.D.; Banks, W.W.; Altenbach, T.J.
1995-09-01
This report describes a preliminary application of an analysis approach for assessing relative risks in the use of radiation- emitting medical devices. Results are presented on human-initiated actions and failure modes that are most likely to occur in the use of the Gamma Knife, a gamma irradiation therapy device. This effort represents an initial step in a US Nuclear Regulatory Commission (NRC) plan to evaluate the potential role of risk analysis in regulating the use of nuclear medical devices. For this preliminary application of risk assessment, the focus was to develop a basic process using existing techniques for identifying themore » most likely risk contributors and their relative importance. The approach taken developed relative risk rankings and profiles that incorporated the type and quality of data available and could present results in an easily understood form. This work was performed by the Lawrence Livermore National Laboratory for the NRC.« less
Wang, Kai; Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao
2017-10-30
A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1-2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area.
Genchi, Giada Graziana; Marino, Attilio; Tapeinos, Christos; Ciofani, Gianni
2017-01-01
With the increasing advances in the fabrication and in monitoring approaches of nanotechnology devices, novel materials are being synthesized and tested for the interaction with biological environments. Among them, smart materials in particular provide versatile and dynamically tunable platforms for the investigation and manipulation of several biological activities with very low invasiveness in hardly accessible anatomical districts. In the following, we will briefly recall recent examples of nanotechnology-based materials that can be remotely activated and controlled through different sources of energy, such as electromagnetic fields or ultrasounds, for their relevance to both basic science investigations and translational nanomedicine. Moreover, we will introduce some examples of hybrid materials showing mutually beneficial components for the development of multifunctional devices, able to simultaneously perform duties like imaging, tissue targeting, drug delivery, and redox state control. Finally, we will highlight challenging perspectives for the development of theranostic agents (merging diagnostic and therapeutic functionalities), underlining open questions for these smart nanotechnology-based devices to be made readily available to the patients in need.
Hallbeck, M Susan; Koneczny, Sonja; Smith, Justine
2009-01-01
Controls for most technologies, including medical devices, are becoming increasingly complex, difficult to intuitively understand and don't necessarily follow population stereotypes. The resulting delays and errors are unacceptable when seconds can mean the difference between life and death. In this study participants were asked to "control" a system using a paper prototype (color photographs of controls) and then with a higher fidelity prototype of the same physical controls to determine performance differences among ethnicities and genders. No ethnic nor gender differences were found, and the comparison of paper versus higher fidelity prototypes also showed no significant differences. Thus, paper prototypes can be employed as an early device design usability tool to illustrate stereotype violations long before the first physical prototype. This will not only save money in the development and design processes, but also makes sure that even the most complex devices are intuitively understandable and operable for their basic functions.
Humidification during Mechanical Ventilation in the Adult Patient
Al Ashry, Haitham S.; Modrykamien, Ariel M.
2014-01-01
Humidification of inhaled gases has been standard of care in mechanical ventilation for a long period of time. More than a century ago, a variety of reports described important airway damage by applying dry gases during artificial ventilation. Consequently, respiratory care providers have been utilizing external humidifiers to compensate for the lack of natural humidification mechanisms when the upper airway is bypassed. Particularly, active and passive humidification devices have rapidly evolved. Sophisticated systems composed of reservoirs, wires, heating devices, and other elements have become part of our usual armamentarium in the intensive care unit. Therefore, basic knowledge of the mechanisms of action of each of these devices, as well as their advantages and disadvantages, becomes a necessity for the respiratory care and intensive care practitioner. In this paper, we review current methods of airway humidification during invasive mechanical ventilation of adult patients. We describe a variety of devices and describe the eventual applications according to specific clinical conditions. PMID:25089275
A simple device to illustrate the Einthoven triangle.
Jin, Benjamin E; Wulff, Heike; Widdicombe, Jonathan H; Zheng, Jie; Bers, Donald M; Puglisi, Jose L
2012-12-01
The Einthoven triangle is central to the field of electrocardiography, but the concept of cardiac vectors is often a difficult notion for students to grasp. To illustrate this principle, we constructed a device that recreates the conditions of an ECG reading using a battery to simulate the electrical vector of the heart and three voltmeters for the main electrocardiographic leads. Requiring minimal construction with low cost, this device provides hands-on practice that enables students to rediscover the principles of the Einthoven triangle, namely, that the direction of the cardiac dipole can be predicted from the deflections in any two leads and that lead I + lead III = lead II independent of the position of heart's electrical vector. We built a total of 6 devices for classes of 30 students and tested them in the first-year Human Physiology course at the University of California-Davis School of Medicine. Combined with traditional demonstrations with ECG machines, this equipment demonstrated its ability to help medical students obtain a solid foundation of the basic principles of electrocardiography.
Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao
2017-01-01
A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1–2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area. PMID:29084157
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jabbar, Muhandis Abdul, E-mail: muhandis.abdul@sci.ui.ac.id; Prawito
A solar cell is one of many alternative energy which is still being developed and it works by converting sunlight into electricity. In order to use a solar cell, a deep knowledge about the solar cell’s characteristics is needed. The current and voltage (I-V) produced when the light hits the solar cell surface with a certain value of intensity and at a certain value of temperature becomes the basic study to determine solar cell characteristics. In the past decade, there were so many developments of devices to characterize solar cells and solar panels. One of them used a MOSFET devicemore » for varying electronic load to observe solar cell current and voltage responses. However, many devices which have been developed even device on the market using many expensive tools and quite complex. Therefore in this research, a simple low cost electronic controlled device for solar cell characterization is built based on MOSFET method and a microcontroller but still has high reliability and accuracy.« less
Development of a new instrument for direct skin friction measurements
NASA Technical Reports Server (NTRS)
Vakili, A. D.; Wu, J. M.
1986-01-01
A device developed for the direct measurement of wall shear stress generated by flows is described. Simple and symmetric in design with optional small moving mass and no internal friction, the features employed in the design eliminate most of the difficulties associated with the traditional floating element balances. The device is basically small and can be made in various sizes. Vibration problems associated with the floating element skin friction balances were found to be minimized due to the design symmetry and optional damping provided. The design eliminates or reduces the errors associated with conventional floating element devices: such as errors due to gaps, pressure gradient, acceleration, heat transfer, and temperature change. The instrument is equipped with various sensing systems and the output signal is a linear function of the wall shear stress. Dynamic measurements could be made in a limited range and measurements in liquids could be performed readily. Measurement made in the three different tunnels show excellent agreement with data obtained by the floating element devices and other techniques.
Surgical Management of Stones: New Technology
Matlaga, Brian R.; Lingeman, James E.
2011-01-01
In recent years, the surgical treatment of kidney stone disease has undergone tremendous advances, many of which were possible only as a result of improvements in surgical technology. Rigid intracorporeal lithotrites, the mainstay of percutaneous nephrolithotomy, are now available as combination ultrasonic and ballistic devices. These combination devices have been reported to clear a stone burden with much greater efficiency than devices that operate by either ultrasonic or ballistic energy alone. The laser is the most commonly used flexible lithotrite; advances in laser lithotripsy have led to improvements in the currently utilized Holmium laser platform, as well as the development of novel laser platforms such as Thulium and Erbium devices. Our understanding of shock wave lithotripsy (SWL)has been improved over recent years as a consequence of basic science investigations. It is now recognized that there are certain maneuvers with SWL that the treating physician can do that will increase the likelihood of a successful outcome while minimizing the likelihood of adverse treatment-related events. PMID:19095207
Low-cost USB interface for operant research using Arduino and Visual Basic.
Escobar, Rogelio; Pérez-Herrera, Carlos A
2015-03-01
This note describes the design of a low-cost interface using Arduino microcontroller boards and Visual Basic programming for operant conditioning research. The board executes one program in Arduino programming language that polls the state of the inputs and generates outputs in an operant chamber. This program communicates through a USB port with another program written in Visual Basic 2010 Express Edition running on a laptop, desktop, netbook computer, or even a tablet equipped with Windows operating system. The Visual Basic program controls schedules of reinforcement and records real-time data. A single Arduino board can be used to control a total of 52 inputs/output lines, and multiple Arduino boards can be used to control multiple operant chambers. An external power supply and a series of micro relays are required to control 28-V DC devices commonly used in operant chambers. Instructions for downloading and using the programs to generate simple and concurrent schedules of reinforcement are provided. Testing suggests that the interface is reliable, accurate, and could serve as an inexpensive alternative to commercial equipment. © Society for the Experimental Analysis of Behavior.
WE-A-304-01: Strategies and Technologies for Cranial Radiosurgery Planning: MLC-Based Linac
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, G.
2015-06-15
The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Futuremore » directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.« less
WE-A-304-02: Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schlesinger, D.
