Sample records for diagnostic accuracy da

  1. Establishment and Comparison of Two Different Diagnostic Platforms for Detection of DENV1 NS1 Protein

    PubMed Central

    Tang, Yin-Liang; Chiu, Chien-Yu; Lin, Chun-Yu; Huang, Chung-Hao; Chen, Yen-Hsu; Destura, Raul V.; Chao, Day-Yu; Wu, Han-Chung

    2015-01-01

    Dengue virus (DENV) infection is currently at pandemic levels, with populations in tropical and subtropical regions at greatest risk of infection. Early diagnosis and management remain the cornerstone for good clinical outcomes, thus efficient and accurate diagnostic technology in the early stage of the disease is urgently needed. Serotype-specific monoclonal antibodies (mAbs) against the DENV1 nonstructural protein 1 (NS1), DA12-4, DA13-2, and DA15-3, which were recently generated using the hybridoma technique, are suitable for use in diagnostic platforms. Immunofluorescence assay (IFA), enzyme-linked immunosorbent assay (ELISA) and Western blot analysis further confirmed the serotype specificity of these three monoclonal antibodies. The ELISA-based diagnostic platform was established using the combination of two highly sensitive mAbs (DA15-3 and DB20-6). The same combination was also used for the flow cytometry-based diagnostic platform. We report here the detection limits of flow cytometry-based and ELISA-based diagnostic platforms using these mAbs to be 0.1 and 1 ng/mL, respectively. The collected clinical patient serum samples were also assayed by these two serotyping diagnostic platforms. The sensitivity and specificity for detecting NS1 protein of DENV1 are 90% and 96%, respectively. The accuracy of our platform for testing clinical samples is more advanced than that of the two commercial NS1 diagnostic platforms. In conclusion, our platforms are suitable for the early detection of NS1 protein in DENV1 infected patients. PMID:26610481

  2. Real-time Raman spectroscopy for in vivo, online gastric cancer diagnosis during clinical endoscopic examination.

    PubMed

    Duraipandian, Shiyamala; Sylvest Bergholt, Mads; Zheng, Wei; Yu Ho, Khek; Teh, Ming; Guan Yeoh, Khay; Bok Yan So, Jimmy; Shabbir, Asim; Huang, Zhiwei

    2012-08-01

    Optical spectroscopic techniques including reflectance, fluorescence and Raman spectroscopy have shown promising potential for in vivo precancer and cancer diagnostics in a variety of organs. However, data-analysis has mostly been limited to post-processing and off-line algorithm development. In this work, we develop a fully automated on-line Raman spectral diagnostics framework integrated with a multimodal image-guided Raman technique for real-time in vivo cancer detection at endoscopy. A total of 2748 in vivo gastric tissue spectra (2465 normal and 283 cancer) were acquired from 305 patients recruited to construct a spectral database for diagnostic algorithms development. The novel diagnostic scheme developed implements on-line preprocessing, outlier detection based on principal component analysis statistics (i.e., Hotelling's T2 and Q-residuals) for tissue Raman spectra verification as well as for organ specific probabilistic diagnostics using different diagnostic algorithms. Free-running optical diagnosis and processing time of < 0.5 s can be achieved, which is critical to realizing real-time in vivo tissue diagnostics during clinical endoscopic examination. The optimized partial least squares-discriminant analysis (PLS-DA) models based on the randomly resampled training database (80% for learning and 20% for testing) provide the diagnostic accuracy of 85.6% [95% confidence interval (CI): 82.9% to 88.2%] [sensitivity of 80.5% (95% CI: 71.4% to 89.6%) and specificity of 86.2% (95% CI: 83.6% to 88.7%)] for the detection of gastric cancer. The PLS-DA algorithms are further applied prospectively on 10 gastric patients at gastroscopy, achieving the predictive accuracy of 80.0% (60/75) [sensitivity of 90.0% (27/30) and specificity of 73.3% (33/45)] for in vivo diagnosis of gastric cancer. The receiver operating characteristics curves further confirmed the efficacy of Raman endoscopy together with PLS-DA algorithms for in vivo prospective diagnosis of gastric cancer. This work successfully moves biomedical Raman spectroscopic technique into real-time, on-line clinical cancer diagnosis, especially in routine endoscopic diagnostic applications.

  3. Real-time Raman spectroscopy for in vivo, online gastric cancer diagnosis during clinical endoscopic examination

    NASA Astrophysics Data System (ADS)

    Duraipandian, Shiyamala; Sylvest Bergholt, Mads; Zheng, Wei; Yu Ho, Khek; Teh, Ming; Guan Yeoh, Khay; Bok Yan So, Jimmy; Shabbir, Asim; Huang, Zhiwei

    2012-08-01

    Optical spectroscopic techniques including reflectance, fluorescence and Raman spectroscopy have shown promising potential for in vivo precancer and cancer diagnostics in a variety of organs. However, data-analysis has mostly been limited to post-processing and off-line algorithm development. In this work, we develop a fully automated on-line Raman spectral diagnostics framework integrated with a multimodal image-guided Raman technique for real-time in vivo cancer detection at endoscopy. A total of 2748 in vivo gastric tissue spectra (2465 normal and 283 cancer) were acquired from 305 patients recruited to construct a spectral database for diagnostic algorithms development. The novel diagnostic scheme developed implements on-line preprocessing, outlier detection based on principal component analysis statistics (i.e., Hotelling's T2 and Q-residuals) for tissue Raman spectra verification as well as for organ specific probabilistic diagnostics using different diagnostic algorithms. Free-running optical diagnosis and processing time of < 0.5 s can be achieved, which is critical to realizing real-time in vivo tissue diagnostics during clinical endoscopic examination. The optimized partial least squares-discriminant analysis (PLS-DA) models based on the randomly resampled training database (80% for learning and 20% for testing) provide the diagnostic accuracy of 85.6% [95% confidence interval (CI): 82.9% to 88.2%] [sensitivity of 80.5% (95% CI: 71.4% to 89.6%) and specificity of 86.2% (95% CI: 83.6% to 88.7%)] for the detection of gastric cancer. The PLS-DA algorithms are further applied prospectively on 10 gastric patients at gastroscopy, achieving the predictive accuracy of 80.0% (60/75) [sensitivity of 90.0% (27/30) and specificity of 73.3% (33/45)] for in vivo diagnosis of gastric cancer. The receiver operating characteristics curves further confirmed the efficacy of Raman endoscopy together with PLS-DA algorithms for in vivo prospective diagnosis of gastric cancer. This work successfully moves biomedical Raman spectroscopic technique into real-time, on-line clinical cancer diagnosis, especially in routine endoscopic diagnostic applications.

  4. [Diagnostic Accuracy of the LiSe-DaZ for Children with Specific Language Impairment].

    PubMed

    Stephan, T; Keilmann, A

    2015-12-01

    Currently, only few tests for the development of speech and language exist for bi- or multilingual children in Germany. One of those, the LiSe-DaZ (Linguistic performance measurement - German as a second language), was examined in a prospective study regarding its practicability and the sensitivity to detect children with specific language impairment in a group of children aged 5 to 7 who suffered from a severe language impairment according to clinical tests. 74 children (mean age: 60 months; 46% monolingual German-speaking; 54% bi- or multilingual) with severe specific language impairment were examined with the LiSe-DaZ in addition to the clinical established diagnostic during their in-patient stay in the hospital. The children, on average, showed in the receptive language abilities (LiSe-DaZ vs. TROG-D), the expressive vocabulary (LiSe-DaZ vs. AWST-R or WWT) and in the use of prepositions (LiSe-DaZ vs. Ravensburger Dysgrammatical clinical trial) significantly (p<0,0005) better results in the LiSe-DaZ. Thus, the majority of children were diagnosed as language impaired by clinically established tests whereas the LiSe-DaZ considered the children's language development to be normal. This difference was consistently more prominent for children with German as a second language. Compared with the clinically established tests, the informative value of the LiSe-DaZ turned out to be insufficient. The LiSe-DaZ does not detect children with the need of language therapy. Nevertheless, a norming of the established speech tests for bi- or multilingual children would be desirable to avoid unfounded judgements. © Georg Thieme Verlag KG Stuttgart · New York.

  5. Efficacy of Transcerebellar Diameter/Abdominal Circumference Versus Head Circumference/Abdominal Circumference in Predicting Asymmetric Intrauterine Growth Retardation

    PubMed Central

    Bhimarao; Bhat, Venkataramana; Gowda, Puttanna VN

    2015-01-01

    Background The high incidence of IUGR and its low recognition lead to increasing perinatal morbidity and mortality for which prediction of IUGR with timely management decisions is of paramount importance. Many studies have compared the efficacy of several gestational age independent parameters and found that TCD/AC is a better predictor of asymmetric IUGR. Aim To compare the accuracy of transcerebellar diameter/abdominal circumference with head circumference/abdominal circumference in predicting asymmetric intrauterine growth retardation after 20 weeks of gestation. Materials and Methods The prospective study was conducted over a period of one year on 50 clinically suspected IUGR pregnancies who were evaluated with 3.5 MHz frequency ultrasound scanner by a single sonologist. BPD, HC, AC and FL along with TCD were measured for assessing the sonological gestational age. Two morphometric ratios- TCD/AC and HC/AC were calculated. Estimated fetal weight was calculated for all these pregnancies and its percentile was determined. Statistical Methods The TCD/AC and HC/AC ratios were correlated with advancing gestational age to know if these were related to GA. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and diagnostic accuracy (DA) for TCD/AC and HC/AC ratios in evaluating IUGR fetuses were calculated. Results In the present study, linear relation of TCD and HC in IUGR fetuses with gestation was noted. The sensitivity, specificity, PPV, NPV & DA were 88%, 93.5%, 77.1%, 96.3% & 92.4% respectively for TCD/AC ratio versus 84%, 92%, 72.4%, 95.8% & 90.4% respectively for HC/AC ratio in predicting IUGR. Conclusion Both ratios were gestational age independent and can be used in detecting IUGR with good diagnostic accuracy. However, TCD/AC ratio had a better diagnostic validity and accuracy compared to HC/AC ratio in predicting asymmetric IUGR. PMID:26557588

  6. Diagnostic efficiency of abattoir meat inspection service in Ethiopia to detect carcasses infected with Mycobacterium bovis: implications for public health.

    PubMed

    Biffa, Demelash; Bogale, Asseged; Skjerve, Eystein

    2010-08-06

    Bovine Tuberculosis (BTB) is a widespread and endemic disease of cattle in Ethiopia posing a significant threat to public health. Regular surveillance by skin test, bacteriology and molecular methods is not feasible due to lack of resource. Thus, routine abattoir (RA) inspection will continue to play a key role for national surveillance. We evaluated efficiency of RA inspection for diagnosis of Mycobacterium bovis infection and discussed its public health implications in light of a high risk of human exposure. The study was conducted in five abattoirs: Addis Ababa, Adama, Hawassa, Yabello and Melge-Wondo abattoirs. The efficiency of routine abattoir (RA) inspection was validated in comparison to detailed abattoir (DA) inspection, followed by culture and microscopy (CM) and region of difference (RD) deletion analysis. Diagnostic accuracies (with corresponding measures of statistical uncertainty) were determined by computing test property statistics (sensitivity and specificity) and likelihood estimations using web-based SISA diagnostic statistics software. Post-test probability of detecting TB infected carcasses was estimated using nomograms. Agreement between RA and DA inspections was measured using kappa statistics. The study was conducted and reported in accordance with standards for reporting of diagnostic accuracy (STARD) requirements. Both routine and detailed meat inspection protocols were performed on a subpopulation of 3322 cattle selected randomly from among 78,269 cattle slaughtered during the study period. Three hundred thirty seven carcasses identified through detailed meat inspection protocols were subjected to culture and microscopy; of the 337, a subset of 105 specimens for culture and microscopy were subjected to further molecular testing. There was a substantial agreement between RA and DA inspections in Addis Ababa (Kappa = 0.7) and Melge-Wondo abattoirs (Kappa = 0.67). In Adama, Hawassa and Yabello abattoirs, the agreement was however poor (Kappa

  7. Diagnostic efficiency of abattoir meat inspection service in Ethiopia to detect carcasses infected with Mycobacterium bovis: Implications for public health

    PubMed Central

    2010-01-01

    Background Bovine Tuberculosis (BTB) is a widespread and endemic disease of cattle in Ethiopia posing a significant threat to public health. Regular surveillance by skin test, bacteriology and molecular methods is not feasible due to lack of resource. Thus, routine abattoir (RA) inspection will continue to play a key role for national surveillance. We evaluated efficiency of RA inspection for diagnosis of Mycobacterium bovis infection and discussed its public health implications in light of a high risk of human exposure. Methods The study was conducted in five abattoirs: Addis Ababa, Adama, Hawassa, Yabello and Melge-Wondo abattoirs. The efficiency of routine abattoir (RA) inspection was validated in comparison to detailed abattoir (DA) inspection, followed by culture and microscopy (CM) and region of difference (RD) deletion analysis. Diagnostic accuracies (with corresponding measures of statistical uncertainty) were determined by computing test property statistics (sensitivity and specificity) and likelihood estimations using web-based SISA diagnostic statistics software. Post-test probability of detecting TB infected carcasses was estimated using nomograms. Agreement between RA and DA inspections was measured using kappa statistics. The study was conducted and reported in accordance with standards for reporting of diagnostic accuracy (STARD) requirements. Both routine and detailed meat inspection protocols were performed on a subpopulation of 3322 cattle selected randomly from among 78,269 cattle slaughtered during the study period. Three hundred thirty seven carcasses identified through detailed meat inspection protocols were subjected to culture and microscopy; of the 337, a subset of 105 specimens for culture and microscopy were subjected to further molecular testing. Results There was a substantial agreement between RA and DA inspections in Addis Ababa (Kappa = 0.7) and Melge-Wondo abattoirs (Kappa = 0.67). In Adama, Hawassa and Yabello abattoirs, the agreement was however poor (Kappa ≤ 0.2). RA inspection was able to detect only 117 of the total 3322 carcasses inspected (3.5%). The sensitivity (Sn) and specificity (Sp) of RA inspection were 28.2% (95/337) [95%CI: 23.4-33.0] and 99.3% (2963/2985) [95%CI: 99.0-99.6], respectively, when DA inspection was considered as reference test. When culture and microscopy (CM) was considered as reference test, the Sn and Sp of RA were 55.2% (58/105) [95%CI: 45.7-64.7] and 84.1% (195/232) [95%CI: 79.3-88.8]. RA inspection failed to detect 71.8% (242/337) and 44.8% (47/105) of TB infected carcasses as judged by DA inspection and CM, respectively. On the other hand, a much higher sensitivity of DA was obtained when CM and RD deletion analysis were considered as reference tests (96.3% (105/109) and 100.0% (24/24), respectively). Conclusions The study results indicate that meat inspection protocols currently utilized in abattoirs are insufficient to detect the majority of TB lesions at the gross level. DA inspection protocols were demonstrated to improve the detection level by approximately 3-fold. The failure of current inspection techniques to detect approximately 70% of carcasses presented with grossly-visible lesions of TB at the slaughter-plants indicates the magnitude of meat-borne zoonotic TB as an on-going risk to public health. Standardization of abattoir inspection protocols (in line with international sanitary requirements), enhanced training and proficiency testing of meat inspections, and raising public awareness are recommended as essential and cost-effective interventions to improve meat inspection service in Ethiopia, with subsequent protection of consumers' health. PMID:20691081

  8. In vivo diagnosis of cervical precancer using Raman spectroscopy and genetic algorithm techniques.

    PubMed

    Duraipandian, Shiyamala; Zheng, Wei; Ng, Joseph; Low, Jeffrey J H; Ilancheran, A; Huang, Zhiwei

    2011-10-21

    This study aimed to evaluate the clinical utility of applying near-infrared (NIR) Raman spectroscopy and genetic algorithm-partial least squares-discriminant analysis (GA-PLS-DA) to identify biomolecular changes of cervical tissues associated with dysplastic transformation during colposcopic examination. A total of 105 in vivo Raman spectra were measured from 57 cervical sites (35 normal and 22 precancer sites) of 29 patients recruited, in which 65 spectra were from normal sites, while 40 spectra were from cervical precancerous lesions (i.e., 7 low-grade CIN and 33 high-grade CIN). The GA feature selection technique incorporated with PLS was utilized to study the significant biochemical Raman bands for differentiation between normal and precancer cervical tissues. The GA-PLS-DA algorithm with double cross-validation (dCV) identified seven diagnostically significant Raman bands in the ranges of 925-935, 979-999, 1080-1090, 1240-1260, 1320-1340, 1400-1420, and 1625-1645 cm(-1) related to proteins, nucleic acids and lipids in tissue, and yielded a diagnostic accuracy of 82.9% (sensitivity of 72.5% (29/40) and specificity of 89.2% (58/65)) for precancer detection. The results of this exploratory study suggest that Raman spectroscopy in conjunction with GA-PLS-DA and dCV methods has the potential to provide clinically significant discrimination between normal and precancer cervical tissues at the molecular level.

  9. MR evaluation of breast lesions obtained by diffusion-weighted imaging with background body signal suppression (DWIBS) and correlations with histological findings.

    PubMed

    Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Capolongo, Arcangela; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe

    2014-07-01

    Diffusion imaging represents a new imaging tool for the diagnosis of breast cancer. This study aims to investigate the role of diffusion-weighted MRI with background body signal suppression (DWIBS) for evaluating breast lesions. 90 patients were prospectively evaluated by MRI with STIR, TSE-T2, contrast enhanced THRIVE-T1 and DWIBS sequences. DWIBS were analyzed searching for the presence of breast lesions and calculating the ADC value. ADC values of ≤1.44×10(-3)mm(2)/s were considered suspicious for malignancy. This analysis was then compared with the histological findings. Sensitivity, specificity, diagnostic accuracy (DA), positive predictive value (PPV) and negative (NPV) were calculated. In 53/90 (59%) patients, DWIBS indicated the presence of breast lesions, 16 (30%) with ADC values of >1.44 and 37 (70%) with ADC≤1.44. The comparison with histology showed 25 malignant and 28 benign lesions. DWIBS sequences obtained sensitivity, specificity, DA, PPV and NPV values of 100, 82, 87, 68 and 100%, respectively. DWIBS can be proposed in the MRI breast protocol representing an accurate diagnostic complement. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Protocol of a single group prospective observational study on the diagnostic value of 3T susceptibility weighted MRI of nigrosome-1 in patients with parkinsonian symptoms: the N3iPD study (nigrosomal iron imaging in Parkinson's disease).

    PubMed

    Schwarz, Stefan T; Xing, Yue; Naidu, Saadnah; Birchall, Jim; Skelly, Rob; Perkins, Alan; Evans, Jonathan; Sare, Gill; Martin-Bastida, Antonio; Bajaj, Nin; Gowland, Penny; Piccini, Paola; Auer, Dorothee P

    2017-12-14

    Parkinson's disease (PD) is the most common movement disorder in the elderly and is characterised clinically by bradykinesia, tremor and rigidity. Diagnosing Parkinson's can be difficult especially in the early stages. High-resolution nigrosome MRI offers promising diagnostic accuracy of patients with established clinical symptoms; however, it is unclear whether this may help to establish the diagnosis in the early stages of PD, when there is diagnostic uncertainty. In this scenario, a single photon emission CT scan using a radioactive dopamine transporter ligand can help to establish the diagnosis, or clinical follow-up may eventually clarify the diagnosis. A non-invasive, cost-effective diagnostic test that could replace this would be desirable. We therefore aim to prospectively test whether nigrosome MRI is as useful as DaTSCAN to establish the correct diagnosis in people with minor or unclear symptoms suspicious for PD. In a prospective study we will recruit 145 patients with unclear symptoms possibly caused by Parkinson's from three movement disorder centres in the UK to take part in the study. We will record the Movement Disorder Society - Unified Parkinson's Disease Rating Scale, and participants will undergo DaTSCAN and high-resolution susceptibility weighted MRI at a field strength of 3T. DaTSCANs will be assessed visually and semiquantitatively; MRI scans will be visually assessed for signal loss in nigrosome-1 by blinded investigators. We will compare how the diagnosis suggested by MRI compares with the diagnosis based on DaTSCAN and will also validate the diagnosis based on the two tests with a clinical examination performed at least 1 year after the initial presentation as a surrogate gold standard diagnostic test. The local ethics commission (Health Research Authority East Midlands - Derby Research Ethics Committee) has approved this study (REC ref.: 16/EM/0229). The study is being carried out under the principles of the Declaration of Helsinki (64th, 2013) and Good Clinical Practice standards. We have included a number of 15 research-funded DaTSCAN in the research protocol. This is to compensate for study site-specific National Health Service funding for this investigation in affected patients. We therefore have also obtained approval from the Administration of Radioactive Substances Administration Committee (ARSAC Ref 253/3629/35864). All findings will be presented at relevant scientific meetings and published in peer-reviewed journals, on the study website, and disseminated in lay and social media where appropriate. NCT03022357; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Detection of a combination of serum IgG and IgA antibodies against selected mycobacterial targets provides promising diagnostic signatures for active TB

    PubMed Central

    Chegou, Novel N.; Kriel, Belinda; Jacobs, Ruschca; Kidd, Martin; Loxton, Andre G.; Kaempfer, Susanne; Singh, Mahavir; Walzl, Gerhard

    2017-01-01

    Immunoglobulin G (IgG) based tests for the diagnosis of active tuberculosis (TB) disease often show a lack of specificity in TB endemic regions, which is mainly due to a high background prevalence of LTBI. Here, we investigated the combined performance of the responses of different Ig classes to selected mycobacterial antigens in primary healthcare clinic attendees with signs and symptoms suggestive of TB. The sensitivity and specificity of IgA, IgG and/or IgM to LAM and 7 mycobacterial protein antigens (ESAT-6, Tpx, PstS1, AlaDH, MPT64, 16kDa and 19kDa) and 2 antigen combinations (TUB, TB-LTBI) in the plasma of 63 individuals who underwent diagnostic work-up for TB after presenting with symptoms and signs compatible with possible active TB were evaluated. Active TB was excluded in 42 individuals of whom 21 has LTBI whereas active TB was confirmed in 21 patients of whom 19 had a follow-up blood draw at the end of 6-month anti-TB treatment. The leading single serodiagnostic markers to differentiate between the presence or absence of active TB were anti-16 kDa IgA, anti-MPT64 IgA with sensitivity and specificity of 90%/90% and 95%/90%, respectively. The combined use of 3 or 4 antibodies further improved this performance to accuracies above 95%. After successful completion of anti-TB treatment at month 6, the levels of 16 kDa IgA and 16 kDa IgM dropped significantly whereas LAM IgG and TB-LTBI IgG increased. These results show the potential of extending investigation of anti-tuberculous IgG responses to include IgM and IgA responses against selected protein and non-protein antigens in differentiating active TB from other respiratory diseases in TB endemic settings. PMID:28415587

  12. Detection of a combination of serum IgG and IgA antibodies against selected mycobacterial targets provides promising diagnostic signatures for active TB.

    PubMed

    Awoniyi, Dolapo O; Baumann, Ralf; Chegou, Novel N; Kriel, Belinda; Jacobs, Ruschca; Kidd, Martin; Loxton, Andre G; Kaempfer, Susanne; Singh, Mahavir; Walzl, Gerhard

    2017-06-06

    Immunoglobulin G (IgG) based tests for the diagnosis of active tuberculosis (TB) disease often show a lack of specificity in TB endemic regions, which is mainly due to a high background prevalence of LTBI. Here, we investigated the combined performance of the responses of different Ig classes to selected mycobacterial antigens in primary healthcare clinic attendees with signs and symptoms suggestive of TB. The sensitivity and specificity of IgA, IgG and/or IgM to LAM and 7 mycobacterial protein antigens (ESAT-6, Tpx, PstS1, AlaDH, MPT64, 16kDa and 19kDa) and 2 antigen combinations (TUB, TB-LTBI) in the plasma of 63 individuals who underwent diagnostic work-up for TB after presenting with symptoms and signs compatible with possible active TB were evaluated. Active TB was excluded in 42 individuals of whom 21 has LTBI whereas active TB was confirmed in 21 patients of whom 19 had a follow-up blood draw at the end of 6-month anti-TB treatment. The leading single serodiagnostic markers to differentiate between the presence or absence of active TB were anti-16 kDa IgA, anti-MPT64 IgA with sensitivity and specificity of 90%/90% and 95%/90%, respectively. The combined use of 3 or 4 antibodies further improved this performance to accuracies above 95%. After successful completion of anti-TB treatment at month 6, the levels of 16 kDa IgA and 16 kDa IgM dropped significantly whereas LAM IgG and TB-LTBI IgG increased. These results show the potential of extending investigation of anti-tuberculous IgG responses to include IgM and IgA responses against selected protein and non-protein antigens in differentiating active TB from other respiratory diseases in TB endemic settings.

  13. Machine Learning Interface for Medical Image Analysis.

    PubMed

    Zhang, Yi C; Kagen, Alexander C

    2017-10-01

    TensorFlow is a second-generation open-source machine learning software library with a built-in framework for implementing neural networks in wide variety of perceptual tasks. Although TensorFlow usage is well established with computer vision datasets, the TensorFlow interface with DICOM formats for medical imaging remains to be established. Our goal is to extend the TensorFlow API to accept raw DICOM images as input; 1513 DaTscan DICOM images were obtained from the Parkinson's Progression Markers Initiative (PPMI) database. DICOM pixel intensities were extracted and shaped into tensors, or n-dimensional arrays, to populate the training, validation, and test input datasets for machine learning. A simple neural network was constructed in TensorFlow to classify images into normal or Parkinson's disease groups. Training was executed over 1000 iterations for each cross-validation set. The gradient descent optimization and Adagrad optimization algorithms were used to minimize cross-entropy between the predicted and ground-truth labels. Cross-validation was performed ten times to produce a mean accuracy of 0.938 ± 0.047 (95 % CI 0.908-0.967). The mean sensitivity was 0.974 ± 0.043 (95 % CI 0.947-1.00) and mean specificity was 0.822 ± 0.207 (95 % CI 0.694-0.950). We extended the TensorFlow API to enable DICOM compatibility in the context of DaTscan image analysis. We implemented a neural network classifier that produces diagnostic accuracies on par with excellent results from previous machine learning models. These results indicate the potential role of TensorFlow as a useful adjunct diagnostic tool in the clinical setting.

  14. Diagnostic accuracy of routine blood examinations and CSF lactate level for post-neurosurgical bacterial meningitis.

    PubMed

    Zhang, Yang; Xiao, Xiong; Zhang, Junting; Gao, Zhixian; Ji, Nan; Zhang, Liwei

    2017-06-01

    To evaluate the diagnostic accuracy of routine blood examinations and Cerebrospinal Fluid (CSF) lactate level for Post-neurosurgical Bacterial Meningitis (PBM) at a large sample-size of post-neurosurgical patients. The diagnostic accuracies of routine blood examinations and CSF lactate level to distinguish between PAM and PBM were evaluated with the values of the Area Under the Curve of the Receiver Operating Characteristic (AUC -ROC ) by retrospectively analyzing the datasets of post-neurosurgical patients in the clinical information databases. The diagnostic accuracy of routine blood examinations was relatively low (AUC -ROC <0.7). The CSF lactate level achieved rather high diagnostic accuracy (AUC -ROC =0.891; CI 95%, 0.852-0.922). The variables of patient age, operation duration, surgical diagnosis and postoperative days (the interval days between the neurosurgery and examinations) were shown to affect the diagnostic accuracy of these examinations. The variables were integrated with routine blood examinations and CSF lactate level by Fisher discriminant analysis to improve their diagnostic accuracy. As a result, the diagnostic accuracy of blood examinations and CSF lactate level was significantly improved with an AUC -ROC value=0.760 (CI 95%, 0.737-0.782) and 0.921 (CI 95%, 0.887-0.948) respectively. The PBM diagnostic accuracy of routine blood examinations was relatively low, whereas the accuracy of CSF lactate level was high. Some variables that are involved in the incidence of PBM can also affect the diagnostic accuracy for PBM. Taking into account the effects of these variables significantly improves the diagnostic accuracies of routine blood examinations and CSF lactate level. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Convergent Validity of the Autism Spectrum Disorders-Diagnostic Adult (ASD-DA) with the Pervasive Developmental Disorder/Autism Subscale of the Diagnostic Assessment for the Severely Handicapped-II (DASH-II)

    ERIC Educational Resources Information Center

    Belva, Brian C.; Matson, Johnny L.; Hattier, Megan A.; Kozlowski, Allison M.; Bamburg, Jay W.

    2012-01-01

    The "Autism Spectrum Disorders-Diagnosis for Adults" ("ASD-DA") is a standardized assessment used to measure autistic symptomatology in adults with intellectual disabilities (ID). In order to further establish the validity of this measure, convergent validity of the "ASD-DA" was established by comparing…

  16. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.

    PubMed

    McInnes, Matthew D F; Moher, David; Thombs, Brett D; McGrath, Trevor A; Bossuyt, Patrick M; Clifford, Tammy; Cohen, Jérémie F; Deeks, Jonathan J; Gatsonis, Constantine; Hooft, Lotty; Hunt, Harriet A; Hyde, Christopher J; Korevaar, Daniël A; Leeflang, Mariska M G; Macaskill, Petra; Reitsma, Johannes B; Rodin, Rachel; Rutjes, Anne W S; Salameh, Jean-Paul; Stevens, Adrienne; Takwoingi, Yemisi; Tonelli, Marcello; Weeks, Laura; Whiting, Penny; Willis, Brian H

    2018-01-23

    Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. The 27-item PRISMA diagnostic test accuracy checklist provides specific guidance for reporting of systematic reviews. The PRISMA diagnostic test accuracy guideline can facilitate the transparent reporting of reviews, and may assist in the evaluation of validity and applicability, enhance replicability of reviews, and make the results from systematic reviews of diagnostic test accuracy studies more useful.

  17. STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies.

    PubMed

    Bossuyt, Patrick M; Reitsma, Johannes B; Bruns, David E; Gatsonis, Constantine A; Glasziou, Paul P; Irwig, Les; Lijmer, Jeroen G; Moher, David; Rennie, Drummond; de Vet, Henrica C W; Kressel, Herbert Y; Rifai, Nader; Golub, Robert M; Altman, Douglas G; Hooft, Lotty; Korevaar, Daniël A; Cohen, Jérémie F

    2015-12-01

    Incomplete reporting has been identified as a major source of avoidable waste in biomedical research. Essential information is often not provided in study reports, impeding the identification, critical appraisal, and replication of studies. To improve the quality of reporting of diagnostic accuracy studies, the Standards for Reporting of Diagnostic Accuracy Studies (STARD) statement was developed. Here we present STARD 2015, an updated list of 30 essential items that should be included in every report of a diagnostic accuracy study. This update incorporates recent evidence about sources of bias and variability in diagnostic accuracy and is intended to facilitate the use of STARD. As such, STARD 2015 may help to improve completeness and transparency in reporting of diagnostic accuracy studies.

  18. Assessing clinical reasoning (ASCLIRE): Instrument development and validation.

    PubMed

    Kunina-Habenicht, Olga; Hautz, Wolf E; Knigge, Michel; Spies, Claudia; Ahlers, Olaf

    2015-12-01

    Clinical reasoning is an essential competency in medical education. This study aimed at developing and validating a test to assess diagnostic accuracy, collected information, and diagnostic decision time in clinical reasoning. A norm-referenced computer-based test for the assessment of clinical reasoning (ASCLIRE) was developed, integrating the entire clinical decision process. In a cross-sectional study participants were asked to choose as many diagnostic measures as they deemed necessary to diagnose the underlying disease of six different cases with acute or sub-acute dyspnea and provide a diagnosis. 283 students and 20 content experts participated. In addition to diagnostic accuracy, respective decision time and number of used relevant diagnostic measures were documented as distinct performance indicators. The empirical structure of the test was investigated using a structural equation modeling approach. Experts showed higher accuracy rates and lower decision times than students. In a cross-sectional comparison, the diagnostic accuracy of students improved with the year of study. Wrong diagnoses provided by our sample were comparable to wrong diagnoses in practice. We found an excellent fit for a model with three latent factors-diagnostic accuracy, decision time, and choice of relevant diagnostic information-with diagnostic accuracy showing no significant correlation with decision time. ASCLIRE considers decision time as an important performance indicator beneath diagnostic accuracy and provides evidence that clinical reasoning is a complex ability comprising diagnostic accuracy, decision time, and choice of relevant diagnostic information as three partly correlated but still distinct aspects.

  19. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    PubMed

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  20. A systematic review of the PTSD Checklist's diagnostic accuracy studies using QUADAS.

    PubMed

    McDonald, Scott D; Brown, Whitney L; Benesek, John P; Calhoun, Patrick S

    2015-09-01

    Despite the popularity of the PTSD Checklist (PCL) as a clinical screening test, there has been no comprehensive quality review of studies evaluating its diagnostic accuracy. A systematic quality assessment of 22 diagnostic accuracy studies of the English-language PCL using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) assessment tool was conducted to examine (a) the quality of diagnostic accuracy studies of the PCL, and (b) whether quality has improved since the 2003 STAndards for the Reporting of Diagnostic accuracy studies (STARD) initiative regarding reporting guidelines for diagnostic accuracy studies. Three raters independently applied the QUADAS tool to each study, and a consensus among the 4 authors is reported. Findings indicated that although studies generally met standards in several quality areas, there is still room for improvement. Areas for improvement include establishing representativeness, adequately describing clinical and demographic characteristics of the sample, and presenting better descriptions of important aspects of test and reference standard execution. Only 2 studies met each of the 14 quality criteria. In addition, study quality has not appreciably improved since the publication of the STARD Statement in 2003. Recommendations for the improvement of diagnostic accuracy studies of the PCL are discussed. (c) 2015 APA, all rights reserved).

  1. STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies.

    PubMed

    Bossuyt, Patrick M; Reitsma, Johannes B; Bruns, David E; Gatsonis, Constantine A; Glasziou, Paul P; Irwig, Les; Lijmer, Jeroen G; Moher, David; Rennie, Drummond; de Vet, Henrica C W; Kressel, Herbert Y; Rifai, Nader; Golub, Robert M; Altman, Douglas G; Hooft, Lotty; Korevaar, Daniël A; Cohen, Jérémie F

    2015-12-01

    Incomplete reporting has been identified as a major source of avoidable waste in biomedical research. Essential information is often not provided in study reports, impeding the identification, critical appraisal, and replication of studies. To improve the quality of reporting of diagnostic accuracy studies, the Standards for Reporting of Diagnostic Accuracy Studies (STARD) statement was developed. Here we present STARD 2015, an updated list of 30 essential items that should be included in every report of a diagnostic accuracy study. This update incorporates recent evidence about sources of bias and variability in diagnostic accuracy and is intended to facilitate the use of STARD. As such, STARD 2015 may help to improve completeness and transparency in reporting of diagnostic accuracy studies. © 2015 American Association for Clinical Chemistry.

  2. BRIEF REPORT: Beyond Clinical Experience: Features of Data Collection and Interpretation That Contribute to Diagnostic Accuracy

    PubMed Central

    Nendaz, Mathieu R; Gut, Anne M; Perrier, Arnaud; Louis-Simonet, Martine; Blondon-Choa, Katherine; Herrmann, François R; Junod, Alain F; Vu, Nu V

    2006-01-01

    BACKGROUND Clinical experience, features of data collection process, or both, affect diagnostic accuracy, but their respective role is unclear. OBJECTIVE, DESIGN Prospective, observational study, to determine the respective contribution of clinical experience and data collection features to diagnostic accuracy. METHODS Six Internists, 6 second year internal medicine residents, and 6 senior medical students worked up the same 7 cases with a standardized patient. Each encounter was audiotaped and immediately assessed by the subjects who indicated the reasons underlying their data collection. We analyzed the encounters according to diagnostic accuracy, information collected, organ systems explored, diagnoses evaluated, and final decisions made, and we determined predictors of diagnostic accuracy by logistic regression models. RESULTS Several features significantly predicted diagnostic accuracy after correction for clinical experience: early exploration of correct diagnosis (odds ratio [OR] 24.35) or of relevant diagnostic hypotheses (OR 2.22) to frame clinical data collection, larger number of diagnostic hypotheses evaluated (OR 1.08), and collection of relevant clinical data (OR 1.19). CONCLUSION Some features of data collection and interpretation are related to diagnostic accuracy beyond clinical experience and should be explicitly included in clinical training and modeled by clinical teachers. Thoroughness in data collection should not be considered a privileged way to diagnostic success. PMID:17105525

  3. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel ‘V-plot’ methodology to display accuracy values

    PubMed Central

    Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424

  4. Effects of aging and divided attention on episodic feeling-of-knowing accuracy.

    PubMed

    Sacher, Mathilde; Isingrini, Michel; Taconnat, Laurence

    2013-10-01

    This research investigated the effect of aging on episodic feeling-of-knowing (FOK) using a divided attention (DA) paradigm in order to examine whether DA in younger adults mimics the effects of aging when decreasing either memory encoding or monitoring processes. To that end, four groups of participants were tested on the FOK task: young adults (control group), young adults under DA at encoding, young adults under DA when making FOK judgments, and older adults. Our results showed that DA at encoding in young adults mimicked the effect of aging on memory performance, and also on FOK magnitude and accuracy, supporting the memory-constraint hypothesis (Hertzog et al., 2010). However, our results do not completely contradict the monitoring-deficit hypothesis, as DA during FOK judgments also affected FOK accuracy, but to a lesser extent than the aging effect or DA during encoding. We suggest that the age-related FOK deficit may be due to a lower level of deep encoding, leading to difficulty retrieving target-related contextual details enabling accurate prediction of subsequent recognition. © 2013.

  5. Evaluation of the accuracy of Demirjian method for estimation of dental age among 6-12 years of children in Navi Mumbai: A radiographic study.

    PubMed

    Hegde, Rahul J; Khare, Sumedh Suhas; Saraf, Tanvi A; Trivedi, Sonal; Naidu, Sonal

    2015-01-01

    Dental formation is superior to eruption as a method of dental age (DA) assessment. Eruption is only a brief occurrence, whereas formation may be related at different chronologic age levels, thereby providing a precise index for determining DA. The study was designed to determine the nature of inter-relationship between chronologic and DA. Age estimation depending upon tooth formation was done by Demirjian method and accuracy of Demirjian method was also evaluated. The sample for the study consisted of 197 children of Navi Mumbai. Significant positive correlation was found between chronologic age and DA that is, (r = 0.995), (P < 0.0001) for boys and (r = 0.995), (P < 0.0001) for girls. When age estimation was done by Demirjian method, mean the difference between true age (chronologic age) and assessed (DA) was 2 days for boys and 37 days for girls. Demirjian method showed high accuracy when applied to Navi Mumbai (Maharashtra - India) population. Demirjian method showed high accuracy when applied to Navi Mumbai (Maharashtra - India) population.

  6. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity.

    PubMed

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M; Schlattmann, Peter; Dewey, Marc

    2013-06-01

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item ("Uninterpretable Results") showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with "no fulfilment" increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. • Good methodological quality is a basic requirement in diagnostic accuracy studies. • Most coronary CT angiography studies have only been of moderate design quality. • Weak methodological quality will affect the sensitivity and specificity. • No improvement in methodological quality was observed over time. • Authors should consider the QUADAS checklist when undertaking accuracy studies.

  7. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  8. Exploring "DIALANG'S" Diagnostic Feedback in Online L2 Dynamic Assessment

    ERIC Educational Resources Information Center

    Ebadi, Saman

    2016-01-01

    Dynamic assessment (DA) as an alternative to psychometric-based testing focuses on the collaborative dialogue between the learners and the mediator to move the learners from their current capabilities. This study represents a web-based qualitative inquiry in online DA which aims at addressing the inadequacy of the diagnostic feedback of the…

  9. Computer-Aided Medical Diagnosis. Literature Review

    DTIC Science & Technology

    1978-12-15

    Croft found a 13% difference in diagnostic accuracy. He considered this difference insignificant in relation to the diagnostic differences caused ...type of diseases diagnosed probably are the major cause of cross-study variability in diagnostic accuracy. The consistency of diagnostic accuracy...REFERENCES ALPEROVITCH, A. and FRAGU, P., A suggestion for an effective use of a computer-aided diagnosis system in screening for hyperthyroidism , Method

  10. Findings, phenotypes, and outcomes in Freeman-Sheldon and Sheldon-Hall syndromes and distal arthrogryposis types 1 and 3: protocol for systematic review and patient-level data meta-analysis.

    PubMed

    Poling, Mikaela I; Morales Corado, José Andrés; Chamberlain, Robert L

    2017-03-06

    Freeman-Sheldon and Sheldon-Hall syndromes (FSS and SHS) and distal arthrogryposis types 1 and 3 (DA1 and DA3) are rare, often confused, congenital syndromes. Few studies exist. With reported diagnosis unreliable, it would be scientifically inappropriate to consider articles describing FSS, SHS, DA1, or DA3, unless diagnoses were independently verified, rendering conventional systematic review and meta-analysis methodology inappropriate and necessitating patient-level data analysis (PROSPERO: CRD42015024740). As part of a clinical practise guideline development process, we evaluate (1) diagnostic accuracy from 1938-2017, using the Stevenson criteria; (2) the most common physical findings, possible frequency clusters, and complications of physical findings amongst patients with FSS; and (3) treatment types and outcomes. All papers reporting diagnosis of FSS, SHS, DA1, and DA3 are included in searching PubMed and Google Scholar from December 2014 to July 2015 and again before final analyses. Patients with FSS are divided into four phenotype-defined sub-types; all patients are grouped by published diagnosis and medical speciality. Significance of physical findings and historical data is evaluated by chi-square. Associations of physical findings and history with diagnosis and treatment outcome are evaluated by Pearson correlation and linear regression analysis. Two-tailed alpha level of 0.05 is used throughout. The need for detailed patient-level data extraction may limit the types of articles included and questions able to be answered. For treatment and psychosocial health outcomes, we anticipate enhanced difficulties, which may limit significance, power, and results' usability. We hope to outline knowledge gaps and prioritise areas for clinical investigation. CRD42015024740 Universal Trial Number: U1111-1172-4670.

  11. Systematic Review and Meta-Analysis of Studies Evaluating Diagnostic Test Accuracy: A Practical Review for Clinical Researchers-Part II. Statistical Methods of Meta-Analysis

    PubMed Central

    Lee, Juneyoung; Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies. PMID:26576107

  12. Th1/Th2 balance and humoral immune response to potential antigens as early diagnostic method of equine Strongylus nematode infection.

    PubMed

    Abo-Aziza, Faten A M; Hendawy, Seham H M; Namaky, Amira H El; Ashry, Heba M

    2017-06-01

    The aim of this study was to investigate the early diagnosis of strongyle infection based on early changes in Th1 and Th2 cytokines beside the diagnostic accuracy values and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and western blotting profiles using prepared strongyles antigens. A total of 73 donkeys had a mean age of 4-32 years old were parasitologically examined for strongyle infection. The early changes in Th1 and Th2 cytokines were determined, and the diagnostic accuracy values and SDS-PAGE and western blotting profiles were performed using prepared strongyles antigens; crude somatic Strongylus vulgaris (CSS), excretory-secretory S. vulgaris (ESS), crude somatic Cyathostomins (CSC), and excretory-secretory Cyathostomins (ESC). The results revealed highest 437.04% and lowest 37.81% immunoglobulin G (IgG) in high and low egg shedder groups when using ESC and CSS antigens, respectively. Antibodies index for ESS and CSC were significantly higher in moderate egg shedder group while that for ESS and CSC, ESC was significantly higher in high egg shedder group. Tumor necrosis factor alpha (TNF-α)/interleukin-4 (IL-4) balance in S. vulgaris infected donkeys was approximately equal in apparently healthy, low and high egg shedder groups while TNF-α < IL-4 in moderate egg shedder. In Cyathostomins infected animals, TNF-α/IL-4 balance was approximately equal in apparently healthy group while it was low in moderate and high egg shedder groups. The diagnostic accuracy showed that the higher specificity (46.6%) and prevalence (95.40%) were recorded by CSS and ESC antigens, respectively. However, SDS-PAGE and western blotting profiling proved that the band at molecular weight 25 kDa is exhibited by CSS antigen. Combination of detecting level of TNF-α/IL-4 balance, CSS antigen and IgG concentration is good tool for appropriate diagnosis of such infection. More advancement research must be done concerning Th1/Th2 balance and cross-reactivity of S. vulgaris and Cyathostomins spp. at the base of serological and molecular investigation.

  13. Th1/Th2 balance and humoral immune response to potential antigens as early diagnostic method of equine Strongylus nematode infection

    PubMed Central

    Abo-Aziza, Faten A. M.; Hendawy, Seham H. M.; Namaky, Amira H. El; Ashry, Heba M.

    2017-01-01

    Aim:: The aim of this study was to investigate the early diagnosis of strongyle infection based on early changes in Th1 and Th2 cytokines beside the diagnostic accuracy values and sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and western blotting profiles using prepared strongyles antigens. Materials and Methods:: A total of 73 donkeys had a mean age of 4-32 years old were parasitologically examined for strongyle infection. The early changes in Th1 and Th2 cytokines were determined, and the diagnostic accuracy values and SDS-PAGE and western blotting profiles were performed using prepared strongyles antigens; crude somatic Strongylus vulgaris (CSS), excretory-secretory S. vulgaris (ESS), crude somatic Cyathostomins (CSC), and excretory-secretory Cyathostomins (ESC). Results:: The results revealed highest 437.04% and lowest 37.81% immunoglobulin G (IgG) in high and low egg shedder groups when using ESC and CSS antigens, respectively. Antibodies index for ESS and CSC were significantly higher in moderate egg shedder group while that for ESS and CSC, ESC was significantly higher in high egg shedder group. Tumor necrosis factor alpha (TNF-α)/interleukin-4 (IL-4) balance in S. vulgaris infected donkeys was approximately equal in apparently healthy, low and high egg shedder groups while TNF-α < IL-4 in moderate egg shedder. In Cyathostomins infected animals, TNF-α/IL-4 balance was approximately equal in apparently healthy group while it was low in moderate and high egg shedder groups. The diagnostic accuracy showed that the higher specificity (46.6%) and prevalence (95.40%) were recorded by CSS and ESC antigens, respectively. However, SDS-PAGE and western blotting profiling proved that the band at molecular weight 25 kDa is exhibited by CSS antigen. Conclusion:: Combination of detecting level of TNF-α/IL-4 balance, CSS antigen and IgG concentration is good tool for appropriate diagnosis of such infection. More advancement research must be done concerning Th1/Th2 balance and cross-reactivity of S. vulgaris and Cyathostomins spp. at the base of serological and molecular investigation. PMID:28717322

  14. The STARD statement for reporting diagnostic accuracy studies: application to the history and physical examination.

    PubMed

    Simel, David L; Rennie, Drummond; Bossuyt, Patrick M M

    2008-06-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement provided guidelines for investigators conducting diagnostic accuracy studies. We reviewed each item in the statement for its applicability to clinical examination diagnostic accuracy research, viewing each discrete aspect of the history and physical examination as a diagnostic test. Nonsystematic review of the STARD statement. Two former STARD Group participants and 1 editor of a journal series on clinical examination research reviewed each STARD item. Suggested interpretations and comments were shared to develop consensus. The STARD Statement applies generally well to clinical examination diagnostic accuracy studies. Three items are the most important for clinical examination diagnostic accuracy studies, and investigators should pay particular attention to their requirements: describe carefully the patient recruitment process, describe participant sampling and address if patients were from a consecutive series, and describe whether the clinicians were masked to the reference standard tests and whether the interpretation of the reference standard test was masked to the clinical examination components or overall clinical impression. The consideration of these and the other STARD items in clinical examination diagnostic research studies would improve the quality of investigations and strengthen conclusions reached by practicing clinicians. The STARD statement provides a very useful framework for diagnostic accuracy studies. The group correctly anticipated that there would be nuances applicable to studies of the clinical examination. We offer guidance that should enhance their usefulness to investigators embarking on original studies of a patient's history and physical examination.

  15. The role of computerized diagnostic proposals in the interpretation of the 12-lead electrocardiogram by cardiology and non-cardiology fellows.

    PubMed

    Novotny, Tomas; Bond, Raymond; Andrsova, Irena; Koc, Lumir; Sisakova, Martina; Finlay, Dewar; Guldenring, Daniel; Spinar, Jindrich; Malik, Marek

    2017-05-01

    Most contemporary 12-lead electrocardiogram (ECG) devices offer computerized diagnostic proposals. The reliability of these automated diagnoses is limited. It has been suggested that incorrect computer advice can influence physician decision-making. This study analyzed the role of diagnostic proposals in the decision process by a group of fellows of cardiology and other internal medicine subspecialties. A set of 100 clinical 12-lead ECG tracings was selected covering both normal cases and common abnormalities. A team of 15 junior Cardiology Fellows and 15 Non-Cardiology Fellows interpreted the ECGs in 3 phases: without any diagnostic proposal, with a single diagnostic proposal (half of them intentionally incorrect), and with four diagnostic proposals (only one of them being correct) for each ECG. Self-rated confidence of each interpretation was collected. Availability of diagnostic proposals significantly increased the diagnostic accuracy (p<0.001). Nevertheless, in case of a single proposal (either correct or incorrect) the increase of accuracy was present in interpretations with correct diagnostic proposals, while the accuracy was substantially reduced with incorrect proposals. Confidence levels poorly correlated with interpretation scores (rho≈2, p<0.001). Logistic regression showed that an interpreter is most likely to be correct when the ECG offers a correct diagnostic proposal (OR=10.87) or multiple proposals (OR=4.43). Diagnostic proposals affect the diagnostic accuracy of ECG interpretations. The accuracy is significantly influenced especially when a single diagnostic proposal (either correct or incorrect) is provided. The study suggests that the presentation of multiple computerized diagnoses is likely to improve the diagnostic accuracy of interpreters. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.

    PubMed

    Richter, Grace M; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Chopra, Vikas; Greenfield, David S; Varma, Rohit; Schuman, Joel S; Huang, David

    2016-08-01

    To report diagnostic accuracy of optical coherence tomography (OCT) disc variables using both time-domain (TD) and Fourier-domain (FD) OCT, and to improve the use of OCT disc variable measurements for glaucoma diagnosis through regression analyses that adjust for optic disc size and axial length-based magnification error. Observational, cross-sectional. In total, 180 normal eyes of 112 participants and 180 eyes of 138 participants with perimetric glaucoma from the Advanced Imaging for Glaucoma Study. Diagnostic variables evaluated from TD-OCT and FD-OCT were: disc area, rim area, rim volume, optic nerve head volume, vertical cup-to-disc ratio (CDR), and horizontal CDR. These were compared with overall retinal nerve fiber layer thickness and ganglion cell complex. Regression analyses were performed that corrected for optic disc size and axial length. Area-under-receiver-operating curves (AUROC) were used to assess diagnostic accuracy before and after the adjustments. An index based on multiple logistic regression that combined optic disc variables with axial length was also explored with the aim of improving diagnostic accuracy of disc variables. Comparison of diagnostic accuracy of disc variables, as measured by AUROC. The unadjusted disc variables with the highest diagnostic accuracies were: rim volume for TD-OCT (AUROC=0.864) and vertical CDR (AUROC=0.874) for FD-OCT. Magnification correction significantly worsened diagnostic accuracy for rim variables, and while optic disc size adjustments partially restored diagnostic accuracy, the adjusted AUROCs were still lower. Axial length adjustments to disc variables in the form of multiple logistic regression indices led to a slight but insignificant improvement in diagnostic accuracy. Our various regression approaches were not able to significantly improve disc-based OCT glaucoma diagnosis. However, disc rim area and vertical CDR had very high diagnostic accuracy, and these disc variables can serve to complement additional OCT measurements for diagnosis of glaucoma.

  17. An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

    PubMed

    Obuchowski, Nancy A

    2006-02-15

    ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.

  18. Diagnostic Sensitivity and Specificity of Dark Adaptometry for Detection of Age-Related Macular Degeneration

    PubMed Central

    Jackson, Gregory R.; Scott, Ingrid U.; Kim, Ivana K.; Quillen, David A.; Iannaccone, Alessandro; Edwards, John G.

    2014-01-01

    Purpose. Difficulty with night vision is a common complaint of patients with age-related macular degeneration (AMD). Consistent with this complaint, dark adaptation (DA) is substantially impaired in these patients. Because of the severity of the deficit, measurement of DA has been suggested as a means for the diagnosis of AMD. Previous methods for measurement of DA were time intensive (>30 minutes), which made them unsuitable for clinical use. This study evaluated a rapid DA test (≤6.5 minutes) for the detection of AMD. Methods. Dark adaptation was measured by using the AdaptDx dark adaptometer in two groups: subjects with normal retinal health and subjects with AMD. Subjects were assigned to their group by clinical examination and grading of fundus photographs. Subjects were classified as having DA consistent with normal retinal health (rod intercept ≤ 6.5 minutes) or having dark adaptation consistent with AMD (rod intercept > 6.5 minutes). Results. The eligible sample for analysis included 21 normal adults and 127 AMD patients. The rapid test was found to have a diagnostic sensitivity of 90.6% (P < 0.001) and specificity of 90.5% (P < 0.027). Thus, abnormal DA was detected in 115 of 127 AMD patients, and normal DA was found in 19 of 21 normal adults. Conclusions. The high diagnostic sensitivity and specificity compared favorably to long-duration research methods for the measurement of DA, and slit lamp biomicroscopy performed by a retina specialist. These results suggest that a rapid DA test is useful for the detection of AMD. PMID:24550363

  19. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease.

    PubMed

    Matías-Guiu, Jordi A; Valles-Salgado, María; Rognoni, Teresa; Hamre-Gil, Frank; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Our aim was to evaluate and compare the diagnostic properties of 5 screening tests for the diagnosis of mild Alzheimer disease (AD). We conducted a prospective and cross-sectional study of 92 patients with mild AD and of 68 healthy controls from our Department of Neurology. The diagnostic properties of the following tests were compared: Mini-Mental State Examination (MMSE), Addenbrooke's Cognitive Examination III (ACE-III), Memory Impairment Screen (MIS), Montreal Cognitive Assessment (MoCA), and Rowland Universal Dementia Assessment Scale (RUDAS). All tests yielded high diagnostic accuracy, with the ACE-III achieving the best diagnostic properties. The area under the curve was 0.897 for the ACE-III, 0.889 for the RUDAS, 0.874 for the MMSE, 0.866 for the MIS, and 0.856 for the MoCA. The Mini-ACE score from the ACE-III showed the highest diagnostic capacity (area under the curve 0.939). Memory scores of the ACE-III and of the RUDAS showed a better diagnostic accuracy than those of the MMSE and of the MoCA. All tests, especially the ACE-III, conveyed a higher diagnostic accuracy in patients with full primary education than in the less educated group. Implementing normative data improved the diagnostic accuracy of the ACE-III but not that of the other tests. The ACE-III achieved the highest diagnostic accuracy. This better discrimination was more evident in the more educated group. © 2017 S. Karger AG, Basel.

  20. Using Meta-Analysis to Inform the Design of Subsequent Studies of Diagnostic Test Accuracy

    ERIC Educational Resources Information Center

    Hinchliffe, Sally R.; Crowther, Michael J.; Phillips, Robert S.; Sutton, Alex J.

    2013-01-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial…

  1. STARD 2015 guidelines for reporting diagnostic accuracy studies: explanation and elaboration

    PubMed Central

    Cohen, Jérémie F; Korevaar, Daniël A; Altman, Douglas G; Bruns, David E; Gatsonis, Constantine A; Hooft, Lotty; Irwig, Les; Levine, Deborah; Reitsma, Johannes B; de Vet, Henrica C W; Bossuyt, Patrick M M

    2016-01-01

    Diagnostic accuracy studies are, like other clinical studies, at risk of bias due to shortcomings in design and conduct, and the results of a diagnostic accuracy study may not apply to other patient groups and settings. Readers of study reports need to be informed about study design and conduct, in sufficient detail to judge the trustworthiness and applicability of the study findings. The STARD statement (Standards for Reporting of Diagnostic Accuracy Studies) was developed to improve the completeness and transparency of reports of diagnostic accuracy studies. STARD contains a list of essential items that can be used as a checklist, by authors, reviewers and other readers, to ensure that a report of a diagnostic accuracy study contains the necessary information. STARD was recently updated. All updated STARD materials, including the checklist, are available at http://www.equator-network.org/reporting-guidelines/stard. Here, we present the STARD 2015 explanation and elaboration document. Through commented examples of appropriate reporting, we clarify the rationale for each of the 30 items on the STARD 2015 checklist, and describe what is expected from authors in developing sufficiently informative study reports. PMID:28137831

  2. [Diagnostic value of cardiac magnetic resonance in patients with acute viral myocarditis].

    PubMed

    Ouyang, Haichun; Chen, Haixiong; Hu, Yunzhao; Wu, Yanxian; Li, Wensheng; Chen, Yuying; Cen, Yujian

    2014-11-01

    To assess the diagnostic value of cardiac magnetic resonance (CMR) in patients with acute viral myocarditis. Thirty patients with suspected acute viral myocarditis admitted in first people's hospital of Shunde from June 2011 to June 2013 were included in this prospective study. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of acute viral myocarditis were evaluated by clinical diagnosis. Diagnostic value among different scan methods and Lake Louise criteria were compared. Acute viral myocarditis was diagnosed in 63.33% (19/30) patients.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 57.89%, 72.73%, 78.57%, 50.00%, 63.33%, respectively by edema imaging (ER).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 63.64%, 78.95%, 63.64%, 73.33%, respectively using global relative enhancement (gRE).Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 78.95%, 54.55%, 75.00%, 60.00%, 70.00%, respectively using late gadolinium enhancement (LGE) criteria.Values for sensitivity, specificity, PPV, NPV, and diagnostic accuracy within the overall cohort were 84.21%, 81.82%, 88.89%, 75.00%, 83.33% using Lake Louise criteria. The sensitivity, specificity, PPV, NPV, and diagnostic accuracy using Lake Louise criteria were significantly higher than using ER, gRE, LGE alone(all P < 0.05).Specificity was higher using ER than using gRE and LGE (both P < 0.05). The sensitivity, NPV, and diagnostic accuracy were significantly higher using gRE than using ER (all P < 0.05) and was similar as using LGE (all P > 0.05). Cardiac magnetic resonance is an excellent imaging modality for the diagnosis of acute viral myocarditis.

  3. The STARD Statement for Reporting Diagnostic Accuracy Studies: Application to the History and Physical Examination

    PubMed Central

    Rennie, Drummond; Bossuyt, Patrick M. M.

    2008-01-01

    Summary Objective The Standards for Reporting of Diagnostic Accuracy (STARD) statement provided guidelines for investigators conducting diagnostic accuracy studies. We reviewed each item in the statement for its applicability to clinical examination diagnostic accuracy research, viewing each discrete aspect of the history and physical examination as a diagnostic test. Setting Nonsystematic review of the STARD statement. Interventions Two former STARD Group participants and 1 editor of a journal series on clinical examination research reviewed each STARD item. Suggested interpretations and comments were shared to develop consensus. Measurements and Main Results The STARD Statement applies generally well to clinical examination diagnostic accuracy studies. Three items are the most important for clinical examination diagnostic accuracy studies, and investigators should pay particular attention to their requirements: describe carefully the patient recruitment process, describe participant sampling and address if patients were from a consecutive series, and describe whether the clinicians were masked to the reference standard tests and whether the interpretation of the reference standard test was masked to the clinical examination components or overall clinical impression. The consideration of these and the other STARD items in clinical examination diagnostic research studies would improve the quality of investigations and strengthen conclusions reached by practicing clinicians. Conclusions The STARD statement provides a very useful framework for diagnostic accuracy studies. The group correctly anticipated that there would be nuances applicable to studies of the clinical examination. We offer guidance that should enhance their usefulness to investigators embarking on original studies of a patient’s history and physical examination. PMID:18347878

  4. Training and quality assurance with the Structured Clinical Interview for DSM-IV (SCID-I/P).

    PubMed

    Ventura, J; Liberman, R P; Green, M F; Shaner, A; Mintz, J

    1998-06-15

    Accuracy in psychiatric diagnosis is critical for evaluating the suitability of the subjects for entry into research protocols and for establishing comparability of findings across study sites. However, training programs in the use of diagnostic instruments for research projects are not well systematized. Furthermore, little information has been published on the maintenance of interrater reliability of diagnostic assessments. At the UCLA Research Center for Major Mental Illnesses, a Training and Quality Assurance Program for SCID interviewers was used to evaluate interrater reliability and diagnostic accuracy. Although clinically experienced interviewers achieved better interrater reliability and overall diagnostic accuracy than neophyte interviewers, both groups were able to achieve and maintain high levels of interrater reliability, diagnostic accuracy, and interviewer skill. At the first quality assurance check after training, there were no significant differences between experienced and neophyte interviewers in interrater reliability or diagnostic accuracy. Standardization of training and quality assurance procedures within and across research projects may make research findings from study sites more comparable.

  5. Systematic Review of the Diagnostic Accuracy and Therapeutic Effectiveness of Sacroiliac Joint Interventions.

    PubMed

    Simopoulos, Thomas T; Manchikanti, Laxmaiah; Gupta, Sanjeeva; Aydin, Steve M; Kim, Chong Hwan; Solanki, Daneshvari; Nampiaparampil, Devi E; Singh, Vijay; Staats, Peter S; Hirsch, Joshua A

    2015-01-01

    The sacroiliac joint is well known as a cause of low back and lower extremity pain. Prevalence estimates are 10% to 25% in patients with persistent axial low back pain without disc herniation, discogenic pain, or radiculitis based on multiple diagnostic studies and systematic reviews. However, at present there are no definitive management options for treating sacroiliac joint pain. To evaluate the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. A systematic review of the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. The available literature on diagnostic and therapeutic sacroiliac joint interventions was reviewed. The quality assessment criteria utilized were the Quality Appraisal of Reliability Studies (QAREL) checklist for diagnostic accuracy studies, Cochrane review criteria to assess sources of risk of bias, and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment (IPM-QRB) criteria for randomized therapeutic trials and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment for Nonrandomized Studies (IPM-QRBNR) for observational therapeutic assessments. The level of evidence was based on a best evidence synthesis with modified grading of qualitative evidence from Level I to Level V. Data sources included relevant literature published from 1966 through March 2015 that were identified through searches of PubMed and EMBASE, manual searches of the bibliographies of known primary and review articles, and all other sources. For the diagnostic accuracy assessment, and for the therapeutic modalities, the primary outcome measure of pain relief and improvement in functional status were utilized. A total of 11 diagnostic accuracy studies and 14 therapeutic studies were included. The evidence for diagnostic accuracy is Level II for dual diagnostic blocks with at least 70% pain relief as the criterion standard and Level III evidence for single diagnostic blocks with at least 75% pain relief as the criterion standard. The evidence for cooled radiofrequency neurotomy in managing sacroiliac joint pain is Level II to III. The evidence for conventional radiofrequency neurotomy, intraarticular steroid injections, and periarticular injections with steroids or botulinum toxin is limited: Level III or IV. The limitations of this systematic review include inconsistencies in diagnostic accuracy studies with a paucity of high quality, replicative, and consistent literature. The limitations for therapeutic interventions include variations in technique, variable diagnostic standards for inclusion criteria, and variable results. The evidence for the accuracy of diagnostic and therapeutic effectiveness of sacroiliac joint interventions varied from Level II to Level IV.

  6. Validity and Diagnostic Accuracy of Scores from the Autism Diagnostic Observation Schedule-Generic

    ERIC Educational Resources Information Center

    Reid, Melissa A.

    2012-01-01

    The purpose of this study was to examine the internal structure, relationships with other variables, and diagnostic accuracy of scores on the Autism Diagnostic Observation Schedule-Generic (ADOS-G; Lord et al., 1999) for the purpose of diagnostic decision-making. Participants were 462 children enrolled in a public school district in the southern…

  7. Diagnostic accuracy of histopathologic and cytopathologic examination of Aspergillus species.

    PubMed

    Shah, Akeesha A; Hazen, Kevin C

    2013-01-01

    To assess the diagnostic accuracy of histopatho-logic and cytopathologic examination (HCE) of Aspergillus species (spp), we performed an 11-year retrospective review to correlate surgical/cytology cases with a diagnosis of Aspergillus spp with their concurrent fungal culture results. Diagnostic accuracy was defined as the percentage of cases with culture-proven Aspergillus spp divided by the number of cases diagnosed as Aspergillus spp on HCE that had growth on fungal culture. Ninety surgical/cytology cases with concurrent fungal culture were reviewed, 58 of which grew a fungal organism. Of these 58 cases, 45 grew an Aspergillus spp, whereas 13 grew an organism other than Aspergillus spp, including both common (Scedosporium, Fusarium, and Paecilomyces spp) and uncommon mimickers (Trichosporon loubieri), resulting in a diagnostic accuracy of 78%. The low diagnostic accuracy indicates that several fungal organisms can morphologically mimic Aspergillus spp and can only be distinguished by fungal culture and DNA sequencing.

  8. Detailed Performance Assessment for the ITER ECE Diagnostic

    NASA Astrophysics Data System (ADS)

    Rowan, W.; Austin, M.; Houshmandyar, S.; Phillips, P.; Beno, J.; Bryant, A.; Ouroua, A.; Weeks, D.; Hubbard, A.; Taylor, G.

    2017-10-01

    One of the primary diagnostics for electron temperature (Te) measurement on ITER is based on the detection of electron cyclotron emission (ECE) Here we describe the predicted performance of the newly completed ECE diagnostic design by quantitatively following the emission from the plasma to the instruments and including the calibration method to assess accuracy. Operation of the diagnostic at 5.3 T is the main interest here but critical features of the emission spectra for 2.65 T and 1.8 T will be described. ECE will be collected by two very similar optical systems: one a radial view, the other an oblique view. Both measurements are used for Te while the oblique view also allows detection of non-thermal distortion in the electron distribution. An in-vacuum calibration source is included in the front end of each view to calibrate out the effect of any degradation of in-vessel optics. Following collection, the emission is split into orthogonal polarizations and transmitted to the detection instruments via waveguides filled with dry nitrogen, a choice that simplifies construction and analysis. Near the instruments, a switchyard is used to select which polarization and view is detected by each instrument. The design for the radiometer used for 5.3 T will be described in detail. Supported by PPPL/US-DA via subcontract S013464-H to UT Austin.

  9. Factors Determining the Inter-observer Variability and Diagnostic Accuracy of High-resolution Manometry for Esophageal Motility Disorders.

    PubMed

    Kim, Ji Hyun; Kim, Sung Eun; Cho, Yu Kyung; Lim, Chul-Hyun; Park, Moo In; Hwang, Jin Won; Jang, Jae-Sik; Oh, Minkyung

    2018-01-30

    Although high-resolution manometry (HRM) has the advantage of visual intuitiveness, its diagnostic validity remains under debate. The aim of this study was to evaluate the diagnostic accuracy of HRM for esophageal motility disorders. Six staff members and 8 trainees were recruited for the study. In total, 40 patients enrolled in manometry studies at 3 institutes were selected. Captured images of 10 representative swallows and a single swallow in analyzing mode in both high-resolution pressure topography (HRPT) and conventional line tracing formats were provided with calculated metrics. Assessments of esophageal motility disorders showed fair agreement for HRPT and moderate agreement for conventional line tracing (κ = 0.40 and 0.58, respectively). With the HRPT format, the k value was higher in category A (esophagogastric junction [EGJ] relaxation abnormality) than in categories B (major body peristalsis abnormalities with intact EGJ relaxation) and C (minor body peristalsis abnormalities or normal body peristalsis with intact EGJ relaxation). The overall exact diagnostic accuracy for the HRPT format was 58.8% and rater's position was an independent factor for exact diagnostic accuracy. The diagnostic accuracy for major disorders was 63.4% with the HRPT format. The frequency of major discrepancies was higher for category B disorders than for category A disorders (38.4% vs 15.4%; P < 0.001). The interpreter's experience significantly affected the exact diagnostic accuracy of HRM for esophageal motility disorders. The diagnostic accuracy for major disorders was higher for achalasia than distal esophageal spasm and jackhammer esophagus.

  10. Quality Assessment of Comparative Diagnostic Accuracy Studies: Our Experience Using a Modified Version of the QUADAS-2 Tool

    ERIC Educational Resources Information Center

    Wade, Ros; Corbett, Mark; Eastwood, Alison

    2013-01-01

    Assessing the quality of included studies is a vital step in undertaking a systematic review. The recently revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool (QUADAS-2), which is the only validated quality assessment tool for diagnostic accuracy studies, does not include specific criteria for assessing comparative studies. As…

  11. A Low-Molecular-Weight Ferroxidase Is Increased in the CSF of sCJD Cases: CSF Ferroxidase and Transferrin as Diagnostic Biomarkers for sCJD

    PubMed Central

    Haldar, Swati; Beveridge, ’Alim J.; Wong, Joseph; Singh, Ajay; Galimberti, Daniela; Borroni, Barbara; Zhu, Xiongwei; Blevins, Janis; Greenlee, Justin; Perry, George; Mukhopadhyay, Chinmay K.; Schmotzer, Christine

    2013-01-01

    Abstract Aims: Most biomarkers used for the premortem diagnosis of sporadic Creutzfeldt-Jakob disease (CJD) are surrogate in nature, and provide suboptimal sensitivity and specificity. Results: We report that CJD-associated brain iron dyshomeostasis is reflected in the cerebrospinal fluid (CSF), providing disease-specific diagnostic biomarkers. Analysis of 290 premortem CSF samples from confirmed cases of CJD, Alzheimer's disease, and other dementias (DMs), and 52 non-DM (ND) controls revealed a significant difference in ferroxidase (Frx) activity and transferrin (Tf) levels in sporadic Creutzfeldt-Jakob disease (sCJD) relative to other DM and ND controls. A combination of CSF Frx and Tf discriminated sCJD from other DMs with a sensitivity of 86.8%, specificity of 92.5%, accuracy of 88.9%, and area-under-the receiver-operating-characteristic (ROC) curve of 0.94. This combination provided a similar diagnostic accuracy in discriminating CJD from rapidly progressing cases who died within 6 months of sample collection. Surprisingly, ceruloplasmin and amyloid precursor protein, the major brain Frxs, displayed minimal activity in the CSF. Most of the Frx activity was concentrated in the <3-kDa fraction in normal and diseased CSF, and resisted heat and proteinase-K treatment. Innovation: (i) A combination of CSF Frx and Tf provides disease-specific premortem diagnostic biomarkers for sCJD. (ii) A novel, nonenzymatic, nonprotein Frx predominates in human CSF that is distinct from the currently known CSF Frxs. Conclusion: The underlying cause of iron imbalance is distinct in sCJD relative to other DMs associated with the brain iron imbalance. Thus, change in the CSF levels of iron-management proteins can provide disease-specific biomarkers and insight into the cause of iron imbalance in neurodegenerative conditions. Antioxid. Redox Signal. 19, 1662–1675. PMID:23379482

  12. Commercial tree species discrimination using airborne AISA Eagle hyperspectral imagery and partial least squares discriminant analysis (PLS-DA) in KwaZulu-Natal, South Africa

    NASA Astrophysics Data System (ADS)

    Peerbhay, Kabir Yunus; Mutanga, Onisimo; Ismail, Riyad

    2013-05-01

    Discriminating commercial tree species using hyperspectral remote sensing techniques is critical in monitoring the spatial distributions and compositions of commercial forests. However, issues related to data dimensionality and multicollinearity limit the successful application of the technology. The aim of this study was to examine the utility of the partial least squares discriminant analysis (PLS-DA) technique in accurately classifying six exotic commercial forest species (Eucalyptus grandis, Eucalyptus nitens, Eucalyptus smithii, Pinus patula, Pinus elliotii and Acacia mearnsii) using airborne AISA Eagle hyperspectral imagery (393-900 nm). Additionally, the variable importance in the projection (VIP) method was used to identify subsets of bands that could successfully discriminate the forest species. Results indicated that the PLS-DA model that used all the AISA Eagle bands (n = 230) produced an overall accuracy of 80.61% and a kappa value of 0.77, with user's and producer's accuracies ranging from 50% to 100%. In comparison, incorporating the optimal subset of VIP selected wavebands (n = 78) in the PLS-DA model resulted in an improved overall accuracy of 88.78% and a kappa value of 0.87, with user's and producer's accuracies ranging from 70% to 100%. Bands located predominantly within the visible region of the electromagnetic spectrum (393-723 nm) showed the most capability in terms of discriminating between the six commercial forest species. Overall, the research has demonstrated the potential of using PLS-DA for reducing the dimensionality of hyperspectral datasets as well as determining the optimal subset of bands to produce the highest classification accuracies.

  13. Efficient strategies to find diagnostic test accuracy studies in kidney journals.

    PubMed

    Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C

    2015-08-01

    Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.

  14. Meta-epidemiologic study showed frequent time trends in summary estimates from meta-analyses of diagnostic accuracy studies.

    PubMed

    Cohen, Jérémie F; Korevaar, Daniël A; Wang, Junfeng; Leeflang, Mariska M; Bossuyt, Patrick M

    2016-09-01

    To evaluate changes over time in summary estimates from meta-analyses of diagnostic accuracy studies. We included 48 meta-analyses from 35 MEDLINE-indexed systematic reviews published between September 2011 and January 2012 (743 diagnostic accuracy studies; 344,015 participants). Within each meta-analysis, we ranked studies by publication date. We applied random-effects cumulative meta-analysis to follow how summary estimates of sensitivity and specificity evolved over time. Time trends were assessed by fitting a weighted linear regression model of the summary accuracy estimate against rank of publication. The median of the 48 slopes was -0.02 (-0.08 to 0.03) for sensitivity and -0.01 (-0.03 to 0.03) for specificity. Twelve of 96 (12.5%) time trends in sensitivity or specificity were statistically significant. We found a significant time trend in at least one accuracy measure for 11 of the 48 (23%) meta-analyses. Time trends in summary estimates are relatively frequent in meta-analyses of diagnostic accuracy studies. Results from early meta-analyses of diagnostic accuracy studies should be considered with caution. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Sample size in studies on diagnostic accuracy in ophthalmology: a literature survey.

    PubMed

    Bochmann, Frank; Johnson, Zoe; Azuara-Blanco, Augusto

    2007-07-01

    To assess the sample sizes used in studies on diagnostic accuracy in ophthalmology. Design and sources: A survey literature published in 2005. The frequency of reporting calculations of sample sizes and the samples' sizes were extracted from the published literature. A manual search of five leading clinical journals in ophthalmology with the highest impact (Investigative Ophthalmology and Visual Science, Ophthalmology, Archives of Ophthalmology, American Journal of Ophthalmology and British Journal of Ophthalmology) was conducted by two independent investigators. A total of 1698 articles were identified, of which 40 studies were on diagnostic accuracy. One study reported that sample size was calculated before initiating the study. Another study reported consideration of sample size without calculation. The mean (SD) sample size of all diagnostic studies was 172.6 (218.9). The median prevalence of the target condition was 50.5%. Only a few studies consider sample size in their methods. Inadequate sample sizes in diagnostic accuracy studies may result in misleading estimates of test accuracy. An improvement over the current standards on the design and reporting of diagnostic studies is warranted.

  16. Death Anxiety in Persons with HIV/AIDS: A Systematic Review and Meta-Analysis

    ERIC Educational Resources Information Center

    Miller, Audrey K.; Lee, Brittany L.; Henderson, Craig E.

    2012-01-01

    One of the most commonly cited psychological sequelae of HIV/AIDS is anxiety regarding death due to the illness (i.e., death anxiety; DA). However, extant research is inconclusive on several empirical issues, such as DA's relation to HIV/AIDS diagnostic status, the impact of illness-related symptoms on DA, and factors that may protect against DA.…

  17. The Effect of Study Design Biases on the Diagnostic Accuracy of Magnetic Resonance Imaging to Detect Silicone Breast Implant Ruptures: A Meta-Analysis

    PubMed Central

    Song, Jae W.; Kim, Hyungjin Myra; Bellfi, Lillian T.; Chung, Kevin C.

    2010-01-01

    Background All silicone breast implant recipients are recommended by the US Food and Drug Administration to undergo serial screening to detect implant rupture with magnetic resonance imaging (MRI). We performed a systematic review of the literature to assess the quality of diagnostic accuracy studies utilizing MRI or ultrasound to detect silicone breast implant rupture and conducted a meta-analysis to examine the effect of study design biases on the estimation of MRI diagnostic accuracy measures. Method Studies investigating the diagnostic accuracy of MRI and ultrasound in evaluating ruptured silicone breast implants were identified using MEDLINE, EMBASE, ISI Web of Science, and Cochrane library databases. Two reviewers independently screened potential studies for inclusion and extracted data. Study design biases were assessed using the QUADAS tool and the STARDS checklist. Meta-analyses estimated the influence of biases on diagnostic odds ratios. Results Among 1175 identified articles, 21 met the inclusion criteria. Most studies using MRI (n= 10 of 16) and ultrasound (n=10 of 13) examined symptomatic subjects. Meta-analyses revealed that MRI studies evaluating symptomatic subjects had 14-fold higher diagnostic accuracy estimates compared to studies using an asymptomatic sample (RDOR 13.8; 95% CI 1.83–104.6) and 2-fold higher diagnostic accuracy estimates compared to studies using a screening sample (RDOR 1.89; 95% CI 0.05–75.7). Conclusion Many of the published studies utilizing MRI or ultrasound to detect silicone breast implant rupture are flawed with methodological biases. These methodological shortcomings may result in overestimated MRI diagnostic accuracy measures and should be interpreted with caution when applying the data to a screening population. PMID:21364405

  18. Diagnostic accuracy of ultrasonography, MRI and MR arthrography in the characterisation of rotator cuff disorders: a systematic review and meta-analysis

    PubMed Central

    Roy, Jean-Sébastien; Braën, Caroline; Leblond, Jean; Desmeules, François; Dionne, Clermont E; MacDermid, Joy C; Bureau, Nathalie J; Frémont, Pierre

    2015-01-01

    Background Different diagnostic imaging modalities, such as ultrasonography (US), MRI, MR arthrography (MRA) are commonly used for the characterisation of rotator cuff (RC) disorders. Since the most recent systematic reviews on medical imaging, multiple diagnostic studies have been published, most using more advanced technological characteristics. The first objective was to perform a meta-analysis on the diagnostic accuracy of medical imaging for characterisation of RC disorders. Since US is used at the point of care in environments such as sports medicine, a secondary analysis assessed accuracy by radiologists and non-radiologists. Methods A systematic search in three databases was conducted. Two raters performed data extraction and evaluation of risk of bias independently, and agreement was achieved by consensus. Hierarchical summary receiver-operating characteristic package was used to calculate pooled estimates of included diagnostic studies. Results Diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears was high with overall estimates of sensitivity and specificity over 0.90. As for partial RC tears and tendinopathy, overall estimates of specificity were also high (>0.90), while sensitivity was lower (0.67–0.83). Diagnostic accuracy of US was similar whether a trained radiologist, sonographer or orthopaedist performed it. Conclusions Our results show the diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears. Since full thickness tear constitutes a key consideration for surgical repair, this is an important characteristic when selecting an imaging modality for RC disorder. When considering accuracy, cost, and safety, US is the best option. PMID:25677796

  19. Reporting completeness and transparency of meta-analyses of depression screening tool accuracy: A comparison of meta-analyses published before and after the PRISMA statement.

    PubMed

    Rice, Danielle B; Kloda, Lorie A; Shrier, Ian; Thombs, Brett D

    2016-08-01

    Meta-analyses that are conducted rigorously and reported completely and transparently can provide accurate evidence to inform the best possible healthcare decisions. Guideline makers have raised concerns about the utility of existing evidence on the diagnostic accuracy of depression screening tools. The objective of our study was to evaluate the transparency and completeness of reporting in meta-analyses of the diagnostic accuracy of depression screening tools using the PRISMA tool adapted for diagnostic test accuracy meta-analyses. We searched MEDLINE and PsycINFO from January 1, 2005 through March 13, 2016 for recent meta-analyses in any language on the diagnostic accuracy of depression screening tools. Two reviewers independently assessed the transparency in reporting using the PRISMA tool with appropriate adaptations made for studies of diagnostic test accuracy. We identified 21 eligible meta-analyses. Twelve of 21 meta-analyses complied with at least 50% of adapted PRISMA items. Of 30 adapted PRISMA items, 11 were fulfilled by ≥80% of included meta-analyses, 3 by 50-79% of meta-analyses, 7 by 25-45% of meta-analyses, and 9 by <25%. On average, post-PRISMA meta-analyses complied with 17 of 30 items compared to 13 of 30 items pre-PRISMA. Deficiencies in the transparency of reporting in meta-analyses of the diagnostic test accuracy of depression screening tools of meta-analyses were identified. Authors, reviewers, and editors should adhere to the PRISMA statement to improve the reporting of meta-analyses of the diagnostic accuracy of depression screening tools. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. The diagnostic accuracy of 1.5T magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries.

    PubMed

    Wade, Ryckie G; Itte, Vinay; Rankine, James J; Ridgway, John P; Bourke, Grainne

    2018-03-01

    Identification of root avulsions is of critical importance in traumatic brachial plexus injuries because it alters the reconstruction and prognosis. Pre-operative magnetic resonance imaging is gaining popularity, but there is limited and conflicting data on its diagnostic accuracy for root avulsion. This cohort study describes consecutive patients requiring brachial plexus exploration following trauma between 2008 and 2016. The index test was magnetic resonance imaging at 1.5 Tesla and the reference test was operative exploration of the supraclavicular plexus. Complete data from 29 males was available. The diagnostic accuracy of magnetic resonance imaging for root avulsion(s) of C5-T1 was 79%. The diagnostic accuracy of a pseudomeningocoele as a surrogate marker of root avulsion(s) of C5-T1 was 68%. We conclude that pseudomeningocoles were not a reliable sign of root avulsion and magnetic resonance imaging has modest diagnostic accuracy for root avulsions in the context of adult traumatic brachial plexus injuries. III.

  1. Radiological interpretation of images displayed on tablet computers: a systematic review.

    PubMed

    Caffery, L J; Armfield, N R; Smith, A C

    2015-06-01

    To review the published evidence and to determine if radiological diagnostic accuracy is compromised when images are displayed on a tablet computer and thereby inform practice on using tablet computers for radiological interpretation by on-call radiologists. We searched the PubMed and EMBASE databases for studies on the diagnostic accuracy or diagnostic reliability of images interpreted on tablet computers. Studies were screened for inclusion based on pre-determined inclusion and exclusion criteria. Studies were assessed for quality and risk of bias using Quality Appraisal of Diagnostic Reliability Studies or the revised Quality Assessment of Diagnostic Accuracy Studies tool. Treatment of studies was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). 11 studies met the inclusion criteria. 10 of these studies tested the Apple iPad(®) (Apple, Cupertino, CA). The included studies reported high sensitivity (84-98%), specificity (74-100%) and accuracy rates (98-100%) for radiological diagnosis. There was no statistically significant difference in accuracy between a tablet computer and a digital imaging and communication in medicine-calibrated control display. There was a near complete consensus from authors on the non-inferiority of diagnostic accuracy of images displayed on a tablet computer. All of the included studies were judged to be at risk of bias. Our findings suggest that the diagnostic accuracy of radiological interpretation is not compromised by using a tablet computer. This result is only relevant to the Apple iPad and to the modalities of CT, MRI and plain radiography. The iPad may be appropriate for an on-call radiologist to use for radiological interpretation.

  2. Quality and reporting of diagnostic accuracy studies in TB, HIV and malaria: evaluation using QUADAS and STARD standards.

    PubMed

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-11-13

    Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004-2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.

  3. Quality and Reporting of Diagnostic Accuracy Studies in TB, HIV and Malaria: Evaluation Using QUADAS and STARD Standards

    PubMed Central

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-01-01

    Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases. PMID:19915664

  4. Diagnostic Accuracy of the Veteran Affairs' Traumatic Brain Injury Screen.

    PubMed

    Louise Bender Pape, Theresa; Smith, Bridget; Babcock-Parziale, Judith; Evans, Charlesnika T; Herrold, Amy A; Phipps Maieritsch, Kelly; High, Walter M

    2018-01-31

    To comprehensively estimate the diagnostic accuracy and reliability of the Department of Veterans Affairs (VA) Traumatic Brain Injury (TBI) Clinical Reminder Screen (TCRS). Cross-sectional, prospective, observational study using the Standards for Reporting of Diagnostic Accuracy criteria. Three VA Polytrauma Network Sites. Operation Iraqi Freedom, Operation Enduring Freedom veterans (N=433). TCRS, Comprehensive TBI Evaluation, Structured TBI Diagnostic Interview, Symptom Attribution and Classification Algorithm, and Clinician-Administered Posttraumatic Stress Disorder (PTSD) Scale. Forty-five percent of veterans screened positive on the TCRS for TBI. For detecting occurrence of historical TBI, the TCRS had a sensitivity of .56 to .74, a specificity of .63 to .93, a positive predictive value (PPV) of 25% to 45%, a negative predictive value (NPV) of 91% to 94%, and a diagnostic odds ratio (DOR) of 4 to 13. For accuracy of attributing active symptoms to the TBI, the TCRS had a sensitivity of .64 to .87, a specificity of .59 to .89, a PPV of 26% to 32%, an NPV of 92% to 95%, and a DOR of 6 to 9. The sensitivity was higher for veterans with PTSD (.80-.86) relative to veterans without PTSD (.57-.82). The specificity, however, was higher among veterans without PTSD (.75-.81) relative to veterans with PTSD (.36-.49). All indices of diagnostic accuracy changed when participants with questionably valid (QV) test profiles were eliminated from analyses. The utility of the TCRS to screen for mild TBI (mTBI) depends on the stringency of the diagnostic reference standard to which it is being compared, the presence/absence of PTSD, and QV test profiles. Further development, validation, and use of reproducible diagnostic algorithms for symptom attribution after possible mTBI would improve diagnostic accuracy. Published by Elsevier Inc.

  5. Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: a prospective analysis of immunoassay and liquid chromatography tandem mass spectometry (LC/MS/MS).

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E

    2010-01-01

    Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.

  6. Physical examination tests for screening and diagnosis of cervicogenic headache: A systematic review.

    PubMed

    Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E

    2016-02-01

    It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. A matter of accuracy. Nanobiochips in diagnostics and in research: ethical issues as value trade-offs.

    PubMed

    Le Roux, Ronan

    2015-04-01

    The paper deals with the introduction of nanotechnology in biochips. Based on interviews and theoretical reflections, it explores blind spots left by technology assessment and ethical investigations. These have focused on possible consequences of increased diffusability of a diagnostic device, neglecting both the context of research as well as increased accuracy, despite it being a more essential feature of nanobiochip projects. Also, rather than one of many parallel aspects (technical, legal and social) in innovation processes, ethics is considered here as a ubiquitous system of choices between sometimes antagonistic values. Thus, the paper investigates what is at stake when accuracy is balanced with other practical values in different contexts. Dramatic nanotechnological increase of accuracy in biochips can raise ethical issues, since it is at odds with other values such as diffusability and reliability. But those issues will not be as revolutionary as is often claimed: neither in diagnostics, because accuracy of measurements is not accuracy of diagnostics; nor in research, because a boost in measurement accuracy is not sufficient to overcome significance-chasing malpractices. The conclusion extends to methodological recommendations.

