NASA Astrophysics Data System (ADS)
Zounemat-Kermani, Mohammad
2012-08-01
In this study, the ability of two models of multi linear regression (MLR) and Levenberg-Marquardt (LM) feed-forward neural network was examined to estimate the hourly dew point temperature. Dew point temperature is the temperature at which water vapor in the air condenses into liquid. This temperature can be useful in estimating meteorological variables such as fog, rain, snow, dew, and evapotranspiration and in investigating agronomical issues as stomatal closure in plants. The availability of hourly records of climatic data (air temperature, relative humidity and pressure) which could be used to predict dew point temperature initiated the practice of modeling. Additionally, the wind vector (wind speed magnitude and direction) and conceptual input of weather condition were employed as other input variables. The three quantitative standard statistical performance evaluation measures, i.e. the root mean squared error, mean absolute error, and absolute logarithmic Nash-Sutcliffe efficiency coefficient ( {| {{{Log}}({{NS}})} |} ) were employed to evaluate the performances of the developed models. The results showed that applying wind vector and weather condition as input vectors along with meteorological variables could slightly increase the ANN and MLR predictive accuracy. The results also revealed that LM-NN was superior to MLR model and the best performance was obtained by considering all potential input variables in terms of different evaluation criteria.
High Response Dew Point Measurement System for a Supersonic Wind Tunnel
NASA Technical Reports Server (NTRS)
Blumenthal, Philip Z.
1996-01-01
A new high response on-line measurement system has been developed to continuously display and record the air stream dew point in the NASA Lewis 10 x 10 supersonic wind tunnel. Previous instruments suffered from such problems as very slow response, erratic readings, and high susceptibility to contamination. The system operates over the entire pressure level range of the 10 x 10 SWT, from less than 2 psia to 45 psia, without the need for a vacuum pump to provide sample flow. The system speeds up tunnel testing, provides large savings in tunnel power costs and provides the dew point input for the data-reduction subroutines which calculate test section conditions.
Estimation of dew point temperature using neuro-fuzzy and neural network techniques
NASA Astrophysics Data System (ADS)
Kisi, Ozgur; Kim, Sungwon; Shiri, Jalal
2013-11-01
This study investigates the ability of two different artificial neural network (ANN) models, generalized regression neural networks model (GRNNM) and Kohonen self-organizing feature maps neural networks model (KSOFM), and two different adaptive neural fuzzy inference system (ANFIS) models, ANFIS model with sub-clustering identification (ANFIS-SC) and ANFIS model with grid partitioning identification (ANFIS-GP), for estimating daily dew point temperature. The climatic data that consisted of 8 years of daily records of air temperature, sunshine hours, wind speed, saturation vapor pressure, relative humidity, and dew point temperature from three weather stations, Daego, Pohang, and Ulsan, in South Korea were used in the study. The estimates of ANN and ANFIS models were compared according to the three different statistics, root mean square errors, mean absolute errors, and determination coefficient. Comparison results revealed that the ANFIS-SC, ANFIS-GP, and GRNNM models showed almost the same accuracy and they performed better than the KSOFM model. Results also indicated that the sunshine hours, wind speed, and saturation vapor pressure have little effect on dew point temperature. It was found that the dew point temperature could be successfully estimated by using T mean and R H variables.
Air Modeling - Observational Meteorological Data
Observed meteorological data for use in air quality modeling consist of physical parameters that are measured directly by instrumentation, and include temperature, dew point, wind direction, wind speed, cloud cover, cloud layer(s), ceiling height,
NASA Astrophysics Data System (ADS)
Matsumoto, Shigeaki; Toyooka, Satoru; Hoshino, Mitsuo
2002-09-01
In order to measure the total mass per unit area of dew droplets deposited on a metal plate in the dew-point hygrometer, the shape of a dew droplet deposited on a copper plate was measured accurately by using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an usual interference microscope. A simple method that uses a conventional speaker horn and an optical fiber cable was introduced to depress speckle noise. The shape of a dew droplet deposited on the copper plate surface with 0.1 μm in average roughness was measured with an accuracy of +/-3nm. The mass of a dew droplet could be calculated numerically from the volume of its shape and was of the order of 10-9 g. The total mass of dew droplets deposited per unit area and the deposition velocity were obtained under a gentle wind. The total mass was the order of 10-5 g/cm2 at the beginning of deposition and the deposition velocity was ranged from 2x10-6 to 6x10-5 g/cm2.min.
NASA Astrophysics Data System (ADS)
Shigeaki, Matsumoto
2003-12-01
The shape of a dew droplet deposited on the mirror surface of a copper plate was measured accurately using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an interference microscope. A simple method that uses a conventional speaker horn and an optical fibre cable was used to depress any speckle noise. The shape of a dew droplet deposited at dew point on the plate surface with average roughness of 0.1 µm was measured with an accuracy of ± 3 nm. The mass of a tiny dew droplet could be determined from the volume of its shape and was of the order of 10-9 g. The total mass of a dew droplet deposited per unit area and the deposition velocity under a gentle wind were also obtained in a similar way. The total mass was of the order of 10-5 g cm-2 at the beginning of deposition and the deposition velocity ranged from 1 × 10-5 to 6 × 10-5 g cm-2 min-1 at room temperature.
Atmospheric Science Data Center
2015-11-25
... Hot-Wire MCRW Refractometer Platinum Resistance Pressure Transducer RT-4 Pyranometer Pyrgeometer Radiometer Wind ... Parameters: Dew/Frost Point Temperature Liquid Water Content Humidity Temperature Pressure Irradiance ...
NASA Astrophysics Data System (ADS)
Kwon, Su-Yong; Kim, Jong-Chul; Choi, Byung-Il
2007-10-01
Distinguishing between a supercooled dew and frost below 0 °C in dew/frost-point measurements is an important and challenging problem that has not yet been completely solved. This study presents a new method for the recognition of a supercooled dew in a dew/frost-point sensor. A quartz crystal microbalance (QCM) sensor was used as a dew/frost-point sensor to detect a dew and a supercooled dew as well as frost. The slip phenomenon occurring at an interface between the water droplet and the surface of the quartz crystal resonator of the QCM sensor gives a simple and accurate way of distinguishing between a supercooled dew and frost below 0 °C. This method can give a highly accurate measurement of the dew or the frost point without misreading in the dew-point sensor at temperatures below 0 °C.
NASA Astrophysics Data System (ADS)
Matsumoto, Shigeaki; Toyooka, Satoru
1995-01-01
A rough-surface-type automatic dew-point hygrometer was developed using a laser diode and an optical fiber cable. A gold plate with 0.8 µ m average surface roughness was used as a surface for deposition of dew to facilitate dew deposition and prevent supersaturation of water vapor at the dew point. It was shown experimentally that the quantity of dew deposited can be controlled to be constant at any predetermined level, and is independent of the dew point to be measured. The dew points were measured in the range from -15° C to 54° C in which the temperature ranged from 0° C to 60° C. The measurement error of the dew point was ±0.5° C which was equal to below ±2% in relative humidity in the above dew-point range.
Experimental study of influence characteristics of flue gas fly ash on acid dew point
NASA Astrophysics Data System (ADS)
Song, Jinhui; Li, Jiahu; Wang, Shuai; Yuan, Hui; Ren, Zhongqiang
2017-12-01
The long-term operation experience of a large number of utility boilers shows that the measured value of acid dew point is generally lower than estimated value. This is because the influence of CaO and MgO on acid dew point in flue gas fly ash is not considered in the estimation formula of acid dew point. On the basis of previous studies, the experimental device for acid dew point measurement was designed and constructed, and the acid dew point under different smoke conditions was measured. The results show that the CaO and MgO in the flue gas fly ash have an obvious influence on the acid dew point, and the content of the fly ash is negatively correlated with the temperature of acid dew point At the same time, the concentration of H2SO4 in flue gas is different, and the acid dew point of flue gas is different, and positively correlated with the acid dew point.
47 CFR 87.525 - Scope of service.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Automatic Weather Stations (AWOS/ASOS) § 87.525 Scope of service. Automatic weather observation stations (AWOS) and automatic surface observation stations (ASOS) must provide up-to-date weather information including the time of the latest weather sequence, altimeter setting, wind speed and direction, dew point...
47 CFR 87.525 - Scope of service.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Automatic Weather Stations (AWOS/ASOS) § 87.525 Scope of service. Automatic weather observation stations (AWOS) and automatic surface observation stations (ASOS) must provide up-to-date weather information including the time of the latest weather sequence, altimeter setting, wind speed and direction, dew point...
47 CFR 87.525 - Scope of service.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Automatic Weather Stations (AWOS/ASOS) § 87.525 Scope of service. Automatic weather observation stations (AWOS) and automatic surface observation stations (ASOS) must provide up-to-date weather information including the time of the latest weather sequence, altimeter setting, wind speed and direction, dew point...
47 CFR 87.525 - Scope of service.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Automatic Weather Stations (AWOS/ASOS) § 87.525 Scope of service. Automatic weather observation stations (AWOS) and automatic surface observation stations (ASOS) must provide up-to-date weather information including the time of the latest weather sequence, altimeter setting, wind speed and direction, dew point...
47 CFR 87.525 - Scope of service.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Automatic Weather Stations (AWOS/ASOS) § 87.525 Scope of service. Automatic weather observation stations (AWOS) and automatic surface observation stations (ASOS) must provide up-to-date weather information including the time of the latest weather sequence, altimeter setting, wind speed and direction, dew point...
Project Fog Drops. Part 1: Investigations of warm fog properties
NASA Technical Reports Server (NTRS)
Pilie, R. J.; Eadie, W.; Mack, E. J.; Rogers, C.; Kocmond, W. C.
1972-01-01
A detailed study was made of the micrometeorological and microphysical characteristics of eleven valley fogs occurring near Elmira, New York. Observations were made of temperature, dew point, wind speed and direction, dew deposition, vertical wind velocity, and net radiative flux. In fog, visibility was continuously recorded and periodic measurements were made of liquid water content and drop-size distribution. The observations were initiated in late evening and continued until the time of fog dissipation. The vertical distribution of temperature in the lowest 300 meters and cloud nucleus concentration at several heights were measured from an aircraft before fog nucleus concentrations at several heights were measured from an aircraft before fog formation. A numerical model was developed to investigate the life cycle of radiation fogs. The model predicts the temporal evolution of the vertical distributions of temperature, water vapor, and liquid water as determined by the turbulent transfer of heat and moisture. The model includes the nocturnal cooling of the earth's surface, dew formation, fog drop sedimentation, and the absorption of infrared radiation by fog.
NASA Astrophysics Data System (ADS)
Amora Jofipasi, Chesilia; Miftahuddin; Hizir
2018-05-01
Weather is a phenomenon that occurs in certain areas that indicate a change in natural activity. Weather can be predicted using data in previous periods over a period. The purpose of this study is to get the best ETS model to predict the weather in Aceh Besar. The ETS model is a time series univariate forecasting method; its use focuses on trend and seasonal components. The data used are air temperature, dew point, sea level pressure, station pressure, visibility, wind speed, and sea surface temperature from January 2006 to December 2016. Based on AIC, AICc and BIC the smallest values obtained the conclusion that the ETS (M, N, A) is used to predict air temperature, and sea surface temperature, ETS (A, N, A) is used to predict dew point, sea level pressure and station pressure, ETS (A, A, N) is used to predict visibility, and ETS (A, N, N) is used to predict wind speed.
The thermodynamic and dynamical features of double front structures during 21 31 July 1998 in China
NASA Astrophysics Data System (ADS)
Zhou, Yushu; Deng, Guo; Lei, Ting; Ju, Jianhua
2005-11-01
The daily 1° × 1° data of the Aviation (AVN) model, the black body temperature (TBB) data of cloud top, and cloud images by geostationary meteorological satellite (GMS) are used to identify a dew-point front near the periphery of the western Pacific subtropical high (WPSH). The results clearly demonstrate the existence of the dew-point front, and its thermodynamic and dynamic structural characteristics are analyzed in detail. The dew-point front is a transitional belt between the moist southwest monsoon flow and the dry adiabatic sinking flow near the WPSH, manifested by a large horizontal moisture gradient in the mid-lower troposphere and conjugated with the mei-yu front to form a predominant double-front structure associated with intense rainfall in the mei-yu period. The mei-yu front is located between 30° and 35°N, vertically extends from the ground level to the upper level and shifts northward. The dew-point front is to the south of the mei-yu front and lies up against the periphery of the WPSH. Generally, it is located between 850 hPa and 500 hPa. On the dew-point front side, the southwesterly prevails at the lower level and the northeasterly at the upper level; this wind distribution is different from that on the mei-yu front side. Vertical ascending motion exists between the two fronts, and there are descending motions on the north side of the mei-yu front and on the south side of the dew-point front, which form a secondary circulation. The dynamics of the double fronts also have some interesting features. At the lower level, positive vertical vorticity and obvious convergence between the two fronts are clearly identified. At the mid-lower level, negative local change of the divergence (corresponding to increasing convergence) is often embedded in the two fronts or against the mei-yu front. Most cloud clusters occur between the two fronts and propagate down stream in a wave-like manner.
Dozier, W A; Lott, B D; Branton, S L
2005-06-01
This study examined live performance responses of male broilers to increasing air velocity of 120 and 180 m/min reared under high cyclic temperatures (25-35-25 degrees C) with a 23 degrees C dew point from 21 to 49 d. Birds were reared in an environmental facility containing 2 wind tunnels (4 pens/tunnel) and 6 floor pens (control). At 21 d, 53 birds were placed in each pen of the wind tunnels and control group, respectively, and growth performance was determined weekly. Increasing air velocity from 120 to 180 m/min improved BW and BW gain from 29 to 35, 36 to 42, and 43 to 49 d of age leading to a cumulative advantage of 287 g in BW gain and a 10-point difference in feed conversion from 21 to 49 d of age. Subjecting birds to air velocity improved growth rate, feed consumption, and feed conversion at each weekly interval from 28 to 49 d over the control birds. These results indicate that male broilers approximating 2.0 to 3.0 kg respond to an air velocity of 180 m/min when exposed to high cyclic temperatures.
Experiment Comparison between Engineering Acid Dew Point and Thermodynamic Acid Dew Point
NASA Astrophysics Data System (ADS)
Song, Jinghui; Yuan, Hui; Deng, Jianhua
2018-06-01
in order to realize the accurate prediction of acid dew point, a set of measurement system of acid dew point for the flue gas flue gas in the tail of the boiler was designed and built, And measured at the outlet of an air preheater of a power plant of 1 000 MW, The results show that: Under the same conditions, with the test temperature decreases, Nu of heat transfer tubes, fouling and corrosion of pipe wall and corrosion pieces gradually deepened. Then, the measured acid dew point is compared with the acid dew point obtained by using the existing empirical formula under the same coal type. The dew point of engineering acid is usually about 40 ° lower than the dew point of thermodynamic acid because of the coupling effect of fouling on the acid liquid, which can better reflect the actual operation of flue gas in engineering and has certain theoretical guidance for the design and operation of deep waste heat utilization system significance.
Frequency of urban building fires as related to daily weather conditions
Arthur R. Pirsko; Wallace L. Fons
1956-01-01
Daily weather elements of precipitation, wind, mean temperature, relative humidity, and dew-point temperature for selected urban areas (approximately 850,000 population) in the United States are statistically analyzed to determine their correlation with daily number of building fires. The frequency of urban building fires is found to be significantly correlated with...
An Examination of a Simulated Microburst Flow as Sensed by a Single Doppler Radar
1988-01-01
34 macrobursts " and "microbursts" dependent upon whether the downburst diameter was larger or smaller than 4 km. Although his theories initally met some...variables, unlike a macroburst which is accompanied by a dome of high pressure, gusty winds, and abruptly cooler temperatures. Ambient and dew- point
Parametric analysis of parameters for electrical-load forecasting using artificial neural networks
NASA Astrophysics Data System (ADS)
Gerber, William J.; Gonzalez, Avelino J.; Georgiopoulos, Michael
1997-04-01
Accurate total system electrical load forecasting is a necessary part of resource management for power generation companies. The better the hourly load forecast, the more closely the power generation assets of the company can be configured to minimize the cost. Automating this process is a profitable goal and neural networks should provide an excellent means of doing the automation. However, prior to developing such a system, the optimal set of input parameters must be determined. The approach of this research was to determine what those inputs should be through a parametric study of potentially good inputs. Input parameters tested were ambient temperature, total electrical load, the day of the week, humidity, dew point temperature, daylight savings time, length of daylight, season, forecast light index and forecast wind velocity. For testing, a limited number of temperatures and total electrical loads were used as a basic reference input parameter set. Most parameters showed some forecasting improvement when added individually to the basic parameter set. Significantly, major improvements were exhibited with the day of the week, dew point temperatures, additional temperatures and loads, forecast light index and forecast wind velocity.
Using regression analysis to predict emergency patient volume at the Indianapolis 500 mile race.
Bowdish, G E; Cordell, W H; Bock, H C; Vukov, L F
1992-10-01
Emergency physicians often plan and provide on-site medical care for mass gatherings. Most of the mass gathering literature is descriptive. Only a few studies have looked at factors such as crowd size, event characteristics, or weather in predicting numbers and types of patients at mass gatherings. We used regression analysis to relate patient volume on Race Day at the Indianapolis Motor Speedway to weather conditions and race characteristics. Race Day weather data for the years 1983 to 1989 were obtained from the National Oceanic and Atmospheric Administration. Data regarding patients treated on 1983 to 1989 Race Days were obtained from the facility hospital (Hannah Emergency Medical Center) data base. Regression analysis was performed using weather factors and race characteristics as independent variables and number of patients seen as the dependent variable. Data from 1990 were used to test the validity of the model. There was a significant relationship between dew point (which is calculated from temperature and humidity) and patient load (P less than .01). Dew point, however, failed to predict patient load during the 1990 race. No relationships could be established between humidity, sunshine, wind, or race characteristics and number of patients. Although higher dew point was associated with higher patient load during the 1983 to 1989 races, dew point was a poor predictor of patient load during the 1990 race. Regression analysis may be useful in identifying relationships between event characteristics and patient load but is probably inadequate to explain the complexities of crowd behavior and too simplified to use as a prediction tool.
Correlation of spring spore concentrations and meteorological conditions in Tulsa, Oklahoma
NASA Astrophysics Data System (ADS)
Troutt, C.; Levetin, E.
Different spore types are abundant in the atmosphere depending on the weather conditions. Ascospores generally follow precipitation, while spore types such as Alternaria and Cladosporium are abundant in dry conditions. This project attempted to correlate fungal spore concentrations with meteorological data from Tulsa, Oklahoma during May 1998 and May 1999. Air samples were collected and analyzed by the 12-traverse method. The spore types included were Cladosporium, Alternaria, Epicoccum, Curvularia, Pithomyces, Drechslera, smut spores, ascospores, basidiospores, and other spores. Weather variables included precipitation levels, temperature, dew point, air pressure, wind speed, wind direction and wind gusts. There were over 242.57 mm of rainfall in May 1999 and only 64.01 mm in May 1998. The most abundant spore types during May 1998 and May 1999 were Cladosporium, ascospores, and basidiospores. Results showed that there were significant differences in the dry-air spora between May 1998 and May 1999. There were twice as many Cladosporium in May 1998 as in May 1999; both ascospores and basidiospores showed little change. Multiple regression analysis was used to determine which meteorological variables influenced spore concentrations. Results showed that there was no single model for all spore types. Different combinations of factors were predictors of concentration for the various fungi examined; however, temperature and dew point seemed to be the most important meteorological factors.
Comparison of dew point temperature estimation methods in Southwestern Georgia
Marcus D. Williams; Scott L. Goodrick; Andrew Grundstein; Marshall Shepherd
2015-01-01
Recent upward trends in acres irrigated have been linked to increasing near-surface moisture. Unfortunately, stations with dew point data for monitoring near-surface moisture are sparse. Thus, models that estimate dew points from more readily observed data sources are useful. Daily average dew temperatures were estimated and evaluated at 14 stations in...
Trends in temperature and dew point at the summit of Mount Washington, New Hampshire, 1935-2004.
NASA Astrophysics Data System (ADS)
Grant, A. N.; Pszenny, A. A.; Fischer, E. V.
2005-05-01
Dry and wet bulb temperatures from sling psychrometer measurements taken every six hours from 1935 to 2004 at the summit of Mount Washington, located at 44 °16'N, 71 °18'W, 1914 m ASL have recently been digitized. Annual temperature has increased by 0.3°C, and annual dew point has decreased by 0.4°C over this 70-year period. Synoptic temperature has increased most in spring and winter, changing by 1.0°C and 0.5°C, respectively, while it has decreased slightly in summer and fall. Dew point has decreased in fall, summer, and winter, 0.9°C, 0.5°C, and 0.4°C respectively, and increased by 0.1°C in spring. Preliminary analysis suggests that some of the larger trends in winter and spring may be statistically significant; results of Monte Carlo simulations will be reported. Changes in dew point may be attributed to two factors. Decreasing dew points are expected if the temperature increases but the amount of water vapor present stays the same. Alternatively, lower dew points could be indicative of the presence of drier air. Other dew point climatologies of the continental United States for the second half of the century have shown mixed results, with increased dew points evident at some stations, decreased dew points at others, and no clear regional patterns.
Water Resources Data for Illinois - Water Year 2005 (Includes Historical Data)
LaTour, J.K.; Weldon, E.A.; Dupre, D.H.; Halfar, T.M.
2006-01-01
This annual Water-Data Report for Illinois contains current water year (Oct. 1, 2004, to Sept. 30, 2005) and historical data of discharge, stage, water quality and biology of streams; stage of lakes and reservoirs; levels and quality of ground water; and records of precipitation, air temperature, dew point, solar radiation, and wind speed. The current year's (2005) data provided in this report include (1) discharge for 182 surface-water gaging stations and for 9 crest-stage partial-record stations; (2) stage for 33 surface-water gaging stations; (3) water-quality records for 10 surface-water stations; (4) sediment-discharge records for 14 surface-water stations; (5) water-level records for 98 ground-water wells; (6) water-quality records for 17 ground-water wells; (7) precipitation records for 48 rain gages; (8) records of air temperature, dew point, solar radiation and wind speed for 1 meteorological station; and (9) biological records for 6 sample sites. Also included are miscellaneous data collected at various sites not in the systematic data-collection network. Data were collected and compiled as a part of the National Water Information System (NWIS) maintained by the U.S. Geological Survey in cooperation with Federal, State, and local agencies.
Matsumoto, S; Kobayashi, H
1979-10-15
It is necessary to distinguish between the dew point and the frost point below 0 degrees C. The freezing of the dew and the melting of the frost are respectively detected by the rapid decrease and the increase of the conduction current on the narrow surface of insulated layer made of epoxy, 0.5 mm in width and 10 mm in length, on which the dew deposits. The dew point -9 degrees C and the frost point -8 degrees C in the humidity 21% at the temperature 13 degrees C are clearly distinguished in this method.
BOREAS AES Campbell Scientific Surface Meteorological Data
NASA Technical Reports Server (NTRS)
Atkinson, G. Barrie; Funk, Barrie; Knapp. David E. (Editor); Hall, Forrest G. (Editor)
2000-01-01
Canadian AES personnel collected data related to surface and atmospheric meteorological conditions over the BOREAS region. This data set contains 15-minute meteorological data from 14 automated meteorology stations located across the BOREAS region. Included in this data are parameters of date, time, mean sea level pressure, station pressure, temperature, dew point, wind speed, resultant wind speed, resultant wind direction, peak wind, precipitation, maximum temperature in the last hour, minimum temperature in the last hour, pressure tendency, liquid precipitation in the last hour, relative humidity, precipitation from a weighing gauge, and snow depth. Temporally, the data cover the period of August 1993 to December 1996. The data are provided in tabular ASCII files, and are classified as AFM-Staff data.
NASA Astrophysics Data System (ADS)
Mitter, H.; Böse, N.; Benyon, R.; Vicente, T.
2012-09-01
During calibration of precision optical dew-point hygrometers (DPHs), it is usually necessary to take into account the pressure drop induced by the gas flow between the "point of reference" and the "point of use" (mirror or measuring head of the DPH) either as a correction of the reference dew-point temperature or as part of the uncertainty estimation. At dew-point temperatures in the range of ambient temperature and below, it is sufficient to determine the pressure drop for the required gas flow, and to keep the volumetric flow constant during the measurements. In this case, it is feasible to keep the dry-gas flow into the dew-point generator constant or to measure the flow downstream the DPH at ambient temperature. In normal operation, at least one DPH in addition to the monitoring DPH are used, and this operation has to be applied to each instrument. The situation is different at high dew-point temperatures up to 95 °C, the currently achievable upper limit reported in this paper. With increasing dew-point temperatures, the reference gas contains increasing amounts of water vapour and a constant dry-gas flow will lead to a significant enhanced volume flow at the conditions at the point of use, and therefore, to a significantly varying pressure drop depending on the applied dew-point temperature. At dew-point temperatures above ambient temperature, it is also necessary to heat the reference gas and the mirror head of the DPH sufficiently to avoid condensation which will additionally increase the volume flow and the pressure drop. In this paper, a method is provided to calculate the dry-gas flow rate needed to maintain a known wet-gas flow rate through a chilled mirror for a range of temperature and pressures.
Removal mechanisms of dew via self-propulsion off the gecko skin
Watson, Gregory S.; Schwarzkopf, Lin; Cribb, Bronwen W.; Myhra, Sverre; Gellender, Marty; Watson, Jolanta A.
2015-01-01
Condensation resulting in the formation of water films or droplets is an unavoidable process on the cuticle or skin of many organisms. This process generally occurs under humid conditions when the temperature drops below the dew point. In this study, we have investigated dew conditions on the skin of the gecko Lucasium steindachneri. When condensation occurs, we show that small dew drops, as opposed to a thin film, form on the lizard's scales. As the droplets grow in size and merge, they can undergo self-propulsion off the skin and in the process can be carried away a sufficient distance to freely engage with external forces. We show that factors such as gravity, wind and fog provide mechanisms to remove these small droplets off the gecko skin surface. The formation of small droplets and subsequent removal from the skin may aid in reducing microbial contact (e.g. bacteria, fungi) and limit conducive growth conditions under humid environments. As well as providing an inhospitable microclimate for microorganisms, the formation and removal of small droplets may also potentially aid in other areas such as reduction and cleaning of some surface contaminants consisting of single or multiple aggregates of particles. PMID:25762647
A Quartz Crystal Microbalance dew point sensor without frequency measurement.
Wang, Guohua; Zhang, Weishuo; Wang, Shuo; Sun, Jinglin
2014-11-01
This work deals with the design of a dew point sensor based on Quartz Crystal Microbalance (QCM) without measuring the frequency. This idea is inspired by the fact that the Colpitts oscillation circuit will stop oscillating when the QCM works in the liquid media. The quartz crystal and the electrode are designed through the finite element simulation and the stop oscillating experiment is conducted to verify the sensibility. Moreover, the measurement result is calibrated to approach the true value. At last a series of dew points at the same temperature is measured with the designed sensor. Results show that the designed dew point sensor is able to detect the dew point with the proper accuracy.
A quartz crystal microbalance dew point sensor without frequency measurement
NASA Astrophysics Data System (ADS)
Wang, Guohua; Zhang, Weishuo; Wang, Shuo; Sun, Jinglin
2014-11-01
This work deals with the design of a dew point sensor based on Quartz Crystal Microbalance (QCM) without measuring the frequency. This idea is inspired by the fact that the Colpitts oscillation circuit will stop oscillating when the QCM works in the liquid media. The quartz crystal and the electrode are designed through the finite element simulation and the stop oscillating experiment is conducted to verify the sensibility. Moreover, the measurement result is calibrated to approach the true value. At last a series of dew points at the same temperature is measured with the designed sensor. Results show that the designed dew point sensor is able to detect the dew point with the proper accuracy.
Raithel, C.J.; Ginsberg, H.S.; Prospero, M.L.
2006-01-01
The endangered American burying beetle, Nicrophorus americanus, was monitored on Block Island, RI, USA, from 1991-2003 using mark-recapture population estimates of adults collected in pitfall traps. Populations increased through time, especially after 1994 when a program was initiated that provided carrion for beetle production. Beetle captures increased with increasing temperature and dew point, and decreased with increasing wind speed. Short distance movement was not related to wind direction, while longer distance flights tended to be downwind. Although many individuals flew considerable distances along transects, most recaptures were in traps near the point of release. These behaviors probably have counterbalancing effects on population estimates.
Investigation of the dew-point temperature scale maintained at the MIKES
NASA Astrophysics Data System (ADS)
Heinonen, Martti
1999-01-01
For the investigation of the dew-point temperature scale realized by the MIKES primary dew-point generator, a two-pressure generator and a dew-point indicator based on condensation in a cooled coil were constructed and tested. In addition, a chilled mirror hygrometer was validated by means of an uncertainty analysis. The comparison of these systems was focused on the dew-point temperature range from 0957-0233/10/1/010/img1 to 0957-0233/10/1/010/img2 but measurements were made up to 0957-0233/10/1/010/img3. The generator systems were compared using a dew-point comparator based on two relative humidity sensors. According to the results of the comparisons, the differences between the measurement systems were less than 0957-0233/10/1/010/img4, while the expanded uncertainty of the MIKES generator was between 0957-0233/10/1/010/img5 and 0957-0233/10/1/010/img6. The uncertainty of the other systems was from 0957-0233/10/1/010/img7 to 0957-0233/10/1/010/img8. It was concluded that the dew-point temperature scale was not dependent on the realization method.
Temporal trends in United States dew point temperatures
NASA Astrophysics Data System (ADS)
Robinson, Peter J.
2000-07-01
In this study, hourly data for the 1951-1990 period for 178 stations in the coterminous United States were used to establish temporal trends in dew point temperature. Although the data had been quality controlled previously (Robinson, 1998. Monthly variations of dew point temperatures in the coterminous United States. International Journal of Climatology 18: 1539-1556), comparisons of values between nearby stations suggested that instrumental changes, combined with locational changes, may have modified the results by as much as 1°C during the 40-year period. Nevertheless, seasonally averaged results indicated an increase over much of the area, of slightly over 1°C/100 years in spring and autumn, slightly less than this in summer. Winter displayed a drying of over 1°C/100 years. When only the 1961-1990 period was considered, the patterns were similar and trends increased by approximately 1-2°C/100 years, except in autumn, which displayed a slight drying. Analyses for specific stations indicated periods of both increasing and decreasing Td, the change between them varying with observation hour. No single change point was common over a wide area, although January commonly indicated maximum values early in the period in the east and west, and much later in the north-central portion. Rates of increase were generally higher in daytime than at night, especially in summer. Investigation of the inter-decadal differences in dew point, as a function of wind conditions, indicated that changes during calm conditions were commonly similar in magnitude to that of the overall average changes, suggesting an important role for the local hydrologic cycle in driving changes. Other inter-decadal changes could be attributed to the changes in the frequency and moisture content of invading air-streams. This was particularly clear for the changes in north-south flow in the interior.
A new comparison method for dew-point generators
NASA Astrophysics Data System (ADS)
Heinonen, Martti
1999-12-01
A new method for comparing dew-point generators was developed at the Centre for Metrology and Accreditation. In this method, the generators participating in a comparison are compared with a transportable saturator unit using a dew-point comparator. The method was tested by constructing a test apparatus and by comparing it with the MIKES primary dew-point generator several times in the dew-point temperature range from -40 to +75 °C. The expanded uncertainty (k = 2) of the apparatus was estimated to be between 0.05 and 0.07 °C and the difference between the comparator system and the generator is well within these limits. In particular, all of the results obtained in the range below 0 °C are within ±0.03 °C. It is concluded that a new type of a transfer standard with characteristics most suitable for dew-point comparisons can be developed on the basis of the principles presented in this paper.
Dew-point measurements at high water vapour pressure
NASA Astrophysics Data System (ADS)
Lomperski, S.; Dreier, J.
1996-05-01
A dew-point meter capable of measuring humidity at high vapour pressure and high temperature has been constructed and tested. Humidity measurements in pure steam were made over the temperature range 100 - 1500957-0233/7/5/003/img1C and a vapour pressure range of 1 - 4 bar. The dew-point meter performance was assessed by comparing measurements with a pressure transmitter and agreement between the two was within 0957-0233/7/5/003/img2% relative humidity. Humidity measurements in steam - air mixtures were also made and the dew-point meter readings were compared to those of a zirconia oxygen sensor. For these tests the dew-point meter readings were generally within 0957-0233/7/5/003/img2% relative humidity of the oxygen sensor measurements.
NASA Astrophysics Data System (ADS)
Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il
2008-11-01
Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.
Surface and Tower Meteorological Instrumentation at NSA Handbook - January 2006
DOE Office of Scientific and Technical Information (OSTI.GOV)
MT Ritsche
2006-01-30
The Surface and Tower Meteorological Instrumentation at Atqasuk (METTWR2H) uses mainly conventional in situ sensors to measure wind speed, wind direction, air temperature, dew point and humidity mounted on a 10-m tower. It also obtains barometric pressure, visibility, and precipitation data from sensors at or near the base of the tower. In addition, a Chilled Mirror Hygrometer is located at 1 m for comparison purposes. Temperature and relative humidity probes are mounted at 2 m and 5 m on the tower. For more information, see the Surface and Tower Meteorological Instrumentation at Atqasuk Handbook.
1978-06-12
PRECIPITATION PSYCHROMETRIC-DRY VS WET BULB SNOWFALL MEAN & STD DEV. (DRY BULB, WIT BULB, & DEW POINT) SNOW DEPTH RELATIVE HUMIDITY PARTC SURFACE WINDS PART D...CONDITIONS FROM HOURLY OBSERVATIONS JU 00.jAN/RRI 0 RAIN FREEZING SNOW %OF SMOKE DUST % OF OSS TOTAL MONTH HUS TOURS HAt SAND TOT FOSAD/ RTO HOUS. THUNDR.ADOl...WEATHFR 1500-1700. CLAS VS MIEN(LT.) CONDITION SPEED IMEAN (KNTS) 1.3 4.6 7.10 11.16 17.21 22.27V 2833 34. 40 41.47 43.55 ?:56 % WIND cit. ISPEED N 1.1
NASA Technical Reports Server (NTRS)
Goodman, Brian M.; Diak, George R.; Mills, Graham A.
1986-01-01
A system for assimilating conventional meteorological data and satellite-derived data in order to produce four-dimensional gridded data sets of the primary atmospheric variables used for updating limited area forecast models is described. The basic principles of a data assimilation scheme as proposed by Lorenc (1984) are discussed. The design of the system and its incremental assimilation cycles are schematically presented. The assimilation system was tested using radiosonde, buoy, VAS temperature, dew point, gradient wind data, cloud drift, and water vapor motion data. The rms vector errors for the data are analyzed.
Precipitation Field and Intrastorm Flow of Supercell Convective Storms.
1981-08-01
1978: Observations of radome transmission losses at 5 cm wavelengths. Preprints 18th Conf. on Radar Meteor., Atlanta, Amer. Meteor. Soc., 288-291. , and...La, and Lr are loss factors (dimensionless) for the radome, the transmission path, and atmospheric gaseous absorp- tion. Typical values are Lc - 2dB...surface fields. Objectively analyzed maps of streamflow , wind com- ponents, temperature, dew point, pressure, divergence, vorticity, mix- ing ratio, and
Effects of climatic variables on weight loss: a global analysis.
Ustulin, Morena; Keum, Changwon; Woo, Junghoon; Woo, Jeong-Taek; Rhee, Sang Youl
2017-01-20
Several studies have analyzed the effects of weather on factors associated with weight loss. In this study, we directly analyzed the effect of weather on intentional weight loss using global-scale data provided by smartphone applications. Through Weather Underground API and the Noom Coach application, we extracted information on weather and body weight for each user located in each of several geographic areas on all login days. We identified meteorological information (pressure, precipitation, wind speed, dew point, and temperature) and self-monitored body weight data simultaneously. A linear mixed-effects model was performed analyzing 3274 subjects. Subjects in North America had higher initial BMIs than those of subjects in Eastern Asia. During the study period, most subjects who used the smartphone application experienced weight loss in a significant way (80.39%, p-value < 0.001). Subjects who infrequently recorded information about dinner had smaller variations than those of other subjects (β freq.users dinner*time = 0.007, p-value < 0.001). Colder temperature, lower dew point, and higher values for wind speed and precipitation were significantly associated with weight loss. In conclusion, we found a direct and independent impact of meteorological conditions on intentional weight loss efforts on a global scale (not only on a local level).
Effects of climatic variables on weight loss: a global analysis
Ustulin, Morena; Keum, Changwon; Woo, Junghoon; Woo, Jeong-taek; Rhee, Sang Youl
2017-01-01
Several studies have analyzed the effects of weather on factors associated with weight loss. In this study, we directly analyzed the effect of weather on intentional weight loss using global-scale data provided by smartphone applications. Through Weather Underground API and the Noom Coach application, we extracted information on weather and body weight for each user located in each of several geographic areas on all login days. We identified meteorological information (pressure, precipitation, wind speed, dew point, and temperature) and self-monitored body weight data simultaneously. A linear mixed-effects model was performed analyzing 3274 subjects. Subjects in North America had higher initial BMIs than those of subjects in Eastern Asia. During the study period, most subjects who used the smartphone application experienced weight loss in a significant way (80.39%, p-value < 0.001). Subjects who infrequently recorded information about dinner had smaller variations than those of other subjects (βfreq.users dinner*time = 0.007, p-value < 0.001). Colder temperature, lower dew point, and higher values for wind speed and precipitation were significantly associated with weight loss. In conclusion, we found a direct and independent impact of meteorological conditions on intentional weight loss efforts on a global scale (not only on a local level). PMID:28106167
Removal mechanisms of dew via self-propulsion off the gecko skin.
Watson, Gregory S; Schwarzkopf, Lin; Cribb, Bronwen W; Myhra, Sverre; Gellender, Marty; Watson, Jolanta A
2015-04-06
Condensation resulting in the formation of water films or droplets is an unavoidable process on the cuticle or skin of many organisms. This process generally occurs under humid conditions when the temperature drops below the dew point. In this study, we have investigated dew conditions on the skin of the gecko Lucasium steindachneri. When condensation occurs, we show that small dew drops, as opposed to a thin film, form on the lizard's scales. As the droplets grow in size and merge, they can undergo self-propulsion off the skin and in the process can be carried away a sufficient distance to freely engage with external forces. We show that factors such as gravity, wind and fog provide mechanisms to remove these small droplets off the gecko skin surface. The formation of small droplets and subsequent removal from the skin may aid in reducing microbial contact (e.g. bacteria, fungi) and limit conducive growth conditions under humid environments. As well as providing an inhospitable microclimate for microorganisms, the formation and removal of small droplets may also potentially aid in other areas such as reduction and cleaning of some surface contaminants consisting of single or multiple aggregates of particles. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
New methods of subcooled water recognition in dew point hygrometers
NASA Astrophysics Data System (ADS)
Weremczuk, Jerzy; Jachowicz, Ryszard
2001-08-01
Two new methods of sub-cooled water recognition in dew point hygrometers are presented in this paper. The first one- impedance method use a new semiconductor mirror in which the dew point detector, the thermometer and the heaters were integrated all together. The second one an optical method based on a multi-section optical detector is discussed in the report. Experimental results of both methods are shown. New types of dew pont hydrometers of ability to recognized sub-cooled water were proposed.
High performance miniature hygrometer and method thereof
NASA Technical Reports Server (NTRS)
VanZandt, Thomas R. (Inventor); Kaiser, William J. (Inventor); Kenny, Thomas W. (Inventor); Crisp, David (Inventor)
1994-01-01
An uncoated interdigitated transducer is cooled from a temperature above the dew point to a temperature below the dew point, while a parameter of a signal of the transducer is measured. The reduction in temperature causes a monotonic change in transducer signal because that signal is sensitive primarily to the water loading of the transducer surface as water forms on that surface due to the reduction in temperature. As the dew point is approached with temperature reduction, the slope of the curve of transducer signal with respect to temperature, remains relatively constant. However, as the dew point is reached the slope of that curve increases and because of changes in the structure of the water layer on the surface of the transducer, at the dew point the transducer responds with a clear shift in the rate at which the transducer signal changes. The temperature at which the second derivative of signal vs. temperature peaks can be readily used to identify with extreme accuracy, the precise dew point. The measurement technique employed by the present invention is relatively immune to surface contamination which remains significantly unchanged during the brief measurement period.
Kingston, J K; Geor, R J; McCutcheon, L J
1997-02-01
To compare dew-point hygrometry, direct sweat collection, and measurement of body water loss as methods for determination of sweating rate (SR) in exercising horses. 6 exercise-trained Thoroughbreds. SR was measured in 6 horses exercising at 40% of the speed that elicited maximum oxygen consumption for 45 km, with a 15-minute rest at the end of each 15-km phase. Each horse completed 2 exercise trials. Dew-point hygrometry, as a method of local SR determination, was validated in vitro by measurement of rate of evaporative water loss. During exercise, local SR was determined every 10 minutes by the following 2 methods: (1) dew-point hygrometry on the neck and lateral area of the thorax, and (2) on the basis of the volume of sweat collected from a sealed plastic pouch attached to the lateral area of the thorax. Mean whole body SR was calculated from total body water loss incurred during exercise. Evaporation rate measured by use of dew-point hygrometry was significantly correlated (r2 = 0.92) with the actual rate of evaporative water loss. There was a similar pattern of change in SR measured by dew-point hygrometry on the neck and lateral area of the thorax during exercise, with a significantly higher SR on the neck. The SR measured on the thorax by direct sweat collection and by dew-point hygrometry were of similar magnitude. Mean whole body SR calculated from total body water loss was not significantly different from mean whole body SR estimated from direct sweat collection or dew-point hygrometry measurements on the thorax. Dew-point hygrometry and direct sweat collection are useful methods for determination of local SR in horses during prolonged, steady-state exercise in moderate ambient conditions. Both methods of local SR determination provide an accurate estimated of whole body SR.
A field investigation and numerical simulation of coastal fog
NASA Technical Reports Server (NTRS)
Mack, E. J.; Eadie, W. J.; Rogers, C. W.; Kocmond, W. C.; Pilie, R. J.
1973-01-01
A field investigation of the microphysical and micrometeorological features of fogs occurring near Los Angeles and Vandenberg, California was conducted. Observations of wind speed and direction, temperature, dew point, vertical wind velocity, dew deposition, drop-size distribution, liquid water content, and haze and cloud nucleus concentration were obtained. These observations were initiated in late evening prior to fog formation and continued until the time of dissipation in both advection and radiation fogs. Data were also acquired in one valley fog and several dense haze situations. The behavior of these parameters prior to and during fog are discussed in detail. A two-dimensional numerical model was developed to investigate the formation and dissipation of advection fogs under the influence of horizontal variations in surface temperature. The model predicts the evolution of potential temperature, water vapor content, and liquid water content in a vertical plane as determined by vertical turbulent transfer and horizontal advection. Results are discussed from preliminary numerical experiments on the formation of warm-air advection fog and dissipation by natural and artificial heating from the surface.
NASA Astrophysics Data System (ADS)
Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.
2007-01-01
This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
Memory persistency and nonlinearity in daily mean dew point across India
NASA Astrophysics Data System (ADS)
Ray, Rajdeep; Khondekar, Mofazzal Hossain; Ghosh, Koushik; Bhattacharjee, Anup Kumar
2016-04-01
Enterprising endeavour has been taken in this work to realize and estimate the persistence in memory of the daily mean dew point time series obtained from seven different weather stations viz. Kolkata, Chennai (Madras), New Delhi, Mumbai (Bombay), Bhopal, Agartala and Ahmedabad representing different geographical zones in India. Hurst exponent values reveal an anti-persistent behaviour of these dew point series. To affirm the Hurst exponent values, five different scaling methods have been used and the corresponding results are compared to synthesize a finer and reliable conclusion out of it. The present analysis also bespeaks that the variation in daily mean dew point is governed by a non-stationary process with stationary increments. The delay vector variance (DVV) method has been exploited to investigate nonlinearity, and the present calculation confirms the presence of deterministic nonlinear profile in the daily mean dew point time series of the seven stations.
Richter, Markus; McLinden, Mark O
2017-07-21
Phase equilibria of fluid mixtures are important in numerous industrial applications and are, thus, a major focus of thermophysical property research. Improved data, particularly along the dew line, are needed to improve model predictions. Here we present experimental results utilizing highly accurate densimetry to quantify the effects of sorption and capillary condensation, which exert a distorting influence on measured properties near the dew line. We investigate the (pressure, density, temperature, composition) behaviour of binary (CH 4 + C 3 H 8 ) and (Ar + CO 2 ) mixtures over the temperature range from (248.15 to 273.15) K starting at low pressures and increasing in pressure towards the dew point along isotherms. Three distinct regions are observed: (1) minor sorption effects in micropores at low pressures; (2) capillary condensation followed by wetting in macro-scale surface scratches beginning approximately 2% below the dew-point pressure; (3) bulk condensation. We hypothesize that the true dew point lies within the second region.
Estimation of Initial and Response Times of Laser Dew-Point Hygrometer by Measurement Simulation
NASA Astrophysics Data System (ADS)
Matsumoto, Sigeaki; Toyooka, Satoru
1995-10-01
The initial and the response times of the laser dew-point hygrometer were evaluated by measurement simulation. The simulation was based on loop computations of the surface temperature of a plate with dew deposition, the quantity of dew deposited and the intensity of scattered light from the surface at each short interval of measurement. The initial time was defined as the time necessary for the hygrometer to reach a temperature within ±0.5° C of the measured dew point from the start time of measurement, and the response time was also defined for stepwise dew-point changes of +5° C and -5° C. The simulation results are in approximate agreement with the recorded temperature and intensity of scattered light of the hygrometer. The evaluated initial time ranged from 0.3 min to 5 min in the temperature range from 0° C to 60° C, and the response time was also evaluated to be from 0.2 min to 3 min.
Inventory of File naefs_geavg.t12z.ndgd_conusf18.grib2
fcst Pressure [Pa] ens-mean 002 2 m above ground TMP 18 hour fcst Temperature [K] ens-mean 003 2 m above ground RH 18 hour fcst Relative Humidity [%] ens-mean 004 2 m above ground DPT 18 hour fcst Dew Point Temperature [K] ens-mean 005 10 m above ground UGRD 18 hour fcst U-Component of Wind [m/s] ens
Inventory of File naefs_geavg.t12z.ndgd_conusf30.grib2
fcst Pressure [Pa] ens-mean 002 2 m above ground TMP 30 hour fcst Temperature [K] ens-mean 003 2 m above ground RH 30 hour fcst Relative Humidity [%] ens-mean 004 2 m above ground DPT 30 hour fcst Dew Point Temperature [K] ens-mean 005 10 m above ground UGRD 30 hour fcst U-Component of Wind [m/s] ens
Inventory of File naefs_geavg.t12z.ndgd_alaskaf24.grib
fcst Pressure [Pa] ens-mean 002 2 m above ground TMP 24 hour fcst Temperature [K] ens-mean 003 2 m above ground RH 24 hour fcst Relative Humidity [%] ens-mean 004 2 m above ground DPT 24 hour fcst Dew Point Temperature [K] ens-mean 005 10 m above ground UGRD 24 hour fcst U-Component of Wind [m/s] ens
Inventory of File naefs_geavg.t12z.ndgd_alaskaf36.grib
fcst Pressure [Pa] ens-mean 002 2 m above ground TMP 36 hour fcst Temperature [K] ens-mean 003 2 m above ground RH 36 hour fcst Relative Humidity [%] ens-mean 004 2 m above ground DPT 36 hour fcst Dew Point Temperature [K] ens-mean 005 10 m above ground UGRD 36 hour fcst U-Component of Wind [m/s] ens
An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature Realization
NASA Astrophysics Data System (ADS)
Benyon, R.; Böse, N.; Mitter, H.; Mutter, D.; Vicente, T.
2012-09-01
Precision optical dew-point hygrometers are the most commonly used transfer standards for the comparison of dew-point temperature realizations at National Metrology Institutes (NMIs) and for disseminating traceability to calibration laboratories. These instruments have been shown to be highly reproducible when properly used. In order to obtain the best performance, the resistance of the platinum resistance thermometer (PRT) embedded in the mirror is usually measured with an external, traceable resistance bridge or digital multimeter. The relation between the conventional calibration of miniature PRTs, prior to their assembly in the mirrors of state-of-the-art optical dew-point hygrometers and their subsequent calibration as dew-point temperature measurement devices, has been investigated. Standard humidity generators of three NMIs were used to calibrate hygrometers of different designs, covering the dew-point temperature range from -75 °C to + 95 °C. The results span more than a decade, during which time successive improvements and modifications were implemented by the manufacturer. The findings are presented and discussed in the context of enabling the optimum use of these transfer standards and as a basis for determining contributions to the uncertainty in their calibration.
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform.
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-07-15
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard "chilled-mirror" dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional "chilled-mirror" hygrometers. Moreover, this DPS outperforms conventional "chilled-mirror" hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.
A micro dew point sensor with a thermal detection principle
NASA Astrophysics Data System (ADS)
Kunze, M.; Merz, J.; Hummel, W.-J.; Glosch, H.; Messner, S.; Zengerle, R.
2012-01-01
We present a dew point temperature sensor with the thermal detection of condensed water on a thin membrane, fabricated by silicon micromachining. The membrane (600 × 600 × ~1 µm3) is part of a silicon chip and contains a heating element as well as a thermopile for temperature measurement. By dynamically heating the membrane and simultaneously analyzing the transient increase of its temperature it is detected whether condensed water is on the membrane or not. To cool the membrane down, a peltier cooler is used and electronically controlled in a way that the temperature of the membrane is constantly held at a value where condensation of water begins. This temperature is measured and output as dew point temperature. The sensor system works in a wide range of dew point temperatures between 1 K and down to 44 K below air temperature. In experimental investigations it could be proven that the deviation of the measured dew point temperatures compared to reference values is below ±0.2 K in an air temperature range of 22 to 70 °C. At low dew point temperatures of -20 °C (air temperature = 22 °C) the deviation increases to nearly -1 K.
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform
NASA Astrophysics Data System (ADS)
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-07-01
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.
[Indoor simulation on dew formation on plant leaves].
Gao, Zhi-Yong; Wang, You-Ke; Wei, Xin-Guang; Liu, Shou-Yang; He, Zi-Li; Zhou, Yu-Hong
2014-03-01
Dew forming on plant leaves through water condensation plays a significant ecological role in arid and semi-arid areas as an ignorable fraction of water resources. In this study, an artificial intelligent climate chamber and an automatic temperature-control system for leaves were implemented to regulate the ambient temperature, the leaf surface temperature and the leaf inclination for dew formation. The impact of leaf inclination, ambient temperature and dew point-leaf temperature depression on the rate and quantity of dew accumulation on leaf surface were analyzed. The results indicated that the accumulation rate and the maximum volume of dew on leaves decreased with increasing the leaf inclination while increased with the increment of dew point-leaf temperature depression, ambient temperature and relative humidity. Under the horizontal configuration, dew accumulated linearly on leaf surface over time until the maximum volume (0.80 mm) was reached. However, dew would fall down after reaching the maximum volume when the leaf inclination existed (45 degrees or 90 degrees), significantly slowing down the accumulative rate, and the zigzag pattern for the dynamic of dew accumulation appeared.
Measurement of Vapor Flow As an Important Source of Water in Dry Land Eco-Hydrology
NASA Astrophysics Data System (ADS)
Wang, Z.; He, Z.; Wang, Y.; Gao, Z.; Hishida, K.
2014-12-01
When the temperature of land surface is lower than that of air and deeper soils, water vapor gathers toward the ground surface where dew maybe formed depending on the prevailing dew point and wind speed. Some plants are able to absorb the dew and vapor flow while the soil can readily absorb both. Certain animals such as desert beetles and ants harvest the dew or fog for daily survival. Recently, it is also realized that the dew and vapor flow can be a life-saving amount of water for plant survival at the driest seasons of the year in arid and semi-arid regions. Researches are conducted to quantify the amount of near-surface vapor flow in arid and semi-arid regions in China and USA. Quantitative leaf water absorption and desorption functions were derived based on laboratory experiments. Results show that plant leaves absorb and release water at different speeds depending on species and varieties. The "ideal" native plants in the dry climates can quickly absorb water and slowly release it. This water-holding capacity of plant is characterized by the absorption and desorption functions derived for plant physiology and water balance studies. Field studies are conducted to measure the dynamic vapor flow movements from the atmosphere and the groundwater table to soil surface. Results show that dew is usually formed on soil and plant surfaces during the daily hours when the temperature gradients are inverted toward the soil surface. The amount of dew harvested using gravels on the soil surface was enough to support water melon agriculture on deserts. The vapor flow can be effectively intercepted by artificially seeded plants in semi-arid regions forming new forests. New studies are attempted to quantify the role of vapor flow for the survival of giant sequoias in the southern Sierra Nevada Mountains of California.
NASA Astrophysics Data System (ADS)
Moritz, Katharina; Kleinrahm, Reiner; McLinden, Mark O.; Richter, Markus
2017-12-01
For the determination of dew-point densities and pressures of fluid mixtures, a new densimeter has been developed. The new apparatus is based on the well-established two-sinker density measurement principle with the additional capability of quantifying sorption effects. In the vicinity of the dew line, such effects cause a change in composition of the gas mixture under study, which can significantly distort accurate density measurements. The new experimental technique enables the accurate measurement of dew-point densities and pressures and the quantification of sorption effects at the same time.
Analysis of Multicomponent Adsorption Close to a Dew Point.
Shapiro; Stenby
1998-10-15
We develop the potential theory of multicomponent adsorption close to a dew point. The approach is based on an asymptotic adsorption equation (AAE) which is valid in a vicinity of the dew point. By this equation the thickness of the liquid film is expressed through thermodynamic characteristics of the bulk phase. The AAE makes it possible to study adsorption in the regions of both the normal and the retrograde condensation. A simple correlation of the Kelvin radius for capillary condensation and the thickness of the adsorbed film is established. Numerical testing shows good agreement between the AAE and the direct calculations, even if the mixture is not close to a dew point. Copyright 1998 Academic Press.
Galvanizability of Advanced High-Strength Steels 1180TRIP and 1180CP
NASA Astrophysics Data System (ADS)
Kim, M. S.; Kwak, J. H.; Kim, J. S.; Liu, Y. H.; Gao, N.; Tang, N.-Y.
2009-08-01
In general, Si-bearing advanced high-strength steels (AHSS) possess excellent mechanical properties but poor galvanizability. The galvanizability of a transformation-induced plasticity (TRIP) steel 1180TRIP containing 2.2 pct Mn and 1.7 pct Si and a complex phase steel 1180CP containing 2.7 pct Mn and 0.2 pct Si was extensively studied using a galvanizing simulator. The steel coupons were annealed at fixed dew points in the simulator. The surface features of the as-annealed steel coupons, together with galvanized and galvannealed coatings, were carefully examined using a variety of advanced analysis techniques. It was found that various oxides formed on the surface of these steels, depending on the steel composition and on the dew point control. Coating quality was good at 0 °C dew point but deteriorated as the dew point decreased to -35 °C and -65 °C. Based on the findings, guidance was provided for improving galvanizability by adjusting the Mn:Si ratio in steel compositions according to the dew point.
Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method.
Lin, Ningning; Meng, Xiaofeng; Nie, Jing
2016-11-18
In this paper, the influence of temperature on quartz crystal microbalance (QCM) sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of -3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability.
Comparative verification between GEM model and official aviation terminal forecasts
NASA Technical Reports Server (NTRS)
Miller, Robert G.
1988-01-01
The Generalized Exponential Markov (GEM) model uses the local standard airways observation (SAO) to predict hour-by-hour the following elements: temperature, pressure, dew point depression, first and second cloud-layer height and amount, ceiling, total cloud amount, visibility, wind, and present weather conditions. GEM is superior to persistence at all projections for all elements in a large independent sample. A minute-by-minute GEM forecasting system utilizing the Automated Weather Observation System (AWOS) is under development.
Inventory of File nam.t00z.smartak06.tm00.grib2
Temperature [K] 002 surface DPT 6 hour fcst Dew Point Temperature [K] 003 surface SPFH 6 hour fcst Specific Haines Index [Numeric] 029 surface TMP 5 hour fcst Temperature [K] 030 surface TMP 4 hour fcst Temperature [K] 031 surface DPT 5 hour fcst Dew Point Temperature [K] 032 surface DPT 4 hour fcst Dew Point
An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform
Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong
2016-01-01
The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints. PMID:27417734
Using dew points to estimate savings during a planned cooling shutdown
NASA Astrophysics Data System (ADS)
Friedlein, Matthew T.; Changnon, David; Musselman, Eric; Zielinski, Jeff
2005-12-01
In an effort to save money during the summer of 2003, Northern Illinois University (NIU) administrators instituted a four-day working week and stopped air conditioning buildings for the three-day weekends (Friday through Sunday). Shutting down the air conditioning systems caused a noticeable drop in electricity usage for that part of the campus that features in our study, with estimated total electricity savings of 1,268,492 kilowatt-hours or 17% of the average usage during that eight-week period. NIU's air conditioning systems, which relied on evaporative cooling to function, were sensitive to dew point levels. Greatest savings during the shutdown period occurred on days with higher dew points. An examination of the regional dew point climatology (1959 2003) indicated that the average summer daily dew point for 2003 was 14.9°C (58.8°F), which fell in the lowest 20% of the distribution. Based on the relationship between daily average dew points and electrical usage, a predictive model that could estimate electrical daily savings was created. This model suggests that electrical savings related to any future three-day shutdowns over summer could be much greater in more humid summers. Studies like this demonstrate the potential value of applying climatological information and of integrating this information into practical decision-making.
NASA Astrophysics Data System (ADS)
Hudoklin, Domen; Drnovšek, Janko
2008-10-01
In the field of hygrometry, a primary dew-point standard can be realized according to several proven principles, such as single-pressure (1-P), two-pressure (2-P), or divided flow. Different realizations have been introduced by various national laboratories, each resulting in a stand-alone complex generation system. Recent trends in generator design favor the single-pressure principle without recirculation because it promises theoretically lower uncertainty and because it avoids problems regarding the leak tightness of the recirculation. Instead of recirculation, the efficiency of saturation, the key factor, is increased by preconditioning the inlet gas entering the saturator. For preconditioning, a presaturator or purifier is used to bring the dew point of the inlet stream close to the saturator temperature. The purpose of the paper is to identify the minimum requirements for the preconditioning system and the main saturator to assure efficient saturation for the LMK generator. Moreover, the aim is also to find out if the preconditioning system can be avoided despite the rather simple construction of the main saturator. If this proves to be the case, the generator design can be simplified while maintaining an accurate value of the generated dew point. Experiments were carried out within the scope of improving our existing primary generator in the above-ambient dew-point range up to +70°C. These results show the generated dew point is within the measurement uncertainty for any dew-point value of the inlet gas. Thus, the preconditioning subsystem can be avoided, which leads to a simplified generator design.
