Grilo, C M; Skodol, A E; Gunderson, J G; Sanislow, C A; Stout, R L; Shea, M T; Morey, L C; Zanarini, M C; Bender, D S; Yen, S; McGlashan, T H
2004-07-01
To examine the longitudinal diagnostic efficiency of the DSM-IV criteria for obsessive-compulsive personality disorder (OCPD). At baseline, criteria and diagnoses were determined using diagnostic interviews, and blinded assessments were performed 24 months later with 550 participants. Diagnostic efficiency indices (conditional probabilities, total predictive power, and kappa) were calculated for each criterion determined at baseline, using the independent OCPD diagnosis at follow-up as the standard. Longitudinal diagnostic efficiencies for the OCPD criteria varied; findings suggested the overall predictive utility of 'preoccupied with details', 'rigid and stubborn', and 'reluctant to delegate'. These findings suggest the predictive validity of three cognitive-interpersonal OCPD criteria.
ERIC Educational Resources Information Center
Grilo, Carlos M.; Becker, Daniel F.; Anez, Luis Miguel; McGlashan, Thomas H.
2004-01-01
This study examined diagnostic efficiency of Diagnostic and Statistical Manual of Mental Disorders, fourth edition (DSM-IV), criteria for borderline personality disorder (BPD). One hundred thirty monolingual Hispanic adults (90 men, 40 women) at an outpatient psychiatric and substance abuse clinic were assessed with the Spanish-Language Version of…
McDonald, Scott D; Beckham, Jean C; Morey, Rajendra A; Calhoun, Patrick S
2009-03-01
The present study examined the psychometric properties and diagnostic efficiency of the Davidson Trauma Scale (DTS), a self-report measure of posttraumatic stress disorder (PTSD) symptoms. Participants included 158 U.S. military veterans who have served since September 11, 2001 (post-9/11). Results support the DTS as a valid self-report measure of PTSD symptoms. The DTS demonstrated good internal consistency, concurrent validity, and convergent and divergent validity. Diagnostic efficiency was excellent when discriminating between veterans with PTSD and veterans with no Axis I diagnosis. However, although satisfactory by conventional standards, efficiency was substantially attenuated when discriminating between PTSD and other Axis I diagnoses. Thus, results illustrate that potency of the DTS as a diagnostic aid was highly dependent on the comparison group used for analyses. Results are discussed in terms of applications to clinical practice and research.
ERIC Educational Resources Information Center
Hilsenroth, Mark J.; Eudell-Simmons, Erin M.; DeFife, Jared A.; Charnas, Jocelyn W.
2007-01-01
This study investigates the reliability, validity, and diagnostic efficiency of the Rorschach Perceptual-Thinking Index (PTI) in relation to the accurate identification of psychotic disorder (PTD) patients. The PTI is a revision of the Rorschach Schizophrenia Index (SCZI), designed to achieve several criteria, including an increase in the…
A new condition for assessing the clinical efficiency of a diagnostic test.
Bokhari, Ehsan; Hubert, Lawrence
2015-09-01
When prediction using a diagnostic test outperforms simple prediction using base rates, the test is said to be "clinically efficient," a term first introduced into the literature by Meehl and Rosen (1955) in Psychological Bulletin. This article provides three equivalent conditions for determining the clinical efficiency of a diagnostic test: (a) Meehl-Rosen (Meehl & Rosen, 1955); (b) Dawes (Dawes, 1962); and (c) the Bokhari-Hubert condition, introduced here for the first time. Clinical efficiency is then generalized to situations where misclassification costs are considered unequal (for example, false negatives are more costly than false positives). As an illustration, the clinical efficiency of an actuarial device for predicting violent and dangerous behavior is examined that was developed as part of the MacArthur Violence Risk Assessment Study. (c) 2015 APA, all rights reserved.
Grilo, C M
2004-01-01
This study examined the diagnostic efficiency of the DSM-IV criteria for obsessive compulsive personality disorder (OCPD) in patients with binge eating disorder (BED). Two hundred and eleven consecutive adult patients with axis I diagnoses of BED were reliably assessed with semi-structured diagnostic interviews. Conditional probabilities-sensitivity, specificity, positive predictive power (PPP), and negative predictive power (NPP)-were calculated for each of the eight criteria for OCPD, using the 'best-estimate' OCPD diagnosis as the standard. The diagnostic efficiencies of the OCPD criteria were variable, with three criteria failing to have predictive value (PPP<0.50). The best inclusion criterion (highest PPP) was 'Perfectionism,' which was also the overall most predictive criterion. The findings suggest ordering of the DSM-IV criteria for OCPD based on performance and call into question the utility of some criteria.
McCoy, Thomas H; Castro, Victor M; Snapper, Leslie A; Hart, Kamber L; Perlis, Roy H
2017-08-31
Biobanks and national registries represent a powerful tool for genomic discovery, but rely on diagnostic codes that may be unreliable and fail to capture the relationship between related diagnoses. We developed an efficient means of conducting genome-wide association studies using combinations of diagnostic codes from electronic health records (EHR) for 10845 participants in a biobanking program at two large academic medical centers. Specifically, we applied latent Dirichilet allocation to fit 50 disease topics based on diagnostic codes, then conducted genome-wide common-variant association for each topic. In sensitivity analysis, these results were contrasted with those obtained from traditional single-diagnosis phenome-wide association analysis, as well as those in which only a subset of diagnostic codes are included per topic. In meta-analysis across three biobank cohorts, we identified 23 disease-associated loci with p<1e-15, including previously associated autoimmune disease loci. In all cases, observed significant associations were of greater magnitude than for single phenome-wide diagnostic codes, and incorporation of less strongly-loading diagnostic codes enhanced association. This strategy provides a more efficient means of phenome-wide association in biobanks with coded clinical data.
McCoy, Thomas H; Castro, Victor M; Snapper, Leslie A; Hart, Kamber L; Perlis, Roy H
2017-01-01
Biobanks and national registries represent a powerful tool for genomic discovery, but rely on diagnostic codes that can be unreliable and fail to capture relationships between related diagnoses. We developed an efficient means of conducting genome-wide association studies using combinations of diagnostic codes from electronic health records for 10,845 participants in a biobanking program at two large academic medical centers. Specifically, we applied latent Dirichilet allocation to fit 50 disease topics based on diagnostic codes, then conducted a genome-wide common-variant association for each topic. In sensitivity analysis, these results were contrasted with those obtained from traditional single-diagnosis phenome-wide association analysis, as well as those in which only a subset of diagnostic codes were included per topic. In meta-analysis across three biobank cohorts, we identified 23 disease-associated loci with p < 1e-15, including previously associated autoimmune disease loci. In all cases, observed significant associations were of greater magnitude than single phenome-wide diagnostic codes, and incorporation of less strongly loading diagnostic codes enhanced association. This strategy provides a more efficient means of identifying phenome-wide associations in biobanks with coded clinical data. PMID:28861588
2014-01-01
Objective To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Method Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Results Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. Conclusions This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses. PMID:23965298
Youngstrom, Eric A
2014-03-01
To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses.
[Prenatal diagnostics of chromosomal aberrations Czech Republic: 1994-2007].
Gregor, V; Sípek, A; Sípek, A; Horácek, J '; Langhammer, P; Petrzílková, L; Calda, P
2009-02-01
An analysis of prenatal diagnostics efficiency of selected types of chromosomal aberrations in the Czech Republic in 2007. Update of 1994-2007 data according to particular selected diagnoses. Retrospective epidemiological analysis of pre- and postnatal chromosomal aberrations diagnostics and its efficiency. Data on pre- and postnatally diagnosed birth defects in the Czech Republic during 1994-2007 were used. Data on prenatally diagnosed birth defects (and for terminated pregnancies) were collected from particular departments of prenatal diagnostics, medical genetics and ultrasound diagnostics in the Czech Republic, data on birth defects in births from the National Birth Defects Register (Institute for Health Information and Statistics). Total numbers over the period under the study, mean incidences of selected types of chromosomal aberrations and mean prenatal diagnostics efficiencies were analyzed. Following chromosomal aberrations were studied: Down, Edwards, Patau, Turner and Klinefelter syndromes and syndromes 47,XXX and 47,XYY. A relative proportion of Down, Edwards and Patau syndromes as well as other autosomal and gonosomal aberration is presented in figures. Recently, trisomies 13, 18 and 21 present around 70% of all chromosomal aberrations in selectively aborted fetuses, in other pregnancies, "other chromosomal aberrations" category (mostly balanced reciprocal translocations and inversions) present more than 2/3 of all diagnoses. During the period under the study, following total numbers, mean relative incidences (per 10,000 live births, in brackets) and mean prenatal diagnostics efficiency (in %) were found in following chromosomal syndromes: Down syndrome 2,244 (16.58) and 63.37%, Edwards syndrome 521 (3.85) and 79.93%, Patau syndrome 201 (1.49) and 68.87%, Turner syndrome 380 (2.81) and 79.89%, 47,XXX syndrome 61 (0.45) and 59.74%, Klinefelter syndrome 163 (1.20) and 73.65% and 47,XYY syndrome 22 (0.16) and 54.76%. The study gives updated results of incidences analysis of both pre- and postnatally diagnosed chromosomal birth defects in the Czech Republic during the 1994-2007 period. Incidences found in our study correspond (in case of trisomies 13, 18 and 21) with those published widely in literature as well as with those found in large-scale international studies (ICBDSR, EUROCAT). In case of gonosomal aberrations, incidences found in this study are lower that those published, most probably due to a later registration (over 15 years of age of the child) of these diagnoses.
Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents
Garcia-Lopez, LuisJoaquín; Moore, Harry T. A.
2015-01-01
Objectives Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. Methods The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Results Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Conclusions Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided. PMID:26317695
Validation and Diagnostic Efficiency of the Mini-SPIN in Spanish-Speaking Adolescents.
Garcia-Lopez, LuisJoaquín; Moore, Harry T A
2015-01-01
Social Anxiety Disorder (SAD) is one of the most common mental disorders in adolescence. Many validated psychometric tools are available to diagnose individuals with SAD efficaciously. However, there is a demand for shortened self-report instruments that identify adolescents at risk of developing SAD. We validate the Mini-SPIN and its diagnostic efficiency in overcoming this problem in Spanish-speaking adolescents in Spain. The psychometric properties of the 3-item Mini-SPIN scale for adolescents were assessed in a community (study 1) and clinical sample (study 2). Study 1 consisted of 573 adolescents, and found the Mini-SPIN to have appropriate internal consistency and high construct validity. Study 2 consisted of 354 adolescents (147 participants diagnosed with SAD and 207 healthy controls). Data revealed that the Mini-SPIN has good internal consistency, high construct validity and adequate diagnostic efficiency. Our findings suggest that the Mini-SPIN has good psychometric properties on clinical and healthy control adolescents and general population, which indicates that it can be used as a screening tool in Spanish-speaking adolescents. Cut-off scores are provided.
Becker, Daniel F; Añez, Luis Miguel; Paris, Manuel; Bedregal, Luis; Grilo, Carlos M
2009-01-01
This study examined the internal consistency, factor structure, and diagnostic efficiency of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV), criteria for avoidant personality disorder (AVPD) and the extent to which these metrics may be affected by sex. Subjects were 130 monolingual Hispanic adults (90 men, 40 women) who had been admitted to a specialty clinic that provides psychiatric and substance abuse services to Spanish-speaking patients. All were reliably assessed with the Spanish-Language Version of the Diagnostic Interview for DSM-IV Personality Disorders. The AVPD diagnosis was determined by the best-estimate method. After evaluating internal consistency of the AVPD criterion set, an exploratory factor analysis was performed using principal components extraction. Afterward, diagnostic efficiency indices were calculated for all AVPD criteria. Subsequent analyses examined men and women separately. For the overall group, internal consistency of AVPD criteria was good. Exploratory factor analysis revealed a 1-factor solution (accounting for 70% of the variance), supporting the unidimensionality of the AVPD criterion set. The best inclusion criterion was "reluctance to take risks," whereas "interpersonally inhibited" was the best exclusion criterion and the best predictor overall. When men and women were examined separately, similar results were obtained for both internal consistency and factor structure, with slight variations noted between sexes in the patterning of diagnostic efficiency indices. These psychometric findings, which were similar for men and women, support the construct validity of the DSM-IV criteria for AVPD and may also have implications for the treatment of this particular clinical population.
Wu, Li; Lin, Huandong; Gao, Jian; Li, Xiaoming; Xia, Mingfeng; Wang, Dan; Aleteng, Qiqige; Ma, Hui; Pan, Baishen; Gao, Xin
2017-01-01
Glycated hemoglobin A1c (HbA1c) ≥6.5% (or 48mmol/mol) has been recommended as a new diagnostic criterion for diabetes; however, limited literature is available regarding the effect of age on the HbA1c for diagnosing diabetes and the causes for this age effect remain unknown. In this study, we investigated whether and why age affects the diagnostic efficiency of HbA1c for diabetes in a community-based Chinese population. In total, 4325 participants without previously known diabetes were enrolled in this study. Participants were stratified by age. Receiver operating characteristic curve (ROC) was plotted for each age group and the area under the curve (AUC) represented the diagnostic efficiency of HbA1c for diabetes defined by the plasma glucose criteria. The area under the ROC curve in each one-year age group was defined as AUCage. Multiple regression analyses were performed to identify factors inducing the association between age and AUCage based on the changes in the β and P values of age. The current threshold of HbA1c (≥6.5% or 48mmol/mol) showed low sensitivity (35.6%) and high specificity (98.9%) in diagnosing diabetes. ROC curve analyses showed that the diagnostic efficiency of HbA1c in the ≥75 years age group was significantly lower than that in the 45-54 years age group (AUC: 0.755 vs. 0.878; P<0.001). Pearson correlation analysis showed that the AUCage of HbA1c was negatively correlated with age (r = -0.557, P = 0.001). When adjusting the red blood cell (RBC) count in the multiple regression model, the negative association between age and AUCage disappeared, with the regression coefficient of age reversed to 0.001 and the P value increased to 0.856. The diagnostic efficiency of HbA1c for diabetes decreased with aging, and this age effect was induced by the decreasing RBC count with age. HbA1c is unsuitable for diagnosing diabetes in elderly individuals because of their physiologically decreased RBC count.
Gao, Jian; Li, Xiaoming; Xia, Mingfeng; Wang, Dan; Aleteng, Qiqige; Ma, Hui; Pan, Baishen
2017-01-01
Background and aims Glycated hemoglobin A1c (HbA1c) ≥6.5% (or 48mmol/mol) has been recommended as a new diagnostic criterion for diabetes; however, limited literature is available regarding the effect of age on the HbA1c for diagnosing diabetes and the causes for this age effect remain unknown. In this study, we investigated whether and why age affects the diagnostic efficiency of HbA1c for diabetes in a community-based Chinese population. Methods In total, 4325 participants without previously known diabetes were enrolled in this study. Participants were stratified by age. Receiver operating characteristic curve (ROC) was plotted for each age group and the area under the curve (AUC) represented the diagnostic efficiency of HbA1c for diabetes defined by the plasma glucose criteria. The area under the ROC curve in each one-year age group was defined as AUCage. Multiple regression analyses were performed to identify factors inducing the association between age and AUCage based on the changes in the β and P values of age. Results The current threshold of HbA1c (≥6.5% or 48mmol/mol) showed low sensitivity (35.6%) and high specificity (98.9%) in diagnosing diabetes. ROC curve analyses showed that the diagnostic efficiency of HbA1c in the ≥75 years age group was significantly lower than that in the 45–54 years age group (AUC: 0.755 vs. 0.878; P<0.001). Pearson correlation analysis showed that the AUCage of HbA1c was negatively correlated with age (r = -0.557, P = 0.001). When adjusting the red blood cell (RBC) count in the multiple regression model, the negative association between age and AUCage disappeared, with the regression coefficient of age reversed to 0.001 and the P value increased to 0.856. Conclusions The diagnostic efficiency of HbA1c for diabetes decreased with aging, and this age effect was induced by the decreasing RBC count with age. HbA1c is unsuitable for diagnosing diabetes in elderly individuals because of their physiologically decreased RBC count. PMID:28886160
Informativeness of Diagnostic Marker Values and the Impact of Data Grouping.
Ma, Hua; Bandos, Andriy I; Gur, David
2018-01-01
Assessing performance of diagnostic markers is a necessary step for their use in decision making regarding various conditions of interest in diagnostic medicine and other fields. Globally useful markers could, however, have ranges of values that are " diagnostically non-informative" . This paper demonstrates that the presence of marker values from diagnostically non-informative ranges could lead to a loss in statistical efficiency during nonparametric evaluation and shows that grouping non-informative values provides a natural resolution to this problem. These points are theoretically proven and an extensive simulation study is conducted to illustrate the possible benefits of using grouped marker values in a number of practically reasonable scenarios. The results contradict the common conjecture regarding the detrimental effect of grouped marker values during performance assessments. Specifically, contrary to the common assumption that grouped marker values lead to bias, grouping non-informative values does not introduce bias and could substantially reduce sampling variability. The proven concept that grouped marker values could be statistically beneficial without detrimental consequences implies that in practice, tied values do not always require resolution whereas the use of continuous diagnostic results without addressing diagnostically non-informative ranges could be statistically detrimental. Based on these findings, more efficient methods for evaluating diagnostic markers could be developed.
Can and should value-based pricing be applied to molecular diagnostics?
Garau, Martina; Towse, Adrian; Garrison, Louis; Housman, Laura; Ossa, Diego
2013-01-01
Current pricing and reimbursement systems for diagnostics are not efficient. Prices for diagnostics are often driven by administrative practices and expected production cost. The purpose of the paper is to discuss how a value-based pricing framework being used to ensure efficient use and price of medicines could also be applied to diagnostics. Diagnostics not only facilitates health gain and cost savings, but also information to guide patients' decisions on interventions and their future 'behaviors'. For value assessment processes we recommend a two-part approach. Companion diagnostics introduced at the launch of the drug should be assessed through new drug assessment processes considering a broad range of value elements and a balanced analysis of diagnostic impacts. A separate diagnostic-dedicated committee using value-based pricing principles should review other diagnostics lying outside the companion diagnostics-and-drug 'at-launch' situation.
NASA Astrophysics Data System (ADS)
Xu, Jiuping; Zhong, Zhengqiang; Xu, Lei
2015-10-01
In this paper, an integrated system health management-oriented adaptive fault diagnostics and model for avionics is proposed. With avionics becoming increasingly complicated, precise and comprehensive avionics fault diagnostics has become an extremely complicated task. For the proposed fault diagnostic system, specific approaches, such as the artificial immune system, the intelligent agents system and the Dempster-Shafer evidence theory, are used to conduct deep fault avionics diagnostics. Through this proposed fault diagnostic system, efficient and accurate diagnostics can be achieved. A numerical example is conducted to apply the proposed hybrid diagnostics to a set of radar transmitters on an avionics system and to illustrate that the proposed system and model have the ability to achieve efficient and accurate fault diagnostics. By analyzing the diagnostic system's feasibility and pragmatics, the advantages of this system are demonstrated.
NASA Astrophysics Data System (ADS)
Urnes, James M., Sr.; Cushing, John; Bond, William E.; Nunes, Steve
1996-10-01
Fly-by-Light control systems offer higher performance for fighter and transport aircraft, with efficient fiber optic data transmission, electric control surface actuation, and multi-channel high capacity centralized processing combining to provide maximum aircraft flight control system handling qualities and safety. The key to efficient support for these vehicles is timely and accurate fault diagnostics of all control system components. These diagnostic tests are best conducted during flight when all facts relating to the failure are present. The resulting data can be used by the ground crew for efficient repair and turnaround of the aircraft, saving time and money in support costs. These difficult to diagnose (Cannot Duplicate) fault indications average 40 - 50% of maintenance activities on today's fighter and transport aircraft, adding significantly to fleet support cost. Fiber optic data transmission can support a wealth of data for fault monitoring; the most efficient method of fault diagnostics is accurate modeling of the component response under normal and failed conditions for use in comparison with the actual component flight data. Neural Network hardware processors offer an efficient and cost-effective method to install fault diagnostics in flight systems, permitting on-board diagnostic modeling of very complex subsystems. Task 2C of the ARPA FLASH program is a design demonstration of this diagnostics approach, using the very high speed computation of the Adaptive Solutions Neural Network processor to monitor an advanced Electrohydrostatic control surface actuator linked through a AS-1773A fiber optic bus. This paper describes the design approach and projected performance of this on-line diagnostics system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S; Ji, Y; Kim, K
Purpose: A diagnostics Multileaf Collimator (MLC) was designed for diagnostic radiography dose reduction. Monte Carlo simulation was used to evaluate efficiency of shielding material for producing leaves of Multileaf collimator. Material & Methods: The general radiography unit (Rex-650R, Listem, Korea) was modeling with Monte Carlo simulation (MCNPX, LANL, USA) and we used SRS-78 program to calculate the energy spectrum of tube voltage (80, 100, 120 kVp). The shielding materials was SKD 11 alloy tool steel that is composed of 1.6% carbon(C), 0.4% silicon (Si), 0.6% manganese (Mn), 5% chromium (Cr), 1% molybdenum (Mo), and vanadium (V). The density of itmore » was 7.89 g/m3. We simulated leafs diagnostic MLC using SKD 11 with general radiography unit. We calculated efficiency of diagnostic MLC using tally6 card of MCNPX depending on energy. Results: The diagnostic MLC consisted of 25 individual metal shielding leaves on both sides, with dimensions of 10 × 0.5 × 0.5 cm3. The leaves of MLC were controlled by motors positioned on both sides of the MLC. According to energy (tube voltage), the shielding efficiency of MLC in Monte Carlo simulation was 99% (80 kVp), 96% (100 kVp) and 93% (120 kVp). Conclusion: We certified efficiency of diagnostic MLC fabricated from SKD11 alloy tool steel. Based on the results, the diagnostic MLC was designed. We will make the diagnostic MLC for dose reduction of diagnostic radiography.« less
Teacher's Psycho-Diagnostic Activities in School Educational System
ERIC Educational Resources Information Center
Minakhmetova, Albina Z.; Pyanova, Ekaterina N.; Akhmetshina, Enze M.
2016-01-01
The urgency of the problem stated in the article stems from the fact that in modern conditions the study of the psycho-diagnostic component of the teacher's activities is relevant in practical terms, since the functions of these activities affect the efficiency of pedagogical activity and the educational process itself, including the effectiveness…
Arpaia, P; Cimmino, P; Girone, M; La Commara, G; Maisto, D; Manna, C; Pezzetti, M
2014-09-01
Evolutionary approach to centralized multiple-faults diagnostics is extended to distributed transducer networks monitoring large experimental systems. Given a set of anomalies detected by the transducers, each instance of the multiple-fault problem is formulated as several parallel communicating sub-tasks running on different transducers, and thus solved one-by-one on spatially separated parallel processes. A micro-genetic algorithm merges evaluation time efficiency, arising from a small-size population distributed on parallel-synchronized processors, with the effectiveness of centralized evolutionary techniques due to optimal mix of exploitation and exploration. In this way, holistic view and effectiveness advantages of evolutionary global diagnostics are combined with reliability and efficiency benefits of distributed parallel architectures. The proposed approach was validated both (i) by simulation at CERN, on a case study of a cold box for enhancing the cryogeny diagnostics of the Large Hadron Collider, and (ii) by experiments, under the framework of the industrial research project MONDIEVOB (Building Remote Monitoring and Evolutionary Diagnostics), co-funded by EU and the company Del Bo srl, Napoli, Italy.
When Less Is More: How Fewer Diagnostic Criteria Can Indicate Greater Severity
ERIC Educational Resources Information Center
Cooper, Luke D.; Balsis, Steve
2009-01-01
For diagnosing many mental disorders, the current "Diagnostic and Statistical Manual of Mental Disorders" ("DSM") system weights each diagnostic criterion equally--each criterion counts the same toward meeting the diagnostic threshold. Research on the diagnostic efficiency of criteria, however, reveals that some diagnostic criteria are more useful…
ERIC Educational Resources Information Center
Sandberg Patton, Karen L.; Reschly, Amy L.; Appleton, James
2014-01-01
With the concurrent emphasis on accountability, prevention, and early intervention, curriculum-based measurement of reading (R-CBM) is playing an increasingly important role in the educational process. This study investigated the differences in diagnostic accuracy and utility between commercial norms and local norms when making high-stakes, local…
Quantitative optical diagnostics in pathology recognition and monitoring of tissue reaction to PDT
NASA Astrophysics Data System (ADS)
Kirillin, Mikhail; Shakhova, Maria; Meller, Alina; Sapunov, Dmitry; Agrba, Pavel; Khilov, Alexander; Pasukhin, Mikhail; Kondratieva, Olga; Chikalova, Ksenia; Motovilova, Tatiana; Sergeeva, Ekaterina; Turchin, Ilya; Shakhova, Natalia
2017-07-01
Optical coherence tomography (OCT) is currently actively introduced into clinical practice. Besides diagnostics, it can be efficiently employed for treatment monitoring allowing for timely correction of the treatment procedure. In monitoring of photodynamic therapy (PDT) traditionally employed fluorescence imaging (FI) can benefit from complementary use of OCT. Additional diagnostic efficiency can be derived from numerical processing of optical diagnostics data providing more information compared to visual evaluation. In this paper we report on application of OCT together with numerical processing for clinical diagnostic in gynecology and otolaryngology, for monitoring of PDT in otolaryngology and on OCT and FI applications in clinical and aesthetic dermatology. Image numerical processing and quantification provides increase in diagnostic accuracy. Keywords: optical coherence tomography, fluorescence imaging, photod
Song, Lei; Li, Liang; Liu, Bin; Yu, Dexin; Sun, Fengguo; Guo, Mingming; Ruan, Zhengmin; Zhang, Feixue
2018-01-01
The objective of the present study was to evaluate the diagnostic efficiency of ultrasound (US) and magnetic resonance imaging (MRI) in the diagnosis and differential diagnosis of mammary duct ectasia (MDE) and breast cancer. This retrospective study was performed on 35 patients with MDE and 105 patients with breast cancer using US and MRI. Imaging features, semi-quantitative and quantitative parameters were analyzed to determine their diagnostic value for MDE and breast cancer. The average age of patients with breast cancer was increased compared with that of patients with MDE. There were no significant differences in local packages with or without tenderness ratio (P=0.259) and grade of color Doppler flow imaging (P=0.273) between the two groups. However, the morphological changes were significantly increased in breast cancer compared with MDE. In addition, there were significant diagnostic differences in US and MRI between breast cancer and MDE, including resistance index, US elastography, time-signal intensity curve, apparent diffusion coefficient, early-stage enhancement ratio, peak-of-enhancement ratio and Tpeak (P<0.05). However, there were no observable significant diagnostic differences between US, MRI and US with MRI for MDE and breast cancer (P=0.103, P=0.263 and P=0.403 respectively). Diagnosis of MDE and breast cancer requires full evaluation of multiple parameters and morphological changes of US and MRI to increase the diagnostic efficiency. US, MRI and US with MRI were all of diagnostic value for MDE and breast cancer, while US with MRI had the highest efficacy. PMID:29434865
Kuupiel, Desmond; Bawontuo, Vitalis; Mashamba-Thompson, Tivani P
2017-11-29
Access to point-of-care (POC) diagnostics services is essential for ensuring rapid disease diagnosis, management, control, and surveillance. POC testing services can improve access to healthcare especially where healthcare infrastructure is weak and access to quality and timely medical care is a challenge. Improving the accessibility and efficiency of POC diagnostics services, particularly in resource-limited settings, may be a promising route to improving healthcare outcomes. In this review, the accessibility of POC testing is defined as the distance/proximity to the nearest healthcare facility for POC diagnostics service. This review provides an overview of the impact of POC diagnostics on healthcare outcomes in low- and middle-income countries (LMICs) and factors contributing to the accessibility of POC testing services in LMICs, focusing on characteristics of the supply chain management and quality systems management, characteristics of the geographical location, health infrastructure, and an enabling policy framework for POC diagnostics services. Barriers and challenges related to the accessibility of POC diagnostics in LMICs were also discussed. Bearing in mind the reported barriers and challenges as well as the disease epidemiology in LMICs, we propose a lean and agile supply chain management framework for improving the accessibility and efficiency of POC diagnostics services in these settings.
Kuupiel, Desmond; Bawontuo, Vitalis
2017-01-01
Access to point-of-care (POC) diagnostics services is essential for ensuring rapid disease diagnosis, management, control, and surveillance. POC testing services can improve access to healthcare especially where healthcare infrastructure is weak and access to quality and timely medical care is a challenge. Improving the accessibility and efficiency of POC diagnostics services, particularly in resource-limited settings, may be a promising route to improving healthcare outcomes. In this review, the accessibility of POC testing is defined as the distance/proximity to the nearest healthcare facility for POC diagnostics service. This review provides an overview of the impact of POC diagnostics on healthcare outcomes in low- and middle-income countries (LMICs) and factors contributing to the accessibility of POC testing services in LMICs, focusing on characteristics of the supply chain management and quality systems management, characteristics of the geographical location, health infrastructure, and an enabling policy framework for POC diagnostics services. Barriers and challenges related to the accessibility of POC diagnostics in LMICs were also discussed. Bearing in mind the reported barriers and challenges as well as the disease epidemiology in LMICs, we propose a lean and agile supply chain management framework for improving the accessibility and efficiency of POC diagnostics services in these settings. PMID:29186013
Sánchez-Muñoz, Laura; Morgado, Jose M; Álvarez-Twose, Ivan; Matito, Almudena; Garcia-Montero, Andrés C; Teodosio, Cristina; Jara-Acevedo, Maria; Mayado, Andrea; Mollejo, Manuela; Caldas, Carolina; González de Olano, David; Escribano, Luis; Orfao, Alberto
2016-01-01
The diagnosis of 'rare diseases', such as mastocytosis, remains a challenge. Despite this, the precise benefits of referral of mastocytosis patients to highly specialized reference centres are poorly defined and whether patients should be managed at non-specialized versus reference centres remains a matter of debate. To evaluate the quality and efficiency of diagnostic procedures performed at the reference centres for mastocytosis in Spain (REMA) versus other non-reference centres, we retrospectively analysed a series of 122 patients, for the overall degree of agreement obtained for the World Health Organization (WHO) diagnostic and classification criteria betwen the referring and REMA centres. Our results showed that not all WHO diagnostic criteria were frequently investigated at the referring centres. Among the five WHO diagnostic criteria, the highest degree of agreement was obtained for serum tryptase levels [median 90% (95% confidence interval 84-96%)]; in turn, the overall agreement was significantly lower for the major histopathological criterion [80% (72-89%)], and the other three minor criteria: cytomorphology [68% (56-80%)] immunophenotyping of BM mast cells [75% (62-87%)] and detection of the KIT mutation [34% (8-60%)]. Referral of patients with diagnostic suspicion of mastocytosis to a multidisciplinary reference centre improves diagnostic efficiency and quality. © 2015 John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Xavier, Jean; Vannetzel, Leonard; Viaux, Sylvie; Leroy, Arthur; Plaza, Monique; Tordjman, Sylvie; Mille, Christian; Bursztejn, Claude; Cohen, David; Guile, Jean-Marc
2011-01-01
The Pervasive Developmental Disorder-Not Otherwise Specified (PDD-NOS) category is a psychopathological entity few have described and is poorly, and mainly negatively, defined by autism exclusion. In order to limit PDD-NOS heterogeneity, alternative clinical constructs have been developed. This study explored the reliability and the diagnostic…
Diagnostic multiplex PCR for toxin genotyping of Clostridium perfringens isolates.
Baums, Christoph G; Schotte, Ulrich; Amtsberg, Gunter; Goethe, Ralph
2004-05-20
In this study we provide a protocol for genotyping Clostridium perfringens with a new multiplex PCR. This PCR enables reliable and specific detection of the toxin genes cpa, cpb, etx, iap, cpe and cpb2 from heat lysed bacterial suspensions. The efficiency of the protocol was demonstrated by typing C. perfringens reference strains and isolates from veterinary bacteriological routine diagnostic specimens.
Identifying Inefficient Single-Family Homes With Utility Bill Analysis: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Casey, S.; Krarti, M.; Bianchi, M.
2010-08-01
Differentiating between energy-efficient and inefficient single-family homes on a community scale helps identify and prioritize candidates for energy-efficiency upgrades. Prescreening diagnostic procedures can further retrofit efforts by providing efficiency information before a site-visit is conducted. We applied the prescreening diagnostic to a simulated community of homes in Boulder, Colorado and analyzed energy consumption data to identify energy-inefficient homes.
Warren, Amy L; Donnon, Tyrone L; Wagg, Catherine R; Priest, Heather; Fernandez, Nicole J
2018-01-18
Visual diagnostic reasoning is the cognitive process by which pathologists reach a diagnosis based on visual stimuli (cytologic, histopathologic, or gross imagery). Currently, there is little to no literature examining visual reasoning in veterinary pathology. The objective of the study was to use eye tracking to establish baseline quantitative and qualitative differences between the visual reasoning processes of novice and expert veterinary pathologists viewing cytology specimens. Novice and expert participants were each shown 10 cytology images and asked to formulate a diagnosis while wearing eye-tracking equipment (10 slides) and while concurrently verbalizing their thought processes using the think-aloud protocol (5 slides). Compared to novices, experts demonstrated significantly higher diagnostic accuracy (p<.017), shorter time to diagnosis (p<.017), and a higher percentage of time spent viewing areas of diagnostic interest (p<.017). Experts elicited more key diagnostic features in the think-aloud protocol and had more efficient patterns of eye movement. These findings suggest that experts' fast time to diagnosis, efficient eye-movement patterns, and preference for viewing areas of interest supports system 1 (pattern-recognition) reasoning and script-inductive knowledge structures with system 2 (analytic) reasoning to verify their diagnosis.
Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety.
Bekelis, Kimon; Radwan, Tarek A; Desai, Atman; Roberts, David W
2012-05-01
Frameless stereotactic brain biopsy has become an established procedure in many neurosurgical centers worldwide. Robotic modifications of image-guided frameless stereotaxy hold promise for making these procedures safer, more effective, and more efficient. The authors hypothesized that robotic brain biopsy is a safe, accurate procedure, with a high diagnostic yield and a safety profile comparable to other stereotactic biopsy methods. This retrospective study included 41 patients undergoing frameless stereotactic brain biopsy of lesions (mean size 2.9 cm) for diagnostic purposes. All patients underwent image-guided, robotic biopsy in which the SurgiScope system was used in conjunction with scalp fiducial markers and a preoperatively selected target and trajectory. Forty-five procedures, with 50 supratentorial targets selected, were performed. The mean operative time was 44.6 minutes for the robotic biopsy procedures. This decreased over the second half of the study by 37%, from 54.7 to 34.5 minutes (p < 0.025). The diagnostic yield was 97.8% per procedure, with a second procedure being diagnostic in the single nondiagnostic case. Complications included one transient worsening of a preexisting deficit (2%) and another deficit that was permanent (2%). There were no infections. Robotic biopsy involving a preselected target and trajectory is safe, accurate, efficient, and comparable to other procedures employing either frame-based stereotaxy or frameless, nonrobotic stereotaxy. It permits biopsy in all patients, including those with small target lesions. Robotic biopsy planning facilitates careful preoperative study and optimization of needle trajectory to avoid sulcal vessels, bridging veins, and ventricular penetration.
Poor Validity of the DSM-IV Schizoid Personality Disorder Construct as a Diagnostic Category.
Hummelen, Benjamin; Pedersen, Geir; Wilberg, Theresa; Karterud, Sigmund
2015-06-01
This study sought to evaluate the construct validity of schizoid personality disorder (SZPD) by investigating a sample of 2,619 patients from the Norwegian Network of Personality-Focused Treatment Programs by a variety of statistical techniques. Nineteen patients (0.7%) reached the diagnostic threshold of SZPD. Results from the factor analyses indicated that SZPD consists of three factors: social detachment, withdrawal, and restricted affectivity/ anhedonia. Overall, internal consistency and diagnostic efficiency were poor and best for the criteria that belong to the social detachment factor. These findings pose serious questions about the clinical utility of SZPD as a diagnostic category. On the other hand, the three factors were in concordance with findings from previous studies and with the trait model for personality disorders in DSM-5, supporting the validity of SZPD as a dimensional construct. The authors recommend that SZPD should be deleted as a diagnostic category in future editions of DSM-5.
Walker, Alexandra J; Batchelor, Jennifer; Shores, E Arthur; Jones, Mike
2009-11-01
Despite the sensitivity of neuropsychological tests to educational level, improved diagnostic accuracy for demographically corrected scores has yet to be established. Diagnostic efficiency statistics of Wechsler Adult Intelligence Scale-III (WAIS-III) and Wechsler Memory Scale-III (WMS-III) indices that were corrected for education, sex, and age (demographically corrected) were compared with age corrected indices in individuals aged 16 to 75 years with moderate to severe traumatic brain injury (TBI) and 12 years or less education. TBI participants (n = 100) were consecutive referrals to an outpatient rehabilitation service and met careful selection criteria. Controls (n = 100) were obtained from the WAIS-III/WMS-III standardization sample. Demographically corrected indices did not provide higher diagnostic efficiency than age corrected indices and this result was supported by reanalysis of the TBI group against a larger and unmatched control group. Processing Speed Index provided comparable diagnostic accuracy to that of combined indices. Demographically corrected indices were associated with higher cut-scores to maximize overall classification, reflecting the upward adjustment of those scores in a lower education sample. This suggests that, in clinical practice, the test results of individuals with limited education may be more accurately interpreted with the application of demographic corrections. Diagnostic efficiency statistics are presented, and future research directions are discussed.
Installé, Arnaud Jf; Van den Bosch, Thierry; De Moor, Bart; Timmerman, Dirk
2014-10-20
Using machine-learning techniques, clinical diagnostic model research extracts diagnostic models from patient data. Traditionally, patient data are often collected using electronic Case Report Form (eCRF) systems, while mathematical software is used for analyzing these data using machine-learning techniques. Due to the lack of integration between eCRF systems and mathematical software, extracting diagnostic models is a complex, error-prone process. Moreover, due to the complexity of this process, it is usually only performed once, after a predetermined number of data points have been collected, without insight into the predictive performance of the resulting models. The objective of the study of Clinical Data Miner (CDM) software framework is to offer an eCRF system with integrated data preprocessing and machine-learning libraries, improving efficiency of the clinical diagnostic model research workflow, and to enable optimization of patient inclusion numbers through study performance monitoring. The CDM software framework was developed using a test-driven development (TDD) approach, to ensure high software quality. Architecturally, CDM's design is split over a number of modules, to ensure future extendability. The TDD approach has enabled us to deliver high software quality. CDM's eCRF Web interface is in active use by the studies of the International Endometrial Tumor Analysis consortium, with over 4000 enrolled patients, and more studies planned. Additionally, a derived user interface has been used in six separate interrater agreement studies. CDM's integrated data preprocessing and machine-learning libraries simplify some otherwise manual and error-prone steps in the clinical diagnostic model research workflow. Furthermore, CDM's libraries provide study coordinators with a method to monitor a study's predictive performance as patient inclusions increase. To our knowledge, CDM is the only eCRF system integrating data preprocessing and machine-learning libraries. This integration improves the efficiency of the clinical diagnostic model research workflow. Moreover, by simplifying the generation of learning curves, CDM enables study coordinators to assess more accurately when data collection can be terminated, resulting in better models or lower patient recruitment costs.
Nekouei, Omid; Durocher, Jean; Keefe, Greg
2016-07-01
This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs.
Nekouei, Omid; Durocher, Jean; Keefe, Greg
2016-01-01
This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469
Opmeer, B C; van Doorn, H C; Heintz, A P M; Burger, C W; Bossuyt, P M M; Mol, B W J
2007-01-01
The aim of this study was to evaluate whether the efficiency of the current diagnostic work up following postmenopausal bleeding could be improved by diagnostic strategies that take into account characteristics of the women in addition to the currently recommended transvaginal measurement of endometrial thickness to determine for subsequent histological assessment. Multicenter, prospective cohort study. A university hospital and seven teaching hospitals in the Netherlands. Consecutive women not using hormone replacement therapy, presenting with postmenopausal bleeding. Five hundred and forty women underwent transvaginal sonography, and in case of endometrial thickness (double layer) above 4 mm, subsequent endometrial sampling was performed. Presence of carcinoma was ruled out by the absence of abnormalities in histological specimen or by an uneventful follow up of at least 6 months. Probability of endometrial carcinoma was estimated by multivariable logistic regression models. For each diagnostic strategy, we calculated diagnostic accuracy (area under receiver operating characteristic curve [AUC]), negative predictive value (NPV) and the number of diagnostic procedures. A strategy with transvaginal sonography alone with a fixed threshold incorrectly classified 0.7% of the women as nonmalignant (NPV: 99.3% [98.5-100%]), with 97% sensitivity and 56% specificity. A strategy integrating characteristics of the women with transvaginal sonography could result in less false reassurances (NPV: 99.6% [99.2-100%]), with only marginal decrease in diagnostic procedures, or a minor increase in false reassurances (NPV: 99.0% [98.3-100%]), with a substantial reduction (15-20%) in the procedures. AUCs associated with these strategies could improve from 0.76 (0.73-0.79) for transvaginal sonography alone to 0.90 (0.87-0.93) for the integrated strategy. Taking into account the characteristics of the women could increase the efficiency of the diagnostic work up for postmenopausal bleeding.
NASA Technical Reports Server (NTRS)
Mcgary, Michael C.
1988-01-01
The anticipated application of advanced turboprop propulsion systems is expected to increase the interior noise of future aircraft to unacceptably high levels. The absence of technically and economically feasible noise source-path diagnostic tools has been a prime obstacle in the development of efficient noise control treatments for propeller-driven aircraft. A new diagnostic method that permits the separation and prediction of the fully coherent airborne and structureborne components of the sound radiated by plates or thin shells has been developed. Analytical and experimental studies of the proposed method were performed on an aluminum plate. The results of the study indicate that the proposed method could be used in flight, and has fewer encumbrances than the other diagnostic tools currently available.
Cheyletiella infestation in the dog: observations on diagnostic methods and clinical signs.
Saevik, B K; Bredal, W; Ulstein, T L
2004-10-01
The aims of this study were to evaluate the ability of diagnostic methods to detect naturally occurring Cheyletiella infestation in dogs, and to quantify and relate the number of mites and eggs present to clinical signs. Privately owned dogs with skin problems were eligible for inclusion in the study. Four diagnostic tests were performed on each dog in the following order: tape impression, hair plucking, skin scraping and vacuum cleaning. Dogs with positive test results for Cheyletiella infestation in at least one of the tests under evaluation were included in the study (n=27). The severity of pruritus and scaling was graded on a four-point fixed scale. The diagnostic findings in vacuum cleaning samples provided a semiquantitative measure of the grade of infestation. The vacuum cleaning test gave a positive test result in all dogs and was significantly more efficient than the other tests evaluated (P<0.01). The number of diagnostic findings varied considerably among the different vacuum samples. No significant relationship between the number of diagnostic findings and severity of clinical signs was detected.
Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao
2014-01-01
Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179
Efficient strategies to find diagnostic test accuracy studies in kidney journals.
Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C
2015-08-01
Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.
Crawford, Eric F; Fulton, Jessica J; Swinkels, Cindy M; Beckham, Jean C; Calhoun, Patrick S
2013-09-01
Alcohol screening with the 3-item alcohol use disorders identification test (AUDIT-C) has been implemented throughout the U.S. Veterans Health Administration. Validation of the AUDIT-C, however, has been conducted with samples of primarily older veterans. This study examined the diagnostic efficiency of the AUDIT-C in a younger cohort of veterans who served during Operation Enduring Freedom and/or Operation Iraqi Freedom (OEF/OIF). Veteran participants (N=1775) completed the alcohol use disorders identification test (AUDIT) and underwent the structured clinical interview for DSM-IV-TR for Axis I disorders (SCID) in research settings within four VA medical Centers. Areas under receiver operating characteristic curves (AUCs) measured the effiency of the full AUDIT and AUDIT-C in identifying SCID-based diagnoses of past year alcohol abuse or dependence. Both measures performed well in detecting alcohol use disorders. In the full sample, the AUDIT had a better AUC (.908; .881-.935) than the AUDIT-C (.859; .826-.893; p<.0001). It is notable that this same result was found among men but not women, perhaps due to reduced power. Diagnostic efficiency statistics for the AUDIT and AUDIT-C were consistent with results from older veteran samples. The diagnostic efficiency of both measures did not vary with race or age. Both the AUDIT and AUDIT-C appear to be valid instruments for identifying alcohol abuse or dependence among the most recent cohort of U.S. veterans with service during OEF/OIF within research settings. Published by Elsevier Ireland Ltd.
Effect Size as the Essential Statistic in Developing Methods for mTBI Diagnosis.
Gibson, Douglas Brandt
2015-01-01
The descriptive statistic known as "effect size" measures the distinguishability of two sets of data. Distingishability is at the core of diagnosis. This article is intended to point out the importance of effect size in the development of effective diagnostics for mild traumatic brain injury and to point out the applicability of the effect size statistic in comparing diagnostic efficiency across the main proposed TBI diagnostic methods: psychological, physiological, biochemical, and radiologic. Comparing diagnostic approaches is difficult because different researcher in different fields have different approaches to measuring efficacy. Converting diverse measures to effect sizes, as is done in meta-analysis, is a relatively easy way to make studies comparable.
ERIC Educational Resources Information Center
Waldman, Irwin D.; Lilienfeld, Scott O.
1991-01-01
Examined diagnostic efficiency of symptoms for experimentally diagnosed oppositional defiant disorder (OD) and attention-deficit hyperactivity disorder (ADHD) in 102 elementary-age boys. Findings from teacher ratings revealed that, on average, ADHD symptoms were as useful as OD symptoms as exclusion criteria for OD, whereas OD symptoms were nearly…
Bouzas, Lorena; Hermida, Jesús
2010-01-01
Objectives Therapeutic monitoring of sirolimus and everolimus is necessary in order to minimize adverse side-effects and to ensure effective immunosuppression. A sirolimus-dosing model using the concentration/dose ratio has been previously proposed for kidney transplant patients, and the aim of our study was the evaluation of this single model for the prediction of trough sirolimus and everolimus concentrations. Methods Trough steady-state sirolimus concentrations were determined in several blood samples from each of 7 kidney and 9 liver maintenance transplant recipients, and everolimus concentrations from 20 kidney, 17 liver, and 3 kidney/liver maintenance transplant recipients. Predicted sirolimus and everolimus concentrations (Css), corresponding to the doses (D), were calculated using the measured concentrations (Css0) and corresponding doses (D0) on starting the study: Css = (Css0)(D)/D0. Results The diagnostic efficiency of the predicting model for the correct classification as subtherapeutic, therapeutic, and supratherapeutic values with respect to the experimentally obtained concentrations was 91.3% for sirolimus and 81.4% for everolimus in the kidney transplant patients. In the liver transplant patients the efficiency was 69.2% for sirolimus and 72.6% for everolimus, and in the kidney/liver transplant recipients the efficiency for everolimus was 67.9%. Conclusions The model has an acceptable diagnostic efficiency (>80%) for the prediction of sirolimus and everolimus concentrations in kidney transplant recipients, but not in liver transplant recipients. However, considering the wide ranges found for the prediction error of sirolimus and everolimus concentrations, the clinical relevance of this dosing model is weak. PMID:19943816
Reuter, H; Burgess, L J; Schneider, J; Van Vuuren, W; Doubell, A F
2006-02-01
To establish the influence of human immunodeficiency virus (HIV) infection on the histopathological features of patients presenting with tuberculous pericarditis. A prospective study was carried out at Tygerberg Academic Hospital, South Africa; 36 patients with large pericardial effusions had open pericardial biopsies under general anaesthesia and were included in the study. Patients underwent pericardiocentesis, followed by daily intermittent catheter drainage; a comprehensive diagnostic work-up (including histopathology of the pericardial tissue) was also performed. Histological tuberculous pericarditis was diagnosed according to predetermined criteria. Tuberculous pericarditis was identified in 25 patients, five of whom were HIV+. The presence of granulomatous inflammation (with or without necrosis) and/or Ziehl-Neelsen positivity yielded the best test results (sensitivity 64%, specificity 100% and diagnostic efficiency 75%). Co-infection with HIV impacts on the histopathological features of pericardial tuberculosis and leads to a decrease in the sensitivity of the test. In areas which have a high prevalence of tuberculosis, the combination of a sensitive test such as adenosine deaminase, chest X-ray and clinical features has a higher diagnostic efficiency than pericardial biopsy in diagnosing tuberculous pericarditis.
Futatsuka, Makoto
2015-01-01
Large-scale food poisoning caused by methylmercury was identified in Minamata, Japan, in the 1950s (Minamata Disease). Although the diagnostic criteria for the disease was controversial and difficult during that time, we, the Kumamoto University Study Group, carried out a large-scale study to assess the clinical features in 1972-1973. The author tried to reassess the results of that study to appraise the diagnostic criteria established in 1977 on the basis of those results. A substantial number of residents in the exposed area exhibited neurologic signs, especially paresthesia of only the extremities, namely, the male residents of Minamata City showed a positive predictive value of 0.73 and a negative predictive value of 0.23. The relative risks of paresthesia only were 2.6 (2.0-3.3) and 1.2 (0.9-1.5), in Minamata and Goshonoura related to Ariake (control), respectively. At least until 1977, the diagnostic criteria remained valid, although it was inadequate. Nevertheless, presently, a follow-up study of the certified patients may lead to the development of efficient new diagnostic criteria.
NASA Astrophysics Data System (ADS)
Wright, David; Thyer, Mark; Westra, Seth
2015-04-01
Highly influential data points are those that have a disproportionately large impact on model performance, parameters and predictions. However, in current hydrological modelling practice the relative influence of individual data points on hydrological model calibration is not commonly evaluated. This presentation illustrates and evaluates several influence diagnostics tools that hydrological modellers can use to assess the relative influence of data. The feasibility and importance of including influence detection diagnostics as a standard tool in hydrological model calibration is discussed. Two classes of influence diagnostics are evaluated: (1) computationally demanding numerical "case deletion" diagnostics; and (2) computationally efficient analytical diagnostics, based on Cook's distance. These diagnostics are compared against hydrologically orientated diagnostics that describe changes in the model parameters (measured through the Mahalanobis distance), performance (objective function displacement) and predictions (mean and maximum streamflow). These influence diagnostics are applied to two case studies: a stage/discharge rating curve model, and a conceptual rainfall-runoff model (GR4J). Removing a single data point from the calibration resulted in differences to mean flow predictions of up to 6% for the rating curve model, and differences to mean and maximum flow predictions of up to 10% and 17%, respectively, for the hydrological model. When using the Nash-Sutcliffe efficiency in calibration, the computationally cheaper Cook's distance metrics produce similar results to the case-deletion metrics at a fraction of the computational cost. However, Cooks distance is adapted from linear regression with inherit assumptions on the data and is therefore less flexible than case deletion. Influential point detection diagnostics show great potential to improve current hydrological modelling practices by identifying highly influential data points. The findings of this study establish the feasibility and importance of including influential point detection diagnostics as a standard tool in hydrological model calibration. They provide the hydrologist with important information on whether model calibration is susceptible to a small number of highly influent data points. This enables the hydrologist to make a more informed decision of whether to (1) remove/retain the calibration data; (2) adjust the calibration strategy and/or hydrological model to reduce the susceptibility of model predictions to a small number of influential observations.
Diagnostic Efficiency of easyCBM[R] Math: Washington State. Technical Report #1008
ERIC Educational Resources Information Center
Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2010-01-01
easyCBM[R] is an online benchmark and progress monitoring assessment system designed for use within a response to intervention framework. Educators using easyCBM[R] are often interested in using the results to predict students' state test performance. In the following technical document, we report diagnostic efficiency statistics using a sample…
Sharma, Aseem; Chatterjee, Arindam; Goyal, Manu; Parsons, Matthew S; Bartel, Seth
2015-04-01
Targeting redundancy within MRI can improve its cost-effective utilization. We sought to quantify potential redundancy in our brain MRI protocols. In this retrospective review, we aggregated 207 consecutive adults who underwent brain MRI and reviewed their medical records to document clinical indication, core diagnostic information provided by MRI, and its clinical impact. Contributory imaging abnormalities constituted positive core diagnostic information whereas absence of imaging abnormalities constituted negative core diagnostic information. The senior author selected core sequences deemed sufficient for extraction of core diagnostic information. For validating core sequences selection, four readers assessed the relative ease of extracting core diagnostic information from the core sequences. Potential redundancy was calculated by comparing the average number of core sequences to the average number of sequences obtained. Scanning had been performed using 9.4±2.8 sequences over 37.3±12.3 minutes. Core diagnostic information was deemed extractable from 2.1±1.1 core sequences, with an assumed scanning time of 8.6±4.8 minutes, reflecting a potential redundancy of 74.5%±19.1%. Potential redundancy was least in scans obtained for treatment planning (14.9%±25.7%) and highest in scans obtained for follow-up of benign diseases (81.4%±12.6%). In 97.4% of cases, all four readers considered core diagnostic information to be either easily extractable from core sequences or the ease to be equivalent to that from the entire study. With only one MRI lacking clinical impact (0.48%), overutilization did not seem to contribute to potential redundancy. High potential redundancy that can be targeted for more efficient scanner utilization exists in brain MRI protocols.
Diagnostic value of CRP and Lp(a) in coronary heart disease.
Erbağci, Ayşe Binnur; Tarakçioğlu, Mehmet; Aksoy, Mehmet; Kocabaş, Ramazan; Nacak, Muradiye; Aynacioğlu, A Sükrü; Sivrikoz, Cumhur
2002-06-01
Increased lipoprotein (a) [Lp(a)] concentration was reported to be an independent risk factor for coronary heart disease (CHD). Recent epidemiological studies affirmed the value of C-reactive protein (CRP) as the strongest, univariate predictor of the cardiovascular events. We decided to establish cut-off levels providing maximum diagnostic efficiency for CHD. In this study we measured CRP and Lp(a) concentrations in patients with angiographically demonstrated CHD (group A, n: 120), patients without any angiographically demonstrable lesion (group B, n: 62) and a group of healthy subjects (group C, n: 41). Data were evaluated correcting for lipid and lipoprotein concentrations, diabetes mellitus, hypertension, smoking, age, and body mass index in men and women. ROC curve based cut-off values (comparing group A versus groups B and C) and associated diagnostic performances of the assays were evaluated. Significant increases were noted in serum CRP concentrations in men and women, in groups A vs. B,A vs. C, B vs. C. Lp(a) concentrations were not different among groups in men but were higher in group A vs. B and C in women. Optimal cut-off levels for CRP in women and men were found as 2.1 and 3.0 mg/l with the diagnostic values of 0.792 and 0.770, respectively. For Lp(a) optimal cut-off levels were found as 22.6 and 9.8 mg/dl with the diagnostic values of 0.612 and 0.596 in women and men, respectively. The CRP level is quite efficient for separation of patients from controls. Therefore keeping in mind the lack of specificity, the CRP level may be a useful tool in the diagnosis of coronary heart disease. However, the Lp(a) level is not efficient enough to support the use of Lp(a) measurement for management of coronary heart disease.
ERIC Educational Resources Information Center
Villabo, Marianne; Gere, Martina; Torgersen, Svenn; March, John S.; Kendall, Philip C.
2012-01-01
The objective of this study is to evaluate the psychometrics and clinical efficiency of the Multidimensional Anxiety Scale for Children (MASC), which measures physical symptoms, harm avoidance, social anxiety, and separation/panic. Using a sample of 190 treatment-seeking Norwegian youth (aged 7-13 years, M[subscript age] = 10.3 years, 62.1% male),…
Collinson, Paul; Goodacre, Steve; Gaze, David; Gray, Alasdair
2012-02-01
To assess the impact of triple marker testing on patient management and the diagnostic efficiencies of different biomarker strategies examined. A prospective randomised trial of triple marker testing by point-of-care testing (POCT); the Randomised Assessment of Panel Assay of Cardiac markers (RATPAC) study. Six emergency departments. Low-risk patients presenting with chest pain to diagnostic assessment with a cardiac panel measured by POCT or to diagnosis when biomarker measurement was based on central laboratory testing. Interventions 1125 patients were randomly assigned to POCT measurement of the triple marker panel of cardiac troponin I (cTnI), myoglobin and the MB isoenzyme of creatine kinase (CK-MB) on admission and 90 min from admission. Myocardial infarction (MI) was defined by the universal definition of MI. The following diagnostic strategies were compared by receiver operator characteristic (ROC) curve analysis and comparison of area under the curve (AUC): individual marker values, change (Δ) in CK-MB and myoglobin and the combination of presentation or 90 min value plus Δ value. Admission sample measurement of cTnI was the most diagnostically efficient AUC 0.96 (0.93-0.98) with areas under the ROC curve statistically significantly greater than CK-MB 0.85 (0.80-0.90) and myoglobin 0.75 (0.68-0.81). At 90 min cTnI measurement had the highest AUC 0.95 (0.87-1.00) but was statistically significantly different only from Δmyoglobin and ΔCK-MB. Measurement of cTnI alone is sufficient for diagnosis. Measurement of a marker panel does not facilitate diagnosis.
ERIC Educational Resources Information Center
Hsu, Pi-Shan; Chang, Te-Jeng; Wu, Ming-Hsiung
2009-01-01
The level of learners' expertise has been used as a metric and diagnostic mechanism of instruction. This metric influences mental effort directly according to the applications of cognitive load theory. Cognitive efficiency, an optimal measurement technique of expertise, was developed by Kalyuga and Sweller to replace instructional efficiency in…
NASA Astrophysics Data System (ADS)
Sokolov, Vladimir V.; Filonenko, E. V.; Telegina, L. V.; Boulgakova, N. N.; Smirnov, V. V.
2002-11-01
The results of comparative studies of autofluorescence and 5-ALA-induced fluorescence of protoporphyrin IX, used in the diagnostics of early cancer of larynx and bronchi, are presented. The autofluorescence and 5-ALA-induced fluorescence images of larynx and bronchial tissues are analysed during the endoscopic study. The method of local spectrophotometry is used to verify findings obtained from fluorescence images. It is shown that such a combined approach can be efficiently used to improve the diagnostics of precancer and early cancer, to detect a primary multiple tumours, as well as for the diagnostics of a residual tumour or an early recurrence after the endoscopic, surgery or X-ray treatment. The developed approach allows one to minimise the number of false-positive results and to reduce the number of biopsies, which are commonly used in the white-light bronchoscopy search for occult cancerous loci.
Martín, V; Domínguez, A; Alcaide, J
1997-01-01
In spanish prisons, tuberculosis is a serious problem of public health and health authorities don't take it seriously. To prove the efficiency of pulmonary tuberculosis case-finding on arrival at prison in order to get location resources in this activity. Cost-benefit analysis of a case-finding program compared with to wait for diagnostic to illness. The sensitivity of test was fixed in 80% and the specificity in 99.99%. The cost was based on market prices. Sensitivity analysis was done in every variables as well as tridimensional analysis in those one of more influence. The case-finding was efficient on prevalences of tuberculosis over 5 per mil. Its efficiency was hardly affected by discount social rates or the sensitivity of diagnostic tests. The prevalence of illness, the cost of diagnostic activities as well as the success of treatment and the specificity of diagnostic tests used had as influence on the efficiency model. The tridimensional analysis proved that the case-finding of pulmonary tuberculosis has efficiency on low prevalences (1 per thousand), provided the number of people cured is a 5% higher than the alternative one and the costs of case-finding less than 1,000 pesetas per subject. The case-finding pulmonary tuberculosis on arrival at prisons is of high efficiency. In a cost-opportunity situation (location of available resources, penitentiary and extrapenitentiary) the program is very efficacious taking into account the fact of higher prevalence of pulmonary tuberculosis in this people.
NASA Astrophysics Data System (ADS)
Shalkov, Anton; Mamaeva, Mariya
2017-11-01
The article considers the questions of application of nondestructive methods control of reducers of conveyor belts as a means of transport. Particular attention is paid to such types of diagnostics of technical condition as thermal control and analysis of the state of lubricants. The urgency of carrying out types of nondestructive testing presented in the article is determined by the increase of energy efficiency of transport systems of coal and mining enterprises, in particular, reducers of belt conveyors. Periodic in-depth spectral-emission diagnostics and monitoring of a temperature mode of operation oil in the operation of the control equipment and its technical condition and prevent the MTBF allows the monitoring of the actual technical condition of the gearbox of a belt conveyor. In turn, the thermal imaging diagnostics reveals defects at the earliest stage of their formation and development, which allows planning the volumes and terms of equipment repair. Presents diagnostics of the technical condition will allow monitoring in time the technical condition of the equipment and avoiding its premature failure. Thereby it will increase the energy efficiency of both the transport system and the enterprise as a whole, and also avoid unreasonable increases in operating and maintenance costs.
Infrared measurements of a scramjet exhaust. [to determine combustion efficiency
NASA Technical Reports Server (NTRS)
Reed, R. A.; Slack, M. W.
1980-01-01
Diagnostic 2 - 5 mm infrared spectra of a hydrogen burning scramjet exhaust were measured with an interferometer spectrometer. Exhaust gas temperatures and water vapor partial pressures were determined from the observed intensity and spectral profile of the H2O 2.7 mm infrared emission band. Overall engine combustion efficiencies were derived by combining these measurements with the known engine operating conditions. Efficiencies fall (70 - 50 percent) as fuel equivalence ratios rise (0.4 - 1.0). Data analysis techniques and sensitivity studies are also presented.
Canestaro, William J; Pritchard, Daryl E; Garrison, Louis P; Dubois, Robert; Veenstra, David L
2015-08-01
Companion diagnostic tests (CDTs) have emerged as a vital technology in the effective use of an increasing number of targeted drug therapies. Although CDTs can offer a multitude of potential benefits, assessing their value within a health technology appraisal process can be challenging because of a complex array of factors that influence clinical and economic outcomes. To develop a user-friendly tool to assist managed care and other health care decision makers in screening companion tests and determining whether an intensive technology review is necessary and, if so, where the review should be focused to improve efficiency. First, we conducted a systematic literature review of CDT cost-effectiveness studies to identify value drivers. Second, we conducted key informant interviews with a diverse group of stakeholders to elicit feedback and solicit any additional value drivers and identify desirable attributes for an evidence review tool. A draft tool was developed based on this information that captured value drivers, usability features, and had a particular focus on practical use by nonexperts. Finally, the tool was pilot tested with test developers and managed care evidence evaluators to assess face-validity and usability. The tool was also evaluated using several diverse examples of existing companion diagnostics and refined accordingly. We identified 65 cost-effectiveness studies of companion diagnostic technologies. The following factors were most commonly identified as value drivers from our literature review: clinical validity of testing; efficacy, safety, and cost of baseline and alternative treatments; cost and mortality of health states; and biomarker prevalence and testing cost. Stakeholders identified the following additional factors that they believed influenced the overall value of a companion test: regulatory status, actionability, utility, and market penetration. These factors were used to maximize the efficiency of the evidence review process. Stakeholders also stated that a tool should be easy to use and time efficient. Cognitive interviews with stakeholders led to minor changes in the draft tool to improve usability and relevance. The final tool consisted of 4 sections: (1) eligibility for review (2 questions), (2) prioritization of review (3 questions), (3) clinical review (3 questions), and (4) economic review (5 questions). Although the evaluation of CDTs can be challenging because of limited evidence and the added complexity of incorporating a diagnostic test into drug treatment decisions, using a pragmatic tool to identify tests that do not need extensive evaluation may improve the efficiency and effectiveness of CDT value assessments.
An evidence-based diagnostic classification system for low back pain
Vining, Robert; Potocki, Eric; Seidman, Michael; Morgenthal, A. Paige
2013-01-01
Introduction: While clinicians generally accept that musculoskeletal low back pain (LBP) can arise from specific tissues, it remains difficult to confirm specific sources. Methods: Based on evidence supported by diagnostic utility studies, doctors of chiropractic functioning as members of a research clinic created a diagnostic classification system, corresponding exam and checklist based on strength of evidence, and in-office efficiency. Results: The diagnostic classification system contains one screening category, two pain categories: Nociceptive, Neuropathic, one functional evaluation category, and one category for unknown or poorly defined diagnoses. Nociceptive and neuropathic pain categories are each divided into 4 subcategories. Conclusion: This article describes and discusses the strength of evidence surrounding diagnostic categories for an in-office, clinical exam and checklist tool for LBP diagnosis. The use of a standardized tool for diagnosing low back pain in clinical and research settings is encouraged. PMID:23997245
Timely Diagnostic Feedback for Database Concept Learning
ERIC Educational Resources Information Center
Lin, Jian-Wei; Lai, Yuan-Cheng; Chuang, Yuh-Shy
2013-01-01
To efficiently learn database concepts, this work adopts association rules to provide diagnostic feedback for drawing an Entity-Relationship Diagram (ERD). Using association rules and Asynchronous JavaScript and XML (AJAX) techniques, this work implements a novel Web-based Timely Diagnosis System (WTDS), which provides timely diagnostic feedback…
Mishlanov, V Yu; Katkova, A V; Dugina, A A; Kuznetzova, V D; Tepanyan, A T; Zhygulev, A N
The aim of the study was to estimate clinical efficiency of the interactive automatic program of digestive system diseases diagnostics "Electronic policlinic". Material was presented by 22 patients with different gastroenterological diseases (duodenal ulcer, chronical gastritis, chronical pancreatitis) and the comparative group consisted of 20 healthy people. The plan of the research included the interactive questionnaire using diagnostic module digestive system diseases of the digestive system of the automated program "Electronic policlinic" (Certificate No. 2012614202 from 12.05.12) posted on the Internet (http://klinikcity.ru). For the purpose of verification of diagnosis patients underwent fibrogastroduodenoscopy, ultrasound examination of abdominal cavity organs, CT scan, sigmoidoscopy, colonoscopy, barium enema. As the result of the study there were showed that interactive automated system was able to reveal 85,7% of patients with chronical gastritis, duodenal ulcer and chronical pancreatitis and 75% of patients with colonopathy. The specify of diagnostic procedure was 80% in the first case and 100% in the second. Prevalence of digestive system diseases basic symptoms was studied too. The conclusion of the study demonstrated interactive questionnaire good ability in preliminary digestive problem patient examination procedure for individual diagnostic plan making.
Instrument for evaluation of sedentary lifestyle in patients with high blood pressure.
Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; de Araujo, Thelma Leite; Guedes, Nirla Gomes; Martins, Larissa Castelo Guedes; Teixeira, Iane Ximenes
2015-01-01
this article describes the diagnostic accuracy of the International Physical Activity Questionnaire to identify the nursing diagnosis of sedentary lifestyle. a diagnostic accuracy study was developed with 240 individuals with established high blood pressure. The analysis of diagnostic accuracy was based on measures of sensitivity, specificity, predictive values, likelihood ratios, efficiency, diagnostic odds ratio, Youden index, and area under the receiver-operating characteristic curve. statistical differences between genders were observed for activities of moderate intensity and for total physical activity. Age was negatively correlated with activities of moderate intensity and total physical activity. the analysis of area under the receiver-operating characteristic curve for moderate intensity activities, walking, and total physical activity showed that the International Physical Activity Questionnaire present moderate capacity to correctly classify individuals with and without sedentary lifestyle.
Yokota, Hajime; Goto, Mariko; Bamba, Chisa; Kiba, Maki; Yamada, Kei
2017-05-01
To assess whether alterations in the type of duty assignment system can affect the reading efficiency and stress level of diagnostic radiologists. Fourteen board-certified diagnostic radiologists were enrolled. We investigated three different reading systems for 1 week each. System 1 is our default, in which there are no assigned duties and everyone finishes when all cases are done. In system 2, two late shift readers are assigned every day, and, after everyone else leaves at a fixed time (5:30 p.m.), they take all remaining cases until they are finished. In system 3, a dedicated single reader is assigned to finish 30 cases, and everyone else will read all remaining cases. The total time required for reading and the number of cases read were recorded. In addition, participants completed two questionnaires regarding work-related stress. There was a trend toward shorter finishing time in system 2 and 3 compared to system 1 (P = 0.072 and 0.012). In terms of working stress, the subjective burden was lighter when systems 2 or 3 were employed. Minor modification of the duty assignment system has the potential to improve working efficiency and may reduce the work-related stress of diagnostic radiologists.
Atomic and molecular gas phase spectrometry
NASA Astrophysics Data System (ADS)
Winefordner, J. D.
1985-10-01
The major goals of this research have been to develop diagnostical spectroscopic methods for measuring spatial/temporal temperatures and species of combustion flames and plasmas and to develop sensitive, selective, precise, reliable, rapid spectrometric methods of trace analysis of elements present in jet engine lubricating oils, metallurgical samples, and engine exhausts. The diagnostical approaches have been based upon the measurement of metal probes introduced into the flame or plasmas and the measurement of OH in flames. The measurement approaches have involved the use of laser-excited fluorescence, saturated absorption, polarization, and linear absorption. The spatial resolution in most studies is less than 1 cu mm and the temporal resolution is less than 10 ns with the use of pulsed lasers. Single pulse temperature and species measurements have also been carried out. Other diagnostical studies have involved the measurement of collisional redistribution of radiatively excited levels of Na and Tl in acetylene/02/Ar flames and the measurement of lifetimes and quantum efficiencies of atoms and ions in the inductively coupled plasmas, ICP. The latter studies indicate that the high electron number densities in ICPs are not efficient quenchers of excited atoms/ions. Temperatures of microwave atmospheric plasmas produced capacitatively and cool metastable N2 discharge produced by a dielectric discharge have also been measured.
Koçyiğit Deveci, Emel; Ocak, Meltem; Bozkurt, Murat Fani; Türker, Selcan; Kabasakal, Levent; Uğur, Omer
2013-12-01
The aim of this study was to assess the diagnostic efficiency of (99m)Tc-EDDA/HYNIC-Octreotate in comparison with (111)Inpentetrotide scintigraphy in the detection of neuroendocrine tumors. This study also evaluates the impact of SPECT-CT hybrid imaging on somatostatin receptor scintigraphy (SRS) interpretation and clinical management of these tumors. Fourteen patients were included in the study. All patients underwent a whole body and SPECT-CT imaging with both (99m)Tc- EDDA/HYNIC-octreotate and (111)In-pentetrotide. Images were evaluated both visually and semiquantitatively. On patient basis, the diagnostic results of both studies were similar. The number of lesions detected by (99m)Tc- EDDA/HYNICOctreotate were higher than the number of lesions detected by (111)In-pentetrotide however the difference was not significant (40/43( 93%), 36/43 (83%) p=0.109). Semiquantitative analysis showed higher tumor/organ count ratios for both whole-body and SPECT (99m)Tc- EDDA/HYNIC-Octreotate scans. The results of this study suggested that, (99m)Tc- EDDA/HYNIC-Octreotate may be a better alternative to (111)In- pentetrotide due to high image quality and lower radiation dose. SPECT/CT is a valuable tool for the assessment of neuroendocrine tumors by providing the precise anatomic localization of scintigraphic findings thus improving lesion detectability and characterization. None declared.
NASA Astrophysics Data System (ADS)
Gajek, Andrzej
2016-09-01
The article presents diagnostics monitor for control of the efficiency of brakes in various road conditions in cars equipped with pressure sensor in brake (ESP) system. Now the brake efficiency of the vehicles is estimated periodically in the stand conditions on the base of brake forces measurement or in the road conditions on the base of the brake deceleration. The presented method allows to complete the stand - periodical tests of the brakes by current on board diagnostics system OBD for brakes. First part of the article presents theoretical dependences between deceleration of the vehicle and brake pressure. The influence of the vehicle mass, initial speed of braking, temperature of brakes, aerodynamic drag, rolling resistance, engine resistance, state of the road surface, angle of the road sloping on the deceleration have been analysed. The manner of the appointed of these parameters has been analysed. The results of the initial investigation have been presented. At the end of the article the strategy of the estimation and signalization of the irregular value of the deceleration are presented.
Assisting Adult Higher Education via Personal Computer: Technology and Distance Education.
ERIC Educational Resources Information Center
Spradley, Evelyn
1993-01-01
Thomas Edison State College (New Jersey) has developed a computer-assisted distance learning system to make undergraduate study more accessible, efficient, and effective for nontraditional students. The three main components: an infrastructure to provide varied technical services; an independent study course system; and diagnostic, online pretests…
The rapid evolution of molecular genetic diagnostics in neuromuscular diseases.
Volk, Alexander E; Kubisch, Christian
2017-10-01
The development of massively parallel sequencing (MPS) has revolutionized molecular genetic diagnostics in monogenic disorders. The present review gives a brief overview of different MPS-based approaches used in clinical diagnostics of neuromuscular disorders (NMDs) and highlights their advantages and limitations. MPS-based approaches like gene panel sequencing, (whole) exome sequencing, (whole) genome sequencing, and RNA sequencing have been used to identify the genetic cause in NMDs. Although gene panel sequencing has evolved as a standard test for heterogeneous diseases, it is still debated, mainly because of financial issues and unsolved problems of variant interpretation, whether genome sequencing (and to a lesser extent also exome sequencing) of single patients can already be regarded as routine diagnostics. However, it has been shown that the inclusion of parents and additional family members often leads to a substantial increase in the diagnostic yield in exome-wide/genome-wide MPS approaches. In addition, MPS-based RNA sequencing just enters the research and diagnostic scene. Next-generation sequencing increasingly enables the detection of the genetic cause in highly heterogeneous diseases like NMDs in an efficient and affordable way. Gene panel sequencing and family-based exome sequencing have been proven as potent and cost-efficient diagnostic tools. Although clinical validation and interpretation of genome sequencing is still challenging, diagnostic RNA sequencing represents a promising tool to bypass some hurdles of diagnostics using genomic DNA.
Madison, Matthew J; Bradshaw, Laine P
2015-06-01
Diagnostic classification models are psychometric models that aim to classify examinees according to their mastery or non-mastery of specified latent characteristics. These models are well-suited for providing diagnostic feedback on educational assessments because of their practical efficiency and increased reliability when compared with other multidimensional measurement models. A priori specifications of which latent characteristics or attributes are measured by each item are a core element of the diagnostic assessment design. This item-attribute alignment, expressed in a Q-matrix, precedes and supports any inference resulting from the application of the diagnostic classification model. This study investigates the effects of Q-matrix design on classification accuracy for the log-linear cognitive diagnosis model. Results indicate that classification accuracy, reliability, and convergence rates improve when the Q-matrix contains isolated information from each measured attribute.
Mills, Anne M; Gradecki, Sarah E; Horton, Bethany J; Blackwell, Rebecca; Moskaluk, Christopher A; Mandell, James W; Mills, Stacey E; Cathro, Helen P
2018-01-01
Prior work has shown that digital images and microscopic slides can be interpreted with comparable diagnostic accuracy. Although accuracy has been well-validated, the interpretative time for digital images has scarcely been studied and concerns about efficiency remain a major barrier to adoption. We investigated the efficiency of digital pathology when compared with glass slide interpretation in the diagnosis of surgical pathology biopsy and resection specimens. Slides were pulled from 510 surgical pathology cases from 5 organ systems (gastrointestinal, gynecologic, liver, bladder, and brain). Original diagnoses were independently confirmed by 2 validating pathologists. Diagnostic slides were scanned using the Philips IntelliSite Pathology Solution. Each case was assessed independently on digital and optical by 3 reading pathologists, with a ≥6 week washout period between modalities. Reading pathologists recorded assessment times for each modality; digital times included time to load the case. Diagnostic accuracy was determined based on whether a rendered diagnosis differed significantly from the original diagnosis. Statistical analysis was performed to assess for differences in interpretative times across modalities. All 3 reading pathologists showed comparable diagnostic accuracy across optical and digital modalities (mean major discordance rates with original diagnosis: 4.8% vs. 4.4%, respectively). Mean assessment times ranged from 1.2 to 9.1 seconds slower on digital versus optical. The slowest reader showed a significant learning effect during the course of the study so that digital assessment times decreased over time and were comparable with optical times by the end of the series. Organ site and specimen type did not significantly influence differences in interpretative times. In summary, digital image reading times compare favorably relative to glass slides across a variety of organ systems and specimen types. Mean increase in assessment time is 4 seconds/case. This time can be minimized with experience and may be further balanced by the improved ease of electronic chart access allowed by digital slide viewing, as well as quantitative assessments which can be expedited on digital images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sokolov, Vladimir V; Filonenko, E V; Telegina, L V
2002-11-30
The results of comparative studies of autofluorescence and 5-ALA-induced fluorescence of protoporphyrin IX, used in the diagnostics of early cancer of larynx and bronchi, are presented. The autofluorescence and 5-ALA-induced fluorescence images of larynx and bronchial tissues are analysed during the endoscopic study. The method of local spectrophotometry is used to verify findings obtained from fluorescence images. It is shown that such a combined approach can be efficiently used to improve the diagnostics of precancer and early cancer, to detect a primary multiple tumours, as well as for the diagnostics of a residual tumour or an early recurrence after themore » endoscopic, surgery or X-ray treatment. The developed approach allows one to minimise the number of false-positive results and to reduce the number of biopsies, which are commonly used in the white-light bronchoscopy search for occult cancerous loci. (laser biology and medicine)« less
Welk, Blayne; Liu, Kuan; Al-Jaishi, Ahmed; McArthur, Eric; Jain, Arsh K; Ordon, Michael
2016-01-01
Health information exchange systems can link the results of diagnostic imaging tests across hospitals and geographic areas. One of the potential benefits of these systems is a reduction in imaging studies ordered by physicians who do not know about or have access to the previous imaging results. We used administrative data from Ontario, Canada (from the year 2013), to measure how frequently the same cross-sectional imaging study is repeated in a patient. Overall, 12.8% of the specified imaging tests were repeated within 90 days. An area of Southwestern Ontario with a health information exchange system for diagnostic imaging tests had a 13% lower rate of repeat cross-sectional imaging compared with the rest of the province (11.2 vs 12.8%, p < 0.01). The use of linked radiology systems may be able to reduce the number of repeated imaging tests and improve patient safety and hospital efficiency.
Efficient fault diagnosis of helicopter gearboxes
NASA Technical Reports Server (NTRS)
Chin, H.; Danai, K.; Lewicki, D. G.
1993-01-01
Application of a diagnostic system to a helicopter gearbox is presented. The diagnostic system is a nonparametric pattern classifier that uses a multi-valued influence matrix (MVIM) as its diagnostic model and benefits from a fast learning algorithm that enables it to estimate its diagnostic model from a small number of measurement-fault data. To test this diagnostic system, vibration measurements were collected from a helicopter gearbox test stand during accelerated fatigue tests and at various fault instances. The diagnostic results indicate that the MVIM system can accurately detect and diagnose various gearbox faults so long as they are included in training.
Loś-Spychalska, T
1997-01-01
A growing incidence of the voice organ occupational diseases has recently become one of major health problems. There is a need to objective diagnostic examinations performed in teachers who apply for occupational disease certification. The aim of our study was to assess the feasibility of larynx vocal efficiency test during noise load in diagnosis of the voice organ occupational diseases in teachers.
An Artificial Intelligence Approach for Gears Diagnostics in AUVs
Marichal, Graciliano Nicolás; Del Castillo, María Lourdes; López, Jesús; Padrón, Isidro; Artés, Mariano
2016-01-01
In this paper, an intelligent scheme for detecting incipient defects in spur gears is presented. In fact, the study has been undertaken to determine these defects in a single propeller system of a small-sized unmanned helicopter. It is important to remark that although the study focused on this particular system, the obtained results could be extended to other systems known as AUVs (Autonomous Unmanned Vehicles), where the usage of polymer gears in the vehicle transmission is frequent. Few studies have been carried out on these kinds of gears. In this paper, an experimental platform has been adapted for the study and several samples have been prepared. Moreover, several vibration signals have been measured and their time-frequency characteristics have been taken as inputs to the diagnostic system. In fact, a diagnostic system based on an artificial intelligence strategy has been devised. Furthermore, techniques based on several paradigms of the Artificial Intelligence (Neural Networks, Fuzzy systems and Genetic Algorithms) have been applied altogether in order to design an efficient fault diagnostic system. A hybrid Genetic Neuro-Fuzzy system has been developed, where it is possible, at the final stage of the learning process, to express the fault diagnostic system as a set of fuzzy rules. Several trials have been carried out and satisfactory results have been achieved. PMID:27077868
An Artificial Intelligence Approach for Gears Diagnostics in AUVs.
Marichal, Graciliano Nicolás; Del Castillo, María Lourdes; López, Jesús; Padrón, Isidro; Artés, Mariano
2016-04-12
In this paper, an intelligent scheme for detecting incipient defects in spur gears is presented. In fact, the study has been undertaken to determine these defects in a single propeller system of a small-sized unmanned helicopter. It is important to remark that although the study focused on this particular system, the obtained results could be extended to other systems known as AUVs (Autonomous Unmanned Vehicles), where the usage of polymer gears in the vehicle transmission is frequent. Few studies have been carried out on these kinds of gears. In this paper, an experimental platform has been adapted for the study and several samples have been prepared. Moreover, several vibration signals have been measured and their time-frequency characteristics have been taken as inputs to the diagnostic system. In fact, a diagnostic system based on an artificial intelligence strategy has been devised. Furthermore, techniques based on several paradigms of the Artificial Intelligence (Neural Networks, Fuzzy systems and Genetic Algorithms) have been applied altogether in order to design an efficient fault diagnostic system. A hybrid Genetic Neuro-Fuzzy system has been developed, where it is possible, at the final stage of the learning process, to express the fault diagnostic system as a set of fuzzy rules. Several trials have been carried out and satisfactory results have been achieved.
Fritz, Jan; Henes, Jörg C; Thomas, Christoph; Clasen, Stephan; Fenchel, Michael; Claussen, Claus D; Lewin, Jonathan S; Pereira, Philippe L
2008-12-01
The objective of our study was to prospectively test the hypothesis that combined diagnostic and interventional MRI of the sacroiliac joints can be performed efficiently and effectively. Over a 12-month period, 60 patients (32 women and 28 men; median age, 28 years; age range, 18-49 years) with chronic lower back pain suspected to originate from the sacroiliac joints were enrolled in the study. Based on diagnostic MRI findings, MR fluoroscopy-guided sacroiliac joint injections were performed in 57 (95%) patients. Diagnostic injections (35, 58.3%) were performed if nonspecific or degenerative MRI findings were present. Therapeutic injections (22, 36.7%) were performed in patients with inflammatory arthropathy. In three (5%) patients, no injections were performed. Technical effectiveness was assessed by analyzing, first, the rate of intraarticular injection; second, the time required for the procedure; third, image quality; and, fourth, occurrence of complications and clinical outcome by analyzing pain intensity changes and volume and signal intensity of sacroiliac inflammatory changes. The rate of intraarticular injection was 90.4% (103/114). The mean length of time for the procedure was 50 minutes (range, 34-103 minutes), with exponential shortening over time (p < or = 0.001). The contrast-to-noise ratios of the needle and tissues were sufficiently different for excellent delineation of the needle. No complications occurred. Diagnostic injections identified the sacroiliac joints as generating significant pain in 46.9% (15/32) of the patients. Three months after therapeutic injections, pain intensity had decreased by 62.5% (p < or = 0.001) and the volume and relative signal intensity of inflammatory changes had decreased by 37.5% (p = 0.003) and 47.6% (p < or = 0.001), respectively. We accept the hypothesis that combined diagnostic and interventional MRI of the sacroiliac joints can be performed efficiently and effectively for comprehensive diagnosis and therapy of lower back pain originating from the sacroiliac joints.
Nazerian, Peiman; Mueller, Christian; Soeiro, Alexandre de Matos; Leidel, Bernd A; Salvadeo, Sibilla Anna Teresa; Giachino, Francesca; Vanni, Simone; Grimm, Karin; Oliveira, Múcio Tavares; Pivetta, Emanuele; Lupia, Enrico; Grifoni, Stefano; Morello, Fulvio
2018-01-16
Acute aortic syndromes (AASs) are rare and severe cardiovascular emergencies with unspecific symptoms. For AASs, both misdiagnosis and overtesting are key concerns, and standardized diagnostic strategies may help physicians to balance these risks. D-dimer (DD) is highly sensitive for AAS but is inadequate as a stand-alone test. Integration of pretest probability assessment with DD testing is feasible, but the safety and efficiency of such a diagnostic strategy are currently unknown. In a multicenter prospective observational study involving 6 hospitals in 4 countries from 2014 to 2016, consecutive outpatients were eligible if they had ≥1 of the following: chest/abdominal/back pain, syncope, perfusion deficit, and if AAS was in the differential diagnosis. The tool for pretest probability assessment was the aortic dissection detection risk score (ADD-RS, 0-3) per current guidelines. DD was considered negative (DD-) if <500 ng/mL. Final case adjudication was based on conclusive diagnostic imaging, autopsy, surgery, or 14-day follow-up. Outcomes were the failure rate and efficiency of a diagnostic strategy for ruling out AAS in patients with ADD-RS=0/DD- or ADD-RS ≤1/DD-. A total of 1850 patients were analyzed. Of these, 438 patients (24%) had ADD-RS=0, 1071 patients (58%) had ADD-RS=1, and 341 patients (18%) had ADD-RS >1. Two hundred forty-one patients (13%) had AAS: 125 had type A aortic dissection, 53 had type B aortic dissection, 35 had intramural aortic hematoma, 18 had aortic rupture, and 10 had penetrating aortic ulcer. A positive DD test result had an overall sensitivity of 96.7% (95% confidence interval [CI], 93.6-98.6) and a specificity of 64% (95% CI, 61.6-66.4) for the diagnosis of AAS; 8 patients with AAS had DD-. In 294 patients with ADD-RS=0/DD-, 1 case of AAS was observed. This yielded a failure rate of 0.3% (95% CI, 0.1-1.9) and an efficiency of 15.9% (95% CI, 14.3-17.6) for the ADD-RS=0/DD- strategy. In 924 patients with ADD-RS ≤1/DD-, 3 cases of AAS were observed. This yielded a failure rate of 0.3% (95% CI, 0.1-1) and an efficiency of 49.9% (95% CI, 47.7-52.2) for the ADD-RS ≤1/DD- strategy. Integration of ADD-RS (either ADD-RS=0 or ADD-RS ≤1) with DD may be considered to standardize diagnostic rule out of AAS. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02086136. © 2017 American Heart Association, Inc.