  8. Interpretation of bedside chest X-rays in the ICU: is the radiologist still needed?

    PubMed

    Martini, Katharina; Ganter, Christoph; Maggiorini, Marco; Winklehner, Anna; Leupi-Skibinski, Katarzyna E; Frauenfelder, Thomas; Nguyen-Kim, Thi Dan Linh

    2015-01-01

    To compare diagnostic accuracy of intensivists to radiologists in reading bedside chest X-rays. In a retrospective trial, 33 bedside chest X-rays were evaluated by five radiologists and five intensivists with different experience. Images were evaluated for devices and lung pathologies. Interobserver agreement and diagnostic accuracy were calculated. Computed tomography served as reference standard. Seniors had higher diagnostic accuracy than residents (mean-ExpB(Senior)=1.456; mean-ExpB(Resident)=1.635). Interobserver agreement for installations was more homogenously distributed between radiologists compared to intensivists (ExpB(Rad)=1.204-1.672; ExpB(Int)=1.005-2.368). Seniors had comparable diagnostic accuracy. No significant difference in diagnostic performance was seen between seniors of both disciplines, whereas the resident intensivists might still benefit from an interdisciplinary dialogue. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Diagnostic Accuracy of Natriuretic Peptides for Heart Failure in Patients with Pleural Effusion: A Systematic Review and Updated Meta-Analysis

    PubMed Central

    Cheng, Juan-Juan; Zhao, Shi-Di; Gao, Ming-Zhu; Huang, Hong-Yu; Gu, Bing; Ma, Ping; Chen, Yan; Wang, Jun-Hong; Yang, Cheng-Jian; Yan, Zi-He

    2015-01-01

    Background Previous studies have reported that natriuretic peptides in the blood and pleural fluid (PF) are effective diagnostic markers for heart failure (HF). These natriuretic peptides include N-terminal pro-brain natriuretic peptide (NT-proBNP), brain natriuretic peptide (BNP), and midregion pro-atrial natriuretic peptide (MR-proANP). This systematic review and meta-analysis evaluates the diagnostic accuracy of blood and PF natriuretic peptides for HF in patients with pleural effusion. Methods PubMed and EMBASE databases were searched to identify articles published in English that investigated the diagnostic accuracy of BNP, NT-proBNP, and MR-proANP for HF. The last search was performed on 9 October 2014. The quality of the eligible studies was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies tool. The diagnostic performance characteristics (sensitivity, specificity, and other measures of accuracy) were pooled and examined using a bivariate model. Results In total, 14 studies were included in the meta-analysis, including 12 studies reporting the diagnostic accuracy of PF NT-proBNP and 4 studies evaluating blood NT-proBNP. The summary estimates of PF NT-proBNP for HF had a diagnostic sensitivity of 0.94 (95% confidence interval [CI]: 0.90–0.96), specificity of 0.91 (95% CI: 0.86–0.95), positive likelihood ratio of 10.9 (95% CI: 6.4–18.6), negative likelihood ratio of 0.07 (95% CI: 0.04–0.12), and diagnostic odds ratio of 157 (95% CI: 57–430). The overall sensitivity of blood NT-proBNP for diagnosis of HF was 0.92 (95% CI: 0.86–0.95), with a specificity of 0.88 (95% CI: 0.77–0.94), positive likelihood ratio of 7.8 (95% CI: 3.7–16.3), negative likelihood ratio of 0.10 (95% CI: 0.06–0.16), and diagnostic odds ratio of 81 (95% CI: 27–241). The diagnostic accuracy of PF MR-proANP and blood and PF BNP was not analyzed due to the small number of related studies. Conclusions BNP, NT-proBNP, and MR-proANP, either in blood or PF, are effective tools for diagnosis of HF. Additional studies are needed to rigorously evaluate the diagnostic accuracy of PF and blood MR-proANP and BNP for the diagnosis of HF. PMID:26244664

  10. Combined use of epithelial membrane antigen and nuclear matrix protein 52 as sensitive biomarkers for detection of bladder cancer.

    PubMed

    Attallah, Abdelfattah M; El-Far, Mohamed; Abdallah, Sanaa O; El-Waseef, Ahmed M; Omran, Mohamed M; Abdelrazek, Mohamed A; Attallah, Ahmed A; Saadh, Mohamed J; Radwan, Mohamed; El-waffaey, Kholoud A; Abol-Enei, Hassan

    2015-11-11

    The advent of noninvasive urine-based markers as well as other novel modalities has yielded improved diagnostic accuracy. However, the new markers failed to reach higher sensitivity and specificity. We therefore evaluated the potential role of epithelial membrane antigen (EMA) and nuclear matrix protein 52 (NMP-52) singly and combined as noninvasive biomarkers for the detection of bladder cancer (BC). A total of 160 individuals including 66 patients with BC, 54 patients with benign urologic disorders and 40 healthy volunteers were investigated. Urinary EMA at 130 kDa and NMP at 52 kDa were identified, purified and quantified by Western blot, electroelution and enzyme-linked immunosorbent assay (ELISA). The diagnostic performance of each biomarker and their combination were compared using area under receiver operating characteristic curves (AUC). Mean urinary EMA, 2.42 µg/mL, and NMP-52, 17.85 µg/mL, were significantly elevated in patients with BC compared to controls, 1.18 and 3.44 µg/mL, respectively (p<0.0001). The combined use of these markers yielded values which were increased 4.4- and 13.7-fold in the benign and malignant disease groups, respectively, with respect to the normal group. The values of EMA and NMP-52 were significantly higher in patients with higher-grade tumors than those with lower-grade tumors (p<0.0001). Moreover, this combination could predict all BC stages and grades with 0.91 AUC, 94% sensitivity and 80% specificity. EMA and NMP-52 in combination could be promising noninvasive biomarkers for BC detection.

  11. Radiological interpretation of images displayed on tablet computers: a systematic review

    PubMed Central

    Armfield, N R; Smith, A C

    2015-01-01

    Objective: To review the published evidence and to determine if radiological diagnostic accuracy is compromised when images are displayed on a tablet computer and thereby inform practice on using tablet computers for radiological interpretation by on-call radiologists. Methods: We searched the PubMed and EMBASE databases for studies on the diagnostic accuracy or diagnostic reliability of images interpreted on tablet computers. Studies were screened for inclusion based on pre-determined inclusion and exclusion criteria. Studies were assessed for quality and risk of bias using Quality Appraisal of Diagnostic Reliability Studies or the revised Quality Assessment of Diagnostic Accuracy Studies tool. Treatment of studies was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). Results: 11 studies met the inclusion criteria. 10 of these studies tested the Apple iPad® (Apple, Cupertino, CA). The included studies reported high sensitivity (84–98%), specificity (74–100%) and accuracy rates (98–100%) for radiological diagnosis. There was no statistically significant difference in accuracy between a tablet computer and a digital imaging and communication in medicine-calibrated control display. There was a near complete consensus from authors on the non-inferiority of diagnostic accuracy of images displayed on a tablet computer. All of the included studies were judged to be at risk of bias. Conclusion: Our findings suggest that the diagnostic accuracy of radiological interpretation is not compromised by using a tablet computer. This result is only relevant to the Apple iPad and to the modalities of CT, MRI and plain radiography. Advances in knowledge: The iPad may be appropriate for an on-call radiologist to use for radiological interpretation. PMID:25882691

  12. Meta-analysis of stratus OCT glaucoma diagnostic accuracy.

    PubMed

    Chen, Hsin-Yi; Chang, Yue-Cune

    2014-09-01

    To evaluate the diagnostic accuracy of glaucoma in different stages, different types of glaucoma, and different ethnic groups using Stratus optical coherence tomography (OCT). We searched MEDLINE to identify available articles on diagnostic accuracy of glaucoma published between January 2004 and December 2011. A PubMed (National Center for Biotechnology Information) search using medical subject headings and keywords was executed using the following terms: "diagnostic accuracy" or "receiver operator characteristic" or "area under curve" or "AUC" and "Stratus OCT" and "glaucoma." The search was subsequently limited to publications in English. The area under a receiver operator characteristic (AUC) curve was used to measure the diagnostic performance. A random-effects model was used to estimate the pooled AUC value of the 17 parameters (average retinal nerve fiber layer thickness, temporal quadrant, superior quadrant, nasal quadrant, inferior quadrant, and 1 to 12 o'clock). Meta-regression analysis was used to check the significance of some important factors: (1) glaucoma severity (five stages), (2) glaucoma types (four types), and (3) ethnicity (four categories). The orders of accuracy among those parameters were as follows: average > inferior > superior > 7 o'clock > 6 o'clock > 11 o'clock > 12 o'clock > 1 o'clock > 5 o'clock > nasal > temporal > 2 o'clock > 10 o'clock > 8 o'clock > 9 o'clock > 4 o'clock > 3 o'clock. After adjusting for the effects of age, glaucoma severity, glaucoma types, and ethnicity, the average retinal nerve fiber layer thickness provided highest accuracy compared with the other parameters of OCT. The diagnostic accuracy in Asian populations was significantly lower than that in whites and the other two ethnic types. Stratus OCT demonstrated good diagnostic capability in differentiating glaucomatous from normal eyes. However, we should be more cautious in applying this instrument in Asian groups in glaucoma management.

  13. Accuracy of computer-aided diagnosis based on narrow-band imaging endocytoscopy for diagnosing colorectal lesions: comparison with experts.

    PubMed

    Misawa, Masashi; Kudo, Shin-Ei; Mori, Yuichi; Takeda, Kenichi; Maeda, Yasuharu; Kataoka, Shinichi; Nakamura, Hiroki; Kudo, Toyoki; Wakamura, Kunihiko; Hayashi, Takemasa; Katagiri, Atsushi; Baba, Toshiyuki; Ishida, Fumio; Inoue, Haruhiro; Nimura, Yukitaka; Oda, Msahiro; Mori, Kensaku

    2017-05-01

    Real-time characterization of colorectal lesions during colonoscopy is important for reducing medical costs, given that the need for a pathological diagnosis can be omitted if the accuracy of the diagnostic modality is sufficiently high. However, it is sometimes difficult for community-based gastroenterologists to achieve the required level of diagnostic accuracy. In this regard, we developed a computer-aided diagnosis (CAD) system based on endocytoscopy (EC) to evaluate cellular, glandular, and vessel structure atypia in vivo. The purpose of this study was to compare the diagnostic ability and efficacy of this CAD system with the performances of human expert and trainee endoscopists. We developed a CAD system based on EC with narrow-band imaging that allowed microvascular evaluation without dye (ECV-CAD). The CAD algorithm was programmed based on texture analysis and provided a two-class diagnosis of neoplastic or non-neoplastic, with probabilities. We validated the diagnostic ability of the ECV-CAD system using 173 randomly selected EC images (49 non-neoplasms, 124 neoplasms). The images were evaluated by the CAD and by four expert endoscopists and three trainees. The diagnostic accuracies for distinguishing between neoplasms and non-neoplasms were calculated. ECV-CAD had higher overall diagnostic accuracy than trainees (87.8 vs 63.4%; [Formula: see text]), but similar to experts (87.8 vs 84.2%; [Formula: see text]). With regard to high-confidence cases, the overall accuracy of ECV-CAD was also higher than trainees (93.5 vs 71.7%; [Formula: see text]) and comparable to experts (93.5 vs 90.8%; [Formula: see text]). ECV-CAD showed better diagnostic accuracy than trainee endoscopists and was comparable to that of experts. ECV-CAD could thus be a powerful decision-making tool for less-experienced endoscopists.

  14. Methodology and reporting of diagnostic accuracy studies of automated perimetry in glaucoma: evaluation using a standardised approach.

    PubMed

    Fidalgo, Bruno M R; Crabb, David P; Lawrenson, John G

    2015-05-01

    To evaluate methodological and reporting quality of diagnostic accuracy studies of perimetry in glaucoma and to determine whether there had been any improvement since the publication of the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines. A systematic review of English language articles published between 1993 and 2013 reporting the diagnostic accuracy of perimetry in glaucoma. Articles were appraised for methodological quality using the 14-item Quality assessment tool for diagnostic accuracy studies (QUADAS) and evaluated for quality of reporting by applying the STARD checklist. Fifty-eight articles were appraised. Overall methodological quality of these studies was moderate with a median number of QUADAS items rated as 'yes' equal to nine (out of a maximum of 14) (IQR 7-10). The studies were often poorly reported; median score of STARD items fully reported was 11 out of 25 (IQR 10-14). A comparison of the studies published in 10-year periods before and after the publication of the STARD checklist in 2003 found quality of reporting had not substantially improved. Methodological and reporting quality of diagnostic accuracy studies of perimetry is sub-optimal and appears not to have improved substantially following the development of the STARD reporting guidance. This observation is consistent with previous studies in ophthalmology and in other medical specialities. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  15. Diagnostic accuracy of fractional exhaled nitric oxide measurement in predicting cough-variant asthma and eosinophilic bronchitis in adults with chronic cough: A systematic review and meta-analysis.

    PubMed

    Song, Woo-Jung; Kim, Hyun Jung; Shim, Ji-Su; Won, Ha-Kyeong; Kang, Sung-Yoon; Sohn, Kyoung-Hee; Kim, Byung-Keun; Jo, Eun-Jung; Kim, Min-Hye; Kim, Sang-Heon; Park, Heung-Woo; Kim, Sun-Sin; Chang, Yoon-Seok; Morice, Alyn H; Lee, Byung-Jae; Cho, Sang-Heon

    2017-09-01

    Individual studies have suggested the utility of fractional exhaled nitric oxide (Feno) measurement in detecting cough-variant asthma (CVA) and eosinophilic bronchitis (EB) in patients with chronic cough. We sought to obtain summary estimates of diagnostic test accuracy of Feno measurement in predicting CVA, EB, or both in adults with chronic cough. Electronic databases were searched for studies published until January 2016, without language restriction. Cross-sectional studies that reported the diagnostic accuracy of Feno measurement for detecting CVA or EB were included. Risk of bias was assessed with Quality Assessment of Diagnostic Accuracy Studies 2. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy of Feno measurement. A total of 15 studies involving 2187 adults with chronic cough were identified. Feno measurement had a moderate diagnostic accuracy in predicting CVA in patients with chronic cough, showing the summary area under the curve to be 0.87 (95% CI, 0.83-0.89). Specificity was higher and more consistent than sensitivity (0.85 [95% CI, 0.81-0.88] and 0.72 [95% CI, 0.61-0.81], respectively). However, in the nonasthmatic population with chronic cough, the diagnostic accuracy to predict EB was found to be relatively lower (summary area under the curve, 0.81 [95% CI, 0.77-0.84]), and specificity was inconsistent. The present meta-analyses indicated the diagnostic potential of Feno measurement as a rule-in test for detecting CVA in adult patients with chronic cough. However, Feno measurement may not be useful to predict EB in nonasthmatic subjects with chronic cough. These findings warrant further studies to validate the roles of Feno measurement in clinical practice of patients with chronic cough. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  16. Radiologists’ Interpretive Skills in Screening vs. Diagnostic Mammography: Are They Related?

    PubMed Central

    Elmore, Joann G.; Cook, Andrea J.; Bogart, Andy; Carney, Patricia A.; Geller, Berta; Taplin, Stephen; Buist, Diana SM; Onega, Tracy; Lee, Christoph I.; Miglioretti, Diana L.

    2016-01-01

    Purpose To determine whether radiologists who perform well in screening also perform well in interpreting diagnostic mammography. Materials & Methods We evaluated the accuracy of 468 radiologists interpreting 2,234,947 screening and 196,164 diagnostic mammograms. Adjusting for site, radiologist, and patient characteristics, we identified radiologists with performance in the highest tertile and compared to those with lower performance. Results A moderate correlation was noted for radiologists’ accuracy when interpreting screening versus their accuracy on diagnostic exams: sensitivity (rspearman=0.51, 95% CI: 0.22, 0.80; P=0.0006), specificity (rspearman=0.40, 95% CI: 0.30, 0.49; P<0.0001). Conclusion Different educational approaches to screening and diagnostic imaging should be considered. PMID:27438069

  17. Does clinical pretest probability influence image quality and diagnostic accuracy in dual-source coronary CT angiography?

    PubMed

    Thomas, Christoph; Brodoefel, Harald; Tsiflikas, Ilias; Bruckner, Friederike; Reimann, Anja; Ketelsen, Dominik; Drosch, Tanja; Claussen, Claus D; Kopp, Andreas; Heuschmid, Martin; Burgstahler, Christof

    2010-02-01

    To prospectively evaluate the influence of the clinical pretest probability assessed by the Morise score onto image quality and diagnostic accuracy in coronary dual-source computed tomography angiography (DSCTA). In 61 patients, DSCTA and invasive coronary angiography were performed. Subjective image quality and accuracy for stenosis detection (>50%) of DSCTA with invasive coronary angiography as gold standard were evaluated. The influence of pretest probability onto image quality and accuracy was assessed by logistic regression and chi-square testing. Correlations of image quality and accuracy with the Morise score were determined using linear regression. Thirty-eight patients were categorized into the high, 21 into the intermediate, and 2 into the low probability group. Accuracies for the detection of significant stenoses were 0.94, 0.97, and 1.00, respectively. Logistic regressions and chi-square tests showed statistically significant correlations between Morise score and image quality (P < .0001 and P < .001) and accuracy (P = .0049 and P = .027). Linear regression revealed a cutoff Morise score for a good image quality of 16 and a cutoff for a barely diagnostic image quality beyond the upper Morise scale. Pretest probability is a weak predictor of image quality and diagnostic accuracy in coronary DSCTA. A sufficient image quality for diagnostic images can be reached with all pretest probabilities. Therefore, coronary DSCTA might be suitable also for patients with a high pretest probability. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  18. Proposed Diagnostic Criteria for Smartphone Addiction

    PubMed Central

    Lin, Yu-Hsuan; Chiang, Chih-Lin; Lin, Po-Hsien; Chang, Li-Ren; Ko, Chih-Hung; Lee, Yang-Han

    2016-01-01

    Background Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria. Methods We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist’s structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists’ clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy. Results Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1) six symptom criteria, (2) four functional impairment criteria and (3) exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%), while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use. Conclusion The diagnostic criteria of smartphone addiction demonstrated the core symptoms “impaired control” paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment. PMID:27846211

  19. Proposed Diagnostic Criteria for Smartphone Addiction.

    PubMed

    Lin, Yu-Hsuan; Chiang, Chih-Lin; Lin, Po-Hsien; Chang, Li-Ren; Ko, Chih-Hung; Lee, Yang-Han; Lin, Sheng-Hsuan

    2016-01-01

    Global smartphone penetration has led to unprecedented addictive behaviors. The aims of this study are to develop diagnostic criteria of smartphone addiction and to examine the discriminative ability and the validity of the diagnostic criteria. We developed twelve candidate criteria for characteristic symptoms of smartphone addiction and four criteria for functional impairment caused by excessive smartphone use. The participants consisted of 281 college students. Each participant was systematically assessed for smartphone-using behaviors by psychiatrist's structured diagnostic interview. The sensitivity, specificity, and diagnostic accuracy of the candidate symptom criteria were analyzed with reference to the psychiatrists' clinical global impression. The optimal model selection with its cutoff point of the diagnostic criteria differentiating the smartphone addicted subjects from non-addicted subjects was then determined by the best diagnostic accuracy. Six symptom criteria model with optimal cutoff point were determined based on the maximal diagnostic accuracy. The proposed smartphone addiction diagnostic criteria consisted of (1) six symptom criteria, (2) four functional impairment criteria and (3) exclusion criteria. Setting three symptom criteria as the cutoff point resulted in the highest diagnostic accuracy (84.3%), while the sensitivity and specificity were 79.4% and 87.5%, respectively. We suggested determining the functional impairment by two or more of the four domains considering the high accessibility and penetration of smartphone use. The diagnostic criteria of smartphone addiction demonstrated the core symptoms "impaired control" paralleled with substance related and addictive disorders. The functional impairment involved multiple domains provide a strict standard for clinical assessment.

  20. Fault detection and diagnosis of diesel engine valve trains

    NASA Astrophysics Data System (ADS)

    Flett, Justin; Bone, Gary M.

    2016-05-01

    This paper presents the development of a fault detection and diagnosis (FDD) system for use with a diesel internal combustion engine (ICE) valve train. A novel feature is generated for each of the valve closing and combustion impacts. Deformed valve spring faults and abnormal valve clearance faults were seeded on a diesel engine instrumented with one accelerometer. Five classification methods were implemented experimentally and compared. The FDD system using the Naïve-Bayes classification method produced the best overall performance, with a lowest detection accuracy (DA) of 99.95% and a lowest classification accuracy (CA) of 99.95% for the spring faults occurring on individual valves. The lowest DA and CA values for multiple faults occurring simultaneously were 99.95% and 92.45%, respectively. The DA and CA results demonstrate the accuracy of our FDD system for diesel ICE valve train fault scenarios not previously addressed in the literature.

  1. Interobserver Variability and Accuracy of High-Definition Endoscopic Diagnosis for Gastric Intestinal Metaplasia among Experienced and Inexperienced Endoscopists

    PubMed Central

    Hyun, Yil Sik; Bae, Joong Ho; Park, Hye Sun; Eun, Chang Soo

    2013-01-01

    Accurate diagnosis of gastric intestinal metaplasia is important; however, conventional endoscopy is known to be an unreliable modality for diagnosing gastric intestinal metaplasia (IM). The aims of the study were to evaluate the interobserver variation in diagnosing IM by high-definition (HD) endoscopy and the diagnostic accuracy of this modality for IM among experienced and inexperienced endoscopists. Selected 50 cases, taken with HD endoscopy, were sent for a diagnostic inquiry of gastric IM through visual inspection to five experienced and five inexperienced endoscopists. The interobserver agreement between endoscopists was evaluated to verify the diagnostic reliability of HD endoscopy in diagnosing IM, and the diagnostic accuracy, sensitivity, and specificity were evaluated for validity of HD endoscopy in diagnosing IM. Interobserver agreement among the experienced endoscopists was "poor" (κ = 0.38) and it was also "poor" (κ = 0.33) among the inexperienced endoscopists. The diagnostic accuracy of the experienced endoscopists was superior to that of the inexperienced endoscopists (P = 0.003). Since diagnosis through visual inspection is unreliable in the diagnosis of IM, all suspicious areas for gastric IM should be considered to be biopsied. Furthermore, endoscopic experience and education are needed to raise the diagnostic accuracy of gastric IM. PMID:23678267

  2. Comparison between fine needle aspiration cytology (FNAC) and core needle biopsy (CNB) in the diagnosis of breast lesions.

    PubMed

    Moschetta, M; Telegrafo, M; Carluccio, D A; Jablonska, J P; Rella, L; Serio, Gabriella; Carrozzo, M; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To compare the diagnostic accuracy of fine-needle aspiration cytology (FNAC) and core needle biopsy (CNB) in patients with USdetected breast lesions. Between September 2011 and May 2013, 3469 consecutive breast US examinations were performed. 400 breast nodules were detected in 398 patients. 210 FNACs and 190 CNBs were performed. 183 out of 400 (46%) lesions were surgically removed within 30 days form diagnosis; in the remaining cases, a six month follow up US examination was performed. Sensitivity, specificity, diagnostic accuracy, positive predictive (PPV) and negative predictive (NPV) values were calculated for FNAC and CNB. 174 out of 400 (43%) malignant lesions were found while the remaining 226 resulted to be benign lesions. 166 out of 210 (79%) FNACs and 154 out of 190 (81%) CNBs provided diagnostic specimens. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 94%, 95%, 91% and 98% were found for FNAC, and values of 92%, 82%, 89%, 92% and 82% were obtained for CNB. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 97%, 96%, 96%, 97% and 96% were found for FNAC, and values of 97%, 96%, 96%, 97% and 96% were obtained for CNB. FNAC and CNB provide similar values of diagnostic accuracy.

  3. Interobserver variability and accuracy of high-definition endoscopic diagnosis for gastric intestinal metaplasia among experienced and inexperienced endoscopists.

    PubMed

    Hyun, Yil Sik; Han, Dong Soo; Bae, Joong Ho; Park, Hye Sun; Eun, Chang Soo

    2013-05-01

    Accurate diagnosis of gastric intestinal metaplasia is important; however, conventional endoscopy is known to be an unreliable modality for diagnosing gastric intestinal metaplasia (IM). The aims of the study were to evaluate the interobserver variation in diagnosing IM by high-definition (HD) endoscopy and the diagnostic accuracy of this modality for IM among experienced and inexperienced endoscopists. Selected 50 cases, taken with HD endoscopy, were sent for a diagnostic inquiry of gastric IM through visual inspection to five experienced and five inexperienced endoscopists. The interobserver agreement between endoscopists was evaluated to verify the diagnostic reliability of HD endoscopy in diagnosing IM, and the diagnostic accuracy, sensitivity, and specificity were evaluated for validity of HD endoscopy in diagnosing IM. Interobserver agreement among the experienced endoscopists was "poor" (κ = 0.38) and it was also "poor" (κ = 0.33) among the inexperienced endoscopists. The diagnostic accuracy of the experienced endoscopists was superior to that of the inexperienced endoscopists (P = 0.003). Since diagnosis through visual inspection is unreliable in the diagnosis of IM, all suspicious areas for gastric IM should be considered to be biopsied. Furthermore, endoscopic experience and education are needed to raise the diagnostic accuracy of gastric IM.

  4. The diagnostic accuracy of multiparametric MRI to determine pediatric brain tumor grades and types.

    PubMed

    Koob, Mériam; Girard, Nadine; Ghattas, Badih; Fellah, Slim; Confort-Gouny, Sylviane; Figarella-Branger, Dominique; Scavarda, Didier

    2016-04-01

    Childhood brain tumors show great histological variability. The goal of this retrospective study was to assess the diagnostic accuracy of multimodal MR imaging (diffusion, perfusion, MR spectroscopy) in the distinction of pediatric brain tumor grades and types. Seventy-six patients (range 1 month to 18 years) with brain tumors underwent multimodal MR imaging. Tumors were categorized by grade (I-IV) and by histological type (A-H). Multivariate statistical analysis was performed to evaluate the diagnostic accuracy of single and combined MR modalities, and of single imaging parameters to distinguish the different groups. The highest diagnostic accuracy for tumor grading was obtained with diffusion-perfusion (73.24%) and for tumor typing with diffusion-perfusion-MR spectroscopy (55.76%). The best diagnostic accuracy was obtained for tumor grading in I and IV and for tumor typing in embryonal tumor and pilocytic astrocytoma. Poor accuracy was seen in other grades and types. ADC and rADC were the best parameters for tumor grading and typing followed by choline level with an intermediate echo time, CBV for grading and Tmax for typing. Multiparametric MR imaging can be accurate in determining tumor grades (primarily grades I and IV) and types (mainly pilocytic astrocytomas and embryonal tumors) in children.

  5. Attribute-Level and Pattern-Level Classification Consistency and Accuracy Indices for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Wang, Wenyi; Song, Lihong; Chen, Ping; Meng, Yaru; Ding, Shuliang

    2015-01-01

    Classification consistency and accuracy are viewed as important indicators for evaluating the reliability and validity of classification results in cognitive diagnostic assessment (CDA). Pattern-level classification consistency and accuracy indices were introduced by Cui, Gierl, and Chang. However, the indices at the attribute level have not yet…

  6. A PC-based generator of surface ECG potentials for computer electrocardiograph testing.

    PubMed

    Franchi, D; Palagi, G; Bedini, R

    1994-02-01

    The system is composed of an electronic circuit, connected to a PC, whose outputs, starting from ECGs digitally collected by commercial interpretative electrocardiographs, simulate virtual patients' limb and chest electrode potentials. Appropriate software manages the D/A conversion and lines up the original short-term signal in a ring buffer to generate continuous ECG traces. The device also permits the addition of artifacts and/or baseline wanders/shifts on each lead separately. The system has been accurately tested and statistical indexes have been computed to quantify the reproduction accuracy analyzing, in the generated signal, both the errors induced on the fiducial point measurements and the capability to retain the diagnostic significance. The device integrated with an annotated ECG data base constitutes a reliable and powerful system to be used in the quality assurance testing of computer electrocardiographs.

  7. Sublingual Nitroglycerin Administration in Coronary Computed Tomography Angiography: a Systematic Review.

    PubMed

    Takx, Richard A P; Suchá, Dominika; Park, Jakob; Leiner, Tim; Hoffmann, Udo

    2015-12-01

    To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography. A systematic search was performed in PubMed, EMBASE and Web of Science. The studies were evaluated for the effect of sublingual nitroglycerin on coronary artery diameter, evaluable segments, objective and subjective image quality, systemic physiological effects and diagnostic accuracy. Due to the heterogeneous reporting of outcome measures, a narrative synthesis was applied. Of the 217 studies identified, nine met the inclusion criteria: seven reported on the effect of nitroglycerin on coronary artery diameter, six on evaluable segments, four on image quality, five on systemic physiological effects and two on diagnostic accuracy. Sublingual nitroglycerin administration resulted in an improved evaluation of more coronary segments, in particular, in smaller coronary branches, better image quality and improved diagnostic accuracy. Side effects were mild and were alleviated without medical intervention. Sublingual nitroglycerin improves the coronary diameter, the number of assessable segments, image quality and diagnostic accuracy of coronary CT angiography without major side effects or systemic physiological changes. • Sublingual nitroglycerin administration results in significant coronary artery dilatation. • Nitroglycerin increases the number of evaluable coronary branches. • Image quality is improved the most in smaller coronary branches. • Nitroglycerin increases the diagnostic accuracy of coronary CT angiography. • Most side effects are mild and do not require medical intervention.

  8. The role of semantically related distractors during encoding and retrieval of words in long-term memory.

    PubMed

    Meade, Melissa E; Fernandes, Myra A

    2016-07-01

    We examined the influence of divided attention (DA) on recognition of words when the concurrent task was semantically related or unrelated to the to-be-recognised target words. Participants were asked to either study or retrieve a target list of semantically related words while simultaneously making semantic decisions (i.e., size judgements) to another set of related or unrelated words heard concurrently. We manipulated semantic relatedness of distractor to target words, and whether DA occurred during the encoding or retrieval phase of memory. Recognition accuracy was significantly diminished relative to full attention, following DA conditions at encoding, regardless of relatedness of distractors to study words. However, response times (RTs) were slower with related compared to unrelated distractors. Similarly, under DA at retrieval, recognition RTs were slower when distractors were semantically related than unrelated to target words. Unlike the effect from DA at encoding, recognition accuracy was worse under DA at retrieval when the distractors were related compared to unrelated to the target words. Results suggest that availability of general attentional resources is critical for successful encoding, whereas successful retrieval is particularly reliant on access to a semantic code, making it sensitive to related distractors under DA conditions.

  9. Evaluation of diagnostic accuracy in detecting ordered symptom statuses without a gold standard

    PubMed Central

    Wang, Zheyu; Zhou, Xiao-Hua; Wang, Miqu

    2011-01-01

    Our research is motivated by 2 methodological problems in assessing diagnostic accuracy of traditional Chinese medicine (TCM) doctors in detecting a particular symptom whose true status has an ordinal scale and is unknown—imperfect gold standard bias and ordinal scale symptom status. In this paper, we proposed a nonparametric maximum likelihood method for estimating and comparing the accuracy of different doctors in detecting a particular symptom without a gold standard when the true symptom status had an ordered multiple class. In addition, we extended the concept of the area under the receiver operating characteristic curve to a hyper-dimensional overall accuracy for diagnostic accuracy and alternative graphs for displaying a visual result. The simulation studies showed that the proposed method had good performance in terms of bias and mean squared error. Finally, we applied our method to our motivating example on assessing the diagnostic abilities of 5 TCM doctors in detecting symptoms related to Chills disease. PMID:21209155

  10. Design of Malaria Diagnostic Criteria for the Sysmex XE-2100 Hematology Analyzer

    PubMed Central

    Campuzano-Zuluaga, Germán; Álvarez-Sánchez, Gonzalo; Escobar-Gallo, Gloria Elcy; Valencia-Zuluaga, Luz Marina; Ríos-Orrego, Alexandra Marcela; Pabón-Vidal, Adriana; Miranda-Arboleda, Andrés Felipe; Blair-Trujillo, Silvia; Campuzano-Maya, Germán

    2010-01-01

    Thick film, the standard diagnostic procedure for malaria, is not always ordered promptly. A failsafe diagnostic strategy using an XE-2100 analyzer is proposed, and for this strategy, malaria diagnostic models for the XE-2100 were developed and tested for accuracy. Two hundred eighty-one samples were distributed into Plasmodium vivax, P. falciparum, and acute febrile syndrome groups for model construction. Model validation was performed using 60% of malaria cases and a composite control group of samples from AFS and healthy participants from endemic and non-endemic regions. For P. vivax, two observer-dependent models (accuracy = 95.3–96.9%), one non–observer-dependent model using built-in variables (accuracy = 94.7%), and one non–observer-dependent model using new and built-in variables (accuracy = 96.8%) were developed. For P. falciparum, two non–observer-dependent models (accuracies = 85% and 89%) were developed. These models could be used by health personnel or be integrated as a malaria alarm for the XE-2100 to prompt early malaria microscopic diagnosis. PMID:20207864

  11. A plastic corticostriatal circuit model of adaptation in perceptual decision making

    PubMed Central

    Hsiao, Pao-Yueh; Lo, Chung-Chuan

    2013-01-01

    The ability to optimize decisions and adapt them to changing environments is a crucial brain function that increase survivability. Although much has been learned about the neuronal activity in various brain regions that are associated with decision making, and about how the nervous systems may learn to achieve optimization, the underlying neuronal mechanisms of how the nervous systems optimize decision strategies with preference given to speed or accuracy, and how the systems adapt to changes in the environment, remain unclear. Based on extensive empirical observations, we addressed the question by extending a previously described cortico-basal ganglia circuit model of perceptual decisions with the inclusion of a dynamic dopamine (DA) system that modulates spike-timing dependent plasticity (STDP). We found that, once an optimal model setting that maximized the reward rate was selected, the same setting automatically optimized decisions across different task environments through dynamic balancing between the facilitating and depressing components of the DA dynamics. Interestingly, other model parameters were also optimal if we considered the reward rate that was weighted by the subject's preferences for speed or accuracy. Specifically, the circuit model favored speed if we increased the phasic DA response to the reward prediction error, whereas the model favored accuracy if we reduced the tonic DA activity or the phasic DA responses to the estimated reward probability. The proposed model provides insight into the roles of different components of DA responses in decision adaptation and optimization in a changing environment. PMID:24339814

  12. Vi-da: vitiligo diagnostic assistance mobile application

    NASA Astrophysics Data System (ADS)

    Nugraha, G. A.; Nurhudatiana, A.; Bahana, R.

    2018-03-01

    Vitiligo is a skin disorder in which white patches of depigmentation appear on different parts of the body. Usually, patients come to hospitals or clinics to have their vitiligo conditions assessed. This can be very tiring to the patients, as vitiligo treatments usually take a relatively long period of time, which can range from months to years. To address this challenge, we present in this paper a prototype of an Android-based mobile application called Vi-DA, which stands for Vitiligo Diagnostic Assistance. Vi-DA consists of three subsystems, which are user sign-up subsystem, camera and image analysis subsystem, and progress report subsystem. The mobile application was developed in Java programming language and uses MySQL as the database system. Vi-DA adopts a vitiligo segmentation algorithm to segment input image into normal skin area, vitiligo skin area, and non-skin area. Results showed that Vi-DA gave comparable results to the previous system implemented in Matlab. User acceptance testing results also showed that all respondents agreed on the usefulness of the system and agreed to use Vi-DA again in the future. Vi-DA benefits both dermatologists and patients as not only a computer-aided diagnosis (CAD) tool but also as a smart application that can be used for self-assessment at home.

  13. The diagnostic test accuracy of magnetic resonance imaging, magnetic resonance arthrography and computer tomography in the detection of chondral lesions of the hip.

    PubMed

    Smith, Toby O; Simpson, Michael; Ejindu, Vivian; Hing, Caroline B

    2013-04-01

    The purpose of this study was to assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and multidetector arrays in CT arthrography (MDCT) for assessing chondral lesions in the hip joint. A review of the published and unpublished literature databases was performed to identify all studies reporting the diagnostic test accuracy (sensitivity/specificity) of MRI, MRA or MDCT for the assessment of adults with chondral (cartilage) lesions of the hip with surgical comparison (arthroscopic or open) as the reference test. All included studies were reviewed using the quality assessment of diagnostic accuracy studies appraisal tool. Pooled sensitivity, specificity, likelihood ratios and diagnostic odds ratios were calculated with 95 % confidence intervals using a random-effects meta-analysis for MRI, MRA and MDCT imaging. Eighteen studies satisfied the eligibility criteria. These included 648 hips from 637 patients. MRI indicated a pooled sensitivity of 0.59 (95 % CI: 0.49-0.70) and specificity of 0.94 (95 % CI: 0.90-0.97), and MRA sensitivity and specificity values were 0.62 (95 % CI: 0.57-0.66) and 0.86 (95 % CI: 0.83-0.89), respectively. The diagnostic test accuracy for the detection of hip joint cartilage lesions is currently superior for MRI compared with MRA. There were insufficient data to perform meta-analysis for MDCT or CTA protocols. Based on the current limited diagnostic test accuracy of the use of magnetic resonance or CT, arthroscopy remains the most accurate method of assessing chondral lesions in the hip joint.

  14. Diagnostic Accuracy Assessment of Sensititre and Agar Disk Diffusion for Determining Antimicrobial Resistance Profiles of Bovine Clinical Mastitis Pathogens▿

    PubMed Central

    Saini, V.; Riekerink, R. G. M. Olde; McClure, J. T.; Barkema, H. W.

    2011-01-01

    Determining the accuracy and precision of a measuring instrument is pertinent in antimicrobial susceptibility testing. This study was conducted to predict the diagnostic accuracy of the Sensititre MIC mastitis panel (Sensititre) and agar disk diffusion (ADD) method with reference to the manual broth microdilution test method for antimicrobial resistance profiling of Escherichia coli (n = 156), Staphylococcus aureus (n = 154), streptococcal (n = 116), and enterococcal (n = 31) bovine clinical mastitis isolates. The activities of ampicillin, ceftiofur, cephalothin, erythromycin, oxacillin, penicillin, the penicillin-novobiocin combination, pirlimycin, and tetracycline were tested against the isolates. Diagnostic accuracy was determined by estimating the area under the receiver operating characteristic curve; intertest essential and categorical agreements were determined as well. Sensititre and the ADD method demonstrated moderate to highly accurate (71 to 99%) and moderate to perfect (71 to 100%) predictive accuracies for 74 and 76% of the isolate-antimicrobial MIC combinations, respectively. However, the diagnostic accuracy was low for S. aureus-ceftiofur/oxacillin combinations and other streptococcus-ampicillin combinations by either testing method. Essential agreement between Sensititre automatic MIC readings and MIC readings obtained by the broth microdilution test method was 87%. Essential agreement between Sensititre automatic and manual MIC reading methods was 97%. Furthermore, the ADD test method and Sensititre MIC method exhibited 92 and 91% categorical agreement (sensitive, intermediate, resistant) of results, respectively, compared with the reference method. However, both methods demonstrated lower agreement for E. coli-ampicillin/cephalothin combinations than for Gram-positive isolates. In conclusion, the Sensititre and ADD methods had moderate to high diagnostic accuracy and very good essential and categorical agreement for most udder pathogen-antimicrobial combinations and can be readily employed in veterinary diagnostic laboratories. PMID:21270215

  15. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high-grade glioma, a systematic review and meta-analysis.

    PubMed

    van Dijken, Bart R J; van Laar, Peter Jan; Holtman, Gea A; van der Hoorn, Anouk

    2017-10-01

    Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. • Treatment response assessment in high-grade gliomas with anatomical MRI is unreliable • Novel advanced MRI techniques have been studied, but diagnostic accuracy is unknown • Meta-analysis demonstrates that advanced MRI showed higher diagnostic accuracy than anatomical MRI • Highest diagnostic accuracy for spectroscopy and perfusion MRI • Supports the incorporation of advanced MRI in high-grade glioma treatment response assessment.

  16. Integrative literature review of the reported uses of serological tests in leprosy management.

    PubMed

    Fabri, Angélica da Conceição Oliveira Coelho; Carvalho, Ana Paula Mendes; Vieira, Nayara Figueiredo; Bueno, Isabela de Caux; Rodrigues, Rayssa Nogueira; Monteiro, Thayenne Barrozo Mota; Correa-Oliveira, Rodrigo; Duthie, Malcolm S; Lana, Francisco Carlos Félix

    2016-04-01

    An integrative literature review was conducted to synthesize available publications regarding the potential use of serological tests in leprosy programs. We searched the databases Literatura Latino-Americana e do Caribe em Ciências da Saúde, Índice Bibliográfico Espanhol em Ciências da Saúde, Acervo da Biblioteca da Organização Pan-Americana da Saúde, Medical Literature Analysis and Retrieval System Online, Hanseníase, National Library of Medicine, Scopus, Ovid, Cinahl, and Web of Science for articles investigating the use of serological tests for antibodies against phenolic glycolipid-I (PGL-I), ML0405, ML2331, leprosy IDRI diagnostic-1 (LID-1), and natural disaccharide octyl-leprosy IDRI diagnostic-1 (NDO-LID). From an initial pool of 3.514 articles, 40 full-length articles fulfilled our inclusion criteria. Based on these papers, we concluded that these antibodies can be used to assist in diagnosing leprosy, detecting neuritis, monitoring therapeutic efficacy, and monitoring household contacts or at-risk populations in leprosy-endemic areas. Thus, available data suggest that serological tests could contribute substantially to leprosy management.

  17. Indexing of Diagnostic Accuracy Studies in MEDLINE and EMBASE

    PubMed Central

    Wilczynski, Nancy L.; Haynes, R. Brian

    2007-01-01

    Background: STAndards for Reporting of Diagnostic Accuracy (STARD) were published in 2003 and endorsed by some journals but not others. Objective: To determine whether the quality of indexing of diagnostic accuracy studies in MEDLINE and EMBASE has improved since the STARD statement was published. Design: Evaluate the change in the mean number of “accurate index terms” assigned to diagnostic accuracy studies, comparing STARD (endorsing) and non-STARD (non-endorsing) journals, for 2 years before and after STARD publication. Results: In MEDLINE, no differences in indexing quality were found for STARD and non-STARD journals before or after the STARD statement was published in 2003. In EMBASE, indexing in STARD journals improved compared with non-STARD journals (p = 0.02). However, articles in STARD journals had half the number of accurate indexing terms as articles in non-STARD journals, both before and after STARD statement publication (p < 0.001). PMID:18693947

  18. ROC curve analyses of eyewitness identification decisions: An analysis of the recent debate.

    PubMed

    Rotello, Caren M; Chen, Tina

    2016-01-01

    How should the accuracy of eyewitness identification decisions be measured, so that best practices for identification can be determined? This fundamental question is under intense debate. One side advocates for continued use of a traditional measure of identification accuracy, known as the diagnosticity ratio , whereas the other side argues that receiver operating characteristic curves (ROCs) should be used instead because diagnosticity is confounded with response bias. Diagnosticity proponents have offered several criticisms of ROCs, which we show are either false or irrelevant to the assessment of eyewitness accuracy. We also show that, like diagnosticity, Bayesian measures of identification accuracy confound response bias with witnesses' ability to discriminate guilty from innocent suspects. ROCs are an essential tool for distinguishing memory-based processes from decisional aspects of a response; simulations of different possible identification tasks and response strategies show that they offer important constraints on theory development.

  19. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    PubMed

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  20. Using meta-analysis to inform the design of subsequent studies of diagnostic test accuracy.

    PubMed

    Hinchliffe, Sally R; Crowther, Michael J; Phillips, Robert S; Sutton, Alex J

    2013-06-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial evidence to underpin reliable clinical decision-making. Very few investigators consider any sample size calculations when designing a new diagnostic accuracy study. However, it is important to consider the number of subjects in a new study in order to achieve a precise measure of accuracy. Sutton et al. have suggested previously that when designing a new therapeutic trial, it could be more beneficial to consider the power of the updated meta-analysis including the new trial rather than of the new trial itself. The methodology involves simulating new studies for a range of sample sizes and estimating the power of the updated meta-analysis with each new study added. Plotting the power values against the range of sample sizes allows the clinician to make an informed decision about the sample size of a new trial. This paper extends this approach from the trial setting and applies it to diagnostic accuracy studies. Several meta-analytic models are considered including bivariate random effects meta-analysis that models the correlation between sensitivity and specificity. Copyright © 2012 John Wiley & Sons, Ltd. Copyright © 2012 John Wiley & Sons, Ltd.

  1. A structured proteomic approach identifies 14-3-3Sigma as a novel and reliable protein biomarker in panel based differential diagnostics of liver tumors.

    PubMed

    Reis, Henning; Pütter, Carolin; Megger, Dominik A; Bracht, Thilo; Weber, Frank; Hoffmann, Andreas-C; Bertram, Stefanie; Wohlschläger, Jeremias; Hagemann, Sascha; Eisenacher, Martin; Scherag, André; Schlaak, Jörg F; Canbay, Ali; Meyer, Helmut E; Sitek, Barbara; Baba, Hideo A

    2015-06-01

    Hepatocellular carcinoma (HCC) is a major lethal cancer worldwide. Despite sophisticated diagnostic algorithms, the differential diagnosis of small liver nodules still is difficult. While imaging techniques have advanced, adjuvant protein-biomarkers as glypican3 (GPC3), glutamine-synthetase (GS) and heat-shock protein 70 (HSP70) have enhanced diagnostic accuracy. The aim was to further detect useful protein-biomarkers of HCC with a structured systematic approach using differential proteome techniques, bring the results to practical application and compare the diagnostic accuracy of the candidates with the established biomarkers. After label-free and gel-based proteomics (n=18 HCC/corresponding non-tumorous liver tissue (NTLT)) biomarker candidates were tested for diagnostic accuracy in immunohistochemical analyses (n=14 HCC/NTLT). Suitable candidates were further tested for consistency in comparison to known protein-biomarkers in HCC (n=78), hepatocellular adenoma (n=25; HCA), focal nodular hyperplasia (n=28; FNH) and cirrhosis (n=28). Of all protein-biomarkers, 14-3-3Sigma (14-3-3S) exhibited the most pronounced up-regulation (58.8×) in proteomics and superior diagnostic accuracy (73.0%) in the differentiation of HCC from non-tumorous hepatocytes also compared to established biomarkers as GPC3 (64.7%) and GS (45.4%). 14-3-3S was part of the best diagnostic three-biomarker panel (GPC3, HSP70, 14-3-3S) for the differentiation of HCC and HCA which is of most important significance. Exclusion of GS and inclusion of 14-3-3S in the panel (>1 marker positive) resulted in a profound increase in specificity (+44.0%) and accuracy (+11.0%) while sensitivity remained stable (96.0%). 14-3-3S is an interesting protein biomarker with the potential to further improve the accuracy of differential diagnostic process of hepatocellular tumors. This article is part of a Special Issue entitled: Medical Proteomics. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Instantaneous wave-free ratio as an alternative to fractional flow reserve in assessment of moderate coronary stenoses: A meta-analysis of diagnostic accuracy studies.

    PubMed

    Maini, Rohit; Moscona, John; Katigbak, Paul; Fernandez, Camilo; Sidhu, Gursukhmandeep; Saleh, Qusai; Irimpen, Anand; Samson, Rohan; LeJemtel, Thierry

    2017-12-27

    Fractional flow reserve (FFR) remains underutilized due to practical concerns related to the need for hyperemic agents. These concerns have prompted the study of instantaneous wave-free ratio (iFR), a vasodilator-free index of coronary stenosis. Non-inferior cardiovascular outcomes have been demonstrated in two recent randomized clinic trials. We performed this meta-analysis to provide a necessary update of the diagnostic accuracy of iFR referenced to FFR based on the addition of eight more recent studies and 3727 more lesions. We searched the PubMed, EMBASE, Central, ProQuest, and Web of Science databases for full text articles published through May 31, 2017 to identify studies addressing the diagnostic accuracy of iFR referenced to FFR≤0.80. The following keywords were used: "instantaneous wave-free ratio" OR "iFR" AND "fractional flow reserve" OR "FFR." In total, 16 studies comprising 5756 lesions were identified. Pooled diagnostic accuracy estimates of iFR versus FFR≤0.80 were: sensitivity, 0.78 (95% CI, 0.76-0.79); specificity, 0.83 (0.81-0.84); positive likelihood ratio, 4.54 (3.85-5.35); negative likelihood ratio, 0.28 (0.24-0.32); diagnostic odds ratio, 17.38 (14.16-21.34); area under the summary receiver-operating characteristic curve, 0.87; and an overall diagnostic accuracy of 0.81 (0.78-0.84). In conclusion, iFR showed excellent agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. When considering along with its clinical outcome data and ease of application, the diagnostic accuracy of iFR supports its use as a suitable alternative to FFR for physiology-guided revascularization of moderate coronary stenoses. We performed a meta-analysis of the diagnostic accuracy of iFR referenced to FFR. iFR showed excellent agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. This supports its use as a suitable alternative to FFR for physiology-guided revascularization of moderate coronary stenoses. Copyright © 2017. Published by Elsevier Inc.

  3. Using Language Sample Analysis in Clinical Practice: Measures of Grammatical Accuracy for Identifying Language Impairment in Preschool and School-Aged Children.

    PubMed

    Eisenberg, Sarita; Guo, Ling-Yu

    2016-05-01

    This article reviews the existing literature on the diagnostic accuracy of two grammatical accuracy measures for differentiating children with and without language impairment (LI) at preschool and early school age based on language samples. The first measure, the finite verb morphology composite (FVMC), is a narrow grammatical measure that computes children's overall accuracy of four verb tense morphemes. The second measure, percent grammatical utterances (PGU), is a broader grammatical measure that computes children's accuracy in producing grammatical utterances. The extant studies show that FVMC demonstrates acceptable (i.e., 80 to 89% accurate) to good (i.e., 90% accurate or higher) diagnostic accuracy for children between 4;0 (years;months) and 6;11 in conversational or narrative samples. In contrast, PGU yields acceptable to good diagnostic accuracy for children between 3;0 and 8;11 regardless of sample types. Given the diagnostic accuracy shown in the literature, we suggest that FVMC and PGU can be used as one piece of evidence for identifying children with LI in assessment when appropriate. However, FVMC or PGU should not be used as therapy goals directly. Instead, when children are low in FVMC or PGU, we suggest that follow-up analyses should be conducted to determine the verb tense morphemes or grammatical structures that children have difficulty with. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Accuracy of clinical tests in the diagnosis of anterior cruciate ligament injury: a systematic review

    PubMed Central

    2014-01-01

    Background Numerous clinical tests are used in the diagnosis of anterior cruciate ligament (ACL) injury but their accuracy is unclear. The purpose of this study is to evaluate the diagnostic accuracy of clinical tests for the diagnosis of ACL injury. Methods Study Design: Systematic review. The review protocol was registered through PROSPERO (CRD42012002069). Electronic databases (PubMed, MEDLINE, EMBASE, CINAHL) were searched up to 19th of June 2013 to identify diagnostic studies comparing the accuracy of clinical tests for ACL injury to an acceptable reference standard (arthroscopy, arthrotomy, or MRI). Risk of bias was appraised using the QUADAS-2 checklist. Index test accuracy was evaluated using a descriptive analysis of paired likelihood ratios and displayed as forest plots. Results A total of 285 full-text articles were assessed for eligibility, from which 14 studies were included in this review. Included studies were deemed to be clinically and statistically heterogeneous, so a meta-analysis was not performed. Nine clinical tests from the history (popping sound at time of injury, giving way, effusion, pain, ability to continue activity) and four from physical examination (anterior draw test, Lachman’s test, prone Lachman’s test and pivot shift test) were investigated for diagnostic accuracy. Inspection of positive and negative likelihood ratios indicated that none of the individual tests provide useful diagnostic information in a clinical setting. Most studies were at risk of bias and reported imprecise estimates of diagnostic accuracy. Conclusion Despite being widely used and accepted in clinical practice, the results of individual history items or physical tests do not meaningfully change the probability of ACL injury. In contrast combinations of tests have higher diagnostic accuracy; however the most accurate combination of clinical tests remains an area for future research. Clinical relevance Clinicians should be aware of the limitations associated with the use of clinical tests for diagnosis of ACL injury. PMID:25187877

  5. Accuracy of clinical tests in the diagnosis of anterior cruciate ligament injury: a systematic review.

    PubMed

    Swain, Michael S; Henschke, Nicholas; Kamper, Steven J; Downie, Aron S; Koes, Bart W; Maher, Chris G

    2014-01-01

    Numerous clinical tests are used in the diagnosis of anterior cruciate ligament (ACL) injury but their accuracy is unclear. The purpose of this study is to evaluate the diagnostic accuracy of clinical tests for the diagnosis of ACL injury. Systematic review. The review protocol was registered through PROSPERO (CRD42012002069). Electronic databases (PubMed, MEDLINE, EMBASE, CINAHL) were searched up to 19th of June 2013 to identify diagnostic studies comparing the accuracy of clinical tests for ACL injury to an acceptable reference standard (arthroscopy, arthrotomy, or MRI). Risk of bias was appraised using the QUADAS-2 checklist. Index test accuracy was evaluated using a descriptive analysis of paired likelihood ratios and displayed as forest plots. A total of 285 full-text articles were assessed for eligibility, from which 14 studies were included in this review. Included studies were deemed to be clinically and statistically heterogeneous, so a meta-analysis was not performed. Nine clinical tests from the history (popping sound at time of injury, giving way, effusion, pain, ability to continue activity) and four from physical examination (anterior draw test, Lachman's test, prone Lachman's test and pivot shift test) were investigated for diagnostic accuracy. Inspection of positive and negative likelihood ratios indicated that none of the individual tests provide useful diagnostic information in a clinical setting. Most studies were at risk of bias and reported imprecise estimates of diagnostic accuracy. Despite being widely used and accepted in clinical practice, the results of individual history items or physical tests do not meaningfully change the probability of ACL injury. In contrast combinations of tests have higher diagnostic accuracy; however the most accurate combination of clinical tests remains an area for future research. Clinicians should be aware of the limitations associated with the use of clinical tests for diagnosis of ACL injury.

  6. Transbronchial Lung Cryobiopsy and Video-assisted Thoracoscopic Lung Biopsy in the Diagnosis of Diffuse Parenchymal Lung Disease. A Meta-analysis of Diagnostic Test Accuracy.

    PubMed

    Iftikhar, Imran H; Alghothani, Lana; Sardi, Alejandro; Berkowitz, David; Musani, Ali I

    2017-07-01

    Transbronchial lung cryobiopsy is increasingly being used for the assessment of diffuse parenchymal lung diseases. Several studies have shown larger biopsy samples and higher yields compared with conventional transbronchial biopsies. However, the higher risk of bleeding and other complications has raised concerns for widespread use of this modality. To study the diagnostic accuracy and safety profile of transbronchial lung cryobiopsy and compare with video-assisted thoracoscopic surgery (VATS) by reviewing available evidence from the literature. Medline and PubMed were searched from inception until December 2016. Data on diagnostic performance were abstracted by constructing two-by-two contingency tables for each study. Data on a priori selected safety outcomes were collected. Risk of bias was assessed with the Quality Assessment of Diagnostic Accuracy Studies tool. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of transbronchial lung cryobiopsy were 83.7% (76.9-88.8%), 87% (85-89%), and 57% (40-73%), respectively. The pooled diagnostic yield, pooled sensitivity, and pooled specificity of VATS were 92.7% (87.6-95.8%), 91.0% (89-92%), and 58% (31-81%), respectively. The incidence of grade 2 (moderate to severe) endobronchial bleeding after transbronchial lung cryobiopsy and of post-procedural pneumothorax was 4.9% (2.2-10.7%) and 9.5% (5.9-14.9%), respectively. Although the diagnostic test accuracy measures of transbronchial lung cryobiopsy lag behind those of VATS, with an acceptable safety profile and potential cost savings, the former could be considered as an alternative in the evaluation of patients with diffuse parenchymal lung diseases.

  7. Performance of search strategies to retrieve systematic reviews of diagnostic test accuracy from the Cochrane Library.

    PubMed

    Huang, Yuansheng; Yang, Zhirong; Wang, Jing; Zhuo, Lin; Li, Zhixia; Zhan, Siyan

    2016-05-06

    To compare the performance of search strategies to retrieve systematic reviews of diagnostic test accuracy from The Cochrane Library. Databases of CDSR and DARE in the Cochrane Library were searched for systematic reviews of diagnostic test accuracy published between 2008 and 2012 through nine search strategies. Each strategy consists of one group or combination of groups of searching filters about diagnostic test accuracy. Four groups of diagnostic filters were used. The Strategy combing all the filters was used as the reference to determine the sensitivity, precision, and the sensitivity x precision product for another eight Strategies. The reference Strategy retrieved 8029 records, of which 832 were eligible. The strategy only composed of MeSH terms about "accuracy measures" achieved the highest values in both precision (69.71%) and product (52.45%) with a moderate sensitivity (75.24%). The combination of MeSH terms and free text words about "accuracy measures" contributed little to increasing the sensitivity. Strategies composed of filters about "diagnosis" had similar sensitivity but lower precision and product to those composed of filters about "accuracy measures". MeSH term "exp'diagnosis' " achieved the lowest precision (9.78%) and product (7.91%), while its hyponym retrieved only half the number of records at the expense of missing 53 target articles. The precision was negatively correlated with sensitivities among the nine strategies. Compared to the filters about "diagnosis", the filters about "accuracy measures" achieved similar sensitivities but higher precision. When combining both terms, sensitivity of the strategy was enhanced obviously. The combination of MeSH terms and free text words about the same concept seemed to be meaningless for enhancing sensitivity. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  8. Reliability, Validity, and Classification Accuracy of the DSM-5 Diagnostic Criteria for Gambling Disorder and Comparison to DSM-IV.

    PubMed

    Stinchfield, Randy; McCready, John; Turner, Nigel E; Jimenez-Murcia, Susana; Petry, Nancy M; Grant, Jon; Welte, John; Chapman, Heather; Winters, Ken C

    2016-09-01

    The DSM-5 was published in 2013 and it included two substantive revisions for gambling disorder (GD). These changes are the reduction in the threshold from five to four criteria and elimination of the illegal activities criterion. The purpose of this study was to twofold. First, to assess the reliability, validity and classification accuracy of the DSM-5 diagnostic criteria for GD. Second, to compare the DSM-5-DSM-IV on reliability, validity, and classification accuracy, including an examination of the effect of the elimination of the illegal acts criterion on diagnostic accuracy. To compare DSM-5 and DSM-IV, eight datasets from three different countries (Canada, USA, and Spain; total N = 3247) were used. All datasets were based on similar research methods. Participants were recruited from outpatient gambling treatment services to represent the group with a GD and from the community to represent the group without a GD. All participants were administered a standardized measure of diagnostic criteria. The DSM-5 yielded satisfactory reliability, validity and classification accuracy. In comparing the DSM-5 to the DSM-IV, most comparisons of reliability, validity and classification accuracy showed more similarities than differences. There was evidence of modest improvements in classification accuracy for DSM-5 over DSM-IV, particularly in reduction of false negative errors. This reduction in false negative errors was largely a function of lowering the cut score from five to four and this revision is an improvement over DSM-IV. From a statistical standpoint, eliminating the illegal acts criterion did not make a significant impact on diagnostic accuracy. From a clinical standpoint, illegal acts can still be addressed in the context of the DSM-5 criterion of lying to others.

  9. Diagnostic Accuracy of Chinese Medicine Diagnosis Scale of Phlegm and Blood Stasis Syndrome in Coronary Heart Disease: A Study Protocol.

    PubMed

    Liu, Xiao-Qi; Peng, Dan-Hong; Wang, Yan-Ping; Xie, Rong; Chen, Xin-Lin; Yu, Chun-Quan; Li, Xian-Tao

    2018-05-03

    Phlegm and blood stasis syndrome (PBSS) is one of the main syndromes in coronary heart disease (CHD). Syndromes of Chinese medicine (CM) are lack of quantitative and easyimplementation diagnosis standards. To quantify and standardize the diagnosis of PBSS, scales are usually applied. To evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. Six hundred patients with stable angina pectoris of CHD, 300 in case group and 300 in control group, will be recruited from 5 hospitals across China. Diagnosis from 2 experts will be considered as the "gold standard". The study design consists of 2 phases: pilot test is used to evaluate the reliability and validity, and diagnostic test is used to assess the diagnostic accuracy of the scale, including sensitivity, specififi city, likelihood ratio and area under the receiver operator characteristic (ROC) curve. This study will evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. The consensus of 2 experts may not be ideal as a "gold standard", and itself still requires further study. (No. ChiCTR-OOC-15006599).

  10. A Statistical Evaluation of the Diagnostic Performance of MEDAS-The Medical Emergency Decision Assistance System

    PubMed Central

    Georgakis, D. Christine; Trace, David A.; Naeymi-Rad, Frank; Evens, Martha

    1990-01-01

    Medical expert systems require comprehensive evaluation of their diagnostic accuracy. The usefulness of these systems is limited without established evaluation methods. We propose a new methodology for evaluating the diagnostic accuracy and the predictive capacity of a medical expert system. We have adapted to the medical domain measures that have been used in the social sciences to examine the performance of human experts in the decision making process. Thus, in addition to the standard summary measures, we use measures of agreement and disagreement, and Goodman and Kruskal's λ and τ measures of predictive association. This methodology is illustrated by a detailed retrospective evaluation of the diagnostic accuracy of the MEDAS system. In a study using 270 patients admitted to the North Chicago Veterans Administration Hospital, diagnoses produced by MEDAS are compared with the discharge diagnoses of the attending physicians. The results of the analysis confirm the high diagnostic accuracy and predictive capacity of the MEDAS system. Overall, the agreement of the MEDAS system with the “gold standard” diagnosis of the attending physician has reached a 90% level.

  11. Added value of cost-utility analysis in simple diagnostic studies of accuracy: (18)F-fluoromethylcholine PET/CT in prostate cancer staging.

    PubMed

    Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.

  12. The role of serum erythropoietin level and JAK2 V617F allele burden in the diagnosis of polycythaemia vera.

    PubMed

    Ancochea, Agueda; Alvarez-Larrán, Alberto; Morales-Indiano, Cristian; García-Pallarols, Francesc; Martínez-Avilés, Luz; Angona, Anna; Senín, Alicia; Bellosillo, Beatriz; Besses, Carles

    2014-11-01

    Low serum erythropoietin (EPO) is a minor criterion of Polycythaemia Vera (PV) but its diagnostic usefulness relies on studies performed before the discovery of JAK2 V617F mutation. The objective of the present study was to evaluate the diagnostic accuracy of serum EPO and JAK2 V617F allele burden as markers of PV as well as the combination of different diagnostic criteria in 287 patients (99 with PV, 137 with Essential Thrombocythaemia and 51 with non-clonal erythrocytosis). Low EPO showed good diagnostic accuracy as a marker for PV, with the area under the curve (AUC) of the chemiluminescent-enhanced enzyme immunoassay (CEIA) being better than that of radioimmunoassay (RIA) (0·87 and 0·76 for CEIA and RIA, respectively). JAK2 V617F quantification displayed an excellent diagnostic accuracy, with an AUC of 0·95. A haematocrit >52% (males) or >48% (females) plus the presence of the JAK2 V617F mutation had a sensitivity and specificity of 79% and 97%, respectively. Adding low EPO or the JAK2 V617F allele burden did not improve the diagnostic accuracy for PV whereas the inclusion of both improved the sensitivity up to 83% and maintaining 96% specificity. Haematocrit and qualitative JAK2 V617F mutation allow a reliable diagnosis of PV. Incorporation of EPO and/or JAK2 V617F mutant load does not improve the diagnostic accuracy. © 2014 John Wiley & Sons Ltd.

  13. Diagnostic Accuracy of MRI-guided Percutaneous Transthoracic Needle Biopsy of Solitary Pulmonary Nodules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Shangang, E-mail: 1198685580@qq.com; Li, Chengli, E-mail: chenglilichina@yeah.net; Yu, Xuejuan, E-mail: yuxuejuan2011@126.com

    2015-04-15

    ObjectiveThe purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs).MethodsRetrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The final diagnosis was established by surgical pathology of the nodule or clinical and imaging follow-up. Pneumothorax rate and diagnostic accuracy were compared between two groups according to nodule diameter (≤2 vs. >2 cm) using χ{sup 2} chest and Fisher’s exact test, respectively.ResultsThe success rate of single puncture was 95.6 %. Twelve (17.4 %) patients had pneumothorax, with 1 (1.4 %) requiring chestmore » tube insertion. Mild hemoptysis occurred in 7 (7.2 %) patients. All of the sample material was sufficient for histological diagnostic evaluation. Pathological analysis of biopsy specimens showed 46 malignant, 22 benign, and 1 nondiagnostic nodule. The final diagnoses were 49 malignant nodules and 20 benign nodules basing on postoperative histopathology and clinical follow-up data. One nondiagnostic sample was excluded from calculating diagnostic performance. A sensitivity, specificity, accuracy, positive predictive value, and negative predictive value in diagnosing SPNs were 95.8, 100, 97.0, 100, and 90.9 %, respectively. Pneumothorax rate, diagnostic sensitivity, and accuracy were not significantly different between the two groups (P > 0.05).ConclusionsMRI-guided PTNB is safe, feasible, and high accurate diagnostic technique for pathologic diagnosis of pulmonary nodules.« less

  14. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    PubMed

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.

  15. Estimation of diagnostic test accuracy without full verification: a review of latent class methods

    PubMed Central

    Collins, John; Huynh, Minh

    2014-01-01

    The performance of a diagnostic test is best evaluated against a reference test that is without error. For many diseases, this is not possible, and an imperfect reference test must be used. However, diagnostic accuracy estimates may be biased if inaccurately verified status is used as the truth. Statistical models have been developed to handle this situation by treating disease as a latent variable. In this paper, we conduct a systematized review of statistical methods using latent class models for estimating test accuracy and disease prevalence in the absence of complete verification. PMID:24910172

  16. Diagnostic accuracy of imaging devices in glaucoma: A meta-analysis.

    PubMed

    Fallon, Monica; Valero, Oliver; Pazos, Marta; Antón, Alfonso

    Imaging devices such as the Heidelberg retinal tomograph-3 (HRT3), scanning laser polarimetry (GDx), and optical coherence tomography (OCT) play an important role in glaucoma diagnosis. A systematic search for evidence-based data was performed for prospective studies evaluating the diagnostic accuracy of HRT3, GDx, and OCT. The diagnostic odds ratio (DOR) was calculated. To compare the accuracy among instruments and parameters, a meta-analysis considering the hierarchical summary receiver-operating characteristic model was performed. The risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Studies in the context of screening programs were used for qualitative analysis. Eighty-six articles were included. The DOR values were 29.5 for OCT, 18.6 for GDx, and 13.9 for HRT. The heterogeneity analysis demonstrated statistically a significant influence of degree of damage and ethnicity. Studies analyzing patients with earlier glaucoma showed poorer results. The risk of bias was high for patient selection. Screening studies showed lower sensitivity values and similar specificity values when compared with those included in the meta-analysis. The classification capabilities of GDx, HRT, and OCT were high and similar across the 3 instruments. The highest estimated DOR was obtained with OCT. Diagnostic accuracy could be overestimated in studies including prediagnosed groups of subjects. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Is diagnostic accuracy for detecting pulmonary nodules in chest CT reduced after a long day of reading?

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.; Berbaum, Kevin S.; Caldwell, Robert; Schartz, Kevin M.

    2012-02-01

    Radiologists are reading more cases with more images, especially in CT and MRI and thus working longer hours than ever before. There have been concerns raised regarding fatigue and whether it impacts diagnostic accuracy. This study measured the impact of reader visual fatigue by assessing symptoms, visual strain via dark focus of accommodation, and diagnostic accuracy. Twenty radiologists and 20 radiology residents were given two diagnostic performance tests searching CT chest sequences for a solitary pulmonary nodule before (rested) and after (tired) a day of clinical reading. 10 cases used free search and navigation, and the other 100 cases used preset scrolling speed and duration. Subjects filled out the Swedish Occupational Fatigue Inventory (SOFI) and the oculomotor strain subscale of the Simulator Sickness Questionnaire (SSQ) before each session. Accuracy was measured using ROC techniques. Using Swensson's technique yields an ROC area = 0.86 rested vs. 0.83 tired, p (one-tailed) = 0.09. Using Swensson's LROC technique yields an area = 0.73 rested vs. 0.66 tired, p (one-tailed) = 0.09. Using Swensson's Loc Accuracy technique yields an area = 0.77 rested vs. 0.72 tired, p (one-tailed) = 0.13). Subjective measures of fatigue increased significantly from early to late reading. To date, the results support our findings with static images and detection of bone fractures. Radiologists at the end of a long work day experience greater levels of measurable visual fatigue or strain, contributing to a decrease in diagnostic accuracy. The decrease in accuracy was not as great however as with static images.

  18. Effect of varying displays and room illuminance on caries diagnostic accuracy in digital dental radiographs.

    PubMed

    Pakkala, T; Kuusela, L; Ekholm, M; Wenzel, A; Haiter-Neto, F; Kortesniemi, M

    2012-01-01

    In clinical practice, digital radiographs taken for caries diagnostics are viewed on varying types of displays and usually in relatively high ambient lighting (room illuminance) conditions. Our purpose was to assess the effect of room illuminance and varying display types on caries diagnostic accuracy in digital dental radiographs. Previous studies have shown that the diagnostic accuracy of caries detection is significantly better in reduced lighting conditions. Our hypothesis was that higher display luminance could compensate for this in higher ambient lighting conditions. Extracted human teeth with approximal surfaces clinically ranging from sound to demineralized were radiographed and evaluated by 3 observers who detected carious lesions on 3 different types of displays in 3 different room illuminance settings ranging from low illumination, i.e. what is recommended for diagnostic viewing, to higher illumination levels corresponding to those found in an average dental office. Sectioning and microscopy of the teeth validated the presence or absence of a carious lesion. Sensitivity, specificity and accuracy were calculated for each modality and observer. Differences were estimated by analyzing the binary data assuming the added effects of observer and modality in a generalized linear model. The observers obtained higher sensitivities in lower illuminance settings than in higher illuminance settings. However, this was related to a reduction in specificity, which meant that there was no significant difference in overall accuracy. Contrary to our hypothesis, there were no significant differences between the accuracy of different display types. Therefore, different displays and room illuminance levels did not affect the overall accuracy of radiographic caries detection. Copyright © 2012 S. Karger AG, Basel.

  19. Diagnostic potential of Fasciola gigantica-derived 14.5 kDa fatty acid binding protein in the immunodiagnosis of bubaline fascioliasis.

    PubMed

    Allam, G; Bauomy, I R; Hemyeda, Z M; Diab, T M; Sakran, T F

    2013-06-01

    The 14.5 kDa fatty acid binding protein (FABP) was isolated from the crude extract of adult Fasciola gigantica worms. Polyclonal anti-FABP IgG was generated in rabbits immunized with prepared FABP antigen. Sandwich enzyme-linked immunosorbent assay (ELISA) was applied to detect coproantigen in stools and circulating Fasciola antigen (CA) in sera of 126 water buffaloes by using purified and horseradish peroxidase (HRP)-conjugated anti-FABP IgG. Sandwich ELISA sensitivity was 96.97% and 94.95%; while specificity was 94.12% and 82.35% for coproantigen and CA detection, respectively. However, sensitivity and specificity of the Kato-Katz technique was 73.74% and 100%, respectively. The diagnostic efficacy of sandwich ELISA was 96.55% and 93.1% for coproantigen and CA detection, respectively. In contrast, the diagnostic efficacy of the Kato-Katz technique was 77.59%. In conclusion, these results demonstrate that the purified 14.5 kDa FABP provides a more suitable antigen for immunodiagnosis of early and current bubaline fascioliasis by using sandwich ELISA.

  20. The ATLAS PanDA Monitoring System and its Evolution

    NASA Astrophysics Data System (ADS)

    Klimentov, A.; Nevski, P.; Potekhin, M.; Wenaus, T.

    2011-12-01

    The PanDA (Production and Distributed Analysis) Workload Management System is used for ATLAS distributed production and analysis worldwide. The needs of ATLAS global computing imposed challenging requirements on the design of PanDA in areas such as scalability, robustness, automation, diagnostics, and usability for both production shifters and analysis users. Through a system-wide job database, the PanDA monitor provides a comprehensive and coherent view of the system and job execution, from high level summaries to detailed drill-down job diagnostics. It is (like the rest of PanDA) an Apache-based Python application backed by Oracle. The presentation layer is HTML code generated on the fly in the Python application which is also responsible for managing database queries. However, this approach is lacking in user interface flexibility, simplicity of communication with external systems, and ease of maintenance. A decision was therefore made to migrate the PanDA monitor server to Django Web Application Framework and apply JSON/AJAX technology in the browser front end. This allows us to greatly reduce the amount of application code, separate data preparation from presentation, leverage open source for tools such as authentication and authorization mechanisms, and provide a richer and more dynamic user experience. We describe our approach, design and initial experience with the migration process.

  1. Administrative database code accuracy did not vary notably with changes in disease prevalence.

    PubMed

    van Walraven, Carl; English, Shane; Austin, Peter C

    2016-11-01

    Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Bayesian modeling and inference for diagnostic accuracy and probability of disease based on multiple diagnostic biomarkers with and without a perfect reference standard.

    PubMed

    Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A

    2016-03-15

    The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Is there any evidence for the validity of diagnostic criteria used for accommodative and nonstrabismic binocular dysfunctions?

    PubMed Central

    Cacho-Martínez, Pilar; García-Muñoz, Ángel; Ruiz-Cantero, María Teresa

    2013-01-01

    Purpose To analyze the diagnostic criteria used in the scientific literature published in the past 25 years for accommodative and nonstrabismic binocular dysfunctions and to explore if the epidemiological analysis of diagnostic validity has been used to propose which clinical criteria should be used for diagnostic purposes. Methods We carried out a systematic review of papers on accommodative and non-strabic binocular disorders published from 1986 to 2012 analysing the MEDLINE, CINAHL, PsycINFO and FRANCIS databases. We admitted original articles about diagnosis of these anomalies in any population. We identified 839 articles and 12 studies were included. The quality of included articles was assessed using the QUADAS-2 tool. Results The review shows a wide range of clinical signs and cut-off points between authors. Only 3 studies (regarding accommodative anomalies) assessed diagnostic accuracy of clinical signs. Their results suggest using the accommodative amplitude and monocular accommodative facility for diagnosing accommodative insufficiency and a high positive relative accommodation for accommodative excess. The remaining 9 articles did not analyze diagnostic accuracy, assessing a diagnosis with the criteria the authors considered. We also found differences between studies in the way of considering patients’ symptomatology. 3 studies of 12 analyzed, performed a validation of a symptom survey used for convergence insufficiency. Conclusions Scientific literature reveals differences between authors according to diagnostic criteria for accommodative and nonstrabismic binocular dysfunctions. Diagnostic accuracy studies show that there is only certain evidence for accommodative conditions. For binocular anomalies there is only evidence about a validated questionnaire for convergence insufficiency with no data of diagnostic accuracy. PMID:24646897

  4. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    PubMed

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  5. The biasing effect of clinical history on physical examination diagnostic accuracy.

    PubMed

    Sibbald, Matthew; Cavalcanti, Rodrigo B

    2011-08-01

    Literature on diagnostic test interpretation has shown that access to clinical history can both enhance diagnostic accuracy and increase diagnostic error. Knowledge of clinical history has also been shown to enhance the more complex cognitive task of physical examination diagnosis, possibly by enabling early hypothesis generation. However, it is unclear whether clinicians adhere to these early hypotheses in the face of unexpected physical findings, thus resulting in diagnostic error. A sample of 180 internal medicine residents received a short clinical history and conducted a cardiac physical examination on a high-fidelity simulator. Resident Doctors (Residents) were randomised to three groups based on the physical findings in the simulator. The concordant group received physical examination findings consistent with the diagnosis that was most probable based on the clinical history. Discordant groups received findings associated with plausible alternative diagnoses which either lacked expected findings (indistinct discordant) or contained unexpected findings (distinct discordant). Physical examination diagnostic accuracy and physical examination findings were analysed. Physical examination diagnostic accuracy varied significantly among groups (75 ± 44%, 2 ± 13% and 31 ± 47% in the concordant, indistinct discordant and distinct discordant groups, respectively (F(2,177)  = 53, p < 0.0001). Of the 115 Residents who were diagnostically unsuccessful, 33% adhered to their original incorrect hypotheses. Residents verbalised an average of 12 findings (interquartile range: 10-14); 58 ± 17% were correct and the percentage of correct findings was similar in all three groups (p = 0.44). Residents showed substantially decreased diagnostic accuracy when faced with discordant physical findings. The majority of trainees given discordant physical findings rejected their initial hypotheses, but were still diagnostically unsuccessful. These results suggest that overcoming the bias induced by a misleading clinical history may involve two independent steps: rejection of the incorrect initial hypothesis, and selection of the correct diagnosis. Educational strategies focused solely on prompting clinicians to re-examine their hypotheses may be insufficient to reduce diagnostic error. © Blackwell Publishing Ltd 2011.

  6. Field evaluation of descent advisor trajectory prediction accuracy

    DOT National Transportation Integrated Search

    1996-07-01

    The Descent Advisor (DA) automation tool has undergone a series of field tests : at the Denver Air Route Traffic Control Center to study the feasibility of : DA-based clearances and procedures. The latest evaluation, conducted in the : fall of 1995, ...

  7. The Clinical Usefulness of Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy for Rectal and Perirectal Lesions

    PubMed Central

    Soh, Jae Seung; Lee, Ho-Su; Lee, Seohyun; Bae, Jungho; Lee, Hyo Jeong; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho

    2015-01-01

    Background/Aims Endoscopic ultrasound-guided fine needle aspiration and/or biopsy (EUS-FNA/B) have been used to diagnose subepithelial tumors (SETs) and extraluminal lesions in the gastrointestinal tract. Our group previously reported the usefulness of EUS-FNA/B for rectal and perirectal lesions. This study reports our expanded experience with EUS-FNA/B for rectal and perirectal lesions in terms of diagnostic accuracy and safety. We also included our new experience with EUS-FNB using the recently introduced ProCore needle. Methods From April 2009 to March 2014, EUS-FNA/B for rectal and perirectal lesions was performed in 30 consecutive patients. We evaluated EUS-FNA/B performance by comparing histological diagnoses with final results. We also investigated factors affecting diagnostic accuracy. Results Among 10 patients with SETs, EUS-FNA/B specimen results revealed a gastrointestinal stromal tumor in 4 patients and malignant lymphoma in 1 patient. The diagnostic accuracy of EUS-FNA/B was 50% for SETs (5/10). Among 20 patients with non-SET lesions, 8 patients were diagnosed with malignant disease and 7 were diagnosed with benign disease based on both EUS-FNA/B and the final results. The diagnostic accuracy of EUS-FNA/B for non-SET lesions was 75% (15/20). The size of lesions was the only factor related to diagnostic accuracy (P=0.027). Two complications of mild fever and asymptomatic pneumoperitoneum occurred after EUS-FNA/B. Conclusions The overall diagnostic accuracy of EUS-FNA/B for rectal and perirectal lesions was 67% (20/30). EUS-FNA/B is a clinically useful method for cytological and histological diagnoses of rectal and perirectal lesions. PMID:25931998

  8. Diagnostic accuracy of 3D-transvaginal ultrasound in detecting uterine cavity abnormalities in infertile patients as compared with hysteroscopy.

    PubMed

    Apirakviriya, Chayanis; Rungruxsirivorn, Tassawan; Phupong, Vorapong; Wisawasukmongchol, Wirach

    2016-05-01

    To assess diagnostic accuracy of 3D transvaginal ultrasound (3D-TVS) compared with hysteroscopy in detecting uterine cavity abnormalities in infertile women. This prospective observational cross-sectional study was conducted during the July 2013 to December 2013 study period. Sixty-nine women with infertility were enrolled. In the mid to late follicular phase of each subject's menstrual cycle, 3D transvaginal ultrasound and hysteroscopy were performed on the same day in each patient. Hysteroscopy is widely considered to be the gold standard method for investigation of the uterine cavity. Uterine cavity characteristics and abnormalities were recorded. Diagnostic accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and positive and negative likelihood ratios were evaluated. Hysteroscopy was successfully performed in all subjects. Hysteroscopy diagnosed pathological findings in 22 of 69 cases (31.8%). There were 18 endometrial polyps, 3 submucous myomas, and 1 septate uterus. Three-dimensional transvaginal ultrasound in comparison with hysteroscopy had 84.1% diagnostic accuracy, 68.2% sensitivity, 91.5% specificity, 79% positive predictive value, and 86% negative predictive value. The positive and negative likelihood ratios were 8.01 and 0.3, respectively. 3D-TVS successfully detected every case of submucous myoma and uterine anomaly. For detection of endometrial polyps, 3D-TVS had 61.1% sensitivity, 91.5% specificity, and 83.1% diagnostic accuracy. 3D-TVS demonstrated 84.1% diagnostic accuracy for detecting uterine cavity abnormalities in infertile women. A significant percentage of infertile patients had evidence of uterine cavity pathology. Hysteroscopy is, therefore, recommended for accurate detection and diagnosis of uterine cavity lesion. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Low clinical diagnostic accuracy of early vs advanced Parkinson disease: clinicopathologic study.

    PubMed

    Adler, Charles H; Beach, Thomas G; Hentz, Joseph G; Shill, Holly A; Caviness, John N; Driver-Dunckley, Erika; Sabbagh, Marwan N; Sue, Lucia I; Jacobson, Sandra A; Belden, Christine M; Dugger, Brittany N

    2014-07-29

    Determine diagnostic accuracy of a clinical diagnosis of Parkinson disease (PD) using neuropathologic diagnosis as the gold standard. Data from the Arizona Study of Aging and Neurodegenerative Disorders were used to determine the predictive value of a clinical PD diagnosis, using 2 clinical diagnostic confidence levels, PossPD (never treated or not clearly responsive) and ProbPD (responsive to medications). Neuropathologic diagnosis was the gold standard. Based on first visit, 9 of 34 (26%) PossPD cases had neuropathologically confirmed PD while 80 of 97 (82%) ProbPD cases had confirmed PD. PD was confirmed in 8 of 15 (53%) ProbPD cases with <5 years of disease duration and 72 of 82 (88%) with ≥5 years of disease duration. Using final diagnosis at time of death, 91 of 107 (85%) ProbPD cases had confirmed PD. Clinical variables that improved diagnostic accuracy were medication response, motor fluctuations, dyskinesias, and hyposmia. Using neuropathologic findings of PD as the gold standard, this study establishes the novel findings of only 26% accuracy for a clinical diagnosis of PD in untreated or not clearly responsive subjects, 53% accuracy in early PD responsive to medication (<5 years' duration), and >85% diagnostic accuracy of longer duration, medication-responsive PD. Caution is needed when interpreting clinical studies of PD, especially studies of early disease that do not have autopsy confirmation. The need for a tissue or other diagnostic biomarker is reinforced. This study provides Class II evidence that a clinical diagnosis of PD identifies patients who will have pathologically confirmed PD with a sensitivity of 88% and specificity of 68%. © 2014 American Academy of Neurology.

  10. Diagnostic Accuracy of the Slump Test for Identifying Neuropathic Pain in the Lower Limb.

    PubMed

    Urban, Lawrence M; MacNeil, Brian J

    2015-08-01

    Diagnostic accuracy study with nonconsecutive enrollment. To assess the diagnostic accuracy of the slump test for neuropathic pain (NeP) in those with low to moderate levels of chronic low back pain (LBP), and to determine whether accuracy of the slump test improves by adding anatomical or qualitative pain descriptors. Neuropathic pain has been linked with poor outcomes, likely due to inadequate diagnosis, which precludes treatment specific for NeP. Current diagnostic approaches are time consuming or lack accuracy. A convenience sample of 21 individuals with LBP, with or without radiating leg pain, was recruited. A standardized neurosensory examination was used to determine the reference diagnosis for NeP. Afterward, the slump test was administered to all participants. Reports of pain location and quality produced during the slump test were recorded. The neurosensory examination designated 11 of the 21 participants with LBP/sciatica as having NeP. The slump test displayed high sensitivity (0.91), moderate specificity (0.70), a positive likelihood ratio of 3.03, and a negative likelihood ratio of 0.13. Adding the criterion of pain below the knee significantly increased specificity to 1.00 (positive likelihood ratio = 11.9). Pain-quality descriptors did not improve diagnostic accuracy. The slump test was highly sensitive in identifying NeP within the study sample. Adding a pain-location criterion improved specificity. Combining the diagnostic outcomes was very effective in identifying all those without NeP and half of those with NeP. Limitations arising from the small and narrow spectrum of participants with LBP/sciatica sampled within the study prevent application of the findings to a wider population. Diagnosis, level 4-.

  11. Comparison of Laser Scanning Diagnostic Devices for Early Glaucoma Detection.

    PubMed

    Schulze, Andreas; Lamparter, Julia; Pfeiffer, Norbert; Berisha, Fatmire; Schmidtmann, Irene; Hoffmann, Esther M

    2015-08-01

    To compare the diagnostic accuracy and to evaluate the correlation of optic nerve head and retinal nerve fiber layer thickness values between Fourier-Domain optical coherence tomography (FD-OCT), confocal scanning laser ophthalmoscopy (CSLO), and scanning laser polarimetry (SLP) for early glaucoma detection. Ninety-three patients with early open-angle glaucoma, 58 patients with ocular hypertension, and 60 healthy control subjects were included in this observational, cross-sectional study. All study participants underwent FD-OCT (RTVue-100), CSLO (HRT3), and SLP (GDx VCC) imaging of the optic nerve head and the retinal nerve fiber layer. Area under the receiver operating characteristic curves (AUROC) and Bland-Altman analysis were performed. The parameters with the highest diagnostic accuracy were found for FD-OCT cup-to-disc ratio (AUROC=0.841), for SLP NFI (AUROC=0.835), and for CSLO cup-to-disc ratio (AUROC=0.789). Diagnostic accuracy of the best CSLO and SLP parameter was similar (P=0.259). There was a small statistically significant difference between the best CSLO and FD-OCT parameters for differentiating between glaucoma and healthy eyes (P=0.047). FD-OCT and SLP have a similarly good diagnostic ability to distinguish between early glaucoma and healthy subjects. The diagnostic accuracy of CSLO was comparable with SLP and marginally lower compared with FD-OCT.

  12. Instrument for evaluation of sedentary lifestyle in patients with high blood pressure.

    PubMed

    Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; de Araujo, Thelma Leite; Guedes, Nirla Gomes; Martins, Larissa Castelo Guedes; Teixeira, Iane Ximenes

    2015-01-01

    this article describes the diagnostic accuracy of the International Physical Activity Questionnaire to identify the nursing diagnosis of sedentary lifestyle. a diagnostic accuracy study was developed with 240 individuals with established high blood pressure. The analysis of diagnostic accuracy was based on measures of sensitivity, specificity, predictive values, likelihood ratios, efficiency, diagnostic odds ratio, Youden index, and area under the receiver-operating characteristic curve. statistical differences between genders were observed for activities of moderate intensity and for total physical activity. Age was negatively correlated with activities of moderate intensity and total physical activity. the analysis of area under the receiver-operating characteristic curve for moderate intensity activities, walking, and total physical activity showed that the International Physical Activity Questionnaire present moderate capacity to correctly classify individuals with and without sedentary lifestyle.

  13. Estimating Classification Consistency and Accuracy for Cognitive Diagnostic Assessment

    ERIC Educational Resources Information Center

    Cui, Ying; Gierl, Mark J.; Chang, Hua-Hua

    2012-01-01

    This article introduces procedures for the computation and asymptotic statistical inference for classification consistency and accuracy indices specifically designed for cognitive diagnostic assessments. The new classification indices can be used as important indicators of the reliability and validity of classification results produced by…

  14. Can mandibular bone resorption predict hip fracture in elderly women? A systematic review of diagnostic test accuracy.

    PubMed

    Devlin, Hugh; Whelton, Christopher

    2015-09-01

    The aim of this systematic review was to determine the diagnostic accuracy of the mandibular cortical width measurements and porosity in detecting hip osteoporosis. All of the included studies used measurements on panoramic radiographs. Studies were included if they compared the radiographic measurements (or index tests) with central dual energy X-ray absorptiometry (DXA) of the hip as the reference standard. A measure of diagnostic accuracy such as sensitivity and specificity or area under the receiver operating characteristic curve was also required for inclusion. Seven studies were identified. Meta-analysis was not possible because of the heterogeneity of the studies. The studies all demonstrated moderate diagnostic accuracy. If a patient with a thin or porous mandibular cortex is identified by a chance radiographic finding, additional clinical risk factors need to be considered and the patient referred for further investigation with DXA where necessary. © 2013 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  15. Evaluation of the International Consensus Guidelines for the Surgical Resection of Intraductal Papillary Mucinous Neoplasms.