New Primary Dew-Point Generators at HMI/FSB-LPM in the Range from -70 °C to +60 °C
NASA Astrophysics Data System (ADS)
Zvizdic, Davor; Heinonen, Martti; Sestan, Danijel
2012-09-01
To extend the dew-point range and to improve the uncertainties of the humidity scale realization at HMI/FSB-LPM, new primary low- and high-range dew-point generators were developed and implemented in cooperation with MIKES, in 2009 through EUROMET Project No. 912. The low-range saturator is designed for primary realization of the dew-point temperature scale from -70 °C to + 5 °C, while the high-range saturator covers the range from 1 °C to 60 °C. The system is designed as a single-pressure, single-pass dew-point generator. MIKES designed and constructed both the saturators to be implemented in dew-point calibration systems at LPM. The LPM took care of purchasing and adapting liquid baths, of implementing the temperature and pressure measurement equipment appropriate for use in the systems, and development of gas preparation and flow control systems as well as of the computer-based automated data acquisition. The principle and the design of the generator are described in detail and schematically depicted. The tests were performed at MIKES to investigate how close both the saturators are to an ideal saturator. Results of the tests show that both the saturators are efficient enough for a primary realization of the dew-point temperature scale from -70 °C to + 60 °C, in the specified flow-rate ranges. The estimated standard uncertainties due to the non-ideal saturation efficiency are between 0.02 °C and 0.05 °C.
Inventory of File nam.t00z.smartpr12.tm00.grib2
Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific 11 hour fcst Temperature [K] 032 surface TMP 10 hour fcst Temperature [K] 033 surface DPT 11 hour fcst Dew Point Temperature [K] 034 surface DPT 10 hour fcst Dew Point Temperature [K] 035 surface TMAX
Inventory of File nam.t00z.smartak03.tm00.grib2
Temperature [K] 002 surface DPT 3 hour fcst Dew Point Temperature [K] 003 surface SPFH 3 hour fcst Specific fcst Haines Index [Numeric] 026 surface TMP 2 hour fcst Temperature [K] 027 surface TMP 1 hour fcst Temperature [K] 028 surface DPT 2 hour fcst Dew Point Temperature [K] 029 surface DPT 1 hour fcst Dew Point
Inventory of File nam.t00z.smartak12.tm00.grib2
Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific 11 hour fcst Temperature [K] 032 surface TMP 10 hour fcst Temperature [K] 033 surface DPT 11 hour fcst Dew Point Temperature [K] 034 surface DPT 10 hour fcst Dew Point Temperature [K] 035 surface TMAX
Inventory of File nam.t00z.smarthi12.tm00.grib2
Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific 11 hour fcst Temperature [K] 032 surface TMP 10 hour fcst Temperature [K] 033 surface DPT 11 hour fcst Dew Point Temperature [K] 034 surface DPT 10 hour fcst Dew Point Temperature [K] 035 surface TMAX
Inventory of File nam.t00z.smartconus03.tm00.grib2
Temperature [K] 002 surface DPT 3 hour fcst Dew Point Temperature [K] 003 surface SPFH 3 hour fcst Specific Temperature [K] 026 surface TMP 1 hour fcst Temperature [K] 027 surface DPT 2 hour fcst Dew Point Temperature [K] 028 surface DPT 1 hour fcst Dew Point Temperature [K] 029 surface TMAX 0-3 hour acc Maximum
Inventory of File gfs.t06z.smartguam18.tm00.grib2
Temperature [K] 002 surface DPT 18 hour fcst Dew Point Temperature [K] 003 surface SPFH 18 hour fcst Specific TMP 17 hour fcst Temperature [K] 022 surface TMP 16 hour fcst Temperature [K] 023 surface DPT 17 hour fcst Dew Point Temperature [K] 024 surface DPT 16 hour fcst Dew Point Temperature [K] 025 surface TMAX
Automatic dew-point temperature sensor.
Graichen, H; Rascati, R; Gonzalez, R R
1982-06-01
A device is described for measuring dew-point temperature and water vapor pressure in small confined areas. The method is based on the deposition of water on a cooled surface when at dew-point temperature. A small Peltier module lowers the temperature of two electrically conductive plates. At dew point the insulating gap separating the plates becomes conductive as water vapor condenses. Sensors based on this principle can be made small and rugged and can be used for measuring directly the local water vapor pressure. They may be installed within a conventional ventilated sweat capsule used for measuring water vapor loss from the skin surface. A novel application is the measurement of the water vapor pressure gradients across layers of clothing worn by an exercising subject.
Effects of dew point on selective oxidation of TRIP steels containing Si, Mn, and B
NASA Astrophysics Data System (ADS)
Lee, Suk-Kyu; Kim, Jong-Sang; Choi, Jin-Won; Kang, Namhyun; Cho, Kyung-Mox
2011-04-01
The selective oxidation of Si, Mn, and B on TRIP steel surfaces is a widely known phenomenon that occurs during heat treatment. However, the relationship between oxide formation and the annealing factors is not completely understood. This study examines the effect of the annealing conditions (dew point and annealing temperature) on oxide formation. A low dew point of -40 °C leads to the formation of Si-based oxides on the surface. A high dew point of -20 °C changes the oxide type to Mn-based oxides because the formation of Si oxides on the surface is suppressed by internal oxidation. Mn-based oxides exhibit superior wettability due to aluminothermic reduction during galvanizing.
Note: A dual-channel sensor for dew point measurement based on quartz crystal microbalance.
Li, Ning; Meng, Xiaofeng; Nie, Jing
2017-05-01
A new sensor with dual-channel was designed for eliminating the temperature effect on the frequency measurement of the quartz crystal microbalance (QCM) in dew point detection. The sensor uses active temperature control, produces condensation on the surface of QCM, and then detects the dew point. Both the single-channel and the dual-channel methods were conducted based on the device. The measurement error of the single-channel method was less than 0.5 °C at the dew point range of -2 °C-10 °C while the dual-channel was 0.3 °C. The results showed that the dual-channel method was able to eliminate the temperature effect and yield better measurement accuracy.
Note: A dual-channel sensor for dew point measurement based on quartz crystal microbalance
NASA Astrophysics Data System (ADS)
Li, Ning; Meng, Xiaofeng; Nie, Jing
2017-05-01
A new sensor with dual-channel was designed for eliminating the temperature effect on the frequency measurement of the quartz crystal microbalance (QCM) in dew point detection. The sensor uses active temperature control, produces condensation on the surface of QCM, and then detects the dew point. Both the single-channel and the dual-channel methods were conducted based on the device. The measurement error of the single-channel method was less than 0.5 °C at the dew point range of -2 °C-10 °C while the dual-channel was 0.3 °C. The results showed that the dual-channel method was able to eliminate the temperature effect and yield better measurement accuracy.
Feedback dew-point sensor utilizing optimally cut plastic optical fibres
NASA Astrophysics Data System (ADS)
Hadjiloucas, S.; Irvine, J.; Keating, D. A.
2000-01-01
A plastic optical fibre reflectance sensor that makes full use of the critical angle of the fibres is implemented to monitor dew formation on a Peltier-cooled reflector surface. The optical configuration permits isolation of optoelectronic components from the sensing head and better light coupling between the reflector and the detecting fibre, giving a better signal of the onset of dew formation on the reflector. Continuous monitoring of the rate of change in reflectance as well as the absolute reflectance signals, the use of a novel polymethyl-methacrylate-coated hydrophobic film reflector on the Peltier element and the application of feedback around the point of dew formation, further reduces the possibility of contamination of the sensor head. Under closed-loop operation, the sensor is capable of cycling around the point of dew formation at a frequency of 2.5 Hz.
Pines, M K; Phillips, C J C
2011-10-01
Noxious gases on ships are irritant pollutants that have potential impacts on the comfort and health of both livestock and humans. Identification of environmental influences on the pollutants will assist live exporters to control them. Ammonia, hydrogen sulphide and carbon dioxide, as well as wet and dry bulb temperature, dew point, air speed and depth of faeces that the sheep stood in, were measured on two ship voyages in which sheep were transported from Australia to the Middle East. Daily measurements were made at 20 measurement locations over 12 days. At four sites, the mean ammonia concentration for the voyage was above the recommended maximum limit for the live export industry (25 ppm). The mean ammonia concentrations at the remaining 16 sites were below 18 ppm and considered safe. High ammonia concentrations were localised and occurred particularly on closed decks, as well as at the front of the vessel and near the engine block on open decks. Ammonia concentration on the open decks was correlated with cumulative wind during the voyage, air speed, dew point, wet bulb temperature and faecal pad depth, and on the closed decks with dew point, and wet and dry bulb temperature. Hydrogen sulphide (<1.8 ppm) and carbon dioxide (<1900 ppm) concentrations were low and did not pose a risk to animal or human welfare or health. The results suggest that high ammonia concentrations occur in those parts of the ship where there is insufficient ventilation and/or high temperatures and humidity.
Development of measurement simulation of the laser dew-point hygrometer using an optical fiber cable
NASA Astrophysics Data System (ADS)
Matsumoto, Shigeaki
2005-02-01
In order to improve the initial and the response times of the Laser Dew-Point Hygrometer (LDH), the measurement simulation was developed on the basis of the loop computation of the surface temperature of a gold plate for dew depostition, the quantity of deposited dew and the intensity of scattered light from the surface of the plate at time interval of 5 sec during measurement. A more detailed relationship between the surface temperature of the plate and the cooling current, and the time constant of the integrator in the control circuit of the LDH were introduced in the simulation program as a function of atmospheric temperature. The simulation was more close to the actual measurement by the LDH. The simulation results indicated the possibility of improving both the times of teh LDH by the increase of the sensitivity of dew and that of the mass transfer coefficient of dew deposited on the plate surface. It was concluded that the initial and the response times could be improved to below 100sec and 120 sec, respectively in the dew-point range at room temperature, that are almost half of the those times of the original LDH.
A New Primary Dew-Point Generator at TUBITAK UME
NASA Astrophysics Data System (ADS)
Oğuz Aytekin, S.; Karaböce, N.; Heinonen, M.; Sairanen, H.
2018-05-01
An implementation of a new low-range primary humidity generator as a part of an international collaboration between TUBITAK UME and VTT MIKES was initiated as a EURAMET Project Number 1259. The dew-point generator was designed and constructed within the scope of the cooperation between TUBITAK UME and VTT MIKES in order to extend the dew-point temperature measurement capability of Humidity Laboratory of TUBITAK UME down to - 80 °C. The system was thoroughly characterized and validated at TUBITAK UME to support the evidence for dew-point temperature uncertainties. The new generator has a capability of operating in the range of - 80 °C to +10 °C, but at the moment, it was characterized down to - 60 °C. The core of the generator system is a saturator which is fully immersed in a liquid bath. Dry air is supplied to the saturator through a temperature-controlled pre-saturator. The operation of the system is based on the single-pressure generation method with a single pass, i.e., the dew-point temperature is only controlled by the saturator temperature, and the humidity-controlled air is not returned to the system after leaving of the saturator. The metrological performance of the saturator was investigated thoroughly at both National Metrology Institutes. The pre-saturator was also tested using a thermostatic bath at VTT MIKES prior to sending them to TUBITAK UME. This paper describes the principle and design of the generator in detail. The dew-point measurement system and the corresponding uncertainty analysis of the dew-point temperature scale realized with the generator in the range from - 60 °C to 10 °C is also presented.
Temperature distribution model for the semiconductor dew point detector
NASA Astrophysics Data System (ADS)
Weremczuk, Jerzy; Gniazdowski, Z.; Jachowicz, Ryszard; Lysko, Jan M.
2001-08-01
The simulation results of temperature distribution in the new type silicon dew point detector are presented in this paper. Calculations were done with use of the SMACEF simulation program. Fabricated structures, apart from the impedance detector used to the dew point detection, contained the resistive four terminal thermometer and two heaters. Two detector structures, the first one located on the silicon membrane and the second one placed on the bulk materials were compared in this paper.
USSR and Eastern Europe Scientific Abstracts, Engineering and Equipment, Number 36.
1977-11-30
DEW POINT OF EXHAUST GASES FROM PULVERIZERS Moscow ELEKTRICHESKIYE STANTSII in Russian No 5, May 77 pp 7-9 MIKHAYLOV, N. M., and GLUSHKINA, B. S., All...moist coal may drop below the dew point and thus cause intensive corrosion of pipes as well as machinery. Sulfur oxides (especially SO3) contained...in the combustion products raise the dew point but, being completely adsorbed by ash and residual fuel particles, cannot serve as an effective
14821AT LANCE, Missile Number 2419, Round Number 349APT, 12 May 1980.
1980-05-01
WSTRUCTIONUREPOT DCUMNTAIONPAG EPORE COMPLEMON PORN REPORT NUMBER 2GOTACCESSION NO S. RECIPIENT’S CATALOG NUMBER TDR 1148 __7 0_____T___ ~. *.~----...,S. TYPE OF...Data at 0815 MDT ---------- 4 4. White Sands Desert Site (WSD) Significant Level Data at 0815 MDT ------------------------------------ 5 5. WSD Upper...humidity, dew point (0 C), density (gm/n,3), Wind direction and speed, and cloud cover were made at the LC-39 Met Site at T-0 minutes. (2) Monitor of
NASA Astrophysics Data System (ADS)
Famiglietti, C.; Fisher, J.; Halverson, G. H.
2017-12-01
This study validates a method of remote sensing near-surface meteorology that vertically interpolates MODIS atmospheric profiles to surface pressure level. The extraction of air temperature and dew point observations at a two-meter reference height from 2001 to 2014 yields global moderate- to fine-resolution near-surface temperature distributions that are compared to geographically and temporally corresponding measurements from 114 ground meteorological stations distributed worldwide. This analysis is the first robust, large-scale validation of the MODIS-derived near-surface air temperature and dew point estimates, both of which serve as key inputs in models of energy, water, and carbon exchange between the land surface and the atmosphere. Results show strong linear correlations between remotely sensed and in-situ near-surface air temperature measurements (R2 = 0.89), as well as between dew point observations (R2 = 0.77). Performance is relatively uniform across climate zones. The extension of mean climate-wise percent errors to the entire remote sensing dataset allows for the determination of MODIS air temperature and dew point uncertainties on a global scale.
Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method
Lin, Ningning; Meng, Xiaofeng; Nie, Jing
2016-01-01
In this paper, the influence of temperature on quartz crystal microbalance (QCM) sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of −3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability. PMID:27869746
Dew point measurement technique utilizing fiber cut reflection
NASA Astrophysics Data System (ADS)
Kostritskii, S. M.; Dikevich, A. A.; Korkishko, Yu. N.; Fedorov, V. A.
2009-05-01
The fiber optical dew point hygrometer based on change of reflection coefficient for fiber cut has been developed and examined. We proposed and verified the model of condensation detector functioning principle. Experimental frost point measurements on air with different frost points have been performed.
Cape Canaveral, Florida range reference atmosphere 0-70 km altitude
NASA Technical Reports Server (NTRS)
Tingle, A. (Editor)
1983-01-01
The RRA contains tabulations for monthly and annual means, standard deviations, skewness coefficients for wind speed, pressure temperature, density, water vapor pressure, virtual temperature, dew-point temperature, and the means and standard deviations for the zonal and meridional wind components and the linear (product moment) correlation coefficient between the wind components. These statistical parameters are tabulated at the station elevation and at 1 km intervals from sea level to 30 km and at 2 km intervals from 30 to 90 km altitude. The wind statistics are given at approximately 10 m above the station elevations and at altitudes with respect to mean sea level thereafter. For those range sites without rocketsonde measurements, the RRAs terminate at 30 km altitude or they are extended, if required, when rocketsonde data from a nearby launch site are available. There are four sets of tables for each of the 12 monthly reference periods and the annual reference period.
High-resolution grids of hourly meteorological variables for Germany
NASA Astrophysics Data System (ADS)
Krähenmann, S.; Walter, A.; Brienen, S.; Imbery, F.; Matzarakis, A.
2018-02-01
We present a 1-km2 gridded German dataset of hourly surface climate variables covering the period 1995 to 2012. The dataset comprises 12 variables including temperature, dew point, cloud cover, wind speed and direction, global and direct shortwave radiation, down- and up-welling longwave radiation, sea level pressure, relative humidity and vapour pressure. This dataset was constructed statistically from station data, satellite observations and model data. It is outstanding in terms of spatial and temporal resolution and in the number of climate variables. For each variable, we employed the most suitable gridding method and combined the best of several information sources, including station records, satellite-derived data and data from a regional climate model. A module to estimate urban heat island intensity was integrated for air and dew point temperature. Owing to the low density of available synop stations, the gridded dataset does not capture all variations that may occur at a resolution of 1 km2. This applies to areas of complex terrain (all the variables), and in particular to wind speed and the radiation parameters. To achieve maximum precision, we used all observational information when it was available. This, however, leads to inhomogeneities in station network density and affects the long-term consistency of the dataset. A first climate analysis for Germany was conducted. The Rhine River Valley, for example, exhibited more than 100 summer days in 2003, whereas in 1996, the number was low everywhere in Germany. The dataset is useful for applications in various climate-related studies, hazard management and for solar or wind energy applications and it is available via doi: 10.5676/DWD_CDC/TRY_Basis_v001.
2014-01-01
Background Plasmodium falciparum transmission has decreased significantly in Zambia in the last decade. The malaria transmission is influenced by environmental variables. Incorporation of environmental variables in models of malaria transmission likely improves model fit and predicts probable trends in malaria disease. This work is based on the hypothesis that remotely-sensed environmental factors, including nocturnal dew point, are associated with malaria transmission and sustain foci of transmission during the low transmission season in the Southern Province of Zambia. Methods Thirty-eight rural health centres in Southern Province, Zambia were divided into three zones based on transmission patterns. Correlations between weekly malaria cases and remotely-sensed nocturnal dew point, nocturnal land surface temperature as well as vegetation indices and rainfall were evaluated in time-series analyses from 2012 week 19 to 2013 week 36. Zonal as well as clinic-based, multivariate, autoregressive, integrated, moving average (ARIMAX) models implementing environmental variables were developed to model transmission in 2011 week 19 to 2012 week 18 and forecast transmission in 2013 week 37 to week 41. Results During the dry, low transmission season significantly higher vegetation indices, nocturnal land surface temperature and nocturnal dew point were associated with the areas of higher transmission. Environmental variables improved ARIMAX models. Dew point and normalized differentiated vegetation index were significant predictors and improved all zonal transmission models. In the high-transmission zone, this was also seen for land surface temperature. Clinic models were improved by adding dew point and land surface temperature as well as normalized differentiated vegetation index. The mean average error of prediction for ARIMAX models ranged from 0.7 to 33.5%. Forecasts of malaria incidence were valid for three out of five rural health centres; however, with poor results at the zonal level. Conclusions In this study, the fit of ARIMAX models improves when environmental variables are included. There is a significant association of remotely-sensed nocturnal dew point with malaria transmission. Interestingly, dew point might be one of the factors sustaining malaria transmission in areas of general aridity during the dry season. PMID:24927747
Nygren, David; Stoyanov, Cristina; Lewold, Clemens; Månsson, Fredrik; Miller, John; Kamanga, Aniset; Shiff, Clive J
2014-06-13
Plasmodium falciparum transmission has decreased significantly in Zambia in the last decade. The malaria transmission is influenced by environmental variables. Incorporation of environmental variables in models of malaria transmission likely improves model fit and predicts probable trends in malaria disease. This work is based on the hypothesis that remotely-sensed environmental factors, including nocturnal dew point, are associated with malaria transmission and sustain foci of transmission during the low transmission season in the Southern Province of Zambia. Thirty-eight rural health centres in Southern Province, Zambia were divided into three zones based on transmission patterns. Correlations between weekly malaria cases and remotely-sensed nocturnal dew point, nocturnal land surface temperature as well as vegetation indices and rainfall were evaluated in time-series analyses from 2012 week 19 to 2013 week 36. Zonal as well as clinic-based, multivariate, autoregressive, integrated, moving average (ARIMAX) models implementing environmental variables were developed to model transmission in 2011 week 19 to 2012 week 18 and forecast transmission in 2013 week 37 to week 41. During the dry, low transmission season significantly higher vegetation indices, nocturnal land surface temperature and nocturnal dew point were associated with the areas of higher transmission. Environmental variables improved ARIMAX models. Dew point and normalized differentiated vegetation index were significant predictors and improved all zonal transmission models. In the high-transmission zone, this was also seen for land surface temperature. Clinic models were improved by adding dew point and land surface temperature as well as normalized differentiated vegetation index. The mean average error of prediction for ARIMAX models ranged from 0.7 to 33.5%. Forecasts of malaria incidence were valid for three out of five rural health centres; however, with poor results at the zonal level. In this study, the fit of ARIMAX models improves when environmental variables are included. There is a significant association of remotely-sensed nocturnal dew point with malaria transmission. Interestingly, dew point might be one of the factors sustaining malaria transmission in areas of general aridity during the dry season.
NASA Astrophysics Data System (ADS)
Safeeq, Mohammad; Fares, Ali
2011-12-01
Daily and sub-daily weather data are often required for hydrological and environmental modeling. Various weather generator programs have been used to generate synthetic climate data where observed climate data are limited. In this study, a weather data generator, ClimGen, was evaluated for generating information on daily precipitation, temperature, and wind speed at four tropical watersheds located in Hawai`i, USA. We also evaluated different daily to sub-daily weather data disaggregation methods for precipitation, air temperature, dew point temperature, and wind speed at Mākaha watershed. The hydrologic significance values of the different disaggregation methods were evaluated using Distributed Hydrology Soil Vegetation Model. MuDRain and diurnal method performed well over uniform distribution in disaggregating daily precipitation. However, the diurnal method is more consistent if accurate estimates of hourly precipitation intensities are desired. All of the air temperature disaggregation methods performed reasonably well, but goodness-of-fit statistics were slightly better for sine curve model with 2 h lag. Cosine model performed better than random model in disaggregating daily wind speed. The largest differences in annual water balance were related to wind speed followed by precipitation and dew point temperature. Simulated hourly streamflow, evapotranspiration, and groundwater recharge were less sensitive to the method of disaggregating daily air temperature. ClimGen performed well in generating the minimum and maximum temperature and wind speed. However, for precipitation, it clearly underestimated the number of extreme rainfall events with an intensity of >100 mm/day in all four locations. ClimGen was unable to replicate the distribution of observed precipitation at three locations (Honolulu, Kahului, and Hilo). ClimGen was able to reproduce the distributions of observed minimum temperature at Kahului and wind speed at Kahului and Hilo. Although the weather data generation and disaggregation methods were concentrated in a few Hawaiian watersheds, the results presented can be used to similar mountainous location settings, as well as any specific locations aimed at furthering the site-specific performance evaluation of these tested models.
A very large dew and rain ridge collector in the Kutch area (Gujarat, India)
NASA Astrophysics Data System (ADS)
Sharan, G.; Clus, O.; Singh, S.; Muselli, M.; Beysens, D.
2011-07-01
SummaryThe world's largest dew and rain collecting system, comprised of ridge-and-trough modules, was constructed in March 2006 at Panandhro in the semi-arid area of Kutch (NW India). The main goals were (i) to collect dew on a scale that could be beneficial to the local population (ii) to determine the efficiency of this new module shape, (iii) to determine whether results obtained from small measurement condensers can be projected to large condensers, (iv) to apply a computational fluid dynamic simulation to improve the condenser set-up. Preliminary studies performed with four standard plane condensers of 1 m 2 surface area, inclined 30° from horizontal, identified Panandhro as a promising site. The cumulated dew water during 192 days was 12.6 mm with a maximum of 0.556 mm/night. A large dew condenser (850 m 2 net total surface) was designed with 10 ridge-and-trough modules. The ridges are trapezoidal, 33 m long, 0.5 m wide at the top, 2.2 m wide at the base and sloping 30° from horizontal. The depth of the troughs between the ridges is 0.5 m. A 2.5 cm thick polystyrene foam rests on the surface as insulation with a radiative foil on top (similar to that developed by OPUR, see www.opur.fr). Numerical simulations using the computational fluid dynamic software PHOENICS were performed. The most profitable orientation was with the condenser oriented back to the wind direction, a configuration that lowers the wind velocity near the foil due to the combination of free convection and wind recirculation flows. A comparison of water yields over one year of measurements between four 1 m 2 plane condensers and a 850 m 2 ridge condenser showed a 42% lower yield on the large condenser. The difference is attributed mainly to folds in the plastic foil allowing water to fill the central ridge, thus decreasing radiative cooling. The output for 2007 was 6545 L, corresponding to 7.7 mm/day on average. The largest event was 251.4 L/night (0.3 mm). Such a condenser can also collect rain (and, to a lesser extent, fog). Chemical and biological analyses showed that dew water, once filtered and bottled, could be used for drinking after a light treatment to increase the pH. The price of this water could be lowered to reach 30% (dew only) or even 3% (dew plus rain) of the market prize.
Effects of dew deposition on transpiration and carbon uptake in leaves
NASA Astrophysics Data System (ADS)
Gerlein-Safdi, C.; Koohafkan, M.; Chung, M.; Rockwell, F. E.; Thompson, S. E.; Caylor, K. K.
2017-12-01
Dew deposition occurs in ecosystems worldwide, even in the driest deserts and in times of drought. Although some species absorb dew water directly via foliar uptake, a ubiquitous effect of dew on plant water balance is the interference of dew droplets with the leaf energy balance, which increases leaf albedo and emissivity and decreases leaf temperature through dew evaporation. Dew deposition frequency and amount are expected to be affected by changing environmental conditions, with unknown consequences for plant water stress and ecosystem carbon, water and energy fluxes. Here we present a simple leaf energy balance that characterizes the effect of deposition and the evaporation of dew on leaf energy balance, transpiration, and carbon uptake. The model is driven by five common meteorological variables and shows very good agreement with leaf wetness sensor data from the Blue Oak Ranch Reserve in California. We explore the tradeoffs between energy, water, and carbon balances for leaves of different sizes across a range of relative humidity, wind speed, and air temperature conditions. Our results show significant water savings from transpiration suppression up to 30% for leaf characteristic lengths of 50 cm due to the decrease in leaf temperature. C. 25% of water savings from transpiration suppression in smaller leaves arise from the effect of dew droplets on leaf albedo. CO2 assimilation is decreased by up to 15% by the presence of dew, except for bigger leaves in windspeed conditions below 1 m/s when an increase in assimilation is expected.
Determination of dew point conditions for CO2 with impurities using microfluidics.
Song, Wen; Fadaei, Hossein; Sinton, David
2014-03-18
Impurities can greatly modify the phase behavior of carbon dioxide (CO2), with significant implications on the safety and cost of transport in pipelines. In this paper we demonstrate a microfluidic approach to measure the dew point of such mixtures, specifically the point at which water in supercritical CO2 mixtures condenses to a liquid state. The method enables direct visualization of dew formation (∼ 1-2 μm diameter droplets) at industrially relevant concentrations, pressures, and temperatures. Dew point measurements for the well-studied case of pure CO2-water agreed well with previous theoretical and experimental data over the range of pressure (up to 13.17 MPa), temperature (up to 50 °C), and water content (down to 0.00229 mol fraction) studied. The microfluidic approach showed a nearly 3-fold reduction in error as compared to previous methods. When applied to a mixture with nitrogen (2.5%) and oxygen (5.8%) impurities--typical of flue gas from natural gas oxy-fuel combustion processes--the measured dew point pressure increased on average 17.55 ± 5.4%, indicating a more stringent minimum pressure for pipeline transport. In addition to increased precision, the microfluidic method offers a direct measurement of dew formation, requires very small volumes (∼ 10 μL), and is applicable to ultralow water contents (<0.005 mol fractions), circumventing the limits of previous methods.
The influence of dew point during annealing on the power loss of electrical steel sheets
NASA Astrophysics Data System (ADS)
Broddefalk, Arvid; Jenkins, Keith; Silk, Nick; Lindenmo, Magnus
Decarburization is a necessary part of the processing of electrical steels if their carbon content is above a certain level. The process is usually carried out in a wet hydrogen-nitrogen atmosphere. Having a high dew point has a negative influence on the power loss, though. This is due to oxidation of the steel, which hinders domain wall motion near the surface. In this study, an increase of the power loss was only observed at a fairly high dew point (>20 °C). It was also only at these high dew points where a subsurface oxide layer was observed. The surfaces of samples with and without this layer were etched in steps. The magnetic properties of the etched samples corresponded well with the expected behavior based on GDOES profiles of the samples.
A novel method of measuring the concentration of anaesthetic vapours using a dew-point hygrometer.
Wilkes, A R; Mapleson, W W; Mecklenburgh, J S
1994-02-01
The Antoine equation relates the saturated vapour pressure of a volatile substance, such as an anaesthetic agent, to the temperature. The measurement of the 'dew-point' of a dry gas mixture containing a volatile anaesthetic agent by a dew-point hygrometer permits the determination of the partial pressure of the anaesthetic agent. The accuracy of this technique is limited only by the accuracy of the Antoine coefficients and of the temperature measurement. Comparing measurements by the dew-point method with measurements by refractometry showed systematic discrepancies up to 0.2% and random discrepancies with SDS up to 0.07% concentration in the 1% to 5% range for three volatile anaesthetics. The systematic discrepancies may be due to errors in available data for the vapour pressures and/or the refractive indices of the anaesthetics.
Dew point fast measurement in organic vapor mixtures using quartz resonant sensor
NASA Astrophysics Data System (ADS)
Nie, Jing; Liu, Jia; Meng, Xiaofeng
2017-01-01
A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.
Dew point fast measurement in organic vapor mixtures using quartz resonant sensor.
Nie, Jing; Liu, Jia; Meng, Xiaofeng
2017-01-01
A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.
Critical point analysis of phase envelope diagram
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soetikno, Darmadi; Siagian, Ucok W. R.; Kusdiantara, Rudy, E-mail: rkusdiantara@s.itb.ac.id
2014-03-24
Phase diagram or phase envelope is a relation between temperature and pressure that shows the condition of equilibria between the different phases of chemical compounds, mixture of compounds, and solutions. Phase diagram is an important issue in chemical thermodynamics and hydrocarbon reservoir. It is very useful for process simulation, hydrocarbon reactor design, and petroleum engineering studies. It is constructed from the bubble line, dew line, and critical point. Bubble line and dew line are composed of bubble points and dew points, respectively. Bubble point is the first point at which the gas is formed when a liquid is heated. Meanwhile,more » dew point is the first point where the liquid is formed when the gas is cooled. Critical point is the point where all of the properties of gases and liquids are equal, such as temperature, pressure, amount of substance, and others. Critical point is very useful in fuel processing and dissolution of certain chemicals. Here in this paper, we will show the critical point analytically. Then, it will be compared with numerical calculations of Peng-Robinson equation by using Newton-Raphson method. As case studies, several hydrocarbon mixtures are simulated using by Matlab.« less
NASA Technical Reports Server (NTRS)
Rosner, D. E.; Nagarajan, R.
1985-01-01
Partial heterogeneous condensation phenomena in multicomponent reacting systems are analyzed taking into consideration the chemical element transport phenomena. It is demonstrated that the dew-point surface temperature in chemically reactive systems is not a purely thermodynamic quantity, but is influenced by the multicomponent diffusion and Soret-mass diffusion phenomena. Several distinct dew-points are shown to exist in such systems and, as a result of transport constraints, the 'sharp' locus between two chemically distinct condensates is systematically moved to a difference mainstream composition.
A MEMS-based super fast dew point hygrometer—construction and medical applications
NASA Astrophysics Data System (ADS)
Jachowicz, Ryszard S.; Weremczuk, Jerzy; Paczesny, Daniel; Tarapata, Grzegorz
2009-12-01
The paper shows how MEMS (micro-electro-mechanical system) technology and a modified principle of fast temperature control (by heat injection instead of careful control of cooling) can considerably improve the dynamic parameters of dew point hygrometers. Some aspects of MEMS-type integrated sensor construction and technology, whole measurement system design, the control algorithm to run the system as well as empirical dynamic parameters from the tests are discussed too. The hygrometer can easily obtain five to six measurements per second with an uncertainty of less than 0.3 K. The meter range is between -10 °C and 40 °C dew point. In the second part of the paper (section 2), two different successful applications in medicine based on fast humidity measurements have been discussed. Some specific constructions of these super fast dew point hygrometers based on a MEMS sensor as well as limited empirical results from clinical tests have been reported too.
NREL National Wind Technology Center (NWTC): M2 Tower; Boulder, Colorado (Data)
Jager, D.; Andreas, A.
1996-09-24
The National Wind Technology Center (NWTC), located at the foot of the Rocky Mountains near Boulder, Colorado, is a world-class research facility managed by NREL for the U.S. Department of Energy. NWTC researchers work with members of the wind energy industry to advance wind power technologies that lower the cost of wind energy through research and development of state-of-the-art wind turbine designs. NREL's Measurement and Instrument Data Center provides data from NWTC's M2 tower which are derived from instruments mounted on or near an 82 meter (270 foot) meteorological tower located at the western edge of the NWTC site and about 11 km (7 miles) west of Broomfield, and approximately 8 km (5 miles) south of Boulder, Colorado. The data represent the mean value of readings taken every two seconds and averaged over one minute. The wind speed and direction are measured at six heights on the tower and air temperature is measured at three heights. The dew point temperature, relative humidity, barometric pressure, totalized liquid precipitation, and global solar radiation are also available.
Validation of a dew-point generator for pressures up to 6 MPa using nitrogen and air
NASA Astrophysics Data System (ADS)
Bosma, R.; Mutter, D.; Peruzzi, A.
2012-08-01
A new primary humidity standard was developed at VSL that, in addition to ordinary operation with air and nitrogen at atmospheric pressure, can be operated with other carrier gases such as natural gas at pressures up to 6 MPa and SF6 at pressures up to 1 MPa. The temperature range of the standard is from -80 °C to +20 °C. In this paper, we report the validation of the new primary dew-point generator in the temperature range -41 °C to +5 °C and the pressure range 0.1 MPa to 6 MPa using nitrogen and air. For the validation the flow through the dew-point generator was varied up to 10 l min-1 (at 23 °C and 1013 hPa) and the dew point of the gas entering the generator was varied up to 15 °C above the dew point exiting the generator. The validation results showed that the new generator, over the tested temperature and pressure range, can be used with a standard uncertainty of 0.02 °C frost/dew point. The measurements used for the validation at -41 °C and -20 °C with nitrogen and at +5 °C with air were also used to calculate the enhancement factor at pressures up to 6 MPa. For +5 °C the differences between the measured and literature values were compatible with the respective uncertainties. For -41 °C and -20 °C they were compatible only up to 3 MPa. At 6 MPa a discrepancy was observed.
A Summary of Meteorological Parameters During Space Shuttle Pad Exposure Periods
NASA Technical Reports Server (NTRS)
Overbey, Glenn; Roberts, Barry C.
2005-01-01
During the 113 missions of the Space Transportation System (STS), the Space Shuffle fleet has been exposed to the elements on the launch pad for a total of 4195 days. The Natural Environments Branch at Marshall Space Flight Center archives atmospheric environments to which the Space Shuttle vehicles are exposed. This paper provides a summary of the historical record of the meteorological conditions encountered by the Space Shuttle fleet during the pad exposure period. Sources of the surface parameters, including temperature, dew point temperature, relative humidity, wind speed, wind direction, sea level pressure and precipitation are presented. Data is provided from the first launch of the STS in 1981 through the launch of STS-107 in 2003.
Vapor-screen technique for flow visualization in the Langley Unitary Plan Wind Tunnel
NASA Technical Reports Server (NTRS)
Morris, O. A.; Corlett, W. A.; Wassum, D. L.; Babb, C. D.
1985-01-01
The vapor-screen technique for flow visualization, as developed for the Langley Unitary Plan Wind Tunnel, is described with evaluations of light sources and photographic equipment. Test parameters including dew point, pressure, and temperature were varied to determine optimum conditions for obtaining high-quality vapor-screen photographs. The investigation was conducted in the supersonic speed range for Mach numbers from 1.47 to 4.63 at model angles of attack up to 35 deg. Vapor-screen photographs illustrating various flow patterns are presented for several missile and aircraft configurations. Examples of vapor-screen results that have contributed to the understanding of complex flow fields and provided a basis for the development of theoretical codes are presented with reference to other research.
Meteorological conditions during the summer 1986 CITE 2 flight series
NASA Technical Reports Server (NTRS)
Shipham, Mark C.; Cahoon, Donald R.; Bachmeier, A. Scott
1990-01-01
An overview of meteorological conditions during the NASA Global Tropospheric Experiment/Chemical Instrumentation Testing and Evaluation (GTE/CITE 2) summer 1986 flight series is presented. Computer-generated isentropic trajectories are used to trace the history of air masses encountered along each aircraft flight path. The synoptic-scale wind fields are depicted based on Montgomery stream function analyses. Time series of aircraft-measured temperature, dew point, ozone, and altitude are shown to depict air mass variability. Observed differences between maritime tropical and maritime polar air masses are discussed.
1935-2004 Water Vapor Trends at the Summit of Mount Washington, NH
NASA Astrophysics Data System (ADS)
Seidel, T. M.; Grant, A. N.; Pszenny, A. A.
2005-12-01
As part of an ongoing effort to digitize and analyze the unique historical climate record from the summit of Mount Washington, water vapor mixing ratios calculated from synoptic (six-hourly) sling psychrometer and related data will be presented. The Mount Washington Observatory, located at 44°16'N, 71°18'W, 1914 m ASL, has been recording meteorological conditions since 1932. A continuous record of hourly and synoptic data exists from 1935 to the present. Previous work with hourly temperature data has shown an increase in annual temperature of 0.3°C over this 69-year interval, with larger increases during spring and winter, and a decrease in diurnal temperature range (A. Grant et al., J. Climate, in press). Preliminary examination of the synoptic psychrometric data suggests a decrease in annual dew point of approximately 0.4°C, with larger decreases in fall and winter than during the other seasons. Decreasing dew points are expected under two conditions: drier air or constant water vapor with increasing temperature. Other dew point climatologies of the continental United States for the second half of the 20th century have shown mixed results, with increased dew points evident at some stations, decreased dew points at others, and no clear regional patterns.
Physical Patterns Associated with 27 April 2011 Tornado Outbreak
NASA Astrophysics Data System (ADS)
Ramos, Fernanda; Salem, Thomas
2012-02-01
The National Weather Service office in Memphis, Tennessee has aimed their efforts to improve severe tornado forecasting. Everything is not known about tornadogenesis, but one thing is: tornadoes tend to form within supercell thunderstorms. Hence, 27 April 2011 and 25 May 2011 were days when a Tornado Outbreak was expected to arise. Although 22 tornadoes struck the region on 27 April 2011, only 1 impacted the area on 25 May 2011. In order to understand both events, comparisons of their physical features were made. These parameters were studied using the Weather Event Simulator system and the NOAA/NWS Storm Prediction database. This research concentrated on the Surface Frontal Analysis, NAM40 700mb Dew-Points, NAM80 250mb Wind Speed and NAM20 500mb Vorticity images as well as 0-6 km Shear, MUCAPE and VGP mesoscale patterns. As result of this research a Dry-Line ahead of a Cold Front, Dew-points 5C and higher, and high Vorticity values^ were synoptic patterns that influenced to the formation of supercell tornadoes. Finally, MUCAPE and VGP favored the possibility of tornadoes occurrence on 25 May 2011, but shear was the factor that made 27 April 2011 a day for a Tornado Outbreak weather event.
The effects of meteorological factors on the occurrence of Ganoderma sp. spores in the air
NASA Astrophysics Data System (ADS)
Grinn-Gofroń, Agnieszka; Strzelczak, Agnieszka
2011-03-01
Ganoderma sp. is an airborne fungal spore type known to trigger respiratory allergy symptoms in sensitive patients. Aiming to reduce the risk for allergic individuals, we analysed fungal spore circulation in Szczecin, Poland, and its dependence on meteorological conditions. Statistical models for the airborne spore concentrations of Ganoderma sp.—one of the most abundant fungal taxa in the area—were developed. Aerobiological sampling was conducted over 2004-2008 using a volumetric Lanzoni trap. Simultaneously, the following meteorological parameters were recorded: daily level of precipitation, maximum and average wind speed, relative humidity and maximum, minimum, average and dew point temperatures. These data were used as the explaining variables. Due to the non-linearity and non-normality of the data set, the applied modelling techniques were artificial neural networks (ANN) and mutlivariate regression trees (MRT). The obtained classification and MRT models predicted threshold conditions above which Ganoderma sp. appeared in the air. It turned out that dew point temperature was the main factor influencing the presence or absence of Ganoderma sp. spores. Further analysis of spore seasons revealed that the airborne fungal spore concentration depended only slightly on meteorological factors.
Multi-channel fiber optic dew and humidity sensor
NASA Astrophysics Data System (ADS)
Limodehi, Hamid E.; Mozafari, Morteza; Amiri, Hesam; Légaré, François
2018-03-01
In this article, we introduce a multi-channel fiber optic dew and humidity sensor which works using a novel method based on relation between surface plasmon resonance (SPR) and water vapor condensation. The proposed sensor can instantly detect moisture or dew formation through its fiber optic channels, separately situated in different places. It enables to simultaneously measure the ambient Relative Humidity (RH) and dew point temperature of several environments with accuracy of 5%.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 1: January
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of January. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Mean density standard deviation (all for 13 levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
NASA Astrophysics Data System (ADS)
Kraus, Adam H.
Moisture within a transformer's insulation system has been proven to degrade its dielectric strength. When installing a transformer in situ, one method used to calculate the moisture content of the transformer insulation is to measure the dew point temperature of the internal gas volume of the transformer tank. There are two instruments commercially available that are designed for dew point temperature measurement: the Alnor Model 7000 Dewpointer and the Vaisala DRYCAPRTM Hand-Held Dewpoint Meter DM70. Although these instruments perform an identical task, the design technology behind each instrument is vastly different. When the Alnor Dewpointer and Vaisala DM70 instruments are used to measure the dew point of the internal gas volume simultaneously from a pressurized transformer, their differences in dew point measurement have been observed to vary as much as 30 °F. There is minimal scientific research available that focuses on the process of measuring dew point of a gas inside a pressurized transformer, let alone this observed phenomenon. The primary objective of this work was to determine what effect certain factors potentially have on dew point measurements of a transformer's internal gas volume, in hopes of understanding the root cause of this phenomenon. Three factors that were studied include (1) human error, (2) the use of calibrated and out-of-calibration instruments, and (3) the presence of oil vapor gases in the dry air sample, and their subsequent effects on the Q-value of the sampled gas. After completing this portion of testing, none of the selected variables proved to be a direct cause of the observed discrepancies between the two instruments. The secondary objective was to validate the accuracy of each instrument as compared to its respective published range by testing against a known dew point temperature produced by a humidity generator. In a select operating range of -22 °F to -4 °F, both instruments were found to be accurate and within their specified tolerances. This temperature range is frequently encountered in oil-soaked transformers, and demonstrates that both instruments can measure accurately over a limited, yet common, range despite their different design methodologies. It is clear that there is another unknown factor present in oil-soaked transformers that is causing the observed discrepancy between these instruments. Future work will include testing on newly manufactured or rewound transformers in order to investigate other variables that could be causing this discrepancy.
Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis
NASA Technical Reports Server (NTRS)
Arkin, C.; Gillespie, Stacey; Ratzel, Christopher
2010-01-01
A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.
Observation and modelling of urban dew
NASA Astrophysics Data System (ADS)
Richards, Katrina
Despite its relevance to many aspects of urban climate and to several practical questions, urban dew has largely been ignored. Here, simple observations an out-of-doors scale model, and numerical simulation are used to investigate patterns of dewfall and surface moisture (dew + guttation) in urban environments. Observations and modelling were undertaken in Vancouver, B.C., primarily during the summers of 1993 and 1996. Surveys at several scales (0.02-25 km) show that the main controls on dew are weather, location and site configuration (geometry and surface materials). Weather effects are discussed using an empirical factor, FW . Maximum dew accumulation (up to ~ 0.2 mm per night) is seen on nights with moist air and high FW , i.e., cloudless conditions with light winds. Favoured sites are those with high Ysky and surfaces which cool rapidly after sunset, e.g., grass and well insulated roofs. A 1/8-scale model is designed, constructed, and run at an out-of-doors site to study dew patterns in an urban residential landscape which consists of house lots, a street and an open grassed park. The Internal Thermal Mass (ITM) approach is used to scale the thermal inertia of buildings. The model is validated using data from full-scale sites in Vancouver. Patterns in the model agree with those seen at the full-scale, i.e., dew distribution is governed by weather, site geometry and substrate conditions. Correlation is shown between Ysky and surface moisture accumulation. The feasibility of using a numerical model to simulate urban dew is investigated using a modified version of a rural dew model. Results for simple isolated surfaces-a deciduous tree leaf and an asphalt shingle roof-show promise, especially for built surfaces.
Meyer, C W; Hill, K D
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC.
Meyer, C.W.; Hill, K.D.
2015-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952
NASA Astrophysics Data System (ADS)
Golebiowski, Jacek
1995-06-01
The devices to the measurement of air relative humidity with the surface acoustic wave transducers were presented. The relative humidity of air were measured by the determination of the dew point. The results of the investigations that were carried out were described and discussed.
A Calibration Facility for Dew Point in Air up to 1 MPa
NASA Astrophysics Data System (ADS)
Carroll, P. A.; Bell, S. A.; Stevens, M.
2015-12-01
The provision of primary dew-point standards for humidified air and nitrogen at atmospheric pressure is well established, and measurement traceability to these standards provides confidence in a vast number of air humidity measurements. However, hygrometers are used industrially at a wide range of pressures. Both the performance of hygrometers and the properties of humid gases are known to vary with gas pressure. The pressure-dependence of gas non-ideality for air-water mixtures (water-vapor enhancement factor) is well enough known at moderate pressures, but there remains a need to characterize hygrometers at the pressure of use. To address this, a humidity calibration capability of wider scope is under development at the UK National Physical Laboratory (NPL). As an initial stage in the development of this capability, a humidity standard generating air or nitrogen in the dew-point range from -60° C to +10° C, at pressures up to 1 MPa (10 bar) has been validated for the calibration of hygrometers. The expanded uncertainty of the dew-point generator in this range with a coverage factor k= 2 is ± 0.07° C.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 7: July
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of July. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 10: October
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of October. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point/standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 3: March
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-11-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of March. Included are global analyses of: (1) Mean Temperature Standard Deviation; (2) Mean Geopotential Height Standard Deviation; (3) Mean Density Standard Deviation; (4) Height and Vector Standard Deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean Dew Point Standard Deviation for levels 1000 through 30 mb; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 2: February
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-09-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of February. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 4: April
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of April. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Laureano-Rosario, Abdiel E; Symonds, Erin M; Rueda-Roa, Digna; Otis, Daniel; Muller-Karger, Frank E
2017-12-19
Enterococci concentration variability at Escambron Beach, San Juan, Puerto Rico, was examined in the context of environmental conditions observed during 2005-2015. Satellite-derived sea surface temperature (SST), turbidity, direct normal irradiance, and dew point were combined with local precipitation, winds, and mean sea level (MSL) observations in a stepwise multiple regression analyses (Akaike Information Criteria model selection). Precipitation, MSL, irradiance, SST, and turbidity explained 20% of the variation in observed enterococci concentrations based upon these analyses. Changes in these parameters preceded increases in enterococci concentrations by 24 h up to 11 days, particularly during positive anomalies of turbidity, SST, and 480-960 mm of accumulated (4 days) precipitation, which relates to bacterial ecology. Weaker, yet still significant, increases in enterococci concentrations were also observed during positive dew point anomalies. Enterococci concentrations decreased with elevated irradiance and MSL anomalies. Unsafe enterococci concentrations per US EPA recreational water quality guidelines occurred when 4-day cumulative precipitation ranged 481-960 mm; irradiance < 667 W·m -2 ; daily average turbidity anomaly >0.005 sr -1 ; SST anomaly >0.8 °C; and 3-day average MSL anomaly <-18.8 cm. This case study shows that satellite-derived environmental data can be used to inform future water quality studies and protect human health.
Characterization of canopy dew formation in tropical forests using active microwave remote sensing
NASA Astrophysics Data System (ADS)
Gerlein-Safdi, C.; Frolking, S. E.; Caylor, K. K.
2016-12-01
Dew deposition in a closed canopy is thought to be greatest on top of the canopy, since a clear view of the sky increases condensation. In tropical forests, these same leaves are also subject to direct sunlight and high transpiration rates. Dew deposition can offset some of the water stress through foliar uptake of the dew droplets, or transpiration suppression from the energy dissipation associated with dew evaporation. However, the long-term trends of dew formation and their global patterns have received little attention, despite the wide acknowledgement that non-meteoric water can be a key source of water for many species, especially in tropical ecosystems. As such, accumulated and future effects of climate change on non-meteoric water occurrence remain an under-appreciated and unquantified factor in determining the risks that tropical ecosystems face. In this presentation, we simulate the effects of a wet canopy on satellite-based microwave backscatter by modifying the Michigan Microwave Canopy Scattering Model to account for the presence of dew droplets. We apply this model to estimate the canopy water storage derived from the SeaWinds Scatterometer aboard the QuikSCAT satellite by comparing the 6AM and 6PM microwave retrievals. We examine dew frequency and amount in tropical forests in South America, Africa and South-East Asia. Using the 10 years of available data, we investigate trends in dew formation in these three areas and speculate on the potential impact of the observed changes on dew-dependent tropical ecosystems.Finally, we compare our results to locally measured and modeled leaf wetness data. With multiple recently-launched instruments providing new data, strong correlations between satellite-based canopy water storage and in-situ data indicate the possibility of novel applications of microwave backscatter datasets in closed canopies ecosystems, such as the estimation of canopy interception or leaf-water content.
Effects of meteorological conditions on spore plumes
NASA Astrophysics Data System (ADS)
Burch, M.; Levetin, E.
2002-05-01
Fungal spores are an ever-present component of the atmosphere, and have long been known to trigger asthma and hay fever symptoms in sensitive individuals. The atmosphere around Tulsa has been monitored for airborne spores and pollen with Burkard spore traps at several sampling stations. This study involved the examination of the hourly spore concentrations on days that had average daily concentrations near 50,000 spores/m3 or greater. Hourly concentrations of Cladosporium, Alternaria, Epicoccum, Curvularia, Pithomyces, Drechslera, smut spores, ascospores, basidiospores, other, and total spores were determined on 4 days at three sites and then correlated with hourly meteorological data including temperature, rainfall, wind speed, dew point, air pressure, and wind direction. On each of these days there was a spore plume, a phenomenon in which spore concentrations increased dramatically over a very short period of time. Spore plumes generally occurred near midday, and concentrations were seen to increase from lows around 20,000 total spores/m3 to highs over 170,000 total spores/m3 in 2 h. Multiple regression analysis of the data indicated that increases in temperature, dew point, and air pressure correlated with the increase in spore concentrations, but no single weather variable predicted the appearance of a spore plume. The proper combination of changes in these meteorological parameters that result in a spore plume may be due to the changing weather conditions associated with thunderstorms, as on 3 of the 4 days when spore plumes occurred there were thunderstorms later that evening. The occurrence of spore plumes may have clinical significance, because other studies have shown that sensitization to certain spore types can occur during exposure to high spore concentrations.
Atmospheric moisture's influence on fire behavior: surface moisture and plume dynamics.
Brian E. Potter; Joseph J. Charney; Lesley A. Fusina
2006-01-01
Nine measures of atmospheric surface moisture are tested for statistical relationships with fire size and number of fires using data from the Great Lakes region of the United States. The measures include relative humidity, water vapor mixing ratio, mixing ratio deficit, vapor pressure, vapor pressure deficit, dew point temperature, dew point depression, wet bulb...
Sensitive skin at menopause; dew point and electrometric properties of the stratum corneum.
Paquet, F; Piérard-Franchimont, C; Fumal, I; Goffin, V; Paye, M; Piérard, G E
1998-01-12
A number of menopausal women experience skin sensitive to various environmental threats. Two panels of 15 menopausal women on or without HRT were compared. We studied the response of their stratum corneum to variations in environmental humidity, either in air or in response to an emollient. Environment dew point and electrometric measurements on the skin were recorded to search for correlations. Data show that the baseline stratum corneum hydration is influenced by the dew point. HRT improves the barrier function of the skin. The use of emollient further extends the improvement in the functional properties of skin in menopausal women. Both HRT and an emollient can counteract in part some of the deleterious effects of cold and dry weather.
Nighttime water absorption by a bare loess soil in a coastal desert
NASA Astrophysics Data System (ADS)
Ninari, N.; Berliner, P. R.
2003-04-01
The role of dew in arid and semi-arid ecosystems is considered to be of great importance. It can serve as a water source for the bacteria of biological crust, for plants and for small insects. The Negev Desert is a semiarid region characterized by winter rainfall with a very large inter-annual variability. Reports on measurements carried out in this area mention that up to 180 nights a year with dew were registered by a conventional Hiltner Dew Balance, with intensities that ranged from 0.1 to 0.2 mm per night (yielding a total of 15 mm per year, which is more than 10% of the total rainfall). The Hiltner dew balance is based on the continuous weighing of an artificial condensation plate that has a completely different energy balance from that of the soil surface above which it is installed. The Hiltner dew balance could, therefore, be considered as a ``potential dew" gauge, whose results are probably mainly correlated to atmospheric conditions. The prime objective of this work was, therefore, to quantify the amounts of dew deposition on the soil surface, and to compare these amounts to those measured by the Hiltner balance. Measurements were carried out at the Wadi Mashash Experimental Farm in the Negev. To estimate deposition and evaporation of dew, a micro-lysimeter (diameter: 20 cm; soil depth: 50 cm) with an undisturbed soil sample was installed flush with the soil surface. The following were continuously monitored: micro-lysimeter weight, incoming and reflected short wave radiation, net radiation, dry and wet bulb temperatures, wind speed, and soil heat flux. A Hiltner Dew Balance was placed close by as a reference to compare with previous measurements. Throughout the ``dew period" (spring, summer and fall), and at random intervals, soil samples were taken hourly during the whole night. The uppermost 10 cm of the soil was divided into 1 cm intervals, and the soil moisture content was measured (oven dry). During the above-mentioned night campaigns, no dew deposition could be visually detected on the soil surface. A mass gain was however registered with the ML and an increase in moisture content was observed. The Hiltner balance clearly underestimated dew deposition amounts. These results indicate that although no visual signs of dew deposition could be detected, moisture did penetrate into the soil.
Jumping-Droplet Condensation Drives Pathogen Transport on Wheat Leaves
NASA Astrophysics Data System (ADS)
Nath, Saurabh; Gruszewski, Hope; Budhiraja, Stuti; Ahmadi, Farzad; Bisbano, Caitlin; Jung, Sunghwan; Schmale, David, III; Boreyko, Jonathan
2017-11-01
The classical viewpoint in phytopathology regarding how plant pathogens are liberated is based on active mechanisms such as shearing off spores via rain splash or wind. All of these mechanisms require some kind of impact on the surface. Here we show for the first time that there exists an entirely different mechanism in nature that drives pathogen transport on wheat leaves. Wheat leaves are inherently superhydrophobic, which enables microscopic dew droplets to spontaneously jump off the leaf surface during natural condensation cycles. We found that black rust (Puccinia graminis) spores often adhere to such coalescence-induced self-propelled dew droplets and subsequently get transported vertically as high as 5 mm. Once pathogens clear the quiescent boundary layer, typically of order 1 mm, they have the potential to be dispersed over large distances by the aid of atmospheric flows. A custom-made experimental set-up was devised to simulate multiple one hour long natural dew cycles and how they affect spore dispersal. Spore liberation rates via jumping-droplet condensation were found to be as high 100 spores/cm2-hr. These findings reveal that on a sufficiently non-wetting surface humidity alone can liberate fungal spores, adding it as a third mechanism besides wind and rain.
Dew and hoarfrost frequency, formation efficiency and chemistry in Wroclaw, Poland
NASA Astrophysics Data System (ADS)
Gałek, G.; Sobik, M.; Błaś, M.; Polkowska, Ż.; Cichała-Kamrowska, K.; Wałaszek, K.
2015-01-01
This article presents the results of a research study concerning a comparison of frequency, formation efficiency and basic physico-chemical properties of dew and hoarfrost in urban conditions. Longer than two-year series of measurements was carried out from 1 February 2008 to 10 March 2010 in Wroclaw, Poland. Sampling of atmospheric deposits was made by means of insulated plain passive radiative condensers, which allowed to collect 222 dew and 96 hoarfrost samples. The results indicate that the frequency of dew days was about threefold greater than hoarfrost days. The formation efficiency of both types of deposits was almost the same, and reached a mean value of about 100 mL·m- 2 per day. The conducted analysis of several meteorological parameters showed that dew and hoarfrost, despite seasonal weather changes, were formed in very similar meteorological conditions. Only water vapor pressure values were in average twice higher in the case of dew and the impact of this parameter on dew and hoarfrost formation efficiency seems to be more complex than expected. The role of night duration in counterbalancing of smaller amount of available moisture in hoarfrost days is not clear. The investigation showed also, that there was an expected clear positive dependence of dew and hoarfrost formation efficiency on relative humidity, and not so evident in the case of temperature inversion, and wind velocity. The physico-chemical analysis indicated that the pH of dew was only slightly lower than the hoarfrost ones, regardless of the deposit formation intensity. Simultaneously, the lower pH values were much more frequent in the case of dew, which resulted from more effective absorption of anthropogenic NO3- and SO42 - ions. For both types of deposits, the average pH was low (4.5-4.8) in relation to majority of studies reported in literature. In spite of seasonal changes of pollutant concentration, various weather conditions and different mechanisms of pollutant absorption of dew and hoarfrost were characterized with almost identical, relatively low contamination - electric conductivity: 42 μS·cm- 1. The dominant ions were: Ca2 +, SO42 -, NO3-, as well as Cl- (hoarfrost only), all of them predominantly of anthropogenic origin.
NASA Astrophysics Data System (ADS)
Vilbaste, M.; Heinonen, M.; Saks, O.; Leito, I.
2013-08-01
The purpose of this paper is to study the effect of contaminated water in the context of humidity generators. Investigation of different methods to determine the drop in dew-point temperature due to contamination and experiments on actual contamination rates are reported. Different methods for calculating the dew-point temperature effect from electrical conductivity and density measurements are studied with high-purity water and aqueous solutions of NaCl and LiCl. The outcomes of the calculation methods are compared with the results of direct humidity measurements. The results show that the often applied Raoult's law based calculation method is in good agreement with other methods. For studying actual contamination, water samples were kept in glass, plastic, copper and stainless-steel vessels for up to 13 months to investigate natural ionic and organic contamination in vessels with different wall materials. The amount of ionic contamination was found to be higher in copper and glass vessels than in stainless-steel and plastic vessels. The amount of organic contamination was found to be highest in the plastic vessel. In all the cases, however, the corresponding drop in dew-point temperature due to natural contamination was found to be below 0.1 mK. The largest rate of change of dew-point temperature was 26 µK/month. Thus, if proper cleanness is maintained in a humidity generator the effect of contamination of water in the saturator is insignificant compared with the major uncertainty components even in the most accurate generators today.