Diagnostic value of KLK6 as an ovarian cancer biomarker: A meta-analysis.
Yang, Fan; Hu, Zhi-DE; Chen, Yingjian; Hu, Cheng-Jin
2016-06-01
Kallikrein-related peptidase 6 (KLK6) is a new potential serum biomarker of ovarian cancer. The aim of the present study was to assess the diagnostic value of KLK6 systematically for ovarian cancer. All the selected studies regarding the changes of KLK6 in ovarian cancer were published prior to April 2015. Five studies involving 485 patients with ovarian cancer, 420 benign cysts and 245 healthy controls met the inclusion criteria. The value of sensitivity, specificity, positive-likelihood ratio (LR+), negative-likelihood ratio (LR-) and area under the receiver operating characteristic curve (ROC) were obtained. All these indices were used to evaluate the diagnostic value of KLK6 for ovarian cancer. The values of sensitivity, specificity, LR+ and LR- (95% confidence interval) of KLK6 were 0.50 (0.47-0.54), 0.91 (0.89-0.93), 7.20 (3.34-15.52) and 0.51 (0.43-0.62), respectively. The area under the summary ROC of KLK6 was 0.86. The index of Q* was 0.79. In conclusion, KLK6 showed high specificity for the diagnosis of ovarian cancer. It can improve the diagnostic accuracy of cancer antigen 125 (CA125). A combined panel of CA125 and KL K6 shows a high diagnostic efficiency for advanced ovarian cancer. Owing to the small number of studies and lack of samples, additional studies meeting the inclusion criteria are required to further analyze the diagnostic value of KLK6 for ovarian cancer.
Sex-specific performance of pre-imaging diagnostic algorithms for pulmonary embolism.
van Mens, T E; van der Pol, L M; van Es, N; Bistervels, I M; Mairuhu, A T A; van der Hulle, T; Klok, F A; Huisman, M V; Middeldorp, S
2018-05-01
Essentials Decision rules for pulmonary embolism are used indiscriminately despite possible sex-differences. Various pre-imaging diagnostic algorithms have been investigated in several prospective studies. When analysed at an individual patient data level the algorithms perform similarly in both sexes. Estrogen use and male sex were associated with a higher prevalence in suspected pulmonary embolism. Background In patients suspected of pulmonary embolism (PE), clinical decision rules are combined with D-dimer testing to rule out PE, avoiding the need for imaging in those at low risk. Despite sex differences in several aspects of the disease, including its diagnosis, these algorithms are used indiscriminately in women and men. Objectives To compare the performance, defined as efficiency and failure rate, of three pre-imaging diagnostic algorithms for PE between women and men: the Wells rule with fixed or with age-adjusted D-dimer cut-off, and a recently validated algorithm (YEARS). A secondary aim was to determine the sex-specific prevalence of PE. Methods Individual patient data were obtained from six studies using the Wells rule (fixed D-dimer, n = 5; age adjusted, n = 1) and from one study using the YEARS algorithm. All studies prospectively enrolled consecutive patients with suspected PE. Main outcomes were efficiency (proportion of patients in which the algorithm ruled out PE without imaging) and failure rate (proportion of patients with PE not detected by the algorithm). Outcomes were estimated using (multilevel) logistic regression models. Results The main outcomes showed no sex differences in any of the separate algorithms. With all three, the prevalence of PE was lower in women (OR, 0.66, 0.68 and 0.74). In women, estrogen use, adjusted for age, was associated with lower efficiency and higher prevalence and D-dimer levels. Conclusions The investigated pre-imaging diagnostic algorithms for patients suspected of PE show no sex differences in performance. Male sex and estrogen use are both associated with a higher probability of having the disease. © 2018 International Society on Thrombosis and Haemostasis.
Characteristics of Children with Phonologic Disorders of Unknown Origin.
ERIC Educational Resources Information Center
Shriberg, Lawrence D.; And Others
1986-01-01
Descriptive data are presented from three studies of children referred for assessment of developmental speech disorders. Group findings indicate involvements in mechanism, cognitive, and psychosocial areas. The reliability, learnability, and efficiency of a diagnostic classification system is also considered. (Author/CL)
Wang, Shuqi; Hu, Wei
2014-01-01
Schistosomiasis, caused by dioecious flatworms in the genus Schistosoma, is torturing people from many developing countries nowadays and frequently leads to severe morbidity and mortality of the patients. Praziquantel based chemotherapy and morbidity control for this disease adopted currently necessitate viable and efficient diagnostic technologies. Fortunately, those “-omics” researches, which rely on high-throughput experimental technologies to produce massive amounts of informative data, have substantially contributed to the exploitation and innovation of diagnostic tools of schistosomiasis. In its first section, this review provides a concise conclusion on the progresses pertaining to schistosomal “-omics” researches to date, followed by a comprehensive section on the diagnostic methods of schistosomiasis, especially those innovative ones based on the detection of antibodies, antigens, nucleic acids, and metabolites with a focus on those achievements inspired by “-omics” researches. Finally, suggestions about the design of future diagnostic tools of schistosomiasis are proposed, in order to better harness those data produced by “-omics” studies. PMID:25018752
Cell separation using tilted-angle standing surface acoustic waves
Ding, Xiaoyun; Peng, Zhangli; Lin, Sz-Chin Steven; Geri, Michela; Li, Sixing; Li, Peng; Chen, Yuchao; Dao, Ming; Suresh, Subra; Huang, Tony Jun
2014-01-01
Separation of cells is a critical process for studying cell properties, disease diagnostics, and therapeutics. Cell sorting by acoustic waves offers a means to separate cells on the basis of their size and physical properties in a label-free, contactless, and biocompatible manner. The separation sensitivity and efficiency of currently available acoustic-based approaches, however, are limited, thereby restricting their widespread application in research and health diagnostics. In this work, we introduce a unique configuration of tilted-angle standing surface acoustic waves (taSSAW), which are oriented at an optimally designed inclination to the flow direction in the microfluidic channel. We demonstrate that this design significantly improves the efficiency and sensitivity of acoustic separation techniques. To optimize our device design, we carried out systematic simulations of cell trajectories, matching closely with experimental results. Using numerically optimized design of taSSAW, we successfully separated 2- and 10-µm-diameter polystyrene beads with a separation efficiency of ∼99%, and separated 7.3- and 9.9-µm-polystyrene beads with an efficiency of ∼97%. We illustrate that taSSAW is capable of effectively separating particles–cells of approximately the same size and density but different compressibility. Finally, we demonstrate the effectiveness of the present technique for biological–biomedical applications by sorting MCF-7 human breast cancer cells from nonmalignant leukocytes, while preserving the integrity of the separated cells. The method introduced here thus offers a unique route for separating circulating tumor cells, and for label-free cell separation with potential applications in biological research, disease diagnostics, and clinical practice. PMID:25157150
Cell separation using tilted-angle standing surface acoustic waves.
Ding, Xiaoyun; Peng, Zhangli; Lin, Sz-Chin Steven; Geri, Michela; Li, Sixing; Li, Peng; Chen, Yuchao; Dao, Ming; Suresh, Subra; Huang, Tony Jun
2014-09-09
Separation of cells is a critical process for studying cell properties, disease diagnostics, and therapeutics. Cell sorting by acoustic waves offers a means to separate cells on the basis of their size and physical properties in a label-free, contactless, and biocompatible manner. The separation sensitivity and efficiency of currently available acoustic-based approaches, however, are limited, thereby restricting their widespread application in research and health diagnostics. In this work, we introduce a unique configuration of tilted-angle standing surface acoustic waves (taSSAW), which are oriented at an optimally designed inclination to the flow direction in the microfluidic channel. We demonstrate that this design significantly improves the efficiency and sensitivity of acoustic separation techniques. To optimize our device design, we carried out systematic simulations of cell trajectories, matching closely with experimental results. Using numerically optimized design of taSSAW, we successfully separated 2- and 10-µm-diameter polystyrene beads with a separation efficiency of ∼ 99%, and separated 7.3- and 9.9-µm-polystyrene beads with an efficiency of ∼ 97%. We illustrate that taSSAW is capable of effectively separating particles-cells of approximately the same size and density but different compressibility. Finally, we demonstrate the effectiveness of the present technique for biological-biomedical applications by sorting MCF-7 human breast cancer cells from nonmalignant leukocytes, while preserving the integrity of the separated cells. The method introduced here thus offers a unique route for separating circulating tumor cells, and for label-free cell separation with potential applications in biological research, disease diagnostics, and clinical practice.
Fairfield Plume Measurement and Analysis on the NASA-300M and NASA-300MS
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Shastry, Rohit; Soulas, George C.; Kamhawi, Hani
2013-01-01
NASA is developing a 10- to 15-kW Hall thruster system to support future NASA missions. This activity is funded under the Space Technology Mission Directorate Solar Electric Propulsion Technology Demonstration Mission project. As a part of the development process, the NASA-300M, a 20-kW Hall thruster, was modified to incorporate the magnetic shielding concept and named the NASA-300MS. This activity was undertaken to assess the viability of using the magnetic shielding concept on a high-power Hall thruster to greatly reduce discharge channel erosion. This paper reports on the study to characterize the far-field plumes of the NASA-300M and NASA-300MS. Diagnostics deployed included a polarlyswept Faraday probe, a Wien filter (ExB probe), a retarding potential analyzer, and a Langmuir probe. During the study, a new, more accurate, integration method for analyzing Wien filter probe data was implemented and effect of secondary electron emission on the Faraday probe data was treated. Comparison of the diagnostic results from the two thrusters showed that the magnetically shielded version performed with 2 percent higher voltage utilization efficiency, 2 percent lower plume divergence efficiency, and 2 percent lower mass utilization efficiency compared to the baseline version. The net change in efficiency is within the aggregate measurement uncertainty so the overall performance is roughly equal for the two versions of the thruster. Anode efficiency calculated from thrust stand measurement corroborates this finding.
Ultrasonographic diagnosis of early pregnancy in cattle using different ultrasound systems.
Racewicz, Przemysław; Sickinger, Marlene; Włodarek, Jan; Jaśkowski, Jędrzej M
2016-06-16
To evaluate the efficiency of different ultrasound devices in achieving an early diagnosis of pregnancy in dairy herds. A total of 1976 Holstein Friesian cows and heifers were artificially inseminated (AI) according to the herd manager's regime. Pregnancy diagnostics were performed between day 26 and 35 after AI using six different types of ultrasound systems (linear vs. sector scanners). Manual rectal palpation between day 45 and 60 after AI was used as the gold standard for pregnancy diagnostics. Sensitivity (SENS), specificity (SPEC), positive (PPV) and negative predictive value (NPV) and diagnostic accuracy (ACC) of the diagnostic measures were determined. Average SENS was 82% (range 67.7-95.2%) with a mean SPEC of 73% (range 50.0-81.0%). ACC was 78.2% with a minimum of 64.6% and a maximum of 89.4%, depending on the ultrasound system. The PPV (ratio of the number of pregnant cows with a positive examination result to the number of cows actually pregnant) was 80.8% (range 59.1-88.1%), whereas the NPV (defined as the ratio of the number of cows correctly diagnosed negative to the number of cows actually open) was 74.4% (72.3-91.9%). Significant differences for these parameters were found depending on the ultrasound system used (p ≤ 0.01; Cramer's V. = 0.14). Regardless of the ultrasound device used, early pregnancy diagnostics between day 26 and 35 show a moderate diagnostic efficiency. Comparing the accuracy of the different devices, there may be a significant influence of type and technical parameters. Even though ultrasound systems with mechanical sector probes are not as convenient to use as systems with linear probes, according to this study, sector scanners are a reasonable alternative.
Monroe, Glen R; Frederix, Gerardus W; Savelberg, Sanne M C; de Vries, Tamar I; Duran, Karen J; van der Smagt, Jasper J; Terhal, Paulien A; van Hasselt, Peter M; Kroes, Hester Y; Verhoeven-Duif, Nanda M; Nijman, Isaäc J; Carbo, Ellen C; van Gassen, Koen L; Knoers, Nine V; Hövels, Anke M; van Haelst, Mieke M; Visser, Gepke; van Haaften, Gijs
2016-09-01
This study investigated whole-exome sequencing (WES) yield in a subset of intellectually disabled patients referred to our clinical diagnostic center and calculated the total costs of these patients' diagnostic trajectory in order to evaluate early WES implementation. We compared 17 patients' trio-WES yield with the retrospective costs of diagnostic procedures by comprehensively examining patient records and collecting resource use information for each patient, beginning with patient admittance and concluding with WES initiation. We calculated cost savings using scenario analyses to evaluate the costs replaced by WES when used as a first diagnostic tool. WES resulted in diagnostically useful outcomes in 29.4% of patients. The entire traditional diagnostic trajectory average cost was $16,409 per patient, substantially higher than the $3,972 trio-WES cost. WES resulted in average cost savings of $3,547 for genetic and metabolic investigations in diagnosed patients and $1,727 for genetic investigations in undiagnosed patients. The increased causal variant detection yield by WES and the relatively high costs of the entire traditional diagnostic trajectory suggest that early implementation of WES is a relevant and cost-efficient option in patient diagnostics. This information is crucial for centers considering implementation of WES and serves as input for future value-based research into diagnostics.Genet Med 18 9, 949-956.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G
2014-08-31
The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)
Koçyiğit Deveci, Emel; Ocak, Meltem; Bozkurt, Murat Fani; Türker, Selcan; Kabasakal, Levent; Uğur, Ömer
2013-01-01
Objective: The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-Octreotate in comparison with 111Inpentetrotide scintigraphy in the detection of neuroendocrine tumors. This study also evaluates the impact of SPECT-CT hybrid imaging on somatostatin receptor scintigraphy (SRS) interpretation and clinical management of these tumors. Methods: Fourteen patients were included in the study. All patients underwent a whole body and SPECT-CT imaging with both 99mTc- EDDA/HYNIC-octreotate and 111In-pentetrotide. Images were evaluated both visually and semiquantitatively. Results: On patient basis, the diagnostic results of both studies were similar. The number of lesions detected by 99mTc- EDDA/HYNICOctreotate were higher than the number of lesions detected by 111In-pentetrotide however the difference was not significant (40/43( 93%), 36/43 (83%) p=0.109). Semiquantitative analysis showed higher tumor/organ count ratios for both whole-body and SPECT 99mTc- EDDA/HYNIC-Octreotate scans. Conclusion: The results of this study suggested that, 99mTc- EDDA/HYNIC-Octreotate may be a better alternative to 111In- pentetrotide due to high image quality and lower radiation dose. SPECT/CT is a valuable tool for the assessment of neuroendocrine tumors by providing the precise anatomic localization of scintigraphic findings thus improving lesion detectability and characterization. Conflict of interest:None declared. PMID:24416622
Qin, Shan-yu; Zhou, You; Li, Ping; Jiang, Hai-xing
2014-01-01
Background The diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) cytology varies widely depending on the treatment method of the specimens. The present study aimed to evaluate the diagnostic efficacy of cell block (CB) immunohistochemistry, smear cytology (SC), and liquid-based cytology (LBC) in patients with pancreatic lesions without consulting an on-site cytopathologist. Methods This study prospectively enrolled 72 patients with pancreatic lesions. The EUS-FNA specimens were examined by SC, LBC, and CB immunohistochemistry. The diagnostic efficacy of the 3 methods was then compared. Patients’ final diagnosis was confirmed by surgical resection specimens, diagnostic imaging, and clinical follow-up. Results Our results included 60 malignant and 12 benign pancreatic lesions. The diagnostic sensitivity (90%), negative predictive value (66.7%), and accuracy (91.7%) of CB immunohistochemistry were significantly higher than those of SC (70.0%, 30.0%, and 75.0%, respectively) and LBC (73.3%, 31.6%, and 77.8%, respectively) (all P<0.05). The combination of CB and SC, or CB and LBC, did not significantly increase the efficacy compared to CB immunohistochemistry alone. Conclusion Our findings suggest that in the absence of an on-site cytopathologist, CB immunohistochemistry on EUS-FNA specimens offers a higher diagnostic efficacy in patients with pancreatic lesions than does SC and LBC. PMID:25259861
Dey, Nilanjan; Bose, Soumyo; Das, Achintya; Chaudhuri, Sheli Sinha; Saba, Luca; Shafique, Shoaib; Nicolaides, Andrew; Suri, Jasjit S
2016-04-01
Embedding of diagnostic and health care information requires secure encryption and watermarking. This research paper presents a comprehensive study for the behavior of some well established watermarking algorithms in frequency domain for the preservation of stroke-based diagnostic parameters. Two different sets of watermarking algorithms namely: two correlation-based (binary logo hiding) and two singular value decomposition (SVD)-based (gray logo hiding) watermarking algorithms are used for embedding ownership logo. The diagnostic parameters in atherosclerotic plaque ultrasound video are namely: (a) bulb identification and recognition which consists of identifying the bulb edge points in far and near carotid walls; (b) carotid bulb diameter; and (c) carotid lumen thickness all along the carotid artery. The tested data set consists of carotid atherosclerotic movies taken under IRB protocol from University of Indiana Hospital, USA-AtheroPoint™ (Roseville, CA, USA) joint pilot study. ROC (receiver operating characteristic) analysis was performed on the bulb detection process that showed an accuracy and sensitivity of 100 % each, respectively. The diagnostic preservation (DPsystem) for SVD-based approach was above 99 % with PSNR (Peak signal-to-noise ratio) above 41, ensuring the retention of diagnostic parameter devalorization as an effect of watermarking. Thus, the fully automated proposed system proved to be an efficient method for watermarking the atherosclerotic ultrasound video for stroke application.
Li, Yueyue; Chen, Yang; Wang, Ping
2015-01-01
Impulse oscillometry (IOS) is a good method for measuring airway resistance. The aim of this study was to assess the diagnostic contribution of IOS combined with bronchial dilation test (BDT) when distinguishing between patients with asthma and those with chronic obstructive pulmonary disease (COPD). 870 were enrolled in the study including 561 patients with asthma, 100 patients with COPD and 209 patients with chronic coughing or normal subjects. All the participants underwent routine pulmonary function tests, IOS and BDT examination. And IOS examination was before and after BDT. IOS parameters (R5, R20, R25, R35, X5, X20, X25, X35, Fres, Zrs & RP) and forced expiratory volume in one second (FEV1) were recorded. Receiver operating characteristics (ROC) curve analysis was performed to evaluate the diagnostic ability to differentiate asthma and COPD. The discriminative power of the various parameters studied was determined by means of ROC curves: the area under the curve (AUC), sensitivity and specificity. The X5, X20, X25, X35, Fres, Zrs and Rp correlated better with COPD. In particular, X5, Fres and X25 have been found to be significantly correlated with COPD. The diagnostic efficiency of X5, Fres and X25 when diagnosis COPD, expressed by ROC curve parameters, was as follows: AUC (0.725, 0.730, 0.724), sensitivity (67%, 77%, 83%) and specificity (68%, 65%, 58%), respectively. The diagnostic efficiency of Zrs, R5 and X35 when diagnosis asthma, expressed by ROC curve parameters, was as follows: AUC (0.721, 0.710, 0.695), sensitivity (62%, 72%, 53%) and specificity (72%, 61%, 76%), respectively. Our findings show, that X5, X25 and Fres may be useful for predictions and evaluations for COPD. And R5, X35 and Zrs may provide useful IOS parameters for asthma. IOS combined BDT could be useful diagnostic and differential diagnosis between asthma and COPD. PMID:25785124
Li, Yueyue; Chen, Yang; Wang, Ping
2015-01-01
Impulse oscillometry (IOS) is a good method for measuring airway resistance. The aim of this study was to assess the diagnostic contribution of IOS combined with bronchial dilation test (BDT) when distinguishing between patients with asthma and those with chronic obstructive pulmonary disease (COPD). 870 were enrolled in the study including 561 patients with asthma, 100 patients with COPD and 209 patients with chronic coughing or normal subjects. All the participants underwent routine pulmonary function tests, IOS and BDT examination. And IOS examination was before and after BDT. IOS parameters (R5, R20, R25, R35, X5, X20, X25, X35, Fres, Zrs & RP) and forced expiratory volume in one second (FEV1) were recorded. Receiver operating characteristics (ROC) curve analysis was performed to evaluate the diagnostic ability to differentiate asthma and COPD. The discriminative power of the various parameters studied was determined by means of ROC curves: the area under the curve (AUC), sensitivity and specificity. The X5, X20, X25, X35, Fres, Zrs and Rp correlated better with COPD. In particular, X5, Fres and X25 have been found to be significantly correlated with COPD. The diagnostic efficiency of X5, Fres and X25 when diagnosis COPD, expressed by ROC curve parameters, was as follows: AUC (0.725, 0.730, 0.724), sensitivity (67%, 77%, 83%) and specificity (68%, 65%, 58%), respectively. The diagnostic efficiency of Zrs, R5 and X35 when diagnosis asthma, expressed by ROC curve parameters, was as follows: AUC (0.721, 0.710, 0.695), sensitivity (62%, 72%, 53%) and specificity (72%, 61%, 76%), respectively. Our findings show, that X5, X25 and Fres may be useful for predictions and evaluations for COPD. And R5, X35 and Zrs may provide useful IOS parameters for asthma. IOS combined BDT could be useful diagnostic and differential diagnosis between asthma and COPD.
DNA Charge Transport: From Chemical Principles to the Cell
Arnold, Anna R.; Grodick, Michael A.; Barton, Jacqueline K.
2016-01-01
The DNA double helix has captured the imagination of many, bringing it to the forefront of biological research. DNA has unique features that extend our interest into areas of chemistry, physics, material science and engineering. Our laboratory has focused on studies of DNA charge transport (CT), wherein charges can efficiently travel long molecular distances through the DNA helix while maintaining an exquisite sensitivity to base pair π-stacking. Because DNA CT chemistry reports on the integrity of the DNA duplex, this property may be exploited to develop electrochemical devices to detect DNA lesions and DNA-binding proteins. Furthermore, studies now indicate that DNA CT may also be used in the cell by, for example, DNA repair proteins, as a cellular diagnostic, in order to scan the genome to localize efficiently to damage sites. In this review, we describe this evolution of DNA CT chemistry from the discovery of fundamental chemical principles to applications in diagnostic strategies and possible roles in biology. PMID:26933744
Organizational change through Lean Thinking.
Tsasis, Peter; Bruce-Barrett, Cindy
2008-08-01
In production and manufacturing plants, Lean Thinking has been used to improve processes by eliminating waste and thus enhancing efficiency. In health care, Lean Thinking has emerged as a comprehensive approach towards improving processes embedded in the diagnostic, treatment and care activities of health-care organizations with cost containment results. This paper provides a case study example where Lean Thinking is not only used to improve efficiency and cost containment, but also as an approach to effective organizational change.
Dueholm, M; Christensen, J W; Rydbjerg, S; Hansen, E S; Ørtoft, G
2015-06-01
To evaluate the diagnostic efficiency of two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasonography, power Doppler angiography (PDA) and gel infusion sonography (GIS) at offline analysis for recognition of malignant endometrium compared with real-time evaluation during scanning, and to determine optimal image parameters at 3D analysis. One hundred and sixty-nine consecutive women with postmenopausal bleeding and endometrial thickness ≥ 5 mm underwent systematic evaluation of endometrial pattern on 2D imaging, and 2D videoclips and 3D volumes were later analyzed offline. Histopathological findings at hysteroscopy or hysterectomy were used as the reference standard. The efficiency of the different techniques for diagnosis of malignancy was calculated and compared. 3D image parameters, endometrial volume and 3D vascular indices were assessed. Optimal 3D image parameters were transformed by logistic regression into a risk of endometrial cancer (REC) score, including scores for body mass index, endometrial thickness and endometrial morphology at gray-scale and PDA and GIS. Offline 2D and 3D analysis were equivalent, but had lower diagnostic performance compared with real-time evaluation during scanning. Their diagnostic performance was not markedly improved by the addition of PDA or GIS, but their efficiency was comparable with that of real-time 2D-GIS in offline examinations of good image quality. On logistic regression, the 3D parameters from the REC-score system had the highest diagnostic efficiency. The area under the curve of the REC-score system at 3D-GIS (0.89) was not improved by inclusion of vascular indices or endometrial volume calculations. Real-time evaluation during scanning is most efficient, but offline 2D and 3D analysis is useful for prediction of endometrial cancer when good image quality can be obtained. The diagnostic efficiency at 3D analysis may be improved by use of REC-scoring systems, without the need for calculation of vascular indices or endometrial volume. The optimal imaging modality appears to be real-time 2D-GIS. Copyright © 2014 ISUOG. Published by John Wiley & Sons Ltd.
Mubeen; K.R., Vijayalakshmi; Bhuyan, Sanat Kumar; Panigrahi, Rajat G; Priyadarshini, Smita R; Misra, Satyaranjan; Singh, Chandravir
2014-01-01
Objectives: The identification and radiographic interpretation of periapical bone lesions is important for accurate diagnosis and treatment. The present study was undertaken to study the feasibility and diagnostic accuracy of colour coded digital radiographs in terms of presence and size of lesion and to compare the diagnostic accuracy of colour coded digital images with direct digital images and conventional radiographs for assessing periapical lesions. Materials and Methods: Sixty human dry cadaver hemimandibles were obtained and periapical lesions were created in first and second premolar teeth at the junction of cancellous and cortical bone using a micromotor handpiece and carbide burs of sizes 2, 4 and 6. After each successive use of round burs, a conventional, RVG and colour coded image was taken for each specimen. All the images were evaluated by three observers. The diagnostic accuracy for each bur and image mode was calculated statistically. Results: Our results showed good interobserver (kappa > 0.61) agreement for the different radiographic techniques and for the different bur sizes. Conventional Radiography outperformed Digital Radiography in diagnosing periapical lesions made with Size two bur. Both were equally diagnostic for lesions made with larger bur sizes. Colour coding method was least accurate among all the techniques. Conclusion: Conventional radiography traditionally forms the backbone in the diagnosis, treatment planning and follow-up of periapical lesions. Direct digital imaging is an efficient technique, in diagnostic sense. Colour coding of digital radiography was feasible but less accurate however, this imaging technique, like any other, needs to be studied continuously with the emphasis on safety of patients and diagnostic quality of images. PMID:25584318
Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses.
Yeo, Seon-Ju; Choi, Kyunghan; Cuc, Bui Thi; Hong, Nguyen Ngoc; Bao, Duong Tuan; Ngoc, Nguyen Minh; Le, Mai Quynh; Hang, Nguyen Le Khanh; Thach, Nguyen Co; Mallik, Shyam Kumar; Kim, Hak Sung; Chong, Chom-Kyu; Choi, Hak Soo; Sung, Haan Woo; Yu, Kyoungsik; Park, Hyun
2016-01-01
Field diagnostic tools for avian influenza (AI) are indispensable for the prevention and controlled management of highly pathogenic AI-related diseases. More accurate, faster and networked on-site monitoring is demanded to detect such AI viruses with high sensitivity as well as to maintain up-to-date information about their geographical transmission. In this work, we assessed the clinical and field-level performance of a smartphone-based fluorescent diagnostic device with an efficient reflective light collection module using a coumarin-derived dendrimer-based fluorescent lateral flow immunoassay. By application of an optimized bioconjugate, a smartphone-based diagnostic device had a two-fold higher detectability as compared to that of the table-top fluorescence strip reader for three different AI subtypes (H5N3, H7N1, and H9N2). Additionally, in a clinical study of H5N1-confirmed patients, the smartphone-based diagnostic device showed a sensitivity of 96.55% (28/29) [95% confidence interval (CI): 82.24 to 99.91] and a specificity of 98.55% (68/69) (95% CI: 92.19 to 99.96). The measurement results from the distributed individual smartphones were wirelessly transmitted via short messaging service and collected by a centralized database system for further information processing and data mining. Smartphone-based diagnosis provided highly sensitive measurement results for H5N1 detection within 15 minutes. Because of its high sensitivity, portability and automatic reporting feature, the proposed device will enable agile identification of patients and efficient control of AI dissemination.
Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses
Yeo, Seon-Ju; Choi, Kyunghan; Cuc, Bui Thi; Hong, Nguyen Ngoc; Bao, Duong Tuan; Ngoc, Nguyen Minh; Le, Mai Quynh; Hang, Nguyen Le Khanh; Thach, Nguyen Co; Mallik, Shyam Kumar; Kim, Hak Sung; Chong, Chom-Kyu; Choi, Hak Soo; Sung, Haan Woo; Yu, Kyoungsik; Park, Hyun
2016-01-01
Field diagnostic tools for avian influenza (AI) are indispensable for the prevention and controlled management of highly pathogenic AI-related diseases. More accurate, faster and networked on-site monitoring is demanded to detect such AI viruses with high sensitivity as well as to maintain up-to-date information about their geographical transmission. In this work, we assessed the clinical and field-level performance of a smartphone-based fluorescent diagnostic device with an efficient reflective light collection module using a coumarin-derived dendrimer-based fluorescent lateral flow immunoassay. By application of an optimized bioconjugate, a smartphone-based diagnostic device had a two-fold higher detectability as compared to that of the table-top fluorescence strip reader for three different AI subtypes (H5N3, H7N1, and H9N2). Additionally, in a clinical study of H5N1-confirmed patients, the smartphone-based diagnostic device showed a sensitivity of 96.55% (28/29) [95% confidence interval (CI): 82.24 to 99.91] and a specificity of 98.55% (68/69) (95% CI: 92.19 to 99.96). The measurement results from the distributed individual smartphones were wirelessly transmitted via short messaging service and collected by a centralized database system for further information processing and data mining. Smartphone-based diagnosis provided highly sensitive measurement results for H5N1 detection within 15 minutes. Because of its high sensitivity, portability and automatic reporting feature, the proposed device will enable agile identification of patients and efficient control of AI dissemination. PMID:26877781
Polymerase chain reaction: A molecular diagnostic tool in periodontology
Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam
2016-01-01
This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease. PMID:27143822
Pu, Xia; Ye, Yuanqing; Wu, Xifeng
2014-01-01
Despite the advances made in cancer management over the past few decades, improvements in cancer diagnosis and prognosis are still poor, highlighting the need for individualized strategies. Toward this goal, risk prediction models and molecular diagnostic tools have been developed, tailoring each step of risk assessment from diagnosis to treatment and clinical outcomes based on the individual's clinical, epidemiological, and molecular profiles. These approaches hold increasing promise for delivering a new paradigm to maximize the efficiency of cancer surveillance and efficacy of treatment. However, they require stringent study design, methodology development, comprehensive assessment of biomarkers and risk factors, and extensive validation to ensure their overall usefulness for clinical translation. In the current study, the authors conducted a systematic review using breast cancer as an example and provide general guidelines for risk prediction models and molecular diagnostic tools, including development, assessment, and validation. © 2013 American Cancer Society.
Polymerase chain reaction: A molecular diagnostic tool in periodontology.
Maheaswari, Rajendran; Kshirsagar, Jaishree Tukaram; Lavanya, Nallasivam
2016-01-01
This review discusses the principles of polymerase chain reaction (PCR) and its application as a diagnostic tool in periodontology. The relevant MEDLINE and PubMed indexed journals were searched manually and electronically by typing PCR, applications of PCR, PCR in periodontics, polymorphism studies in periodontitis, and molecular techniques in periodontology. The searches were limited to articles in English language and the articles describing PCR process and its relation to periodontology were collected and used to prepare a concise review. PCR has now become a standard diagnostic and research tool in periodontology. Various studies reveal that its sensitivity and specificity allow it as a rapid, efficient method of detecting, identifying, and quantifying organism. Different immune and inflammatory markers can be identified at the mRNA expression level, and also the determination of genetic polymorphisms, thus providing the deeper insight into the mechanisms underlying the periodontal disease.
Jérôme, Marc; Martinsohn, Jann Thorsten; Ortega, Delphine; Carreau, Philippe; Verrez-Bagnis, Véronique; Mouchel, Olivier
2008-05-28
Traceability in the fish food sector plays an increasingly important role for consumer protection and confidence building. This is reflected by the introduction of legislation and rules covering traceability on national and international levels. Although traceability through labeling is well established and supported by respective regulations, monitoring and enforcement of these rules are still hampered by the lack of efficient diagnostic tools. We describe protocols using a direct sequencing method based on 212-274-bp diagnostic sequences derived from species-specific mitochondria DNA cytochrome b, 16S rRNA, and cytochrome oxidase subunit I sequences which can efficiently be applied to unambiguously determine even closely related fish species in processed food products labeled "anchovy". Traceability of anchovy-labeled products is supported by the public online database AnchovyID ( http://anchovyid.jrc.ec.europa.eu), which provided data obtained during our study and tools for analytical purposes.
Diagnostic efficiency of an ability-focused battery.
Miller, Justin B; Fichtenberg, Norman L; Millis, Scott R
2010-05-01
An ability-focused battery (AFB) is a selected group of well-validated neuropsychological measures that assess the conventional range of cognitive domains. This study examined the diagnostic efficiency of an AFB for use in clinical decision making with a mixed sample composed of individuals with neurological brain dysfunction and individuals referred for cognitive assessment without evidence of neurological disorders. Using logistic regression analyses and ROC curve analysis, a five-domain model composed of attention, processing speed, visual-spatial reasoning, language/verbal reasoning, and memory domain scores was fitted that had an AUC of.89 (95% CI =.84-.95). A more parsimonious two-domain model using processing speed and memory was also fitted that had an AUC of.90 (95% confidence interval =.84-.95). A model composed of a global ability score calculated from the mean of the individual domain scores was also fitted with an AUC of.88 (95% CI =.82-.94).
Brewer, D E
2000-09-01
The results of cardiac tests must always be interpreted through the lens of pretest probabilities created by the history and the physical examination. Tests should be chosen with a clear diagnostic and prognostic purpose in mind. A clear understanding of the relationship between the history and physical examination and more technologic diagnostic testing improves the primary care physician's ability to evaluate potential cardiac disease in an efficient and cost-effective manner.
ERIC Educational Resources Information Center
Youngstrom, Eric A.; Findling, Robert L.; Calabrese, Joseph R.; Gracious, Barbara L.; Demeter, Christine; DelPorto Bedoya, Denise; Price, Megan
2004-01-01
Objective: To compare the diagnostic efficiency of six index tests as predictors of juvenile bipolar disorder in two large outpatient samples, aged 5 to 10 and 11 to 17 years, gathered from 1997 to 2002. Method: DSM-IV diagnosis was based on a semistructured diagnostic interview (Schedule for Affective Disorders and Schizophrenia for School-Age…
Jin, Ting; Fei, Baoying; Zhang, Yu; He, Xujun
2017-01-01
Intestinal tuberculosis (ITB) and Crohn's disease (CD) are important differential diagnoses that can be difficult to distinguish. Polymerase chain reaction (PCR) for Mycobacterium tuberculosis (MTB) is an efficient and promising tool. This meta-analysis was performed to systematically and objectively assess the potential diagnostic accuracy and clinical value of PCR for MTB in distinguishing ITB from CD. We searched PubMed, Embase, Web of Science, Science Direct, and the Cochrane Library for eligible studies, and nine articles with 12 groups of data were identified. The included studies were subjected to quality assessment using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The summary estimates were as follows: sensitivity 0.47 (95% CI: 0.42-0.51); specificity 0.95 (95% CI: 0.93-0.97); the positive likelihood ratio (PLR) 10.68 (95% CI: 6.98-16.35); the negative likelihood ratio (NLR) 0.49 (95% CI: 0.33-0.71); and diagnostic odds ratio (DOR) 21.92 (95% CI: 13.17-36.48). The area under the curve (AUC) was 0.9311, with a Q* value of 0.8664. Heterogeneity was found in the NLR. The heterogeneity of the studies was evaluated by meta-regression analysis and subgroup analysis. The current evidence suggests that PCR for MTB is a promising and highly specific diagnostic method to distinguish ITB from CD. However, physicians should also keep in mind that negative results cannot exclude ITB for its low sensitivity. Additional prospective studies are needed to further evaluate the diagnostic accuracy of PCR.
NASA Astrophysics Data System (ADS)
Kasper, Axel; Van Hille, Herbert; Kuk, Sola
2018-02-01
Modern instruments for molecular diagnostics are continuously optimized for diagnostic accuracy, versatility and throughput. The latest progress in LED technology together with tailored optics solutions allows developing highly efficient photonics engines perfectly adapted to the sample under test. Super-bright chip-on-board LED light sources are a key component for such instruments providing maximum luminous intensities in a multitude of narrow spectral bands. In particular the combination of white LEDs with other narrow band LEDs allows achieving optimum efficiency outperforming traditional Xenon light sources in terms of energy consumption, heat dissipation in the system, and switching time between spectral channels. Maximum sensitivity of the diagnostic system can only be achieved with an optimized optics system for the illumination and imaging of the sample. The illumination beam path must be designed for optimum homogeneity across the field while precisely limiting the angular distribution of the excitation light. This is a necessity for avoiding spill-over to the detection beam path and guaranteeing the efficiency of the spectral filtering. The imaging optics must combine high spatial resolution, high light collection efficiency and optimized suppression of excitation light for good signal-to-noise ratio. In order to achieve minimum cross-talk between individual wells in the sample, the optics design must also consider the generation of stray light and the formation of ghost images. We discuss what parameters and limitations have to be considered in an integrated system design approach covering the full path from the light source to the detector.
Multi-method automated diagnostics of rotating machines
NASA Astrophysics Data System (ADS)
Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.
2017-08-01
The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.
Obuchowski, N A
2001-10-15
Electronic medical images are an efficient and convenient format in which to display, store and transmit radiographic information. Before electronic images can be used routinely to screen and diagnose patients, however, it must be shown that readers have the same diagnostic performance with this new format as traditional hard-copy film. Currently, there exist no suitable definitions of diagnostic equivalence. In this paper we propose two criteria for diagnostic equivalence. The first criterion ('population equivalence') considers the variability between and within readers, as well as the mean reader performance. This criterion is useful for most applications. The second criterion ('individual equivalence') involves a comparison of the test results for individual patients and is necessary when patients are followed radiographically over time. We present methods for testing both individual and population equivalence. The properties of the proposed methods are assessed in a Monte Carlo simulation study. Data from a mammography screening study is used to illustrate the proposed methods and compare them with results from more conventional methods of assessing equivalence and inter-procedure agreement. Copyright 2001 John Wiley & Sons, Ltd.
Automated Bus Diagnostic System Demonstration in New York City
DOT National Transportation Integrated Search
1983-12-01
In response to a growing problem with the quality and efficiency of nationwide bus maintenance practices, an award was granted to the Tri-State Regional Planning Commission for the testing of an automated bus diagnostic system (ABDS). The ABDS was de...
Owen, Rhiannon K; Cooper, Nicola J; Quinn, Terence J; Lees, Rosalind; Sutton, Alex J
2018-07-01
Network meta-analyses (NMA) have extensively been used to compare the effectiveness of multiple interventions for health care policy and decision-making. However, methods for evaluating the performance of multiple diagnostic tests are less established. In a decision-making context, we are often interested in comparing and ranking the performance of multiple diagnostic tests, at varying levels of test thresholds, in one simultaneous analysis. Motivated by an example of cognitive impairment diagnosis following stroke, we synthesized data from 13 studies assessing the efficiency of two diagnostic tests: Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA), at two test thresholds: MMSE <25/30 and <27/30, and MoCA <22/30 and <26/30. Using Markov chain Monte Carlo (MCMC) methods, we fitted a bivariate network meta-analysis model incorporating constraints on increasing test threshold, and accounting for the correlations between multiple test accuracy measures from the same study. We developed and successfully fitted a model comparing multiple tests/threshold combinations while imposing threshold constraints. Using this model, we found that MoCA at threshold <26/30 appeared to have the best true positive rate, whereas MMSE at threshold <25/30 appeared to have the best true negative rate. The combined analysis of multiple tests at multiple thresholds allowed for more rigorous comparisons between competing diagnostics tests for decision making. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Vitte, Joana; Ranque, Stéphane; Carsin, Ania; Gomez, Carine; Romain, Thomas; Cassagne, Carole; Gouitaa, Marion; Baravalle-Einaudi, Mélisande; Bel, Nathalie Stremler-Le; Reynaud-Gaubert, Martine; Dubus, Jean-Christophe; Mège, Jean-Louis; Gaudart, Jean
2017-01-01
Molecular-based allergy diagnosis yields multiple biomarker datasets. The classical diagnostic score for allergic bronchopulmonary aspergillosis (ABPA), a severe disease usually occurring in asthmatic patients and people with cystic fibrosis, comprises succinct immunological criteria formulated in 1977: total IgE, anti- Aspergillus fumigatus ( Af ) IgE, anti- Af "precipitins," and anti- Af IgG. Progress achieved over the last four decades led to multiple IgE and IgG(4) Af biomarkers available with quantitative, standardized, molecular-level reports. These newly available biomarkers have not been included in the current diagnostic criteria, either individually or in algorithms, despite persistent underdiagnosis of ABPA. Large numbers of individual biomarkers may hinder their use in clinical practice. Conversely, multivariate analysis using new tools may bring about a better chance of less diagnostic mistakes. We report here a proof-of-concept work consisting of a three-step multivariate analysis of Af IgE, IgG, and IgG4 biomarkers through a combination of principal component analysis, hierarchical ascendant classification, and classification and regression tree multivariate analysis. The resulting diagnostic algorithms might show the way for novel criteria and improved diagnostic efficiency in Af -sensitized patients at risk for ABPA.
Can CT imaging features of ground-glass opacity predict invasiveness? A meta-analysis.