    PubMed

    Tsukagoshi, Mariko; Araki, Kenichiro; Saito, Fumiyoshi; Kubo, Norio; Watanabe, Akira; Igarashi, Takamichi; Ishii, Norihiro; Yamanaka, Takahiro; Shirabe, Ken; Kuwano, Hiroyuki

    2018-04-01

    International consensus guidelines for intraductal papillary mucinous neoplasms (IPMNs) were revised in 2012. We aimed to evaluate the clinical utility of each predictor in the 2006 and 2012 guidelines and validate the diagnostic value and surgical indications. Forty-two patients with surgically resected IPMNs were included. Each predictor was applied to evaluate its diagnostic value. The 2012 guidelines had greater accuracy for invasive carcinoma than the 2006 guidelines (64.3 vs. 31.0%). Moreover, the accuracy for high-grade dysplasia was also increased (48.6 vs. 77.1%). When the main pancreatic duct (MPD) size ≥8 mm was substituted for MPD size ≥10 mm in the 2012 guidelines, the accuracy for high-grade dysplasia was 80.0%. The 2012 guidelines exhibited increased diagnostic accuracy for invasive IPMN. It is important to consider surgical resection prior to invasive carcinoma, and high-risk stigmata might be a useful diagnostic criterion. Furthermore, MPD size ≥8 mm may be predictive of high-grade dysplasia.

  16. Impact of time-resolved MRA on diagnostic accuracy in patients with symptomatic peripheral artery disease of the calf station.

    PubMed

    Hansmann, Jan; Michaely, Henrik J; Morelli, John N; Diehl, Steffen J; Meyer, Mathias; Schoenberg, Stefan O; Attenberger, Ulrike I

    2013-12-01

    The purpose of this article is to evaluate the added diagnostic accuracy of time-resolved MR angiography (MRA) of the calves compared with continuous-table-movement MRA in patients with symptomatic lower extremity peripheral artery disease (PAD) using digital subtraction angiography (DSA) correlation. Eighty-four consecutive patients with symptomatic PAD underwent a low-dose 3-T MRA protocol, consisting of continuous-table-movement MRA, acquired from the diaphragm to the calves, and an additional time-resolved MRA of the calves; 0.1 mmol/kg body weight (bw) of contrast material was used (0.07 mmol/kg bw for continuous-table-movement MRA and 0.03 mmol/kg bw for time-resolved MRA). Two radiologists rated image quality on a 4-point scale and stenosis degree on a 3-point scale. An additional assessment determined the degree of venous contamination and whether time-resolved MRA improved diagnostic confidence. The accuracy of stenosis gradation with continuous-table-movement and time-resolved MRA was compared with that of DSA as a correlation. Overall diagnostic accuracy was calculated for continuous-table-movement and time-resolved MRA. Median image quality was rated as good for 578 vessel segments with continuous-table-movement MRA and as excellent for 565 vessel segments with time-resolved MRA. Interreader agreement was excellent (κ = 0.80-0.84). Venous contamination interfered with diagnosis in more than 60% of continuous-table-movement MRA examinations. The degree of stenosis was assessed for 340 vessel segments. The diagnostic accuracies (continuous-table-movement MRA/time-resolved MRA) combined for the readers were obtained for the tibioperoneal trunk (84%/93%), anterior tibial (69%/87%), posterior tibial (85%/91%), and peroneal (67%/81%) arteries. The addition of time-resolved MRA improved diagnostic confidence in 69% of examinations. The addition of time-resolved MRA at the calf station improves diagnostic accuracy over continuous-table-movement MRA alone in symptomatic patients with PAD.

  17. Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis.

    PubMed

    Iannaccone, Mario; Gili, Sebastiano; De Filippo, Ovidio; D'Amico, Salvatore; Gagliardi, Marco; Bertaina, Maurizio; Mazzilli, Silvia; Rettegno, Sara; Bongiovanni, Federica; Gatti, Paolo; Ugo, Fabrizio; Boccuzzi, Giacomo G; Colangelo, Salvatore; Prato, Silvia; Moretti, Claudio; D'Amico, Maurizio; Noussan, Patrizia; Garbo, Roberto; Hildick-Smith, David; Gaita, Fiorenzo; D'Ascenzo, Fabrizio

    2018-01-01

    Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

  18. Repeated significance tests of linear combinations of sensitivity and specificity of a diagnostic biomarker

    PubMed Central

    Wu, Mixia; Shu, Yu; Li, Zhaohai; Liu, Aiyi

    2016-01-01

    A sequential design is proposed to test whether the accuracy of a binary diagnostic biomarker meets the minimal level of acceptance. The accuracy of a binary diagnostic biomarker is a linear combination of the marker’s sensitivity and specificity. The objective of the sequential method is to minimize the maximum expected sample size under the null hypothesis that the marker’s accuracy is below the minimal level of acceptance. The exact results of two-stage designs based on Youden’s index and efficiency indicate that the maximum expected sample sizes are smaller than the sample sizes of the fixed designs. Exact methods are also developed for estimation, confidence interval and p-value concerning the proposed accuracy index upon termination of the sequential testing. PMID:26947768

  19. Diagnostic accuracy research in glaucoma is still incompletely reported: An application of Standards for Reporting of Diagnostic Accuracy Studies (STARD) 2015.

    PubMed

    Michelessi, Manuele; Lucenteforte, Ersilia; Miele, Alba; Oddone, Francesco; Crescioli, Giada; Fameli, Valeria; Korevaar, Daniël A; Virgili, Gianni

    2017-01-01

    Research has shown a modest adherence of diagnostic test accuracy (DTA) studies in glaucoma to the Standards for Reporting of Diagnostic Accuracy Studies (STARD). We have applied the updated 30-item STARD 2015 checklist to a set of studies included in a Cochrane DTA systematic review of imaging tools for diagnosing manifest glaucoma. Three pairs of reviewers, including one senior reviewer who assessed all studies, independently checked the adherence of each study to STARD 2015. Adherence was analyzed on an individual-item basis. Logistic regression was used to evaluate the effect of publication year and impact factor on adherence. We included 106 DTA studies, published between 2003-2014 in journals with a median impact factor of 2.6. Overall adherence was 54.1% for 3,286 individual rating across 31 items, with a mean of 16.8 (SD: 3.1; range 8-23) items per study. Large variability in adherence to reporting standards was detected across individual STARD 2015 items, ranging from 0 to 100%. Nine items (1: identification as diagnostic accuracy study in title/abstract; 6: eligibility criteria; 10: index test (a) and reference standard (b) definition; 12: cut-off definitions for index test (a) and reference standard (b); 14: estimation of diagnostic accuracy measures; 21a: severity spectrum of diseased; 23: cross-tabulation of the index and reference standard results) were adequately reported in more than 90% of the studies. Conversely, 10 items (3: scientific and clinical background of the index test; 11: rationale for the reference standard; 13b: blinding of index test results; 17: analyses of variability; 18; sample size calculation; 19: study flow diagram; 20: baseline characteristics of participants; 28: registration number and registry; 29: availability of study protocol; 30: sources of funding) were adequately reported in less than 30% of the studies. Only four items showed a statistically significant improvement over time: missing data (16), baseline characteristics of participants (20), estimates of diagnostic accuracy (24) and sources of funding (30). Adherence to STARD 2015 among DTA studies in glaucoma research is incomplete, and only modestly increasing over time.

  20. Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.

    PubMed

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren; Cook, Chad

    2013-08-01

    Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. 3a.

  1. Preclinical study of diagnostic performances of contrast-enhanced spectral mammography versus MRI for breast diseases in China.

    PubMed

    Wang, Qingguo; Li, Kangan; Wang, Lihui; Zhang, Jianbing; Zhou, Zhiguo; Feng, Yan

    2016-01-01

    To evaluate diagnostic performances of CESM for breast diseases with comparison to breast MRI in China. Sixty-eight patients with 77 breast lesions underwent MR and CESM. Two radiologists interpreted either MRI or CESM images, separately and independently. BI-RADS 1-3 and BI-RADS 4-5 were classified into the suspicious benign and suspicious malignant groups. Diagnostic accuracy parameters were calculated. Receiver operating characteristic (ROC) curves were constructed for the two modalities. The agreement and correlation between maximum lesion diameter based on CESM and MRI, or CESM and pathology were analyzed. Diagnostic accuracy parameters for CESM were sensitivity 95.8 %, specificity 65.5 %, PPV 82.1 %, NPV 90.5 % and accuracy 84.4 %. The diagnostic accuracy parameters for breast MRI were sensitivity 93.8 %, specificity 82.8 %, PPV 88.2 %, NPV 92.3 %and accuracy 89.6 %. Area under the curve (AUC) of ROC was 0.96 for breast MRI and 0.88 for CESM. The Bland-Altman plots showed a mean difference of 0.7 mm with 95 % limits of agreement of 11.4 mm in tumor diameter measured using CESM and breast MRI. The differences of size measurement between CESM and breast MRI were significant, whereas no difference was observed between CESM and pathology as well as between breast MRI and pathology. The better correlation with pathological results was found in CESM than breast MRI. Our study demonstrates that CESM possesses better diagnostic performances than breast MRI in terms of diagnostic sensitivity and lesion size assessment. And CESM is a good alternative method of screening breast cancer in high-risk people.

  2. A meta-analysis of use of Prostate Imaging Reporting and Data System Version 2 (PI-RADS V2) with multiparametric MR imaging for the detection of prostate cancer.

    PubMed

    Zhang, Li; Tang, Min; Chen, Sipan; Lei, Xiaoyan; Zhang, Xiaoling; Huan, Yi

    2017-12-01

    This meta-analysis was undertaken to review the diagnostic accuracy of PI-RADS V2 for prostate cancer (PCa) detection with multiparametric MR (mp-MR). A comprehensive literature search of electronic databases was performed by two observers independently. Inclusion criteria were original research using the PI-RADS V2 system in reporting prostate MRI. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Data necessary to complete 2 × 2 contingency tables were obtained from the included studies. Thirteen studies (2,049 patients) were analysed. This is an initial meta-analysis of PI-RADs V2 and the overall diagnostic accuracy in diagnosing PCa was as follows: pooled sensitivity, 0.85 (0.78-0.91); pooled specificity, 0.71 (0.60-0.80); pooled positive likelihood ratio (LR+), 2.92 (2.09-4.09); pooled negative likelihood ratio (LR-), 0.21 (0.14-0.31); pooled diagnostic odds ratio (DOR), 14.08 (7.93-25.01), respectively. Positive predictive values ranged from 0.54 to 0.97 and negative predictive values ranged from 0.26 to 0.92. Currently available evidence indicates that PI-RADS V2 appears to have good diagnostic accuracy in patients with PCa lesions with high sensitivity and moderate specificity. However, no recommendation regarding the best threshold can be provided because of heterogeneity. • PI-RADS V2 shows good diagnostic accuracy for PCa detection. • Initially pooled specificity of PI-RADS v2 remains moderate. • PCa detection is increased by experienced radiologists. • There is currently a high heterogeneity in prostate diagnostics with MRI.

  3. Value of physical tests in diagnosing cervical radiculopathy: a systematic review.

    PubMed

    Thoomes, Erik J; van Geest, Sarita; van der Windt, Danielle A; Falla, Deborah; Verhagen, Arianne P; Koes, Bart W; Thoomes-de Graaf, Marloes; Kuijper, Barbara; Scholten-Peeters, Wendy G M; Vleggeert-Lankamp, Carmen L

    2018-01-01

    In clinical practice, the diagnosis of cervical radiculopathy is based on information from the patient's history, physical examination, and diagnostic imaging. Various physical tests may be performed, but their diagnostic accuracy is unknown. This study aimed to summarize and update the evidence on diagnostic performance of tests carried out during a physical examination for the diagnosis of cervical radiculopathy. A review of the accuracy of diagnostic tests was carried out. The study sample comprised diagnostic studies comparing results of tests performed during a physical examination in diagnosing cervical radiculopathy with a reference standard of imaging or surgical findings. Sensitivity, specificity, likelihood ratios are presented, together with pooled results for sensitivity and specificity. A literature search up to March 2016 was performed in CENTRAL, PubMed (MEDLINE), Embase, CINAHL, Web of Science, and Google Scholar. The methodological quality of studies was assessed using the QUADAS-2. Five diagnostic accuracy studies were identified. Only Spurling's test was evaluated in more than one study, showing high specificity ranging from 0.89 to 1.00 (95% confidence interval [CI]: 0.59-1.00); sensitivity varied from 0.38 to 0.97 (95% CI: 0.21-0.99). No studies were found that assessed the diagnostic accuracy of widely used neurological tests such as key muscle strength, tendon reflexes, and sensory impairments. There is limited evidence for accuracy of physical examination tests for the diagnosis of cervical radiculopathy. When consistent with patient history, clinicians may use a combination of Spurling's, axial traction, and an Arm Squeeze test to increase the likelihood of a cervical radiculopathy, whereas a combined results of four negative neurodynamics tests and an Arm Squeeze test could be used to rule out the disorder. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Towards improving diagnosis of memory loss in general practice: TIMeLi diagnostic test accuracy study protocol.

    PubMed

    Creavin, Sam T; Cullum, Sarah J; Haworth, Judy; Wye, Lesley; Bayer, Antony; Fish, Mark; Purdy, Sarah; Ben-Shlomo, Yoav

    2016-07-19

    People with cognitive problems, and their families, report distress and uncertainty whilst undergoing evaluation for dementia and perceive that traditional diagnostic evaluation in secondary care is insufficiently patient centred. The James Lind Alliance has prioritised research to investigate the role of primary care in supporting a more effective diagnostic pathway, and the topic is also of interest to health commissioners. However, there are very few studies that investigate the accuracy of diagnostic tests for dementia in primary care. We will conduct a prospective diagnostic test accuracy study to evaluate the accuracy of a range of simple tests for diagnosing all-cause-dementia in symptomatic people aged over 70 years who have consulted with their general practitioner (GP). We will invite eligible people to attend a research clinic where they will undergo a range of index tests that a GP could perform in the surgery and also be assessed by a specialist in memory disorders at the same appointment. Participating GPs will request neuroimaging and blood tests and otherwise manage patients in line with their usual clinical practice. The reference standard will be the consensus judgement of three experts (neurologist, psychiatrist and geriatrician) based on information from the specialist assessment, GP records and investigations, but not including items in the index test battery. The target condition will be all-cause dementia but we will also investigate diagnostic accuracy for sub-types where possible. We will use qualitative interviews with patients and focus groups with clinicians to help us understand the acceptability and feasibility of diagnosing dementia in primary care using the tests that we are investigating. Our results will help clinicians decide on which tests to perform in someone where there is concern about possible dementia and inform commissioning of diagnostic pathways.

  5. DIAGNOSTIC ACCURACY OF PHYSICAL EXAMINATION TESTS OF THE ANKLE/FOOT COMPLEX: A SYSTEMATIC REVIEW

    PubMed Central

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren

    2013-01-01

    Background: Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. Purpose: The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. Methods: A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Results: Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Conclusion: Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. Level of Evidence: 3a PMID:24175128

  6. A Systematic Review and Meta-analysis of the Diagnostic Accuracy of Prostate Health Index and 4-Kallikrein Panel Score in Predicting Overall and High-grade Prostate Cancer.

    PubMed

    Russo, Giorgio Ivan; Regis, Federica; Castelli, Tommaso; Favilla, Vincenzo; Privitera, Salvatore; Giardina, Raimondo; Cimino, Sebastiano; Morgia, Giuseppe

    2017-08-01

    Markers for prostate cancer (PCa) have progressed over recent years. In particular, the prostate health index (PHI) and the 4-kallikrein (4K) panel have been demonstrated to improve the diagnosis of PCa. We aimed to review the diagnostic accuracy of PHI and the 4K panel for PCa detection. We performed a systematic literature search of PubMed, EMBASE, Cochrane, and Academic One File databases until July 2016. We included diagnostic accuracy studies that used PHI or 4K panel for the diagnosis of PCa or high-grade PCa. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. Twenty-eight studies including 16,762 patients have been included for the analysis. The pooled data showed a sensitivity of 0.89 and 0.74 for PHI and 4K panel, respectively, for PCa detection and a pooled specificity of 0.34 and 0.60 for PHI and 4K panel, respectively. The derived area under the curve (AUC) from the hierarchical summary receiver operating characteristic (HSROC) showed an accuracy of 0.76 and 0.72 for PHI and 4K panel respectively. For high-grade PCa detection, the pooled sensitivity was 0.93 and 0.87 for PHI and 4K panel, respectively, whereas the pooled specificity was 0.34 and 0.61 for PHI and 4K panel, respectively. The derived AUC from the HSROC showed an accuracy of 0.82 and 0.81 for PHI and 4K panel, respectively. Both PHI and the 4K panel provided good diagnostic accuracy in detecting overall and high-grade PCa. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Ontario multidetector computed tomographic coronary angiography study: field evaluation of diagnostic accuracy.

    PubMed

    Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron

    2011-06-13

    Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.

  8. Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses.

    PubMed

    Lange, Berit; Cohn, Jennifer; Roberts, Teri; Camp, Johannes; Chauffour, Jeanne; Gummadi, Nina; Ishizaki, Azumi; Nagarathnam, Anupriya; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Easterbrook, Philippa; Denkinger, Claudia M

    2017-11-01

    Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.

  9. Comparison and validation of International Consensus Diagnostic Criteria for diagnosis of autoimmune pancreatitis from pancreatic cancer in a Taiwanese cohort.

    PubMed

    Chang, Ming-Chu; Liang, Po-Chin; Jan, I-Shiow; Yang, Ching-Yao; Tien, Yu-Wen; Wei, Shu-Chen; Wong, Jau-Min; Chang, Yu-Ting

    2014-08-18

    The International Consensus Diagnostic Criteria (ICDC) designed to diagnosis autoimmune pancreatitis (AIP) has been proposed recently. The diagnostic performance of ICDC has not been previously evaluated in diffuse-type and focal-type AIP, respectively, in comparison with the revised HISORt and Asian criteria in Taiwan. Prospective, consecutive patient cohort. Largest tertiary referred centre hospital managing pancreatic disease in Taiwan. 188 patients with AIP and 130 with tissue proofed pancreatic adenocarcinoma were consecutively recruited. The ICDC, as well as revised HISORt and Asian criteria, was applied for each participant. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in diffuse-type and focal-type AIP. Sensitivity, specificity and accuracy. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in AIP and focal-type AIP. The sensitivity, specificity and accuracy of ICDC for all AIP were the best: 89.4%, 100% and 93.7%, respectively, in these three criteria. The sensitivity, specificity and accuracy of ICDC for focal-type AIP (84.9%, 100% and 93.8%) were also the best among these three criteria. The area under the curve of receiver-operator characteristic of ICDC was 0.95 (95% CI 0.92 to 0.97) in all AIP and 0.93 (95% CI 0.88 to 0.97) in focal-type AIP. The sensitivity, specificity and accuracy of ICDC are higher than the revised HISORt and Asian criteria. The sensitivity, specificity and accuracy of each criterion are higher in diffuse-type AIP compared with focal-type AIP. Under the same specificity, the sensitivity and accuracy of ICDC are higher than other diagnostic criteria in focal-type AIP. ICDC has better diagnostic performance compared with previously proposed diagnostic criteria in diffuse-type and focal-type AIP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Diagnostic relevance of high field MRI in clinical neuroradiology: the advantages and challenges of driving a sports car.

    PubMed

    Wattjes, Mike P; Barkhof, Frederik

    2012-11-01

    High field MRI operating at 3 T is increasingly being used in the field of neuroradiology on the grounds that higher magnetic field strength should theoretically lead to a higher diagnostic accuracy in the diagnosis of several disease entities. This Editorial discusses the exhaustive review by Wardlaw and colleagues of research comparing 3 T MRI with 1.5 T MRI in the field of neuroradiology. Interestingly, the authors found no convincing evidence of improved image quality, diagnostic accuracy, or reduced total examination times using 3 T MRI instead of 1.5 T MRI. These findings are highly relevant since a new generation of high field MRI systems operating at 7 T has recently been introduced. • Higher magnetic field strengths do not necessarily lead to a better diagnostic accuracy. • Disadvantages of high field MR systems have to be considered in clinical practice. • Higher field strengths are needed for functional imaging, spectroscopy, etc. • Disappointingly there are few direct comparisons of 1.5 and 3 T MRI. • Whether the next high field MR generation (7 T) will improve diagnostic accuracy has to be investigated.

  11. Joint confidence region estimation for area under ROC curve and Youden index.

    PubMed

    Yin, Jingjing; Tian, Lili

    2014-03-15

    In the field of diagnostic studies, the area under the ROC curve (AUC) serves as an overall measure of a biomarker/diagnostic test's accuracy. Youden index, defined as the overall correct classification rate minus one at the optimal cut-off point, is another popular index. For continuous biomarkers of binary disease status, although researchers mainly evaluate the diagnostic accuracy using AUC, for the purpose of making diagnosis, Youden index provides an important and direct measure of the diagnostic accuracy at the optimal threshold and hence should be taken into consideration in addition to AUC. Furthermore, AUC and Youden index are generally correlated. In this paper, we initiate the idea of evaluating diagnostic accuracy based on AUC and Youden index simultaneously. As the first step toward this direction, this paper only focuses on the confidence region estimation of AUC and Youden index for a single marker. We present both parametric and non-parametric approaches for estimating joint confidence region of AUC and Youden index. We carry out extensive simulation study to evaluate the performance of the proposed methods. In the end, we apply the proposed methods to a real data set. Copyright © 2013 John Wiley & Sons, Ltd.

  12. Intelligent Diagnostic Assistant for Complicated Skin Diseases through C5's Algorithm.

    PubMed

    Jeddi, Fatemeh Rangraz; Arabfard, Masoud; Kermany, Zahra Arab

    2017-09-01

    Intelligent Diagnostic Assistant can be used for complicated diagnosis of skin diseases, which are among the most common causes of disability. The aim of this study was to design and implement a computerized intelligent diagnostic assistant for complicated skin diseases through C5's Algorithm. An applied-developmental study was done in 2015. Knowledge base was developed based on interviews with dermatologists through questionnaires and checklists. Knowledge representation was obtained from the train data in the database using Excel Microsoft Office. Clementine Software and C5's Algorithms were applied to draw the decision tree. Analysis of test accuracy was performed based on rules extracted using inference chains. The rules extracted from the decision tree were entered into the CLIPS programming environment and the intelligent diagnostic assistant was designed then. The rules were defined using forward chaining inference technique and were entered into Clips programming environment as RULE. The accuracy and error rates obtained in the training phase from the decision tree were 99.56% and 0.44%, respectively. The accuracy of the decision tree was 98% and the error was 2% in the test phase. Intelligent diagnostic assistant can be used as a reliable system with high accuracy, sensitivity, specificity, and agreement.

  13. An Alternate Method to Springback Compensation for Sheet Metal Forming

    PubMed Central

    Omar, Badrul; Jusoff, Kamaruzaman

    2014-01-01

    The aim of this work is to improve the accuracy of cold stamping product by accommodating springback. This is a numerical approach to improve the accuracy of springback analysis and die compensation process combining the displacement adjustment (DA) method and the spring forward (SF) algorithm. This alternate hybrid method (HM) is conducted by firstly employing DA method followed by the SF method instead of either DA or SF method individually. The springback shape and the target part are used to optimize the die surfaces compensating springback. The hybrid method (HM) algorithm has been coded in Fortran and tested in two- and three-dimensional models. By implementing the HM, the springback error can be decreased and the dimensional deviation falls in the predefined tolerance range. PMID:25165738

  14. [Risk on bias assessment: (6) A Revised Tool for the Quality Assessment on Diagnostic Accuracy Studies (QUADAS-2)].

    PubMed

    Qu, Y J; Yang, Z R; Sun, F; Zhan, S Y

    2018-04-10

    This paper introduced the Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2), including the development and comparison with the original QUADAS, and illustrated the application of QUADAS-2 in a published paper related to the study on diagnostic accuracy which was included in systematic review and Meta-analysis. QUADAS-2 presented considerable improvement over the original tool. Confused items that included in QUADAS had disappeared and the quality assessment of the original study replaced by the rating of risk on bias and applicability. This was implemented through the description on the four main domains with minimal overlapping and answering the signal questions in each domain. The risk of bias and applicability with 'high','low' or 'unclear' was in line with the risk of bias assessment of intervention studies in Cochrane, so to replace the total score of quality assessment in QUADAS. Meanwhile, QUADAS-2 was also applicable to assess the diagnostic accuracy studies in which follow-up without prognosis was involved in golden standard. It was useful to assess the overall methodological quality of the study despite more time consuming than the original QUADAS. However, QUADAS-2 needs to be modified to apply in comparative studies on diagnostic accuracy and we hope the users would follow the updates and give their feedbacks on line.

  15. Diagnostic accuracy of rectal mucosa biopsy testing for chronic wasting disease within white-tailed deer (Odocoileus virginianus) herds in North America:Effects of age,sex,polymorphism at PRNP codon 96,and disease progression

    USDA-ARS?s Scientific Manuscript database

    An effective live animal diagnostic test is needed to assist in the control of chronic wasting disease (CWD), which has spread through captive and wild herds of white-tailed deer (Odocoileus virginianus) in Canada and the United States. In the present study, the diagnostic accuracy of rectal mucosa ...

  16. Verification and classification bias interactions in diagnostic test accuracy studies for fine-needle aspiration biopsy.

    PubMed

    Schmidt, Robert L; Walker, Brandon S; Cohen, Michael B

    2015-03-01

    Reliable estimates of accuracy are important for any diagnostic test. Diagnostic accuracy studies are subject to unique sources of bias. Verification bias and classification bias are 2 sources of bias that commonly occur in diagnostic accuracy studies. Statistical methods are available to estimate the impact of these sources of bias when they occur alone. The impact of interactions when these types of bias occur together has not been investigated. We developed mathematical relationships to show the combined effect of verification bias and classification bias. A wide range of case scenarios were generated to assess the impact of bias components and interactions on total bias. Interactions between verification bias and classification bias caused overestimation of sensitivity and underestimation of specificity. Interactions had more effect on sensitivity than specificity. Sensitivity was overestimated by at least 7% in approximately 6% of the tested scenarios. Specificity was underestimated by at least 7% in less than 0.1% of the scenarios. Interactions between verification bias and classification bias create distortions in accuracy estimates that are greater than would be predicted from each source of bias acting independently. © 2014 American Cancer Society.

  17. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments.

    PubMed

    Shinkins, Bethany; Yang, Yaling; Abel, Lucy; Fanshawe, Thomas R

    2017-04-14

    Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1) what evidence aside from test accuracy was searched for and synthesised, 2) which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3) how/whether threshold effects were explored, 4) how the potential dependency between multiple tests in a pathway was accounted for, and 5) for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings. The uptake of appropriate meta-analysis methods for synthesising evidence on diagnostic test accuracy in UK NIHR HTAs has improved in recent years. Future research should focus on other evidence requirements for cost-effectiveness assessment, threshold effects for quantitative tests and the impact of multiple diagnostic tests.

  18. A novel antibody-based biomarker for chronic algal toxin exposure and sub-acute neurotoxicity

    USGS Publications Warehouse

    Lefebvre, Kathi A.; Frame, Elizabeth R.; Gulland, Frances; Hansen, John D.; Kendrick, Preston S.; Beyer, Richard P.; Bammler, Theo K.; Farin, Frederico M.; Hiolski, Emma M.; Smith, Donald R.; Marcinek, David J.

    2012-01-01

    The neurotoxic amino acid, domoic acid (DA), is naturally produced by marine phytoplankton and presents a significant threat to the health of marine mammals, seabirds and humans via transfer of the toxin through the foodweb. In humans, acute exposure causes a neurotoxic illness known as amnesic shellfish poisoning characterized by seizures, memory loss, coma and death. Regular monitoring for high DA levels in edible shellfish tissues has been effective in protecting human consumers from acute DA exposure. However, chronic low-level DA exposure remains a concern, particularly in coastal and tribal communities that subsistence harvest shellfish known to contain low levels of the toxin. Domoic acid exposure via consumption of planktivorous fish also has a profound health impact on California sea lions (Zalophus californianus) affecting hundreds of animals yearly. Due to increasing algal toxin exposure threats globally, there is a critical need for reliable diagnostic tests for assessing chronic DA exposure in humans and wildlife. Here we report the discovery of a novel DA-specific antibody response that is a signature of chronic low-level exposure identified initially in a zebrafish exposure model and confirmed in naturally exposed wild sea lions. Additionally, we found that chronic exposure in zebrafish caused increased neurologic sensitivity to DA, revealing that repetitive exposure to DA well below the threshold for acute behavioral toxicity has underlying neurotoxic consequences. The discovery that chronic exposure to low levels of a small, water-soluble single amino acid triggers a detectable antibody response is surprising and has profound implications for the development of diagnostic tests for exposure to other pervasive environmental toxins.

  19. A novel antibody-based biomarker for chronic algal toxin exposure and sub-acute neurotoxicity.

    PubMed

    Lefebvre, Kathi A; Frame, Elizabeth R; Gulland, Frances; Hansen, John D; Kendrick, Preston S; Beyer, Richard P; Bammler, Theo K; Farin, Frederico M; Hiolski, Emma M; Smith, Donald R; Marcinek, David J

    2012-01-01

    The neurotoxic amino acid, domoic acid (DA), is naturally produced by marine phytoplankton and presents a significant threat to the health of marine mammals, seabirds and humans via transfer of the toxin through the foodweb. In humans, acute exposure causes a neurotoxic illness known as amnesic shellfish poisoning characterized by seizures, memory loss, coma and death. Regular monitoring for high DA levels in edible shellfish tissues has been effective in protecting human consumers from acute DA exposure. However, chronic low-level DA exposure remains a concern, particularly in coastal and tribal communities that subsistence harvest shellfish known to contain low levels of the toxin. Domoic acid exposure via consumption of planktivorous fish also has a profound health impact on California sea lions (Zalophus californianus) affecting hundreds of animals yearly. Due to increasing algal toxin exposure threats globally, there is a critical need for reliable diagnostic tests for assessing chronic DA exposure in humans and wildlife. Here we report the discovery of a novel DA-specific antibody response that is a signature of chronic low-level exposure identified initially in a zebrafish exposure model and confirmed in naturally exposed wild sea lions. Additionally, we found that chronic exposure in zebrafish caused increased neurologic sensitivity to DA, revealing that repetitive exposure to DA well below the threshold for acute behavioral toxicity has underlying neurotoxic consequences. The discovery that chronic exposure to low levels of a small, water-soluble single amino acid triggers a detectable antibody response is surprising and has profound implications for the development of diagnostic tests for exposure to other pervasive environmental toxins.

  20. Is there any evidence for the validity of diagnostic criteria used for accommodative and nonstrabismic binocular dysfunctions?

    PubMed

    Cacho-Martínez, Pilar; García-Muñoz, Ángel; Ruiz-Cantero, María Teresa

    2014-01-01

    To analyze the diagnostic criteria used in the scientific literature published in the past 25 years for accommodative and nonstrabismic binocular dysfunctions and to explore if the epidemiological analysis of diagnostic validity has been used to propose which clinical criteria should be used for diagnostic purposes. We carried out a systematic review of papers on accommodative and non-strabic binocular disorders published from 1986 to 2012 analysing the MEDLINE, CINAHL, PsycINFO and FRANCIS databases. We admitted original articles about diagnosis of these anomalies in any population. We identified 839 articles and 12 studies were included. The quality of included articles was assessed using the QUADAS-2 tool. The review shows a wide range of clinical signs and cut-off points between authors. Only 3 studies (regarding accommodative anomalies) assessed diagnostic accuracy of clinical signs. Their results suggest using the accommodative amplitude and monocular accommodative facility for diagnosing accommodative insufficiency and a high positive relative accommodation for accommodative excess. The remaining 9 articles did not analyze diagnostic accuracy, assessing a diagnosis with the criteria the authors considered. We also found differences between studies in the way of considering patients' symptomatology. 3 studies of 12 analyzed, performed a validation of a symptom survey used for convergence insufficiency. Scientific literature reveals differences between authors according to diagnostic criteria for accommodative and nonstrabismic binocular dysfunctions. Diagnostic accuracy studies show that there is only certain evidence for accommodative conditions. For binocular anomalies there is only evidence about a validated questionnaire for convergence insufficiency with no data of diagnostic accuracy. Copyright © 2012 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  1. Systematic review of dermoscopy and digital dermoscopy/ artificial intelligence for the diagnosis of melanoma.

    PubMed

    Rajpara, S M; Botello, A P; Townend, J; Ormerod, A D

    2009-09-01

    Dermoscopy improves diagnostic accuracy of the unaided eye for melanoma, and digital dermoscopy with artificial intelligence or computer diagnosis has also been shown useful for the diagnosis of melanoma. At present there is no clear evidence regarding the diagnostic accuracy of dermoscopy compared with artificial intelligence. To evaluate the diagnostic accuracy of dermoscopy and digital dermoscopy/artificial intelligence for melanoma diagnosis and to compare the diagnostic accuracy of the different dermoscopic algorithms with each other and with digital dermoscopy/artificial intelligence for the detection of melanoma. A literature search on dermoscopy and digital dermoscopy/artificial intelligence for melanoma diagnosis was performed using several databases. Titles and abstracts of the retrieved articles were screened using a literature evaluation form. A quality assessment form was developed to assess the quality of the included studies. Heterogeneity among the studies was assessed. Pooled data were analysed using meta-analytical methods and comparisons between different algorithms were performed. Of 765 articles retrieved, 30 studies were eligible for meta-analysis. Pooled sensitivity for artificial intelligence was slightly higher than for dermoscopy (91% vs. 88%; P = 0.076). Pooled specificity for dermoscopy was significantly better than artificial intelligence (86% vs. 79%; P < 0.001). Pooled diagnostic odds ratio was 51.5 for dermoscopy and 57.8 for artificial intelligence, which were not significantly different (P = 0.783). There were no significance differences in diagnostic odds ratio among the different dermoscopic diagnostic algorithms. Dermoscopy and artificial intelligence performed equally well for diagnosis of melanocytic skin lesions. There was no significant difference in the diagnostic performance of various dermoscopy algorithms. The three-point checklist, the seven-point checklist and Menzies score had better diagnostic odds ratios than the others; however, these results need to be confirmed by a large-scale high-quality population-based study.

  2. Identification of facilitators and barriers to residents' use of a clinical reasoning tool.

    PubMed

    DiNardo, Deborah; Tilstra, Sarah; McNeil, Melissa; Follansbee, William; Zimmer, Shanta; Farris, Coreen; Barnato, Amber E

    2018-03-28

    While there is some experimental evidence to support the use of cognitive forcing strategies to reduce diagnostic error in residents, the potential usability of such strategies in the clinical setting has not been explored. We sought to test the effect of a clinical reasoning tool on diagnostic accuracy and to obtain feedback on its usability and acceptability. We conducted a randomized behavioral experiment testing the effect of this tool on diagnostic accuracy on written cases among post-graduate 3 (PGY-3) residents at a single internal medical residency program in 2014. Residents completed written clinical cases in a proctored setting with and without prompts to use the tool. The tool encouraged reflection on concordant and discordant aspects of each case. We used random effects regression to assess the effect of the tool on diagnostic accuracy of the independent case sets, controlling for case complexity. We then conducted audiotaped structured focus group debriefing sessions and reviewed the tapes for facilitators and barriers to use of the tool. Of 51 eligible PGY-3 residents, 34 (67%) participated in the study. The average diagnostic accuracy increased from 52% to 60% with the tool, a difference that just met the test for statistical significance in adjusted analyses (p=0.05). Residents reported that the tool was generally acceptable and understandable but did not recognize its utility for use with simple cases, suggesting the presence of overconfidence bias. A clinical reasoning tool improved residents' diagnostic accuracy on written cases. Overconfidence bias is a potential barrier to its use in the clinical setting.

  3. Diagnostic accuracy of optical coherence tomography in actinic keratosis and basal cell carcinoma.

    PubMed

    Olsen, J; Themstrup, L; De Carvalho, N; Mogensen, M; Pellacani, G; Jemec, G B E

    2016-12-01

    Early diagnosis of non-melanoma skin cancer (NMSC) is potentially possible using optical coherence tomography (OCT) which provides non-invasive, real-time images of skin with micrometre resolution and an imaging depth of up to 2mm. OCT technology for skin imaging has undergone significant developments, improving image quality substantially. The diagnostic accuracy of any method is influenced by continuous technological development making it necessary to regularly re-evaluate methods. The objective of this study is to estimate the diagnostic accuracy of OCT in basal cell carcinomas (BCC) and actinic keratosis (AK) as well as differentiating these lesions from normal skin. A study set consisting of 142 OCT images meeting selection criterea for image quality and diagnosis of AK, BCC and normal skin was presented uniformly to two groups of blinded observers: 5 dermatologists experienced in OCT-image interpretation and 5 dermatologists with no experience in OCT. During the presentation of the study set the observers filled out a standardized questionnaire regarding the OCT diagnosis. Images were captured using a commercially available OCT machine (Vivosight ® , Michelson Diagnostics, UK). Skilled OCT observers were able to diagnose BCC lesions with a sensitivity of 86% to 95% and a specificity of 81% to 98%. Skilled observers with at least one year of OCT-experience showed an overall higher diagnostic accuracy compared to inexperienced observers. The study shows an improved diagnostic accuracy of OCT in differentiating AK and BCC from healthy skin using state-of-the-art technology compared to earlier OCT technology, especially concerning BCC diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Efficacy and cost-effectiveness of stereotactic vacuum-assisted core biopsy of nonpalpable breast lesions: analysis of 602 biopsies performed over 5 years.

    PubMed

    Luparia, A; Durando, M; Campanino, P; Regini, E; Lucarelli, D; Talenti, A; Mattone, G; Mariscotti, G; Sapino, A; Gandini, G

    2011-04-01

    The authors sought to evaluate the diagnostic accuracy and cost-effectiveness of vacuum-assisted core biopsy (VACB) in comparison with diagnostic surgical excision for characterisation of nonpalpable breast lesions classified as Breast Imaging Reporting and Data System (BI-RADS) categories R3 and R4. From January 2004 to December 2008, we conducted 602 stereotactic, 11-gauge, VACB procedures on 243 nonpalpable breast lesions categorised as BI-RADS R3, 346 categorised as BI-RADS R4 and 13 categorised as BI-RADS R5. We calculated the diagnostic accuracy and cost savings of VACB by subtracting the cost of the stereotactic biopsy from that of the diagnostic surgical procedure. A total of 56% of the lesions were benign and required no further assessment. Lesions of uncertain malignant potential (B3) (23.6%) were debated at multidisciplinary meetings, and diagnostic surgical biopsy was recommended for 83.1% of them. All malignant lesions (B4 and B5) underwent surgical excision. VACB had a sensitivity of 94.9%, specificity of 98.3% and diagnostic accuracy of 97.7%. The cost savings per VACB procedure were 464.00 euro; by obviating 335 surgical biopsies, the overall cost savings was 155,440.00 euro over 5 years. VACB proved to have high diagnostic accuracy for characterising abnormalities at low to intermediate risk of malignancy and obviated surgical excision in about half of the cases, allowing for considerable cost savings.

  5. Clinical Validation of the "Sedentary Lifestyle" Nursing Diagnosis in Secondary School Students

    ERIC Educational Resources Information Center

    de Oliveira, Marcos Renato; da Silva, Viviane Martins; Guedes, Nirla Gomes; de Oliveira Lopes, Marcos Venícios

    2016-01-01

    This study clinically validated the nursing diagnosis of "sedentary lifestyle" (SL) among 564 Brazilian adolescents. Measures of diagnostic accuracy were calculated for defining characteristics, and Mantel--Haenszel analysis was used to identify related factors. The measures of diagnostic accuracy showed that the following defining…

  6. Effects of Experience and Training on Diagnostic Accuracy.

    ERIC Educational Resources Information Center

    Brammer, Robert

    The interview process was studied to uncover the relationship of expertise in psychotherapy to the likelihood of accurate diagnosis. Experience and training affect the number of diagnostic questions clinicians ask as compared to personal, family, social, occupational, and history questions; and this in turn affects the accuracy of the diagnoses…

  7. [Diagnostic performance of biliary ultrasound vs. magnetic resonance cholangiogram in patients with recurrent biliary obstruction.].

    PubMed

    Chávez-Valencia, V; Espinosa-Ortega, H F; Espinoza-Peralta, D; Arce-Salinas, C A

    2009-01-01

    Obstructive jaundice in patients with previous cholecystectomy requires a precise diagnosis. In the diagnostic algorithm, biliary ultrasound (BUS) and magnetic resonance cholangiogram (MRC) are used, although the accuracy of each method is unknown in our setting. No previous comparison of US and MRC in subjects with cholecystectomy has been made. To determine diagnostic accuracy of BUS and MRC in patients with recurrent biliary obstruction. Patients with endoscopic retrograde cholangiopacreatography (ERCP) demonstrating recurrent biliary obstruction by stones were included. All patients underwent BUS and MRC. We determined the diagnostic performance of each image study compared with ERCP. Twenty-seven patients with a mean age of 62.9 +/- 17.3 years-old were included. Sensitivity and specificity of BUS were 0.12 and 0.58, respectively. Figures for MRC were 0.88 and 0.82. Diagnostic agreement between ERCP and MRC was k= 0.66 whereas BUS had a k of only 0.26. MRC had good diagnostic performance for recurrent choledocolithiasis. BUS demonstrated lower accuracy compared with previous reports, so should not be considered in the initial approach of recurrent choledocus obstruction.

  8. Diagnostic accuracy of HLA-B*57:01 screening for the prediction of abacavir hypersensitivity and clinical utility of the test: a meta-analytic review.

    PubMed

    Cargnin, Sarah; Jommi, Claudio; Canonico, Pier Luigi; Genazzani, Armando A; Terrazzino, Salvatore

    2014-05-01

    To determine diagnostic accuracy of HLA-B*57:01 testing for prediction of abacavir-induced hypersensitivity and to quantify the clinical benefit of pretreatment screening through a meta-analytic review of published studies. A comprehensive search was performed up to June 2013. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. The pooled diagnostic estimates were calculated using a random effect model. Despite the presence of heterogeneity in sensitivity or specificity estimates, the pooled diagnostic odds ratio to detect abacavir-induced hypersensitivity on the basis of clinical criteria was 33.07 (95% CI: 22.33-48.97, I(2): 13.9%), while diagnostic odds ratio for detection of immunologically confirmed abacavir hypersensitivity was 1141 (95% CI: 409-3181, I(2): 0%). Pooled analysis of risk ratio showed that prospective HLA-B*57:01 testing significantly reduced the incidence of abacavir-induced hypersensitivity. This meta-analysis demonstrates an excellent diagnostic accuracy of HLA-B*57:01 testing to detect immunologically confirmed abacavir hypersensitivity and corroborates existing recommendations.

  9. Comparing diagnostic tests on benefit-risk.

    PubMed

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  10. Early-Onset Neonatal Sepsis: Still Room for Improvement in Procalcitonin Diagnostic Accuracy Studies

    PubMed Central

    Chiesa, Claudio; Pacifico, Lucia; Osborn, John F.; Bonci, Enea; Hofer, Nora; Resch, Bernhard

    2015-01-01

    Abstract To perform a systematic review assessing accuracy and completeness of diagnostic studies of procalcitonin (PCT) for early-onset neonatal sepsis (EONS) using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. EONS, diagnosed during the first 3 days of life, remains a common and serious problem. Increased PCT is a potentially useful diagnostic marker of EONS, but reports in the literature are contradictory. There are several possible explanations for the divergent results including the quality of studies reporting the clinical usefulness of PCT in ruling in or ruling out EONS. We systematically reviewed PubMed, Scopus, and the Cochrane Library databases up to October 1, 2014. Studies were eligible for inclusion in our review if they provided measures of PCT accuracy for diagnosing EONS. A data extraction form based on the STARD checklist and adapted for neonates with EONS was used to appraise the quality of the reporting of included studies. We found 18 articles (1998–2014) fulfilling our eligibility criteria which were included in the final analysis. Overall, the results of our analysis showed that the quality of studies reporting diagnostic accuracy of PCT for EONS was suboptimal leaving ample room for improvement. Information on key elements of design, analysis, and interpretation of test accuracy were frequently missing. Authors should be aware of the STARD criteria before starting a study in this field. We welcome stricter adherence to this guideline. Well-reported studies with appropriate designs will provide more reliable information to guide decisions on the use and interpretations of PCT test results in the management of neonates with EONS. PMID:26222858

  11. The Generalized Anxiety Disorder Screener (GAD-7) and the anxiety module of the Hospital and Depression Scale (HADS-A) as screening tools for generalized anxiety disorder among cancer patients.

    PubMed

    Esser, Peter; Hartung, Tim J; Friedrich, Michael; Johansen, Christoffer; Wittchen, Hans-Ulrich; Faller, Hermann; Koch, Uwe; Härter, Martin; Keller, Monika; Schulz, Holger; Wegscheider, Karl; Weis, Joachim; Mehnert, Anja

    2018-06-01

    Anxiety in cancer patients may represent a normal psychological reaction. To detect patients with pathological levels, appropriate screeners with established cut-offs are needed. Given that previous research is sparse, we investigated the diagnostic accuracy of 2 frequently used screening tools in detecting generalized anxiety disorder (GAD). We used data of a multicenter study including 2141 cancer patients. Diagnostic accuracy was investigated for the Generalized Anxiety Disorder Screener (GAD-7) and the anxiety module of the Hospital Anxiety and Depression Scale (HADS-A). GAD, assessed with the Composite International Diagnostic Interview for Oncology, served as a reference standard. Overall accuracy was measured with the area under the receiver operating characteristics curve (AUC). The AUC of the 2 screeners were statistically compared. We also calculated accuracy measures for selected cut-offs. Diagnostic accuracy could be interpreted as adequate for both screeners, with an identical AUC of .81 (95% CI: .79-.82). Consequently, the 2 screeners did not differ in their performance (P = .86). The best balance between sensitivity and specificity was found for cut-offs ≥7 (GAD-7) and ≥8 (HADS-A). The officially recommended thresholds for the GAD-7 (≥ 10) and the HADS-A (≥11) showed low sensitivities of 55% and 48%, respectively. The GAD-7 and HADS-A showed AUC of adequate diagnostic accuracy and hence are applicable for GAD screening in cancer patients. Nevertheless, the choice of optimal cut-offs should be carefully evaluated. Copyright © 2018 John Wiley & Sons, Ltd.

  12. Men's interpretations of graphical information in a videotape decision aid 1

    PubMed Central

    Pylar, Jan; Wills, Celia E.; Lillie, Janet; Rovner, David R.; Kelly‐Blake, Karen; Holmes‐Rovner, Margaret

    2007-01-01

    Abstract Objective  To examine men's interpretations of graphical information types viewed in a high‐quality, previously tested videotape decision aid (DA). Setting, participants, design  A community‐dwelling sample of men >50 years of age (N = 188) balanced by education (college/non‐college) and race (Black/White) were interviewed just following their viewing of a videotape DA. A descriptive study design was used to examine men's interpretations of a representative sample of the types of graphs that were shown in the benign prostatic hyperplasia videotape DA. Main variables studied  Men provided their interpretation of graphs information presented in three formats that varied in complexity: pictograph, line and horizontal bar graph. Audiotape transcripts of men's responses were coded for meaning and content‐related interpretation statements. Results  Men provided both meaning and content‐focused interpretations of the graphs. Accuracy of interpretation was lower than hypothesized on the basis of literature review (85.4% for pictograph, 65.7% for line graph, 47.8% for horizontal bar graph). Accuracy for pictograph and line graphs was associated with education level,  = 3.94, P = 0.047, and  = 7.55, P = 0.006, respectively. Accuracy was uncorrelated with men's reported liking of the graphs,  = 2.00, P = 0.441. Conclusion  While men generally liked the DA, accuracy of graphs interpretation was associated with format complexity and education level. Graphs are often recommended to improve comprehension of information in DAs. However, additional evaluation is needed in experimental and naturalistic observational settings to develop best practice standards for data representation. PMID:17524011

  13. The Effects of Q-Matrix Design on Classification Accuracy in the Log-Linear Cognitive Diagnosis Model.

    PubMed

    Madison, Matthew J; Bradshaw, Laine P

    2015-06-01

    Diagnostic classification models are psychometric models that aim to classify examinees according to their mastery or non-mastery of specified latent characteristics. These models are well-suited for providing diagnostic feedback on educational assessments because of their practical efficiency and increased reliability when compared with other multidimensional measurement models. A priori specifications of which latent characteristics or attributes are measured by each item are a core element of the diagnostic assessment design. This item-attribute alignment, expressed in a Q-matrix, precedes and supports any inference resulting from the application of the diagnostic classification model. This study investigates the effects of Q-matrix design on classification accuracy for the log-linear cognitive diagnosis model. Results indicate that classification accuracy, reliability, and convergence rates improve when the Q-matrix contains isolated information from each measured attribute.

  14. NMR-based metabolomic urinalysis: a rapid screening test for urinary tract infection.

    PubMed

    Lam, Ching-Wan; Law, Chun-Yiu; To, Kelvin Kai-Wang; Cheung, Stanley Kwok-Kuen; Lee, Kim-Chung; Sze, Kong-Hung; Leung, Ka-Fai; Yuen, Kwok-Yung

    2014-09-25

    Urinary tract infection (UTI) is one of the most common bacterial infections in humans; however, there is no accurate and fast quantitative test to detect UTI. Dipstick urinalysis is semi-quantitative with a limited diagnostic accuracy, while urine culture is accurate but takes time. We described a quantitative biochemical method for the diagnosis of bacteriuria using a single marker. We compared the urine metabolomes from 88 patients with bacterial UTI and 61 controls using (1)H NMR spectroscopy followed by principal component analysis (PCA) and orthogonal partial least squares-discriminant analysis (OPLS-DA). The biomarker identified was subsequently validated using independent samples. The urine acetic acid/creatinine (mmol/mmol) level was determined to be the most discriminatory marker for bacterial UTI with an area-under-receiver operating characteristic curve=0.97, sensitivity=91% and specificity=95% at the optimal cutoff 0.03 mmol/mmol. For validation, 60 samples were recruited prospectively. Using the optimal cutoff for acetic acid/creatinine, this method showed sensitivity=96%, specificity=94%, positive predictive value=92%, negative predictive value=97% and an overall accuracy=95%. The diagnostic performance was superior to dipstick urinalysis or microscopy. In addition, we also observed an increase of urinary trimethylamine (TMA) in patients with Escherichia coli-associated UTI. TMA is a mammalian-microbial co-metabolite and the high level of TMA generated is related to the bacterial enzyme, trimethylamine N-oxide (TMAO) reductase which reduces TMAO to TMA. Urine acetic acid is a neglected metabolite that can be used for rapid diagnosis of UTI and TMA can be used for etiologic diagnosis of UTI. With the introduction of NMR-based clinical analyzers to clinical laboratories, NMR-based urinalysis can be translated for clinical use. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Diagnostic Accuracy of Global Pharma Health Fund Minilab™ in Assessing Pharmacopoeial Quality of Antimicrobials.

    PubMed

    Pan, Hui; Ba-Thein, William

    2018-01-01

    Global Pharma Health Fund (GPHF) Minilab™, a semi-quantitative thin-layer chromatography (TLC)-based commercially available test kit, is widely used in drug quality surveillance globally, but its diagnostic accuracy is unclear. We investigated the diagnostic accuracy of Minilab system for antimicrobials, using high-performance liquid chromatography (HPLC) as reference standard. Following the Minilab protocols and the Pharmacopoeia of the People's Republic of China protocols, Minilab-TLC and HPLC were used to test five common antimicrobials (506 batches) for relative concentration of active pharmaceutical ingredients. The prevalence of poor-quality antimicrobials determined, respectively, by Minilab TLC and HPLC was amoxicillin (0% versus 14.9%), azithromycin (0% versus 17.4%), cefuroxime axetil (14.3% versus 0%), levofloxacin (0% versus 3.0%), and metronidazole (0% versus 38.0%). The Minilab TLC had false-positive and false-negative detection rates of 2.6% (13/506) and 15.2% (77/506) accordingly, resulting in the following test characteristics: sensitivity 0%, specificity 97.0%, positive predictive value 0, negative predictive value 0.8, positive likelihood ratio 0, negative likelihood ratio 1.0, diagnostic odds ratio 0, and adjusted diagnostic odds ratio 0.2. This study demonstrates unsatisfying diagnostic accuracy of Minilab system in screening poor-quality antimicrobials of common use. Using Minilab as a stand-alone system for monitoring drug quality should be reconsidered.

  16. Comparison of Diagnostic Accuracy of Clinical Measures of Breast Cancer–Related Lymphedema: Area Under the Curve

    PubMed Central

    Smoot, Betty J.; Wong, Josephine F.; Dodd, Marylin J.

    2013-01-01

    Objective To compare diagnostic accuracy of measures of breast cancer–related lymphedema (BCRL). Design Cross-sectional design comparing clinical measures with the criterion standard of previous diagnosis of BCRL. Setting University of California San Francisco Translational Science Clinical Research Center. Participants Women older than 18 years and more than 6 months posttreatment for breast cancer (n=141; 70 with BCRL, 71 without BCRL). Interventions Not applicable. Main Outcome Measures Sensitivity, specificity, receiver operator characteristic curve, and area under the curve (AUC) were used to evaluate accuracy. Results A total of 141 women were categorized as having (n=70) or not having (n=71) BCRL based on past diagnosis by a health care provider, which was used as the reference standard. Analyses of ROC curves for the continuous outcomes yielded AUC of .68 to .88 (P<.001); of the physical measures bioimpedance spectroscopy yielded the highest accuracy with an AUC of .88 (95% confidence interval, .80–.96) for women whose dominant arm was the affected arm. The lowest accuracy was found using the 2-cm diagnostic cutoff score to identify previously diagnosed BCRL (AUC, .54–.65). Conclusions Our findings support the use of bioimpedance spectroscopy in the assessment of existing BCRL. Refining diagnostic cutoff values may improve accuracy of diagnosis and warrant further investigation. PMID:21440706

  17. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis

    PubMed Central

    2015-01-01

    Background Obscure gastrointestinal bleeding (OGIB) is defined as persistent or recurrent bleeding associated with negative findings on upper and lower gastrointestinal (GI) endoscopic evaluations. The diagnosis and management of patients with OGIB is particularly challenging because of the length and complex loops of the small intestine. Capsule endoscopy (CE) is 1 diagnostic modality that is used to determine the etiology of bleeding. Objectives The objective of this analysis was to review the diagnostic accuracy, safety, and impact on health outcomes of CE in patients with OGIB in comparison with other diagnostic modalities. Data Sources A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2007 and 2013. Review Methods Data on diagnostic accuracy, safety, and impact on health outcomes were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results The search yielded 1,189 citations, and 24 studies were included. Eight studies reported diagnostic accuracy comparing CE with other diagnostic modalities. Capsule endoscopy has a higher sensitivity and lower specificity than magnetic resonance enteroclysis, computed tomography, and push enteroscopy. Capsule endoscopy has a good safety profile with few adverse events, although comparative safety data with other diagnostic modalities are limited. Capsule endoscopy is associated with no difference in patient health-related outcomes such as rebleeding or follow-up treatment compared with push enteroscopy, small-bowel follow-through, and angiography. Limitations There was significant heterogeneity in estimates of diagnostic accuracy, which prohibited a statistical summary of findings. The analysis was also limited by the fact that there is no established reference standard to which the diagnostic accuracy of CE can be compared. Conclusions There is very-low-quality evidence that CE has a higher sensitivity but a lower specificity than other diagnostic modalities. Capsule endoscopy has few adverse events, with capsule retention being the most serious complication. Capsule endoscopy is perceived by patients as less painful and less burdensome compared with other modalities. There is low-quality evidence that patients who undergo CE have similar rates of rebleeding, further therapeutic interventions, and hospitalization compared with other diagnostic modalities. PMID:26357529

  18. A metabolic fingerprinting approach based on selected ion flow tube mass spectrometry (SIFT-MS) and chemometrics: A reliable tool for Mediterranean origin-labeled olive oils authentication.

    PubMed

    Bajoub, Aadil; Medina-Rodríguez, Santiago; Ajal, El Amine; Cuadros-Rodríguez, Luis; Monasterio, Romina Paula; Vercammen, Joeri; Fernández-Gutiérrez, Alberto; Carrasco-Pancorbo, Alegría

    2018-04-01

    Selected Ion flow tube mass spectrometry (SIFT-MS) in combination with chemometrics was used to authenticate the geographical origin of Mediterranean virgin olive oils (VOOs) produced under geographical origin labels. In particular, 130 oil samples from six different Mediterranean regions (Kalamata (Greece); Toscana (Italy); Meknès and Tyout (Morocco); and Priego de Córdoba and Baena (Spain)) were considered. The headspace volatile fingerprints were measured by SIFT-MS in full scan with H 3 O + , NO + and O 2 + as precursor ions and the results were subjected to chemometric treatments. Principal Component Analysis (PCA) was used for preliminary multivariate data analysis and Partial Least Squares-Discriminant Analysis (PLS-DA) was applied to build different models (considering the three reagent ions) to classify samples according to the country of origin and regions (within the same country). The multi-class PLS-DA models showed very good performance in terms of fitting accuracy (98.90-100%) and prediction accuracy (96.70-100% accuracy for cross validation and 97.30-100% accuracy for external validation (test set)). Considering the two-class PLS-DA models, the one for the Spanish samples showed 100% sensitivity, specificity and accuracy in calibration, cross validation and external validation; the model for Moroccan oils also showed very satisfactory results (with perfect scores for almost every parameter in all the cases). Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Considerations Underlying the Use of Mixed Group Validation

    ERIC Educational Resources Information Center

    Jewsbury, Paul A.; Bowden, Stephen C.

    2013-01-01

    Mixed Group Validation (MGV) is an approach for estimating the diagnostic accuracy of tests. MGV is a promising alternative to the more commonly used Known Groups Validation (KGV) approach for estimating diagnostic accuracy. The advantage of MGV lies in the fact that the approach does not require a perfect external validity criterion or gold…

  20. The diagnostic accuracy of Clinical Dehydration Scale in identifying dehydration in children with acute gastroenteritis: a systematic review.

    PubMed

    Falszewska, Anna; Dziechciarz, Piotr; Szajewska, Hania

    2014-10-01

    To systematically update diagnostic accuracy of the Clinical Dehydration Scale (CDS) in clinical recognition of dehydration in children with acute gastroenteritis. Six databases were searched for diagnostic accuracy studies in which population were children aged 1 to 36 months with acute gastroenteritis; index test was the CDS; and reference test was post-illness weight gain. Three studies involving 360 children were included. Limited evidence showed that in high-income countries the CDS provides strong diagnostic accuracy for ruling in moderate and severe (>6%) dehydration (positive likelihood ratio 5.2-6.6), but has limited value for ruling it out (negative likelihood ratio 0.4-0.55). In low-income countries, the CDS has limited value either for ruling moderate or severe dehydration in or out. In both settings, the CDS had limited value for ruling in or out dehydration <3% or dehydration 3% to 6%. The CDS can help assess moderate to severe dehydration in high-income settings. Given the limited data, the evidence should be viewed with caution. © The Author(s) 2014.

  1. Adjusting for partial verification or workup bias in meta-analyses of diagnostic accuracy studies.

    PubMed

    de Groot, Joris A H; Dendukuri, Nandini; Janssen, Kristel J M; Reitsma, Johannes B; Brophy, James; Joseph, Lawrence; Bossuyt, Patrick M M; Moons, Karel G M

    2012-04-15

    A key requirement in the design of diagnostic accuracy studies is that all study participants receive both the test under evaluation and the reference standard test. For a variety of practical and ethical reasons, sometimes only a proportion of patients receive the reference standard, which can bias the accuracy estimates. Numerous methods have been described for correcting this partial verification bias or workup bias in individual studies. In this article, the authors describe a Bayesian method for obtaining adjusted results from a diagnostic meta-analysis when partial verification or workup bias is present in a subset of the primary studies. The method corrects for verification bias without having to exclude primary studies with verification bias, thus preserving the main advantages of a meta-analysis: increased precision and better generalizability. The results of this method are compared with the existing methods for dealing with verification bias in diagnostic meta-analyses. For illustration, the authors use empirical data from a systematic review of studies of the accuracy of the immunohistochemistry test for diagnosis of human epidermal growth factor receptor 2 status in breast cancer patients.

  2. Reported estimates of diagnostic accuracy in ophthalmology conference abstracts were not associated with full-text publication

    PubMed Central

    Korevaar, Daniël A.; Cohen, Jérémie F.; Spijker, René; Saldanha, Ian J.; Dickersin, Kay; Virgili, Gianni; Hooft, Lotty; Bossuyt, Patrick M.M.

    2016-01-01

    Objective To assess whether conference abstracts that report higher estimates of diagnostic accuracy are more likely to reach full-text publication in a peer-reviewed journal. Study Design and Setting We identified abstracts describing diagnostic accuracy studies, presented between 2007 and 2010 at the Association for Research in Vision and Ophthalmology (ARVO) Annual Meeting. We extracted reported estimates of sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and diagnostic odds ratio (DOR). Between May and July 2015, we searched MEDLINE and EMBASE to identify corresponding full-text publications; if needed, we contacted abstract authors. Cox regression was performed to estimate associations with full-text publication, where sensitivity, specificity, and AUC were logit transformed, and DOR was log transformed. Results A full-text publication was found for 226/399 (57%) included abstracts. There was no association between reported estimates of sensitivity and full-text publication (hazard ratio [HR] 1.09 [95% confidence interval {CI} 0.98, 1.22]). The same applied to specificity (HR 1.00 [95% CI 0.88, 1.14]), AUC (HR 0.91 [95% CI 0.75, 1.09]), and DOR (HR 1.01 [95% CI 0.94, 1.09]). Conclusion Almost half of the ARVO conference abstracts describing diagnostic accuracy studies did not reach full-text publication. Studies in abstracts that mentioned higher accuracy estimates were not more likely to be reported in a full-text publication. PMID:27312228

  3. Imaging markers for Alzheimer disease

    PubMed Central

    Bocchetta, Martina; Chételat, Gael; Rabinovici, Gil D.; de Leon, Mony J.; Kaye, Jeffrey; Reiman, Eric M.; Scheltens, Philip; Barkhof, Frederik; Black, Sandra E.; Brooks, David J.; Carrillo, Maria C.; Fox, Nick C.; Herholz, Karl; Nordberg, Agneta; Jack, Clifford R.; Jagust, William J.; Johnson, Keith A.; Rowe, Christopher C.; Sperling, Reisa A.; Thies, William; Wahlund, Lars-Olof; Weiner, Michael W.; Pasqualetti, Patrizio; DeCarli, Charles

    2013-01-01

    Revised diagnostic criteria for Alzheimer disease (AD) acknowledge a key role of imaging biomarkers for early diagnosis. Diagnostic accuracy depends on which marker (i.e., amyloid imaging, 18F-fluorodeoxyglucose [FDG]-PET, SPECT, MRI) as well as how it is measured (“metric”: visual, manual, semiautomated, or automated segmentation/computation). We evaluated diagnostic accuracy of marker vs metric in separating AD from healthy and prognostic accuracy to predict progression in mild cognitive impairment. The outcome measure was positive (negative) likelihood ratio, LR+ (LR−), defined as the ratio between the probability of positive (negative) test outcome in patients and the probability of positive (negative) test outcome in healthy controls. Diagnostic LR+ of markers was between 4.4 and 9.4 and LR− between 0.25 and 0.08, whereas prognostic LR+ and LR− were between 1.7 and 7.5, and 0.50 and 0.11, respectively. Within metrics, LRs varied up to 100-fold: LR+ from approximately 1 to 100; LR− from approximately 1.00 to 0.01. Markers accounted for 11% and 18% of diagnostic and prognostic variance of LR+ and 16% and 24% of LR−. Across all markers, metrics accounted for an equal or larger amount of variance than markers: 13% and 62% of diagnostic and prognostic variance of LR+, and 29% and 18% of LR−. Within markers, the largest proportion of diagnostic LR+ and LR− variability was within 18F-FDG-PET and MRI metrics, respectively. Diagnostic and prognostic accuracy of imaging AD biomarkers is at least as dependent on how the biomarker is measured as on the biomarker itself. Standard operating procedures are key to biomarker use in the clinical routine and drug trials. PMID:23897875

  4. An index with improved diagnostic accuracy for the diagnosis of Crohn's disease derived from the Lennard-Jones criteria.

    PubMed

    Reinisch, S; Schweiger, K; Pablik, E; Collet-Fenetrier, B; Peyrin-Biroulet, L; Alfaro, I; Panés, J; Moayyedi, P; Reinisch, W

    2016-09-01

    The Lennard-Jones criteria are considered the gold standard for diagnosing Crohn's disease (CD) and include the items granuloma, macroscopic discontinuity, transmural inflammation, fibrosis, lymphoid aggregates and discontinuous inflammation on histology. The criteria have never been subjected to a formal validation process. To develop a validated and improved diagnostic index based on the items of Lennard-Jones criteria. Included were 328 adult patients with long-standing CD (median disease duration 10 years) from three centres and classified as 'established', 'probable' or 'non-CD' by Lennard-Jones criteria at time of diagnosis. Controls were patients with ulcerative colitis (n = 170). The performance of each of the six diagnostic items of Lennard-Jones criteria was modelled by logistic regression and a new index based on stepwise backward selection and cut-offs was developed. The diagnostic value of the new index was analysed by comparing sensitivity, specificity and accuracy vs. Lennard-Jones criteria. By Lennard-Jones criteria 49% (n = 162) of CD patients would have been diagnosed as 'non-CD' at time of diagnosis (sensitivity/specificity/accuracy, 'established' CD: 0.34/0.99/0.67; 'probable' CD: 0.51/0.95/0.73). A new index was derived from granuloma, fibrosis, transmural inflammation and macroscopic discontinuity, but excluded lymphoid aggregates and discontinuous inflammation on histology. Our index provided improved diagnostic accuracy for 'established' and 'probable' CD (sensitivity/specificity/accuracy, 'established' CD: 0.45/1/0.72; 'probable' CD: 0.8/0.85/0.82), including the subgroup isolated colonic CD ('probable' CD, new index: 0.73/0.85/0.79; Lennard-Jones criteria: 0.43/0.95/0.69). We developed an index based on items of Lennard-Jones criteria providing improved diagnostic accuracy for the differential diagnosis between CD and UC. © 2016 John Wiley & Sons Ltd.

  5. Diagnostic Accuracy of Fall Risk Assessment Tools in People With Diabetic Peripheral Neuropathy

    PubMed Central

    Pohl, Patricia S.; Mahnken, Jonathan D.; Kluding, Patricia M.

    2012-01-01

    Background Diabetic peripheral neuropathy affects nearly half of individuals with diabetes and leads to increased fall risk. Evidence addressing fall risk assessment for these individuals is lacking. Objective The purpose of this study was to identify which of 4 functional mobility fall risk assessment tools best discriminates, in people with diabetic peripheral neuropathy, between recurrent “fallers” and those who are not recurrent fallers. Design A cross-sectional study was conducted. Setting The study was conducted in a medical research university setting. Participants The participants were a convenience sample of 36 individuals between 40 and 65 years of age with diabetic peripheral neuropathy. Measurements Fall history was assessed retrospectively and was the criterion standard. Fall risk was assessed using the Functional Reach Test, the Timed “Up & Go” Test, the Berg Balance Scale, and the Dynamic Gait Index. Sensitivity, specificity, positive and negative likelihood ratios, and overall diagnostic accuracy were calculated for each fall risk assessment tool. Receiver operating characteristic curves were used to estimate modified cutoff scores for each fall risk assessment tool; indexes then were recalculated. Results Ten of the 36 participants were classified as recurrent fallers. When traditional cutoff scores were used, the Dynamic Gait Index and Functional Reach Test demonstrated the highest sensitivity at only 30%; the Dynamic Gait Index also demonstrated the highest overall diagnostic accuracy. When modified cutoff scores were used, all tools demonstrated improved sensitivity (80% or 90%). Overall diagnostic accuracy improved for all tests except the Functional Reach Test; the Timed “Up & Go” Test demonstrated the highest diagnostic accuracy at 88.9%. Limitations The small sample size and retrospective fall history assessment were limitations of the study. Conclusions Modified cutoff scores improved diagnostic accuracy for 3 of 4 fall risk assessment tools when testing people with diabetic peripheral neuropathy. PMID:22836004

  6. Pooled diagnostic accuracy of resting distal to aortic coronary pressure referenced to fractional flow reserve: The importance of resting coronary physiology.

    PubMed

    Maini, Rohit; Moscona, John; Sidhu, Gursukhman; Katigbak, Paul; Fernandez, Camilo; Irimpen, Anand; Mogabgab, Owen; Ward, Charisse; Samson, Rohan; LeJemtel, Thierry

    2018-04-29

    Both resting and hyperemic physiologic methods to guide coronary revascularization improve cardiovascular outcomes compared with angiographic guidance alone. Fractional flow reserve (FFR) remains underutilized due to concerns regarding hyperemia, prompting study of resting distal to aortic coronary pressure (Pd/Pa). Pd/Pa is a vasodilator-free resting index unlike FFR. While Pd/Pa is similar to another resting index, instantaneous wave-free ratio (iFR), it is a whole-cycle measurement not limited to the wave-free diastolic period. Pd/Pa is not validated clinically although multiple accuracy studies have been performed. Our meta-analysis examines the overall diagnostic accuracy of Pd/Pa referenced to FFR, the accepted invasive standard of ischemia. We searched PubMed, EMBASE, Central, ProQuest, and Web of Science databases for full text articles published through August 9, 2017 addressing the diagnostic accuracy of Pd/Pa referenced to FFR < 0.80. The following keywords were used: "distal coronary artery pressure" OR "Pd/Pa" AND "fractional flow reserve" OR "FFR." In total, 14 studies comprising 7004 lesions were identified. Pooled diagnostic accuracy estimates of Pd/Pa versus FFR < 0.80 were: sensitivity, 0.77 (95% CI, 0.75-0.78); specificity, 0.82 (0.81-0.83); positive likelihood ratio, 4.7 (3.3-6.6); negative likelihood ratio, 0.29 (0.24-0.34); diagnostic odds ratio, 18.1 (14.4-22.6); area under the summary receiver-operating characteristic curve of 0.88; and diagnostic accuracy of 0.80 (0.76-0.83). Pd/Pa shows adequate agreement with FFR as a resting index of coronary stenosis severity without the undesired effects and cost of hyperemic agents. Pd/Pa has the potential to guide coronary revascularization with easier application and availability compared with iFR and FFR. © 2018, Wiley Periodicals, Inc.

  7. Diagnostic Accuracy of Obstructive Airway Adult Test for Diagnosis of Obstructive Sleep Apnea.

    PubMed

    Gasparini, Giulio; Vicini, Claudio; De Benedetto, Michele; Salamanca, Fabrizio; Sorrenti, Giovanni; Romandini, Mario; Bosi, Marcello; Saponaro, Gianmarco; Foresta, Enrico; Laforì, Andreina; Meccariello, Giuseppe; Bianchi, Alessandro; Toraldo, Domenico Maurizio; Campanini, Aldo; Montevecchi, Filippo; Rizzotto, Grazia; Cervelli, Daniele; Moro, Alessandro; Arigliani, Michele; Gobbi, Riccardo; Pelo, Sandro

    2015-01-01

    The gold standard for the diagnosis of Obstructive Sleep Apnea (OSA) is polysomnography, whose access is however reduced by costs and limited availability, so that additional diagnostic tests are needed. To analyze the diagnostic accuracy of the Obstructive Airway Adult Test (OAAT) compared to polysomnography for the diagnosis of OSA in adult patients. Ninety patients affected by OSA verified with polysomnography (AHI ≥ 5) and ten healthy patients, randomly selected, were included and all were interviewed by one blind examiner with OAAT questions. The Spearman rho, evaluated to measure the correlation between OAAT and polysomnography, was 0.72 (p < 0.01). The area under the ROC curve (95% CI) was the parameter to evaluate the accuracy of the OAAT: it was 0.91 (0.81-1.00) for the diagnosis of OSA (AHI ≥ 5), 0.90 (0.82-0.98) for moderate OSA (AHI ≥ 15), and 0.84 (0.76-0.92) for severe OSA (AHI ≥ 30). The OAAT has shown a high correlation with polysomnography and also a high diagnostic accuracy for the diagnosis of OSA. It has also been shown to be able to discriminate among the different degrees of severity of OSA. Additional large studies aiming to validate this questionnaire as a screening or diagnostic test are needed.

  8. The value of rapid on-site evaluation during EBUS-TBNA.

    PubMed

    Cardoso, A V; Neves, I; Magalhães, A; Sucena, M; Barroca, H; Fernandes, G

    2015-01-01

    Rapid on-site evaluation (ROSE) has the potential to increase endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) accuracy in the diagnosis of mediastinal lesions and lung cancer staging. However, studies have reported controversial results. The purpose of our study was to evaluate the influence of ROSE on sample adequacy and diagnostic accuracy of EBUS-TBNA. Prospective observational study that enrolled 81 patients who underwent EBUS-TBNA for investigation of hilo-mediastinal lesions or lung cancer staging. The first 41 patients underwent EBUS-TBNA with ROSE (ROSE group) and the last 40 patients without ROSE (non-ROSE group). Sample adequacy and diagnostic accuracy of EBUS-TBNA in both groups were compared. Adequate samples were obtained in 93% of the patients in the ROSE group and 80% in non-ROSE group (p=0.10). The diagnostic accuracy of EBUS-TBNA was 91% in ROSE group and 83% in non-ROSE group (p=0.08). Analyzing the EBUS-TBNA purpose, in the subgroup of patients who underwent EBUS-TBNA for investigation of hilo-mediastinal lesions, these differences between ROSE and non-ROSE group were higher compared to lung cancer staging, 93% of patients with adequate samples in the ROSE group vs. 75% in the non-ROSE group (p=0.06) and 87% of diagnostic accuracy in ROSE group vs. 77% in non-ROSE group (p=0.10). Despite the lack of statistical significance, ROSE appears to be particularly useful in the diagnostic work-up of hilo-mediastinal lesions, increasing the diagnostic yield of EBUS-TBNA. Copyright © 2014 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L.U. All rights reserved.

  9. Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.

    PubMed

    Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo

    2017-01-01

    To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the  14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.

  10. Allergen extracts and recombinant proteins: comparison of efficiency of in vitro allergy diagnostics using multiplex assay on a biological microchip.

    PubMed

    Smoldovskaya, Olga; Feyzkhanova, Guzel; Arefieva, Alla; Voloshin, Sergei; Ivashkina, Olga; Reznikov, Yuriy; Rubina, Alla

    2016-01-01

    Immunological test systems for diagnostics of type I hypersensitivity involve the following types of antigens: whole allergen extracts, individual highly purified proteins and their recombinant analogues. The goal of this study was to compare the results obtained with whole allergen extracts (birch pollen, cat dander, and timothy grass pollen) and their respective recombinant proteins in biochip-based immunoassay. Multiplex fluorescent immunoassay of 139 patients' blood serum samples was carried out using biological microchips (biochips). sIgE concentrations for the chosen allergens and their recombinant components were measured. ROC analysis was used for comparison of the results and determination of diagnostic accuracy. The results for the birch pollen extract and its recombinant allergens have shown that the diagnostic accuracy of the methods utilizing the whole allergen extract, its major component Bet v 1 and the combination of major and minor components (Bet v 1 and Bet v 2) was the same. Values for diagnostic accuracy for the cat dander extract and its major recombinant component Fel d 1 were equal. In contrast with birch pollen and cat dander allergens, using of recombinant components of timothy grass pollen (Phl p 1, Phl p 5, Phl p 7 and Phl p 12) did not allow reaching the diagnostic accuracy of using natural extract. Multiplex analysis of samples obtained from patients with allergy to birch pollen and cat dander using biological microchips has shown that comparable accuracy was observed for the assay with natural extracts and recombinant allergens. In the case of timothy grass allergen, using the recombinant components may be insufficient.

  11. The Development of Expertise in Radiology: In Chest Radiograph Interpretation, "Expert" Search Pattern May Predate "Expert" Levels of Diagnostic Accuracy for Pneumothorax Identification.

    PubMed

    Kelly, Brendan S; Rainford, Louise A; Darcy, Sarah P; Kavanagh, Eoin C; Toomey, Rachel J

    2016-07-01

    Purpose To investigate the development of chest radiograph interpretation skill through medical training by measuring both diagnostic accuracy and eye movements during visual search. Materials and Methods An institutional exemption from full ethical review was granted for the study. Five consultant radiologists were deemed the reference expert group, and four radiology registrars, five senior house officers (SHOs), and six interns formed four clinician groups. Participants were shown 30 chest radiographs, 14 of which had a pneumothorax, and were asked to give their level of confidence as to whether a pneumothorax was present. Receiver operating characteristic (ROC) curve analysis was carried out on diagnostic decisions. Eye movements were recorded with a Tobii TX300 (Tobii Technology, Stockholm, Sweden) eye tracker. Four eye-tracking metrics were analyzed. Variables were compared to identify any differences between groups. All data were compared by using the Friedman nonparametric method. Results The average area under the ROC curve for the groups increased with experience (0.947 for consultants, 0.792 for registrars, 0.693 for SHOs, and 0.659 for interns; P = .009). A significant difference in diagnostic accuracy was found between consultants and registrars (P = .046). All four eye-tracking metrics decreased with experience, and there were significant differences between registrars and SHOs. Total reading time decreased with experience; it was significantly lower for registrars compared with SHOs (P = .046) and for SHOs compared with interns (P = .025). Conclusion Chest radiograph interpretation skill increased with experience, both in terms of diagnostic accuracy and visual search. The observed level of experience at which there was a significant difference was higher for diagnostic accuracy than for eye-tracking metrics. (©) RSNA, 2016 Online supplemental material is available for this article.

  12. Competency-based assessment in surgeon-performed head and neck ultrasonography: A validity study.

    PubMed

    Todsen, Tobias; Melchiors, Jacob; Charabi, Birgitte; Henriksen, Birthe; Ringsted, Charlotte; Konge, Lars; von Buchwald, Christian

    2018-06-01

    Head and neck ultrasonography (HNUS) increasingly is used as a point-of-care diagnostic tool by otolaryngologists. However, ultrasonography (US) is a very operator-dependent image modality. Hence, this study aimed to explore the diagnostic accuracy of surgeon-performed HNUS and to establish validity evidence for an objective structured assessment of ultrasound skills (OSAUS) used for competency-based assessment. A prospective experimental study. Six otolaryngologists and 11 US novices were included in a standardized test setup for which they had to perform focused HNUS of eight patients suspected for different head and neck lesions. Their diagnostic accuracy was calculated based on the US reports, and two blinded raters assessed the video-recorded US performance using the OSAUS scale. The otolaryngologists obtained a high diagnostic accuracy on 88% (range 63%-100%) compared to the US novices on 38% (range 0-63%); P < 0.001. The OSAUS score demonstrated good inter-case reliability (0.85) and inter-rater reliability (0.76), and significant discrimination between otolaryngologist and US novices; P < 0.001. A strong correlation between the OSAUS score and the diagnostic accuracy was found (Spearman's ρ, 0.85; P < P 0.001), and a pass/fail score was established at 2.8. Strong validity evidence supported the use of the OSAUS scale to assess HNUS competence with good reliability, significant discrimination between US competence levels, and a strong correlation of assessment score to diagnostic accuracy. An OSAUS pass/fail score was established and could be used for competence-based assessment in surgeon-performed HNUS. NA. Laryngoscope, 128:1346-1352, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  13. Methods specification for diagnostic test accuracy studies in fine-needle aspiration cytology: a survey of reporting practice.

    PubMed

    Schmidt, Robert L; Factor, Rachel E; Affolter, Kajsa E; Cook, Joshua B; Hall, Brian J; Narra, Krishna K; Witt, Benjamin L; Wilson, Andrew R; Layfield, Lester J

    2012-01-01

    Diagnostic test accuracy (DTA) studies on fine-needle aspiration cytology (FNAC) often show considerable variability in diagnostic accuracy between study centers. Many factors affect the accuracy of FNAC. A complete description of the testing parameters would help make valid comparisons between studies and determine causes of performance variation. We investigated the manner in which test conditions are specified in FNAC DTA studies to determine which parameters are most commonly specified and the frequency with which they are specified and to see whether there is significant variability in reporting practice. We identified 17 frequently reported test parameters and found significant variation in the reporting of these test specifications across studies. On average, studies reported 5 of the 17 items that would be required to specify the test conditions completely. A more complete and standardized reporting of methods, perhaps by means of a checklist, would improve the interpretation of FNAC DTA studies.

  14. Indexing of diagnosis accuracy studies in MEDLINE and EMBASE.

    PubMed

    Wilczynski, Nancy L; Haynes, R Brian

    2007-10-11

    STAndards for Reporting of Diagnostic Accuracy (STARD) were published in 2003 and endorsed by some journals but not others. To determine whether the quality of indexing of diagnostic accuracy studies in MEDLINE and EMBASE has improved since the STARD statement was published. Evaluate the change in the mean number of "accurate index terms" assigned to diagnostic accuracy studies, comparing STARD (endorsing) and non-STARD (non-endorsing) journals, for 2 years before and after STARD publication. In MEDLINE, no differences in indexing quality were found for STARD and non-STARD journals before or after the STARD statement was published in 2003. In EMBASE, indexing in STARD journals improved compared with non-STARD journals (p = 0.02). However, articles in STARD journals had half the number of accurate indexing terms as articles in non-STARD journals, both before and after STARD statement publication (p < 0.001).

  15. Diagnostic accuracy of language sample measures with Persian-speaking preschool children.

    PubMed

    Kazemi, Yalda; Klee, Thomas; Stringer, Helen

    2015-04-01

    This study examined the diagnostic accuracy of selected language sample measures (LSMs) with Persian-speaking children. A pre-accuracy study followed by phase I and II studies are reported. Twenty-four Persian-speaking children, aged 42 to 54 months, with primary language impairment (PLI) were compared to 27 age-matched children without PLI on a set of measures derived from play-based, conversational language samples. Results showed that correlations between age and LSMs were not statistically significant in either group of children. However, a majority of LSMs differentiated children with and without PLI at the group level (phase I), while three of the measures exhibited good diagnostic accuracy at the level of the individual (phase II). We conclude that general LSMs are promising for distinguishing between children with and without PLI. Persian-specific measures are mainly helpful in identifying children without language impairment while their ability to identify children with PLI is poor.

  16. Diagnostic Accuracy of Coronary Computed Tomography Before Aortic Valve Replacement: Systematic Review and Meta-Analysis.

    PubMed

    Chaikriangkrai, Kongkiat; Jhun, Hye Yeon; Shantha, Ghanshyam Palamaner Subash; Abdulhak, Aref Bin; Tandon, Rudhir; Alqasrawi, Musab; Klappa, Anthony; Pancholy, Samir; Deshmukh, Abhishek; Bhama, Jay; Sigurdsson, Gardar

    2018-07-01

    In aortic stenosis patients referred for surgical and transcatheter aortic valve replacement (AVR), the evidence of diagnostic accuracy of coronary computed tomography angiography (CCTA) has been limited. The objective of this study was to investigate the diagnostic accuracy of CCTA for significant coronary artery disease (CAD) in patients referred for AVR using invasive coronary angiography (ICA) as the gold standard. We searched databases for all diagnostic studies of CCTA in patients referred for AVR, which reported diagnostic testing characteristics on patient-based analysis required to pool summary sensitivity, specificity, positive-likelihood ratio, and negative-likelihood ratio. Significant CAD in both CCTA and ICA was defined by >50% stenosis in any coronary artery, coronary stent, or bypass graft. Thirteen studies evaluated 1498 patients (mean age, 74 y; 47% men; 76% transcatheter AVR). The pooled prevalence of significant stenosis determined by ICA was 43%. Hierarchical summary receiver-operating characteristic analysis demonstrated a summary area under curve of 0.96. The pooled sensitivity, specificity, and positive-likelihood and negative-likelihood ratios of CCTA in identifying significant stenosis determined by ICA were 95%, 79%, 4.48, and 0.06, respectively. In subgroup analysis, the diagnostic profiles of CCTA were comparable between surgical and transcatheter AVR. Despite the higher prevalence of significant CAD in patients with aortic stenosis than with other valvular heart diseases, our meta-analysis has shown that CCTA has a suitable diagnostic accuracy profile as a gatekeeper test for ICA. Our study illustrates a need for further study of the potential role of CCTA in preoperative planning for AVR.

  17. Diagnostic Accuracy of Cerebrospinal Fluid Amyloid-β Isoforms for Early and Differential Dementia Diagnosis.

    PubMed

    Struyfs, Hanne; Van Broeck, Bianca; Timmers, Maarten; Fransen, Erik; Sleegers, Kristel; Van Broeckhoven, Christine; De Deyn, Peter P; Streffer, Johannes R; Mercken, Marc; Engelborghs, Sebastiaan

    2015-01-01

    Overlapping cerebrospinal fluid biomarkers (CSF) levels between Alzheimer's disease (AD) and non-AD patients decrease differential diagnostic accuracy of the AD core CSF biomarkers. Amyloid-β (Aβ) isoforms might improve the AD versus non-AD differential diagnosis. To determine the added diagnostic value of Aβ isoforms, Aβ(1-37), Aβ(1-38), and Aβ(1-40), as compared to the AD CSF biomarkers Aβ(1-42), T-tau, and P-tau(181P). CSF from patients with dementia due to AD (n = 50), non-AD dementias (n = 50), mild cognitive impairment due to AD (n = 50) and non-demented controls (n = 50) was analyzed with a prototype multiplex assay using MSD detection technology. The non-AD group consisted of frontotemporal dementia (FTD; n = 17), dementia with Lewy bodies (DLB; n = 17), and vascular dementia (n = 16). Aβ(1-37) and Aβ(1-38) increased accuracy to differentiate AD from FTD or DLB. Aβ(1-37), Aβ(1-38), and Aβ(1-40) levels correlated with Mini-Mental State Examination scores and disease duration in dementia due to AD. The Aβ(1-42)/Aβ(1-40) ratio improved diagnostic performance of Aβ(1-42) in most differential diagnostic situations. Aβ(1-42) levels were lower in APOE ε4 carriers compared to non-carriers. Aβ isoforms help to differentiate AD from FTD and DLB. Aβ isoforms increase diagnostic performance of Aβ(1-42). In contrast to Aβ1-42, Aβ isoforms seem to be correlated with disease severity in AD. Adding the Aβ isoforms to the current biomarker panel could enhance diagnostic accuracy.

  18. ROC curves in clinical chemistry: uses, misuses, and possible solutions.

    PubMed

    Obuchowski, Nancy A; Lieber, Michael L; Wians, Frank H

    2004-07-01

    ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas >/=0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.

  19. Get the Diagnosis: an evidence-based medicine collaborative Wiki for diagnostic test accuracy.

    PubMed

    Hammer, Mark M; Kohlberg, Gavriel D

    2017-04-01

    Despite widespread calls for its use, there are challenges to the implementation of evidence-based medicine (EBM) in clinical practice. In response to the challenges of finding timely, pertinent information on diagnostic test accuracy, we developed an online, crowd-sourced Wiki on diagnostic test accuracy called Get the Diagnosis (GTD, http://www.getthediagnosis.org). Since its launch in November 2008 till October 2015, GTD has accumulated information on 300 diagnoses, with 1617 total diagnostic entries. There are a total of 1097 unique diagnostic tests with a mean of 5.4 tests (range 0-38) per diagnosis. 73% of entries (1182 of 1617) have an associated sensitivity and specificity and 89% of entries (1432 of 1617) have associated peer-reviewed literature citations. Altogether, GTD contains 474 unique literature citations. For a sample of three diagnoses, the search precision (percentage of relevant results in the first 30 entries) in GTD was 100% as compared with a range of 13.3%-63.3% for PubMed and between 6.7% and 76.7% for Google Scholar. GTD offers a fast, precise and efficient way to look up diagnostic test accuracy. On three selected examples, GTD had a greater precision rate compared with PubMed and Google Scholar in identifying diagnostic test information. GTD is a free resource that complements other currently available resources. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  20. Usefulness of magnifying endoscopy with narrow-band imaging for diagnosis of depressed gastric lesions

    PubMed Central

    SUMIE, HIROAKI; SUMIE, SHUJI; NAKAHARA, KEITA; WATANABE, YASUTOMO; MATSUO, KEN; MUKASA, MICHITA; SAKAI, TAKESHI; YOSHIDA, HIKARU; TSURUTA, OSAMU; SATA, MICHIO

    2014-01-01

    The usefulness of magnifying endoscopy with narrow-band imaging (ME-NBI) for the diagnosis of early gastric cancer is well known, however, there are no evaluation criteria. The aim of this study was to devise and evaluate a novel diagnostic algorithm for ME-NBI in depressed early gastric cancer. Between August, 2007 and May, 2011, 90 patients with a total of 110 depressed gastric lesions were enrolled in the study. A diagnostic algorithm was devised based on ME-NBI microvascular findings: microvascular irregularity and abnormal microvascular patterns (fine network, corkscrew and unclassified patterns). The diagnostic efficiency of the algorithm for gastric cancer and histological grade was assessed by measuring its mean sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy. Furthermore, inter- and intra-observer variation were measured. In the differential diagnosis of gastric cancer from non-cancerous lesions, the mean sensitivity, specificity, PPV, NPV, and accuracy of the diagnostic algorithm were 86.7, 48.0, 94.4, 26.7, and 83.2%, respectively. Furthermore, in the differential diagnosis of undifferentiated adenocarcinoma from differentiated adenocarcinoma, the mean sensitivity, specificity, PPV, NPV, and accuracy of the diagnostic algorithm were 61.6, 86.3, 69.0, 84.8, and 79.1%, respectively. For the ME-NBI final diagnosis using this algorithm, the mean κ values for inter- and intra-observer agreement were 0.50 and 0.77, respectively. In conclusion, the diagnostic algorithm based on ME-NBI microvascular findings was convenient and had high diagnostic accuracy, reliability and reproducibility in the differential diagnosis of depressed gastric lesions. PMID:24649321

  1. ITER ECE Diagnostic: Design Progress of IN-DA and the diagnostic role for Physics

    NASA Astrophysics Data System (ADS)

    Pandya, H. K. B.; Kumar, Ravinder; Danani, S.; Shrishail, P.; Thomas, Sajal; Kumar, Vinay; Taylor, G.; Khodak, A.; Rowan, W. L.; Houshmandyar, S.; Udintsev, V. S.; Casal, N.; Walsh, M. J.