Integrated CMOS dew point sensors for relative humidity measurement
NASA Astrophysics Data System (ADS)
Savalli, Nicolo; Baglio, Salvatore; Castorina, Salvatore; Sacco, Vincenzo; Tringali, Cristina
2004-07-01
This work deals with the development of integrated relative humidity dew point sensors realized by adopting standard CMOS technology for applications in various fields. The proposed system is composed by a suspended plate that is cooled by exploiting integrated Peltier cells. The cold junctions of the cells have been spread over the plate surface to improve the homogeneity of the temperature distribution over its surface, where cooling will cause the water condensation. The temperature at which water drops occur, named dew point temperature, is a function of the air humidity. Measurement of such dew point temperature and the ambient temperature allows to know the relative humidity. The detection of water drops is achieved by adopting a capacitive sensing strategy realized by interdigited fixed combs, composed by the upper layer of the adopted process. Such a capacitive sensor, together with its conditioning circuit, drives a trigger that stops the cooling of the plate and enables the reading of the dew point temperature. Temperature measurements are achieved by means of suitably integrated thermocouples. The analytical model of the proposed system has been developed and has been used to design a prototype device and to estimate its performances. In such a prototype, the thermoelectric cooler is composed by 56 Peltier cells, made by metal 1/poly 1 junctions. The plate has a square shape with 200 μm side, and it is realized by exploiting the oxide layers. Starting from the ambient temperature a temperature variation of ΔT = 15 K can be reached in 10 ms thus allowing to measure a relative humidity greater than 40%.
Smart textile plasmonic fiber dew sensors.
Esmaeilzadeh, Hamid; Rivard, Maxime; Arzi, Ezatollah; Légaré, François; Hassani, Alireza
2015-06-01
We propose a novel Surface Plasmon Resonance (SPR)-based sensor that detects dew formation in optical fiber-based smart textiles. The proposed SPR sensor facilitates the observation of two phenomena: condensation of moisture and evaporation of water molecules in air. This sensor detects dew formation in less than 0.25 s, and determines dew point temperature with an accuracy of 4%. It can be used to monitor water layer depth changes during dew formation and evaporation in the range of a plasmon depth probe, i.e., 250 nm, with a resolution of 7 nm. Further, it facilitates estimation of the relative humidity of a medium over a dynamic range of 30% to 70% by measuring the evaporation time via the plasmon depth probe.
A microwave resonance dew-point hygrometer
NASA Astrophysics Data System (ADS)
Underwood, R. J.; Cuccaro, R.; Bell, S.; Gavioso, R. M.; Madonna Ripa, D.; Stevens, M.; de Podesta, M.
2012-08-01
We report the first measurements of a quasi-spherical microwave resonator used as a dew-point hygrometer. In conventional dew-point hygrometers, the condensation of water from humid gas flowing over a mirror is detected optically, and the mirror surface is then temperature-controlled to yield a stable condensed layer. In our experiments we flowed moist air from a humidity generator through a quasi-spherical resonator and detected the onset of condensation by measuring the frequency ratio of selected microwave modes. We verified the basic operation of the device over the dew-point range 9.5-13.5 °C by comparison with calibrated chilled-mirror hygrometers. These tests indicate that the microwave method may allow a quantitative estimation of the volume and thickness of the water layer which is condensed on the inner surface of the resonator. The experiments reported here are preliminary due to the limited time available for the work, but show the potential of the method for detecting not only water but a variety of other liquid or solid condensates. The robust all-metal construction should make the device appropriate for use in industrial applications over a wide range of temperatures and pressures.
NASA Astrophysics Data System (ADS)
Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.
2015-01-01
A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Paredes, P.; Fontes, J. C.; Azevedo, E. B.; Pereira, L. S.
2017-11-01
Reference crop evapotranspiration (ETo) estimations using the FAO Penman-Monteith equation (PM-ETo) require a set of weather data including maximum and minimum air temperatures (T max, T min), actual vapor pressure (e a), solar radiation (R s), and wind speed (u 2). However, those data are often not available, or data sets are incomplete due to missing values. A set of procedures were proposed in FAO56 (Allen et al. 1998) to overcome these limitations, and which accuracy for estimating daily ETo in the humid climate of Azores islands is assessed in this study. Results show that after locally and seasonally calibrating the temperature adjustment factor a d used for dew point temperature (T dew) computation from mean temperature, ETo estimations shown small bias and small RMSE ranging from 0.15 to 0.53 mm day-1. When R s data are missing, their estimation from the temperature difference (T max-T min), using a locally and seasonal calibrated radiation adjustment coefficient (k Rs), yielded highly accurate ETo estimates, with RMSE averaging 0.41 mm day-1 and ranging from 0.33 to 0.58 mm day-1. If wind speed observations are missing, the use of the default u 2 = 2 m s-1, or 3 m s-1 in case of weather measurements over clipped grass in airports, revealed appropriated even for the windy locations (u 2 > 4 m s-1), with RMSE < 0.36 mm day-1. The appropriateness of procedure to estimating the missing values of e a, R s, and u 2 was confirmed.
Park, Dae-Heon; Park, Jang-Woo
2011-01-01
Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop’s surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control. PMID:22163813
Park, Dae-Heon; Park, Jang-Woo
2011-01-01
Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop's surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control.
Meyer, C W; Solano, A
2016-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.
Meyer, C.W.; Solano, A.
2016-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029
NASA Astrophysics Data System (ADS)
Lenderink, Geert; Barbero, Renaud; Loriaux, Jessica; Fowler, Hayley
2017-04-01
Present-day precipitation-temperature scaling relations indicate that hourly precipitation extremes may have a response to warming exceeding the Clausius-Clapeyron (CC) relation; for The Netherlands the dependency on surface dew point temperature follows two times the CC relation corresponding to 14 % per degree. Our hypothesis - as supported by a simple physical argument presented here - is that this 2CC behaviour arises from the physics of convective clouds. So, we think that this response is due to local feedbacks related to the convective activity, while other large scale atmospheric forcing conditions remain similar except for the higher temperature (approximately uniform warming with height) and absolute humidity (corresponding to the assumption of unchanged relative humidity). To test this hypothesis, we analysed the large-scale atmospheric conditions accompanying summertime afternoon precipitation events using surface observations combined with a regional re-analysis for the data in The Netherlands. Events are precipitation measurements clustered in time and space derived from approximately 30 automatic weather stations. The hourly peak intensities of these events again reveal a 2CC scaling with the surface dew point temperature. The temperature excess of moist updrafts initialized at the surface and the maximum cloud depth are clear functions of surface dew point temperature, confirming the key role of surface humidity on convective activity. Almost no differences in relative humidity and the dry temperature lapse rate were found across the dew point temperature range, supporting our theory that 2CC scaling is mainly due to the response of convection to increases in near surface humidity, while other atmospheric conditions remain similar. Additionally, hourly precipitation extremes are on average accompanied by substantial large-scale upward motions and therefore large-scale moisture convergence, which appears to accelerate with surface dew point. This increase in large-scale moisture convergence appears to be consequence of latent heat release due to the convective activity as estimated from the quasi-geostrophic omega equation. Consequently, most hourly extremes occur in precipitation events with considerable spatial extent. Importantly, this event size appears to increase rapidly at the highest dew point temperature range, suggesting potentially strong impacts of climatic warming.
Observed changes in relative humidity and dew point temperature in coastal regions of Iran
NASA Astrophysics Data System (ADS)
Hosseinzadeh Talaee, P.; Sabziparvar, A. A.; Tabari, Hossein
2012-12-01
The analysis of trends in hydroclimatic parameters and assessment of their statistical significance have recently received a great concern to clarify whether or not there is an obvious climate change. In the current study, parametric linear regression and nonparametric Mann-Kendall tests were applied for detecting annual and seasonal trends in the relative humidity (RH) and dew point temperature ( T dew) time series at ten coastal weather stations in Iran during 1966-2005. The serial structure of the data was considered, and the significant serial correlations were eliminated using the trend-free pre-whitening method. The results showed that annual RH increased by 1.03 and 0.28 %/decade at the northern and southern coastal regions of the country, respectively, while annual T dew increased by 0.29 and 0.15°C per decade at the northern and southern regions, respectively. The significant trends were frequent in the T dew series, but they were observed only at 2 out of the 50 RH series. The results showed that the difference between the results of the parametric and nonparametric tests was small, although the parametric test detected larger significant trends in the RH and T dew time series. Furthermore, the differences between the results of the trend tests were not related to the normality of the statistical distribution.
Development of a Dew-Point Generator for Gases Other than Air and Nitrogen and Pressures up to 6 MPa
NASA Astrophysics Data System (ADS)
Bosma, R.; Peruzzi, A.
2012-09-01
A new primary humidity standard is currently being developed at VSL that, in addition to ordinary operation with air and nitrogen at atmospheric pressure, can be operated also with special carrier gases such as natural gas and SF6 and at pressures up to 6 MPa. In this paper, the design and construction of this new primary dew-point generator and the preliminary tests performed on the generator are reported. The results of the first efficiency tests, performed for the dew-point temperature range from -50 °C to 20°C, for pressures up to 0.7MPa and for carrier gas flow rates up to 4L· min-1, showed satisfactory generator performance when used in the single-pass mode, i.e., with no recirculation of the carrier gas.
Rueda-Roa, Digna; Otis, Daniel; Muller-Karger, Frank E.
2017-01-01
Enterococci concentration variability at Escambron Beach, San Juan, Puerto Rico, was examined in the context of environmental conditions observed during 2005–2015. Satellite-derived sea surface temperature (SST), turbidity, direct normal irradiance, and dew point were combined with local precipitation, winds, and mean sea level (MSL) observations in a stepwise multiple regression analyses (Akaike Information Criteria model selection). Precipitation, MSL, irradiance, SST, and turbidity explained 20% of the variation in observed enterococci concentrations based upon these analyses. Changes in these parameters preceded increases in enterococci concentrations by 24 h up to 11 days, particularly during positive anomalies of turbidity, SST, and 480–960 mm of accumulated (4 days) precipitation, which relates to bacterial ecology. Weaker, yet still significant, increases in enterococci concentrations were also observed during positive dew point anomalies. Enterococci concentrations decreased with elevated irradiance and MSL anomalies. Unsafe enterococci concentrations per US EPA recreational water quality guidelines occurred when 4-day cumulative precipitation ranged 481–960 mm; irradiance < 667 W·m−2; daily average turbidity anomaly >0.005 sr−1; SST anomaly >0.8 °C; and 3-day average MSL anomaly <−18.8 cm. This case study shows that satellite-derived environmental data can be used to inform future water quality studies and protect human health. PMID:29257092
Inventory of File nam.t00z.smartconus06.tm00.grib2
Temperature [K] 002 surface DPT 6 hour fcst Dew Point Temperature [K] 003 surface SPFH 6 hour fcst Specific Index [K] 027 surface HINDEX 6 hour fcst Haines Index [Numeric] 028 surface TMP 5 hour fcst Temperature [K] 029 surface TMP 4 hour fcst Temperature [K] 030 surface DPT 5 hour fcst Dew Point Temperature [K
Inventory of File gfs.t06z.smartguam12.tm00.grib2
Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific Best (4 layer) Lifted Index [K] 020 surface TMP 11 hour fcst Temperature [K] 021 surface TMP 10 hour fcst Temperature [K] 022 surface DPT 11 hour fcst Dew Point Temperature [K] 023 surface DPT 10 hour
Inventory of File nam.t00z.smartconus12.tm00.grib2
Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific hour fcst Haines Index [Numeric] 030 surface TMP 11 hour fcst Temperature [K] 031 surface TMP 10 hour fcst Temperature [K] 032 surface DPT 11 hour fcst Dew Point Temperature [K] 033 surface DPT 10 hour
NASA Astrophysics Data System (ADS)
Okjeong, Lee; Sangdan, Kim
2016-04-01
According to future climate change scenarios, future temperature is expected to increase gradually. Therefore, it is necessary to reflect the effects of these climate changes to predict Probable Maximum Precipitations (PMPs). In this presentation, PMPs will be estimated with future dew point temperature change. After selecting 174 major storm events from 1981 to 2005, new PMPs will be proposed with respect to storm areas (25, 100, 225, 400, 900, 2,025, 4,900, 10,000 and 19,600 km2) and storm durations (1, 2, 4, 6, 8, 12, 18, 24, 48 and 72 hours) using the Korea hydro-meteorological method. Also, orographic transposition factor will be applied in place of the conventional terrain impact factor which has been used in previous Korean PMPs estimation reports. After estimating dew point temperature using future temperature and representative humidity information under the Korea Meteorological Administration AR5 RCP 8.5, changes in the PMPs under dew point temperature change will be investigated by comparison with present and future PMPs.
Inventory of File gfs.t06z.smartguam03.tm00.grib2
Temperature [K] 002 surface DPT 3 hour fcst Dew Point Temperature [K] 003 surface SPFH 3 hour fcst Specific surface 4LFTX 3 hour fcst Best (4 layer) Lifted Index [K] 019 surface TMP 2 hour fcst Temperature [K] 020 surface TMP 1 hour fcst Temperature [K] 021 surface DPT 2 hour fcst Dew Point Temperature [K] 022 surface
NASA Technical Reports Server (NTRS)
Fishman, Jack; Gregory, Gerald L.; Sachse, Glen W.; Beck, Sherwin M.; Hill, Gerald F.
1987-01-01
A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.
Variational analysis of temperature and moisture advection in a severe storm environment
NASA Technical Reports Server (NTRS)
Mcfarland, M. J.; Sasaki, Y. K.
1977-01-01
Horizontal wind components, potential temperature, and mixing ratio fields associated with a severe storm environment in the south central United States were objectively analyzed from synoptic upper air observations with a nonhomogeneous anisotropic weighting function. The particular case study discussed here is the tornado producting squall line which moved through eastern Oklahoma 26 May 1973. The synoptic situation which preceded squall line development was cyclogenesis and frontogenesis in the lee-of-mountain trough, which produced a well-defined surface dry line (or dew point front) and a pronounced mid-level dry air intrusion. It is shown that the intrusion was also characterized by warm air, with a lapse rate approaching the dry adiabatic.
2013-03-21
and timers use a time-based estimate to predict how many people are in a facility at a given point in the day. CO2-based DCV systems measure CO2...energy and latent energy from the outside air when the coils’ surface temperature is below the dew point of the air passing over the coils (ASHRAE...model assumes that the dew point water saturation pressure is the same as the dry-bulb water vapor pressure, consistent with a typical ASHRAE
On the contribution of atmospheric moisture to dew formation
NASA Astrophysics Data System (ADS)
Garratt, J. R.; Segal, M.
1988-09-01
The relative contributions of dewfall (a flux of water vapour from air to surface) and distillation (a flux of water vapour from soil to canopy) to dew formation on closed canopy and bare soil surfaces are assessed, and the dependence of dew amount upon wind speed, absolute temperature, atmospheric stability, relative humidity, soil characteristics and cloudiness, all of which are significant factors, is evaluated. Some of these evaluations provide refinements to similar ones given in Monteith (1961). High dewfall rates are usually ≲0.06 mm hr-1 over canopy or bare soil, though upon a canopy under soil-saturated and air-saturated conditions, rates of dew formation may reach 0.07 0.09 mm hr-1 with contributions from distillation. Various sets of observations are reanalyzed to illustrate the importance of the horizontal advection of moisture in the nocturnal boundary layer (NBL) to observed high rates of dew formation arising from the atmospheric contribution of water vapour (dewfall). These locally observed high dewfall rates must be the result of small-scale or mesoscale horizontal advection of moisture in the NBL, since the humidity changes within the typically shallow NBL required to balance the loss of water at the surface are not observed. Over extensive areas of uniform surface (horizontal scales ≫10 km), such continuously high dewfall rates could only be balanced by a local supply of atmospheric moisture since advection of moisture would necessarily be small.
1981-01-14
wet-bulb temperature depression versus dry -bulb temperature, means and standard deviations of d-j-bulb, wet-bulb (over) SDD, 1473 UNCLASS IF I ED FC...distribution tables Dry -bulb temperature versud wet-bulb temperature Cumulative percentage frequency of distribution tables 20. and dew point...PART 5 PRECIPITATION PSYCHROMETRIC.DRY VS WET BULB SNOWFALL MEAN & STO 0EV SNOW EPTH DRY BULB, WET BULB, &DEW POINtI RELATIVE HUMIDITY PARTC SURFACE
[An automatic dew-point hygrometer making use of beta-ray backscattering (author's transl)].
Matsumoto, S; Kobayashi, H
1981-04-01
A proportional control system was employed on this hygrometer. The hygrometer was used in a box in which the temperature and the humidity were constantly regulated. The range of measured dew-point was from -26 degrees C to 60 degrees C in the atmospheric temperature of 0 degree C to 60 degrees C, that was the relative humidity of 12% to 100%, and the accuracy of the measurement was +/- 1 degree C.
Extreme precipitation response to climate perturbations in an atmospheric mesoscale model
NASA Astrophysics Data System (ADS)
Attema, Jisk J.; Loriaux, Jessica M.; Lenderink, Geert
2014-01-01
Observations of extreme (sub-)hourly precipitation at mid-latitudes show a large dependency on the dew point temperature often close to 14% per degree—2 times the dependency of the specific humidity on dew point temperature which is given by the Clausius-Clapeyron (CC) relation. By simulating a selection of 11 cases over the Netherlands characterized by intense showers, we investigate this behavior in the non-hydrostatic weather prediction model Harmonie at a resolution of 2.5 km. These experiments are repeated using perturbations of the atmospheric profiles of temperature and humidity: (i) using an idealized approach with a 2° warmer (colder) atmosphere assuming constant relative humidity, and (ii) using changes in temperature and humidity derived from a long climate change simulation at 2° global warming. All perturbations have a difference in the local dew point temperature compared to the reference of approximately 2°. Differences are considerable between the cases, with dependencies ranging from almost zero to an increase of 18% per degree rise of the dew point temperature. On average however, we find an increase of extreme precipitation intensity of 11% per degree for the idealized perturbation, and 9% per degree for the climate change perturbation. For the most extreme events these dependencies appear to approach a rate of 11-14% per degree, in closer agreement with the observed relation.
Dew-point hygrometry system for measurement of evaporative water loss in infants.
Ariagno, R L; Glotzbach, S F; Baldwin, R B; Rector, D M; Bowley, S M; Moffat, R J
1997-03-01
Evaporation of water from the skin is an important mechanism in thermal homeostasis. Resistance hygrometry, in which the water vapor pressure gradient above the skin surface is calculated, has been the measurement method of choice in the majority of pediatric investigations. However, resistance hygrometry is influenced by changes in ambient conditions such as relative humidity, surface temperature, and convection currents. We have developed a ventilated capsule method that minimized these potential sources of measurement error and that allowed second-by-second, long-term, continuous measurements of evaporative water loss in sleeping infants. Air with a controlled reference humidity (dew-point temperature = 0 degree C) is delivered to a small, lightweight skin capsule and mixed with the vapor on the surface of the skin. The dew point of the resulting mixture is measured by using a chilled mirror dew-point hygrometer. The system indicates leaks, is mobile, and is accurate within 2%, as determined by gravimetric calibration. Examples from a recording of a 13-wk-old full-term infant obtained by using the system give evaporative water loss rates of approximately 0.02 mgH2O.cm-2.min-1 for normothermic baseline conditions and values up to 0.4 mgH2O.cm-2. min-1 when the subject was being warmed. The system is effective for clinical investigations that require dynamic measurements of water loss.
2010-12-01
INTRODUCTION ............................................1 A. DIRECTED ENERGY WEAPONS ( DEW ) ......................1 B. FREE ELECTRON LASER (FEL...WEAPONS (C- DEW ) ............7 1. Navy Relevance ................................7 2. Problem Description ...........................7 II...invisibility cloaks from [9].................................18 Figure 7. Simple cubic lattice of points in co-coordinate system (left) maps into a
Effects of environmental factors on monuments: the Harkhuf Tomb in Aswan, Egypt
NASA Astrophysics Data System (ADS)
Baldi, Marina
2015-04-01
The tombs of the nobles excavated in the rocks on the Nile west bank at Qubbet el-Hawa in Aswan (Egypt) testify the role of the city as the southern gate of Egypt. In old times Aswan was the starting point of caravans travelling far south in uncovered territories and bringing back precious and exotic goods. Inscriptions on the tombs reflect the explorations and trades of that time and the cultural exchanges with southern territories. Nowadays the tombs, exposed to the environmental factors - wind, sun, rainfall - and to air polluttants originated from the town of Aswan are under a fast deterioration process. It is therefore necessary a full documentation of the tombs and of their façade and a study of the deterioration process due to the impact of the environmental factors. As a case study the tomb of Harkhuf at Qubbet el-Hawa has been chosen, because of its importance, its status of decay, and for the old documentation by the Italian Egyptologist E. Schiaparelli. The climate factors affecting the tomb of Harkhuf are air temperature, its diurnal excursion, and wind, and, at some extent, relative humidity. In fact, in Aswan, night time Humidity can be more than 30% during the winter months, while precipitation is a very rare event occurring once every 1 or 2 years, but has important impact due to its high intensity and short duration with devastating impact on manufact and structures in the area. The experiment, designed using portable meteorological instruments, permitted to define if the microclimate near the Harkhuf Tomb has the same characteristics of the larger Aswan area which can be derived by the meteorological station located at the Aswan airport. However differences in the microclimate are evident and preliminary analysis of data collected between 8:00 am and 4:00 pm during some consecutive days will be presented. The study permitted to identify and measure the differential heating of the façade, with the right part reaching temperatures much warmer than the left and for a longer period, being under the direct sunrays for a longer period. In the interior, during the day, the temperature excursion is much more moderate, but some dew formation has been observed which contributes to the mold formation in parts of the walls of the tumb. In addition, some measurements of wind intensity and direction show a persistent wind blowing from N-NE starting mid-morning, around 10:30 am until late afternoon. In particular, the observations permitted: > to understand if the different parts of the façade of the tomb are under the influence of physical stress of different intensity due to the temperature gradient detected along the façade itself; > to determine if and in which conditions the temperatures excursion together with the right level of relative humidity of the air favor the formation of dew at dawn and of high dew point values. This study is part of the multidisciplinary project TECH (Technologies for the Egyptian Cultural Heritage) funded by the National Reserach Council of Italy and by the Academy of Scientific Research and Technology of Egypt (ASRT).
Estimation of precipitable water at different locations using surface dew-point
NASA Astrophysics Data System (ADS)
Abdel Wahab, M.; Sharif, T. A.
1995-09-01
The Reitan (1963) regression equation of the form ln w = a + bT d has been examined and tested to estimate precipitable water vapor content from the surface dew point temperature at different locations. The results of this study indicate that the slope b of the above equation has a constant value of 0.0681, while the intercept a changes rapidly with latitude. The use of the variable intercept technique can improve the estimated result by about 2%.
Dew inspired breathing-based detection of genetic point mutation visualized by naked eye
Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan
2014-01-01
A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions. PMID:25199907
Dew inspired breathing-based detection of genetic point mutation visualized by naked eye
NASA Astrophysics Data System (ADS)
Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan
2014-09-01
A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.
Dew inspired breathing-based detection of genetic point mutation visualized by naked eye.
Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan
2014-09-09
A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.
Xue, Dan; Yin, Jingyuan
2014-05-01
In this study, we explored the potential applications of the Ozone Monitoring Instrument (OMI) satellite sensor in air pollution research. The OMI planetary boundary layer sulfur dioxide (SO2_PBL) column density and daily average surface SO2 concentration of Shanghai from 2004 to 2012 were analyzed. After several consecutive years of increase, the surface SO2 concentration finally declined in 2007. It was higher in winter than in other seasons. The coefficient between daily average surface SO2 concentration and SO2_PBL was only 0.316. But SO2_PBL was found to be a highly significant predictor of the surface SO2 concentration using the simple regression model. Five meteorological factors were considered in this study, among them, temperature, dew point, relative humidity, and wind speed were negatively correlated with surface SO2 concentration, while pressure was positively correlated. Furthermore, it was found that dew point was a more effective predictor than temperature. When these meteorological factors were used in multiple regression, the determination coefficient reached 0.379. The relationship of the surface SO2 concentration and meteorological factors was seasonally dependent. In summer and autumn, the regression model performed better than in spring and winter. The surface SO2 concentration predicting method proposed in this study can be easily adapted for other regions, especially most useful for those having no operational air pollution forecasting services or having sparse ground monitoring networks.
Selective oxidation of dual phase steel after annealing at different dew points
NASA Astrophysics Data System (ADS)
Lins, Vanessa de Freitas Cunha; Madeira, Laureanny; Vilela, Jose Mario Carneiro; Andrade, Margareth Spangler; Buono, Vicente Tadeu Lopes; Guimarães, Juliana Porto; Alvarenga, Evandro de Azevedo
2011-04-01
Hot galvanized steels have been extensively used in the automotive industry. Selective oxidation on the steel surface affects the wettability of zinc on steel and the grain orientation of inhibition layer (Fe-Al-Zn alloy) and reduces the iron diffusion to the zinc layer. The aim of this work is to identify and quantify selective oxidation on the surface of a dual phase steel, and an experimental steel with a lower content of manganese, annealed at different dew points. The techniques employed were atomic force microscopy, X-ray photoelectron spectroscopy, and glow discharge optical emission spectroscopy. External selective oxidation was observed for phosphorus on steel surface annealed at 0 °C dp, and for manganese, silicon, and aluminum at a lower dew point. The concentration of manganese was higher on the dual phase steel surface than on the surface of the experimental steel. The concentration of molybdenum on the surface of both steels increased as the depth increased.
NASA Astrophysics Data System (ADS)
Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel
2012-09-01
The first European humidity key comparison EURAMET-T.K6 was completed in 2008, and it covered the dew-point temperature range from -50 °C to + 20 °C. Both LPM and MIKES participated in the comparison, but a new low dew-point generator was introduced at LPM as a result of progress in the EUROMET P912 project. To extend the range of available comparison evidence down to -70 °C and to study the validity of improved uncertainties of LPM, a bilateral comparison was carried out between LPM and MIKES in 2009-2010. The applied comparison procedure was similar to that applied in EURAMET-T.K6. However, only one transfer standard was used instead of two units and the measurement point -70 °C was added in the measurement scheme. The results show that the bilateral equivalence between LPM and MIKES is between (0.00 ± 0.06) °C and (0.02 ± 0.08) °C in the range from -50 °C to + 20 °C and (0.01 ± 0.10) °C at -70 °C. Using MIKES results as the link to the EURAMET.T-K6, it is shown that the difference between the results obtained with the new LPM dew-point temperature standard and the EURAMET Comparison Reference Values is between (-0.02 ± 0.08) °C at 20 °C and (+ 0.02 ± 0.07) ° C at -50 °C.
Tao, Ye; Zhang, Yuan Ming
2012-05-01
Leaf hair points (LHPs) are important morphological structures in many desiccation-tolerant mosses, but study of their functions has been limited. A desert moss, Syntrichia caninervis, was chosen for examination of the ecological effects of LHPs on water retention and dew formation at individual and population (patch) levels. Although LHPs were only 4.77% of shoot weight, they were able to increase absolute water content (AWC) by 24.87%. The AWC of samples with LHPs was always greater than for those without LHPs during dehydration. The accumulative evaporation ratio (AER) showed an opposite trend. AWC, evaporation ratio and AER of shoots with LHPs took 20 min longer to reach a completely dehydrated state than shoots without LHPs. At the population level, dew formation on moss crusts with LHPs was faster than on crusts without LHPs, and the former had higher daily and total dew amounts. LHPs were able to improve dew amounts on crusts by 10.26%. Following three simulated rainfall events (1, 3 and 6 mm), AERs from crusts with LHPs were always lower than from crusts without LHPs. LHPs can therefore significantly delay and reduce evaporation. We confirm that LHPs are important desiccation-tolerant features of S. caninervis at both individual and population levels. LHPs greatly aid moss crusts in adapting to arid conditions.
A conceptual weather-type classification procedure for the Philadelphia, Pennsylvania, area
McCabe, Gregory J.
1990-01-01
A simple method of weather-type classification, based on a conceptual model of pressure systems that pass through the Philadelphia, Pennsylvania, area, has been developed. The only inputs required for the procedure are daily mean wind direction and cloud cover, which are used to index the relative position of pressure systems and fronts to Philadelphia.Daily mean wind-direction and cloud-cover data recorded at Philadelphia, Pennsylvania, from January 1954 through August 1988 were used to categorize daily weather conditions. The conceptual weather types reflect changes in daily air and dew-point temperatures, and changes in monthly mean temperature and monthly and annual precipitation. The weather-type classification produced by using the conceptual model was similar to a classification produced by using a multivariate statistical classification procedure. Even though the conceptual weather types are derived from a small amount of data, they appear to account for the variability of daily weather patterns sufficiently to describe distinct weather conditions for use in environmental analyses of weather-sensitive processes.
Flores, María Elena Báez; Medina, Pável Gaxiola; Camacho, Sylvia Páz Díaz; de Jesús Uribe Beltrán, Magdalena; De la Cruz Otero, María del Carmen; Ramírez, Ignacio Osuna; Hernández, Martín Ernesto Tiznado
2014-08-01
The fungal spore concentration (FSC) in the air poses a risk for human health. This work studied the FSC in university libraries and how it is affected by environmental factors. A total of 347 samples were obtained using a Microbio MB2(®) Aerosol Sampler. The wind speed (WS), cross wind (CW), temperature (T), relative humidity (HR), barometric pressure (BP) and dew point (DP) were recorded using a Kestrel(®) 4500 weather station. The median indoor/outdoor FSC was 360/1230 CFU m(-3). FSC correlated inversely with BP, HR and DP; and positively with WS and CW; whereas T showed negative or positive correlation with FSC, depending on the region or sampling time. Eleven fungal genera were found and the dominant isolates were identified as Aspergillus niger, Aspergillus tamarii and Aspergillus oryzae. All fungi identified are known to be allergenic. It was concluded that environmental variables can influence the air FSC in different ways.
Analysis of the surface heat balance over the world ocean
NASA Technical Reports Server (NTRS)
Esbenson, S. K.
1981-01-01
The net surface heat fluxes over the global ocean for all calendar months were evaluated. To obtain a formula in the form Qs = Q2(T*A - Ts), where Qs is the net surface heat flux, Ts is the sea surface temperature, T*A is the apparent atmospheric equilibrium temperature, and Q2 is the proportionality constant. Here T*A and Q2, derived from the original heat flux formulas, are functions of the surface meteorological parameters (e.g., surface wind speed, air temperature, dew point, etc.) and the surface radiation parameters. This formulation of the net surface heat flux together with climatological atmospheric parameters provides a realistic and computationally efficient upper boundary condition for oceanic climate modeling.
Meteorological annual report for 1995 at the Savannah River Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hunter, C.H.; Tatum, C.P.
1996-12-01
The Environmental Technology Section (ETS) of the Savannah River Technology Center (SRTC) collects, archives, and analyzes basic meteorological data supporting a variety of activities at SRS. These activities include the design, construction, and operation of nuclear and non-nuclear facilities, emergency response, environmental compliance, resource management, and environmental research. This report contains tabular and graphical summaries of data collected during 1995 for temperature, precipitation, relative humidity, wind, barometric pressure, and solar radiation. Most of these data were collected at the central Climatology Facility. Summaries of temperature and relative humidity were generated with data from the lowest level of measurement at themore » Central Climatology Site tower (13 feet above ground). (Relative humidity is calculated from measurements of dew-point temperature.) Wind speed summaries were generated with data from the second measurement level (58 feet above ground). Wind speed measurements from this level are believed to best represent open, well-exposed areas of the Site. Precipitation summaries were based on data from the Building 773-A site since quality control algorithms for the central Climatology Facility rain gauge data were not finalized at the time this report was prepared. This report also contains seasonal and annual summaries of joint occurrence frequencies for selected wind speed categories by 22.5 degree wind direction sector (i.e., wind roses). Wind rose summaries are provided for the 200-foot level of the Central Climatology tower and for each of the eight 200-foot area towers.« less
NASA Astrophysics Data System (ADS)
Cesar, Maria das Graças M. M.; Mantel, Marc J.
2003-01-01
The oxide subscale formed on the decarburization annealing of 3% Si-Fe was investigated using microscopy and spectroscopy techniques. It was found that the morphology as well as the molecular structure of the subscale are affected by temperature and dew point. The results suggest that there is an optimum level of internal oxidation and an optimum fayalite/silica ratio in the subscale to achieve a oriented grain silicon steel having a continuous and smooth ceramic film and low core loss.
2000-03-01
For Figures 17 and 18, the H20 content of the N2 gas flow is ណ ppm ( dew point < 220 K); for Figure 19, the HC1 content of the gas stream is 30 ppm...the same temperature to prevent supersaturation. We have calibrated the water delivery system in H2S04 trapping experiments, 35 by a dew point ...We have investigated the activities of different types of aluminum oxide particles for uptake of gas -phase H20 and HCI. The particle types
NASA Astrophysics Data System (ADS)
Micheli, L.; Dodge, C.; Fernandez, D.; Weiss, P. L.; Flint, L. E.; Flint, A. L.; Torregrosa, A.
2016-12-01
Summertime coastal fog advects from the ocean and transports water inland in the form of fog droplets to forests and grasslands. The amount of fog water delivered to the soil through fog drip from foliage and other surfaces that have captured and accumulated the droplets is often difficult to quantify due to many challenges including the difficulty of measuring the relatively small variations in soil moisture that accompany fog events. This study details summer season records collected from 4 sites at the Pepperwood Preserve in Santa Rosa, CA. Fog drip volumes were measured using 1 m2 standard fog collectors located at a grassland site for the past three summers. Soil moisture measurements were collected for portions of the three summer seasons from three sites: two oak woodland understory sites and a grassland site on the edge of a forest. One oak woodland site was within 400 m of the standard fog collector grassland site. Leaf wetness sensors (LWS) were co-located at all soil moisture sites. We observe a much higher frequency of wet periods at the grassland site than at the nearby oak woodland site during the summer fog season. One hypothesis is that the oak canopy acts to protect the LWS at the oak woodland site from nocturnal radiative cooling, thereby reducing condensation and dew formation. Another hypothesis is that the oak woodland canopy tends sheltered the understory during light fog events, resulting in edge effects that may tend to reduce fog deposition within the canopy. Leaf and soil moisture measurements both during fog events and during periods without fog but when dew point is reached may provide a more complete picture of non-rain mechanisms of moisture delivery to the foliage and the soil. Investigations are on-going to include corresponding meteorological data (wind speed and direction, relative humidity and temperature) to understand relative contributions to the soil associated with both fog and dew and to better distinguish between fog and dew inputs.
NASA Astrophysics Data System (ADS)
Pourmajidian, Maedeh; McDermid, Joseph R.
2018-03-01
The present study investigates the selective oxidation of a 0.1C-6Mn-2Si medium-Mn advanced high-strength steel during austenization annealing heat treatments as a function of process atmosphere oxygen partial pressure and annealing time. It was determined that the surface oxide growth kinetics followed a parabolic rate law with the minimum rate belonging to the lowest oxygen partial pressure atmosphere at a dew point of 223 K (- 50 °C). The chemistry of the surface and subsurface oxides was studied using STEM + EELS on the sample cross sections, and it was found that the surface oxides formed under the 223 K (- 50 °C) dew-point atmosphere consisted of a layered configuration of SiO2, MnSiO3, and MnO, while in the case of the higher pO2 process atmospheres, only MnO was detected at the surface. Consistent with the Wagner calculations, it was shown that the transition to internal oxidation for Mn occurred under the 243 K (- 30 °C) and 278 K (+ 5 °C) dew-point atmospheres. However, the predictions of the external to internal oxidation for Si using the Wagner model did not correlate well with the experimental findings nor did the predictions of the Mataigne et al. model for multi-element alloys. Investigations of the internal oxide network at the grain boundaries revealed a multilayer oxide structure composed of amorphous SiO2 and crystalline MnSiO3, respectively, at the oxide core and outer shell. A mechanism for the formation of the oxide morphologies observed, based on kinetic and thermodynamic factors, was proposed. It is expected that only the fine and nodule-like MnO oxides formed on the surface of the samples annealed under the 278 K (+ 5 °C) dew-point process atmosphere for 60 and 120 seconds are sufficiently thin and of the desired dispersed morphology to promote reactive wetting by the molten galvanizing bath.
Monthly variations of dew point temperature in the coterminous United States
NASA Astrophysics Data System (ADS)
Robinson, Peter J.
1998-11-01
The dew point temperature, Td, data from the surface airways data set of the U.S. National Climatic Data Center were used to develop a basic dew point climatology for the coterminous United States. Quality control procedures were an integral part of the analysis. Daily Td, derived as the average of eight observations at 3-hourly intervals, for 222 stations for the 1961-1990 period were used. The annual and seasonal pattern of average values showed a clear south-north decrease in the eastern portion of the nation, a trend which was most marked in winter. In the west, values decreased inland from the Pacific Coast. Inter-annual variability was generally low when actual mean values were high. A cluster analysis suggested that the area could be divided into six regions, two oriented north-south in the west, four aligned east-west in the area east of the Rocky Mountains. Day-to-day variability was low in all seasons in the two western clusters, but showed a distinct winter maximum in the east. This was explained in broad terms by consideration of air flow regimes, with the Pacific Ocean and the Gulf of Mexico acting as the major moisture sources. Comparison of values for pairs of nearby stations suggested that Td was rather insensitive to local moisture sources. Analysis of the patterns of occurrence of dew points exceeding the 95th percentile threshold indicated that extremes in summer tend to be localized and short-lived, while in winter they are more widespread and persistent.
NASA Astrophysics Data System (ADS)
Heinonen, Martti; Anagnostou, Miltiadis; Bell, Stephanie; Stevens, Mark; Benyon, Robert; Bergerud, Reidun Anita; Bojkovski, Jovan; Bosma, Rien; Nielsen, Jan; Böse, Norbert; Cromwell, Plunkett; Kartal Dogan, Aliye; Aytekin, Seda; Uytun, Ali; Fernicola, Vito; Flakiewicz, Krzysztof; Blanquart, Bertrand; Hudoklin, Domen; Jacobson, Per; Kentved, Anders; Lóio, Isabel; Mamontov, George; Masarykova, Alexandra; Mitter, Helmut; Mnguni, Regina; Otych, Jan; Steiner, Anton; Szilágyi Zsófia, Nagyné; Zvizdic, Davor
2012-09-01
In the field of humidity quantities, the first CIPM key comparison, CCT-K6 is at its end. The corresponding European regional key comparison, EUROMET.T-K6, was completed in early 2008, about 4 years after the starting initial measurements in the project. In total, 24 NMIs from different countries took part in the comparison. This number includes 22 EURAMET countries, and Russia and South Africa. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was carried out in three parallel loops, each with two chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. It is shown that the standard uncertainty due to the long-term instability was smaller than 0.008 °C in all loops. The standard uncertainties due to links between the loops were found to be smaller than 0.025 °C at -50 °C and 0.010 °C elsewhere. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from the EURAMET comparison reference values (ERV). Taking into account 16 different primary dew-point realizations and 8 secondary realizations, the results demonstrate the equivalence of a large number of laboratories at an uncertainty level that is better than achieved in other multilateral comparisons so far in the humidity field.
Nelsen, C E; Safir, G R; Hanson, A D
1978-01-01
Leaf water potential (Psi(leaf)) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Psi(leaf) values from the dew point hygrometer were too high. Agreement was improved by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Psi(leaf) values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status.
NASA Astrophysics Data System (ADS)
Meyer, C.; Solano, A.
2016-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.
2014-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Huang, Peter; Meyer, Christopher; Brionizio, Julio D.
2015-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Closed Cycle Electric Discharge Laser Design Investigation
1978-03-01
Report Number Assigned by Contract Monitor: NASA CR- 135408 Comments on Document: Archive, RRI, DEW Descriptors, Keywords: Closed Cycle Electric...Discharge Laser Design Investigation Carbon Dioxide Monoxide Space Airborne Heat Disposal Point Track Power Solar Generator Radiation Pages: 00100...Cataloged Date: Nov 27,1992 Contract Number: NAS 3-20100 Document Type: HC Number of Copies In Library: 000001 Record ID: 25219 Source of Document: DEW
Meteorological conditions are associated with physical activities performed in open-air settings
NASA Astrophysics Data System (ADS)
Suminski, Richard R.; Poston, Walker C.; Market, Patrick; Hyder, Melissa; Sara, Pyle A.
2008-01-01
Meteorological conditions (MC) are believed to modify physical activity. However, studies in this area are limited and none have looked at the associations between MC and physical activity in open-air settings. Therefore, we examined the relationships between MC and physical activities performed on sidewalks/streets and outdoor oval tracks. Observation techniques were used to count individuals walking to school, exercising on oval tracks and walking/jogging/biking on sidewalks/streets. Meteorological conditions were obtained from an Automated Surface Observing System located at a nearby airport for the same time periods physical activities were observed. On weekdays, fewer children were seen walking to school and more bicyclists were observed on sidewalks/streets as wind speed increased ( p < 0.05). Ambient and apparent temperatures were positively ( p < 0.05) and humidity and barometric pressure negatively ( p < 0.005) related to the number of individuals walking on the track. Meteorological conditions were not significantly associated with physical activities observed on weekends. Multiple linear regression analyses showed that apparent temperature (+), barometric pressure (-) and dew point (-) accounted for 58.0% of the variance in the number of walkers on the track. A significant proportion of the variance (>30%) in the number of joggers and the length of time they jogged was accounted for by apparent temperature (+) and dew point (-). We found that meteorological conditions are related to physical activity in open-air settings. The results embellish the context in which environmental-physical activity relationships should be interpreted and provide important information for researchers applying the observation method in open-air settings.
Benchmark Data Set for Wheat Growth Models: Field Experiments and AgMIP Multi-Model Simulations.
NASA Technical Reports Server (NTRS)
Asseng, S.; Ewert, F.; Martre, P.; Rosenzweig, C.; Jones, J. W.; Hatfield, J. L.; Ruane, A. C.; Boote, K. J.; Thorburn, P.J.; Rotter, R. P.
2015-01-01
The data set includes a current representative management treatment from detailed, quality-tested sentinel field experiments with wheat from four contrasting environments including Australia, The Netherlands, India and Argentina. Measurements include local daily climate data (solar radiation, maximum and minimum temperature, precipitation, surface wind, dew point temperature, relative humidity, and vapor pressure), soil characteristics, frequent growth, nitrogen in crop and soil, crop and soil water and yield components. Simulations include results from 27 wheat models and a sensitivity analysis with 26 models and 30 years (1981-2010) for each location, for elevated atmospheric CO2 and temperature changes, a heat stress sensitivity analysis at anthesis, and a sensitivity analysis with soil and crop management variations and a Global Climate Model end-century scenario.
Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments
NASA Astrophysics Data System (ADS)
Zvizdic, D.; Heinonen, M.; Sestan, D.
2015-08-01
The aim of this paper is to describe the evaluation process of the performance of the low-range saturator (LRS), when exposed to two different thermal environments. The examined saturator was designed, built, and tested at MIKES (Centre for Metrology and Accreditation, Finland), and then transported to the Laboratory for Process Measurement (LPM) in Croatia, where it was implemented in a new dew-point calibration system. The saturator works on a single-pressure-single-pass generation principle in the dew/frost-point temperature range between and . The purpose of the various tests performed at MIKES was to examine the efficiency and non-ideality of the saturator. As a test bath facility in Croatia differs from the one used in Finland, the same tests were repeated at LPM, and the effects of different thermal conditions on saturator performance were examined. Thermometers, pressure gauges, an air preparation system, and water for filling the saturator at LPM were also different than those used at MIKES. Results obtained by both laboratories indicate that the efficiency of the examined saturator was not affected either by the thermal conditions under which it was tested or by equipment used for the tests. Both laboratories concluded that LRS is efficient enough for a primary realization of the dew/frost-point temperature scale in the range from to , with flow rates between and . It is also shown that a considerable difference of the pre-saturator efficiency, indicated by two laboratories, did not have influence to the overall performance of the saturator. The results of the research are presented in graphical and tabular forms. This paper also gives a brief description of the design and operation principle of the investigated low-range saturator.
Using a Statistical Approach to Anticipate Leaf Wetness Duration Under Climate Change in France
NASA Astrophysics Data System (ADS)
Huard, F.; Imig, A. F.; Perrin, P.
2014-12-01
Leaf wetness plays a major role in the development of fungal plant diseases. Leaf wetness duration (LWD) above a threshold value is determinant for infection and can be seen as a good indicator of impact of climate on infection occurrence and risk. As LWD is not widely measured, several methods, based on physics and empirical approach, have been developed to estimate it from weather data. Many LWD statistical models do exist, but the lack of standard for measurements require reassessments. A new empirical LWD model, called MEDHI (Modèle d'Estimation de la Durée d'Humectation à l'Inra) was developed for french configuration for wetness sensors (angle : 90°, height : 50 cm). This deployment is different from what is usually recommended from constructors or authors in other countries (angle from 10 to 60°, height from 10 to 150 cm…). MEDHI is a decision support system based on hourly climatic conditions at time steps n and n-1 taking account relative humidity, rainfall and previously simulated LWD. Air temperature, relative humidity, wind speed, rain and LWD data from several sensors with 2 configurations were measured during 6 months in Toulouse and Avignon (South West and South East of France) to calibrate MEDHI. A comparison of empirical models : NHRH (RH threshold), DPD (dew point depression), CART (classification and regression tree analysis dependant on RH, wind speed and dew point depression) and MEDHI, using meteorological and LWD measurements obtained during 5 months in Toulouse, showed that the development of this new model MEHDI was definitely better adapted to French conditions. In the context of climate change, MEDHI was used for mapping the evolution of leaf wetness duration in France from 1950 to 2100 with the French regional climate model ALADIN under different Representative Concentration Pathways (RCPs) and using a QM (Quantile-Mapping) statistical downscaling method. Results give information on the spatial distribution of infection risks during the current century. Such approach could be easily combined with thermal response curves of fungal infection for various pathogens.
NASA Technical Reports Server (NTRS)
Bauman, William H., III
2010-01-01
The 45th Weather Squadron (45 WS) Launch Weather Officers use the 12-km resolution North American Mesoscale (NAM) model (MesoNAM) text and graphical product forecasts extensively to support launch weather operations. However, the actual performance of the model at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) has not been measured objectively. In order to have tangible evidence of model performance, the 45 WS tasked the Applied Meteorology Unit to conduct a detailed statistical analysis of model output compared to observed values. The model products are provided to the 45 WS by ACTA, Inc. and include hourly forecasts from 0 to 84 hours based on model initialization times of 00, 06, 12 and 18 UTC. The objective analysis compared the MesoNAM forecast winds, temperature and dew point, as well as the changes in these parameters over time, to the observed values from the sensors in the KSC/CCAFS wind tower network. Objective statistics will give the forecasters knowledge of the model's strength and weaknesses, which will result in improved forecasts for operations.
NASA Technical Reports Server (NTRS)
Watson, Leela R.
2011-01-01
The 45th Weather Squadron Launch Weather Officers use the 12-km resolution North American Mesoscale model (MesoNAM) forecasts to support launch weather operations. In Phase I, the performance of the model at KSC/CCAFS was measured objectively by conducting a detailed statistical analysis of model output compared to observed values. The objective analysis compared the MesoNAM forecast winds, temperature, and dew point to the observed values from the sensors in the KSC/CCAFS wind tower network. In Phase II, the AMU modified the current tool by adding an additional 15 months of model output to the database and recalculating the verification statistics. The bias, standard deviation of bias, Root Mean Square Error, and Hypothesis test for bias were calculated to verify the performance of the model. The results indicated that the accuracy decreased as the forecast progressed, there was a diurnal signal in temperature with a cool bias during the late night and a warm bias during the afternoon, and there was a diurnal signal in dewpoint temperature with a low bias during the afternoon and a high bias during the late night.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelsen, C.E.; Safir, G.R.; Hanson, A.D.
1978-01-01
Leaf water potential (Psi/sub leaf/) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Psi/sub leaf/ values from the dew point hygrometer were too high. Agreement was improvedmore » by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Psi/sub leaf/ values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status.« less
NASA Astrophysics Data System (ADS)
Meyer, C. W.; Hill, K. D.
2015-01-01
A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Development of the High-Temperature Dew-Point Generator Over the Past 15 Years
NASA Astrophysics Data System (ADS)
Bosma, R.; Nielsen, J.; Peruzzi, A.
2017-10-01
At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from 70 {°}C to 95 {°}C dew-point temperature, and the last modification allows an uncertainty of 0.048 {°}C (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to 95 {°}C. In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within 0.01 {°}C with PTB and NPL.
Developing and Validating a Santa Ana Wildfire Threat Index
NASA Astrophysics Data System (ADS)
Capps, S. B.; Rolinski, T.; DAgostino, B.; Vanderburg, S.; Fovell, R. G.; Cao, Y.
2014-12-01
Santa Ana winds, common to southern California during the fall through spring, are a type of katabatic wind that originates from a direction generally ranging from 360°/0° to 100° and is usually accompanied by very low humidity. Since fuel conditions tend to be driest from late September through the middle of November, Santa Ana winds occurring during this period have the greatest potential to produce large, devastating fires when an ignition occurs. Such catastrophic fires occurred in 1993, 2003, 2007, and 2008. Because of the destructive nature of these fires, there has been a growing desire to categorize Santa Ana wind events in much the same way that tropical cyclones have been categorized. The Santa Ana Wildfire Threat index (SAWT) is an attempt to categorize such events with respect to fire activity, based on surface wind velocity, dew point depression, and forecasted fuel conditions. The index, a USDA Forest Service product, was developed by the Forest Service in collaboration with San Diego Gas and Electric Utility (SDG&E), the Department of Atmospheric and Oceanic Sciences at UCLA, The Desert Research Institute (DRI), and Vertum Partners. The methodology behind the SAWT index, along with the index itself will be presented in detail. Also, there will be a discussion on the construction of a 30-year climatology of the index, which includes various meteorological and fuel parameters. We will demonstrate the usefulness of the index as another decision support tool for fire agencies and first responders, and how it could assist the general public and private industry in the preparation of critical Santa Ana wind events.
Aircraft measurements and analysis of severe storms: 1975 field experiment
NASA Technical Reports Server (NTRS)
Sinclair, P. C.
1976-01-01
Three aircraft and instrumentation systems were acquired in support of the severe storm surveillance program. The data results indicate that the original concept of a highly mobile research aircraft capability for obtaining detailed measurements of wind, temperature, dew point, etc., near and within specifically designated severe storms is entirely feasible and has been demonstrated for the first time by this program. This program is unique in that it is designed to be highly mobile in order to move to and/or with the developing storm systems to obtain the necessary measurements. Previous programs have all been fixed to a particular location and therefore have had to wait for the storms to come within their network. The present research is designed around a highly mobile aircraft measurements group in order to maximize the storm cases during the field measurements program.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1978-10-03
This report is a six-part statistical summary of surface weather observations for Torrejon AB, Madrid Spain. It contains the following parts: (A) Weather Conditions; Atmospheric Phenomena; (B) Precipitation, Snowfall and Snow Depth (daily amounts and extreme values); (C) Surface winds; (D) Ceiling Versus Visibility; Sky Cover; (E) Psychrometric Summaries (daily maximum and minimum temperatures, extreme maximum and minimum temperatures, psychrometric summary of wet-bulb temperature depression versus dry-bulb temperature, means and standard deviations of dry-bulb, wet-bulb and dew-point temperatures and relative humidity); and (F) Pressure Summary (means, standard, deviations, and observation counts of station pressure and sea-level pressure). Data in thismore » report are presented in tabular form, in most cases in percentage frequency of occurrence or cumulative percentage frequency of occurrence tables.« less
ERIC Educational Resources Information Center
Pinkham, Chester A.; Barrett, Kristin Burrows
1992-01-01
Describes four experiments that enable students to explore the phenomena of evaporation and condensation and determine the relative humidity by measuring air temperature and dew point on warm September days. Provides tables to calculate saturation points and relative humidity. (MDH)
Leaf wetness distribution within a potato crop
NASA Astrophysics Data System (ADS)
Heusinkveld, B. G.
2010-07-01
The Netherlands has a mild maritime climate and therefore the major interest in leaf wetness is associated with foliar plant diseases. During moist micrometeorological conditions (i.e. dew, fog, rain), foliar fungal diseases may develop quickly and thereby destroy a crop quickly. Potato crop monocultures covering several hectares are especially vulnerable to such diseases. Therefore understanding and predicting leaf wetness in potato crops is crucial in crop disease control strategies. A field experiment was carried out in a large homogeneous potato crop in the Netherlands during the growing season of 2008. Two innovative sensor networks were installed as a 3 by 3 grid at 3 heights covering an area of about 2 hectares within two larger potato crops. One crop was located on a sandy soil and one crop on a sandy peat soil. In most cases leaf wetting starts in the top layer and then progresses downward. Leaf drying takes place in the same order after sunrise. A canopy dew simulation model was applied to simulate spatial leaf wetness distribution. The dew model is based on an energy balance model. The model can be run using information on the above-canopy wind speed, air temperature, humidity, net radiation and within canopy air temperature, humidity and soil moisture content and temperature conditions. Rainfall was accounted for by applying an interception model. The results of the dew model agreed well with the leaf wetness sensors if all local conditions were considered. The measurements show that the spatial correlation of leaf wetness decreases downward.
NASA Astrophysics Data System (ADS)
Mishra, Dhirendra; Goyal, P.; Upadhyay, Abhishek
2015-02-01
Delhi has been listed as the worst performer across the world with respect to the presence of alarmingly high level of haze episodes, exposing the residents here to a host of diseases including respiratory disease, chronic obstructive pulmonary disorder and lung cancer. This study aimed to analyze the haze episodes in a year and to develop the forecasting methodologies for it. The air pollutants, e.g., CO, O3, NO2, SO2, PM2.5 as well as meteorological parameters (pressure, temperature, wind speed, wind direction index, relative humidity, visibility, dew point temperature, etc.) have been used in the present study to analyze the haze episodes in Delhi urban area. The nature of these episodes, their possible causes, and their major features are discussed in terms of fine particulate matter (PM2.5) and relative humidity. The correlation matrix shows that temperature, pressure, wind speed, O3, and dew point temperature are the dominating variables for PM2.5 concentrations in Delhi. The hour-by-hour analysis of past data pattern at different monitoring stations suggest that the haze hours were occurred approximately 48% of the total observed hours in the year, 2012 over Delhi urban area. The haze hour forecasting models in terms of PM2.5 concentrations (more than 50 μg/m3) and relative humidity (less than 90%) have been developed through artificial intelligence based Neuro-Fuzzy (NF) techniques and compared with the other modeling techniques e.g., multiple linear regression (MLR), and artificial neural network (ANN). The haze hour's data for nine months, i.e. from January to September have been chosen for training and remaining three months, i.e., October to December in the year 2012 are chosen for validation of the developed models. The forecasted results are compared with the observed values with different statistical measures, e.g., correlation coefficients (R), normalized mean square error (NMSE), fractional bias (FB) and index of agreement (IOA). The performed analysis has indicated that R has values 0.25 for MLR, 0.53 for ANN, and NF: 0.72, between the observed and predicted PM2.5 concentrations during haze hours invalidation period. The results show that the artificial intelligence implementations have a more reasonable agreement with the observed values. Finally, it can be concluded that the most convincing advantage of artificial intelligence based NF model is capable for better forecasting of haze episodes in Delhi urban area than ANN and MLR models.
Ershow, Gennady Moiseevich; Kirillov, Evgenii Vladislavovich; Mirzabekov, Andrei Darievich
1998-01-01
A device for dispensing microdoses of aqueous solutions are provided, whereby the substance is transferred by the free surface end of a rodlike transferring element; the temperature of the transferring element is maintained at essentially the dew point of the ambient air during the transfer. The device may comprise a plate-like base to which are affixed a plurality of rods; the unfixed butt ends of the rods are coplanar. The device further comprises a means for maintaining the temperature of the unfixed butt ends of the rods essentially equal to the dew point of the ambient air during transfer of the aqueous substance.
Analysis and Design of a High Power Laser Adaptive Phased Array Transmitter
1977-12-01
Report Number Assigned by Contract Monitor: SLL 80-711; CR75-537/501 Comments on Document: Archive, RRI, DEW Descriptors, Keywords: Analysis Design...Document: DEW j ^ yrf^N H tpm *■ ww CRT»5g:’’""J{ it.. 2. Government Accession No. 3. Recipient’s Catalog No. 4. Title and Subtitle Analysis...Target Plane (e = 0, Range = 185000 M, Five 0.96 M Subapertures, Pointing Plus Phase Adaption for 10.6 pm Propagation in Vacuum) ... 80 :il-14
Atmospheric Science Data Center
2015-11-25
... Dew/Frost Point Temperature Diffusional Growth Rate Ice Water Concent Particle Diameter Particle Number Concentration Precipitation Rate Radar Reflectivity Relative Humidity Static Pressure Vertical ...
Atmospheric Science Data Center
2015-11-25
... Dew/Frost Point Temperature Diffusional Growth Rate Ice Water Content Particle Diameter Particle Number Concentration Precipitation Rate Radar Reflectivity Relative Humidity Static Pressure Vertical ...
Atmospheric Science Data Center
2015-11-25
... Dew/Frost Point Temperature Diffusional Growth Rate Ice Water Content Particle Diameter Particle Number Concentration Preciptiation Rate Radar Reflectivity Relative Humidity Static Pressure Vertical ...
NASA Astrophysics Data System (ADS)
Paczesny, Daniel; Mikłaszewicz, Franciszek
2013-10-01
This article describes the design, construction and parameters of diagnostic medical system for air humidity measurement which can be proceeded in various places of human nasal cavities and also human throat. The system can measure dynamic changes of dew point temperature (absolute value of humidity) of inspired and expired air in different places of human upper airways. During regular respiration process dew point temperature is measured in nasal cavity, middle part cavity and nasopharynx. The presented system is the next step in construction of measurement system based on specialized microsystem for laryngological application. The microsystem fabricated on silicon substrate includes microheater, microthermoresistor and interdigitated electrodes. In comparison with previously built measurement system with current version some system functionalities and measurement parameters were improved. Additionally 3D printing technology was applied for rapid prototyping a measurement system housing. Presented measurement system is set of microprocessor module with signal conditioning circuits; heated measurement head based on specialized microsystem with disposable heated pipe for air sucking from various places of upper airways; power supplier and computer application for monitoring all system parameters and presenting on-line and off-line measured results. Some example results of constructed measurement system and dew point temperature measurements during respiration cycle are presented.
NASA Astrophysics Data System (ADS)
Zhang, Ziran; Glaser, Steven D.; Bales, Roger C.; Conklin, Martha; Rice, Robert; Marks, Danny G.
2017-05-01
A network of sensors for spatially representative water-balance measurements was developed and deployed across the 2000 km2 snow-dominated portion of the upper American River basin, primarily to measure changes in snowpack and soil-water storage, air temperature, and humidity. This wireless sensor network (WSN) consists of 14 sensor clusters, each with 10 measurement nodes that were strategically placed within a 1 km2 area, across different elevations, aspects, slopes, and canopy covers. Compared to existing operational sensor installations, the WSN reduces hydrologic uncertainty in at least three ways. First, redundant measurements improved estimation of lapse rates for air and dew-point temperature. Second, distributed measurements captured local variability and constrained uncertainty in air and dew-point temperature, snow accumulation, and derived hydrologic attributes important for modeling and prediction. Third, the distributed relative-humidity measurements offer a unique capability to monitor upper-basin patterns in dew-point temperature and characterize elevation gradient of water vapor-pressure deficit across steep, variable topography. Network statistics during the first year of operation demonstrated that the WSN was robust for cold, wet, and windy conditions in the basin. The electronic technology used in the WSN-reduced adverse effects, such as high current consumption, multipath signal fading, and clock drift, seen in previous remote WSNs.
Atmospheric Science Data Center
2015-11-25
... Microwave Radiometer Optical Counter Platinum Resistance Pyranometer Pyrgeometer Variable Capacitance ... Parameters: Aerosol Particle Properties Air Temperature Cloud Liquid Water Deiced Temperature Dew Point Doppler ...