Dai, Jian; Yu, Guoyou; Yu, Jianqiang
2018-04-01
A meta-analysis was conducted to investigate the diagnostic performance of computed tomography (CT) imaging features of ground-glass opacity (GGO) to predict invasiveness. Two reviewers independently searched PubMed, Medline, Web of Science, Cochrane Embase and CNKI for relevant studies. CT imaging signs of bubble lucency, speculation, lobulated margin, and pleural indentation were used as diagnostic references to discriminate pre-invasive and invasive disease. The sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the area under the SROC curve (AUC) were calculated to evaluate diagnostic efficiency. Twelve studies were finally included. Diagnostic performance ranged from 0.41 to 0.52 for sensitivity and 0.56 to 0.63 for specificity. The diagnostic positive and negative likelihood ratios ranged from 1.03 to 2.13 and 0.52 to 1.05, respectively. The DORs of the GGO CT features for discriminating invasive disease ranged from 1.02 to 4.00. The area under the ROC curve was also low, with a range of 0.60 to 0.67 for discriminating pre-invasive and invasive disease. The diagnostic value of a single CT imaging sign of GGO, such as bubble lucency, speculation, lobulated margin, or pleural indentation is limited for discriminating pre-invasive and invasive disease because of low sensitivity, specificity, and AUC. © 2018 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.
NASA Astrophysics Data System (ADS)
Usova, A.; Frolova, I.; Afanasev, S.; Tarasova, A.; Molchanov, S.
2016-02-01
Experiment of use of MRI in diagnostics of rectovaginal fistulas after combination therapy of rectal cancer is shown on clinical examples. We used retrograde contrasting of a rectum with 150ml ultrasonic gel to make MRI more informative in case of low diagnostic efficiency of ultrasound, colonoscopy and gynecological examination.
Szylberg, Łukasz
2014-01-01
Hirschsprung's disease (HD) is a disorder that involves several medical specialties such as paediatric gastroenterology, paediatric surgery, and pathology. Hirschsprung's disease is a congenital bowel innervation disorder characterised by the absence of ganglion cells in myenteric (Auerbach) and submucosal (Meissner) plexus in the distal colon in its classical form. Rapid and accurate diagnosis of HD is a key element in further treatment patterns. The efficiency of different diagnostic methods used in HD patients may vary. Using one limited diagnostic procedure can lead to as much as a few per cent of overlooked cases. In recent years, rectal biopsy was recognised as an important diagnostic tool that allows for a definitive HD diagnosis with an accuracy of 95% of cases. A correct diagnosis depends on the localisation of the biopsied sample, its representativeness, the number of specimens, and proper interpretation of microscopic studies supported by histochemical and immunohistochemical methods. When several methods are used and all diagnostic criteria are used, the diagnostic sensitivity can almost eliminate cases of undiagnosed patients. PMID:25395999
The diagnostic management of upper extremity deep vein thrombosis: A review of the literature.
Kraaijpoel, Noémie; van Es, Nick; Porreca, Ettore; Büller, Harry R; Di Nisio, Marcello
2017-08-01
Upper extremity deep vein thrombosis (UEDVT) accounts for 4% to 10% of all cases of deep vein thrombosis. UEDVT may present with localized pain, erythema, and swelling of the arm, but may also be detected incidentally by diagnostic imaging tests performed for other reasons. Prompt and accurate diagnosis is crucial to prevent pulmonary embolism and long-term complications as the post-thrombotic syndrome of the arm. Unlike the diagnostic management of deep vein thrombosis (DVT) of the lower extremities, which is well established, the work-up of patients with clinically suspected UEDVT remains uncertain with limited evidence from studies of small size and poor methodological quality. Currently, only one prospective study evaluated the use of an algorithm, similar to the one used for DVT of the lower extremities, for the diagnostic workup of clinically suspected UEDVT. The algorithm combined clinical probability assessment, D-dimer testing and ultrasonography and appeared to safely and effectively exclude UEDVT. However, before recommending its use in routine clinical practice, external validation of this strategy and improvements of the efficiency are needed, especially in high-risk subgroups in whom the performance of the algorithm appeared to be suboptimal, such as hospitalized or cancer patients. In this review, we critically assess the accuracy and efficacy of current diagnostic tools and provide clinical guidance for the diagnostic management of clinically suspected UEDVT. Copyright © 2017 Elsevier Ltd. All rights reserved.
RAMAN spectroscopy imaging improves the diagnosis of papillary thyroid carcinoma
NASA Astrophysics Data System (ADS)
Rau, Julietta V.; Graziani, Valerio; Fosca, Marco; Taffon, Chiara; Rocchia, Massimiliano; Crucitti, Pierfilippo; Pozzilli, Paolo; Onetti Muda, Andrea; Caricato, Marco; Crescenzi, Anna
2016-10-01
Recent investigations strongly suggest that Raman spectroscopy (RS) can be used as a clinical tool in cancer diagnosis to improve diagnostic accuracy. In this study, we evaluated the efficiency of Raman imaging microscopy to discriminate between healthy and neoplastic thyroid tissue, by analyzing main variants of Papillary Thyroid Carcinoma (PTC), the most common type of thyroid cancer. We performed Raman imaging of large tissue areas (from 100 × 100 μm2 up to 1 × 1 mm2), collecting 38 maps containing about 9000 Raman spectra. Multivariate statistical methods, including Linear Discriminant Analysis (LDA), were applied to translate Raman spectra differences between healthy and PTC tissues into diagnostically useful information for a reliable tissue classification. Our study is the first demonstration of specific biochemical features of the PTC profile, characterized by significant presence of carotenoids with respect to the healthy tissue. Moreover, this is the first evidence of Raman spectra differentiation between classical and follicular variant of PTC, discriminated by LDA with high efficiency. The combined histological and Raman microscopy analyses allow clear-cut integration of morphological and biochemical observations, with dramatic improvement of efficiency and reliability in the differential diagnosis of neoplastic thyroid nodules, paving the way to integrative findings for tumorigenesis and novel therapeutic strategies.
Schnabel, M; Mann, D; Efe, T; Schrappe, M; V Garrel, T; Gotzen, L; Schaeg, M
2004-10-01
The introduction of the German Diagnostic Related Groups (D-DRG) system requires redesigning administrative patient management strategies. Wrong coding leads to inaccurate grouping and endangers the reimbursement of treatment costs. This situation emphasizes the roles of documentation and coding as factors of economical success. The aims of this study were to assess the quantity and quality of initial documentation and coding (ICD-10 and OPS-301) and find operative strategies to improve efficiency and strategic means to ensure optimal documentation and coding quality. In a prospective study, documentation and coding quality were evaluated in a standardized way by weekly assessment. Clinical data from 1385 inpatients were processed for initial correctness and quality of documentation and coding. Principal diagnoses were found to be accurate in 82.7% of cases, inexact in 7.1%, and wrong in 10.1%. Effects on financial returns occurred in 16%. Based on these findings, an optimized, interdisciplinary, and multiprofessional workflow on medical documentation, coding, and data control was developed. Workflow incorporating regular assessment of documentation and coding quality is required by the DRG system to ensure efficient accounting of hospital services. Interdisciplinary and multiprofessional cooperation is recognized to be an important factor in establishing an efficient workflow in medical documentation and coding.
Schaafsma, Joanna D; van der Graaf, Yolanda; Rinkel, Gabriel J E; Buskens, Erik
2009-12-01
The lack of a standard methodology in diagnostic research impedes adequate evaluation before implementation of constantly developing diagnostic techniques. We discuss the methodology of diagnostic research and underscore the relevance of decision analysis in the process of evaluation of diagnostic tests. Overview and conceptual discussion. Diagnostic research requires a stepwise approach comprising assessment of test characteristics followed by evaluation of added value, clinical outcome, and cost-effectiveness. These multiple goals are generally incompatible with a randomized design. Decision-analytic models provide an important alternative through integration of the best available evidence. Thus, critical assessment of clinical value and efficient use of resources can be achieved. Decision-analytic models should be considered part of the standard methodology in diagnostic research. They can serve as a valid alternative to diagnostic randomized clinical trials (RCTs).
JPRS Report, Science & Technology, Europe & Latin America.
1988-01-21
this way we can analyze the elements that control the 27 cell-specific and temporal expression of genes, and study the effects of genie expression... effects of new genetic diversity that a scientific basis will be created for the establishment of efficient regulation. 5) Feasibility studies for...which I am involved inatituted a multi- centric study to evaluate the real clinical applicability and diagnostic effectiveness of associating
Tiwari, Dileep; Haque, Shafiul; Tiwari, Ram P; Jawed, Arshad; Govender, Thavendran; Kruger, Hendrik G
2017-04-01
A rapid and efficient diagnostic test was developed for the detection of Mycobacterium tuberculosis antigens in serum samples of active tuberculosis (TB) and extrapulmonary TB patients via a liposomal agglutination-based method. A rapid card test has been developed to facilitate the recognition of high-affinity binding rabbit raised purified culture filtrate protein antibodies coupled on the surface of activated liposomal preparation. In the presence of TB antigens, the polyclonal antibodies bound to the liposomal particles demonstrate a visible agglutination reaction. The developed assay was simple, rapid, reliable, sensitive, and specific as a diagnostic test for the detection of antigens in serum samples of clinically confirmed cases of TB within 4-5 minutes' duration. The test was evaluated at different hospitals, medical colleges, and pathology centers, and involved 1483 participants. This investigation was conducted to detect the presence of these antigens during the period of active growth of the microorganism in serum samples for pulmonary TB and processed tissue biopsy for other extrapulmonary TB. Results obtained using this test were compared with acid-fast bacilli smear and culture results. Our study demonstrated that the newly developed liposome tuberculosis antigen card test detected antigens in our study population with approximately 97.48% sensitivity and 95.79% specificity. This is the first study to report the liposomal encapsulation of culture filtrate proteins from M. tuberculosis for diagnostic application. Copyright © 2015. Published by Elsevier B.V.
Efficiency of the Bethesda System for Thyroid Cytopathology.
Mora-Guzmán, Ismael; Muñoz de Nova, José Luis; Marín-Campos, Cristina; Jiménez-Heffernan, José Antonio; Cuesta Pérez, Juan Julián; Lahera Vargas, Marcos; Torres Mínguez, Emma; Martín-Pérez, Elena
2018-03-28
Fine-needle aspiration biopsies are a key tool for preoperative assessment of thyroid nodules, and the Bethesda system is the preferred method to report cytological analysis. The purpose of this study is to assess the efficiency of the Bethesda system to identify the malignancy risk of thyroid nodules. Patients who underwent thyroid surgery between June 2010 and June 2017 were included. Samples were classified into 6categories according to rates of malignancy associated with each diagnostic category. In order to investigate the correlation between categories, a statistical analysis compared the categories with pathology reports. Diagnostic indicators were calculated as a screening test (categories IV, V, VI as true-positive) and as a method to identify malignancy (V, VI as true-positive). In a series of 522 patients, we found 184 (35.2%) malignant tumours, papillary carcinoma being the most prevalent with 155 cases (84.2%). Malignant rates for diagnostic categories were: I, 0%; II, 1.5%; III, 6.4%; IV, 31%; V, 86.5%; VI, 100%. A robust correlation was identified between categories on statistical analysis. For the «screening test» analysis, sensitivity was 98.9%, specificity 84.4%, positive predictive value 69.6%, negative predictive value 99.5%, and diagnostic accuracy 88.2%. Analysing the accuracy to detect malignancy, values were: sensitivity 98.6%, specificity 97.6%, positive predictive value 93.5%, negative predictive value 99.5%, diagnostic accuracy 97.9%. The Bethesda system is a clear and reliable approach to report thyroid cytology and therefore is an effective tool to identify malignancy risk and guide clinical management. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
CHANGING OUR DIAGNOSTIC PARADIGM: MOVEMENT SYSTEM DIAGNOSTIC CLASSIFICATION
Kamonseki, Danilo H.; Staker, Justin L.; Lawrence, Rebekah L.; Braman, Jonathan P.
2017-01-01
Proper diagnosis is a first step in applying best available treatments, and prognosticating outcomes for clients. Currently, the majority of musculoskeletal diagnoses are classified according to pathoanatomy. However, the majority of physical therapy treatments are applied toward movement system impairments or pain. While advocated within the physical therapy profession for over thirty years, diagnostic classification within a movement system framework has not been uniformly developed or adopted. We propose a basic framework and rationale for application of a movement system diagnostic classification for atraumatic shoulder pain conditions, as a case for the broader development of movement system diagnostic labels. Shifting our diagnostic paradigm has potential to enhance communication, improve educational efficiency, facilitate research, directly link to function, improve clinical care, and accelerate preventive interventions. PMID:29158950
Murphy, Danielle A.; Ely, Heather A.; Shoemaker, Robert; Boomer, Aaron; Culver, Brady P.; Hoskins, Ian; Haimes, Josh D.; Walters, Ryan D.; Fernandez, Diane; Stahl, Joshua A.; Lee, Jeeyun; Kim, Kyoung-Mee; Lamoureux, Jennifer
2017-01-01
Targeted therapy combined with companion diagnostics has led to the advancement of next-generation sequencing (NGS) for detection of molecular alterations. However, using a diagnostic test to identify patient populations with low prevalence molecular alterations, such as gene rearrangements, poses efficiency, and cost challenges. To address this, we have developed a 2-step diagnostic test to identify NTRK1, NTRK2, NTRK3, ROS1, and ALK rearrangements in formalin-fixed paraffin-embedded clinical specimens. This test is comprised of immunohistochemistry screening using a pan-receptor tyrosine kinase cocktail of antibodies to identify samples expressing TrkA (encoded by NTRK1), TrkB (encoded by NTRK2), TrkC (encoded by NTRK3), ROS1, and ALK followed by an RNA-based anchored multiplex polymerase chain reaction NGS assay. We demonstrate that the NGS assay is accurate and reproducible in identification of gene rearrangements. Furthermore, implementation of an RNA quality control metric to assess the presence of amplifiable nucleic acid input material enables a measure of confidence when an NGS result is negative for gene rearrangements. Finally, we demonstrate that performing a pan-receptor tyrosine kinase immunohistochemistry staining enriches detection of the patient population for gene rearrangements from 4% to 9% and has a 100% negative predictive value. Together, this 2-step assay is an efficient method for detection of gene rearrangements in both clinical testing and studies of archival formalin-fixed paraffin-embedded specimens. PMID:27028240
Ehling-Schulz, Monika; Messelhäusser, Ute
2013-01-01
The highly heterogeneous genus Bacillus comprises the largest species group of endospore forming bacteria. Because of their ubiquitous nature, Bacillus spores can enter food production at several stages resulting in significant economic losses and posing a potential risk to consumers due the capacity of certain Bacillus strains for toxin production. In the past, food microbiological diagnostics was focused on the determination of species using conventional culture-based methods, which are still widely used. However, due to the extreme intra-species diversity found in the genus Bacillus, DNA-based identification and typing methods are gaining increasing importance in routine diagnostics. Several studies showed that certain characteristics are rather strain-dependent than species-specific. Therefore, the challenge for current and future Bacillus diagnostics is not only the efficient and accurate identification on species level but also the development of rapid methods to identify strains with specific characteristics (such as stress resistance or spoilage potential), trace contamination sources, and last but not least discriminate potential hazardous strains from non-toxic strains.
The diagnostic adaptive behavior scale: evaluating its diagnostic sensitivity and specificity.
Balboni, Giulia; Tassé, Marc J; Schalock, Robert L; Borthwick-Duffy, Sharon A; Spreat, Scott; Thissen, David; Widaman, Keith F; Zhang, Dalun; Navas, Patricia
2014-11-01
The Diagnostic Adaptive Behavior Scale (DABS) was constructed with items across three domains--conceptual, social, and practical adaptive skills--and normed on a representative sample of American individuals from 4 to 21 years of age. The DABS was developed to focus its assessment around the decision point for determining the presence or absence of significant limitations of adaptive behavior for the diagnosis of Intellectual Disability (ID). The purpose of this study, which was composed of 125 individuals with and 933 without an ID-related diagnosis, was to determine the ability of the DABS to correctly identify the individuals with and without ID (i.e., sensitivity and specificity). The results indicate that the DABS sensitivity coefficients ranged from 81% to 98%, specificity coefficients ranged from 89% to 91%, and that the Area Under the Receiver Operating Characteristic Curve were excellent or good. These results indicate that the DABS has very good levels of diagnostic efficiency. Copyright © 2014. Published by Elsevier Ltd.
Loveday, Thomas; Wiggins, Mark W; Searle, Ben J; Festa, Marino; Schell, David
2013-02-01
The authors describe the development of a new, more objective method of distinguishing experienced competent nonexpert from expert practitioners within pediatric intensive care. Expert performance involves the acquisition and use of refined feature-event associations (cues) in the operational environment. Competent non-experts, although experienced, possess rudimentary cue associations in memory. Thus, they cannot respond as efficiently or as reliably as their expert counterparts, particularly when key diagnostic information is unavailable, such as that provided by dynamic cues. This study involved the application of four distinct tasks in which the use of relevant cues could be expected to increase both the accuracy and the efficiency of diagnostic performance. These tasks included both static and dynamic stimuli that were varied systematically. A total of 50 experienced pediatric intensive staff took part in the study. The sample clustered into two levels across the tasks: Participants who performed at a consistently high level throughout the four tasks were labeled experts, and participants who performed at a lower level throughout the tasks were labeled competent nonexperts. The groups differed in their responses to the diagnostic scenarios presented in two of the tasks and their ability to maintain performance in the absence of dynamic features. Experienced pediatricians can be decomposed into two groups on the basis of their capacity to acquire and use cues; these groups differ in their diagnostic accuracy and in their ability to maintain performance in the absence of dynamic features. The tasks may be used to identify practitioners who are failing to acquire expertise at a rate consistent with their experience, position, or training. This information may be used to guide targeted training efforts.
Employing Online S-P Diagnostic Table for Qualitative Comments on Test Results
ERIC Educational Resources Information Center
Wang, Chien-hwa; Chen, Cheng-ping
2013-01-01
The major concerns of adaptive testing studies have concentrated on effectiveness and efficiency of the system built for the research experiments. It has been criticised that such general information has fallen short of providing qualitative descriptions regarding learning performance. Takahiro Sato of Japan proposed an analytical diagram called…
Evaluation Methods Basis of Strategy Development Effectiveness of the Enterprise
ERIC Educational Resources Information Center
Zotova, Anna S.; Kandrashina, Elena A.; Ivliev, Andrey D.; Charaeva, Marina V.
2016-01-01
The urgency to study the problem is caused by the necessity to make management decisions in terms of reducing goods life cycle, reducing profitability of production, increasing speed of technological progress. In this context, this article aims to identify and elaborate the tools for integrated diagnostic of strategy efficiency, taking into…
Multiple-Stage Screening of Youth Depression in Schools
ERIC Educational Resources Information Center
Morey, Melissa E.; Arora, Prerna; Stark, Kevin D.
2015-01-01
Schools present a unique environment in which to conduct universal screenings for youth depression. The present study examines the efficiency of a multiple-stage assessment procedure assessing youth depression in the schools by calculating hit rates and establishing diagnostic accuracy for the measures used. Girls (N = 3318) aged 8 to 13,…
ERIC Educational Resources Information Center
Kuo, Fan-Ray; Chin, Yi-Ying; Lee, Chao-Hsien; Chiu, Yu-Hsien; Hong, Chien-Hu; Lee, Kuang-Lieh; Ho, Wen-Hsien; Lee, Chih-Hung
2016-01-01
Few studies have explored the learning difficulties and misconceptions that students encounter when using information and communication technology for e-learning. To address this issue, this research developed a system for evaluating the learning efficiency of medical students by applying two-tier diagnosis assessment. The effectiveness of the…
A simple diagnostic model for ruling out pneumoconiosis among construction workers.
Suarthana, Eva; Moons, Karel G M; Heederik, Dick; Meijer, Evert
2007-09-01
Construction workers exposed to silica-containing dust are at risk of developing silicosis even at low exposure levels. Health surveillance among these workers is commonly advised but the exact diagnostic work-up is not specified and therefore may result in unnecessary chest x ray investigations. To develop a simple diagnostic model to estimate the probability of an individual worker having pneumoconiosis from questionnaire and spirometry results, in order to accurately rule out workers without pneumoconiosis. The study was performed using cross-sectional data of 1291 Dutch natural stone and construction workers with potentially high quartz dust exposure. A multivariable logistic regression model was developed using chest x ray with ILO profusion category > or =1/1 as the reference standard. The model's calibration was evaluated with the Hosmer-Lemeshow test; the discriminative ability was determined by calculating the area under the receiver operating characteristic curve (ROC area). Internal validity of the final model was assessed by a bootstrapping procedure. For clinical application, the diagnostic model was transformed into an easy-to-use score chart. Age 40 years or older, current smoker, high-exposure job, working 15 years or longer in the construction industry, "feeling unhealthy" and FEV1 were independent predictors in the diagnostic model. The model showed good calibration (a non-significant Hosmer-Lemeshow test) and discriminative ability (ROC area 0.81, 95% CI 0.74 to 0.85). Internal validity was reasonable; the optimism corrected ROC area was 0.76. By using a cut-off point with a high negative predictive value the occupational physician can efficiently detect a large proportion of workers with a low probability of having pneumoconiosis and exclude them from unnecessary x ray investigations. This diagnostic model is an efficient and effective instrument to rule out pneumoconiosis among construction workers. Its use in health surveillance among these workers can reduce the number of redundant x ray investigations.
Proton exchange membrane fuel cell system diagnosis based on the signed directed graph method
NASA Astrophysics Data System (ADS)
Hua, Jianfeng; Lu, Languang; Ouyang, Minggao; Li, Jianqiu; Xu, Liangfei
The fuel-cell powered bus is becoming the favored choice for electric vehicles because of its extended driving range, zero emissions, and high energy conversion efficiency when compared with battery-operated electric vehicles. In China, a demonstration program for the fuel cell bus fleet operated at the Beijing Olympics in 2008 and the Shanghai Expo in 2010. It is necessary to develop comprehensive proton exchange membrane fuel cell (PEMFC) diagnostic tools to increase the reliability of these systems. It is especially critical for fuel-cell city buses serving large numbers of passengers using public transportation. This paper presents a diagnostic analysis and implementation study based on the signed directed graph (SDG) method for the fuel-cell system. This diagnostic system was successfully implemented in the fuel-cell bus fleet at the Shanghai Expo in 2010.
NASA Astrophysics Data System (ADS)
Stefan, V. Alexander
2014-10-01
A novel method for alpha particle diagnostics is proposed. The theory of stimulated Raman scattering, SRS, of the fast wave and ion Bernstein mode, IBM, turbulence in multi-ion species plasmas, (Stefan University Press, La Jolla, CA, 2008). is utilized for the diagnostics of fast ions, (4)He (+2), in ITER plasmas. Nonlinear Landau damping of the IBM on fast ions near the plasma edge leads to the space-time changes in the turbulence level, (inverse alpha particle channeling). The space-time monitoring of the IBM turbulence via the SRS techniques may prove efficient for the real time study of the fast ion velocity distribution function, spatial distribution, and transport. Supported by Nikola Tesla Labs., La Jolla, CA 92037.
SUMIE, HIROAKI; SUMIE, SHUJI; NAKAHARA, KEITA; WATANABE, YASUTOMO; MATSUO, KEN; MUKASA, MICHITA; SAKAI, TAKESHI; YOSHIDA, HIKARU; TSURUTA, OSAMU; SATA, MICHIO
2014-01-01
The usefulness of magnifying endoscopy with narrow-band imaging (ME-NBI) for the diagnosis of early gastric cancer is well known, however, there are no evaluation criteria. The aim of this study was to devise and evaluate a novel diagnostic algorithm for ME-NBI in depressed early gastric cancer. Between August, 2007 and May, 2011, 90 patients with a total of 110 depressed gastric lesions were enrolled in the study. A diagnostic algorithm was devised based on ME-NBI microvascular findings: microvascular irregularity and abnormal microvascular patterns (fine network, corkscrew and unclassified patterns). The diagnostic efficiency of the algorithm for gastric cancer and histological grade was assessed by measuring its mean sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy. Furthermore, inter- and intra-observer variation were measured. In the differential diagnosis of gastric cancer from non-cancerous lesions, the mean sensitivity, specificity, PPV, NPV, and accuracy of the diagnostic algorithm were 86.7, 48.0, 94.4, 26.7, and 83.2%, respectively. Furthermore, in the differential diagnosis of undifferentiated adenocarcinoma from differentiated adenocarcinoma, the mean sensitivity, specificity, PPV, NPV, and accuracy of the diagnostic algorithm were 61.6, 86.3, 69.0, 84.8, and 79.1%, respectively. For the ME-NBI final diagnosis using this algorithm, the mean κ values for inter- and intra-observer agreement were 0.50 and 0.77, respectively. In conclusion, the diagnostic algorithm based on ME-NBI microvascular findings was convenient and had high diagnostic accuracy, reliability and reproducibility in the differential diagnosis of depressed gastric lesions. PMID:24649321
Comparative study on the efficiency of some optical methods for artwork diagnostics
NASA Astrophysics Data System (ADS)
Schirripa Spagnolo, Giuseppe; Ambrosini, Dario; Paoletti, Domenica
2001-10-01
Scientific investigation methods are founding their place besides the stylistic-historical study methods in art research works. In particular, optical techniques, transferred from other fields or developed ad hoc, can make a strong contribution to the safeguarding and exploitation of cultural heritage. This paper describes the use of different optical techniques, such as holographic interferometry, decorrelation, shearography and ESPI, in the diagnostics of works of art. A comparison between different methods is obtained by performing tests on specially designed models, prepared using typical techniques and materials. Inside the model structure, a number of defects of known types, form and extension are inserted. The different features of each technique are outlined and a comparison with IR thermography is also carried out.
Research on Thermodynamic Parameters of a Micro-Turbine for Standalone Cogeneration
NASA Astrophysics Data System (ADS)
Chekardovskiy, M. N.; Chekardovskiy, S. M.; Chekardovskaya, I. A.; Mihajlenko, A. I.
2016-10-01
In order to advance the heating and hot water systems in the Russian Federation we need to address the problem of introducing new sources of heat and electric energy. The paper overviews the relationship between the reliability, efficiency and diagnostic maintenance of the GMTU, the studies of rated and operating conditions of the GMTU, the development and improvement of methods for calculating rated and operating thermodynamic and diagnostic parameter of the unit. This resulted in developing a passport of thermodynamic parameters that can be compared to the parameters of the same units when they operate for the purpose of diagnosing their state.
Use of acousto-optic tunable filter in fluorescence imaging endoscopy
NASA Astrophysics Data System (ADS)
Bouhifd, Mounir; Whelan, Maurice; Aprahamian, Marc
2003-10-01
A prototype instrument for fluorescence-based medical diagnostics in vivo is described. The system consists of a rigid endoscope comprising a UV laser-source for fluorescence excitation and a white light source for direct imaging. An acousto-optic tuneable filter (AOTF) is employed as a full-field tuneable bandpass filter. This allows fast continuous or random-access tuning with high filtering efficiency. A study of the diagnostic potential of fluorescence imaging for pancreatitis was conducted on a rat model. In particular, the aim was to detect autofluorescence of endogenous protoporphyrin IX (PpIX) that has been shown to accumulate in early-stage diseased tissue undergoing an inflammatory response.
Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review.
Ibrahim, N; Parsa, A; Hassan, B; van der Stelt, P; Wismeijer, D
2013-01-01
Several dental implant studies have reported that radiographic evaluation of bone quality can aid in reducing implant failure. Bone quality is assessed in terms of its quantity, density, trabecular characteristics and cells. Current imaging modalities vary widely in their efficiency in assessing trabecular structures, especially in a clinical setting. Most are very costly, require an extensive scanning procedure coupled with a high radiation dose and are only partially suitable for patient use. This review examines the current literature regarding diagnostic imaging assessment of trabecular microstructure prior to oral implant placement and suggests cone beam CT as a method of choice for evaluating trabecular bone microstructure.
Monitoring nanoparticle synthesis in a carbon arc discharge environment, in situ
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitrani, James
This work presents experimental and theoretical studies of gas-phase synthesis of fullerenes and carbon nanoparticles in the presence of an atmospheric-pressure, arc discharge plasma. Carbon arc discharges have been used for synthesizing carbon nanotubes for over 25 years, and have the potential for economically synthesizing industrial-scale quantities of fullerenes. However, the efficiency and selectivity of fullerene synthesis with carbon arc discharges are quite low. Optimizing carbon arc discharges for fullerene synthesis requires a thorough understanding of the dynamics behind gas-phase nanoparticle synthesis in the presence of an arc discharge plasma. We built a carbon arc discharge setup to study nanoparticlemore » and fullerene synthesis. The laser-induced incandescence (LII) diagnostic was applied for monitoring nanoparticle synthesis, in situ. The LII diagnostic had previously been applied as a combustion diagnostic for in situ measurements of concentrations and sizes of soot particles in flame environments. Prior to the present study, it had never been applied for studying fullerenes, nor had it been applied to study nanoparticles in the presence of an atmospheric-pressure plasma. Therefore, experiments were designed that allowed for the calibration of the LII diagnostic with research-grade, arc-synthesized soot particles and carbon nanotubes. Additionally, the theory and models underpinning the LII diagnostic were adapted to include the presence of an atmospheric-pressure, arc-discharge plasma. Results presented in this work confirm the ability of the LII diagnostic to measure sizes of arc-synthesized nanoparticles in situ, and show the spatial location of high densities of arc-synthesized nanoparticles with respect to the arc discharge plasma. Determining the spatial location of nanoparticle synthesis and growth is crucial for understanding the background conditions (e.g. background gas temperature, electron densities ...) in which nanoparticles nucleate and grow in the arc discharge environment. Future work would involve combining the LII diagnostic with other laser-based diagnostics (e.g. Rayleigh scattering, laser-induced fluorescence) for a more comprehensive study of gas-phase nanoparticle synthesis and investigating fundamental basic-science questions related to low temperature plasma physics, and laser-nanoparticle interactions.« less
Monitoring Nanoparticle Synthesis in a Carbon Arc Discharge Environment, In Situ
NASA Astrophysics Data System (ADS)
Mitrani, James
This work presents experimental and theoretical studies of gas-phase synthesis of fullerenes and carbon nanoparticles in the presence of an atmospheric-pressure, arc discharge plasma. Carbon arc discharges have been used for synthesizing carbon nanotubes for over 25 years, and have the potential for economically synthesizing industrial-scale quantities of fullerenes. However, the efficiency and selectivity of fullerene synthesis with carbon arc discharges are quite low. Optimizing carbon arc discharges for fullerene synthesis requires a thorough understanding of the dynamics behind gas-phase nanoparticle synthesis in the presence of an arc discharge plasma. We built a carbon arc discharge setup to study nanoparticle and fullerene synthesis. The laser-induced incandescence (LII) diagnostic was applied for monitoring nanoparticle synthesis, in situ. The LII diagnostic had previously been applied as a combustion diagnostic for in situ measurements of concentrations and sizes of soot particles in flame environments. Prior to the present study, it had never been applied for studying fullerenes, nor had it been applied to study nanoparticles in the presence of an atmospheric-pressure plasma. Therefore, experiments were designed that allowed for the calibration of the LII diagnostic with research-grade, arc-synthesized soot particles and carbon nanotubes. Additionally, the theory and models underpinning the LII diagnostic were adapted to include the presence of an atmospheric-pressure, arc-discharge plasma. Results presented in this work confirm the ability of the LII diagnostic to measure sizes of arc-synthesized nanoparticles in situ, and show the spatial location of high densities of arc-synthesized nanoparticles with respect to the arc discharge plasma. Determining the spatial location of nanoparticle synthesis and growth is crucial for understanding the background conditions (e.g. background gas temperature, electron densities ...) in which nanoparticles nucleate and grow in the arc discharge environment. Future work would involve combining the LII diagnostic with other laser-based diagnostics (e.g. Rayleigh scattering, laser-induced fluorescence) for a more comprehensive study of gas-phase nanoparticle synthesis and investigating fundamental basic-science questions related to low temperature plasma physics, and laser-nanoparticle interactions.
Takegami, Kazuki; Hayashi, Hiroaki; Okino, Hiroki; Kimoto, Natsumi; Maehata, Itsumi; Kanazawa, Yuki; Okazaki, Tohru; Hashizume, Takuya; Kobayashi, Ikuo
2016-01-01
For X-ray inspections by way of general X-ray equipment, it is important to measure an entrance-skin dose. Recently, a small optically stimulated luminescence (OSL) dosimeter was made commercially available by Landauer, Inc. The dosimeter does not interfere with the medical images; therefore, it is expected to be a convenient detector for measuring personal exposure doses. In an actual clinical situation, it is assumed that X-rays of different energies will be detected by a dosimeter. For evaluation of the exposure dose measured by a dosimeter, it is necessary to know the energy dependence of the dosimeter. Our aim in this study was to measure the energy dependence of the OSL dosimeter experimentally in the diagnostic X-ray region. Metal samples weighing several grams were irradiated and, in this way, characteristic X-rays having energies ranging from 8 to 85 keV were generated. Using these mono-energetic X-rays, the dosimeter was irradiated. Simultaneously, the fluence of the X-rays was determined with a CdTe detector. The energy-dependent efficiency of the dosimeter was derived from the measured value of the dosimeter and the fluence. Moreover, the energy-dependent efficiency was calculated by Monte-Carlo simulation. The efficiency obtained in the experiment was in good agreement with that of the simulation. In conclusion, our proposed method, in which characteristic X-rays are used, is valuable for measurement of the energy dependence of a small OSL dosimeter in the diagnostic X-ray region.
Diagnostic studies of ion beam formation in inductively coupled plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, Jenee L.
2015-01-01
This dissertation describes a variety of studies focused on the plasma and the ion beam in inductively coupled plasma mass spectrometry (ICP-MS). The ability to use ICP-MS for measurements of trace elements in samples requires the analytes to be efficiently ionized. Updated ionization efficiency tables are discussed for ionization temperatures of 6500 K and 7000 K with an electron density of 1 x 10 15 cm -3. These values are reflective of the current operating parameters of ICP-MS instruments. Calculations are also discussed for doubly charged (M 2+) ion formation, neutral metal oxide (MO) ionization, and metal oxide (MO +)more » ion dissociation for similar plasma temperature values. Ionization efficiency results for neutral MO molecules in the ICP have not been reported previously.« less
Sabbatini, Amber K; Merck, Lisa H; Froemming, Adam T; Vaughan, William; Brown, Michael D; Hess, Erik P; Applegate, Kimberly E; Comfere, Nneka I
2015-12-01
Patient-centered emergency diagnostic imaging relies on efficient communication and multispecialty care coordination to ensure optimal imaging utilization. The construct of the emergency diagnostic imaging care coordination cycle with three main phases (pretest, test, and posttest) provides a useful framework to evaluate care coordination in patient-centered emergency diagnostic imaging. This article summarizes findings reached during the patient-centered outcomes session of the 2015 Academic Emergency Medicine consensus conference "Diagnostic Imaging in the Emergency Department: A Research Agenda to Optimize Utilization." The primary objective was to develop a research agenda focused on 1) defining component parts of the emergency diagnostic imaging care coordination process, 2) identifying gaps in communication that affect emergency diagnostic imaging, and 3) defining optimal methods of communication and multidisciplinary care coordination that ensure patient-centered emergency diagnostic imaging. Prioritized research questions provided the framework to define a research agenda for multidisciplinary care coordination in emergency diagnostic imaging. © 2015 by the Society for Academic Emergency Medicine.
Evaluation of a Diagnostic Encyclopedia Workstation for ovarian pathology.
van Ginneken, A M; Baak, J P; Jansen, W; Smeulders, A W
1990-10-01
The Diagnostic Encyclopedia Workstation (DEW) is a computer system that provides completely integrated pictorial and textual information as reference knowledge in the field of ovarian pathology. The textual component comprises information per diagnosis such as descriptions of macroscopic and microscopic images, clinical signs, and prognosis. In addition, the system offers lists of differential diagnoses and criteria to differentiate among lists of differential diagnoses and criteria to differentiate among them. The present study evaluates to what extent the system influences the diagnostic process in efficiency and outcome. Therefore, two groups of six pathologists each, covering a wide spectrum of experience in ovarian pathology, participated in the evaluation of the DEW. The quality of the resulting diagnoses was statistically analyzed with the Wilcoxon rank sum test with respect to five different viewpoints: classification, morphology, clinical consequences, duration of diagnostic process, and consensus among the participants. The results are discussed and it is concluded that classification and morphology showed better results when books were used. The evaluation experiment was, however, very rigid and negatively biased with respect to the DEW system. Positive aspects of the encyclopedia are the easy access to diagnostic and differential diagnostic information and the large set of illustrations. Insight is acquired with respect to existing bottlenecks and how they may be overcome.
Sohrabi, Mehdi; Parsi, Masoumeh; Sina, Sedigheh
2018-05-17
A diagnostic reference level is an advisory dose level set by a regulatory authority in a country as an efficient criterion for protection of patients from unwanted medical exposure. In computed tomography, the direct dose measurement and data collection methods are commonly applied for determination of diagnostic reference levels. Recently, a new quality-control-based dose survey method was proposed by the authors to simplify the diagnostic reference-level determination using a retrospective quality control database usually available at a regulatory authority in a country. In line with such a development, a prospective dual-purpose quality control dosimetry protocol is proposed for determination of diagnostic reference levels in a country, which can be simply applied by quality control service providers. This new proposed method was applied to five computed tomography scanners in Shiraz, Iran, and diagnostic reference levels for head, abdomen/pelvis, sinus, chest, and lumbar spine examinations were determined. The results were compared to those obtained by the data collection and quality-control-based dose survey methods, carried out in parallel in this study, and were found to agree well within approximately 6%. This is highly acceptable for quality-control-based methods according to International Atomic Energy Agency tolerance levels (±20%).
Wyland, Matthew; Applequist, Lee; Bolowsky, Erin; Klingensmith, Heather; Virag, Isaac
2016-01-01
Background Plantar fasciitis (PF) is the most common cause of heel pain that affects 10% of the general population, whether living an athletic or sedentary lifestyle. The most frequent mechanism of injury is an inflammatory response that is caused by repetitive micro trauma. Many techniques are available to diagnose PF, including the use of ultrasonography (US). Purpose The purpose of this study is to systematically review and appraise previously published articles published between the years 2000 and 2015 that evaluated the effectiveness of using US in the process of diagnosing PF, as compared to alternative diagnostic methods. Methods A total of eight databases were searched to systematically review scholarly (peer reviewed) diagnostic and intervention articles pertaining to the ability of US to diagnose PF. Results Using specific key words the preliminary search yielded 264 articles, 10 of which were deemed relevant for inclusion in the study. Two raters independently scored each article using the 15 point modified QUADAS scale. Discussion Six studies compared the diagnostic efficacy of US to another diagnostic technique to diagnose PF, and four studies focused on comparing baseline assessment of plantar fascia before subsequent intervention. The most notable US outcomes measured were plantar fascia thickness, enthesopathy, and hypoechogenicity. Conclusion US was found to be accurate and reliable compared to alternative reference standards like MRI in the diagnosis of PF. The general advantages of US (e.g. cost efficient, ease of administration, non-invasive, limited contraindications) make it a superior diagnostic modality in the diagnosis of PF. US should be considered in rehabilitation clinics to effectively diagnose PF and to accurately monitor improvement in the disease process following rehabilitation interventions. Level of Evidence 1A PMID:27757279
A Diagnostic Assessment of Evolutionary Multiobjective Optimization for Water Resources Systems
NASA Astrophysics Data System (ADS)
Reed, P.; Hadka, D.; Herman, J.; Kasprzyk, J.; Kollat, J.
2012-04-01
This study contributes a rigorous diagnostic assessment of state-of-the-art multiobjective evolutionary algorithms (MOEAs) and highlights key advances that the water resources field can exploit to better discover the critical tradeoffs constraining our systems. This study provides the most comprehensive diagnostic assessment of MOEAs for water resources to date, exploiting more than 100,000 MOEA runs and trillions of design evaluations. The diagnostic assessment measures the effectiveness, efficiency, reliability, and controllability of ten benchmark MOEAs for a representative suite of water resources applications addressing rainfall-runoff calibration, long-term groundwater monitoring (LTM), and risk-based water supply portfolio planning. The suite of problems encompasses a range of challenging problem properties including (1) many-objective formulations with 4 or more objectives, (2) multi-modality (or false optima), (3) nonlinearity, (4) discreteness, (5) severe constraints, (6) stochastic objectives, and (7) non-separability (also called epistasis). The applications are representative of the dominant problem classes that have shaped the history of MOEAs in water resources and that will be dominant foci in the future. Recommendations are provided for which modern MOEAs should serve as tools and benchmarks in the future water resources literature.
SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, M; Wang, Y; Weng, H
Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less
Diagnostic Efficiency of easyCBM[R] Math: Oregon. Technical Report #1009
ERIC Educational Resources Information Center
Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2010-01-01
The easyCBM[R] assessment system is an online benchmark and progress monitoring assessment system designed for use within a response to intervention framework. Educators using easyCBM[R] are often interested in using the results to predict students' state test performance. In the following technical document, we report diagnostic efficiency…
[Bacterial vaginosis in pregnant women--treatment with clindamycin].
Damianov, L; Damianova, V
2004-01-01
The authors discuss one of the most frequently founded cause of spontaneous abortions and prematurity birth--the bacterial vaginosis. The diagnostics is easy and not expensive. In the complex of health's caries it is necessary to include and the prophylaxis of diagnostics and harmless and efficient treatment with local drug as example "Dalacin V".
ERIC Educational Resources Information Center
Madison, Matthew J.; Bradshaw, Laine P.
2015-01-01
Diagnostic classification models are psychometric models that aim to classify examinees according to their mastery or non-mastery of specified latent characteristics. These models are well-suited for providing diagnostic feedback on educational assessments because of their practical efficiency and increased reliability when compared with other…
Green, Jonathan D; Annunziata, Anthony; Kleiman, Sarah E; Bovin, Michelle J; Harwell, Aaron M; Fox, Annie M L; Black, Shimrit K; Schnurr, Paula P; Holowka, Darren W; Rosen, Raymond C; Keane, Terence M; Marx, Brian P
2017-08-01
Posttraumatic stress disorder (PTSD) diagnostic criteria have been criticized for including symptoms that overlap with commonly comorbid disorders, which critics argue undermines the validity of the diagnosis and inflates psychiatric comorbidity rates. In response, the upcoming 11th edition of the International Classification of Diseases (ICD-11) will offer PTSD diagnostic criteria that are intended to promote diagnostic accuracy. However, diagnostic utility analyses have not yet assessed whether these criteria minimize diagnostic errors. The present study examined the diagnostic utility of each PTSD symptom in the fifth edition of the Diagnostic and Statistical Manual for Mental Disorders (DSM-5) for males and females. Participants were 1,347 individuals enrolled in a longitudinal national registry of returning veterans receiving care at a Department of Veterans Affairs (VA) facility. Doctoral level clinicians assessed all participants using the PTSD module of the Structured Clinical Interview for DSM. Of the 20 symptoms examined, the majority performed in the fair to poor range on test quality indices. Although a few items did perform in the good (or better) range, only half were ICD-11 symptoms. None of the 20 symptoms demonstrated good quality of efficiency. Results demonstrated few sex differences across indices. There were no differences in the proportion of comorbid psychiatric disorders or functional impairment between DSM-5 and ICD-11 criteria. ICD-11 PTSD criteria demonstrate neither greater diagnostic specificity nor reduced rates of comorbidity relative to DSM-5 criteria and, as such, do not perform as intended. Modifications to existing symptoms or new symptoms may improve differential diagnosis. © 2017 Wiley Periodicals, Inc.