    2017-04-01

    The ECE Diagnostic system in ITER will be used for measuring the electron temperature profile evolution, electron temperature fluctuations, the runaway electron spectrum, and the radiated power in the electron cyclotron frequency range (70-1000 GHz), These measurements will be used for advanced real time plasma control (e.g. steering the electron cyclotron heating beams), and physics studies. The scope of the Indian Domestic Agency (IN-DA) is to design and develop the polarizer splitter units; the broadband (70 to 1000 GHz) transmission lines; a high temperature calibration source in the Diagnostics Hall; two Michelson Interferometers (70 to 1000 GHz) and a 122-230 GHz radiometer. The remainder of the ITER ECE diagnostic system is the responsibility of the US domestic agency and the ITER Organization (IO). The design needs to conform to the ITER Organization’s strict requirements for reliability, availability, maintainability and inspect-ability. Progress in the design and development of various subsystems and components considering various engineering challenges and solutions will be discussed in this paper. This paper will also highlight how various ECE measurements can enhance understanding of plasma physics in ITER.

  2. German translation, cross-cultural adaptation and diagnostic test accuracy of three frailty screening tools : PRISMA-7, FRAIL scale and Groningen Frailty Indicator.

    PubMed

    Braun, Tobias; Grüneberg, Christian; Thiel, Christian

    2018-04-01

    Routine screening for frailty could be used to timely identify older people with increased vulnerability und corresponding medical needs. The aim of this study was the translation and cross-cultural adaptation of the PRISMA-7 questionnaire, the FRAIL scale and the Groningen Frailty Indicator (GFI) into the German language as well as a preliminary analysis of the diagnostic test accuracy of these instruments used to screen for frailty. A diagnostic cross-sectional study was performed. The instrument translation into German followed a standardized process. Prefinal versions were clinically tested on older adults who gave structured in-depth feedback on the scales in order to compile a final revision of the German language scale versions. For the analysis of diagnostic test accuracy (criterion validity), PRISMA-7, FRAIL scale and GFI were considered the index tests. Two reference tests were applied to assess frailty, either based on Fried's model of a Physical Frailty Phenotype or on the model of deficit accumulation, expressed in a Frailty Index. Prefinal versions of the German translations of each instrument were produced and completed by 52 older participants (mean age: 73 ± 6 years). Some minor issues concerning comprehensibility and semantics of the scales were identified and resolved. Using the Physical Frailty Phenotype (frailty prevalence: 4%) criteria as a reference standard, the accuracy of the instruments was excellent (area under the curve AUC >0.90). Taking the Frailty Index (frailty prevalence: 23%) as the reference standard, the accuracy was good (AUC between 0.73 and 0.88). German language versions of PRISMA-7, FRAIL scale and GFI have been established and preliminary results indicate sufficient diagnostic test accuracy that needs to be further established.

  3. Purification and analyses of the specificity of two putative diagnostic antigens for larval cyathostomin infection in horses.

    PubMed

    Dowdall, S M J; Proudman, C J; Love, S; Klei, T R; Matthews, J B

    2003-12-01

    Cyathostomins are important equine gastrointestinal parasites. Mass emergence of mucosal stage larvae causes a potentially fatal colitis. Mucosal stages are undetectable non-invasively. An assay that would estimate mucosal larval stage infection would greatly assist in treatment, control and prognosis. Previously, we identified two putative diagnostic antigens (20 and 25 kDa) in somatic larval preparations. Here, we describe their purification and antigen-specific IgG(T) responses to them. Western blots confirmed the purity of the antigens and showed that epitopes in the 20 kDa complex were specific to larval cyathostomins. No cross-reactive antigens appeared to be present in Parascaris equorum or Strongyloides westeri species. Low levels of cross-reactivity were observed in Strongylus edentatus and Strongylus vulgaris species. Use of purified antigens greatly reduced background binding in equine sera. These results indicate that both antigen complexes may be of use in a diagnostic assay.

  4. Diagnostic accuracy of the Thessaly test, standardised clinical history and other clinical examination tests (Apley's, McMurray's and joint line tenderness) for meniscal tears in comparison with magnetic resonance imaging diagnosis.

    PubMed

    Blyth, Mark; Anthony, Iain; Francq, Bernard; Brooksbank, Katriona; Downie, Paul; Powell, Andrew; Jones, Bryn; MacLean, Angus; McConnachie, Alex; Norrie, John

    2015-08-01

    Reliable non-invasive diagnosis of meniscal tears is difficult. Magnetic resonance imaging (MRI) is often used but is expensive and incidental findings are problematic. There are a number of physical examination tests for the diagnosis of meniscal tears that are simple, cheap and non-invasive. To determine the diagnostic accuracy of the Thessaly test and to determine if the Thessaly test (alone or in combination with other physical tests) can obviate the need for further investigation by MRI or arthroscopy for patients with a suspected meniscal tear. Single-centre prospective diagnostic accuracy study. Although the study was performed in a secondary care setting, it was designed to replicate the results that would have been achieved in a primary care setting. Two cohorts of patients were recruited: patients with knee pathology (n = 292) and a control cohort with no knee pathology (n = 75). Sensitivity, specificity and diagnostic accuracy of the Thessaly test in determining the presence of meniscal tears. Participants were assessed by both a primary care clinician and a musculoskeletal clinician. Both clinicians performed the Thessaly test, McMurray's test, Apley's test, joint line tenderness test and took a standardised clinical history from the patient. The Thessaly test had a sensitivity of 0.66, a specificity of 0.39 and a diagnostic accuracy of 54% when utilised by primary care clinicians. This compared with a sensitivity of 0.62, a specificity of 0.55 and diagnostic accuracy of 59% when used by musculoskeletal clinicians. The diagnostics accuracy of the other tests when used by primary care clinicians was 54% for McMurray's test, 53% for Apley's test, 54% for the joint line tenderness test and 55% for clinical history. For primary care clinicians, age and past history of osteoarthritis were both significant predictors of MRI diagnosis of meniscal tears. For musculoskeletal clinicians age and a positive diagnosis of meniscal tears on clinical history taking were significant predictors of MRI diagnosis. No physical tests were significant predictors of MRI diagnosis in our multivariate models. The specificity of MRI diagnosis was tested in subgroup of patients who went on to have a knee arthroscopy and was found to be low [0.53 (95% confidence interval 0.28 to 0.77)], although the sensitivity was 1.0. The Thessaly test was no better at diagnosing meniscal tears than other established physical tests. The sensitivity, specificity and diagnostic accuracy of all physical tests was too low to be of routine clinical value as an alternative to MRI. Caution needs to be exercised in the indiscriminate use of MRI scanning in the identification of meniscal tears in the diagnosis of the painful knee, due to the low specificity seen in the presence of concomitant knee pathology. Further research is required to determine the true diagnostic accuracy and cost-effectiveness of MRI for the detection of meniscal tears. Current Controlled Trial ISRCTN43527822. The National Institute for Health Research Health Technology Assessment programme.

  5. Accuracy of clinical diagnosis of Parkinson disease: A systematic review and meta-analysis.

    PubMed

    Rizzo, Giovanni; Copetti, Massimiliano; Arcuti, Simona; Martino, Davide; Fontana, Andrea; Logroscino, Giancarlo

    2016-02-09

    To evaluate the diagnostic accuracy of clinical diagnosis of Parkinson disease (PD) reported in the last 25 years by a systematic review and meta-analysis. We searched for articles published between 1988 and August 2014. Studies were included if reporting diagnostic parameters regarding clinical diagnosis of PD or crude data. The selected studies were subclassified based on different study setting, type of test diagnosis, and gold standard. Bayesian meta-analyses of available data were performed. We selected 20 studies, including 11 using pathologic examination as gold standard. Considering only these 11 studies, the pooled diagnostic accuracy was 80.6% (95% credible interval [CrI] 75.2%-85.3%). Accuracy was 73.8% (95% CrI 67.8%-79.6%) for clinical diagnosis performed mainly by nonexperts. Accuracy of clinical diagnosis performed by movement disorders experts rose from 79.6% (95% CrI 46%-95.1%) of initial assessment to 83.9% (95% CrI 69.7%-92.6%) of refined diagnosis after follow-up. Using UK Parkinson's Disease Society Brain Bank Research Center criteria, the pooled diagnostic accuracy was 82.7% (95% CrI 62.6%-93%). The overall validity of clinical diagnosis of PD is not satisfying. The accuracy did not significantly improve in the last 25 years, particularly in the early stages of disease, where response to dopaminergic treatment is less defined and hallmarks of alternative diagnoses such as atypical parkinsonism may not have emerged. Misclassification rate should be considered to calculate the sample size both in observational studies and randomized controlled trials. Imaging and biomarkers are urgently needed to improve the accuracy of clinical diagnosis in vivo. © 2016 American Academy of Neurology.

  6. Diagnostic accuracy of mammography readers and their memory performance have no correlation with each other.

    PubMed

    Kok, P; Pitman, A G; Cawson, J N; Gledhill, S; Kremer, S; Lawson, J; Mehta, K; Mercuri, V; Shnier, D; Taft, R; Zentner, L

    2010-08-01

    The study aims to determine if any association exists between visual memory performance and diagnostic accuracy performance in a group of radiologist mammogram readers. One hundred proven mammograms (23 with cancers) were grouped into 5 sets of 20 cases, with sets being of equal difficulty. Pairs of sets were presented in 5 reads (40 cases per read, order random) to a panel of 8 radiologist readers (either present or past screening readers, with experience range from <1 year to >20 years). The readers were asked to either 'clear' or 'call back' cases depending on need for further workup, and at post-baseline reads to indicate whether each case was 'new' or 'old' (i.e. remembered from prior read). Two sets were presented only at baseline (40 cases per reader), and were used to calculate the reader's false recollection rate. Three sets were repeated post-baseline once or twice (100 cases per reader). Reading conditions were standardised. Memory performance differed markedly between readers. The number of correctly remembered cases (of 100 'old' cases) had a median of 10.5 and range of 0-58. The observed number of false recollections (of 40 'totally new' cases) had a median of 2 and range of 0-17. Diagnostic performance measures were mean (range): sensitivity 0.68 (0.54-0.81); specificity 0.82 (0.74-0.91); positive predictive value (PPV) 0.55 (0.50-0.65); negative predictive value (NPV) 0.89 (0.86-0.93) and accuracy 0.78 (0.76-0.83). Confidence intervals (CIs; 95%) for each reader overlapped for all the diagnostic parameters, indicating a lack of statistically significant difference between the readers at the 5% level. The most sensitive and the most specific reader showed a trend away from each other on sensitivity, specificity, NPV and PPV; their accuracies were 0.76 and 0.82, respectively, and their accuracy 95% CIs overlapped considerably. Correlation analysis by reader showed no association between observed memory performance and any of the diagnostic accuracy measures in our group of readers. In particular, there was no correlation between diagnostic accuracy and memory performance. There was no association between visual memory performance and diagnostic accuracy as a screening mammographer in our group of eight representative readers. Whether a radiologist has a good or a bad visual memory for cases, and in particular mammograms, should not impact on his or her performance as a radiologist and mammogram reader.

  7. Evaluating IRT- and CTT-Based Methods of Estimating Classification Consistency and Accuracy Indices from Single Administrations

    ERIC Educational Resources Information Center

    Deng, Nina

    2011-01-01

    Three decision consistency and accuracy (DC/DA) methods, the Livingston and Lewis (LL) method, LEE method, and the Hambleton and Han (HH) method, were evaluated. The purposes of the study were: (1) to evaluate the accuracy and robustness of these methods, especially when their assumptions were not well satisfied, (2) to investigate the "true"…

  8. Assessing the activity of perianal Crohn's disease: comparison of clinical indices and computer-assisted anal ultrasound.

    PubMed

    Losco, Alessandra; Viganò, Chiara; Conte, Dario; Cesana, Bruno Mario; Basilisco, Guido

    2009-05-01

    Assessing perianal disease activity is important for the treatment and prognosis of Crohn's disease (CD) patients, but the diagnostic accuracy of the activity indices has not yet been established. The aim of this study was to determine the accuracy and agreement of the Fistula Drainage Assessment (FDA), Perianal Disease Activity Index (PDAI), and computer-assisted anal ultrasound imaging (AUS). Sixty-two consecutive patients with CD and perianal fistulae underwent clinical, FDA, PDAI, and AUS evaluation. Perianal disease was considered active in the presence of visible fistula drainage and/or signs of local inflammation (induration and pain at digital compression) upon clinical examination. The AUS images were analyzed by calculating the mean gray-scale tone of the lesion. The PDAI and gray-scale tone values discriminating active and inactive perianal disease were defined using receiver operating characteristics statistics. Perianal disease was active in 46 patients. The accuracy of the FDA was 87% (confidence interval [CI]: 76%-94%). A PDAI of >4 and a mean gray-scale tone value of 117 maximized sensitivity and specificity; their diagnostic accuracy was, respectively, 87% (CI: 76%-94%) and 81% (CI: 69%-90%). The agreement of the 3 evaluations was fair to moderate. The addition of AUS to the PDAI or FDA increased their diagnostic accuracy to respectively 95% and 98%. The diagnostic accuracy of the FDA, PDAI, and computer-assisted AUS imaging was good in assessing perianal disease activity in patients with CD. The agreement between the techniques was fair to moderate. Overall accuracy can be increased by combining the FDA or PDAI with AUS.

  9. Adherence to Standards for Reporting Diagnostic Accuracy in Emergency Medicine Research.

    PubMed

    Gallo, Lucas; Hua, Nadia; Mercuri, Mathew; Silveira, Angela; Worster, Andrew

    2017-08-01

    Diagnostic tests are used frequently in the emergency department (ED) to guide clinical decision making and, hence, influence clinical outcomes. The Standards for Reporting of Diagnostic Accuracy (STARD) criteria were developed to ensure that diagnostic test studies are performed and reported to best inform clinical decision making in the ED. The objective was to determine the extent to which diagnostic studies published in emergency medicine journals adhered to STARD 2003 criteria. Diagnostic studies published in eight MEDLINE-listed, peer-reviewed, emergency medicine journals over a 5-year period were reviewed for compliance to STARD criteria. A total of 12,649 articles were screened and 114 studies were included in our study. Twenty percent of these were randomly selected for assessment using STARD 2003 criteria. Adherence to STARD 2003 reporting standards for each criteria ranged from 8.7% adherence (criteria-reporting adverse events from performing index test or reference standard) to 100% (multiple criteria). Just over half of STARD criteria are reported in more than 80% studies. As poorly reported studies may negatively impact their clinical usefulness, it is essential that studies of diagnostic test accuracy be performed and reported adequately. Future studies should assess whether studies have improved compliance with the STARD 2015 criteria amendment. © 2017 by the Society for Academic Emergency Medicine.

  10. Giant cell arteritis: diagnostic accuracy of MR imaging of superficial cranial arteries in initial diagnosis-results from a multicenter trial.

    PubMed

    Klink, Thorsten; Geiger, Julia; Both, Marcus; Ness, Thomas; Heinzelmann, Sonja; Reinhard, Matthias; Holl-Ulrich, Konstanze; Duwendag, Dirk; Vaith, Peter; Bley, Thorsten Alexander

    2014-12-01

    To assess the diagnostic accuracy of contrast material-enhanced magnetic resonance (MR) imaging of superficial cranial arteries in the initial diagnosis of giant cell arteritis ( GCA giant cell arteritis ). Following institutional review board approval and informed consent, 185 patients suspected of having GCA giant cell arteritis were included in a prospective three-university medical center trial. GCA giant cell arteritis was diagnosed or excluded clinically in all patients (reference standard [final clinical diagnosis]). In 53.0% of patients (98 of 185), temporal artery biopsy ( TAB temporal artery biopsy ) was performed (diagnostic standard [ TAB temporal artery biopsy ]). Two observers independently evaluated contrast-enhanced T1-weighted MR images of superficial cranial arteries by using a four-point scale. Diagnostic accuracy, involvement pattern, and systemic corticosteroid ( sCS systemic corticosteroid ) therapy effects were assessed in comparison with the reference standard (total study cohort) and separately in comparison with the diagnostic standard TAB temporal artery biopsy ( TAB temporal artery biopsy subcohort). Statistical analysis included diagnostic accuracy parameters, interobserver agreement, and receiver operating characteristic analysis. Sensitivity of MR imaging was 78.4% and specificity was 90.4% for the total study cohort, and sensitivity was 88.7% and specificity was 75.0% for the TAB temporal artery biopsy subcohort (first observer). Diagnostic accuracy was comparable for both observers, with good interobserver agreement ( TAB temporal artery biopsy subcohort, κ = 0.718; total study cohort, κ = 0.676). MR imaging scores were significantly higher in patients with GCA giant cell arteritis -positive results than in patients with GCA giant cell arteritis -negative results ( TAB temporal artery biopsy subcohort and total study cohort, P < .001). Diagnostic accuracy of MR imaging was high in patients without and with sCS systemic corticosteroid therapy for 5 days or fewer (area under the curve, ≥0.9) and was decreased in patients receiving sCS systemic corticosteroid therapy for 6-14 days. In 56.5% of patients with TAB temporal artery biopsy -positive results (35 of 62), MR imaging displayed symmetrical and simultaneous inflammation of arterial segments. MR imaging of superficial cranial arteries is accurate in the initial diagnosis of GCA giant cell arteritis . Sensitivity probably decreases after more than 5 days of sCS systemic corticosteroid therapy; thus, imaging should not be delayed. Clinical trial registration no. DRKS00000594 . © RSNA, 2014.

  11. A comparison of different chemometrics approaches for the robust classification of electronic nose data.

    PubMed

    Gromski, Piotr S; Correa, Elon; Vaughan, Andrew A; Wedge, David C; Turner, Michael L; Goodacre, Royston

    2014-11-01

    Accurate detection of certain chemical vapours is important, as these may be diagnostic for the presence of weapons, drugs of misuse or disease. In order to achieve this, chemical sensors could be deployed remotely. However, the readout from such sensors is a multivariate pattern, and this needs to be interpreted robustly using powerful supervised learning methods. Therefore, in this study, we compared the classification accuracy of four pattern recognition algorithms which include linear discriminant analysis (LDA), partial least squares-discriminant analysis (PLS-DA), random forests (RF) and support vector machines (SVM) which employed four different kernels. For this purpose, we have used electronic nose (e-nose) sensor data (Wedge et al., Sensors Actuators B Chem 143:365-372, 2009). In order to allow direct comparison between our four different algorithms, we employed two model validation procedures based on either 10-fold cross-validation or bootstrapping. The results show that LDA (91.56% accuracy) and SVM with a polynomial kernel (91.66% accuracy) were very effective at analysing these e-nose data. These two models gave superior prediction accuracy, sensitivity and specificity in comparison to the other techniques employed. With respect to the e-nose sensor data studied here, our findings recommend that SVM with a polynomial kernel should be favoured as a classification method over the other statistical models that we assessed. SVM with non-linear kernels have the advantage that they can be used for classifying non-linear as well as linear mapping from analytical data space to multi-group classifications and would thus be a suitable algorithm for the analysis of most e-nose sensor data.

  12. Accuracy of the Defining Characteristics of the Nursing Diagnosis Hypothermia in Newborns.

    PubMed

    de Aquino, Wislla Ketlly Menezes; Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; Fróes, Nathaly Bianka Moraes; de Menezes, Angélica Paixão; Almeida, Aline de Aquino Peres; Sobreira, Bianca Alves

    2017-09-18

    To analyze the accuracy of the defining characteristics of hypothermia in newborns and to verify associations between defining characteristics and clinical variables. A cross-sectional accuracy study with statistical analysis. Slow capillary refill, decrease in ventilation, peripheral vasoconstriction, and insufficient weight gain were the defining characteristics with the highest specificity values, while slow gastric emptying, skin cool to touch, irritability, and bradycardia were the defining characteristics with the highest values for both sensitivity and specificity. Slow gastric emptying, skin cool to touch, irritability, and bradycardia are good clinical indicators to infer initial stages of hypothermia and to confirm its presence. Accuracy measures may contribute to the improvement of the diagnostic inferential process. Analisar acurácia das características definidoras de Hipotermia em recém-nascidos e identificar a associação delas com variáveis clínicas. MÉTODO: Estudo de acurácia transversal com análise estatística. Preenchimento capilar lento, diminuição da ventilação, vasoconstrição periférica e ganho de peso insuficiente apresentaram valores altos de especificidade enquanto esvaziamento gástrico lento, pele fria, irritabilidade e bradicardia apresentaram valores elevados de sensibilidade e especificidade. CONCLUSÃO: Esvaziamento gástrico lento, pele fria, irritabilidade e bradicardia são úteis para inferir estágios iniciais de hipotermia e para confirmação diagnóstica. IMPLICAÇÕES PARA PRÁTICA DE ENFERMAGEM: Medidas de acurácia podem contribuir para o processo de inferência do diagnóstico hipotermia. © 2017 NANDA International, Inc.

  13. Clinically inappropriate post hoc exclusion of study participants from test accuracy calculations: the ROMA score, an example from a recent NICE diagnostic assessment.

    PubMed

    Lang, Shona; Armstrong, Nigel; Deshpande, Sohan; Ramaekers, Bram; Grimm, Sabine; de Kock, Shelley; Kleijnen, Jos; Westwood, Marie

    2018-01-01

    Objective To explore how the definition of the target condition and post hoc exclusion of participants can limit the usefulness of diagnostic accuracy studies. Methods We used data from a systematic review, conducted for a NICE diagnostic assessment of risk scores to inform secondary care decisions about specialist referral for women with suspected ovarian cancer, to explore how the definition of the target condition and post hoc exclusion of participants can limit the usefulness of diagnostic accuracy studies to inform clinical practice. Results Fourteen of the studies evaluated the ROMA score, nine used Abbott ARCHITECT tumour marker assays, five used Roche Elecsys. The summary sensitivity estimate (Abbott ARCHITECT) was highest, 95.1% (95% CI: 92.4 to 97.1%), where analyses excluded participants with borderline tumours or malignancies other than epithelial ovarian cancer and lowest, 75.0% (95% CI: 60.4 to 86.4%), where all participants were included. Results were similar for Roche Elecsys tumour marker assays. Although the number of patients involved was small, data from studies that reported diagnostic accuracy for both the whole study population and with post hoc exclusion of those with borderline or non-epithelial malignancies suggested that patients with borderline or malignancies other than epithelial ovarian cancer accounts for between 50 and 85% of false-negative ROMA scores. Conclusions Our results illustrate the potential consequences of inappropriate population selection in diagnostic studies; women with non-epithelial ovarian cancers or non-ovarian primaries, and those borderline tumours may be disproportionately represented among those with false negative, 'low risk' ROMA scores. These observations highlight the importance of giving careful consideration to how the target condition has been defined when assessing whether the diagnostic accuracy estimates reported in clinical studies will translate into clinical utility in real-world settings.

  14. Diagnostic accuracy of lymphoma established by fine-needle aspiration cytological biopsy

    NASA Astrophysics Data System (ADS)

    Delyuzar; Amir, Z.; Suryadi, D.

    2018-03-01

    Based on Globocan data in 2012, it is estimated that about 14,495 Indonesians suffer from lymphoma, both Hodgkin’s lymphoma, and non-Hodgkin’s lymphoma. Some areas of specialization still doubt the accuracy of cytology diagnosis of fine needle aspiration biopsy.This study is a diagnostic test with a cross sectional analytic design to see how the cytology diagnostic accuracy of fine needle aspiration aspirate in lymphoma. It was in Department of Anatomical Pathology Faculty of Medicine USU, Haji Adam Malik Hospital, Dr.Pirngadi hospital, or private clinic in Medan. Peripheral cytology technique biopsy of fine needle aspiration on lymph node subsequently stained with Giemsa, when the cytology of lymphoma is obtained and confirmed by histopathologic examination. Cytology and histopathologic examination will be tested by Diagnostic Test and assessed for its sensitivity and specificity. The diagnostic of lymphoma cytology provides 93.33% sensitivity and 92.31% specificity when confirmed by histopathological examination. Positive predictive value and negative predictive value of 96.55% and 85.71% respectively. In conclusion, the cytology of fine needle aspiration biopsy is accurate enough to be used as a diagnostic tool, so it is advisable to establish a lymphoma diagnosis to perform a needle aspiration biopsy examination.

  15. Performance of seven serological assays for diagnosing tularemia

    PubMed Central

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  16. Diagnostic Accuracy of Multivariate Universal Screening Procedures for Reading in Upper Elementary Grades

    ERIC Educational Resources Information Center

    Klingbeil, David A.; Nelson, Peter M.; Van Norman, Ethan R.; Birr, Chris

    2017-01-01

    We examined the diagnostic accuracy and efficiency of three approaches to universal screening for reading difficulties using retrospective data from 1,307 students in Grades 3 through 5. School staff collected screening data using the Measures of Academic Progress (MAP), a curriculum-based measure (CBM), and running records (RR). The criterion…

  17. The Confidence-Accuracy Relationship in Diagnostic Assessment: The Case of the Potential Difference in Parallel Electric Circuits

    ERIC Educational Resources Information Center

    Saglam, Murat

    2015-01-01

    This study explored the relationship between accuracy of and confidence in performance of 114 prospective primary school teachers in answering diagnostic questions on potential difference in parallel electric circuits. The participants were required to indicate their confidence in their answers for each question. Bias and calibration indices were…

  18. Effect of data compression on diagnostic accuracy in digital hand and chest radiography

    NASA Astrophysics Data System (ADS)

    Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita

    1992-05-01

    Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.

  19. Accuracy of the Canadian C-spine rule and NEXUS to screen for clinically important cervical spine injury in patients following blunt trauma: a systematic review

    PubMed Central

    Michaleff, Zoe A.; Maher, Chris G.; Verhagen, Arianne P.; Rebbeck, Trudy; Lin, Chung-Wei Christine

    2012-01-01

    Background: There is uncertainty about the optimal approach to screen for clinically important cervical spine (C-spine) injury following blunt trauma. We conducted a systematic review to investigate the diagnostic accuracy of the Canadian C-spine rule and the National Emergency X-Radiography Utilization Study (NEXUS) criteria, 2 rules that are available to assist emergency physicians to assess the need for cervical spine imaging. Methods: We identified studies by an electronic search of CINAHL, Embase and MEDLINE. We included articles that reported on a cohort of patients who experienced blunt trauma and for whom clinically important cervical spine injury detectable by diagnostic imaging was the differential diagnosis; evaluated the diagnostic accuracy of the Canadian C-spine rule or NEXUS or both; and used an adequate reference standard. We assessed the methodologic quality using the Quality Assessment of Diagnostic Accuracy Studies criteria. We used the extracted data to calculate sensitivity, specificity, likelihood ratios and post-test probabilities. Results: We included 15 studies of modest methodologic quality. For the Canadian C-spine rule, sensitivity ranged from 0.90 to 1.00 and specificity ranged from 0.01 to 0.77. For NEXUS, sensitivity ranged from 0.83 to 1.00 and specificity ranged from 0.02 to 0.46. One study directly compared the accuracy of these 2 rules using the same cohort and found that the Canadian C-spine rule had better accuracy. For both rules, a negative test was more informative for reducing the probability of a clinically important cervical spine injury. Interpretation: Based on studies with modest methodologic quality and only one direct comparison, we found that the Canadian C-spine rule appears to have better diagnostic accuracy than the NEXUS criteria. Future studies need to follow rigorous methodologic procedures to ensure that the findings are as free of bias as possible. PMID:23048086

  20. Simultaneous fingerprint and high-wavenumber confocal Raman spectroscopy enhances early detection of cervical precancer in vivo.

    PubMed

    Duraipandian, Shiyamala; Zheng, Wei; Ng, Joseph; Low, Jeffrey J H; Ilancheran, A; Huang, Zhiwei

    2012-07-17

    Raman spectroscopy is a vibrational spectroscopic technique capable of nondestructively probing endogenous biomolecules and their changes associated with dysplastic transformation in the tissue. The main objectives of this study are (i) to develop a simultaneous fingerprint (FP) and high-wavenumber (HW) confocal Raman spectroscopy and (ii) to investigate its diagnostic utility for improving in vivo diagnosis of cervical precancer (dysplasia). We have successfully developed an integrated FP/HW confocal Raman diagnostic system with a ball-lens Raman probe for simultaneous acquistion of FP/HW Raman signals of the cervix in vivo within 1 s. A total of 476 in vivo FP/HW Raman spectra (356 normal and 120 precancer) are acquired from 44 patients at clinical colposcopy. The distinctive Raman spectral differences between normal and dysplastic cervical tissue are observed at ~854, 937, 1001, 1095, 1253, 1313, 1445, 1654, 2946, and 3400 cm(-1) mainly related to proteins, lipids, glycogen, nucleic acids and water content in tissue. Multivariate diagnostic algorithms developed based on partial least-squares-discriminant analysis (PLS-DA) together with the leave-one-patient-out, cross-validation yield the diagnostic sensitivities of 84.2%, 76.7%, and 85.0%, respectively; specificities of 78.9%, 73.3%, and 81.7%, respectively; and overall diagnostic accuracies of 80.3%, 74.2%, and 82.6%, respectively, using FP, HW, and integrated FP/HW Raman spectroscopic techniques for in vivo diagnosis of cervical precancer. Receiver operating characteristic (ROC) analysis further confirms the best performance of the integrated FP/HW confocal Raman technique, compared to FP or HW Raman spectroscopy alone. This work demonstrates, for the first time, that the simultaneous FP/HW confocal Raman spectroscopy has the potential to be a clinically powerful tool for improving early diagnosis and detection of cervical precancer in vivo during clinical colposcopic examination.

  1. bcROCsurface: an R package for correcting verification bias in estimation of the ROC surface and its volume for continuous diagnostic tests.

    PubMed

    To Duc, Khanh

    2017-11-18

    Receiver operating characteristic (ROC) surface analysis is usually employed to assess the accuracy of a medical diagnostic test when there are three ordered disease status (e.g. non-diseased, intermediate, diseased). In practice, verification bias can occur due to missingness of the true disease status and can lead to a distorted conclusion on diagnostic accuracy. In such situations, bias-corrected inference tools are required. This paper introduce an R package, named bcROCsurface, which provides utility functions for verification bias-corrected ROC surface analysis. The shiny web application of the correction for verification bias in estimation of the ROC surface analysis is also developed. bcROCsurface may become an important tool for the statistical evaluation of three-class diagnostic markers in presence of verification bias. The R package, readme and example data are available on CRAN. The web interface enables users less familiar with R to evaluate the accuracy of diagnostic tests, and can be found at http://khanhtoduc.shinyapps.io/bcROCsurface_shiny/ .

  2. Systematic review of patient history and physical examination to diagnose chronic low back pain originating from the facet joints.

    PubMed

    Maas, E T; Juch, J N S; Ostelo, R W J G; Groeneweg, J G; Kallewaard, J W; Koes, B W; Verhagen, A P; Huygen, F J P M; van Tulder, M W

    2017-03-01

    Patient history and physical examination are frequently used procedures to diagnose chronic low back pain (CLBP) originating from the facet joints, although the diagnostic accuracy is controversial. The aim of this systematic review is to determine the diagnostic accuracy of patient history and/or physical examination to identify CLBP originating from the facet joints using diagnostic blocks as reference standard. We searched MEDLINE, EMBASE, CINAHL, Web of Science and the Cochrane Collaboration database from inception until June 2016. Two review authors independently selected studies for inclusion, extracted data and assessed the risk of bias. We calculated sensitivity and specificity values, with 95% confidence intervals (95% CI). Twelve studies were included, in which 129 combinations of index tests and reference standards were presented. Most of these index tests have only been evaluated in single studies with a high risk of bias. Four studies evaluated the diagnostic accuracy of the Revel's criteria combination. Because of the clinical heterogeneity, results were not pooled. The published sensitivities ranged from 0.11 (95% CI 0.02-0.29) to 1.00 (95% CI 0.75-1.00), and the specificities ranged from 0.66 (95% CI 0.46-0.82) to 0.91 (95% CI 0.83-0.96). Due to clinical heterogeneity, the evidence for the diagnostic accuracy of patient history and/or physical examination to identify facet joint pain is inconclusive. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. © 2016 European Pain Federation - EFIC®.

  3. Neurobiological support to the diagnosis of ADHD in stimulant-naïve adults: pattern recognition analyses of MRI data.

    PubMed

    Chaim-Avancini, T M; Doshi, J; Zanetti, M V; Erus, G; Silva, M A; Duran, F L S; Cavallet, M; Serpa, M H; Caetano, S C; Louza, M R; Davatzikos, C; Busatto, G F

    2017-12-01

    In adulthood, the diagnosis of attention-deficit/hyperactivity disorder (ADHD) has been subject of recent controversy. We searched for a neuroanatomical signature associated with ADHD spectrum symptoms in adults by applying, for the first time, machine learning-based pattern classification methods to structural MRI and diffusion tensor imaging (DTI) data obtained from stimulant-naïve adults with childhood-onset ADHD and healthy controls (HC). Sixty-seven ADHD patients and 66 HC underwent high-resolution T1-weighted and DTI acquisitions. A support vector machine (SVM) classifier with a non-linear kernel was applied on multimodal image features extracted on regions of interest placed across the whole brain. The discrimination between a mixed-gender ADHD subgroup and individually matched HC (n = 58 each) yielded area-under-the-curve (AUC) and diagnostic accuracy (DA) values of up to 0.71% and 66% (P = 0.003) respectively. AUC and DA values increased to 0.74% and 74% (P = 0.0001) when analyses were restricted to males (52 ADHD vs. 44 HC). Introvert personality traits showed independent risk effects on suicidality regardless of diagnosis status. Among high risk individuals with suicidal thoughts, higher neuroticism tendency is further associated with increased risk of suicide attempt. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Should learners reason one step at a time? A randomised trial of two diagnostic scheme designs.

    PubMed

    Blissett, Sarah; Morrison, Deric; McCarty, David; Sibbald, Matthew

    2017-04-01

    Making a diagnosis can be difficult for learners as they must integrate multiple clinical variables. Diagnostic schemes can help learners with this complex task. A diagnostic scheme is an algorithm that organises possible diagnoses by assigning signs or symptoms (e.g. systolic murmur) to groups of similar diagnoses (e.g. aortic stenosis and aortic sclerosis) and provides distinguishing features to help discriminate between similar diagnoses (e.g. carotid pulse). The current literature does not identify whether scheme layouts should guide learners to reason one step at a time in a terminally branching scheme or weigh multiple variables simultaneously in a hybrid scheme. We compared diagnostic accuracy, perceptual errors and cognitive load using two scheme layouts for cardiac auscultation. Focused on the task of identifying murmurs on Harvey, a cardiopulmonary simulator, 86 internal medicine residents used two scheme layouts. The terminally branching scheme organised the information into single variable decisions. The hybrid scheme combined single variable decisions with a chart integrating multiple distinguishing features. Using a crossover design, participants completed one set of murmurs (diastolic or systolic) with either the terminally branching or the hybrid scheme. The second set of murmurs was completed with the other scheme. A repeated measures manova was performed to compare diagnostic accuracy, perceptual errors and cognitive load between the scheme layouts. There was a main effect of the scheme layout (Wilks' λ = 0.841, F 3,80 = 5.1, p = 0.003). Use of a terminally branching scheme was associated with increased diagnostic accuracy (65 versus 53%, p = 0.02), fewer perceptual errors (0.61 versus 0.98 errors, p = 0.001) and lower cognitive load (3.1 versus 3.5/7, p = 0.023). The terminally branching scheme was associated with improved diagnostic accuracy, fewer perceptual errors and lower cognitive load, suggesting that terminally branching schemes are effective for improving diagnostic accuracy. These findings can inform the design of schemes and other clinical decision aids. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  5. Enhanced CT images by the wavelet transform improving diagnostic accuracy of chest nodules.

    PubMed

    Guo, Xiuhua; Liu, Xiangye; Wang, Huan; Liang, Zhigang; Wu, Wei; He, Qian; Li, Kuncheng; Wang, Wei

    2011-02-01

    The objective of this study was to compare the diagnostic accuracy in the interpretation of chest nodules using original CT images versus enhanced CT images based on the wavelet transform. The CT images of 118 patients with cancers and 60 with benign nodules were used in this study. All images were enhanced through an algorithm based on the wavelet transform. Two experienced radiologists interpreted all the images in two reading sessions. The reading sessions were separated by a minimum of 1 month in order to minimize the effect of observer's recall. The Mann-Whitney U nonparametric test was used to analyze the interpretation results between original and enhanced images. The Kruskal-Wallis H nonparametric test of K independent samples was used to investigate the related factors which could affect the diagnostic accuracy of observers. The area under the ROC curves for the original and enhanced images was 0.681 and 0.736, respectively. There is significant difference in diagnosing the malignant nodules between the original and enhanced images (z = 7.122, P < 0.001), whereas there is no significant difference in diagnosing the benign nodules (z = 0.894, P = 0.371). The results showed that there is significant difference between original and enhancement images when the size of nodules was larger than 2 cm (Z = -2.509, P = 0.012, indicating the size of the nodules is a critical evaluating factor of the diagnostic accuracy of observers). This study indicated that the image enhancement based on wavelet transform could improve the diagnostic accuracy of radiologists for the malignant chest nodules.

  6. Evaluating radiographers' diagnostic accuracy in screen-reading mammograms: what constitutes a quality study?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debono, Josephine C, E-mail: josephine.debono@bci.org.au; Poulos, Ann E; Westmead Breast Cancer Institute, Westmead, New South Wales

    The aim of this study was to first evaluate the quality of studies investigating the diagnostic accuracy of radiographers as mammogram screen-readers and then to develop an adapted tool for determining the quality of screen-reading studies. A literature search was used to identify relevant studies and a quality evaluation tool constructed by combining the criteria for quality of Whiting, Rutjes, Dinnes et al. and Brealey and Westwood. This constructed tool was then applied to the studies and subsequently adapted specifically for use in evaluating quality in studies investigating diagnostic accuracy of screen-readers. Eleven studies were identified and the constructed toolmore » applied to evaluate quality. This evaluation resulted in the identification of quality issues with the studies such as potential for bias, applicability of results, study conduct, reporting of the study and observer characteristics. An assessment of the applicability and relevance of the tool for this area of research resulted in adaptations to the criteria and the development of a tool specifically for evaluating diagnostic accuracy in screen-reading. This tool, with further refinement and rigorous validation can make a significant contribution to promoting well-designed studies in this important area of research and practice.« less

  7. Combined diagnostic performance of coronary computed tomography angiography and computed tomography derived fractional flow reserve for the evaluation of myocardial ischemia: A meta-analysis.

    PubMed

    Tan, Xiao Wei; Zheng, Qishi; Shi, Luming; Gao, Fei; Allen, John Carson; Coenen, Adriaan; Baumann, Stefan; Schoepf, U Joseph; Kassab, Ghassan S; Lim, Soo Teik; Wong, Aaron Sung Lung; Tan, Jack Wei Chieh; Yeo, Khung Keong; Chin, Chee Tang; Ho, Kay Woon; Tan, Swee Yaw; Chua, Terrance Siang Jin; Chan, Edwin Shih Yen; Tan, Ru San; Zhong, Liang

    2017-06-01

    To evaluate the combined diagnostic accuracy of coronary computed tomography angiography (CCTA) and computed tomography derived fractional flow reserve (FFRct) in patients with suspected or known coronary artery disease (CAD). PubMed, The Cochrane library, Embase and OpenGray were searched to identify studies comparing diagnostic accuracy of CCTA and FFRct. Diagnostic test measurements of FFRct were either extracted directly from the published papers or calculated from provided information. Bivariate models were conducted to synthesize the diagnostic performance of combined CCTA and FFRct at both "per-vessel" and "per-patient" levels. 7 articles were included for analysis. The combined diagnostic outcomes from "both positive" strategy, i.e. a subject was considered as "positive" only when both CCTA and FFRct were "positive", demonstrated relative high specificity (per-vessel: 0.91; per-patient: 0.81), high positive likelihood ratio (LR+, per-vessel: 7.93; per-patient: 4.26), high negative likelihood ratio (LR-, per-vessel: 0.30; per patient: 0.24) and high accuracy (per-vessel: 0.91; per-patient: 0.81) while "either positive" strategy, i.e. a subject was considered as "positive" when either CCTA or FFRct was "positive", demonstrated relative high sensitivity (per-vessel: 0.97; per-patient: 0.98), low LR+ (per-vessel: 1.50; per-patient: 1.17), low LR- (per-vessel: 0.07; per-patient: 0.09) and low accuracy (per-vessel: 0.57; per-patient: 0.54). "Both positive" strategy showed better diagnostic performance to rule in patients with non-significant stenosis compared to "either positive" strategy, as it efficiently reduces the proportion of testing false positive subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial

    PubMed Central

    Di Santo, Pietro; Harnett, David T.; Simard, Trevor; Ramirez, F. Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G.; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong

    2018-01-01

    BACKGROUND: Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. METHODS: We compared the modified Allen test with a smartphone heart rate–monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient’s index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate–monitoring application. RESULTS: Among 438 patients who were included in the study, we found that the heart rate–monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). INTERPRETATION: A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient’s bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. PMID:29615421

  9. A Comparative Study on Diagnostic Accuracy of Colour Coded Digital Images, Direct Digital Images and Conventional Radiographs for Periapical Lesions – An In Vitro Study

    PubMed Central

    Mubeen; K.R., Vijayalakshmi; Bhuyan, Sanat Kumar; Panigrahi, Rajat G; Priyadarshini, Smita R; Misra, Satyaranjan; Singh, Chandravir

    2014-01-01

    Objectives: The identification and radiographic interpretation of periapical bone lesions is important for accurate diagnosis and treatment. The present study was undertaken to study the feasibility and diagnostic accuracy of colour coded digital radiographs in terms of presence and size of lesion and to compare the diagnostic accuracy of colour coded digital images with direct digital images and conventional radiographs for assessing periapical lesions. Materials and Methods: Sixty human dry cadaver hemimandibles were obtained and periapical lesions were created in first and second premolar teeth at the junction of cancellous and cortical bone using a micromotor handpiece and carbide burs of sizes 2, 4 and 6. After each successive use of round burs, a conventional, RVG and colour coded image was taken for each specimen. All the images were evaluated by three observers. The diagnostic accuracy for each bur and image mode was calculated statistically. Results: Our results showed good interobserver (kappa > 0.61) agreement for the different radiographic techniques and for the different bur sizes. Conventional Radiography outperformed Digital Radiography in diagnosing periapical lesions made with Size two bur. Both were equally diagnostic for lesions made with larger bur sizes. Colour coding method was least accurate among all the techniques. Conclusion: Conventional radiography traditionally forms the backbone in the diagnosis, treatment planning and follow-up of periapical lesions. Direct digital imaging is an efficient technique, in diagnostic sense. Colour coding of digital radiography was feasible but less accurate however, this imaging technique, like any other, needs to be studied continuously with the emphasis on safety of patients and diagnostic quality of images. PMID:25584318

  10. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial.

    PubMed

    Di Santo, Pietro; Harnett, David T; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong; Hibbert, Benjamin

    2018-04-03

    Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. We compared the modified Allen test with a smartphone heart rate-monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient's index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate-monitoring application. Among 438 patients who were included in the study, we found that the heart rate-monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient's bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. © 2018 Joule Inc. or its licensors.

  11. Accuracy of a Rapid Diagnostic Test (Cypress Chagas Quick Test®) for the Diagnosis of Chronic Chagas Disease in a Nonendemic Area: A Retrospective Longitudinal Study.

    PubMed

    Angheben, Andrea; Staffolani, Silvia; Anselmi, Mariella; Tais, Stefano; Degani, Monica; Gobbi, Federico; Buonfrate, Dora; Gobbo, Maria; Bisoffi, Zeno

    2017-11-01

    We analyzed the accuracy of Chagas Quick Test ® , a rapid diagnostic test, for the diagnosis of chronic Chagas disease through a retrospective study on a cohort of 669 patients consecutively examined at a single reference center in Italy, during a 7-year period. We observed high concordance with serological reference standard but low accuracy for screening purposes (sensitivity/specificity: 82.8%/98.7%) at least in our nonendemic context.

  12. Combining independent decisions increases diagnostic accuracy of reading lumbosacral radiographs and magnetic resonance imaging.

    PubMed

    Kurvers, Ralf H J M; de Zoete, Annemarie; Bachman, Shelby L; Algra, Paul R; Ostelo, Raymond

    2018-01-01

    Diagnosing the causes of low back pain is a challenging task, prone to errors. A novel approach to increase diagnostic accuracy in medical decision making is collective intelligence, which refers to the ability of groups to outperform individual decision makers in solving problems. We investigated whether combining the independent ratings of chiropractors, chiropractic radiologists and medical radiologists can improve diagnostic accuracy when interpreting diagnostic images of the lumbosacral spine. Evaluations were obtained from two previously published studies: study 1 consisted of 13 raters independently rating 300 lumbosacral radiographs; study 2 consisted of 14 raters independently rating 100 lumbosacral magnetic resonance images. In both studies, raters evaluated the presence of "abnormalities", which are indicators of a serious health risk and warrant immediate further examination. We combined independent decisions of raters using a majority rule which takes as final diagnosis the decision of the majority of the group. We compared the performance of the majority rule to the performance of single raters. Our results show that with increasing group size (i.e., increasing the number of independent decisions) both sensitivity and specificity increased in both data-sets, with groups consistently outperforming single raters. These results were found for radiographs and MR image reading alike. Our findings suggest that combining independent ratings can improve the accuracy of lumbosacral diagnostic image reading.

  13. Diagnostic value of N-terminal pro-brain natriuretic peptide for pleural effusion due to heart failure: a meta-analysis.

    PubMed

    Zhou, Q; Ye, Z J; Su, Y; Zhang, J C; Shi, H Z

    2010-08-01

    N-terminal pro-brain natriuretic peptide (NT-proBNP) is a biomarker useful in diagnosis of pleural effusion due to heart failure. Thus far, its overall diagnostic accuracy has not been systematically reviewed. The aim of the present meta-analysis was to establish the overall diagnostic accuracy of the measurement of pleural NT-proBNP for identifying pleural effusion due to heart failure. After a systematic review of English-language studies, sensitivity, specificity, and other measures of accuracy of NT-proBNP concentrations in pleural fluid in the diagnosis of pleural effusion resulting from heart failure were pooled using fixed-effects models. Summary receiver operating characteristic curves were used to summarise overall test performance. Eight publications met the inclusion criteria. The summary estimates for pleural NT-proBNP in the diagnosis of pleural effusion attributable to heart failure were: sensitivity 0.95 (95% CI 0.92 to 0.97), specificity 0.94 (0.92 to 0.96), positive likelihood ratio 14.12 (10.23 to 19.51), negative likelihood ratio 0.06 (0.04 to 0.09) and diagnostic OR 213.87 (122.50 to 373.40). NT-proBNP levels in pleural fluid showed a high diagnostic accuracy and may help accurately differentiate cardiac from non-cardiac conditions in patients presenting with pleural effusion.

  14. Immunohistochemical identification of varicella-zoster virus gene 63-encoded protein (IE63) and late (gE) protein on smears and cutaneous biopsies: implications for diagnostic use.

    PubMed

    Nikkels, A F; Debrus, S; Sadzot-Delvaux, C; Piette, J; Rentier, B; Piérard, G E

    1995-12-01

    Early and specific recognition of varicella zoster virus (VZV) infection is of vital concern in immunocompromised patients. The aim of this study was to compare the diagnostic accuracy of histochemical and immunohistochemical identification of the VZV ORF63 encoded protein (IE63) and of the VZV late protein gE on smears and formalin-fixed paraffin-embedded skin sections taken from lesions clinically diagnosed as varicella (n = 15) and herpes zoster (n = 51). Microscopic examinations of Tzanck smears and skin sections yielded a diagnostic accuracy of Herpesviridae infections in 66.7% (10/15) and 92.3% (12/13) of varicella, and 74.4% (29/39) and 87.8% (43/49) of herpes zoster, respectively. Immunohistochemistry applied to varicella provided a type-specific virus diagnostic accuracy of 86.7% (13/15; IE63) and 100% (15/15; gE) on smears, and of 92.3% for both VZV proteins on skin sections. In herpes zoster, the diagnostic accuracy of immunohistochemistry reached 92.3% (36/39; IE63) and 94.9% (37/39; gE) on smears, and 91.7% (44/48; IE63) and 91.8% (45/49; gE) on skin sections. These findings indicate that the immunohistochemical detection of IE63 and gE on both smears and skin sections yields a higher specificity and sensitivity than standard microscopic assessments.

  15. Diagnostic Criteria and Accuracy of Categorizing Malignant Thyroid Nodules by Ultrasonography and Ultrasound Elastography with Pathologic Correlation.

    PubMed

    Elsayed, Naglaa Mostafa; Elkhatib, Yasser Atta

    2016-03-01

    Thyroid nodules are a common medical and surgical concern. Thyroid ultrasound (US) is the primary imaging modality used for initial evaluation and assortment of nodules for fine needle aspiration (FNA) cytology/biopsy. Ultrasound elastography (USE) is believed to improve the diagnostic accuracy of US in distinguishing benign from malignant nodules. The aim of the work described here is to evaluate the diagnostic criteria and accuracy of US and USE in the diagnosis of malignant thyroid nodules. A prospective study of 88 patients who have thyroid nodules was performed. US, color Doppler, and USE were evaluated using a Philips iU22 equipped with a 5 to 12 MHz, linear transducer, followed by FNA of the each scanned nodule. The most sensitive US criteria for malignant nodules were a height-to-width ratio greater than one and the absence of a halo sign (sensitivity 0.875% and 1.000%, respectively). The most specific criteria for malignancy were a spiculated/blurred margin and the presence of microcalcifications (specificity 0.968% and 0.888%, respectively). The receiver operating characteristic curve showed that the cutoff diagnostic criteria of malignancy are two US characteristics and an elastography score of 4. The diagnostic accuracy of US for malignant thyroid nodules increases by combining US and USE. © The Author(s) 2015.

  16. Diagnostic accuracy of magnetic resonance imaging, transvaginal, and transrectal ultrasonography in deep infiltrating endometriosis

    PubMed Central

    Alborzi, Saeed; Rasekhi, Alireza; Shomali, Zahra; Madadi, Gooya; Alborzi, Mahshid; Kazemi, Mahboobeh; Hosseini Nohandani, Azam

    2018-01-01

    Abstract To determine the diagnostic accuracy of pelvic magnetic resonance imaging (MRI), transvaginal sonography (TVS), and transrectal sonography (TRS) in diagnosis of deep infiltrating endometriosis (DIE). This diagnostic accuracy study was conducted during a 2-year period including a total number of 317 patients with signs and symptoms of endometriosis. All the patients were evaluated by pelvic MRI, TVS, and TRS in the same center. The criterion standard was considered to be the laparoscopy and histopathologic examination. Of 317 patients being included in the present study, 252 tested positive for DIE. The sensitivity, specificity, positive predictive value, and negative predictive value of TVS was found to be 83.3%, 46.1%, 85.7%, and 41.6%, respectively. These variables were 80.5%, 18.6%, 79.3%, and 19.7% for TRS and 90.4%, 66.1%, 91.2%, and 64.1% for MRI, respectively. MRI had the highest accuracy (85.4%) when compared to TVS (75.7%) and TRS (67.8%). The sensitivity of TRS, TVS, and MRI in uterosacral ligament DIE was 82.8%, 70.9%, and 63.6%, respectively. On the contrary, specificity had a reverse trend, favoring MRI (93.9%, 92.8%, and 89.8% for TVS and TRS, respectively). The results of the present study demonstrated that TVS and TRS have appropriate diagnostic accuracy in diagnosis of DIE comparable to MRI. PMID:29465552

  17. Diagnostic accuracy of CT in assessing extra-regional lymphadenopathy in pancreatic and peri-ampullary cancer: a systematic review and meta-analysis.

    PubMed

    Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus

    2014-12-01

    Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. 16 kDa heat shock protein from heat-inactivated Mycobacterium tuberculosis is a homodimer - suitability for diagnostic applications with specific llama VHH monoclonals.

    PubMed

    Srivastava, Saurabh K; Ruigrok, Vincent J B; Thompson, Natalie J; Trilling, Anke K; Heck, Albert J R; van Rijn, Cees; Beekwilder, Jules; Jongsma, Maarten A

    2013-01-01

    The 16 kDa heat shock protein (HSP) is an immuno-dominant antigen, used in diagnosis of infectious Mycobacterium tuberculosis (M.tb.) causing tuberculosis (TB). Its use in serum-based diagnostics is limited, but for the direct identification of M.tb. bacteria in sputum or cultures it may represent a useful tool. Recently, a broad set of twelve 16 kDa specific heavy chain llama antibodies (VHH) has been isolated, and their utility for diagnostic applications was explored. To identify the epitopes recognized by the nine (randomly selected from a set of twelve 16 kDa specific VHH antibodies) distinct VHH antibodies, 14 overlapping linear epitopes (each 20 amino acid long) were characterized using direct and sandwich ELISA techniques. Seven out of 14 epitopes were recognized by 8 out of 9 VHH antibodies. The two highest affinity binders B-F10 and A-23 were found to bind distinct epitopes. Sandwich ELISA and SPR experiments showed that only B-F10 was suitable as secondary antibody with both B-F10 and A-23 as anchoring antibodies. To explain this behavior, the epitopes were matched to the putative 3D structure model. Electrospray ionization time-of-flight mass spectrometry and size exclusion chromatography were used to determine the higher order conformation. A homodimer model best explained the differential immunological reactivity of A-23 and B-F10 against heat-treated M.tb. lysates. The concentrations of secreted antigens of M.tb. in sputum are too low for immunological detection and existing kits are only used for identifying M.tb. in cultures. Here we describe how specific combinations of VHH domains could be used to detect the intracellular HSP antigen. Linked to methods of pre-concentrating M.tb. cells prior to lysis, HSP detection may enable the development of protein-based diagnostics of sputum samples and earlier diagnosis of diseases.

  19. The usefulness of the sum of relative enhancement ratio in making a differential diagnosis of hepatocellular carcinoma from cirrhosis-related nodules.

    PubMed

    Yoon, Ki Woong; Song, Ji Soo; Han, Young Min

    2014-01-01

    To estimate the diagnostic accuracy of the sum of relative enhancement ratio (sRER) in making a differential diagnosis of hepatocellular carcinoma (HCC) from benign cirrhosis-related nodules. Eighteen benign cirrhosis-related nodules and 18 HCCs were evaluated. Three radiologists independently reviewed computed tomography images using visual assessment and sRER. sRER was estimated by adding region-of-interest measurement in the arterial phase and the delayed phase. Diagnostic performance and accuracy were evaluated. The mean values of sRER were significantly higher in HCCs than in benign cirrhosis-related nodules. The sRER method improved diagnostic accuracy of differentiating HCCs from benign cirrhosis-related nodules. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Rapid Trace Detection and Isomer Quantitation of Pesticide Residues via Matrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

    PubMed

    Wu, Xinzhou; Li, Weifeng; Guo, Pengran; Zhang, Zhixiang; Xu, Hanhong

    2018-04-18

    Matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS) has been applied for rapid, sensitive, undisputed, and quantitative detection of pesticide residues on fresh leaves with little sample pretreatment. Various pesticides (insecticides, bactericides, herbicides, and acaricides) are detected directly in the complex matrix with excellent limits of detection down to 4 μg/L. FTICR-MS could unambiguously identify pesticides with tiny mass differences (∼0.017 75 Da), thereby avoiding false-positive results. Remarkably, pesticide isomers can be totally discriminated by use of diagnostic fragments, and quantitative analysis of pesticide isomers is demonstrated. The present results expand the horizons of the MALDI-FTICR-MS platform in the reliable determination of pesticides, with integrated advantages of ultrahigh mass resolution and accuracy. This method provides growing evidence for the resultant detrimental effects of pesticides, expediting the identification and evaluation of innovative pesticides.

  1. Evaluation and Characterization of Fasciola hepatica Tegument Protein Extract for Serodiagnosis of Human Fascioliasis

    PubMed Central

    Morales, Adelaida

    2012-01-01

    Tegument protein extract from Fasciola hepatica adult flukes (FhTA) was obtained and assessed for its potential as a diagnostic agent for the serological detection of human fascioliasis using an indirect enzyme-linked immunosorbent assay (ELISA). In an analysis of sera from 45 patients infected with F. hepatica, sera from 41 patients with other parasitic infections, and sera from 33 healthy controls, the FhTA-ELISA showed sensitivity, specificity, and accuracy of 91.1%, 97.3%, and 95%, respectively. Specific IgG1 and IgG4 were the antibody isotypes mainly detected in sera from patients with fascioliasis. Polypeptides of 52, 38, 24 to 26, and 12 to 14 kDa were identified by Western blotting as the most immunoreactive components of the FhTA. A proteomic approach led us to identify enolase, aldolase, glutathione S-transferase, and fatty acid binding protein as the major immunoreactive components of the FhTA. PMID:23015645

  2. Diagnostic value of rectal suction biopsies using calretinin immunohistochemical staining in Hirschsprung's disease.

    PubMed

    Tran, Viet Quoc; Lam, Kim Thien; Truong, Dinh Quang; Dang, Minh Hoang; Doan, Thao Thi Phuong; Segers, Valerie; Butler, Marilyn West; Robert, Annie; Goyens, Philippe; Steyaert, Henri

    2016-12-01

    The study investigates the diagnostic value of calretinin immunohistochemical staining (CIS) on rectal suction biopsies (RSB) in Hirschsprung's disease (HD). A prospective study was conducted at Children's Hospital 2 in Ho Chi Minh City, Vietnam, from January through December 2015. Patients suspected of HD during this period underwent RSB and were followed in order to assess the accuracy of the diagnostic test with CIS compared with conventional histology (H&E). A total of 188 children with RSB were investigated. Median age was 7.1 (range 0.2-159) months with 65.4% boys. HD was confirmed in 80 (42.6%) children. There were 1 false positive and no false-negative cases. The sensitivity and specificity were 100% (80/80) and 99.1% (107/108) for CIS and 100% and 85.2% for H&E, respectively. Cohen's kappa coefficient was 0.9891 with a diagnostic accuracy of 99.5% for CIS, compared with 0.8303 and 91.5% for H&E, respectively. There were no serious complications related to the RSB. RSB with CIS is a useful diagnostic method for HD, with easy interpretation and no need for cryostat. CIS has a high diagnostic accuracy and should be considered as the primary method for the diagnosis of HD by RSB. Diagnostic Studies - Level I. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Molecular malaria diagnostics: A systematic review and meta-analysis.

    PubMed

    Roth, Johanna M; Korevaar, Daniël A; Leeflang, Mariska M G; Mens, Pètra F

    2016-01-01

    Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.

  4. Dental and dental hygiene students' diagnostic accuracy in oral radiology: effect of diagnostic strategy and instructional method.

    PubMed

    Baghdady, Mariam T; Carnahan, Heather; Lam, Ernest W N; Woods, Nicole N

    2014-09-01

    There has been much debate surrounding diagnostic strategies and the most appropriate training models for novices in oral radiology. It has been argued that an analytic approach, using a step-by-step analysis of the radiographic features of an abnormality, is ideal. Alternative research suggests that novices can successfully employ non-analytic reasoning. Many of these studies do not take instructional methodology into account. This study evaluated the effectiveness of non-analytic and analytic strategies in radiographic interpretation and explored the relationship between instructional methodology and diagnostic strategy. Second-year dental and dental hygiene students were taught four radiographic abnormalities using basic science instructions or a step-by-step algorithm. The students were tested on diagnostic accuracy and memory immediately after learning and one week later. A total of seventy-three students completed both immediate and delayed sessions and were included in the analysis. Students were randomly divided into two instructional conditions: one group provided a diagnostic hypothesis for the image and then identified specific features to support it, while the other group first identified features and then provided a diagnosis. Participants in the diagnosis-first condition (non-analytic reasoning) had higher diagnostic accuracy then those in the features-first condition (analytic reasoning), regardless of their learning condition. No main effect of learning condition or interaction with diagnostic strategy was observed. Educators should be mindful of the potential influence of analytic and non-analytic approaches on the effectiveness of the instructional method.

  5. Receiver operating characteristic (ROC) curves: review of methods with applications in diagnostic medicine

    NASA Astrophysics Data System (ADS)

    Obuchowski, Nancy A.; Bullen, Jennifer A.

    2018-04-01

    Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.

  6. Dynamic Assessment of Narratives: Efficient, Accurate Identification of Language Impairment in Bilingual Students

    ERIC Educational Resources Information Center

    Petersen, Douglas B.; Chanthongthip, Helen; Ukrainetz, Teresa A.; Spencer, Trina D.; Steeve, Roger W.

    2017-01-01

    Purpose: This study investigated the classification accuracy of a concentrated English narrative dynamic assessment (DA) for identifying language impairment (LI). Method: Forty-two Spanish-English bilingual kindergarten to third-grade children (10 LI and 32 with no LI) were administered two 25-min DA test-teach-test sessions. Pre- and posttest…

  7. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference

    PubMed Central

    Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth

    2015-01-01

    Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275

  8. Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

    PubMed Central

    Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin

    2016-01-01

    Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196

  9. Systematic review of proposed definitions of nocturnal polyuria and population-based evidence of their diagnostic accuracy.

    PubMed

    Olesen, Tine Kold; Denys, Marie-Astrid; Vande Walle, Johan; Everaert, Karel

    2018-02-06

    Background Evidence of diagnostic accuracy for proposed definitions of nocturnal polyuria is currently unclear. Purpose Systematic review to determine population-based evidence of the diagnostic accuracy of proposed definitions of nocturnal polyuria based on data from frequency-volume charts. Methods Seventeen pre-specified search terms identified 351 unique investigations published from 1990 to 2016 in BIOSIS, Embase, Embase Alerts, International Pharmaceutical Abstract, Medline, and Cochrane. Thirteen original communications were included in this review based on pre-specified exclusion criteria. Data were extracted from each paper regarding subject age, sex, ethnicity, health status, sample size, data collection methods, and diagnostic discrimination of proposed definitions including sensitivity, specificity, positive and negative predictive value. Results The sample size of study cohorts, participant age, sex, ethnicity, and health status varied considerably in 13 studies reporting on the diagnostic performance of seven different definitions of nocturnal polyuria using frequency-volume chart data from 4968 participants. Most study cohorts were small, mono-ethnic, including only Caucasian males aged 50 or higher with primary or secondary polyuria that were compared to a control group of healthy men without nocturia in prospective or retrospective settings. Proposed definitions had poor discriminatory accuracy in evaluations based on data from subjects independent from the original study cohorts with findings being similar regarding the most widely evaluated definition endorsed by ICS. Conclusions Diagnostic performance characteristics for proposed definitions of nocturnal polyuria show poor to modest discrimination and are not based on sufficient level of evidence from representative, multi-ethnic population-based data from both females and males of all adult ages.

  10. The accuracy and cost-effectiveness of strategies used to identify peripheral artery disease among patients with diabetic foot ulcers.

    PubMed

    Barshes, Neal R; Flores, Everardo; Belkin, Michael; Kougias, Panos; Armstrong, David G; Mills, Joseph L

    2016-12-01

    Patients with diabetic foot ulcers (DFUs) should be evaluated for peripheral artery disease (PAD). We sought to estimate the overall diagnostic accuracy for various strategies that are used to identify PAD in this population. A Markov model with probabilistic and deterministic sensitivity analyses was used to simulate the clinical events in a population of 10,000 patients with diabetes. One of 14 different diagnostic strategies was applied to those who developed DFUs. Baseline data on diagnostic accuracy of individual noninvasive tests were based on a meta-analysis of previously reported studies. The overall sensitivity and cost-effectiveness of the 14 strategies were then compared. The overall sensitivity of various combinations of diagnostic testing strategies ranged from 32.6% to 92.6%. Cost-effective strategies included ankle-brachial indices for all patients; skin perfusion pressures (SPPs) or toe-brachial indices (TBIs) for all patients; and SPPs or TBIs to corroborate normal pulse examination findings, a strategy that lowered leg amputation rates by 36%. Strategies that used noninvasive vascular testing to investigate only abnormal pulse examination results had low overall diagnostic sensitivity and were weakly dominated in cost-effectiveness evaluations. Population prevalence of PAD did not alter strategy ordering by diagnostic accuracy or cost-effectiveness. TBIs or SPPs used uniformly or to corroborate a normal pulse examination finding are among the most sensitive and cost-effective strategies to improve the identification of PAD among patients presenting with DFUs. These strategies may significantly reduce leg amputation rates with only modest increases in cost. Published by Elsevier Inc.

  11. Assessing the dependence of sensitivity and specificity on prevalence in meta-analysis

    PubMed Central

    Li, Jialiang; Fine, Jason P.

    2011-01-01

    We consider modeling the dependence of sensitivity and specificity on the disease prevalence in diagnostic accuracy studies. Many meta-analyses compare test accuracy across studies and fail to incorporate the possible connection between the accuracy measures and the prevalence. We propose a Pearson type correlation coefficient and an estimating equation–based regression framework to help understand such a practical dependence. The results we derive may then be used to better interpret the results from meta-analyses. In the biomedical examples analyzed in this paper, the diagnostic accuracy of biomarkers are shown to be associated with prevalence, providing insights into the utility of these biomarkers in low- and high-prevalence populations. PMID:21525421

  12. Exploring cognitive integration of basic science and its effect on diagnostic reasoning in novices.

    PubMed

    Lisk, Kristina; Agur, Anne M R; Woods, Nicole N

    2016-06-01

    Integration of basic and clinical science knowledge is increasingly being recognized as important for practice in the health professions. The concept of 'cognitive integration' places emphasis on the value of basic science in providing critical connections to clinical signs and symptoms while accounting for the fact that clinicians may not spontaneously articulate their use of basic science knowledge in clinical reasoning. In this study we used a diagnostic justification test to explore the impact of integrated basic science instruction on novices' diagnostic reasoning process. Participants were allocated to an integrated basic science or clinical science training group. The integrated basic science group was taught the clinical features along with the underlying causal mechanisms of four musculoskeletal pathologies while the clinical science group was taught only the clinical features. Participants completed a diagnostic accuracy test immediately after initial learning, and one week later a diagnostic accuracy and justification test. The results showed that novices who learned the integrated causal mechanisms had superior diagnostic accuracy and better understanding of the relative importance of key clinical features. These findings further our understanding of cognitive integration by providing evidence of the specific changes in clinical reasoning when basic and clinical sciences are integrated during learning.

  13. Concurrent Validity and Diagnostic Accuracy of the Dynamic Indicators of Basic Early Literacy Skills and the Comprehensive Test of Phonological Processing

    ERIC Educational Resources Information Center

    Hintze, John M.; Ryan, Amanda L.; Stoner, Gary

    2003-01-01

    The purpose of this study was to (a) examine the concurrent validity of the Dynamic Indicators of Basic Early Literacy Skills (DIBELS) with the Comprehensive Test of Phonological Processing (CTOPP), and (b) explore the diagnostic accuracy of the DIBELS in predicting CTOPP performance using suggested and alternative cut-scores. Eighty-six students…

  14. The Screening Accuracy of the Parent and Teacher-Reported Social Responsiveness Scale (SRS): Comparison with the 3Di and ADOS

    ERIC Educational Resources Information Center

    Duvekot, Jorieke; van der Ende, Jan; Verhulst, Frank C.; Greaves-Lord, Kirstin

    2015-01-01

    The screening accuracy of the parent and teacher-reported Social Responsiveness Scale (SRS) was compared with an autism spectrum disorder (ASD) classification according to (1) the Developmental, Dimensional, and Diagnostic Interview (3Di), (2) the Autism Diagnostic Observation Schedule (ADOS), (3) both the 3Di and ADOS, in 186 children referred to…

  15. Accuracy of biochemical markers for predicting nasogastric tube placement in adults--a systematic review of diagnostic studies.

    PubMed

    Fernandez, Ritin S; Chau, Janita Pak-Chun; Thompson, David R; Griffiths, Rhonda; Lo, Hoi-Shan

    2010-08-01

    The objective of this study was to investigate the diagnostic performance of biochemical tests used to determine placement of nasogastric (NG) tubes after insertion in adults. A systematic review of diagnostic studies was undertaken. A literature search of the bibliographic databases and the World Wide Web was performed to locate original diagnostic studies in English or Chinese on biochemical markers for detecting NG tube location. Studies in which one or more different tests were evaluated with a reference standard, and diagnostic values were reported or could be calculated were included. Two reviewers independently checked all abstracts and full text studies for inclusion criteria. Included studies were assessed for their quality using the QUADAS tool. Study features and diagnostic values were extracted from the included studies. Of the 10 studies included in this review, seven investigated the diagnostic accuracy of pH, one investigated the diagnostic accuracy of pH and bilirubin respectively, two a combination of pH and bilirubin and one a combination of pH, pepsin and trypsin levels in identifying NG tube location. All studies used X-rays as the reference standard for comparison. Pooled results demonstrated that a pH of

  16. Diagnostic Accuracy of an MRI Protocol of the Knee Accelerated Through Parallel Imaging in Correlation to Arthroscopy.

    PubMed

    Schnaiter, Johannes Walter; Roemer, Frank; McKenna-Kuettner, Axel; Patzak, Hans-Joachim; May, Matthias Stefan; Janka, Rolf; Uder, Michael; Wuest, Wolfgang

    2018-03-01

     Parallel imaging allows for a considerable shortening of examination times. Limited data is available about the diagnostic accuracy of an accelerated knee MRI protocol based on parallel imaging evaluating all knee joint compartments in a large patient population compared to arthroscopy.  162 consecutive patients with a knee MRI (1.5 T, Siemens Aera) and arthroscopy were included. The total MRI scan time was less than 9 minutes. Meniscus and cartilage injuries, cruciate ligament lesions, loose joint bodies and medial patellar plicae were evaluated. Sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV), as well as diagnostic accuracy were determined.  For the medial meniscus, the values were: SE 97 %, SP 88 %, PPV 94 %, and NPV 94 %. For the lateral meniscus the values were: SE 77 %, SP 99 %, PPV 98 %, and NPV 89 %. For cartilage injuries the values were: SE 72 %, SP 80 %, PPV 86 %, and NPV 61 %. For the anterior cruciate ligament the values were: SE 90 %, SP 94 %, PPV 77 %, and NPV 98 %, while all values were 100 % for the posterior cruciate ligament. For loose bodies the values were: SE 48 %, SP 96 %, PPV 62 %, and NPV 93 %, and for the medial patellar plicae the values were: SE 57 %, SP 88 %, PPV 18 %, and NPV 98 %.  A knee MRI examination with parallel imaging and a scan time of less than 9 minutes delivers reliable results with high diagnostic accuracy.   · An accelerated knee MRI protocol with parallel imaging allows for high diagnostic accuracy.. · Especially meniscal and cruciate ligament injuries are well depicted.. · Cartilage injuries seem to be overestimated.. · Schnaiter JW, Roemer F, McKenna-Kuettner A et al. Diagnostic Accuracy of an MRI Protocol of the Knee Accelerated Through Parallel Imaging in Correlation to Arthroscopy. Fortschr Röntgenstr 2018; 190: 265 - 272. © Georg Thieme Verlag KG Stuttgart · New York.

  17. Usefulness of 8 kDa protein of Fasciola hepatica in diagnosis of fascioliasis

    PubMed Central

    Kim, Kwangsig; Yang, Hyun Jong

    2003-01-01

    This study was designed to detect and evaluate an antigenicity of low molecular weight proteins of Fasciola hepatica in fascioliasis. Low molecular weight protein of F. hepatica was purified by ammonium sulfate precipitation and Sephacryl S-100 HR gel filtration. The protein obtained was estimated to be 8 kDa on 7.5-15% gradient sodium dodecyl sulfate gel electrophoresis. Immunoblotting studies showed that the 8 kDa protein reacted with human fascioliasis sera, but not other trematodiasis sera. This result suggests that the 8 kDa protein of F. hepatica is one of diagnostic antigens in human fascioliasis without cross-reaction with other human trematodiasis. PMID:12815325

  18. [Evaluation of Trichinella cross-reactions in the serological diagnosis of toxocariasis].

    PubMed

    Ozkoç, Soykan; Bayram Delibaş, Songül; Akısü, Ciler

    2012-07-01

    Toxocariasis caused by the nematode larvae of the Toxocara genus is a worldwide parasitic zoonosis. Diagnosis of human toxocariasis commonly relies on serological tests since the symptoms and signs of Toxocara infection are not pathognomonic. However Toxocara larval excretory-secretory (TES) antigen used in serological tests may exhibit low specificity due to the cross-reactions between related helminth infections such as ascariasis, anisakiasis, strongyloidosis and filariasis. In this study, we aimed to evaluate the possible effect of Trichinella cross-reactions in the serological diagnosis of toxocariasis by using ELISA and Western blot (WB) assay. For this purpose, sera samples of 209 trichinellosis patients who were definitely diagnosed during the Trichinella britovi outbreak occurred in İzmir in January 2004, were used. All the samples were screened initially by commercial Toxocara IgG-ELISA kit (Cypress Diagnostics, Belgium), then commercial Toxocara IgG-WB (Test-Line Diagnostics, Czech Republic) was applied to positive/ borderline-positive sera for confirmation. In our study, 94.3% (197/209) of the sera were found seronegative, while nine were positive and three were borderline. Thus a total of 12 (5.7%) sera were considered as seropositive by Toxocara IgG-ELISA. According to the results of WB, only one sera with the antigenic bands of 120 kDa, 32 kDa and 26 kDa in molecular weights was evaluated as positive. Four sera samples were found to be borderline. In three of border sera, the antigenic bands of 120 and 70 kDa in molecular weights were observed together and one sera had three (120, 70 and 32 kDa) different antigenic bands. Seven sera that had been found to be positive by ELISA was considered as negative by WB. While no bands was observed in four of these, three samples had an antigenic band of 120 kDa which had no diagnostic value when it was found alone. The results of our study showed that the crossreactivities between anti-Trichinella antibodies and TES antigens may be observed during Toxocara IgG ELISA assay. For that reason the positive Toxocara IgG-ELISA result should be confirmed by different tests such as WB for the definitive diagnosis of toxocariasis.

  19. Response Latency as a Predictor of the Accuracy of Children's Reports

    ERIC Educational Resources Information Center

    Ackerman, Rakefet; Koriat, Asher

    2011-01-01

    Researchers have explored various diagnostic cues to the accuracy of information provided by child eyewitnesses. Previous studies indicated that children's confidence in their reports predicts the relative accuracy of these reports, and that the confidence-accuracy relationship generally improves as children grow older. In this study, we examined…

  20. Diagnostic accuracy of CTA and MRI/MRA in the evaluation of the cortical venous reflux in the intracranial dural arteriovenous fistula DAVF.

    PubMed

    Lin, Yen-Heng; Wang, Yu-Fen; Liu, Hon-Man; Lee, Chung-Wei; Chen, Ya-Fang; Hsieh, Hong-Jen

    2018-01-01

    Computed tomography angiography (CTA) and magnetic resonance imaging/angiography (MRI/MRA) are used for the diagnosis of intracranial dural arteriovenous fistulas (DAVFs). The purpose of this study was to compare the diagnostic accuracy of CTA and magnetic resonance imaging/angiography (MRI/MRA) for detection of cortical venous reflux (CVR) in intracranial DAVFs. The records of patients with angiography-confirmed intracranial DAVFs who also received CTA and MRI/MRA from January 2008 to July 2016 were reviewed. CTA and MRI/MRA were reviewed for signs of CVR, and the diagnostic accuracy of individual signs was evaluated by receiver operating curve (ROC) analysis. A total 108 patients were included in this study. CTA signs of CVR included abnormal dilatation, early enhancement, and the presence of a medullary or pial vein. MRI/MRA signs of CVR included abnormal dilatation, early enhancement, flow-related enhancement, flow void, and medullary or pial venous collaterals. The sensitivity of individual CTA signs ranged from 62 to 96%, and specificities from 79 to 94%. The sensitivities of individual MRI/MRA signs ranged from 58 to 83%, and specificities from 77 to 93%. The area under ROC curve (AUC) of CTA and MRI/MRA were 0.91 and 0.87, respectively (P = 0.04 in direct comparison). In subgroup analysis, CTA had better diagnostic accuracy for higher grade disease (P = 0.05) and non-aggressive manifestation (P = 0.04). Both CTA and MRI/MRA have good diagnostic accuracy for detection of CVR in patients with intracranial DAVFs. There is modest evidence that CTA is better than MRI/MRA.

  1. Effect of scan quality on diagnostic accuracy of spectral-domain optical coherence tomography in glaucoma.

    PubMed

    Rao, Harsha L; Addepalli, Uday K; Yadav, Ravi K; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2014-03-01

    To evaluate the effect of scan quality on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and ganglion cell complex (GCC) parameters of spectral-domain optical coherence tomography (SD OCT) in glaucoma. Cross-sectional study. Two hundred fifty-two eyes of 183 control subjects (mean deviation [MD]: -1.84 dB) and 207 eyes of 159 glaucoma patients (MD: -7.31 dB) underwent ONH, RNFL, and GCC scanning with SD OCT. Scan quality of SD OCT images was based on signal strength index (SSI) values. Influence of SSI on diagnostic accuracy of SD OCT was evaluated by receiver operating characteristic (ROC) regression. Diagnostic accuracies of all SD OCT parameters were better when the SSI values were higher. This effect was statistically significant (P < .05) for ONH and RNFL but not for GCC parameters. In mild glaucoma (MD of -5 dB), area under ROC curve (AUC) for rim area, average RNFL thickness, and average GCC thickness parameters improved from 0.651, 0.678, and 0.726, respectively, at an SSI value of 30 to 0.873, 0.962, and 0.886, respectively, at an SSI of 70. AUCs of the same parameters in advanced glaucoma (MD of -15 dB) improved from 0.747, 0.890, and 0.873, respectively, at an SSI value of 30 to 0.922, 0.994, and 0.959, respectively, at an SSI of 70. Diagnostic accuracies of SD OCT parameters in glaucoma were significantly influenced by the scan quality even when the SSI values were within the manufacturer-recommended limits. These results should be considered while interpreting the SD OCT scans for glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Recommended reporting standards for test accuracy studies of infectious diseases of finfish, amphibians, molluscs and crustaceans: the STRADAS-aquatic checklist

    USGS Publications Warehouse

    Gardner, Ian A; Whittington, Richard J; Caraguel, Charles G B; Hick, Paul; Moody, Nicholas J G; Corbeil, Serge; Garver, Kyle A.; Warg, Janet V.; Arzul, Isabelle; Purcell, Maureen; St. J. Crane, Mark; Waltzek, Thomas B.; Olesen, Niels J; Lagno, Alicia Gallardo

    2016-01-01

    Complete and transparent reporting of key elements of diagnostic accuracy studies for infectious diseases in cultured and wild aquatic animals benefits end-users of these tests, enabling the rational design of surveillance programs, the assessment of test results from clinical cases and comparisons of diagnostic test performance. Based on deficiencies in the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines identified in a prior finfish study (Gardner et al. 2014), we adapted the Standards for Reporting of Animal Diagnostic Accuracy Studies—paratuberculosis (STRADAS-paraTB) checklist of 25 reporting items to increase their relevance to finfish, amphibians, molluscs, and crustaceans and provided examples and explanations for each item. The checklist, known as STRADAS-aquatic, was developed and refined by an expert group of 14 transdisciplinary scientists with experience in test evaluation studies using field and experimental samples, in operation of reference laboratories for aquatic animal pathogens, and in development of international aquatic animal health policy. The main changes to the STRADAS-paraTB checklist were to nomenclature related to the species, the addition of guidelines for experimental challenge studies, and the designation of some items as relevant only to experimental studies and ante-mortem tests. We believe that adoption of these guidelines will improve reporting of primary studies of test accuracy for aquatic animal diseases and facilitate assessment of their fitness-for-purpose. Given the importance of diagnostic tests to underpin the Sanitary and Phytosanitary agreement of the World Trade Organization, the principles outlined in this paper should be applied to other World Organisation for Animal Health (OIE)-relevant species.

  3. Accuracy of the radioactive copper incorporation test in the diagnosis of Wilson disease.

    PubMed

    Członkowska, Anna; Rodo, Maria; Wierzchowska-Ciok, Agata; Smolinski, Lukasz; Litwin, Tomasz

    2018-02-08

    In Wilson disease (WD), copper accumulates in the liver and other tissues because of mutations in the ATP7B copper transporter gene. Early and effective anticopper treatment is crucial. However, routine diagnostic methods based on clinical findings, copper metabolism tests, liver biopsies and DNA analyses do not always provide a conclusive diagnosis. The aim was to evaluate radioactive copper incorporation as a diagnostic test. We included cases with a diagnosis of WD supported by radiocopper testing and later, when available, confirmed by DNA analysis. Incorporation of 64 Cu was measured at 2, 24 and 48 hours following intravenous injection. Diagnostic accuracy (area under the receiver operating characteristic curve [AUC]), sensitivity, specificity and predictive value were assessed for 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios and compared with serum measurements of ceruloplasmin, copper, non-ceruloplasmin-bound copper and urinary 24-hours copper excretion. Patients having two pathogenic ATP7B mutations (homozygotes/compound heterozygotes) (n = 74) had significantly lower 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios than heterozygote controls (n = 21) (mean 0.14 and 0.12 vs 0.49 and 0.63, respectively; both P < .001). Of note, 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios had excellent diagnostic accuracy, with AUCs approaching 1, and only 24-hours urinary copper excretion displayed similar positive features. Other copper metabolism tests studied had lower accuracy, specificity and sensitivity. The radioactive copper test had excellent diagnostic accuracy and may be useful in the evaluation of new therapies aimed at restoring ATP7B function. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Accuracy of computed tomographic features in differentiating intestinal tuberculosis from Crohn's disease: a systematic review with meta-analysis.

    PubMed

    Kedia, Saurabh; Sharma, Raju; Sreenivas, Vishnubhatla; Madhusudhan, Kumble Seetharama; Sharma, Vishal; Bopanna, Sawan; Pratap Mouli, Venigalla; Dhingra, Rajan; Yadav, Dawesh Prakash; Makharia, Govind; Ahuja, Vineet

    2017-04-01

    Abdominal computed tomography (CT) can noninvasively image the entire gastrointestinal tract and assess extraintestinal features that are important in differentiating Crohn's disease (CD) and intestinal tuberculosis (ITB). The present meta-analysis pooled the results of all studies on the role of CT abdomen in differentiating between CD and ITB. We searched PubMed and Embase for all publications in English that analyzed the features differentiating between CD and ITB on abdominal CT. The features included comb sign, necrotic lymph nodes, asymmetric bowel wall thickening, skip lesions, fibrofatty proliferation, mural stratification, ileocaecal area, long segment, and left colonic involvements. Sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio (DOR) were calculated for all the features. Symmetric receiver operating characteristic curve was plotted for features present in >3 studies. Heterogeneity and publication bias was assessed and sensitivity analysis was performed by excluding studies that compared features on conventional abdominal CT instead of CT enterography (CTE). We included 6 studies (4 CTE, 1 conventional abdominal CT, and 1 CTE+conventional abdominal CT) involving 417 and 195 patients with CD and ITB, respectively. Necrotic lymph nodes had the highest diagnostic accuracy (sensitivity, 23%; specificity, 100%; DOR, 30.2) for ITB diagnosis, and comb sign (sensitivity, 82%; specificity, 81%; DOR, 21.5) followed by skip lesions (sensitivity, 86%; specificity, 74%; DOR, 16.5) had the highest diagnostic accuracy for CD diagnosis. On sensitivity analysis, the diagnostic accuracy of other features excluding asymmetric bowel wall thickening remained similar. Necrotic lymph nodes and comb sign on abdominal CT had the best diagnostic accuracy in differentiating CD and ITB.

  5. Recommended reporting standards for test accuracy studies of infectious diseases of finfish, amphibians, molluscs and crustaceans: the STRADAS-aquatic checklist.

    PubMed

    Gardner, Ian A; Whittington, Richard J; Caraguel, Charles G B; Hick, Paul; Moody, Nicholas J G; Corbeil, Serge; Garver, Kyle A; Warg, Janet V; Arzul, Isabelle; Purcell, Maureen K; Crane, Mark St J; Waltzek, Thomas B; Olesen, Niels J; Gallardo Lagno, Alicia

    2016-02-25

    Complete and transparent reporting of key elements of diagnostic accuracy studies for infectious diseases in cultured and wild aquatic animals benefits end-users of these tests, enabling the rational design of surveillance programs, the assessment of test results from clinical cases and comparisons of diagnostic test performance. Based on deficiencies in the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines identified in a prior finfish study (Gardner et al. 2014), we adapted the Standards for Reporting of Animal Diagnostic Accuracy Studies-paratuberculosis (STRADAS-paraTB) checklist of 25 reporting items to increase their relevance to finfish, amphibians, molluscs, and crustaceans and provided examples and explanations for each item. The checklist, known as STRADAS-aquatic, was developed and refined by an expert group of 14 transdisciplinary scientists with experience in test evaluation studies using field and experimental samples, in operation of reference laboratories for aquatic animal pathogens, and in development of international aquatic animal health policy. The main changes to the STRADAS-paraTB checklist were to nomenclature related to the species, the addition of guidelines for experimental challenge studies, and the designation of some items as relevant only to experimental studies and ante-mortem tests. We believe that adoption of these guidelines will improve reporting of primary studies of test accuracy for aquatic animal diseases and facilitate assessment of their fitness-for-purpose. Given the importance of diagnostic tests to underpin the Sanitary and Phytosanitary agreement of the World Trade Organization, the principles outlined in this paper should be applied to other World Organisation for Animal Health (OIE)-relevant species.

  6. Detection of intracavitary uterine pathology using offline analysis of three-dimensional ultrasound volumes: interobserver agreement and diagnostic accuracy.