Mapping Atmospheric Moisture Climatologies across the Conterminous United States
Daly, Christopher; Smith, Joseph I.; Olson, Keith V.
2015-01-01
Spatial climate datasets of 1981–2010 long-term mean monthly average dew point and minimum and maximum vapor pressure deficit were developed for the conterminous United States at 30-arcsec (~800m) resolution. Interpolation of long-term averages (twelve monthly values per variable) was performed using PRISM (Parameter-elevation Relationships on Independent Slopes Model). Surface stations available for analysis numbered only 4,000 for dew point and 3,500 for vapor pressure deficit, compared to 16,000 for previously-developed grids of 1981–2010 long-term mean monthly minimum and maximum temperature. Therefore, a form of Climatologically-Aided Interpolation (CAI) was used, in which the 1981–2010 temperature grids were used as predictor grids. For each grid cell, PRISM calculated a local regression function between the interpolated climate variable and the predictor grid. Nearby stations entering the regression were assigned weights based on the physiographic similarity of the station to the grid cell that included the effects of distance, elevation, coastal proximity, vertical atmospheric layer, and topographic position. Interpolation uncertainties were estimated using cross-validation exercises. Given that CAI interpolation was used, a new method was developed to allow uncertainties in predictor grids to be accounted for in estimating the total interpolation error. Local land use/land cover properties had noticeable effects on the spatial patterns of atmospheric moisture content and deficit. An example of this was relatively high dew points and low vapor pressure deficits at stations located in or near irrigated fields. The new grids, in combination with existing temperature grids, enable the user to derive a full suite of atmospheric moisture variables, such as minimum and maximum relative humidity, vapor pressure, and dew point depression, with accompanying assumptions. All of these grids are available online at http://prism.oregonstate.edu, and include 800-m and 4-km resolution data, images, metadata, pedigree information, and station inventory files. PMID:26485026
Atmospheric Science Data Center
2017-04-26
... of Washington CV-580 Instrument: Platinum resistance Chilled mirror Particle Measuring Systems Electron ... Search Parameters: Pressure Temperature Dew point Humidity Turbulence Liquid water content ...
NASA Astrophysics Data System (ADS)
Szilagyi, Jozsef
2015-11-01
Thirty year normal (1981-2010) monthly latent heat fluxes (ET) over the conterminous United States were estimated by a modified Advection-Aridity model from North American Regional Reanalysis (NARR) radiation and wind as well as Parameter-Elevation Regressions on Independent Slopes Model (PRISM) air and dew-point temperature data. Mean annual ET values were calibrated with PRISM precipitation (P) and validated against United States Geological Survey runoff (Q) data. At the six-digit Hydrologic Unit Code level (sample size of 334) the estimated 30 year normal runoff (P - ET) had a bias of 18 mm yr-1, a root-mean-square error of 96 mm yr-1, and a linear correlation coefficient value of 0.95, making the estimates on par with the latest Land Surface Model results but without the need for soil and vegetation information or any soil moisture budgeting.
NASA Technical Reports Server (NTRS)
Snow, W. L.; Morris, O. A.
1984-01-01
Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow.
Developing a predictive tropospheric ozone model for Tabriz
NASA Astrophysics Data System (ADS)
Khatibi, Rahman; Naghipour, Leila; Ghorbani, Mohammad A.; Smith, Michael S.; Karimi, Vahid; Farhoudi, Reza; Delafrouz, Hadi; Arvanaghi, Hadi
2013-04-01
Predictive ozone models are becoming indispensable tools by providing a capability for pollution alerts to serve people who are vulnerable to the risks. We have developed a tropospheric ozone prediction capability for Tabriz, Iran, by using the following five modeling strategies: three regression-type methods: Multiple Linear Regression (MLR), Artificial Neural Networks (ANNs), and Gene Expression Programming (GEP); and two auto-regression-type models: Nonlinear Local Prediction (NLP) to implement chaos theory and Auto-Regressive Integrated Moving Average (ARIMA) models. The regression-type modeling strategies explain the data in terms of: temperature, solar radiation, dew point temperature, and wind speed, by regressing present ozone values to their past values. The ozone time series are available at various time intervals, including hourly intervals, from August 2010 to March 2011. The results for MLR, ANN and GEP models are not overly good but those produced by NLP and ARIMA are promising for the establishing a forecasting capability.
Coyote unmanned aircraft system observations in Hurricane Edouard (2014)
NASA Astrophysics Data System (ADS)
Cione, J. J.; Kalina, E. A.; Uhlhorn, E. W.; Farber, A. M.; Damiano, B.
2016-09-01
Horizontal wind, temperature, and moisture observations are presented from two Coyote unmanned aircraft system (UAS) flights in the boundary layer of Hurricane Edouard (2014). The first flight sampled the meteorological conditions in the eye and eyewall at altitudes from 900 to 1500 m while Edouard was a major hurricane (105 kt) on 16 September 2014. The following day, a second Coyote sampled the inflow layer outside of the storm core at 760 m altitude, when Edouard had weakened to an 80-kt hurricane. These flights represent the first deployments of a UAS from an airborne manned aircraft into a tropical cyclone. Comparisons between the Coyote data and the Lockheed WP-3D Orion (WP-3D) flight-level measurements and analyses constructed from dropsonde data are also provided. On 16 September 2014, the Coyote-measured horizontal wind speeds agree, on average, to within 1 m s-1 of the wind speeds observed by the WP-3D and reproduce the shape of the radial wind profile from the WP-3D measurements. For the inflow layer experiment on 17 September, the mean wind speeds from the Coyote and the dropsonde analysis differ by only 0.5 m s-1, while the Coyote captured increased variability (σ = 3.4 m s-1) in the horizontal wind field compared to the dropsonde analysis (σ = 2.2 m s-1). Thermodynamic data from the Coyote and dropsondes agree well for both flights, with average discrepancies of 0.4°C and 0.0°C for temperature and 0.7°C and 1.3°C for dew point temperature on 16 and 17 September, respectively
Ershov, Gennady Moiseevich; Kirillov, Eugenii Vladislavovich; Mirzabekov, Andrei Darievich
1999-10-05
A method and a device for dispensing microdoses of aqueous solutions are provided, whereby the substance is transferred by the free surface end of a rodlike transferring element; the temperature of the transferring element is maintained at essentially the dew point of the ambient air during the transfer. The device may comprise a plate-like base to which are affixed a plurality of rods; the unfixed butt ends of the rods are coplanar. The device further comprises a means for maintaining the temperature of the unfixed butt ends of the rods essentially equal to the dew point of the ambient air during transfer of the aqueous substance
NASA Astrophysics Data System (ADS)
Hansford, Graeme M.; Freshwater, Ray A.; Eden, Louise; Turnbull, Katharine F. V.; Hadaway, David E.; Ostanin, Victor P.; Jones, Roderic L.
2006-01-01
The design of a very lightweight dew-/frost-point hygrometer for balloon-borne atmospheric water vapor profiling is described. The instrument is based on a surface-acoustic-wave sensor. The low instrument weight is a key feature, allowing flights on meteorological balloons which brings many more flight opportunities. The hygrometer shows consistently good performance in the troposphere and while water vapor measurements near the tropopause and in the stratosphere are possible with the current instrument, the long-time response in these regions hampers realistic measurements. The excellent intrinsic sensitivity of the surface-acoustic-wave sensor should permit considerable improvement in the hygrometer performance in the very dry regions of the atmosphere.
A dew point signaller for conservation of works of art.
Camuffo, D; Valcher, S
1986-03-01
All works of art, from paintings, frescoes, sculptures, to monuments and buildings, are affected by diurnal and seasonal variations of the local microclimate, which induce interactions with the environmental atmosphere. Heat and vapour exchanges cause fluxes of heat and mass between the surface and the atmosphere, and may favour the agressivity of environmental pollutants. Condensation-evaporation cycles are recognized as being very important processes which adversely affect the life-time of the work of art. The need to control the microclimate or to stop condensation processes has been resolved by means of a dew-point signaller especially designed to overcome this problem. This paper discusses the characteristics of this device as well as the environmental philosophy which should be followed when conserving works of art.
NASA Technical Reports Server (NTRS)
Bauman, William H., III
2010-01-01
The 45th Weather Squadron (45 WS) Launch Weather Officers (LWO's) use the 12-km resolution North American Mesoscale (NAM) model (MesoNAM) text and graphical product forecasts extensively to support launch weather operations. However, the actual performance of the model at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) has not been measured objectively. In order to have tangible evidence of model performance, the 45 WS tasked the Applied Meteorology Unit (AMU; Bauman et ai, 2004) to conduct a detailed statistical analysis of model output compared to observed values. The model products are provided to the 45 WS by ACTA, Inc. and include hourly forecasts from 0 to 84 hours based on model initialization times of 00, 06, 12 and 18 UTC. The objective analysis compared the MesoNAM forecast winds, temperature (T) and dew pOint (T d), as well as the changes in these parameters over time, to the observed values from the sensors in the KSC/CCAFS wind tower network shown in Table 1. These objective statistics give the forecasters knowledge of the model's strengths and weaknesses, which will result in improved forecasts for operations.
Atmospheric Science Data Center
2015-11-25
... Hot-Wire Hygrometer RMS Pressure Var Platinum Resistance Pyranometer Radiometer Reverse Flow Spatial ... Parameters: Condensation Nuclei Dew/Frost Point Temperature Droplet Concentration Humidity Irradiance Liquid Water ...
Functional improvements in dried egg white through the Maillard reaction.
Handa, A; Kuroda, N
1999-05-01
The effects of the Maillard reaction on the functional properties of dried egg white (DEW) were investigated. Maillard-reacted DEW (M-DEW) was prepared by storing sugar-preserved DEW (SP-DEW) at 55 degrees C and 35% relative humidity for 0-12 days. The M-DEW developed an excellent gelling property, and hydrogen sulfide production from heat-induced M-DEW gels decreased. Surface sulfhydryl (SH) group content of M-DEW increased while total SH group and alpha-helix contents decreased with increasing heating time in the dry state. Breaking strength, breaking strain, water-holding capacity, and hydrogen sulfide of heat-induced M-DEW gels significantly correlated with surface and total SH group contents in M-DEW. SDS-PAGE revealed that M-DEW proteins were polymerized in which covalent bonds were involved. The present study demonstrated that the Maillard reaction partially unfolds and polymerizes proteins of SP-DEW and, consequently, improved gelling property of SP-DEW under certain controlled conditions.
Atmospheric Science Data Center
2015-11-25
... Flow Angle Sensors Hot-Wire Icing Rate Detector Pressure Transducer Reverse Flow Temperature Probes Spatial ... Condensation Nuclei Dew/Frost Point Temperature Liquid Water Content Nitrogen Dioxide Ozone Pressure Supercooled ...
EDITORIAL: Humidity sensors Humidity sensors
NASA Astrophysics Data System (ADS)
Regtien, Paul P. L.
2012-01-01
All matter is more or less hygroscopic. The moisture content varies with vapour concentration of the surrounding air and, as a consequence, most material properties change with humidity. Mechanical and thermal properties of many materials, such as the tensile strength of adhesives, stiffness of plastics, stoutness of building and packaging materials or the thermal resistivity of isolation materials, all decrease with increasing environmental humidity or cyclic humidity changes. The presence of water vapour may have a detrimental influence on many electrical constructions and systems exposed to humid air, from high-power systems to microcircuits. Water vapour penetrates through coatings, cable insulations and integrated-circuit packages, exerting a fatal influence on the performance of the enclosed systems. For these and many other applications, knowledge of the relationship between moisture content or humidity and material properties or system behaviour is indispensable. This requires hygrometers for process control or test and calibration chambers with high accuracy in the appropriate temperature and humidity range. Humidity measurement methods can roughly be categorized into four groups: water vapour removal (the mass before and after removal is measured); saturation (the air is brought to saturation and the `effort' to reach that state is measured); humidity-dependent parameters (measurement of properties of humid air with a known relation between a specific property and the vapour content, for instance the refractive index, electromagnetic spectrum and acoustic velocity); and absorption (based on the known relation between characteristic properties of non-hydrophobic materials and the amount of absorbed water from the gas to which these materials are exposed). The many basic principles to measure air humidity are described in, for instance, the extensive compilations by Wexler [1] and Sonntag [2]. Absorption-type hygrometers have small dimensions and can be produced at relatively low cost. Therefore, they find wide use in lots of applications. However, the method requires a material that possesses some conflicting properties: stable and reproducible relations between air humidity, moisture uptake and a specific property (for instance the length of a hair, the electrical impedance of the material), fast absorption and desorption of the water vapour (to obtain a short response time), small hysteresis, wide range of relative humidity (RH) and temperature-independent output (only responsive to RH). For these reasons, much research is done and is still going on to find suitable materials that combine high performance and low price. In this special feature, three of the four papers report on absorption sensors, all with different focus. Aziz et al describe experiments with newly developed materials. The surface structure is extensively studied, in view of its ability to rapidly absorb water vapour and exhibit a reproducible change in the resistance and capacitance of the device. Sanchez et al employ optical fibres coated with a thin moisture-absorbing layer as a sensitive humidity sensor. They have studied various coating materials and investigated the possibility of using changes in optical properties of the fibre (here the lossy mode resonance) due to a change in humidity of the surrounding air. The third paper, by Weremczuk et al, focuses on a cheap fabrication method for absorption-based humidity sensors. The inkjet technology appears to be suitable for mass fabrication of such sensors, which is demonstrated by extensive measurements of the electrical properties (resistance and capacitance) of the absorbing layers. Moreover, they have developed a model that describes the relation between humidity and the electrical parameters of the moisture-sensitive layer. Despite intensive research, absorption sensors still do not meet the requirements for high accuracy applications. The dew-point temperature method is more appropriate, since it uses the accurately known relation between temperature and saturation vapour pressure in air. When an object exposed to humid air is cooled down below the dew-point water vapour condenses as drops on its cold surface. The temperature can be kept exactly at the dew point by controlling the amount of dew (equilibrium between evaporation and condensation). In most dew-point hygrometers dew is detected with optical or capacitive means. In the former the dew drops on a reflective surface (chilled mirror) scatter incident light, and the capacitive method uses the change in capacitance due to the large dielectric constant of liquid water (80) compared to air (1). Kunze et al, in the fourth paper of this special feature, use another property of water to detect dew: the relatively high value of the thermal capacitance of liquid water. In traditional technology this method would not be sensitive enough, but with MEMS technology a sufficient detectivity of dew can be achieved, which is demonstrated in this paper. A control system keeps the temperature of the substrate just at the dew-point temperature, the latter being measured by an on-chip diode. The accuracy achieved is comparable with traditional dew-point hygrometers. These four papers in this issue are nice examples of research leading to significant advances in hygrometry. References [1] Wexler A (ed) 1965 Humidity and Moisture. Vol. I: Principles and Methods of Measuring Humidity in Gases; Vol. II: Applications; Vol. III: Fundamentals and Standards; Vol. IV: Principles and Methods of Measuring Moisture in Liquids and Solids (New York: Reinhold) [2] Sonntag D 1966-1968 Hygrometrie (Berlin: Akademie Verlag)
Measurement of precipitation using lysimeters
NASA Astrophysics Data System (ADS)
Fank, Johann; Klammler, Gernot
2013-04-01
Austria's alpine foothill aquifers contain important drinking water resources, but are also used intensively for agricultural production. These groundwater bodies are generally recharged by infiltrating precipitation. A sustainable water resources management of these aquifers requires quantifying real evapotranspiration (ET), groundwater recharge (GR), precipitation (P) and soil water storage change (ΔS). While GR and ΔS can be directly measured by weighable lysimeters and P by separate precipitation gauges, ET is determined by solving the climatic water balance ET = P GR ± ΔS. According to WMO (2008) measurement of rainfall is strongly influenced by precipitation gauge errors. Most significant errors result from wind loss, wetting loss, evaporation loss, and due to in- and out-splashing of water. Measuring errors can be reduced by a larger area of the measuring gaugés surface and positioning the collecting vessel at ground level. Modern weighable lysimeters commonly have a surface of 1 m², are integrated into their typical surroundings of vegetation cover (to avoid oasis effects) and allow scaling the mass change of monolithic soil columns in high measuring accuracy (0.01 mm water equivalent) and high temporal resolution. Thus, also precipitation can be quantified by measuring the positive mass changes of the lysimeter. According to Meissner et al. (2007) also dew, fog and rime can be determined by means of highly precise weighable lysimeters. Furthermore, measuring precipitation using lysimeters avoid common measuring errors (WMO 2008) at point scale. Though, this method implicates external effects (background noise, influence of vegetation and wind) which affect the mass time series. While the background noise of the weighing is rather well known and can be filtered out of the mass time series, the influence of wind, which blows through the vegetation and affects measured lysimeter mass, cannot be corrected easily since there is no clear relation between wind speeds and the measured outliers of lysimeter mass. Moreover, the influence of wind seems to be varying for different lysimeters. At the agricultural test site Wagna, Austria, two precipitation gauges in high temporal resolution (weighing-recording gauge and tipping-bucket gauge; both 200 cm² surface; measuring height 1.5 m) are installed. Furthermore, mass time series of various lysimeters cultivated with different vegetation is also available for the same location. Appropriate methods to compensate the influence of wind on measuring precipitation using lysimeters are investigated and results between the different measuring devices are compared. Results show that precipitation measured with lysimeters is generally higher, especially compared to the weighing-recording gauge. In addition it is detected that also the data interval of lysimeter mass time series used for quantifying precipitation (e.g., 1 day, 1 hour, 30 minutes, 10 minutes) is a crucial factor and influences the result. Summarizing, the potential of using highly precise weighable lysimeters for measuring precipitation at the point scale is rather high. However, methods used to compensate external effects on lysimeter weighing have to be enhanced for a global application of using lysimeters as precipitation gauges. Meissner, R., J. Seeger, H. Rupp, M. Seyfarth & H. Borg, 2007: Measurement of dew, fog, and rime with a high-precision gravitation Lysimeter. J. Plant Nutr. Soil Sci. 2007, 170, p. 335-344. WMO (World Meteorological Organization), 2008. Guide to Meteorological Instruments and Methods of Observation. WMO-No. 8, 140 pp.
Atmospheric Science Data Center
2015-11-25
... FSSP Gust Probe Hot-Wire Hygrometer Platinum Resistance PMS 2D-C Probe PRT-4 Pyranometer Pyrgeometer ... Parameters: Barometric Altitude Cloud Top Temperature Deiced Temperature Dew/Frost Point Temperature Droplet ...
Wet atmospheric generation apparatus
NASA Technical Reports Server (NTRS)
Hamner, Richard M. (Inventor); Allen, Janice K. (Inventor)
1990-01-01
The invention described relates to an apparatus for providing a selectively humidified gas to a camera canister containing cameras and film used in space. A source of pressurized gas (leak test gas or motive gas) is selected by a valve, regulated to a desired pressure by a regulator, and routed through an ejector (venturi device). A regulated source of water vapor in the form of steam from a heated reservoir is coupled to a low pressure region of the ejector which mixes with high velocity gas flow through the ejector. This mixture is sampled by a dew point sensor to obtain dew point thereof (ratio of water vapor to gas) and the apparatus adjusted by varying gas pressure or water vapor to provide a mixture at a connector having selected humidity content.
Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators
NASA Astrophysics Data System (ADS)
Benyon, R.; Vicente, T.
2012-09-01
The comparison of two high-range standard humidity generators used by Instituto Nacional de Técnica Aeroespacial to realize dew-point temperature in the range from -10 °C to +95 °C has been performed using state-of-the art transfer standards and measurement procedures, over their overlapping range from -10 °C to +75 °C. The aim of this study is to investigate the level of agreement between the two generators, to determine any bias, and to quantify the level of consistency of the two realizations. The measurement procedures adopted to minimize the effect of the influence factors due to the transfer standards are described, and the results are discussed in the context of the declared calibration and measurement capabilities (CMCs).
Bernstein, J A; Levin, L; Crandall, M S; Perez, A; Lanphear, B
2005-12-01
Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores that are potentially allergenic. The purpose of this pilot study was to investigate whether dehumidification in combination with high-efficiency particulate arrestance (HEPA) filtration is effective at reducing airborne mold spore levels in day care centers. Two day care centers within a 2-mile radius of each other were selected. Day care center A was 2 years old with eight rooms while day care center B was 15 years old with six rooms. A high efficiency Santa Fe dehumidification unit equipped with a HEPA filter was installed in half the rooms (intervention) of each day care facility. Electronic HOBO data loggers continuously measured outdoor and indoor room dew point and temperature every 2 h throughout the study. Dew point and airborne fungal spore measurements from selected rooms with controlled air conditions were analyzed by comparing baseline measurements to those obtained at subsequent time periods over 1 year. Regression models accounted for correlations between measurements in the same room over time. Intervention resulted in a lowered average dew point from baseline by 8.8 degrees C compared with a decrease of 7.1 degrees C in non-intervention rooms across all time periods in both facilities (P<0.001). Fungal analyses demonstrated lower baseline (P=0.06) and follow-up means in intervention rooms (P<0.05), however the change from baseline to end of follow-up differed between intervention and non-intervention rooms in the two facilities. Log transformation was applied to approximate normality of fungal measurements. Dehumidification with HEPA filtration was effective at controlling indoor dew point in both facilities and at reducing airborne culturable fungal spore levels in one of the two facilities. These preliminary results provide a scientific rationale for using this intervention in future studies designed to investigate the impact of indoor mold exposure on health outcomes. Poor indoor air quality is a recognized cause or contributing factor to health effects. Dampness and humidity have been linked to upper and lower respiratory symptoms in children and adults. This study indicates that reducing indoor relative humidity and airborne mold spore levels using high-efficiency dehumidification units equipped with HEPA filtration is feasible even in work facilities such as day care centers where traffic in and out of the building is difficult to regulate. Clinicians should emphasize to their patients the importance of dehumidification and HEPA filtration to improve indoor air quality in the home and workplace.
Use of Cometabolic Air Sparging to Remediate Chloroethene-Contaminated Groundwater Aquifers
2001-07-31
sampling event, the temperature, dew point , and relative humidity of the soil gas were analyzed using a Control Company Digital Hygrometer/Thermometer...4.2.1.3 Groundwater and Soil- Gas Multi-Level Monitoring Points .................... 20 4.2.1.4 Groundwater Monitoring Wells...C-1 APPENDIX D: SOIL- GAS MONITORING POINT DATA........................................................D-1 APPENDIX E: HISTORICAL
Validation and results of a scale model of dew deposition in urban environments
NASA Astrophysics Data System (ADS)
Richards, K.; Oke, T. R.
2002-12-01
There is growing interest in urban dew and its significance in questions of urban climate and air pollution deposition, but little research has been undertaken to study it. In this study, a generic, urban residential neighbourhood is modelled out-of-doors at a scale of 0.125, using three wooden houses (1.08 m tall), a concrete pavement (1.0 m in width), a grassed park (7.5 m in half-width) and several small trees (up to 1.5 m tall). The thermal inertia of each house is inflated, according to the internal thermal mass (ITM) approach, so that nocturnal surface temperatures are conserved. First-order validation was achieved through comparison with data collected at nearby full-scale sites in Vancouver, BC, Canada. Moisture accumulation (measured by blotting on grass and by lysimetry) is found to be primarily controlled by nocturnal weather conditions and the intrinsic nature of each substrate, e.g. dewfall is abundant on nights with few clouds and light winds, and on surfaces such as grass and asphalt-shingle roofs, which cool rapidly after sunset. However, these responses are modified by location effects related to the net radiation balance of the surface, which itself is strongly linked to site geometry as expressed by sky view factor and whether surfaces are isolated from heat sources. The dominant mechanism is argued to be the systematic increase in longwave radiation loss that is associated with increased sky view. Results agree with those observed at the full scale and suggest that maps of sky view factor, and knowledge of dew at an open site, can potentially be used to create maps of dew distribution in urban and other complex environments.
40 CFR 91.313 - Analyzers required.
Code of Federal Regulations, 2012 CFR
2012-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
40 CFR 90.313 - Analyzers required.
Code of Federal Regulations, 2013 CFR
2013-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
40 CFR 90.313 - Analyzers required.
Code of Federal Regulations, 2011 CFR
2011-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
40 CFR 91.313 - Analyzers required.
Code of Federal Regulations, 2014 CFR
2014-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
40 CFR 91.313 - Analyzers required.
Code of Federal Regulations, 2013 CFR
2013-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
40 CFR 91.313 - Analyzers required.
Code of Federal Regulations, 2011 CFR
2011-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
40 CFR 90.313 - Analyzers required.
Code of Federal Regulations, 2014 CFR
2014-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
40 CFR 90.313 - Analyzers required.
Code of Federal Regulations, 2012 CFR
2012-07-01
... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...
Analysis of the Dryden Wet Bulb GLobe Temperature Algorithm for White Sands Missile Range
NASA Technical Reports Server (NTRS)
LaQuay, Ryan Matthew
2011-01-01
In locations where workforce is exposed to high relative humidity and light winds, heat stress is a significant concern. Such is the case at the White Sands Missile Range in New Mexico. Heat stress is depicted by the wet bulb globe temperature, which is the official measurement used by the American Conference of Governmental Industrial Hygienists. The wet bulb globe temperature is measured by an instrument which was designed to be portable and needing routine maintenance. As an alternative form for measuring the wet bulb globe temperature, algorithms have been created to calculate the wet bulb globe temperature from basic meteorological observations. The algorithms are location dependent; therefore a specific algorithm is usually not suitable for multiple locations. Due to climatology similarities, the algorithm developed for use at the Dryden Flight Research Center was applied to data from the White Sands Missile Range. A study was performed that compared a wet bulb globe instrument to data from two Surface Atmospheric Measurement Systems that was applied to the Dryden wet bulb globe temperature algorithm. The period of study was from June to September of2009, with focus being applied from 0900 to 1800, local time. Analysis showed that the algorithm worked well, with a few exceptions. The algorithm becomes less accurate to the measurement when the dew point temperature is over 10 Celsius. Cloud cover also has a significant effect on the measured wet bulb globe temperature. The algorithm does not show red and black heat stress flags well due to shorter time scales of such events. The results of this study show that it is plausible that the Dryden Flight Research wet bulb globe temperature algorithm is compatible with the White Sands Missile Range, except for when there are increased dew point temperatures and cloud cover or precipitation. During such occasions, the wet bulb globe temperature instrument would be the preferred method of measurement. Out of the 30 dates examined, 23 fell under the category of having good accuracy.
Silva, Shayenne Olsson Freitas; Ferreira de Mello, Cecilia; Figueiró, Ronaldo; de Aguiar Maia, Daniele; Alencar, Jeronimo
2018-04-01
The Atlantic Rainforest of South America is one of the major biodiversity hotspots of the world and serves as a place of residence for a wide variety of Culicidae species. Mosquito studies in the natural environment are of considerable importance because of their role in transmitting pathogens to both humans and other vertebrates. Community diversity can have significant effects on the risk of their disease transmission. The objective of this study was to understand the distribution of mosquito communities using oviposition traps in a region of the Atlantic Forest. Sampling was carried out in Bom Retiro Private Natural Reserve (RPPNBR), located in Casimiro de Abreu, Rio de Janeiro, using oviposition traps, which were set in the forest environment, from October 2015 to December 2016. The canonical correspondence analysis was used to assess the influence of the climatic variables (precipitation, maximum dew point, and direction) throughout the seasons on the population density of the mosquito species. The results showed that population density was directly influenced by climatic variables, which acted as a limiting factor for the mosquito species studied. The climatic variables that were significantly correlated with the density of the mosquito species were precipitation, maximum dew point, and direction. Haemagogus janthinomys was positively correlated with the three climatic variables, whereas Haemagogus leucocelaenus was positively correlated with precipitation and maximum dew point, and negatively correlated with direction.
NASA Astrophysics Data System (ADS)
Rusticucci, Matilde; Bettolli, Laura M.; de los Angeles Harris, M.
2002-02-01
The aim of this paper is to study the relationships between hospital emergencies and weather conditions by analysing summer and winter cases of patients requiring attention at the emergency room of a hospital in the city of Buenos Aires, Argentina. Hospital data have been sorted into seven different diagnostic groups as follows: (1) respiratory, cardiovascular and chest-pain complaints; (2) digestive, genitourinary and abdominal complaints; (3) neurological and psychopathological disorders; (4) infections; (5) contusion and crushing, bone and muscle complaints; (6) skin and allergies and (7) miscellaneous complaints. In general, there is an increase of 16.7% in winter while, for group 2 and group 6, there are more patients in summer, 54% and 75% respectively. In summer, the total number of patients for group 6 shows a significant positive correlation with temperature and dew-point temperature, and a negative correlation with the sea-level pressure for the same day. In winter, the same relationship exists, however its correlation is not as strong. The lags observed between these three variables: maximum dew-point temperature, maximum temperature, minimum air pressure and the peaks in admissions are 1, 2 and 4 days respectively. In winter, increases in temperature and dew point and decreases in pressure are followed by a peak in admissions for group 2. In winter, there are significantly more cases in group 5 on warm, dry days and on warm, wet days in the summer.
NASA Astrophysics Data System (ADS)
Heinonen, Martti
2010-01-01
The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
NASA Astrophysics Data System (ADS)
Voigtländer, Jens; Niedermeier, Dennis; Siebert, Holger; Shaw, Raymond; Schumacher, Jörg; Stratmann, Frank
2017-04-01
To improve the fundamental and quantitative understanding of the interactions between cloud microphysical and turbulent processes, the Leibniz Institute for Tropospheric Research (TROPOS) has built up a new humid wind tunnel (LACIS-T). LACIS-T allows for the investigation of cloud microphysical processes, such as cloud droplet activation and freezing, under-well defined thermodynamic and turbulent flow conditions. It therewith allows for the straight forward continuation, extension, and completion of the cloud microphysics related investigations carried out at the Leipzig Aerosol Cloud Interaction Simulator (LACIS) under laminar flow conditions. Characterization of the wind tunnel with respect to flow, thermodynamics, and droplet microphysics is carried out with probes mounted inside (pitot tube and hot-wire anemometer for mean velocity and fluctuations, Pt100 sensor for mean temperature, cold-wire sensor for temperature fluctuations is in progress, as well as a dew-point mirror for mean water vapor concentration, a Lyman-alpha sensor for water vapor fluctuations is in progress) the measurement section, and from outside with optical detection methods (a laser light sheet is available for cloud droplet visualization, a digital holography system for detection of cloud droplet size distributions will be installed for tests in February 2017), respectively. Computational fluid dynamics (CFD) simulations have been carried out for defining suitable experimental conditions and assisting the interpretation of the experimental data. In this work, LACIS-T, its fundamental operating principle, and first preliminary results from ongoing characterization efforts will be presented.
Urticaceae pollen concentration in the atmosphere of North Western Spain.
Vega-Maray, Ana Maria; Valencia-Barrera, Rosa; Fernandez-Gonzalez, Delia; Fraile, Roberto
2003-01-01
Plants of the Urticaceae family can develop into a pest on soils enriched with nitrogen. Urticaceae pollen is a biohazard because it elicits severe pollinosis. Pollen grains were sampled by using a Lanzoni seven-day-recording trap from February 1995-December 2000 in the atmosphere of the city of Ponferrada (Leon, North Western Spain). The Spearman test was used to analyse the statistical correlation between Urticaceae pollen and certain meteorological factors in different main pollination periods. Maximum values are reached in June and July, minimum levels are recorded in January and December. The parameters bearing the greatest positive influence on the occurrence of Urticaceae pollen grains are: temperature (maximum, minimum and mean), humidity (absolute, wet-bulb temperature, dew point and mixing ratio) and south western wind direction; negative parameters are: relative humidity, rainfall and period without wind. The highest correlation coefficients were obtained with temperature and wet-bulb. Absolute humidity and wet-bulb temperature yielded better correlation than relative humidity; hence, these two parameters must be included in this type of study. The use of one main pollination period or another in statistical analysis has an influence on the coefficient value. The behaviour of the pollen grains in the atmosphere during the year also influences the results.
A Comparison of the Forecast Skills among Three Numerical Models
NASA Astrophysics Data System (ADS)
Lu, D.; Reddy, S. R.; White, L. J.
2003-12-01
Three numerical weather forecast models, MM5, COAMPS and WRF, operating with a joint effort of NOAA HU-NCAS and Jackson State University (JSU) during summer 2003 have been chosen to study their forecast skills against observations. The models forecast over the same region with the same initialization, boundary condition, forecast length and spatial resolution. AVN global dataset have been ingested as initial conditions. Grib resolution of 27 km is chosen to represent the current mesoscale model. The forecasts with the length of 36h are performed to output the result with 12h interval. The key parameters used to evaluate the forecast skill include 12h accumulated precipitation, sea level pressure, wind, surface temperature and dew point. Precipitation is evaluated statistically using conventional skill scores, Threat Score (TS) and Bias Score (BS), for different threshold values based on 12h rainfall observations whereas other statistical methods such as Mean Error (ME), Mean Absolute Error(MAE) and Root Mean Square Error (RMSE) are applied to other forecast parameters.
The 1979 Southeastern Virginia Urban Plume Study (SEV-UPS): Surface and airborne studies
NASA Technical Reports Server (NTRS)
White, J. H.; Eaton, W. C.; Saeger, M. L.; Strong, R. B.; Tommerdahl, J. B.
1980-01-01
The operation of two surface monitoring stations (one in downtown Norfolk, Virginia, one south of the city near the Great Dismal Swamp) and the collection of 40 hours of airborne measurements is described. Surface site measurements of ozone, oxides of nitrogen, sulfur dioxide, temperature, dew point, b sub seat, and condensation nuclei were made. Instrument calibrations, quality assurance audits, and preliminary data analysis in support of the Urban Plume Study were also made. The air pollution problems that were addressed are discussed. Data handling procedures followed for the surface stations are presented. The operation of the aircraft sampling platform is described. Aircraft sampling procedures are discussed. A preliminary descriptive analysis of the aircraft data is given along with data or plots for surface sites, airborne studies, hydrocarbon species, and instrument performance audits. Several of the aircraft flights clearly show the presence of an urban ozone plume downwind of Norfolk in the direction of the mean wind flow.
Simulating soybean canopy temperature as affected by weather variables and soil water potential
NASA Technical Reports Server (NTRS)
Choudhury, B. J.
1982-01-01
Hourly weather data for several clear sky days during summer at Phoenix and Baltimore which covered a wide range of variables were used with a plant atmosphere model to simulate soybean (Glycine max L.) leaf water potential, stomatal resistance and canopy temperature at various soil water potentials. The air and dew point temperatures were found to be the significant weather variables affecting the canopy temperatures. Under identical weather conditions, the model gives a lower canopy temperature for a soybean crop with a higher rooting density. A knowledge of crop rooting density, in addition to air and dew point temperatures is needed in interpreting infrared radiometric observations for soil water status. The observed dependence of stomatal resistance on the vapor pressure deficit and soil water potential is fairly well represented. Analysis of the simulated leaf water potentials indicates overestimation, possibly due to differences in the cultivars.
Use of dew-point detection for quantitative measurement of sweating rate
NASA Technical Reports Server (NTRS)
Brengelmann, G. L.; Mckeag, M.; Rowell, L. B.
1975-01-01
A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.
The change of steel surface chemistry regarding oxygen partial pressure and dew point
NASA Astrophysics Data System (ADS)
Norden, Martin; Blumenau, Marc; Wuttke, Thiemo; Peters, Klaus-Josef
2013-04-01
By investigating the surface state of a Ti-IF, TiNb-IF and a MnCr-DP after several series of intercritical annealing, the impact of the annealing gas composition on the selective oxidation process is discussed. On behalf of the presented results, it can be concluded that not the general oxygen partial pressure in the annealing furnace, which is a result of the equilibrium reaction of water and hydrogen, is the main driving force for the selective oxidation process. It is shown that the amounts of adsorbed gases at the strip surface and the effective oxygen partial pressure resulting from the adsorbed gases, which is mainly dependent on the water content of the annealing furnace, is driving the selective oxidation processes occurring during intercritical annealing. Thus it is concluded, that for industrial applications the dew point must be the key parameter value for process control.
Evaluation of the Long-Term Stability and Temperature Coefficient of Dew-Point Hygrometers
NASA Astrophysics Data System (ADS)
Benyon, R.; Vicente, T.; Hernández, P.; De Rivas, L.; Conde, F.
2012-09-01
The continuous quest for improved specifications of optical dew-point hygrometers has raised customer expectations on the performance of these devices. In the absence of a long calibration history, users with a limited prior experience in the measurement of humidity, place reliance on manufacturer specifications to estimate long-term stability. While this might be reasonable in the case of measurement of electrical quantities, in humidity it can lead to optimistic estimations of uncertainty. This article reports a study of the long-term stability of some hygrometers and the analysis of their performance as monitored through regular calibration. The results of the investigations provide some typical, realistic uncertainties associated with the long-term stability of instruments used in calibration and testing laboratories. Together, these uncertainties can help in establishing initial contributions in uncertainty budgets, as well as in setting the minimum calibration requirements, based on the evaluation of dominant influence quantities.
Measurement of evaporative water loss in small animals by dew-point hygrometry.
Bernstein, M H; Hudson, D M; Stearns, J M; Hoyt, R W
1977-08-01
This paper presents the procedures and equations to be utilized for measurement of evaporative water loss (mw), by use of the dew-point hygrometer, in small animals exposed to air containing water vapor in an open-flow system. The system accounted accurately for the water evaporated from a bubble flask. In addition, hygrometric measurements of pulmocutaneous mw in pigeons (Columba livia, mean mass 0.31 kg) agreed closely with simultaneous gravimetric measurements, utilizing a desiccant in the sample stream, in a manner independently of air temperature (Ta, 20 or 40 degrees C), ambient water vapor pressure (PW, 4-16 10(2) Pa), or mw (5-66 mg-min-1). Evaporation in pigeons was independent of PW at 20 degrees C, but increased with decreasing PW at 40 degrees C, suggesting differences in ventilatory adjustments to changes in PW at the two temperatures.
Paczesny, Daniel; Rapiejko, Piotr; Weremczuk, Jerzy; Jachowicz, Ryszard; Jurkiewicz, Dariusz
2007-01-01
Aim of this study was to check at the hospital the dew point hygrometer for fast measurement of air humidity in upper airways. The nose ability to humidification of inspired air and partially recover moisture from expired air was evaluated. Measurements from respiration through the nose and oral cavity were compared. The study was carried out in a group of 30 people (8 female and 22 male), age group 18 to 70 (mean age: 37 years old). In 22 of the participants there were no deviation from normal state in laryngologic examination, while in 4 participants nasal septum deviation without imaired nasal; oatency was found, in other 3--nasal vonchae hyperthrophy and in 1--nasal polips (grade I). The measurements of air humidity in upper air ways was done using specially designed and constructed measurement system. The air inspired through the nose and oral cavity is humidified. For typical external conditions (T = 22 degrees C i RH = 50%) the nose humidifies inspired air two times better then oral cavity (short time range of measurement approximately 1 min). Moisture from expired air through the nose is partially recovered (for patients with regular patency is 25% of the value of humidifying of inspired air). The oral cavity does not have ability to partially recovery moisture form expired air. The paper presented fast dew point hygrometer based on semiconductor microsystems for measurement humidity in inspired and expired air through the nose and oral cavity. Presented system can be a proper instrument for evaluation of nasal functions.
Measurement Uncertainty of Dew-Point Temperature in a Two-Pressure Humidity Generator
NASA Astrophysics Data System (ADS)
Martins, L. Lages; Ribeiro, A. Silva; Alves e Sousa, J.; Forbes, Alistair B.
2012-09-01
This article describes the measurement uncertainty evaluation of the dew-point temperature when using a two-pressure humidity generator as a reference standard. The estimation of the dew-point temperature involves the solution of a non-linear equation for which iterative solution techniques, such as the Newton-Raphson method, are required. Previous studies have already been carried out using the GUM method and the Monte Carlo method but have not discussed the impact of the approximate numerical method used to provide the temperature estimation. One of the aims of this article is to take this approximation into account. Following the guidelines presented in the GUM Supplement 1, two alternative approaches can be developed: the forward measurement uncertainty propagation by the Monte Carlo method when using the Newton-Raphson numerical procedure; and the inverse measurement uncertainty propagation by Bayesian inference, based on prior available information regarding the usual dispersion of values obtained by the calibration process. The measurement uncertainties obtained using these two methods can be compared with previous results. Other relevant issues concerning this research are the broad application to measurements that require hygrometric conditions obtained from two-pressure humidity generators and, also, the ability to provide a solution that can be applied to similar iterative models. The research also studied the factors influencing both the use of the Monte Carlo method (such as the seed value and the convergence parameter) and the inverse uncertainty propagation using Bayesian inference (such as the pre-assigned tolerance, prior estimate, and standard deviation) in terms of their accuracy and adequacy.
Seven-Year SSM/I-Derived Global Ocean Surface Turbulent Fluxes
NASA Technical Reports Server (NTRS)
Chou, Shu-Hsien; Shie, Chung-Lin; Atlas, Robert M.; Ardizzone, Joe
2000-01-01
A 7.5-year (July 1987-December 1994) dataset of daily surface specific humidity and turbulent fluxes (momentum, latent heat, and sensible heat) over global oceans has been retrieved from the Special Sensor Microwave/Imager (SSM/I) data and other data. It has a spatial resolution of 2.0 deg.x 2.5 deg. latitude-longitude. The retrieved surface specific humidity is generally accurate over global oceans as validated against the collocated radiosonde observations. The retrieved daily wind stresses and latent heat fluxes show useful accuracy as verified by those measured by the RV Moana Wave and IMET buoy in the western equatorial Pacific. The derived turbulent fluxes and input variables are also found to agree generally with the global distributions of annual-and seasonal-means of those based on 4-year (1990-93) comprehensive ocean-atmosphere data set (COADS) with adjustment in wind speeds and other climatological studies. The COADS has collected the most complete surface marine observations, mainly from merchant ships. However, ship measurements generally have poor accuracy, and variable spatial coverages. Significant differences between the retrieved and COADS-based are found in some areas of the tropical and southern extratropical oceans, reflecting the paucity of ship observations outside the northern extratropical oceans. Averaged over the global oceans, the retrieved wind stress is smaller but the latent heat flux is larger than those based on COADS. The former is suggested to be mainly due to overestimation of the adjusted ship-estimated wind speeds (depending on sea states), while the latter is suggested to be mainly due to overestimation of ship-measured dew point temperatures. The study suggests that the SSM/I-derived turbulent fluxes can be used for climate studies and coupled model validations.
Chemical composition of dew in Amman, Jordan
NASA Astrophysics Data System (ADS)
Jiries, Anwar
Twenty-six dew samples were collected on a glass surface from an urbanized area in Amman city during the period October 1999 to June 2000. They were analyzed for the major ions (Cl, SO 4, NO 3, Ca, Mg, Na, K and NH 4) in addition to three heavy metals (Pb, Cd and Co). Rain samples were collected for the same period and compared to the chemical constituents of dew. It was found that both rain and dew samples were of almost neutral acidity due to the buffering effect of CaCO 3. Dew composition was mainly from CaSO 4 solution due to conversion of CaCO 3 to CaSO 4 when left exposed to a sulfate-rich atmosphere. The total dissolved solids were higher in dew than rain samples of the same period. This was attributed to higher evaporation effect on dew than rain. The heavy metal content in dew is highest during the cold winter season (December-March) due to excess fossil fuel combustion for heating purposes in this period. The heavy metal content in dew was lower than that for rain during the same period because of the shorter period of dew formation than rainwater.
MODIS Atmospheric Data Handler
NASA Technical Reports Server (NTRS)
Anantharaj, Valentine; Fitzpatrick, Patrick
2008-01-01
The Moderate Resolution Imaging Spectroradiometer (MODIS) Atmosphere Data Handler software converts the HDF data to ASCII format, and outputs: (1) atmospheric profiles of temperature and dew point and (2) total precipitable water. Quality-control data are also considered in the export procedure.
Theoretical and testing performance of an innovative indirect evaporative chiller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jiang, Yi; Xie, Xiaoyun
2010-12-15
An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirectmore » evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller successfully satisfy the indoor air conditioning load for the demo building. The indirect evaporative chiller has a potentially wide application in dry regions, especially for large scale commercial buildings. Finally, this paper presented the geographic regions suitable for the technology worldwide. (author)« less
Electronic leaf wetness duration sensor: why it should be painted.
Sentelhas, P C; Monteiro, J E B A; Gillespie, T J
2004-05-01
The purpose of this study was to compare and evaluate the performance of electronic leaf wetness duration (LWD) sensors in measuring LWD in a cotton crop canopy when unpainted and painted sensors were used. LWD was measured with flat, printed-circuit wetness sensors, and the data were divided into two periods of 24 days: from 18 December 2001 to 10 January 2002, when the sensors were unpainted, and from 20 January to 13 February 2002, when the sensors were painted with white latex paint (two coats of paint). The data analysis included evaluating the coefficient of variation (CV%) among the six sensors for each day, and the relationship between the measured LWD (mean for the six sensors) and the number of hours with dew point depression under 2 degrees C, used as an indicator of dew presence. The results showed that the painting markedly reduced the CV% values. For the unpainted sensors the CV% was on average 67% against 9% for painted sensors. For the days without rainfall this reduction was greater. Comparing the sensor measurements to another estimator of LWD, in this case the number of hours with dew point depression under 2 degrees C, it was also observed that painting improved not only the precision of the sensors but also their sensitivity, because it increases the ability of the sensor to detect and measure the wetness promoted by small water droplets.
Urban dew and rain in Paris, France: Occurrence and physico-chemical characteristics
NASA Astrophysics Data System (ADS)
Beysens, D.; Mongruel, A.; Acker, K.
2017-06-01
This paper summarizes one year (April 2011 to March 2012) measurements on planar condensing surfaces of dew and rain events and related physico-chemical characteristics in the urban environment of Paris (city center). Yearly collected water was 3.48 mm for dew (63 events) and 593 mm for rain (146 events). The latter value compares well with rain data (547 mm and 107 events) collected within 12 km at Paris-Orly airport. An estimation of dew yield based on meteo data gives 2.35 mm and 74 events, to be compared with 17.11 mm and 196 events at Paris-Orly. These differences highlight the large reduction in dew events and dew yields in an urban area as compared to a close rural-like area. This reduction is not due to a sky view reduction but to heat island that increases air temperature and decreases relative humidity. Analysis of dew (34) and rain (77) samples were done concerning pH, electrical conductivity (EC), major anions and cations as well as selected trace metals and other minor ions. Mean pH values are found similar for both, dew (6.5) and rain (6.1), rain being slightly more acidic than dew. The mean dew total ionic content (TIC 1.8 meq/l) and EC value (124 μS/cm) are about four times that of rain (0.45 meq/l; 35 μS/cm), meaning that total dissolved solids in dew is nearly four times that in rain. Sulfate and nitrate are the most acidifying components, calcium the most neutralizing constituent with ratio of mean total acidity/total alkalinity comparable for dew and rain ( 0.9). Sulfate and nitrate have mainly anthropogenic sources, whereas chloride and magnesium are mostly connected with marine air masses. Dew is a considerable factor of wet deposition of pollutants; dew and rain ion concentrations, however, meet the WHO requirements for drinking water.
NASA Astrophysics Data System (ADS)
Otero, Federico; Norte, Federico; Araneo, Diego
2018-01-01
The aim of this work is to obtain an index for predicting the probability of occurrence of zonda event at surface level from sounding data at Mendoza city, Argentine. To accomplish this goal, surface zonda wind events were previously found with an objective classification method (OCM) only considering the surface station values. Once obtained the dates and the onset time of each event, the prior closest sounding for each event was taken to realize a principal component analysis (PCA) that is used to identify the leading patterns of the vertical structure of the atmosphere previously to a zonda wind event. These components were used to construct the index model. For the PCA an entry matrix of temperature ( T) and dew point temperature (Td) anomalies for the standard levels between 850 and 300 hPa was build. The analysis yielded six significant components with a 94 % of the variance explained and the leading patterns of favorable weather conditions for the development of the phenomenon were obtained. A zonda/non-zonda indicator c can be estimated by a logistic multiple regressions depending on the PCA component loadings, determining a zonda probability index \\widehat{c} calculable from T and Td profiles and it depends on the climatological features of the region. The index showed 74.7 % efficiency. The same analysis was performed by adding surface values of T and Td from Mendoza Aero station increasing the index efficiency to 87.8 %. The results revealed four significantly correlated PCs with a major improvement in differentiating zonda cases and a reducing of the uncertainty interval.
New Submersed Chamber for Calibration of Relative Humidity Instruments at HMI/FSB-LPM
NASA Astrophysics Data System (ADS)
Sestan, D.; Zvizdic, D.; Sariri, K.
2018-02-01
This paper gives a detailed description of a new chamber designed for calibration of relative humidity (RH) instruments at Laboratory for Process Measurement (HMI/FSB-LPM). To the present time, the calibrations of RH instruments at the HMI/FSB-LPM were done by comparison method using a climatic chamber of large volume and calibrated dew point hygrometer with an additional thermometer. Since 2010, HMI/FSB-LPM in cooperation with Centre for Metrology and Accreditation in Finland (MIKES) developed the two primary dew point generators which cover the dew point temperature range between - 70 {°}C and 60 {°}C. In order to utilize these facilities for calibrations of the RH instruments, the new chamber was designed, manufactured and installed in the existing system, aiming to extend its range and reduce the related calibration uncertainties. The chamber construction allows its use in a thermostatic bath of larger volume as well as in the climatic chambers. In the scope of this paper, performances of the new chamber were tested while it was submersed in a thermostated bath. The chamber can simultaneously accommodate up to three RH sensors. In order to keep the design of the chamber simple, only cylindrical RH sensors detachable from display units can be calibrated. Possible optimizations are also discussed, and improvements in the design proposed. By using the new chamber, HMI/FSB-LPM reduced the expanded calibration uncertainties (level of confidence 95 %, coverage factor k=2) from 0.6 %rh to 0.25 %rh at 30 %rh (23 {°}C), and from 0.8 %rh to 0.53 %rh at 70 %rh (23 {°}C).
Weather forecasting based on hybrid neural model
NASA Astrophysics Data System (ADS)
Saba, Tanzila; Rehman, Amjad; AlGhamdi, Jarallah S.
2017-11-01
Making deductions and expectations about climate has been a challenge all through mankind's history. Challenges with exact meteorological directions assist to foresee and handle problems well in time. Different strategies have been investigated using various machine learning techniques in reported forecasting systems. Current research investigates climate as a major challenge for machine information mining and deduction. Accordingly, this paper presents a hybrid neural model (MLP and RBF) to enhance the accuracy of weather forecasting. Proposed hybrid model ensure precise forecasting due to the specialty of climate anticipating frameworks. The study concentrates on the data representing Saudi Arabia weather forecasting. The main input features employed to train individual and hybrid neural networks that include average dew point, minimum temperature, maximum temperature, mean temperature, average relative moistness, precipitation, normal wind speed, high wind speed and average cloudiness. The output layer composed of two neurons to represent rainy and dry weathers. Moreover, trial and error approach is adopted to select an appropriate number of inputs to the hybrid neural network. Correlation coefficient, RMSE and scatter index are the standard yard sticks adopted for forecast accuracy measurement. On individual standing MLP forecasting results are better than RBF, however, the proposed simplified hybrid neural model comes out with better forecasting accuracy as compared to both individual networks. Additionally, results are better than reported in the state of art, using a simple neural structure that reduces training time and complexity.
Measuring Humidity in Sealed Glass Encasements
NASA Technical Reports Server (NTRS)
West, James W.; Burkett, Cecil G.; Levine, Joel S.
2005-01-01
A technique has been devised for measuring the relative humidity levels in the protective helium/water vapor atmosphere in which the Declaration of Independence, the United States Constitution, and the Bill of Rights are encased behind glass panels on display at the National Archives in Washington, DC. The technique is noninvasive: it does not involve penetrating the encasements (thereby risking contamination or damage to the priceless documents) to acquire samples of the atmosphere. The technique could also be applied to similar glass encasements used to protect and display important documents and other precious objects in museums. The basic principle of the technique is straightforward: An encasement is maintained at its normal display or operating temperature (e.g., room temperature) while a portion of its glass front panel is chilled (see Figure 1) until condensed water droplets become visible on the inside of the panel. The relative humidity of the enclosed atmosphere can then be determined as a known function of the dew point, the temperature below which the droplets condense. Notwithstanding the straightforwardness of the basic principle, careful attention to detail is necessary to enable accurate determination of the dew point. In the initial application, the affected portion of the glass panel was cooled by contact with an aluminum plate that was cooled by a thermoelectric module, the exhaust heat of which was dissipated by a heat sink cooled by a fan. A thermocouple was used to measure the interior temperature of the aluminum plate, and six other thermocouples were used to measure the temperatures at six locations on the cooled outer surface of the glass panel (see Figure 2). Thermal grease was applied to the aluminum plate and the thermocouples to ensure close thermal contact. Power was supplied to the thermoelectric module in small increments, based on previous laboratory tests. A small flashlight and a magnifying glass were used to look for water droplets condensing on the inner surface of the glass. The temperature readings of the thermocouples were taken during cool-down and upon observing condensation. In determining the dew point, it was necessary to make a correction for the differences between the temperatures measured on the chilled outer surface of the glass and the temperature of the inner surface, where the condensation took place. The correction was derived from a laboratory test on a measurement setup that was nearly identical, except that the dew location on the inner surface was also instrumented with a thermocouple. The test showed that the temperature at the dew location on the inner surface of the glass panel was 0.9 C above the temperature determined from the measurements on the chilled outer surface of the panel.
Correlation of the protein structure and gelling properties in dried egg white products.
Handa, A; Hayashi, K; Shidara, H; Kuroda, N
2001-08-01
The relationship between protein structure and aggregation, as well as heat-induced gelling properties, of seven dried egg white (DEW) products was investigated. Strong correlations were found between average molecular weight and hydrophobicity plus surface SH groups of DEW-soluble protein aggregate (SPA). This suggests that hydrophobic interactions and disulfide bond formation between protein molecules were involved in the aggregation. The average molecular weight of DEW products with alkaline pHs was relatively higher than those with neutral pHs and the same degree of protein unfolding, probably because of more disulfide bond formation between protein molecules. In addition, strong correlations were found between hydrophobicity, surface SH groups plus average molecular weight of DEW-SPA, and physical properties of the gels from DEW products. These data indicated that controlling the aggregation of DEW proteins in the dry state is crucial to controlling the gelling properties of DEW.
Meteorologial Techniques (Revision 21 Feb 2007)
2003-06-13
Dissipation of Stratus Using Mixing Ratio and Temperature ------------------------- 2-12 Figure 2-27 Tropopause Method of Forecasting Cirrus...2-51 Figure 2-70 Bright Band Identification Using the WSR-88D...convective clouds using surface dew-point depressions --------------------- 2-11 Table 2-5 Aircraft category type
Nitric Oxide Measurement Study. Volume II. Probe Methods,
1980-05-01
case of the Task I study, it should be pointed out that at lower gas temperatures where much of the study was performed, the mass flow through the...third body as pointed out by Matthews, et al. (1977) but also dependent on the viscosity of the sampled gas for standard commercial units (Folsom and...substantially above the dew point (based on the maximum pressure in the sampling system and the initial water concentration) or (2) sample line and
Simulating sunflower canopy temperatures to infer root-zone soil water potential
NASA Technical Reports Server (NTRS)
Choudhury, B. J.; Idso, S. B.
1983-01-01
A soil-plant-atmosphere model for sunflower (Helianthus annuus L.), together with clear sky weather data for several days, is used to study the relationship between canopy temperature and root-zone soil water potential. Considering the empirical dependence of stomatal resistance on insolation, air temperature and leaf water potential, a continuity equation for water flux in the soil-plant-atmosphere system is solved for the leaf water potential. The transpirational flux is calculated using Monteith's combination equation, while the canopy temperature is calculated from the energy balance equation. The simulation shows that, at high soil water potentials, canopy temperature is determined primarily by air and dew point temperatures. These results agree with an empirically derived linear regression equation relating canopy-air temperature differential to air vapor pressure deficit. The model predictions of leaf water potential are also in agreement with observations, indicating that measurements of canopy temperature together with a knowledge of air and dew point temperatures can provide a reliable estimate of the root-zone soil water potential.
Water Potential in Excised Leaf Tissue
Nelsen, Charles E.; Safir, Gene R.; Hanson, Andrew D.
1978-01-01
Leaf water potential (Ψleaf) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Ψleaf values from the dew point hygrometer were too high. Agreement was improved by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Ψleaf values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status. PMID:16660227
NASA Astrophysics Data System (ADS)
Kürbis, K.; Mudelsee, M.; Tetzlaff, G.; Brázdil, R.
2009-09-01
For the analysis of trends in weather extremes, we introduce a diagnostic index variable, the exceedance product, which combines intensity and frequency of extremes. We separate trends in higher moments from trends in mean or standard deviation and use bootstrap resampling to evaluate statistical significances. The application of the concept of the exceedance product to daily meteorological time series from Potsdam (1893 to 2005) and Prague-Klementinum (1775 to 2004) reveals that extremely cold winters occurred only until the mid-20th century, whereas warm winters show upward trends. These changes were significant in higher moments of the temperature distribution. In contrast, trends in summer temperature extremes (e.g., the 2003 European heatwave) can be explained by linear changes in mean or standard deviation. While precipitation at Potsdam does not show pronounced trends, dew point does exhibit a change from maximum extremes during the 1960s to minimum extremes during the 1970s.
High-temperature phase relations and thermodynamics in the iron-lead-sulfur system
NASA Astrophysics Data System (ADS)
Eric, R. Hurman; Ozok, Hakan
1994-01-01
The PbS activities in FeS-PbS liquid mattes were obtained at 1100 °C and 1200 °C by the dew-point method. Negative deviations were observed, and the liquid-matte solutions were modeled by the Krupkowski formalism. The liquid boundaries of the FeS-PbS phase diagram were derived from the model equations yielding a eutectic temperature of 842 °C at X Pbs = 0.46. A phase diagram of the pseudobinary FeS-PbS was also verified experimentally by quenching samples equilibrated in evacuated and sealed silica capsules. No terminal solid solution ranges could be found. Within the Fe-Pb-S ternary system, the boundaries of the immiscibility region together with the tie-line distributions were established at 1200 °C. Activities of Pb were measured by the dew-point technique along the metal-rich boundary of the miscibility gap. Activities of Fe, Pb, and S, along the miscibility gap were also calculated by utilizing the bounding binary thermodynamics, phase equilibria, and tie-lines.
NASA Astrophysics Data System (ADS)
Jia, Rong-liang; Li, Xin-rong; Liu, Li-chao; Pan, Yan-xia; Gao, Yan-hong; Wei, Yong-ping
2014-11-01
Sand burial and dew deposition are two fundamental phenomena profoundly influencing biological soil crusts in desert areas. However, little information is available regarding the effects of sand burial on dew deposition on biological soil crusts in desert ecosystems. In this study, we evaluated the effects of sand burial at depths of 0 (control), 0.5, 1, 2 and 4 mm on dew formation and evaporation of three dominant moss crusts in a revegetated area of the Tengger Desert (Northern China) in 2010. The results revealed that sand burial significantly decreased the amount of dew deposited on the three moss crust types by acting as a semi-insulator retarding the dew formation and evaporation rates. The changes in surface temperature cannot fully explain the variations of the formation and evaporation rates of dew by moss crusts buried by sand. The extension of dew retention time was reflected by the higher dew ratios (the ratio of dew amount at a certain time to the maximum value in a daily course) in the daytime, and may to some extent have acted as compensatory mechanisms that diminished the negative effects of the reduction of dew amount induced by sand burial of moss crusts. The resistances to reduction of dewfall caused by sand burial among the three moss crusts were also compared and it was found that Bryum argenteum crust showed the highest tolerance, followed by crusts dominated by Didymodon vinealis and Syntrichia caninervis. This sequence corresponds well with the successional order of the three moss crusts in the revegetated area, thereby suggesting that resistance to reduction of dewfall may act as one mechanism by which sand burial drives the succession of moss crusts in desert ecosystems. This side effect of dew reduction induced by sand burial on biological soil crusts should be considered in future ecosystem construction and management of desert area.