A real-time diagnostic and performance monitor for UNIX. M.S. Thesis
NASA Technical Reports Server (NTRS)
Dong, Hongchao
1992-01-01
There are now over one million UNIX sites and the pace at which new installations are added is steadily increasing. Along with this increase, comes a need to develop simple efficient, effective and adaptable ways of simultaneously collecting real-time diagnostic and performance data. This need exists because distributed systems can give rise to complex failure situations that are often un-identifiable with single-machine diagnostic software. The simultaneous collection of error and performance data is also important for research in failure prediction and error/performance studies. This paper introduces a portable method to concurrently collect real-time diagnostic and performance data on a distributed UNIX system. The combined diagnostic/performance data collection is implemented on a distributed multi-computer system using SUN4's as servers. The approach uses existing UNIX system facilities to gather system dependability information such as error and crash reports. In addition, performance data such as CPU utilization, disk usage, I/O transfer rate and network contention is also collected. In the future, the collected data will be used to identify dependability bottlenecks and to analyze the impact of failures on system performance.
Liang, Xiao; Chigerwe, Munashe; Hietala, Sharon K; Crossley, Beate M
2014-06-01
In order to improve the analytic quality of respiratory specimens collected from cattle for nucleic acid-based diagnosis, a study was undertaken to verify realtime PCR efficiency of specimens collected and stabilized on FTA Cards™, filter paper which is treated chemically. Nucleic acids collected using FTA Cards without the need for a cold-chain or special liquid media handling provided realtime PCR results consistent (96.8% agreement, kappa 0.923 [95% CI=0.89-0.96]) with the same specimens collected using traditional viral transport media and shipped on ice using the U.S. Department of Transportation mandated liquid handling requirements. Nucleic acid stabilization on FTA Cards was evaluated over a temperature range (-27 °C to +46 °C) for up to 14 days to mimic environmental conditions for diagnostic sample handling between collection and processing in a routine veterinary laboratory. No significant difference (P≥0.05) was observed in realtime PCR cycle threshold values over the temperature range and time storage conditions for Bovine Viral Diarrhea virus, Bovine Respiratory Syncytial virus, Bovine Coronavirus, and Bovine Herpesvirus I. The four viruses evaluated in the study are associated with Bovine Respiratory Disease Complex where improvements in ease and reliability of specimen collection and shipping would enhance the diagnostic quality of specimens collected in the field, and ultimately improve diagnostic efficiency. Copyright © 2014 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Porcine epidemic diarrhea virus (PEDV) was detected for the first time in US swine in April 2013 and has caused significant economic loss. Obtaining a US PEDV isolate that can grow efficiently in cell culture is critical for PEDV pathogenesis study, diagnostic assays and vaccine development. It was ...
ERIC Educational Resources Information Center
Guy, Laura S.; Poythress, Norman G.; Douglas, Kevin S.; Skeem, Jennifer L.; Edens, John F.
2008-01-01
Antisocial personality disorder (ASPD) is associated with suicide, violence, and risk-taking behavior and can slow response to first-line treatment for Axis I disorders. ASPD may be assessed infrequently because few efficient diagnostic tools are available. This study evaluated 2 promising self-report measures for assessing ASPD--the ASPD scale of…
Nanotechnology-Based Surface Plasmon Resonance Affinity Biosensors for In Vitro Diagnostics
Antiochia, Riccarda; Bollella, Paolo; Favero, Gabriele
2016-01-01
In the last decades, in vitro diagnostic devices (IVDDs) became a very important tool in medicine for an early and correct diagnosis, a proper screening of targeted population, and also assessing the efficiency of a specific therapy. In this review, the most recent developments regarding different configurations of surface plasmon resonance affinity biosensors modified by using several nanostructured materials for in vitro diagnostics are critically discussed. Both assembly and performances of the IVDDs tested in biological samples are reported and compared. PMID:27594884
Clinical Decision Making Following Disasters: Efficient Identification of PTSD Risk in Adolescents
Danielson, Carla Kmett; Cohen, Joseph; Adams, Zachary; Youngstrom, Eric A.; Soltis, Kathryn; Amstadter, Ananda B.; Ruggiero, Kenneth J.
2016-01-01
The present study aimed to utilize a Receiver Operating Characteristic (ROC) approach in order to improve clinical decision-making for adolescents at risk for the development of psychopathology in the aftermath of a natural disaster. Specifically we assessed theoretically-driven individual, interpersonal, and event-related vulnerability factors to determine which indices were most accurate in forecasting PTSD. Furthermore, we aimed to translate these etiological findings by identifying clinical cut-off recommendations for relevant vulnerability factors. Our study consisted of structured phone-based clinical interviews with 2,000 adolescent-parent dyads living within a 5-mile radius of tornados that devastated Joplin, MO, and northern Alabama in Spring 2011. Demographics, tornado incident characteristics, prior trauma, mental health, and family support and conflict were assessed. A subset of youth completed two behavioral assessment tasks online to assess distress tolerance and risk taking behavior. ROC analyses indicated four variables that significantly improved PTSD diagnostic efficiency: Lifetime depression (AUC=.90), trauma history (AUC=.76), social support (AUC=.70), and family conflict (AUC=.72). Youth were 2–3 times more likely to have PTSD if they had elevated scores on any of these variables. Of note, event-related characteristics (e.g., property damage) were not related to PTSD diagnostic status. The present study adds to the literature by making specific recommendations for empirically-based, efficient disaster-related PTSD assessment for adolescents following a natural disaster. Implications for practice and future trauma-related developmental psychopathology research are discussed. PMID:27103002
Clinical Decision-Making Following Disasters: Efficient Identification of PTSD Risk in Adolescents.
Danielson, Carla Kmett; Cohen, Joseph R; Adams, Zachary W; Youngstrom, Eric A; Soltis, Kathryn; Amstadter, Ananda B; Ruggiero, Kenneth J
2017-01-01
The present study aimed to utilize a Receiver Operating Characteristic (ROC) approach in order to improve clinical decision-making for adolescents at risk for the development of psychopathology in the aftermath of a natural disaster. Specifically we assessed theoretically-driven individual, interpersonal, and event-related vulnerability factors to determine which indices were most accurate in forecasting PTSD. Furthermore, we aimed to translate these etiological findings by identifying clinical cut-off recommendations for relevant vulnerability factors. Our study consisted of structured phone-based clinical interviews with 2000 adolescent-parent dyads living within a 5-mile radius of tornados that devastated Joplin, MO, and northern Alabama in Spring 2011. Demographics, tornado incident characteristics, prior trauma, mental health, and family support and conflict were assessed. A subset of youth completed two behavioral assessment tasks online to assess distress tolerance and risk-taking behavior. ROC analyses indicated four variables that significantly improved PTSD diagnostic efficiency: Lifetime depression (AUC = .90), trauma history (AUC = .76), social support (AUC = .70), and family conflict (AUC = .72). Youth were 2-3 times more likely to have PTSD if they had elevated scores on any of these variables. Of note, event-related characteristics (e.g., property damage) were not related to PTSD diagnostic status. The present study adds to the literature by making specific recommendations for empirically-based, efficient disaster-related PTSD assessment for adolescents following a natural disaster. Implications for practice and future trauma-related developmental psychopathology research are discussed.
Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna
2014-03-01
The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA
Ziętkiewicz, Ewa; Rutkiewicz, Ewa; Pogorzelski, Andrzej; Klimek, Barbara; Voelkel, Katarzyna; Witt, Michał
2014-01-01
Cystic fibrosis (CF) is caused by mutations in the cystic fibrosis transmembrane regulator gene (CFTR). In light of the strong allelic heterogeneity and regional specificity of the mutation spectrum, the strategy of molecular diagnostics and counseling in CF requires genetic tests to reflect the frequency profile characteristic for a given population. The goal of the study was to provide an updated comprehensive estimation of the distribution of CFTR mutations in Polish CF patients and to assess the effectiveness of INNOLiPA_CFTR tests in Polish population. The analyzed cohort consisted of 738 patients with the clinically confirmed CF diagnosis, prescreened for molecular defects using INNOLiPA_CFTR panels from Innogenetics. A combined efficiency of INNOLiPA CFTR_19 and CFTR_17_TnUpdate tests was 75.5%; both mutations were detected in 68.2%, and one mutation in 14.8% of the affected individuals. The group composed of all the patients with only one or with no mutation detected (109 and 126 individuals, respectively) was analyzed further using a mutation screening approach, i.e. SSCP/HD (single strand conformational polymorphism/heteroduplex) analysis of PCR products followed by sequencing of the coding sequence. As a result, 53 more mutations were found in 97 patients. The overall efficiency of the CF allele detection was 82.5% (7.0% increase compared to INNOLiPA tests alone). The distribution of the most frequent mutations in Poland was assessed. Most of the mutations repetitively found in Polish patients had been previously described in other European populations. The most frequent mutated allele, F508del, represented 54.5% of Polish CF chromosomes. Another eight mutations had frequencies over 1%, 24 had frequencies between 1 and 0.1%; c.2052-2053insA and c.3468+2_3468+3insT were the most frequent non-INNOLiPA mutations. Mutation distribution described herein is also relevant to the Polish diaspora. Our study also demonstrates that the reported efficiency of mutation detection strongly depends on the diagnostic experience of referring health centers. PMID:24586523
Ziętkiewicz, Ewa; Rutkiewicz, Ewa; Pogorzelski, Andrzej; Klimek, Barbara; Voelkel, Katarzyna; Witt, Michał
2014-01-01
Cystic fibrosis (CF) is caused by mutations in the cystic fibrosis transmembrane regulator gene (CFTR). In light of the strong allelic heterogeneity and regional specificity of the mutation spectrum, the strategy of molecular diagnostics and counseling in CF requires genetic tests to reflect the frequency profile characteristic for a given population. The goal of the study was to provide an updated comprehensive estimation of the distribution of CFTR mutations in Polish CF patients and to assess the effectiveness of INNOLiPA_CFTR tests in Polish population. The analyzed cohort consisted of 738 patients with the clinically confirmed CF diagnosis, prescreened for molecular defects using INNOLiPA_CFTR panels from Innogenetics. A combined efficiency of INNOLiPA CFTR_19 and CFTR_17_TnUpdate tests was 75.5%; both mutations were detected in 68.2%, and one mutation in 14.8% of the affected individuals. The group composed of all the patients with only one or with no mutation detected (109 and 126 individuals, respectively) was analyzed further using a mutation screening approach, i.e. SSCP/HD (single strand conformational polymorphism/heteroduplex) analysis of PCR products followed by sequencing of the coding sequence. As a result, 53 more mutations were found in 97 patients. The overall efficiency of the CF allele detection was 82.5% (7.0% increase compared to INNOLiPA tests alone). The distribution of the most frequent mutations in Poland was assessed. Most of the mutations repetitively found in Polish patients had been previously described in other European populations. The most frequent mutated allele, F508del, represented 54.5% of Polish CF chromosomes. Another eight mutations had frequencies over 1%, 24 had frequencies between 1 and 0.1%; c.2052-2053insA and c.3468+2_3468+3insT were the most frequent non-INNOLiPA mutations. Mutation distribution described herein is also relevant to the Polish diaspora. Our study also demonstrates that the reported efficiency of mutation detection strongly depends on the diagnostic experience of referring health centers.
Overcoming limitations of model-based diagnostic reasoning systems
NASA Technical Reports Server (NTRS)
Holtzblatt, Lester J.; Marcotte, Richard A.; Piazza, Richard L.
1989-01-01
The development of a model-based diagnostic system to overcome the limitations of model-based reasoning systems is discussed. It is noted that model-based reasoning techniques can be used to analyze the failure behavior and diagnosability of system and circuit designs as part of the system process itself. One goal of current research is the development of a diagnostic algorithm which can reason efficiently about large numbers of diagnostic suspects and can handle both combinational and sequential circuits. A second goal is to address the model-creation problem by developing an approach for using design models to construct the GMODS model in an automated fashion.
Tri-city study of Ecstasy use problems: a latent class analysis.
Scheier, Lawrence M; Ben Abdallah, Arbi; Inciardi, James A; Copeland, Jan; Cottler, Linda B
2008-12-01
This study used latent class analysis to examine distinctive subtypes of Ecstasy users based on 24 abuse and dependence symptoms underlying standard DSM-IV criteria. Data came from a three site, population-based, epidemiological study to examine diagnostic nosology for Ecstasy use. Subject inclusion criteria included lifetime Ecstasy use exceeding five times and once in the past year, with participants ranging in age between 16 and 47 years of age from St. Louis, Miami, U.S. and Sydney, Australia. A satisfactory model typified four latent classes representing clearly differentiated diagnostic clusters including: (1) a group of sub-threshold users endorsing few abuse and dependence symptoms (negatives), (2) a group of 'diagnostic orphans' who had characteristic features of dependence for a select group of symptoms (mild dependent), (3) a 'transitional group' mimicking the orphans with regard to their profile of dependence also but reporting some abuse symptoms (moderate dependent), and (4) a 'severe dependent' group with a distinct profile of abuse and dependence symptoms. A multinomial logistic regression model indicated that certain latent classes showed unique associations with external non-diagnostic markers. Controlling for demographic characteristics and lifetime quantity of Ecstasy pill use, criminal behavior and motivational cues for Ecstasy use were the most efficient predictors of cluster membership. This study reinforces the heuristic utility of DSM-IV criteria applied to Ecstasy but with a different collage of symptoms that produced four distinct classes of Ecstasy users.
ERIC Educational Resources Information Center
Klingbeil, David A.; Nelson, Peter M.; Van Norman, Ethan R.; Birr, Chris
2017-01-01
We examined the diagnostic accuracy and efficiency of three approaches to universal screening for reading difficulties using retrospective data from 1,307 students in Grades 3 through 5. School staff collected screening data using the Measures of Academic Progress (MAP), a curriculum-based measure (CBM), and running records (RR). The criterion…
Ehling-Schulz, Monika; Messelhäusser, Ute
2013-01-01
The highly heterogeneous genus Bacillus comprises the largest species group of endospore forming bacteria. Because of their ubiquitous nature, Bacillus spores can enter food production at several stages resulting in significant economic losses and posing a potential risk to consumers due the capacity of certain Bacillus strains for toxin production. In the past, food microbiological diagnostics was focused on the determination of species using conventional culture-based methods, which are still widely used. However, due to the extreme intra-species diversity found in the genus Bacillus, DNA-based identification and typing methods are gaining increasing importance in routine diagnostics. Several studies showed that certain characteristics are rather strain-dependent than species-specific. Therefore, the challenge for current and future Bacillus diagnostics is not only the efficient and accurate identification on species level but also the development of rapid methods to identify strains with specific characteristics (such as stress resistance or spoilage potential), trace contamination sources, and last but not least discriminate potential hazardous strains from non-toxic strains. PMID:23440299
Aptamers: novel diagnostic and therapeutic tools for diabetes mellitus and metabolic diseases.
Hu, Jingping; Ye, Mao; Zhou, Zhiguang
2017-03-01
Diabetes mellitus is one of the most common chronic diseases that threatens human health in worldwide populations. Despite enormous efforts invested in the study of diabetes mellitus, the development of precise diagnoses and treatments for this disease remains difficult due to the limitations of current techniques. Therefore, new methods are currently being developed. Aptamers are oligonucleotides that bind to specific target molecules and have been widely applied as diagnostic and therapeutic tools. In recent years, aptamers have been utilized in the study of diabetes mellitus and metabolic diseases. In this review, we highlight recent developments and new perspectives on aptamers in the field of diabetes mellitus and other metabolic diseases. Aptamers could potentially provide the means for efficient diagnoses and therapies against diabetes mellitus.
Practical Considerations for Clinical PET/MR Imaging.
Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan
2018-01-01
Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2017 Elsevier Inc. All rights reserved.
Portable Diagnostics Technology Assessment for Space Missions. Part 2; Market Survey
NASA Technical Reports Server (NTRS)
Nelson, Emily S.; Chait, Arnon
2010-01-01
A mission to Mars of several years duration requires more demanding standards for all onboard instruments than a 6-month mission to the Moon or the International Space Station. In Part 1, we evaluated generic technologies and suitability to NASA needs. This prior work considered crew safety, device maturity and flightworthiness, resource consumption, and medical value. In Part 2, we continue the study by assessing the current marketplace for reliable Point-of-Care diagnostics. The ultimate goal of this project is to provide a set of objective analytical tools to suggest efficient strategies for reaching specific medical targets for any given space mission as program needs, technological development, and scientific understanding evolve.
Practical Considerations for Clinical PET/MR Imaging.
Galgano, Samuel; Viets, Zachary; Fowler, Kathryn; Gore, Lael; Thomas, John V; McNamara, Michelle; McConathy, Jonathan
2017-05-01
Clinical PET/MR imaging is currently performed at a number of centers around the world as part of routine standard of care. This article focuses on issues and considerations for a clinical PET/MR imaging program, focusing on routine standard-of-care studies. Although local factors influence how clinical PET/MR imaging is implemented, the approaches and considerations described here intend to apply to most clinical programs. PET/MR imaging provides many more options than PET/computed tomography with diagnostic advantages for certain clinical applications but with added complexity. A recurring theme is matching the PET/MR imaging protocol to the clinical application to balance diagnostic accuracy with efficiency. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Saldan, Yosyp R.; Pavlov, Sergii V.; Vovkotrub, Dina V.; Saldan, Yulia Y.; Vassilenko, Valentina B.; Mazur, Nadia I.; Nikolaichuk, Daria V.; Wójcik, Waldemar; Romaniuk, Ryszard; Suleimenov, Batyrbek; Bainazarov, Ulan
2017-08-01
Process of eye tomogram obtaining by means of optical coherent tomography is studied. Stages of idiopathic macula holes formation in the process of eye grounds diagnostics are considered. Main stages of retina pathology progression are determined: Fuzzy logic units for obtaining reliable conclusions regarding the result of diagnosis are developed. By the results of theoretical and practical research system and technique of retinal macular region of the eye state analysis is developed ; application of the system, based on fuzzy logic device, improves the efficiency of eye retina complex.
Usefulness of a Regional Health Care Information System in primary care: a case study.
Maass, Marianne C; Asikainen, Paula; Mäenpää, Tiina; Wanne, Olli; Suominen, Tarja
2008-08-01
The goal of this paper is to describe some benefits and possible cost consequences of computer based access to specialised health care information. A before-after activity analysis regarding 20 diabetic patients' clinical appointments was performed in a Health Centre in Satakunta region in Finland. Cost data, an interview, time-and-motion studies, and flow charts based on modelling were applied. Access to up-to-date diagnostic information reduced redundant clinical re-appointments, repeated tests, and mail orders for missing data. Timely access to diagnostic information brought about several benefits regarding workflow, patient care, and disease management. These benefits resulted in theoretical net cost savings. The study results indicated that Regional Information Systems may be useful tools to support performance and improve efficiency. However, further studies are required in order to verify how the monetary savings would impact the performance of Health Care Units.
MO-F-204-00: Preparing for the ABR Diagnostic and Nuclear Medical Physics Exams
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
MO-F-204-02: Preparing for Part 2 of the ABR Diagnostic Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szczykutowicz, T.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
MO-F-204-03: Preparing for Part 3 of the ABR Diagnostic Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zambelli, J.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
MO-F-204-01: Preparing for Part 1 of the ABR Diagnostic Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKenney, S.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
WE-D-213-00: Preparing for the ABR Diagnostic and Nuclear Medicine Physics Exams
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance ofmore » all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
WE-D-213-01: Preparing for Part 1 of the ABR Diagnostic Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simiele, S.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance ofmore » all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
WE-D-213-03: Preparing for Part 3 of the ABR Diagnostic Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevins, N.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance ofmore » all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
WE-D-213-02: Preparing for Part 2 of the ABR Diagnostic Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zambelli, J.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance ofmore » all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
ERIC Educational Resources Information Center
He, Yunfeng; Du, Xiangyun; Toft, Egon; Zhang, Xingli; Qu, Bo; Shi, Jiannong; Zhang, Huan; Zhang, Hui
2018-01-01
In daily patient-history taking and diagnosis practice, doctors ask questions to gather information from patients and narrow down diagnostic hypotheses. Training medical students to be efficient problem solvers through the use of questioning is therefore important. In this study, the effectiveness of problem-based learning (PBL) and lecture-based…
Comparing Two Types of Diagnostic Items to Evaluate Understanding of Heat and Temperature Concepts
ERIC Educational Resources Information Center
Chu, Hye-Eun; Chandrasegaran, A. L.; Treagust, David F.
2018-01-01
The purpose of this research was to investigate an efficient method to assess year 8 (age 13-14) students' conceptual understanding of heat and temperature concepts. Two different types of instruments were used in this study: Type 1, consisting of multiple-choice items with open-ended justifications; and Type 2, consisting of two-tier…
Duszak, Richard; Silva, Ezequiel; Kim, Angela J; Barr, Robert M; Donovan, William D; Kassing, Pamela; McGinty, Geraldine; Allen, Bibb
2013-09-01
The aim of this study was to quantify potential physician work efficiencies and appropriate multiple procedure payment reductions for different same-session diagnostic imaging studies interpreted by different physicians in the same group practice. Medicare Resource-Based Relative Value Scale data were analyzed to determine the relative contributions of various preservice, intraservice, and postservice physician diagnostic imaging work activities. An expert panel quantified potential duplications in professional work activities when separate examinations were performed during the same session by different physicians within the same group practice. Maximum potential work duplications for various imaging modalities were calculated and compared with those used as the basis of CMS payment policy. No potential intraservice work duplication was identified when different examination interpretations were rendered by different physicians in the same group practice. When multiple interpretations within the same modality were rendered by different physicians, maximum potential duplicated preservice and postservice activities ranged from 5% (radiography, fluoroscopy, and nuclear medicine) to 13.6% (CT). Maximum mean potential duplicated work relative value units ranged from 0.0049 (radiography and fluoroscopy) to 0.0413 (CT). This equates to overall potential total work reductions ranging from 1.39% (nuclear medicine) to 2.73% (CT). Across all modalities, this corresponds to maximum Medicare professional component physician fee reductions of 1.23 ± 0.38% (range, 0.95%-1.87%) for services within the same modality, much less than an order of magnitude smaller than those implemented by CMS. For services from different modalities, potential duplications were too small to quantify. Although potential efficiencies exist in physician preservice and postservice work when same-session, same-modality imaging services are rendered by different physicians in the same group practice, these are relatively minuscule and have been grossly overestimated by current CMS payment policy. Greater transparency and methodologic rigor in government payment policy development are warranted. Copyright © 2013 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Wang, Xin; Li, Zong-Xiao; Wen, Yu-Peng; Chang, Cheng
2018-01-01
To study the value of indoleamine 2,3-dioxygenase (IDO) in the early diagnosis of systemic inflammatory response syndrome (SIRS) after cardiopulmonary bypass in children with congenital heart disease. A total of 90 children with congenital heart disease who underwent cardiopumonary bypass surgery between May 2012 and January 2016 were enrolled. According to the prsence or absence of SIRS after surgery, they were divided into SIRS group (n=43) and control group (n=47). Peripheral blood samples were collected before surgery, during surgery, and after surgery. Serum levels of IDO, C-reactive protein (CRP), and interleukin-6 (IL-6) were measured and compared between the two groups. The receiver operating characteristic (ROC) curve was used to evaluate their diagnostic efficiency. Compared with the control group, the SIRS group had higher serum CRP levels at 72 hours after surgery, higher IL-6 levels during surgery and at 72 hours after surgery, and higher IDO levels at 24 and 72 hours after surgery. IDO had a certain value in the diagnosis of SIRS at 24 hours after surgery with an area under the ROC curve (AUC) of 0.793, a specificity of 100%, and a sensitivity of 58.14%. CRP, IL-6, and IDO had a certain value in the diagnosis of SIRS at 72 hours after surgery. IDO had the highest diagnostic efficiency with an AUC of 0.927, a specificity of 95.74%, and a sensitivity of 76.74% at 72 hours after surgery. IL-6, CRP, and IDO have a certain value in the diagnosis of SIRS after surgery for congenital heart disease, and IDO has a higher diagnostic efficiency. IDO can predict the development of SIRS in children after surgery for congenital heart disease earlier.
Liu, Ting; He, Xiang-ge
2006-05-01
To evaluate the overall diagnostic capabilities of frequency-doubling technology (FDT) in patients of primary glaucoma, with standard automated perimetry (SAP) and/or optic disc appearance as the gold standard. A comprehensive electric search in MEDLINE, EMBASE, Cochrane Library, BIOSIS, Previews, HMIC, IPA, OVID, CNKI, CBMdisc, VIP information, CMCC, CCPD, SSreader and 21dmedia and a manual search in related textbooks, journals, congress articles and their references were performed to identify relevant English and Chinese language articles. Criteria for adaptability were established according to validity criteria for diagnostic research published by the Cochrane Methods Group on Screening and Diagnostic Tests. Quality of the included articles was assessed and relevant materials were extracted for studying. Statistical analysis was performed with Meta Test version 0.6 software. Heterogeneity of the included articles was tested, which was used to select appropriate effect model to calculate pooled weighted sensitivity and specificity. Summary Receiver Operating Characteristic (SROC) curve was established and the area under the curve (AUC) was calculated. Finally, sensitivity analysis was performed. Fifteen English articles (21 studies) of 206 retrieved articles were included in the present study, with a total of 3172 patients. The reported sensitivity of FDT ranged from 0.51 to 1.00, and specificity from 0.58 to 1.00. The pooled weighted sensitivity and specificity for FDT with 95% confidence intervals (95% CI) after correction for standard error were 0.86 (0.80 - 0.90), 0.87 (0.81 - 0.91), respectively. The AUC of SROC was 93.01%. Sensitivity analysis demonstrated no disproportionate influences of individual study. The included articles are of good quality and FDT can be a highly efficient diagnostic test for primary glaucoma based on Meta-analysis. However, a high quality perspective study is still required for further analysis.
Xu, Yan; Liu, Biao; Ding, Fengan; Zhou, Xiaodie; Tu, Pin; Yu, Bo; He, Yan; Huang, Peilin
2017-06-01
Circulating tumor cells (CTCs), isolated as a 'liquid biopsy', may provide important diagnostic and prognostic information. Therefore, rapid, reliable and unbiased detection of CTCs are required for routine clinical analyses. It was demonstrated that negative enrichment, an epithelial marker-independent technique for isolating CTCs, exhibits a better efficiency in the detection of CTCs compared with positive enrichment techniques that only use specific anti-epithelial cell adhesion molecules. However, negative enrichment techniques incur significant cell loss during the isolation procedure, and as it is a method that uses only one type of antibody, it is inherently biased. The detection procedure and identification of cell types also relies on skilled and experienced technicians. In the present study, the detection sensitivity of using negative enrichment and a previously described unbiased detection method was compared. The results revealed that unbiased detection methods may efficiently detect >90% of cancer cells in blood samples containing CTCs. By contrast, only 40-60% of CTCs were detected by negative enrichment. Additionally, CTCs were identified in >65% of patients with stage I/II lung cancer. This simple yet efficient approach may achieve a high level of sensitivity. It demonstrates a potential for the large-scale clinical implementation of CTC-based diagnostic and prognostic strategies.
Diagnostics for the detection and evaluation of laser induced damage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheehan, L.; Kozlowski, M.; Rainer, F.
1995-12-31
The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less
Diagnostics for the detection and evaluation of laser induced damage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheehan, L.; Kozlowski, M.; Rainer, F.
1995-01-03
The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less
Point-of-Care Diagnostics for Niche Applications
Cummins, Brian M.; Ligler, Frances S.; Walker, Glenn M.
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. PMID:26837054
Experimental Study of Ultrasound Contrast Agent Mediated Heat Transfer for Therapeutic Applications
NASA Astrophysics Data System (ADS)
Razansky, D.; Adam, D. R.; Einziger, P. D.
2006-05-01
Ultrasound Contrast Agents (UCA) have been recently suggested as efficient enhancers of ultrasonic power deposition in tissue. The ultrasonic energy absorption by UCA, considered as disadvantageous in diagnostic imaging, might be valuable in therapeutic applications such as targeted hyperthermia or ablation treatments. The current study, based on theoretical predictions, was designed to experimentally measure the dissipation and heating effects of encapsulated UCA (Optison™) in a well-controlled and calibrated environment.
Alternative Surfactants for Improved Efficiency of In Situ Tryptic Proteolysis of Fingermarks
NASA Astrophysics Data System (ADS)
Patel, Ekta; Clench, Malcolm R.; West, Andy; Marshall, Peter S.; Marshall, Nathan; Francese, Simona
2015-06-01
Despite recent improvements to in situ proteolysis strategies, a higher efficiency is still needed to increase both the number of peptides detected and the associated ion intensity, leading to a complete and reliable set of biomarkers for diagnostic or prognostic purposes. In the study presented here, an extract of a systematic study is illustrated investigating a range of surfactants assisting trypsin proteolytic activity. Method development was trialled on fingermarks; this specimen results from a transfer of sweat from an individual's fingertip to a surface upon contact. As sweat carries a plethora of biomolecules, including peptides and proteins, fingermarks are, potentially, a very valuable specimen for non-invasive prognostic or diagnostic screening. A recent study has demonstrated the opportunity to quickly detect peptides and small proteins in fingermarks using Matrix Assisted Laser Desorption Ionization Mass Spectrometry Profiling (MALDI MSP). However, intact detection bears low sensitivity and does not allow species identification; therefore, a shotgun proteomic approach was employed involving in situ proteolysis. Data demonstrate that in fingermarks, further improvements to the existing method can be achieved using MEGA-8 as surfactant in higher percentages as well as combinations of different detergents. Also, for the first time, Rapigest SF, normally used in solution digestions, has been shown to successfully work also for in situ proteolysis.
Huang, Ziwei; Gengenbach, Thomas; Tian, Junfei; Shen, Wei; Garnier, Gil
2018-01-01
Paper and cellulosic films are used in many designs of low-cost diagnostics such as paper-based blood grouping devices. A major issue limiting their commercialization is the short stability of the functional biomolecules. To address this problem, the effect of relative humidity (RH) and bovine serum albumin (BSA) on the antibody bioactivity and the surface chemical composition of a paper blood typing biodiagnostic were studied. An IgM blood typing antibody was physisorbed from solution onto paper - with or without BSA pretreatment, and aged for periods up to 9 weeks under various conditions with a series of RH. The blood typing efficiency of the antibodies and the substrate surface chemical composition were analyzed by image analysis and X-ray photoelectron spectroscopy (XPS), respectively. This study tests two hypotheses. The first is that the hydroxyl groups in paper promote antibody denaturation on paper; the second hypothesis is that proteins such as BSA can partially block the hydroxyl groups within paper, thus preserving antibody bioactivity. Results show that high RH is detrimental to antibody longevity on paper, while BSA can block hydroxyl groups and prolong antibody longevity by almost an order of magnitude-regardless of humidity. This study opens up new engineering concepts to develop robust and marketable paper diagnostics. The simplest is to store paper and antibody based diagnostics in moisture proof packages.
NASA Astrophysics Data System (ADS)
Huang, Ziwei; Gengenbach, Thomas; Tian, Junfei; Shen, Wei; Garnier, Gil
2018-05-01
Paper and cellulosic films are used in many designs of low-cost diagnostics such as paper-based blood grouping devices. A major issue limiting their commercialization is the short stability of the functional biomolecules. To address this problem, the effect of relative humidity (RH) and bovine serum albumin (BSA) on the antibody bioactivity and the surface chemical composition of a paper blood typing biodiagnostic were studied. An IgM blood typing antibody was physisorbed from solution onto paper - with or without BSA pretreatment, and aged for periods up to 9 weeks at room temperature and under different RH conditions. The blood typing efficiency of the antibodies and the substrate surface chemical composition were analyzed by image analysis and X-ray photoelectron spectroscopy (XPS), respectively. This study tests two hypotheses. The first is that the hydroxyl groups in paper promote antibody denaturation on paper; the second hypothesis is that proteins such as BSA can partially block the hydroxyl groups with paper, thus preserving antibody bioactivity. Results show that high RH is detrimental to antibody longevity on paper, while BSA can block hydroxyl groups and prolong antibody longevity by almost an order of magnitude – regardless of humidity. This study opens up new engineering concepts to develop robust and marketable paper diagnostics. The simplest is to store paper and antibody based diagnostics in moisture proof packages.
Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.
Alagrund, Katariina; Orpana, Arto K
2014-01-01
The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.
Attention in the real world: toward understanding its neural basis
Peelen, Marius V.; Kastner, Sabine
2016-01-01
The efficient selection of behaviorally relevant objects from cluttered environments supports our everyday goals. Attentional selection has typically been studied in search tasks involving artificial and simplified displays. Although these studies have revealed important basic principles of attention, they do not explain how the brain efficiently selects familiar objects in complex and meaningful real-world scenes. Findings from recent neuroimaging studies indicate that real-world search is mediated by ‘what’ and ‘where’ attentional templates that are implemented in high-level visual cortex. These templates represent target-diagnostic properties and likely target locations, respectively, and are shaped by object familiarity, scene context, and memory. We propose a framework for real-world search that incorporates these recent findings and specifies directions for future study. PMID:24630872
Nokhbatolfoghahaie, Hanieh; Alikhasi, Marzieh; Chiniforush, Nasim; Khoei, Farzaneh; Safavi, Nassimeh; Yaghoub Zadeh, Behnoush
2013-01-01
Introduction: Today the prevalence of teeth decays has considerably decreased. Related organizations and institutions mention several reasons for it such as improvement of decay diagnostic equipment and tools which are even capable of detecting caries in their initial stages. This resulted in reduction of costs for patients and remarkable increase in teeth life span. There are many methods for decay diagnostic, like: visual and radiographic methods, devices with fluorescence such as Quantitative light-induced fluorescence (QLF), Vista proof, Laser fluorescence (LF or DIAGNOdent), Fluorescence Camera (FC) and Digital radiography. Although DIAGNOdent is considered a valuable device for decay diagnostic ,there are concerns regarding its efficacy and accuracy. Considering the sensitivity of decaydiagnosis and the exorbitant annual expenses supported by government and people for caries treatment, finding the best method for early caries detection is of the most importance. Numerous studies were performed to compare different diagnostic methods with conflicting results. The objective of this study is a comparative review of the efficiency of DIAGNOdent in comparison to visual methods and radiographic methods in the diagnostic of teeth occlusal surfaces. Methods: Search of PubMed, Google Scholar electronic resources was performed in order to find clinical trials in English in the period between 1998 and 2013. Full texts of only 35 articles were available. Conclusion: Considering the sensitivity and specificity reported in the different studies, it seems that DIAGNOdent is an appropriate modality for caries detection as a complementary method beside other methods and its use alone to obtain treatment plan is not enough. PMID:25606325
Davatzikos, Christos; Rathore, Saima; Bakas, Spyridon; Pati, Sarthak; Bergman, Mark; Kalarot, Ratheesh; Sridharan, Patmaa; Gastounioti, Aimilia; Jahani, Nariman; Cohen, Eric; Akbari, Hamed; Tunc, Birkan; Doshi, Jimit; Parker, Drew; Hsieh, Michael; Sotiras, Aristeidis; Li, Hongming; Ou, Yangming; Doot, Robert K; Bilello, Michel; Fan, Yong; Shinohara, Russell T; Yushkevich, Paul; Verma, Ragini; Kontos, Despina
2018-01-01
The growth of multiparametric imaging protocols has paved the way for quantitative imaging phenotypes that predict treatment response and clinical outcome, reflect underlying cancer molecular characteristics and spatiotemporal heterogeneity, and can guide personalized treatment planning. This growth has underlined the need for efficient quantitative analytics to derive high-dimensional imaging signatures of diagnostic and predictive value in this emerging era of integrated precision diagnostics. This paper presents cancer imaging phenomics toolkit (CaPTk), a new and dynamically growing software platform for analysis of radiographic images of cancer, currently focusing on brain, breast, and lung cancer. CaPTk leverages the value of quantitative imaging analytics along with machine learning to derive phenotypic imaging signatures, based on two-level functionality. First, image analysis algorithms are used to extract comprehensive panels of diverse and complementary features, such as multiparametric intensity histogram distributions, texture, shape, kinetics, connectomics, and spatial patterns. At the second level, these quantitative imaging signatures are fed into multivariate machine learning models to produce diagnostic, prognostic, and predictive biomarkers. Results from clinical studies in three areas are shown: (i) computational neuro-oncology of brain gliomas for precision diagnostics, prediction of outcome, and treatment planning; (ii) prediction of treatment response for breast and lung cancer, and (iii) risk assessment for breast cancer.
Feigning combat-related posttraumatic stress disorder on the personality assessment inventory.
Calhoun, P S; Earnst, K S; Tucker, D D; Kirby, A C; Beckham, J C
2000-10-01
This study examined whether individuals who were instructed on the Diagnostic and Statistical Manual of Mental Disorders (4th ed. [DSM-IV]; American Psychiatric Association, 1994) criteria for posttraumatic stress disorder (PTSD) could feign PTSD on the Personality Assessment Inventory (PAI; Morey, 1991). The study also investigated whether PAI indexes of symptom exaggeration, the Negative Impression Management (NIM) scale and the Malingering index, could identify individuals feigning PTSD. The diagnostic rule for PTSD (Morey, 1991, 1996) was applied to the profiles of a group of 23 veterans with combat-related PTSD and 23 male undergraduates instructed to malinger PTSD. Seventy percent of the student malingerers produced profiles that received diagnostic consideration for PTSD. The NIM cutting score (> or = 8) was highly effective in detecting simulation of PTSD but resulted in the misclassification of a large number of true PTSD cases. There were no significant differences in the overall efficiency of the test with various validity criteria. We discuss the implications of these findings for the use of the PAI in the diagnosis of combat-related PTSD.
Doherty, Brenda; Csáki, Andrea; Thiele, Matthias; Zeisberger, Matthias; Schwuchow, Anka; Kobelke, Jens; Fritzsche, Wolfgang; Schmidt, Markus A
2017-02-01
Detecting small quantities of specific target molecules is of major importance within bioanalytics for efficient disease diagnostics. One promising sensing approach relies on combining plasmonically-active waveguides with microfluidics yielding an easy-to-use sensing platform. Here we introduce suspended-core fibres containing immobilised plasmonic nanoparticles surrounding the guiding core as a concept for an entirely integrated optofluidic platform for efficient refractive index sensing. Due to the extremely small optical core and the large adjacent microfluidic channels, over two orders of magnitude of nanoparticle coverage densities have been accessed with millimetre-long sample lengths showing refractive index sensitivities of 170 nm/RIU for aqueous analytes where the fibre interior is functionalised by gold nanospheres. Our concept represents a fully integrated optofluidic sensing system demanding small sample volumes and allowing for real-time analyte monitoring, both of which are highly relevant within invasive bioanalytics, particularly within molecular disease diagnostics and environmental science.
Fung, Monica; Kim, Jane; Marty, Francisco M; Schwarzinger, Michaël; Koo, Sophia
2015-01-01
Invasive fungal disease (IFD) causes significant morbidity and mortality in hematologic malignancy patients with high-risk febrile neutropenia (FN). These patients therefore often receive empirical antifungal therapy. Diagnostic test-guided pre-emptive antifungal therapy has been evaluated as an alternative treatment strategy in these patients. We conducted an electronic search for literature comparing empirical versus pre-emptive antifungal strategies in FN among adult hematologic malignancy patients. We systematically reviewed 9 studies, including randomized-controlled trials, cohort studies, and feasibility studies. Random and fixed-effect models were used to generate pooled relative risk estimates of IFD detection, IFD-related mortality, overall mortality, and rates and duration of antifungal therapy. Heterogeneity was measured via Cochran's Q test, I2 statistic, and between study τ2. Incorporating these parameters and direct costs of drugs and diagnostic testing, we constructed a comparative costing model for the two strategies. We conducted probabilistic sensitivity analysis on pooled estimates and one-way sensitivity analyses on other key parameters with uncertain estimates. Nine published studies met inclusion criteria. Compared to empirical antifungal therapy, pre-emptive strategies were associated with significantly lower antifungal exposure (RR 0.48, 95% CI 0.27-0.85) and duration without an increase in IFD-related mortality (RR 0.82, 95% CI 0.36-1.87) or overall mortality (RR 0.95, 95% CI 0.46-1.99). The pre-emptive strategy cost $324 less (95% credible interval -$291.88 to $418.65 pre-emptive compared to empirical) than the empirical approach per FN episode. However, the cost difference was influenced by relatively small changes in costs of antifungal therapy and diagnostic testing. Compared to empirical antifungal therapy, pre-emptive antifungal therapy in patients with high-risk FN may decrease antifungal use without increasing mortality. We demonstrate a state of economic equipoise between empirical and diagnostic-directed pre-emptive antifungal treatment strategies, influenced by small changes in cost of antifungal therapy and diagnostic testing, in the current literature. This work emphasizes the need for optimization of existing fungal diagnostic strategies, development of more efficient diagnostic strategies, and less toxic and more cost-effective antifungals.
[Waist-to-height ratio is an indicator of metabolic risk in children].
Valle-Leal, Jaime; Abundis-Castro, Leticia; Hernández-Escareño, Juan; Flores-Rubio, Salvador
2016-01-01
Abdominal fat, particularly visceral, is associated with a high risk of metabolic complications. The waist-height ratio (WHtR) is used to assess abdominal fat in individuals of all ages. To determine the ability of the waist-to-height ratio to detect metabolic risk in mexican schoolchildren. A study was conducted on children between 6 and 12 years. Obesity was diagnosed as a body mass index (BMI) ≥ 85th percentile, and an ICE ≥0.5 was considered abdominal obesity. Blood levels of glucose, cholesterol and triglycerides were measured. The sensitivity, specificity, positive predictive and negative value, area under curve, the positive likelihood ratio and negative likelihood ratio of the WHtR and BMI were calculated in order to identify metabolic alterations. WHtR and BMI were compared to determine which had the best diagnostic efficiency. Of the 223 children included in the study, 51 had hypertriglyceridaemia, 27 with hypercholesterolaemia, and 9 with hyperglycaemia. On comparing the diagnostic efficiency of WHtR with that of BMI, there was a sensitivity of 100% vs. 56% for hyperglycaemia, 93 vs. 70% for cholesterol, and 76 vs. 59% for hypertriglyceridaemia. The specificity, negative predictive value, positive predictive value, positive likelihood ratio, negative likelihood ratio, and area under curve were also higher for WHtR. The WHtR is a more efficient indicator than BMI in identifying metabolic risk in mexican school-age. Copyright © 2015 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.