    PubMed

    Van den Bosch, T; Valentin, L; Van Schoubroeck, D; Luts, J; Bignardi, T; Condous, G; Epstein, E; Leone, F P; Testa, A C; Van Huffel, S; Bourne, T; Timmerman, D

    2012-10-01

    To estimate the diagnostic accuracy and interobserver agreement in predicting intracavitary uterine pathology at offline analysis of three-dimensional (3D) ultrasound volumes of the uterus. 3D volumes (unenhanced ultrasound and gel infusion sonography with and without power Doppler, i.e. four volumes per patient) of 75 women presenting with abnormal uterine bleeding at a 'bleeding clinic' were assessed offline by six examiners. The sonologists were asked to provide a tentative diagnosis. A histological diagnosis was obtained by hysteroscopy with biopsy or operative hysteroscopy. Proliferative, secretory or atrophic endometrium was classified as 'normal' histology; endometrial polyps, intracavitary myomas, endometrial hyperplasia and endometrial cancer were classified as 'abnormal' histology. The diagnostic accuracy of the six sonologists with regard to normal/abnormal histology and interobserver agreement were estimated. Intracavitary pathology was diagnosed at histology in 39% of patients. Agreement between the ultrasound diagnosis and the histological diagnosis (normal vs abnormal) ranged from 67 to 83% for the six sonologists. In 45% of cases all six examiners agreed with regard to the presence/absence of intracavitary pathology. The percentage agreement between any two examiners ranged from 65 to 91% (Cohen's κ, 0.31-0.81). The Schouten κ for all six examiners was 0.51 (95% CI, 0.40-0.62), while the highest Schouten κ for any three examiners was 0.69. When analyzing stored 3D ultrasound volumes, agreement between sonologists with regard to classifying the endometrium/uterine cavity as normal or abnormal as well as the diagnostic accuracy varied substantially. Possible actions to improve interobserver agreement and diagnostic accuracy include optimization of image quality and the use of a consistent technique for analyzing the 3D volumes. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  7. Comparison of 3T and 7T susceptibility-weighted angiography of the substantia nigra in diagnosing Parkinson disease.

    PubMed

    Cosottini, M; Frosini, D; Pesaresi, I; Donatelli, G; Cecchi, P; Costagli, M; Biagi, L; Ceravolo, R; Bonuccelli, U; Tosetti, M

    2015-03-01

    Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner. Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions. Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T. Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study. © 2015 by American Journal of Neuroradiology.

  8. Additional measures do not improve the diagnostic accuracy of the Hospital Admission Risk Profile for detecting downstream quality of life in community-dwelling older people presenting to a hospital emergency department.

    PubMed

    Grimmer, K; Milanese, S; Beaton, K; Atlas, A

    2014-01-01

    The Hospital Admission Risk Profile (HARP) instrument is commonly used to assess risk of functional decline when older people are admitted to hospital. HARP has moderate diagnostic accuracy (65%) for downstream decreased scores in activities of daily living. This paper reports the diagnostic accuracy of HARP for downstream quality of life. It also tests whether adding other measures to HARP improves its diagnostic accuracy. One hundred and forty-eight independent community dwelling individuals aged 65 years or older were recruited in the emergency department of one large Australian hospital with a medical problem for which they were discharged without a hospital ward admission. Data, including age, sex, primary language, highest level of education, postcode, living status, requiring care for daily activities, using a gait aid, receiving formal community supports, instrumental activities of daily living in the last week, hospitalization and falls in the last 12 months, and mental state were collected at recruitment. HARP scores were derived from a formula that summed scores assigned to age, activities of daily living, and mental state categories. Physical and mental component scores of a quality of life measure were captured by telephone interview at 1 and 3 months after recruitment. HARP scores are moderately accurate at predicting downstream decline in physical quality of life, but did not predict downstream decline in mental quality of life. The addition of other variables to HARP did not improve its diagnostic accuracy for either measure of quality of life. HARP is a poor predictor of quality of life.

  9. A dual tracer (68)Ga-DOTANOC PET/CT and (18)F-FDG PET/CT pilot study for detection of cardiac sarcoidosis.

    PubMed

    Gormsen, Lars C; Haraldsen, Ate; Kramer, Stine; Dias, Andre H; Kim, Won Yong; Borghammer, Per

    2016-12-01

    Cardiac sarcoidosis (CS) is a potentially fatal condition lacking a single test with acceptable diagnostic accuracy. (18)F-FDG PET/CT has emerged as a promising imaging modality, but is challenged by physiological myocardial glucose uptake. An alternative tracer, (68)Ga-DOTANOC, binds to somatostatin receptors on inflammatory cells in sarcoid granulomas. We therefore aimed to conduct a proof-of-concept study using (68)Ga-DOTANOC to diagnose CS. In addition, we compared diagnostic accuracy and inter-observer variability of (68)Ga-DOTANOC vs. (18)F-FDG PET/CT. Nineteen patients (seven female) with suspected CS were prospectively recruited and dual tracer scanned within 7 days. PET images were reviewed by four expert readers for signs of CS and compared to the reference standard (Japanese ministry of Health and Welfare CS criteria). CS was diagnosed in 3/19 patients. By consensus, 11/19 (18)F-FDG scans and 0/19 (68)Ga-DOTANOC scans were rated as inconclusive. The sensitivity of (18)F-FDG PET for diagnosing CS was 33 %, specificity was 88 %, PPV was 33 %, NPV was 88 %, and diagnostic accuracy was 79 %. For (68)Ga-DOTANOC, accuracy was 100 %. Inter-observer agreement was poor for (18)F-FDG PET (Fleiss' combined kappa 0.27, NS) and significantly better for (68)Ga-DOTANOC (Fleiss' combined kappa 0.46, p = 0.001). Despite prolonged pre-scan fasting, a large proportion of (18)F-FDG PET/CT images were rated as inconclusive, resulting in low agreement among reviewers and correspondingly poor diagnostic accuracy. By contrast, (68)Ga-DOTANOC PET/CT had excellent diagnostic accuracy with the caveat that inter-observer variability was still significant. Nevertheless, (68)Ga-DOTANOC PET/CT looks very promising as an alternative CS PET tracer. Current Controlled Trials NCT01729169 .

  10. Diagnostic accuracy of repetition tasks for the identification of specific language impairment (SLI) in bilingual children: evidence from Russian and Hebrew.

    PubMed

    Armon-Lotem, Sharon; Meir, Natalia

    2016-11-01

    Previous research demonstrates that repetition tasks are valuable tools for diagnosing specific language impairment (SLI) in monolingual children in English and a variety of other languages, with non-word repetition (NWR) and sentence repetition (SRep) yielding high levels of sensitivity and specificity. Yet, only a few studies have addressed the diagnostic accuracy of repetition tasks in bilingual children, and most available research focuses on English-Spanish sequential bilinguals. To evaluate the efficacy of three repetition tasks (forward digit span (FWD), NWR and SRep) in order to distinguish mono- and bilingual children with and without SLI in Russian and Hebrew. A total of 230 mono- and bilingual children aged 5;5-6;8 participated in the study: 144 bilingual Russian-Hebrew-speaking children (27 with SLI); and 52 monolingual Hebrew-speaking children (14 with SLI) and 34 monolingual Russian-speaking children (14 with SLI). Parallel repetition tasks were designed in both Russian and Hebrew. Bilingual children were tested in both languages. The findings confirmed that NWR and SRep are valuable tools in distinguishing monolingual children with and without SLI in Russian and Hebrew, while the results for FWD were mixed. Yet, testing of bilingual children with the same tools using monolingual cut-off points resulted in inadequate diagnostic accuracy. We demonstrate, however, that the use of bilingual cut-off points yielded acceptable levels of diagnostic accuracy. The combination of SRep tasks in L1/Russian and L2/Hebrew yielded the highest overall accuracy (i.e., 94%), but even SRep alone in L2/Hebrew showed excellent levels of sensitivity (i.e., 100%) and specificity (i.e., 89%), reaching 91% of total diagnostic accuracy. The results are very promising for identifying SLI in bilingual children and for showing that testing in the majority language with bilingual cut-off points can provide an accurate classification. © 2016 Royal College of Speech and Language Therapists.

  11. Meta-Analyses of Diagnostic Accuracy in Imaging Journals: Analysis of Pooling Techniques and Their Effect on Summary Estimates of Diagnostic Accuracy.

    PubMed

    McGrath, Trevor A; McInnes, Matthew D F; Korevaar, Daniël A; Bossuyt, Patrick M M

    2016-10-01

    Purpose To determine whether authors of systematic reviews of diagnostic accuracy studies published in imaging journals used recommended methods for meta-analysis, and to evaluate the effect of traditional methods on summary estimates of sensitivity and specificity. Materials and Methods Medline was searched for published systematic reviews that included meta-analysis of test accuracy data limited to imaging journals published from January 2005 to May 2015. Two reviewers independently extracted study data and classified methods for meta-analysis as traditional (univariate fixed- or random-effects pooling or summary receiver operating characteristic curve) or recommended (bivariate model or hierarchic summary receiver operating characteristic curve). Use of methods was analyzed for variation with time, geographical location, subspecialty, and journal. Results from reviews in which study authors used traditional univariate pooling methods were recalculated with a bivariate model. Results Three hundred reviews met the inclusion criteria, and in 118 (39%) of those, authors used recommended meta-analysis methods. No change in the method used was observed with time (r = 0.54, P = .09); however, there was geographic (χ(2) = 15.7, P = .001), subspecialty (χ(2) = 46.7, P < .001), and journal (χ(2) = 27.6, P < .001) heterogeneity. Fifty-one univariate random-effects meta-analyses were reanalyzed with the bivariate model; the average change in the summary estimate was -1.4% (P < .001) for sensitivity and -2.5% (P < .001) for specificity. The average change in width of the confidence interval was 7.7% (P < .001) for sensitivity and 9.9% (P ≤ .001) for specificity. Conclusion Recommended methods for meta-analysis of diagnostic accuracy in imaging journals are used in a minority of reviews; this has not changed significantly with time. Traditional (univariate) methods allow overestimation of diagnostic accuracy and provide narrower confidence intervals than do recommended (bivariate) methods. (©) RSNA, 2016 Online supplemental material is available for this article.

  12. The German version of the Posttraumatic Stress Disorder Checklist for DSM-5 (PCL-5): psychometric properties and diagnostic utility.

    PubMed

    Krüger-Gottschalk, Antje; Knaevelsrud, Christine; Rau, Heinrich; Dyer, Anne; Schäfer, Ingo; Schellong, Julia; Ehring, Thomas

    2017-11-28

    The Posttraumatic Stress Disorder (PTSD) Checklist (PCL, now PCL-5) has recently been revised to reflect the new diagnostic criteria of the disorder. A clinical sample of trauma-exposed individuals (N = 352) was assessed with the Clinician Administered PTSD Scale for DSM-5 (CAPS-5) and the PCL-5. Internal consistencies and test-retest reliability were computed. To investigate diagnostic accuracy, we calculated receiver operating curves. Confirmatory factor analyses (CFA) were performed to analyze the structural validity. Results showed high internal consistency (α = .95), high test-retest reliability (r = .91) and a high correlation with the total severity score of the CAPS-5, r = .77. In addition, the recommended cutoff of 33 on the PCL-5 showed high diagnostic accuracy when compared to the diagnosis established by the CAPS-5. CFAs comparing the DSM-5 model with alternative models (the three-factor solution, the dysphoria, anhedonia, externalizing behavior and hybrid model) to account for the structural validity of the PCL-5 remained inconclusive. Overall, the findings show that the German PCL-5 is a reliable instrument with good diagnostic accuracy. However, more research evaluating the underlying factor structure is needed.

  13. Validated methods for identifying tuberculosis patients in health administrative databases: systematic review.

    PubMed

    Ronald, L A; Ling, D I; FitzGerald, J M; Schwartzman, K; Bartlett-Esquilant, G; Boivin, J-F; Benedetti, A; Menzies, D

    2017-05-01

    An increasing number of studies are using health administrative databases for tuberculosis (TB) research. However, there are limitations to using such databases for identifying patients with TB. To summarise validated methods for identifying TB in health administrative databases. We conducted a systematic literature search in two databases (Ovid Medline and Embase, January 1980-January 2016). We limited the search to diagnostic accuracy studies assessing algorithms derived from drug prescription, International Classification of Diseases (ICD) diagnostic code and/or laboratory data for identifying patients with TB in health administrative databases. The search identified 2413 unique citations. Of the 40 full-text articles reviewed, we included 14 in our review. Algorithms and diagnostic accuracy outcomes to identify TB varied widely across studies, with positive predictive value ranging from 1.3% to 100% and sensitivity ranging from 20% to 100%. Diagnostic accuracy measures of algorithms using out-patient, in-patient and/or laboratory data to identify patients with TB in health administrative databases vary widely across studies. Use solely of ICD diagnostic codes to identify TB, particularly when using out-patient records, is likely to lead to incorrect estimates of case numbers, given the current limitations of ICD systems in coding TB.

  14. Teledermatology consultation using a smartphone multimedia messaging service for common skin diseases in the Korean army: a clinical evaluation of its diagnostic accuracy.

    PubMed

    Shin, Hyoseung; Kim, Dong Hyun; Ryu, Hyeong Ho; Yoon, So Young; Jo, Seong Jin

    2014-03-01

    We evaluated the diagnostic accuracy of teleconsultations for skin diseases common in the army using a smartphone multimedia messaging service (MMS). Images of skin lesions were obtained from 100 army patients using digital cameras built into smartphones. Three remotely located dermatologists received the dermatology images and associated clinical information via the MMS. The teledermatologists' diagnoses were compared with those obtained from face-to-face examinations. The three most common diagnoses made at the dermatology clinics were eczema, viral warts and fungal infections. The mean diagnostic agreement between face-to-face and teledermatology consultations was 71% (SD 2). The mean kappa coefficient was 0.73 (SD 0.06) for the three most common diagnostic categories. The mean values for sensitivity were 78% (SD 0), 88% (SD 21) and 61% (SD 11) for eczema, viral warts and fungal infections, respectively, and the specificity values were above 90% for these skin diseases. Teledermatology consultation using smartphones is simple. Although diagnoses using telemedicine do not perfectly match diagnoses from face-to-face consultations the diagnostic accuracy using smartphones is superior to that of clinicians who are not specialized in dermatology.

  15. Stationary intraoral tomosynthesis for dental imaging

    NASA Astrophysics Data System (ADS)

    Inscoe, Christina R.; Wu, Gongting; Soulioti, Danai E.; Platin, Enrique; Mol, Andre; Gaalaas, Laurence R.; Anderson, Michael R.; Tucker, Andrew W.; Boyce, Sarah; Shan, Jing; Gonzales, Brian; Lu, Jianping; Zhou, Otto

    2017-03-01

    Despite recent advances in dental radiography, the diagnostic accuracies for some of the most common dental diseases have not improved significantly, and in some cases remain low. Intraoral x-ray is the most commonly used x-ray diagnostic tool in dental clinics. It however suffers from the typical limitations of a 2D imaging modality including structure overlap. Cone-beam computed tomography (CBCT) uses high radiation dose and suffers from image artifacts and relatively low resolution. The purpose of this study is to investigate the feasibility of developing a stationary intraoral tomosynthesis (s-IOT) using spatially distributed carbon nanotube (CNT) x-ray array technology, and to evaluate its diagnostic accuracy compared to conventional 2D intraoral x-ray. A bench-top s-IOT device was constructed using a linear CNT based X-ray source array and a digital intraoral detector. Image reconstruction was performed using an iterative reconstruction algorithm. Studies were performed to optimize the imaging configuration. For evaluation of s-IOT's diagnostic accuracy, images of a dental quality assurance phantom, and extracted human tooth specimens were acquired. Results show s-IOT increases the diagnostic sensitivity for caries compared to intraoral x-ray at a comparable dose level.

  16. QUADAS and STARD: evaluating the quality of diagnostic accuracy studies.

    PubMed

    Oliveira, Maria Regina Fernandes de; Gomes, Almério de Castro; Toscano, Cristiana Maria

    2011-04-01

    To compare the performance of two approaches, one based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and another on the Standards for Reporting Studies of Diagnostic Accuracy (STARD), in evaluating the quality of studies validating the OptiMal® rapid malaria diagnostic test. Articles validating the rapid test published until 2007 were searched in the Medline/PubMed database. This search retrieved 13 articles. A combination of 12 QUADAS criteria and three STARD criteria were compared with the 12 QUADAS criteria alone. Articles that fulfilled at least 50% of QUADAS criteria were considered as regular to good quality. Of the 13 articles retrieved, 12 fulfilled at least 50% of QUADAS criteria, and only two fulfilled the STARD/QUADAS criteria combined. Considering the two criteria combination (> 6 QUADAS and > 3 STARD), two studies (15.4%) showed good methodological quality. The articles selection using the proposed combination resulted in two to eight articles, depending on the number of items assumed as cutoff point. The STARD/QUADAS combination has the potential to provide greater rigor when evaluating the quality of studies validating malaria diagnostic tests, given that it incorporates relevant information not contemplated in the QUADAS criteria alone.

  17. Diagnostic Accuracy of Cone-beam Computed Tomography and Conventional Radiography on Apical Periodontitis: A Systematic Review and Meta-analysis.

    PubMed

    Leonardi Dutra, Kamile; Haas, Letícia; Porporatti, André Luís; Flores-Mir, Carlos; Nascimento Santos, Juliana; Mezzomo, Luis André; Corrêa, Márcio; De Luca Canto, Graziela

    2016-03-01

    Endodontic diagnosis depends on accurate radiographic examination. Assessment of the location and extent of apical periodontitis (AP) can influence treatment planning and subsequent treatment outcomes. Therefore, this systematic review and meta-analysis assessed the diagnostic accuracy of conventional radiography and cone-beam computed tomographic (CBCT) imaging on the discrimination of AP from no lesion. Eight electronic databases with no language or time limitations were searched. Articles in which the primary objective was to evaluate the accuracy (sensitivity and specificity) of any type of radiographic technique to assess AP in humans were selected. The gold standard was the histologic examination for actual AP (in vivo) or in situ visualization of bone defects for induced artificial AP (in vitro). Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v.5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark) and MetaDisc v.1.4. software (Unit of Clinical Biostatistics Team of the Ramón y Cajal Hospital, Madrid, Spain). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. Only 9 studies met the inclusion criteria and were subjected to a qualitative analysis. A meta-analysis was conducted on 6 of these articles. All of these articles studied artificial AP with induced bone defects. The accuracy values (area under the curve) were 0.96 for CBCT imaging, 0.73 for conventional periapical radiography, and 0.72 for digital periapical radiography. No evidence was found for panoramic radiography. Periapical radiographs (digital and conventional) reported good diagnostic accuracy on the discrimination of artificial AP from no lesions, whereas CBCT imaging showed excellent accuracy values. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  18. Sensitive determination of dopamine levels via surface-enhanced Raman scattering of Ag nanoparticle dimers.

    PubMed

    Yu, Xiantong; He, XiaoXiao; Yang, Taiqun; Zhao, Litao; Chen, Qichen; Zhang, Sanjun; Chen, Jinquan; Xu, Jianhua

    2018-01-01

    Dopamine (DA) is an important neurotransmitter in the hypothalamus and pituitary gland, which can produce a direct influence on mammals' emotions in midbrain. Additionally, the level of DA is highly related with some important neurologic diseases such as schizophrenia, Parkinson, and Huntington's diseases, etc. In light of the important roles that DA plays in the disease modulation, it is of considerable significance to develop a sensitive and reproducible approach for monitoring DA. The objective of this study was to develop an efficient approach to quantitatively monitor the level of DA using Ag nanoparticle (NP) dimers and enhanced Raman spectroscopy. Ag NP dimers were synthesized for the sensitive detection of DA via surface-enhanced Raman scattering (SERS). Citrate was used as both the capping agent of NPs and sensing agent to DA, which is self-assembled on the surface of Ag NP dimers by reacting with the surface carboxyl group to form a stable amide bond. To improve accuracy and precision, the multiplicative effects model for surface-enhanced Raman spectroscopy was utilized to analyze the SERS assays. A low limits of detection (LOD) of 20 pM and a wide linear response range from 30 pM to 300 nM were obtained for DA quantitative detection. The SERS enhancement factor was theoretically valued at approximately 10 7 by discrete dipole approximation. DA was self-assembled on the citrate capped surface of Ag NPs dimers through the amide bond. The adsorption energy was estimated to be 256 KJ/mol using the Langmuir isotherm model. The density functional theory was used to simulate the spectral characteristics of SERS during the adsorption of DA on the surface of the Ag dimers. Furthermore, to improve the accuracy and precision of quantitative analysis of SERS assays with a multiplicative effects model for surface-enhanced Raman spectroscopy. A LOD of 20 pM DA-level was obtained, and the linear response ranged from 30 pM to 300 nM for quantitative DA detection. The absolute relative percentage error was 4.22% between the real and predicted DA concentrations. This detection scheme is expected to have good applications in the prevention and diagnosis of certain diseases caused by disorders in the DA level.

  19. Sensitive determination of dopamine levels via surface-enhanced Raman scattering of Ag nanoparticle dimers

    PubMed Central

    Yu, Xiantong; He, XiaoXiao; Yang, Taiqun; Zhao, Litao; Chen, Qichen; Zhang, Sanjun; Chen, Jinquan; Xu, Jianhua

    2018-01-01

    Background Dopamine (DA) is an important neurotransmitter in the hypothalamus and pituitary gland, which can produce a direct influence on mammals’ emotions in midbrain. Additionally, the level of DA is highly related with some important neurologic diseases such as schizophrenia, Parkinson, and Huntington’s diseases, etc. In light of the important roles that DA plays in the disease modulation, it is of considerable significance to develop a sensitive and reproducible approach for monitoring DA. Purpose The objective of this study was to develop an efficient approach to quantitatively monitor the level of DA using Ag nanoparticle (NP) dimers and enhanced Raman spectroscopy. Methods Ag NP dimers were synthesized for the sensitive detection of DA via surface-enhanced Raman scattering (SERS). Citrate was used as both the capping agent of NPs and sensing agent to DA, which is self-assembled on the surface of Ag NP dimers by reacting with the surface carboxyl group to form a stable amide bond. To improve accuracy and precision, the multiplicative effects model for surface-enhanced Raman spectroscopy was utilized to analyze the SERS assays. Results A low limits of detection (LOD) of 20 pM and a wide linear response range from 30 pM to 300 nM were obtained for DA quantitative detection. The SERS enhancement factor was theoretically valued at approximately 107 by discrete dipole approximation. DA was self-assembled on the citrate capped surface of Ag NPs dimers through the amide bond. The adsorption energy was estimated to be 256 KJ/mol using the Langmuir isotherm model. The density functional theory was used to simulate the spectral characteristics of SERS during the adsorption of DA on the surface of the Ag dimers. Furthermore, to improve the accuracy and precision of quantitative analysis of SERS assays with a multiplicative effects model for surface-enhanced Raman spectroscopy. Conclusion A LOD of 20 pM DA-level was obtained, and the linear response ranged from 30 pM to 300 nM for quantitative DA detection. The absolute relative percentage error was 4.22% between the real and predicted DA concentrations. This detection scheme is expected to have good applications in the prevention and diagnosis of certain diseases caused by disorders in the DA level. PMID:29713165

  20. [Development of the lung cancer diagnostic system].

    PubMed

    Lv, You-Jiang; Yu, Shou-Yi

    2009-07-01

    To develop a lung cancer diagnosis system. A retrospective analysis was conducted in 1883 patients with primary lung cancer or benign pulmonary diseases (pneumonia, tuberculosis, or pneumonia pseudotumor). SPSS11.5 software was used for data processing. For the relevant factors, a non-factor Logistic regression analysis was used followed by establishment of the regression model. Microsoft Visual Studio 2005 system development platform and VB.Net corresponding language were used to develop the lung cancer diagnosis system. The non-factor multi-factor regression model showed a goodness-of-fit (R2) of the model of 0.806, with a diagnostic accuracy for benign lung diseases of 92.8%, a diagnostic accuracy for lung cancer of 89.0%, and an overall accuracy of 90.8%. The model system for early clinical diagnosis of lung cancer has been established.

  1. Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy.

    PubMed

    Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum

    2017-01-01

    The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Retrospective study. Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% ( P < 0.0001); specificity, 98.53% and 86.76% ( P = 0.0026); accuracy, 77.04% and 85.93% ( P = 0.0423), respectively. The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test.

  2. Accuracy of ultra-wide-field fundus ophthalmoscopy-assisted deep learning, a machine-learning technology, for detecting age-related macular degeneration.

    PubMed

    Matsuba, Shinji; Tabuchi, Hitoshi; Ohsugi, Hideharu; Enno, Hiroki; Ishitobi, Naofumi; Masumoto, Hiroki; Kiuchi, Yoshiaki

    2018-05-09

    To predict exudative age-related macular degeneration (AMD), we combined a deep convolutional neural network (DCNN), a machine-learning algorithm, with Optos, an ultra-wide-field fundus imaging system. First, to evaluate the diagnostic accuracy of DCNN, 364 photographic images (AMD: 137) were amplified and the area under the curve (AUC), sensitivity and specificity were examined. Furthermore, in order to compare the diagnostic abilities between DCNN and six ophthalmologists, we prepared yield 84 sheets comprising 50% of normal and wet-AMD data each, and calculated the correct answer rate, specificity, sensitivity, and response times. DCNN exhibited 100% sensitivity and 97.31% specificity for wet-AMD images, with an average AUC of 99.76%. Moreover, comparing the diagnostic abilities of DCNN versus six ophthalmologists, the average accuracy of the DCNN was 100%. On the other hand, the accuracy of ophthalmologists, determined only by Optos images without a fundus examination, was 81.9%. A combination of DCNN with Optos images is not better than a medical examination; however, it can identify exudative AMD with a high level of accuracy. Our system is considered useful for screening and telemedicine.

  3. Accuracy of Four Imaging Techniques for Diagnosis of Posterior Pelvic Floor Disorders.

    PubMed

    van Gruting, Isabelle M A; Stankiewicz, Aleksandra; Kluivers, Kirsten; De Bin, Riccardo; Blake, Helena; Sultan, Abdul H; Thakar, Ranee

    2017-11-01

    To establish the diagnostic test accuracy of evacuation proctography, magnetic resonance imaging (MRI), transperineal ultrasonography, and endovaginal ultrasonography for detecting posterior pelvic floor disorders (rectocele, enterocele, intussusception, and anismus) in women with obstructed defecation syndrome and secondarily to identify the most patient-friendly imaging technique. In this prospective cohort study, 131 women with symptoms of obstructed defecation syndrome underwent evacuation proctogram, MRI, and transperineal and endovaginal ultrasonography. Images were analyzed by two blinded observers. In the absence of a reference standard, latent class analysis was used to assess diagnostic test accuracy of multiple tests with area under the curve (AUC) as the primary outcome measure. Secondary outcome measures were interobserver agreement calculated as Cohen's κ and patient acceptability using a visual analog scale. No significant differences in diagnostic accuracy were found among the imaging techniques for all the target conditions. Estimates of diagnostic test accuracy were highest for rectocele using MRI (AUC 0.79) or transperineal ultrasonography (AUC 0.85), for enterocele using transperineal (AUC 0.73) or endovaginal ultrasonography (AUC 0.87), for intussusception using evacuation proctography (AUC 0.76) or endovaginal ultrasonography (AUC 0.77), and for anismus using endovaginal (AUC 0.95) or transperineal ultrasonography (AUC 0.78). Interobserver agreement for the diagnosis of rectocele (κ 0.53-0.72), enterocele (κ 0.54-0.94) and anismus (κ 0.43-0.81) was moderate to excellent, but poor to fair for intussusception (κ -0.03 to 0.37) with all techniques. Patient acceptability was better for transperineal and endovaginal ultrasonography as compared with MRI and evacuation proctography (P<.001). Evacuation proctography, MRI, and transperineal and endovaginal ultrasonography were shown to have similar diagnostic test accuracy. Evacuation proctography is not the best available imaging technique. There is no one optimal test for the diagnosis of all posterior pelvic floor disorders. Because transperineal and endovaginal ultrasonography have good test accuracy and patient acceptability, we suggest these could be used for initial assessment of obstructed defecation syndrome. ClinicalTrials.gov, NCT02239302.

  4. Comparison of dermatoscopic diagnostic algorithms based on calculation: The ABCD rule of dermatoscopy, the seven-point checklist, the three-point checklist and the CASH algorithm in dermatoscopic evaluation of melanocytic lesions.

    PubMed

    Unlu, Ezgi; Akay, Bengu N; Erdem, Cengizhan

    2014-07-01

    Dermatoscopic analysis of melanocytic lesions using the CASH algorithm has rarely been described in the literature. The purpose of this study was to compare the sensitivity, specificity, and diagnostic accuracy rates of the ABCD rule of dermatoscopy, the seven-point checklist, the three-point checklist, and the CASH algorithm in the diagnosis and dermatoscopic evaluation of melanocytic lesions on the hairy skin. One hundred and fifteen melanocytic lesions of 115 patients were examined retrospectively using dermatoscopic images and compared with the histopathologic diagnosis. Four dermatoscopic algorithms were carried out for all lesions. The ABCD rule of dermatoscopy showed sensitivity of 91.6%, specificity of 60.4%, and diagnostic accuracy of 66.9%. The seven-point checklist showed sensitivity, specificity, and diagnostic accuracy of 87.5, 65.9, and 70.4%, respectively; the three-point checklist 79.1, 62.6, 66%; and the CASH algorithm 91.6, 64.8, and 70.4%, respectively. To our knowledge, this is the first study that compares the sensitivity, specificity and diagnostic accuracy of the ABCD rule of dermatoscopy, the three-point checklist, the seven-point checklist, and the CASH algorithm for the diagnosis of melanocytic lesions on the hairy skin. In our study, the ABCD rule of dermatoscopy and the CASH algorithm showed the highest sensitivity for the diagnosis of melanoma. © 2014 Japanese Dermatological Association.

  5. Diagnostic accuracy for major depression in multiple sclerosis using self-report questionnaires.

    PubMed

    Fischer, Anja; Fischer, Marcus; Nicholls, Robert A; Lau, Stephanie; Poettgen, Jana; Patas, Kostas; Heesen, Christoph; Gold, Stefan M

    2015-09-01

    Multiple sclerosis and major depressive disorder frequently co-occur but depression often remains undiagnosed in this population. Self-rated depression questionnaires are a good option where clinician-based standardized diagnostics are not feasible. However, there is a paucity of data on diagnostic accuracy of self-report measures for depression in multiple sclerosis (MS). Moreover, head-to-head comparisons of common questionnaires are largely lacking. This could be particularly relevant for high-risk patients with depressive symptoms. Here, we compare the diagnostic accuracy of the Beck Depression Inventory (BDI) and 30-item version of the Inventory of Depressive Symptomatology Self-Rated (IDS-SR30) for major depressive disorder (MSS) against diagnosis by a structured clinical interview. Patients reporting depressive symptoms completed the BDI, the IDS-SR30 and underwent diagnostic assessment (Mini International Neuropsychiatric Interview, M.I.N.I.). Receiver-Operating Characteristic analyses were performed, providing error estimates and false-positive/negative rates of suggested thresholds. Data from n = 31 MS patients were available. BDI and IDS-SR30 total score were significantly correlated (r = 0.82). The IDS-SR30total score, cognitive subscore, and BDI showed excellent to good accuracy (area under the curve (AUC) 0.86, 0.91, and 0.85, respectively). Both the IDS-SR30 and the BDI are useful to quantify depressive symptoms showing good sensitivity and specificity. The IDS-SR30 cognitive subscale may be useful as a screening tool and to quantify affective/cognitive depressive symptomatology.

  6. A systematic review of the sensitivity and specificity of the toe-brachial index for detecting peripheral artery disease.

    PubMed

    Tehan, Peta Ellen; Santos, Derek; Chuter, Vivienne Helaine

    2016-08-01

    The toe-brachial index (TBI) is used as an adjunct to the ankle-brachial index (ABI) for non-invasive lower limb vascular screening. With increasing evidence suggesting limitations of the ABI for diagnosis of vascular complications, particularly in specific populations including diabetes cohorts, the TBI is being used more widely. The aim of this review was to determine the sensitivity and specificity of the TBI for detecting peripheral artery disease (PAD) in populations at risk of this disease. A database search was conducted to identify current work relating to the sensitivity and specificity of toe-brachial indices up to July 2015. Only studies using valid diagnostic imaging as a reference standard were included. The QUADAS-2 tool was used to critically appraise included articles. Seven studies met the inclusion criteria. Sensitivity of the TBI for PAD was reported in all seven studies and ranged from 45% to 100%; specificity was reported by five studies only and ranged from 16% to 100%. In conclusion, this review suggests that the TBI has variable diagnostic accuracy for the presence of PAD in specific populations at risk of developing the disease. There was a notable lack of large-scale diagnostic accuracy studies determining the diagnostic accuracy of the TBI in detecting PAD in different at-risk cohorts. However, standardised normal values need to be established for the TBI to conclusively determine the diagnostic accuracy of this test. © The Author(s) 2016.

  7. A Brief Report of the Diagnostic Accuracy of Oral Reading Fluency and Reading Inventory Levels for Reading Failure Risk among Second- and Third-Grade Students

    ERIC Educational Resources Information Center

    Parker, David C.; Zaslofsky, Anne F.; Burns, Matthew K.; Kanive, Rebecca; Hodgson, Jennifer; Scholin, Sarah E.; Klingbeil, David A.

    2015-01-01

    The availability of psychometrically sound and usable universal screeners is a key component to successful early identification within a response-to-intervention model. The purpose of this study was to compare the diagnostic accuracy of oral reading fluency (ORF) and an informal reading inventory for identifying students considered at risk for…

  8. Dynamic assessment of narrative ability in English accurately identifies language impairment in English language learners.

    PubMed

    Peña, Elizabeth D; Gillam, Ronald B; Bedore, Lisa M

    2014-12-01

    To assess the identification accuracy of dynamic assessment (DA) of narrative ability in English for children learning English as a 2nd language. A DA task was administered to 54 children: 18 Spanish-English-speaking children with language impairment (LI); 18 age-, sex-, IQ- and language experience-matched typical control children; and an additional 18 age- and language experience-matched comparison children. A variety of quantitative and qualitative measures were collected in the pretest phase, the mediation phase, and the posttest phase of the study. Exploratory discriminant analysis was used to determine the set of measures that best differentiated among this group of children with and without LI. A combination of examiner ratings of modifiability (compliance, metacognition, and task orientation), DA story scores (setting, dialogue, and complexity of vocabulary), and ungrammaticality (derived from the posttest narrative sample) classified children with 80.6% to 97.2% accuracy. DA conducted in English provides a systematic means for measuring learning processes and learning outcomes, resulting in a clinically useful procedure for identifying LIs in bilingual children who are in the process of learning English as a second language.

  9. The methodological quality of diagnostic test accuracy studies for musculoskeletal conditions can be improved.

    PubMed

    Henschke, Nicholas; Keuerleber, Julia; Ferreira, Manuela; Maher, Christopher G; Verhagen, Arianne P

    2014-04-01

    To provide an overview of reporting and methodological quality in diagnostic test accuracy (DTA) studies in the musculoskeletal field and evaluate the use of the QUality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist. A literature review identified all systematic reviews that evaluated the accuracy of clinical tests to diagnose musculoskeletal conditions and used the QUADAS checklist. Two authors screened all identified reviews and extracted data on the target condition, index tests, reference standard, included studies, and QUADAS items. A descriptive analysis of the QUADAS checklist was performed, along with Rasch analysis to examine the construct validity and internal reliability. A total of 19 systematic reviews were included, which provided data on individual items of the QUADAS checklist for 392 DTA studies. In the musculoskeletal field, uninterpretable or intermediate test results are commonly not reported, with 175 (45%) studies scoring "no" to this item. The proportion of studies fulfilling certain items varied from 22% (item 11) to 91% (item 3). The interrater reliability of the QUADAS checklist was good and Rasch analysis showed excellent construct validity and internal consistency. This overview identified areas where the reporting and performance of diagnostic studies within the musculoskeletal field can be improved. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. How to tell a patient's story? Influence of the case narrative design on the clinical reasoning process in virtual patients.

    PubMed

    Hege, Inga; Dietl, Anita; Kiesewetter, Jan; Schelling, Jörg; Kiesewetter, Isabel

    2018-02-28

    Virtual patients (VPs) are narrative-based educational activities to train clinical reasoning in a safe environment. Our aim was to explore the influence of the design of the narrative and level of difficulty on the clinical reasoning process, diagnostic accuracy and time-on-task. In a randomized controlled trial, we analyzed the clinical reasoning process of 46 medical students with six VPs in three different variations: (1) patients showing a friendly behavior, (2) patients showing a disruptive behavior and (3) a version without a patient story. For easy VPs, we did not see a significant difference in diagnostic accuracy. For difficult VPs, the diagnostic accuracy was significantly higher for participants who worked on the friendly VPs compared to the other two groups. Independent from VP difficulty, participants identified significantly more problems and tests for disruptive than for friendly VPs; time on task was comparable for these two groups. The extrinsic motivation of participants working on the VPs without a patient story was significantly lower than for the students working on the friendly VPs. Our results indicate that the measured VP difficulty has a higher influence on the clinical reasoning process and diagnostic accuracy than the variations in the narratives.

  11. Individual Patient Diagnosis of AD and FTD via High-Dimensional Pattern Classification of MRI

    PubMed Central

    Davatzikos, C.; Resnick, S. M.; Wu, X.; Parmpi, P.; Clark, C. M.

    2008-01-01

    The purpose of this study is to determine the diagnostic accuracy of MRI-based high-dimensional pattern classification in differentiating between patients with Alzheimer’s Disease (AD), Frontotemporal Dementia (FTD), and healthy controls, on an individual patient basis. MRI scans of 37 patients with AD and 37 age-matched cognitively normal elderly individuals, as well as 12 patients with FTD and 12 age-matched cognitively normal elderly individuals, were analyzed using voxel-based analysis and high-dimensional pattern classification. Diagnostic sensitivity and specificity of spatial patterns of regional brain atrophy found to be characteristic of AD and FTD were determined via cross-validation and via split-sample methods. Complex spatial patterns of relatively reduced brain volumes were identified, including temporal, orbitofrontal, parietal and cingulate regions, which were predominantly characteristic of either AD or FTD. These patterns provided 100% diagnostic accuracy, when used to separate AD or FTD from healthy controls. The ability to correctly distinguish AD from FTD averaged 84.3%. All estimates of diagnostic accuracy were determined via cross-validation. In conclusion, AD- and FTD-specific patterns of brain atrophy can be detected with high accuracy using high-dimensional pattern classification of MRI scans obtained in a typical clinical setting. PMID:18474436

  12. Displaying chest X-ray by beamer or monitor: comparison of diagnostic accuracy for subtle abnormalities.

    PubMed

    Kuiper, L M; Thijs, A; Smulders, Y M

    2012-01-01

    The advent of beamer projection of radiological images raises the issue of whether such projection compromises diagnostic accuracy. The purpose of this study was to evaluate whether beamer projection of chest X-rays is inferior to monitor display. We selected 53 chest X-rays with subtle abnormalities and 15 normal X-rays. The images were independently judged by a senior radiologist and a senior pulmonologist with a state-of-art computer monitor. We used their unanimous or consensus judgment as the reference test. Subsequently, four observers (one senior pulmonologist, one senior radiologist and one resident from each speciality) judged these X-rays on a standard clinical computer monitor and with beamer projection. We compared the number of correct results for each method. Overall, the sensitivity and specificity did not differ between monitor and beamer projection. Separate analyses in senior and junior examiners suggested that senior examiners had a moderate loss of diagnostic accuracy (8% lower sensitivity, pp<0.05, and 6% lower specificity, p=ns) associated with the use of beamer projection, whereas juniors showed similar performance on both imaging modalities. These initial data suggest that beamer projection may be associated with a small loss of diagnostic accuracy in specific subgroups of physicians. This finding illustrates the need for more extensive studies.

  13. Discovery of putative salivary biomarkers for Sjögren's syndrome using high resolution mass spectrometry and bioinformatics.

    PubMed

    Zoukhri, Driss; Rawe, Ian; Singh, Mabi; Brown, Ashley; Kublin, Claire L; Dawson, Kevin; Haddon, William F; White, Earl L; Hanley, Kathleen M; Tusé, Daniel; Malyj, Wasyl; Papas, Athena

    2012-03-01

    The purpose of the current study was to determine if saliva contains biomarkers that can be used as diagnostic tools for Sjögren's syndrome (SjS). Twenty seven SjS patients and 27 age-matched healthy controls were recruited for these studies. Unstimulated glandular saliva was collected from the Wharton's duct using a suction device. Two µl of salvia were processed for mass spectrometry analyses on a prOTOF 2000 matrix-assisted laser desorption/ionization orthogonal time of flight (MALDI O-TOF) mass spectrometer. Raw data were analyzed using bioinformatic tools to identify biomarkers. MALDI O-TOF MS analyses of saliva samples were highly reproducible and the mass spectra generated were very rich in peptides and peptide fragments in the 750-7,500 Da range. Data analysis using bioinformatic tools resulted in several classification models being built and several biomarkers identified. One model based on 7 putative biomarkers yielded a sensitivity of 97.5%, specificity of 97.8% and an accuracy of 97.6%. One biomarker was present only in SjS samples and was identified as a proteolytic peptide originating from human basic salivary proline-rich protein 3 precursor. We conclude that salivary biomarkers detected by high-resolution mass spectrometry coupled with powerful bioinformatic tools offer the potential to serve as diagnostic/prognostic tools for SjS.

  14. Squash preparation: A reliable diagnostic tool in the intraoperative diagnosis of central nervous system tumors

    PubMed Central

    Mitra, Sumit; Kumar, Mohan; Sharma, Vivek; Mukhopadhyay, Debasis

    2010-01-01

    Background: Intraoperative cytology is an important diagnostic modality improving on the accuracy of the frozen sections. It has shown to play an important role especially in the intraoperative diagnosis of central nervous system tumors. Aim: To study the diagnostic accuracy of squash preparation and frozen section (FS) in the intraoperative diagnosis of central nervous system (CNS) tumors. Materials and Methods: This prospective study of 114 patients with CNS tumors was conducted over a period of 18 months (September 2004 to February 2006). The cytological preparations were stained by the quick Papanicolaou method. The squash interpretation and FS diagnosis were later compared with the paraffin section diagnosis. Results: Of the 114 patients, cytological diagnosis was offered in 96 cases. Eighteen nonneoplastic or noncontributory cases were excluded. Using hematoxylin and eosin-stained histopathology sections as the gold standard, the diagnostic accuracy of cytology was 88.5% (85/96) and the accuracy on FS diagnosis was 90.6% (87/96). Among these cases, gliomas formed the largest category of tumors (55.2%). The cytological accuracy in this group was 84.9% (45/53) and the comparative FS figure was 86.8% (46/53). In cases where the smear and the FS diagnosis did not match, the latter opinion was offered. Conclusions: Squash preparation is a reliable, rapid and easy method and can be used as a complement to FS in the intraoperative diagnosis of CNS tumors. PMID:21187881

  15. Diagnostic Classification of Schizophrenia Patients on the Basis of Regional Reward-Related fMRI Signal Patterns

    PubMed Central

    Koch, Stefan P.; Hägele, Claudia; Haynes, John-Dylan; Heinz, Andreas; Schlagenhauf, Florian; Sterzer, Philipp

    2015-01-01

    Functional neuroimaging has provided evidence for altered function of mesolimbic circuits implicated in reward processing, first and foremost the ventral striatum, in patients with schizophrenia. While such findings based on significant group differences in brain activations can provide important insights into the pathomechanisms of mental disorders, the use of neuroimaging results from standard univariate statistical analysis for individual diagnosis has proven difficult. In this proof of concept study, we tested whether the predictive accuracy for the diagnostic classification of schizophrenia patients vs. healthy controls could be improved using multivariate pattern analysis (MVPA) of regional functional magnetic resonance imaging (fMRI) activation patterns for the anticipation of monetary reward. With a searchlight MVPA approach using support vector machine classification, we found that the diagnostic category could be predicted from local activation patterns in frontal, temporal, occipital and midbrain regions, with a maximal cluster peak classification accuracy of 93% for the right pallidum. Region-of-interest based MVPA for the ventral striatum achieved a maximal cluster peak accuracy of 88%, whereas the classification accuracy on the basis of standard univariate analysis reached only 75%. Moreover, using support vector regression we could additionally predict the severity of negative symptoms from ventral striatal activation patterns. These results show that MVPA can be used to substantially increase the accuracy of diagnostic classification on the basis of task-related fMRI signal patterns in a regionally specific way. PMID:25799236

  16. Diagnostic accuracy of physical examination for anterior knee instability: a systematic review.

    PubMed

    Leblanc, Marie-Claude; Kowalczuk, Marcin; Andruszkiewicz, Nicole; Simunovic, Nicole; Farrokhyar, Forough; Turnbull, Travis Lee; Debski, Richard E; Ayeni, Olufemi R

    2015-10-01

    Determining diagnostic accuracy of Lachman, pivot shift and anterior drawer tests versus gold standard diagnosis (magnetic resonance imaging or arthroscopy) for anterior cruciate ligament (ACL) insufficiency cases. Secondarily, evaluating effects of: chronicity, partial rupture, awake versus anaesthetized evaluation. Searching MEDLINE, EMBASE and PubMed identified studies on diagnostic accuracy for ACL insufficiency. Studies identification and data extraction were performed in duplicate. Quality assessment used QUADAS tool, and statistical analyses were completed for pooled sensitivity and specificity. Eight studies were included. Given insufficient data, pooled analysis was only possible for sensitivity on Lachman and pivot shift test. During awake evaluation, sensitivity for the Lachman test was 89 % (95 % CI 0.76, 0.98) for all rupture types, 96 % (95 % CI 0.90, 1.00) for complete ruptures and 68 % (95 % CI 0.25, 0.98) for partial ruptures. For pivot shift in awake evaluation, results were 79 % (95 % CI 0.63, 0.91) for all rupture types, 86 % (95 % CI 0.68, 0.99) for complete ruptures and 67 % (95 % CI 0.47, 0.83) for partial ruptures. Decreased sensitivity of Lachman and pivot shift tests for partial rupture cases and for awake patients raised suspicions regarding the accuracy of these tests for diagnosis of ACL insufficiency. This may lead to further research aiming to improve the understanding of the true accuracy of these physical diagnostic tests and increase the reliability of clinical investigation for this pathology. IV.

  17. TMS combined with EEG in genetic generalized epilepsy: A phase II diagnostic accuracy study.

    PubMed

    Kimiskidis, Vasilios K; Tsimpiris, Alkiviadis; Ryvlin, Philippe; Kalviainen, Reetta; Koutroumanidis, Michalis; Valentin, Antonio; Laskaris, Nikolaos; Kugiumtzis, Dimitris

    2017-02-01

    (A) To develop a TMS-EEG stimulation and data analysis protocol in genetic generalized epilepsy (GGE). (B) To investigate the diagnostic accuracy of TMS-EEG in GGE. Pilot experiments resulted in the development and optimization of a paired-pulse TMS-EEG protocol at rest, during hyperventilation (HV), and post-HV combined with multi-level data analysis. This protocol was applied in 11 controls (C) and 25 GGE patients (P), further dichotomized into responders to antiepileptic drugs (R, n=13) and non-responders (n-R, n=12).Features (n=57) extracted from TMS-EEG responses after multi-level analysis were given to a feature selection scheme and a Bayesian classifier, and the accuracy of assigning participants into the classes P-C and R-nR was computed. On the basis of the optimal feature subset, the cross-validated accuracy of TMS-EEG for the classification P-C was 0.86 at rest, 0.81 during HV and 0.92 at post-HV, whereas for R-nR the corresponding figures are 0.80, 0.78 and 0.65, respectively. Applying a fusion approach on all conditions resulted in an accuracy of 0.84 for the classification P-C and 0.76 for the classification R-nR. TMS-EEG can be used for diagnostic purposes and for assessing the response to antiepileptic drugs. TMS-EEG holds significant diagnostic potential in GGE. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  18. Accuracy of giant African pouched rats for diagnosing tuberculosis: comparison with culture and Xpert® MTB/RIF.

    PubMed

    Mulder, C; Mgode, G F; Ellis, H; Valverde, E; Beyene, N; Cox, C; Reid, S E; Van't Hoog, A H; Edwards, T L

    2017-11-01

    Enhanced tuberculosis (TB) case finding using detection rats in Tanzania. To assess the diagnostic accuracy of detection rats compared with culture and Xpert® MTB/RIF, and to compare enhanced case-finding algorithms using rats in smear-negative presumptive TB patients. A fully paired diagnostic accuracy study in which sputum of new adult presumptive TB patients in Tanzania was tested using smear microscopy, 11 detection rats, culture and Xpert. Of 771 eligible participants, 345 (45%) were culture-positive for Mycobacterium tuberculosis, and 264 (34%) were human immunodeficiency virus (HIV) positive. The sensitivity of the detection rats was up to 75.1% (95%CI 70.1-79.5) when compared with culture, and up to 81.8% (95%CI 76.0-86.5) when compared with Xpert, which was statistically significantly higher than the sensitivity of smear microscopy. Corresponding specificity was 40.6% (95%CI 35.9-45.5) compared with culture. The accuracy of rat detection was independent of HIV status. Using rats for triage, followed by Xpert, would result in a statistically higher yield than rats followed by light-emitting diode fluorescence microscopy, whereas the number of false-positives would be significantly lower than when using Xpert alone. Although detection rats did not meet the accuracy criteria as standalone diagnostic or triage testing for presumptive TB, they have additive value as a triage test for enhanced case finding among smear-negative TB patients if more advanced diagnostics are not available.

  19. Diagnostic performance of semi-quantitative and quantitative stress CMR perfusion analysis: a meta-analysis.

    PubMed

    van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M

    2017-11-27

    Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory analysis our results show similar diagnostic accuracy comparing anatomical (AUC 0.86(0.83-0.89)) and functional reference standards (AUC 0.88(0.84-0.90)). Only the per territory analysis sensitivity did not show significant heterogeneity. None of the groups showed signs of publication bias. The clinical value of semi-quantitative and quantitative CMR perfusion analysis remains uncertain due to extensive inter-study heterogeneity and large differences in CMR perfusion acquisition protocols, reference standards, and methods of assessment of myocardial perfusion parameters. For wide spread implementation, standardization of CMR perfusion techniques is essential. CRD42016040176 .

  20. Accuracy of radiographic caries diagnosis using different X-ray generators.

    PubMed

    Svenson, B; Petersson, A

    1989-05-01

    Dental X-ray machines utilizing five different combinations of X-ray generators and tube voltages (Philips Oralix 65 kV, Siemens Heliodent EC 60 kV, Siemens Heliodent 70 kV, Soredex Minray DC 60 kV and Soredex Minray DC 70 kV) were compared with respect to the accuracy of radiographic diagnosis of proximal caries. Nine observers diagnosed proximal caries in radiographs of extracted premolars. The findings of the observers were compared to the actual presence or absence of caries. The ROC-curve technique was used to evaluate differences in diagnostic accuracy between the X-ray machines. The results showed small differences in diagnostic accuracy between the different X-ray generators but they proved to be statistically non-significant.

  1. How to: evaluate a diagnostic test.

    PubMed

    Leeflang, Mariska M G; Allerberger, Franz

    2018-06-12

    The development of an in vitro diagnostic test from a good idea to a clinically relevant tool takes several steps, with more stringent requirements at every step. This article aims to summarize the necessary questions to be asked about a test and to illustrate study designs answering these questions. We also aim to relate the Regulation (EU) 2017/746 to the needs of evidence-based diagnostic testing, where applicable. We used literature on evidence-based diagnostics, a text book on clinical trials in the development and marketing of medical devices and the English version of Regulation 2017/746 of the European Parliament and of the Council on in vitro diagnostic medical devices. The combination of different test uses and different stages of development determine the required test characteristics and suitability of study designs. In an earlier stage of test development it may be crucial to know whether a test can differentiate diseased persons from healthy controls, while this tells us little about how a test will perform in practice. Later stages focus on the diagnostic accuracy of a test in a clinically relevant situation. However, a test that perfectly distinguishes between patients with and without a certain condition may still have little effect on patient outcomes. Therefore, randomized controlled trials of testing may be needed, as well as post-marketing monitoring. Both researchers and users of tests need to be aware of the limitations of diagnostic test accuracy and realize that accuracy is only indirectly linked to people's health status. Copyright © 2018. Published by Elsevier Ltd.

  2. Diagnostic accuracy of apparent diffusion coefficient and 123I-metaiodobenzylguanidine for differentiation of multiple system atrophy and Parkinson's disease.

    PubMed

    Umemura, Atsushi; Oeda, Tomoko; Hayashi, Ryutaro; Tomita, Satoshi; Kohsaka, Masayuki; Yamamoto, Kenji; Sawada, Hideyuki

    2013-01-01

    It is often hard to differentiate Parkinson's disease (PD) and parkinsonian variant of multiple system atrophy (MSA-P), especially in the early stages. Cardiac sympathetic denervation and putaminal rarefaction are specific findings for PD and MSA-P, respectively. We investigated diagnostic accuracy of putaminal apparent diffusion coefficient (ADC) test for MSA-P and (123)I-metaiodobenzylguanidine (MIBG) scintigram for PD, especially in early-stage patients. The referral standard diagnosis of PD and MSA-P were the diagnostic criteria of the United Kingdom Parkinson's Disease Society Brain Bank Criteria and the second consensus criteria, respectively. Based on the referral standard criteria, diagnostic accuracy [area under the receiver-operator characteristic curve (AUC), sensitivity and specificity] of the ADC and MIBG tests was estimated retrospectively. Diagnostic accuracy of these tests performed within 3 years of symptom onset was also investigated. ADC and MIBG tests were performed on 138 patients (20 MSA and 118 PD). AUC was 0.95 and 0.83 for the ADC and MIBG tests, respectively. Sensitivity and specificity were 85.0% and 89.0% for MSA-P diagnosis by ADC test and 67.0% and 80.0% for PD diagnosis by MIBG test. When these tests were restricted to patients with disease duration ≤ 3 years, the sensitivity and specificity were 75.0% and 91.4% for the ADC test (MSA-P diagnosis) and 47.7% and 92.3% for the MIBG test (PD diagnosis). Both tests were useful in differentiating between PD and MSA-P, even in the early stages. In early-stage patients, elevated putaminal ADC was a diagnostic marker for MSA-P. Despite high specificity of the MIBG test, careful neurological history and examinations were required for PD diagnosis because of possible false-negative results.

  3. [Contrast agent improves diagnostic value of dobutamine stress echocardiography].

    PubMed

    Uehara, H; Yamamoto, T; Hirano, Y; Ozasa, Y; Yamada, S; Ikawa, H; Ishikawa, K

    2001-03-01

    Suboptimal endocardial definition reduces the diagnostic value of stress echocardiography for coronary artery disease, but intravenous infusion of a left ventricular contrast agent (Albunex) may enhance endocardial border delineation and improve the diagnostic value of dobutamine stress echocardiography. Fifty-six patients, 38 with myocardial infarction, 16 with angina pectoris and two normal subjects, were enrolled in this study. Dobutamine was infused in scalar doses of 5 to 40 micrograms/kg/min. Intravenous infusion of Albunex (0.15 ml/kg) was administered at rest and during peak dobutamine stress during monitoring of the apical four-chamber view. The left ventricle in the apical four-chamber view was divided into six segments and an endocardial delineation score of 0 to 3 (none to excellent visualization) was given to each segment. Endocardial delineation score was increased after Albunex infusion from 2.0 to 2.3 in the basal-septal, 2.0 to 2.4 in the mid-septal, 1.1 to 1.8 in the apical-septal, 0.7 to 1.2 in the apical-lateral, 0.9 to 1.6 in the mid-lateral, and 1.2 to 1.9 in the basal-lateral segments during peak dobutamine administration. Endocardial border resolution in the lateral wall showed greater improvement than in the septal wall after Albunex infusion. Diagnostic values in the left anterior descending artery territory failed to improve with Albunex infusion (sensitivity 82% to 89%, specificity 94% to 89%, and accuracy 86% to 89%), whereas a higher diagnostic accuracy was noted in the left circumflex artery territory with Albunex compared to without Albunex (sensitivity 63% to 81%, specificity 88% to 98%, and accuracy 80% to 93%, p < 0.05). Contrast agent improves the diagnostic accuracy of dobutamine stress echocardiography in the left circumflex artery territory.

  4. [Positron tomography with 18F-fluorodeoxyglucose in the preoperative evaluation of gall bladder lesions suspicious of malignancy. Diagnostic utility and clinical impact].

    PubMed

    Ramos-Font, C; Gómez Río, M; Rodríguez-Fernández, A; Sánchez Sánchez, R; Llamas Elvira, J M

    2011-01-01

    Gallbladder carcinoma is a neoplasm having a poor prognosis in which the role of the positron emission tomography with (18)F-fluordeoxyglucose as a diagnostic tool, although of possible usefulness, has not been well-defined. It is a prospective cohort of patients with radiologically malignant suspicious gallbladder lesions. A staging diagnostic presurgical FDG-PET study was carried out in each patient using both dedicated PET and multimodality PET-CT scanners. Diagnostic accuracy parameters were calculated from the results of PET imaging and were correlated with the condition and/or the clinical course of the patients. The clinical impact of its implementation in the diagnosis of gallbladder carcinoma was also analyzed. A total of 42 patients were recruited (22 malignant lesions, 20 benign). Overall diagnostic accuracy was 83.33% for the diagnosis of the primary lesion, 88.89% for the evaluation of lymph node involvement and 85.1% for the evaluation of metastatic disease. Mean SUVmax in malignant gallbladder lesions was 6.14±2.89. ROC curve showed a cut-off value of 3.65 in the SUVmax for malignancy. Accuracy of PET studies alone (n=21) was slightly lower than that of the PET/CT (n=21). FDG-PET changed the management of 14.8% of the population due to the identification of unsuspected metastatic disease. FDG-PET accurately diagnoses malignancy or benignity of suspicious gallbladder lesions, with the addition of its capacity to identify unsuspected metastatic disease. PET-CT improves the diagnostic accuracy of the procedure, due to the metabolic-structural complementarity of their information. The SUVmax has a complementary value added to the visual analysis. Copyright © 2010 Elsevier España, S.L. y SEMNIM. All rights reserved.

  5. Diagnostic accuracy of 18F-FDG-PET and PET/CT in the differential diagnosis between malignant and benign pleural lesions: a systematic review and meta-analysis.

    PubMed

    Treglia, Giorgio; Sadeghi, Ramin; Annunziata, Salvatore; Lococo, Filippo; Cafarotti, Stefano; Bertagna, Francesco; Prior, John O; Ceriani, Luca; Giovanella, Luca

    2014-01-01

    To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  6. Direct comparison of PI-RADS version 2 and version 1 regarding interreader agreement and diagnostic accuracy for the detection of clinically significant prostate cancer.

    PubMed

    Becker, Anton S; Cornelius, Alexander; Reiner, Cäcilia S; Stocker, Daniel; Ulbrich, Erika J; Barth, Borna K; Mortezavi, Ashkan; Eberli, Daniel; Donati, Olivio F

    2017-09-01

    to simultaneously evaluate interreader agreement and diagnostic accuracy in the of PI-RADS v2 and compare it to v1. A total of 67 patients (median age 65.3 y, range 51.2-78.2 y; PSA 6.8μg/L, 0.2-33μg/L) undergoing MRI of the prostate and subsequent transperineal template biopsy within ≤6 months from MRI were included. Four readers from two institutions evaluated the likelihood of prostate cancer using PI-RADS v1 and v2 in two separate reading sessions ≥3 months apart. Interreader agreement was assessed for each pulse-sequence and for total PI-RADS scores using the intraclass correlation coefficient (ICC). Differences were considered significant for non-overlapping 95%-confidence intervals. Diagnostic accuracy was assessed with the area under the receiver operating characteristic curve (A Z ). A p-value <0.05 was considered statistically significant. Interreader agreement for DCE-scores was good in v2 (ICC 2 =0.70; 95% CI: 0.66-0.74) and slightly lower in v1 (ICC 1 =0.64, 0.59-0.69). Agreement for DWI scores (ICC 1 =0.77, ICC 2 =0.76) as well as final PI-RADS scores per quadrant were nearly identical (ICC 1 =ICC 2 =0.71). Diagnostic accuracy showed no significant differences (p=0.09-0.93) between v1 and v2 in any of the readers (range: A Z =0.78-0.88). PI-RADS scores show similar interreader agreement in v2 and v1 at comparable diagnostic performance. The simplification of the DCE interpretation in v2 might slightly improve agreement while not negatively affecting diagnostic performance. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Sonography of the chest using linear-array versus sector transducers: Correlation with auscultation, chest radiography, and computed tomography.

    PubMed

    Tasci, Ozlem; Hatipoglu, Osman Nuri; Cagli, Bekir; Ermis, Veli

    2016-07-08

    The primary purpose of our study was to compare the efficacies of two sonographic (US) probes, a high-frequency linear-array probe and a lower-frequency phased-array sector probe in the diagnosis of basic thoracic pathologies. The secondary purpose was to compare the diagnostic performance of thoracic US with auscultation and chest radiography (CXR) using thoracic CT as a gold standard. In total, 55 consecutive patients scheduled for thoracic CT were enrolled in this prospective study. Four pathologic entities were evaluated: pneumothorax, pleural effusion, consolidation, and interstitial syndrome. A portable US scanner was used with a 5-10-MHz linear-array probe and a 1-5-MHz phased-array sector probe. The first probe used was chosen randomly. US, CXR, and auscultation results were compared with the CT results. The linear-array probe had the highest performance in the identification of pneumothorax (83% sensitivity, 100% specificity, and 99% diagnostic accuracy) and pleural effusion (100% sensitivity, 97% specificity, and 98% diagnostic accuracy); the sector probe had the highest performance in the identification of consolidation (89% sensitivity, 100% specificity, and 95% diagnostic accuracy) and interstitial syndrome (94% sensitivity, 93% specificity, and 94% diagnostic accuracy). For all pathologies, the performance of US was superior to those of CXR and auscultation. The linear probe is superior to the sector probe for identifying pleural pathologies, whereas the sector probe is superior to the linear probe for identifying parenchymal pathologies. Thoracic US has better diagnostic performance than CXR and auscultation for the diagnosis of common pathologic conditions of the chest. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 44:383-389, 2016. © 2016 Wiley Periodicals, Inc.

  8. Systematic Review of Health Economic Evaluations of Diagnostic Tests in Brazil: How accurate are the results?

    PubMed

    Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho

    2017-08-01

    The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.

  9. Diagnostic accuracy, risk assessment, and cost-effectiveness of component-resolved diagnostics for food allergy: A systematic review.

    PubMed

    Flores Kim, J; McCleary, N; Nwaru, B I; Stoddart, A; Sheikh, A

    2018-01-10

    Component-resolved diagnostics (CRD) are promising tools for diagnosing food allergy, offering the potential to determine specific phenotypes and to develop patient-tailored risk profiles. Nevertheless, the diagnostic accuracy of these tests varies across studies; thus, their clinical utility remains unclear. Therefore, we synthesized the evidence from studies investigating the diagnostic accuracy, risk assessment ability, and cost-effectiveness of CRD for food allergy. We systematically searched 10 electronic databases and four clinical trial registries for studies published from January 2000 to February 2017. The quality of included studies was assessed using QUADAS-2. Due to heterogeneity, we narratively synthesized the evidence. Eleven studies met inclusion criteria, altogether recruiting 1098 participants. The food allergies investigated were cow's milk, hen's egg, peanut, hazelnut, and shrimp. The components with the highest diagnostic accuracy for each allergen, along with their sensitivity-specificity pairs, were as follows: Bos d 4 for cow's milk (62.0% and 87.5%), Gal d 1 for hen's egg (84.2% and 89.8% for heated egg, and 60.6% and 97.1% for raw egg), Ara h 6 for peanut (94.9% and 95.1%), Cor a 14 for hazelnut (100% and 93.8%), and Lit v 1 for shrimp (82.8% and 56.3%) allergy. Selected components of cow's milk, hen's egg, peanut, hazelnut, and shrimp allergen showed high specificity, but lower sensitivity. However, few studies exist for each component, and studies vary widely regarding the cutoff values used, making it challenging to synthesize findings across studies. Further research is needed to determine clinically appropriate cutoff values, risk assessment abilities, and cost-effectiveness of CRD approaches. © 2018 The Authors. Allergy Published by John Wiley & Sons Ltd.

  10. Pharmacometabolomics Informs Quantitative Radiomics for Glioblastoma Diagnostic Innovation.

    PubMed

    Katsila, Theodora; Matsoukas, Minos-Timotheos; Patrinos, George P; Kardamakis, Dimitrios

    2017-08-01

    Applications of omics systems biology technologies have enormous promise for radiology and diagnostics in surgical fields. In this context, the emerging fields of radiomics (a systems scale approach to radiology using a host of technologies, including omics) and pharmacometabolomics (use of metabolomics for patient and disease stratification and guiding precision medicine) offer much synergy for diagnostic innovation in surgery, particularly in neurosurgery. This synthesis of omics fields and applications is timely because diagnostic accuracy in central nervous system tumors still challenges decision-making. Considering the vast heterogeneity in brain tumors, disease phenotypes, and interindividual variability in surgical and chemotherapy outcomes, we believe that diagnostic accuracy can be markedly improved by quantitative radiomics coupled to pharmacometabolomics and related health information technologies while optimizing economic costs of traditional diagnostics. In this expert review, we present an innovation analysis on a systems-level multi-omics approach toward diagnostic accuracy in central nervous system tumors. For this, we suggest that glioblastomas serve as a useful application paradigm. We performed a literature search on PubMed for articles published in English between 2006 and 2016. We used the search terms "radiomics," "glioblastoma," "biomarkers," "pharmacogenomics," "pharmacometabolomics," "pharmacometabonomics/pharmacometabolomics," "collaborative informatics," and "precision medicine." A list of the top 4 insights we derived from this literature analysis is presented in this study. For example, we found that (i) tumor grading needs to be better refined, (ii) diagnostic precision should be improved, (iii) standardization in radiomics is lacking, and (iv) quantitative radiomics needs to prove clinical implementation. We conclude with an interdisciplinary call to the metabolomics, pharmacy/pharmacology, radiology, and surgery communities that pharmacometabolomics coupled to information technologies (chemoinformatics tools, databases, collaborative systems) can inform quantitative radiomics, thus translating Big Data and information growth to knowledge growth, rational drug development and diagnostics innovation for glioblastomas, and possibly in other brain tumors.

  11. Engineering of the LukS-PV and LukF-PV subunits of Staphylococcus aureus Panton-Valentine leukocidin for diagnostic and therapeutic applications.

    PubMed

    Okolie, Charles Emeka; Cockayne, Alan; Penfold, Christopher; James, Richard

    2013-11-19

    Staphylococcus aureus produces several toxins, including Panton-Valentine leukocidin (PVL). The involvement of PVL in primary skin infections, necrotizing pneumonia, musculoskeletal disorders, brain abscess, and other diseases, some of which are life-threatening, has been reported. Following expert opinion, we aimed to provide the tools for establishment of sequence-based diagnostics and therapeutics for those conditions. We engineered the synergistic S and F (LukS-PV and LukF-PV respectively) pro-toxin subunits from Staphylococcus aureus USA400 into separate expression E. coli BL21(DE3)-pLysS hosts. Following Nickel affinity chromatography (NAC), the F subunit came out without bands of impurity. The S sub-unit did not come off very pure after NAC thus necessitating further purification by size exclusion and ion-exchange chromatography. The purification plots showed that the BioLogic-LP and AKTA systems are reliable for following the progress of the chromatographic purification in real-time. Computer predicted Mw for the 6His-LukF-PV and 6His-LukS-PV were 35645.41 Da and 33530.04 Da respectively, while the mass spectrometry results were 35643.57 Da and 33528.34 Da respectively. The BioLogic-LP and AKTA systems are commendable for reliability and user-friendliness. As a recent work elsewhere also reported that a second round of chromatography was necessary to purify the S subunit after the first attempt, we speculate that the S subunit might contain yet unidentified motif(s) requiring further treatment. The purified S and F sub-units of PVL were supplied to the Nottingham Cancer Immunotherapy group who used them to establish sequence-based monoclonal antibodies for diagnostic and therapeutic uses targeting PVL.

  12. A Prospective, Blinded, Multicenter Clinical Trial to Compare the Efficacy, Accuracy, and Safety of In-Office Diagnostic Arthroscopy With Magnetic Resonance Imaging and Surgical Diagnostic Arthroscopy.

    PubMed

    Gill, Thomas J; Safran, Marc; Mandelbaum, Bert; Huber, Bryan; Gambardella, Ralph; Xerogeanes, John

    2018-05-24

    The purpose of this study was to compare the efficacy, accuracy, and safety of in-office diagnostic arthroscopy with magnetic resonance imaging (MRI) and surgical diagnostic arthroscopy. A prospective, blinded, multicenter, clinical trial was performed on 110 patients, ages 18 to 75 years, who presented with knee pain. The study period was April 2012 to April 2013. Each patient underwent a physical examination, an MRI, in-office diagnostic imaging, and a diagnostic arthroscopic examination in the operating room. The attending physician completed clinical report forms comparing the in-office arthroscopic examination and surgical diagnostic arthroscopy findings on each patient. Two blinded experts, unaffiliated with the clinical care of the study's subjects, reviewed the in-office arthroscopic images and MRI images using the surgical diagnostic arthroscopy images as the "control" group comparison. Patients were consecutive, and no patients were excluded from the study. In this study, the accuracy, sensitivity, and specificity of in-office arthroscopy was equivalent to surgical diagnostic arthroscopy and more accurate than MRI. When comparing in-office arthroscopy with surgical diagnostic arthroscopy, all kappa statistics were between 0.766 and 0.902. For MRI compared with surgical diagnostic arthroscopy, kappa values ranged from a low of 0.130 (considered "slight" agreement) to a high of 0.535 (considered "moderate" agreement). The comparison of MRI to in-office arthroscopy showed very similar results as the comparison of MRI with surgical diagnostic arthroscopy, ranging from a low kappa of 0.112 (slight agreement) to a high of 0.546 (moderate agreement). There were no patient-related or device-related complications related to the use of in-office arthroscopy. Needle-based diagnostic imaging that can be used in the office setting is statistically equivalent to surgical diagnostic arthroscopy with regard to the diagnosis of intra-articular, nonligamentous knee joint pathology. In-office diagnostic imaging can provide a more detailed and accurate diagnostic assessment of intra-articular knee pathology than MRI. Based on the study results, in-office diagnostic imaging provides a safe, accurate, real-time, minimally invasive diagnostic modality to evaluate intra-articular pathology without the need for surgical diagnostic arthroscopy or high-cost imaging. Level II, comparative prospective trial. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Accuracy of a novel photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot

    NASA Astrophysics Data System (ADS)

    Gandhi, Neeraj; Kim, Sungmin; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2017-03-01

    Minimally invasive surgery carries the deadly risk of rupturing major blood vessels, such as the internal carotid arteries hidden by bone in endonasal transsphenoidal surgery. We propose a novel approach to surgical guidance that relies on photoacoustic-based vessel separation measurements to assess the extent of safety zones during these type of surgical procedures. This approach can be implemented with or without a robot or navigation system. To determine the accuracy of this approach, a custom phantom was designed and manufactured for modular placement of two 3.18-mm diameter vessel-mimicking targets separated by 10-20 mm. Photoacoustic images were acquired as the optical fiber was swept across the vessels in the absence and presence of teleoperation with a research da Vinci Surgical System. When the da Vinci was used, vessel positions were recorded based on the fiber position (calculated from the robot kinematics) that corresponded to an observed photoacoustic signal. In all cases, compounded photoacoustic data from a single sweep displayed the four vessel boundaries in one image. Amplitude- and coherence-based photoacoustic images were used to estimate vessel separations, resulting in 0.52-0.56 mm mean absolute errors, 0.66-0.71 mm root mean square errors, and 65-68% more accuracy compared to fiber position measurements obtained through the da Vinci robot kinematics. Results indicate that with further development, photoacoustic image-based measurements of anatomical landmarks could be a viable method for real-time path planning in multiple interventional photoacoustic applications.

  14. Diagnostic validity of methods for assessment of swallowing sounds: a systematic review.

    PubMed

    Taveira, Karinna Veríssimo Meira; Santos, Rosane Sampaio; Leão, Bianca Lopes Cavalcante de; Neto, José Stechman; Pernambuco, Leandro; Silva, Letícia Korb da; De Luca Canto, Graziela; Porporatti, André Luís

    2018-02-03

    Oropharyngeal dysphagia is a highly prevalent comorbidity in neurological patients and presents a serious health threat, which may lead to outcomes of aspiration pneumonia, ranging from hospitalization to death. This assessment proposes a non-invasive, acoustic-based method to differentiate between individuals with and without signals of penetration and aspiration. This systematic review evaluated the diagnostic validity of different methods for assessment of swallowing sounds, when compared to Videofluroscopic of Swallowing Study (VFSS) to detect oropharyngeal dysphagia. Articles in which the primary objective was to evaluate the accuracy of swallowing sounds were searched in five electronic databases with no language or time limitations. Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v. 5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. The final electronic search revealed 554 records, however only 3 studies met the inclusion criteria. The accuracy values (area under the curve) were 0.94 for microphone, 0.80 for Doppler, and 0.60 for stethoscope. Based on limited evidence and low methodological quality because few studies were included, with a small sample size, from all index testes found for this systematic review, Doppler showed excellent diagnostic accuracy for the discrimination of swallowing sounds, whereas microphone-reported good accuracy discrimination of swallowing sounds of dysphagic patients and stethoscope showed best screening test. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  15. Prime Diagnosticity in Short-Term Repetition Priming: Is Primed Evidence Discounted, Even when It Reliably Indicates the Correct Answer?

    ERIC Educational Resources Information Center

    Weidemann, Christoph T.; Huber, David E.; Shiffrin, Richard M.

    2008-01-01

    The authors conducted 4 repetition priming experiments that manipulated prime duration and prime diagnosticity in a visual forced-choice perceptual identification task. The strength and direction of prime diagnosticity produced marked effects on identification accuracy, but those effects were resistant to subsequent changes of diagnosticity.…

  16. Using computerised interactive response technology to assess electrocardiographers and for aggregating diagnoses.

    PubMed

    Peace, Aaron; Ramsewak, Adesh; Cairns, Andrew; Finlay, Dewar; Guldenring, Daniel; Clifford, Gari; Bond, Raymond

    2015-01-01

    The 12-lead electrocardiogram (ECG) is a crucial diagnostic tool. However, the ideal method to assess competency in ECG interpretation remains unclear. We sought to evaluate whether keypad response technology provides a rapid, interactive way to assess ECG knowledge. 75 participants were enrolled [32 (43%) Primary Care Physicians, 24 (32%) Hospital Medical Staff and 19 (25%) Nurse Practitioners]. Nineteen ECGs with 4 possible answers were interpreted. Out of 1425 possible decisions 1054 (73.9%) responses were made. Only 570/1425 (40%) of the responses were correct. Diagnostic accuracy varied (0% to 78%, mean 42%±21%) across the entire cohort. Participation was high, (median 83%, IQR 50%-100%). Hospital Medical Staff had significantly higher diagnostic accuracy than nurse practitioners (50±20% vs. 38±19%, p=0.04) and Primary Care Physicians (50±20% vs. 40±21%, p=0.07) although not significant. Interactive voting systems can be rapidly and successfully used to assess ECG interpretation. Further education is necessary to improve diagnostic accuracy. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  17. Accuracy of fundus autofluorescence imaging for the diagnosis and monitoring of retinal conditions: a systematic review.

    PubMed

    Frampton, Geoff K; Kalita, Neelam; Payne, Liz; Colquitt, Jill; Loveman, Emma

    2016-04-01

    Natural fluorescence in the eye may be increased or decreased by diseases that affect the retina. Imaging methods based on confocal scanning laser ophthalmoscopy (cSLO) can detect this 'fundus autofluorescence' (FAF) by illuminating the retina using a specific light 'excitation wavelength'. FAF imaging could assist the diagnosis or monitoring of retinal conditions. However, the accuracy of the method for diagnosis or monitoring is unclear. To conduct a systematic review to determine the accuracy of FAF imaging using cSLO for the diagnosis or monitoring of retinal conditions, including monitoring of response to therapy. Electronic bibliographic databases; scrutiny of reference lists of included studies and relevant systematic reviews; and searches of internet pages of relevant organisations, meetings and trial registries. Databases included MEDLINE, EMBASE, The Cochrane Library, Web of Science and the Medion database of diagnostic accuracy studies. Searches covered 1990 to November 2014 and were limited to the English language. References were screened for relevance using prespecified inclusion criteria to capture a broad range of retinal conditions. Two reviewers assessed titles and abstracts independently. Full-text versions of relevant records were retrieved and screened by one reviewer and checked by a second. Data were extracted and critically appraised using the Quality Assessment of Diagnostic Accuracy Studies criteria (QUADAS) for assessing risk of bias in test accuracy studies by one reviewer and checked by a second. At all stages any reviewer disagreement was resolved through discussion or arbitration by a third reviewer. Eight primary research studies have investigated the diagnostic accuracy of FAF imaging in retinal conditions: choroidal neovascularisation (one study), reticular pseudodrusen (three studies), cystoid macular oedema (two studies) and diabetic macular oedema (two studies). Sensitivity of FAF imaging using an excitation wavelength of 488 nm was generally high (range 81-100%), but was lower (55% and 32%) in two studies using longer excitation wavelengths (514 nm and 790 nm, respectively). Specificity ranged from 34% to 100%. However, owing to limitations of the data, none of the studies provide conclusive evidence of the diagnostic accuracy of FAF imaging. No studies on the accuracy of FAF imaging for monitoring the progression of retinal conditions or response to therapy were identified. Owing to study heterogeneity, pooling of diagnostic outcomes in meta-analysis was not conducted. All included studies had high risk of bias. In most studies the patient spectrum was not reflective of those who would present in clinical practice and no studies adequately reported how FAF images were interpreted. Although already in use in clinical practice, it is unclear whether or not FAF imaging is accurate, and whether or not it is applied and interpreted consistently for the diagnosis and/or monitoring of retinal conditions. Well-designed prospective primary research studies, which conform to the paradigm of diagnostic test accuracy assessment, are required to investigate the accuracy of FAF imaging in diagnosis and monitoring of inherited retinal dystrophies, early age-related macular degeneration, geographic atrophy and central serous chorioretinopathy. This study is registered as PROSPERO CRD42014014997. The National Institute for Health Research Health Technology Assessment programme.

  18. Diagnostic accuracy of fine-needle aspiration cytology in Warthin tumors.

    PubMed

    Veder, Laura L; Kerrebijn, Jeroen D F; Smedts, Frank M; den Bakker, Michael A

    2010-12-01

    Our aim was to evaluate the diagnostic accuracy of fine-needle aspiration cytology (FNAC) for Warthin tumors of the parotid gland. All cytologic diagnoses of Warthin tumor between 1990 and 2007 were correlated with available histology. In addition, our results were compared to current literature. In 310 cases, Warthin tumor was diagnosed by FNAC. In 133 cases, (43%) both cytology and histology were available. In 127 of these 133 cases (95.5%), the diagnosis Warthin tumor was confirmed by histology. In 4 cases (3%), a benign lesion was diagnosed and 2 (1.5%) revealed a malignant lesion. On review, those cytologic diagnoses were not certain. In the literature, 11 missed malignancies (5.4%) in 202 cases were reported. The diagnostic accuracy of FNAC for the diagnosis of Warthin tumor is high and the percentage of missed malignant tumors is very low. Our results imply that a cytologic diagnosis of Warthin tumor may justify conservative treatment.

  19. Myocardial perfusion imaging with PET

    PubMed Central

    Nakazato, Ryo; Berman, Daniel S; Alexanderson, Erick; Slomka, Piotr

    2013-01-01

    PET-myocardial perfusion imaging (MPI) allows accurate measurement of myocardial perfusion, absolute myocardial blood flow and function at stress and rest in a single study session performed in approximately 30 min. Various PET tracers are available for MPI, and rubidium-82 or nitrogen-13-ammonia is most commonly used. In addition, a new fluorine-18-based PET-MPI tracer is currently being evaluated. Relative quantification of PET perfusion images shows very high diagnostic accuracy for detection of obstructive coronary artery disease. Dynamic myocardial blood flow analysis has demonstrated additional prognostic value beyond relative perfusion imaging. Patient radiation dose can be reduced and image quality can be improved with latest advances in PET/CT equipment. Simultaneous assessment of both anatomy and perfusion by hybrid PET/CT can result in improved diagnostic accuracy. Compared with SPECT-MPI, PET-MPI provides higher diagnostic accuracy, using lower radiation doses during a shorter examination time period for the detection of coronary artery disease. PMID:23671459

  20. Parent-based diagnosis of ADHD is as accurate as a teacher-based diagnosis of ADHD.

    PubMed

    Bied, Adam; Biederman, Joseph; Faraone, Stephen

    2017-04-01

    To review the literature evaluating the psychometric properties of parent and teacher informants relative to a gold-standard ADHD diagnosis in pediatric populations. We included studies that included both a parent and teacher informant, a gold-standard diagnosis, and diagnostic accuracy metrics. Potential confounds were evaluated. We also assessed the 'OR' and the 'AND' rules for combining informant reports. Eight articles met inclusion criteria. The diagnostic accuracy for predicting gold standard ADHD diagnoses did not differ between parents and teachers. Sample size, sample type, participant drop-out, participant age, participant gender, geographic area of the study, and date of study publication were assessed as potential confounds. Parent and teachers both yielded moderate to good diagnostic accuracy for ADHD diagnoses. Parent reports were statistically indistinguishable from those of teachers. The predictive features of the 'OR' and 'AND' rules are useful in evaluating approaches to better integrating information from these informants.

  1. Diagnostic Performance of a Novel Coronary CT Angiography Algorithm: Prospective Multicenter Validation of an Intracycle CT Motion Correction Algorithm for Diagnostic Accuracy.

    PubMed

    Andreini, Daniele; Lin, Fay Y; Rizvi, Asim; Cho, Iksung; Heo, Ran; Pontone, Gianluca; Bartorelli, Antonio L; Mushtaq, Saima; Villines, Todd C; Carrascosa, Patricia; Choi, Byoung Wook; Bloom, Stephen; Wei, Han; Xing, Yan; Gebow, Dan; Gransar, Heidi; Chang, Hyuk-Jae; Leipsic, Jonathon; Min, James K

    2018-06-01

    Motion artifact can reduce the diagnostic accuracy of coronary CT angiography (CCTA) for coronary artery disease (CAD). The purpose of this study was to compare the diagnostic performance of an algorithm dedicated to correcting coronary motion artifact with the performance of standard reconstruction methods in a prospective international multicenter study. Patients referred for clinically indicated invasive coronary angiography (ICA) for suspected CAD prospectively underwent an investigational CCTA examination free from heart rate-lowering medications before they underwent ICA. Blinded core laboratory interpretations of motion-corrected and standard reconstructions for obstructive CAD (≥ 50% stenosis) were compared with ICA findings. Segments unevaluable owing to artifact were considered obstructive. The primary endpoint was per-subject diagnostic accuracy of the intracycle motion correction algorithm for obstructive CAD found at ICA. Among 230 patients who underwent CCTA with the motion correction algorithm and standard reconstruction, 92 (40.0%) had obstructive CAD on the basis of ICA findings. At a mean heart rate of 68.0 ± 11.7 beats/min, the motion correction algorithm reduced the number of nondiagnostic scans compared with standard reconstruction (20.4% vs 34.8%; p < 0.001). Diagnostic accuracy for obstructive CAD with the motion correction algorithm (62%; 95% CI, 56-68%) was not significantly different from that of standard reconstruction on a per-subject basis (59%; 95% CI, 53-66%; p = 0.28) but was superior on a per-vessel basis: 77% (95% CI, 74-80%) versus 72% (95% CI, 69-75%) (p = 0.02). The motion correction algorithm was superior in subgroups of patients with severely obstructive (≥ 70%) stenosis, heart rate ≥ 70 beats/min, and vessels in the atrioventricular groove. The motion correction algorithm studied reduces artifacts and improves diagnostic performance for obstructive CAD on a per-vessel basis and in selected subgroups on a per-subject basis.

  2. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  3. Diagnosis of Grave's disease with pulmonary hypertension on chest CT.

    PubMed

    Lee, Hwa Yeon; Yoo, Seung Min; Kim, Hye Rin; Chun, Eun Ju; White, Charles S

    To evaluate the diagnostic accuracy of chest CT findings to diagnose Grave's disease in pulmonary hypertension. We retrospectively evaluated chest CT and the medical records of 13 patients with Grave's disease with (n=6) or without pulmonary hypertension (n=7) and in 17 control patients. Presence of iso-attenuation of diffusely enlarged thyroid glands compared with adjacent neck muscle on non-enhanced CT as a diagnostic clue of Grave's disease, and assessment of pulmonary hypertension on CT has high diagnostic accuracy. Chest CT has the potential to diagnose Grave's disease with pulmonary hypertension in the absence of other information. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Gait dynamics to optimize fall risk assessment in geriatric patients admitted to an outpatient diagnostic clinic

    PubMed Central

    de Groot, Maartje H.; van Campen, Jos P.; Beijnen, Jos H.; Hortobágyi, Tibor; Vuillerme, Nicolas; Lamoth, Claudine C. J.

    2017-01-01

    Fall prediction in geriatric patients remains challenging because the increased fall risk involves multiple, interrelated factors caused by natural aging and/or pathology. Therefore, we used a multi-factorial statistical approach to model categories of modifiable fall risk factors among geriatric patients to identify fallers with highest sensitivity and specificity with a focus on gait performance. Patients (n = 61, age = 79; 41% fallers) underwent extensive screening in three categories: (1) patient characteristics (e.g., handgrip strength, medication use, osteoporosis-related factors) (2) cognitive function (global cognition, memory, executive function), and (3) gait performance (speed-related and dynamic outcomes assessed by tri-axial trunk accelerometry). Falls were registered prospectively (mean follow-up 8.6 months) and one year retrospectively. Principal Component Analysis (PCA) on 11 gait variables was performed to determine underlying gait properties. Three fall-classification models were then built using Partial Least Squares–Discriminant Analysis (PLS-DA), with separate and combined analyses of the fall risk factors. PCA identified ‘pace’, ‘variability’, and ‘coordination’ as key properties of gait. The best PLS-DA model produced a fall classification accuracy of AUC = 0.93. The specificity of the model using patient characteristics was 60% but reached 80% when cognitive and gait outcomes were added. The inclusion of cognition and gait dynamics in fall classification models reduced misclassification. We therefore recommend assessing geriatric patients’ fall risk using a multi-factorial approach that incorporates patient characteristics, cognition, and gait dynamics. PMID:28575126

  5. Gait dynamics to optimize fall risk assessment in geriatric patients admitted to an outpatient diagnostic clinic.

    PubMed

    Kikkert, Lisette H J; de Groot, Maartje H; van Campen, Jos P; Beijnen, Jos H; Hortobágyi, Tibor; Vuillerme, Nicolas; Lamoth, Claudine C J

    2017-01-01

    Fall prediction in geriatric patients remains challenging because the increased fall risk involves multiple, interrelated factors caused by natural aging and/or pathology. Therefore, we used a multi-factorial statistical approach to model categories of modifiable fall risk factors among geriatric patients to identify fallers with highest sensitivity and specificity with a focus on gait performance. Patients (n = 61, age = 79; 41% fallers) underwent extensive screening in three categories: (1) patient characteristics (e.g., handgrip strength, medication use, osteoporosis-related factors) (2) cognitive function (global cognition, memory, executive function), and (3) gait performance (speed-related and dynamic outcomes assessed by tri-axial trunk accelerometry). Falls were registered prospectively (mean follow-up 8.6 months) and one year retrospectively. Principal Component Analysis (PCA) on 11 gait variables was performed to determine underlying gait properties. Three fall-classification models were then built using Partial Least Squares-Discriminant Analysis (PLS-DA), with separate and combined analyses of the fall risk factors. PCA identified 'pace', 'variability', and 'coordination' as key properties of gait. The best PLS-DA model produced a fall classification accuracy of AUC = 0.93. The specificity of the model using patient characteristics was 60% but reached 80% when cognitive and gait outcomes were added. The inclusion of cognition and gait dynamics in fall classification models reduced misclassification. We therefore recommend assessing geriatric patients' fall risk using a multi-factorial approach that incorporates patient characteristics, cognition, and gait dynamics.

  6. Urinary Metabolomic Profiling to Identify Potential Biomarkers for the Diagnosis of Behcet's Disease by Gas Chromatography/Time-of-Flight-Mass Spectrometry.