Associations between ozone and morbidity using the Spatial Synoptic Classification system
2011-01-01
Background Synoptic circulation patterns (large-scale tropospheric motion systems) affect air pollution and, potentially, air-pollution-morbidity associations. We evaluated the effect of synoptic circulation patterns (air masses) on the association between ozone and hospital admissions for asthma and myocardial infarction (MI) among adults in North Carolina. Methods Daily surface meteorology data (including precipitation, wind speed, and dew point) for five selected cities in North Carolina were obtained from the U.S. EPA Air Quality System (AQS), which were in turn based on data from the National Climatic Data Center of the National Oceanic and Atmospheric Administration. We used the Spatial Synoptic Classification system to classify each day of the 9-year period from 1996 through 2004 into one of seven different air mass types: dry polar, dry moderate, dry tropical, moist polar, moist moderate, moist tropical, or transitional. Daily 24-hour maximum 1-hour ambient concentrations of ozone were obtained from the AQS. Asthma and MI hospital admissions data for the 9-year period were obtained from the North Carolina Department of Health and Human Services. Generalized linear models were used to assess the association of the hospitalizations with ozone concentrations and specific air mass types, using pollutant lags of 0 to 5 days. We examined the effect across cities on days with the same air mass type. In all models we adjusted for dew point and day-of-the-week effects related to hospital admissions. Results Ozone was associated with asthma under dry tropical (1- to 5-day lags), transitional (3- and 4-day lags), and extreme moist tropical (0-day lag) air masses. Ozone was associated with MI only under the extreme moist tropical (5-day lag) air masses. Conclusions Elevated ozone levels are associated with dry tropical, dry moderate, and moist tropical air masses, with the highest ozone levels being associated with the dry tropical air mass. Certain synoptic circulation patterns/air masses in conjunction with ambient ozone levels were associated with increased asthma and MI hospitalizations. PMID:21609456
40 CFR 86.346-79 - Alternative NOX measurement technique.
Code of Federal Regulations, 2012 CFR
2012-07-01
... following “alternative instrumentation” for both Diesel and gasoline-fueled engines. The “alternative instrumentation” shall consist of: (1) A heated sample line maintained above the dew point: (2) An NO2 to NO... the “alternative instrumentation”, where applicable, with the following exceptions: (1) Analyzer...
40 CFR 86.346-79 - Alternative NOX measurement technique.
Code of Federal Regulations, 2011 CFR
2011-07-01
... following “alternative instrumentation” for both Diesel and gasoline-fueled engines. The “alternative instrumentation” shall consist of: (1) A heated sample line maintained above the dew point: (2) An NO2 to NO... the “alternative instrumentation”, where applicable, with the following exceptions: (1) Analyzer...
40 CFR 86.346-79 - Alternative NOX measurement technique.
Code of Federal Regulations, 2010 CFR
2010-07-01
... following “alternative instrumentation” for both Diesel and gasoline-fueled engines. The “alternative instrumentation” shall consist of: (1) A heated sample line maintained above the dew point: (2) An NO2 to NO... the “alternative instrumentation”, where applicable, with the following exceptions: (1) Analyzer...
40 CFR 86.346-79 - Alternative NOX measurement technique.
Code of Federal Regulations, 2013 CFR
2013-07-01
... following “alternative instrumentation” for both Diesel and gasoline-fueled engines. The “alternative instrumentation” shall consist of: (1) A heated sample line maintained above the dew point: (2) An NO2 to NO... the “alternative instrumentation”, where applicable, with the following exceptions: (1) Analyzer...
Wind and flux measurements in a windfarm co-located with agricultural production (Invited)
NASA Astrophysics Data System (ADS)
Takle, E. S.; Prueger, J. H.; Rajewski, D. A.; Lundquist, J. K.; Aitken, M.; Rhodes, M. E.; Deppe, A. J.; Goodman, F. E.; Carter, K. C.; Mattison, L.; Rabideau, S. L.; Rosenberg, A. J.; Whitfield, C. L.; Hatfield, J.
2010-12-01
Co-locating wind farms in pre-existing agricultural fields represents multiple land uses for which there may be interactions. Agricultural producers have raised questions about the possible impact of changes in wind speed and turbulence on pollination, dew formation, and conditions favorable for diseases. During summer 2010 we measured wind speed and surface fluxes within a wind farm that was co-located with a landscape covered by corn and soybeans in central Iowa. We erected four 9.14 m towers in corn fields upwind and downwind of lines of 1.5 MW turbines. All towers were instrumented with sonic anemometers at 6.45 m above ground, three-cup anemometers at 9.06 m ,and two temperature and relative humidity probes at 5.30 and 9.06 m. In addition, LiCor 7500 CO2/H2O flux analyzers were mounted at 6.45 m on two towers. At the beginning of the field campaign (late June) the corn had a height of about 1.3 m and grew to about 2.2 m at maturity in late July. For a 2-week period beginning late June a vertically pointing lidar was located near a flux tower downwind of one of the turbines and collected horizontal winds from 40 m to 200 m above ground. Twenty-Hz data from the eddy covariance systems were recorded as were 5-min averaged values of wind speed, temperature, humidity, and fluxes of heat, momentum, moisture and CO2 day and night under a wide variety of weather conditions, including a two-week period when the turbines were shut down. Numerical simulations with the WRF (Weather Research and Forecast) model for select periods with no turbine influence provide opportunities for comparing modeled and measured values of surface conditions and vertical wind profiles. Results show clear evidence of changes in flow field conditions at the surface that influence fluxes. We will discuss diurnal changes in fluxes and influence of turbines. Lidar measurements of vertical profiles of wind speed compared against modeled undisturbed flow fields behind a turbine reveal significant momentum extraction and creation of regions of strong shear leading to mechanical generation of turbulence. Potential impacts on agricultural crops will be discussed.
Soil nutrients losses by wind erosion in a citrus crop at southeast Spain
NASA Astrophysics Data System (ADS)
Segovia, C.; Gómez, J. D.; Gallardo, P.; Lozano, F. J.; Asensio, C.
2017-06-01
The purpose of this study was to analyze the influence of wind erosion on the productivity of citric crops over gypsiric Fluvisols in Gador area (Almeria, SE Spain) by blowing air through a wind tunnel. Wind erosion varies considerably depending on time since the last tillage. This is because a physical crust forms after tilling which protects the soil from wind. Crust formation in the study area is strongly favored by dew, which causes them to form in around a week. The repeated measurements ANOVA, as a nonparametric alternative to the ANOVA, using the Geiiser method and the Friedman test shows significant differences ( P ≤ 0.05) in the fractions of very fine sand and coarse silt, which confirmed that very fine sand and coarse silt are the fractions most susceptible to loss from wind. The same statistical analysis for fertility showed smaller differences in organic carbon and K2O content, while N and P2O5 increased. Nutrients lost from wind imply an additional fertilization cost for a crop to be economically feasible. The cost of this restoration of nutrients lost from the soil because of wind erosion was based on experimental data taken in crusted soil and immediately after tilling. Losses in organic matter (O.M.), N, P2O5 and K2O were estimated based on the cost of fertilizers most commonly used in the area.
NASA Technical Reports Server (NTRS)
Choudhury, B. J.; Idso, S. B.; Reginato, R. J.
1986-01-01
Accurate estimates of evaporation over field-scale or larger areas are needed in hydrologic studies, irrigation scheduling, and meteorology. Remotely sensed surface temperature might be used in a model to calculate evaporation. A resistance-energy balance model, which combines an energy balance equation, the Penman-Monteith (1981) evaporation equation, and van den Honert's (1948) equation for water extraction by plant roots, is analyzed for estimating daily evaporation from wheat using postnoon canopy temperature measurements. Additional data requirements are half-hourly averages of solar radiation, air and dew point temperatures, and wind speed, along with reasonable estimates of canopy emissivity, albedo, height, and leaf area index. Evaporation fluxes were measured in the field by precision weighing lysimeters for well-watered and water-stressed wheat. Errors in computed daily evaporation were generally less than 10 percent, while errors in cumulative evaporation for 10 clear sky days were less than 5 percent for both well-watered and water-stressed wheat. Some results from sensitivity analysis of the model are also given.
Sea Fog Forecasting with Lagrangian Models
NASA Astrophysics Data System (ADS)
Lewis, J. M.
2014-12-01
In 1913, G. I. Taylor introduced us to a Lagrangian view of sea fog formation. He conducted his study off the coast of Newfoundland in the aftermath of the Titanic disaster. We briefly review Taylor's classic work and then apply these same principles to a case of sea fog formation and dissipation off the coast of California. The resources used in this study consist of: 1) land-based surface and upper-air observations, 2) NDBC (National Data Buoy Center) observations from moored buoys equipped to measure dew point temperature as well as the standard surface observations at sea (wind, sea surface temperature, pressure, and air temperature), 3) satellite observations of cloud, and 4) a one-dimensional (vertically directed) boundary layer model that tracks with the surface air motion and makes use of sophisticated turbulence-radiation parameterizations. Results of the investigation indicate that delicate interplay and interaction between the radiation and turbulence processes makes accurate forecasts of sea fog onset unlikely in the near future. This pessimistic attitude stems from inadequacy of the existing network of observations and uncertainties in modeling dynamical processes within the boundary layer.
NASA Astrophysics Data System (ADS)
K R, Sreenivas; Mohammad, Rafiuddin
2016-11-01
Predicting the fog-onset, its growth and dissipation helps in managing airports and other modes of transport. After sunset, occurrence of fog requires moist air, low wind and clear-sky conditions. Under these circumstances radiative heat transfer plays a vital role in the NBL. Locally, initiation of fog happens when the air temperature falls below the dew-point. Thus, to predict the onset of fog at a given location, one has to compute evolution of vertical temperature profile. Earlier,our group has shown that the presence of aerosols and vertical variation in their number density determines the radiative-cooling and hence development of vertical temperature profile. Aerosols, through radiation in the window-band, provides an efficient path for air layers to lose heat to the cold, upper atmosphere. This process creates cooler air layer between warmer ground and upper air layers and resulting temperature profile facilitate the initiation of fog. Our results clearly indicates that accounting for the presence of aerosols and their radiative-transfer is important in modeling micro-meteorological process of fog formation and its evolution. DST, Govt. INDIA.
Aerosol Attenuation in the 2-4 Micrometer Region
1975-03-01
Company Model 911ir dew point hydrometer. The lithium chloride sensors will be placed on the roof where the aerosol is sampled and at the entrance...Extinction Measurement il External View of 400 Meter White Cell 13 Primary Aerosol and Gas Handlinfe Systems 14 Calibration for Extinction...Massacusetts. Aerosol-laden air will be drawn into the experimental apparatus from a point 10 ft above the roof of the building. A continuoush
Recovery of Waste Heat from Propellant Forced-Air Dry House
1978-12-01
function of bulk air side film heat transfer coefficient and diffusivity 66 15. Dry house waste heat recovery system instrumentation 67 16. Sample data...inlet condition by, maintaining the exhaust temperature above the NG dew point. The set point is adjustable to accommodate various propel- lant and...system. In dry cycle operation, an overall energy recovery effectiveness of about 40% was measured for winter operation when the exhaust temperature
The importance of dew in watershed-management research
James W. Hornbeck
1964-01-01
Many studies, using various methods, have been made of dew deposition to determine its importance as a source of moisture. For example, Duvdevani (1947) used an optical method in which dew collected on a wooden block was compared with a set of standardized photographs of dew. Potvin (1949) exposed diamond-shaped glass plates at 45º to ground level, so that...
1979-05-08
Prediction. Scaling. Fan Design. 29AOSY14ACY (Cettm.. a P#`04 rv1s. *It UO004N 01- dew 16001 bYstI 610 01c Nh A 12-inch-diameter centrifugal fan impeller...Performance, 3500 RPM84............ 53 Inlet Bellmouth Velocity Survey , Oper Point A, Config 3. 54 Inlet Bellmouth Velocity Survey, Oper Point B...Config 3. 8& 55 Inlet Bellmouth Velocity Survey, Oper Point C, Config 3. ss So Volute Exit Plane Press. Measurement Locations, Config 3 89 57 Volute Exit
The use of DMA to characterize the aging of asphalt binders : tech summary.
DOT National Transportation Integrated Search
2010-06-01
Most of U.S. southeastern states experience both hot and wet summer weather. Extremely high relative humidity and a : low dew point maintain a continuous fi lm of water on Gulf Coast roads during the night and early morning hours. Should : the labora...
40 CFR 90.327 - Sampling system requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...
40 CFR 90.327 - Sampling system requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...
40 CFR 90.327 - Sampling system requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...
77 FR 15813 - Preoperational Testing of Instrument and Control Air Systems
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-16
... seismic requirement, ICAS air-dryer testing to meet dew point design requirements, ICAS accumulator check... ensure consideration only for comments received on or before this date. Although a time limit is given... improvements in all published guides are encouraged at any time. ADDRESSES: You may access information and...
Simple Techniques for Microclimate Measurement.
ERIC Educational Resources Information Center
Unwin, D. M.
1978-01-01
Describes simple ways of measuring the very local climate near the ground, and explains what these measurements mean. Equipment included a solar radiometer, a dew point instrument, and a thermocouple psychrometer. Examples are given of field measurements taken with some of the equipment and the results and their interpretation are discussed.…
Liquid oil production from shale gas condensate reservoirs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, James J.
A process of producing liquid oil from shale gas condensate reservoirs and, more particularly, to increase liquid oil production by huff-n-puff in shale gas condensate reservoirs. The process includes performing a huff-n-puff gas injection mode and flowing the bottom-hole pressure lower than the dew point pressure.
NASA Astrophysics Data System (ADS)
Kidron, Giora J.
2010-11-01
Affected by the interrelationships between the air mass and the substrate properties, dew measurements entail numerous difficulties. Inattentiveness to the complexities involved may result in inconsistent and consequently unreliable data and thus in misleading conclusions. This is especially important in dew deserts such as the Negev where dew may be regarded as an important water source. In an attempt to highlight some of the factors that may affect dew condensation, an experimental approach was adapted during which dew condensation at different surfaces (smooth and ragged Plexiglas, bright limestone and dark flint cobbles), at various size substrata with identical axes (of 2.5, 5, 10, 20, 30 and 40 cm) or different size axes (of 10 × 20, 10 × 30 and 10 × 40 cm), and substrata at different heights and settings was measured. Some of the settings explored were also sheltered by a shrub, a cave, an 80-cm-tall cliff and neighboring cobbles. No significant differences were found in the dew amounts condensing on the limestone and the flint cobbles. Smooth Plexiglas surfaces yielded significantly higher amounts than a ragged Plexiglas surface. As for the substratum height and size, the dew amounts increased with height (from 0.7 to 10.0 cm) and size (from 2.5 × 2.5 cm to 40 × 40 cm). However, an increase in the long axis (a-axis) to 20, 30 and 40 cm while leaving the b-axis constant (at 10 cm) resulted in only a slight increase in the dew amounts in comparison to a 10 × 10 cm substratum. While confined to non-sheltered habitats, dew at partially sheltered habitats (such as the margin of a shrub or a cave, the vicinity of a cliff and on 7-cm-high cobble surrounded by 15-cm-high cobbles) was significantly lower than at the exposed habitats. The differences in dew amounts coincided with minute differences in the surface temperatures, explained as resulting from differences in the outgoing nocturnal longwave radiational cooling. The findings may shed light on the dew regime of lithobionts at different microhabitats and upon inconsistent values reported in the literature.
NASA Astrophysics Data System (ADS)
Knievel, Jason Clark
The author examines a mesoscale convective system (MCS) and the mesoscale convective vortex (MCV) it generated. The MCS, which comprised a leading convective line and trailing stratiform region, traversed Kansas and Oklahoma on 1 August 1996, passing through the NOAA Wind Profiler Network, as well as four sites from which soundings were being taken every three hours during a field project. The unusually rich data set permitted study of the MCS and MCV over nine hours on scales between those of operational rawinsondes and Doppler radars. The author used a spatial bandpass filter to divide observed wind into synoptic and mesoscale components. The environment-relative, mesoscale wind contained an up- and downdraft and divergent outflows in the lower and upper troposphere. The mesoscale wind was asymmetric about the MCS, consistent with studies of gravity waves generated by heating typical of that in many MCSs. According to a scale-discriminating vorticity budget, both the synoptic and mesoscale winds contributed to the prominent resolved sources of vorticity in the MCV: tilting and convergence. Unresolved sources were also large. The author speculates that an abrupt change in the main source of vorticity in an MCV may appear as an abrupt change in its altitude of maximum vorticity. Distributions of temperature and humidity in the MCS were consistent with its mesoscale circulations. In the terminus of the mesoscale downdraft, advection of drier, potentially warmer air exceeded humidifying and cooling from rain, so profiles of temperature and dew point exhibit onion and double-onion patterns. The mesoscale updraft was approximately saturated with a moist adiabatic lapse rate. Mesoscale drafts and convective drafts vertically mixed the troposphere, partially homogenizing equivalent potential temperature. The MCV contained a column of high potential vorticity in the middle troposphere, with a cold core below the freezing level and a warm core above---a pattern characteristic of profiles of heating by stratiform regions. The cold core was 2 km too shallow to be in pure gradient balance with wind in the MCV. On-going forcing during the observed lifetime of the MCV may have prevented it from achieving balance, even if that was its tendency.
Yang, Xuejun; Zhang, Wenhao; Dong, Ming; Boubriak, Ivan; Huang, Zhenying
2011-01-01
Despite proposed ecological importance of mucilage in seed dispersal, germination and seedling establishment, little is known about the role of mucilage in seed pre-germination processes. Here we investigated the role of mucilage in assisting achene cells to repair DNA damage during dew deposition in the desert. Artemisia sphaerocephala achenes were first treated γ-irradiation to induce DNA damage, and then they were repaired in situ in the desert dew. Dew deposition duration can be as long as 421 min in early mornings. Intact achenes absorbed more water than demucilaged achenes during dew deposition and also carried water for longer time following sunrise. After 4-d dew treatment, DNA damage of irradiated intact and demucilaged achenes was reduced to 24.38% and 46.84%, respectively. The irradiated intact achenes exhibited much higher DNA repair ratio than irradiated demucilaged achenes. Irradiated intact achenes showed an improved germination and decreased nonviable achenes after dew treatment, and significant differences in viability between the two types of achenes were detected after 1020 min of dew treatment. Achene mucilage presumably plays an ecologically important role in the life cycle of A. sphaerocephala by aiding DNA repair of achene cells in genomic-stressful habitats. PMID:21912689
Estimation of dew yield from radiative condensers by means of an energy balance model
NASA Astrophysics Data System (ADS)
Maestre-Valero, J. F.; Ragab, R.; Martínez-Alvarez, V.; Baille, A.
2012-08-01
SummaryThis paper presents an energy balance modelling approach to predict the nightly water yield and the surface temperature (Tf) of two passive radiative dew condensers (RDCs) tilted 30° from horizontal. One was fitted with a white hydrophilic polyethylene foil recommended for dew harvest and the other with a black polyethylene foil widely used in horticulture. The model was validated in south-eastern Spain by comparing the simulation outputs with field measurements of Tf and dew yield. The results indicate that the model is robust and accurate in reproducing the behaviour of the two RDCs, especially in what refers to Tf, whose estimates were very close to the observations. The results were somewhat less precise for dew yield, with a larger scatter around the 1:1 relationship. A sensitivity analysis showed that the simulated dew yield was highly sensitive to changes in relative humidity and downward longwave radiation. The proposed approach provides a useful tool to water managers for quantifying the amount of dew that could be harvested as a valuable water resource in arid, semiarid and water stressed regions.
NASA Technical Reports Server (NTRS)
Bauman, William H., III
2010-01-01
The 12-km resolution North American Mesoscale (NAM) model (MesoNAM) is used by the 45th Weather Squadron (45 WS) Launch Weather Officers at Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to support space launch weather operations. The 45 WS tasked the Applied Meteorology Unit to conduct an objective statistics-based analysis of MesoNAM output compared to wind tower mesonet observations and then develop a an operational tool to display the results. The National Centers for Environmental Prediction began running the current version of the MesoNAM in mid-August 2006. The period of record for the dataset was 1 September 2006 - 31 January 2010. The AMU evaluated MesoNAM hourly forecasts from 0 to 84 hours based on model initialization times of 00, 06, 12 and 18 UTC. The MesoNAM forecast winds, temperature and dew point were compared to the observed values of these parameters from the sensors in the KSC/CCAFS wind tower network. The data sets were stratified by model initialization time, month and onshore/offshore flow for each wind tower. Statistics computed included bias (mean difference), standard deviation of the bias, root mean square error (RMSE) and a hypothesis test for bias = O. Twelve wind towers located in close proximity to key launch complexes were used for the statistical analysis with the sensors on the towers positioned at varying heights to include 6 ft, 30 ft, 54 ft, 60 ft, 90 ft, 162 ft, 204 ft and 230 ft depending on the launch vehicle and associated weather launch commit criteria being evaluated. These twelve wind towers support activities for the Space Shuttle (launch and landing), Delta IV, Atlas V and Falcon 9 launch vehicles. For all twelve towers, the results indicate a diurnal signal in the bias of temperature (T) and weaker but discernable diurnal signal in the bias of dewpoint temperature (T(sub d)) in the MesoNAM forecasts. Also, the standard deviation of the bias and RMSE of T, T(sub d), wind speed and wind direction indicated the model error increased with the forecast period all four parameters. The hypothesis testing uses statistics to determine the probability that a given hypothesis is true. The goal of using the hypothesis test was to determine if the model bias of any of the parameters assessed throughout the model forecast period was statistically zero. For th is dataset, if this test produced a value >= -1 .96 or <= 1.96 for a data point, then the bias at that point was effectively zero and the model forecast for that point was considered to have no error. A graphical user interface (GUI) was developed so the 45 WS would have an operational tool at their disposal that would be easy to navigate among the multiple stratifications of information to include tower locations, month, model initialization times, sensor heights and onshore/offshore flow. The AMU developed the GUI using HyperText Markup Language (HTML) so the tool could be used in most popular web browsers with computers running different operating systems such as Microsoft Windows and Linux.
The New Lunar Meteorite DEW 12007
NASA Astrophysics Data System (ADS)
Collareta, A.; D'Orazio, M.; Gemelli, M.; Pack, A.; Folco, L.
2014-09-01
The new lunar meteorite DEW 12007 was found in Antarctica in January 2013 by PNRA. DEW 12007 has been classified as a regolithic breccia of mingled composition. In our abstract we present its first-order geochemical and petrographic features.
Rahim, M; Kazi, B M; Bile, K M; Munir, M; Khan, A R
2010-01-01
The disease early warning system (DEWS) was introduced in the immediate aftermath of the 2005 earthquake in Pakistan, with the objective to undertake prompt investigation and mitigation of disease outbreaks. The DEWS network was replicated successfully during subsequent flood and earthquake disasters as well as during the 2008-09 internally displaced persons' crisis. DEWS-generated alerts, prompt investigations and timely responses had an effective contribution to the control of epidemics. Through DEWS, 1360 reported alerts during 2005-09 averted the risk of disease outbreaks through pre-emptive necessary measures, while the 187 confirmed outbreaks were effectively controlled. In the aftermath of the disasters, DEWS technology also facilitated the development of a disease-surveillance system that became an integral part of the district health system. This study aims to report the DEWS success and substantiate its lead role as a priority emergency health response intervention.
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2010 CFR
2010-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2014 CFR
2014-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2011 CFR
2011-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2012 CFR
2012-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR Appendix A to Subpart D of... - Tables
Code of Federal Regulations, 2013 CFR
2013-07-01
...-test and post-test values) kPa Pv Saturation pressure at dew point temperature kPa Ra Relative humidity...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment... Percent torque related to maximum torque for the test mode % mass Pollutant mass flow g/h nd, i Engine...
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...
40 CFR 91.327 - Sampling system requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...
Dew Point Evaporative Comfort Cooling
2013-07-01
efficiency ratio kBtu kilo British thermal unit kW kilowatt kWh kilowatt-hour M-Cycle Maisotsenko Cycle MCDB mean coincident dry bulb mi2 square...the foothills of the Rocky Mountains. The base covers more than 8.7 square miles ( mi2 ) and includes more than 11 million ft2 of building area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Confer, L.; Kramer, K.L.
A condensing type heat exchanger operating at Henkel Corporation's plant in Kankakee, IL, has enabled the plant to save $400,000 in energy costs within the first 22 months of operation, recouping the initial capital investment for the unit within that time frame. The heat exchanger enables the plant to accomplish what historically was considered taboo - to cool boiler stack gas down to 130/sup 0/F, below the dew point, and thus recover both sensible and latent heat from the gas. Traditionally, moisture could not be squeezed out of stack gas below the recommended temperature of 250/sup 0/F because the stackmore » gas close to the heat exchanger tubes would approach the dew point, condense and attack metal surfaces. The condensing type heat exchanger can withstand corrosive conditions, however, because all wetted surfaces on the flue side of the shell and copper-nickel tube design are protected with an extruded Teflon fluorocarbon resin covering (not coating). The waste heat recovery system was installed over a two-month period in 1985. Performance has been above expectations with greater energy savings than originally projected. The amount of operator attention required is minimal.« less
NASA Astrophysics Data System (ADS)
Chang, Song-Lin
There are only a few solid state humidity sensors available today. Most of those sensors use a porous oxide material as a principal part of the device. The devices work on the basis of a change in resistance as the moisture in the air varies. In this experiment, two solid state humidity sensors have been developed for use under practical conditions. One is a Polymer Oxide Semiconductor device with a POLYOX film that absorbs the moisture from the air. The amount of water dipoles absorbed by the polymer is a function of relative humidity. This sensor can measure relative humidity from 20% to 90%. The other is a Dew Point sensor. The sensor is in contact with the upper surface of a miniature Peltier cooler. Water molecules deposited on the sensor surface cause the electrical current through the sensor to increase. The operator adjusts the temperature of the Peltier cooler until a saturated current through the sensor is reached. About one min. is required to measure low relative humidities. The Dew Point sensor can measure a range of relative humidities of 30% to 80%.
Propagation of sound through the Earth's atmosphere
NASA Technical Reports Server (NTRS)
Meredith, R. W.; Becher, J.
1983-01-01
The data collected at a pressure of one atmosphere for the different temperatures and relative humidities of the air-water vapor mixtures is summarized. The dew point hygrometer used in these measurements did not give reliable results for dew points much above the ambient room temperature. For this reason measurements were not attempted at the higher temperatures and humidities. Viscous wall losses in the resonant tube at 0 C so dominate the molecular relaxation of nitrogen, in the air-water vapor mixture, that reliable data could not be obtained using the free decay method in a resonant tube at one atmosphere. In an effort to obtain viable data at these temperatures, measurements were performed at a pressure of 10 atmospheres. Since the molecular relaxation peak is proportional to the pressure and the viscous losses are proportional to the inverse square root of the pressure the peak height should be measurable at the higher pressure. The tradeoff here is that at 10 atmospheres; the highest relative humidity attainable is 10 percent. The data collected at 10 atmospheres is also summarized.
NASA Astrophysics Data System (ADS)
Kotzen, Benz
2014-05-01
This paper focuses on the potential of dew to provide water to plants and potentially to people as well in remote and difficult to reach areas where rainfall and underground water cannot be harvested. The combat of desertification and the restoration of degraded and desertified dry and arid lands has never been more urgent. A key practical component of this strategy is the restoration of habitat with planting. But for habitat and planting to survive there needs to be an adequate supply of water. In most cases providing water to the plant's roots is vital. In some areas where habitats have been destroyed, sufficient water is immediately available, for example through seasonal rainfall, or it can be harvested to concentrate adequate supplies of water to the roots. However, in arid and hyper arid areas, as well as in some dryland areas, a consistent and adequate supply of water cannot be provided by any conventional proven method. Thus, as the need to combat desertification and to restore desertified dry and arid land increases, so the need to find novel methods of establishing and maintaining planting and thus habitat increases. In more traditional land management scenarios this can be achieved through manipulating landform on a micro and macro scale, for example, by creating catchments, thereby collecting precipitation and directing it to the plants. Where this cannot be done, other means of water supply are usually required. Bainbridge (2007) and others have shown that supplying water to plants is possible through a number of traditional methods, for example, using clay pots. But most of these techniques require an introduced source of water, for example, obtained through water harvesting methods or by delivering water to site in tanks and by water bowser. This can work but requires continuous manpower. It is expensive and can be physically prohibitive in areas where access is difficult and/or remote. The concept of using dew to supply water in drylands is not new and numerous studies have been undertaken to investigate past so-called dew collectors and to research the possibilities of using new ones. Most of the historical dew collectors have been disputed as dew collection devices. (Beysens et al 2006, Beysens et al in Kogan and Trahtman 2006, Graf et al 2008.) However, contemporary dew collection has proven possible in those areas that have dew fall. It is generally agreed by researchers, such as Sharan and Beysens in 2007 and Jacobs et al in 2008 after Monteith (1957) that the theoretical maximum dew yield is in the order of 0.8 l/m2/day. Although the exact maximum has never been defined the amounts can yet be significant. However, In most cases the investigations of dew supply in areas where dew is known to precipitate has been undertaken with inclined roof like planar surfaces. However, erecting these planes in remote areas and within difficult terrain makes this kind of collector impractical. Additionally such planar surfaces demand space on the ground which then diminishes the areas of restoration and large collectors require additional plumbing to distribute water to the plants themselves. Thus in order to better supply dew to plants other forms are required. This paper discusses the various ideas and concepts that have been developed for dew collection that have emerged on the market and the novel ideas that have been initiated by the author. The research undertaken investigates biomimetic forms which emulate plant forms such as various cacti and succulents investigating their ability to increase surface area as well as releasing heat like a radiator. Additionally other spiky, needle like forms are investigated as well as animal forms, such as the surface of the Stenocara gracilipes Namibian beetle which collects fog. The research initiated a new strategy for dew collection dividing dew collectors into two types: 1) Passive dew collectors, where nightly collection and delivery is achieved without people, and 2) Semi-passive dew collectors, which require people to collect the dew after it has formed on the dew collector. Bibliography Bainbridge D.A., 2007, 'A Guide for Desert and Dryland Restoration', Island Press. Beysens, D., Milimouk I., Nikolayev, V. S., Berkowicz, S., Muselli, M., Heusinkveld, B., and Jacobs, A. F. G., 2006, 'Comment on "The moisture from the air as water resource in arid region: Hopes, doubt and facts'' by Kogan and Trahtman', Journal of Arid Environments 67 (2006) 343-352. Beysens, D., Muselli, M., Ohayone, C., Berkowicz, S. M., Soyeux, E., Mileta, M., Ortega, P., 2006, 'Application of passive radiative cooling for dew condensation', Energy 31 (2006) 2303-2315. Jacobs, A. F. G., Heusinkveld, B. G. and Berkowicz, S. M., 2008, 'Passive dew collection in a grassland area, The Netherlands', Atmospheric Research 87 (2008) 377-385. Monteith, J.L., 1957. 'Dew', Quarterly Journal of Royal Meteorological Society 83, 322-341. Sharan, G., Beysens, D., and Milimouk-Melnytchouk, I., 2007, 'A study of dew water yields on Galvanized iron roofs in Kothara (North-West India)', Journal of Arid Environments 69 (2007) 259-269.
NASA Astrophysics Data System (ADS)
Flonard, Michaela; Lo, Esther; Levetin, Estelle
2018-02-01
In the Tulsa area, the Cupressaceae is largely represented by eastern red cedar ( Juniperus virginiana L.). The encroachment of this species into the grasslands of Oklahoma has been well documented, and it is believed this trend will continue. The pollen is known to be allergenic and is a major component of the Tulsa atmosphere in February and March. This study examined airborne Cupressaceae pollen data from 1987 to 2016 to determine long-term trends, pollen seasonal variability, and influence of meteorological variables on airborne pollen concentrations. Pollen was collected through means of a Burkard sampler and analyzed with microscopy. Daily pollen concentrations and yearly pollen metrics showed a high degree of variability. In addition, there were significant increases over time in the seasonal pollen index and in peak concentrations. These increases parallel the increasing population of J. virginiana in the region. Pollen data were split into pre- and post-peak categories for statistical analyses, which revealed significant differences in correlations of the two datasets when analyzed with meteorological conditions. While temperature and dew point, among others were significant in both datasets, other factors, like relative humidity, were significant only in one dataset. Analyses using wind direction showed that southerly and southwestern winds contributed to increased pollen concentrations. This study confirms that J. virginiana pollen has become an increasing risk for individuals sensitive to this pollen and emphasizes the need for long-term aerobiological monitoring in other areas.
Improvement of fog predictability in a coupled system of PAFOG and WRF
NASA Astrophysics Data System (ADS)
Kim, Wonheung; Yum, Seong Soo; Kim, Chang Ki
2017-04-01
Fog is difficult to predict because of the multi-scale nature of its formation mechanism: not only the synoptic conditions but also the local meteorological conditions crucially influence fog formation. Coarse vertical resolution and parameterization errors in fog prediction models are also critical reasons for low predictability. In this study, we use a coupled model system of a 3D mesoscale model (WRF) and a single column model with a fine vertical resolution (PAFOG, PArameterized FOG) to simulate fogs formed over the southern coastal region of the Korean Peninsula, where National Center for Intensive Observation of Severe Weather (NCIO) is located. NCIO is unique in that it has a 300 m meteorological tower built at the location to measure basic meteorological variables (temperature, dew point temperature and winds) at eleven different altitudes, and comprehensive atmospheric physics measurements are made with the various remote sensing instruments such as visibility meter, cloud radar, wind profiler, microwave radiometer, and ceilometer. These measurement data are used as input data to the model system and for evaluating the results. Particularly the data for initial and external forcings, which are tightly connected to the predictability of coupled model system, are derived from the tower measurement. This study aims at finding out the most important factors that influence fog predictability of the coupled system for NCIO. Nudging of meteorological tower data and soil moisture variability are found to be critically influencing fog predictability. Detailed results will be discussed at the conference.
The Nature and Variability of Ensemble Sensitivity Fields that Diagnose Severe Convection
NASA Astrophysics Data System (ADS)
Ancell, B. C.
2017-12-01
Ensemble sensitivity analysis (ESA) is a statistical technique that uses information from an ensemble of forecasts to reveal relationships between chosen forecast metrics and the larger atmospheric state at various forecast times. A number of studies have employed ESA from the perspectives of dynamical interpretation, observation targeting, and ensemble subsetting toward improved probabilistic prediction of high-impact events, mostly at synoptic scales. We tested ESA using convective forecast metrics at the 2016 HWT Spring Forecast Experiment to understand the utility of convective ensemble sensitivity fields in improving forecasts of severe convection and its individual hazards. The main purpose of this evaluation was to understand the temporal coherence and general characteristics of convective sensitivity fields toward future use in improving ensemble predictability within an operational framework.The magnitude and coverage of simulated reflectivity, updraft helicity, and surface wind speed were used as response functions, and the sensitivity of these functions to winds, temperatures, geopotential heights, and dew points at different atmospheric levels and at different forecast times were evaluated on a daily basis throughout the HWT Spring Forecast experiment. These sensitivities were calculated within the Texas Tech real-time ensemble system, which possesses 42 members that run twice daily to 48-hr forecast time. Here we summarize both the findings regarding the nature of the sensitivity fields and the evaluation of the participants that reflects their opinions of the utility of operational ESA. The future direction of ESA for operational use will also be discussed.
NASA Astrophysics Data System (ADS)
Garen, D. C.; Kahl, A.; Marks, D. G.; Winstral, A. H.
2012-12-01
In mountainous catchments, it is well known that meteorological inputs, such as precipitation, air temperature, humidity, etc. vary greatly with elevation, spatial location, and time. Understanding and monitoring catchment inputs is necessary in characterizing and predicting hydrologic response to these inputs. This is true all of the time, but it is the most dramatically critical during large storms, when the input to the stream system due to rain and snowmelt creates the potential for flooding. Besides such crisis events, however, proper estimation of catchment inputs and their spatial distribution is also needed in more prosaic but no less important water and related resource management activities. The first objective of this study is to apply a geostatistical spatial interpolation technique (elevationally detrended kriging) to precipitation and dew point temperature on an hourly basis and explore its characteristics, accuracy, and other issues. The second objective is to use these spatial fields to determine precipitation phase (rain or snow) during a large, dynamic winter storm. The catchment studied is the data-rich Reynolds Creek Experimental Watershed near Boise, Idaho. As part of this analysis, precipitation-elevation lapse rates are examined for spatial and temporal consistency. A clear dependence of lapse rate on precipitation amount exists. Certain stations, however, are outliers from these relationships, showing that significant local effects can be present and raising the question of whether such stations should be used for spatial interpolation. Experiments with selecting subsets of stations demonstrate the importance of elevation range and spatial placement on the interpolated fields. Hourly spatial fields of precipitation and dew point temperature are used to distinguish precipitation phase during a large rain-on-snow storm in December 2005. This application demonstrates the feasibility of producing hourly spatial fields and the importance of doing so to support an accurate determination of precipitation phase for assessing catchment hydrologic response to the storm.
USDA-ARS?s Scientific Manuscript database
Lumbricus terrestris L. (the dew worm) forages, mates and migrates on the soil surface during the night. Its distribution covers a broad latitudinal gradient and variation in day length conditions. Since soil-surface activity is crucial for the survival and reproduction of dew worms, it is conceivab...
A Multilayer Dataset of SSM/I-Derived Global Ocean Surface Turbulent Fluxes
NASA Technical Reports Server (NTRS)
Chou, Shu-Hsien; Shie, Chung-Lin; Atlas, Robert M.; Ardizzone, Joe; Nelkin, Eric; Einaud, Franco (Technical Monitor)
2001-01-01
A dataset including daily- and monthly-mean turbulent fluxes (momentum, latent heat, and sensible heat) and some relevant parameters over global oceans, derived from the Special Sensor Microwave/Imager (SSM/I) data, for the period July 1987-December 1994 and the 1988-94 annual and monthly-mean climatologies of the same variables is created. It has a spatial resolution of 2.0deg x 2.5deg latitude-longitude. The retrieved surface air humidity is found to be generally accurate as compared to the collocated radiosonde observations over global oceans. The retrieved wind stress and latent heat flux show useful accuracy as verified against research quality measurements of ship and buoy in the western equatorial Pacific. The 1988-94 seasonal-mean wind stress and latent heat flux show reasonable patterns related to seasonal variations of the atmospheric general circulation. The patterns of 1990-93 annual-mean turbulent fluxes and input variables are generally in good agreement with one of the best global analyzed flux datasets that based on COADS (comprehensive ocean-atmosphere data set) with corrections on wind speeds and covered the same period. The retrieved wind speed is generally within +/-1 m/s of the COADS-based, but is stronger by approx. 1-2 m/s in the northern extratropical oceans. The discrepancy is suggested to be mainly due to higher COADS-modified wind speeds resulting from underestimation of anemometer heights. Compared to the COADS-based, the retrieved latent heat flux and sea-air humidity difference are generally larger with significant differences in the trade wind zones and the ocean south of 40degS (up to approx. 40-60 W/sq m and approx. 1-1.5 g/kg). The discrepancy is believed to be mainly caused by higher COADS-based surface air humidity arising from the overestimation of dew point temperatures and from the extrapolation of observed high humidity southward into data-void regions south of 40degS. The retrieved sensible heat flux is generally within +/-5 W/sq m of UWM/COADS, except for some areas in the extratropical oceans, where the differences in wind speed have large impact on the difference in sensible heat flux. The dataset of SSM/I-derived turbulent fluxes is useful for climate studies, forcing of ocean models, and validation of coupled ocean-atmosphere global models.
Site Specific Probable Maximum Precipitation Estimates and Professional Judgement
NASA Astrophysics Data System (ADS)
Hayes, B. D.; Kao, S. C.; Kanney, J. F.; Quinlan, K. R.; DeNeale, S. T.
2015-12-01
State and federal regulatory authorities currently rely upon the US National Weather Service Hydrometeorological Reports (HMRs) to determine probable maximum precipitation (PMP) estimates (i.e., rainfall depths and durations) for estimating flooding hazards for relatively broad regions in the US. PMP estimates for the contributing watersheds upstream of vulnerable facilities are used to estimate riverine flooding hazards while site-specific estimates for small water sheds are appropriate for individual facilities such as nuclear power plants. The HMRs are often criticized due to their limitations on basin size, questionable applicability in regions affected by orographic effects, their lack of consist methods, and generally by their age. HMR-51 for generalized PMP estimates for the United States east of the 105th meridian, was published in 1978 and is sometimes perceived as overly conservative. The US Nuclear Regulatory Commission (NRC), is currently reviewing several flood hazard evaluation reports that rely on site specific PMP estimates that have been commercially developed. As such, NRC has recently investigated key areas of expert judgement via a generic audit and one in-depth site specific review as they relate to identifying and quantifying actual and potential storm moisture sources, determining storm transposition limits, and adjusting available moisture during storm transposition. Though much of the approach reviewed was considered a logical extension of HMRs, two key points of expert judgement stood out for further in-depth review. The first relates primarily to small storms and the use of a heuristic for storm representative dew point adjustment developed for the Electric Power Research Institute by North American Weather Consultants in 1993 in order to harmonize historic storms for which only 12 hour dew point data was available with more recent storms in a single database. The second issue relates to the use of climatological averages for spatially interpolating 100-year dew point values rather than a more gauge-based approach. Site specific reviews demonstrated that both issues had potential for lowering the PMP estimate significantly by affecting the in-place and transposed moisture maximization value and, in turn, the final controlling storm for a given basin size and PMP estimate.
NASA Astrophysics Data System (ADS)
Hurter, F.; Maier, O.
2013-11-01
We reconstruct atmospheric wet refractivity profiles for the western part of Switzerland with a least-squares collocation approach from data sets of (a) zenith path delays that are a byproduct of the GPS (global positioning system) processing, (b) ground meteorological measurements, (c) wet refractivity profiles from radio occultations whose tangent points lie within the study area, and (d) radiosonde measurements. Wet refractivity is a parameter partly describing the propagation of electromagnetic waves and depends on the atmospheric parameters temperature and water vapour pressure. In addition, we have measurements of a lower V-band microwave radiometer at Payerne. It delivers temperature profiles at high temporal resolution, especially in the range from ground to 3000 m a.g.l., though vertical information content decreases with height. The temperature profiles together with the collocated wet refractivity profiles provide near-continuous dew point temperature or relative humidity profiles at Payerne for the study period from 2009 to 2011. In the validation of the humidity profiles, we adopt a two-step procedure. We first investigate the reconstruction quality of the wet refractivity profiles at the location of Payerne by comparing them to wet refractivity profiles computed from radiosonde profiles available for that location. We also assess the individual contributions of the data sets to the reconstruction quality and demonstrate a clear benefit from the data combination. Secondly, the accuracy of the conversion from wet refractivity to dew point temperature and relative humidity profiles with the radiometer temperature profiles is examined, comparing them also to radiosonde profiles. For the least-squares collocation solution combining GPS and ground meteorological measurements, we achieve the following error figures with respect to the radiosonde reference: maximum median offset of relative refractivity error is -16% and quartiles are 5% to 40% for the lower troposphere. We further added 189 radio occultations that met our requirements. They mostly improved the accuracy in the upper troposphere. Maximum median offsets have decreased from 120% relative error to 44% at 8 km height. Dew point temperature profiles after the conversion with radiometer temperatures compare to radiosonde profiles as to: absolute dew point temperature errors in the lower troposphere have a maximum median offset of -2 K and maximum quartiles of 4.5 K. For relative humidity, we get a maximum mean offset of 7.3%, with standard deviations of 12-20%. The methodology presented allows us to reconstruct humidity profiles at any location where temperature profiles, but no atmospheric humidity measurements other than from GPS are available. Additional data sets of wet refractivity are shown to be easily integrated into the framework and strongly aid the reconstruction. Since the used data sets are all operational and available in near-realtime, we envisage the methodology of this paper to be a tool for nowcasting of clouds and rain and to understand processes in the boundary layer and at its top.
NASA Technical Reports Server (NTRS)
Bauman, William H., III
2010-01-01
The AMU conducted an objective analysis of the MesoNAM forecasts compared to observed values from sensors at specified KSC/CCAFS wind towers by calculating the following statistics to verify the performance of the model: 1) Bias (mean difference), 2) Standard deviation of Bias, 3) Root Mean Square Error (RMSE), and 4) Hypothesis test for Bias = O. The 45 WS LWOs use the MesoNAM to support launch weather operations. However, the actual performance of the model at KSC and CCAFS had not been measured objectively. The analysis compared the MesoNAM forecast winds, temperature and dew point to the observed values from the sensors on wind towers. The data were stratified by tower sensor, month and onshore/offshore wind direction based on the orientation of the coastline to each tower's location. The model's performance statistics were then calculated for each wind tower based on sensor height and model initialization time. The period of record for the data used in this task was based on the operational start of the current MesoNAM in mid-August 2006 and so the task began with the first full month of data, September 2006, through May 2010. The analysis of model performance indicated: a) The accuracy decreased as the forecast valid time from the model initialization increased, b) There was a diurnal signal in T with a cool bias during the late night and a warm bias during the afternoon, c) There was a diurnal signal in Td with a low bias during the afternoon and a high bias during the late night, and d) The model parameters at each vertical level most closely matched the observed parameters at heights closest to those vertical levels. The AMU developed a GUI that consists of a multi-level drop-down menu written in JavaScript embedded within the HTML code. This tool allows the LWO to easily and efficiently navigate among the charts and spreadsheet files containing the model performance statistics. The objective statistics give the LWOs knowledge of the model's strengths and weaknesses and the GUI allows quick access to the data which will result in improved forecasts for operations.
Analysis of the Variability of Poor Visibility Events in North and Central United Arab Emirates
NASA Astrophysics Data System (ADS)
Aldababseh, Amal; Temimi, Marouane
2016-12-01
Good visibility is essential for the safety of ground transportation and aviation sectors. Degradation in visibility can occur during wet or dry conditions and can therefore be a proxy for air pollution and atmospheric conditions. Moreover, visibility indicates the long-term impact on human health and climate and the relationship with local atmospheric pollution. The major factors triggering the degradation of visibility can be inferred by analyzing visibility long-term trends. In the UAE, we expect that the unprecedented growth in urban development and the aviation sector has impacted visibility records. This study is the first attempt to thoroughly investigate temporal and spatial variations in poor visibility measurements in the UAE and at four different visibility observation levels; less than 5000m, 2500m, 1000m and 100m, as well as to analyze the correlation between poor visibility measurements and different meteorological parameters (relative humidity, air temperature, wind direction and speed) under two weather conditions; wet and dry. Results show that eliminating all meteorological conditions (fog, mist, haze, and precipitation and dust) does not change the overall decreasing trend in visibility, this suggests that the changes in the air quality might be responsible for the long-term visibility degradation. The decreasing trends in visibility vary from the different major cities in the UAE. All the meteorological parameters studied are significantly related to visibility, indicating the existence of complex mechanisms (physical and chemical) that affect the visibility in the atmosphere. Visibility is positively correlated to relative humidity and wind direction, however, it is negatively correlated with temperature, wind speed and dew point. This is possibly related to the weather systems in summer and winter. In summer the presence of synoptic systems along with the very high temperature, low pressure, very high humidity, and very high wind speed due to the Shamal often lead to low visibility, whereas in winter the relatively high wind speed suggests more efficient diffusion conditions and dilutes pollutions and dust particulates to low concentration, with lower temperature and limited precipitation favors high visibility.
Baenninger, Philipp B; Voegeli, Susanne; Bachmann, Lucas M; Faes, Livia; Iselin, Katja; Kaufmann, Claude; Thiel, Michael A
2018-04-04
To assess the variability of osmolarity measured by the point-of-care TearLab system in healthy eyes. A systematic review was performed by searching MEDLINE, Scopus, and the Web of Science Databases until November 2016 and checking reference lists of included articles and reviews. The requirements for inclusion were the availability of TearLab results in healthy subjects and a minimum study sample of 20 eyes. Two reviewers assessed articles against the inclusion criteria, extracted relevant data, and examined the methodological quality. We computed the weighted mean osmolarity using the study size as the weighting factor and calculated the rate of subjects with osmolarity values >308 mOsm/L, the Dry Eye Workshop Report 2017 (DEWS) cut-off value for dry eye disease (DED). We repeated the analysis after excluding reports with a possible conflict of interest or missing description of subject selection. Searches retrieved 105 nonduplicate articles, and we included 33 studies investigating 1362 eyes of healthy participants who were asymptomatic and showed no clinical signs of DED. Sixty-three percent were female, and mean age was 37.3 years (range: 21.5-69.0 yr). Weighted mean osmolarity was 298 mOsm/L (95% confidence interval, 282-321 mOsm/L). The result of the subgroup analysis was similar. Overall, 386 of 1362 eyes (28.3%) fulfilled the DEWS's definition of DED (>308 mOsm/L). There is a high variability of osmolarity measurements with the TearLab system. A substantial number of healthy subjects fulfill the DEWS's definition of DED. We propose interpreting the TearLab osmolarity results cautiously and in the context of other established methods.
Meteorological Techniques (Revision 26 Apr 2006)
2003-06-13
OVV Graph ------------------------------------------------------------------------ 2-11 Figure 2-26 Dissipation of Stratus Using Mixing Ratio and...2-51 Figure 2-70 Bright Band Identification Using the WSR-88D. ------------------------------------------ 2-52 Figure 2-71 Example of Visible...R2, and R3 relative humidity values and cloud amounts ------------------------- 2-7 Table 2-4 Base of convective clouds using surface dew-point
NASA Technical Reports Server (NTRS)
Hamner, Richard M.; Mcguire, Janice K.
1988-01-01
Water content in gas controlled. Portable flow-control system generates nitrogen/water atmosphere having range of dew points and pressures. One use of system provides wet nitrogen for canister of wide-field camera requiring this special atmosphere. Also used to inject trace gases other than water vapor for leak testing of large vessels. Potential applications in photography, hospitals, and calibration laboratories.
USDA-ARS?s Scientific Manuscript database
Thirty one years of spatially distributed air temperature, relative humidity, dew point temperature, precipitation amount, and precipitation phase data are presented for the Reynolds Creek Experimental Watershed. The data are spatially distributed over a 10m Lidar-derived digital elevation model at ...
ERIC Educational Resources Information Center
Kohler, Fred E.
The document describes the use of weather maps and data in teaching introductory college courses in synoptic meteorology. Students examine weather changes at three-hour intervals from data obtained from the "Monthly Summary of Local Climatological Data." Weather variables in the local summary include sky cover, air temperature, dew point, relative…
Gela, Italy, Revised Uniform Summary of Surface Weather Observations (RUSSWO). Parts A-F.
1983-11-03
ADDRESS I2 REPORT DATE USAFETAC/ CBD 3 Nov 83 Air Weather Service (MAC) 13 NUMBER OF PAGES Scott AFB IL 62225 p. _ _ _0 r4 MONITORING AGENCY NAME & ADDRESS...temperature Lombined; tuid again for dry-bulb, wet-bulb, and dew-point tempera- tures separately. Total observations for thc .;e four Items is also
Sweating Like a Pig: Physics or Irony?
ERIC Educational Resources Information Center
Bohren, Craig F.
2016-01-01
In his interesting and informative book "Is That a Fact?," Joe Schwarcz avers that pigs do not sweat and the saying "sweating like a pig" originates in iron smelting. Oblong pieces of hot iron, with a fancied resemblance to a sow with piglets, cool in sand to the dew point of the surrounding air, and hence water condenses on…
Efficacy improvement of a bioherbicidal fungus using a formulation-based approach
USDA-ARS?s Scientific Manuscript database
Greenhouse experiments were conducted to determine the effects of an invert (water - in - oil) emulsion (IE) on dew period duration and dew delay of Colletotrichum coccodes for biocontrol of the problematic weed, eastern black nightshade (Solanum ptycanthum). Dew periods of 4, 8, or 12 h provided ...
Hou, Dibo; Song, Xiaoxuan; Zhang, Guangxin; Zhang, Hongjian; Loaiciga, Hugo
2013-07-01
An event-driven, urban, drinking water quality early warning and control system (DEWS) is proposed to cope with China's urgent need for protecting its urban drinking water. The DEWS has a web service structure and provides users with water quality monitoring functions, water quality early warning functions, and water quality accident decision-making functions. The DEWS functionality is guided by the principles of control theory and risk assessment as applied to the feedback control of urban water supply systems. The DEWS has been deployed in several large Chinese cities and found to perform well insofar as water quality early warning and emergency decision-making is concerned. This paper describes a DEWS for urban water quality protection that has been developed in China.
Transpiration Cooled Throat for Hydrocarbon Rocket Engines
1991-12-01
entering the oxidizer circuit. Maximum dew point requirement was -500F. The purge pressure provided an oxidizer injector cold-flow pressure of 80 psia...energy bal- ance with the core gas is assumed wherein the heat flux to the annular liquid RP-I layer is equal’ 50 042 0 I- C3 I C30 ME1 M1 49 410 CI... gas generator mixture ratio MW molecular weight NASA/L.RC NASA Lewis Research Center NBP normal boiling point Ni chemical symbol for nickel nom
NASA Astrophysics Data System (ADS)
Schneebeli, M.; Wolf, S.; Kunert, N.; Eugster, W.; Mätzler, C.
2012-04-01
During summer and autumn 2007, a 11 GHz microwave radiometer was deployed in an experimental tree plantation in Sardinilla, Panama. With this instrument, the opacity of the tree canopy was derived from incoming brightness temperatures received on the ground. A collocated eddy-covariance flux tower measured water vapor fluxes and meteorological variables above the canopy. It was found that canopy intercepted rain and dew formation modulated the diurnal opacity cycle. With an enhanced canopy opacity model accounting for water deposited on the leaves, we quantified the influence of canopy stored water (i.e. intercepted water and dew) on the opacity. With this technique it was possible to directly monitor high resolution time series of dew formation and rain interception during a period of two weeks. In contrast to through-fall measurements, this new technique allows to determine the amount of intercepted rain more precisely and during day and night since evaporation effects do not hamper the accuracy of the method. We found that during light rainfall up to 60% of the rain amount is intercepted by the canopy whereas during periods of intense rainfall, only 4% were intercepted. On average, about 15% of the rain amount was intercepted during rainfalls of medium intensities. By comparing the interception with the water vapor flux time series it was found that intercepted water is evaporated rapidly after it is deposited on the leaves, which resulted in an enhanced water vapor flux. Our study also provides the first direct measurements and quantifications of the temporal evolution of dew formation and evaporation in a tree canopy on a diurnal base. Dew accumulated during the night and until about 2 h after sunrise, when the water vapor flux began to exceed the dew formation rate. The dew continued to evaporate for another 3.5 h until the surface of the leaves was completely dry. On average, 0.17 mm of dew was formed during the night. Dew evaporation contributed 5% to the total water vapor flux measured above the canopy.
Merle G. Lloyd
1963-01-01
The instrument developed by Intermountain Forest and Range Experiment Station to record duration and amount of dew (fig. 1) consists of an expanded polystyrene block mounted on a balance, a clock-driven drum, and a pen geared from the balance to the drum. Changes in weight of the expanded polystyrene block as dew or rain is deposited are recorded on a chart mounted on...
Microclimate environmental parameters indexed for Sudden Oak death in Georgia and South Carolina
Pauline Spaine; William J. Otrosina; Stanley J. Zarnoch; Sharon V. Lumpkin
2008-01-01
We monitored Ericaceous habitat in Georgia and South Carolina for temperature, dew point and humidity ranges throughout a two year period. Temperature and humidity data were used to characterize their range in Georgia and South Carolina where potential SOD susceptible hosts occur. This data suggests risk for SOD development may be more widespread in southeastern forest...
Dew Point Evaporative Comfort Cooling
2012-11-01
assisting with the installation of the data acquisition system and multiyear performance testing. Fort Carson engineers worked with the project...partners to design and integrate the Coolerado units into five facilities and designed an innovative rain water catchment system for four units at the...Theater. Mountain Energy Partnership provided invaluable assistance with the design and installation of the data acquisition system , as well as data
Avoid the Wet Basement Blues: Construction Methods Guarantee Success
ERIC Educational Resources Information Center
Domermuth, David
2006-01-01
A damp basement can be a nightmare, especially after mildew creates its eye-watering, nose-offending stench. There are two enemies to overcome: damp air condensing on interior walls and ground water penetrating the exterior. One can address condensation by drying or heating the air in a basement to raise it above the dew point. The simple way to…
Air drying of softwood lumber, Fairbanks, Alaska.
George R Sampson; Forrest A. Ruppert
1985-01-01
Air-drying rates for two stacks of 2-inch-thick white spruce were observed in the Fairbanks area during summer 1982. The air-drying rate for the same size lumber was also observed during winter 1982-83. Very little drying occurred during the winter. Drying rates in summer were correlated with average daily temperature and average daily dew point to derive predictive...
Operating manual for the RRL 8 channel data logger
NASA Technical Reports Server (NTRS)
Paluch, E. J.; Shelton, J. D.; Gardner, C. S.
1979-01-01
A data collection device which takes measurements from external sensors at user specified time intervals is described. Three sensor ports are dedicated to temperature, air pressure, and dew point. Five general purpose sensor ports are provided. The user specifies when the measurements are recorded as well as when the information is read or stored in a minicomputer or a paper tape.
Advances in thermal control and performance of the MMT M1 mirror
NASA Astrophysics Data System (ADS)
Gibson, J. D.; Williams, G. G.; Callahan, S.; Comisso, B.; Ortiz, R.; Williams, J. T.
2010-07-01
Strategies for thermal control of the 6.5-meter diameter borosilicate honeycomb primary (M1) mirror at the MMT Observatory have included: 1) direct control of ventilation system chiller setpoints by the telescope operator, 2) semiautomated control of chiller setpoints, using a fixed offset from the ambient temperature, and 3) most recently, an automated temperature controller for conditioned air. Details of this automated controller, including the integration of multiple chillers, heat exchangers, and temperature/dew point sensors, are presented here. Constraints and sanity checks for thermal control are also discussed, including: 1) mirror and hardware safety, 2) aluminum coating preservation, and 3) optimization of M1 thermal conditions for science acquisition by minimizing both air-to-glass temperature differences, which cause mirror seeing, and internal glass temperature gradients, which cause wavefront errors. Consideration is given to special operating conditions, such as high dew and frost points. Precise temperature control of conditioned ventilation air as delivered to the M1 mirror cell is also discussed. The performance of the new automated controller is assessed and compared to previous control strategies. Finally, suggestions are made for further refinement of the M1 mirror thermal control system and related algorithms.