Nygren, David; Isaksson, Arvid Lissel
2014-02-04
During the last decade much progress has been made in reducing malaria transmission in Macha, Southern Province, Zambia. Introduction of artemisinin combination therapies as well as mass screenings of asymptomatic carriers is believed to have contributed the most. When an endemic malaria situation is moving towards a non-endemic situation the resident population loses acquired immunity and therefore active case detection and efficient surveillance is crucial to prevent epidemic outbreaks. Our purpose was to evaluate the impact of cell phone surveillance and geographical information systems on malaria control in Macha. Furthermore, it evaluates what screening and treatment of asymptomatic carriers and implementation of rapid diagnostic tests in rural health care has led to. Ten in-depth semi-structured interviews, field observations and data collection were performed at the Macha Research Trust and at surrounding rural health centers. This qualitative method was inspired by rapid assessment procedure. The cell phone surveillance has been easily integrated in health care, and its integration with Geographical Information Systems has provided the ability to follow malaria transmission on a weekly basis. In addition, active case detection of asymptomatic carriers has been fruitful, which is reflected in it soon being applied nationwide. Furthermore, rapid diagnostic tests have provided rural health centers with reliable malaria diagnostics, thereby decreasing excessive malaria treatments and selection for drug resistance. This report reflects the importance of asymptomatic carriers in targeting malaria elimination, as well as development of effective surveillance systems when transmission decreases. Such an approach would be cost-efficient in the long run through positive effects in reduced child mortality and relief in health care.
An intelligent remote control system for ECEI on EAST
NASA Astrophysics Data System (ADS)
Chen, Dongxu; Zhu, Yilun; Zhao, Zhenling; Qu, Chengming; Liao, Wang; Xie, Jinlin; Liu, Wandong
2017-08-01
An intelligent remote control system based on a power distribution unit (PDU) and Arduino has been designed for the electron cyclotron emission imaging (ECEI) system on Experimental Advanced Superconducting Tokamak (EAST). This intelligent system has three major functions: ECEI system reboot, measurement region adjustment and signal amplitude optimization. The observation region of ECEI can be modified for different physics proposals by remotely tuning the optical and electronics systems. Via the remote adjustment of the attenuation level, the ECEI intermediate frequency signal amplitude can be efficiently optimized. The remote control system provides a feasible and reliable solution for the improvement of signal quality and the efficiency of the ECEI diagnostic system, which is also valuable for other diagnostic systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demkin, V. P.; Melnichuk, S. V.; Demkin, O. V.
The optical and electrophysical characteristics of the nonequilibrium low-temperature plasma formed by a low-current nonsteady-state plasmatron are experimentally investigated in the present work. It is demonstrated that experimental data on the optical diagnostics of the plasma jet can provide a basis for the construction of a self-consistent physical and mathematical plasma model and for the creation of plasma sources with controllable electrophysical parameters intended for the generation of the required concentration of active particles. Results of spectroscopic diagnostics of plasma of the low-current nonsteady-state plasmatron confirm that the given source is efficient for the generation of charged particles and short-wavelengthmore » radiation—important plasma components for biomedical problems of an increase in the efficiency of treatment of biological tissues by charged particles. Measurement of the spatial distribution of the plasma jet potential by the probe method has demonstrated that a negative space charge is formed in the plasma jet possibly due to the formation of electronegative oxygen ions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuznetsov, A. P., E-mail: APKuznetsov@mephi.ru; Buzinskij, O. I.; Gubsky, K. L.
A set of optical diagnostics is expected for measuring the plasma characteristics in ITER. Optical elements located inside discharge chambers are exposed to an intense radiation load, sputtering due to collisions with energetic atoms formed in the charge transfer processes, and contamination due to recondensation of materials sputtered from different parts of the construction of the chamber. Removing the films of the sputtered materials from the mirrors with the aid of pulsed laser radiation is an efficient cleaning method enabling recovery of the optical properties of the mirrors. In this work, we studied the efficiency of removal of metal oxidemore » films by pulsed radiation of a fiber laser. Optimization of the laser cleaning conditions was carried out on samples representing metal substrates polished with optical quality with deposition of films on them imitating the chemical composition and conditions expected in ITER. It is shown that, by a proper selection of modes of radiation exposure to the surface with a deposited film, it is feasible to restore the original high reflection characteristics of optical elements.« less
gCUP: rapid GPU-based HIV-1 co-receptor usage prediction for next-generation sequencing.
Olejnik, Michael; Steuwer, Michel; Gorlatch, Sergei; Heider, Dominik
2014-11-15
Next-generation sequencing (NGS) has a large potential in HIV diagnostics, and genotypic prediction models have been developed and successfully tested in the recent years. However, albeit being highly accurate, these computational models lack computational efficiency to reach their full potential. In this study, we demonstrate the use of graphics processing units (GPUs) in combination with a computational prediction model for HIV tropism. Our new model named gCUP, parallelized and optimized for GPU, is highly accurate and can classify >175 000 sequences per second on an NVIDIA GeForce GTX 460. The computational efficiency of our new model is the next step to enable NGS technologies to reach clinical significance in HIV diagnostics. Moreover, our approach is not limited to HIV tropism prediction, but can also be easily adapted to other settings, e.g. drug resistance prediction. The source code can be downloaded at http://www.heiderlab.de d.heider@wz-straubing.de. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Rutherford, Marion; Burns, Morag; Gray, Duncan; Bremner, Lynne; Clegg, Sarah; Russell, Lucy; Smith, Charlie; O'Hare, Anne
2018-05-01
The 'autism diagnosis crisis' and long waiting times for assessment are as yet unresolved, leading to undue stress and limiting access to effective support. There is therefore a significant need for evidence to support practitioners in the development of efficient services, delivering acceptable waiting times and effectively meeting guideline standards. This study reports statistically significant reductions in waiting times for autism diagnostic assessment following a children's health service improvement programme. The average wait between referral and first appointment reduced from 14.2 to 10.4 weeks (t(21) = 4.3, p < 0.05) and between referral and diagnosis shared, reduced from 270 to 122.5 days, (t(20) = 5.5, p < 0.05). The proportion of girls identified increased from 5.6 to 2.7:1. Methods reported include: local improvement action planning; evidence based pathways; systematic clinical data gathering and a training plan. This is a highly significant finding for many health services wrestling with the challenges of demand and capacity for autism diagnosis and assessment.
An Efficient Model-based Diagnosis Engine for Hybrid Systems Using Structural Model Decomposition
NASA Technical Reports Server (NTRS)
Bregon, Anibal; Narasimhan, Sriram; Roychoudhury, Indranil; Daigle, Matthew; Pulido, Belarmino
2013-01-01
Complex hybrid systems are present in a large range of engineering applications, like mechanical systems, electrical circuits, or embedded computation systems. The behavior of these systems is made up of continuous and discrete event dynamics that increase the difficulties for accurate and timely online fault diagnosis. The Hybrid Diagnosis Engine (HyDE) offers flexibility to the diagnosis application designer to choose the modeling paradigm and the reasoning algorithms. The HyDE architecture supports the use of multiple modeling paradigms at the component and system level. However, HyDE faces some problems regarding performance in terms of complexity and time. Our focus in this paper is on developing efficient model-based methodologies for online fault diagnosis in complex hybrid systems. To do this, we propose a diagnosis framework where structural model decomposition is integrated within the HyDE diagnosis framework to reduce the computational complexity associated with the fault diagnosis of hybrid systems. As a case study, we apply our approach to a diagnostic testbed, the Advanced Diagnostics and Prognostics Testbed (ADAPT), using real data.
Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar
2012-11-26
HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.
2012-01-01
Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful. PMID:23181517
ERIC Educational Resources Information Center
Pfeiffer, Steven I.; Jarosewich, Tania
2007-01-01
This study analyzes the standardization sample of a new teacher rating scale designed to assist in the identification of gifted students. The Gifted Rating Scales-School Form (GRS-S) is based on a multidimensional model of giftedness. Results indicate no age or race/ethnicity differences on any of the scales and small but significant differences…
Rarefied flow diagnostics using pulsed high-current electron beams
NASA Technical Reports Server (NTRS)
Wojcik, Radoslaw M.; Schilling, John H.; Erwin, Daniel A.
1990-01-01
The use of high-current short-pulse electron beams in low-density gas flow diagnostics is introduced. Efficient beam propagation is demonstrated for pressure up to 300 microns. The beams, generated by low-pressure pseudospark discharges in helium, provide extremely high fluorescence levels, allowing time-resolved visualization in high-background environments. The fluorescence signal frequency is species-dependent, allowing instantaneous visualization of mixing flowfields.
Do international rotations make surgical residents more resource-efficient? A preliminary study.
Oliphant, Jason L; Ruhlandt, Ronell R; Sherman, Stanley R; Schlatter, Marc G; Green, Joel A
2012-01-01
Interest in international surgery among general surgery residents in the United States has been shown in several publications. Several general surgery residency programs have reported their experiences with international surgery rotations (ISRs). Learning to use limited resources more efficiently is often cited as a benefit of such rotations. We hypothesized that general surgery residents become more resource efficient after they have completed an ISR. Laboratory, radiologic, and diagnostic studies ordered on 2900 patients by 21 general surgery residents over 65 months at a single institution were analyzed retrospectively. The patient populations they wrote orders on were assessed for similarity in age, gender, and diagnoses. The outcomes in those patient populations were assessed by duration of stay and in-hospital mortality. Six (29%) of these residents (ISR residents) completed a 1-month ISR during their third year of residency. Their orders were compared with their classmates who did not participate in an ISR (NISR residents). The results were compared between the 2 cohorts from both before and after their international rotations. An analysis focused on comparing the changes from pre-ISR to post-ISR. A survey was also sent after objective data were collected to all residents and alumni involved in the study to assess their subjective perception of changes in their resource efficiency and to characterize their ISRs. Patient populations were similar in terms of demographics and diagnoses. ISR residents generated an average of $122 less in orders per patient per month after their ISR compared with before. NISR residents generated an average of $338 more in orders per patient per month after the ISRs compared with before (p = 0.04). Pre-ISR order charges were statistically similar. Similar results were observed when radiologic/diagnostic study orders were analyzed independently. Differences in outcomes were statistically insignificant. The survey revealed that most of the ISR residents perceived that their attitude toward ordering tests and laboratories was influenced greatly by their ISR, and all the ISR residents perceived that they became more resource efficient than their peers after their ISRs. These preliminary findings seem to indicate increased resource efficiency among general surgery residents who completed an ISR. However, the sample size of residents was small, and we could not establish conclusively a causal relationship to their ISRs. A more extensive study is needed if reliable conclusions are to be drawn regarding the effect of ISRs on the resource efficiency of residents. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Point-of-care diagnostics for niche applications.
Cummins, Brian M; Ligler, Frances S; Walker, Glenn M
2016-01-01
Point-of-care or point-of-use diagnostics are analytical devices that provide clinically relevant information without the need for a core clinical laboratory. In this review we define point-of-care diagnostics as portable versions of assays performed in a traditional clinical chemistry laboratory. This review discusses five areas relevant to human and animal health where increased attention could produce significant impact: veterinary medicine, space travel, sports medicine, emergency medicine, and operating room efficiency. For each of these areas, clinical need, available commercial products, and ongoing research into new devices are highlighted. Copyright © 2016 Elsevier Inc. All rights reserved.
Modifying physician behavior to improve cost-efficiency in safety-net ambulatory settings.
Borkowski, Nancy; Gumus, Gulcin; Deckard, Gloria J
2013-01-01
Change interventions in one form or another are viewed as important tools to reduce variation in medical services, reduce costs, and improve quality of care. With the current focus on efficient resource use, the successful design and implementation of change strategies are of utmost importance for health care managers. We present a case study in which macro and micro level change strategies were used to modify primary care physicians' practice patterns of prescribing diagnostic services in a safety-net's ambulatory clinics. The findings suggest that health care managers using evidence-based strategies can create a practice environment that reduces barriers and facilitates change.
The Theory about CD-CAT Based on FCA and Its Application
ERIC Educational Resources Information Center
Shuqun, Yang; Shuliang, Ding; Zhiqiang, Yao
2009-01-01
Cognitive diagnosis (CD) plays an important role in intelligent tutoring system. Computerized adaptive testing (CAT) is adaptive, fair, and efficient, which is suitable to large-scale examination. Traditional cognitive diagnostic test needs quite large number of items, the efficient and tailored CAT could be a remedy for it, so the CAT with…
Rocket engine exhaust plume diagnostics and health monitoring/management during ground testing
NASA Technical Reports Server (NTRS)
Chenevert, D. J.; Meeks, G. R.; Woods, E. G.; Huseonica, H. F.
1992-01-01
The current status of a rocket exhaust plume diagnostics program sponsored by NASA is reviewed. The near-term objective of the program is to enhance test operation efficiency and to provide for safe cutoff of rocket engines prior to incipient failure, thereby avoiding the destruction of the engine and the test complex and preventing delays in the national space program. NASA programs that will benefit from the nonintrusive remote sensed rocket plume diagnostics and related vehicle health management and nonintrusive measurement program are Space Shuttle Main Engine, National Launch System, National Aero-Space Plane, Space Exploration Initiative, Advanced Solid Rocket Motor, and Space Station Freedom. The role of emission spectrometry and other types of remote sensing in rocket plume diagnostics is discussed.
Bouwman, Machtelt G; Teunissen, Quirine G A; Wijburg, Frits A; Linthorst, Gabor E
2010-08-01
The expansion of the internet has resulted in widespread availability of medical information for both patients and physicians. People increasingly spend time on the internet searching for an explanation, diagnosis or treatment for their symptoms. Regarding rare diseases, the use of the internet may be an important tool in the diagnostic process. The authors present two cases in which concerned parents made a correct diagnosis of a lysosomal storage disorder in their child by searching the internet after a long doctor's delay. These cases illustrate the utility of publicly available internet search engines in diagnosing rare disorders and in addition illustrate the lengthy diagnostic odyssey which is common in these disorders.
NASA Astrophysics Data System (ADS)
Li, Shaoxin; Li, Linfang; Zeng, Qiuyao; Zhang, Yanjiao; Guo, Zhouyi; Liu, Zhiming; Jin, Mei; Su, Chengkang; Lin, Lin; Xu, Junfa; Liu, Songhao
2015-05-01
This study aims to characterize and classify serum surface-enhanced Raman spectroscopy (SERS) spectra between bladder cancer patients and normal volunteers by genetic algorithms (GAs) combined with linear discriminate analysis (LDA). Two group serum SERS spectra excited with nanoparticles are collected from healthy volunteers (n = 36) and bladder cancer patients (n = 55). Six diagnostic Raman bands in the regions of 481-486, 682-687, 1018-1034, 1313-1323, 1450-1459 and 1582-1587 cm-1 related to proteins, nucleic acids and lipids are picked out with the GAs and LDA. By the diagnostic models built with the identified six Raman bands, the improved diagnostic sensitivity of 90.9% and specificity of 100% were acquired for classifying bladder cancer patients from normal serum SERS spectra. The results are superior to the sensitivity of 74.6% and specificity of 97.2% obtained with principal component analysis by the same serum SERS spectra dataset. Receiver operating characteristic (ROC) curves further confirmed the efficiency of diagnostic algorithm based on GA-LDA technique. This exploratory work demonstrates that the serum SERS associated with GA-LDA technique has enormous potential to characterize and non-invasively detect bladder cancer through peripheral blood.
Falkum, Erik; Pedersen, Geir; Karterud, Sigmund
2009-01-01
This article examines reliability and validity aspects of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) paranoid personality disorder (PPD) diagnosis. Patients with personality disorders (n = 930) from the Norwegian network of psychotherapeutic day hospitals, of which 114 had PPD, were included in the study. Frequency distribution, chi(2), correlations, reliability statistics, exploratory, and confirmatory factor analyses were performed. The distribution of PPD criteria revealed no distinct boundary between patients with and without PPD. Diagnostic category membership was obtained in 37 of 64 theoretically possible ways. The PPD criteria formed a separate factor in a principal component analysis, whereas a confirmatory factor analysis indicated that the DSM-IV PPD construct consists of 2 separate dimensions as follows: suspiciousness and hostility. The reliability of the unitary PPD scale was only 0.70, probably partly due to the apparent 2-dimensionality of the construct. Persistent unwarranted doubts about the loyalty of friends had the highest diagnostic efficiency, whereas unwarranted accusations of infidelity of partner had particularly poor indicator properties. The reliability and validity of the unitary PPD construct may be questioned. The 2-dimensional PPD model should be further explored.
van Es, N; van der Hulle, T; van Es, J; den Exter, P L; Douma, R A; Goekoop, R J; Mos, I C M; Garcia, J G; Kamphuisen, P W; Huisman, M V; Klok, F A; Büller, H R; Bossuyt, P M
2016-04-01
Among patients with clinically suspected pulmonary embolism (PE), imaging and anticoagulant treatment can be safely withheld in approximately one-third of patients based on the combination of a "PE unlikely" Wells score and a D-dimer below the age-adjusted threshold. The clinical utility of this diagnostic approach in cancer patients is less clear. To evaluate the efficiency and failure rate of the original and simplified Wells rules in combination with age-adjusted D-dimer testing in patients with active cancer. Individual patient data were used from 6 large prospective studies in which the diagnostic management of PE was guided by the original Wells rule and D-dimer testing. Study physicians classified patients as having active cancer if they had new, recurrent, or progressive cancer (excluding basal-cell or squamous-cell skin carcinoma), or cancer requiring treatment in the last 6 months. We evaluated the dichotomous Wells rule and its simplified version (Table). The efficiency of the algorithm was defined as the proportion of patients with a "PE unlikely" Wells score and a negative age-adjusted D-dimer, defined by a D-dimer below the threshold of a patient's age times 10 μg/L in patients aged ≥51 years. A diagnostic failure was defined as a patient with a "PE unlikely" Wells score and negative age-adjusted D-dimer who had symptomatic venous thromboembolism during 3 months follow-up. A one-stage random effects meta-analysis was performed to estimate the efficiency and failure. The dataset comprised 938 patients with active cancer with a mean age of 63 years. The most frequent cancer types were breast (13%), gastrointestinal tract (11%), and lung (8%). The type of cancer was not specified in 42%. The pooled PE prevalence was 29% (95% CI 25-32). PE could be excluded in 122 patients based on a "PE unlikely" Wells score and a negative age-adjusted D-dimer (efficiency 13%; 95% CI 11-15). Two of 122 patients were diagnosed with non-fatal symptomatic venous thromboembolism during follow-up (failure rate 1.5%; 95% CI 0.13-14.8). The simplified Wells score in combination with a negative age-adjusted D-dimer had an efficiency of 3.9% (95% CI 2.0-7.6) and a failure rate of 2.4% (95% CI 0.3-15). Among cancer patients with clinically suspected PE, imaging and anticoagulant treatment can be withheld in 1 out of every 8 patients by the original Wells rule and age-adjusted D-dimer testing. The simplified Wells rule was neither efficient nor safe in this population. © 2016 Elsevier Ltd. All rights reserved.
Gajjar, Ketan; Ahmadzai, Abdullah A.; Valasoulis, George; Trevisan, Júlio; Founta, Christina; Nasioutziki, Maria; Loufopoulos, Aristotelis; Kyrgiou, Maria; Stasinou, Sofia Melina; Karakitsos, Petros; Paraskevaidis, Evangelos; Da Gama-Rose, Bianca; Martin-Hirsch, Pierre L.; Martin, Francis L.
2014-01-01
Background Subjective visual assessment of cervical cytology is flawed, and this can manifest itself by inter- and intra-observer variability resulting ultimately in the degree of discordance in the grading categorisation of samples in screening vs. representative histology. Biospectroscopy methods have been suggested as sensor-based tools that can deliver objective assessments of cytology. However, studies to date have been apparently flawed by a corresponding lack of diagnostic efficiency when samples have previously been classed using cytology screening. This raises the question as to whether categorisation of cervical cytology based on imperfect conventional screening reduces the diagnostic accuracy of biospectroscopy approaches; are these latter methods more accurate and diagnose underlying disease? The purpose of this study was to compare the objective accuracy of infrared (IR) spectroscopy of cervical cytology samples using conventional cytology vs. histology-based categorisation. Methods Within a typical clinical setting, a total of n = 322 liquid-based cytology samples were collected immediately before biopsy. Of these, it was possible to acquire subsequent histology for n = 154. Cytology samples were categorised according to conventional screening methods and subsequently interrogated employing attenuated total reflection Fourier-transform IR (ATR-FTIR) spectroscopy. IR spectra were pre-processed and analysed using linear discriminant analysis. Dunn’s test was applied to identify the differences in spectra. Within the diagnostic categories, histology allowed us to determine the comparative efficiency of conventional screening vs. biospectroscopy to correctly identify either true atypia or underlying disease. Results Conventional cytology-based screening results in poor sensitivity and specificity. IR spectra derived from cervical cytology do not appear to discriminate in a diagnostic fashion when categories were based on conventional screening. Scores plots of IR spectra exhibit marked crossover of spectral points between different cytological categories. Although, significant differences between spectral bands in different categories are noted, crossover samples point to the potential for poor specificity and hampers the development of biospectroscopy as a diagnostic tool. However, when histology-based categories are used to conduct analyses, the scores plot of IR spectra exhibit markedly better segregation. Conclusions Histology demonstrates that ATR-FTIR spectroscopy of liquid-based cytology identifies the presence of underlying atypia or disease missed in conventional cytology screening. This study points to an urgent need for a future biospectroscopy study where categories are based on such histology. It will allow for the validation of this approach as a screening tool. PMID:24404130
Wei, Kongyuan; Pan, Bei; Yang, Huan; Lu, Cuncun; Ge, Long; Cao, Nong
2018-04-01
Gastrointestinal stromal tumor (GIST) is a rare cancer in gastrointestinal carcinomas and has been widely known as a curable disease among all the digestive tumors. However, early detection of malignant potential in patients with GIST has still been a huge challenge all around the world. CT, MRI, and F-18 FDG PET are all considered as good tests for diagnosing malignant GIST efficiently, but no recommended suggestions presents which test among the 3 is the prior one in detecting the malignant potential of GIST. We perform this study to assess the accuracy between CT, MRI, and F-18 FDG PET through network meta-analysis method, and to rank these tests. PubMed, EMBASE.com, CNKI, and CBM databases will be searched without search date and language restrictions. We will include diagnostic tests which assessed the accuracy of CT, MRI, and F-18 FDG PET in detecting the malignant potential of GIST. The risk of bias in each study will be independently assessed as low, moderate, or high using criteria adapted from Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Meta-analysis will be performed using STATA 12.0 and R 3.4.1 software. The competing diagnostic tests will be ranked by a superiority index. This study is ongoing, and will be submitted to a peer-reviewed journal for publication. This study will provide a comprehensive evidence summary of CT, MRI, and F-18 FDG PET in detecting the malignant potential of GIST.
Computed tomography in the evaluation of penetrating neck trauma: a preliminary study.
Gracias, V H; Reilly, P M; Philpott, J; Klein, W P; Lee, S Y; Singer, M; Schwab, C W
2001-11-01
Penetrating neck trauma has traditionally been evaluated by surgical exploration and/or invasive diagnostic studies. We hypothesized that computed tomography (CT), used as an early diagnostic tool to accurately determine trajectory, would direct or eliminate further studies or procedures in stable patients with penetrating neck trauma. Retrospective case series. Academic, urban, level I trauma center. Hemodynamically stable patients without hard signs of vascular injury or aerodigestive violation who had sustained penetrating trauma to the neck. Patients underwent a spiral CT as an initial diagnostic study after initial evaluation in the trauma bay. Further invasive studies were directed by CT findings. Number of invasive studies performed. Twenty-three patients were identified during the 30-month period. Nineteen patients sustained gunshot wounds; 3, shotgun wounds; and 1, a stab wound. One patient died of a cranial gunshot wound. Three isolated zone I, 1 isolated zone II, 9 isolated zone III, and 10 multiple neck zone trajectories were evaluated. Thirteen patients were identified by CT to have trajectories remote from vital structures and required no further evaluation. Ten patients underwent angiography. Only 2 underwent bronchoscopy and esophagoscopy. Four patients were discharged from the emergency department; 7 other patients were discharged within 24 hours. No adverse patient events occurred before, during, or after CT scan. Computed tomography in stable selected patients with penetrating neck trauma appears safe. Invasive studies can often be eliminated from the diagnostic algorithm when CT demonstrates trajectories remote from vital structures. As a result, efficient evaluation and early discharge from the trauma bay or emergency department can be realized. Further prospective study of CT scan after penetrating neck trauma is needed.
Improving early cycle economic evaluation of diagnostic technologies.
Steuten, Lotte M G; Ramsey, Scott D
2014-08-01
The rapidly increasing range and expense of new diagnostics, compels consideration of a different, more proactive approach to health economic evaluation of diagnostic technologies. Early cycle economic evaluation is a decision analytic approach to evaluate technologies in development so as to increase the return on investment as well as patient and societal impact. This paper describes examples of 'early cycle economic evaluations' as applied to diagnostic technologies and highlights challenges in its real-time application. It shows that especially in the field of diagnostics, with rapid technological developments and a changing regulatory climate, early cycle economic evaluation can have a guiding role to improve the efficiency of the diagnostics innovation process. In the next five years the attention will move beyond the methodological and analytic challenges of early cycle economic evaluation towards the challenge of effectively applying it to improve diagnostic research and development and patient value. Future work in this area should therefore be 'strong on principles and soft on metrics', that is, the metrics that resonate most clearly with the various decision makers in this field.
OMOM capsule endoscopy in diagnosis of small bowel disease
Li, Chen-yi; Zhang, Bing-ling; Chen, Chun-xiao; Li, You-ming
2008-01-01
Objective: To assess the diagnostic efficiency of OMOM capsule endoscopy (CE) in a group of patients with different indications. Methods: Data from 89 consecutive patients (49 males, 40 females) with suspected small bowel disease who underwent OMOM CE (Jinshan Science and Technology Company, Chongqing, China) examination were obtained by retrospective review. The patients’ indications of the disease consisted of the following: obscure gastrointestinal bleeding (OGIB), abdominal pain or diarrhea, partial intestinal obstruction, suspected inflammatory bowel disease, tumor of unknown origin, hypoproteinemia, constipation, weight loss, and elevated tumor markers. Results: CE failed in one patient. Visualization of the entire small bowel was achieved in 75.0%. Capsules were naturally excreted by all patients. The detection rate of abnormalities was 70.5% for patients with suspected small bowel disease, and the diagnostic yield for patients with OGIB was higher than that for patients with abdominal pain or diarrhea (85.7% vs 53.3%, P<0.005). Angiodysplasia was the most common small bowel finding. Active bleeding sites were noted in the small intestine in 11 cases. Conclusion: OMOM CE is a useful diagnostic tool for the diagnosis of variably suspected small bowel disease, whose diagnostic efficiency is similar to that of the Pillcam SB (small bowel) CE (Given Imaging, Yoqneam, Israel). PMID:18988304
Franzen-Rohl, Elisabeth; Larsson, Kenny; Skoog, Eva; Tiveljung-Lindell, Annika; Grillner, Lena; Aurelius, Elisabeth; Glimåker, Martin
2008-01-01
Acute aseptic meningitis (AAM) affects 10-20/100,000 inhabitants per years in Sweden. Up to the beginning of the 1980s the diagnoses were made by virus isolation and/or determination of viral antibodies in serum. The development of PCR for detection of viruses in CSF samples has increased the sensitivity and diagnostic efficiency considerably. We investigated the aetiology of AAM and the diagnostic efficiency in an adult population in Stockholm, using a limited first-line combination of microbiological assays. CSF and serum samples, consecutively collected in 419 patients with clinical symptoms of AAM in northern Stockholm during 1999-2004, were included. PCR assays for herpes simplex virus (HSV) DNA and enterovirus (EV) RNA in the CSF as well as ELISA for IgM in serum to tick-borne encephalitis virus (TBEV) were performed routinely. A viral diagnosis was obtained in 255 of the 419 cases (62%) with these routinely performed assays. Clinical findings in combination with additional diagnostic tests resulted in an overall aetiological yield of 72%. EV was the major causative agent (27%) followed by TBEV (21%) and HSV-2 (19%). We conclude that consistent use of CSF-PCR for EV and HSV and TBEV serology established a diagnosis in the majority of AAM patients.
Assessment of Literature Related to Combustion Appliance Venting Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapp, V. H.; Less, B. D.; Singer, B. C.
In many residential building retrofit programs, air tightening to increase energy efficiency is often constrained by safety concerns with naturally vented combustion appliances. Tighter residential buildings more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spill combustion exhaust into the living space. Several measures, such as installation guidelines, vent sizing codes, and combustion safety diagnostics, are in place with the intent to prevent backdrafting and combustion spillage, but the diagnostics conflict and the risk mitigation objective is inconsistent. This literature review summarizes the metrics and diagnostics used to assess combustion safety, documents theirmore » technical basis, and investigates their risk mitigations. It compiles information from the following: codes for combustion appliance venting and installation; standards and guidelines for combustion safety diagnostics; research evaluating combustion safety diagnostics; research investigating wind effects on building depressurization and venting; and software for simulating vent system performance.« less
Efficient design and verification of diagnostics for impurity transport experiments.
Chilenski, M A; Greenwald, M J; Marzouk, Y M; Rice, J E; White, A E
2018-01-01
Recent attempts to measure impurity transport in Alcator C-Mod using an x-ray imaging crystal spectrometer and laser blow-off impurity injector have failed to yield unique reconstructions of the transport coefficient profiles. This paper presents a fast, linearized model which was constructed to estimate diagnostic requirements for impurity transport experiments. The analysis shows that the spectroscopic diagnostics on Alcator C-Mod should be capable of inferring simple profiles of impurity diffusion D Z and convection V Z accurate to better than ±10% uncertainty, suggesting that the failure to infer unique D Z and V Z from experimental data is attributable to an inadequate analysis procedure rather than the result of insufficient diagnostics. Furthermore, the analysis reveals that even a modest spatial resolution can overcome a low time resolution. This approach can be adapted to design and verify diagnostics for transport experiments on any magnetic confinement device.
Diagnosing Students' Understanding of the Nature of Models
NASA Astrophysics Data System (ADS)
Gogolin, Sarah; Krüger, Dirk
2017-10-01
Students' understanding of models in science has been subject to a number of investigations. The instruments the researchers used are suitable for educational research but, due to their complexity, cannot be employed directly by teachers. This article presents forced choice (FC) tasks, which, assembled as a diagnostic instrument, are supposed to measure students' understanding of the nature of models efficiently, while being sensitive enough to detect differences between individuals. In order to evaluate if the diagnostic instrument is suitable for its intended use, we propose an approach that complies with the demand to integrate students' responses to the tasks into the validation process. Evidence for validity was gathered based on relations to other variables and on students' response processes. Students' understanding of the nature of models was assessed using three methods: FC tasks, open-ended tasks and interviews ( N = 448). Furthermore, concurrent think-aloud protocols ( N = 30) were performed. The results suggest that the method and the age of the students have an effect on their understanding of the nature of models. A good understanding of the FC tasks as well as a convergence in the findings across the three methods was documented for grades eleven and twelve. This indicates that teachers can use the diagnostic instrument for an efficient and, at the same time, valid diagnosis for this group. Finally, the findings of this article may provide a possible explanation for alternative findings from previous studies as a result of specific methods that were used.
Schaefgen, Benedikt; Heil, Joerg; Barr, Richard G; Radicke, Marcus; Harcos, Aba; Gomez, Christina; Stieber, Anne; Hennigs, André; von Au, Alexandra; Spratte, Julia; Rauch, Geraldine; Rom, Joachim; Schütz, Florian; Sohn, Christof; Golatta, Michael
2018-06-01
To determine the feasibility of a prototype device combining 3D-automated breast ultrasound (ABVS) and digital breast tomosynthesis in a single device to detect and characterize breast lesions. In this prospective feasibility study, the FUSION-X-US prototype was used to perform digital breast tomosynthesis and ABVS in 23 patients with an indication for tomosynthesis based on current guidelines after clinical examination and standard imaging. The ABVS and tomosynthesis images of the prototype were interpreted separately by two blinded experts. The study compares the detection and BI-RADS® scores of breast lesions using only the tomosynthesis and ABVS data from the FUSION-X-US prototype to the results of the complete diagnostic workup. Image acquisition and processing by the prototype was fast and accurate, with some limitations in ultrasound coverage and image quality. In the diagnostic workup, 29 solid lesions (23 benign, including three cases with microcalcifications, and six malignant lesions) were identified. Using the prototype, all malignant lesions were detected and classified as malignant or suspicious by both investigators. Solid breast lesions can be localized accurately and fast by the Fusion-X-US system. Technical improvements of the ultrasound image quality and ultrasound coverage are needed to further study this new device. The prototype combines tomosynthesis and automated 3D-ultrasound (ABVS) in one device. It allows accurate detection of malignant lesions, directly correlating tomosynthesis and ABVS data. The diagnostic evaluation of the prototype-acquired data was interpreter-independent. The prototype provides a time-efficient and technically reliable diagnostic procedure. The combination of tomosynthesis and ABVS is a promising diagnostic approach.
NASA Astrophysics Data System (ADS)
Cohen, Luchino
Immune functions are altered during space flights. Latent virus reactivation, reduction in the number of immune cells, decreased cell activation and increased sensitivity of astronauts to infections following their return on Earth demonstrate that the immune system is less efficient during space flight. The causes of this immune deficiency are not fully understood and this dysfunction during long-term missions could result in the appearance of opportunistic infections or a decrease in the immuno-surveillance mechanisms that eradicate cancer cells. Therefore, the immune functions of astronauts will have to be monitored continuously during long-term missions in space, using miniature and semi-automated diagnostic systems. The objectives of this project are to study the causes of space-related immunodeficiency, to develop countermeasures to maintain an optimal immune function and to improve our capacity to detect infectious diseases during space missions through the monitoring of astronauts' immune system. In order to achieve these objectives, an Immune Function Diagnostic System (IFDS) will be designed to perform a set of immunological assays on board spacecrafts or on planet-bound bases. Through flow cytometric assays and molecular biology analyses, this diagnostic system could improve medical surveillance of astronauts and could be used to test countermeasures aimed at preventing immune deficiency during space missions. The capacity of the instrument to assess cellular fluorescence and to quantify the presence of soluble molecules in biological samples would support advanced molecular studies in space life sciences. Finally, such diagnostic system could also be used on Earth in remote areas or in mobile hospitals following natural disasters to fight against infectious diseases and other pathologies.
Li, Rui; Liu, Jianjun; Xue, Huiping; Huang, Gang
2012-10-15
The measurement of fecal tumor M2-pyruvate kinase (PKM2), overexpressed in tumor cells, has been proposed as a novel tool for detecting colorectal cancer (CRC). However, the sensitivity and specificity of this test varied among studies. The aim of this meta-analysis was to determine the diagnostic accuracy of fecal PKM2 for CRC and to evaluate its utility in the CRC screening. It was compared to guaiac fecal occult blood test (gFOBT) or immunological fecal occult blood test (iFOBT). Through comprehensive literature search, 10 studies met the inclusion criteria and were included. Summary estimates for sensitivity and specificity were calculated by using the bivariate random effect model. The hierarchical summary receiver operating characteristic curve was also undertaken. The overall sensitivity and specificity of fecal PKM2 for detecting CRC were 79% (95% CI = 75-83%) and 81% (95% CI = 73-87%), respectively. The summary positive predictive value and negative predictive value were 74% (95% CI = 56-87%) and 86% (95% CI = 79-91%), respectively. The pooled diagnostic odds ratio was 16 (95% CI = 10-26). In head-to-head comparison, the diagnostic odds ratio of PKM2 and gFOBT for CRC were 10.167 (95% CI = 5.992-17.250) and 6.557 (95% CI = 3.467-12.403), respectively. The diagnostic odds ratio of PKM2 and iFOBT for CRC were 9.542 (95% CI = 5.893-15.452) and 67.248 (95% CI = 16.194-279.26), respectively. The fecal PKM2 test was a diagnostic tool with moderate sensitivity and specificity for detecting CRC. Its diagnostic efficiency was similar to that of gFOBT. Because of its relatively low specificity and positive predict value, fecal PKM2 was not recommended used alone as a screening tool for CRC. Copyright © 2012 UICC.
Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael
2016-01-01
Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA stakeholders, clearer links between HTA and funding decisions, explicit recognition of and rationale for differential approaches to laboratory-developed versus regulatory-approved test, and clear evidence requirements. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1981-01-01
The research objectives of the NASA aircraft energy efficiency program are summarized. Engine component improvements for turbofan engines, diagnostics, the development of advanced turboprop engines, and propeller noise analysis are discussed.
Jang, Yu Jin; Chung, Hae Gyung; Choi, Jin Hee; Kim, Tae Yong; So, Hyung Seok
2016-01-01
Objective Post-traumatic stress disorder (PTSD) is often missed or incorrectly diagnosed in primary care settings. Although brief screening instruments may be useful in detecting PTSD, an adequate validation study has not been conducted with older adults. This study aimed to evaluate the reliability and validity of the Korean version of the primary care PTSD screen (PC-PTSD) and single-item PTSD screener (SIPS) in elderly veterans. Methods The PC-PTSD and SIPS assessments were translated into Korean, with a back-translation to the original language to verify accuracy. Vietnamese war veterans [separated into a PTSD group (n=41) and a non-PTSD group (n=99)] participated in several psychometric assessments, including the Korean versions of the PC-PTSD (PC-PTSD-K), SIPS (SIPS-K), a structured clinical interview from the Diagnostic and Statistical Manual of Mental Disorders-IV(SCID), and PTSD checklist(PCL). Results The PC-PTSD-K showed high internal consistency (Cronbach α=0.76), and the test-retest reliability of the PC-PTSD-K and SIPS-K were also high (r=0.97 and r=0.91, respectively). A total score of 3 from the PC-PTSD-K yielded the highest diagnostic efficiency, with sensitivity and specificity values of 0.90 and 0.86, respectively. The 'bothered a lot' response level from the SIPS-K showed the highest diagnostic efficiency, with sensitivity and specificity values of 0.85 and 0.89, respectively. Conclusion Our findings suggest that both PC-PTSD-K and SIPS-K have good psychometric properties with high validity and reliability for detecting PTSD symptoms in elderly Korean veterans. However, further research will be necessary to increase our understanding of PTSD characteristics in diverse groups with different types of trauma. PMID:27482241
Aircraft Energy Efficiency (ACEE) status report
NASA Technical Reports Server (NTRS)
Nored, D. L.; Dugan, J. F., Jr.; Saunders, N. T.; Ziemianski, J. A.
1979-01-01
Fuel efficiency in aeronautics, for fuel conservation in general as well as for its effect on commercial aircraft operating economics is considered. Projects of the Aircraft Energy Efficiency Program related to propulsion are emphasized. These include: (1) engine component improvement, directed at performance improvement and engine diagnostics for prolonged service life; (2) energy efficient engine, directed at proving the technology base for the next generation of turbofan engines; and (3) advanced turboprop, directed at advancing the technology of turboprop powered aircraft to a point suitable for commercial airline service. Progress in these technology areas is reported.
ERIC Educational Resources Information Center
Rutherford, Marion; Burns, Morag; Gray, Duncan; Bremner, Lynne; Clegg, Sarah; Russell, Lucy; Smith, Charlie; O'Hare, Anne
2018-01-01
The 'autism diagnosis crisis' and long waiting times for assessment are as yet unresolved, leading to undue stress and limiting access to effective support. There is therefore a significant need for evidence to support practitioners in the development of efficient services, delivering acceptable waiting times and effectively meeting guideline…
Efficiency and Effectiveness of Drama Techniques in the English Classroom
ERIC Educational Resources Information Center
Lizasoain, Andrea; Ortiz de Zarate, Amalia
2009-01-01
According to the national results of the English diagnostic test (2004) applied to Chilean 8th and 12th graders, the current English teaching methodology used in this country is not efficient nor effective. Consequently, a different methodology is urgently needed, particularly in a context where students primarily come from rural areas and will be…
Nixon, Gavin J; Svenstrup, Helle F; Donald, Carol E; Carder, Caroline; Stephenson, Judith M; Morris-Jones, Stephen; Huggett, Jim F; Foy, Carole A
2014-12-01
Molecular diagnostic measurements are currently underpinned by the polymerase chain reaction (PCR). There are also a number of alternative nucleic acid amplification technologies, which unlike PCR, work at a single temperature. These 'isothermal' methods, reportedly offer potential advantages over PCR such as simplicity, speed and resistance to inhibitors and could also be used for quantitative molecular analysis. However there are currently limited mechanisms to evaluate their quantitative performance, which would assist assay development and study comparisons. This study uses a sexually transmitted infection diagnostic model in combination with an adapted metric termed isothermal doubling time (IDT), akin to PCR efficiency, to compare quantitative PCR and quantitative loop-mediated isothermal amplification (qLAMP) assays, and to quantify the impact of matrix interference. The performance metric described here facilitates the comparison of qLAMP assays that could assist assay development and validation activities.
A hybrid framework for quantifying the influence of data in hydrological model calibration
NASA Astrophysics Data System (ADS)
Wright, David P.; Thyer, Mark; Westra, Seth; McInerney, David
2018-06-01
Influence diagnostics aim to identify a small number of influential data points that have a disproportionate impact on the model parameters and/or predictions. The key issues with current influence diagnostic techniques are that the regression-theory approaches do not provide hydrologically relevant influence metrics, while the case-deletion approaches are computationally expensive to calculate. The main objective of this study is to introduce a new two-stage hybrid framework that overcomes these challenges, by delivering hydrologically relevant influence metrics in a computationally efficient manner. Stage one uses computationally efficient regression-theory influence diagnostics to identify the most influential points based on Cook's distance. Stage two then uses case-deletion influence diagnostics to quantify the influence of points using hydrologically relevant metrics. To illustrate the application of the hybrid framework, we conducted three experiments on 11 hydro-climatologically diverse Australian catchments using the GR4J hydrological model. The first experiment investigated how many data points from stage one need to be retained in order to reliably identify those points that have the hightest influence on hydrologically relevant metrics. We found that a choice of 30-50 is suitable for hydrological applications similar to those explored in this study (30 points identified the most influential data 98% of the time and reduced the required recalibrations by 99% for a 10 year calibration period). The second experiment found little evidence of a change in the magnitude of influence with increasing calibration period length from 1, 2, 5 to 10 years. Even for 10 years the impact of influential points can still be high (>30% influence on maximum predicted flows). The third experiment compared the standard least squares (SLS) objective function with the weighted least squares (WLS) objective function on a 10 year calibration period. In two out of three flow metrics there was evidence that SLS, with the assumption of homoscedastic residual error, identified data points with higher influence (largest changes of 40%, 10%, and 44% for the maximum, mean, and low flows, respectively) than WLS, with the assumption of heteroscedastic residual errors (largest changes of 26%, 6%, and 6% for the maximum, mean, and low flows, respectively). The hybrid framework complements existing model diagnostic tools and can be applied to a wide range of hydrological modelling scenarios.