2015-06-15
The high fractional doses, stringent requirements for accuracy and precision, and surgical perspective characteristic of intracranial radiosurgery create considerations for treatment planning which are distinct from most other radiotherapy procedures. This session will introduce treatment planning techniques specific to two popular intracranial SRS modalities: Gamma Knife and MLC-based Linac. The basic treatment delivery characteristics of each device will be reviewed with a focus on how those characteristics determine the paradigm used for treatment planning. Basic techniques for treatment planning will be discussed, including considerations such as isodose selection, target and organ-at-risk definition, quality indices, and protection of critical structures. Futuremore » directions for SRS treatment planning will also be discussed. Learning Objectives: Introduce the basic physical principles of intracranial radiosurgery and how they are realized in the treatment planning paradigms for Gamma Knife and Linac radiosurgery. Demonstrate basic treatment planning techniques. Discuss metrics for evaluating SRS treatment plan quality. Discuss recent and future advances in SRS treatment planning. D. Schlesinger receives research support from Elekta, AB.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swallow, E.C.
This paper discusses developments in light collection which had their origin in efforts to construct high performance gas Cerenkov detectors for precision studies of hyperon beta decays at the ZGS. The resulting devices, know generally as {open_quotes}compound parabolic concentrators,{close_quotes} have found applications ranging from nuclear and particle physics experiments to solar energy concentration, instrument illumination, and understanding the optics of visual receptors. Interest in these devices and the ideas underlying them stimulated the development of a substantial new subfield of physics: nonimaging optics. This progression provides an excellent example of some ways in which unanticipated - and often unanticipatable -more » applied science and {open_quotes}practical{close_quotes} devices naturally emerge from first-rate basic science. The characteristics of this process suggest that the term {open_quotes}spinoff{close_quotes} commonly used to denote it is misleading and in need of replacement.« less
Bioanalysis in microfluidic devices.
Khandurina, Julia; Guttman, András
2002-01-18
Microfabricated bioanalytical devices (also referred to as laboratory-on-a-chip or micro-TAS) offer highly efficient platforms for simultaneous analysis of a large number of biologically important molecules, possessing great potential for genome, proteome and metabolome studies. Development and implementation of microfluidic-based bioanalytical tools involves both established and evolving technologies, including microlithography, micromachining, micro-electromechanical systems technology and nanotechnology. This article provides an overview of the latest developments in the key device subject areas and the basic interdisciplinary technologies. Important aspects of DNA and protein analysis, interfacing issues and system integration are all thoroughly discussed, along with applications for this novel "synergized" technology in high-throughput separations of biologically important molecules. This review also gives a better understanding of how to utilize these technologies as well as to provide appropriate technical solutions to problems perceived as being more fundamental.
Navigating conflicts of interest for the medical device entrepreneur.
Donovan, Aine; Kaplan, Aaron V
2012-01-01
The past fifty years has witnessed dramatic progress in the understanding and treatment of patients suffering from cardiovascular disease leading to symptomatic relief and impressive increases in longevity. These advances have been due in large part to the development, study and implementation of new technology. Within interventional cardiology in particular, these advances have been driven by the availability of new technology in the form of medical devices. Successful device development efforts require close collaboration among basic scientist, clinician-inventors/entrepreneurs, clinician-investigators and corporations. Though the role of the clinician is central to this process, these activities present important conflicts-of-interest (COIs). The purpose of this paper is to 1) characterize these conflicts, 2) provide a context from which to approach their management and 3) recommend management strategies. Copyright © 2012 Elsevier Inc. All rights reserved.
Thin film encapsulation for flexible AM-OLED: a review
NASA Astrophysics Data System (ADS)
Park, Jin-Seong; Chae, Heeyeop; Chung, Ho Kyoon; In Lee, Sang
2011-03-01
Flexible organic light emitting diode (OLED) will be the ultimate display technology to customers and industries in the near future but the challenges are still being unveiled one by one. Thin-film encapsulation (TFE) technology is the most demanding requirement to prevent water and oxygen permeation into flexible OLED devices. As a polymer substrate does not offer the same barrier performance as glass, the TFE should be developed on both the bottom and top side of the device layers for sufficient lifetimes. This work provides a review of promising thin-film barrier technologies as well as the basic gas diffusion background. Topics include the significance of the device structure, permeation rate measurement, proposed permeation mechanism, and thin-film deposition technologies (Vitex system and atomic layer deposition (ALD)/molecular layer deposition (MLD)) for effective barrier films.