Bearg, D W
1998-09-01
This article summarizes an approach for improving the indoor air quality (IAQ) in a building by providing feedback on the performance of the ventilation system. The delivery of adequate quantities of ventilation to all building occupants is necessary for the achievement of good IAQ. Feedback on the performance includes information on the adequacy of ventilation provided, the effectiveness of the distribution of this air, the adequacy of the duration of operation of the ventilation system, and the identification of leakage into the return plenum, either of outdoor or supply air. Keeping track of ventilation system performance is important not only in terms of maintaining good IAQ, but also making sure that this system continues to perform as intended after changes in building use. Information on the performance of the ventilation system is achieved by means of an automated sampling system that draws air from multiple locations and delivers it to both a carbon dioxide monitor and dew point sensor. The use of single shared sensors facilitates calibration checks as well as helps to guarantee data integrity. This approach to monitoring a building's ventilation system offers the possibility of achieving sustainable performance of this important aspect of good IAQ.
NASA Astrophysics Data System (ADS)
Lobit, P.; López Pérez, L.; Lhomme, J. P.; Gómez Tagle, A.
2017-07-01
This study evaluates the dew point method (Allen et al. 1998) to estimate atmospheric vapor pressure from minimum temperature, and proposes an improved model to estimate it from maximum and minimum temperature. Both methods were evaluated on 786 weather stations in Mexico. The dew point method induced positive bias in dry areas but also negative bias in coastal areas, and its average root mean square error for all evaluated stations was 0.38 kPa. The improved model assumed a bi-linear relation between estimated vapor pressure deficit (difference between saturated vapor pressure at minimum and average temperature) and measured vapor pressure deficit. The parameters of these relations were estimated from historical annual median values of relative humidity. This model removed bias and allowed for a root mean square error of 0.31 kPa. When no historical measurements of relative humidity were available, empirical relations were proposed to estimate it from latitude and altitude, with only a slight degradation on the model accuracy (RMSE = 0.33 kPa, bias = -0.07 kPa). The applicability of the method to other environments is discussed.
Control of membrane permeability in air-stable droplet interface bilayers
Mruetusatorn, Prachya; Polizos, Georgios; Datskos, Panos G.; ...
2015-03-19
Air-stable droplet interface bilayers (airDIBs) on oil-infused surfaces are versatile model membranes for synthetic biology applications, including biosensing of airborne species. However, air-DIBs are subject to evaporation, which can, over time, destabilize them and reduce their useful lifetime compared to traditional DIBs that are fully submerged in oil. Here, we show that lifetimes of air-DIBs can be extended by as much as an order of magnitude by maintaining them at a temperature just above the dew point. We find that raising the temperature from near the dew point (7 C at 38.5 % relative humidity) to room temperature results inmore » loss of water molecules of hydration from the polar head groups of the lipid bilayer membrane due to evaporation in an irreversible process that increases the overall entropy of the system. This dehydration transition affects primarily the bilayer resistance, by increasing ion permeability through the increasingly disordered polar head group region of the bilayer. Temperature and/or relative humidity are conveniently tunable parameters for controlling the stability and composition of air-DIBs membranes, while still allowing for operation in ambient environments.« less
NASA Astrophysics Data System (ADS)
Park, Se Min; Koo, Yang Mo; Shim, Byoung Yul; Lee, Dong Nyung
2017-01-01
In Fe-3%Si-0.3%C steel sheet, a relatively strong <100>//ND texture can evolve in the surface layer through the α→γ→α phase transformation in relatively low vacuum (4 Pa) for an annealing time of 10 min and at a cooling rate of 20 K/s. Oxidation of the steel sheet surface prevents the evolution of the <100>//ND texture. However, vacuum-annealing under a vacuum pressure of 1.3×10-3 Pa causes decarburization of the steel sheet, which suppresses oxidation of the steel sheet surface, and subsequent annealing in wet hydrogen of 363 K in dew points causes a columnar grain structure with the <100>//ND texture. After the two-step-annealing (the vacuum annealing under a vacuum pressure of 1.3×10-3 Pa and subsequent decarburizing annealing in wet hydrogen of 363 K in dew points), the decarburized steel sheet exhibits good soft magnetic properties in NO with 3%Si, W15/50 (core loss at 1.5T and 50 Hz) = 2.47 W/kg and B50 (magnetic flux density at 5000 A/m) = 1.71 T.
Gleiser, R M; Gorla, D E
2007-12-01
Ochlerotatus albifasciatus is a vector of western equine encephalomyelitis in Argentina and a nuisance mosquito affecting beef and dairy production. The objective of this study was to analyze whether environmental proxy data derived from 1 km resolution NOAA-AVHRR images could be useful as a rapid tool for locating areas with higher potential for Oc. albifasciatus activity at a regional scale. Training sites for mosquito abundance categories were 3.3x3.3 km polygons over sampling sites. Abundance was classified into two categories according to a proposed threshold for economic losses. Data of channels 1, 2, 4 and 5 were used to calculate five biophysical variables: normalized differences vegetation index (NDVI), land surface temperature, total precipitable water, dew point and vapour saturation deficit. A discriminant analysis correctly classified 100% of the areas predicted to be above or below the economic threshold of 2500 mosquitoes per night of capture, respectively. Components of the NDVI, the total precipitable water and the dew point temperature contributed most to the function value. The results suggest that environmental data derived from AVHRR-NOAA could be useful for rapidly identifying adequate areas for mosquito development or activity.
The impact of time and field conditions on brown bear (Ursus arctos) faecal DNA amplification
Murphy, M.A.; Kendall, K.C.; Robinson, A.; Waits, L.P.
2007-01-01
To establish longevity of faecal DNA samples under varying summer field conditions, we collected 53 faeces from captive brown bears (Ursus arctos) on a restricted vegetation diet. Each faeces was divided, and one half was placed on a warm, dry field site while the other half was placed on a cool, wet field site on Moscow Mountain, Idaho, USA. Temperature, relative humidity, and dew point data were collected on each site, and faeces were sampled for DNA extraction at <1, 3, 6, 14, 30, 45, and 60 days. Faecal DNA sample viability was assessed by attempting PCR amplification of a mitochondrial DNA (mtDNA) locus (???150 bp) and a nuclear DNA (nDNA) microsatellite locus (180-200 bp). Time in the field, temperature, and dew point impacted mtDNA and nDNA amplification success with the greatest drop in success rates occurring between 1 and 3 days. In addition, genotyping errors significantly increased over time at both field sites. Based on these results, we recommend collecting samples at frequent transect intervals and focusing sampling efforts during drier portions of the year when possible. ?? 2007 Springer Science+Business Media, Inc.
NASA Astrophysics Data System (ADS)
Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel
2013-01-01
As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Lekouch, I.; Kabbachi, B.; Milimouk-Melnytchouk, I.; Muselli, M.; Beysens, D.
2010-07-01
In order to be used as alternative or supplemental sources of water, the physical and physico-chemical characteristics of rain, fog and dew water were investigated at Mirleft in the arid coastal environment of south-west Morocco. A site was instrumented on a terrace with a fog net collector, four 1 m2 inclined (30° ) test dew condenser, together with a weather station providing standard meteorological data. The study was carried out between May 1, 2007 and Avril 30, 2008. Over the one year period were noted 178 dew events (49% yearly occurrence), 31 rain events (8.5 % yearly occurrence) and 7 significant fog events (2 % yearly occurrence). The total quantity of collected water was 48.7 mm (rain), 18.9 mm (dew) and 1.4 mm (fog). Then collecting dew increases almost 40% the water yield although fog contributes to only 3%. A number of physico-chemical and biological parameters were also measured for dew and rain water: pH, electrical conductivity (EC), major anions (HCO3-,Cl-, SO42-,NO3-), major cations (NH4+, Na+, K+, Ca2+, Mg2+). It is found that the mean dew and rain pH are equal to 7.4 and 6.9, respectively and the mean EC are 730 ? S/cm and 316 ? S/cm, respectively, corresponding to large total mineralization. The ratio TA/TC < 1 indicates the alkaline nature of dew and rain water. The analysis of the major ions shows that the concentration of Cl- and Na+ is high compared to that of the other elements. To consider the marine and nonmarine origin of these ions, the fraction of salt coming from sea (SSF) was also calculated. While in dew Cl-, Na+ et Mg2+ are clearly of marine origine, the small SSF value for Ca2+, K+, SO4- et NO3- in dew suggests a considerable contribution of nonmarine origin for these components. In contrast, in rainwater, the values of the No Sea Salt Fraction (NSSF) indicates that only Ca2+ et NO3-are of non marine origin. The dry and transition seasons (spring, summer, fall) correspond to a water more concentrated in elements than during the wet season (winter), in relation to the water yield. The ions concentration agrees with the World Health Organization requirements for potable water. The biological analysis shows harmless vegetal spores and little contamination by animal/human bacteria.
Analytically based photon scatter modeling for a multipinhole cardiac SPECT camera.
Pourmoghaddas, Amir; Wells, R Glenn
2016-11-01
Dedicated cardiac SPECT scanners have improved performance over standard gamma cameras allowing reductions in acquisition times and/or injected activity. One approach to improving performance has been to use pinhole collimators, but this can cause position-dependent variations in attenuation, sensitivity, and spatial resolution. CT attenuation correction (AC) and an accurate system model can compensate for many of these effects; however, scatter correction (SC) remains an outstanding issue. In addition, in cameras using cadmium-zinc-telluride-based detectors, a large portion of unscattered photons is detected with reduced energy (low-energy tail). Consequently, application of energy-based SC approaches in these cameras leads to a higher increase in noise than with standard cameras due to the subtraction of true counts detected in the low-energy tail. Model-based approaches with parallel-hole collimator systems accurately calculate scatter based on the physics of photon interactions in the patient and camera and generate lower-noise estimates of scatter than energy-based SC. In this study, the accuracy of a model-based SC method was assessed using physical phantom studies on the GE-Discovery NM530c and its performance was compared to a dual energy window (DEW)-SC method. The analytical photon distribution (APD) method was used to calculate the distribution of probabilities that emitted photons will scatter in the surrounding scattering medium and be subsequently detected. APD scatter calculations for 99m Tc-SPECT (140 ± 14 keV) were validated with point-source measurements and 15 anthropomorphic cardiac-torso phantom experiments and varying levels of extra-cardiac activity causing scatter inside the heart. The activity inserted into the myocardial compartment of the phantom was first measured using a dose calibrator. CT images were acquired on an Infinia Hawkeye (GE Healthcare) SPECT/CT and coregistered with emission data for AC. For comparison, DEW scatter projections (120 ± 6 keV ) were also extracted from the acquired list-mode SPECT data. Either APD or DEW scatter projections were subtracted from corresponding 140 keV measured projections and then reconstructed with AC (APD-SC and DEW-SC). Quantitative accuracy of the activity measured in the heart for the APD-SC and DEW-SC images was assessed against dose calibrator measurements. The difference between modeled and acquired projections was measured as the root-mean-squared-error (RMSE). APD-modeled projections for a clinical cardiac study were also evaluated. APD-modeled projections showed good agreement with SPECT measurements and had reduced noise compared to DEW scatter estimates. APD-SC reduced mean error in activity measurement compared to DEW-SC in images and the reduction was statistically significant where the scatter fraction (SF) was large (mean SF = 28.5%, T-test p = 0.007). APD-SC reduced measurement uncertainties as well; however, the difference was not found to be statistically significant (F-test p > 0.5). RMSE comparisons showed that elevated levels of scatter did not significantly contribute to a change in RMSE (p > 0.2). Model-based APD scatter estimation is feasible for dedicated cardiac SPECT scanners with pinhole collimators. APD-SC images performed better than DEW-SC images and improved the accuracy of activity measurement in high-scatter scenarios.
Grünbacher, André; Throm, Tanja; Seidel, Constanze; Gutt, Beatrice; Röhrig, Julian; Strunk, Timo; Vincze, Paul; Walheim, Stefan; Schimmel, Thomas; Wenzel, Wolfgang; Fischer, Reinhard
2014-01-01
Hydrophobins are amphiphilic proteins able to self-assemble at water-air interphases and are only found in filamentous fungi. In Aspergillus nidulans two hydrophobins, RodA and DewA, have been characterized, which both localize on the conidiospore surface and contribute to its hydrophobicity. RodA is the constituent protein of very regularly arranged rodlets, 10 nm in diameter. Here we analyzed four more hydrophobins, DewB-E, in A. nidulans and found that all six hydrophobins contribute to the hydrophobic surface of the conidiospores but only deletion of rodA caused loss of the rodlet structure. Analysis of the rodlets in the dewB-E deletion strains with atomic force microscopy revealed that the rodlets appeared less robust. Expression of DewA and DewB driven from the rodA promoter and secreted with the RodA secretion signal in a strain lacking RodA, restored partly the hydrophobicity. DewA and B were able to form rodlets to some extent but never reached the rodlet structure of RodA. The rodlet-lacking rodA-deletion strain opens the possibility to systematically study rodlet formation of other natural or synthetic hydrophobins.
Seidel, Constanze; Gutt, Beatrice; Röhrig, Julian; Strunk, Timo; Vincze, Paul; Walheim, Stefan; Schimmel, Thomas; Wenzel, Wolfgang; Fischer, Reinhard
2014-01-01
Hydrophobins are amphiphilic proteins able to self-assemble at water-air interphases and are only found in filamentous fungi. In Aspergillus nidulans two hydrophobins, RodA and DewA, have been characterized, which both localize on the conidiospore surface and contribute to its hydrophobicity. RodA is the constituent protein of very regularly arranged rodlets, 10 nm in diameter. Here we analyzed four more hydrophobins, DewB-E, in A. nidulans and found that all six hydrophobins contribute to the hydrophobic surface of the conidiospores but only deletion of rodA caused loss of the rodlet structure. Analysis of the rodlets in the dewB-E deletion strains with atomic force microscopy revealed that the rodlets appeared less robust. Expression of DewA and DewB driven from the rodA promoter and secreted with the RodA secretion signal in a strain lacking RodA, restored partly the hydrophobicity. DewA and B were able to form rodlets to some extent but never reached the rodlet structure of RodA. The rodlet-lacking rodA-deletion strain opens the possibility to systematically study rodlet formation of other natural or synthetic hydrophobins. PMID:24722460
Miscellaneous methods for measuring matric or water potential
Scanlon, Bridget R.; Andraski, Brian J.; Bilskie, Jim; Dane, Jacob H.; Topp, G. Clarke
2002-01-01
A variety of techniques to measure matric potential or water potential in the laboratory and in the field are described in this section. The techniques described herein require equilibration of some medium whose matric or water potential can be determined from previous calibration or can be measured directly. Under equilibrium conditions the matric or water potential of the medium is equal to that of the soil. The techniques can be divided into: (i) those that measure matric potential and (ii) those that measure water potential (sum of matric and osmotic potentials). Matric potential is determined when the sensor matrix is in direct contact with the soil, so salts are free to diffuse in or out of the sensor matrix, and the equilibrium measurement therefore reflects matric forces acting on the water. Water potential is determined when the sensor is separated from the soil by a vapor gap, so salts are not free to move in or out of the sensor, and the equilibrium measurement reflects the sum of the matric and osmotic forces acting on the water.Seven different techniques are described in this section. Those that measure matric potential include (i) heat dissipation sensors, (ii) electrical resistance sensors, (iii) frequency domain and time domain sensors, and (iv) electro-optical switches. A method that can be used to measure matric potential or water potential is the (v) filter paper method. Techniques that measure water potential include (vi) the Dew Point Potentiameter (Decagon Devices, Inc., Pullman, WA1) (water activity meter) and (vii) vapor equilibration.The first four techniques are electronically based methods for measuring matric potential. Heat dissipation sensors and electrical resistance sensors infer matric potential from previously determined calibration relations between sensor heat dissipation or electrical resistance and matric potential. Frequency-domain and timedomain matric potential sensors measure water content, which is related to matric potential of the sensor through calibration. Electro-optical switches measure changes in light transmission through thin, nylon filters as they absorb or desorb water in response to changes in matric potential. Heat dissipation sensors and electrical resistance sensors are used primarily in the field to provide information on matric potential. Frequency domain matric potential sensors are new and have not been widely used. Time domain matric potential sensors and electro-optical switches are new and have not been commercialized. For the fifth technique, filter paper is used as the standard matrix. The filter paper technique measures matric potential when the filter paper is in direct contact with soil or water potential when separated from soil by a vapor gap. The Dew Point Potentiameter calculates water potential from the measured dew point and sample temperature. The vapor equilibration technique involves equilibration of soil samples with salt solutions of known osmotic potential. The filter paper, Dew Point Potentiameter, and vapor equilibration techniques are generally used in the laboratory to measure water potential of disturbed field samples or to measure water potential for water retention functions.
Field Comparison between Sling Psychrometer and Meteorological Measuring Set AN/TMQ-22
the ML-224 Sling Psychrometer . From a series of independent tests designed to minimize error it was concluded that the AN/TMQ-22 yielded a more accurate...dew point reading. The average relative humidity error using the sling psychrometer was +9% while the AN/TMQ-22 had a plus or minus 2% error. Even with cautious measurement the sling yielded a +4% error.
NAVFAC Ocean Thermal Energy Conversion (OTEC) Project; OTEC System Design Report
2010-11-16
191 Figure 3-129. Web illustration of a magnetically coupled pump ...............................................192 Figure 3-130...utility air at a suitable water dew point. Two 100% capacity rotary screw compressors, dryer and receiver shall be installed to serve process and...remora centerline, with positive TCG out of the paper and negative TCG into the paper . The CG of the remora in its vertical orientation is
Ethics, Interpretation, and Pedagogy: Martin Buber and the Undergraduate Literature Classroom
ERIC Educational Resources Information Center
Dew, Spencer
2007-01-01
Martin Buber, widely recognized as a philosopher and theologian, frequently lauded as a prophet, said at a celebration of his 80th birthday, "I am no philosopher, prophet, or theologian. I am simply a man who has seen something and who goes to a window and points to what he has seen." In this article, Spencer Dew calls that statement a…
Nocturnal Fanning Suppresses Downy Mildew Epidemics in Sweet Basil
Cohen, Yigal; Ben-Naim, Yariv
2016-01-01
Downy mildew is currently the most serious disease of sweet basil around the world. The oomycete causal agent Peronospora belbahrii requires ≥ 4h free leaf moisture for infection and ≥7.5h of water-saturated atmosphere (relative humidity RH≥95%) at night for sporulation. We show here that continued nocturnal fanning (wind speed of 0.4–1.5 m/s) from 8pm to 8am dramatically suppressed downy mildew development. In three experiments conducted during 2015, percent infected leaves in regular (non-fanned) net-houses reached a mean of 89.9, 94.3 and 96.0% compared to1.2, 1.7 and 0.5% in adjacent fanned net-houses, respectively. Nocturnal fanning reduced the number of hours per night with RH≥95% thus shortened the dew periods below the threshold required for infection or sporulation. In experiments A, B and C, the number of nights with ≥4h of RH≥95% was 28, 10 and 17 in the non-fanned net-houses compared to 5, 0 and 5 in the fanned net-houses, respectively. In the third experiment leaf wetness sensors were installed. Dew formation was strongly suppressed in the fanned net-house as compared to the non-fanned net-house. Healthy potted plants became infected and sporulated a week later if placed one night in the non-fanned house whereas healthy plants placed during that night in the fanned house remained healthy. Infected potted basil plants sporulated heavily after one night of incubation in the non-fanned house whereas almost no sporulation occurred in similar plants incubated that night in the fanned house. The data suggest that nocturnal fanning is highly effective in suppressing downy mildew epidemics in sweet basil. Fanning prevented the within-canopy RH from reaching saturation, reduced dew deposition on the leaves, and hence prevented both infection and sporulation of P. belbahrii. PMID:27171554
Pollutant deposition via dew in urban and rural environment, Cracow, Poland
NASA Astrophysics Data System (ADS)
Muskała, Piotr; Sobik, Mieczysław; Błaś, Marek; Polkowska, Żaneta; Bokwa, Anita
2015-01-01
This study is a comparative analysis of dew in rural and urban environment. Dew samples were collected between May and October, 2009 in two reference stations in southern Poland: Cracow and Gaik-Brzezowa. The investigation included comparison of volume and chemistry of the collected samples. Due to its formation mechanisms, dew is a good indicator of air pollution. Following parameters were analyzed in 159 collected samples: pH, electric conductivity, concentration of formaldehyde and phenols, concentration of NH4+, Ca2 +, K+, Na+, and Mg2 + cations and NO2-, NO3-, SO42 -, Cl-, F-, and PO43 - anions. The frequency of dew was approximately the same, both in urban and rural conditions reaching 43% of the measurement period. Dew intensity, expressed by volume, was on average two times larger in rural environment than in urban conditions. Urban landuse was recognized as the main factor reducing dew intensity in the urban station in comparison to the rural. Furthermore, the intensity of dew depended on synoptic scale air circulation at both measurement sites. As expected, samples collected in Cracow were much more polluted than the ones from Gaik-Brzezowa. The average TIC (Total Ionic Content) parameter was approximately 50% higher at the urban station. The pH in the rural station was more acidic. NO3- anions and Ca2 + cations were predominant in both measurement sites, however the participation of Ca2 + in Cracow was higher. NO3- indicates pollutions emitted by transport and industrial sources. The concentration of the analytes in both stations, as the volume, depended on air circulation direction. For Gaik-Brzezowa the highest TIC was observed mainly within southern circulation, while for Cracow the highest TIC was noted within both northern and southern. In general the rural station represented background pollution for the whole region and the pollution in Cracow was more dependent on local urban sources as transport or industry.
Intelligent Chilled Mirror Humidity Sensor
1988-12-01
measure- ments made 8 times each day (roughly 3000 measurements). 3. Accuracy of a dew point measurement is to be within 0.50C. Some means for warning of...unreliable and was eventually discarded from the tests. As a replacement, we chose a manually operated sling psychrometer (Assman Corp.) which, though...electronically to lengthen the useful time that measurements can be made between cleanings. Once the mirror becomes ex- cessively dirty, further
Low Relative Humidity in the Atmosphere
1989-01-01
occur [1]. Dew points in most standard metrorological data are calculated from measurements with psychrometers to determine wet-bulb and dry-bulb...variation existed in relation to the observed data during the day. Only one entire day was missing, and an interpolation was made between the...few sporadic reports at other hours. No attempt has been made to interpolate missing observations as was done for Yuma. Because of the large number of
Atmospheric Models For Over-Ocean Propagation Loss
2015-08-24
Radiosonde balloons are launched daily at selected loca- tions, and measure temperature, dew point temperature, and air pressure as they ascend. Radiosondes...different times of year and locations. The result was used to estimate high-reliability SHF/EHF air -to-surface radio link performance in a maritime...environment. I. INTRODUCTION Air -to-surface radio links differ from typical satellite com- munications links in that the path elevation angles are lower
Physical Processes in Coastal Stratocumulus Clouds from Aircraft Measurements During UPPEF 2012
2013-09-01
pressure, dew point, water vapor, absolute humidity, and carbon dioxide concentration. There were various upward and downward looking pyranometers ...Meteorological parameters IR Temperature -50 to +20 °C Up-looking modified Kipp & Zonen CM-22 pyranometer (CIRPAS/NRL) Meteorological parameters Down...welling Solar Irradiance 0-1400 W m -2 Down-looking modified Kipp & Zonen CM-22 pyranometer (CIRPAS/NRL) Meteorological parameters Up-welling Solar
Inventory of File naefs_geavg.t12z.ndgd_conusf06.grib2
Number of Records: 8 Number Level/Layer Parameter Forecast Valid Description 001 surface PRES 6 hour fcst Pressure [Pa] ens-mean 002 2 m above ground TMP 6 hour fcst Temperature [K] ens-mean 003 2 m above ground RH 6 hour fcst Relative Humidity [%] ens-mean 004 2 m above ground DPT 6 hour fcst Dew Point
Inventory of File naefs_geavg.t12z.ndgd_alaskaf06.grib
Number of Records: 8 Number Level/Layer Parameter Forecast Valid Description 001 surface PRES 6 hour fcst Pressure [Pa] ens-mean 002 2 m above ground TMP 6 hour fcst Temperature [K] ens-mean 003 2 m above ground RH 6 hour fcst Relative Humidity [%] ens-mean 004 2 m above ground DPT 6 hour fcst Dew Point
Efficiency and temperature dependence of water removal by membrane dryers
NASA Technical Reports Server (NTRS)
Leckrone, K. J.; Hayes, J. M.
1997-01-01
The vapor pressure of water in equilibrium with sorption sites within a Nafion membrane is given by log P(WN) = -3580/T + 10.01, where P(WN) is expressed in Torr and T is the membrane temperature, in kelvin. The efficiency of dryers based on selective permeation of water through Nafion can thus be enhanced by cooling the membrane. Residual water in effluents exceeds equilibrium levels if insufficient time is allowed for water to diffuse to the membrane surface as gas passes through the dryer. For tubular configurations, this limitation can be avoided if L > or = Fc(10(3.8)/120 pi D), where L is the length of the tubular membrane, in centimeters, Fc is the gas flow rate, in mL/ min, and D is the diffusion coefficient for water in the carrier gas at the operating temperature of the dryer, in cm2/s. An efficient dryer that at room temperature dries gas to a dew point of -61 degrees C is described; the same dryer maintained at 0 degrees C yields a dew point of -80 degrees C and removes water as effectively as Mg(ClO4)2 or a dry ice/acetone slush. The use of Nafion membranes to construct devices capable of delivering gas streams with low but precisely controlled humidities is discussed.
NASA Astrophysics Data System (ADS)
Hudoklin, D.; Šetina, J.; Drnovšek, J.
2012-09-01
The measurement of the water-vapor permeation rate (WVPR) through materials is very important in many industrial applications such as the development of new fabrics and construction materials, in the semiconductor industry, packaging, vacuum techniques, etc. The demand for this kind of measurement grows considerably and thus many different methods for measuring the WVPR are developed and standardized within numerous national and international standards. However, comparison of existing methods shows a low level of mutual agreement. The objective of this paper is to demonstrate the necessary uncertainty evaluation for WVPR measurements, so as to provide a basis for development of a corresponding reference measurement standard. This paper presents a specially developed measurement setup, which employs a precision dew-point sensor for WVPR measurements on specimens of different shapes. The paper also presents a physical model, which tries to account for both dynamic and quasi-static methods, the common types of WVPR measurements referred to in standards and scientific publications. An uncertainty evaluation carried out according to the ISO/IEC guide to the expression of uncertainty in measurement (GUM) shows the relative expanded ( k = 2) uncertainty to be 3.0 % for WVPR of 6.71 mg . h-1 (corresponding to permeance of 30.4 mg . m-2. day-1 . hPa-1).
NASA Astrophysics Data System (ADS)
Wang, Junhong; Carlson, David J.; Parsons, David B.; Hock, Terrence F.; Lauritsen, Dean; Cole, Harold L.; Beierle, Kathryn; Chamberlain, Edward
2003-08-01
This study evaluates performance of humidity sensors in two widely used operational radiosondes, Vaisala and Sippican (formally VIZ), in comparison with a research quality, and potentially more accurate, chilled mirror dew-point hygrometer named ``Snow White''. A research radiosonde system carrying the Snow White (SW) hygrometer was deployed in the Oklahoma panhandle and at Dodge City, KS during the International H2O Project (IHOP_2002). A total of sixteen sondes were launched with either Vaisala RS80 or Sippican VIZ-B2 radiosondes on the same balloons. Comparisons of humidity data from the SW with Vaisala and Sippican data show that (a) Vaisala RS80-H agrees with the SW very well in the middle and lower troposphere, but has dry biases in the upper troposphere (UT), (b) Sippican carbon hygristor (CH) has time-lag errors throughout the troposphere and fails to respond to humidity changes in the UT, sometimes even in the middle troposphere, and (c) the SW can detect cirrus clouds near the tropopause and possibly estimate their ice water content (IWC). The failure of CH in the UT results in significant and artificial humidity shifts in radiosonde climate records at stations where a transition from VIZ to Vaisala radiosondes has occurred.
NASA Astrophysics Data System (ADS)
Wasterlain, S.; Candusso, D.; Hissel, D.; Harel, F.; Bergman, P.; Menard, P.; Anwar, M.
A single PEMFC has been operated by varying the assembly temperature, the air dew point temperature and the anode/cathode stoichiometry rates with the aim to identify the parameters and combinations of factors affecting the cell performance. Some of the experiments were conducted with low humidified reactants (relative humidity of 12%). The FC characterizations tests have been conducted using in situ electrochemical methods based on load current and cell voltage signal analysis, namely: polarization curves, EIS measurements, cyclic and linear sweep voltammetries (CV and LSV). The impacts of the parameters on the global FC performances were observed using the polarization curves whereas EIS, CV and LSV test results were used to discriminate the different voltage loss sources. The test results suggest that some parameter sets allow maximal output voltages but can also induce material degradation. For instance, higher FC temperature and air flow values can induce significant electrical efficiency benefits, notably by increasing the reversible potential and the reaction kinetics. However, raising the cell temperature can also gradually dry the FC and increase the risk of membrane failure. LSV has also shown that elevated FC temperature and relative humidity can also accelerate the electrolyte degradation (i.e. slightly higher fuel crossover rate) and reduce the lifetime consequently.
Design and optimization of integrated gas/condensate plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Root, C.R.; Wilson, J.L.
1995-11-01
An optimized design is demonstrated for combining gas processing and condensate stabilization plants into a single integrated process facility. This integrated design economically provides improved condensate recovery versus use of a simple stabilizer design. A selection matrix showing likely application of this integrated process is presented for use on future designs. Several methods for developing the fluid characterization and for using a process simulator to predict future design compositions are described, which could be useful in other designs. Optimization of flowsheet equipment choices and of design operating pressures and temperatures is demonstrated including the effect of both continuous and discretemore » process equipment size changes. Several similar designs using a turboexpander to provide refrigeration for liquids recovery and stabilizer reflux are described. Operating overthrust and from the P/15-D platform in the Dutch sector of the North Sea has proven these integrated designs are effective. Concerns do remain around operation near or above the critical pressure that should be addressed in future work including providing conservative separator designs, providing sufficient process design safety margin to meet dew point specifications, selecting the most conservative design values of predicted gas dew point and equipment size calculated with different Equations-of-State, and possibly improving the accuracy of PVT calculations in the near critical area.« less
Huang, Zhenying; Boubriak, Ivan; Osborne, Daphne J.; Dong, Ming; Gutterman, Yitzchak
2008-01-01
Background and Aims Repair of damage to DNA of seed embryos sustained during long periods of quiescence under dry desert conditions is important for subsequent germination. The possibility that repair of embryo DNA can be facilitated by small amounts of water derived from dew temporarily captured at night by pectinaceous surface pellicles was tested. These pellicles are secreted during early seed development and form mucilage when hydrated. Methods Seeds of Artemisia sphaerocephala and Artemisia ordosica were collected from a sandy desert. Their embryos were damaged by gamma radiation to induce a standard level of DNA damage. The treated seeds were then exposed to nocturnal dew deposition on the surface of soil in the Negev desert highlands. The pellicles were removed from some seeds and left intact on others to test the ability of mucilage to support repair of the damaged DNA when night-time humidity and temperature favoured dew formation. Repair was assessed from fragmentation patterns of extracted DNA on agarose gels. Key Results For A. sphaerocephala, which has thick seed pellicles, DNA repair occurred in seeds with intact pellicles after 50 min of cumulative night dew formation, but not in seeds from which the pellicles had been removed. For A. ordosica, which has thin seed pellicles, DNA repair took at least 510 min of cumulative night dewing to achieve partial recovery of DNA integrity. The mucilage has the ability to rehydrate after daytime dehydration. Conclusions The ability of seeds to develop a mucilaginous layer when wetted by night-time dew, and to repair their DNA under these conditions, appear to be mechanisms that help maintain seed viability under harsh desert conditions. PMID:17495979
Huang, Zhenying; Boubriak, Ivan; Osborne, Daphne J; Dong, Ming; Gutterman, Yitzchak
2008-01-01
Repair of damage to DNA of seed embryos sustained during long periods of quiescence under dry desert conditions is important for subsequent germination. The possibility that repair of embryo DNA can be facilitated by small amounts of water derived from dew temporarily captured at night by pectinaceous surface pellicles was tested. These pellicles are secreted during early seed development and form mucilage when hydrated. Seeds of Artemisia sphaerocephala and Artemisia ordosica were collected from a sandy desert. Their embryos were damaged by gamma radiation to induce a standard level of DNA damage. The treated seeds were then exposed to nocturnal dew deposition on the surface of soil in the Negev desert highlands. The pellicles were removed from some seeds and left intact on others to test the ability of mucilage to support repair of the damaged DNA when night-time humidity and temperature favoured dew formation. Repair was assessed from fragmentation patterns of extracted DNA on agarose gels. For A. sphaerocephala, which has thick seed pellicles, DNA repair occurred in seeds with intact pellicles after 50 min of cumulative night dew formation, but not in seeds from which the pellicles had been removed. For A. ordosica, which has thin seed pellicles, DNA repair took at least 510 min of cumulative night dewing to achieve partial recovery of DNA integrity. The mucilage has the ability to rehydrate after daytime dehydration. The ability of seeds to develop a mucilaginous layer when wetted by night-time dew, and to repair their DNA under these conditions, appear to be mechanisms that help maintain seed viability under harsh desert conditions.
Determining osmotic pressure of drug solutions by air humidity in equilibrium method.
Zhan, Xiancheng; Li, Hui; Yu, Lan; Wei, Guocui; Li, Chengrong
2014-06-01
To establish a new osmotic pressure measuring method with a wide measuring range. The osmotic pressure of drug solutions is determined by measuring the relative air humidity in equilibrium with the solution. The freezing point osmometry is used as a control. The data obtained by the proposed method are comparable to those by the control method, and the measuring range of the proposed method is significantly wider than that of the control method. The proposed method is performed in an isothermal and equilibrium state, so it overcomes the defects of the freezing point and dew point osmometries which result from the heterothermal process in the measurement, and therefore is not limited to diluted solutions.
NASA Astrophysics Data System (ADS)
Chaouch, Naira; Temimi, Marouane; Weston, Michael; Ghedira, Hosni
2017-05-01
In this study, we intercompare seven different PBL schemes in WRF in the United Arab Emirates (UAE) and we assess their impact on the performance of the simulations. The study covered five fog events reported in 2014 at Abu Dhabi International Airport. The analysis of Synoptic conditions indicated that during all examined events, the UAE was under a high geopotential pressure and light wind that does not exceed 7 m/s at 850 hPa ( 1.5 km). Seven PBL schemes, namely, Yonsei University (YSU), Mellor-Yamada-Janjic (MYJ), Moller-Yamada Nakanishi and Niino (MYNN) level 2.5, Quasi-Normal Scale Elimination (QNSE-EDMF), Asymmetric Convective Model (ACM2), Grenier-Bretherton-McCaa (GBM) and MYNN level 3 were tested. In situ observations used in the model's assessment included radiosonde data from the Abu Dhabi International Airport and surface measurements of relative humidity (RH), dew point temperature, wind speed, and temperature profiles. Overall, all the tested PBL schemes showed comparable skills with relatively higher performance with the QNSE scheme. The average RH Root Mean Square Error (RMSE) and BIAS for all PBLs were 15.75% and - 9.07%, respectively, whereas the obtained RMSE and BIAS when QNSE was used were 14.65% and - 6.3% respectively. Comparable skills were obtained for the rest of the variables. Local PBL schemes showed better performance than non-local schemes. Discrepancies between simulated and observed values were higher at the surface level compared to high altitude values. The sensitivity to lead time showed that best simulation performances were obtained when the lead time varies between 12 and 18 h. In addition, the results of the simulations show that better performance is obtained when the starting condition is dry.
Pines, M K; Phillips, C J C
2013-09-01
The microclimate can potentially impact the health and welfare of livestock exported by ship. Within-pen microclimatic conditions were recorded and the effects of ammonia on sheep behavior investigated on a voyage from Australia to the Middle East. Ammonia, carbon dioxide, and hydrogen sulfide as well as wet-bulb, dry-bulb, and dew-point temperature and air speed were mapped in 20 open-deck focal pens, with the focus on the behavior and location of a marked sheep in each pen. Air speed was highly variable in most pens, with pockets of high but transient concentrations of ammonia (30.7 to 44.2 mg/m(3)) in 20% of pens that had no or minimal air flow. Carbon dioxide concentrations varied in some pens, but overall concentrations of carbon dioxide and hydrogen sulfide were low. Sheep in pens previously identified to have high ammonia concentrations, high wet-bulb temperatures, and low wind speed stood longer (P = 0.003) and spent less time feeding (P = 0.01) and ruminating (P = 0.004) than those in pens previously identified with low ammonia, low wet-bulb temperature, and high wind speed. Moreover, sheep exposed to increased ammonia concentrations held their head higher (P = 0.004) to avoid the greater ammonia concentrations at lower heights, and these sheep had more conjunctivitis (P < 0.001). Sheep movement around the pen was limited. Increased time spent lying down (P = 0.04) and more rhythmical behavior in the second half of the voyage indicated that the sheep adjusted to shipboard conditions over time. It is concluded that high, transient concentrations of ammonia existed in some pens, which adversely affected the behavior of sheep.
Large Dew water collectors in a village of S-Morocco (Idouasskssou)
NASA Astrophysics Data System (ADS)
Lekouch, I.; Clus, O.; Durand, M.; Lanfourmi, M.; Muselli, M.; Milimouk, I.; Beysens, D.
2010-07-01
With precipitations close to 227 mm/year in average, the coastal region of south Morocco presents a chronically shortage of drinkable and fresh water. Since 1994, in the Mirleft area (150 km south of Agadir), inhabitants are facing a critically drought event. In the year 2007, only 49 mm of rain was recorded. However, measurements in Mirleft in the same year, showed that the dew yield was on order of 40 % of rain fall. In order to show to the local population the interest of recovering dew water in addition to rain water, a small nearby village (Idouasskssou, 8 km SE of Mirleft) was equipped with three pilot condensers of 136 m2 total surface area. In order to ensure a good integration of the project by the village inhabitants, a local organization (Association IMRJANE) collaborated to the project. A concrete tank at ground level with a flat horizontal surface, easily accessible for inhabitants and also a model for traditional Morocco terrace roofings, has been equipped with two lines of condensers (40.6 m²). All roofing materials were from local shops. Only the special radiative and hydrophilic coating was coming from non local resources (see www.opur.fr). The top of a second tank (aside the first one) was renovated and covered with a 21.2 m² two slopes steel roof, insulated and painted with the special dew coating as above. These roofs represent a condensation surface comparable to that of a very little house. A third condenser, with 73.8 m² surface area, was implemented directly on the ground, ensuring minimal work and very cheap implementation costs. Dew was collected and measured in one of the concrete tanks. The water production during 6 months, from 15-12-2008 to 31-07-2009 (137 dew events, 47 % of days) was more than 3800 L (more than 0.2 mm/dew day). It is important to note that, while the devices are specifically designed to condense dew water, they also harvest rain and fog as well, thus providing to the population a valuable water resource.
Mach-Number Measurement with Laser and Pressure Probes in Humid Supersonic Flow
NASA Technical Reports Server (NTRS)
Herring, G. C.
2008-01-01
Mach-number measurements using a nonintrusive optical technique, laser-induced thermal acoustics (LITA), are compared to pressure probes in humid supersonic airflow. The two techniques agree well in dry flow (-35 C dew point), but LITA measurements show about five times larger fractional change in Mach number than that of the pressure-probe when water is purposefully introduced into the flow. Possible reasons for this discrepancy are discussed.
NASA Technical Reports Server (NTRS)
Roberts, Barry C.
2004-01-01
Supported Return-to-Flight activities by providing surface climate data from Kennedy Space Center used primarily for ice and dew formation studies, and upper air wind analysis primarily used for ascent loads analyses. The MSFC Environments Group's Terrestrial and Planetary Environments Team documented Space Shuttle day-of-launch support activities by publishing a document in support of SSP Return-to-Flight activities entitled "Space Shuttle Program Flight Operations Support". The team also formalized the Shuttle Natural Environments Technical Panel and chaired the first special session of the SSP Natural Environments Panel meeting at KSC, November 4-7,2003.58 participants from NASA, DOD and other government agencies from across the country attended the meeting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleinman L. I.; Daum, P. H.; Lee, Y.-N.
2012-01-04
During the VOCALS Regional Experiment, the DOE G-1 aircraft was used to sample a varying aerosol environment pertinent to properties of stratocumulus clouds over a longitude band extending 800 km west from the Chilean coast at Arica. Trace gas and aerosol measurements are presented as a function of longitude, altitude, and dew point in this study. Spatial distributions are consistent with an upper atmospheric source for O{sub 3} and South American coastal sources for marine boundary layer (MBL) CO and aerosol, most of which is acidic sulfate. Pollutant layers in the free troposphere (FT) can be a result of emissionsmore » to the north in Peru or long range transport from the west. At a given altitude in the FT (up to 3 km), dew point varies by 40 C with dry air descending from the upper atmospheric and moist air having a boundary layer (BL) contribution. Ascent of BL air to a cold high altitude results in the condensation and precipitation removal of all but a few percent of BL water along with aerosol that served as CCN. Thus, aerosol volume decreases with dew point in the FT. Aerosol size spectra have a bimodal structure in the MBL and an intermediate diameter unimodal distribution in the FT. Comparing cloud droplet number concentration (CDNC) and pre-cloud aerosol (D{sub p} > 100 nm) gives a linear relation up to a number concentration of {approx}150 cm{sup -3}, followed by a less than proportional increase in CDNC at higher aerosol number concentration. A number balance between below cloud aerosol and cloud droplets indicates that {approx}25 % of aerosol with D{sub p} > 100 nm are interstitial (not activated). A direct comparison of pre-cloud and in-cloud aerosol yields a higher estimate. Artifacts in the measurement of interstitial aerosol due to droplet shatter and evaporation are discussed. Within each of 102 constant altitude cloud transects, CDNC and interstitial aerosol were anti-correlated. An examination of one cloud as a case study shows that the interstitial aerosol appears to have a background, upon which is superimposed a high frequency signal that contains the anti-correlation. The anti-correlation is a possible source of information on particle activation or evaporation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kleinman, L.I.; Daum, P. H.; Lee, Y.-N.
2011-06-21
During the VOCALS Regional Experiment, the DOE G-1 aircraft was used to sample a varying aerosol environment pertinent to properties of stratocumulus clouds over a longitude band extending 800 km west from the Chilean coast at Arica. Trace gas and aerosol measurements are presented as a function of longitude, altitude, and dew point in this study. Spatial distributions are consistent with an upper atmospheric source for O{sub 3} and South American coastal sources for marine boundary layer (MBL) CO and aerosol, most of which is acidic sulfate in agreement with the dominant pollution source being SO{sub 2} from Cu smeltersmore » and power plants. Pollutant layers in the free troposphere (FT) can be a result of emissions to the north in Peru or long range transport from the west. At a given altitude in the FT (up to 3 km), dew point varies by 40 C with dry air descending from the upper atmospheric and moist air having a BL contribution. Ascent of BL air to a cold high altitude results in the condensation and precipitation removal of all but a few percent of BL water along with aerosol that served as CCN. Thus, aerosol volume decreases with dew point in the FT. Aerosol size spectra have a bimodal structure in the MBL and an intermediate diameter unimodal distribution in the FT. Comparing cloud droplet number concentration (CDNC) and pre-cloud aerosol (Dp > 100 nm) gives a linear relation up to a number concentration of {approx}150 cm{sup -3}, followed by a less than proportional increase in CDNC at higher aerosol number concentration. A number balance between below cloud aerosol and cloud droplets indicates that {approx}25% of aerosol in the PCASP size range are interstitial (not activated). One hundred and two constant altitude cloud transects were identified and used to determine properties of interstitial aerosol. One transect is examined in detail as a case study. Approximately 25 to 50% of aerosol with D{sub p} > 110 nm were not activated, the difference between the two approaches possibly representing shattered cloud droplets or unknown artifact. CDNC and interstitial aerosol were anti-correlated in all cloud transects, consistent with the occurrence of dry in-cloud areas due to entrainment or circulation mixing.« less
Digital Earth Watch: Investigating the World with Digital Cameras
NASA Astrophysics Data System (ADS)
Gould, A. D.; Schloss, A. L.; Beaudry, J.; Pickle, J.
2015-12-01
Every digital camera including the smart phone camera can be a scientific tool. Pictures contain millions of color intensity measurements organized spatially allowing us to measure properties of objects in the images. This presentation will demonstrate how digital pictures can be used for a variety of studies with a special emphasis on using repeat digital photographs to study change-over-time in outdoor settings with a Picture Post. Demonstrations will include using inexpensive color filters to take pictures that enhance features in images such as unhealthy leaves on plants, or clouds in the sky. Software available at no cost from the Digital Earth Watch (DEW) website that lets students explore light, color and pixels, manipulate color in images and make measurements, will be demonstrated. DEW and Picture Post were developed with support from NASA. Please visit our websites: DEW: http://dew.globalsystemsscience.orgPicture Post: http://picturepost.unh.edu
2005-03-01
47 Figure 21. Construction of the long heat exchanger with helical rod welded in place.... 48 Figure 22. Heat exchanger...not at a temperature at or above the dew point temperature of the mixture, some of the fuel in the mixture will re- condense . The concept of...diao (25) Where kamb = Thermal conductivity of the air [W/(m-K)] Nufc = Nusselt number for free convection The Nussult number
Satellite freeze forecast system
NASA Technical Reports Server (NTRS)
Martsolf, J. D. (Principal Investigator)
1983-01-01
Provisions for back-up operations for the satellite freeze forecast system are discussed including software and hardware maintenance and DS/1000-1V linkage; troubleshooting; and digitized radar usage. The documentation developed; dissemination of data products via television and the IFAS computer network; data base management; predictive models; the installation of and progress towards the operational status of key stations; and digital data acquisition are also considered. The d addition of dew point temperature into the P-model is outlined.
NASA Astrophysics Data System (ADS)
Fang, Jing
2014-05-01
Besides the absorption by roots from the soil substrate, it has long been known that plants exhibit alternative water-absorption strategies, particularly in drought-prone environments. For many tropical epiphytic orchids, air moisture can be absorbed directly by aerial roots. Some conifers are also found to utilize air moisture by foliar absorption during the summer fog season. However, few studies have been carried out on the atmospheric water vapor absorption by shallow-rooted desert plants. We conducted experiments in desert-oasis ecotone and investigated the effects of dew absorbed by three kinds of shallow-rooted seedlings on net photosynthesis rate, as well as on other water relations variables. Three kinds of typical shallow-rooted desert species (Bassia dasyphylla, Salsola collina and Corispermum declinatum) have been chosen and potted. Each species were subjected to contrasting watering regimes (normal and deficient) and different air moisture conditions (having dew and having no dew) for 10 weeks. Net photosynthesis rate was measured on six occasions during the study. Other water relations variables (midday shoot water potential, relative water content, stomatal conductance) were also measured. Under the dew conditions, average net photosynthesis rate, shoot water potential, leaf relative water content and stomatal conductance increased, with greater responses observed for plants subjected to a deficient watering regime than for well-watered plants. These results indicated dew occurred in arid region could be utilized through foliar absorption by some shallow-rooted plants, and for the shallow-rooted plants, the presence of dew could significantly relieve the deficit of water in water-stressed regime.
A frost formation model and its validation under various experimental conditions
NASA Technical Reports Server (NTRS)
Dietenberger, M. A.
1982-01-01
A numerical model that was used to calculate the frost properties for all regimes of frost growth is described. In the first regime of frost growth, the initial frost density and thickness was modeled from the theories of crystal growth. The 'frost point' temperature was modeled as a linear interpolation between the dew point temperature and the fog point temperature, based upon the nucleating capability of the particular condensing surfaces. For a second regime of frost growth, the diffusion model was adopted with the following enhancements: the generalized correlation of the water frost thermal conductivity was applied to practically all water frost layers being careful to ensure that the calculated heat and mass transfer coefficients agreed with experimental measurements of the same coefficients.
7 CFR 51.3741 - U.S. Commercial.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Honey Dew and Honey Ball Type Melons Grades § 51.3741 U.S. Commercial. “U.S. Commercial” consists of honey dew or honey ball type melons which meet the requirements of U.S. No. 1 grade...
7 CFR 51.3741 - U.S. Commercial.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Honey Dew and Honey Ball Type Melons Grades § 51.3741 U.S. Commercial. “U.S. Commercial” consists of honey dew or honey ball type melons which meet the requirements of U.S. No. 1 grade...
Hierarchical structures of cactus spines that aid in the directional movement of dew droplets.
Malik, F T; Clement, R M; Gethin, D T; Kiernan, M; Goral, T; Griffiths, P; Beynon, D; Parker, A R
2016-08-06
Three species of cactus whose spines act as dew harvesters were chosen for this study: Copiapoa cinerea var. haseltoniana, Mammillaria columbiana subsp. yucatanensis and Parodia mammulosa and compared with Ferocactus wislizenii whose spines do not perform as dew harvesters. Time-lapse snapshots of C. cinerea showed movement of dew droplets from spine tips to their base, even against gravity. Spines emanating from one of the areoles of C. cinerea were submerged in water laced with fluorescent nanoparticles and this particular areole with its spines and a small area of stem was removed and imaged. These images clearly showed that fluorescent water had moved into the stem of the plant. Lines of vascular bundles radiating inwards from the surface areoles (from where the spines emanate) to the core of the stem were detected using magnetic resonance imaging, with the exception of F. wislizenii that does not harvest dew on its spines. Spine microstructures were examined using SEM images and surface roughness measurements (Ra and Rz) taken of the spines of C. cinerea It was found that a roughness gradient created by tapered microgrooves existed that could potentially direct surface water from a spine tip to its base.This article is part of the themed issue 'Bioinspired hierarchically structured surfaces for green science'. © 2016 The Author(s).
Hierarchical structures of cactus spines that aid in the directional movement of dew droplets
Clement, R. M.; Gethin, D. T.; Kiernan, M.; Goral, T.; Griffiths, P.; Beynon, D.; Parker, A. R.
2016-01-01
Three species of cactus whose spines act as dew harvesters were chosen for this study: Copiapoa cinerea var. haseltoniana, Mammillaria columbiana subsp. yucatanensis and Parodia mammulosa and compared with Ferocactus wislizenii whose spines do not perform as dew harvesters. Time-lapse snapshots of C. cinerea showed movement of dew droplets from spine tips to their base, even against gravity. Spines emanating from one of the areoles of C. cinerea were submerged in water laced with fluorescent nanoparticles and this particular areole with its spines and a small area of stem was removed and imaged. These images clearly showed that fluorescent water had moved into the stem of the plant. Lines of vascular bundles radiating inwards from the surface areoles (from where the spines emanate) to the core of the stem were detected using magnetic resonance imaging, with the exception of F. wislizenii that does not harvest dew on its spines. Spine microstructures were examined using SEM images and surface roughness measurements (Ra and Rz) taken of the spines of C. cinerea. It was found that a roughness gradient created by tapered microgrooves existed that could potentially direct surface water from a spine tip to its base. This article is part of the themed issue ‘Bioinspired hierarchically structured surfaces for green science’. PMID:27354735
NASA Astrophysics Data System (ADS)
Sheffield, A. M.; Marrs, A.; Wall, T. U.; Cayan, D.; Kalansky, J.; Redmond, K. T.; Huntington, J. L.; McEvoy, D.
2016-12-01
In California and Nevada, a diverse set of sectors and regional variation amidst a 5-year spell of drought presents multiple needs, gaps and challenges in providing usable available information for drought preparedness. In response to the findings of Governor Sandoval's Nevada Drought Forum and a series of stakeholder meetings and drought and climate outlooks in California, NOAA's National Integrated Drought Information System (NIDIS) has created the California-Nevada DEWS to leverage the activities of the existing California DEWS to better reflect the needs of the region after five years of unprecedented drought. In addition to presenting timely drought status and outlooks, these stakeholder-oriented meetings and listening sessions explored local drought impacts and drought informational needs. The information gathered will be integrated into a strategic plan for California-Nevada DEWS. This strategic plan will provide a roadmap of planned research and activities to enhance the ability of stakeholders in the region to better plan, prepare for and mitigate the impacts of drought. The implementation will involve key partners from a diverse network of federal, regional, tribal, state and local agencies and interests and will result in regionally specific deliverables to advance the California-Nevada DEWS.
Correction of Thermal Gradient Errors in Stem Thermocouple Hygrometers
Michel, Burlyn E.
1979-01-01
Stem thermocouple hygrometers were subjected to transient and stable thermal gradients while in contact with reference solutions of NaCl. Both dew point and psychrometric voltages were directly related to zero offset voltages, the latter reflecting the size of the thermal gradient. Although slopes were affected by absolute temperature, they were not affected by water potential. One hygrometer required a correction of 1.75 bars water potential per microvolt of zero offset, a value that was constant from 20 to 30 C. PMID:16660685
AVGAS/AUTOGAS (Aviation Gasoline/Automobile Gasoline) Comparison. Winter Grade Fuels.
1986-07-01
mass MAP Manifold pressure - inHg MON Motor Octane Number NIPER National Institute of Petroleum and Energy Resources Pamb Ambient pressure - inHg...pressure - psig si Sea level (used as a subscript) STC Supplemental Type Certificate Tamb Ambient temperature - degC or degF Tdew Dew point - degC or degF...temperature deg C #2 exhaust gas temperature deg C #3 exhaust gas temperature deg C #4 exhaust gas temperature deg C Ambient air temperature deg C 6
Toxic Industrial Chemical Removal by Isostructural Metal-Organic Frameworks
2011-01-01
similar to H- ZSM -5. Fifteen control runs were performed over 8 months using approximately 35 mg of adsorbent and bead height of approximately 4 mm...from 1.5 - 60° with an exposure time of 10 s per step. No peaks could be resolved from the baseline for 20 > 35 °; therefore, this region was not...experiment, to evaluate the desorption behavior of the material. The dry air used in these experiments had a dew point of approximately - 35 °C. In all
NASA Technical Reports Server (NTRS)
Smith, Eric A.; Crosson, William L.; Tanner, Bertrand D.
1992-01-01
Attention is focused on in situ measurements taken during FIFE required to support the development and validation of a biosphere model. Seasonal time series of surface flux measurements obtained from two surface radiation and energy budget stations utilized to support the FIFE surface flux measurement subprogram are examined. Data collection and processing procedures are discussed along with the measurement analysis for the complete 1987 test period.
Investigation of JP-8 Autoignition Under Vitiated Combustion Conditions
2011-01-01
no less than 1.5 times the dew point temperature of the mixture for all test cases that involved H2O. The flow path and apparatus for the steam...Variable m Interaction Effect of Design Variables m and n R Universal Gas Constant [cal/mol-K] E Activation Energy of Ignition Process [cal/mol] T...combustion including CO2, CO, H2O, and NOX. Vitiated conditions are often the result of flue or exhaust gas recirculation (EGR) into a fresh air stream
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karmi, S.
1996-03-18
This document contains the baseline human health risk assessment and the ecological risk assessment (ERA) for the Bullen Point Distant Early Warning (DEW) Line radar installation. Five sites at the Bullen Point radar installation underwent remedial investigations (RIs) during the summer of 1993. The presence of chemical contamination in the soil, sediments, and surface water at the installation was evaluated and reported in the Bullen Point Remedial Investigation/Feasibility Study (RI/FS) (U.S. Air Force 1996). The analytical data reported in the RI/FS form the basis for the human health and ecological risk assessments. The primary chemicals of concern (COCs) at themore » five sites are diesel and gasoline from past spills and/or leaks.« less
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Honey Dew and Honey Ball Type Melons Grades § 51.3740 U.S. No. 1. “U.S. No. 1” consists of honey dew or honey ball type melons which are mature, firm, well formed, which are free from...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Honey Dew and Honey Ball Type Melons Grades § 51.3742 U.S. No. 2. “U.S. No. 2” consists of honey dew or honey ball type melons which are mature, firm, fairly well formed, free from decay...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Honey Dew and Honey Ball Type Melons Grades § 51.3740 U.S. No. 1. “U.S. No. 1” consists of honey dew or honey ball type melons which are mature, firm, well formed, which are free from...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Honey Dew and Honey Ball Type Melons Grades § 51.3742 U.S. No. 2. “U.S. No. 2” consists of honey dew or honey ball type melons which are mature, firm, fairly well formed, free from decay...
Solubilized wheat protein isolate: functional properties and potential food applications.
Ahmedna, M; Prinyawiwatkul, W; Rao, R M
1999-04-01
Solubility, foaming capacity/stability, water holding and fat absorption capacities, and emulsifying capacity/stability of a solubilized wheat protein isolate (SWPI) were compared with those of commercial protein, that is, sodium caseinate (NaCAS), dried egg white (DEW), nonfat dry milk (NFDM), and soy protein isolate (SPI). SWPI was highly soluble at pH 6.5-8.5. Foaming capacity of SWPI was superior to those of SPI, NFDM, and DEW, and its foaming stability was similar to those of the commercial proteins. Foaming properties of SWPI were greatly improved in the presence of 0.5% (w/v) CaCl(2). Water holding capacity of SWPI was greater than that of NaCAS, NFDM, and DEW, whereas its fat absorption capacity was comparable to that of SPI, NaCAS, and DEW. SWPI exhibited emulsifying properties similar to those of SPI. SWPI was incorporated at 5, 10, 15, or 20% into ice cream, chocolate chip cookies, banana nut muffins, and hamburger patties. Products containing <5% SWPI were acceptable to consumers.
Joint Optics Structures Experiment (JOSE)
NASA Technical Reports Server (NTRS)
Founds, David
1987-01-01
The objectives of the JOSE program is to develop, demonstrate, and evaluate active vibration suppression techniques for Directed Energy Weapons (DEW). DEW system performance is highly influenced by the line-of-sight (LOS) stability and in some cases by the wave front quality. The missions envisioned for DEW systems by the Strategic Defense Initiative require LOS stability and wave front quality to be significantly improved over any current demonstrated capability. The Active Control of Space Structures (ACOSS) program led to the development of a number of promising structural control techniques. DEW structures are vastly more complex than any structures controlled to date. They will be subject to disturbances with significantly higher magnitudes and wider bandwidths, while holding higher tolerances on allowable motions and deformations. Meeting the performance requirements of the JOSE program requires upgrading the ACOSS techniques to meet new more stringent requirements, the development of requisite sensors and acturators, improved control processors, highly accurate system identification methods, and the integration of hardware and methodologies into a successful demonstration.
NASA Technical Reports Server (NTRS)
Huddleston, Lisa; Maier, Launa; Smith, Kristin; Roeder, William P.; McAleenan, Mike; Winters, Katherine A.; Godoy, Laura M.; Hinkley, Jeremy
2017-01-01
For evaluation of the potential of cloud electrification, it is necessary to know the altitude of the 0, -10 and -20 degree Celsius levels. Cape Canaveral Air Force Station has recorded balloon launch data back to 1989. In support of rocket launches, often multiple balloons are launched within minutes of each other in the 4-6 hours leading up to launch. In the past, temperature data from sondes was typically available every hour or so through the launch countdown, allowing for frequent updates of these critical temperature thresholds. Recently, launch customers are relying on jimsphere and wind profiler data that do not have a thermodynamic component in the latter 4-6 hours of a countdown. This study compares the altitude differences of the 0, -10 and -20 degree Celsius levels from GPS-tracked consecutive balloon pairs not to exceed 6 hours apart. The analysis uses 3,198 soundings from 2001 to 2013. Approximately 20, 17, and 13 percent of the time the altitude of the temperature level in question (0, -10, -20 degrees C respectively), varies by more than 500 feet (operationally significant threshold) within 6 hours. This study analyzes the altitude variability as a function of several meteorological parameters, such as dew point depression and solar zenith angle. Additionally, the study concludes with impacts to launch operations.