NASA Technical Reports Server (NTRS)
Jong, Jen-Yi
1996-01-01
NASA's advanced propulsion system Small Scale Magnetic Disturbances/Advanced Technology Development (SSME/ATD) has been undergoing extensive flight certification and developmental testing, which involves large numbers of health monitoring measurements. To enhance engine safety and reliability, detailed analysis and evaluation of the measurement signals are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce the risk of catastrophic system failures and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. During the development of SSME, ASRI participated in the research and development of several advanced non- linear signal diagnostic methods for health monitoring and failure prediction in turbomachinery components. However, due to the intensive computational requirement associated with such advanced analysis tasks, current SSME dynamic data analysis and diagnostic evaluation is performed off-line following flight or ground test with a typical diagnostic turnaround time of one to two days. The objective of MSFC's MPP Prototype System is to eliminate such 'diagnostic lag time' by achieving signal processing and analysis in real-time. Such an on-line diagnostic system can provide sufficient lead time to initiate corrective action and also to enable efficient scheduling of inspection, maintenance and repair activities. The major objective of this project was to convert and implement a number of advanced nonlinear diagnostic DSP algorithms in a format consistent with that required for integration into the Vanderbilt Multigraph Architecture (MGA) Model Based Programming environment. This effort will allow the real-time execution of these algorithms using the MSFC MPP Prototype System. ASRI has completed the software conversion and integration of a sequence of nonlinear signal analysis techniques specified in the SOW for real-time execution on MSFC's MPP Prototype. This report documents and summarizes the results of the contract tasks; provides the complete computer source code; including all FORTRAN/C Utilities; and all other utilities/supporting software libraries that are required for operation.
Reexamining our bias against heuristics.
McLaughlin, Kevin; Eva, Kevin W; Norman, Geoff R
2014-08-01
Using heuristics offers several cognitive advantages, such as increased speed and reduced effort when making decisions, in addition to allowing us to make decision in situations where missing data do not allow for formal reasoning. But the traditional view of heuristics is that they trade accuracy for efficiency. Here the authors discuss sources of bias in the literature implicating the use of heuristics in diagnostic error and highlight the fact that there are also data suggesting that under certain circumstances using heuristics may lead to better decisions that formal analysis. They suggest that diagnostic error is frequently misattributed to the use of heuristics and propose an alternative view whereby content knowledge is the root cause of diagnostic performance and heuristics lie on the causal pathway between knowledge and diagnostic error or success.
Transcriptome Profiling of Antimicrobial Resistance in Pseudomonas aeruginosa.
Khaledi, Ariane; Schniederjans, Monika; Pohl, Sarah; Rainer, Roman; Bodenhofer, Ulrich; Xia, Boyang; Klawonn, Frank; Bruchmann, Sebastian; Preusse, Matthias; Eckweiler, Denitsa; Dötsch, Andreas; Häussler, Susanne
2016-08-01
Emerging resistance to antimicrobials and the lack of new antibiotic drug candidates underscore the need for optimization of current diagnostics and therapies to diminish the evolution and spread of multidrug resistance. As the antibiotic resistance status of a bacterial pathogen is defined by its genome, resistance profiling by applying next-generation sequencing (NGS) technologies may in the future accomplish pathogen identification, prompt initiation of targeted individualized treatment, and the implementation of optimized infection control measures. In this study, qualitative RNA sequencing was used to identify key genetic determinants of antibiotic resistance in 135 clinical Pseudomonas aeruginosa isolates from diverse geographic and infection site origins. By applying transcriptome-wide association studies, adaptive variations associated with resistance to the antibiotic classes fluoroquinolones, aminoglycosides, and β-lactams were identified. Besides potential novel biomarkers with a direct correlation to resistance, global patterns of phenotype-associated gene expression and sequence variations were identified by predictive machine learning approaches. Our research serves to establish genotype-based molecular diagnostic tools for the identification of the current resistance profiles of bacterial pathogens and paves the way for faster diagnostics for more efficient, targeted treatment strategies to also mitigate the future potential for resistance evolution. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Transcriptome Profiling of Antimicrobial Resistance in Pseudomonas aeruginosa
Khaledi, Ariane; Schniederjans, Monika; Pohl, Sarah; Rainer, Roman; Bodenhofer, Ulrich; Xia, Boyang; Klawonn, Frank; Bruchmann, Sebastian; Preusse, Matthias; Eckweiler, Denitsa; Dötsch, Andreas
2016-01-01
Emerging resistance to antimicrobials and the lack of new antibiotic drug candidates underscore the need for optimization of current diagnostics and therapies to diminish the evolution and spread of multidrug resistance. As the antibiotic resistance status of a bacterial pathogen is defined by its genome, resistance profiling by applying next-generation sequencing (NGS) technologies may in the future accomplish pathogen identification, prompt initiation of targeted individualized treatment, and the implementation of optimized infection control measures. In this study, qualitative RNA sequencing was used to identify key genetic determinants of antibiotic resistance in 135 clinical Pseudomonas aeruginosa isolates from diverse geographic and infection site origins. By applying transcriptome-wide association studies, adaptive variations associated with resistance to the antibiotic classes fluoroquinolones, aminoglycosides, and β-lactams were identified. Besides potential novel biomarkers with a direct correlation to resistance, global patterns of phenotype-associated gene expression and sequence variations were identified by predictive machine learning approaches. Our research serves to establish genotype-based molecular diagnostic tools for the identification of the current resistance profiles of bacterial pathogens and paves the way for faster diagnostics for more efficient, targeted treatment strategies to also mitigate the future potential for resistance evolution. PMID:27216077
[Intestinal parasitic diseases in children].
Mare, Anca; Man, A; Toma, Felicia; Székely, Edit; Lôrinczi, Lilla; Sipoş, Anca
2007-01-01
To compare the incidence of intestinal parasitosis between children with residence in urban and rural areas: to compare the efficacy of parasitologic diagnostic methods. In our study we included two lots of children. The first lot consisted in 74 children from rural areas from which we collected 44 samples of feces and 55 samples for the "Scotch tape" test. The second lot consisted in 214 children from urban areas from which we collected 44 samples of feces. We examined each sample of feces by three different methods. The study was performed between April to June 2006. The incidence of intestinal parasitosis increases in children from urban areas towards rural areas, and in children between 5 and 10 years. Ascariasis is the most frequent disease in both urban and rural areas. By examination of each fecal sample by three different methods, the number of positive cases increased. The residence in rural areas and age between 5 to 10 years are risk factors for intestinal parasitosis. The "Scotch tape" test was more efficient in Enterobius vermicularis infection than the methods performed from feces. We recommend using at the same time three diagnostic methods for feces examination to improve the diagnostic sensibility.
Tan, Xiao Wei; Zheng, Qishi; Shi, Luming; Gao, Fei; Allen, John Carson; Coenen, Adriaan; Baumann, Stefan; Schoepf, U Joseph; Kassab, Ghassan S; Lim, Soo Teik; Wong, Aaron Sung Lung; Tan, Jack Wei Chieh; Yeo, Khung Keong; Chin, Chee Tang; Ho, Kay Woon; Tan, Swee Yaw; Chua, Terrance Siang Jin; Chan, Edwin Shih Yen; Tan, Ru San; Zhong, Liang
2017-06-01
To evaluate the combined diagnostic accuracy of coronary computed tomography angiography (CCTA) and computed tomography derived fractional flow reserve (FFRct) in patients with suspected or known coronary artery disease (CAD). PubMed, The Cochrane library, Embase and OpenGray were searched to identify studies comparing diagnostic accuracy of CCTA and FFRct. Diagnostic test measurements of FFRct were either extracted directly from the published papers or calculated from provided information. Bivariate models were conducted to synthesize the diagnostic performance of combined CCTA and FFRct at both "per-vessel" and "per-patient" levels. 7 articles were included for analysis. The combined diagnostic outcomes from "both positive" strategy, i.e. a subject was considered as "positive" only when both CCTA and FFRct were "positive", demonstrated relative high specificity (per-vessel: 0.91; per-patient: 0.81), high positive likelihood ratio (LR+, per-vessel: 7.93; per-patient: 4.26), high negative likelihood ratio (LR-, per-vessel: 0.30; per patient: 0.24) and high accuracy (per-vessel: 0.91; per-patient: 0.81) while "either positive" strategy, i.e. a subject was considered as "positive" when either CCTA or FFRct was "positive", demonstrated relative high sensitivity (per-vessel: 0.97; per-patient: 0.98), low LR+ (per-vessel: 1.50; per-patient: 1.17), low LR- (per-vessel: 0.07; per-patient: 0.09) and low accuracy (per-vessel: 0.57; per-patient: 0.54). "Both positive" strategy showed better diagnostic performance to rule in patients with non-significant stenosis compared to "either positive" strategy, as it efficiently reduces the proportion of testing false positive subjects. Copyright © 2017 Elsevier B.V. All rights reserved.
Fukuda, Haruhisa; Ikeda, Shunya; Shiroiwa, Takeru; Fukuda, Takashi
2016-10-01
Inaccurate estimates of diabetes-related healthcare costs can undermine the efficiency of resource allocation for diabetes care. The quantification of these costs using claims data may be affected by the method for defining diagnoses. The aims were to use panel data analysis to estimate diabetes-related healthcare costs and to comparatively evaluate the effects of diagnostic definitions on cost estimates. Monthly panel data analysis of Japanese claims data. The study included a maximum of 141,673 patients with type 2 diabetes who received treatment between 2005 and 2013. Additional healthcare costs associated with diabetes and diabetes-related complications were estimated for various diagnostic definition methods using fixed-effects panel data regression models. The average follow-up period per patient ranged from 49.4 to 52.3 months. The number of patients identified as having type 2 diabetes varied widely among the diagnostic definition methods, ranging from 14,743 patients to 141,673 patients. The fixed-effects models showed that the additional costs per patient per month associated with diabetes ranged from US$180 [95 % confidence interval (CI) 178-181] to US$223 (95 % CI 221-224). When the diagnostic definition excluded rule-out diagnoses, the diabetes-related complications associated with higher additional healthcare costs were ischemic heart disease with surgery (US$13,595; 95 % CI 13,568-13,622), neuropathy/extremity disease with surgery (US$4594; 95 % CI 3979-5208), and diabetic nephropathy with dialysis (US$3689; 95 % CI 3667-3711). Diabetes-related healthcare costs are sensitive to diagnostic definition methods. Determining appropriate diagnostic definitions can further advance healthcare cost research for diabetes and its applications in healthcare policies.
Harrison, Sheri D; Harrison, Mark A; Duvall, W Lane
2012-05-01
Emergency room evaluations of patients presenting with chest pain continue to rise, and these evaluations which often include cardiac imaging, are an increasing area of resource utilization in the current health system. Myocardial perfusion imaging from the emergency department remains a vital component of the diagnosis or exclusion of coronary artery disease as the etiology of chest pain. Recent advances in camera technology, and changes to the imaging protocols have allowed MPI to become a more efficient way of providing this diagnostic information. Compared with conventional SPECT, new high-efficiency CZT cameras provide a 3-5 fold increase in photon sensitivity, 1.65-fold improvement in energy resolution and a 1.7-2.5-fold increase in spatial resolution. With stress-only imaging, rest images are eliminated if stress images are normal, as they provide no additional prognostic or diagnostic value and cancelling the rest images would shorten the length of the test which is of particular importance to the ED population. The rapid but accurate triage of patients in an ED CPU is essential to their care, and stress-only imaging and new CZT cameras allow for shorter test time, lower radiation doses and lower costs while demonstrating good clinical outcomes. These changes to nuclear stress testing can allow for faster throughput of patients through the emergency department while providing a safe and efficient evaluation of chest pain.
Far-Field Plume Measurements of a Nested-Channel Hall-Effect Thruster (PREPRINT)
2010-12-13
nude Faraday probe, retarding potential analyzer, and ExB probe. Data from these probes were used to calculate utilization efficiencies from existing...USA Far-field plume measurements were performed on the X2 nested-channel Hall-effect thruster using an ar- ray of diagnostics, including a nude Faraday...mode to nested-channel mode by utilizing a traditional array of far-field diagnostics, which include a nude Faraday probe, retarding potential analyzer
Measure Guideline: Air Conditioner Diagnostics, Maintenance, and Replacement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Springer, D.; Dakin, B.
2013-03-01
This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.
Measure Guideline. Air Conditioner Diagnostics, Maintenance, and Replacement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Springer, David; Dakin, Bill
2013-03-01
This guideline responds to the need for an efficient means of identifying, diagnosing, and repairing faults in air conditioning systems in existing homes that are undergoing energy upgrades. Inadequate airflow due to constricted ducts or undersized filters, improper refrigerant charge, and other system defects can be corrected at a fraction of the cost of equipment replacement and can yield significant savings. The guideline presents a two-step approach to diagnostics and repair.
energy efficiency technologies and managing the commercial building energy assessment trainings that NREL detection and diagnostics for commercial buildings Commercial building energy audits and photovoltaic system
An Energy Efficient ECG Signal Processor Detecting Cardiovascular Diseases on Smartphone.
Jain, Sanjeev Kumar; Bhaumik, Basabi
2017-04-01
A novel disease diagnostic algorithm for ECG signal processing based on forward search is implemented in Application Specific Integrated Circuit (ASIC) for cardiovascular disease diagnosis on smartphone. An ASIC is fabricated using 130-nm CMOS low leakage process technology. The area of our PQRST ASIC is 1.21 mm 2 . The energy dissipation of PQRST ASIC is 96 pJ with a supply voltage of 0.9 V. The outputs from the ASIC are fed to an Android application that generates diagnostic report and can be sent to a cardiologist via email. The ASIC and Android application are verified for the detection of bundle branch block, hypertrophy, arrhythmia and myocardial infarction using Physionet PTB diagnostic ECG database. The failed detection rate is 0.69%, 0.69%, 0.34% and 1.72% for bundle branch block, hypertrophy, arrhythmia and myocardial infarction respectively. The AV block is detected in all the three patients in the Physionet St. Petersburg arrhythmia database. Our proposed ASIC together with our Android application is the most suitable for an energy efficient wearable cardiovascular disease detection system.
Yang, Huaan; Jian, Jianbo; Li, Xuan; Renshaw, Daniel; Clements, Jonathan; Sweetingham, Mark W; Tan, Cong; Li, Chengdao
2015-09-02
Molecular marker-assisted breeding provides an efficient tool to develop improved crop varieties. A major challenge for the broad application of markers in marker-assisted selection is that the marker phenotypes must match plant phenotypes in a wide range of breeding germplasm. In this study, we used the legume crop species Lupinus angustifolius (lupin) to demonstrate the utility of whole genome sequencing and re-sequencing on the development of diagnostic markers for molecular plant breeding. Nine lupin cultivars released in Australia from 1973 to 2007 were subjected to whole genome re-sequencing. The re-sequencing data together with the reference genome sequence data were used in marker development, which revealed 180,596 to 795,735 SNP markers from pairwise comparisons among the cultivars. A total of 207,887 markers were anchored on the lupin genetic linkage map. Marker mining obtained an average of 387 SNP markers and 87 InDel markers for each of the 24 genome sequence assembly scaffolds bearing markers linked to 11 genes of agronomic interest. Using the R gene PhtjR conferring resistance to phomopsis stem blight disease as a test case, we discovered 17 candidate diagnostic markers by genotyping and selecting markers on a genetic linkage map. A further 243 candidate diagnostic markers were discovered by marker mining on a scaffold bearing non-diagnostic markers linked to the PhtjR gene. Nine out from the ten tested candidate diagnostic markers were confirmed as truly diagnostic on a broad range of commercial cultivars. Markers developed using these strategies meet the requirements for broad application in molecular plant breeding. We demonstrated that low-cost genome sequencing and re-sequencing data were sufficient and very effective in the development of diagnostic markers for marker-assisted selection. The strategies used in this study may be applied to any trait or plant species. Whole genome sequencing and re-sequencing provides a powerful tool to overcome current limitations in molecular plant breeding, which will enable plant breeders to precisely pyramid favourable genes to develop super crop varieties to meet future food demands.
NASA Technical Reports Server (NTRS)
Mcgary, M. C.
1986-01-01
The anticipated application of advanced turboprop propulsion systems and use of composite materials in primary structure is expected to increase the interior noise of future aircraft to unacceptability high levels. The absence of technically and economically feasible noise source-path diagnostic tools has been a primer obstacle in the development of efficient noise control treatments for propeller driven aircraft. A new diagnostic method which permits the separation and prediction of the fully coherent airborne and structureborne components of the sound radiated by plates or thin shells has been developed. Analytical and experimental studies of the proposed method were performed on plates constructed of both conventional and composite materials. The results of the study indicate that the proposed method can be applied to a variety of aircraft materials, could be used in flight, and has fewer encumbrances than the other diagnostic tools currently available. The study has also revealed that the noise radiation of vibrating plates in the low frequency regime due to combined airborne and structureborne inputs possesses a strong synergistic nature. The large influence of the interaction between the airborne and structureborne terms has been hitherto ignored by researchers of aircraft interior noise problems.
Demaison, X; Rapp, C; de Laval, F; Simon, F
2013-04-01
Non-falciparum malaria is less studied than Plasmodium falciparum malaria, both in endemic and non-endemic zones. A retrospective study was made of the medical files of patients managed for attacks of malaria due to Plasmodium vivax or Plasmodium ovale, between 2000 and 2009, in two French military teaching hospitals. Seventy-five percent of attacks occurred after a stay in French Guiana, in the Comoros Archipelago, or in the Ivory Coast Republic. The most frequent symptoms two months after coming back were a flu-like syndrome with headaches, and occasional digestive symptoms, without any difference between the first attack and recurrence. One third of patients presented with anemia, 78% with thrombocytopenia, and 12% with liver dysfunction. This study was the most important made in France on imported non-falciparum malaria. Military patients and immigrants accounted for a majority of patients due to the specificity of military hospitals and local recruitment. Clinical and biological features were not specific and did not allow guiding the diagnosis. Diagnostic tools were less sensitive for P. ovale. Patient management could be optimized by more efficient diagnostic tools, specific guidelines for the diagnostic and therapeutic management, and a dedicated medical training for family practitioners as well as hospitals practice. Copyright © 2013. Published by Elsevier SAS.
The modern trends of the evolution laser information technology in oncology
NASA Astrophysics Data System (ADS)
Mikov, A. A.; Svirin, V. N.
2008-04-01
Laser-optical information technologies and devices develop since the 70- years at the end of 20 century and are broadly used for diagnostics and treatment of oncological diseases to date. Although such methods as photodynamic therapy (PDT), laser-induce thermotherapy (LITT), fluorescent diagnostics and spectrophotometry already more than 30 years are used for treatment and diagnostics of oncological diseases, nevertheless, they are enough new methods and, as a rule, are used in large scientific centers and medical institutions. This is bound, first of all, with lack of information on modern method of cancer treatment, the absence of widely available laser procedures and corresponding devices in the polyclinics and even in district hospitals, as well as insufficient understanding of application areas, where laser methods has an advantage by comparison, for instance, with beam or chemotherapy. At present day laser methods are fast upcoming direction of the treatment oncological diseases. This is explained by progress in development essentially laser, particularly diode, improvement electronic and computing components and broad introduction software-algorithmic methods of control the undertaking therapeutic and diagnostic procedures. In article are considered new laser methods of the undertaking diagnostic and therapeutic procedures and is shown that introduction multiwave laser radiation for probe and influences on tissue, the different methods of the determination of the functional state of tissues, realization of the on-line diagnostics when carrying out the therapeutic procedures, automatic control systems of the power laser radiation, which depends on state patient tissue, as well as software-algorithmic methods of management session therapeutic and diagnostic procedures greatly raises efficiency of the treatment oncological diseases. On an example of the multipurpose laser therapeutic devices("MLTA") developed and introduced in clinical practice and multipurpose laser diagnostic complexes ("MLDC"), the realizing offered methods, are shown the basic tendencies of development laser methods in oncology, concrete technical decisions and the experimental clinical material showing increase of efficiency of treatment of a cancer at their realization are resulted. It is shown, that realization of the offered methods and technical technologies opens new competitive advantages laser technologies in comparison with beam and chemical-therapy at treatment of oncological diseases.
NASA Technical Reports Server (NTRS)
Myers, L. P.; Burcham, F. W., Jr.
1983-01-01
Substantial benefits of a full authority digital electronic engine control on an air breathing engine were demonstrated repeatedly in simulation studies, ground engine tests, and engine altitude test facilities. A digital engine electronic control system showed improvements in efficiency, performance, and operation. An additional benefit of full authority digital controls is the capability of detecting and correcting failures and providing engine health diagnostics.
Electric machine differential for vehicle traction control and stability control
NASA Astrophysics Data System (ADS)
Kuruppu, Sandun Shivantha
Evolving requirements in energy efficiency and tightening regulations for reliable electric drivetrains drive the advancement of the hybrid electric (HEV) and full electric vehicle (EV) technology. Different configurations of EV and HEV architectures are evaluated for their performance. The future technology is trending towards utilizing distinctive properties in electric machines to not only to improve efficiency but also to realize advanced road adhesion controls and vehicle stability controls. Electric machine differential (EMD) is such a concept under current investigation for applications in the near future. Reliability of a power train is critical. Therefore, sophisticated fault detection schemes are essential in guaranteeing reliable operation of a complex system such as an EMD. The research presented here emphasize on implementation of a 4kW electric machine differential, a novel single open phase fault diagnostic scheme, an implementation of a real time slip optimization algorithm and an electric machine differential based yaw stability improvement study. The proposed d-q current signature based SPO fault diagnostic algorithm detects the fault within one electrical cycle. The EMD based extremum seeking slip optimization algorithm reduces stopping distance by 30% compared to hydraulic braking based ABS.
Theranostic potential of gold nanoparticle-protein agglomerates
NASA Astrophysics Data System (ADS)
Sanpui, Pallab; Paul, Anumita; Chattopadhyay, Arun
2015-11-01
Owing to the ever-increasing applications, glittered with astonishing success of gold nanoparticles (Au NPs) in biomedical research as diagnostic and therapeutic agents, the study of Au NP-protein interaction seems critical for maximizing their theranostic efficiency, and thus demands comprehensive understanding. The mutual interaction of Au NPs and proteins at physiological conditions may result in the aggregation of protein, which can ultimately lead to the formation of Au NP-protein agglomerates. In the present article, we try to appreciate the plausible steps involved in the Au NP-induced aggregation of proteins and also the importance of the proteins' three-dimensional structures in the process. The Au NP-protein agglomerates can potentially be exploited for efficient loading and subsequent release of various therapeutically important molecules, including anticancer drugs, with the unique opportunity of incorporating hydrophilic as well as hydrophobic drugs in the same nanocarrier system. Moreover, the Au NP-protein agglomerates can act as `self-diagnostic' systems, allowing investigation of the conformational state of the associated protein(s) as well as the protein-protein or protein-Au NP interaction within the agglomerates. Furthermore, the potential of these Au NP-protein agglomerates as a novel platform for multifunctional theranostic application along with exciting future-possibilities is highlighted here.
Perinetti, Giuseppe; Contardo, Luca
2017-01-01
Current evidence on the reliability of growth indicators in the identification of the pubertal growth spurt and efficiency of functional treatment for skeletal Class II malocclusion, the timing of which relies on such indicators, is highly controversial. Regarding growth indicators, the hand and wrist (including the sole middle phalanx of the third finger) maturation method and the standing height recording appear to be most reliable. Other methods are subjected to controversies or were showed to be unreliable. Main sources of controversies include use of single stages instead of ossification events and diagnostic reliability conjecturally based on correlation analyses. Regarding evidence on the efficiency of functional treatment, when treated during the pubertal growth spurt, more favorable response is seen in skeletal Class II patients even though large individual responsiveness remains. Main sources of controversies include design of clinical trials, definition of Class II malocclusion, and lack of inclusion of skeletal maturity among the prognostic factors. While no growth indicator may be considered to have a full diagnostic reliability in the identification of the pubertal growth spurt, their use may still be recommended for increasing efficiency of functional treatment for skeletal Class II malocclusion.
2017-01-01
Current evidence on the reliability of growth indicators in the identification of the pubertal growth spurt and efficiency of functional treatment for skeletal Class II malocclusion, the timing of which relies on such indicators, is highly controversial. Regarding growth indicators, the hand and wrist (including the sole middle phalanx of the third finger) maturation method and the standing height recording appear to be most reliable. Other methods are subjected to controversies or were showed to be unreliable. Main sources of controversies include use of single stages instead of ossification events and diagnostic reliability conjecturally based on correlation analyses. Regarding evidence on the efficiency of functional treatment, when treated during the pubertal growth spurt, more favorable response is seen in skeletal Class II patients even though large individual responsiveness remains. Main sources of controversies include design of clinical trials, definition of Class II malocclusion, and lack of inclusion of skeletal maturity among the prognostic factors. While no growth indicator may be considered to have a full diagnostic reliability in the identification of the pubertal growth spurt, their use may still be recommended for increasing efficiency of functional treatment for skeletal Class II malocclusion. PMID:28168195
Fleischman, Rafael; Amiel, Ran; Czerwinski, Jan; Mayer, Andreas; Tartakovsky, Leonid
2018-05-01
Retrofitting older vehicles with diesel particulate filter (DPF) is a cost-effective measure to quickly and efficiently reduce particulate matter emissions. This study experimentally analyzes real-world performance of buses retrofitted with CRT DPFs. 18 in-use Euro III technology urban and intercity buses were investigated for a period of 12months. The influence of the DPF and of the vehicle natural aging on buses fuel economy are analyzed and discussed. While the effect of natural deterioration is about 1.2%-1.3%, DPF contribution to fuel economy penalty is found to be 0.6% to 1.8%, depending on the bus type. DPF filtration efficiency is analyzed throughout the study and found to be in average 96% in the size range of 23-560nm. Four different load and non-load engine operating modes are investigated on their appropriateness for roadworthiness tests. High idle is found to be the most suitable regime for PN diagnostics considering particle number filtration efficiency. Copyright © 2017. Published by Elsevier B.V.
Enabling smart personalized healthcare: a hybrid mobile-cloud approach for ECG telemonitoring.
Wang, Xiaoliang; Gui, Qiong; Liu, Bingwei; Jin, Zhanpeng; Chen, Yu
2014-05-01
The severe challenges of the skyrocketing healthcare expenditure and the fast aging population highlight the needs for innovative solutions supporting more accurate, affordable, flexible, and personalized medical diagnosis and treatment. Recent advances of mobile technologies have made mobile devices a promising tool to manage patients' own health status through services like telemedicine. However, the inherent limitations of mobile devices make them less effective in computation- or data-intensive tasks such as medical monitoring. In this study, we propose a new hybrid mobile-cloud computational solution to enable more effective personalized medical monitoring. To demonstrate the efficacy and efficiency of the proposed approach, we present a case study of mobile-cloud based electrocardiograph monitoring and analysis and develop a mobile-cloud prototype. The experimental results show that the proposed approach can significantly enhance the conventional mobile-based medical monitoring in terms of diagnostic accuracy, execution efficiency, and energy efficiency, and holds the potential in addressing future large-scale data analysis in personalized healthcare.
MO-F-204-04: Preparing for Parts 2 & 3 of the ABR Nuclear Medicine Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDougall, R.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of allmore » aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
WE-D-213-04: Preparing for Parts 2 & 3 of the ABR Nuclear Medicine Physics Exam
DOE Office of Scientific and Technical Information (OSTI.GOV)
MacDougall, R.
Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance ofmore » all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.« less
Diagnostic grade wireless ECG monitoring.
Garudadri, Harinath; Chi, Yuejie; Baker, Steve; Majumdar, Somdeb; Baheti, Pawan K; Ballard, Dan
2011-01-01
In remote monitoring of Electrocardiogram (ECG), it is very important to ensure that the diagnostic integrity of signals is not compromised by sensing artifacts and channel errors. It is also important for the sensors to be extremely power efficient to enable wearable form factors and long battery life. We present an application of Compressive Sensing (CS) as an error mitigation scheme at the application layer for wearable, wireless sensors in diagnostic grade remote monitoring of ECG. In our previous work, we described an approach to mitigate errors due to packet losses by projecting ECG data to a random space and recovering a faithful representation using sparse reconstruction methods. Our contributions in this work are twofold. First, we present an efficient hardware implementation of random projection at the sensor. Second, we validate the diagnostic integrity of the reconstructed ECG after packet loss mitigation. We validate our approach on MIT and AHA databases comprising more than 250,000 normal and abnormal beats using EC57 protocols adopted by the Food and Drug Administration (FDA). We show that sensitivity and positive predictivity of a state-of-the-art ECG arrhythmia classifier is essentially invariant under CS based packet loss mitigation for both normal and abnormal beats even at high packet loss rates. In contrast, the performance degrades significantly in the absence of any error mitigation scheme, particularly for abnormal beats such as Ventricular Ectopic Beats (VEB).
Forceps biopsy and suction catheter for sampling in pulmonary nodules and infiltrates.
Peschke, Antje; Wiedemann, Bärbel; Höffken, Gert; Koschel, Dirk
2012-06-01
Transbronchial lung biopsy with forceps is a standard procedure in bronchoscopic tissue sampling. Suction catheter aspiration is another technique, but it is not widely known and almost no data exist regarding its diagnostic efficiency. 272 patients were included in a prospective and randomised study between February 2007 and October 2009. All were referred for bronchoscopic evaluation of pulmonary nodules/masses or infiltrates. We compared the diagnostic yield of forceps biopsy and suction catheter aspiration for a definite diagnosis and looked at whether such a diagnosis depends on the underlying pulmonary change. All patients underwent bronchoscopy with forceps biopsy and catheter aspiration. A definitive diagnosis was reached in a total of 183 (67.3%) patients, with catheter aspiration in 140 (51.5%) patients and with forceps biopsy in 136 (50.0%) patients. In 90 (33.1%) patients, a definite diagnosis could only be reached with the combination of both techniques. The diagnostic yield of forceps biopsy was better than catheter aspiration in infiltrates (p = 0.027), but was no different in nodules or masses (p = 0.09). Suction catheter aspiration is a useful technique of bronchoscopic tissue sampling. The combination of catheter aspiration and forceps biopsy results in a higher diagnostic yield than either method used alone.
Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara
2014-08-01
Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.
Structure and Computation in Immunoreagent Design: From Diagnostics to Vaccines.
Gourlay, Louise; Peri, Claudio; Bolognesi, Martino; Colombo, Giorgio
2017-12-01
Novel immunological tools for efficient diagnosis and treatment of emerging infections are urgently required. Advances in the diagnostic and vaccine development fields are continuously progressing, with reverse vaccinology and structural vaccinology (SV) methods for antigen identification and structure-based antigen (re)design playing increasingly relevant roles. SV, in particular, is predicted to be the front-runner in the future development of diagnostics and vaccines targeting challenging diseases such as AIDS and cancer. We review state-of-the-art methodologies for structure-based epitope identification and antigen design, with specific applicative examples. We highlight the implications of such methods for the engineering of biomolecules with improved immunological properties, potential diagnostic and/or therapeutic uses, and discuss the perspectives of structure-based rational design for the production of advanced immunoreagents. Copyright © 2017 Elsevier Ltd. All rights reserved.
Efficient logistic regression designs under an imperfect population identifier.
Albert, Paul S; Liu, Aiyi; Nansel, Tonja
2014-03-01
Motivated by actual study designs, this article considers efficient logistic regression designs where the population is identified with a binary test that is subject to diagnostic error. We consider the case where the imperfect test is obtained on all participants, while the gold standard test is measured on a small chosen subsample. Under maximum-likelihood estimation, we evaluate the optimal design in terms of sample selection as well as verification. We show that there may be substantial efficiency gains by choosing a small percentage of individuals who test negative on the imperfect test for inclusion in the sample (e.g., verifying 90% test-positive cases). We also show that a two-stage design may be a good practical alternative to a fixed design in some situations. Under optimal and nearly optimal designs, we compare maximum-likelihood and semi-parametric efficient estimators under correct and misspecified models with simulations. The methodology is illustrated with an analysis from a diabetes behavioral intervention trial. © 2013, The International Biometric Society.
Yi, Shengzhen; Zhang, Zhe; Huang, Qiushi; Zhang, Zhong; Mu, Baozhong; Wang, Zhanshan; Fang, Zhiheng; Wang, Wei; Fu, Sizu
2016-10-01
Because grazing-incidence Kirkpatrick-Baez (KB) microscopes have better resolution and collection efficiency than pinhole cameras, they have been widely used for x-ray imaging diagnostics of laser inertial confinement fusion. The assembly and adjustment of a multichannel KB microscope must meet stringent requirements for image resolution and reproducible alignment. In the present study, an eight-channel KB microscope was developed for diagnostics by imaging self-emission x-rays with a framing camera at the Shenguang-II Update (SGII-Update) laser facility. A consistent object field of view is ensured in the eight channels using an assembly method based on conical reference cones, which also allow the intervals between the eight images to be tuned to couple with the microstrips of the x-ray framing camera. The eight-channel KB microscope was adjusted via real-time x-ray imaging experiments in the laboratory. This paper describes the details of the eight-channel KB microscope, its optical and multilayer design, the assembly and alignment methods, and results of imaging in the laboratory and at the SGII-Update.
Climate Model Diagnostic Analyzer
NASA Technical Reports Server (NTRS)
Lee, Seungwon; Pan, Lei; Zhai, Chengxing; Tang, Benyang; Kubar, Terry; Zhang, Zia; Wang, Wei
2015-01-01
The comprehensive and innovative evaluation of climate models with newly available global observations is critically needed for the improvement of climate model current-state representation and future-state predictability. A climate model diagnostic evaluation process requires physics-based multi-variable analyses that typically involve large-volume and heterogeneous datasets, making them both computation- and data-intensive. With an exploratory nature of climate data analyses and an explosive growth of datasets and service tools, scientists are struggling to keep track of their datasets, tools, and execution/study history, let alone sharing them with others. In response, we have developed a cloud-enabled, provenance-supported, web-service system called Climate Model Diagnostic Analyzer (CMDA). CMDA enables the physics-based, multivariable model performance evaluations and diagnoses through the comprehensive and synergistic use of multiple observational data, reanalysis data, and model outputs. At the same time, CMDA provides a crowd-sourcing space where scientists can organize their work efficiently and share their work with others. CMDA is empowered by many current state-of-the-art software packages in web service, provenance, and semantic search.
Schell, Greggory J; Lavieri, Mariel S; Helm, Jonathan E; Liu, Xiang; Musch, David C; Van Oyen, Mark P; Stein, Joshua D
2014-08-01
To determine whether dynamic and personalized schedules of visual field (VF) testing and intraocular pressure (IOP) measurements result in an improvement in disease progression detection compared with fixed interval schedules for performing these tests when evaluating patients with open-angle glaucoma (OAG). Secondary analyses using longitudinal data from 2 randomized controlled trials. A total of 571 participants from the Advanced Glaucoma Intervention Study (AGIS) and the Collaborative Initial Glaucoma Treatment Study (CIGTS). Perimetric and tonometric data were obtained for AGIS and CIGTS trial participants and used to parameterize and validate a Kalman filter model. The Kalman filter updates knowledge about each participant's disease dynamics as additional VF tests and IOP measurements are obtained. After incorporating the most recent VF and IOP measurements, the model forecasts each participant's disease dynamics into the future and characterizes the forecasting error. To determine personalized schedules for future VF tests and IOP measurements, we developed an algorithm by combining the Kalman filter for state estimation with the predictive power of logistic regression to identify OAG progression. The algorithm was compared with 1-, 1.5-, and 2-year fixed interval schedules of obtaining VF and IOP measurements. Length of diagnostic delay in detecting OAG progression, efficiency of detecting progression, and number of VF and IOP measurements needed to assess for progression. Participants were followed in the AGIS and CIGTS trials for a mean (standard deviation) of 6.5 (2.8) years. Our forecasting model achieved a 29% increased efficiency in identifying OAG progression (P<0.0001) and detected OAG progression 57% sooner (reduced diagnostic delay) (P = 0.02) than following a fixed yearly monitoring schedule, without increasing the number of VF tests and IOP measurements required. The model performed well for patients with mild and advanced disease. The model performed significantly more testing of patients who exhibited OAG progression than nonprogressing patients (1.3 vs. 1.0 tests per year; P<0.0001). Use of dynamic and personalized testing schedules can enhance the efficiency of OAG progression detection and reduce diagnostic delay compared with yearly fixed monitoring intervals. If further validation studies confirm these findings, such algorithms may be able to greatly enhance OAG management. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
[Current Progresses in Developing PET Radiopharmaceuticals for Patients in the Czech Republic].
Adam, J; Demlová, R; Řehák, Z
In Masaryk Memorial Cancer Institute (MMCI), there is a long-running intensive joint effort of the RECAMO project and commercial entities, involving mainly clinical evaluations of state-of-the-art PET radiopharmaceuticals leading to their future availability for Czech physicians and their patients. Recently, the PET tracers [11C]methionine and [18F]fluorocholine, among others, were developed in this cooperation, both of them tracers with high importance for oncologic positron emission tomography diagnostics. [11C]methionine, labeled by carbon-11 with a half-life of 20 min, is a proteosynthesis marker used primarily for brain tumor visualization, whereas [18F]fluorocholine, labeled by fluorine-18 with a half-life of 109 min, is a marker of synthesis of cellular membranes and cell proliferation, its primary use being PET diagnostics of prostate carcinoma. The results of clinical evaluations of both PET radiopharmaceuticals, performed on the basis of parameters agreed and approved beforehand in cooperation of MMCI, RECAMO and the manufacturer of said radiopharmaceuticals, aimed to prove the efficiency and suitability of both compounds for oncologic PET diagnostics for said tumors. In both cases, the radiopharmaceuticals were evaluated in regard to their major use. The obtained results prove the benefits and efficiency of both compounds in PET diagnostics of respective tumors. The results, in the form of clinical evaluation reports, will be used as part of the documentation required for marketing authorization of these compounds for use in the Czech Republic.Key words: positron emission tomography - radiopharmaceuticals - L-methyl-11C-methionine - 18F-fluorocholineThis work was supported by the project MEYS - NPS I - LO1413.The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study.The Editorial Board declares that the manuscript met the ICMJE recommendation for biomedical papers.Submitted: 10. 6. 2016Accepted: 17. 6. 2016.
Kuru, Kaya; Niranjan, Mahesan; Tunca, Yusuf; Osvank, Erhan; Azim, Tayyaba
2014-10-01
In general, medical geneticists aim to pre-diagnose underlying syndromes based on facial features before performing cytological or molecular analyses where a genotype-phenotype interrelation is possible. However, determining correct genotype-phenotype interrelationships among many syndromes is tedious and labor-intensive, especially for extremely rare syndromes. Thus, a computer-aided system for pre-diagnosis can facilitate effective and efficient decision support, particularly when few similar cases are available, or in remote rural districts where diagnostic knowledge of syndromes is not readily available. The proposed methodology, visual diagnostic decision support system (visual diagnostic DSS), employs machine learning (ML) algorithms and digital image processing techniques in a hybrid approach for automated diagnosis in medical genetics. This approach uses facial features in reference images of disorders to identify visual genotype-phenotype interrelationships. Our statistical method describes facial image data as principal component features and diagnoses syndromes using these features. The proposed system was trained using a real dataset of previously published face images of subjects with syndromes, which provided accurate diagnostic information. The method was tested using a leave-one-out cross-validation scheme with 15 different syndromes, each of comprised 5-9 cases, i.e., 92 cases in total. An accuracy rate of 83% was achieved using this automated diagnosis technique, which was statistically significant (p<0.01). Furthermore, the sensitivity and specificity values were 0.857 and 0.870, respectively. Our results show that the accurate classification of syndromes is feasible using ML techniques. Thus, a large number of syndromes with characteristic facial anomaly patterns could be diagnosed with similar diagnostic DSSs to that described in the present study, i.e., visual diagnostic DSS, thereby demonstrating the benefits of using hybrid image processing and ML-based computer-aided diagnostics for identifying facial phenotypes. Copyright © 2014. Published by Elsevier B.V.
Ramsay, A; Steingart, K R; Cunningham, J; Pai, M
2011-10-01
Using the example of an international collaboration on tuberculosis (TB) diagnostics, we mapped the key stages and stakeholders involved in translating research into global policies. In our experience, the process begins with advocacy for high-quality, policy-relevant research and appropriate funding. Following the assessment of current policy and the identification of key study areas, policy-relevant research questions need to be formulated and prioritised. It is important that a framework for translating evidence into policy at the target policymaking level, in this case global, is available to researchers. This ensures that research questions, study designs and research standards are appropriate to the type and quality of evidence required. The framework may evolve during the period of research and, as evidence requirements may change, vigilance is required. Formal and informal multi-stakeholder partnerships, as well as information sharing through extensive networking, facilitate efficient building of a broad evidence base. Coordination of activities by an international, neutral body with strong convening powers is important, as is regular interaction with policy makers. It is recognised that studies on diagnostic accuracy provide weak evidence that a new diagnostic will improve patient care when implemented to scale in routine settings. This may be one reason why there has been poor uptake of new tools by national TB control programmes despite global policy recommendations. Stronger engagement with national policy makers and donors during the research-intopolicy process may be needed to ensure that their evidence requirements are met and that global policies translate into national policies. National policies are central to translating global policies into practice.
NASA Technical Reports Server (NTRS)
1993-01-01
The Marshall Space Flight Center is responsible for the development and management of advanced launch vehicle propulsion systems, including the Space Shuttle Main Engine (SSME), which is presently operational, and the Space Transportation Main Engine (STME) under development. The SSME's provide high performance within stringent constraints on size, weight, and reliability. Based on operational experience, continuous design improvement is in progress to enhance system durability and reliability. Specialized data analysis and interpretation is required in support of SSME and advanced propulsion system diagnostic evaluations. Comprehensive evaluation of the dynamic measurements obtained from test and flight operations is necessary to provide timely assessment of the vibrational characteristics indicating the operational status of turbomachinery and other critical engine components. Efficient performance of this effort is critical due to the significant impact of dynamic evaluation results on ground test and launch schedules, and requires direct familiarity with SSME and derivative systems, test data acquisition, and diagnostic software. Detailed analysis and evaluation of dynamic measurements obtained during SSME and advanced system ground test and flight operations was performed including analytical/statistical assessment of component dynamic behavior, and the development and implementation of analytical/statistical models to efficiently define nominal component dynamic characteristics, detect anomalous behavior, and assess machinery operational condition. In addition, the SSME and J-2 data will be applied to develop vibroacoustic environments for advanced propulsion system components, as required. This study will provide timely assessment of engine component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. This contract will be performed through accomplishment of negotiated task orders.