Modelling Framework and Assistive Device for Peripheral Intravenous Injections
NASA Astrophysics Data System (ADS)
Kam, Kin F.; Robinson, Martin P.; Gilbert, Mathew A.; Pelah, Adar
2016-02-01
Intravenous access for blood sampling or drug administration that requires peripheral venepuncture is perhaps the most common invasive procedure practiced in hospitals, clinics and general practice surgeries.We describe an idealised mathematical framework for modelling the dynamics of the peripheral venepuncture process. Basic assumptions of the model are confirmed through motion analysis of needle trajectories during venepuncture, taken from video recordings of a skilled practitioner injecting into a practice kit. The framework is also applied to the design and construction of a proposed device for accurate needle guidance during venepuncture administration, assessed as consistent and repeatable in application and does not lead to over puncture. The study provides insights into the ubiquitous peripheral venepuncture process and may contribute to applications in training and in the design of new devices, including for use in robotic automation.
A Detailed Historical Review of Propellant Management Devices for Low Gravity Propellant Acquisition
NASA Technical Reports Server (NTRS)
Hartwig, Jason W.
2016-01-01
This paper presents a comprehensive background and historical review of Propellant Management Devices (PMDs) used throughout spaceflight history. The purpose of a PMD is to separate liquid and gas phases within a propellant tank and to transfer vapor-free propellant from a storage tank to a transfer line en route to either an engine or receiver depot tank, in any gravitational or thermal environment. The design concept, basic flow physics, and principle of operation are presented for each type of PMD. The three primary capillary driven PMD types of vanes, sponges, and screen channel liquid acquisition devices are compared and contrasted. For each PMD type, a detailed review of previous applications using storable propellants is given, which include space experiments as well as space missions and vehicles. Examples of previous cryogenic propellant management are also presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, E. L.; Hammett, G. W.; Stoltzfus-Dueck, T.
Here, five-dimensional gyrokinetic continuum simulations of electrostatic plasma turbulence in a straight, open-field-line geometry have been performed using a full- discontinuous-Galerkin approach implemented in the Gkeyll code. While various simplifications have been used for now, such as long-wavelength approximations in the gyrokinetic Poisson equation and the Hamiltonian, these simulations include the basic elements of a fusion-device scrape-off layer: localised sources to model plasma outflow from the core, cross-field turbulent transport, parallel flow along magnetic field lines, and parallel losses at the limiter or divertor with sheath-model boundary conditions. The set of sheath-model boundary conditions used in the model allows currentsmore » to flow through the walls. In addition to details of the numerical approach, results from numerical simulations of turbulence in the Large Plasma Device, a linear device featuring straight magnetic field lines, are presented.« less
Model of Pressure Distribution in Vortex Flow Controls
NASA Astrophysics Data System (ADS)
Mielczarek, Szymon; Sawicki, Jerzy M.
2015-06-01
Vortex valves belong to the category of hydrodynamic flow controls. They are important and theoretically interesting devices, so complex from hydraulic point of view, that probably for this reason none rational concept of their operation has been proposed so far. In consequence, functioning of vortex valves is described by CFD-methods (computer-aided simulation of technical objects) or by means of simple empirical relations (using discharge coefficient or hydraulic loss coefficient). Such rational model of the considered device is proposed in the paper. It has a simple algebraic form, but is well grounded physically. The basic quantitative relationship, which describes the valve operation, i.e. dependence between the flow discharge and the circumferential pressure head, caused by the rotation, has been verified empirically. Conformity between calculated and measured parameters of the device allows for acceptation of the proposed concept.
Přibil, Jiří; Přibilová, Anna; Frollo, Ivan
2018-04-05
This article compares open-air and whole-body magnetic resonance imaging (MRI) equipment working with a weak magnetic field as regards the methods of its generation, spectral properties of mechanical vibration and acoustic noise produced by gradient coils during the scanning process, and the measured noise intensity. These devices are used for non-invasive MRI reconstruction of the human vocal tract during phonation with simultaneous speech recording. In this case, the vibration and noise have negative influence on quality of speech signal. Two basic measurement experiments were performed within the paper: mapping sound pressure levels in the MRI device vicinity and picking up vibration and noise signals in the MRI scanning area. Spectral characteristics of these signals are then analyzed statistically and compared visually and numerically.
Implementing MANETS in Android based environment using Wi-Fi direct
NASA Astrophysics Data System (ADS)
Waqas, Muhammad; Babar, Mohammad Inayatullah Khan; Zafar, Mohammad Haseeb
2015-05-01
Packet loss occurs in real-time voice transmission over wireless broadcast Ad-hoc network which creates disruptions in sound. Basic objective of this research is to design a wireless Ad-hoc network based on two Android devices by using the Wireless Fidelity (WIFI) Direct Application Programming Interface (API) and apply the Network Codec, Reed Solomon Code. The network codec is used to encode the data of a music wav file and recover the lost packets if any, packets are dropped using a loss module at the transmitter device to analyze the performance with the objective of retrieving the original file at the receiver device using the network codec. This resulted in faster transmission of the files despite dropped packets. In the end both files had the original formatted music files with complete performance analysis based on the transmission delay.