    PubMed

    Ahn, Joong Kyong; Kim, Jungyeon; Hwang, Jiwon; Song, Juhwan; Kim, Kyoung Heon; Cha, Hoon-Suk

    2017-11-02

    Diagnosing Behcet's disease (BD) is challenging because of the lack of a diagnostic biomarker. The purposes of this study were to investigate distinctive metabolic changes in urine samples of BD patients and to identify urinary metabolic biomarkers for diagnosis of BD using gas chromatography/time-of-flight-mass spectrometry (GC/TOF-MS). Metabolomic profiling of urine samples from 44 BD patients and 41 healthy controls (HC) were assessed using GC/TOF-MS, in conjunction with multivariate statistical analysis. A total of 110 urinary metabolites were identified. The urine metabolite profiles obtained from GC/TOF-MS analysis could distinguish BD patients from the HC group in the discovery set. The parameter values of the orthogonal partial least squared-discrimination analysis (OPLS-DA) model were R ² X of 0.231, R ² Y of 0.804, and Q ² of 0.598. A biomarker panel composed of guanine, pyrrole-2-carboxylate, 3-hydroxypyridine, mannose, l-citrulline, galactonate, isothreonate, sedoheptuloses, hypoxanthine, and gluconic acid lactone were selected and adequately validated as putative biomarkers of BD (sensitivity 96.7%, specificity 93.3%, area under the curve 0.974). OPLS-DA showed clear discrimination of BD and HC groups by a biomarker panel of ten metabolites in the independent set (accuracy 88%). We demonstrated characteristic urinary metabolic profiles and potential urinary metabolite biomarkers that have clinical value in the diagnosis of BD using GC/TOF-MS.

  7. [Western Blot diagnostic yield for simultaneous antibody-detection in patients with human cysticercosis, hydatidosis, and human fascioliasis].

    PubMed

    Davelois, Kelly; Escalante, Hermes; Jara, César

    2016-01-01

    . To determine the diagnostic yield using western blotting to simultaneously detect antibodies in patients with human cysticercosis, hydatidosis, and human fascioliasis. Materials and methods . Cross-sectional study of diagnostic yield assessment. Excretory/secretory antigens were obtained from Taenia solium larvae, Echinococcus granulosus cysts, and the adult flukes of Fasciola hepática, which were then separated using the polyacrylamide gel electrophoresis technique, transferred, and attached to a nitrocellulose membrane to be probed with sera from the patient infected with the three parasites. The sensitivity of the technique was assessed using 300 individual serum samples, 60 pools of two parasites, and 20 pools of three parasites with 75 sera from patients with other parasites, 10 from patients with other diseases, and 15 from patients without parasites. Results . The technique revealed 13 glycoproteins (GP): GP 35, 31, 24, 23, 18, 17, 14, and 13 kDa for cysticercosis; GP 8, 16, and 21 kDa for hydatidosis; and GP 17 and 23 kDa for fascioliasis. The test detected the presence of antibodies with a sensitivity of 96% (95% confidence interval [CI] = 94.62-98.54%) in the detection of one or the thirteen bands, a specificity of 100% (95% CI = 99.50-100.00%); individually, there was a sensitivity for cysticercosis of 97% (95% CI = 93.16-100.00%), for hydatidosis of 94% (95% CI = 88.85-99.15%) and for fascioliasis of 96% (95% CI = 91.66-100.00%). Conclusions . Western blotting is effective in the simultaneous detection of antibodies in patients with human cysticercosis, hydatidosis, and fascioliasis, and it can be used as a diagnostic test to either rule out or confirm the presence of antibodies in endemic areas.

  8. 76 FR 1126 - Wireless E911 Location Accuracy Requirements; E911 Requirements for IP-Enabled Service Providers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-07

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 20 [PS Docket No. 07-114; WC Docket No. 05-196; FCC 10-177; DA 10-2267] Wireless E911 Location Accuracy Requirements; E911 Requirements for IP-Enabled Service Providers AGENCY: Federal Communications Commission. ACTION: Proposed rule; extension of comment...

  9. Diagnostic Accuracy of Molecular Amplification Tests for Human African Trypanosomiasis—Systematic Review

    PubMed Central

    Boer, Kimberly R.; Dyserinck, Heleen C.; Büscher, Philippe; Schallig, Henk D. H. F.; Leeflang, Mariska M. G.

    2012-01-01

    Background A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Methodology Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. Results 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Conclusion Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately. PMID:22253934

  10. Diagnostic accuracy of molecular amplification tests for human African trypanosomiasis--systematic review.

    PubMed

    Mugasa, Claire M; Adams, Emily R; Boer, Kimberly R; Dyserinck, Heleen C; Büscher, Philippe; Schallig, Henk D H F; Leeflang, Mariska M G

    2012-01-01

    A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately.

  11. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear: A Systematic Review With Meta-analysis.

    PubMed

    Reiman, Michael P; Thorborg, Kristian; Goode, Adam P; Cook, Chad E; Weir, Adam; Hölmich, Per

    2017-09-01

    Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Summarize and evaluate the diagnostic accuracy and clinical utility of various imaging modalities and injection techniques relevant to hip FAI/ALT. Systematic review with meta-analysis. A computer-assisted literature search was conducted of MEDLINE, CINAHL, and EMBASE databases using keywords related to diagnostic accuracy of hip joint pathologic changes. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were used for the search and reporting phases of the study. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies (QUADAS) tool. Random effects models were used to summarize sensitivities (SN), specificities (SP), likelihood ratios (+LR and -LR), diagnostic odds ratios (DOR), and respective confidence intervals (CI). The search strategy and assessment for risk of bias revealed 25 articles scoring above 10/14 on the items of the QUADAS. Four studies investigated FAI, and the data were not pooled. Twenty articles on ALT qualified for meta-analysis. Pretest probability of ALT in the studies in this review was 81% (72%-88%), while the pretest probability of FAI diagnosis was 74% (95% CI, 51%-91%). The meta-analysis showed that computed tomography arthrography (CTA) demonstrated the strongest overall diagnostic accuracy: pooled SN 0.91 (95% CI, 0.83-0.96); SP 0.89 (95% CI, 0.74-0.97); +LR 6.28 (95% CI, 2.78-14.21); -LR 0.11 (95% CI, 0.06-0.21); and DOR 64.38 (95% CI, 19.17-216.21). High pretest probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US) and by a moderate degree for CTA. Negative imaging findings decreased the probability that a labral tear existed by a minimal degree with the use of MRI and US, a small to moderate degree with MRA, and a moderate degree with CTA. Although findings of the included studies suggested potentially favorable use of these modalities for the diagnosis of ALT and FAI, our results suggest that these findings have limited generalizability and clinical utility given very high pretest prevalence, large confidence intervals, and selection criteria of the studies. Registration: PROSPERO Registration #CRD42015027745.

  12. Technical Advances in Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition for Pancreatic Cancers: How Can We Get the Best Results with EUS-Guided Fine Needle Aspiration?

    PubMed Central

    Kedia, Prashant; Gaidhane, Monica

    2013-01-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is one of the least invasive and most effective modality in diagnosing pancreatic adenocarcinoma in solid pancreatic lesions, with a higher diagnostic accuracy than cystic tumors. EUS-FNA has been shown to detect tumors less than 3 mm, due to high spatial resolution allowing the detection of very small lesions and vascular invasion, particularly in the pancreatic head and neck, which may not be detected on transverse computed tomography. Furthermore, this minimally invasive procedure is often ideal in the endoscopic procurement of tissue in patients with unresectable tumors. While EUS-FNA has been increasingly used as a diagnostic tool, most studies have collectively looked at all primary pancreatic solid lesions, including lymphomas and pancreatic neuroendocrine neoplasms, whereas very few studies have examined the diagnostic utility of EUS-FNA of pancreatic ductal carcinoma only. As with any novel and advanced endoscopic procedure that may incorporate several practices and approaches, endoscopists have adopted diverse techniques to improve the tissue procurement practice and increase diagnostic accuracy. In this article, we present a review of literature to date and discuss currently practiced EUS-FNA technique, including indications, technical details, equipment, patient selection, and diagnostic accuracy. PMID:24143320

  13. Bootstrap-based procedures for inference in nonparametric receiver-operating characteristic curve regression analysis.

    PubMed

    Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G

    2018-03-01

    Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.

  14. Paracheck® rapid diagnostic test for detecting malaria infection in under five children: a population-based survey in Burkina Faso.

    PubMed

    Samadoulougou, Sekou; Kirakoya-Samadoulougou, Fati; Sarrassat, Sophie; Tinto, Halidou; Bakiono, Fidèle; Nebié, Issa; Robert, Annie

    2014-03-17

    Over the past ten years, Rapid Diagnostic Tests (RDT) played a major role in improving the use of biological malaria diagnosis, in particular in poor-resources settings. In Burkina Faso, a recent Demography and Health Survey (DHS) gave the opportunity to assess the performance of the Paracheck® test in under five children nationwide at community level. A national representative sample of 14,947 households was selected using a stratified two-stage cluster sampling. In one out of two households, all under five children were eligible to be tested for malaria using both RDT and microscopy diagnosis. Paracheck® performance was assessed using miscroscopy as the gold standard. Sensitivity and specificity were calculated as well as the diagnosis accuracy (DA) and the Youden index. The malaria infection prevalence was estimated at 66% (95% CI: 64.8-67.2) according to microscopy and at 76.2% (95% CI: 75.1-77.3) according to Paracheck®. The sensitivity and specificity were estimated at 89.9% (95% CI: 89.0-90.8) and 50.4% (95% CI: 48.3-52.6) respectively with a Diagnosis Accuracy of 77% and a Youden index of 40%. The positive predictive value for malaria infection was 77.9% (95% CI: 76.7-79.1) and the negative predictive value was 72.1% (95% CI: 69.7-74.3). Variations were found by age group, period of the year and urban and rural areas, as well as across the 13 regions of the country. While the sensitivity of the Paracheck® test was high, its specificity was poor in the general under five population of Burkina Faso. These results suggest that Paracheck® is not suitable to assess malaria infection prevalence at community level in areas with high malaria transmission. In such settings, malaria prevalence in the general population could be estimated using microscopy.

  15. Diagnostic accuracy of refractometer and Brix refractometer to assess failure of passive transfer in calves: protocol for a systematic review and meta-analysis.

    PubMed

    Buczinski, S; Fecteau, G; Chigerwe, M; Vandeweerd, J M

    2016-06-01

    Calves are highly dependent of colostrum (and antibody) intake because they are born agammaglobulinemic. The transfer of passive immunity in calves can be assessed directly by dosing immunoglobulin G (IgG) or by refractometry or Brix refractometry. The latter are easier to perform routinely in the field. This paper presents a protocol for a systematic review meta-analysis to assess the diagnostic accuracy of refractometry or Brix refractometry versus dosage of IgG as a reference standard test. With this review protocol we aim to be able to report refractometer and Brix refractometer accuracy in terms of sensitivity and specificity as well as to quantify the impact of any study characteristic on test accuracy.

  16. The development of a quality appraisal tool for studies of diagnostic reliability (QAREL).

    PubMed

    Lucas, Nicholas P; Macaskill, Petra; Irwig, Les; Bogduk, Nikolai

    2010-08-01

    In systematic reviews of the reliability of diagnostic tests, no quality assessment tool has been used consistently. The aim of this study was to develop a specific quality appraisal tool for studies of diagnostic reliability. Key principles for the quality of studies of diagnostic reliability were identified with reference to epidemiologic principles, existing quality appraisal checklists, and the Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) resources. Specific items that encompassed each of the principles were developed. Experts in diagnostic research provided feedback on the items that were to form the appraisal tool. This process was iterative and continued until consensus among experts was reached. The Quality Appraisal of Reliability Studies (QAREL) checklist includes 11 items that explore seven principles. Items cover the spectrum of subjects, spectrum of examiners, examiner blinding, order effects of examination, suitability of the time interval among repeated measurements, appropriate test application and interpretation, and appropriate statistical analysis. QAREL has been developed as a specific quality appraisal tool for studies of diagnostic reliability. The reliability of this tool in different contexts needs to be evaluated. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  17. How to conduct a high-quality original study on a diagnostic research topic.

    PubMed

    Yao, Xiaomei; Vella, Emily

    2017-09-01

    As health research methodologists and journal reviewers, we noticed that the methodological rigor of many publications on diagnostic or prognostic topics in the medical literature could be improved. We present a concise and clear series of reviews to help clinicians and health researchers to master the basic key components of how to conduct a high-quality original study or systematic review on a diagnostic or prognostic research topic from a methodological perspective. This is the first review of the series, which focuses on how to conduct a high-quality diagnostic study. We are introducing four aspects: clarifying the objectives; generating an appropriate research question; planning the study design; and reporting and analyzing data. This review highlights that diagnostic test accuracy outcomes are surrogates for patient outcomes, a diagnostic test has three roles, the "PIRO" components should be included in a diagnostic research question, a new study should be registered, multiple index tests can be compared in one study, and prevalence affects test accuracy outcomes. This review also emphasizes reporting any thresholds, calculating sample size, and performing a two-by-three table to calculate diagnostic outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Simultaneous inter-arm and inter-leg systolic blood pressure differences to diagnose peripheral artery disease: a diagnostic accuracy study.

    PubMed

    Herráiz-Adillo, Ángel; Soriano-Cano, Alba; Martínez-Hortelano, José Alberto; Garrido-Miguel, Miriam; Mariana-Herráiz, Julián Ángel; Martínez-Vizcaíno, Vicente; Notario-Pacheco, Blanca

    2018-04-01

    Inter-arm systolic blood pressure differences (IASBPD) and inter-leg systolic blood pressure differences (ILSBPD) have arisen as potential tools to detect peripheral artery disease (PAD) and individuals at high cardiovascular risk. This study aims to evaluate the diagnostic accuracy of IASBPD and ILSBPD to detect PAD, and whether IASBPD or ILSBPD improves diagnostic accuracy of the oscillometric ankle-brachial index (ABI). In this prospective study, eligible for inclusion were consecutive adults, with at least one of the following cardiovascular risk factors: diabetes, dyslipidemia, hypertension, smoking habit or age ≥65. IASBPD, ILSBPD and ankle-brachial index (ABI) were measured in all participants through four-limb simultaneous oscillometric measurements and compared with Doppler ABI (reference test, positive cut-off: ≤ 0.9). Of 171 subjects included, PAD was confirmed in 23 and excluded in 148. Thirteen and 38 subjects had IASBPD and ILSBPD ≥10 mmHg, respectively. Pearson correlation with Doppler ABI of IASBPD and ILSBPD was 0.073 (P = .343) and -0.628 (P < .001), respectively. Diagnostic accuracy of an ILSBPD ≥10 mmHg to detect PAD was: sensitivity = 69.6% (95%CI = 48.6-90.5), specificity = 85.1% (79.1-91.2), diagnostic odds ratio (dOR) = 13.1 (4.8-35.5) and area under ROC curve (AUC) = 0.765 (0.616-0.915). IASBPD had an AUC = 0.532 (0.394-0.669), and oscillometric ABI had an AUC = 0.977 (0.950-1.000). The addition of ILSBPD to oscillometric ABI reduced dOR from 174.0 (38.3-789.9) to 34.4 (9.5-125.1). Similarly, the addition of IASBPD reduced dOR to 49.3 (14.6-167.0). In a Primary Care population with ≥1 cardiovascular risk factors, ILSBPD showed acceptable diagnostic accuracy for PAD, whilst IASBPD accuracy was negligible. However, the combination of ILSBPD (or IASBPD) with oscillometric ABI did not improve the ability to detect PAD. Thus, oscillometer ABI seems to be preferable to detect PAD and individuals at high cardiovascular risk. ILSBPD could be uniquely recommended for the diagnosis of PAD when blood pressure measurements in upper limbs are not possible.

  19. Acoustic radiation force impulse elastography, FibroScan®, Forns’ index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods

    PubMed Central

    DONG, DAO-RAN; HAO, MEI-NA; LI, CHENG; PENG, ZE; LIU, XIA; WANG, GUI-PING; MA, AN-LIN

    2015-01-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns’ index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty-one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal-Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal-Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=−0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of these methods. PMID:25651500

  20. Acoustic radiation force impulse elastography, FibroScan®, Forns' index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods.

    PubMed

    Dong, Dao-Ran; Hao, Mei-Na; Li, Cheng; Peng, Ze; Liu, Xia; Wang, Gui-Ping; Ma, An-Lin

    2015-06-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns' index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty‑one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal‑Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal‑Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=‑0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of these methods.

  1. Sweat conductivity: an accurate diagnostic test for cystic fibrosis?

    PubMed

    Mattar, Ana Claudia Veras; Leone, Claudio; Rodrigues, Joaquim Carlos; Adde, Fabíola Villac

    2014-09-01

    Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. Sweat conductivity is widely used although still considered a screening test. This was a prospective, cross-sectional, diagnostic research conducted at the laboratory of the Instituto da Criança of the Hospital das Clínicas, São Paulo, Brazil. Sweat chloride (quantitative pilocarpine iontophoresis) and sweat conductivity tests were simultaneously performed in patients referred for a sweat test between March 2007 and October 2008. Conductivity and chloride cut-off values used to rule out or diagnose CF were <75 and ≥90 mmol/L and <60 and ≥60 mmol/L, respectively. The ROC curve method was used to calculate the sensitivity, specificity, positive (PPV) and negative predictive value (NPV), as well as the respective 95% confidence intervals and to calculate the area under the curve for both tests. The kappa coefficient was used to evaluate agreement between the tests. Both tests were performed in 738 children, and CF was ruled out in 714 subjects; the median sweat chloride and conductivity values were 11 and 25 mmol/L in these populations, respectively. Twenty-four patients who had received a diagnosis of CF presented median sweat chloride and conductivity values of 87 and 103 mmol/L, respectively. Conductivity values above 90 mmol/L had 83.3% sensitivity, 99.7% specificity, 90.9% PPV and 99.4% NPV to diagnose CF. The best conductivity cut-off value to exclude CF was <75 mmol/L. Good agreement was observed between the tests (kappa: 0.934). The sweat conductivity test yielded a high degree of diagnostic accuracy and it showed good agreement with sweat chloride. We suggest that it should play a role as a diagnostic test for CF in the near future. Copyright © 2014 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  2. The diagnostic accuracy of multi-frequency bioelectrical impedance analysis in diagnosing dehydration after stroke.

    PubMed

    Kafri, Mohannad W; Myint, Phyo Kway; Doherty, Danielle; Wilson, Alexander Hugh; Potter, John F; Hooper, Lee

    2013-07-10

    Non-invasive methods for detecting water-loss dehydration following acute stroke would be clinically useful. We evaluated the diagnostic accuracy of multi-frequency bioelectrical impedance analysis (MF-BIA) against reference standards serum osmolality and osmolarity. Patients admitted to an acute stroke unit were recruited. Blood samples for electrolytes and osmolality were taken within 20 minutes of MF-BIA. Total body water (TBW%), intracellular (ICW%) and extracellular water (ECW%), as percentages of total body weight, were calculated by MF-BIA equipment and from impedance measures using published equations for older people. These were compared to hydration status (based on serum osmolality and calculated osmolarity). The most promising Receiver Operating Characteristics curves were plotted. 27 stroke patients were recruited (mean age 71.3, SD10.7). Only a TBW% cut-off at 46% was consistent with current dehydration (serum osmolality >300 mOsm/kg) and TBW% at 47% impending dehydration (calculated osmolarity ≥295-300 mOsm/L) with sensitivity and specificity both >60%. Even here diagnostic accuracy of MF-BIA was poor, a third of those with dehydration were wrongly classified as hydrated and a third classified as dehydrated were well hydrated. Secondary analyses assessing diagnostic accuracy of TBW% for men and women separately, and using TBW as a percentage of lean body mass showed some promise, but did not provide diagnostically accurate measures across the population. MF-BIA appears ineffective at diagnosing water-loss dehydration after stroke and cannot be recommended as a test for dehydration, but separating assessment by sex, and using TBW as a percentage of lean body weight may warrant further investigation.

  3. Improved Diagnostic Accuracy of SPECT Through Statistical Analysis and the Detection of Hot Spots at the Primary Sensorimotor Area for the Diagnosis of Alzheimer Disease in a Community-Based Study: "The Osaki-Tajiri Project".

    PubMed

    Kaneta, Tomohiro; Nakatsuka, Masahiro; Nakamura, Kei; Seki, Takashi; Yamaguchi, Satoshi; Tsuboi, Masahiro; Meguro, Kenichi

    2016-01-01

    SPECT is an important diagnostic tool for dementia. Recently, statistical analysis of SPECT has been commonly used for dementia research. In this study, we evaluated the accuracy of visual SPECT evaluation and/or statistical analysis for the diagnosis (Dx) of Alzheimer disease (AD) and other forms of dementia in our community-based study "The Osaki-Tajiri Project." Eighty-nine consecutive outpatients with dementia were enrolled and underwent brain perfusion SPECT with 99mTc-ECD. Diagnostic accuracy of SPECT was tested using 3 methods: visual inspection (SPECT Dx), automated diagnostic tool using statistical analysis with easy Z-score imaging system (eZIS Dx), and visual inspection plus eZIS (integrated Dx). Integrated Dx showed the highest sensitivity, specificity, and accuracy, whereas eZIS was the second most accurate method. We also observed that a higher than expected rate of SPECT images indicated false-negative cases of AD. Among these, 50% showed hypofrontality and were diagnosed as frontotemporal lobar degeneration. These cases typically showed regional "hot spots" in the primary sensorimotor cortex (ie, a sensorimotor hot spot sign), which we determined were associated with AD rather than frontotemporal lobar degeneration. We concluded that the diagnostic abilities were improved by the integrated use of visual assessment and statistical analysis. In addition, the detection of a sensorimotor hot spot sign was useful to detect AD when hypofrontality is present and improved the ability to properly diagnose AD.

  4. Diagnostic accuracy for major depression in multiple sclerosis using self-report questionnaires

    PubMed Central

    Fischer, Anja; Fischer, Marcus; Nicholls, Robert A; Lau, Stephanie; Poettgen, Jana; Patas, Kostas; Heesen, Christoph; Gold, Stefan M

    2015-01-01

    Objective Multiple sclerosis and major depressive disorder frequently co-occur but depression often remains undiagnosed in this population. Self-rated depression questionnaires are a good option where clinician-based standardized diagnostics are not feasible. However, there is a paucity of data on diagnostic accuracy of self-report measures for depression in multiple sclerosis (MS). Moreover, head-to-head comparisons of common questionnaires are largely lacking. This could be particularly relevant for high-risk patients with depressive symptoms. Here, we compare the diagnostic accuracy of the Beck Depression Inventory (BDI) and 30-item version of the Inventory of Depressive Symptomatology Self-Rated (IDS-SR30) for major depressive disorder (MSS) against diagnosis by a structured clinical interview. Methods Patients reporting depressive symptoms completed the BDI, the IDS-SR30 and underwent diagnostic assessment (Mini International Neuropsychiatric Interview, M.I.N.I.). Receiver-Operating Characteristic analyses were performed, providing error estimates and false-positive/negative rates of suggested thresholds. Results Data from n = 31 MS patients were available. BDI and IDS-SR30 total score were significantly correlated (r = 0.82). The IDS-SR30total score, cognitive subscore, and BDI showed excellent to good accuracy (area under the curve (AUC) 0.86, 0.91, and 0.85, respectively). Conclusion Both the IDS-SR30 and the BDI are useful to quantify depressive symptoms showing good sensitivity and specificity. The IDS-SR30 cognitive subscale may be useful as a screening tool and to quantify affective/cognitive depressive symptomatology. PMID:26445703

  5. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    PubMed

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  6. Combining functional and structural tests improves the diagnostic accuracy of relevance vector machine classifiers

    PubMed Central

    Racette, Lyne; Chiou, Christine Y.; Hao, Jiucang; Bowd, Christopher; Goldbaum, Michael H.; Zangwill, Linda M.; Lee, Te-Won; Weinreb, Robert N.; Sample, Pamela A.

    2009-01-01

    Purpose To investigate whether combining optic disc topography and short-wavelength automated perimetry (SWAP) data improves the diagnostic accuracy of relevance vector machine (RVM) classifiers for detecting glaucomatous eyes compared to using each test alone. Methods One eye of 144 glaucoma patients and 68 healthy controls from the Diagnostic Innovations in Glaucoma Study were included. RVM were trained and tested with cross-validation on optimized (backward elimination) SWAP features (thresholds plus age; pattern deviation (PD); total deviation (TD)) and on Heidelberg Retina Tomograph II (HRT) optic disc topography features, independently and in combination. RVM performance was also compared to two HRT linear discriminant functions (LDF) and to SWAP mean deviation (MD) and pattern standard deviation (PSD). Classifier performance was measured by the area under the receiver operating characteristic curves (AUROCs) generated for each feature set and by the sensitivities at set specificities of 75%, 90% and 96%. Results RVM trained on combined HRT and SWAP thresholds plus age had significantly higher AUROC (0.93) than RVM trained on HRT (0.88) and SWAP (0.76) alone. AUROCs for the SWAP global indices (MD: 0.68; PSD: 0.72) offered no advantage over SWAP thresholds plus age, while the LDF AUROCs were significantly lower than RVM trained on the combined SWAP and HRT feature set and on HRT alone feature set. Conclusions Training RVM on combined optimized HRT and SWAP data improved diagnostic accuracy compared to training on SWAP and HRT parameters alone. Future research may identify other combinations of tests and classifiers that can also improve diagnostic accuracy. PMID:19528827

  7. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    PubMed Central

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  8. Real-time teleophthalmology versus face-to-face consultation: A systematic review.

    PubMed

    Tan, Irene J; Dobson, Lucy P; Bartnik, Stephen; Muir, Josephine; Turner, Angus W

    2017-08-01

    Introduction Advances in imaging capabilities and the evolution of real-time teleophthalmology have the potential to provide increased coverage to areas with limited ophthalmology services. However, there is limited research assessing the diagnostic accuracy of face-to-face teleophthalmology consultation. This systematic review aims to determine if real-time teleophthalmology provides comparable accuracy to face-to-face consultation for the diagnosis of common eye health conditions. Methods A search of PubMed, Embase, Medline and Cochrane databases and manual citation review was conducted on 6 February and 7 April 2016. Included studies involved real-time telemedicine in the field of ophthalmology or optometry, and assessed diagnostic accuracy against gold-standard face-to-face consultation. The revised quality assessment of diagnostic accuracy studies (QUADAS-2) tool assessed risk of bias. Results Twelve studies were included, with participants ranging from four to 89 years old. A broad number of conditions were assessed and include corneal and retinal pathologies, strabismus, oculoplastics and post-operative review. Quality assessment identified a high or unclear risk of bias in patient selection (75%) due to an undisclosed recruitment processes. The index test showed high risk of bias in the included studies, due to the varied interpretation and conduct of real-time teleophthalmology methods. Reference standard risk was overall low (75%), as was the risk due to flow and timing (75%). Conclusion In terms of diagnostic accuracy, real-time teleophthalmology was considered superior to face-to-face consultation in one study and comparable in six studies. Store-and-forward image transmission coupled with real-time videoconferencing is a suitable alternative to overcome poor internet transmission speeds.

  9. Combining information from 3 anatomic regions in the diagnosis of glaucoma with time-domain optical coherence tomography.

    PubMed

    Wang, Mingwu; Lu, Ake Tzu-Hui; Varma, Rohit; Schuman, Joel S; Greenfield, David S; Huang, David

    2014-03-01

    To improve the diagnosis of glaucoma by combining time-domain optical coherence tomography (TD-OCT) measurements of the optic disc, circumpapillary retinal nerve fiber layer (RNFL), and macular retinal thickness. Ninety-six age-matched normal and 96 perimetric glaucoma participants were included in this observational, cross-sectional study. Or-logic, support vector machine, relevance vector machine, and linear discrimination function were used to analyze the performances of combined TD-OCT diagnostic variables. The area under the receiver-operating curve (AROC) was used to evaluate the diagnostic accuracy and to compare the diagnostic performance of single and combined anatomic variables. The best RNFL thickness variables were the inferior (AROC=0.900), overall (AROC=0.892), and superior quadrants (AROC=0.850). The best optic disc variables were horizontal integrated rim width (AROC=0.909), vertical integrated rim area (AROC=0.908), and cup/disc vertical ratio (AROC=0.890). All macular retinal thickness variables had AROCs of 0.829 or less. Combining the top 3 RNFL and optic disc variables in optimizing glaucoma diagnosis, support vector machine had the highest AROC, 0.954, followed by or-logic (AROC=0.946), linear discrimination function (AROC=0.946), and relevance vector machine (AROC=0.943). All combination diagnostic variables had significantly larger AROCs than any single diagnostic variable. There are no significant differences among the combination diagnostic indices. With TD-OCT, RNFL and optic disc variables had better diagnostic accuracy than macular retinal variables. Combining top RNFL and optic disc variables significantly improved diagnostic performance. Clinically, or-logic classification was the most practical analytical tool with sufficient accuracy to diagnose early glaucoma.

  10. The diagnostic performance of perfusion MRI for differentiating glioma recurrence from pseudoprogression: A meta-analysis.

    PubMed

    Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo

    2017-03-01

    The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.

  11. Measuring diagnostic and predictive accuracy in disease management: an introduction to receiver operating characteristic (ROC) analysis.

    PubMed

    Linden, Ariel

    2006-04-01

    Diagnostic or predictive accuracy concerns are common in all phases of a disease management (DM) programme, and ultimately play an influential role in the assessment of programme effectiveness. Areas, such as the identification of diseased patients, predictive modelling of future health status and costs and risk stratification, are just a few of the domains in which assessment of accuracy is beneficial, if not critical. The most commonly used analytical model for this purpose is the standard 2 x 2 table method in which sensitivity and specificity are calculated. However, there are several limitations to this approach, including the reliance on a single defined criterion or cut-off for determining a true-positive result, use of non-standardized measurement instruments and sensitivity to outcome prevalence. This paper introduces the receiver operator characteristic (ROC) analysis as a more appropriate and useful technique for assessing diagnostic and predictive accuracy in DM. Its advantages include; testing accuracy across the entire range of scores and thereby not requiring a predetermined cut-off point, easily examined visual and statistical comparisons across tests or scores, and independence from outcome prevalence. Therefore the implementation of ROC as an evaluation tool should be strongly considered in the various phases of a DM programme.

  12. Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy

    PubMed Central

    Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum

    2017-01-01

    Background: The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. Objectives: The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Design: Retrospective study. Methods: Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. Results: The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% (P < 0.0001); specificity, 98.53% and 86.76% (P = 0.0026); accuracy, 77.04% and 85.93% (P = 0.0423), respectively. Conclusions: The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test. PMID:28824298

  13. High diagnostic accuracy of histone H4-IgG autoantibodies in systemic lupus erythematosus.

    PubMed

    Vordenbäumen, Stefan; Böhmer, Paloma; Brinks, Ralph; Fischer-Betz, Rebecca; Richter, Jutta; Bleck, Ellen; Rengers, Petra; Göhler, Heike; Zucht, Hans-Dieter; Budde, Petra; Schulz-Knappe, Peter; Schneider, Matthias

    2018-03-01

    Diagnosis of SLE relies on the detection of autoantibodies. We aimed to assess the diagnostic potential of histone H4 and H2A variant antibodies in SLE. IgG-autoantibodies to histones H4 (HIST1H4A), H2A type 2-A (HIST2H2AA3) and H2A type 2-C (HIST2H2AC) were measured along with a standard antibody (SA) set including SSA, SSB, Sm, U1-RNP and RPLP2 in a multiplex magnetic microsphere-based assay in 153 SLE patients [85% female, 41 (13.5) years] and 81 healthy controls [77% female, 43.3 (12.4) years]. Receiver operating characteristic analysis was performed to assess diagnostic performance of individual markers. Logistic regression analysis was performed on a random split of samples to determine the additional value of histone antibodies in comparison with SA by likelihood ratio test and determination of diagnostic accuracy in the remaining validation samples. Microsphere-based assay showed good interclass correlation (mean 0.85, range 0.73-0.99) and diagnostic performance in receiver operating characteristic analysis (area under the curve (AUC) range 84.8-93.2) compared with routine assay for SA parameters. HIST1H4A-IgG was the marker with the best individual diagnostic performance for SLE vs healthy (AUC 0.97, sensitivity 95% at 90% specificity). HIST1H4A-IgG was an independent significant predictor for the diagnosis of SLE in multivariate modelling (P < 0.0001), and significantly improved prediction of SLE over SA parameters alone (residual deviance 45.9 vs 97.1, P = 4.3 × 10-11). Diagnostic accuracy in the training and validation samples was 89 and 86% for SA, and 95 and 89% with the addition of HIST1H4A-IgG. HIST1H4A-IgG antibodies improve diagnostic accuracy for SLE vs healthy. © The Author(s) 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. [br]For Permissions, please email: journals.permissions@oup.com

  14. Impact of arrhythmia on diagnostic performance of adenosine stress CMR in patients with suspected or known coronary artery disease.

    PubMed

    Greulich, Simon; Steubing, Hannah; Birkmeier, Stefan; Grün, Stefan; Bentz, Kerstin; Sechtem, Udo; Mahrholdt, Heiko

    2015-11-05

    The diagnostic performance of adenosine stress cardiovascular magnetic resonance (CMR) in patients with arrhythmias presenting for work-up of suspected or known CAD is largely unknown, since most CMR studies currently available exclude arrhythmic patients from analysis fearing gating problems, or other artifacts will impair image quality. The primary aim of our study was to evaluate the diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for 1) work-up of suspected coronary artery disease (CAD), or 2) work-up of ischemia in known CAD. Patients with arrhythmia referred for work-up of suspected CAD or work-up of ischemia in known CAD undergoing adenosine stress CMR were included if they had coronary angiography within four weeks of CMR. One hundred fifty-nine patients were included (n = 64 atrial fibrillation, n = 87 frequent ventricular extrasystoles, n = 8 frequent supraventricular extrasystoles). Of these, n = 72 had suspected CAD, and n = 87 had known CAD. Diagnostic accuracy of the adenosine stress CMR for detection of significant CAD was 73 % for the entire population (sensitivity 72 %, specificity 76 %). Diagnostic accuracy was 75 % (sensitivity 80 %, specificity 74 %) in patients with suspected CAD, and 74 % (sensitivity 71 %, specificity 79 %) in the group with known CAD. For different types of arrhythmia, diagnostic accuracy of CMR was 70 % in the atrial fibrillation group, and 79 % in patients with ventricular extrasystoles. On a per coronary territory analysis, diagnostic accuracy of CMR was 77 % for stenosis of the left and 82 % for stenosis of the right coronary artery. The present data demonstrates good diagnostic performance of adenosine stress CMR for detection of significant coronary stenosis in patients with arrhythmia presenting for work-up of suspected CAD, or work-up of ischemia in known CAD. This holds true for a per patient, as well as for a per coronary territory analysis.

  15. ECM1 and TMPRSS4 Are Diagnostic Markers of Malignant Thyroid Neoplasms and Improve the Accuracy of Fine Needle Aspiration Biopsy

    PubMed Central

    Kebebew, Electron; Peng, Miao; Reiff, Emily; Duh, Quan-Yang; Clark, Orlo H.; McMillan, Alex

    2005-01-01

    Objective: The objective of this study was to determine whether genes that regulate cellular invasion and metastasis are differentially expressed and could serve as diagnostic markers of malignant thyroid nodules. Summary and Background Data: Patients whose thyroid nodules have indeterminate or suspicious cytologic features on fine needle aspiration (FNA) biopsy require thyroidectomy because of a 20% to 30% risk of thyroid cancer. Cell invasion and metastasis is a hallmark of malignant phenotype; therefore, genes that regulate these processes might be differentially expressed and could serve as diagnostic markers of malignancy. Methods: Differentially expressed genes (2-fold higher or lower) in malignant versus benign thyroid neoplasms were identified by extracellular matrix and adhesion molecule cDNA array analysis and confirmed by real-time quantitative polymerase chain reaction (PCR). The area under the receiver operating characteristic (AUC) curve was calculated to determine diagnostic accuracy of gene expression level cutoffs established by logistic regression analysis. Results: By cDNA array analysis, ADAMTS8, ECM1, MMP8, PLAU, SELP, and TMPRSS4 were upregulated, and by quantitative PCR, ECM1, SELP, and TMPRSS4 mRNA expression was higher in malignant (n = 57) than in benign (n = 38) thyroid neoplasms (P< 0.002). ECM1 and TMPRSS4 mRNA expression levels were independent predictors of a malignant thyroid neoplasm (P < 0.003). The AUC was 0.956 for ECM1 and 0.926 for TMPRSS4. Combining both markers improved their diagnostic use (AUC 0.985; sensitivity, 91.7%; specificity, 89.8%; positive predictive value, 85.7%; negative predictive value, 82.8%). ECM1 and TMPRSS4 expression analysis improved the diagnostic accuracy of FNA biopsy in 35 of 38 indeterminate or suspicious results. The level of ECM1 mRNA expression was higher in TNM stage I differentiated thyroid cancers than in stage II and III tumors (P ≤ 0.031). Conclusions: ECM1 and TMPRSS4 are excellent diagnostic markers of malignant thyroid nodules and may be used to improve the diagnostic accuracy of FNA biopsy. ECM1 is also a marker of the extent of disease in differentiated thyroid cancers. PMID:16135921

  16. Development of an integrated Sasang constitution diagnosis method using face, body shape, voice, and questionnaire information

    PubMed Central

    2012-01-01

    Background Sasang constitutional medicine (SCM) is a unique form of traditional Korean medicine that divides human beings into four constitutional types (Tae-Yang: TY, Tae-Eum: TE, So-Yang: SY, and So-Eum: SE), which differ in inherited characteristics, such as external appearance, personality traits, susceptibility to particular diseases, drug responses, and equilibrium among internal organ functions. According to SCM, herbs that belong to a certain constitution cannot be used in patients with other constitutions; otherwise, this practice may result in no effect or in an adverse effect. Thus, the diagnosis of SC type is the most crucial step in SCM practice. The diagnosis, however, tends to be subjective due to a lack of quantitative standards for SC diagnosis. Methods We have attempted to make the diagnosis method as objective as possible by basing it on an analysis of quantitative data from various Oriental medical clinics. Four individual diagnostic models were developed with multinomial logistic regression based on face, body shape, voice, and questionnaire responses. Inspired by SCM practitioners’ holistic diagnostic processes, an integrated diagnostic model was then proposed by combining the four individual models. Results The diagnostic accuracies in the test set, after the four individual models had been integrated into a single model, improved to 64.0% and 55.2% in the male and female patient groups, respectively. Using a cut-off value for the integrated SC score, such as 1.6, the accuracies increased by 14.7% in male patients and by 4.6% in female patients, which showed that a higher integrated SC score corresponded to a higher diagnostic accuracy. Conclusions This study represents the first trial of integrating the objectification of SC diagnosis based on quantitative data and SCM practitioners’ holistic diagnostic processes. Although the diagnostic accuracy was not great, it is noted that the proposed diagnostic model represents common rules among practitioners who have various points of view. Our results are expected to contribute as a desirable research guide for objective diagnosis in traditional medicine, as well as to contribute to the precise diagnosis of SC types in an objective manner in clinical practice. PMID:22762505

  17. Development of an integrated Sasang constitution diagnosis method using face, body shape, voice, and questionnaire information.

    PubMed

    Do, Jun-Hyeong; Jang, Eunsu; Ku, Boncho; Jang, Jun-Su; Kim, Honggie; Kim, Jong Yeol

    2012-07-04

    Sasang constitutional medicine (SCM) is a unique form of traditional Korean medicine that divides human beings into four constitutional types (Tae-Yang: TY, Tae-Eum: TE, So-Yang: SY, and So-Eum: SE), which differ in inherited characteristics, such as external appearance, personality traits, susceptibility to particular diseases, drug responses, and equilibrium among internal organ functions. According to SCM, herbs that belong to a certain constitution cannot be used in patients with other constitutions; otherwise, this practice may result in no effect or in an adverse effect. Thus, the diagnosis of SC type is the most crucial step in SCM practice. The diagnosis, however, tends to be subjective due to a lack of quantitative standards for SC diagnosis. We have attempted to make the diagnosis method as objective as possible by basing it on an analysis of quantitative data from various Oriental medical clinics. Four individual diagnostic models were developed with multinomial logistic regression based on face, body shape, voice, and questionnaire responses. Inspired by SCM practitioners' holistic diagnostic processes, an integrated diagnostic model was then proposed by combining the four individual models. The diagnostic accuracies in the test set, after the four individual models had been integrated into a single model, improved to 64.0% and 55.2% in the male and female patient groups, respectively. Using a cut-off value for the integrated SC score, such as 1.6, the accuracies increased by 14.7% in male patients and by 4.6% in female patients, which showed that a higher integrated SC score corresponded to a higher diagnostic accuracy. This study represents the first trial of integrating the objectification of SC diagnosis based on quantitative data and SCM practitioners' holistic diagnostic processes. Although the diagnostic accuracy was not great, it is noted that the proposed diagnostic model represents common rules among practitioners who have various points of view. Our results are expected to contribute as a desirable research guide for objective diagnosis in traditional medicine, as well as to contribute to the precise diagnosis of SC types in an objective manner in clinical practice.

  18. An update of the appraisal of the accuracy and utility of cervical discography in chronic neck pain.

    PubMed

    Onyewu, Obi; Manchikanti, Laxmaiah; Falco, Frank J E; Singh, Vijay; Geffert, Stephanie; Helm, Standiford; Cohen, Steven P; Hirsch, Joshua A

    2012-01-01

    Chronic neck pain represents a significant public health problem. Despite high prevalence rates, there is a lack of consensus regarding the causes or treatments for this condition. Based on controlled evaluations, the cervical intervertebral discs, facet joints, and atlantoaxial joints have all been implicated as pain generators. Cervical provocation discography, which includes disc stimulation and morphological evaluation, is occasionally used to distinguish a painful disc from other potential sources of pain. Yet in the absence of validation and controlled outcome studies, the procedure remains mired in controversy. A systematic review of the diagnostic accuracy of cervical discography. To systematically evaluate and update the diagnostic accuracy of cervical discography. The available literature on cervical discography was reviewed. Methodological quality assessment of included studies was performed using Quality Appraisal of Reliability Studies (QAREL). Only diagnostic accuracy studies meeting at least 50% of the designated inclusion criteria were utilized for analysis. However, studies scoring less than 50% are presented descriptively and analyzed critically. The level of evidence was classified as good, fair, and limited or poor based on the quality of evidence developed by the U.S. Preventive Services Task Force (USPSTF).Data sources included relevant literature identified through searches of PubMed and EMBASE from 1966 to June 2012, and manual searches of the bibliographies of known primary and review articles. A total of 41 manuscripts were considered for accuracy and utility of cervical discography in chronic neck pain. There were 23 studies evaluating accuracy of discography. There were 3 studies meeting inclusion criteria for assessing the accuracy and prevalence of discography, with a prevalence of 16% to 53%. Based on modified Agency for Healthcare Research and Quality (AHRQ) accuracy evaluation and United States Preventive Services Task Force (USPSTF) level of evidence criteria, this systematic review indicates the strength of evidence is limited for the diagnostic accuracy of cervical discography. Limitations include a paucity of literature, poor methodological quality, and very few studies performed utilizing International Association for the Study of Pain (IASP) criteria. There is limited evidence for the diagnostic accuracy of cervical discography. Nevertheless, in the absence of any other means to establish a relationship between pathology and symptoms, cervical provocation discography may be an important evaluation tool in certain contexts to identify a subset of patients with chronic neck pain secondary to intervertebral disc disorders. Based on the current systematic review, cervical provocation discography performed according to the IASP criteria with control disc(s), and a minimum provoked pain intensity of 7 of 10, or at least 70% reproduction of worst pain (i.e. worst spontaneous pain of 7 = 7 x 70% = 5), may be a useful tool for evaluating chronic pain and cervical disc abnormalities in a small proportion of patients.

  19. Comparison of digital tomosynthesis and chest radiography for the detection of pulmonary nodules: systematic review and meta-analysis.

    PubMed

    Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Kim, Hyun J; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S

    2016-12-01

    To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83-0.88] and the specificity was 0.95 (0.93-0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44-0.51) and 0.37 (0.34-0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63-3.19). DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules.

  20. Seeking a valid gold standard for an innovative, dialect-neutral language test.

    PubMed

    Pearson, Barbara Zurer; Jackson, Janice E; Wu, Haotian

    2014-04-01

    PURPOSE In this study, the authors explored alternative gold standards to validate an innovative, dialect-neutral language assessment. METHOD Participants were 78 African American children, ages 5;0 (years;months) to 6;11. Twenty participants had previously been identified as having language impairment. The Diagnostic Evaluation of Language Variation-Norm Referenced (DELV-NR; Seymour, Roeper, & J. de Villiers, 2005) was administered, and concurrent language samples (LSs) were collected. Using LS profiles as the gold standard, sensitivity, specificity, and other measures of diagnostic accuracy were compared for diagnoses made from the DELV-NR and participants' clinical status prior to recruitment. In a second analysis, the authors used results from the first analysis to make evidence-based adjustments in the estimates of DELV-NR diagnostic accuracy. RESULTS Accuracy of the DELV-NR relative to LS profiles was greater than that of prior diagnoses, indicating that the DELV-NR was an improvement over preexisting diagnoses for this group. Specificity met conventional standards, but sensitivity was somewhat low. Reanalysis using the positive and negative predictive power of the preexisting diagnosis in a discrepant-resolution procedure revealed that estimates for sensitivity and specificity for the DELV-NR were .85 and .93, respectively. CONCLUSION The authors found that, even after making allowances for the imperfection of available gold standards, clinical decisions made with the DELV-NR achieved high values on conventional measures of diagnostic accuracy.

  1. The diagnostic accuracy of dermoscopy for scabies.

    PubMed

    Park, Ju Hyuk; Kim, Chul Woo; Kim, Sang Seok

    2012-05-01

    Scabies is a contagious skin infestation characterized clinically by nocturnal pruritus, visible burrows and contagiousness. Dermoscopy has been suggested as an alternative for diagnosing scabies. But, there have been few well-designed studies evaluating the diagnostic accuracy of dermoscopy. We tried to confirm the diagnostic accuracy of dermoscopy for diagnosing scabies. We also tried to demonstrate specific circumstances in which dermoscopic identification of mites ("with dermoscopy") is more useful in diagnosing scabies, and to identify the specific clinical findings that could be used as a possible marker in diagnosing scabies. We compared the scraping procedure "with dermoscopy" and "without it" in 49 patients, measuring the duration and outcome of each procedure. Also, we tried to find the specific clinical factors associated with our objects. The skin scraping "with dermoscopy" was superior to "without it" with respect to the duration and accuracy of the procedure. A history of previous steroid treatment was associated with the superiority of dermoscopy. The correlation between the presence of visible burrows and the positive outcomes of "with dermoscopy" was statistically significant. Skin scraping with dermoscopy is implicated as the diagnostic method of choice for scabies at the present time. Dermoscopy is especially useful in diagnosis of incognito scabies. In addition, the presence of visible burrows could be a reliable positive marker of scabies in the absence of dermoscopy or microscopy data.

  2. Diagnostic accuracy of presepsin (sCD14-ST) as a biomarker of infection and sepsis in the emergency department.

    PubMed

    de Guadiana Romualdo, Luis García; Torrella, Patricia Esteban; Acebes, Sergio Rebollo; Otón, María Dolores Albaladejo; Sánchez, Roberto Jiménez; Holgado, Ana Hernando; Santos, Enrique Jiménez; Freire, Alejandro Ortín

    2017-01-01

    Presepsin is a promising biomarker for the diagnosis and prognosis of sepsis. However, results reported about its value to diagnose sepsis in an emergency department (ED) are controversial, probably due to differences in the design of the studies. We have evaluated the diagnostic accuracy of presepsin for infection and sepsis, compared with procalcitonin (PCT) and C-reactive protein (CRP), in patients presenting to the emergency department (ED) with suspected infection. 223 patients with suspected infection were enrolled for the study. Blood samples were collected on admission for measurement of biomarkers. Definitive diagnosis was obtained afterwards by analysis of digital medical records. Receiver operating characteristic (ROC) curve analysis was conducted to determine the diagnostic accuracy. Infection was confirmed in 200 patients, including 130 with non-complicated infection and 70 with sepsis. Median CRP, PCT and presepsin levels were significantly higher in patients with infection and sepsis. PCT was the biomarker with the highest performance for infection (ROC AUC: 0.910); for sepsis, PCT (ROC AUC: 0.815) and presepsin (ROC AUC: 0.775) shown a similar performance. Although presepsin is a valuable biomarker for diagnosis of infection and sepsis, its diagnostic accuracy in our study does not improve that of PCT. Its introduction in clinical practice is not justified. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis.

    PubMed

    Iskandar, Aline; Limone, Brendan; Parker, Matthew W; Perugini, Andrew; Kim, Hyejin; Jones, Charles; Calamari, Brian; Coleman, Craig I; Heller, Gary V

    2013-02-01

    It remains controversial whether the diagnostic accuracy of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) is different in men as compared to women. We performed a meta-analysis to investigate gender differences of SPECT MPI for the diagnosis of CAD (≥50% stenosis). Two investigators independently performed a systematic review of the MEDLINE and EMBASE databases from inception through January 2012 for English-language studies determining the diagnostic accuracy of SPECT MPI. We included prospective studies that compared SPECT MPI with conventional coronary angiography which provided sufficient data to calculate gender-specific true and false positives and negatives. Data from studies evaluating <20 patients of one gender were excluded. Bivariate meta-analysis was used to create summary receiver operating curves. Twenty-six studies met inclusion criteria, representing 1,148 women and 1,142 men. Bivariate meta-analysis yielded a mean sensitivity and specificity of 84.2% (95% confidence interval [CI] 78.7%-88.6%) and 78.7% (CI 70.0%-85.3%) for SPECT MPI in women and 89.1% (CI 84.0%-92.7%) and 71.2% (CI 60.8%-79.8%) for SPECT MPI in men. There was no significant difference in the sensitivity (P = .15) or specificity (P = .23) between male and female subjects. In a bivariate meta-analysis of the available literature, the diagnostic accuracy of SPECT MPI is similar for both men and women.

  4. Diagnostic accuracy of contrast enhanced ultrasound in patients with blunt abdominal trauma presenting to the emergency department: a systematic review and meta-analysis.

    PubMed

    Zhang, Zhongheng; Hong, Yucai; Liu, Ning; Chen, Yuhao

    2017-06-30

    We aimed to investigate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in evaluating blunt abdominal trauma for patients presenting to the emergency department. Electronic search of Scopus and Pubmed was performed from inception to September 2016. Human studies investigating the diagnostic accuracy of CEUS in identifying abdominal solid organ injuries were included. Risk of bias was assessed using the QUADAS tool. A total of 10 studies were included in the study and 9 of them were included for meta-analysis. The log(DOR) values ranged from 3.80 (95% CI: 2.81-4.79) to 8.52 (95% CI: 4.58-12.47) in component studies. The combined log(DOR) was 6.56 (95% CI: 5.66-7.45). The Cochran's Q was 11.265 (p = 0.793 with 16 degrees of freedom), and the Higgins' I 2 was 0%. The CEUS had a sensitivity of 0.981 (95% CI: 0.868-0.950) and a false positive rate of 0.018 (95% CI: 0.010-0.032) for identifying parenchymal injuries, with an AUC of 0.984. CEUS performed at emergency department had good diagnostic accuracy in identifying abdominal solid organ injuries. CEUS can be recommended in monitoring solid organ injuries, especially for patients managed with non-operative strategy.

  5. Effect of Reduced Tube Voltage on Diagnostic Accuracy of CT Colonography.

    PubMed

    Futamata, Yoshihiro; Koide, Tomoaki; Ihara, Riku

    2017-01-01

    The normal tube voltage in computed tomography colonography (CTC) is 120 kV. Some reports indicate that the use of a low tube voltage (lower than 120 kV) technique plays a significant role in reduction of radiation dose. However, to determine whether a lower tube voltage can reduce radiation dose without compromising diagnostic accuracy, an evaluation of images that are obtained while maintaining the volume CT dose index (CTDI vol ) is required. This study investigated the effect of reduced tube voltage in CTC, without modifying radiation dose (i.e. constant CTDI vol ), on image quality. Evaluation of image quality involved the shape of the noise power spectrum, surface profiling with volume rendering (VR), and receiver operating characteristic (ROC) analysis. The shape of the noise power spectrum obtained with a tube voltage of 80 kV and 100 kV was not similar to the one produced with a tube voltage of 120 kV. Moreover, a higher standard deviation was observed on volume-rendered images that were generated using the reduced tube voltages. In addition, ROC analysis revealed a statistically significant drop in diagnostic accuracy with reduced tube voltage, revealing that the modification of tube voltage affects volume-rendered images. The results of this study suggest that reduction of tube voltage in CTC, so as to reduce radiation dose, affects image quality and diagnostic accuracy.

  6. Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria

    PubMed Central

    Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.

    2013-01-01

    Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403

  7. Limits of the possible: diagnostic image quality in coronary angiography with third-generation dual-source CT.

    PubMed

    Ochs, Marco M; Siepen, Fabian Aus dem; Fritz, Thomas; Andre, Florian; Gitsioudis, Gitsios; Korosoglou, Grigorios; Seitz, Sebastian; Bogomazov, Yuriy; Schlett, Christopher L; Sokiranski, Roman; Sommer, Andre; Gückel, Friedemann; Brado, Matthias; Kauczor, Hans-Ulrich; Görich, Johannes; Friedrich, Matthias G W; Katus, Hugo A; Buss, Sebastian J

    2017-07-01

    The usage of coronary CT angiography (CTA) is appropriate in patients with acute or chronic chest pain; however the diagnostic accuracy may be challenged with increased Agatston score (AS), increased heart rate, arrhythmia and severe obesity. Thus, we aim to determine the potential of the recently introduced third-generation dual-source CT (DSCT) for CTA in a 'real-life' clinical setting. Two hundred and sixty-eight consecutive patients (age: 67 ± 10 years; BMI: 27 ± 5 kg/m²; 61% male) undergoing clinically indicated CTA with DSCT were included in the retrospective single-center analysis. A contrast-enhanced volume dataset was acquired in sequential (SSM) (n = 151) or helical scan mode (HSM) (n = 117). Coronary segments were classified in diagnostic or non-diagnostic image quality. A subset underwent invasive angiography to determine the diagnostic accuracy of CTA. SSM (96.8 ± 6%) and HSM (97.5 ± 8%) provided no significant differences in the overall diagnostic image quality. However, AS had significant influence on diagnostic image quality exclusively in SSM (B = 0.003; p = 0.0001), but not in HSM. Diagnostic image quality significantly decreased in SSM in patients with AS ≥2,000 (p = 0.03). SSM (sensitivity: 93.9%; specificity: 96.7%; PPV: 88.6%; NPV: 98.3%) and HSM (sensitivity: 97.4%; specificity: 94.3%; PPV: 86.0%; NPV: 99.0%) provided comparable diagnostic accuracy (p = n.s.). SSM yielded significantly lower radiation doses as compared to HSM (2.1 ± 2.0 vs. 5.1 ± 3.3 mSv; p = 0.0001) in age and BMI-matched cohorts. SSM in third-generation DSCT enables significant dose savings and provides robust diagnostic image quality in patients with AS ≤2000 independent of heart rate, heart rhythm or obesity.

  8. A genetic programming approach for Burkholderia Pseudomallei diagnostic pattern discovery

    PubMed Central

    Yang, Zheng Rong; Lertmemongkolchai, Ganjana; Tan, Gladys; Felgner, Philip L.; Titball, Richard

    2009-01-01

    Motivation: Finding diagnostic patterns for fighting diseases like Burkholderia pseudomallei using biomarkers involves two key issues. First, exhausting all subsets of testable biomarkers (antigens in this context) to find a best one is computationally infeasible. Therefore, a proper optimization approach like evolutionary computation should be investigated. Second, a properly selected function of the antigens as the diagnostic pattern which is commonly unknown is a key to the diagnostic accuracy and the diagnostic effectiveness in clinical use. Results: A conversion function is proposed to convert serum tests of antigens on patients to binary values based on which Boolean functions as the diagnostic patterns are developed. A genetic programming approach is designed for optimizing the diagnostic patterns in terms of their accuracy and effectiveness. During optimization, it is aimed to maximize the coverage (the rate of positive response to antigens) in the infected patients and minimize the coverage in the non-infected patients while maintaining the fewest number of testable antigens used in the Boolean functions as possible. The final coverage in the infected patients is 96.55% using 17 of 215 (7.4%) antigens with zero coverage in the non-infected patients. Among these 17 antigens, BPSL2697 is the most frequently selected one for the diagnosis of Burkholderia Pseudomallei. The approach has been evaluated using both the cross-validation and the Jack–knife simulation methods with the prediction accuracy as 93% and 92%, respectively. A novel approach is also proposed in this study to evaluate a model with binary data using ROC analysis. Contact: z.r.yang@ex.ac.uk PMID:19561021

  9. Receiver operating characteristic analysis of eyewitness memory: comparing the diagnostic accuracy of simultaneous versus sequential lineups.

    PubMed

    Mickes, Laura; Flowe, Heather D; Wixted, John T

    2012-12-01

    A police lineup presents a real-world signal-detection problem because there are two possible states of the world (the suspect is either innocent or guilty), some degree of information about the true state of the world is available (the eyewitness has some degree of memory for the perpetrator), and a decision is made (identifying the suspect or not). A similar state of affairs applies to diagnostic tests in medicine because, in a patient, the disease is either present or absent, a diagnostic test yields some degree of information about the true state of affairs, and a decision is made about the presence or absence of the disease. In medicine, receiver operating characteristic (ROC) analysis is the standard method for assessing diagnostic accuracy. By contrast, in the eyewitness memory literature, this powerful technique has never been used. Instead, researchers have attempted to assess the diagnostic performance of different lineup procedures using methods that cannot identify the better procedure (e.g., by computing a diagnosticity ratio). Here, we describe the basics of ROC analysis, explaining why it is needed and showing how to use it to measure the performance of different lineup procedures. To illustrate the unique advantages of this technique, we also report 3 ROC experiments that were designed to investigate the diagnostic accuracy of simultaneous versus sequential lineups. According to our findings, the sequential procedure appears to be inferior to the simultaneous procedure in discriminating between the presence versus absence of a guilty suspect in a lineup.

  10. Comparison of the Effectiveness of Interactive Didactic Lecture Versus Online Simulation-Based CME Programs Directed at Improving the Diagnostic Capabilities of Primary Care Practitioners.

    PubMed

    McFadden, Pam; Crim, Andrew

    2016-01-01

    Diagnostic errors in primary care contribute to increased morbidity and mortality, and billions in costs each year. Improvements in the way practicing physicians are taught so as to optimally perform differential diagnosis can increase patient safety and lower the costs of care. This study represents a comparison of the effectiveness of two approaches to CME training directed at improving the primary care practitioner's diagnostic capabilities against seven common and important causes of joint pain. Using a convenience sampling methodology, one group of primary care practitioners was trained by a traditional live, expert-led, multimedia-based training activity supplemented with interactive practice opportunities and feedback (control group). The second group was trained online with a multimedia-based training activity supplemented with interactive practice opportunities and feedback delivered by an artificial intelligence-driven simulation/tutor (treatment group). Before their respective instructional intervention, there were no significant differences in the diagnostic performance of the two groups against a battery of case vignettes presenting with joint pain. Using the same battery of case vignettes to assess postintervention diagnostic performance, there was a slight but not statistically significant improvement in the control group's diagnostic accuracy (P = .13). The treatment group, however, demonstrated a significant improvement in accuracy (P < .02; Cohen d, effect size = 0.79). These data indicate that within the context of a CME activity, a significant improvement in diagnostic accuracy can be achieved by the use of a web-delivered, multimedia-based instructional activity supplemented by practice opportunities and feedback delivered by an artificial intelligence-driven simulation/tutor.

  11. INCLEN Diagnostic Tool for Autism Spectrum Disorder (INDT-ASD): development and validation.

    PubMed

    Juneja, Monica; Mishra, Devendra; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Tudu, Poma; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K

    2014-05-01

    To develop and validate INCLEN Diagnostic Tool for Autism Spectrum Disorder (INDT-ASD). Diagnostic test evaluation by cross sectional design. Four tertiary pediatric neurology centers in Delhi and Thiruvanthapuram, India. Children aged 2-9 years were enrolled in the study. INDT-ASD and Childhood Autism Rating Scale (CARS) were administered in a randomly decided sequence by trained psychologist, followed by an expert evaluation by DSM-IV TR diagnostic criteria (gold standard). Psychometric parameters of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. 154 children (110 boys, mean age 64.2 mo) were enrolled. The overall diagnostic accuracy (AUC=0.97, 95% CI 0.93, 0.99; P<0.001) and validity (sensitivity 98%, specificity 95%, positive predictive value 91%, negative predictive value 99%) of INDT-ASD for Autism spectrum disorder were high, taking expert diagnosis using DSM-IV-TR as gold standard. The concordance rate between the INDT-ASD and expert diagnosis for 'ASD group' was 82.52% [Cohen's k=0.89; 95% CI (0.82, 0.97); P=0.001]. The internal consistency of INDT-ASD was 0.96. The convergent validity with CARS (r = 0.73, P= 0.001) and divergent validity with Binet-Kamat Test of intelligence (r = -0.37; P=0.004) were significantly high. INDT-ASD has a 4-factor structure explaining 85.3% of the variance. INDT-ASD has high diagnostic accuracy, adequate content validity, good internal consistency high criterion validity and high to moderate convergent validity and 4-factor construct validity for diagnosis of Autistm spectrum disorder.

  12. Optimal cut points of plasma and urine neutrophil gelatinase-associated lipocalin for the prediction of acute kidney injury among critically ill adults: retrospective determination and clinical validation of a prospective multicentre study.

    PubMed

    Tecson, Kristen M; Erhardtsen, Elisabeth; Eriksen, Peter M; Gaber, A Osama; Germain, Michael; Golestaneh, Ladan; Lavoria, Maria de Los Angeles; Moore, Linda W; McCullough, Peter A

    2017-07-10

    To determine the optimal threshold of blood and urine neutrophil gelatinase-associated lipocalin (NGAL) to predict moderate to severe acute kidney injury (AKI) and persistent moderate to severe AKI lasting at least 48 consecutive hours, as defined by an adjudication panel. A multicentre prospective observational study enrolled intensive care unit (ICU) patients and recorded daily ethylenediaminetetraacetic acid (EDTA) plasma, heparin plasma and urine NGAL. We used natural log-transformed NGAL in a logistic regression model to predict stage 2/3 AKI (defined by Kidney Disease International Global Organization). We performed the same analysis using the NGAL value at the start of persistent stage 2/3 AKI. Of 245 subjects, 33 (13.5%) developed stage 2/3 AKI and 25 (10.2%) developed persistent stage 2/3 AKI. Predicting stage 2/3 AKI revealed the optimal NGAL cutoffs in EDTA plasma (142.0 ng/mL), heparin plasma (148.3 ng/mL) and urine (78.0 ng/mL) and yielded the following decision statistics: sensitivity (SN)=78.8%, specificity (SP)=73.0%, positive predictive value (PPV)=31.3%, negative predictive value (NPV)=95.7%, diagnostic accuracy (DA)=73.8% (EDTA plasma); SN=72.7%, SP=73.8%, PPV=30.4%, NPV=94.5%, DA=73.7% (heparin plasma); SN=69.7%, SP=76.8%, PPV=32.9%, NPV=94%, DA=75.8% (urine). The optimal NGAL cutoffs to predict persistent stage 2/3 AKI were similar: 148.3 ng/mL (EDTA plasma), 169.6 ng/mL (heparin plasma) and 79.0 ng/mL (urine) yielding: SN=84.0%, SP=73.5%, PPV=26.6%, NPV=97.6, DA=74.6% (EDTA plasma), SN=84%, SP=76.1%, PPV=26.8%, NPV=96.5%, DA=76.1% (heparin plasma) and SN=75%, SP=75.8%, PPV=26.1, NPV=96.4%, DA=75.7% (urine). Blood and urine NGAL predicted stage 2/3 AKI, as well as persistent 2/3 AKI in the ICU with acceptable decision statistics using a single cut point in each type of specimen. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. CompareTests-R package

    Cancer.gov

    CompareTests is an R package to estimate agreement and diagnostic accuracy statistics for two diagnostic tests when one is conducted on only a subsample of specimens. A standard test is observed on all specimens.

  14. Water-loss (intracellular) dehydration assessed using urinary tests: how well do they work? Diagnostic accuracy in older people.

    PubMed

    Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J

    2016-07-01

    Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.

  15. Accuracy in contouring of small and low contrast lesions: Comparison between diagnostic quality computed tomography scanner and computed tomography simulation scanner-A phantom study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ho, Yick Wing, E-mail: mpr@hksh.com; Wong, Wing Kei Rebecca; Yu, Siu Ki

    2012-01-01

    To evaluate the accuracy in detection of small and low-contrast regions using a high-definition diagnostic computed tomography (CT) scanner compared with a radiotherapy CT simulation scanner. A custom-made phantom with cylindrical holes of diameters ranging from 2-9 mm was filled with 9 different concentrations of contrast solution. The phantom was scanned using a 16-slice multidetector CT simulation scanner (LightSpeed RT16, General Electric Healthcare, Milwaukee, WI) and a 64-slice high-definition diagnostic CT scanner (Discovery CT750 HD, General Electric Healthcare). The low-contrast regions of interest (ROIs) were delineated automatically upon their full width at half maximum of the CT number profile inmore » Hounsfield units on a treatment planning workstation. Two conformal indexes, CI{sub in}, and CI{sub out}, were calculated to represent the percentage errors of underestimation and overestimation in the automated contours compared with their actual sizes. Summarizing the conformal indexes of different sizes and contrast concentration, the means of CI{sub in} and CI{sub out} for the CT simulation scanner were 33.7% and 60.9%, respectively, and 10.5% and 41.5% were found for the diagnostic CT scanner. The mean differences between the 2 scanners' CI{sub in} and CI{sub out} were shown to be significant with p < 0.001. A descending trend of the index values was observed as the ROI size increases for both scanners, which indicates an improved accuracy when the ROI size increases, whereas no observable trend was found in the contouring accuracy with respect to the contrast levels in this study. Images acquired by the diagnostic CT scanner allow higher accuracy on size estimation compared with the CT simulation scanner in this study. We recommend using a diagnostic CT scanner to scan patients with small lesions (<1 cm in diameter) for radiotherapy treatment planning, especially for those pending for stereotactic radiosurgery in which accurate delineation of small-sized, low-contrast regions is important for dose calculation.« less

  16. A systematic evaluation of prevalence and diagnostic accuracy of sacroiliac joint interventions.

    PubMed

    Simopoulos, Thomas T; Manchikanti, Laxmaiah; Singh, Vijay; Gupta, Sanjeeva; Hameed, Haroon; Diwan, Sudhir; Cohen, Steven P

    2012-01-01

    The contributions of the sacroiliac joint to low back and lower extremity pain have been a subject of considerable debate and research. It is generally accepted that 10% to 25% of patients with persistent mechanical low back pain below L5 have pain secondary to sacroiliac joint pathology. However, no single historical, physical exam, or radiological feature can definitively establish a diagnosis of sacroiliac joint pain. Based on present knowledge, a proper diagnosis can only be made using controlled diagnostic blocks. The diagnosis and treatment of sacroiliac joint pain continue to be characterized by wide variability and a paucity of the literature. To evaluate the accuracy of diagnostic sacroiliac joint interventions. A systematic review of diagnostic sacroiliac joint interventions. Methodological quality assessment of included studies was performed using Quality Appraisal of Reliability Studies (QAREL). Only diagnostic accuracy studies meeting at least 50% of the designated inclusion criteria were utilized for analysis. Studies scoring less than 50% are presented descriptively and analyzed critically. The level of evidence was classified as good, fair, or poor based on the quality of evidence developed by the United States Preventive Services Task Force (USPSTF). Data sources included relevant literature identified through searches of PubMed and EMBASE from 1966 to December 2011, and manual searches of the bibliographies of known primary and review articles. In this evaluation we utilized controlled local anesthetic blocks using at least 50% pain relief as the reference standard. The evidence is good for the diagnosis of sacroiliac joint pain utilizing controlled comparative local anesthetic blocks. The prevalence of sacroiliac joint pain is estimated to range between 10% and 62% based on the setting; however, the majority of analyzed studies suggest a point prevalence of around 25%, with a false-positive rate for uncontrolled blocks of approximately 20%. The evidence for provocative testing to diagnose sacroiliac joint pain was fair. The evidence for the diagnostic accuracy of imaging is limited. The limitations of this systematic review include a paucity of literature, variations in technique, and variable criterion standards for the diagnosis of sacroiliac joint pain. Based on this systematic review, the evidence for the diagnostic accuracy of sacroiliac joint injections is good, the evidence for provocation maneuvers is fair, and evidence for imaging is limited.

  17. Does training improve diagnostic accuracy and inter-rater agreement in applying the Berlin radiographic definition of acute respiratory distress syndrome? A multicenter prospective study.

    PubMed

    Peng, Jin-Min; Qian, Chuan-Yun; Yu, Xiang-You; Zhao, Ming-Yan; Li, Shu-Sheng; Ma, Xiao-Chun; Kang, Yan; Zhou, Fa-Chun; He, Zhen-Yang; Qin, Tie-He; Yin, Yong-Jie; Jiang, Li; Hu, Zhen-Jie; Sun, Ren-Hua; Lin, Jian-Dong; Li, Tong; Wu, Da-Wei; An, You-Zhong; Ai, Yu-Hang; Zhou, Li-Hua; Cao, Xiang-Yuan; Zhang, Xi-Jing; Sun, Rong-Qing; Chen, Er-Zhen; Du, Bin

    2017-01-20

    Poor inter-rater reliability in chest radiograph interpretation has been reported in the context of acute respiratory distress syndrome (ARDS), although not for the Berlin definition of ARDS. We sought to examine the effect of training material on the accuracy and consistency of intensivists' chest radiograph interpretations for ARDS diagnosis. We conducted a rater agreement study in which 286 intensivists (residents 41.3%, junior attending physicians 35.3%, and senior attending physician 23.4%) independently reviewed the same 12 chest radiographs developed by the ARDS Definition Task Force ("the panel") before and after training. Radiographic diagnoses by the panel were classified into the consistent (n = 4), equivocal (n = 4), and inconsistent (n = 4) categories and were used as a reference. The 1.5-hour training course attended by all 286 intensivists included introduction of the diagnostic rationale, and a subsequent in-depth discussion to reach consensus for all 12 radiographs. Overall diagnostic accuracy, which was defined as the percentage of chest radiographs that were interpreted correctly, improved but remained poor after training (42.0 ± 14.8% before training vs. 55.3 ± 23.4% after training, p < 0.001). Diagnostic sensitivity and specificity improved after training for all diagnostic categories (p < 0.001), with the exception of specificity for the equivocal category (p = 0.883). Diagnostic accuracy was higher for the consistent category than for the inconsistent and equivocal categories (p < 0.001). Comparisons of pre-training and post-training results revealed that inter-rater agreement was poor and did not improve after training, as assessed by overall agreement (0.450 ± 0.406 vs. 0.461 ± 0.575, p = 0.792), Fleiss's kappa (0.133 ± 0.575 vs. 0.178 ± 0.710, p = 0.405), and intraclass correlation coefficient (ICC; 0.219 vs. 0.276, p = 0.470). The radiographic diagnostic accuracy and inter-rater agreement were poor when the Berlin radiographic definition was used, and were not significantly improved by the training set of chest radiographs developed by the ARDS Definition Task Force. The study was registered at ClinicalTrials.gov (registration number NCT01704066 ) on 6 October 2012.

  18. Quantitative Myocardial Perfusion Imaging Versus Visual Analysis in Diagnosing Myocardial Ischemia: A CE-MARC Substudy.

    PubMed

    Biglands, John D; Ibraheem, Montasir; Magee, Derek R; Radjenovic, Aleksandra; Plein, Sven; Greenwood, John P

    2018-05-01

    This study sought to compare the diagnostic accuracy of visual and quantitative analyses of myocardial perfusion cardiovascular magnetic resonance against a reference standard of quantitative coronary angiography. Visual analysis of perfusion cardiovascular magnetic resonance studies for assessing myocardial perfusion has been shown to have high diagnostic accuracy for coronary artery disease. However, only a few small studies have assessed the diagnostic accuracy of quantitative myocardial perfusion. This retrospective study included 128 patients randomly selected from the CE-MARC (Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease) study population such that the distribution of risk factors and disease status was proportionate to the full population. Visual analysis results of cardiovascular magnetic resonance perfusion images, by consensus of 2 expert readers, were taken from the original study reports. Quantitative myocardial blood flow estimates were obtained using Fermi-constrained deconvolution. The reference standard for myocardial ischemia was a quantitative coronary x-ray angiogram stenosis severity of ≥70% diameter in any coronary artery of >2 mm diameter, or ≥50% in the left main stem. Diagnostic performance was calculated using receiver-operating characteristic curve analysis. The area under the curve for visual analysis was 0.88 (95% confidence interval: 0.81 to 0.95) with a sensitivity of 81.0% (95% confidence interval: 69.1% to 92.8%) and specificity of 86.0% (95% confidence interval: 78.7% to 93.4%). For quantitative stress myocardial blood flow the area under the curve was 0.89 (95% confidence interval: 0.83 to 0.96) with a sensitivity of 87.5% (95% confidence interval: 77.3% to 97.7%) and specificity of 84.5% (95% confidence interval: 76.8% to 92.3%). There was no statistically significant difference between the diagnostic performance of quantitative and visual analyses (p = 0.72). Incorporating rest myocardial blood flow values to generate a myocardial perfusion reserve did not significantly increase the quantitative analysis area under the curve (p = 0.79). Quantitative perfusion has a high diagnostic accuracy for detecting coronary artery disease but is not superior to visual analysis. The incorporation of rest perfusion imaging does not improve diagnostic accuracy in quantitative perfusion analysis. Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Diagnostic accuracy of different body weight and height-based definitions of childhood obesity in identifying overfat among Chinese children and adolescents: a cross-sectional study.

    PubMed

    Wang, Lin; Hui, Stanley Sai-chuen

    2015-08-20

    Various body weight and height-based references are used to define obese children and adolescents. However, no study investigating the diagnostic accuracies of the definitions of obesity and overweight in Hong Kong Chinese children and adolescents has been conducted. The current study aims to investigate the diagnostic accuracy of BMI-based definitions and 1993 HK reference in screening excess body fat among Hong Kong Chinese children and adolescents. A total of 2,134 participants (1,135 boys and 999 girls) were recruited from local schools. The foot-to-foot BIA scale was applied to assess %BF using standard methods. The criterion of childhood obesity (i.e., overfat) was defined as over 25 %BF for boys and over 30 %BF for girls. Childhood obesity was also determined from four BMI-based references and the 1993 HK reference. The diagnostic accuracy of these existing definitions for childhood obesity in screening excess body fat was evaluated using diagnostic indices. Overall, %BF was significantly correlated with anthropometry measurements in both genders (in boys, r = 0.747 for BMI 0.766 for PWH; in girls, r = 0.930 for BMI 0.851 for PWH). The prevalence rates of overweight and obesity determined by BMI-based references were similar with the prevalence rates of obesity in the 1993 HK reference in both genders. All definitions for childhood obesity showed low sensitivity (in boys, 0.325-0.761; in girls, 0.128-0.588) in detecting overfat. Specificities were high for cut-offs among all definitions for childhood obesity (in boys, 0.862-0.980; in girls, 0.973-0.998). In conclusion, prevalence rates of childhood obesity or overweight varied widely according to the diagnostic references applied. The diagnostic performance for weight and height-based references for obesity is poorer than expected for both genders among Hong Kong Chinese children and adolescents. In order to improve the diagnosis accuracy of childhood obesity, either cut-off values of body weight and height-based definitions of childhood obesity should be revised to increase the sensitivity or the possibility of using other indirect methods of estimating the %BF should be explored.

  20. Rapid detection of health-care-associated bloodstream infection in critical care using multipathogen real-time polymerase chain reaction technology: a diagnostic accuracy study and systematic review.

    PubMed

    Warhurst, Geoffrey; Dunn, Graham; Chadwick, Paul; Blackwood, Bronagh; McAuley, Daniel; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Bentley, Andrew; Young, Duncan; Carlson, Gordon L; Dark, Paul

    2015-05-01

    There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. Critical care departments within NHS hospitals in the north-west of England. Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4-16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error. The systematic review is registered as PROSPERO CRD42011001289. The National Institute for Health Research Health Technology Assessment programme. Professor Daniel McAuley and Professor Gavin D Perkins contributed to the systematic review through their funded roles as codirectors of the Intensive Care Foundation (UK).

  1. Piloted simulation of a ground-based time-control concept for air traffic control

    NASA Technical Reports Server (NTRS)

    Davis, Thomas J.; Green, Steven M.

    1989-01-01

    A concept for aiding air traffic controllers in efficiently spacing traffic and meeting scheduled arrival times at a metering fix was developed and tested in a real time simulation. The automation aid, referred to as the ground based 4-D descent advisor (DA), is based on accurate models of aircraft performance and weather conditions. The DA generates suggested clearances, including both top-of-descent-point and speed-profile data, for one or more aircraft in order to achieve specific time or distance separation objectives. The DA algorithm is used by the air traffic controller to resolve conflicts and issue advisories to arrival aircraft. A joint simulation was conducted using a piloted simulator and an advanced concept air traffic control simulation to study the acceptability and accuracy of the DA automation aid from both the pilot's and the air traffic controller's perspectives. The results of the piloted simulation are examined. In the piloted simulation, airline crews executed controller issued descent advisories along standard curved path arrival routes, and were able to achieve an arrival time precision of + or - 20 sec at the metering fix. An analysis of errors generated in turns resulted in further enhancements of the algorithm to improve the predictive accuracy. Evaluations by pilots indicate general support for the concept and provide specific recommendations for improvement.

  2. Diagnostic accuracy of a bayesian latent group analysis for the detection of malingering-related poor effort.

    PubMed

    Ortega, Alonso; Labrenz, Stephan; Markowitsch, Hans J; Piefke, Martina

    2013-01-01

    In the last decade, different statistical techniques have been introduced to improve assessment of malingering-related poor effort. In this context, we have recently shown preliminary evidence that a Bayesian latent group model may help to optimize classification accuracy using a simulation research design. In the present study, we conducted two analyses. Firstly, we evaluated how accurately this Bayesian approach can distinguish between participants answering in an honest way (honest response group) and participants feigning cognitive impairment (experimental malingering group). Secondly, we tested the accuracy of our model in the differentiation between patients who had real cognitive deficits (cognitively impaired group) and participants who belonged to the experimental malingering group. All Bayesian analyses were conducted using the raw scores of a visual recognition forced-choice task (2AFC), the Test of Memory Malingering (TOMM, Trial 2), and the Word Memory Test (WMT, primary effort subtests). The first analysis showed 100% accuracy for the Bayesian model in distinguishing participants of both groups with all effort measures. The second analysis showed outstanding overall accuracy of the Bayesian model when estimates were obtained from the 2AFC and the TOMM raw scores. Diagnostic accuracy of the Bayesian model diminished when using the WMT total raw scores. Despite, overall diagnostic accuracy can still be considered excellent. The most plausible explanation for this decrement is the low performance in verbal recognition and fluency tasks of some patients of the cognitively impaired group. Additionally, the Bayesian model provides individual estimates, p(zi |D), of examinees' effort levels. In conclusion, both high classification accuracy levels and Bayesian individual estimates of effort may be very useful for clinicians when assessing for effort in medico-legal settings.

  3. Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations.

    PubMed

    Shokri, Abbas; Eskandarloo, Amir; Norouzi, Marouf; Poorolajal, Jalal; Majidi, Gelareh; Aliyaly, Alireza

    2018-03-01

    This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chi-square test was used to assess the nominal variables. In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D. The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

  4. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    PubMed Central

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant (P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications. PMID:27239115

  5. Comparison of computer systems and ranking criteria for automatic melanoma detection in dermoscopic images.

    PubMed

    Møllersen, Kajsa; Zortea, Maciel; Schopf, Thomas R; Kirchesch, Herbert; Godtliebsen, Fred

    2017-01-01

    Melanoma is the deadliest form of skin cancer, and early detection is crucial for patient survival. Computer systems can assist in melanoma detection, but are not widespread in clinical practice. In 2016, an open challenge in classification of dermoscopic images of skin lesions was announced. A training set of 900 images with corresponding class labels and semi-automatic/manual segmentation masks was released for the challenge. An independent test set of 379 images, of which 75 were of melanomas, was used to rank the participants. This article demonstrates the impact of ranking criteria, segmentation method and classifier, and highlights the clinical perspective. We compare five different measures for diagnostic accuracy by analysing the resulting ranking of the computer systems in the challenge. Choice of performance measure had great impact on the ranking. Systems that were ranked among the top three for one measure, dropped to the bottom half when changing performance measure. Nevus Doctor, a computer system previously developed by the authors, was used to participate in the challenge, and investigate the impact of segmentation and classifier. The diagnostic accuracy when using an automatic versus the semi-automatic/manual segmentation is investigated. The unexpected small impact of segmentation method suggests that improvements of the automatic segmentation method w.r.t. resemblance to semi-automatic/manual segmentation will not improve diagnostic accuracy substantially. A small set of similar classification algorithms are used to investigate the impact of classifier on the diagnostic accuracy. The variability in diagnostic accuracy for different classifier algorithms was larger than the variability for segmentation methods, and suggests a focus for future investigations. From a clinical perspective, the misclassification of a melanoma as benign has far greater cost than the misclassification of a benign lesion. For computer systems to have clinical impact, their performance should be ranked by a high-sensitivity measure.

  6. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants: comparison with transthoracic echocardiography.

    PubMed

    Goo, Hyun Woo

    2018-02-01

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants.

  7. Multicenter Evaluation Of Coronary Dual-Source CT angiography in patients with intermediate Risk of Coronary Artery Stenoses (MEDIC): study design and rationale.

    PubMed

    Marwan, Mohamed; Hausleiter, Jörg; Abbara, Suhny; Hoffmann, Udo; Becker, Christoph; Ovrehus, Kristian; Ropers, Dieter; Bathina, Ravi; Berman, Dan; Anders, Katharina; Uder, Michael; Meave, Aloha; Alexánderson, Erick; Achenbach, Stephan

    2014-01-01

    The diagnostic performance of multidetector row CT to detect coronary artery stenosis has been evaluated in numerous single-center studies, with only limited data from large cohorts with low-to-intermediate likelihood of coronary disease and in multicenter trials. The Multicenter Evaluation of Coronary Dual-Source CT Angiography in Patients with Intermediate Risk of Coronary Artery Stenoses (MEDIC) trial determines the accuracy of dual-source CT (DSCT) to identify persons with at least 1 coronary artery stenosis among patients with low-to-intermediate pretest likelihood of disease. The MEDIC trial was designed as a prospective, multicenter, international trial to evaluate the diagnostic performance of DSCT for the detection of coronary artery stenosis compared with invasive coronary angiography. The study includes 8 sites in Germany, India, Mexico, the United States, and Denmark. The study population comprises patients referred for a diagnostic coronary angiogram because of suspected coronary artery disease with an intermediate pretest likelihood as determined by sex, age, and symptoms. All evaluations are performed by blinded core laboratory readers. The primary outcome of the MEDIC trial is the accuracy of DSCT to identify the presence of coronary artery stenoses with a luminal diameter narrowing of 50% or more on a per-vessel basis. Secondary outcome parameters include per-patient and per-segment diagnostic accuracy for 50% stenoses and accuracy to identify stenoses of 70% or more. Furthermore, secondary outcome parameters include the influence of heart rate, Agatston score, body weight, body mass index, image quality, and diagnostic confidence on the accuracy to detect coronary artery stenoses >50% on a per-vessel basis. The results of the MEDIC trial will assess the clinical utility of coronary CT angiography in the evaluation of patients with intermediate pretest likelihood of coronary artery disease. Copyright © 2014 Society of Cardiovascular Computed Tomography. All rights reserved.

  8. Which are the most useful scales for predicting repeat self-harm? A systematic review evaluating risk scales using measures of diagnostic accuracy

    PubMed Central

    Quinlivan, L; Cooper, J; Davies, L; Hawton, K; Gunnell, D; Kapur, N

    2016-01-01

    Objectives The aims of this review were to calculate the diagnostic accuracy statistics of risk scales following self-harm and consider which might be the most useful scales in clinical practice. Design Systematic review. Methods We based our search terms on those used in the systematic reviews carried out for the National Institute for Health and Care Excellence self-harm guidelines (2012) and evidence update (2013), and updated the searches through to February 2015 (CINAHL, EMBASE, MEDLINE, and PsychINFO). Methodological quality was assessed and three reviewers extracted data independently. We limited our analysis to cohort studies in adults using the outcome of repeat self-harm or attempted suicide. We calculated diagnostic accuracy statistics including measures of global accuracy. Statistical pooling was not possible due to heterogeneity. Results The eight papers included in the final analysis varied widely according to methodological quality and the content of scales employed. Overall, sensitivity of scales ranged from 6% (95% CI 5% to 6%) to 97% (CI 95% 94% to 98%). The positive predictive value (PPV) ranged from 5% (95% CI 3% to 9%) to 84% (95% CI 80% to 87%). The diagnostic OR ranged from 1.01 (95% CI 0.434 to 2.5) to 16.3 (95%CI 12.5 to 21.4). Scales with high sensitivity tended to have low PPVs. Conclusions It is difficult to be certain which, if any, are the most useful scales for self-harm risk assessment. No scales perform sufficiently well so as to be recommended for routine clinical use. Further robust prospective studies are warranted to evaluate risk scales following an episode of self-harm. Diagnostic accuracy statistics should be considered in relation to the specific service needs, and scales should only be used as an adjunct to assessment. PMID:26873046

  9. Accuracy of LightCycler(R) SeptiFast for the detection and identification of pathogens in the blood of patients with suspected sepsis: a systematic review protocol.

    PubMed

    Dark, Paul; Wilson, Claire; Blackwood, Bronagh; McAuley, Danny F; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Warhurst, Geoffrey

    2012-01-01

    Background There is growing interest in the potential utility of molecular diagnostics in improving the detection of life-threatening infection (sepsis). LightCycler® SeptiFast is a multipathogen probe-based real-time PCR system targeting DNA sequences of bacteria and fungi present in blood samples within a few hours. We report here the protocol of the first systematic review of published clinical diagnostic accuracy studies of this technology when compared with blood culture in the setting of suspected sepsis. Methods/design Data sources: the Cochrane Database of Systematic Reviews, the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA), the NHS Economic Evaluation Database (NHSEED), The Cochrane Library, MEDLINE, EMBASE, ISI Web of Science, BIOSIS Previews, MEDION and the Aggressive Research Intelligence Facility Database (ARIF). diagnostic accuracy studies that compare the real-time PCR technology with standard culture results performed on a patient's blood sample during the management of sepsis. three reviewers, working independently, will determine the level of evidence, methodological quality and a standard data set relating to demographics and diagnostic accuracy metrics for each study. Statistical analysis/data synthesis: heterogeneity of studies will be investigated using a coupled forest plot of sensitivity and specificity and a scatter plot in Receiver Operator Characteristic (ROC) space. Bivariate model method will be used to estimate summary sensitivity and specificity. The authors will investigate reporting biases using funnel plots based on effective sample size and regression tests of asymmetry. Subgroup analyses are planned for adults, children and infection setting (hospital vs community) if sufficient data are uncovered. Dissemination Recommendations will be made to the Department of Health (as part of an open-access HTA report) as to whether the real-time PCR technology has sufficient clinical diagnostic accuracy potential to move forward to efficacy testing during the provision of routine clinical care. Registration PROSPERO-NIHR Prospective Register of Systematic Reviews (CRD42011001289).

  10. Significance of serum and bile tumor markers in the diagnostic approach of patients with malignant pancreatobiliary disease.

    PubMed

    Natsios, Athanasios; Vezakis, Antonios; Kaparos, Georgios; Fragulidis, Georgios; Karakostas, Nikolaos; Kouskouni, Evangelia; Logothetis, Emmanouil; Polydorou, Andreas

    2015-01-01

    Serum and bile tumor markers are under intense scrutiny for the diagnosis of malignant disease. The purpose of our study was to report the usefulness of serum and bile tumor markers for the discrimination between benign and malignant pancreatobiliary diseases. Between March 2010 and May 2013, 95 patients with obstructive jaundice or history of biliary obstruction, were included in the study. During ERCP, bile samples were obtained for measurement of tumor markers CEA, CA19- 9, CA125, CA72-4 and CA242. Serum samples were taken before ERCP for the same measurements. The patients were divided into two groups: patients with malignant disease and patients with benign disease. Serum tumor marker levels were significantly higher in patients with malignant disease. Serum CA242 and CA19-9 exhibited the highest diagnostic accuracy (76.8% and 73.7%, respectively). CA125 and CA72-4 levels in bile samples were significantly higher in patients with malignant disease. Bile CA125, CEA and CA72-4 achieved the best diagnostic accuracy (69, 65 and 65), respectively). The combined detection of CA19-9, CA242 in serum and CA125, CA72-4 in bile along with total bilirubin levels, showed the best diagnostic accuracy (81%). Serum and bile tumor markers, when studied alone, lack the diagnostic yield to discriminate benign from malignant pancreatobiliary diseases. In cases of diagnostic dilemmas the combination of serum and bile markers might be helpful.