Seasonal simulations using a coupled ocean-atmosphere model with data assimilation
NASA Astrophysics Data System (ADS)
Larow, Timothy Edward
1997-10-01
A coupled ocean-atmosphere initialization scheme using Newtonian relaxation has been developed for the Florida State University coupled ocean-atmosphere global general circulation model. The coupled model is used for seasonal predictions of the boreal summers of 1987 and 1988. The atmosphere model is a modified version of the Florida State University global spectral model, resolution triangular truncation 42 waves. The ocean general circulation model consists of a slightly modified version developed by Latif (1987). Coupling is synchronous with exchange of information every two model hours. Using daily analysis from ECMWF and observed monthly mean SSTs from NCEP, two - one year, time dependent, Newtonian relaxation were conducted using the coupled model prior to the seasonal forecasts. Relaxation was selectively applied to the atmospheric vorticity, divergence, temperature, and dew point depression equations, and to the ocean's surface temperature equation. The ocean's initial conditions are from a six year ocean-only simulation which used observed wind stresses and a relaxation towards observed SSTs for forcings. Coupled initialization was conducted from 1 June 1986 to 1 June 1987 for the 1987 boreal forecast and from 1 June 1987 to 1 June 1988 for the 1988 boreal forecast. Examination of annual means of net heat flux, freshwater flux and wind stress obtained by from the initialization show close agreement with Oberhuber (1988) climatology and the Florida State University pseudo wind stress analysis. Sensitivity of the initialization/assimilation scheme was tested by conducting two - ten member ensemble integrations. Each member was integrated for 90 days (June-August) of the respective year. Initial conditions for the ensembles consisted of the same ocean state as used by the initialize forecasts, while the atmospheric initial conditions were from ECMWF analysis centered on 1 June of the respective year. Root mean square error and anomaly correlations between observed and forecasted SSTs in the Nino 3 and Nino 4 regions show greater skill between the initialized forecasts than the ensemble forecasts. It is hypothesized that differences in the specific humidity within the planetary boundary layer are responsible for the large SST errors noted with the ensembles.
[Examination of upper airway function using the dew point hygrometer with semiconductor detector].
Weremczuk, Jerzy; Paczesny, Daniel; Rapiejko, Piotr; Jachowicz, Ryszard; Jurkiewicz, Dariusz
2005-09-01
The nasal mucosa with blood capillary network has a remarkable role in respiration process. The most important nose functions are heating and humidifying to optimal level of reaching throat and lungs air and partly absorption of humidity and temperature from expired air. Variations of humidifying and heating processes can invoke some upper airways disorders. The paper presents dew point hygrometer which was specially design for laryngological purposes. The hygrometer can measure dynamic changes of humidity in upper airways. The device is fully automated, easy to operate and can communicate with external personal computer. Database application allows saving patient data with archive examination results and can display them easily. During ongoing clinical tests, still increasing amount of data will allow precisely investigate correlations between humidifying process and some diseases. The main advantage of the device is a short response time on humidity changing. The number of readings (detections) can reach 5 readings per second (slightly depending on humidity level) which is much faster than in available on the market hygrometers with sorption sensors. The paper also presents some results obtained in group of healthy volunteers and one patient with tracheostomy The tests figured out actual humidity in certain parts of upper airways: nose, throat, trachea in breathing cycles under various surrounding conditions. The constructed hygrometer can be used for air humidity measurement in upper airways during some diseases and for evaluation of an influence of some drugs and environmental conditions changing on air upper ways mucosa.
Drier Air, Lower Temperatures, and Triggering of Paroxysmal Atrial Fibrillation
Nguyen, Jennifer L.; Link, Mark S.; Luttmann-Gibson, Heike; Laden, Francine; Schwartz, Joel; Wessler, Benjamin S.; Mittleman, Murray A.; Gold, Diane R.; Dockery, Douglas W.
2015-01-01
Background The few previous studies on the onset of paroxysmal atrial fibrillation and meteorologic conditions have focused on outdoor temperature and hospital admissions, but hospital admissions are a crude indicator of atrial fibrillation incidence, and studies have found other weather measures in addition to temperature to be associated with cardiovascular outcomes. Methods Two hundred patients with dual chamber implantable cardioverter-defibrillators were enrolled and followed prospectively from 2006 to 2010 for new onset episodes of atrial fibrillation. The date and time of arrhythmia episodes documented by the implanted cardioverter-defibrillators were linked to meteorologic data and examined using a case-crossover analysis. We evaluated associations with outdoor temperature, apparent temperature, air pressure, and three measures of humidity (relative humidity, dew point, and absolute humidity). Results Of the 200 enrolled patients, 49 patients experienced 328 atrial fibrillation episodes lasting ≥30 seconds. Lower temperatures in the prior 48 hours were positively associated with atrial fibrillation. Lower absolute humidity (ie, drier air) had the strongest and most consistent association: each 0.5 g/m3 decrease in the prior 24 hours increased the odds of atrial fibrillation by 4% (95% confidence interval [CI]: 0%, 7%) and by 5% (95% CI: 2%, 8%) for exposure in the prior 2 hours. Results were similar for dew point but slightly weaker. Conclusions Recent exposure to drier air and lower temperatures were associated with the onset of atrial fibrillation among patients with known cardiac disease, supporting the hypothesis that meteorologic conditions trigger acute cardiovascular episodes. PMID:25756220
Environmental dew point and skin and lip weathering.
Devillers, C; Piérard, G E; Quatresooz, P; Piérard, S
2010-05-01
Xerosis represents a physiological response of the stratum corneum (SC) to environmental threats. The influence of the environmental dew point (DP) is not fully understood. This parameter is the air temperature at which the relative humidity is maximum. This study aimed to assess the relationship between the environmental DP and the water-holding capacity of the skin and lower lip vermilion. For comparison, SC property was evaluated after occlusive application of cooled and uncooled hydrogel pads. Electrometric measurements using a dermal phase meter (DPM) device were performed on the back of the hands, the cheeks and the lower lip of 40 healthy menopausal women. Assessments were performed in the outdoor conditions during winter and spring. The same measurements were recorded after hydrogel pads, at room temperature or cooled to 4 degrees C, were placed for 15 min on the test sites. The environmental DP was recorded at each evaluation time. The SC water-holding capacity was discretely influenced by the DP. In the open-air environmental conditions, a positive linear relationship was found on the cheeks between the DP and DPM values. The relationship was weaker on the lips. Conversely, a consistent increase in DPM values was recorded immediately after removal of the cooled and uncooled hydrogel pads. The observations made in the open-air testing conditions are consistent with the predicted events following the Arrhenius law. By contrast, the combination of cooling and occlusion by the hydrogel pads is responsible for the reverse effect on the SC.
Investigation on the pinch point position in heat exchangers
NASA Astrophysics Data System (ADS)
Pan, Lisheng; Shi, Weixiu
2016-06-01
The pinch point is important for analyzing heat transfer in thermodynamic cycles. With the aim to reveal the importance of determining the accurate pinch point, the research on the pinch point position is carried out by theoretical method. The results show that the pinch point position depends on the parameters of the heat transfer fluids and the major fluid properties. In most cases, the pinch point locates at the bubble point for the evaporator and the dew point for the condenser. However, the pinch point shifts to the supercooled liquid state in the near critical conditions for the evaporator. Similarly, it shifts to the superheated vapor state with the condensing temperature approaching the critical temperature for the condenser. It even can shift to the working fluid entrance of the evaporator or the supercritical heater when the heat source fluid temperature is very high compared with the absorbing heat temperature. A wrong position for the pinch point may generate serious mistake. In brief, the pinch point should be founded by the iterative method in all conditions rather than taking for granted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karmi, S.
1996-04-15
This document contains the baseline human health risk assessment and the ecological risk assessment (ERA) for the Oliktok Point Distant Early Warning (DEW) Line radar installation. Eight sites at the Oliktok Point radar installation underwent remedial investigations (RIs) during the summer of 1993. The presence of chemical contamination in the soil, sediments, and surface water at the installation was evaluated and reported in the Oliktok Point Remedial Investigation/Feasibility Study (RI/FS) (U.S. Air Force 1996). The analytical data reported in the RI/FS form the basis for the human health and ecological risk assessments. The primary chemicals of concern (COCs) at themore » eight sites are diesel and gasoline from past spills and/or leaks, chlorinated solvents, metals, and polychlorinated biphenyls (PCBs).« less
Behavioral Determinants of Drug Action: The Contributions of Peter B. Dews
ERIC Educational Resources Information Center
Barrett, James E.
2006-01-01
Peter B. Dews played a significant role in shaping the distinctive characteristics and defining the underlying principles of the discipline of behavioral pharmacology. His early and sophisticated use of schedules of reinforcement in the 1950s, incorporated from research in the experimental analysis of behavior and integrated into the discipline of…
USDA-ARS?s Scientific Manuscript database
Muskmelons, both cantaloupe (Cucumis melo Reticulatus Group) and orange-fleshed honey dew (C. melo Inodorus Group), a cross between orange-fleshed cantaloupe and green-fleshed honey dew, are excellent sources of ß-carotene. Although ß-carotene from melon is an important dietary antioxidant and precu...
Design of a diagnostic encyclopaedia using AIDA.
van Ginneken, A M; Smeulders, A W; Jansen, W
1987-01-01
Diagnostic Encyclopaedia Workstation (DEW) is the name of a digital encyclopaedia constructed to contain reference knowledge with respect to the pathology of the ovary. Comparing DEW with the common sources of reference knowledge (i.e. books) leads to the following advantages of DEW: it contains more verbal knowledge, pictures and case histories, and it offers information adjusted to the needs of the user. Based on an analysis of the structure of this reference knowledge we have chosen AIDA to develop a relational database and we use a video-disc player to contain the pictorial part of the database. The system consists of a database input version and a read-only run version. The design of the database input version is discussed. Reference knowledge for ovary pathology requires 1-3 Mbytes of memory. At present 15% of this amount is available. The design of the run version is based on an analysis of which information must necessarily be specified to the system by the user to access a desired item of information. Finally, the use of AIDA in constructing DEW is evaluated.
Dew, fog, drizzle and rain water in Baku (Azerbaijan)
NASA Astrophysics Data System (ADS)
Meunier, D.; Beysens, D.
2016-09-01
Dwindling supplies of fresh water and climate changes have drawn attention to the need to find alternative sources of water globally. This study examines the potential of the semi-arid region of Baku (Azerbaijan) to exploit in particular dew, but also fog, drizzle and rain water. The Absheron Peninsular suffers from scarceness of water and non-hazardous water sources. Measurements were taken in this region on a 30° inclined plane passive condenser over a year (1/4/2010-31/3/2011) to determine the contribution and validity of using these alternative sources of water. The results show a significant relative contribution from these sources during this period (rain: 84 mm; dew: 15 mm; fog: 6 mm; drizzle: 13 mm). The fact that rain was measured within 23 km from the main station leads to uncertainties in its relative contribution. However, at least for the year under study, there are fair indications that collecting dew, fog and drizzle in addition to rain can significantly increase the collected atmospheric water with value estimated on order 40% ± 20%.
NASA Astrophysics Data System (ADS)
Merkushkin, Alexander; Gafurov, Abror; Agaltseva, Natalya; Pak, Alexander; Mannig, Birgit; Paeth, Heiko; Vorogushyn, Sergiy; Unger-Shayesteh, Katy
2014-05-01
Increased frequency of natural hazards under conditions of observed climate change in Uzbekistan has become challenging concern and shows the need to develop more effective climate risk mechanisms towards improving the security of society and sustainable development. In the framework of presented study, the importance of drought monitoring and methodologies for early warning for such purposes in Uzbekistan are demonstrated. For the conditions of Uzbekistan, droughts are most dangerous climate related natural phenomenon. Therefore, the CRM-Uz Project on Climate Risk Management was established with focus on reducing climate risks, strengthening adaptive capacity for stimulating the development of early warning mechanisms, as well as to build up the basis for long-term investments. This serves to increase resilience to climate impacts in the country. In the frame of the CRM-Uz Project, Drought Early Warning System (DEWS), has been developed and implemented in one of the southern provinces of Uzbekistan (Kashkadarya). The main task of DEWS is to provide population with information on the possibility of upcoming drought season in advance. DEWS is used for the assessment, monitoring, prevention, early warning and decision making in this region. Such early warning system provides the required information to undertake appropriate measures against drought and to mitigate its adverse effects to society. It is clear that during years with expected drought the hydrological forecasts become much more important. Complex mathematical model which simulates of run-off formation as a basis of DEWS provides the seasonal hydrological forecasts that are used to inform all concerned sectors, especially the agricultural sector on water availability during the vegetation period. In the frame of cooperation with German Research Centre for Geosciences (GFZ) within the CAWa Project, the DEWS was extended through implementation of MODSNOW - the operational tool for snow cover monitoring at the Drought Monitoring Centre at UzHydromet. The upgrade of the DEWS withMODSNOW strengthens DEWS's capacity in terms of improvement the hydrological forecasting. Moreover, based on climate scenarios provided within the CAWa project by the University of Würzburg, the regional hydrological model AISHF was used to asses medium and long term water availability in the Kashkadarya River which indicates a reduction of water resources in the selected basin in the future.
Method of immobilizing water-soluble bioorganic compounds on a capillary-porous carrier
Ershov, Gennady Moiseevich; Timofeev, Eduard Nikolaevich; Ivanov, Igor Borisovich; Florentiev, Vladimir Leonidovich; Mirzabekov, Andrei Darievich
1998-01-01
The method for immobilizing water-soluble bioorganic compounds to capillary-porous carrier comprises application of solutions of water-soluble bioorganic compounds onto a capillary-porous carrier, setting the carrier temperature equal to or below the dew point of the ambient air, keeping the carrier till appearance of water condensate and complete swelling of the carrier, whereupon the carrier surface is coated with a layer of water-immiscible nonluminescent inert oil and is allowed to stand till completion of the chemical reaction of bonding the bioorganic compounds with the carrier.
Comparisons between Nimbus 6 satellite and rawinsonde soundings for several geographical areas
NASA Technical Reports Server (NTRS)
Cheng, N. M.; Scoggins, J. R.
1981-01-01
Good agreement between satellite and weighted (linearly interpolated) rawinsonde temperature and temperature derived parameters was found in most instances with the poorest agreement either near the tropopause region or near the ground. However, satellite moisture data are highly questionable. The smallest discrepancy between satellite and weighted mean rawinsonde temperature and parameters derived from temperature was found over water and the largest discrepancy was found over mountains. Cumulative frequency distributions show that discrepancies between satellite and rawinsonde data can be represented by a normal distribution except for dew point temperature.
NASA Technical Reports Server (NTRS)
Seshadri, K.; Rosner, D. E.
1985-01-01
An application of an optical polarization technique in a combustion environment is demonstrated by following, in real-time, growth rates of boric oxide condensate on heated platinum ribbons exposed to seeded propane-air combustion gases. The results obtained agree with the results of earlier interference measurements and also with theoretical chemical vapor deposition predictions. In comparison with the interference method, the polarization technique places less stringent requirements on surface quality, which may justify the added optical components needed for such measurements.
Thermoregulatory Responses to Intermittent Exercise Are Influenced by Knit Structure of Underwear
1990-01-01
determined at 120 min, when Swo,(K3) and Swt(K4) were lower compared to both Sw,,(K2) and Swot (K5) 400 (Fig. 3). 300 Skin wettednessEE The knit...dew Pugh LGC (1966) Clothing insulation and accidential hypo- point temperature sensor. J Appl Physiol 52: 1658- 1660 thermia in youth. Nature 209: 1281...insulation. J Appl Physiol 8:539-545 cise and thermal stress. Physiol Rev 54:75-159 Hardy JI), )uBois EF (1938) Basal metabolism, radiation, Saltin B
Water and chemical input via hydrometeors in central European mountains with Szrenica as an example
NASA Astrophysics Data System (ADS)
Błaś, M.; Sobik, M.; Polkowska, Ż.; Cichała-Kamrowska, K.
2010-07-01
Atmospheric pollutants are transferred to the ground by the contribution of various types of hydrometeors. These are atmospheric precipitation and non-precipitation components belonging to the atmospheric deposits (dew and hoarfrost as well as rime and liquid fog). Due to the different techniques concerning sampling and measurements, comparative analyses between them are often neglected. Hence, the main goal is to compare chemistry of different types of hydrometeors and their role in both: water balance and pollutants deposition. Precipitation, dew, hoarfrost, liquid fog and rime samples were collected daily all through the 2009 year at the Szrenica Mt. [1330 m a.s.l.]. It is situated in the western part of the main ridge of the Karkonosze Mts. which falls steeply northward on the Polish side and forms a distinct slope about 1000 m high. During typical westerly wind conditions the Karkonosze Mts. are exposed to highly polluted air from heavy industry densely situated at the distance of tens to hundreds kilometers on the windward side of the mountains. Precipitation is the main source of water flux at the Szrenica Mt. reaching 1430 mm annually, with the highest molar concentrations of ammonia, nitrates and sulphates (33%, 21% and 14% respectively). However the average TIC (Total Inorganic Ionic Content) of precipitation (273 µMoles•l-1) was the lowest when compared with other non-precipitation hydrometeors, discussed below. This results from relatively clean air in middle and/or upper parts of troposphere where atmospheric processes responsible for precipitation formation take place. This is in contrast with much more polluted atmospheric boundary layer being continuously polluted by various emission sources. Fog deposit tends to be the second important component of water flux at the Szrenica Mt., which forms even 50% of water delivered by atmospheric precipitation. Cloud water concentration of dissolved pollutants expressed by TIC was 3 times higher than in case of precipitation (880 µMoles•l 1), with nitrates, ammonia and sulphates as major ions (27%, 26% and 11% respectively). It is due to the more polluted nature of the boundary layer than the free atmosphere, as well as fog water originating in low-level air. That is also the reason why chemical composition of low-level clouds forms an appriopriate indicator of the local and regional scale anthropogenic pollution and for larger scale comparisons of chemical components in cloudy environments. Summarizing, direct pollutant deposition via cloud droplets to vegetation is larger than via precipitation because of much higher pollutant concentration of the former. Dew and hoarfrost provide water quantities much lower to fog or rain, but is a modest supplementary source of water (approximately 0,8% when compare with precipitation). They appear especially during the anticyclonic type of weather with no wind and clear night skies, rare at summit position. TIC for dew and hoarfrost samples was a bit higher in comparison with precipitation (346 µMoles•l-1), but chemical composition quite different to others hydrometeors (chloride - 20%, sodium - 19% and calcium - 18%). It might be explained by air subsidence from the upper part of atmosphere, typical for the mountain summits in anticyclonic type of weather. Stable thermal stratification limits vertical air pollutant transport, especially of anthropogenic origin, and the thickness of the atmospheric mixing layer is visibly lessened. Hence, maritime aerosol is much more important in such circumstances. Both climate and landscape in Poland are similar to major part of central and western Europe so you can expect that relationship between different components of water flux and pollutant deposition observed at the Mt. Szrenica are applicable also to other European countries where similar natural conditions are found.
NASA Technical Reports Server (NTRS)
Orcutt, John M.; Brenton, James C.
2016-01-01
An accurate database of meteorological data is essential for designing any aerospace vehicle and for preparing launch commit criteria. Meteorological instrumentation were recently placed on the three Lightning Protection System (LPS) towers at Kennedy Space Center (KSC) launch complex 39B (LC-39B), which provide a unique meteorological dataset existing at the launch complex over an extensive altitude range. Data records of temperature, dew point, relative humidity, wind speed, and wind direction are produced at 40, 78, 116, and 139 m at each tower. The Marshall Space Flight Center Natural Environments Branch (EV44) received an archive that consists of one-minute averaged measurements for the period of record of January 2011 - April 2015. However, before the received database could be used EV44 needed to remove any erroneous data from within the database through a comprehensive quality control (QC) process. The QC process applied to the LPS towers' meteorological data is similar to other QC processes developed by EV44, which were used in the creation of meteorological databases for other towers at KSC. The QC process utilized in this study has been modified specifically for use with the LPS tower database. The QC process first includes a check of each individual sensor. This check includes removing any unrealistic data and checking the temporal consistency of each variable. Next, data from all three sensors at each height are checked against each other, checked against climatology, and checked for sensors that erroneously report a constant value. Then, a vertical consistency check of each variable at each tower is completed. Last, the upwind sensor at each level is selected to minimize the influence of the towers and other structures at LC-39B on the measurements. The selection process for the upwind sensor implemented a study of tower-induced turbulence. This paper describes in detail the QC process, QC results, and the attributes of the LPS towers meteorological database.
Observations of Lake-Breeze Events During the Toronto 2015 Pan-American Games
NASA Astrophysics Data System (ADS)
Mariani, Zen; Dehghan, Armin; Joe, Paul; Sills, David
2018-01-01
Enhanced meteorological observations were made during the 2015 Pan and Parapan American Games in Toronto in order to measure the vertical and horizontal structure of lake-breeze events. Two scanning Doppler lidars (one fixed and one mobile), a C-band radar, and a network including 53 surface meteorological stations (mesonet) provided pressure, temperature, humidity, and wind speed and direction measurements over Lake Ontario and urban areas. These observations captured the full evolution (prior, during, and after) of 27 lake-breeze events (73% of observation days) in order to characterize the convective and dynamic processes driving lake breezes at the local scale and mesoscale. The dominant signal of a passing lake-breeze front (LBF) was an increase in dew-point temperature of 2.3 ± 0.3°C, coinciding with a 180° shift in wind direction and a decrease in air temperature of 2.1 ± 0.2°C. Doppler lidar observations over the lake detected lake breezes 1 hour (on average) before detection by radar and mesonet. On days with the synoptic flow in the offshore direction, the lidars observed wedge-shaped LBFs with shallow depths, which inhibited the radar's ability to detect the lake breeze. The LBF's ground speed and inland penetration distance were found to be well-correlated (r = 0.78), with larger inland penetration distances occurring on days with non-opposing (non-offshore) synoptic flow. The observed enhanced vertical motion ({>} 1 m s^{-1}) at the LBF, observed by the lidar on 54% of lake-breeze days, was greater (at times {>} 2.5 m s^{-1}) than that observed in previous studies and longer-lasting over the lake than over land. The weaker and less pronounced lake-breeze structure over land is illustrated in two case studies highlighting the lifetime of the lake-breeze circulation and the impact of propagation distance on lake-breeze intensity.
Modeling of Hydrate Formation Mode in Raw Natural Gas Air Coolers
NASA Astrophysics Data System (ADS)
Scherbinin, S. V.; Prakhova, M. Yu; Krasnov, A. N.; Khoroshavina, E. A.
2018-05-01
Air cooling units (ACU) are used at all the gas fields for cooling natural gas after compressing. When using ACUs on raw (wet) gas in a low temperature condition, there is a danger of hydrate plug formation in the heat exchanging tubes of the ACU. To predict possible hydrate formation, a mathematical model of the air cooler thermal behavior used in the control system shall adequately calculate not only gas temperature at the cooler's outlet, but also a dew point value, a temperature at which condensation, as well as the gas hydrate formation point, onsets. This paper proposes a mathematical model allowing one to determine the pressure in the air cooler which makes hydrate formation for a given gas composition possible.
Of Needles and Haystacks: Building an Accurate Statewide Dropout Early Warning System in Wisconsin
ERIC Educational Resources Information Center
Knowles, Jared E.
2015-01-01
The state of Wisconsin has one of the highest four year graduation rates in the nation, but deep disparities among student subgroups remain. To address this the state has created the Wisconsin Dropout Early Warning System (DEWS), a predictive model of student dropout risk for students in grades six through nine. The Wisconsin DEWS is in use…
Dew point temperature affects ascospore release of allergenic genus Leptosphaeria
NASA Astrophysics Data System (ADS)
Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J.; Jedryczka, Malgorzata
2018-06-01
The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.
Dew point temperature affects ascospore release of allergenic genus Leptosphaeria
NASA Astrophysics Data System (ADS)
Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J.; Jedryczka, Malgorzata
2018-01-01
The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.
Dozier, W A; Lott, B D; Branton, S L
2005-08-01
This study examined the effects of varying air velocities vs. a constant air velocity with a cyclic temperature curve of 25-30-25 degrees C and a dew point of 23 degrees C on broilers from 28 to 49 d of age. Four replicate trials were conducted. In each trial, 742 male broilers were randomly allocated to 6 floor pens or 2 air velocity tunnels, with each tunnel consisting of 4 pens. Bird density, feeder, and waterer space were similar across all pens (53 birds/ pen; 0.07 m2/bird). The treatments were control (still air), constant air velocity of 120 m/min, and increasing air velocity (90 m/min from 28 to 35 d, 120 m/min from 36 to 42 d, and 180 m/min from 43 to 49 d). Birds grown in a still air environment gained less weight, consumed less feed, and converted feed less efficiently between 28 and 49 d than birds subjected to moving air (constant or increasing). Growth responses between the air velocity treatments were similar from 28 to 35 and 36 to 42 d of age. Increasing air velocity to 180 m/min improved (P < or = 0.02) the growth rate of broilers from 43 to 49 d of age over birds receiving an air velocity of 120 m/min, but the incidence of mortality was not affected. These results provide evidence that increasing air velocity from 120 to 180 m/min is beneficial to broilers weighing 2.5 kg or greater when exposed to moderate temperatures.
Dew point temperature affects ascospore release of allergenic genus Leptosphaeria.
Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J; Jedryczka, Malgorzata
2018-06-01
The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.
Insights into mountain precipitation and snowpack from a basin-scale wireless-sensor network
NASA Astrophysics Data System (ADS)
Zhang, Z.; Glaser, S.; Bales, R.; Conklin, M.; Rice, R.; Marks, D.
2017-08-01
A spatially distributed wireless-sensor network, installed across the 2154 km2 portion of the 5311 km2 American River basin above 1500 m elevation, provided spatial measurements of temperature, relative humidity, and snow depth in the Sierra Nevada, California. The network consisted of 10 sensor clusters, each with 10 measurement nodes, distributed to capture the variability in topography and vegetation cover. The sensor network captured significant spatial heterogeneity in rain versus snow precipitation for water-year 2014, variability that was not apparent in the more limited operational data. Using daily dew-point temperature to track temporal elevational changes in the rain-snow transition, the amount of snow accumulation at each node was used to estimate the fraction of rain versus snow. This resulted in an underestimate of total precipitation below the 0°C dew-point elevation, which averaged 1730 m across 10 precipitation events, indicating that measuring snow does not capture total precipitation. We suggest blending lower elevation rain gauge data with higher-elevation sensor-node data for each event to estimate total precipitation. Blended estimates were on average 15-30% higher than using either set of measurements alone. Using data from the current operational snow-pillow sites gives even lower estimates of basin-wide precipitation. Given the increasing importance of liquid precipitation in a warming climate, a strategy that blends distributed measurements of both liquid and solid precipitation will provide more accurate basin-wide precipitation estimates, plus spatial and temporal patters of snow accumulation and melt in a basin.
NASA Astrophysics Data System (ADS)
Suresh Babu, K. V.; Roy, Arijit; Ramachandra Prasad, P.
2016-05-01
Forest fire has been regarded as one of the major causes of degradation of Himalayan forests in Uttarakhand. Forest fires occur annually in more than 50% of forests in Uttarakhand state, mostly due to anthropogenic activities and spreads due to moisture conditions and type of forest fuels. Empirical drought indices such as Keetch-Byram drought index, the Nesterov index, Modified Nesterov index, the Zhdanko index which belongs to the cumulative type and the Angstrom Index which belongs to the daily type have been used throughout the world to assess the potential fire danger. In this study, the forest fire danger index has been developed from slightly modified Nesterov index, fuel and anthropogenic activities. Datasets such as MODIS TERRA Land Surface Temperature and emissivity (MOD11A1), MODIS AQUA Atmospheric profile product (MYD07) have been used to determine the dew point temperature and land surface temperature. Precipitation coefficient has been computed from Tropical Rainfall measuring Mission (TRMM) product (3B42RT). Nesterov index has been slightly modified according to the Indian context and computed using land surface temperature, dew point temperature and precipitation coefficient. Fuel type danger index has been derived from forest type map of ISRO based on historical fire location information and disturbance danger index has been derived from disturbance map of ISRO. Finally, forest fire danger index has been developed from the above mentioned indices and MODIS Thermal anomaly product (MOD14) has been used for validating the forest fire danger index.
Atmospheric Pressure and Onset of Episodes of Menière's Disease - A Repeated Measures Study.
Gürkov, Robert; Strobl, Ralf; Heinlin, Nina; Krause, Eike; Olzowy, Bernhard; Koppe, Christina; Grill, Eva
2016-01-01
External changes of air pressure are transmitted to the middle and inner ear and may be used therapeutically in Menière's disease, one of the most common vertigo disorders. We analyzed the possible relationship of atmospheric pressure and other meteorological parameters with the onset of MD vertigo episodes in order to determine whether atmospheric pressure changes play a role in the occurrence of MD episodes. Patients of a tertiary outpatient dizziness clinic diagnosed with MD were asked to keep a daily vertigo diary to document MD episodes (2004-2009). Local air pressure, absolute temperature and dew point temperature were acquired on an hourly basis. Change in meteorological parameters was conceptualized as the maximum difference in a 24 hour time frame preceding each day. Effects were estimated using additive mixed models with a random participant effect. We included lagged air parameters, age, sex, weekday and season in the model. A total of 56 persons (59% female) with mean age 54 years were included. Mean follow-up time was 267 days. Persons experienced on average 10.3 episodes during the observation period (median 8). Age and change in air pressure were significantly associated with vertigo onset risk (Odds Ratio = 0.979 and 1.010). We could not show an effect of sex, weekday, season, air temperature, and dew point temperature. Change in air pressure was significantly associated with onset of MD episodes, suggesting a potential triggering mechanism in the inner ear. MD patients may possibly use air pressure changes as an early warning system for vertigo attacks in the future.
Transported acid aerosols measured in southern Ontario
NASA Astrophysics Data System (ADS)
Keeler, Gerald J.; Spengler, John D.; Koutrakis, Petros; Allen, George A.; Raizenne, Mark; Stern, Bonnie
During the period 29 June 1986-9 August 1986, a field health study assessing the acute health effects of air pollutants on children was conducted at a summer girls' camp on the northern shore of Lake Erie in SW Ontario. Continuous air pollution measurements of SO 2, O 3, NO x, particulate sulfates, light scattering, and meteorological measurements including temperature, dew point, and wind speed and direction were made. Twelve-hour integrated samples of size fractioned particles were also obtained using dichotomous samplers and Harvard impactors equipped with an ammonia denuder for subsequent hydrogen ion determination. Particulate samples were analyzed for trace elements by X-ray fluorescence and Neutron Activation, and for organic and elemental carbon by a thermal/optical technique. The measured aerosol was periodically very acidic with observed 12-h averaged H + concentrations in the range < 10-560 nmoles m -3. The aerosol H + appeared to represent the net strong acidity after H 2SO 4 reaction with NH 3(g). Average daytime concentrations were higher than night-time for aerosol H +, sulfate, fine mass and ozone. Prolonged episodes of atmospheric acidity, sulfate, and ozone were associated with air masses arriving at the measurement site from the west and from the southwest over Lake Erie. Sulfate concentrations measured at the lakeshore camp were more than twice those measured at inland sites during extreme pollution episodes. The concentration gradient observed with onshore flow was potentially due to enhanced deposition near the lakeshore caused by discontinuities in the meteorological fields in this region.
Tiwari, Akhilesh; Kondjoyan, Alain; Fontaine, Jean-Pierre
2012-07-01
The phenomenon of heat and mass transfer by condensation of water vapour from humid air involves several key concepts in aerobic bioreactors. The high performance of bioreactors results from optimised interactions between biological processes and multiphase heat and mass transfer. Indeed in various processes such as submerged fermenters and solid-state fermenters, gas/liquid transfer need to be well controlled, as it is involved at the microorganism interface and for the control of the global process. For the theoretical prediction of such phenomena, mathematical models require heat and mass transfer coefficients. To date, very few data have been validated concerning mass transfer coefficients from humid air inflows relevant to those bioprocesses. Our study focussed on the condensation process of water vapour and developed an experimental set-up and protocol to study the velocity profiles and the mass flux on a small size horizontal flat plate in controlled environmental conditions. A closed circuit wind tunnel facility was used to control the temperature, hygrometry and hydrodynamics of the flow. The temperature of the active surface was controlled and kept isothermal below the dew point to induce condensation, by the use of thermoelectricity. The experiments were performed at ambient temperature for a relative humidity between 35-65% and for a velocity of 1.0 ms⁻¹. The obtained data are analysed and compared to available theoretical calculations on condensation mass flux.
In situ Micrometeorological Measurements during RxCADRE
NASA Astrophysics Data System (ADS)
Clements, C. B.; Hiers, J. K.; Strenfel, S. J.
2009-12-01
The Prescribed Fire Combustion and Atmospheric Dynamics Research Experiment (RxCADRE) was a collaborative research project designed to fully instrument prescribed fires in the Southeastern United States. Data were collected on pre-burn fuel loads, post burn consumption, ambient weather, in situ atmospheric dynamics, plume dynamics, radiant heat release (both from in-situ and remote sensors), in-situ fire behavior, and select fire effects. The sampling was conducted at Eglin Air Force Base, Florida, and the Joseph W. Jones Ecological Research Center in Newton, Georgia, from February 29 to March 6, 2008. Data were collected on 5 prescribed burns, totaling 4458 acres. The largest aerial ignition totaled 2,290 acres and the smallest ground ignition totaled 104 acres. Quantifying fire-atmospheric interactions is critical for understanding wildland fire dynamics and enhancing modeling of smoke plumes. During Rx-CADRE, atmospheric soundings using radiosondes were made at each burn prior to ignition. In situ micrometeorological measurements were made within each burn unit using five portable, 10-m towers equipped with sonic and prop anemometers, fine-wire thermocouples, and a carbon dioxide probes. The towers were arranged within the burn units to capture the wind and temperature fields as the fire front and plume passed the towers. Due to the interaction of fire lines following ignition, several of the fire fronts that passed the towers were backing fires and thus less intense. Preliminary results indicate that the average vertical velocities associated with the fire front passage were on the order of 3-5 m s-1 and average plume temperatures were on the order of 30-50 °C above ambient. During two of the experimental burns, radiosondes were released into the fire plumes to determine the vertical structure of the plume temperature, humidity, and winds. A radiosonde released into the plume during the burn conducted on 3 March 2008 indicated a definite plume boundary in the potential temperature and dew point temperature structure. The plume height immediately downwind of the fire front was approximately 150 m AGL and heating within this layer was on the order of 3 K. One interesting feature of the plume was the enhanced wind velocity at the top of the plume. Winds increased by 2 m s-1 in a shallow layer at the very top of the plume boundary indicating enhanced acceleration due to the increase in buoyancy. This experience highlights the dynamism of interacting fire lines within prescribed burns as well as the difficulty of measuring fire-atmospheric interactions on large prescribed fire ignitions.
ERIC Educational Resources Information Center
Clune, Bill; Knowles, Jared
2016-01-01
Since 2012, the Wisconsin Department of Public Instruction (DPI) has maintained a statewide predictive analytics system providing schools with an early warning in middle grades of students at risk for not completing high school. DPI is considering extending and enhancing this system, known as the Dropout Early Warning System (DEWS). The proposed…
Activities in Cu2S-FeS-PbS melts at 1200 °C
NASA Astrophysics Data System (ADS)
Eriç, H.; Timuçin, M.
1981-09-01
The dew-point method was used to determine the vapor pressures of PbS over liquid sulfides of the system Cu2S-FeS-PbS at 1200 °C. From the PbS activity data, activities of Cu2S and FeS were evaluated both in binary and ternary melts by Gibbs-Duhem calculations. The systems Cu2S-PbS and Cu2S-FeS exhibit negative departures from ideal behavior, while the FeS-PbS melts are ideal solutions at 1200 °C.
Performance characterization of a Bosch CO sub 2 reduction subsystem
NASA Technical Reports Server (NTRS)
Heppner, D. B.; Hallick, T. M.; Schubert, F. H.
1980-01-01
The performance of Bosch hardware at the subsystem level (up to five-person capacity) in terms of five operating parameters was investigated. The five parameters were: (1) reactor temperature, (2) recycle loop mass flow rate, (3) recycle loop gas composition (percent hydrogen), (4) recycle loop dew point and (5) catalyst density. Experiments were designed and conducted in which the five operating parameters were varied and Bosch performance recorded. A total of 12 carbon collection cartridges provided over approximately 250 hours of operating time. Generally, one cartridge was used for each parameter that was varied. The Bosch hardware was found to perform reliably and reproducibly. No startup, reaction initiation or carbon containment problems were observed. Optimum performance points/ranges were identified for the five parameters investigated. The performance curves agreed with theoretical projections.
Seo, Donghyun; Lee, Junghun; Lee, Choongyeop; Nam, Youngsuk
2016-01-01
The efficient water harvesting from air-laden moisture has been a subject of great interest to address world-wide water shortage issues. Recently, it has been shown that tailoring surface wettability can enhance the moisture harvesting performance. However, depending on the harvesting condition, a different conclusion has often been reported and it remains unclear what type of surface wettability would be desirable for the efficient water harvesting under the given condition. Here we compare the water harvesting performance of the surfaces with various wettability under two different harvesting conditions–dewing and fogging, and show that the different harvesting efficiency of each surface under these two conditions can be understood by considering the relative importance of the water capturing and removal efficiency of the surface. At fogging, the moisture harvesting performance is determined by the water removal efficiency of the surface with the oil-infused surfaces exhibiting the best performance. Meanwhile, at dewing, both the water capturing and removal efficiency are crucial to the harvesting performance. And well-wetting surfaces with a lower barrier to nucleation of condensates exhibit a better harvesting performance due to the increasing importance of the water capture efficiency over the water removal efficiency at dewing. PMID:27063149
Akinbode, O M; Eludoyin, A O; Fashae, O A
2008-04-01
This study was carried out in one of the medium-sized public administrative towns in the southwestern part of Nigeria. Its aim is to highlight the effect of spatial distribution of settlements, population, and socio-economic activities on urban air temperature and humidity in the town. Temperature and relative humidity data from 1992 to 2001 were obtained from three meteorological stations in Akure, the Administrative Capital of Ondo State, Nigeria. The stations are located within the Federal Ministry of Aviation, Akure Airport (FMA), Federal University of Technology, Akure (FUTA) and Federal School of Agriculture (SOA). Air temperature and relative humidity measurements were also obtained from 27 points, which were cited to include road junctions, markets, built up areas, etc., using sling psychrometer. The data were subsequently analysed for spatial and temporal variations using statistical packages (SPSS and Microsoft Excel) and isolines. Actual vapour pressure and dew point temperature were computed using Magnus conversion formulae. The results obtained showed that spatial variation was insignificant, in terms of the temperature and humidity variables. The annual mean temperature (Tmean) ranged between 21.9 and 30.4 degrees C while minimum (Tmin) and maximum (Tmax) temperatures varied from 13 to 26 and 21.5-39.6 degrees C, respectively. Relative humidity (RH), actual vapour pressure (Es) and dew point temperature (Td) values also varied from 39.1% to 98.2%, 19.7-20.8 gm(-3), and 17.3-17.8 degrees C, respectively. A significant relationship (p>0.6; r<0.05) between Tmin, Es and Td was observed while the daytime 'urban heat island' intensity (UHI) ranged between 0.5 and 2.5 degrees C within the study period. The study concluded that there is influence of urban canopy on the microclimate of Akure, and hypothesizes that the urban dwellers may be subjected to some levels of weather related physiological disorderliness.
DISTANT EARLY WARNING SYSTEM for Tsunamis - A wide-area and multi-hazard approach
NASA Astrophysics Data System (ADS)
Hammitzsch, Martin; Lendholt, Matthias; Wächter, Joachim
2010-05-01
The DEWS (Distant Early Warning System) [1] project, funded under the 6th Framework Programme of the European Union, has the objective to create a new generation of interoperable early warning systems based on an open sensor platform. This platform integrates OGC [2] SWE [3] compliant sensor systems for the rapid detection of hazardous events, like earthquakes, sea level anomalies, ocean floor occurrences, and ground displacements in the case of tsunami early warning. Based on the upstream information flow DEWS focuses on the improvement of downstream capacities of warning centres especially by improving information logistics for effective and targeted warning message aggregation for a multilingual environment. Multiple telecommunication channels will be used for the dissemination of warning messages. Wherever possible, existing standards have been integrated. The Command and Control User Interface (CCUI), a rich client application based on Eclipse RCP (Rich Client Platform) [4] and the open source GIS uDig [5], integrates various OGC services. Using WMS (Web Map Service) [6] and WFS (Web Feature Service) [7] spatial data are utilized to depict the situation picture and to integrate a simulation system via WPS (Web Processing Service) [8] to identify affected areas. Warning messages are compiled and transmitted in the OASIS [9] CAP (Common Alerting Protocol) [10] standard together with addressing information defined via EDXL-DE (Emergency Data Exchange Language - Distribution Element) [11]. Internal interfaces are realized with SOAP [12] web services. Based on results of GITEWS [13] - in particular the GITEWS Tsunami Service Bus [14] - the DEWS approach provides an implementation for tsunami early warning systems but other geological paradigms are going to follow, e.g. volcanic eruptions or landslides. Therefore in future also multi-hazard functionality is conceivable. The specific software architecture of DEWS makes it possible to dock varying sensors to the system and to extend the CCUI with hazard specific functionality. The presentation covers the DEWS project, the system architecture and the CCUI in conjunction with details of information logistics. The DEWS Wide Area Centre connecting national centres to allow the international communication and warning exchange is presented also. REFERENCES: [1] DEWS, www.dews-online.org [2] OGC, www.opengeospatial.org [3] SWE, www.opengeospatial.org/projects/groups/sensorweb [4] Eclipse RCP, www.eclipse.org/home/categories/rcp.php [5] uDig, udig.refractions.net [6] WMS, www.opengeospatial.org/standards/wms [7] WFS, www.opengeospatial.org/standards/wfs [8] WPS, www.opengeospatial.org/standards/wps [9] OASIS, www.oasis-open.org [10] CAP, www.oasis-open.org/specs/#capv1.1 [11] EDXL-DE, www.oasis-open.org/specs/#edxlde-v1.0 [12] SOAP, www.w3.org/TR/soap [13] GITEWS (German Indonesian Tsunami Early Warning System) is a project of the German Federal Government to aid the recon¬struction of the tsunami-prone Indian Ocean region, www.gitews.org [14] The Tsunami Service Bus is the GITEWS sensor system integration platform offering standardised services for the detection and monitoring of tsunamis
Spatiotemporal exposure modeling of ambient erythemal ultraviolet radiation.
VoPham, Trang; Hart, Jaime E; Bertrand, Kimberly A; Sun, Zhibin; Tamimi, Rulla M; Laden, Francine
2016-11-24
Ultraviolet B (UV-B) radiation plays a multifaceted role in human health, inducing DNA damage and representing the primary source of vitamin D for most humans; however, current U.S. UV exposure models are limited in spatial, temporal, and/or spectral resolution. Area-to-point (ATP) residual kriging is a geostatistical method that can be used to create a spatiotemporal exposure model by downscaling from an area- to point-level spatial resolution using fine-scale ancillary data. A stratified ATP residual kriging approach was used to predict average July noon-time erythemal UV (UV Ery ) (mW/m 2 ) biennially from 1998 to 2012 by downscaling National Aeronautics and Space Administration (NASA) Total Ozone Mapping Spectrometer (TOMS) and Ozone Monitoring Instrument (OMI) gridded remote sensing images to a 1 km spatial resolution. Ancillary data were incorporated in random intercept linear mixed-effects regression models. Modeling was performed separately within nine U.S. regions to satisfy stationarity and account for locally varying associations between UV Ery and predictors. Cross-validation was used to compare ATP residual kriging models and NASA grids to UV-B Monitoring and Research Program (UVMRP) measurements (gold standard). Predictors included in the final regional models included surface albedo, aerosol optical depth (AOD), cloud cover, dew point, elevation, latitude, ozone, surface incoming shortwave flux, sulfur dioxide (SO 2 ), year, and interactions between year and surface albedo, AOD, cloud cover, dew point, elevation, latitude, and SO 2 . ATP residual kriging models more accurately estimated UV Ery at UVMRP monitoring stations on average compared to NASA grids across the contiguous U.S. (average mean absolute error [MAE] for ATP, NASA: 15.8, 20.3; average root mean square error [RMSE]: 21.3, 25.5). ATP residual kriging was associated with positive percent relative improvements in MAE (0.6-31.5%) and RMSE (3.6-29.4%) across all regions compared to NASA grids. ATP residual kriging incorporating fine-scale spatial predictors can provide more accurate, high-resolution UV Ery estimates compared to using NASA grids and can be used in epidemiologic studies examining the health effects of ambient UV.
Energy Balance, Evapo-transpiration and Dew deposition in the Dead Sea Valley
NASA Astrophysics Data System (ADS)
Metzger, Jutta; Corsmeier, Ulrich
2016-04-01
The Dead Sea is a unique place on earth. It is a terminal hypersaline lake, located at the lowest point on earth with a lake level of currently -429 m above mean sea level (amsl). It is located in a transition zone of semiarid to arid climate conditions, which makes it highly sensible to climate change (Alpert1997, Smiatek2011). The Virtual Institute DEad SEa Research Venue (DESERVE) is an international project funded by the German Helmholtz Association and was established to study coupled atmospheric hydrological, and lithospheric processes in the changing environment of the Dead Sea. At the moment the most prominent environmental change is the lake level decline of approximately 1 m / year due to anthropogenic interferences (Gertman, 2002). This leads to noticeable changes in the fractions of the existing terrestrial surfaces - water, bare soil and vegetated areas - in the valley. Thus, the partitioning of the net radiation in the valley changes as well. To thoroughly study the atmospheric and hydrological processes in the Dead Sea valley, which are driven by the energy balance components, sound data of the energy fluxes of the different surfaces are necessary. Before DESERVE no long-term monitoring network simultaneously measuring the energy balance components of the different surfaces in the Dead Sea valley was available. Therefore, three energy balance stations were installed at three characteristic sites at the coast-line, over bare soil, and within vegetation, measuring all energy balance components by using the eddy covariance method. The results show, that the partitioning of the energy into sensible and latent heat flux on a diurnal scale is totally different at the three sites. This results in gradients between the sites, which are e.g. responsible for the typical diurnal wind systems at the Dead Sea. Furthermore, driving forces of evapo-transpiration at the sites were identified and a detailed analysis of the daily evaporation and dew deposition rates for a whole annual cycle will be presented. Alpert, P., Shafir, H., & Issahary, D. (1997). Recent changes in the climate at the Dead Sea-a preliminary study. Climatic Change, 37(3), 513-537. Gertman, I., & Hecht, A. (2002). The Dead Sea hydrography from 1992 to 2000. Journal of marine systems, 35(3), 169-181. Smiatek, G., Kunstmann, H., & Heckl, A. (2011). High-resolution climate change simulations for the Jordan River area. Journal of Geophysical Research: Atmospheres (1984-2012), 116(D16).
Validation of snow line estimations using MODIS images for the Elqui River basin, Chile
NASA Astrophysics Data System (ADS)
Vasquez, Nicolas; Lagos, Miguel; Vargas, Ximena
2015-04-01
Precipitation events in North-Central Chile are very important because the region has a Mediterranean climate, with a humid period, and an extensive dry one. Separation between solid and liquid precipitation (snow line) in each event is important information that allow to estimate 1) the available snow covered area for snow-melt forecasting, during the dry season (the only resource of water in this period) and 2) the area affected by rain for flood modelling and infrastructure design. In this work, snow line was estimated with a meteorological approach, considering precipitation, temperature, relative humidity and dew point information at a daily scale from 2004 to 2010 and hourly from 2010 to 2013. In both periods, different meteorological stations are considered due to the implementation of new stations in the study area, covering from 1000 to 3000 (m.a.s.l) approximately, with snow and rain meteorological stations. The methodology exposed in this research is based in vertical variation of dew point and temperature due to more stability variations compared to vertical relative humidity behavior. The results calculated from meteorological data are compared with MODIS images, considering three criteria: (1) the median altitude of the minimum specific fractional snow covered area (FSCA), (2) the mean elevation of pixels with a FSCA<10% and (3) the snow line estimation via snow covered area and hypsometric curve. Historically in Chile, snow line has been studied considering few specific precipitation and temperature observations, or estimations of zero isotherms from upper air soundings. A comparison between these estimations and the results validated through MOD10A1/MYD10A1 products was made in order to identify tendencies and/or variations of the snow line at an annually scale.
Climatology of winter transition days for the contiguous USA, 1951-2007
NASA Astrophysics Data System (ADS)
Hondula, David M.; Davis, Robert E.
2011-01-01
In middle and high latitudes, climate change could impact the frequency and characteristics of frontal passages. Although transitions between air masses are significant features of the general circulation that influence human activities and other surface processes, they are much more difficult to objectively identify than single variables like temperature or even extreme events like fires, droughts, and floods. The recently developed Spatial Synoptic Classification (SSC) provides a fairly objective means of identifying frontal passages. In this research, we determine the specific meteorological patterns represented by the SSC's Transition category, a "catch-all" group that attempts to identify those days that cannot be characterized as a single, homogeneous air mass type. The result is a detailed transition climatology for the continental USA. We identify four subtypes of the Transition category based on intra-day sea level pressure change and dew point temperature change. Across the contiguous USA, most transition days are identified as cold fronts and warm fronts during the winter season. Among the two less common subtypes, transition days in which the dew point temperature and pressure both rise are more frequently observed across the western states, and days in which both variables fall are more frequently observed in coastal regions. The relative frequencies of wintertime warm and cold fronts have changed over the period 1951-2007. Relative cold front frequency has significantly increased in the Northeast and Midwest regions, and warm front frequencies have declined in the Midwest, Rocky Mountain, and Pacific Northwest regions. The overall shift toward cold fronts and away from warm fronts across the northern USA arises from a combination of an enhanced ridge over western North America and a northward shift of storm tracks throughout the mid-latitudes. These results are consistent with projections of climate change associated with elevated greenhouse gas concentrations.
Nguyen, Jennifer L.; Dockery, Douglas W.
2015-01-01
The health consequences of heat and cold are usually evaluated based on associations with outdoor measurements at the nearest weather reporting station. However, people in the developed world spend little time outdoors, especially during extreme temperature events. We examined the association between indoor and outdoor temperature and humidity in a range of climates. We measured indoor temperature, apparent temperature, relative humidity, dew point, and specific humidity (a measure of moisture content in air) for one calendar year (2012) in a convenience sample of eight diverse locations ranging from the equatorial region (10°N) to the Arctic (64°N). We then compared the indoor conditions to outdoor values recorded at the nearest airport weather station. We found that the shape of the indoor-to-outdoor temperature and humidity relationships varied across seasons and locations. Indoor temperatures showed little variation across season and location. There was large variation in indoor relative humidity between seasons and between locations which was independent of outdoor, airport measurements. On the other hand, indoor specific humidity, and to a lesser extent dew point, tracked with outdoor, airport measurements both seasonally and between climates, across a wide range of outdoor temperatures. Our results suggest that, depending on the measure, season, and location, outdoor weather measurements can be reliably used to represent indoor exposures and that, in general, outdoor measures of actual moisture content in air better capture indoor exposure than temperature and relative humidity. Therefore, absolute measures of water vapor should be examined in conjunction with other measures (e.g. temperature, relative humidity) in studies of the effect of weather and climate on human health. PMID:26054827
Soverow, Jonathan E.; Wellenius, Gregory A.; Fisman, David N.; Mittleman, Murray A.
2009-01-01
Background The effects of weather on West Nile virus (WNV) mosquito populations in the United States have been widely reported, but few studies assess their overall impact on transmission to humans. Objectives We investigated meteorologic conditions associated with reported human WNV cases in the United States. Methods We conducted a case–crossover study to assess 16,298 human WNV cases reported to the Centers for Disease Control and Prevention from 2001 to 2005. The primary outcome measures were the incidence rate ratio of disease occurrence associated with mean weekly maximum temperature, cumulative weekly temperature, mean weekly dew point temperature, cumulative weekly precipitation, and the presence of ≥ 1 day of heavy rainfall (≥ 50 mm) during the month prior to symptom onset. Results Increasing weekly maximum temperature and weekly cumulative temperature were similarly and significantly associated with a 35–83% higher incidence of reported WNV infection over the next month. An increase in mean weekly dew point temperature was significantly associated with a 9–38% higher incidence over the subsequent 3 weeks. The presence of at least 1 day of heavy rainfall within a week was associated with a 29–66% higher incidence during the same week and over the subsequent 2 weeks. A 20-mm increase in cumulative weekly precipitation was significantly associated with a 4–8% increase in incidence of reported WNV infection over the subsequent 2 weeks. Conclusions Warmer temperatures, elevated humidity, and heavy precipitation increased the rate of human WNV infection in the United States independent of season and each others’ effects. PMID:19654911
Wichansky, P.S.; Steyaert, L.T.; Walko, R.L.; Waever, C.P.
2008-01-01
The 19th-century agrarian landscape of New Jersey (NJ) and the surrounding region has been extensively transformed to the present-day land cover by urbanization, reforestation, and localized areas of deforestation. This study used a mesoscale atmospheric numerical model to investigate the sensitivity of the warm season climate of NJ to these land cover changes. Reconstructed 1880s-era and present-day land cover data sets were used as surface boundary conditions for a set of simulations performed with the Regional Atmospheric Modeling System (RAMS). Three-member ensembles with historical and present-day land cover were compared to examine the sensitivity of surface air and dew point temperatures, rainfall, and the individual components of the surface energy budget to these land cover changes. Mean temperatures for the present-day landscape were 0.3-0.6??C warmer than for the historical landscape over a considerable portion of NJ and the surrounding region, with daily maximum temperatures at least 1.0??C warmer over some of the highly urbanized locations. Reforested regions, however, were slightly cooler. Dew point temperatures decreased by 0.3-0.6??C, suggesting drier, less humid near-surface air for the present-day landscape. Surface warming was generally associated with repartitioning of net radiation from latent to sensible heat flux, and conversely for cooling. While urbanization was accompanied by strong surface albedo decreases and increases in net shortwave radiation, reforestation and potential changes in forest composition have generally increased albedos and also enhanced landscape heterogeneity. The increased deciduousness of forests may have further reduced net downward longwave radiation. Copyright 2008 by the American Geophysical Union.
Schwartz, Bryan G; Qualls, Clifford; Kloner, Robert A; Laskey, Warren K
2015-10-15
A distinct seasonal pattern in total and cardiovascular death rates has been reported. The factors contributing to this pattern have not been fully explored. Seven locations (average total population 71,354,000) were selected where data were available including relatively warm, cold, and moderate temperatures. Over the period 2004 to 2009, there were 2,526,123 all-cause deaths, 838,264 circulatory deaths, 255,273 coronary heart disease deaths, and 135,801 ST-elevation myocardial infarction (STEMI) deaths. We used time series and multivariate regression modeling to explore the association between death rates and climatic factors (temperature, dew point, precipitation, barometric pressure), influenza levels, air pollution levels, hours of daylight, and day of week. Average seasonal patterns for all-cause and cardiovascular deaths were very similar across the 7 locations despite differences in climate. After adjusting for multiple covariates and potential confounders, there was a 0.49% increase in all-cause death rate for every 1°C decrease. In general, all-cause, circulatory, coronary heart disease and STEMI death rates increased linearly with decreasing temperatures. The temperature effect varied by location, including temperature's linear slope, cubic fit, positional shift on the temperature axis, and the presence of circulatory death increases in locally hot temperatures. The variable effect of temperature by location suggests that people acclimatize to local temperature cycles. All-cause and circulatory death rates also demonstrated sizable associations with influenza levels, dew point temperature, and barometric pressure. A greater understanding of how climate, temperature, and barometric pressure influence cardiovascular responses would enhance our understanding of circulatory and STEMI deaths. Copyright © 2015 Elsevier Inc. All rights reserved.
Munksgaard, Niels C; Cheesman, Alexander W; Gray-Spence, Andrew; Cernusak, Lucas A; Bird, Michael I
2018-06-30
Continuous measurement of stable O and H isotope compositions in water vapour requires automated calibration for remote field deployments. We developed a new low-cost device for calibration of both water vapour mole fraction and isotope composition. We coupled a commercially available dew point generator (DPG) to a laser spectrometer and developed hardware for water and air handling along with software for automated operation and data processing. We characterised isotopic fractionation in the DPG, conducted a field test and assessed the influence of critical parameters on the performance of the device. An analysis time of 1 hour was sufficient to achieve memory-free analysis of two water vapour standards and the δ 18 O and δ 2 H values were found to be independent of water vapour concentration over a range of ≈20,000-33,000 ppm. The reproducibility of the standard vapours over a 10-day period was better than 0.14 ‰ and 0.75 ‰ for δ 18 O and δ 2 H values, respectively (1 σ, n = 11) prior to drift correction and calibration. The analytical accuracy was confirmed by the analysis of a third independent vapour standard. The DPG distillation process requires that isotope calibration takes account of DPG temperature, analysis time, injected water volume and air flow rate. The automated calibration system provides high accuracy and precision and is a robust, cost-effective option for long-term field measurements of water vapour isotopes. The necessary modifications to the DPG are minor and easily reversible. Copyright © 2018 John Wiley & Sons, Ltd.
Dew point effect of cooled hydrogel pads on human stratum corneum biosurface.
Xhauflaire-Uhoda, Emmanuelle; Paquet, Philippe; Piérard, Gérald E
2008-01-01
Cooled hydrogel pads are used to prevent overheating effects of laser therapy. They do not induce cold injuries to the skin, but their more subtle physiological effects have not been thoroughly studied. To describe the changes in transepidermal water loss and electrometric properties of the skin surface following application of cooled hydrogel pads. Measurements were performed on normal forearm skin of 27 healthy volunteers and on freshly excised skin from abdominoplasty. LaserAid hydrogel pads cooled to 4 degrees C were placed for 15 min on the forearm skin. Measurements of transepidermal water loss (TEWL) and electrometric properties (Corneometer, Nova DPM 900) were performed before application and after removal of the cooled pads. A consistent increase in corneometer units, dermal phase meter (DPM) values and TEWL were recorded at removal of the cooled hydrogel pads. Both the in vivo and in vitro assessments brought similar information. The similar changes disclosed in vitro and in vivo suggest that a common physical process is operating in these conditions. The observed phenomenon is opposite to the predicted events given by the Arrhenius law probably because of the combination of cooling and occlusion by the pads. A dew point effect (air temperature at which relative humidity is maximal) is likely involved in the moisture content of the stratum corneum. Thus, the biological impact of using cooling hydrogel pads during laser therapy is different from the effect of a cryogenic spray cooling procedure. The better preservation of the water balance in the stratum corneum by the cooled hydrogel pads could have a beneficial esthetic effect on laser treated areas. (c) 2008 S. Karger AG, Basel.