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2014 CFR
2014-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2012 CFR
2012-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2013 CFR
2013-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
40 CFR 1051.205 - What must I include in my application?
Code of Federal Regulations, 2011 CFR
2011-07-01
... emission control devices (AECDs) and all fuel-system components you will install on any production or test... specifications and other basic parameters of the vehicle's design and emission controls. List the fuel type on... scheduled maintenance you did. (g) List the specifications of the test fuel to show that it falls within the...
Mean Girls (and Boys): Cyberbullying and What Can Be Done about It
ERIC Educational Resources Information Center
Fredrick, Kathy
2009-01-01
A basic definition of "cyberbullying" is provided by Nancy Willard, director of the Center for Safe and Responsible Internet Use. She has defined cyberbullying as using the Internet or other mobile devices to send or post harmful or cruel text or images to bully others. The advent of social networking has highlighted cyberbullying. Library media…
South Carolina Word List, Grades 1-12. Basic Skills Assessment Program.
ERIC Educational Resources Information Center
Instructional Objectives Exchange, Los Angeles, CA.
Designed as a resource for reading teachers who are attempting to enhance their students' fundamental reading skills and to permit the more rigorous determination of readability levels for both instructional materials and testing devices, this word list provides a grade-by-grade set of key words students need to master for grades 1 through 12 The…
High Power High Efficiency Ka-Band Power Combiners for Solid-State Devices
NASA Technical Reports Server (NTRS)
Freeman, Jon C.; Wintucky, Edwin G.; Chevalier, Christine T.
2006-01-01
Wide-band power combining units for Ka-band are simulated for use as MMIC amplifier applications. Short-slot couplers as well as magic-tees are the basic elements for the combiners. Wide bandwidth (5 GHz) and low insertion (approx.0.2 dB) and high combining efficiencies (approx.90 percent) are obtained.
Physical Student-Robot Interaction with the ETHZ Haptic Paddle
ERIC Educational Resources Information Center
Gassert, R.; Metzger, J.; Leuenberger, K.; Popp, W. L.; Tucker, M. R.; Vigaru, B.; Zimmermann, R.; Lambercy, O.
2013-01-01
Haptic paddles--low-cost one-degree-of-freedom force feedback devices--have been used with great success at several universities throughout the US to teach the basic concepts of dynamic systems and physical human-robot interaction (pHRI) to students. The ETHZ haptic paddle was developed for a new pHRI course offered in the undergraduate…
Evaluating QR Code Case Studies Using a Mobile Learning Framework
ERIC Educational Resources Information Center
Rikala, Jenni
2014-01-01
The aim of this study was to evaluate the feasibility of Quick Response (QR) codes and mobile devices in the context of Finnish basic education. The feasibility was analyzed through a mobile learning framework, which includes the core characteristics of mobile learning. The study is part of a larger research where the aim is to develop a…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gress, A.V. Jr.
1985-08-21
At the investigation of Sandia Albuquerque, a semiautomatic powder loader was designed and fabricated for pyrotechnics devices. The basic functions of the system were to load a precise, measured amount of powder into a charge holder and to compact the mixture to a specified density. This report documents the history, rationale, design, and performance of the Mod 1 loader.
A Dual-Range Strain Gage Weighing Transducer Employing Automatic Switching
Rodger A. Arola
1968-01-01
Describes a dual-range strain gage transducer which has proven to be an excellent weight-sensing device for weighing trees and tree-length logs; discusses basic principals of the design and operation; and shows that a single transducer having two sensitivity ranges with automatic internal switching can sense weight with good repeatability and that one calibration curve...
Creating a Mobile Library Website
ERIC Educational Resources Information Center
Cutshall, Tom C.; Blake, Lindsay; Bandy, Sandra L.
2011-01-01
The overwhelming results were iPhones and Android devices. Since the library wasn't equipped technologically to develop an in-house application platform and because we wanted the content to work across all mobile platforms, we decided to focus on creating a mobile web-based platform. From the NLM page of mobile sites we chose the basic PubMed/…
Code of Federal Regulations, 2010 CFR
2010-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and design...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control... Performance Tests, Performance Evaluations, and Design Evaluations for New and Existing Sources Using Add-On Control Devices As required in § 63.5850 you must conduct performance tests, performance evaluations, and...