  11. Elicitation of neurological knowledge with argument-based machine learning.

    PubMed

    Groznik, Vida; Guid, Matej; Sadikov, Aleksander; Možina, Martin; Georgiev, Dejan; Kragelj, Veronika; Ribarič, Samo; Pirtošek, Zvezdan; Bratko, Ivan

    2013-02-01

    The paper describes the use of expert's knowledge in practice and the efficiency of a recently developed technique called argument-based machine learning (ABML) in the knowledge elicitation process. We are developing a neurological decision support system to help the neurologists differentiate between three types of tremors: Parkinsonian, essential, and mixed tremor (comorbidity). The system is intended to act as a second opinion for the neurologists, and most importantly to help them reduce the number of patients in the "gray area" that require a very costly further examination (DaTSCAN). We strive to elicit comprehensible and medically meaningful knowledge in such a way that it does not come at the cost of diagnostic accuracy. To alleviate the difficult problem of knowledge elicitation from data and domain experts, we used ABML. ABML guides the expert to explain critical special cases which cannot be handled automatically by machine learning. This very efficiently reduces the expert's workload, and combines expert's knowledge with learning data. 122 patients were enrolled into the study. The classification accuracy of the final model was 91%. Equally important, the initial and the final models were also evaluated for their comprehensibility by the neurologists. All 13 rules of the final model were deemed as appropriate to be able to support its decisions with good explanations. The paper demonstrates ABML's advantage in combining machine learning and expert knowledge. The accuracy of the system is very high with respect to the current state-of-the-art in clinical practice, and the system's knowledge base is assessed to be very consistent from a medical point of view. This opens up the possibility to use the system also as a teaching tool. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Fundus autofluorescence imaging: systematic review of test accuracy for the diagnosis and monitoring of retinal conditions.

    PubMed

    Frampton, G K; Kalita, N; Payne, L; Colquitt, J L; Loveman, E; Downes, S M; Lotery, A J

    2017-07-01

    We conducted a systematic review of the accuracy of fundus autofluorescence (FAF) imaging for diagnosing and monitoring retinal conditions. Searches in November 2014 identified English language references. Sources included MEDLINE, EMBASE, the Cochrane Library, Web of Science, and MEDION databases; reference lists of retrieved studies; and internet pages of relevant organisations, meetings, and trial registries. For inclusion, studies had to report FAF imaging accuracy quantitatively. Studies were critically appraised using QUADAS risk of bias criteria. Two reviewers conducted all review steps. From 2240 unique references identified, eight primary research studies met the inclusion criteria. These investigated diagnostic accuracy of FAF imaging for choroidal neovascularisation (one study), reticular pseudodrusen (three studies), cystoid macular oedema (two studies), and diabetic macular oedema (two studies). Diagnostic sensitivity of FAF imaging ranged from 32 to 100% and specificity from 34 to 100%. However, owing to methodological limitations, including high and/or unclear risks of bias, none of these studies provides conclusive evidence of the diagnostic accuracy of FAF imaging. Study heterogeneity precluded meta-analysis. In most studies, the patient spectrum was not reflective of those who would present in clinical practice and no studies adequately reported whether FAF images were interpreted consistently. No studies of monitoring accuracy were identified. An update in October 2016, based on MEDLINE and internet searches, identified four new studies but did not alter our conclusions. Robust quantitative evidence on the accuracy of FAF imaging and how FAF images are interpreted is lacking. We provide recommendations to address this.

  13. Simultaneous data pre-processing and SVM classification model selection based on a parallel genetic algorithm applied to spectroscopic data of olive oils.

    PubMed

    Devos, Olivier; Downey, Gerard; Duponchel, Ludovic

    2014-04-01

    Classification is an important task in chemometrics. For several years now, support vector machines (SVMs) have proven to be powerful for infrared spectral data classification. However such methods require optimisation of parameters in order to control the risk of overfitting and the complexity of the boundary. Furthermore, it is established that the prediction ability of classification models can be improved using pre-processing in order to remove unwanted variance in the spectra. In this paper we propose a new methodology based on genetic algorithm (GA) for the simultaneous optimisation of SVM parameters and pre-processing (GENOPT-SVM). The method has been tested for the discrimination of the geographical origin of Italian olive oil (Ligurian and non-Ligurian) on the basis of near infrared (NIR) or mid infrared (FTIR) spectra. Different classification models (PLS-DA, SVM with mean centre data, GENOPT-SVM) have been tested and statistically compared using McNemar's statistical test. For the two datasets, SVM with optimised pre-processing give models with higher accuracy than the one obtained with PLS-DA on pre-processed data. In the case of the NIR dataset, most of this accuracy improvement (86.3% compared with 82.8% for PLS-DA) occurred using only a single pre-processing step. For the FTIR dataset, three optimised pre-processing steps are required to obtain SVM model with significant accuracy improvement (82.2%) compared to the one obtained with PLS-DA (78.6%). Furthermore, this study demonstrates that even SVM models have to be developed on the basis of well-corrected spectral data in order to obtain higher classification rates. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Predicting acute uncomplicated urinary tract infection in women: a systematic review of the diagnostic accuracy of symptoms and signs

    PubMed Central

    2010-01-01

    Background Acute urinary tract infections (UTI) are one of the most common bacterial infections among women presenting to primary care. However, there is a lack of consensus regarding the optimal reference standard threshold for diagnosing UTI. The objective of this systematic review is to determine the diagnostic accuracy of symptoms and signs in women presenting with suspected UTI, across three different reference standards (102 or 103 or 105 CFU/ml). We also examine the diagnostic value of individual symptoms and signs combined with dipstick test results in terms of clinical decision making. Methods Searches were performed through PubMed (1966 to April 2010), EMBASE (1973 to April 2010), Cochrane library (1973 to April 2010), Google scholar and reference checking. Studies that assessed the diagnostic accuracy of symptoms and signs of an uncomplicated UTI using a urine culture from a clean-catch or catherised urine specimen as the reference standard, with a reference standard of at least ≥ 102 CFU/ml were included. Synthesised data from a high quality systematic review were used regarding dipstick results. Studies were combined using a bivariate random effects model. Results Sixteen studies incorporating 3,711 patients are included. The weighted prior probability of UTI varies across diagnostic threshold, 65.1% at ≥ 102 CFU/ml; 55.4% at ≥ 103 CFU/ml and 44.8% at ≥ 102 CFU/ml ≥ 105 CFU/ml. Six symptoms are identified as useful diagnostic symptoms when a threshold of ≥ 102 CFU/ml is the reference standard. Presence of dysuria (+LR 1.30 95% CI 1.20-1.41), frequency (+LR 1.10 95% CI 1.04-1.16), hematuria (+LR 1.72 95%CI 1.30-2.27), nocturia (+LR 1.30 95% CI 1.08-1.56) and urgency (+LR 1.22 95% CI 1.11-1.34) all increase the probability of UTI. The presence of vaginal discharge (+LR 0.65 95% CI 0.51-0.83) decreases the probability of UTI. Presence of hematuria has the highest diagnostic utility, raising the post-test probability of UTI to 75.8% at ≥ 102 CFU/ml and 67.4% at ≥ 103 CFU/ml. Probability of UTI increases to 93.3% and 90.1% at ≥ 102 CFU/ml and ≥ 103 CFU/ml respectively when presence of hematuria is combined with a positive dipstick result for nitrites. Subgroup analysis shows improved diagnostic accuracy using lower reference standards ≥ 102 CFU/ml and ≥ 103 CFU/ml. Conclusions Individual symptoms and signs have a modest ability to raise the pretest-risk of UTI. Diagnostic accuracy improves considerably when combined with dipstick tests particularly tests for nitrites. PMID:20969801

  15. Predicting acute uncomplicated urinary tract infection in women: a systematic review of the diagnostic accuracy of symptoms and signs.

    PubMed

    Giesen, Leonie G M; Cousins, Gráinne; Dimitrov, Borislav D; van de Laar, Floris A; Fahey, Tom

    2010-10-24

    Acute urinary tract infections (UTI) are one of the most common bacterial infections among women presenting to primary care. However, there is a lack of consensus regarding the optimal reference standard threshold for diagnosing UTI. The objective of this systematic review is to determine the diagnostic accuracy of symptoms and signs in women presenting with suspected UTI, across three different reference standards (10(2) or 10(3) or 10(5) CFU/ml). We also examine the diagnostic value of individual symptoms and signs combined with dipstick test results in terms of clinical decision making. Searches were performed through PubMed (1966 to April 2010), EMBASE (1973 to April 2010), Cochrane library (1973 to April 2010), Google scholar and reference checking.Studies that assessed the diagnostic accuracy of symptoms and signs of an uncomplicated UTI using a urine culture from a clean-catch or catherised urine specimen as the reference standard, with a reference standard of at least ≥ 10(2) CFU/ml were included. Synthesised data from a high quality systematic review were used regarding dipstick results. Studies were combined using a bivariate random effects model. Sixteen studies incorporating 3,711 patients are included. The weighted prior probability of UTI varies across diagnostic threshold, 65.1% at ≥ 10(2) CFU/ml; 55.4% at ≥ 10(3) CFU/ml and 44.8% at ≥ 10(2) CFU/ml ≥ 10(5) CFU/ml. Six symptoms are identified as useful diagnostic symptoms when a threshold of ≥ 10(2) CFU/ml is the reference standard. Presence of dysuria (+LR 1.30 95% CI 1.20-1.41), frequency (+LR 1.10 95% CI 1.04-1.16), hematuria (+LR 1.72 95%CI 1.30-2.27), nocturia (+LR 1.30 95% CI 1.08-1.56) and urgency (+LR 1.22 95% CI 1.11-1.34) all increase the probability of UTI. The presence of vaginal discharge (+LR 0.65 95% CI 0.51-0.83) decreases the probability of UTI. Presence of hematuria has the highest diagnostic utility, raising the post-test probability of UTI to 75.8% at ≥ 10(2) CFU/ml and 67.4% at ≥ 10(3) CFU/ml. Probability of UTI increases to 93.3% and 90.1% at ≥ 10(2) CFU/ml and ≥ 10(3) CFU/ml respectively when presence of hematuria is combined with a positive dipstick result for nitrites. Subgroup analysis shows improved diagnostic accuracy using lower reference standards ≥ 10(2) CFU/ml and ≥ 10(3) CFU/ml. Individual symptoms and signs have a modest ability to raise the pretest-risk of UTI. Diagnostic accuracy improves considerably when combined with dipstick tests particularly tests for nitrites.

  16. Synergistic electron transfer effect-based signal amplification strategy for the ultrasensitive detection of dopamine.

    PubMed

    Lu, Qiujun; Chen, Xiaogen; Liu, Dan; Wu, Cuiyan; Liu, Meiling; Li, Haitao; Zhang, Youyu; Yao, Shouzhuo

    2018-05-15

    The selective and sensitive detection of dopamine (DA) is of great significance for the identification of schizophrenia, Huntington's disease, and Parkinson's disease from the perspective of molecular diagnostics. So far, most of DA fluorescence sensors are based on the electron transfer from the fluorescence nanomaterials to DA-quinone. However, the limited electron transfer ability of the DA-quinone affects the level of detection sensitivity of these sensors. In this work, based on the DA can reduce Ag + into AgNPs followed by oxidized to DA-quinone, we developed a novel silicon nanoparticles-based electron transfer fluorescent sensor for the detection of DA. As electron transfer acceptor, the AgNPs and DA-quinone can quench the fluorescence of silicon nanoparticles effectively through the synergistic electron transfer effect. Compared with traditional fluorescence DA sensors, the proposed synergistic electron transfer-based sensor improves the detection sensitivity to a great extent (at least 10-fold improvement). The proposed sensor shows a low detection limit of DA, which is as low as 0.1 nM under the optimal conditions. This sensor has potential applicability for the detection of DA in practical sample. This work has been demonstrated to contribute to a substantial improvement in the sensitivity of the sensors. It also gives new insight into design electron transfer-based sensors. Copyright © 2018. Published by Elsevier B.V.

  17. The role of molecular diagnostic testing in the management of thyroid nodules.

    PubMed

    Moore, Maureen D; Panjwani, Suraj; Gray, Katherine D; Finnerty, Brendan M; Zarnegar, Rasa; Fahey, Thomas J

    2017-06-01

    Fine needle aspiration (FNA) with cytologic examination remains the standard of care for investigation of thyroid nodules. However, as many as 30% of FNA samples are cytologically indeterminate for malignancy, which confounds clinical management. To reduce the burden of repeat diagnostic testing and unnecessary surgery, there has been extensive investigation into molecular markers that can be detected on FNA specimens to more accurately stratify a patient's risk of malignancy. Areas covered: In this review, the authors discuss recent evidence and progress in molecular markers used in the diagnosis of thyroid cancer highlighting somatic gene alterations, molecular technologies and microRNA analysis. Expert commentary: The goal of molecular markers is to improve diagnostic accuracy and aid clinicians in the preoperative management of thyroid lesions. Modalities such as direct mutation analysis, mRNA gene expression profiling, next-generation sequencing, and miRNA expression profiling have been explored to improve the diagnostic accuracy of thyroid nodule FNA. Although no perfect test has been discovered, molecular diagnostic testing has revolutionized the management of thyroid nodules.

  18. Conservation of Mannan Synthesis in Fungi of the Zygomycota and Ascomycota Reveals a Broad Diagnostic Target

    PubMed Central

    Hubbard, Breeana; Kvam, Alexander J.; Gates-Hollingsworth, Marcellene; Green, Heather R.; Soukup, Eric; Limper, Andrew H.; Kozel, Thomas R.

    2018-01-01

    ABSTRACT Ascomycetes and zygomycetes account for the majority of (i) fungi responsible for cutaneous, subcutaneous, and invasive human fungal infections, (ii) plant fungal pathogens, (iii) fungi that threaten global biodiversity, (iv) fungal agents of agricultural spoilage, and (v) fungi in water-damaged buildings. Rapid recognition of fungal infection (or contamination) enables early treatment (or remediation). A bioinformatics search found homologues of Saccharomyces cerevisiae Mnn9p present in members of the Zygomycota and Ascomycota phyla and absent in members of the Chytridiomycota and Basidiomycota. Mnn9p is a component of the yeast mannan polymerization complex and is necessary for α-1,6 mannan production. A monoclonal antibody (2DA6) was produced that was reactive with purified mannans of Mucor, Rhizopus, Aspergillus, Fusarium, and Candida species. Experimentation using a 2DA6 antigen capture enzyme-linked immunosorbent assay (ELISA) and extracts of fungi from the four phyla found agreement between the presence or absence of Mnn9p homologues and production or lack of production of mannan reactive with 2DA6. Studies of cell extracts from yeast mannan mutants identified α-1,6 mannan as the epitope recognized by 2DA6. To translate this finding into a point-of-use diagnostic, a 2DA6 lateral flow immunoassay was constructed that detected mannan in (i) extracts of dermatophytes and fungi that produce trauma-related infection and (ii) tissue from plants infected with Grosmannia clavigera or Sclerotium cepivorum. These studies (i) revealed that the conservation of α-1,6-linked mannan in fungi of the Zygomycota and Ascomycota can be exploited as a broad diagnostic target and (ii) have provided a means to detect that target in an immunoassay platform that is well suited for clinic or field use. IMPORTANCE A key question asked when faced with an infection, an infestation, or environmental damage is whether it is a fungus. Identification of fungi as the cause of the problem can lead to remediation or treatment. Zygomycetes and ascomycetes account for the vast majority of fungal causes of human, animal, and plant disease, large-scale biodiversity loss, agricultural spoilage, and contamination of water-damaged buildings. These studies revealed the conservation of a common cell wall structural component of zygomycetes and ascomycetes to be a diagnostic target applicable to multiple pathogenic fungi and have leveraged that insight for practical use. Monoclonal antibodies reactive with this pan-fungal structure were produced and used to construct immunoassays (including ELISA and lateral flow assay) for detection of a broad range of pathogenic fungi. PMID:29720523

  19. Relationship between esophageal clinical symptoms and manometry findings in patients with esophageal motility disorders: a cross-sectional study.

    PubMed

    FakhreYaseri, Hashem; FakhreYaseri, Ali Mohammad; Baradaran Moghaddam, Ali; Soltani Arabshhi, Seyed Kamran

    2015-01-01

    Manometry is the gold-standard diagnostic test for motility disorders in the esophagus. The development of high-resolution manometry catheters and software displays of manometry recordings in color-coded pressure plots have changed the diagnostic assessment of esophageal disease. The diagnostic value of particular esophageal clinical symptoms among patients suspected of esophageal motor disorders (EMDs) is still unknown. The aim of this study was to explore the sensitivity, specificity, and predictive accuracy of presenting esophageal symptoms between abnormal and normal esophageal manometry findings. We conducted a cross-sectional study of 623 patients aged 11-80 years. Data were collected from clinical examinations as well as patient questionnaires. The sensitivity, specificity, and accuracy were calculated after high-resolution manometry plots were reviewed according to the most recent Chicago Criteria. The clinical symptoms were not sensitive enough to discriminate between EMDs. Nevertheless, dysphagia, noncardiac chest pain, hoarseness, vomiting, and weight loss had high specificity and high accuracy to distinguish EMDs from normal findings. Regurgitation and heartburn did not have good accuracy for the diagnosis of EMDs. Clinical symptoms are not reliable enough to discriminate between EMDs. Clinical symptoms can, however, discriminate between normal findings and EMDs, especially achalasia.

  20. Do patients' disruptive behaviours influence the accuracy of a doctor's diagnosis? A randomised experiment.

    PubMed

    Schmidt, H G; Van Gog, Tamara; Schuit, Stephanie Ce; Van den Berge, Kees; Van Daele, Paul L; Bueving, Herman; Van der Zee, Tim; Van den Broek, Walter W; Van Saase, Jan L; Mamede, Sílvia

    2017-01-01

    Literature suggests that patients who display disruptive behaviours in the consulting room fuel negative emotions in doctors. These emotions, in turn, are said to cause diagnostic errors. Evidence substantiating this claim is however lacking. The purpose of the present experiment was to study the effect of such difficult patients' behaviours on doctors' diagnostic performance. We created six vignettes in which patients were depicted as difficult (displaying distressing behaviours) or neutral. Three clinical cases were deemed to be diagnostically simple and three deemed diagnostically complex. Sixty-three family practice residents were asked to evaluate the vignettes and make the patient's diagnosis quickly and then through deliberate reflection. In addition, amount of time needed to arrive at a diagnosis was measured. Finally, the participants rated the patient's likability. Mean diagnostic accuracy scores (range 0-1) were significantly lower for difficult than for neutral patients (0.54 vs 0.64; p=0.017). Overall diagnostic accuracy was higher for simple than for complex cases. Deliberate reflection upon the case improved initial diagnostic, regardless of case complexity and of patient behaviours (0.60 vs 0.68, p=0.002). Amount of time needed to diagnose the case was similar regardless of the patient's behaviour. Finally, average likability ratings were lower for difficult than for neutral-patient cases. Disruptive behaviours displayed by patients seem to induce doctors to make diagnostic errors. Interestingly, the confrontation with difficult patients does however not cause the doctor to spend less time on such case. Time can therefore not be considered an intermediary between the way the patient is perceived, his or her likability and diagnostic performance. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Endoscopic ultrasound cytologic brushing vs endoscopic ultrasound: fine needle aspiration for cytological diagnosis of cystic pancreatic lesions. A multicenter, randomized open-label trial.

    PubMed

    Lariño-Noia, José; de la Iglesia, Daniel; Iglesias-García, Julio; Macías, Manuel; López Martín, Aurelio; Legaz, María Luisa; Vila, Juan; Reyes, Antonio; Abdulkader, Ihab; Domínguez-Muñoz, J Enrique

    2018-04-24

    the incidence of cystic pancreatic lesions (CPL) in the asymptomatic population is increasing. Achieving a preoperative diagnosis of CPL still remains a challenge. to evaluate the diagnostic accuracy of the cytological diagnosis of CPL from samples obtained by cytology brush versus standard endoscopic ultrasound fine needle aspiration (EUS-FNA). a multicenter, randomized, open-label trial was performed of EUS-cytology brush (EUS-EB) versus EUS-FNA for the cytological diagnosis of CPL. Patients that underwent EUS-FNA with a CPL > 15 mm were included and randomized into two groups: group I, EUS-EB; group II, EUS-FNA. The final diagnosis was based on the histological evaluation of surgical specimens and clinical parameters, imaging and a five year follow-up in non-operated patients. The main outcome was the diagnostic accuracy of both methods. Secondary outcomes were the diagnostic adequacy of specimens and the rate of adverse events. Data were compared using the Chi-squared test. An intention to treat (ITT) and per-protocol (PP) analysis were performed. sixty-five patients were included in the study, 31 in group I and 34 in group II. Three patients initially randomized to group I were changed to group II as it was impossible to obtain a sample using the brush. The mean size of the CPL was 28.2 mm (range 16-60 mm). The diagnostic accuracy of EUS-EB was not superior to EUS-FNA, neither in the ITT nor the PP analysis (44.8% vs 41.1%, p = 0.77 and 38.4% vs 45.9%, p = 0.55). EUS-EB does not improve the diagnostic accuracy of CPL in comparison with EUS-FNA.

  2. Diagnostic digital cytopathology: Are we ready yet?

    PubMed Central

    House, Jarret C.; Henderson-Jackson, Evita B.; Johnson, Joseph O.; Lloyd, Mark C.; Dhillon, Jasreman; Ahmad, Nazeel; Hakam, Ardeshir; Khalbuss, Walid E.; Leon, Marino E.; Chhieng, David; Zhang, Xiaohui; Centeno, Barbara A.; Bui, Marilyn M.

    2013-01-01

    Background: The cytology literature relating to diagnostic accuracy using whole slide imaging is scarce. We studied the diagnostic concordance between glass and digital slides among diagnosticians with different profiles to assess the readiness of adopting digital cytology in routine practice. Materials and Methods: This cohort consisted of 22 de-identified previously screened and diagnosed cases, including non-gynecological and gynecological slides using standard preparations. Glass slides were digitalized using Aperio ScanScope XT (×20 and ×40). Cytopathologists with (3) and without (3) digital experience, cytotechnologists (4) and senior pathology residents (2) diagnosed the digital slides independently first and recorded the results. Glass slides were read and recorded separately 1-3 days later. Accuracy of diagnosis, time to diagnosis and diagnostician's profile were analyzed. Results: Among 22 case pairs and four study groups, correct diagnosis (93% vs. 86%) was established using glass versus digital slides. Both methods more (>95%) accurately diagnosed positive cases than negatives. Cytopathologists with no digital experience were the most accurate in digital diagnosis, even the senior members. Cytotechnologists had the fastest diagnosis time (3 min/digital vs. 1.7 min/glass), but not the best accuracy. Digital time was 1.5 min longer than glass-slide time/per case for cytopathologists and cytotechnologists. Senior pathology residents were slower and less accurate with both methods. Cytopathologists with digital experience ranked 2nd fastest in time, yet last in accuracy for digital slides. Conclusions: There was good overall diagnostic agreement between the digital whole-slide images and glass slides. Although glass slide diagnosis was more accurate and faster, the results of technologists and pathologists with no digital cytology experience suggest that solid diagnostic ability is a strong indicator for readiness of digital adoption. PMID:24392242

  3. Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study

    PubMed Central

    Carnero-Pardo, Cristobal; Gurpegui, Manuel; Sanchez-Cantalejo, Emilio; Frank, Ana; Mola, Santiago; Barquero, M Sagrario; Montoro-Rios, M Teresa

    2006-01-01

    Background Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. Methods A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn), specificity (Sp) and area under the ROC curves (aROC) with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. Results Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84–0.96), Sp = 0.82 (0.77–0.85), and aROC = 0.93 (0.91–0.95). Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. Conclusion This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity. PMID:16606455

  4. Novel rapid molecular diagnosis of fetal chromosomal abnormalities associated with recurrent pregnancy loss.

    PubMed

    Yang, Lan; Tang, Ye; Lu, Mudan; Yang, Yuefen; Xiao, Jianping; Wang, Qiaoxia; Yang, Canfeng; Tao, Hehua; Xiang, Jingying

    2016-12-01

    Labor-intensive karyotyping is used as the reference standard diagnostic test to identify copy number variants (CNVs) in the fetal genome after recurrent pregnancy loss. Our aim was to present and evaluate a novel molecular assay called CNVplex that could potentially be used as an alternative method to conventional karyotyping for diagnosing fetal chromosomal abnormalities associated with recurrent pregnancy loss. Using karyotyping as the reference standard, CNVplex was performed to identify fetal chromosomal abnormalities in the chorionic villus samples from 76 women experiencing at least two pregnancy losses. Its diagnostic accuracy, sensitivity, and specificity were evaluated to detect aneuploidies associated with recurrent pregnancy loss. Turnaround time and costs of CNVplex were also measured. Diagnostic accuracy of CNVplex in aneuploidies that are associated with recurrent pregnancy loss was 1.0 (95% CI 0.94-1.0), sensitivity was 100% (95% CI 0.89-1.0), and specificity was 100% (95% CI 0.875-1.0). Diagnostic accuracy of CNVplex was similar to that of karyotyping. Both karyotyping and CNVplex assay detected 27 autosomal trisomies, three 45,X monosomies, and three polyploidies. CNVplex also detected additional novel structural abnormalities of the fetal genome. Compared with karyotyping, CNVplex significantly (p = 0.001) reduced the waiting time by 13.98 days (95% CI 13.88-14.08) and the cost by US $241 (95% CI 234.53-247.47). CNVplex is a novel effective assay for diagnosing fetal chromosomal abnormalities associated with recurrent pregnancy loss. In the routine clinical work-up of recurrent pregnancy loss, diagnostic accuracy of CNVplex is comparable to that of conventional karyotyping but it requires less waiting time and has lower cost. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  5. Contextual factors and clinical reasoning: differences in diagnostic and therapeutic reasoning in board certified versus resident physicians.

    PubMed

    McBee, Elexis; Ratcliffe, Temple; Picho, Katherine; Schuwirth, Lambert; Artino, Anthony R; Yepes-Rios, Ana Monica; Masel, Jennifer; van der Vleuten, Cees; Durning, Steven J

    2017-11-15

    The impact of context on the complex process of clinical reasoning is not well understood. Using situated cognition as the theoretical framework and videos to provide the same contextual "stimulus" to all participants, we examined the relationship between specific contextual factors on diagnostic and therapeutic reasoning accuracy in board certified internists versus resident physicians. Each participant viewed three videotaped clinical encounters portraying common diagnoses in internal medicine. We explicitly modified the context to assess its impact on performance (patient and physician contextual factors). Patient contextual factors, including English as a second language and emotional volatility, were portrayed in the videos. Physician participant contextual factors were self-rated sleepiness and burnout.. The accuracy of diagnostic and therapeutic reasoning was compared with covariates using Fisher Exact, Mann-Whitney U tests and Spearman Rho's correlations as appropriate. Fifteen board certified internists and 10 resident physicians participated from 2013 to 2014. Accuracy of diagnostic and therapeutic reasoning did not differ between groups despite residents reporting significantly higher rates of sleepiness (mean rank 20.45 vs 8.03, U = 0.5, p < .001) and burnout (mean rank 20.50 vs 8.00, U = 0.0, p < .001). Accuracy of diagnosis and treatment were uncorrelated (r = 0.17, p = .65). In both groups, the proportion scoring correct responses for treatment was higher than the proportion scoring correct responses for diagnosis. This study underscores that specific contextual factors appear to impact clinical reasoning performance. Further, the processes of diagnostic and therapeutic reasoning, although related, may not be interchangeable. This raises important questions about the impact that contextual factors have on clinical reasoning and provides insight into how clinical reasoning processes in more authentic settings may be explained by situated cognition theory.

  6. Accuracy of i-Scan for Optical Diagnosis of Colonic Polyps: A Meta-Analysis

    PubMed Central

    Guo, Chuan-Guo; Ji, Rui; Li, Yan-Qing

    2015-01-01

    Background i-Scan is a novel virtual chromoendoscopy system designed to enhance surface and vascular patterns to improve optical diagnostic performance. Numerous prospective studies have been done to evaluate the accuracy of i-Scan in differentiating colonic neoplasms from non-neoplasms. i-Scan could be an effective endoscopic technique for optical diagnosis of colonic polyps. Objective Our aim of this study was to perform a meta-analysis of published data to establish the diagnostic accuracy of i-Scan for optical diagnosis of colonic polyps. Methods We searched PubMed, Medline, Elsevier ScienceDirect and Cochrane Library databases. We used a bivariate meta-analysis following a random effects model to summarize the data and plotted hierarchical summary receiver-operating characteristic (HSROC) curves. The area under the HSROC curve (AUC) serves as an indicator of the diagnostic accuracy. Results The meta-analysis included a total of 925 patients and 2312 polyps. For the overall studies, the area under the HSROC curve was 0.96. The summary sensitivity was 90.4% (95%CI 85%-94.1%) and specificity was 90.9% (95%CI 84.3%-94.9%). In 11 studies predicting polyps histology in real-time, the summary sensitivity and specificity was 91.5% (95%CI 85.7%-95.1%) and 92.1% (95%CI 84.5%-96.1%), respectively, with the AUC of 0.97. For three different diagnostic criteria (Kudo, NICE, others), the sensitivity was 86.3%, 93.0%, 85.0%, respectively and specificity was 84.8%, 94.4%, 91.8%, respectively. Conclusions Endoscopic diagnosis with i-Scan has accurate optical diagnostic performance to differentiate neoplastic from non-neoplastic polyps with an area under the HSROC curve exceeding 0.90. Both the sensitivity and specificity for diagnosing colonic polyps are over 90%. PMID:25978459

  7. The diagnostic accuracy of multi-frequency bioelectrical impedance analysis in diagnosing dehydration after stroke

    PubMed Central

    Kafri, Mohannad W.; Myint, Phyo Kyaw; Doherty, Danielle; Wilson, Alexander Hugh; Potter, John F.; Hooper, Lee

    2013-01-01

    Background Non-invasive methods for detecting water-loss dehydration following acute stroke would be clinically useful. We evaluated the diagnostic accuracy of multi-frequency bioelectrical impedance analysis (MF-BIA) against reference standards serum osmolality and osmolarity. Material/Methods Patients admitted to an acute stroke unit were recruited. Blood samples for electrolytes and osmolality were taken within 20 minutes of MF-BIA. Total body water (TBW%), intracellular (ICW%) and extracellular water (ECW%), as percentages of total body weight, were calculated by MF-BIA equipment and from impedance measures using published equations for older people. These were compared to hydration status (based on serum osmolality and calculated osmolarity). The most promising Receiver Operating Characteristics curves were plotted. Results 27 stroke patients were recruited (mean age 71.3, SD10.7). Only a TBW% cut-off at 46% was consistent with current dehydration (serum osmolality >300 mOsm/kg) and TBW% at 47% impending dehydration (calculated osmolarity ≥295–300 mOsm/L) with sensitivity and specificity both >60%. Even here diagnostic accuracy of MF-BIA was poor, a third of those with dehydration were wrongly classified as hydrated and a third classified as dehydrated were well hydrated. Secondary analyses assessing diagnostic accuracy of TBW% for men and women separately, and using TBW as a percentage of lean body mass showed some promise, but did not provide diagnostically accurate measures across the population. Conclusions MF-BIA appears ineffective at diagnosing water-loss dehydration after stroke and cannot be recommended as a test for dehydration, but separating assessment by sex, and using TBW as a percentage of lean body weight may warrant further investigation. PMID:23839255

  8. Five common tumor biomarkers and CEA for diagnosing early gastric cancer: A protocol for a network meta-analysis of diagnostic test accuracy.

    PubMed

    Shen, Minghui; Wang, Hui; Wei, Kongyuan; Zhang, Jianling; You, Chongge

    2018-05-01

    Although surgical resection is the recommended treatment for the patients with gastric cancer, lots of patients show advanced or metastatic gastric cancer at the time of diagnosis. Detection of gastric cancer at early stages is a huge challenge because of lack of appropriate detection tests. Unfortunately, existing clinical guidelines focusing on early diagnosis of gastric cancer do not provide consistent and prudent evidence. Serum carcinoembryonic antigen was considered as a complementary test, although it is not good enough to diagnose early gastric cancer. There are no other tumor markers recommended for diagnosing early gastric cancer. This study aims to evaluate and compare the diagnostic accuracy of 5 common tumor biomarkers (CA19-9, CA125, PG, IncRNA, and DNA methylation) and CEA and their combinations for diagnosing gastric cancer through network meta-analysis method, and to rank these tests using a superiority index. PubMed, EMBASE.com, and the Cochrane Central Register of Controlled Trials (CENTRAL) will be searched from their inception to March 2018. We will include diagnostic tests which assessed the accuracy of the above-mentioned tumor biomarkers and CEA for diagnosing gastric cancer. The risk of bias for each study will be independently assessed as low, moderate, or high using criteria adapted from Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Network meta-analysis will be performed using STATA 12.0 and R 3.4.1 software. The competing diagnostic tests will be ranked by a superiority index. This study is ongoing and will be submitted to a peer-reviewed journal for publication. This study will provide systematically suggestions to select different tumor biomarkers for detecting the early gastric cancer.

  9. Walking on thin ice! Identifying methamphetamine "drug mules" on digital plain radiography.

    PubMed

    Abdul Rashid, S N; Mohamad Saini, S B; Abdul Hamid, S; Muhammad, S J; Mahmud, R; Thali, M J; Flach, P M

    2014-04-01

    The purpose of this study was to retrospectively evaluate the sensitivity, specificity and accuracy of identifying methamphetamine (MA) internal payloads in "drug mules" by plain abdominal digital radiography (DR). The study consisted of 35 individuals suspected of internal MA drug containers. A total of 59 supine digital radiographs were collected. An overall calculation regarding the diagnostic accuracy for all "drug mules" and a specific evaluation concerning the radiological appearance of drug packs as well as the rate of clearance and complications in correlation with the reader's experience were performed. The gold standard was the presence of secured drug packs in the faeces. There were 16 true-positive "drug mules" identified. DR of all drug carriers for Group 1 (forensic imaging experienced readers, n = 2) exhibited a sensitivity of 100%, a mean specificity of 76.3%, positive predictive value (PPV) of 78.5%, negative predictive value (NPV) of 100% and a mean accuracy 87.2%. Group 2 (inexperienced readers, n = 3) showed a lower sensitivity (93.7%), a mean specificity of 86%, a PPV of 86.5%, an NPV of 94.1% and a mean accuracy of 89.5%. The interrater agreement within Group 1 was 0.72 and within Group 2 averaged to 0.79, indicating a fair to very good agreement. DR is a valuable screening tool in cases of MA body packers with huge internal payloads being associated with a high diagnostic insecurity. Diagnostic insecurity on plain films may be overcome by low-dose CT as a cross-sectional imaging modality and addressed by improved radiological education in reporting drug carriers on imaging. Diagnostic signs (double-condom and halo signs) on digital plain radiography are specific in MA "drug mules", although DR is associated with high diagnostic insecurity and underreports the total internal payload.

  10. Accurate ECG diagnosis of atrial tachyarrhythmias using quantitative analysis: a prospective diagnostic and cost-effectiveness study.

    PubMed

    Krummen, David E; Patel, Mitul; Nguyen, Hong; Ho, Gordon; Kazi, Dhruv S; Clopton, Paul; Holland, Marian C; Greenberg, Scott L; Feld, Gregory K; Faddis, Mitchell N; Narayan, Sanjiv M

    2010-11-01

    Quantitative ECG Analysis. Optimal atrial tachyarrhythmia management is facilitated by accurate electrocardiogram interpretation, yet typical atrial flutter (AFl) may present without sawtooth F-waves or RR regularity, and atrial fibrillation (AF) may be difficult to separate from atypical AFl or rapid focal atrial tachycardia (AT). We analyzed whether improved diagnostic accuracy using a validated analysis tool significantly impacts costs and patient care. We performed a prospective, blinded, multicenter study using a novel quantitative computerized algorithm to identify atrial tachyarrhythmia mechanism from the surface ECG in patients referred for electrophysiology study (EPS). In 122 consecutive patients (age 60 ± 12 years) referred for EPS, 91 sustained atrial tachyarrhythmias were studied. ECGs were also interpreted by 9 physicians from 3 specialties for comparison and to allow healthcare system modeling. Diagnostic accuracy was compared to the diagnosis at EPS. A Markov model was used to estimate the impact of improved arrhythmia diagnosis. We found 13% of typical AFl ECGs had neither sawtooth flutter waves nor RR regularity, and were misdiagnosed by the majority of clinicians (0/6 correctly diagnosed by consensus visual interpretation) but correctly by quantitative analysis in 83% (5/6, P = 0.03). AF diagnosis was also improved through use of the algorithm (92%) versus visual interpretation (primary care: 76%, P < 0.01). Economically, we found that these improvements in diagnostic accuracy resulted in an average cost-savings of $1,303 and 0.007 quality-adjusted-life-years per patient. Typical AFl and AF are frequently misdiagnosed using visual criteria. Quantitative analysis improves diagnostic accuracy and results in improved healthcare costs and patient outcomes. © 2010 Wiley Periodicals, Inc.

  11. Reliability and diagnostic accuracy of history and physical examination for diagnosing glenoid labral tears.

    PubMed

    Walsworth, Matthew K; Doukas, William C; Murphy, Kevin P; Mielcarek, Billie J; Michener, Lori A

    2008-01-01

    Glenoid labral tears provide a diagnostic challenge. Combinations of items in the patient history and physical examination will provide stronger diagnostic accuracy to suggest the presence or absence of glenoid labral tear than will individual items. Cohort study (diagnosis); Level of evidence, 1. History and examination findings in patients with shoulder pain (N = 55) were compared with arthroscopic findings to determine diagnostic accuracy and intertester reliability. The intertester reliability of the crank, anterior slide, and active compression tests was 0.20 to 0.24. A combined history of popping or catching and positive crank or anterior slide results yielded specificities of 0.91 and 1.00 and positive likelihood ratios of 3.0 and infinity, respectively. A positive anterior slide result combined with either a positive active compression or crank result yielded specificities of 0.91 and positive likelihood ratio of 2.75 and 3.75, respectively. Requiring only a single positive finding in the combination of popping or catching and the anterior slide or crank yielded sensitivities of 0.82 and 0.89 and negative likelihood ratios of 0.31 and 0.33, respectively. The diagnostic accuracy of individual tests in previous studies is quite variable, which may be explained in part by the modest reliability of these tests. The combination of popping or catching with a positive crank or anterior slide result or a positive anterior slide result with a positive active compression or crank test result suggests the presence of a labral tear. The combined absence of popping or catching and a negative anterior slide or crank result suggests the absence of a labral tear.

  12. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography.

    PubMed

    Jöres, A P W; Heverhagen, J T; Bonél, H; Exadaktylos, A; Klink, T

    2016-02-01

    The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT.  The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %. The diagnostic reference standard MSCT is the preferred and reliable imaging modality. LS may be valuable for quick detection of extremity fractures. © Georg Thieme Verlag KG Stuttgart · New York.

  13. The diagnostic value of a new fecal marker, matrix metalloprotease-9, in different types of inflammatory bowel diseases.

    PubMed

    Farkas, Klaudia; Saródi, Zoltán; Bálint, Anita; Földesi, Imre; Tiszlavicz, László; Szűcs, Mónika; Nyári, Tibor; Tajti, János; Nagy, Ferenc; Szepes, Zoltán; Bor, Renáta; Annaházi, Anita; Róka, Richárd; Molnár, Tamás

    2015-03-01

    Only limited data are available regarding the diagnostic accuracy of fecal matrix metalloprotease-9 [MMP-9] for inflammatory bowel disease [IBD]. The aims of our study were to assess the diagnostic accuracy of fecal MMP-9 in patients with active Crohn's disease [CD], ulcerative colitis [UC], and pouchitis, and to compare the diagnostic accuracy of fecal MMP-9 and fecal calprotectin [CP] in IBD. Stool and blood samples were collected in 50 CD, 54 UC, and 34 ileal pouch-anal anastomosis patients before control endoscopies were performed. Biopsies were taken for histologic purposes. The activities of CD, UC, and pouchitis were defined with the use of clinical, endoscopic, and histologic activity scores. Fecal CP and MMP-9 levels were quantified by enzyme-linked immunosorbent assay. Active CD, UC, and pouchitis were detected in 38%, 54%, and 29% of the patients, respectively. A significant correlation was revealed between fecal CP and the clinical activities of CD and UC, and between fecal CP and the endoscopic activity of UC and pouchitis. Fecal MMP-9 did not correlate with any of the activity indices of CD; however, strong associations were shown between fecal MMP-9 and clinical, endoscopic, and histologic activities of both UC and pouchitis. This is the first study assessing the diagnostic accuracy of MMP-9 in different types of IBD. Our results showed that fecal MMP-9 has high sensitivity in the detection of endoscopically active UC and pouchitis. These non-invasive methods help assess intestinal inflammation. Copyright © 2015 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  14. SLOWLY REPEATED EVOKED PAIN (SREP) AS A MARKER OF CENTRAL SENSITIZATION IN FIBROMYALGIA: DIAGNOSTIC ACCURACY AND RELIABILITY IN COMPARISON WITH TEMPORAL SUMMATION OF PAIN.

    PubMed

    de la Coba, Pablo; Bruehl, Stephen; Gálvez-Sánchez, Carmen María; Reyes Del Paso, Gustavo A

    2018-05-01

    This study examined the diagnostic accuracy and test-retest reliability of a novel dynamic evoked pain protocol (slowly repeated evoked pain; SREP) compared to temporal summation of pain (TSP), a standard index of central sensitization. Thirty-five fibromyalgia (FM) and 30 rheumatoid arthritis (RA) patients completed, in pseudorandomized order, a standard mechanical TSP protocol (10 stimuli of 1s duration at the thenar eminence using a 300g monofilament with 1s interstimulus interval) and the SREP protocol (9 suprathreshold pressure stimuli of 5s duration applied to the fingernail with a 30s interstimulus interval). In order to evaluate reliability for both protocols, they were repeated in a second session 4-7 days later. Evidence for significant pain sensitization over trials (increasing pain intensity ratings) was observed for SREP in FM (p<.001) but not in RA (p=.35), whereas significant sensitization was observed in both diagnostic groups for the TSP protocol (p's<.008). Compared to TSP, SREP demonstrated higher overall diagnostic accuracy (87.7% vs. 64.6%), greater sensitivity (0.89 vs. 0.57), and greater specificity (0.87 vs. 0.73) in discriminating between FM and RA patients. Test-retest reliability of SREP sensitization was good in FM (ICCs: 0.80), and moderate in RA (ICC: 0.68). SREP seems to be a dynamic evoked pain index tapping into pain sensitization that allows for greater diagnostic accuracy in identifying FM patients compared to a standard TSP protocol. Further research is needed to study mechanisms underlying SREP and the potential utility of adding SREP to standard pain evaluation protocols.

  15. Independent value of image fusion in unenhanced breast MRI using diffusion-weighted and morphological T2-weighted images for lesion characterization in patients with recently detected BI-RADS 4/5 x-ray mammography findings.

    PubMed

    Bickelhaupt, Sebastian; Tesdorff, Jana; Laun, Frederik Bernd; Kuder, Tristan Anselm; Lederer, Wolfgang; Teiner, Susanne; Maier-Hein, Klaus; Daniel, Heidi; Stieber, Anne; Delorme, Stefan; Schlemmer, Heinz-Peter

    2017-02-01

    The aim of this study was to evaluate the accuracy and applicability of solitarily reading fused image series of T2-weighted and high-b-value diffusion-weighted sequences for lesion characterization as compared to sequential or combined image analysis of these unenhanced sequences and to contrast- enhanced breast MRI. This IRB-approved study included 50 female participants with suspicious breast lesions detected in screening X-ray mammograms, all of which provided written informed consent. Prior to biopsy, all women underwent MRI including diffusion-weighted imaging (DWIBS, b = 1500s/mm 2 ). Images were analyzed as follows: prospective image fusion of DWIBS and T2-weighted images (FU), side-by-side analysis of DWIBS and T2-weighted series (CO), combination of the first two methods (CO+FU), and full contrast-enhanced diagnostic protocol (FDP). Diagnostic indices, confidence, and image quality of the protocols were compared by two blinded readers. Reading the CO+FU (accuracy 0.92; NPV 96.1 %; PPV 87.6 %) and the CO series (0.90; 96.1 %; 83.7 %) provided a diagnostic performance similar to the FDP (0.95; 96.1 %; 91.3 %; p > 0.05). FU reading alone significantly reduced the diagnostic accuracy (0.82; 93.3 %; 73.4 %; p = 0.023). MR evaluation of suspicious BI-RADS 4 and 5 lesions detected on mammography by using a non-contrast-enhanced T2-weighted and DWIBS sequence protocol is most accurate if MR images were read using the CO+FU protocol. • Unenhanced breast MRI with additional DWIBS/T2w-image fusion allows reliable lesion characterization. • Abbreviated reading of fused DWIBS/T2w-images alone decreases diagnostic confidence and accuracy. • Reading fused DWIBS/T2w-images as the sole diagnostic method should be avoided.

  16. Impact of history of heart failure on diagnostic and prognostic value of BNP: results from the B-type Natriuretic Peptide for Acute Shortness of Breath Evaluation (BASEL) study.

    PubMed

    Boldanova, Tujana; Noveanu, Markus; Breidthardt, Tobias; Potocki, Mihael; Reichlin, Tobias; Taegtmeyer, Anne; Christ, Michael; Laule, Kirsten; Stelzig, Claudia; Mueller, Christian

    2010-07-23

    This study aimed to examine the influence of history of heart failure (HF) on circulating levels, diagnostic accuracy and prognostic value of B-type natriuretic peptide (BNP) in patients presenting with all cause dyspnea at the emergency department. BNP has been shown to be very helpful in diagnosis and prognosis of HF. Due to chronically elevated cardiac filling pressures, patients with a history of HF might have higher BNP levels and therefore diagnostic and prognostic properties of BNP may be affected. We analyzed circulating levels, diagnostic accuracy and prognostic value of BNP in 388 patients without a previous history of HF and compared these to data to 64 patients with a history of HF included in the B-type Natriuretic Peptide for Acute Shortness of Breath Evaluation (BASEL) Study. Baseline BNP levels were higher in patients with a history of HF (median 814 pg/ml [353-1300 pg/ml] vs. 216 pg/ml [45-801 pg/ml], p<0.001). Diagnostic accuracy of BNP to identify HF was comparable in patients with (AUC=0.804; 95% CI 0.628-0.980) and in patients without history of HF (AUC=0.883; 95% CI 0.848-0.919, p=0.389). Prognostic ability of BNP to predict one-year mortality was lower in overall patients with history of HF (AUC=0.458; 95%CI 0.294-0.622) compared to patients without history of HF (AUC=0.710; 95% CI 0.653-0.768, p<0.05). In patients with history of HF, BNP levels retain diagnostic accuracy. Ability to predict one-year mortality was decreased in unselected patients, but not in patients with acute HF-induced dyspnea. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Risk-adjusted capitation based on the Diagnostic Cost Group Model: an empirical evaluation with health survey information.

    PubMed Central

    Lamers, L M

    1999-01-01

    OBJECTIVE: To evaluate the predictive accuracy of the Diagnostic Cost Group (DCG) model using health survey information. DATA SOURCES/STUDY SETTING: Longitudinal data collected for a sample of members of a Dutch sickness fund. In the Netherlands the sickness funds provide compulsory health insurance coverage for the 60 percent of the population in the lowest income brackets. STUDY DESIGN: A demographic model and DCG capitation models are estimated by means of ordinary least squares, with an individual's annual healthcare expenditures in 1994 as the dependent variable. For subgroups based on health survey information, costs predicted by the models are compared with actual costs. Using stepwise regression procedures a subset of relevant survey variables that could improve the predictive accuracy of the three-year DCG model was identified. Capitation models were extended with these variables. DATA COLLECTION/EXTRACTION METHODS: For the empirical analysis, panel data of sickness fund members were used that contained demographic information, annual healthcare expenditures, and diagnostic information from hospitalizations for each member. In 1993, a mailed health survey was conducted among a random sample of 15,000 persons in the panel data set, with a 70 percent response rate. PRINCIPAL FINDINGS: The predictive accuracy of the demographic model improves when it is extended with diagnostic information from prior hospitalizations (DCGs). A subset of survey variables further improves the predictive accuracy of the DCG capitation models. The predictable profits and losses based on survey information for the DCG models are smaller than for the demographic model. Most persons with predictable losses based on health survey information were not hospitalized in the preceding year. CONCLUSIONS: The use of diagnostic information from prior hospitalizations is a promising option for improving the demographic capitation payment formula. This study suggests that diagnostic information from outpatient utilization is complementary to DCGs in predicting future costs. PMID:10029506

  18. Memory color of natural familiar objects: effects of surface texture and 3-D shape.

    PubMed

    Vurro, Milena; Ling, Yazhu; Hurlbert, Anya C

    2013-06-28

    Natural objects typically possess characteristic contours, chromatic surface textures, and three-dimensional shapes. These diagnostic features aid object recognition, as does memory color, the color most associated in memory with a particular object. Here we aim to determine whether polychromatic surface texture, 3-D shape, and contour diagnosticity improve memory color for familiar objects, separately and in combination. We use solid three-dimensional familiar objects rendered with their natural texture, which participants adjust in real time to match their memory color for the object. We analyze mean, accuracy, and precision of the memory color settings relative to the natural color of the objects under the same conditions. We find that in all conditions, memory colors deviate slightly but significantly in the same direction from the natural color. Surface polychromaticity, shape diagnosticity, and three dimensionality each improve memory color accuracy, relative to uniformly colored, generic, or two-dimensional shapes, respectively. Shape diagnosticity improves the precision of memory color also, and there is a trend for polychromaticity to do so as well. Differently from other studies, we find that the object contour alone also improves memory color. Thus, enhancing the naturalness of the stimulus, in terms of either surface or shape properties, enhances the accuracy and precision of memory color. The results support the hypothesis that memory color representations are polychromatic and are synergistically linked with diagnostic shape representations.

  19. FDG-PET improves accuracy in distinguishing frontotemporal dementia and Alzheimer's disease.

    PubMed

    Foster, Norman L; Heidebrink, Judith L; Clark, Christopher M; Jagust, William J; Arnold, Steven E; Barbas, Nancy R; DeCarli, Charles S; Turner, R Scott; Koeppe, Robert A; Higdon, Roger; Minoshima, Satoshi

    2007-10-01

    Distinguishing Alzheimer's disease (AD) and frontotemporal dementia (FTD) currently relies on a clinical history and examination, but positron emission tomography with [(18)F] fluorodeoxyglucose (FDG-PET) shows different patterns of hypometabolism in these disorders that might aid differential diagnosis. Six dementia experts with variable FDG-PET experience made independent, forced choice, diagnostic decisions in 45 patients with pathologically confirmed AD (n = 31) or FTD (n = 14) using five separate methods: (1) review of clinical summaries, (2) a diagnostic checklist alone, (3) summary and checklist, (4) transaxial FDG-PET scans and (5) FDG-PET stereotactic surface projection (SSP) metabolic and statistical maps. In addition, we evaluated the effect of the sequential review of a clinical summary followed by SSP. Visual interpretation of SSP images was superior to clinical assessment and had the best inter-rater reliability (mean kappa = 0.78) and diagnostic accuracy (89.6%). It also had the highest specificity (97.6%) and sensitivity (86%), and positive likelihood ratio for FTD (36.5). The addition of FDG-PET to clinical summaries increased diagnostic accuracy and confidence for both AD and FTD. It was particularly helpful when raters were uncertain in their clinical diagnosis. Visual interpretation of FDG-PET after brief training is more reliable and accurate in distinguishing FTD from AD than clinical methods alone. FDG-PET adds important information that appropriately increases diagnostic confidence, even among experienced dementia specialists.

  20. A fast Monte Carlo EM algorithm for estimation in latent class model analysis with an application to assess diagnostic accuracy for cervical neoplasia in women with AGC

    PubMed Central

    Kang, Le; Carter, Randy; Darcy, Kathleen; Kauderer, James; Liao, Shu-Yuan

    2013-01-01

    In this article we use a latent class model (LCM) with prevalence modeled as a function of covariates to assess diagnostic test accuracy in situations where the true disease status is not observed, but observations on three or more conditionally independent diagnostic tests are available. A fast Monte Carlo EM (MCEM) algorithm with binary (disease) diagnostic data is implemented to estimate parameters of interest; namely, sensitivity, specificity, and prevalence of the disease as a function of covariates. To obtain standard errors for confidence interval construction of estimated parameters, the missing information principle is applied to adjust information matrix estimates. We compare the adjusted information matrix based standard error estimates with the bootstrap standard error estimates both obtained using the fast MCEM algorithm through an extensive Monte Carlo study. Simulation demonstrates that the adjusted information matrix approach estimates the standard error similarly with the bootstrap methods under certain scenarios. The bootstrap percentile intervals have satisfactory coverage probabilities. We then apply the LCM analysis to a real data set of 122 subjects from a Gynecologic Oncology Group (GOG) study of significant cervical lesion (S-CL) diagnosis in women with atypical glandular cells of undetermined significance (AGC) to compare the diagnostic accuracy of a histology-based evaluation, a CA-IX biomarker-based test and a human papillomavirus (HPV) DNA test. PMID:24163493

  1. Diagnostic accuracy of a clinical diagnosis of idiopathic pulmonary fibrosis: an international case–cohort study

    PubMed Central

    Maher, Toby M.; Kolb, Martin; Poletti, Venerino; Nusser, Richard; Richeldi, Luca; Vancheri, Carlo; Wilsher, Margaret L.; Antoniou, Katerina M.; Behr, Jüergen; Bendstrup, Elisabeth; Brown, Kevin; Calandriello, Lucio; Corte, Tamera J.; Crestani, Bruno; Flaherty, Kevin; Glaspole, Ian; Grutters, Jan; Inoue, Yoshikazu; Kokosi, Maria; Kondoh, Yasuhiro; Kouranos, Vasileios; Kreuter, Michael; Johannson, Kerri; Judge, Eoin; Ley, Brett; Margaritopoulos, George; Martinez, Fernando J.; Molina-Molina, Maria; Morais, António; Nunes, Hilario; Raghu, Ganesh; Ryerson, Christopher J.; Selman, Moises; Spagnolo, Paolo; Taniguchi, Hiroyuki; Tomassetti, Sara; Valeyre, Dominique; Wijsenbeek, Marlies; Wuyts, Wim; Hansell, David; Wells, Athol

    2017-01-01

    We conducted an international study of idiopathic pulmonary fibrosis (IPF) diagnosis among a large group of physicians and compared their diagnostic performance to a panel of IPF experts. A total of 1141 respiratory physicians and 34 IPF experts participated. Participants evaluated 60 cases of interstitial lung disease (ILD) without interdisciplinary consultation. Diagnostic agreement was measured using the weighted kappa coefficient (κw). Prognostic discrimination between IPF and other ILDs was used to validate diagnostic accuracy for first-choice diagnoses of IPF and were compared using the C-index. A total of 404 physicians completed the study. Agreement for IPF diagnosis was higher among expert physicians (κw=0.65, IQR 0.53–0.72, p<0.0001) than academic physicians (κw=0.56, IQR 0.45–0.65, p<0.0001) or physicians with access to multidisciplinary team (MDT) meetings (κw=0.54, IQR 0.45–0.64, p<0.0001). The prognostic accuracy of academic physicians with >20 years of experience (C-index=0.72, IQR 0.0–0.73, p=0.229) and non-university hospital physicians with more than 20 years of experience, attending weekly MDT meetings (C-index=0.72, IQR 0.70–0.72, p=0.052), did not differ significantly (p=0.229 and p=0.052 respectively) from the expert panel (C-index=0.74 IQR 0.72–0.75). Experienced respiratory physicians at university-based institutions diagnose IPF with similar prognostic accuracy to IPF experts. Regular MDT meeting attendance improves the prognostic accuracy of experienced non-university practitioners to levels achieved by IPF experts. PMID:28860269

  2. A simple and robust classification tree for differentiation between benign and malignant lesions in MR-mammography.

    PubMed

    Baltzer, Pascal A T; Dietzel, Matthias; Kaiser, Werner A

    2013-08-01

    In the face of multiple available diagnostic criteria in MR-mammography (MRM), a practical algorithm for lesion classification is needed. Such an algorithm should be as simple as possible and include only important independent lesion features to differentiate benign from malignant lesions. This investigation aimed to develop a simple classification tree for differential diagnosis in MRM. A total of 1,084 lesions in standardised MRM with subsequent histological verification (648 malignant, 436 benign) were investigated. Seventeen lesion criteria were assessed by 2 readers in consensus. Classification analysis was performed using the chi-squared automatic interaction detection (CHAID) method. Results include the probability for malignancy for every descriptor combination in the classification tree. A classification tree incorporating 5 lesion descriptors with a depth of 3 ramifications (1, root sign; 2, delayed enhancement pattern; 3, border, internal enhancement and oedema) was calculated. Of all 1,084 lesions, 262 (40.4 %) and 106 (24.3 %) could be classified as malignant and benign with an accuracy above 95 %, respectively. Overall diagnostic accuracy was 88.4 %. The classification algorithm reduced the number of categorical descriptors from 17 to 5 (29.4 %), resulting in a high classification accuracy. More than one third of all lesions could be classified with accuracy above 95 %. • A practical algorithm has been developed to classify lesions found in MR-mammography. • A simple decision tree consisting of five criteria reaches high accuracy of 88.4 %. • Unique to this approach, each classification is associated with a diagnostic certainty. • Diagnostic certainty of greater than 95 % is achieved in 34 % of all cases.

  3. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  4. Value of lower respiratory tract surveillance cultures to predict bacterial pathogens in ventilator-associated pneumonia: systematic review and diagnostic test accuracy meta-analysis.

    PubMed

    Brusselaers, Nele; Labeau, Sonia; Vogelaers, Dirk; Blot, Stijn

    2013-03-01

    In ventilator-associated pneumonia (VAP), early appropriate antimicrobial therapy may be hampered by involvement of multidrug-resistant (MDR) pathogens. A systematic review and diagnostic test accuracy meta-analysis were performed to analyse whether lower respiratory tract surveillance cultures accurately predict the causative pathogens of subsequent VAP in adult patients. Selection and assessment of eligibility were performed by three investigators by mutual consideration. Of the 525 studies retrieved, 14 were eligible for inclusion (all in English; published since 1994), accounting for 791 VAP episodes. The following data were collected: study and population characteristics; in- and exclusion criteria; diagnostic criteria for VAP; microbiological workup of surveillance and diagnostic VAP cultures. Sub-analyses were conducted for VAP caused by Staphylococcus aureus, Pseudomonas spp., and Acinetobacter spp., MDR microorganisms, frequency of sampling, and consideration of all versus the most recent surveillance cultures. The meta-analysis showed a high accuracy of surveillance cultures, with pooled sensitivities up to 0.75 and specificities up to 0.92 in culture-positive VAP. The area under the curve (AUC) of the hierarchical summary receiver-operating characteristic curve demonstrates moderate accuracy (AUC: 0.90) in predicting multidrug resistance. A sampling frequency of >2/week (sensitivity 0.79; specificity 0.96) and consideration of only the most recent surveillance culture (sensitivity 0.78; specificity 0.96) are associated with a higher accuracy of prediction. This study provides evidence for the benefit of surveillance cultures in predicting MDR bacterial pathogens in VAP. However, clinical and statistical heterogeneity, limited samples sizes, and bias remain important limitations of this meta-analysis.

  5. Contextual information influences diagnosis accuracy and decision making in simulated emergency medicine emergencies.

    PubMed

    McRobert, Allistair Paul; Causer, Joe; Vassiliadis, John; Watterson, Leonie; Kwan, James; Williams, Mark A

    2013-06-01

    It is well documented that adaptations in cognitive processes with increasing skill levels support decision making in multiple domains. We examined skill-based differences in cognitive processes in emergency medicine physicians, and whether performance was significantly influenced by the removal of contextual information related to a patient's medical history. Skilled (n=9) and less skilled (n=9) emergency medicine physicians responded to high-fidelity simulated scenarios under high- and low-context information conditions. Skilled physicians demonstrated higher diagnostic accuracy irrespective of condition, and were less affected by the removal of context-specific information compared with less skilled physicians. The skilled physicians generated more options, and selected better quality options during diagnostic reasoning compared with less skilled counterparts. These cognitive processes were active irrespective of the level of context-specific information presented, although high-context information enhanced understanding of the patients' symptoms resulting in higher diagnostic accuracy. Our findings have implications for scenario design and the manipulation of contextual information during simulation training.

  6. Perendoscopic gastric pH determination. Simple method for increasing accuracy in diagnosing chronic atrophic gastritis.

    PubMed

    Farinati, F; Cardin, F; Di Mario, F; Sava, G A; Piccoli, A; Costa, F; Penon, G; Naccarato, R

    1987-08-01

    The endoscopic diagnosis of chronic atrophic gastritis is often underestimated, and most of the procedures adopted to increase diagnostic accuracy are time consuming and complex. In this study, we evaluated the usefulness of the determination of gastric juice pH by means of litmus paper. Values obtained by this method correlate well with gastric acid secretory capacity as measured by gastric acid analysis (r = -0.64, p less than 0.001) and are not affected by the presence of bile. Gastric juice pH determination increases sensitivity and other diagnostic parameters such as performance index (Youden J test), positive predictive value, and post-test probability difference by 50%. Furthermore, the negative predictive value is very high, the probability of missing a patient with chronic atrophic gastritis with this simple method being 2% for fundic and 15% for antral atrophic change. We conclude that gastric juice pH determination, which substantially increases diagnostic accuracy and is very simple to perform, should be routinely adopted.

  7. A vine copula mixed effect model for trivariate meta-analysis of diagnostic test accuracy studies accounting for disease prevalence.

    PubMed

    Nikoloulopoulos, Aristidis K

    2017-10-01

    A bivariate copula mixed model has been recently proposed to synthesize diagnostic test accuracy studies and it has been shown that it is superior to the standard generalized linear mixed model in this context. Here, we call trivariate vine copulas to extend the bivariate meta-analysis of diagnostic test accuracy studies by accounting for disease prevalence. Our vine copula mixed model includes the trivariate generalized linear mixed model as a special case and can also operate on the original scale of sensitivity, specificity, and disease prevalence. Our general methodology is illustrated by re-analyzing the data of two published meta-analyses. Our study suggests that there can be an improvement on trivariate generalized linear mixed model in fit to data and makes the argument for moving to vine copula random effects models especially because of their richness, including reflection asymmetric tail dependence, and computational feasibility despite their three dimensionality.

  8. Diagnostic accuracy of three scoring methods for the Davidson Trauma Scale among U.S. military veterans.

    PubMed

    McDonald, Scott D; Thompson, NiVonne L; Stratton, Kelcey J; Calhoun, Patrick S

    2014-03-01

    Self-report questionnaires are frequently used to identify PTSD among U.S. military personnel and Veterans. Two common scoring methods used to classify PTSD include: (1) a cut score threshold and (2) endorsement of PTSD symptoms meeting DSM-IV-TR symptom cluster criteria (SCM). A third method requiring a cut score in addition to SCM has been proposed, but has received little study. The current study examined the diagnostic accuracy of three scoring methods for the Davidson Trauma Scale (DTS) among 804 Afghanistan and Iraq war-era military Service Members and Veterans. Data were weighted to approximate the prevalence of PTSD and other Axis I disorders in VA primary care. As expected, adding a cut score criterion to SCM improved specificity and positive predictive power. However, a cut score of 68-72 provided optimal diagnostic accuracy. The utility of the DTS, the role of baseline prevalence, and recommendations for future research are discussed. Published by Elsevier Ltd.

  9. Descent advisor preliminary field test

    NASA Technical Reports Server (NTRS)

    Green, Steven M.; Vivona, Robert A.; Sanford, Beverly

    1995-01-01

    A field test of the Descent Advisor (DA) automation tool was conducted at the Denver Air Route Traffic Control Center in September 1994. DA is being developed to assist Center controllers in the efficient management and control of arrival traffic. DA generates advisories, based on trajectory predictions, to achieve accurate meter-fix arrival times in a fuel efficient manner while assisting the controller with the prediction and resolution of potential conflicts. The test objectives were to evaluate the accuracy of DA trajectory predictions for conventional- and flight-management-system-equipped jet transports, to identify significant sources of trajectory prediction error, and to investigate procedural and training issues (both air and ground) associated with DA operations. Various commercial aircraft (97 flights total) and a Boeing 737-100 research aircraft participated in the test. Preliminary results from the primary test set of 24 commercial flights indicate a mean DA arrival time prediction error of 2.4 sec late with a standard deviation of 13.1 sec. This paper describes the field test and presents preliminary results for the commercial flights.

  10. Role of Arrival Time Difference Between Lesions and Lung Tissue on Contrast-Enhanced Sonography in the Differential Diagnosis of Subpleural Pulmonary Lesions.

    PubMed

    Bai, Jing; Yang, Wei; Wang, Song; Guan, Rui-Hong; Zhang, Hui; Fu, Jing-Jing; Wu, Wei; Yan, Kun

    2016-07-01

    The purpose of this study was to explore the diagnostic value of the arrival time difference between lesions and surrounding lung tissue on contrast-enhanced sonography of subpleural pulmonary lesions. A total of 110 patients with subpleural pulmonary lesions who underwent both conventional and contrast-enhanced sonography and had a definite diagnosis were enrolled. After contrast agent injection, the arrival times in the lesion, lung, and chest wall were recorded. The arrival time differences between various tissues were also calculated. Statistical analysis showed a significant difference in the lesion arrival time, the arrival time difference between the lesion and lung, and the arrival time difference between the chest wall and lesion (all P < .001) for benign and malignant lesions. Receiver operating characteristic curve analysis revealed that the optimal diagnostic criterion was the arrival time difference between the lesion and lung, and that the best cutoff point was 2.5 seconds (later arrival signified malignancy). This new diagnostic criterion showed superior diagnostic accuracy (97.1%) compared to conventional diagnostic criteria. The individualized diagnostic method based on an arrival time comparison using contrast-enhanced sonography had high diagnostic accuracy (97.1%) with good feasibility and could provide useful diagnostic information for subpleural pulmonary lesions.

  11. Diagnostic Tools for Acute Anterior Cruciate Ligament Injury: GNRB, Lachman Test, and Telos.

    PubMed

    Ryu, Seung Min; Na, Ho Dong; Shon, Oog Jin

    2018-06-01

    The purpose of this study is to compare the accuracy of the GNRB arthrometer (Genourob), Lachman test, and Telos device (GmbH) in acute anterior cruciate ligament (ACL) injuries and to evaluate the accuracy of each diagnostic tool according to the length of time from injury to examination. From September 2015 to September 2016, 40 cases of complete ACL rupture were reviewed. We divided the time from injury to examination into three periods of 10 days each and analyzed the diagnostic tools according to the time frame. An analysis of the area under the curve (AUC) of a receiver operating characteristic curve showed that all diagnostic tools were fairly informative. The GNRB showed a higher AUC than other diagnostic tools. In 10 cases assessed within 10 days after injury, the GNRB showed statistically significant side-to-side difference in laxity (p<0.001), whereas the Telos test and Lachman test did not show significantly different laxity (p=0.541 and p=0.413, respectively). All diagnostic values of the GNRB were better than other diagnostic tools in acute ACL injuries. The GNRB was more effective in acute ACL injuries examined within 10 days of injury. The GNRB arthrometer can be a useful diagnostic tool for acute ACL injuries.

  12. The Discriminant Accuracy of a Grammatical Measure with Latino English-Speaking Children

    ERIC Educational Resources Information Center

    Gutierrez-Clellen, Vera F.; Simon-Cereijido, Gabriela

    2007-01-01

    Purpose: To evaluate the discriminant accuracy of a grammatical measure for the identification of language impairment (LI) in Latino English-speaking children. Specifically, the study examined the diagnostic accuracy of the Test of English Morphosyntax (E-MST; Pena, Gutierrez-Clellen, Iglesias, Goldstein, & Bedore (n.d.) to determine (a)…

  13. Diagnostic Capability of Biological Markers in Assessment of Obstructive Sleep Apnea: A Systematic Review and Meta-Analysis

    PubMed Central

    De Luca Canto, Graziela; Pachêco-Pereira, Camila; Aydinoz, Secil; Major, Paul W.; Flores-Mir, Carlos; Gozal, David

    2015-01-01

    Objective: The purpose of this systematic review is to evaluate the diagnostic value of biological markers (exhaled breath condensate, blood, salivary and urinary) in the diagnosis of OSA in comparison to the gold standard of nocturnal PSG. Methods: Studies that differentiated OSA from controls based on PSG results, without age restriction, were eligible for inclusion. The sample of selected studies could include studies in obese patients and with known cardiac disease. A detailed individual search strategy for each of the following bibliographic databases was developed: Cochrane, EMBASE, MEDLINE, PubMed, and LILACS. The references cited in these articles were also crosschecked and a partial grey literature search was undertaken using Google Scholar. The methodology of selected studies was evaluated using the 14-item Quality Assessment Tool for Diagnostic Accuracy Studies. Results: After a two-step selection process, nine articles were identified and subjected to qualitative and quantitative analyses. Among them, only one study conducted in children and one in adults found biomarkers that exhibit sufficiently satisfactory diagnostic accuracy that enables application as a diagnostic method for OSA. Conclusion: Kallikrein-1, uromodulin, urocotin-3, and orosomucoid-1 when combined have enough accuracy to be an OSA diagnostic test in children. IL-6 and IL-10 plasma levels have potential to be good biomarkers in identifying or excluding the presence of OSA in adults. Citation: De Luca Canto G, Pachêco-Pereira C, Aydinoz S, Major PW, Flores-Mir C, Gozal D. Diagnostic capability of biological markers in assessment of obstructive sleep apnea: a systematic review and meta-analysis. J Clin Sleep Med 2015;11(1):27–36. PMID:25325575

  14. Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study.

    PubMed

    Bongartz, Tim; Glazebrook, Katrina N; Kavros, Steven J; Murthy, Naveen S; Merry, Stephen P; Franz, Walter B; Michet, Clement J; Veetil, Barath M Akkara; Davis, John M; Mason, Thomas G; Warrington, Kenneth J; Ytterberg, Steven R; Matteson, Eric L; Crowson, Cynthia S; Leng, Shuai; McCollough, Cynthia H

    2015-06-01

    To assess the accuracy of dual-energy CT (DECT) for diagnosing gout, and to explore whether it can have any impact on clinical decision making beyond the established diagnostic approach using polarising microscopy of synovial fluid (diagnostic yield). Diagnostic single-centre study of 40 patients with active gout, and 41 individuals with other types of joint disease. Sensitivity and specificity of DECT for diagnosing gout was calculated against a combined reference standard (polarising and electron microscopy of synovial fluid). To explore the diagnostic yield of DECT scanning, a third cohort was assembled consisting of patients with inflammatory arthritis and risk factors for gout who had negative synovial fluid polarising microscopy results. Among these patients, the proportion of subjects with DECT findings indicating a diagnosis of gout was assessed. The sensitivity and specificity of DECT for diagnosing gout was 0.90 (95% CI 0.76 to 0.97) and 0.83 (95% CI 0.68 to 0.93), respectively. All false negative patients were observed among patients with acute, recent-onset gout. All false positive patients had advanced knee osteoarthritis. DECT in the diagnostic yield cohort revealed evidence of uric acid deposition in 14 out of 30 patients (46.7%). DECT provides good diagnostic accuracy for detection of monosodium urate (MSU) deposits in patients with gout. However, sensitivity is lower in patients with recent-onset disease. DECT has a significant impact on clinical decision making when gout is suspected, but polarising microscopy of synovial fluid fails to demonstrate the presence of MSU crystals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Nearest clusters based partial least squares discriminant analysis for the classification of spectral data.

    PubMed

    Song, Weiran; Wang, Hui; Maguire, Paul; Nibouche, Omar

    2018-06-07

    Partial Least Squares Discriminant Analysis (PLS-DA) is one of the most effective multivariate analysis methods for spectral data analysis, which extracts latent variables and uses them to predict responses. In particular, it is an effective method for handling high-dimensional and collinear spectral data. However, PLS-DA does not explicitly address data multimodality, i.e., within-class multimodal distribution of data. In this paper, we present a novel method termed nearest clusters based PLS-DA (NCPLS-DA) for addressing the multimodality and nonlinearity issues explicitly and improving the performance of PLS-DA on spectral data classification. The new method applies hierarchical clustering to divide samples into clusters and calculates the corresponding centre of every cluster. For a given query point, only clusters whose centres are nearest to such a query point are used for PLS-DA. Such a method can provide a simple and effective tool for separating multimodal and nonlinear classes into clusters which are locally linear and unimodal. Experimental results on 17 datasets, including 12 UCI and 5 spectral datasets, show that NCPLS-DA can outperform 4 baseline methods, namely, PLS-DA, kernel PLS-DA, local PLS-DA and k-NN, achieving the highest classification accuracy most of the time. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Fully-automated identification of fish species based on otolith contour: using short-time Fourier transform and discriminant analysis (STFT-DA).

    PubMed

    Salimi, Nima; Loh, Kar Hoe; Kaur Dhillon, Sarinder; Chong, Ving Ching

    2016-01-01

    Background. Fish species may be identified based on their unique otolith shape or contour. Several pattern recognition methods have been proposed to classify fish species through morphological features of the otolith contours. However, there has been no fully-automated species identification model with the accuracy higher than 80%. The purpose of the current study is to develop a fully-automated model, based on the otolith contours, to identify the fish species with the high classification accuracy. Methods. Images of the right sagittal otoliths of 14 fish species from three families namely Sciaenidae, Ariidae, and Engraulidae were used to develop the proposed identification model. Short-time Fourier transform (STFT) was used, for the first time in the area of otolith shape analysis, to extract important features of the otolith contours. Discriminant Analysis (DA), as a classification technique, was used to train and test the model based on the extracted features. Results. Performance of the model was demonstrated using species from three families separately, as well as all species combined. Overall classification accuracy of the model was greater than 90% for all cases. In addition, effects of STFT variables on the performance of the identification model were explored in this study. Conclusions. Short-time Fourier transform could determine important features of the otolith outlines. The fully-automated model proposed in this study (STFT-DA) could predict species of an unknown specimen with acceptable identification accuracy. The model codes can be accessed at http://mybiodiversityontologies.um.edu.my/Otolith/ and https://peerj.com/preprints/1517/. The current model has flexibility to be used for more species and families in future studies.

  17. Diagnostic accuracy of transabdominal high-resolution US for staging gallbladder cancer and differential diagnosis of neoplastic polyps compared with EUS.

    PubMed

    Lee, Jeong Sub; Kim, Jung Hoon; Kim, Yong Jae; Ryu, Ji Kon; Kim, Yong-Tae; Lee, Jae Young; Han, Joon Koo

    2017-07-01

    To compare the diagnostic accuracy of transabdominal high-resolution ultrasound (HRUS) for staging gallbladder cancer and differential diagnosis of neoplastic polyps compared with endoscopic ultrasound (EUS) and pathology. Among 125 patients who underwent both HRUS and EUS, we included 29 pathologically proven cancers (T1 = 7, T2 = 19, T3 = 3) including 15 polypoid cancers and 50 surgically proven polyps (neoplastic = 30, non-neoplastic = 20). We reviewed formal reports and assessed the accuracy of HRUS and EUS for diagnosing cancer as well as the differential diagnosis of neoplastic polyps. Statistical analyses were performed using chi-square tests. The sensitivity, specificity, PPV, and NPV for gallbladder cancer were 82.7 %, 44.4 %, 82.7 %, and 44 % using HRUS and 86.2 %, 22.2 %, 78.1 %, and 33.3 % using EUS. HRUS and EUS correctly diagnosed the stage in 13 and 12 patients. The sensitivity, specificity, PPV, and NPV for neoplastic polyps were 80 %, 80 %, 86 %, and 73 % using HRUS and 73 %, 85 %, 88 %, and 69 % using EUS. Single polyps (8/20 vs. 21/30), larger (1.0 ± 0.28 cm vs. 1.9 ± 0.85 cm) polyps, and older age (52.5 ± 13.2 vs. 66.1 ± 10.3 years) were common in neoplastic polyps (p < 0.05). Transabdominal HRUS showed comparable accuracy for diagnosing gallbladder cancer and differentiating neoplastic polyps compared with EUS. HRUS is also easy to use during our routine ultrasound examinations. • HRUS showed comparable diagnostic accuracy for GB cancer compared with EUS. • HRUS and EUS showed similar diagnostic accuracy for differentiating neoplastic polyps. • Single, larger polyps and older age were common in neoplastic polyps. • HRUS is less invasive compared with EUS.

  18. Overinterpretation and misreporting of diagnostic accuracy studies: evidence of "spin".

    PubMed

    Ochodo, Eleanor A; de Haan, Margriet C; Reitsma, Johannes B; Hooft, Lotty; Bossuyt, Patrick M; Leeflang, Mariska M G

    2013-05-01

    To estimate the frequency of distorted presentation and overinterpretation of results in diagnostic accuracy studies. MEDLINE was searched for diagnostic accuracy studies published between January and June 2010 in journals with an impact factor of 4 or higher. Articles included were primary studies of the accuracy of one or more tests in which the results were compared with a clinical reference standard. Two authors scored each article independently by using a pretested data-extraction form to identify actual overinterpretation and practices that facilitate overinterpretation, such as incomplete reporting of study methods or the use of inappropriate methods (potential overinterpretation). The frequency of overinterpretation was estimated in all studies and in a subgroup of imaging studies. Of the 126 articles, 39 (31%; 95% confidence interval [CI]: 23, 39) contained a form of actual overinterpretation, including 29 (23%; 95% CI: 16, 30) with an overly optimistic abstract, 10 (8%; 96% CI: 3%, 13%) with a discrepancy between the study aim and conclusion, and eight with conclusions based on selected subgroups. In our analysis of potential overinterpretation, authors of 89% (95% CI: 83%, 94%) of the studies did not include a sample size calculation, 88% (95% CI: 82%, 94%) did not state a test hypothesis, and 57% (95% CI: 48%, 66%) did not report CIs of accuracy measurements. In 43% (95% CI: 34%, 52%) of studies, authors were unclear about the intended role of the test, and in 3% (95% CI: 0%, 6%) they used inappropriate statistical tests. A subgroup analysis of imaging studies showed 16 (30%; 95% CI: 17%, 43%) and 53 (100%; 95% CI: 92%, 100%) contained forms of actual and potential overinterpretation, respectively. Overinterpretation and misreporting of results in diagnostic accuracy studies is frequent in journals with high impact factors. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120527/-/DC1. © RSNA, 2013.

  19. Accuracy, image quality, and radiation dose of prospectively ECG-triggered high-pitch dual-source CT angiography in infants and children with complex coarctation of the aorta.

    PubMed

    Xu, Jian; Zhao, Hongliang; Wang, Xiaoying; Bai, Yuxiang; Liu, Liwen; Liu, Ying; Wei, Mengqi; Li, Jian; Zheng, Minwen

    2014-10-01

    To evaluate the diagnostic accuracy, image quality, and radiation dose of prospective electrocardiogram (ECG)-triggered high-pitch dual-source computed tomography (DSCT) in infants and young children with complex coarctation of the aorta (CoA). Forty pediatric patients aged < 4 years with suspected CoA underwent prospective ECG-triggered high-pitch DSCT angiography and transthoracic echocardiography (TTE). Surgery and/or conventional cardiac angiography (CCA) were performed in all patients. The diagnostic accuracy of DSCT angiography and TTE was compared to the surgical and/or CCA findings. The causes of misdiagnosis and miss were analyzed, and the advantages and limitation of both imaging modalities were evaluated. Image quality of DSCT was evaluated, and effective radiation dose was calculated. The sensitivity, specificity, positive predictive value, negative predictive value, and overall diagnostic accuracy of DSCT in evaluation of complex CoA were 92.37%, 98.51%, 97.32%, 93.57%, and 96.25%, respectively. There was a significant difference in the accuracy between DSCT and TTE (χ² = 9.9, P<.05). For a total of 80 extracardiac anomalies, the sensitivity (98.8%, 79/80) of DSCT was greater than that of TTE (62.5%; 50 of 80). On the contrary, for 38 cardiac anomalies, the sensitivity (78.9%, 30 of 38) of DSCT was lesser than that of TTE (100%; 38 of 38). The mean score of image quality was 4.27 ± 0.73. The mean effective radiation dose was 0.20 ± 0.09 mSv. Prospective ECG-triggered high-pitch DSCT may be a clinical feasible modality in the evaluation of pediatric patients with complex CoA, providing adequate image quality, high diagnostic accuracy, and low radiation dose. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  20. Accuracy of cystatin C for the detection of abnormal renal function in children undergoing chemotherapy for malignancy: a systematic review using individual patient data.

    PubMed

    Whiting, Penny; Birnie, Kate; Sterne, Jonathan A C; Jameson, Catherine; Skinner, Rod; Phillips, Bob

    2018-05-01

    We conducted a systematic review and individual patient data (IPD) meta-analysis to examine the utility of cystatin C for evaluation of glomerular function in children with cancer. Eligible studies evaluated the accuracy of cystatin C for detecting poor renal function in children undergoing chemotherapy. Study quality was assessed using QUADAS-2. Authors of four studies shared IPD. We calculated the correlation between log cystatin C and GFR stratified by study and measure of cystatin C. We dichotomized the reference standard at GFR 80 ml/min/1.73m 2 and stratified cystatin C at 1 mg/l, to calculate sensitivity and specificity in each study and according to age group (0-4, 5-12, and ≥ 13 years). In sensitivity analyses, we investigated different GFR and cystatin C cut points. We used logistic regression to estimate the association of impaired renal function with log cystatin C and quantified diagnostic accuracy using the area under the ROC curve (AUC). Six studies, which used different test and reference standard thresholds, suggested that cystatin C has the potential to monitor renal function in children undergoing chemotherapy for malignancy. IPD data (504 samples, 209 children) showed that cystatin C has poor sensitivity (63%) and moderate specificity (89%), although use of a GFR cut point of < 60 ml/min/1.73m 2 (data only available from two of the studies) estimated sensitivity to be 92% and specificity 81.3%. The AUC for the combined data set was 0.890 (95% CI 0.826, 0.951). Diagnostic accuracy appeared to decrease with age. Cystatin C has better diagnostic accuracy than creatinine as a test for glomerular dysfunction in young people undergoing treatment for cancer. Diagnostic accuracy is not sufficient for it to replace current reference standards for predicting clinically relevant impairments that may alter dosing of important nephrotoxic agents.

  1. Comparative analysis of ERCP, IDUS, EUS and CT in predicting malignant bile duct strictures

    PubMed Central

    Heinzow, Hauke S; Kammerer, Sara; Rammes, Carina; Wessling, Johannes; Domagk, Dirk; Meister, Tobias

    2014-01-01

    AIM: To compare endoscopic retrograde cholangio-pancreatography (ERCP), intraductal ultrasound (IDUS), endosonography (EUS), endoscopic transpapillary forceps biopsies (ETP) and computed tomography (CT) with respect to diagnosing malignant bile duct strictures. METHODS: A patient cohort with bile duct strictures of unknown etiology was examined by ERCP and IDUS, ETP, EUS, and CT. The sensitivity, specificity, and accuracy rates of the diagnostic procedures were calculated based on the definite diagnoses proved by histopathology or long-term follow-up in those patients who did not undergo surgery. For each of the diagnostic measures, the sensitivity, specificity, and accuracy rates were calculated. In all cases, the gold standard was the histopathologic staging of specimens or long-term follow-up of at least 12 mo. A comparison of the accuracy rates between the localization of strictures was performed by using the Mann-Whitney U-test and the χ2 test as appropriate. A comparison of the accuracy rates between the diagnostic procedures was performed by using the McNemar’s test. Differences were considered statistically significant if P < 0.05. RESULTS: A total of 234 patients (127 males, 107 females, median age 64, range 20-90 years) with indeterminate bile duct strictures were included. A total of 161 patients underwent operative exploration; thus, a surgical histopathological correlation was available for those patients. A total of 113 patients had malignant disease proven by surgery; in 48 patients, benign disease was surgically found. In these patients, the decision for surgical exploration was made due to the suspicion of malignant disease in multimodal diagnostics (ERCP, CT, or EUS). Fifty patients had a benign diagnosis and were followed by a surveillance protocol with a follow-up of at least 12 mo; the median follow-up was 34 mo. Twenty-three patients had extended malignant disease, and thus were considered palliative. A comparison of the different diagnostic tools for detecting bile duct malignancy resulted in accuracy rates of 91% (ERCP/IDUS), 59% (ETP), 92% (IDUS + ETP), 74% (EUS), and 73% (CT), respectively. In the subgroup analysis, the accuracy rates (%, ERCP + IDUS/ETP/IDUS + ETP; EUS; CT) for each tumor entity were as follows: cholangiocellular carcinoma: 92%/74%/92%/70%/79%; pancreatic carcinoma: 90%/68%/90%/81%/76%; and ampullary carcinoma: 88%/90%/90%/76%/76%. The detection rate of malignancy by ERCP/IDUS was superior to ETP (91% vs 59%, P < 0.0001), EUS (91% vs 74%, P < 0.0001) and CT (91% vs 73%, P < 0.0001); EUS was comparable to CT (74% vs 73%, P = 0.649). When analyzing accuracy rates with regard to localization of the bile duct stenosis, the accuracy rate of EUS for proximal vs distal stenosis was significantly higher for distal stenosis (79% vs 57%, P < 0.0001). CONCLUSION: ERCP/IDUS is superior to EUS and CT in providing accurate diagnoses of bile duct strictures of uncertain etiology. Multimodal diagnostics is recommended. PMID:25132767

  2. Accuracy of Neck stiffness, Kernig, Brudzinski, and Jolt Accentuation of Headache Signs in Early Detection of Meningitis.

    PubMed

    Ala, Alireza; Rahmani, Farzad; Abdollahi, Sima; Parsian, Zahra

    2018-01-01

    The diagnostic value of clinical signs in early diagnosis of meningitis has been evaluated but the existing results are contradicting. The present study aimed to evaluate the accuracy of Kernig, Brudzinski, neck stiffness, and Jolt Accentuation of Headache (JAH) signs in this regard. In this diagnostic accuracy study, patients with suspected meningitis who were referred to the emergency department were examined regarding presence or absence of the mentioned clinical signs and screening performance characteristics of the signs were calculated. Cerebrospinal fluid analysis was used as the reference test. 120 cases with mean age of 48.79 ± 21.68 years (18 - 93) were studied (63.3% male). Diagnosis of meningitis was confirmed for 45 (37.5%) cases. Neck stiffness (p < 0.001), Kernig (p < 0.001), Brudzinski (p < 0.001), and JAH (p < 0.001) had significantly higher frequency among patients with meningitis. The accuracy of neck stiffness, Kernig, Brudzinski, and JAH signs in early detection of meningitis were 0.676 (95% CI: 0.575-0.776), 0.667 (95% CI: 0.552-0.782), 0.720 (95% CI: 0.619-0.821), 0.749 (95% CI: 0.659-839), respectively. It seems that diagnostic value of JAH is higher than other clinical signs but the accuracy of all signs is in poor to fair range. JAH had the highest sensitivity and Kernig and Brudzinski had the highest specificity.

  3. Imaging modalities in the diagnosis of pancreatic adenocarcinoma: A systematic review and meta-analysis of sensitivity, specificity and diagnostic accuracy.