Atmospheric Pressure and Onset of Episodes of Menière’s Disease - A Repeated Measures Study
Strobl, Ralf; Heinlin, Nina; Krause, Eike; Olzowy, Bernhard; Koppe, Christina; Grill, Eva
2016-01-01
Background External changes of air pressure are transmitted to the middle and inner ear and may be used therapeutically in Menière’s disease, one of the most common vertigo disorders. We analyzed the possible relationship of atmospheric pressure and other meteorological parameters with the onset of MD vertigo episodes in order to determine whether atmospheric pressure changes play a role in the occurrence of MD episodes. Methods Patients of a tertiary outpatient dizziness clinic diagnosed with MD were asked to keep a daily vertigo diary to document MD episodes (2004–2009). Local air pressure, absolute temperature and dew point temperature were acquired on an hourly basis. Change in meteorological parameters was conceptualized as the maximum difference in a 24 hour time frame preceding each day. Effects were estimated using additive mixed models with a random participant effect. We included lagged air parameters, age, sex, weekday and season in the model. Results A total of 56 persons (59% female) with mean age 54 years were included. Mean follow-up time was 267 days. Persons experienced on average 10.3 episodes during the observation period (median 8). Age and change in air pressure were significantly associated with vertigo onset risk (Odds Ratio = 0.979 and 1.010). We could not show an effect of sex, weekday, season, air temperature, and dew point temperature. Conclusions Change in air pressure was significantly associated with onset of MD episodes, suggesting a potential triggering mechanism in the inner ear. MD patients may possibly use air pressure changes as an early warning system for vertigo attacks in the future. PMID:27096752
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qu, Ming; Abdelaziz, Omar; Yin, Hongxi
2014-11-01
Conventional natural gas-fired boilers exhaust flue gas direct to the atmosphere at 150 200 C, which, at such temperatures, contains large amount of energy and results in relatively low thermal efficiency ranging from 70% to 80%. Although condensing boilers for recovering the heat in the flue gas have been developed over the past 40 years, their present market share is still less than 25%. The major reason for this relatively slow acceptance is the limited improvement in the thermal efficiency of condensing boilers. In the condensing boiler, the temperature of the hot water return at the range of 50 60more » C, which is used to cool the flue gas, is very close to the dew point of the water vapor in the flue gas. Therefore, the latent heat, the majority of the waste heat in the flue gas, which is contained in the water vapor, cannot be recovered. This paper presents a new approach to improve boiler thermal efficiency by integrating absorption heat pumps with natural gas boilers for waste heat recovery (HRAHP). Three configurations of HRAHPs are introduced and discussed. The three configurations are modeled in detail to illustrate the significant thermal efficiency improvement they attain. Further, for conceptual proof and validation, an existing hot water-driven absorption chiller is operated as a heat pump at operating conditions similar to one of the devised configurations. An overall system performance and economic analysis are provided for decision-making and as evidence of the potential benefits. These three configurations of HRAHP provide a pathway to achieving realistic high-efficiency natural gas boilers for applications with process fluid return temperatures higher than or close to the dew point of the water vapor in the flue gas.« less
A gas sampling system for withdrawing humid gases from deep boreholes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rousseau, J.P.; Thordarson, W.; Kurzmack, M.A.
A gas sampling system, designed to withdraw nearly vapor-saturated gases (93 to 100% relative humidity) from deep, unsaturated zone boreholes, was developed by the U.S. Geological Survey for use in the unsaturated zone borehole instrumentation and monitoring program at Yucca Mountain, Nye County, Nevada. This gas sampling system will be used to: (1) sample formation rock gases in support of the unsaturated zone hydrochemical characterization program; and (2) verify downhole, thermocouple psychrometer measurements of water potential in support of the unsaturated zone borehole instrumentation and monitoring program. Using this sampling system, nearly vapor-saturated formation rock-gases can be withdrawn from deepmore » boreholes without condensing water vapor in the sampling tubes, and fractionating heavy isotopes of oxygen, hydrogen, and carbon. The sampling system described in this paper uses a dry carrier-gas (nitrogen) to lower the dew point temperature of the formation rock-gas at its source. Mixing of the dry carrier gas with the source gas takes place inside a specially designed downhole instrument station apparatus (DISA). Nitrogen inflow is regulated in a manner that lowers the dew point temperature of the source gas to a temperature that is colder than the coldest temperature that the mixed gas will experience in moving from warmer, deeper depths, to colder, shallower depths near the land surface. A test of this gas sampling system was conducted in December, 1992, in a 12.2 meter deep borehole that was instrumented in October, 1991. The water potential calculated using this system reproduced in-situ measurements of water potential to within five percent of the average value, as recorded by two thermocouple psychrometers that had been in operation for over 12 months.« less
Rotorcraft Design for Operations Held in Amsterdam, Netherlands on 13-16 October 1986
1987-06-01
absorber SAfuoptiale - flexible gearbox attachment devices Westland - Westland vibration absorber blo - noodle beam ty don’t they ait together, figau out...onboard data reduction. This permits instant after flight status indication of each module without the need for further processing of data on the...tonctions qui no peuvent prendre dew’ velours ou dew’ modes diff~rents & un instant donnA. a) Wolctiost do 1clichello does distances NAV Ceras commando permit
Magnetic Insulation in Coaxial Transmission Lines with an External Magnetic Field
1980-03-13
A. Mostrom, Michael E. Jones, and Lester E. Thode SUBMITTED TO: Physical Review Letters March 13, 1980 SöKOK_Kä^MJ!L;; ÄgEie?©d tea gas &c...Number Assigned by Contract Monitor: SLL 81- 262 Comments on Document: Archive, RRI, DEW . From Physical Review Letters Descriptors, Keywords: Magnetic...Source of Document: DEW MAGNETIC INSULATION IN COAXIAL TRANSMISSION LINES WITH AN EXTERNAL MAGNETIC FIELD Michael A. Mostrom, Michael E. Jones, and
Interactions involving ozone, Botrytis cinerea, and B. squamosa on onion leaves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rist, D.L.
1983-01-01
Interactions involving Botrytis cinerea Pers., B. squamosa Walker, and ozone on onion (alium cepae L.) were investigated. Initially, threshold dosages of ozone required to predispose onion leaves to greater infection by B. cinerea and B. squamosa were determined under controlled conditions in an ozone-exposure chamber. Subsequent experiments supported the hypothesis that nutrients leaking out of ozone-injured cells stimulated lesion production by B. cinerea. The electrical conductivity of, and carbohydrate concentration in, dew collected from leaves of onion plants which had been exposed to ozone were greater than the electrical conductivity of, and carbohydrate concentration in, dew collected from leaves ofmore » other, non-exposed onion plants. When conidia of B. cinerea were suspended in dew collected from leaves of plants which had been exposed to ozone and the resulting suspension atomized onto leaves of non-exposed plants, more lesions were induced than on leaves of other non-exposed plants inoculated with conidia suspended in dew collected from plants which had not been exposed to ozone. EDU protected onion leaves from ozone-induced predisposition to these fungi under controlled conditions. Experiments designed to detect interaction between B. cinerea and B. squamosa in onion leaf blighting indicated that such interaction did not occur. Leaves were blighted rapidly when inoculated with B. squamosa whether B. cinerea was present or absent.« less
NASA Technical Reports Server (NTRS)
Bauman, William H., III; Flinn, Clay
2012-01-01
Launch directors need to know upper-level wind forecasts. We developed an Excel-based GUI to display upper-level winds: (1) Rawinsonde at CCAFS, (2) Wind profilers at KSC, (3) Model point data at CCAFS.
Digital Earth Watch And Picture Post Network: Measuring The Environment Through Digital Images
NASA Astrophysics Data System (ADS)
Schloss, A. L.; Beaudry, J.; Carrera, F.; Pickle, J.
2010-12-01
Digital Earth Watch (DEW) involves individuals, schools, organizations and communities in a systematic monitoring project of their local environment, especially vegetation health. The program offers people the means to join the Picture Post network and to study and analyze their own findings using DEW software. A Picture Post is an easy-to-use and inexpensive platform for repeatedly taking digital photographs as a standardized set of images of the entire 360 ° landscape, which then can be shared over the Internet on the Picture Post website. This simple concept has the potential to create a wealth of information and data on changing environmental conditions, which is important for a society grappling with the effects of environmental change. Picture Post participants study change over time in their local area, compare digital images with NASA satellite imagery and contribute towards improving their own communities. A key message in DEW is that although plants are dynamic and respond continuously to their environment, they do so either on a time-scale that most people don't notice or with a subtlety our senses can't detect. DEW has created simple tools for monitoring vegetation as a means towards understanding the connection between global climate change and local effects. Picture Posts may be added by anyone interested in monitoring a particular location. The value of a Picture Post is in the commitment of participants to take repeated photographs - monthly, weekly, or even daily - to build up a long-term record over many years. DEW is being developed by a collaborative effort led by the University of New Hampshire with the Federation of Earth Science Information Partners, the University of Southern Maine, and Worcester Polytechnic Institute. This poster will show examples of picture posts and data that can be collected and will describe our soon-to-be-released “ virtual ” picture post cell phone app. The Picture Post network is new and we invite individuals, schools, informal education centers, groups and communities to join.
NASA Technical Reports Server (NTRS)
Yanosy, James L.
1988-01-01
This manual describes how to use the Emulation Simulation Computer Model (ESCM). Based on G189A, ESCM computes the transient performance of a Space Station atmospheric revitalization subsystem (ARS) with CO2 removal provided by a solid amine water desorbed subsystem called SAWD. Many performance parameters are computed some of which are cabin CO2 partial pressure, relative humidity, temperature, O2 partial pressure, and dew point. The program allows the user to simulate various possible combinations of man loading, metabolic profiles, cabin volumes and certain hypothesized failures that could occur.
Heat pipes for terrestrial applications in dehumidification systems
NASA Technical Reports Server (NTRS)
Khattar, Mukesh K.
1988-01-01
A novel application of heat pipes which greatly enhances dehumidification performance of air-conditioning systems is presented. When an air-to-air heat pipe heat exchanger is placed between the warm return air and cold supply air streams of an air conditioner, heat is efficiently transferred from the return air to the supply air. As the warm return air precools during this process, it moves closer to its dew-point temperature. Therefore, the cooling system works less to remove moisture. This paper discusses the concept, its benefits, the challenges of incorporating heat pipes in an air-conditioning system, and the preliminary results from a field demonstration of an industrial application.
Method of controlling scale in oil recovery operations
Krajicek, Richard W.
1981-01-01
Disclosed is a method of producing highly viscous minerals from a subterranean formation by injection of an acidic, thermal vapor stream without substantial scale buildup in downstream piping, pumps and well bore. The process comprises heating the formation by injection of heat, preferably in the form of a thermal vapor stream composed of combustion gases and steam and injecting an acidic compound simultaneously with the thermal vapor stream into the formation at a temperature above the dew point of the thermal vapor stream. The acidic, thermal vapor stream increases the solubility of metal ions in connate water and thus reduces scaling in the downstream equipment during the production of viscous hydrocarbons.
Youngstown MAP, Ohio. Revised Uniform Summary of Surface Weather Observations (RUSSWO). Parts A-F.
1982-05-10
Air Weather Service ( MAC ) SCuOL2., IL 6222 R- UmmRm m "PJ M MOP Fr 4 JUN SURFACE WEATHER OSVAIWJ YOUNGSTOWN MAP OH MC #725250 N 41 16 W 080 40 ELD...percentage frequency of distribution tables OHIO YOUNGSTIOWN M "P, OHIO 20. and dew point temperatures and relative humidity); and (F) Pressure Summnary...p.ouIwuIis P i o m Qm 1 ---- .0 YN - :, 7 -AL CLIMATOLO’Y RA"CH 7 .I*.T 7C WEATHER CONDITIONS .ATH’p SEPVICE/mAC CNIIN -, JN,.S7 %N MAP OH 73-81 A U G
Beyer, Hannes; Wagner, Tino; Stemmer, Andreas
2016-01-01
Frequency-modulation atomic force microscopy has turned into a well-established method to obtain atomic resolution on flat surfaces, but is often limited to ultra-high vacuum conditions and cryogenic temperatures. Measurements under ambient conditions are influenced by variations of the dew point and thin water layers present on practically every surface, complicating stable imaging with high resolution. We demonstrate high-resolution imaging in air using a length-extension resonator operating at small amplitudes. An additional slow feedback compensates for changes in the free resonance frequency, allowing stable imaging over a long period of time with changing environmental conditions.
Activities in Cu2S-FeS-SnS melts at 1200 °C
NASA Astrophysics Data System (ADS)
Eric, R. Hurman
1993-04-01
The dew-point technique was used to measure the vapor pressures of SnS over liquid sulfides of the system Cu2S-FeS-SnS at 1200 °C. Activities of SnS were generated from the measured vapor pressures of SnS. Activities of Cu2S and FeS were evaluated both in binary and ternary melts by Gibbs-Duhem calculations from the known SnS activity data. The systems Cu2S-SnS and Cu2S-FeS exhibit negative departures from ideal behavior, while FeS-SnS melts exhibit positive deviations.
Maisotsenko cycle applications for multistage compressors cooling
NASA Astrophysics Data System (ADS)
Levchenko, D.; Yurko, I.; Artyukhov, A.; Baga, V.
2017-08-01
The present study provides the overview of Maisotsenko Cycle (M-Cycle) applications for gas cooling in compressor systems. Various schemes of gas cooling systems are considered regarding to their thermal efficiency and cooling capacity. Preliminary calculation of M-cycle HMX has been conducted. It is found that M-cycle HMX scheme allows to brake the limit of the ambient wet bulb temperature for evaporative cooling. It has demonstrated that a compact integrated heat and moisture exchange process can cool product fluid to the level below the ambient wet bulb temperature, even to the level of dew point temperature of the incoming air with substantially lower water and energy consumption requirements.
Moursi Khadiga, S; Abdel Fattah, S; Rasha; Omar, M A A; Mourad, A K
2015-01-01
Investigation throughout the subsequent years of 2011-2012 and 2012-2013 indicated that chaff scale, P. pegandii is an important economic pest on citrus trees in Abou El-Matamer area, El-Beheira Governorate, Egypt. It has been recorded in relatively high rates all over the year on three citrus varieties called Succari, Baladi and Navel oranges. Field observation and recorded data revealed that the common abundance was recorded for chaff scale on Succari oranges followed by Navel oranges then the least abundant on Baladi oranges. Generally, the calculated data on Succari oranges showed that, the population of P. pergandii reached the maximum during July and there were five highly variation periods in both the growing seasons of 2011-2012 and 2012-2013. The maximal percent of pre and adult females was observed during Spring and early Summer and reached 100% of the total counted individuals during October and December in the first year, but in the second one a higher population was recorded during Summer and early Winter months. The adult males were observed during Summer and Autumn months. Results showed also that the relationship between daily mean temperature and population density of chaff scale was weak, insignificantly negative in the two growing seasons (2011-2012 and 2012-2013) and also insignificantly but positive with relative humidity. That relationship with wind speed indicated weak positive significance in the first year and strong in the second season. The relationship between dew point and insect population was weak of positive significance in both growing seasons.
NASA Astrophysics Data System (ADS)
Matyasovszky, István; Makra, László; Csépe, Zoltán; Deák, Áron József; Pál-Molnár, Elemér; Fülöp, Andrea; Tusnády, Gábor
2015-09-01
The paper examines the sensitivity of daily airborne Ambrosia (ragweed) pollen levels of a current pollen season not only on daily values of meteorological variables during this season but also on the past meteorological conditions. The results obtained from a 19-year data set including daily ragweed pollen counts and ten daily meteorological variables are evaluated with special focus on the interactions between the phyto-physiological processes and the meteorological elements. Instead of a Pearson correlation measuring the strength of the linear relationship between two random variables, a generalised correlation that measures every kind of relationship between random vectors was used. These latter correlations between arrays of daily values of the ten meteorological elements and the array of daily ragweed pollen concentrations during the current pollen season were calculated. For the current pollen season, the six most important variables are two temperature variables (mean and minimum temperatures), two humidity variables (dew point depression and rainfall) and two variables characterising the mixing of the air (wind speed and the height of the planetary boundary layer). The six most important meteorological variables before the current pollen season contain four temperature variables (mean, maximum, minimum temperatures and soil temperature) and two variables that characterise large-scale weather patterns (sea level pressure and the height of the planetary boundary layer). Key periods of the past meteorological variables before the current pollen season have been identified. The importance of this kind of analysis is that a knowledge of the past meteorological conditions may contribute to a better prediction of the upcoming pollen season.
NASA Astrophysics Data System (ADS)
Temimi, Marouane; Chaouch, Naira; Weston, Michael; Ghedira, Hosni
2017-04-01
This study covers five fog events reported in 2014 at Abu Dhabi International Airport in the United Arab Emirates (UAE). We assess the performance of WRF-ARW model during fog conditions and we intercompare seven different PBL schemes and assess their impact on the performance of the simulations. Seven PBL schemes, namely, Yonsei University (YSU), Mellor-Yamada-Janjic (MYJ), Moller-Yamada Nakanishi and Niino (MYNN) level 2.5, Quasi-Normal Scale Elimination (QNSE-EDMF), Asymmetric Convective Model (ACM2), Grenier-Bretherton-McCaa (GBM) and MYNN level 3 were tested. Radiosonde data from the Abu Dhabi International Airport and surface measurements of relative humidity (RH), dew point temperature, wind speed, and temperature profiles were used to assess the performance of the model. All PBL schemes showed comparable skills with relatively higher performance with the QNSE scheme. The average RH Root Mean Square Error (RMSE) and BIAS for all PBLs were 15.75 % and -9.07 %, respectively, whereas the obtained RMSE and BIAS when QNSE was used were 14.65 % and -6.3 % respectively. Comparable skills were obtained for the rest of the variables. Local PBL schemes showed better performance than non-local schemes. Discrepancies between simulated and observed values were higher at the surface level compared to high altitude values. The sensitivity to lead time showed that best simulation performances were obtained when the lead time varies between 12 and 18 hours. In addition, the results of the simulations show that better performance is obtained when the starting condition is dry.
Ground based remote sensing retrievals and observations of snowfall in the Telemark region of Norway
NASA Astrophysics Data System (ADS)
Pettersen, C.; L'Ecuyer, T. S.; Wood, N.; Cooper, S.; Wolff, M. A.; Petersen, W. A.; Bliven, L. F.; Tushaus, S. A.
2017-12-01
Snowfall can be broadly categorized into deep and shallow events, based on the vertical extent of the frozen precipitation in the column. The two categories are driven by different thermodynamic and physical mechanisms in the atmosphere and surface. Though satellites can observe and recognize these patterns in snowfall, these measurements are limited - particularly in cases of shallow and light precipitation and over complex terrain. By enhancing satellite measurements with ground-based instrumentation, whether with limited-term field campaigns or long-term strategic sites, we can further our understanding and assumptions about different snowfall modes. We present data collected in a recently deployed ground suite of instruments based in Norway. The Meteorological Institute of Norway has a snow measurement suite in Haukeliseter located in the orographically complex Telemark region. This suite consists of several snow accumulation instruments as well as meteorological data (temperature, dew point, wind speeds and directions). A joint project between University of Wisconsin and University of Utah augmented this suite with a 24 GHz radar MicroRain Radar (MRR), a NASA Particle Imaging Package (PIP), and a Multi-Angle Snowflake Camera (MASC). Preliminary data from this campaign are presented along with coincident overpasses from the GPM satellite. We compare the ground-based and spaceborne remotely sensed estimates of snowfall with snow gauge observations from the Haukeliseter site. Finally, we discuss how particle size distribution and fall velocity observations from the PIP and MASC can be used to improve remotely-sensed snowfall retrievals as a function of environmental conditions at Haukeliseter.
Matyasovszky, István; Makra, László; Csépe, Zoltán; Deák, Áron József; Pál-Molnár, Elemér; Fülöp, Andrea; Tusnády, Gábor
2015-09-01
The paper examines the sensitivity of daily airborne Ambrosia (ragweed) pollen levels of a current pollen season not only on daily values of meteorological variables during this season but also on the past meteorological conditions. The results obtained from a 19-year data set including daily ragweed pollen counts and ten daily meteorological variables are evaluated with special focus on the interactions between the phyto-physiological processes and the meteorological elements. Instead of a Pearson correlation measuring the strength of the linear relationship between two random variables, a generalised correlation that measures every kind of relationship between random vectors was used. These latter correlations between arrays of daily values of the ten meteorological elements and the array of daily ragweed pollen concentrations during the current pollen season were calculated. For the current pollen season, the six most important variables are two temperature variables (mean and minimum temperatures), two humidity variables (dew point depression and rainfall) and two variables characterising the mixing of the air (wind speed and the height of the planetary boundary layer). The six most important meteorological variables before the current pollen season contain four temperature variables (mean, maximum, minimum temperatures and soil temperature) and two variables that characterise large-scale weather patterns (sea level pressure and the height of the planetary boundary layer). Key periods of the past meteorological variables before the current pollen season have been identified. The importance of this kind of analysis is that a knowledge of the past meteorological conditions may contribute to a better prediction of the upcoming pollen season.
Erdman, William L.; Lettenmaier, Terry M.
2006-07-04
An approach to wind farm design using variable speed wind turbines with low pulse number electrical output. The output of multiple wind turbines are aggregated to create a high pulse number electrical output at a point of common coupling with a utility grid network. Power quality at each individual wind turbine falls short of utility standards, but the aggregated output at the point of common coupling is within acceptable tolerances for utility power quality. The approach for aggregating low pulse number electrical output from multiple wind turbines relies upon a pad mounted transformer at each wind turbine that performs phase multiplication on the output of each wind turbine. Phase multiplication converts a modified square wave from the wind turbine into a 6 pulse output. Phase shifting of the 6 pulse output from each wind turbine allows the aggregated output of multiple wind turbines to be a 24 pulse approximation of a sine wave. Additional filtering and VAR control is embedded within the wind farm to take advantage of the wind farm's electrical impedence characteristics to further enhance power quality at the point of common coupling.
Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glissmeyer, John A.; Flaherty, Julia E.; Pekour, Mikhail S.
2014-12-02
The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system mustmore » also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.« less
NASA Technical Reports Server (NTRS)
Kavaya, Michael J.; Emmitt, G. David; Frehlich, Rod G.; Amzajerdian, Farzin; Singh, Upendra N.
2002-01-01
An end-to-end point design, including lidar, orbit, scanning, atmospheric, and data processing parameters, for space-based global profiling of atmospheric wind will be presented. The point design attempts to match the recent NASA/NOAA draft science requirements for wind measurement.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karmi, S.
1996-04-01
This document contains the baseline human health risk assessment and the ecological risk assessment (ERA) for the Point Lonely Distant Early Warning (DEW) Line radar installation. Twelve sites at the Point Lonely radar installation underwent remedial investigations (RIs) during the summer of 1993. The Vehicle Storage Area (SS14) was combined with the Inactive Landfill because the two sites were essentially co-located and were sampled during the RI as a single unit. Therefore, 11 sites are discussed in this risk assessment. The presence of chemical contamination in the soil, sediments, and surface water at the installation was evaluated and reported inmore » the Point Lonely Remedial Investigation/Feasibility Study (RI/FS). The analytical data reported in the RI/FS form the basis for the human health and ecological risk assessments. The primary chemicals of concern (COCs) at the 11 sites are diesel and gasoline from past spills and/or leaks, chlorinated solvents, and manganese. The 11 sites investigated and the types of samples collected at each site are presented.« less
Park, Bo-Yong; Lee, Mi Ji; Lee, Seung-Hak; Cha, Jihoon; Chung, Chin-Sang; Kim, Sung Tae; Park, Hyunjin
2018-01-01
Migraineurs show an increased load of white matter hyperintensities (WMHs) and more rapid deep WMH progression. Previous methods for WMH segmentation have limited efficacy to detect small deep WMHs. We developed a new fully automated detection pipeline, DEWS (DEep White matter hyperintensity Segmentation framework), for small and superficially-located deep WMHs. A total of 148 non-elderly subjects with migraine were included in this study. The pipeline consists of three components: 1) white matter (WM) extraction, 2) WMH detection, and 3) false positive reduction. In WM extraction, we adjusted the WM mask to re-assign misclassified WMHs back to WM using many sequential low-level image processing steps. In WMH detection, the potential WMH clusters were detected using an intensity based threshold and region growing approach. For false positive reduction, the detected WMH clusters were classified into final WMHs and non-WMHs using the random forest (RF) classifier. Size, texture, and multi-scale deep features were used to train the RF classifier. DEWS successfully detected small deep WMHs with a high positive predictive value (PPV) of 0.98 and true positive rate (TPR) of 0.70 in the training and test sets. Similar performance of PPV (0.96) and TPR (0.68) was attained in the validation set. DEWS showed a superior performance in comparison with other methods. Our proposed pipeline is freely available online to help the research community in quantifying deep WMHs in non-elderly adults.
ICOADS: A Foundational Database with a new Release
NASA Astrophysics Data System (ADS)
Angel, W.; Freeman, E.; Woodruff, S. D.; Worley, S. J.; Brohan, P.; Dumenil-Gates, L.; Kent, E. C.; Smith, S. R.
2016-02-01
The International Comprehensive Ocean-Atmosphere Data Set (ICOADS) offers surface marine data spanning the past three centuries and is the world's largest collection of marine surface in situ observations with approximately 300 million unique records from 1662 to the present in a common International Maritime Meteorological Archive (IMMA) format. Simple gridded monthly summary products (including netCDF) for 2° latitude x 2° longitude boxes back to 1800 and 1° x 1° boxes since 1960 are computed for each month. ICOADS observations made available in the IMMA format are taken primarily from ships (merchant, ocean research, fishing, navy, etc.) and moored and drifting buoys. Each report contains individual observations of meteorological and oceanographic variables, such as sea surface and air temperatures, winds, pressure, humidity, wet bulb, dew point, ocean waves and cloudiness. A monthly summary for an area box includes ten statistics (e.g. mean, median, standard deviation, etc.) for 22 observed and computed variables (e.g. sea surface and air temperature, wind, pressure, humidity, cloudiness, etc.). ICOADS is the most complete and heterogeneous collection of surface marine data in existence. A major new historical update, Release 3.0 (R3.0), now in production (with availability anticipated in mid-2016) will contain a variety of important updates. These updates will include unique IDs (UIDs), new IMMA attachments, ICOADS Value-Added Database (IVAD), and numerous new or improved historical and contemporary data sources. UIDs are assigned to each individual marine report, which will greatly facilitate interaction between users and data developers, and affords record traceability. A new Near-Surface Oceanographic (Nocn) attachment has been developed to include oceanographic profile elements, such as sea surface salinity, sea surface temperatures, and their associated measurement depths. Additionally, IVAD allows a feedback mechanism of data adjustments which can be stored within each IMMA report. R3.0 includes near-surface ocean profile measurements from sources such as the World Ocean Database (WOD), Shipboard Automated Meteorological and Oceanographic System (SAMOS), as well as many others. An in-depth look at the improvements and the data inputs planned for R3.0 will be further discussed.
Thirty Years of Improving the NCEP Global Forecast System
NASA Astrophysics Data System (ADS)
White, G. H.; Manikin, G.; Yang, F.
2014-12-01
Current eight day forecasts by the NCEP Global Forecast System are as accurate as five day forecasts 30 years ago. This revolution in weather forecasting reflects increases in computer power, improvements in the assimilation of observations, especially satellite data, improvements in model physics, improvements in observations and international cooperation and competition. One important component has been and is the diagnosis, evaluation and reduction of systematic errors. The effect of proposed improvements in the GFS on systematic errors is one component of the thorough testing of such improvements by the Global Climate and Weather Modeling Branch. Examples of reductions in systematic errors in zonal mean temperatures and winds and other fields will be presented. One challenge in evaluating systematic errors is uncertainty in what reality is. Model initial states can be regarded as the best overall depiction of the atmosphere, but can be misleading in areas of few observations or for fields not well observed such as humidity or precipitation over the oceans. Verification of model physics is particularly difficult. The Environmental Modeling Center emphasizes the evaluation of systematic biases against observations. Recently EMC has placed greater emphasis on synoptic evaluation and on precipitation, 2-meter temperatures and dew points and 10 meter winds. A weekly EMC map discussion reviews the performance of many models over the United States and has helped diagnose and alleviate significant systematic errors in the GFS, including a near surface summertime evening cold wet bias over the eastern US and a multi-week period when the GFS persistently developed bogus tropical storms off Central America. The GFS exhibits a wet bias for light rain and a dry bias for moderate to heavy rain over the continental United States. Significant changes to the GFS are scheduled to be implemented in the fall of 2014. These include higher resolution, improved physics and improvements to the assimilation. These changes significantly improve the tropospheric flow and reduce a tropical upper tropospheric warm bias. One important error remaining is the failure of the GFS to maintain deep convection over Indonesia and in the tropical west Pacific. This and other current systematic errors will be presented.
NASA Astrophysics Data System (ADS)
Pérez, R. C.
2009-09-01
With the objective of to get to forecast and operative determinations tool to seeding of hailstorm in the damage mitigations job that produces its precipitation in Mendoza (Argentina), we developed to software based in on surface and 500 mb. level atmospherics variable. We had used on surface dates because in this level exist to big amount of information, practically it is possible to get its measures continuously; in addition it is the level that data of damages are registered that the hail precipitation produces. The decision to use the level of 500 mb, it must to that it is the height in which the upset one of the air circulation takes place from the Pacific to Mendoza, who produces important changes and instability in the atmosphere of Mendoza, these data were obtained from the radiosonde of Santo Domingo in Santiago (Chile) and El Plumerillo (Mendoza). In the program is integrated the different indices and models obtained in ours works from investigation on the subject of last the five years. Since the October of 2004 to April of 2009 the values have been taken from the variables mentioned every day, hourly during the fight campaigns antihail (October-April). The results have integrated in the program INCAS, whom it is due to enter the surface variables: Temperature in °C, the dew point in °C, the atmospheric pressure in mb., the index of ultraviolet solar radiation, the direction and wind speed; whereas the variables of the level of 500 are due to introduce mb: height of the level of 500 mb in meters, temperature of the level in °C, the direction and wind speed to that height. From the process of these variables the type of convective process is obtained like exit of the program , that is more probable that it appears in Mendoza for these atmospheric conditions; the thresholds that trigger to the stormy processes and their possible severity. This year software was validated in his first version, obtaining itself very good results.
A hazard-independent approach for the standardised multi-channel dissemination of warning messages
NASA Astrophysics Data System (ADS)
Esbri Palomares, M. A.; Hammitzsch, M.; Lendholt, M.
2012-04-01
The tsunami disaster affecting the Indian Ocean region on Christmas 2004 demonstrated very clearly the shortcomings in tsunami detection, public warning processes as well as intergovernmental warning message exchange in the Indian Ocean region. In that regard, early warning systems require that the dissemination of early warning messages has to be executed in way that ensures that the message delivery is timely; the message content is understandable, usable and accurate. To that end, diverse and multiple dissemination channels must be used to increase the chance of the messages reaching all affected persons in a hazard scenario. In addition to this, usage of internationally accepted standards for the warning dissemination such as the Common Alerting Protocol (CAP) and Emergency Data Exchange Language (EDXL) Distribution Element specified by the Organization for the Advancement of Structured Information Standards (OASIS) increase the interoperability among different warning systems enabling thus the concept of system-of-systems proposed by GEOSS. The project Distant Early Warning System (DEWS), co-funded by the European Commission under the 6th Framework Programme, aims at strengthening the early warning capacities by building an innovative generation of interoperable tsunami early warning systems based on the above mentioned concepts following a Service-oriented Architecture (SOA) approach. The project focuses on the downstream part of the hazard information processing where customized, user-tailored warning messages and alerts flow from the warning centre to the responsible authorities and/or the public with their different needs and responsibilities. The information logistics services within DEWS generate tailored EDXL-DE/CAP warning messages for each user that must receive the message according to their preferences, e.g., settings for language, interested areas, dissemination channels, etc.. However, the significant difference in the implementation and capabilities of different dissemination channels such as SMS, email and television, have bearing on the information processing required for delivery and consumption of a DEWS EDXL-DE/CAP message over each dissemination channel. These messages may include additional information in the form of maps, graphs, documents, sensor observations, etc. Therefore, the generated messages are pre-processed by channel adaptors in the information dissemination services converting it into a format that is suitable for end-to-end delivery over the dissemination channels without any semantic distortion. The approach followed by DEWS for disseminating warnings not only relies on traditional communication ways used by the already established early warnings such as the delivery of faxes and phone calls but takes into consideration the use of other broadly used communication channels such as SMS, email, narrowcast and broadcast television, instant messaging, Voice over IP, and radio. It also takes advantage of social media channels like RSS feeds, Facebook, Twitter, etc., enabling a multiplier effect, like in the case of radio and television, and thus allowing to create mash-ups by aggregating other sources of information to the original message. Finally, status information is also important in order to assess and understand whether the process of disseminating the warning to the message consumers has been successfully completed or the process failed at some point of the dissemination chain. To that end, CAP-based messages generated within the information dissemination services provide the semantics for those fields that are of interest within the context of reporting the warning dissemination status in DEWS.
Non-hoop winding effect on bonding temperature of laser assisted tape winding process
NASA Astrophysics Data System (ADS)
Zaami, Amin; Baran, Ismet; Akkerman, Remko
2018-05-01
One of the advanced methods for production of thermoplastic composite methods is laser assisted tape winding (LATW). Predicting the temperature in LATW process is very important since the temperature at nip-point (bonding line through width) plays a pivotal role in a proper bonding and hence the mechanical performance. Despite the hoop-winding where the nip-point is the straight line, non-hoop winding includes a curved nip-point line. Hence, the non-hoop winding causes somewhat a different power input through laser-rays and-reflections and consequently generates unknown complex temperature profile on the curved nip-point line. Investigating the temperature at the nip-point line is the point of interest in this study. In order to understand this effect, a numerical model is proposed to capture the effect of laser-rays and their reflections on the nip-point temperature. To this end, a 3D optical model considering the objects in LATW process is considered. Then, the power distribution (absorption and reflection) from the optical analysis is used as an input (heat flux distribution) for the thermal analysis. The thermal analysis employs a fully-implicit advection-diffusion model to calculate the temperature on the surfaces. The results are examined to demonstrate the effect of winding direction on the curved nip-point line (tape width) which has not been considered in literature up to now. Furthermore, the results can be used for designing a better and more efficient setup in the LATW process.
Microwave Determination of Water Mole Fraction in Humid Gas Mixtures
NASA Astrophysics Data System (ADS)
Cuccaro, R.; Gavioso, R. M.; Benedetto, G.; Madonna Ripa, D.; Fernicola, V.; Guianvarc'h, C.
2012-09-01
A small volume (65 cm3) gold-plated quasi-spherical microwave resonator has been used to measure the water vapor mole fraction x w of H2O/N2 and H2O/air mixtures. This experimental technique exploits the high precision achievable in the determination of the cavity microwave resonance frequencies and is particularly sensitive to the presence of small concentrations of water vapor as a result of the high polarizability of this substance. The mixtures were prepared using the INRIM standard humidity generator for frost-point temperatures T fp in the range between 241 K and 270 K and a commercial two-pressure humidity generator operated at a dew-point temperature between 272 K and 291 K. The experimental measurements compare favorably with the calculated molar fractions of the mixture supplied by the humidity generators, showing a normalized error lower than 0.8.
NASA Astrophysics Data System (ADS)
Gerardo Ruiz Suarez, Luis
2010-05-01
38 days of air quality observations in Tenango del Aire (TENAI), south of Mexico City during MILAGRO were analyzed. That site was managed by FQA-CCA-UNAM's team with a mobile laboratory equipped with standard air quality monitors: O3, NOx, NOy, CO, SO2 and surface meteorological parameters. Hosted additional instruments were: CH2O, column NO2 (DOAS), backscatter (Lidar) and pilot balloons. Also, an ultra light plane from IMK-IFU, equipped with O3, PM10, CN, Dew Point monitors flew around the Popocatepetl and Iztaccihuatl volcanoes and above of TENAI some days during MILAGRO. Atop of TENAI, the ultra light descended in spiral until near ground and ascended to resume its path. In addition to these measurements, UNAM team ran air quality numerical simulations using the Mesoscale Climate and Chemistry Model (MCCM) and an online coupled Wind Erosion Processor to MCCM we call WEPS-MCCM. The combined observations on the ground, the ultra light plane and the models results enabled us to carry out an in depth analysis of air quality in such important region south of Mexico City. Comparison were made with the episodes classification proposed by De Foy; Ozone North and South, Convection North and South, Cold Surge and South Venting to characterize dynamics in the Valley of Mexico. The aim was to define how well connected is TENAI with the air quality network in the MCMA. The influence of the mountain gap on ozone and PM10 levels in Mexico City is analyzed by episode type. Also, the impact of the mega city of Mexico on the nearby region to the south can be understood by observations in TENAI. More polluted episode types in TENAI are those called: Cold Surge, Ozone South and South Venting due to a wind shift occurring in early afternoon that brings back polluted air that was drained south during the morning and returns back to TENAI rich in aged air parcels. March 17 was chosen to show the integrated analysis of all variables observed and modeled (MCCM) in TENAI. In that day, evidence of emissions from Tula point sources (refinery and or thermoelectric power plant) was observed very early in the day. Later in the day, plumes coming from biomass burning activities were detected by instruments at TENAI. The role of the crop lands in the mountain gap as a source of PM10 by wind erosion is highlighted both, by the ultra light plane and the coupled models WEPS-MCCM. Note: The Tenango Team members are; L. G. Ruiz-Suárez (1) , R. Torres-Jardón (1), Henry Woehrnschimmel (2), R. Steinbrecher (3), W. Junkerman (3), E. Ningenda (1), A. García-Reynoso (1), M. Melamed (1), A. Jazcilevich (1), B. E. Mar-Morales (1), M. Grutter (1) and L. Molina (4,5)
A dryer for rapid response on-line expired gas measurements.
Deno, N S; Kamon, E
1979-06-01
A dryer is described for use in on-line breath-by-breath gas analysis systems. The dryer continuously removes water vapor by condensation and controls the sample gas at 2 degrees C dew-point temperature or 5 Torr water vapor partial pressure. It is designed to operate at gas sampling flow rates from 0.5 to 1 1.min-1. The step-response time for the described system including a Beckman LB-2 CO2 analyzer, sampling tubing, and dryer is 120 ms at 1 l.min-1. The time required for gas samples to transport through the dryer is 105 ms at a gas sampling-flow rate of 1 l.min=1.
NASA Technical Reports Server (NTRS)
Hung, R. J.; Tsao, Y. D.
1988-01-01
Rawinsonde data and geosynchronous satellite imagery were used to investigate the life cycles of St. Anthony, Minnesota's severe convective storms. It is found that the fully developed storm clouds, with overshooting cloud tops penetrating above the tropopause, collapsed about three minutes before the touchdown of the tornadoes. Results indicate that the probability of producing an outbreak of tornadoes causing greater damage increases when there are higher values of potential energy storage per unit area for overshooting cloud tops penetrating the tropopause. It is also found that there is less chance for clouds with a lower moisture content to be outgrown as a storm cloud than clouds with a higher moisture content.
NASA Astrophysics Data System (ADS)
Behnke, Ruben John
The objective of this dissertation was to show that there is now enough observed humidity data available so that estimates of humidity, along with their necessary assumptions, can be replaced by measured humidity data. The range of applications that depend on humidity data is huge, ranging from water use efficiency of plants and plant stress to human health and agricultural practices. Biases due to the use of estimated humidity can be expected to have short and long impacts, decreasing the accuracy and precision of these, and many other, applications. Data from local, regional, and national observation networks was gathered, and custom quality control routines were written to remove bad data points from over 45000 stations, leaving 12533 usable stations. While still not at the same number of observations as temperature or precipitation, this number is nearly ten times as high as two decades ago. The work I performed consists of three major components, corresponding to the three main chapters of this dissertation. In chapter one, I describe data sources and quality control methods, along with some basic statistics of humidity, describing which geographic variables often used to predict temperature and precipitation can be used to do the same for humidity. Chapter two defines specific diurnal patterns (or "types") of dew point across the United States, including their attributes, causes, and potential influences. Chapter three analyzes biases in evapotranspiration, heat indices, and relative humidity levels that are a direct result of using estimated humidity data. Chapter four discusses contributions this work makes to the scientific community, and potential further research to build on what is presented here. While it may seem that the science of humidity should be well beyond data gathering and bias analysis, the fact remains that humidity is still very commonly estimated through the use of minimum temperature, and diurnal changes in dew point are often ignored. My hope is that this work makes a dent in often deeply entrenched practices, leading others to make the effort to incorporate measured humidity data into their work and study.
Rao, Qinchun; Fisher, Mary Catherine; Guo, Mufan; Labuza, Theodore P
2013-09-11
Quality loss in intermediate-moisture foods (IMF) such as high-protein nutrition bars (HPNB) in the form of hardening, nonenzymatic browning, and free amino group loss is a general concern for the manufacturers. To measure the extent of quality loss over time in terms of these negative attributes, through changing the ratio by weight between two commercial spray-dried hen egg powders, egg white (DEW) and egg yolk (DEY), the storage stability of 10 IMF systems (water activity (aw) ∼ 0.6) containing 5% glycerol, 10% shortening, 35% protein, and 50% sweetener (either maltitol or 50% high-fructose corn syrup/50% corn syrup (HFCS/CS)) were studied. Additionally, the storage stability of the DEY powder itself was investigated. Overall, during storage at different temperatures (23, 35, and 45 °C), the storage stability of DEY in dry and IMF matrices was mainly controlled by the coaction of three chemical reactions (disulfide bond interaction, Maillard reaction, and lipid oxidation). The results showed that by replacing 25% of DEW in an IMF model system with DEY, the rate of bar hardening was significantly lower than that of the models with only DEW at all temperatures due to the softening effect of the fat in DEY. Furthermore, the use of maltitol instead of HFCS/CS in all bar systems not only resulted in decreased hardness but also drastically decreased the change in the total color difference (ΔE*). Interestingly, there was no significant loss of free amino groups in the maltitol systems at any DEW/DEY ratio.
Mulching as a means of exploiting dew for arid agriculture?
NASA Astrophysics Data System (ADS)
Graf, Alexander; Kuttler, Wilhelm; Werner, Julius
2008-03-01
A traditional mulching technique used in Lanzarote, Canary Islands, allows dry farming as well as pronounced water savings in irrigation. It is known to reduce evaporational losses, but is also supposed to enhance the nocturnal condensation of water vapour from the atmosphere. The mulch layer consists of porous volcanic rock fragments abundantly available on the island. The mulched surface is believed to cool rapidly and to be more hygroscopic than a bare soil surface. This was investigated during a field experiment conducted over 68 nights during different seasons in 2001 and 2002, as well as some simple laboratory measurements. It was found that nocturnal condensation on the mulch surface (max 0.33 mm) was lower than on the bare soil surface (max 0.57 mm) or any one of three alternative mulch substrates. However, a slightly stronger nocturnal cooling of the mulched as compared to the bare surface was present. It is shown that these contrary findings can be explained by the higher hygroscopicity of the dry loam soil, resulting in condensation gains beyond the strict definition of dew. Differences in plant-availability of non-hygroscopic dew water and hygroscopic water uptakes are discussed, and conditions under which mulching would show positive condensation effects are defined. This includes a theoretical section demonstrating that non-hygroscopic mulch layers of a proper thickness can provide small amounts of dew to plant roots at the mulch-soil interface. This condensation could also happen during the day and would be favoured by a high amplitude of the diurnal atmospheric moisture cycle.
Initial evaluation of airborne water vapour measurements by the IAGOS-GHG CRDS system
NASA Astrophysics Data System (ADS)
Filges, Annette; Gerbig, Christoph; Smit, Herman G. J.; Krämer, Martina; Spelten, Nicole
2013-04-01
Accurate and reliable airborne measurements of water vapour are still a challenge. Presently, no airborne humidity sensor exists that covers the entire range of water vapour content between the surface and the upper troposphere/lower stratosphere (UT/LS) region with sufficient accuracy and time resolution. Nevertheless , these data are a pre-requisite to study the underlying processes in the chemistry and physics of the atmosphere. The DENCHAR project (Development and Evaluation of Novel Compact Hygrometer for Airborne Research) addresses this deficit by developing and characterizing novel or improved compact airborne hygrometers for different airborne applications within EUFAR (European Facility for Airborne Research). As part of the DENCHAR inter-comparison campaign in Hohn (Germany), 23 May - 1 June 2011, a commercial gas analyzer (G2401-m, Picarro Inc.,US), based on cavity ring-down spectroscopy (CRDS), was installed on a Learjet to measure water vapour, CO2, CH4 and CO. The CRDS components are identical to those chosen for integration aboard commercial airliner within IAGOS (In-service Aircraft for a Global Observing System). Thus the campaign allowed for the initial assessment validation of the long-term IAGOS H2O measurements by CRDS against reference instruments with a long performance record (FISH, the Fast In-situ Stratospheric Hygrometer, and CR2 frostpoint hygrometer, both research centre Juelich). The inlet system, a one meter long 1/8" FEP-tube connected to a Rosemount TAT housing (model 102BX, deiced) installed on a window plate of the aircraft, was designed to eliminate sampling of larger aerosols, ice particles, and water droplets, and provides about 90% of ram-pressure. In combination with a lowered sample flow of 0.1 slpm (corresponding to a 4 second response time), this ensured a fully controlled sample pressure in the cavity of 140 torr throughout an aircraft altitude operating range up to 12.5 km without the need of an upstream sampling pump. This setup ensures full compatibility with the future deployment of the analyser within IAGOS. For the initial water calibration of the instrument, a calibration of a similar instrument performed at MPI-BGC Jena against a dew point mirror (Dewmet, Michell instruments Ltd., UK) in the range from 0.7 to 3.0% was transferred to all subsequently manufactured CRDS instruments by Picarro. During the campaign the analyzer was compared against a reference frost point hygrometer, which is also used for calibration of the reference instrument FISH. The dew point mirror calibration was within 0.7 % of the FISH calibrator, but showed an offset of 14.45 ppm, which is consistent with the H2O content of dry tank air and diffusion effects through the inlet line (FEP). Furthermore, a new independent calibration method, based on the dilution effect of water vapour on CO2, was tested. It showed a 9 % low bias compared to the dew point mirror calibration. Comparison of the in-flight data against the reference systems showed that the analyzer is reliable and has a good long-term stability. Flight data from the DENCHAR campaign suggest a conservative precision estimate for measurements made at 0.4 Hz of 4 ppm for H2O < 100 ppm, and 4 % (relative) for H2O > 100 ppm. Accuracy at mixing ratios below 50 ppm was difficult to assess, as the reference instruments suffered from lack of stability. We present the results of the campaign flights and comparison with the reference instruments. The different calibration methods will be discussed.
NASA Astrophysics Data System (ADS)
Takle, E. S.; Rajewski, D. A.; Segal, M.; Elmore, R.; Hatfield, J.; Prueger, J. H.; Taylor, S. E.
2009-12-01
The US Midwest is a unique location for wind power production because wind farms in this region, unlike any other, are co-located within major agricultural production systems that are among the most highly productive in the world. Iowa has over 3,000 MW of installed power in wind farms typically consisting of 75-120 turbines positioned within agricultural fields with irregular spacing but inter-turbine distances in some cases less than 300 m. Wind turbines extract energy from the ambient flow and change mean and turbulent characteristics of wind flow over and within the crop canopy. Turbulent exchange of air from within the crop canopy regulates vertical fluxes of heat, moisture, momentum, and CO2. Changes in wind speed and turbulence structure by wind farms and isolated wind turbines will influence crop growth, productivity, and seed quality in unknown ways. For instance, enhanced vertical fluxes of heat and moisture may help cool the crop on hot summer days (beneficial) but may enhance loss of soil moisture (detrimental). Faster drying of dew from the crop in the morning reduces leaf wetness, which is a condition favoring growth of fungus, mold and toxins. Corn and soybeans typically draw down ambient CO2 levels by 15-20% during the day in the peak growing season, providing an opportunity to enhance downward fluxes of CO2 into the crop canopy by turbine-induced turbulence. Reduction of high winds and resulting leaf shredding and stalk lodging are documented positive effects of agricultural shelterbelts and may be benefits of turbines as well. Enhanced surface evaporation during fall dry-down would improve seed readiness for storage and reduce artificial drying costs. Modification of surface wind convergence/divergence patterns may enhance convection and change rainfall patterns and modify snow deposition, melting, and soil-moisture-recharge in winter. Wind machines are widely used in orchards and vineyards for avoiding killing freezes, but turbine benefits for such purposes for growing commodity agricultural crops are unknown. Suppressing effects of a premature freeze could extend the growing season by two or more weeks. Aerodynamic surface roughness influences the mean wind at hub height of wind turbines. Type of crop (e.g., corn vs. soybeans) and stage of growth will influence roughness, as will management practices (smooth surface vs. crop residue and tillage-induced roughness). Management of crop residue and snow cover influences surface albedo and hence diabatic influences on turbulent loss of momentum at the surface. We have launched a pilot project to assess the interaction of turbines with crops in Iowa by use of models and measurements. Preliminary studies show that turbulence kinetic energy in the lee of turbines may be enhanced by as much as 300% near hub height and 40% at 10 m above the ground under neutral flow conditions. Field observations of fluxes of CO2, heat, and water vapor have been made outside of wind farms, and plans call for simultaneous measurements to be made within and outside of wind farms.
Effects of Surface Wettability on the Porosity and Wickability of Frost
NASA Astrophysics Data System (ADS)
Witt, Katherine; Ahmadi, Farzad; Boreyko, Jonathan
2017-11-01
The wicking of liquids through porous media has been studied for many materials, but never for frost, despite its implications for arctic oil spills and oil-infused surfaces. Here, we characterize silicone oils wicking up frost sheets. A layer of frost was grown on aluminum plates of varying surface wettability: superhydrophilic, hydrophilic, hydrophobic, and superhydrophobic. Once the desired frost thickness was grown, a humidity chamber was used to maintain the frost at the dew point and the bottom of the plate was dipped in a reservoir of fluorescent silicone oil. For all surfaces, the wicking rate of the oil increased with increasing wettability. For the wetting surfaces, this is manifested in the length vs. time data following the classical Washburn equation, exhibiting a power slope of about 1/2 and resulting in a larger effective pore radius with increasing wettability. However, we observed that on the non-wetting surfaces, the discrete distribution of the frosted dew droplets resulted in a new scaling law with a slope much less than 1/2, especially for the superhydrophobic surface which promoted jumping-droplet condensation. This research shows that the wicking of oil up a layer of frost can give insight into the morphology of frost. Conversely, if the underlying wettability of a frost sheet can be controlled, the spread of oil can be widely tuned. This work was supported by a Virginia Space Grant Consortium Undergraduate Research Scholarship (PMPTX7EP).
Secure Automated Microgrid Energy System (SAMES)
2016-12-01
with embedded algorithm to share power between each other; • Wind Turbine (WT) Simulator, max 80 kW (4×20 kW), 480 V, Running Wind Generation...Temp, Rain, Wind ........................ 39 Figure 22. Point Loma, Box and Whisker Plot, Hourly Sum of Consumption ............................ 40...Figure 27. Coronado, Consumption vs Average Daily SD Temp, Rainfall, Wind ....................... 44 Figure 28. Naval Base Point Loma, One Line, Solar
The 80 megawatt wind power project at Kahuku Point, Hawaii
NASA Technical Reports Server (NTRS)
Laessig, R. R.
1982-01-01
Windfarms Ltd. is developing the two largest wind energy projects in the world. Designed to produce 80 megawatts at Kahuku Point, Hawaii and 350 megawatts in Solano County, California, these projects will be the prototypes for future large-scale wind energy installations throughout the world.
Nansen, Christian; Vaughn, Kathy; Xue, Yingen; Rush, Charlie; Workneh, Fekede; Goolsby, John; Troxclair, Noel; Anciso, Juan; Gregory, Ashley; Holman, Daniel; Hammond, Abby; Mirkov, Erik; Tantravahi, Pratyusha; Martini, Xavier
2011-08-01
Approximately US $1.3 billion is spent each year on insecticide applications in major row crops. Despite this significant economic importance, there are currently no widely established decision-support tools available to assess suitability of spray application conditions or of the predicted quality or performance of a given commercial insecticide applications. We conducted a field study, involving 14 commercial spray applications with either fixed wing airplane (N=8) or ground rig (N=6), and we used environmental variables as regression fits to obtained spray deposition (coverage in percentage). We showed that (1) ground rig applications provided higher spray deposition than aerial applications, (2) spray deposition was lowest in the bottom portion of the canopy, (3) increase in plant height reduced spray deposition, (4) wind speed increased spray deposition, and (5) higher ambient temperatures and dew point increased spray deposition. Potato psyllid, Bactericera cockerelli (Sulc) (Hemiptera: Triozidae), mortality increased asymptotically to approximately 60% in response to abamectin spray depositions exceeding around 20%, whereas mortality of psyllid adults reached an asymptotic response approximately 40% when lambda-cyhalothrin/thiamethoxam spray deposition exceeded 30%. A spray deposition support tool was developed (http://pilcc.tamu.edu/) that may be used to make decisions regarding (1) when is the best time of day to conduct spray applications and (2) selecting which insecticide to spray based on expected spray deposition. The main conclusion from this analysis is that optimization of insecticide spray deposition should be considered a fundamental pillar of successful integrated pest management programs to increase efficiency of sprays (and therefore reduce production costs) and to reduce risk of resistance development in target pest populations.
Climate and ET: Does Plant Water Requirements Increase during Droughts?
NASA Astrophysics Data System (ADS)
Fipps, G.; Bonaiti, G.; Swanson, C.
2012-04-01
With the expected rise in global warming and increased frequency of extreme climate variability in the coming decades, conservation and efficient use of water resources is essential and must make use of the most accurate and representative data available. Historically, governmental and private organizations have used estimates of plant water use estimated from a variety of methods for long-term water planning, for designing hydraulic structures, and for establishing regulatory guidance and conservation programs intended to reduce water waste. In recent years, there has been an expansion of agricultural weather station networks which report daily ETo (potential evapotranspiration) and commercial irrigation controllers with instrumentation which calculate real-time ETo from weather parameters. Efforts are underway to use this more precise information for regional water planning and ETo is routinely used for designing and implementing drought response programs. The year 2011 marked the driest year on record in the State of Texas. Compounding the lack of rainfall was record heat during the summer of 2011. In 2011, real-time ETo (reference evapotranspiration) data in Texas was 30 to 50% higher than historic averages. The implications are quite serious, as most current water planning and drought contingency plans do not take into consideration increases in ET during such periods, and irrigation planning and capacity sizing are based on historic averages of consumptive use. This paper examines the relationship between ET and climate during this extreme climatic event. While the solar radiation was near normal levels, temperature and wind was much higher and dew points much lower than norms. The variability and statistical difference between long term average ETo and ETo measurements (from 2006 to 2011) for selected weather stations of the Texas ET Network.
Performance of a solar augmented heat pump
NASA Astrophysics Data System (ADS)
Bedinger, A. F. G.; Tomlinson, J. J.; Reid, R. L.; Chaffin, D. J.
Performance of a residential size solar augmented heat pump is reported for the 1979-1980 heating season. The facility located in Knoxville, Tennessee, has a measured heat load coefficient of 339.5 watt/C (644 BTU/hr- F). The solar augmented heat pump system consists of 7.4 cu m of one inch diameter crushed limestone. The heat pump is a nominal 8.8 KW (2 1/2 ton) high efficiency unit. The system includes electric resistance heaters to give the option of adding thermal energy to the pebble bed storage during utility off-peak periods, thus offering considerable load management capability. A 15 KW electric resistance duct heater is used to add thermal energy to the pebble bin as required during off-peak periods. Hourly thermal performance and on site weather data was taken for the period November 1, 1979, to April 13, 1980. Thermal performance data consists of heat flow summations for all modes of the system, pebble bed temperatures, and space temperature. Weather data consists of dry bulb temperature, dew point temperature, total global insolation (in the plane of the collector), and wind speed and direction. An error analysis was performed and the least accurate of the measurements was determined to be the heat flow at 5%. Solar system thermal performance factor was measured to be 8.77. The heat pump thermal performance factor was 1.64. Total system seasonal performance factor was measured to be 1.66. Using a modified version of TRNSYS, the thermal performance of this system was simulated. When simulation results were compared with data collected onsite, the predicted heat flow and power consumption generally were within experimental accuracy.
NASA Astrophysics Data System (ADS)
Szilagyi, Jozsef
2018-02-01
Trends in monthly evapotranspiration (ET) rates across Nebraska, the most intensely irrigated state within the US, were calculated by the calibration-free version of the nonlinear complementary relationship of evaporation over the 1979-2015 period utilizing North American Regional Reanalysis (NARR) net radiation, 10-m wind velocity, as well as Parameter Regression Independent Slope Model (PRISM) air- and dew-point temperature data. State-averaged modeled ET rates rose by 5.5 mm decade-1 due to the presence of wide-spread large-scale irrigation projects in accordance with a 2.4 mm decade-1 increase in PRISM precipitation (P) and a simultaneous -2.8 mm decade-1 drop in United States Geological Survey's state-averaged annual streamflow rates, raising the state-wide ET to P ratio from 0.89 to 0.91 over the modeled time-period. ET rates over irrigated crops increased by 7 mm decade-1 despite a -4.4 mm decade-1 drop in precipitation rates. A similar increase in ET rates (6 mm decade-1) required 8.1 mm decade-1 increase in precipitation rates across the non-irrigated Sand Hills of Nebraska. Published NARR ET rates are unable to pick up this unusual regional trend. Since an increase in precipitation rates should normally decrease the ET ratio, as predicted by the Budyko curve, this study yields evidence on how dramatically sustained large-scale irrigation can alter the regional hydrologic cycle not only through a) trivially depleting streamflow rates and/or lowering groundwater table levels; b) suppressing precipitation locally (while enhancing it a long distance downwind), but also; c) reversing the trajectory of the regional ET ratio under generally increasing trends of precipitation.
NASA Astrophysics Data System (ADS)
Zhang, T.; Stackhouse, P. W., Jr.; Chandler, W.; Hoell, J. M.; Westberg, D.; Whitlock, C. H.
2010-12-01
NASA's POWER project, or the Prediction of the Worldwide Energy Resources project, synthesizes and analyzes data on a global scale. The products of the project find valuable applications in the solar and wind energy sectors of the renewable energy industries. The primary source data for the POWER project are NASA's World Climate Research Project (WCRP)/Global Energy and Water cycle Experiment (GEWEX) Surface Radiation Budget (SRB) project (Release 3.0) and the Global Modeling and Assimilation Office (GMAO) Goddard Earth Observing System (GEOS) assimilation model (V 4.0.3). Users of the POWER products access the data through NASA's Surface meteorology and Solar Energy (SSE, Version 6.0) website (http://power.larc.nasa.gov). Over 200 parameters are available to the users. The spatial resolution is 1 degree by 1 degree now and will be finer later. The data covers from July 1983 to December 2007, a time-span of 24.5 years, and are provided as 3-hourly, daily and monthly means. As of now, there have been over 18 million web hits and over 4 million data file downloads. The POWER products have been systematically validated against ground-based measurements, and in particular, data from the Baseline Surface Radiation Network (BSRN) archive, and also against the National Solar Radiation Data Base (NSRDB). Parameters such as minimum, maximum, daily mean temperature and dew points, relative humidity and surface pressure are validated against the National Climate Data Center (NCDC) data. SSE feeds data directly into Decision Support Systems including RETScreen International clean energy project analysis software that is written in 36 languages and has greater than 260,000 users worldwide.