    PubMed

    Toft, James; Hadden, William J; Laurence, Jerome M; Lam, Vincent; Yuen, Lawrence; Janssen, Anna; Pleass, Henry

    2017-07-01

    Pancreatic cancer, primarily pancreatic ductal adenocarcinoma (PDAC), accounts for 2.4% of cancer diagnoses and 5.8% of cancer death annually. Early diagnoses can improve 5-year survival in PDAC. The aim of this systematic review was to determine the sensitivity, specificity and diagnostic accuracy values for MRI, CT, PET&PET/CT, EUS and transabdominal ultrasound (TAUS) in the diagnosis of PDAC. A systematic review was undertaken to identify studies reporting sensitivity, specificity and/or diagnostic accuracy for the diagnosis of PDAC with MRI, CT, PET, EUS or TAUS. Proportional meta-analysis was performed for each modality. A total of 5399 patients, 3567 with PDAC, from 52 studies were included. The sensitivity, specificity and diagnostic accuracy were 93% (95% CI=88-96), 89% (95% CI=82-94) and 90% (95% CI=86-94) for MRI; 90% (95% CI=87-93), 87% (95% CI=79-93) and 89% (95% CI=85-93) for CT; 89% (95% CI=85-93), 70% (95% CI=54-84) and 84% (95% CI=79-89) for PET; 91% (95% CI=87-94), 86% (95% CI=81-91) and 89% (95% CI=87-92) for EUS; and 88% (95% CI=86-90), 94% (95% CI=87-98) and 91% (95% C=87-93) for TAUS. This review concludes all modalities, except for PET, are equivalent within 95% confidence intervals for the diagnosis of PDAC. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Predictive capabilities of statistical learning methods for lung nodule malignancy classification using diagnostic image features: an investigation using the Lung Image Database Consortium dataset

    NASA Astrophysics Data System (ADS)

    Hancock, Matthew C.; Magnan, Jerry F.

    2017-03-01

    To determine the potential usefulness of quantified diagnostic image features as inputs to a CAD system, we investigate the predictive capabilities of statistical learning methods for classifying nodule malignancy, utilizing the Lung Image Database Consortium (LIDC) dataset, and only employ the radiologist-assigned diagnostic feature values for the lung nodules therein, as well as our derived estimates of the diameter and volume of the nodules from the radiologists' annotations. We calculate theoretical upper bounds on the classification accuracy that is achievable by an ideal classifier that only uses the radiologist-assigned feature values, and we obtain an accuracy of 85.74 (+/-1.14)% which is, on average, 4.43% below the theoretical maximum of 90.17%. The corresponding area-under-the-curve (AUC) score is 0.932 (+/-0.012), which increases to 0.949 (+/-0.007) when diameter and volume features are included, along with the accuracy to 88.08 (+/-1.11)%. Our results are comparable to those in the literature that use algorithmically-derived image-based features, which supports our hypothesis that lung nodules can be classified as malignant or benign using only quantified, diagnostic image features, and indicates the competitiveness of this approach. We also analyze how the classification accuracy depends on specific features, and feature subsets, and we rank the features according to their predictive power, statistically demonstrating the top four to be spiculation, lobulation, subtlety, and calcification.

  5. Validation of consensus panel diagnosis in dementia.

    PubMed

    Gabel, Matthew J; Foster, Norman L; Heidebrink, Judith L; Higdon, Roger; Aizenstein, Howard J; Arnold, Steven E; Barbas, Nancy R; Boeve, Bradley F; Burke, James R; Clark, Christopher M; Dekosky, Steven T; Farlow, Martin R; Jagust, William J; Kawas, Claudia H; Koeppe, Robert A; Leverenz, James B; Lipton, Anne M; Peskind, Elaine R; Turner, R Scott; Womack, Kyle B; Zamrini, Edward Y

    2010-12-01

    The clinical diagnosis of dementing diseases largely depends on the subjective interpretation of patient symptoms. Consensus panels are frequently used in research to determine diagnoses when definitive pathologic findings are unavailable. Nevertheless, research on group decision making indicates that many factors can adversely affect panel performance. To determine conditions that improve consensus panel diagnosis. Comparison of neuropathologic diagnoses with individual and consensus panel diagnoses based on clinical scenarios only, fludeoxyglucose F 18 positron emission tomography images only, and scenarios plus images. Expert and trainee individual and consensus panel deliberations using a modified Delphi method in a pilot research study of the diagnostic utility of fludeoxyglucose F 18 positron emission tomography. Forty-five patients with pathologically confirmed Alzheimer disease or frontotemporal dementia. Statistical measures of diagnostic accuracy, agreement, and confidence for individual raters and panelists before and after consensus deliberations. The consensus protocol using trainees and experts surpassed the accuracy of individual expert diagnoses when clinical information elicited diverse judgments. In these situations, consensus was 3.5 times more likely to produce positive rather than negative changes in the accuracy and diagnostic certainty of individual panelists. A rule that forced group consensus was at least as accurate as majority and unanimity rules. Using a modified Delphi protocol to arrive at a consensus diagnosis is a reasonable substitute for pathologic information. This protocol improves diagnostic accuracy and certainty when panelist judgments differ and is easily adapted to other research and clinical settings while avoiding the potential pitfalls of group decision making.

  6. Improved Diagnostic Accuracy of Alzheimer's Disease by Combining Regional Cortical Thickness and Default Mode Network Functional Connectivity: Validated in the Alzheimer's Disease Neuroimaging Initiative Set.

    PubMed

    Park, Ji Eun; Park, Bumwoo; Kim, Sang Joon; Kim, Ho Sung; Choi, Choong Gon; Jung, Seung Chai; Oh, Joo Young; Lee, Jae-Hong; Roh, Jee Hoon; Shim, Woo Hyun

    2017-01-01

    To identify potential imaging biomarkers of Alzheimer's disease by combining brain cortical thickness (CThk) and functional connectivity and to validate this model's diagnostic accuracy in a validation set. Data from 98 subjects was retrospectively reviewed, including a study set (n = 63) and a validation set from the Alzheimer's Disease Neuroimaging Initiative (n = 35). From each subject, data for CThk and functional connectivity of the default mode network was extracted from structural T1-weighted and resting-state functional magnetic resonance imaging. Cortical regions with significant differences between patients and healthy controls in the correlation of CThk and functional connectivity were identified in the study set. The diagnostic accuracy of functional connectivity measures combined with CThk in the identified regions was evaluated against that in the medial temporal lobes using the validation set and application of a support vector machine. Group-wise differences in the correlation of CThk and default mode network functional connectivity were identified in the superior temporal ( p < 0.001) and supramarginal gyrus ( p = 0.007) of the left cerebral hemisphere. Default mode network functional connectivity combined with the CThk of those two regions were more accurate than that combined with the CThk of both medial temporal lobes (91.7% vs. 75%). Combining functional information with CThk of the superior temporal and supramarginal gyri in the left cerebral hemisphere improves diagnostic accuracy, making it a potential imaging biomarker for Alzheimer's disease.

  7. Accuracy of iodine quantification in dual-layer spectral CT: Influence of iterative reconstruction, patient habitus and tube parameters.

    PubMed

    Sauter, Andreas P; Kopp, Felix K; Münzel, Daniela; Dangelmaier, Julia; Renz, Martin; Renger, Bernhard; Braren, Rickmer; Fingerle, Alexander A; Rummeny, Ernst J; Noël, Peter B

    2018-05-01

    Evaluation of the influence of iterative reconstruction, tube settings and patient habitus on the accuracy of iodine quantification with dual-layer spectral CT (DL-CT). A CT abdomen phantom with different extension rings and four iodine inserts (1, 2, 5 and 10 mg/ml) was scanned on a DL-CT. The phantom was scanned with tube-voltages of 120 and 140 kVp and CTDI vol of 2.5, 5, 10 and 20 mGy. Reconstructions were performed for eight levels of iterative reconstruction (i0-i7). Diagnostic dose levels are classified depending on patient-size and radiation dose. Measurements of iodine concentration showed accurate and reliable results. Taking all CTDI vol -levels into account, the mean absolute percentage difference (MAPD) showed less accuracy for low CTDI vol -levels (2.5 mGy: 34.72%) than for high CTDI vol -levels (20 mGy: 5.89%). At diagnostic dose levels, accurate quantification of iodine was possible (MAPD 3.38%). Level of iterative reconstruction did not significantly influence iodine measurements. Iodine quantification worked more accurately at a tube voltage of 140 kVp. Phantom size had a considerable effect only at low-dose-levels; at diagnostic dose levels the effect of phantom size decreased (MAPD <5% for all phantom sizes). With DL-CT, even low iodine concentrations can be accurately quantified. Accuracies are higher when diagnostic radiation doses are employed. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Assessment of colon polyp morphology: Is education effective?

    PubMed Central

    Kim, Jae Hyun; Nam, Kyoung Sik; Kwon, Hye Jung; Choi, Youn Jung; Jung, Kyoungwon; Kim, Sung Eun; Moon, Won; Park, Moo In; Park, Seun Ja

    2017-01-01

    AIM To determine the inter-observer variability for colon polyp morphology and to identify whether education can improve agreement among observers. METHODS For purposes of the tests, we recorded colonoscopy video clips that included scenes visualizing the polyps. A total of 15 endoscopists and 15 nurses participated in the study. Participants watched 60 video clips of the polyp morphology scenes and then estimated polyp morphology (pre-test). After education for 20 min, participants performed a second test in which the order of 60 video clips was changed (post-test). To determine if the effectiveness of education was sustained, four months later, a third, follow-up test was performed with the same participants. RESULTS The overall Fleiss’ kappa value of the inter-observer agreement was 0.510 in the pre-test, 0.618 in the post-test, and 0.580 in the follow-up test. The overall diagnostic accuracy of the estimation for polyp morphology in the pre-, post-, and follow-up tests was 0.662, 0.797, and 0.761, respectively. After education, the inter-observer agreement and diagnostic accuracy of all participants improved. However, after four months, the inter-observer agreement and diagnostic accuracy of expert groups were markedly decreased, and those of beginner and nurse groups remained similar to pre-test levels. CONCLUSION The education program used in this study can improve inter-observer agreement and diagnostic accuracy in assessing the morphology of colon polyps; it is especially effective when first learning endoscopy. PMID:28974894

  9. A randomized trial to determine the diagnostic accuracy of conventional vs. jumbo forceps biopsy of gastric epithelial neoplasias before endoscopic submucosal dissection; open-label study.

    PubMed

    Jeon, Hyo Keun; Ryu, Ho Yoel; Cho, Mee Yon; Kim, Hyun-Soo; Kim, Jae Woo; Park, Hong Jun; Kim, Moon Young; Baik, Soon Koo; Kwon, Sang Ok; Park, Su Yeon; Won, Sung Ho

    2014-10-01

    Larger biopsy specimens or increasing the number of biopsies may improve the diagnostic accuracy of gastric epithelial neoplasia (GEN). The aims of this study was to compare the diagnostic accuracies between conventional and jumbo forceps biopsy of GEN before endoscopic submucosal dissection (ESD) and to confirm that increasing the number of biopsies is useful for the diagnosis of GEN. The concordance rate between EFB and ESD specimens was not significantly different between the two groups [83.1 % (54/65) in JG vs. 79.1 % (53/67) in CG]. On multivariate analyses, two or four EFBs significantly increased the cumulating concordance rate [coefficients; twice: 5.1 (P = 0.01), four times: 5.9 (P = 0.02)]. But, the concordance rate was decreased in high grade dysplasia (coefficient -40.32, P = 0.006). One hundred and sixty GENs from 148 patients were randomized into two groups and finally 67 GENs in 61 patients and 65 GENs in 63 patients were allocated to the conventional group (CG) or jumbo group (JG), respectively. Four endoscopic forceps biopsy (EFB) specimens were obtained from each lesion with conventional (6.8 mm) forceps or jumbo (8 mm) forceps. The histological concordance rate between 4 EFB specimens and ESD specimens was investigated in the two groups. Before ESD, the diagnostic accuracy of GENs was significantly increased not by the use of jumbo forceps biopsy but by increasing the number of biopsies.

  10. Diagnostic Accuracy of Memory Measures in Alzheimer’s Dementia and Mild Cognitive Impairment: a Systematic Review and Meta-Analysis

    PubMed Central

    Weissberger, Gali H.; Strong, Jessica V.; Stefanidis, Kayla B.; Summers, Mathew J.; Bondi, Mark W.; Stricker, Nikki H.

    2018-01-01

    With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer’s dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer’s disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers. PMID:28940127

  11. Assessment of colon polyp morphology: Is education effective?

    PubMed

    Kim, Jae Hyun; Nam, Kyoung Sik; Kwon, Hye Jung; Choi, Youn Jung; Jung, Kyoungwon; Kim, Sung Eun; Moon, Won; Park, Moo In; Park, Seun Ja

    2017-09-14

    To determine the inter-observer variability for colon polyp morphology and to identify whether education can improve agreement among observers. For purposes of the tests, we recorded colonoscopy video clips that included scenes visualizing the polyps. A total of 15 endoscopists and 15 nurses participated in the study. Participants watched 60 video clips of the polyp morphology scenes and then estimated polyp morphology (pre-test). After education for 20 min, participants performed a second test in which the order of 60 video clips was changed (post-test). To determine if the effectiveness of education was sustained, four months later, a third, follow-up test was performed with the same participants. The overall Fleiss' kappa value of the inter-observer agreement was 0.510 in the pre-test, 0.618 in the post-test, and 0.580 in the follow-up test. The overall diagnostic accuracy of the estimation for polyp morphology in the pre-, post-, and follow-up tests was 0.662, 0.797, and 0.761, respectively. After education, the inter-observer agreement and diagnostic accuracy of all participants improved. However, after four months, the inter-observer agreement and diagnostic accuracy of expert groups were markedly decreased, and those of beginner and nurse groups remained similar to pre-test levels. The education program used in this study can improve inter-observer agreement and diagnostic accuracy in assessing the morphology of colon polyps; it is especially effective when first learning endoscopy.

  12. Comparison of digital tomosynthesis and chest radiography for the detection of pulmonary nodules: systematic review and meta-analysis

    PubMed Central

    Kim, Jun H; Lee, Kyung H; Kim, Kyoung-Tae; Ahn, Hyeong S; Kim, Yeo J; Lee, Ha Y; Jeon, Yong S

    2016-01-01

    Objective: To compare the diagnostic accuracy of digital tomosynthesis (DTS) with that of chest radiography for the detection of pulmonary nodules by meta-analysis. Methods: A systematic literature search was performed to identify relevant original studies from 1 January 1 1976 to 31 August 31 2016. The quality of included studies was assessed by quality assessment of diagnostic accuracy studies-2. Per-patient data were used to calculate the sensitivity and specificity and per-lesion data were used to calculate the detection rate. Summary receiver-operating characteristic curves were drawn for pulmonary nodule detection. Results: 16 studies met the inclusion criteria. 1017 patients on a per-patient basis and 2159 lesions on a per-lesion basis from 16 eligible studies were evaluated. The pooled patient-based sensitivity of DTS was 0.85 [95% confidence interval (CI) 0.83–0.88] and the specificity was 0.95 (0.93–0.96). The pooled sensitivity and specificity of chest radiography were 0.47 (0.44–0.51) and 0.37 (0.34–0.40), respectively. The per-lesion detection rate was 2.90 (95% CI 2.63–3.19). Conclusion: DTS has higher diagnostic accuracy than chest radiography for detection of pulmonary nodules. Chest radiography has low sensitivity but similar specificity, comparable with that of DTS. Advances in knowledge: DTS has higher diagnostic accuracy than chest radiography for the detection of pulmonary nodules. PMID:27759428

  13. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.

    PubMed Central

    Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen

    2006-01-01

    OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726

  14. New diagnostic modalities in the diagnosis of heart failure.

    PubMed Central

    Mitchell, Judith E.; Palta, Sanjeev

    2004-01-01

    Heart failure (HF) is the one cardiovascular disease that is increasing in prevalence in the United States. As the population continues to age, the incidence will certainly be amplified. However, some studies have shown that HF is correctly diagnosed initially in only 50% of affected patients. Despite the use of history, physical examination, echocardiogram, and chest x-ray, the percentage of correct initial diagnosis of HF is low. Recognizing the symptoms of HF decompensations is often problematic because other diagnoses can mimic them. There are two new diagnostic modalities that offer promise in improving HF diagnostic accuracy and identifying early HF decompensations. These diagnostic modalities include tests utilizing impedance cardiography and the B-type natriuretic peptide assay. They have the potential of increasing the accuracy of HF diagnosis and guide pharmacological treatment in the inpatient and outpatient settings. They may also assist in the recognition (or prediction) of acute HF decompensations. Images Figure 2 PMID:15586645

  15. Diagnostic value of tendon thickness and structure in the sonographic diagnosis of supraspinatus tendinopathy: room for a two-step approach.

    PubMed

    Arend, Carlos Frederico; Arend, Ana Amalia; da Silva, Tiago Rodrigues

    2014-06-01

    The aim of our study was to systematically compare different methodologies to establish an evidence-based approach based on tendon thickness and structure for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. US was obtained from 164 symptomatic patients with supraspinatus tendinopathy detected at MRI and 42 asymptomatic controls with normal MRI. Diagnostic yield was calculated for either maximal supraspinatus tendon thickness (MSTT) and tendon structure as isolated criteria and using different combinations of parallel and sequential testing at US. Chi-squared tests were performed to assess sensitivity, specificity, and accuracy of different diagnostic approaches. Mean MSTT was 6.68 mm in symptomatic patients and 5.61 mm in asymptomatic controls (P<.05). When used as an isolated criterion, MSTT>6.0mm provided best results for accuracy (93.7%) when compared to other measurements of tendon thickness. Also as an isolated criterion, abnormal tendon structure (ATS) yielded 93.2% accuracy for diagnosis. The best overall yield was obtained by both parallel and sequential testing using either MSTT>6.0mm or ATS as diagnostic criteria at no particular order, which provided 99.0% accuracy, 100% sensitivity, and 95.2% specificity. Among these parallel and sequential tests that provided best overall yield, additional analysis revealed that sequential testing first evaluating tendon structure required assessment of 258 criteria (vs. 261 for sequential testing first evaluating tendon thickness and 412 for parallel testing) and demanded a mean of 16.1s to assess diagnostic criteria and reach the diagnosis (vs. 43.3s for sequential testing first evaluating tendon thickness and 47.4s for parallel testing). We found that using either MSTT>6.0mm or ATS as diagnostic criteria for both parallel and sequential testing provides the best overall yield for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. Among these strategies, a two-step sequential approach first assessing tendon structure was advantageous because it required a lower number of criteria to be assessed and demanded less time to assess diagnostic criteria and reach the diagnosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Diagnostic Accuracy of APRI, AAR, FIB-4, FI, King, Lok, Forns, and FibroIndex Scores in Predicting the Presence of Esophageal Varices in Liver Cirrhosis

    PubMed Central

    Deng, Han; Qi, Xingshun; Guo, Xiaozhong

    2015-01-01

    Abstract Aspartate aminotransferase-to-platelet ratio (APRI), aspartate aminotransferase-to-alanine aminotransferase ratio (AAR), FIB-4, FI, King, Lok, Forns, and FibroIndex scores may be simple and convenient noninvasive diagnostic tests, because they are based on the regular laboratory tests and demographic data. This study aimed to systematically evaluate their diagnostic accuracy for the prediction of varices in liver cirrhosis. All relevant papers were searched via PubMed, EMBASE, CNKI, and Wanfang databases. The area under the summary receiver operating characteristic curve (AUSROC), sensitivity, specificity, positive and negative likelihood ratio (PLR and NLR), and diagnostic odds ratio (DOR) were calculated. Overall, 12, 4, 5, 0, 0, 4, 3, and 1 paper was identified to explore the diagnostic accuracy of APRI, AAR, FIB-4, FI, King, Lok, Forns, and FibroIndex scores, respectively. The AUSROCs of APRI, AAR, FIB-4, Lok, and Forns scores for the prediction of varices were 0.6774, 0.7275, 0.7755, 0.7885, and 0.7517, respectively; and those for the prediction of large varices were 0.7278, 0.7448, 0.7095, 0.7264, and 0.6530, respectively. The diagnostic threshold effects of FIB-4 and Forns scores for the prediction of varices were statistically significant. The sensitivities/specificities/PLRs/NLRs/DORs of APRI, AAR, and Lok scores for the prediction of varices were 0.60/0.67/1.77/0.58/3.13, 0.64/0.63/1.97/0.54/4.18, and 0.74/0.68/2.34/0.40/5.76, respectively. The sensitivities/specificities/PLRs/NLRs/DORs of APRI, AAR, FIB-4, Lok, and Forns scores for the prediction of large varices were 0.65/0.66/2.15/0.47/4.97, 0.68/0.58/2.07/0.54/3.93, 0.62/0.64/2.02/0.56/3.57, 0.78/0.63/2.09/0.37/5.55, and 0.65/0.61/1.62/0.59/2.75, respectively. APRI, AAR, FIB-4, Lok, and Forns scores had low to moderate diagnostic accuracy in predicting the presence of varices in liver cirrhosis. PMID:26496312

  17. Diagnostic evaluation of sentinel lymph node biopsy using indocyanine green and infrared or fluorescent imaging in gastric cancer: a systematic review and meta-analysis.

    PubMed

    Skubleny, Daniel; Dang, Jerry T; Skulsky, Samuel; Switzer, Noah; Tian, Chunhong; Shi, Xinzhe; de Gara, Christopher; Birch, Daniel W; Karmali, Shahzeer

    2018-06-01

    Sentinel node navigation surgery (SNNS) for gastric cancer using infrared visualization of indocyanine green (ICG) is intriguing because it may limit operative morbidity. We are the first to systematically review and perform meta-analysis on the diagnostic utility of ICG and infrared electronic endoscopy (IREE) or near infrared fluorescent imaging (NIFI) for SNNS exclusively in gastric cancer. A search of electronic databases MEDLINE, EMBASE, SCOPUS, Web of Science, and the Cochrane Library using search terms "gastric/stomach" AND "tumor/carcinoma/cancer/neoplasm/adenocarcinoma/malignancy" AND "indocyanine green" was completed in May 2017. Articles were selected by two independent reviewers based on the following major inclusion criteria: (1) diagnostic accuracy study design; (2) indocyanine green was injected at tumor site; (3) IREE or NIFI was used for intraoperative visualization. 327 titles or abstracts were screened. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2. Ten full text studies were selected. 643 patients were identified with the majority of patients possessing T1 tumors (79.8%). Pooled identification rate, diagnostic odds ratio, sensitivity, and specificity were 0.99 (0.97-1.0), 380.0 (68.71-2101), 0.87 (0.80-0.93), and 1.00 (0.99-1.00), respectively. The summary receiver operator characteristic for ICG + IREE/NIFI demonstrated a test accuracy of 98.3%. Subgroup analysis found improved test performance for studies with low-risk QUADAS-2 scores, studies published after 2010 and submucosal ICG injection. IREE had improved diagnostic odds ratio, sensitivity, and identification rate compared to NIFI. Heterogeneity among studies ranged from low (I 2  < 25%) to high (I 2  > 75%). We found encouraging results regarding the accuracy, diagnostic odds ratio, and specificity of the test. The sensitivity was not optimal but may be improved by a strict protocol to augment the technique. Given the number and heterogeneity of studies, our results must be viewed with caution.

  18. Tumor acidity-activatable TAT targeted nanomedicine for enlarged fluorescence/magnetic resonance imaging-guided photodynamic therapy.

    PubMed

    Gao, Meng; Fan, Feng; Li, Dongdong; Yu, Yue; Mao, Kuirong; Sun, Tianmeng; Qian, Haisheng; Tao, Wei; Yang, Xianzhu

    2017-07-01

    Nanoparticles simultaneously integrated the photosensitizers and diagnostic agents represent an emerging approach for imaging-guided photodynamic therapy (PDT). However, the diagnostic sensitivity and therapeutic efficacy of nanoparticles as well as the heterogeneity of tumors pose tremendous challenges for clinical imaging-guided PDT treatment. Herein, a polymeric nanoparticle with tumor acidity (pH e )-activatable TAT targeting ligand that encapsulates the photosensitizer chlorin e6 (Ce6) and chelates contrast agent Gd 3+ is successfully developed for fluorescence/magnetic resonance (MR) dual-model imaging-guided precision PDT. We show clear evidence that the resulting nanoparticle DA TAT-NP [its TAT lysine residues' amines was modified by 2,3-dimethylmaleic anhydride (DA)] efficiently avoids the rapid clearance by reticuloendothelial system (RES) by masking of the TAT peptide, resulting in the significantly prolonged circulation time in the blood. Once accumulating in the tumor tissues, DA TAT-NP is reactivated by tumor acidity to promote cellular uptake, resulting in enlarged fluorescence/MR imaging signal intensity and elevated in vivo PDT therapeutic effect. This concept provides new avenues to design tumor acidity-activatable targeted nanoparticles for imaging-guided cancer therapy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Evaluation of Diagnostic Systems: The Selection of Students at Risk of Academic Difficulties

    ERIC Educational Resources Information Center

    Smolkowski, Keith; Cummings, Kelli D.

    2015-01-01

    Diagnostic tools can help schools more consistently and fairly match instructional resources to the needs of their students. To ensure the best educational outcome for each child, diagnostic decision-making systems seek to balance time, clarity, and accuracy. However, recent research notes that many educational decisions tend to be made using…

  20. DNA methylation markers in combination with skeletal and dental ages to improve age estimation in children.

    PubMed

    Shi, Lei; Jiang, Fan; Ouyang, Fengxiu; Zhang, Jun; Wang, Zhimin; Shen, Xiaoming

    2018-03-01

    Age estimation is critical in forensic science, in competitive sports and games and in other age-related fields, but the current methods are suboptimal. The combination of age-associated DNA methylation markers with skeletal age (SA) and dental age (DA) may improve the accuracy and precision of age estimation, but no study has examined this topic. In the current study, we measured SA (GP, TW3-RUS, and TW3-Carpal methods) and DA (Demirjian and Willems methods) by X-ray examination in 124 Chinese children (78 boys and 46 girls) aged 6-15 years. To identify age-associated CpG sites, we analyzed methylome-wide DNA methylation profiling by using the Illumina HumanMethylation450 BeadChip system in 48 randomly selected children. Five CpG sites were identified as associated with chronologic age (CA), with an absolute value of Pearson's correlation coefficient (r)>0.5 (p<0.01) and a false discovery rate<0.01. The validation of age-associated CpG sites was performed using droplet digital PCR techniques in all 124 children. After validation, four CpG sites for boys and five CpG sites for girls were further adopted to build the age estimation model with SA and DA using multivariate linear stepwise regressions. These CpG sites were located at 4 known genes: DDO, PRPH2, DHX8, and ITGA2B and at one unknown gene with the Illumina ID number of 22398226. The accuracy of age estimation methods was compared according to the mean absolute error (MAE) and root mean square error (RMSE). The best single measure for SA was the TW3-RUS method (MAE=0.69years, RMSE=0.95years) in boys, and the GP method (MAE=0.74years, RMSE=0.94years) in girls. For DA, the Willems method was the best single measure for both boys (MAE=0.63years, RMSE=0.78years) and girls (MAE=0.54years, RMSE=0.68years). The models that incorporated SA and DA with the methylation levels of age-associated CpG sites provided the highest accuracy of age estimation in both boys (MAE=0.47years, R 2 =0.886) and girls (MAE=0.33years, R 2 =0.941). Cross validation of the results confirmed the reliability and validity of the models. In conclusion, age-associated DNA methylation markers in combination with SA and DA greatly improve the accuracy of age estimation in Chinese children. This method may be applied in forensic science, in competitive sports and games and in other age-related fields. Copyright © 2017. Published by Elsevier B.V.

  1. Dopamine fluorescent sensors based on polypyrrole/graphene quantum dots core/shell hybrids.

    PubMed

    Zhou, Xi; Ma, Peipei; Wang, Anqi; Yu, Chenfei; Qian, Tao; Wu, Shishan; Shen, Jian

    2015-02-15

    A facilely prepared fluorescent sensor was developed for dopamine (DA) detection with high sensitivity and selectivity based on polypyrrole/graphene quantum dots (PPy/GQDs) core/shell hybrids. The composites exhibit strong fluorescence emission, which is dramatically enhanced as high as three times than pristine GQDs. The prepared sensor allows a highly sensitive determination of DA by fluorescent intensity decreasing with the addition of DA and presents a good linearity in range of 5-8000 nM with the detection limit of 10 pM (S/N = 3). Furthermore, the application of the proposed approach have been demonstrated in real samples and showed promise in diagnostic purposes. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Optical coherence tomography in the diagnosis of dysplasia and adenocarcinoma in Barret's esophagus

    NASA Astrophysics Data System (ADS)

    Gladkova, N. D.; Zagaynova, E. V.; Zuccaro, G.; Kareta, M. V.; Feldchtein, F. I.; Balalaeva, I. V.; Balandina, E. B.

    2007-02-01

    Statistical analysis of endoscopic optical coherence tomography (EOCT) surveillance of 78 patients with Barrett's esophagus (BE) is presented in this study. The sensitivity of OCT device in retrospective open detection of early malignancy (including high grade dysplasia and intramucosal adenocarcinoma (IMAC)) was 75%, specificity 82%, diagnostic accuracy - 80%, positive predictive value- 60%, negative predictive value- 87%. In the open recognition of IMAC sensitivity was 81% and specificity were 85% each. Results of a blind recognition with the same material were similar: sensitivity - 77%, specificity 85%, diagnostic accuracy - 82%, positive predictive value- 70%, negative predictive value- 87%. As the endoscopic detection of early malignancy is problematic, OCT holds great promise in enhancing the diagnostic capability of clinical GI endoscopy.

  3. Influence of left ventricular hypertrophy and geometry on diagnostic accuracy of wall motion and perfusion magnetic resonance during dobutamine stress.

    PubMed

    Gebker, Rolf; Mirelis, Jesus G; Jahnke, Cosima; Hucko, Thomas; Manka, Robert; Hamdan, Ashraf; Schnackenburg, Bernhard; Fleck, Eckart; Paetsch, Ingo

    2010-09-01

    The purpose of this study was to determine the influence of left ventricular (LV) hypertrophy and geometry on the diagnostic accuracy of wall motion and additional perfusion imaging during high-dose dobutamine/atropine stress magnetic resonance for the detection of coronary artery disease. Combined dobutamine stress magnetic resonance (DSMR)-wall motion and DSMR-perfusion imaging was performed in a single session in 187 patients scheduled for invasive coronary angiography. Patients were classified into 4 categories on the basis of LV mass (normal, ≤ 81 g/m(2) in men and ≤ 62 g/m(2) in women) and relative wall thickness (RWT) (normal, <0.45) as follows: normal geometry (normal mass, normal RWT), concentric remodeling (normal mass, increased RWT), concentric hypertrophy (increased mass, increased RWT), and eccentric hypertrophy (increased mass, normal RWT). Wall motion and perfusion images were interpreted sequentially, with observers blinded to other data. Significant coronary artery disease was defined as ≥ 70% stenosis. In patients with increased LV concentricity (defined by an RWT ≥ 0.45), sensitivity and accuracy of DSMR-wall motion were significantly reduced (63% and 73%, respectively; P<0.05) compared with patients without increased LV concentricity (90% and 88%, respectively; P<0.05). Although accuracy of DSMR-perfusion was higher than that of DSMR-wall motion in patients with concentric hypertrophy (82% versus 71%; P < 0.05), accuracy of DSMR-wall motion was superior to DSMR-perfusion (90% versus 85%; P < 0.05) in patients with eccentric hypertrophy. The accuracy of DSMR-wall motion is influenced by LV geometry. In patients with concentric remodeling and concentric hypertrophy, additional first-pass perfusion imaging during high-dose dobutamine stress improves the diagnostic accuracy for the detection of coronary artery disease.

  4. Emergency department CT screening of patients with nontraumatic neurological symptoms referred to the posterior fossa: comparison of thin versus thick slice images.

    PubMed

    Kamalian, Shervin; Atkinson, Wendy L; Florin, Lauren A; Pomerantz, Stuart R; Lev, Michael H; Romero, Javier M

    2014-06-01

    Evaluation of the posterior fossa (PF) on 5-mm-thick helical CT images (current default) has improved diagnostic accuracy compared to 5-mm sequential CT images; however, 5-mm-thick images may not be ideal for PF pathology due to volume averaging of rapid changes in anatomy in the Z-direction. Therefore, we sought to determine if routine review of 1.25-mm-thin helical CT images has superior accuracy in screening for nontraumatic PF pathology. MRI proof of diagnosis was obtained within 6 h of helical CT acquisition for 90 consecutive ED patients with, and 88 without, posterior fossa lesions. Helical CT images were post-processed at 1.25 and 5-mm-axial slice thickness. Two neuroradiologists blinded to the clinical/MRI findings reviewed both image sets. Interobserver agreement and accuracy were rated using Kappa statistics and ROC analysis, respectively. Of the 90/178 (51 %) who were MR positive, 60/90 (66 %) had stroke and 30/90 (33 %) had other etiologies. There was excellent interobserver agreement (κ > 0.97) for both thick and thin slice assessments. The accuracy, sensitivity, and specificity for 1.25-mm images were 65, 44, and 84 %, respectively, and for 5-mm images were 67, 45, and 85 %, respectively. The diagnostic accuracy was not significantly different (p > 0.5). In this cohort of patients with nontraumatic neurological symptoms referred to the posterior fossa, 1.25-mm-thin slice CT reformatted images do not have superior accuracy compared to 5-mm-thick images. This information has implications on optimizing resource utilizations and efficiency in a busy emergency room. Review of 1.25-mm-thin images may help diagnostic accuracy only when review of 5-mm-thick images as current default is inconclusive.

  5. Evaluating Diagnostic Accuracy of Noninvasive Tests in Assessment of Significant Liver Fibrosis in Chronic Hepatitis C Egyptian Patients.

    PubMed

    Omran, Dalia; Zayed, Rania A; Nabeel, Mohammed M; Mobarak, Lamiaa; Zakaria, Zeinab; Farid, Azza; Hassany, Mohamed; Saif, Sameh; Mostafa, Muhammad; Saad, Omar Khalid; Yosry, Ayman

    2018-05-01

    Stage of liver fibrosis is critical for treatment decision and prediction of outcomes in chronic hepatitis C (CHC) patients. We evaluated the diagnostic accuracy of transient elastography (TE)-FibroScan and noninvasive serum markers tests in the assessment of liver fibrosis in CHC patients, in reference to liver biopsy. One-hundred treatment-naive CHC patients were subjected to liver biopsy, TE-FibroScan, and eight serum biomarkers tests; AST/ALT ratio (AAR), AST to platelet ratio index (APRI), age-platelet index (AP index), fibrosis quotient (FibroQ), fibrosis 4 index (FIB-4), cirrhosis discriminant score (CDS), King score, and Goteborg University Cirrhosis Index (GUCI). Receiver operating characteristic curves were constructed to compare the diagnostic accuracy of these noninvasive methods in predicting significant fibrosis in CHC patients. TE-FibroScan predicted significant fibrosis at cutoff value 8.5 kPa with area under the receiver operating characteristic (AUROC) 0.90, sensitivity 83%, specificity 91.5%, positive predictive value (PPV) 91.2%, and negative predictive value (NPV) 84.4%. Serum biomarkers tests showed that AP index and FibroQ had the highest diagnostic accuracy in predicting significant liver fibrosis at cutoff 4.5 and 2.7, AUROC was 0.8 and 0.8 with sensitivity 73.6% and 73.6%, specificity 70.2% and 68.1%, PPV 71.1% and 69.8%, and NPV 72.9% and 72.3%, respectively. Combined AP index and FibroQ had AUROC 0.83 with sensitivity 73.6%, specificity 80.9%, PPV 79.6%, and NPV 75.7% for predicting significant liver fibrosis. APRI, FIB-4, CDS, King score, and GUCI had intermediate accuracy in predicting significant liver fibrosis with AUROC 0.68, 0.78, 0.74, 0.74, and 0.67, respectively, while AAR had low accuracy in predicting significant liver fibrosis. TE-FibroScan is the most accurate noninvasive alternative to liver biopsy. AP index and FibroQ, either as individual tests or combined, have good accuracy in predicting significant liver fibrosis, and are better combined for higher specificity.

  6. The diagnostic value of polymerase chain reaction for Mycobacterium tuberculosis to distinguish intestinal tuberculosis from crohn's disease: A meta-analysis.

    PubMed

    Jin, Ting; Fei, Baoying; Zhang, Yu; He, Xujun

    2017-01-01

    Intestinal tuberculosis (ITB) and Crohn's disease (CD) are important differential diagnoses that can be difficult to distinguish. Polymerase chain reaction (PCR) for Mycobacterium tuberculosis (MTB) is an efficient and promising tool. This meta-analysis was performed to systematically and objectively assess the potential diagnostic accuracy and clinical value of PCR for MTB in distinguishing ITB from CD. We searched PubMed, Embase, Web of Science, Science Direct, and the Cochrane Library for eligible studies, and nine articles with 12 groups of data were identified. The included studies were subjected to quality assessment using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The summary estimates were as follows: sensitivity 0.47 (95% CI: 0.42-0.51); specificity 0.95 (95% CI: 0.93-0.97); the positive likelihood ratio (PLR) 10.68 (95% CI: 6.98-16.35); the negative likelihood ratio (NLR) 0.49 (95% CI: 0.33-0.71); and diagnostic odds ratio (DOR) 21.92 (95% CI: 13.17-36.48). The area under the curve (AUC) was 0.9311, with a Q* value of 0.8664. Heterogeneity was found in the NLR. The heterogeneity of the studies was evaluated by meta-regression analysis and subgroup analysis. The current evidence suggests that PCR for MTB is a promising and highly specific diagnostic method to distinguish ITB from CD. However, physicians should also keep in mind that negative results cannot exclude ITB for its low sensitivity. Additional prospective studies are needed to further evaluate the diagnostic accuracy of PCR.

  7. Diagnostic accuracy of clinical tests of the hip: a systematic review with meta-analysis.

    PubMed

    Reiman, Michael P; Goode, Adam P; Hegedus, Eric J; Cook, Chad E; Wright, Alexis A

    2013-09-01

    Hip Physical Examination (HPE) tests have long been used to diagnose a myriad of intra-and extra-articular pathologies of the hip joint. Useful clinical utility is necessary to support diagnostic imaging and subsequent surgical decision making. Summarise and evaluate the current research and utility on the diagnostic accuracy of HPE tests for the hip joint germane to sports related injuries and pathology. A computer-assisted literature search of MEDLINE, CINHAL and EMBASE databases (January 1966 to January 2012) using keywords related to diagnostic accuracy of the hip joint. This systematic review with meta-analysis utilised the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for the search and reporting phases of the study. Der-Simonian and Laird random effects models were used to summarise sensitivities (SN), specificities (SP), likelihood ratios and diagnostic OR. The employed search strategy revealed 25 potential articles, with 10 demonstrating high quality. Fourteen articles qualified for meta-analysis. The meta-analysis demonstrated that most tests possess weak diagnostic properties with the exception of the patellar-pubic percussion test, which had excellent pooled SN 95 (95% CI 92 to 97%) and good specificity 86 (95% CI 78 to 92%). Several studies have investigated pathology in the hip. Few of the current studies are of substantial quality to dictate clinical decision-making. Currently, only the patellar-pubic percussion test is supported by the data as a stand-alone HPE test. Further studies involving high quality designs are needed to fully assess the value of HPE tests for patients with intra- and extra-articular hip dysfunction.

  8. The role of strategy and redundancy in diagnostic reasoning.

    PubMed

    Bloch, Ralph F; Hofer, Daniel; Feller, Sabine; Hodel, Maria

    2003-01-24

    Diagnostic reasoning is a key competence of physicians. We explored the effects of knowledge, practice and additional clinical information on strategy, redundancy and accuracy of diagnosing a peripheral neurological defect in the hand based on sensory examination. Using an interactive computer simulation that includes 21 unique cases with seven sensory loss patterns and either concordant, neutral or discordant textual information, 21 3rd year medical students, 21 6th year and 21 senior neurology residents each examined 15 cases over the course of one session. An additional 23 psychology students examined 24 cases over two sessions, 12 cases per session. Subjects also took a seven-item MCQ exam of seven classical patterns presented visually. Knowledge of sensory patterns and diagnostic accuracy are highly correlated within groups (R2 = 0.64). The total amount of information gathered for incorrect diagnoses is no lower than that for correct diagnoses. Residents require significantly fewer tests than either psychology or 6th year students, who in turn require fewer than the 3rd year students (p < 0.001). The diagnostic accuracy of subjects is affected both by level of training (p < 0.001) and concordance of clinical information (p < 0.001). For discordant cases, refutation testing occurs significantly in 6th year students (p < 0.001) and residents (p < 0.01), but not in psychology or 3rd year students. Conversely, there is a stable 55% excess of confirmatory testing, independent of training or concordance. Knowledge and practice are both important for diagnostic success. For complex diagnostic situations reasoning components employing redundancy seem more essential than those using strategy.

  9. Chemogenetic Activation of Midbrain Dopamine Neurons Affects Attention, but not Impulsivity, in the Five-Choice Serial Reaction Time Task in Rats.

    PubMed

    Boekhoudt, Linde; Voets, Elisa S; Flores-Dourojeanni, Jacques P; Luijendijk, Mieneke Cm; Vanderschuren, Louk Jmj; Adan, Roger Ah

    2017-05-01

    Attentional impairments and exaggerated impulsivity are key features of psychiatric disorders, such as attention-deficit/hyperactivity disorder, schizophrenia, and addiction. These deficits in attentional performance and impulsive behaviors have been associated with aberrant dopamine (DA) signaling, but it remains unknown whether these deficits result from enhanced DA neuronal activity in the midbrain. Here, we took a novel approach by testing the impact of chemogenetically activating DA neurons in the ventral tegmental area (VTA) or substantia nigra pars compacta (SNc) on attention and impulsivity in the five-choice serial reaction time task (5-CSRTT) in rats. We found that activation of DA neurons in both the VTA and SNc impaired attention by increasing trial omissions. In addition, SNc DA neuron activation decreased attentional accuracy. Surprisingly, enhanced DA neuron activity did not affect impulsive action in this task. These results show that enhanced midbrain DA neuronal activity induces deficits in attentional performance, but not impulsivity. Furthermore, DA neurons in the VTA and SNc have different roles in regulating attention. These findings contribute to our understanding of the neural substrates underlying attention deficits and impulsivity, and provide valuable insights to improve treatment of these symptoms.

  10. The aqueous phase of Alzheimer's disease brain contains assemblies built from ∼4 and ∼7 kDa Aβ species.

    PubMed

    Mc Donald, Jessica M; O'Malley, Tiernan T; Liu, Wen; Mably, Alexandra J; Brinkmalm, Gunnar; Portelius, Erik; Wittbold, William M; Frosch, Matthew P; Walsh, Dominic M

    2015-11-01

    Much knowledge about amyloid β (Aβ) aggregation and toxicity has been acquired using synthetic peptides and mouse models, whereas less is known about soluble Aβ in human brain. We analyzed aqueous extracts from multiple AD brains using an array of techniques. Brains can contain at least four different Aβ assembly forms including: (i) monomers, (ii) a ∼7 kDa Aβ species, and larger species (iii) from ∼30-150 kDa, and (iv) >160 kDa. High molecular weight species are by far the most prevalent and appear to be built from ∼7 kDa Aβ species. The ∼7 kDa Aβ species resist denaturation by chaotropic agents and have a higher Aβ42/Aβ40 ratio than monomers, and are unreactive with antibodies to Asp1 of Ab or APP residues N-terminal of Asp1. Further analysis of brain-derived ∼7 kDa Aβ species, the mechanism by which they assemble and the structures they form should reveal therapeutic and diagnostic opportunities. Copyright © 2015 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  11. Preparation of chitosan grafted graphite composite for sensitive detection of dopamine in biological samples.

    PubMed

    Palanisamy, Selvakumar; Thangavelu, Kokulnathan; Chen, Shen-Ming; Gnanaprakasam, P; Velusamy, Vijayalakshmi; Liu, Xiao-Heng

    2016-10-20

    The accurate detection of dopamine (DA) levels in biological samples such as human serum and urine are essential indicators in medical diagnostics. In this work, we describe the preparation of chitosan (CS) biopolymer grafted graphite (GR) composite for the sensitive and lower potential detection of DA in its sub micromolar levels. The composite modified electrode has been used for the detection of DA in biological samples such as human serum and urine. The GR-CS composite modified electrode shows an enhanced oxidation peak current response and low oxidation potential for the detection of DA than that of electrodes modified with bare, GR and CS discretely. Under optimum conditions, the fabricated GR-CS composite modified electrode shows the DPV response of DA in the linear response ranging from 0.03 to 20.06μM. The detection limit and sensitivity of the sensor were estimated as 0.0045μM and 6.06μA μM(-1)cm(-2), respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Brain on Fire: Incentive Salience, Hedonic Hot Spots, Dopamine, Obesity, and Other Hunger Games.

    PubMed

    Cameron, Jameason D; Chaput, Jean-Philippe; Sjödin, Anders M; Goldfield, Gary S

    2017-08-21

    This review examines human feeding behavior in light of psychological motivational theory and highlights the importance of midbrain dopamine (DA). Prospective evidence of both reward surfeit and reward deficit pathways to increased body weight are evaluated, and we argue that it is more complex than an either/or scenario when examining DA's role in reward sensitivity, eating, and obesity. The Taq1A genotype is a common thread that ties the contrasting models of DA reward and obesity; this genotype related to striatal DA is not associated with obesity class per se but may nevertheless confer an increased risk of weight gain. We also critically examine the concept of so-called food addiction, and despite growing evidence, we argue that there is currently insufficient human data to warrant this diagnostic label. The surgical and pharmacological treatments of obesity are discussed, and evidence is presented for the selective use of DA-class drugs in obesity treatment.

  13. Staging of colorectal liver metastases after preoperative chemotherapy. Diffusion-weighted imaging in combination with Gd-EOB-DTPA MRI sequences increases sensitivity and diagnostic accuracy.

    PubMed

    Macera, Annalisa; Lario, Chiara; Petracchini, Massimo; Gallo, Teresa; Regge, Daniele; Floriani, Irene; Ribero, Dario; Capussotti, Lorenzo; Cirillo, Stefano

    2013-03-01

    To compare the diagnostic accuracy and sensitivity of Gd-EOB-DTPA MRI and diffusion-weighted (DWI) imaging alone and in combination for detecting colorectal liver metastases in patients who had undergone preoperative chemotherapy. Thirty-two consecutive patients with a total of 166 liver lesions were retrospectively enrolled. Of the lesions, 144 (86.8 %) were metastatic at pathology. Three image sets (1, Gd-EOB-DTPA; 2, DWI; 3, combined Gd-EOB-DTPA and DWI) were independently reviewed by two observers. Statistical analysis was performed on a per-lesion basis. Evaluation of image set 1 correctly identified 127/166 lesions (accuracy 76.5 %; 95 % CI 69.3-82.7) and 106/144 metastases (sensitivity 73.6 %, 95 % CI 65.6-80.6). Evaluation of image set 2 correctly identified 108/166 (accuracy 65.1 %, 95 % CI 57.3-72.3) and 87/144 metastases (sensitivity of 60.4 %, 95 % CI 51.9-68.5). Evaluation of image set 3 correctly identified 148/166 (accuracy 89.2 %, 95 % CI 83.4-93.4) and 131/144 metastases (sensitivity 91 %, 95 % CI 85.1-95.1). Differences were statistically significant (P < 0.001). Notably, similar results were obtained analysing only small lesions (<1 cm). The combination of DWI with Gd-EOB-DTPA-enhanced MRI imaging significantly increases the diagnostic accuracy and sensitivity in patients with colorectal liver metastases treated with preoperative chemotherapy, and it is particularly effective in the detection of small lesions.

  14. The Value of Physical Examination: A New Conceptual Framework.

    PubMed

    Zaman, Junaid; Verghese, Abraham; Elder, Andrew

    2016-12-01

    The physical examination defines medical practice, yet its role is being questioned increasingly, with statistical comparisons of diagnostic accuracy often the sole metric used against newer technologies. We set out to highlight seven ways in which the physical examination has value beyond diagnostic accuracy to reaffirm its place in the core skills of a physician and guide future research, teaching, and curriculum design. We show that this more comprehensive approach to the physical examination of its "utility" beyond that of reaching a diagnosis can be beneficial to both doctor and patient.

  15. Rolling bearing fault diagnosis based on information fusion using Dempster-Shafer evidence theory

    NASA Astrophysics Data System (ADS)

    Pei, Di; Yue, Jianhai; Jiao, Jing

    2017-10-01

    This paper presents a fault diagnosis method for rolling bearing based on information fusion. Acceleration sensors are arranged at different position to get bearing vibration data as diagnostic evidence. The Dempster-Shafer (D-S) evidence theory is used to fuse multi-sensor data to improve diagnostic accuracy. The efficiency of the proposed method is demonstrated by the high speed train transmission test bench. The results of experiment show that the proposed method in this paper improves the rolling bearing fault diagnosis accuracy compared with traditional signal analysis methods.

  16. Hounsfield Unit inaccuracy in computed tomography lesion size and density, diagnostic quality vs attenuation correction

    NASA Astrophysics Data System (ADS)

    Szczepura, Katy; Thompson, John; Manning, David

    2017-03-01

    In computed tomography the Hounsfield Units (HU) are used as an indicator of the tissue type based on the linear attenuation coefficients of the tissue. HU accuracy is essential when this metric is used in any form to support diagnosis. In hybrid imaging, such as SPECT/CT and PET/CT, the information is used for attenuation correction (AC) of the emission images. This work investigates the HU accuracy of nodules of known size and HU, comparing diagnostic quality (DQ) images with images used for AC.

  17. Accuracy of clinical neurological examination in diagnosing lumbo-sacral radiculopathy: a systematic literature review.

    PubMed

    Tawa, Nassib; Rhoda, Anthea; Diener, Ina

    2017-02-23

    Lumbar radiculopathy remains a clinical challenge among primary care clinicians in both assessment and diagnosis. This often leads to misdiagnosis and inappropriate treatment of patients resulting in poor health outcomes, exacerbating this already debilitating condition. This review evaluated 12 primary diagnostic accuracy studies that specifically assessed the performance of various individual and grouped clinical neurological tests in detecting nerve root impingement, as established in the current literature. Eight electronic data bases were searched for relevant articles from inception until July 2016. All primary diagnostic studies which investigated the accuracy of clinical neurological test (s) in diagnosing lumbar radiculopathy among patients with low back and referred leg symptoms were screened for inclusion. Qualifying studies were retrieved and independently assessed for methodological quality using the 'Quality Assessment of Diagnostic tests Accuracy Studies' criteria. A total of 12 studies which investigated standard components of clinical neurological examination of (sensory, motor, tendon reflex and neuro-dynamics) of the lumbo-sacral spine were included. The mean inter-observer agreement on quality assessment by two independent reviewers was fair (k = 0.3 - 0.7). The diagnostic performance of sensory testing using MR imaging as a reference standard demonstrated a sensitivity (confidence interval 95%) 0.61 (0.47-0.73) and a specificity of 0.63 (0.38-0.84). Motor tests sensitivity was poor to moderate, ranging from 0.13 (0.04-0.31) to 0.61 (0.36-0.83). Generally, the diagnostic performance of reflex testing was notably good with specificity ranging from (confidence interval 95%) 0.60 (0.51-0.69) to 0.93 (0.87-0.97) and sensitivity ranging from 0.14 (0.09-0.21) to 0.67 (0.21-0.94). Femoral nerve stretch test had a high sensitivity of (confidence interval 95%) 1.00 (0.40-1.00) and specificity of 0.83 (0.52-0.98) while SLR test recorded a mean sensitivity of 0.84 (0.72-0.92) and specificity of 0.78 (0.67-0.87). There is a scarcity of studies on the diagnostic accuracy of clinical neurological examination testing. Furthermore there seem to be a disconnect among researchers regarding the diagnostic utility of lower limb neuro-dynamic tests which include the Straight Leg Raise and Femoral Nerve tests for sciatic and femoral nerve respectively. Whether these tests are able to detect the presence of disc herniation and subsequent nerve root compression or hyper-sensitivity of the sacral and femoral plexus due to mechanical irritation still remains debatable.

  18. Driving performance in persons with mild to moderate symptoms of multiple sclerosis.

    PubMed

    Devos, Hannes; Brijs, Tom; Alders, Geert; Wets, Geert; Feys, Peter

    2013-08-01

    To investigate whether driving performance is impaired in persons with mild to moderate multiple sclerosis (MS). This study included 15 persons with MS (pwMS) and 17 healthy controls. The MS group exhibited mild to moderate impairments on the Expanded Disability Status Scale (median, Q1-Q3; 3.5, 2.5-4). The driving simulation required participants to drive in daily traffic while attending to a divided attention (DA) task. Computerized measures on the driving task included number of accidents, tickets, speed maintenance, standard deviation of lateral position, and time to collision. Response times and accuracy on the DA task were also computer generated. Additionally, pwMS completed a clinical evaluation encompassing motor, functional, visual, psychosocial and cognitive tests. No differences between healthy controls and pwMS were observed on all measures of the primary driving task. PwMS performed worse than healthy controls on DA response time (3.10 s, 2.87-3.68 versus 2.15 s, 2.04-2.43; p = 0.001) and accuracy (15 correct answers, 11-18 versus 24 correct answers, 22-25; p < 0.0001). Depression was significantly associated with time to collision (r = -0.77; p < 0.01). Subjects with mild to moderate MS are able to prioritize the driving task above the DA task. The relationship between depression and driving performance in MS merits further investigation.

  19. Photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot

    NASA Astrophysics Data System (ADS)

    Gandhi, Neeraj; Allard, Margaret; Kim, Sungmin; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2017-12-01

    Death and paralysis are significant risks of modern surgeries, caused by injury to blood vessels and nerves hidden by bone and other tissue. We propose an approach to surgical guidance that relies on photoacoustic (PA) imaging to determine the separation between these critical anatomical features and to assess the extent of safety zones during surgical procedures. Images were acquired as an optical fiber was swept across vessel-mimicking targets, in the absence and presence of teleoperation with a research da Vinci Surgical System. Vessel separation distances were measured directly from PA images. Vessel positions were additionally recorded based on the fiber position (calculated from the da Vinci robot kinematics) that corresponded to an observed PA signal, and these recordings were used to indirectly measure vessel separation distances. Amplitude- and coherence-based beamforming were used to estimate vessel separations, resulting in 0.52- to 0.56-mm mean absolute errors, 0.66- to 0.71-mm root-mean-square errors, and 65% to 68% more accuracy compared to fiber position measurements obtained through the da Vinci robot kinematics. Similar accuracy was achieved in the presence of up to 4.5-mm-thick ex vivo tissue. Results indicate that PA image-based measurements of the separation among anatomical landmarks could be a viable method for real-time path planning in multiple interventional PA applications.

  20. The multiple hop test: a discriminative or evaluative instrument for chronic ankle instability?

    PubMed

    Eechaute, Christophe; Bautmans, Ivan; De Hertogh, Willem; Vaes, Peter

    2012-05-01

    To determine whether the multiple hop test should be used as an evaluative or a discriminative instrument for chronic ankle instability (CAI). Blinded case-control study. : University research laboratory. Twenty-nine healthy subjects (21 men, 8 women, mean age 21.8 years) and 29 patients with CAI (17 men, 12 women, mean age 24.9 years) were selected. Subjects performed a multiple hop test and hopped on 10 different tape markers while trying to avoid any postural correction. Minimal detectable changes (MDC) of the number of balance errors, the time value, and the visual analog scale (VAS) score (perceived difficulty) were calculated as evaluative measures. For the discriminative properties, a receiver operating characteristic curve was determined and the area under curve (AUC), the sensitivity, specificity, diagnostic accuracy (DA), and likelihood ratios (LR) were calculated whether 1, 2, or 3 outcomes were positive. Based on their MDC, outcomes should, respectively, change by more than 7 errors (41%), 6 seconds (15%), and 27 mm (55%, VAS score) before considering it as a real change. Area under curves were, respectively, 79% (errors), 77% (time value), and 65% (VAS score). The most optimal cutoff point was, respectively, 13.5 errors, 35 seconds, and 32.5 mm. When 2 of 3 outcomes were positive, the sensitivity was 86%, the specificity was 79%, the DA was 83%, the positive LR was 4.2, and the negative LR was 0.17. The multiple hop test seems to be more a discriminative instrument for CAI, and its responsiveness needs to be demonstrated.

  1. Can color-coded parametric maps improve dynamic enhancement pattern analysis in MR mammography?

    PubMed

    Baltzer, P A; Dietzel, M; Vag, T; Beger, S; Freiberg, C; Herzog, A B; Gajda, M; Camara, O; Kaiser, W A

    2010-03-01

    Post-contrast enhancement characteristics (PEC) are a major criterion for differential diagnosis in MR mammography (MRM). Manual placement of regions of interest (ROIs) to obtain time/signal intensity curves (TSIC) is the standard approach to assess dynamic enhancement data. Computers can automatically calculate the TSIC in every lesion voxel and combine this data to form one color-coded parametric map (CCPM). Thus, the TSIC of the whole lesion can be assessed. This investigation was conducted to compare the diagnostic accuracy (DA) of CCPM with TSIC for the assessment of PEC. 329 consecutive patients with 469 histologically verified lesions were examined. MRM was performed according to a standard protocol (1.5 T, 0.1 mmol/kgbw Gd-DTPA). ROIs were drawn manually within any lesion to calculate the TSIC. CCPMs were created in all patients using dedicated software (CAD Sciences). Both methods were rated by 2 observers in consensus on an ordinal scale. Receiver operating characteristics (ROC) analysis was used to compare both methods. The area under the curve (AUC) was significantly (p=0.026) higher for CCPM (0.829) than TSIC (0.749). The sensitivity was 88.5% (CCPM) vs. 82.8% (TSIC), whereas equal specificity levels were found (CCPM: 63.7%, TSIC: 63.0%). The color-coded parametric maps (CCPMs) showed a significantly higher DA compared to TSIC, in particular the sensitivity could be increased. Therefore, the CCPM method is a feasible approach to assessing dynamic data in MRM and condenses several imaging series into one parametric map. © Georg Thieme Verlag KG Stuttgart · New York.

  2. A feature-preserving hair removal algorithm for dermoscopy images.

    PubMed

    Abbas, Qaisar; Garcia, Irene Fondón; Emre Celebi, M; Ahmad, Waqar

    2013-02-01

    Accurate segmentation and repair of hair-occluded information from dermoscopy images are challenging tasks for computer-aided detection (CAD) of melanoma. Currently, many hair-restoration algorithms have been developed, but most of these fail to identify hairs accurately and their removal technique is slow and disturbs the lesion's pattern. In this article, a novel hair-restoration algorithm is presented, which has a capability to preserve the skin lesion features such as color and texture and able to segment both dark and light hairs. Our algorithm is based on three major steps: the rough hairs are segmented using a matched filtering with first derivative of gaussian (MF-FDOG) with thresholding that generate strong responses for both dark and light hairs, refinement of hairs by morphological edge-based techniques, which are repaired through a fast marching inpainting method. Diagnostic accuracy (DA) and texture-quality measure (TQM) metrics are utilized based on dermatologist-drawn manual hair masks that were used as a ground truth to evaluate the performance of the system. The hair-restoration algorithm is tested on 100 dermoscopy images. The comparisons have been done among (i) linear interpolation, inpainting by (ii) non-linear partial differential equation (PDE), and (iii) exemplar-based repairing techniques. Among different hair detection and removal techniques, our proposed algorithm obtained the highest value of DA: 93.3% and TQM: 90%. The experimental results indicate that the proposed algorithm is highly accurate, robust and able to restore hair pixels without damaging the lesion texture. This method is fully automatic and can be easily integrated into a CAD system. © 2011 John Wiley & Sons A/S.

  3. Diagnostic accuracy of atypical p-ANCA in autoimmune hepatitis using ROC- and multivariate regression analysis.

    PubMed

    Terjung, B; Bogsch, F; Klein, R; Söhne, J; Reichel, C; Wasmuth, J-C; Beuers, U; Sauerbruch, T; Spengler, U

    2004-09-29

    Antineutrophil cytoplasmic antibodies (atypical p-ANCA) are detected at high prevalence in sera from patients with autoimmune hepatitis (AIH), but their diagnostic relevance for AIH has not been systematically evaluated so far. Here, we studied sera from 357 patients with autoimmune (autoimmune hepatitis n=175, primary sclerosing cholangitis (PSC) n=35, primary biliary cirrhosis n=45), non-autoimmune chronic liver disease (alcoholic liver cirrhosis n=62; chronic hepatitis C virus infection (HCV) n=21) or healthy controls (n=19) for the presence of various non-organ specific autoantibodies. Atypical p-ANCA, antinuclear antibodies (ANA), antibodies against smooth muscles (SMA), antibodies against liver/kidney microsomes (anti-Lkm1) and antimitochondrial antibodies (AMA) were detected by indirect immunofluorescence microscopy, antibodies against the M2 antigen (anti-M2), antibodies against soluble liver antigen (anti-SLA/LP) and anti-Lkm1 by using enzyme linked immunosorbent assays. To define the diagnostic precision of the autoantibodies, results of autoantibody testing were analyzed by receiver operating characteristics (ROC) and forward conditional logistic regression analysis. Atypical p-ANCA were detected at high prevalence in sera from patients with AIH (81%) and PSC (94%). ROC- and logistic regression analysis revealed atypical p-ANCA and SMA, but not ANA as significant diagnostic seromarkers for AIH (atypical p-ANCA: AUC 0.754+/-0.026, odds ratio [OR] 3.4; SMA: 0.652+/-0.028, OR 4.1). Atypical p-ANCA also emerged as the only diagnostically relevant seromarker for PSC (AUC 0.690+/-0.04, OR 3.4). None of the tested antibodies yielded a significant diagnostic accuracy for patients with alcoholic liver cirrhosis, HCV or healthy controls. Atypical p-ANCA along with SMA represent a seromarker with high diagnostic accuracy for AIH and should be explicitly considered in a revised version of the diagnostic score for AIH.

  4. Identifying language impairment in bilingual children in France and in Germany.

    PubMed

    Tuller, Laurice; Hamann, Cornelia; Chilla, Solveig; Ferré, Sandrine; Morin, Eléonore; Prevost, Philippe; Dos Santos, Christophe; Abed Ibrahim, Lina; Zebib, Racha

    2018-05-23

    The detection of specific language impairment (SLI) in children growing up bilingually presents particular challenges for clinicians. Non-word repetition (NWR) and sentence repetition (SR) tasks have proven to be the most accurate diagnostic tools for monolingual populations, raising the question of the extent of their usefulness in different bilingual populations. To determine the diagnostic accuracy of NWR and SR tasks that incorporate phonological/syntactic complexity as discussed in recent linguistic theory. The tasks were developed as part of the Language Impairment Testing in Multilingual Settings (LITMUS) toolkit, in two different national settings, France and Germany, and investigated children with three different home languages: Arabic, Portuguese and Turkish. NWR and SR tasks developed in parallel were administered to 151 bilingual children, aged 5;6-8;11, in France and in Germany, to 64 children in speech-language therapy (SLT) and to 87 children not in SLT, whose first language (L1) was Arabic, Portuguese or Turkish. Children were also administered standardized language tests in each of their languages to determine likely clinical status (typical development (TD) or SLI), and parents responded to a questionnaire including questions about early and current language use (bilingualism factors) and early language development (risk factors for SLI). Monolingual controls included 47 TD children and 29 children with SLI. Results were subjected to inter-group comparisons, to diagnostic accuracy calculation, and to correlation and multiple regression analyses. In accordance with previous studies, NWR and SR identified SLI in the monolingual children, yielding good to excellent diagnostic accuracy. Diagnostic accuracy in bilingual children was fair to good, generally distinguishing children likely to have SLI from children likely to have TD. Accuracy was necessarily linked to the determination of clinical status, which was based on standardized assessment in each of the child's languages. Positive early development, a composite risk factor for SLI, and not variables related to language exposure and use, generally emerged as the strongest predictor of performance on the two tasks, constituting additional, independent support for the efficacy of NWR and SR in identifying impairment in bilingual children. NWR and SR tasks informed by linguistic theory are appropriate for use as part of the diagnostic process for identifying language impairment in bilingual children for whom the language of assessment is different from the home language, in diverse sociolinguistic contexts. © 2018 Royal College of Speech and Language Therapists.

  5. Dehydrin expression as a potential diagnostic tool for cold stress in white clover.

    PubMed

    Vaseva, Irina Ivanova; Anders, Iwona; Yuperlieva-Mateeva, Bistra; Nenkova, Rosa; Kostadinova, Anelia; Feller, Urs

    2014-05-01

    Cold acclimation is important for crop survival in environments undergoing seasonal low temperatures. It involves the induction of defensive mechanisms including the accumulation of different cryoprotective molecules among which are dehydrins (DHN). Recently several sequences coding for dehydrins were identified in white clover (Trifolium repens). This work aimed to select the most responsive to cold stress DHN analogues in search for cold stress diagnostic markers. The assessment of dehydrin transcript accumulation via RT-PCR and immunodetection performed with three antibodies against the conserved K-, Y-, and S-segment allowed to outline different dehydrin types presented in the tested samples. Both analyses confirmed that YnKn dehydrins were underrepresented in the controls but exposure to low temperature specifically induced their accumulation. Strong immunosignals corresponding to 37-40 kDa with antibodies against Y- and K-segment were revealed in cold-stressed leaves. Another 'cold-specific' band at position 52-55 kDa was documented on membranes probed with antibodies against K-segment. Real time RT-qPCR confirmed that low temperatures induced the accumulation of SKn and YnSKn transcripts in leaves and reduced their expression in roots. Results suggest that a YnKn dehydrin transcript with GenBank ID: KC247805 and the immunosignal at 37-40 kDa, obtained with antibodies against Y- and K-segment are reliable markers for cold stress in white clover. The assessment of SKn (GenBank ID: EU846208) and YnSKn (GenBank ID: KC247804) transcript levels in leaves could serve as additional diagnostic tools. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  6. Contrast-enhanced small-animal PET/CT in cancer research: strong improvement of diagnostic accuracy without significant alteration of quantitative accuracy and NEMA NU 4-2008 image quality parameters.

    PubMed

    Lasnon, Charline; Quak, Elske; Briand, Mélanie; Gu, Zheng; Louis, Marie-Hélène; Aide, Nicolas

    2013-01-17

    The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images. This study evaluated the diagnostic performance and accuracy of quantitative values in contrast-enhanced small-animal PET/CT (CEPET/CT) as compared to unenhanced small animal PET/CT (UEPET/CT). Firstly, a NEMA NU 4-2008 phantom (filled with 18F-FDG or 18F-FDG plus contrast media) and a homemade phantom, mimicking an abdominal tumor surrounded by water or contrast media, were used to evaluate the impact of iodinated contrast media on the image quality parameters and accuracy of quantitative values for a pertinent-sized target. Secondly, two studies in 22 abdominal tumor-bearing mice and rats were performed. The first animal experiment studied the impact of a dual-contrast media protocol, comprising the intravenous injection of a long-lasting contrast agent mixed with 18F-FDG and the intraperitoneal injection of contrast media, on tumor delineation and the accuracy of quantitative values. The second animal experiment compared the diagnostic performance and quantitative values of CEPET/CT versus UEPET/CT by sacrificing the animals after the tracer uptake period and imaging them before and after intraperitoneal injection of contrast media. There was minimal impact on IQ parameters (%SDunif and spillover ratios in air and water) when the NEMA NU 4-2008 phantom was filled with 18F-FDG plus contrast media. In the homemade phantom, measured activity was similar to true activity (-0.02%) and overestimated by 10.30% when vials were surrounded by water or by an iodine solution, respectively. The first animal experiment showed excellent tumor delineation and a good correlation between small-animal (SA)-PET and ex vivo quantification (r2 = 0.87, P < 0.0001). The second animal experiment showed a good correlation between CEPET/CT and UEPET/CT quantitative values (r2 = 0.99, P < 0.0001). Receiver operating characteristic analysis demonstrated better diagnostic accuracy of CEPET/CT versus UEPET/CT (senior researcher, area under the curve (AUC) 0.96 versus 0.77, P = 0.004; junior researcher, AUC 0.78 versus 0.58, P = 0.004). The use of iodinated contrast media for small-animal PET imaging significantly improves tumor delineation and diagnostic performance, without significant alteration of SA-PET quantitative accuracy and NEMA NU 4-2008 IQ parameters.

  7. Simultaneous fingerprint and high-wavenumber fiber-optic Raman spectroscopy improves in vivo diagnosis of esophageal squamous cell carcinoma at endoscopy

    NASA Astrophysics Data System (ADS)

    Wang, Jianfeng; Lin, Kan; Zheng, Wei; Yu Ho, Khek; Teh, Ming; Guan Yeoh, Khay; Huang, Zhiwei

    2015-08-01

    This work aims to evaluate clinical value of a fiber-optic Raman spectroscopy technique developed for in vivo diagnosis of esophageal squamous cell carcinoma (ESCC) during clinical endoscopy. We have developed a rapid fiber-optic Raman endoscopic system capable of simultaneously acquiring both fingerprint (FP)(800-1800 cm-1) and high-wavenumber (HW)(2800-3600 cm-1) Raman spectra from esophageal tissue in vivo. A total of 1172 in vivo FP/HW Raman spectra were acquired from 48 esophageal patients undergoing endoscopic examination. The total Raman dataset was split into two parts: 80% for training; while 20% for testing. Partial least squares-discriminant analysis (PLS-DA) and leave-one patient-out, cross validation (LOPCV) were implemented on training dataset to develop diagnostic algorithms for tissue classification. PLS-DA-LOPCV shows that simultaneous FP/HW Raman spectroscopy on training dataset provides a diagnostic sensitivity of 97.0% and specificity of 97.4% for ESCC classification. Further, the diagnostic algorithm applied to the independent testing dataset based on simultaneous FP/HW Raman technique gives a predictive diagnostic sensitivity of 92.7% and specificity of 93.6% for ESCC identification, which is superior to either FP or HW Raman technique alone. This work demonstrates that the simultaneous FP/HW fiber-optic Raman spectroscopy technique improves real-time in vivo diagnosis of esophageal neoplasia at endoscopy.

  8. Comparison of fine-needle aspiration and core needle biopsy under ultrasonographic guidance for detecting malignancy and for the tissue-specific diagnosis of salivary gland tumors.

    PubMed

    Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H

    2015-06-01

    Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no difference between the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy according to the internal composition of the lesions. There were no complications requiring intervention or hospitalization in our patients. Ultrasonography-guided core needle biopsy is superior to ultrasonography-guided fine-needle aspiration in detecting and characterizing malignant tumors of the salivary gland and could emerge as the diagnostic method of choice for patients presenting with a salivary gland mass. © 2015 by American Journal of Neuroradiology.

  9. Macular Ganglion Cell Imaging Study: Covariate Effects on the Spectral Domain Optical Coherence Tomography for Glaucoma Diagnosis.

    PubMed

    Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook

    2016-01-01

    To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size.

  10. Measurement Issues: Screening and diagnostic instruments for autism spectrum disorders – lessons from research and practice

    PubMed Central

    Charman, Tony; Gotham, Katherine

    2012-01-01

    Background and Scope Significant progress has been made over the past two decades in the development of screening and diagnostic instruments for autism spectrum disorders (ASD). This article reviews this progress, including recent innovations, focussing on those instruments for which the strongest research data on validity exists, and then turns to addressing issues arising from their use in clinical settings. Findings Research studies have evaluated the ability of screens to prospectively identify cases of ASD in population-based and clinically-referred samples, as well as the accuracy of diagnostic instruments to map onto ‘gold standard’ clinical best estimate diagnosis. However, extension of the findings to clinical services must be done with caution, with a full understanding that instrument properties are sample-specific. Furthermore, we are limited by the lack of a true test for ASD, which remains a behaviourally-defined disorder. In addition screening and diagnostic instruments help clinicians least in the cases where they are most in want of direction, since their accuracy will always be lower for marginal cases. Conclusion Instruments help clinicians to collect detailed, structured information and increase accuracy and reliability of referral for in-depth assessment and recommendations for support, but further research is needed to refine their effective use in clinical settings. PMID:23539140

  11. FNA diagnostic value in patients with neck masses in two teaching hospitals in Iran.

    PubMed

    Saatian, Minoo; Badie, Banafsheh Moradmand; Shahriari, Sogol; Fattahi, Fahimeh; Rasoolinejad, Mehrnaz

    2011-01-01

    The FNA (fine needle aspiration) procedure is simple, inexpensive, available and a safe method for the diagnosis of a neck mass. FNA has numerous advantages over open surgical biopsies as an initial diagnostic tool; therefore we decided to compare the accuracy of this method with open biopsy. This retrospective as well as descriptive study comparing preoperative FNA results with existing data in the Pathology Department in Bu-Ali and Amir Alam Hospitals. Our study included 100 patients with neck masses of which 22 were thyroid masses, 31 were salivary gland masses, and 47 were other masses. Age ranged from 3 years to 80 years with the mean age of 42.6 years. There were 59 men and 41 women. The Sensitivity was 72%, Specificity 87%, PPV 85%, NPV 75% and diagnostic Accuracy 79%. In this study we had also 26% false negative and 15% false positive. FNA is a valuable diagnostic tool in the management of neck masses; also it has been used for staging and planning of treatment for the wide and metastatic malignancy. This technique reduces the need for more invasive and costly procedures. According to the high sensitivity and high accuracy in this study, FNA can be used as the first step of diagnoses test in neck masses.

  12. First experiment on LMJ facility: pointing and synchronisation qualification, sequences qualification

    NASA Astrophysics Data System (ADS)

    Henry, Olivier; Raffestin, Didier; Bretheau, Dominique; Luttmann, Michel; Graillot, Herve; Ferri, Michel; Seguineau, Frederic; Bar, Emmanuel; Patissou, Loic; Canal, Philippe; Sautarel, Françoise; Tranquille-Marques, Yves

    2015-11-01

    The LMJ (Laser mega Joule) facility at the CESTA site (Aquitaine, France) is a tool designed to deliver up to 1.2 MJ at 351 nm. The experiment system will include plasma diagnostics: UV and X energy balances, imagers (Streak and stripe camera, CCD), spectrometers, and a Visar/pyrometer. The facility must be able to deliver, within the hour following the shot, all the results of the plasma diagnostics, alignment images and laser diagnostic measurements. Part of the end of 2014 was devoted to the qualification of system pointing on target and synchronization within and between beams. The shots made with one chain (divided in 2 quads - 8 laser beams) have achieved 50 μm of misalignment accuracy and a synchronization accuracy in the order of 50 ps. The performances achieved for plasma diagnostic (in the order of less 100 μm of alignment and timing accuracy less than 150 ps) comply with expectations. At the same time the first automatic sequences were tested. They allowed a shot on target every 6h:30 and in some case twice a day by reducing preparation actions, leading to a sequence of 4h:00. These shooting sequences are managed by an operating team of 7 people helped by 3 people for security aspects.

  13. CSF lactate for accurate diagnosis of community-acquired bacterial meningitis.

    PubMed

    Giulieri, S; Chapuis-Taillard, C; Jaton, K; Cometta, A; Chuard, C; Hugli, O; Du Pasquier, R; Bille, J; Meylan, P; Manuel, O; Marchetti, O

    2015-10-01

    CSF lactate measurement is recommended when nosocomial meningitis is suspected, but its value in community-acquired bacterial meningitis is controversial. We evaluated the diagnostic performance of lactate and other CSF parameters in a prospective cohort of adult patients with acute meningitis. Diagnostic accuracy of lactate and other CSF parameters in patients with microbiologically documented episodes was assessed by receiver operating characteristic (ROC) curves. The cut-offs with the best diagnostic performance were determined. Forty-five of 61 patients (74%) had a documented bacterial (n = 18; S. pneumoniae, 11; N. meningitidis, 5; other, 2) or viral (n = 27 enterovirus, 21; VZV, 3; other, 3) etiology. CSF parameters were significantly different in bacterial vs. viral meningitis, respectively (p < 0.001 for all comparisons): white cell count (median 1333 vs. 143/mm(3)), proteins (median 4115 vs. 829 mg/l), CSF/blood glucose ratio (median 0.1 vs. 0.52), lactate (median 13 vs. 2.3 mmol/l). ROC curve analysis showed that CSF lactate had the highest accuracy for discriminating bacterial from viral meningitis, with a cutoff set at 3.5 mmol/l providing 100% sensitivity, specificity, PPV, NPV, and efficiency. CSF lactate had the best accuracy for discriminating bacterial from viral meningitis and should be included in the initial diagnostic workup of this condition.

  14. Diagnostic potential of Raman spectroscopy in Barrett's esophagus

    NASA Astrophysics Data System (ADS)

    Wong Kee Song, Louis-Michel; Molckovsky, Andrea; Wang, Kenneth K.; Burgart, Lawrence J.; Dolenko, Brion; Somorjai, Rajmund L.; Wilson, Brian C.

    2005-04-01

    Patients with Barrett's esophagus (BE) undergo periodic endoscopic surveillance with random biopsies in an effort to detect dysplastic or early cancerous lesions. Surveillance may be enhanced by near-infrared Raman spectroscopy (NIRS), which has the potential to identify endoscopically-occult dysplastic lesions within the Barrett's segment and allow for targeted biopsies. The aim of this study was to assess the diagnostic performance of NIRS for identifying dysplastic lesions in BE in vivo. Raman spectra (Pexc=70 mW; t=5 s) were collected from Barrett's mucosa at endoscopy using a custom-built NIRS system (λexc=785 nm) equipped with a filtered fiber-optic probe. Each probed site was biopsied for matching histological diagnosis as assessed by an expert pathologist. Diagnostic algorithms were developed using genetic algorithm-based feature selection and linear discriminant analysis, and classification was performed on all spectra with a bootstrap-based cross-validation scheme. The analysis comprised 192 samples (112 non-dysplastic, 54 low-grade dysplasia and 26 high-grade dysplasia/early adenocarcinoma) from 65 patients. Compared with histology, NIRS differentiated dysplastic from non-dysplastic Barrett's samples with 86% sensitivity, 88% specificity and 87% accuracy. NIRS identified 'high-risk' lesions (high-grade dysplasia/early adenocarcinoma) with 88% sensitivity, 89% specificity and 89% accuracy. In the present study, NIRS classified Barrett's epithelia with high and clinically-useful diagnostic accuracy.

  15. First experiment on LMJ facility: pointing and synchronisation qualification

    NASA Astrophysics Data System (ADS)

    Henry, Olivier; Raffestin, Didier; Bretheau, Dominique; Luttmann, Michel; Graillot, Herve; Ferri, Michel; Seguineau, Frederic; Bar, Emmanuel; Patissou, Loic; Canal, Philippe; Sautarel, Franöise; Tranquille-Marques, Yves

    2017-10-01

    The LMJ (Laser mega Joule) facility at the CESTA site (Aquitaine, France) is a tool designed to deliver up to 1.2 MJ at 351 nm for plasma experiments. The experiment system will include 11 diagnostics: UV and X energy balances, imagers (Streak and stripe camera, CCD), spectrometers, and a Visar/pyrometer. The facility must be able to deliver, within the hour following the shot, all the results of the plasma diagnostics, alignment images and laser diagnostic measurements. These results have to be guaranteed in terms of conformity to the request and quality of measurement. The end of 2016 was devoted to the qualification of system pointing on target and synchronization within and between beams. The shots made with two chains (divided in 4 quads - 8 laser beams) have achieved 50 µm of misalignment accuracy (chain and quad channel) and a synchronization accuracy in the order of 50 ps . The performances achieved for plasma diagnostic (in the order of less 100 µm of alignment and timing accuracy less than 150 ps) comply with expectations. At the same time the first automatic sequences were tested. They allowed a shot on target every 6h:30 and in some case twice a day by reducing preparation actions, leading to a sequence of 4h:00.

  16. Measures of accuracy and performance of diagnostic tests.

    PubMed

    Drobatz, Kenneth J

    2009-05-01

    Diagnostic tests are integral to the practice of veterinary cardiology, any other specialty, and general veterinary medicine. Developing and understanding diagnostic tests is one of the cornerstones of clinical research. This manuscript describes the diagnostic test properties including sensitivity, specificity, predictive value, likelihood ratio, receiver operating characteristic curve. Review of practical book chapters and standard statistics manuscripts. Diagnostics such as sensitivity, specificity, predictive value, likelihood ratio, and receiver operating characteristic curve are described and illustrated. Basic understanding of how diagnostic tests are developed and interpreted is essential in reviewing clinical scientific papers and understanding evidence based medicine.

  17. Rapid, comprehensive, and affordable mycobacterial diagnosis with whole-genome sequencing: a prospective study

    PubMed Central

    Pankhurst, Louise J; del Ojo Elias, Carlos; Votintseva, Antonina A; Walker, Timothy M; Cole, Kevin; Davies, Jim; Fermont, Jilles M; Gascoyne-Binzi, Deborah M; Kohl, Thomas A; Kong, Clare; Lemaitre, Nadine; Niemann, Stefan; Paul, John; Rogers, Thomas R; Roycroft, Emma; Smith, E Grace; Supply, Philip; Tang, Patrick; Wilcox, Mark H; Wordsworth, Sarah; Wyllie, David; Xu, Li; Crook, Derrick W

    2016-01-01

    Summary Background Slow and cumbersome laboratory diagnostics for Mycobacterium tuberculosis complex (MTBC) risk delayed treatment and poor patient outcomes. Whole-genome sequencing (WGS) could potentially provide a rapid and comprehensive diagnostic solution. In this prospective study, we compare real-time WGS with routine MTBC diagnostic workflows. Methods We compared sequencing mycobacteria from all newly positive liquid cultures with routine laboratory diagnostic workflows across eight laboratories in Europe and North America for diagnostic accuracy, processing times, and cost between Sept 6, 2013, and April 14, 2014. We sequenced specimens once using local Illumina MiSeq platforms and processed data centrally using a semi-automated bioinformatics pipeline. We identified species or complex using gene presence or absence, predicted drug susceptibilities from resistance-conferring mutations identified from reference-mapped MTBC genomes, and calculated genetic distance to previously sequenced UK MTBC isolates to detect outbreaks. WGS data processing and analysis was done by staff masked to routine reference laboratory and clinical results. We also did a microcosting analysis to assess the financial viability of WGS-based diagnostics. Findings Compared with routine results, WGS predicted species with 93% (95% CI 90–96; 322 of 345 specimens; 356 mycobacteria specimens submitted) accuracy and drug susceptibility also with 93% (91–95; 628 of 672 specimens; 168 MTBC specimens identified) accuracy, with one sequencing attempt. WGS linked 15 (16% [95% CI 10–26]) of 91 UK patients to an outbreak. WGS diagnosed a case of multidrug-resistant tuberculosis before routine diagnosis was completed and discovered a new multidrug-resistant tuberculosis cluster. Full WGS diagnostics could be generated in a median of 9 days (IQR 6–10), a median of 21 days (IQR 14–32) faster than final reference laboratory reports were produced (median of 31 days [IQR 21–44]), at a cost of £481 per culture-positive specimen, whereas routine diagnosis costs £518, equating to a WGS-based diagnosis cost that is 7% cheaper annually than are present diagnostic workflows. Interpretation We have shown that WGS has a scalable, rapid turnaround, and is a financially feasible method for full MTBC diagnostics. Continued improvements to mycobacterial processing, bioinformatics, and analysis will improve the accuracy, speed, and scope of WGS-based diagnosis. Funding National Institute for Health Research, Department of Health, Wellcome Trust, British Colombia Centre for Disease Control Foundation for Population and Public Health, Department of Clinical Microbiology, Trinity College Dublin. PMID:26669893

  18. Raman microspectroscopy of nucleus and cytoplasm for human colon cancer diagnosis.

    PubMed

    Liu, Wenjing; Wang, Hongbo; Du, Jingjing; Jing, Chuanyong

    2017-11-15

    Subcellular Raman analysis is a promising clinic tool for cancer diagnosis, but constrained by the difficulty of deciphering subcellular spectra in actual human tissues. We report a label-free subcellular Raman analysis for use in cancer diagnosis that integrates subcellular signature spectra by subtracting cytoplasm from nucleus spectra (Nuc.-Cyt.) with a partial least squares-discriminant analysis (PLS-DA) model. Raman mapping with the classical least-squares (CLS) model allowed direct visualization of the distribution of the cytoplasm and nucleus. The PLS-DA model was employed to evaluate the diagnostic performance of five types of spectral datasets, including non-selective, nucleus, cytoplasm, ratio of nucleus to cytoplasm (Nuc./Cyt.), and nucleus minus cytoplasm (Nuc.-Cyt.), resulting in diagnostic sensitivity of 88.3%, 84.0%, 98.4%, 84.5%, and 98.9%, respectively. Discriminating between normal and cancerous cells of actual human tissues through subcellular Raman markers is feasible, especially when using the nucleus-cytoplasm difference spectra. The subcellular Raman approach had good stability, and had excellent diagnostic performance for rectal as well as colon tissues. The insights gained from this study shed new light on the general applicability of subcellular Raman analysis in clinical trials. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Improving utility of brain tumor confocal laser endomicroscopy: objective value assessment and diagnostic frame detection with convolutional neural networks

    NASA Astrophysics Data System (ADS)

    Izadyyazdanabadi, Mohammadhassan; Belykh, Evgenii; Martirosyan, Nikolay; Eschbacher, Jennifer; Nakaji, Peter; Yang, Yezhou; Preul, Mark C.

    2017-03-01

    Confocal laser endomicroscopy (CLE), although capable of obtaining images at cellular resolution during surgery of brain tumors in real time, creates as many non-diagnostic as diagnostic images. Non-useful images are often distorted due to relative motion between probe and brain or blood artifacts. Many images, however, simply lack diagnostic features immediately informative to the physician. Examining all the hundreds or thousands of images from a single case to discriminate diagnostic images from nondiagnostic ones can be tedious. Providing a real time diagnostic value assessment of images (fast enough to be used during the surgical acquisition process and accurate enough for the pathologist to rely on) to automatically detect diagnostic frames would streamline the analysis of images and filter useful images for the pathologist/surgeon. We sought to automatically classify images as diagnostic or non-diagnostic. AlexNet, a deep-learning architecture, was used in a 4-fold cross validation manner. Our dataset includes 16,795 images (8572 nondiagnostic and 8223 diagnostic) from 74 CLE-aided brain tumor surgery patients. The ground truth for all the images is provided by the pathologist. Average model accuracy on test data was 91% overall (90.79 % accuracy, 90.94 % sensitivity and 90.87 % specificity). To evaluate the model reliability we also performed receiver operating characteristic (ROC) analysis yielding 0.958 average for area under ROC curve (AUC). These results demonstrate that a deeply trained AlexNet network can achieve a model that reliably and quickly recognizes diagnostic CLE images.

  20. The Feasibility of Classifying Breast Masses Using a Computer-Assisted Diagnosis (CAD) System Based on Ultrasound Elastography and BI-RADS Lexicon.

    PubMed

    Fleury, Eduardo F C; Gianini, Ana Claudia; Marcomini, Karem; Oliveira, Vilmar

    2018-01-01

    To determine the applicability of a computer-aided diagnostic system strain elastography system for the classification of breast masses diagnosed by ultrasound and scored using the criteria proposed by the breast imaging and reporting data system ultrasound lexicon and to determine the diagnostic accuracy and interobserver variability. This prospective study was conducted between March 1, 2016, and May 30, 2016. A total of 83 breast masses subjected to percutaneous biopsy were included. Ultrasound elastography images before biopsy were interpreted by 3 radiologists with and without the aid of computer-aided diagnostic system for strain elastography. The parameters evaluated by each radiologist results were sensitivity, specificity, and diagnostic accuracy, with and without computer-aided diagnostic system for strain elastography. Interobserver variability was assessed using a weighted κ test and an intraclass correlation coefficient. The areas under the receiver operating characteristic curves were also calculated. The areas under the receiver operating characteristic curve were 0.835, 0.801, and 0.765 for readers 1, 2, and 3, respectively, without computer-aided diagnostic system for strain elastography, and 0.900, 0.926, and 0.868, respectively, with computer-aided diagnostic system for strain elastography. The intraclass correlation coefficient between the 3 readers was 0.6713 without computer-aided diagnostic system for strain elastography and 0.811 with computer-aided diagnostic system for strain elastography. The proposed computer-aided diagnostic system for strain elastography system has the potential to improve the diagnostic performance of radiologists in breast examination using ultrasound associated with elastography.

Top