Tsuda, Takumi; Kaibori, Masaki; Hishikawa, Hidehiko; Nakatake, Richi; Okumura, Tadayoshi; Ozeki, Eiichi; Hara, Isao; Morimoto, Yuji; Yoshii, Kengo; Kon, Masanori
2017-01-01
Anticancer agents and operating procedures have been developed for hepatocellular carcinoma (HCC) patients, but their prognosis remains poor. It is necessary to develop novel diagnostic and therapeutic strategies for HCC to improve its prognosis. Lactosome is a core-shell-type polymeric micelle, and enclosing labeling or anticancer agents into this micelle enables drug delivery. In this study, we investigated the diagnostic and therapeutic efficacies of indocyanine green (ICG)-loaded lactosome for near-infrared fluorescence (NIF) imaging and photodynamic therapy (PDT) for HCC. The human HCC cell line HuH-7 was treated with ICG or ICG-lactosome, followed by PDT, and the cell viabilities were measured (in vitro PDT efficiency). For NIF imaging, HuH-7 cells were subcutaneously transplanted into BALB/c nude mice, followed by intravenous administration of ICG or ICG-lactosome. The transplanted animals were treated with PDT, and the antineoplastic effects were analyzed (in vivo PDT efficiency). PDT had toxic effects on HuH-7 cells treated with ICG-lactosome, but not ICG alone. NIF imaging revealed that the fluorescence of tumor areas in ICG-lactosome-treated animals was higher than that of contralateral regions at 24 h after injection and thereafter. PDT exerted immediate and continuous phototoxic effects in the transplanted mice treated with ICG-lactosome. Our results demonstrate that ICG-lactosome accumulated in xenograft tumors, and that PDT had antineoplastic effects on these malignant implants. NIF imaging and PDT with ICG-lactosome could be useful diagnostic and/or therapeutic strategies for HCC.
Décary, Simon; Feldman, Debbie; Frémont, Pierre; Pelletier, Jean-Pierre; Martel-Pelletier, Johanne; Fallaha, Michel; Pelletier, Bruno; Belzile, Sylvain; Sylvestre, Marie-Pierre; Vendittoli, Pascal-André; Desmeules, François
2018-05-21
The aim of the present study was to assess the validity of clusters combining history elements and physical examination tests to diagnose symptomatic knee osteoarthritis (SOA) compared with other knee disorders. This was a prospective diagnostic accuracy study, in which 279 consecutive patients consulting for a knee complaint were assessed. History elements and standardized physical examination tests were obtained independently by a physiotherapist and compared with an expert physician's composite diagnosis, including clinical examination and imaging. Recursive partitioning was used to develop diagnostic clusters for SOA. Diagnostic accuracy measures were calculated, including sensitivity, specificity, and positive and negative likelihood ratios (LR+/-), with associated 95% confidence intervals (CIs). A total of 129 patients had a diagnosis of SOA (46.2%). Most cases (76%) had combined tibiofemoral and patellofemoral knee OA and 63% had radiological Kellgren-Lawrence grades of 2 or 3. Different combinations of history elements and physical examination tests were used in clusters accurately to discriminate SOA from other knee disorders. These included age of patients, body mass index, presence of valgus/varus knee misalignment, palpable knee crepitus and limited passive knee extension. Two clusters to rule in SOA reached an LR+ of 13.6 (95% CI 6.5 to 28.4) and three clusters to rule out SOA reached an LR- of 0.11 (95% CI 0.06 to 0.20). Diagnostic clusters combining history elements and physical examination tests were able to support the differential diagnosis of SOA compared with various knee disorders without relying systematically on imaging. This could support primary care clinicians' role in the efficient management of these patients. Copyright © 2018 John Wiley & Sons, Ltd.
Youl, Philippa H; Aitken, Joanne F; Turrell, Gavin; Chambers, Suzanne K; Dunn, Jeffrey; Pyke, Christopher; Baade, Peter D
2016-11-19
Delays in diagnosing breast cancer (BC) can lead to poorer outcomes. We investigated factors related to the diagnostic interval in a population-based cohort of 3202 women diagnosed with BC in Queensland, Australia. Interviews ascertained method of detection and dates of medical/procedural appointments, and clinical information was obtained from medical records. Time intervals were calculated from self-recognition of symptoms (symptom-detected) or mammogram (screen-detected) to diagnosis (diagnostic interval (DI)). The cohort included 1560 women with symptom-detected and 1642 with screen-detected BC. Symptom-detected women had higher odds of DI of >60 days if they were Indigenous (OR = 3.12, 95% CI = 1.40, 6.98); lived in outer regional (OR = 1.50, 95% CI = 1.09, 2.06) or remote locations (OR = 2.46, 95% CI = 1.39, 4.38); or presented with a "non-lump" symptom (OR = 1.84, 95% CI = 1.43, 2.36). For screen-detected BC, women who were Indigenous (OR = 2.36, 95% CI = 1.03, 5.80); lived in remote locations (OR = 2.35, 95% CI = 1.24, 4.44); or disadvantaged areas (OR = 1.69, 95% CI = 1.17, 2.43) and attended a public screening facility (OR = 2.10, 95% CI = 1.40, 3.17) had higher odds of DI > 30 days. Our study indicates a disadvantage in terms of DI for rural, disadvantaged and Indigenous women. Difficulties in accessing primary care and diagnostic services are evident. There is a need to identify and implement an efficient and effective model of care to minimize avoidable longer diagnostic intervals.
Korop, Oleg A; Lenskykh, Sergiy V
2018-01-01
Introduction: Modern changes in the health care system of Ukraine are focused on financial support in providing medical and diagnostic care to the population and are based on deep and consistent structural and functional transformations. They are aimed at providing adequate quality care, which is the main target function and a principal criterion for operation of health care system. The urgency of this problem is increasing in the context of reforming the health care system and global changes in the governmental financial guarantees for the provision of medical services to the population. The aim of the work is to provide theoretical grounds for a structural and functional model of quality assurance of radiation diagnostics at all levels of medical care given to the population under the current health care reform in Ukraine. Materials and methods: The object of the study is organizing the operation of the radiation diagnostic service; the information is based on the actual data on the characteristics of radiation diagnosis at different levels of medical care provision. Methods of systematic approach, system analysis and structural and functional analysis of the operating system of radiation diagnostics are used. Review: The basis of the quality assurance model is the cyclical process, which includes the stages of the problem identifition, planning of its solution, organization of the system for implementation of decisions, monitoring the quality management process of the radiation diagnostics, and factors influencing the quality of the radiation diagnostics service. These factors include the quality of the structure, process, results, organization of management and control of current processes and the results of radiation diagnostics management. Conclusions: The advantages of the proposed model for ensuring the quality of the radiation diagnostics service are its systemacy and complexity, elimination of identified defects and deficiencies, and achievement of profitability through modern redistribution and use of existing resources of the health care system. The results of adequate service quality management activities in radiation diagnostics are the improvement of organizational and economic principles along with legislative regulation, the implementation of a modern system of radiation diagnostics in the state health care at the national and regional levels, the increase of the accessibility, quality and efficiency of the radiation diagnostics service.
Evolving models for medical physics education and training: a global perspective.
Sprawls, P
2008-01-01
There is a significant need for high-quality medical physics education and training in all countries to support effective and safe use of modern medical technology for both diagnostic and treatment purposes. This is, and will continue to be, achieved using appropriate technology to increase both the effectiveness and efficiency of educational activities everywhere in the world. While the applications of technology to education and training are relatively new, the successful applications are based on theories and principles of the learning process developed by two pioneers in the field, Robert Gagne and Edgar Dale.The work of Gagne defines the different levels of learning that can occur and is used to show the types and levels of learning that are required for the application of physics and engineering principles to achieve appropriate diagnostic and therapeutic results from modern technology. The learning outcomes are determined by the effectiveness of the learning activity or experience. The extensive work of Dale as formulated in his Cone of Experience relates the effectiveness to the efficiency of educational activities. A major challenge in education is the development and conduction of learning activities (classroom discussions, laboratory and applied experiences, individual study, etc) that provide an optimum balance between effectiveness and efficiency. New and evolving models of the educational process use technology as the infrastructure to support education that is both more effective and efficient.The goal is to use technology to enhance human performance for both learners (students) and learning facilitators (teachers). A major contribution to global education is the trend in the development of shared educational resources. Two models of programs to support this effort with open and free shared resources are Physical Principles of Medical Imaging Online (http://www.sprawls.org/resources) and AAPM Continuing Education Courses (http://www.aapm.org/international).
Evolving models for medical physics education and training: a global perspective
Sprawls, P
2008-01-01
There is a significant need for high-quality medical physics education and training in all countries to support effective and safe use of modern medical technology for both diagnostic and treatment purposes. This is, and will continue to be, achieved using appropriate technology to increase both the effectiveness and efficiency of educational activities everywhere in the world. While the applications of technology to education and training are relatively new, the successful applications are based on theories and principles of the learning process developed by two pioneers in the field, Robert Gagne and Edgar Dale. The work of Gagne defines the different levels of learning that can occur and is used to show the types and levels of learning that are required for the application of physics and engineering principles to achieve appropriate diagnostic and therapeutic results from modern technology. The learning outcomes are determined by the effectiveness of the learning activity or experience. The extensive work of Dale as formulated in his Cone of Experience relates the effectiveness to the efficiency of educational activities. A major challenge in education is the development and conduction of learning activities (classroom discussions, laboratory and applied experiences, individual study, etc) that provide an optimum balance between effectiveness and efficiency. New and evolving models of the educational process use technology as the infrastructure to support education that is both more effective and efficient. The goal is to use technology to enhance human performance for both learners (students) and learning facilitators (teachers). A major contribution to global education is the trend in the development of shared educational resources. Two models of programs to support this effort with open and free shared resources are Physical Principles of Medical Imaging Online (http://www.sprawls.org/resources) and AAPM Continuing Education Courses (http://www.aapm.org/international). PMID:21614309
Chasing helminths and their economic impact on farmed ruminants.
Charlier, Johannes; van der Voort, Mariska; Kenyon, Fiona; Skuce, Philip; Vercruysse, Jozef
2014-07-01
Global agriculture will be required to intensify production from a shrinking natural resource base. Helminth infections of ruminants are a major constraint on efficient livestock production. The current challenge is to develop diagnostic methods that detect the production impact of helminth infections on farms in order to target control measures and contribute to the global challenge of preserving food security. We review here our understanding of the effects of helminth infections and control practices on productivity and the diagnostic tools that can inform on this. By combining advances in helminth laboratory diagnostics and animal health economics, sustainable management of helminth infections can be integrated into the whole-farm economic context. Copyright © 2014 Elsevier Ltd. All rights reserved.
Role of Big Data and Machine Learning in Diagnostic Decision Support in Radiology.
Syeda-Mahmood, Tanveer
2018-03-01
The field of diagnostic decision support in radiology is undergoing rapid transformation with the availability of large amounts of patient data and the development of new artificial intelligence methods of machine learning such as deep learning. They hold the promise of providing imaging specialists with tools for improving the accuracy and efficiency of diagnosis and treatment. In this article, we will describe the growth of this field for radiology and outline general trends highlighting progress in the field of diagnostic decision support from the early days of rule-based expert systems to cognitive assistants of the modern era. Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.
[Current problems of ophthalmologic examination in automobile drivers].
Chernyshova, S G
2002-01-01
The article deals with major aspects of eye examination in automobile drivers, with main drawbacks of occupational selection, absence of efficient diagnostic devices, with various approaches to inspection of color perception.
NASA Astrophysics Data System (ADS)
Iakovleva, E. V.; Momot, B. A.
2017-10-01
The object of this study is to develop a power plant and an electric propulsion control system for autonomous remotely controlled vessels. The tasks of the study are as follows: to assess remotely controlled vessels usage reasonability, to define the requirements for this type of vessel navigation. In addition, the paper presents the analysis of technical diagnostics systems. The developed electric propulsion control systems for vessels should provide improved reliability and efficiency of the propulsion complex to ensure the profitability of remotely controlled vessels.
Uchiyama, Mayara Klimuk; Toma, Sergio Hiroshi; Rodrigues, Stephen Fernandes; Shimada, Ana Lucia Borges; Loiola, Rodrigo Azevedo; Cervantes Rodríguez, Hernán Joel; Oliveira, Pedro Vitoriano; Luz, Maciel Santos; Rabbani, Said Rahnamaye; Toma, Henrique Eisi; Poliselli Farsky, Sandra Helena; Araki, Koiti
2015-01-01
Fully dispersible, cationic ultrasmall (7 nm diameter) superparamagnetic iron oxide nanoparticles, exhibiting high relaxivity (178 mM−1s−1 in 0.47 T) and no acute or subchronic toxicity in Wistar rats, were studied and their suitability as contrast agents for magnetic resonance imaging and material for development of new diagnostic and treatment tools demonstrated. After intravenous injection (10 mg/kg body weight), they circulated throughout the vascular system causing no microhemorrhage or thrombus, neither inflammatory processes at the mesentery vascular bed and hepatic sinusoids (leukocyte rolling, adhesion, or migration as evaluated by intravital microscopy), but having been spontaneously concentrated in the liver, spleen, and kidneys, they caused strong negative contrast. The nanoparticles are cleared from kidneys and bladder in few days, whereas the complete elimination from liver and spleen occurred only after 4 weeks. Ex vivo studies demonstrated that cationic ultrasmall superparamagnetic iron oxide nanoparticles caused no effects on hepatic and renal enzymes dosage as well as on leukocyte count. In addition, they were readily concentrated in rat thigh by a magnet showing its potential as magnetically targeted carriers of therapeutic and diagnostic agents. Summarizing, cationic ultrasmall superparamagnetic iron oxide nanoparticles are nontoxic and efficient magnetic resonance imaging contrast agents useful as platform for the development of new materials for application in theranostics. PMID:26251595
Curk, Franck; Ancillo, Gema; Ollitrault, Frédérique; Perrier, Xavier; Jacquemoud-Collet, Jean-Pierre; Garcia-Lor, Andres; Navarro, Luis; Ollitrault, Patrick
2015-01-01
Most cultivated Citrus species originated from interspecific hybridisation between four ancestral taxa (C. reticulata, C. maxima, C. medica, and C. micrantha) with limited further interspecific recombination due to vegetative propagation. This evolution resulted in admixture genomes with frequent interspecific heterozygosity. Moreover, a major part of the phenotypic diversity of edible citrus results from the initial differentiation between these taxa. Deciphering the phylogenomic structure of citrus germplasm is therefore essential for an efficient utilization of citrus biodiversity in breeding schemes. The objective of this work was to develop a set of species-diagnostic single nucleotide polymorphism (SNP) markers for the four Citrus ancestral taxa covering the nine chromosomes, and to use these markers to infer the phylogenomic structure of secondary species and modern cultivars. Species-diagnostic SNPs were mined from 454 amplicon sequencing of 57 gene fragments from 26 genotypes of the four basic taxa. Of the 1,053 SNPs mined from 28,507 kb sequence, 273 were found to be highly diagnostic for a single basic taxon. Species-diagnostic SNP markers (105) were used to analyse the admixture structure of varieties and rootstocks. This revealed C. maxima introgressions in most of the old and in all recent selections of mandarins, and suggested that C. reticulata × C. maxima reticulation and introgression processes were important in edible mandarin domestication. The large range of phylogenomic constitutions between C. reticulata and C. maxima revealed in mandarins, tangelos, tangors, sweet oranges, sour oranges, grapefruits, and orangelos is favourable for genetic association studies based on phylogenomic structures of the germplasm. Inferred admixture structures were in agreement with previous hypotheses regarding the origin of several secondary species and also revealed the probable origin of several acid citrus varieties. The developed species-diagnostic SNP marker set will be useful for systematic estimation of admixture structure of citrus germplasm and for diverse genetic studies. PMID:25973611
NASA Astrophysics Data System (ADS)
Kong, Changduk; Lim, Semyeong
2011-12-01
Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.
Curk, Franck; Ancillo, Gema; Ollitrault, Frédérique; Perrier, Xavier; Jacquemoud-Collet, Jean-Pierre; Garcia-Lor, Andres; Navarro, Luis; Ollitrault, Patrick
2015-01-01
Most cultivated Citrus species originated from interspecific hybridisation between four ancestral taxa (C. reticulata, C. maxima, C. medica, and C. micrantha) with limited further interspecific recombination due to vegetative propagation. This evolution resulted in admixture genomes with frequent interspecific heterozygosity. Moreover, a major part of the phenotypic diversity of edible citrus results from the initial differentiation between these taxa. Deciphering the phylogenomic structure of citrus germplasm is therefore essential for an efficient utilization of citrus biodiversity in breeding schemes. The objective of this work was to develop a set of species-diagnostic single nucleotide polymorphism (SNP) markers for the four Citrus ancestral taxa covering the nine chromosomes, and to use these markers to infer the phylogenomic structure of secondary species and modern cultivars. Species-diagnostic SNPs were mined from 454 amplicon sequencing of 57 gene fragments from 26 genotypes of the four basic taxa. Of the 1,053 SNPs mined from 28,507 kb sequence, 273 were found to be highly diagnostic for a single basic taxon. Species-diagnostic SNP markers (105) were used to analyse the admixture structure of varieties and rootstocks. This revealed C. maxima introgressions in most of the old and in all recent selections of mandarins, and suggested that C. reticulata × C. maxima reticulation and introgression processes were important in edible mandarin domestication. The large range of phylogenomic constitutions between C. reticulata and C. maxima revealed in mandarins, tangelos, tangors, sweet oranges, sour oranges, grapefruits, and orangelos is favourable for genetic association studies based on phylogenomic structures of the germplasm. Inferred admixture structures were in agreement with previous hypotheses regarding the origin of several secondary species and also revealed the probable origin of several acid citrus varieties. The developed species-diagnostic SNP marker set will be useful for systematic estimation of admixture structure of citrus germplasm and for diverse genetic studies.
Spectral analysis of major heart tones
NASA Astrophysics Data System (ADS)
Lejkowski, W.; Dobrowolski, A. P.; Majka, K.; Olszewski, R.
2018-04-01
The World Health Organization (WHO) figures clearly indicate that cardiovascular disease is the most common cause of death and disability in the world. Early detection of cardiovascular pathologies may contribute to reducing such a high mortality rate. Auscultatory examination is one of the first and most important step in cardiologic diagnostics. Unfortunately, proper diagnosis is closely related to long-term practice and medical experience. The article presents the author's system of recording phonocardiograms and the way of saving data, as well as the outline of the analysis algorithm, which will allow to assign a case to a patient with heart failure or healthy voluntaries' with a certain high probability. The results of a pilot study of phonocardiographic signals were also presented as an introduction to further research aimed at the development of an efficient diagnostic algorithm based on spectral analysis of the heart tone.
3D equilibrium reconstruction with islands
Cianciosa, M.; Hirshman, S. P.; Seal, S. K.; ...
2018-02-15
This study presents the development of a 3D equilibrium reconstruction tool and the results of the first-ever reconstruction of an island equilibrium. The SIESTA non-nested equilibrium solver has been coupled to the V3FIT 3D equilibrium reconstruction code. Computed from a coupled VMEC and SIESTA model, synthetic signals are matched to measured signals by finding an optimal set of equilibrium parameters. By using the normalized pressure in place of normalized flux, non-equilibrium quantities needed by diagnostic signals can be efficiently mapped to the equilibrium. The effectiveness of this tool is demonstrated by reconstructing an island equilibrium of a DIII-D inner wallmore » limited L-mode case with an n = 1 error field applied. Finally, flat spots in Thomson and ECE temperature diagnostics show the reconstructed islands have the correct size and phase.« less
3D equilibrium reconstruction with islands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cianciosa, M.; Hirshman, S. P.; Seal, S. K.
This study presents the development of a 3D equilibrium reconstruction tool and the results of the first-ever reconstruction of an island equilibrium. The SIESTA non-nested equilibrium solver has been coupled to the V3FIT 3D equilibrium reconstruction code. Computed from a coupled VMEC and SIESTA model, synthetic signals are matched to measured signals by finding an optimal set of equilibrium parameters. By using the normalized pressure in place of normalized flux, non-equilibrium quantities needed by diagnostic signals can be efficiently mapped to the equilibrium. The effectiveness of this tool is demonstrated by reconstructing an island equilibrium of a DIII-D inner wallmore » limited L-mode case with an n = 1 error field applied. Finally, flat spots in Thomson and ECE temperature diagnostics show the reconstructed islands have the correct size and phase.« less
Residence as a Diagnostic and Therapeutic Area - A Smart Home Approach.
Mielke, Corinna; Voss, Thorsten; Haux, Reinhold
2017-01-01
The "research apartment Halberstadtstraße" (HSS) in Braunschweig, Germany, is the attempt to realize a personal living environment as a room for diagnostics and therapy with the support of health-enabling and ambient assistive technologies (HEAAT). As a research tool, the HSS will enable the efficient implementation of new HEAAT and help in evaluating these under controlled real-life conditions. This new research tool will therefore be the missing link between artificial laboratory and complete real-life conditions. For a defined period, selected subjects can live in the HSS and experience the benefit of such a "Smart Home". The academic support in a real-life controlled living-environment enables continuous monitoring of behavior patterns and habits of healthy and ill persons, evaluation of new HEAAT, and conduction of requirements analysis and acceptance studies.
Zhang, Lu; Zhou, Ping; Deng, Jin; Tian, Shuangming; Qian, Ying; Wu, Xiaomin; Ma, Shuhua; Li, Jiale
2014-12-01
To evaluate the diagnostic performance of conventional ultrasound, compression elastography (CE) and acoustic radiation force impulse imaging (ARFI) in differential diagnosis of benign and malignant breast tumors. A total of 98 patients with liver lesions were included in the study. The images of conventional ultrasound, CE and the values of virtual touch tissue quantification (VTQ) of breast lesions were obtained. The diagnostic performance of conventional ultrasound, CE and ARFI were assessed by using pathology as the gold standard, and then evaluate the diagnosis efficiency of these three approaches in differential diagnosing benign and malignant breast tumors. The specificity, sensitivity and accuracy in the diagnosis of malignant breast tumors for conventional ultrasound were 80.0%, 81.1% and 81.7%, respectively, whereas for CE elastic score were 85.7%, 86.7% and 86.3%, respectively. With a cutoff value of 3.71 for the SR, the sensitivity, specificity, accuracy in diagnosis of malignant breast tumors were 97.1%, 83.3% and 88.4%, respectively. With a cutoff value of 3.78 m/s for VTQ, the sensitivity, specificity, accuracy in diagnosis of malignant breast tumors were 94.3%, 91.7% and 92.6%, respectively. The difference in diagnosis efficiency among ARFI, CE and conventional ultrasound in differential diagnosis of benign and malignant breast tumors was significant (P< 0.05). Conventional ultrasound, CE and ARFI are all useful for the differential diagnosis of benign and malignant breast tumors. But the diagnosis efficiency of ARFI is superior to CE and conventional ultrasound. The three approaches can help each other in differential diagnosis of benign and malignant breast tumors.
Schouten, Henrike J; Koek, Huiberdina L; Oudega, Ruud; van Delden, Johannes J M; Moons, Karel G M; Geersing, Geert-Jan
2015-02-01
We aimed to validate the Oudega diagnostic decision rule-which was developed and validated among younger aged primary care patients-to rule-out deep vein thrombosis (DVT) in frail older outpatients. In older patients (>60 years, either community dwelling or residing in nursing homes) with clinically suspected DVT, physicians recorded the score on the Oudega rule and d-dimer test. DVT was confirmed with a composite reference standard including ultrasonography examination and 3-month follow-up. The proportion of patients with a very low probability of DVT according to the Oudega rule (efficiency), and the proportion of patients with symptomatic venous thromboembolism during 3 months follow-up within this 'very low risk' group (failure rate) was calculated. DVT occurred in 164 (47%) of the 348 study participants (mean age 81 years, 85% residing in nursing homes). The probability of DVT was very low in 69 patients (Oudega score ≤3 points plus a normal d-dimer test; efficiency 20%) of whom four had non-fatal DVT (failure rate 5.8%; 2.3-14%). With a simple revised version of the Oudega rule for older suspected patients, 43 patients had a low risk of DVT (12% of the total population) of whom only one had DVT (failure rate 2.3%; 0.4-12%). In older suspected patients, application of the original Oudega rule to exclude DVT resulted in a higher failure rate as compared to previous studies. A revised and simplified Oudega strategy specifically developed for elderly suspected patients resulted in a lower failure rate though at the expense of a lower efficiency. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Rosen, Amy K; Loveland, Susan A; Rakovski, Carter C; Christiansen, Cindy L; Berlowitz, Dan R
2003-01-01
Although case-mix adjustment is critical for provider profiling, little is known regarding whether different case-mix measures affect assessments of provider efficiency. We examine whether two case-mix measures, Adjusted Clinical Groups (ACGs) and Diagnostic Cost Groups (DCGs), result in different assessments of efficiency across service networks within the Department of Veterans Affairs (VA). Three profiling indicators examine variation in resource use. Although results from the ACGs and DCGs generally agree on which networks have greater or lesser efficiency than average, assessments of individual network efficiency vary depending upon the case-mix measure used. This suggests that caution should be used so that providers are not misclassified based on reported efficiency.
Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A; Chauhan, Sunanda
2018-01-01
Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material.
Roldan, Stephanie M
2017-01-01
One of the fundamental goals of object recognition research is to understand how a cognitive representation produced from the output of filtered and transformed sensory information facilitates efficient viewer behavior. Given that mental imagery strongly resembles perceptual processes in both cortical regions and subjective visual qualities, it is reasonable to question whether mental imagery facilitates cognition in a manner similar to that of perceptual viewing: via the detection and recognition of distinguishing features. Categorizing the feature content of mental imagery holds potential as a reverse pathway by which to identify the components of a visual stimulus which are most critical for the creation and retrieval of a visual representation. This review will examine the likelihood that the information represented in visual mental imagery reflects distinctive object features thought to facilitate efficient object categorization and recognition during perceptual viewing. If it is the case that these representational features resemble their sensory counterparts in both spatial and semantic qualities, they may well be accessible through mental imagery as evaluated through current investigative techniques. In this review, methods applied to mental imagery research and their findings are reviewed and evaluated for their efficiency in accessing internal representations, and implications for identifying diagnostic features are discussed. An argument is made for the benefits of combining mental imagery assessment methods with diagnostic feature research to advance the understanding of visual perceptive processes, with suggestions for avenues of future investigation.
Roldan, Stephanie M.
2017-01-01
One of the fundamental goals of object recognition research is to understand how a cognitive representation produced from the output of filtered and transformed sensory information facilitates efficient viewer behavior. Given that mental imagery strongly resembles perceptual processes in both cortical regions and subjective visual qualities, it is reasonable to question whether mental imagery facilitates cognition in a manner similar to that of perceptual viewing: via the detection and recognition of distinguishing features. Categorizing the feature content of mental imagery holds potential as a reverse pathway by which to identify the components of a visual stimulus which are most critical for the creation and retrieval of a visual representation. This review will examine the likelihood that the information represented in visual mental imagery reflects distinctive object features thought to facilitate efficient object categorization and recognition during perceptual viewing. If it is the case that these representational features resemble their sensory counterparts in both spatial and semantic qualities, they may well be accessible through mental imagery as evaluated through current investigative techniques. In this review, methods applied to mental imagery research and their findings are reviewed and evaluated for their efficiency in accessing internal representations, and implications for identifying diagnostic features are discussed. An argument is made for the benefits of combining mental imagery assessment methods with diagnostic feature research to advance the understanding of visual perceptive processes, with suggestions for avenues of future investigation. PMID:28588538
Hopkins during SODI-DCMIX 2 Experiment
2013-11-30
ISS038-E-009255 (26 Nov. 2013) --- In the International Space Station?s Destiny laboratory, NASA astronaut Michael Hopkins, Expedition 38 flight engineer, prepares to install and activate the Selectable Optics Diagnostic Instrument (SODI) cell array two in the Microgravity Science Glovebox (MSG) for the Selectable Optics Diagnostic Instrument-Diffusion Coefficient in Mixtures 2 (SODI-DCMIX 2) experiment. SODI-DCMIX 2 is supporting research to determine diffusion coefficients in different petroleum field samples and refine petroleum reservoir models to help lead to more efficient extraction of oil resources.
Hopkins during SODI-DCMIX 2 Experiment
2013-11-30
ISS038-E-009253 (26 Nov. 2013) --- In the International Space Station’s Destiny laboratory, NASA astronaut Michael Hopkins, Expedition 38 flight engineer, prepares to install and activate the Selectable Optics Diagnostic Instrument (SODI) cell array two in the Microgravity Science Glovebox (MSG) for the Selectable Optics Diagnostic Instrument-Diffusion Coefficient in Mixtures 2 (SODI-DCMIX 2) experiment. SODI-DCMIX 2 is supporting research to determine diffusion coefficients in different petroleum field samples and refine petroleum reservoir models to help lead to more efficient extraction of oil resources.
Gharibyan, N.; Shaughnessy, D. A.; Moody, K. J.; ...
2016-08-05
The solid debris collection capability at the National Ignition Facility has been expanded to include a third line-of-sight assembly. The solid radiochemistry nuclear diagnostic measurement of the ratio of gold isotopes is dependent on the efficient collection of neutron-activated hohlraum debris by passive metal disks. As a result, the collection of target debris at this new location is more reliable in comparison to the historic locations, and it appears to be independent of collector surface ablation.
An Efficient Reachability Analysis Algorithm
NASA Technical Reports Server (NTRS)
Vatan, Farrokh; Fijany, Amir
2008-01-01
A document discusses a new algorithm for generating higher-order dependencies for diagnostic and sensor placement analysis when a system is described with a causal modeling framework. This innovation will be used in diagnostic and sensor optimization and analysis tools. Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in-situ platforms. This algorithm will serve as a power tool for technologies that satisfy a key requirement of autonomous spacecraft, including science instruments and in-situ missions.
Gharibyan, N; Shaughnessy, D A; Moody, K J; Grant, P M; Despotopulos, J D; Faye, S A; Jedlovec, D R; Yeamans, C B
2016-11-01
The solid debris collection capability at the National Ignition Facility has been expanded to include a third line-of-sight assembly. The solid radiochemistry nuclear diagnostic measurement of the ratio of gold isotopes is dependent on the efficient collection of neutron-activated hohlraum debris by passive metal disks. The collection of target debris at this new location is more reliable in comparison to the historic locations, and it appears to be independent of collector surface ablation.
Bowen, Jason D; Huang, Qiu; Ellin, Justin R; Lee, Tzu-Cheng; Shrestha, Uttam; Gullberg, Grant T; Seo, Youngho
2013-10-21
Single photon emission computed tomography (SPECT) myocardial perfusion imaging remains a critical tool in the diagnosis of coronary artery disease. However, after more than three decades of use, photon detection efficiency remains poor and unchanged. This is due to the continued reliance on parallel-hole collimators first introduced in 1964. These collimators possess poor geometric efficiency. Here we present the performance evaluation results of a newly designed multipinhole collimator with 20 pinhole apertures (PH20) for commercial SPECT systems. Computer simulations and numerical observer studies were used to assess the noise, bias and diagnostic imaging performance of a PH20 collimator in comparison with those of a low energy high resolution (LEHR) parallel-hole collimator. Ray-driven projector/backprojector pairs were used to model SPECT imaging acquisitions, including simulation of noiseless projection data and performing MLEM/OSEM image reconstructions. Poisson noise was added to noiseless projections for realistic projection data. Noise and bias performance were investigated for five mathematical cardiac and torso (MCAT) phantom anatomies imaged at two gantry orbit positions (19.5 and 25.0 cm). PH20 and LEHR images were reconstructed with 300 MLEM iterations and 30 OSEM iterations (ten subsets), respectively. Diagnostic imaging performance was assessed by a receiver operating characteristic (ROC) analysis performed on a single MCAT phantom; however, in this case PH20 images were reconstructed with 75 pixel-based OSEM iterations (four subsets). Four PH20 projection views from two positions of a dual-head camera acquisition and 60 LEHR projections were simulated for all studies. At uniformly-imposed resolution of 12.5 mm, significant improvements in SNR and diagnostic sensitivity (represented by the area under the ROC curve, or AUC) were realized when PH20 collimators are substituted for LEHR parallel-hole collimators. SNR improves by factors of 1.94-2.34 for the five patient anatomies and two orbital positions studied. For the ROC analysis the PH20 AUC is larger than the LEHR AUC with a p-value of 0.0067. Bias performance, however, decreases with the use of PH20 collimators. Systematic analyses showed PH20 collimators present improved diagnostic imaging performance over LEHR collimators, requiring only collimator exchange on existing SPECT cameras for their use.
NASA Astrophysics Data System (ADS)
Bowen, Jason D.; Huang, Qiu; Ellin, Justin R.; Lee, Tzu-Cheng; Shrestha, Uttam; Gullberg, Grant T.; Seo, Youngho
2013-10-01
Single photon emission computed tomography (SPECT) myocardial perfusion imaging remains a critical tool in the diagnosis of coronary artery disease. However, after more than three decades of use, photon detection efficiency remains poor and unchanged. This is due to the continued reliance on parallel-hole collimators first introduced in 1964. These collimators possess poor geometric efficiency. Here we present the performance evaluation results of a newly designed multipinhole collimator with 20 pinhole apertures (PH20) for commercial SPECT systems. Computer simulations and numerical observer studies were used to assess the noise, bias and diagnostic imaging performance of a PH20 collimator in comparison with those of a low energy high resolution (LEHR) parallel-hole collimator. Ray-driven projector/backprojector pairs were used to model SPECT imaging acquisitions, including simulation of noiseless projection data and performing MLEM/OSEM image reconstructions. Poisson noise was added to noiseless projections for realistic projection data. Noise and bias performance were investigated for five mathematical cardiac and torso (MCAT) phantom anatomies imaged at two gantry orbit positions (19.5 and 25.0 cm). PH20 and LEHR images were reconstructed with 300 MLEM iterations and 30 OSEM iterations (ten subsets), respectively. Diagnostic imaging performance was assessed by a receiver operating characteristic (ROC) analysis performed on a single MCAT phantom; however, in this case PH20 images were reconstructed with 75 pixel-based OSEM iterations (four subsets). Four PH20 projection views from two positions of a dual-head camera acquisition and 60 LEHR projections were simulated for all studies. At uniformly-imposed resolution of 12.5 mm, significant improvements in SNR and diagnostic sensitivity (represented by the area under the ROC curve, or AUC) were realized when PH20 collimators are substituted for LEHR parallel-hole collimators. SNR improves by factors of 1.94-2.34 for the five patient anatomies and two orbital positions studied. For the ROC analysis the PH20 AUC is larger than the LEHR AUC with a p-value of 0.0067. Bias performance, however, decreases with the use of PH20 collimators. Systematic analyses showed PH20 collimators present improved diagnostic imaging performance over LEHR collimators, requiring only collimator exchange on existing SPECT cameras for their use.
Paper-based archiving of biological samples from fish for detecting betanodavirus.
Navaneeth Krishnan, A; Bhuvaneswari, T; Ezhil Praveena, P; Jithendran, K P
2016-07-01
This study was carried out to evaluate the efficiency of the Flinders Technology Associates (FTA(®)) card (Whatman(®)) as a sampling device and storage platform for RNA from betanodavirus-infected biological samples (viz., larvae, broodstock, cell culture supernatants and rearing seawater spiked with infected materials). The study showed that FTA cards can be used to detect betanodaviruses by reverse transcription-polymerase chain reaction (RT-PCR). The diagnostic efficiency of RT-PCR from all sample types on FTA cards decreased after 21 days of storage at 4 °C, although the virus could be detected up to 28 days by nested RT-PCR. The FTA card protocol thus provides a supplementary method for quick and easy collection of samples, preservation of RNA on a dry storage basis, and detection of betanodavirus-infected fish.
Impact of Coronary Calcification on Clinical Management in Patients With Acute Chest Pain
Bittner, Daniel O.; Mayrhofer, Thomas; Bamberg, Fabian; Hallett, Travis R.; Janjua, Sumbal; Addison, Daniel; Nagurney, John T.; Udelson, James E.; Lu, Michael T.; Truong, Quynh A.; Woodard, Pamela K.; Hollander, Judd E.; Miller, Chadwick; Chang, Anna Marie; Singh, Harjit; Litt, Harold; Hoffmann, Udo; Ferencik, Maros
2018-01-01
Background Coronary artery calcification (CAC) may impair diagnostic assessment of coronary computed tomography angiography (CTA). We determined whether CAC affects efficiency of coronary CTA in patients with suspected acute coronary syndrome (ACS). Methods and Results This is a pooled analysis of ACRIN-PA-4005 and ROMICAT-II trial comparing an initial coronary CTA strategy to standard of care in acute chest pain patients. In the CTA arms, we investigated appropriateness of downstream testing, cost and diagnostic yield to identify patients with obstructive coronary artery disease (CAD) on subsequent invasive coronary angiography (ICA) across CAC score strata (Agatston score: 0, >0–10, >10–100, >100–400, >400). Out of 1,234 patients (mean age 51±8.8 years), 80 (6.5%) had obstructive CAD (≥70% stenosis), and 68 (5.5%) had ACS. Prevalence of obstructive CAD (1% to 64%), ACS (1% to 44%), downstream testing (4% to 72%), total (2337 US$ to 8484 US$) and diagnostic cost (2310 US$ to 6678 US$) increased across CAC strata (p<0.001). As the increase in testing and cost were lower than the increase of ACS rate in patients with CAC>400, cost to diagnose one ACS was lowest in this group (19,283 US$ vs. 464,399 US$) as compared to patients without CAC. The diagnostic yield of ICA was highest in patients with CAC>400 (87% vs. 38%). Conclusion Downstream testing, total and diagnostic cost increased with increasing CAC, but were found to be appropriate, as obstructive CAD and ACS were more prevalent in patients with high CAC. In patients with acute chest pain undergoing coronary CTA, cost efficient testing and excellent diagnostic yield can be achieved even with high CAC burden. Clinical Trial Registration Information URL: https://clinicaltrials.gov. Unique identifier: NCT01084239 and NCT00933400. PMID:28487318
Management of early renal anaemia: diagnostic work-up, iron therapy, epoetin therapy.
Van Wyck, D B
2000-01-01
Effective management of early anaemia in the course of chronic renal insufficiency requires the following: (i) implementing an efficient diagnostic strategy to exclude common contributing factors; (ii) initiating epoetin therapy for the majority of patients; for and (iii) ensuring adequate iron supply erythropoiesis. Diagnostic inquiry is warranted whenever the haemoglobin concentration is below the normal range adjusted for age and gender. The most efficient diagnostic approach is to assume erythropoietin deficiency, exclude iron deficiency, and pursue further diagnostic tests only when red-cell indices are abnormal or when leukopenia or thrombocytopenia are also present. Macrocytosis should prompt an inquiry into alcoholism, B12 deficiency, or folate deficiency. Microcytosis suggests iron deficiency or thalassaemia. Associated cytopenias raise the possibility of alcohol toxicity, pernicious anaemia, malignancy, or myelodysplastic syndrome. Epoetin therapy is warranted whenever the haemoglobin concentration has fallen below 10.0 g/dl. To initiate therapy prior to dialysis, epoetin should be administered at an average dose of 100 IU/kg/week (80-120 IU/kg/week, 50-150 IU/kg/ week) by subcutaneous injection. Haemoglobin concentration should be monitored every 2 weeks and the epoetin dose adjusted by increments or decrements of 25% to maintain a rate of rise of haemoglobin concentration of 0.2-0.6 g/dl (0.3 0.6 g/dl/week, 0.2-0.5 g/dl/week). When the target range is achieved, the dose of epoetin should be continually adjusted to maintain a stable haemoglobin concentration. Transferrin saturation and ferritin concentration should be monitored monthly, and sufficient iron provided to maintain transferrin saturation above 20%. The lower the haemoglobin concentration, the greater the likelihood that future intravenous iron will be required. Oral iron supplements should be avoided, since they are costly, ineffective, and troublesome to patients. Finally, a blunted therapeutic response to epoetin therapy provides important diagnostic information and gnostic inquiry.
Abdul-Razak, Suraya; Rahmat, Radzi; Mohd Kasim, Alicezah; Rahman, Thuhairah Abdul; Muid, Suhaila; Nasir, Nadzimah Mohd; Ibrahim, Zubin; Kasim, Sazzli; Ismail, Zaliha; Abdul Ghani, Rohana; Sanusi, Abdul Rais; Rosman, Azhari; Nawawi, Hapizah
2017-10-16
Familial hypercholesterolaemia (FH) is a genetic disorder with a high risk of developing premature coronary artery disease that should be diagnosed as early as possible. Several clinical diagnostic criteria for FH are available, with the Dutch Lipid Clinic Criteria (DLCC) being widely used. Information regarding diagnostic performances of the other criteria against the DLCC is scarce. We aimed to examine the diagnostic performance of the Simon-Broom (SB) Register criteria, the US Make Early Diagnosis to Prevent Early Deaths (US MEDPED) and the Japanese FH Management Criteria (JFHMC) compared to the DLCC. Seven hundered fifty five individuals from specialist clinics and community health screenings with LDL-c level ≥ 4.0 mmol/L were selected and diagnosed as FH using the DLCC, the SB Register criteria, the US MEDPED and the JFHMC. The sensitivity, specificity, efficiency, positive and negative predictive values of individuals screened with the SB register criteria, US MEDPED and JFHMC were assessed against the DLCC. We found the SB register criteria identified more individuals with FH compared to the US MEDPED and the JFHMC (212 vs. 105 vs. 195; p < 0.001) when assessed against the DLCC. The SB Register criteria, the US MEDPED and the JFHMC had low sensitivity (51.1% vs. 25.3% vs. 47.0% respectively). The SB Register criteria showed better diagnostic performance than the other criteria with 98.8% specificity, 28.6% efficiency value, 98.1% and 62.3% for positive and negative predictive values respectively. The SB Register criteria appears to be more useful in identifying positive cases leading to genetic testing compared to the JFHMC and US MEDPED in this Asian population. However, further research looking into a suitable diagnosis criterion with high likelihood of positive genetic findings is required in the Asian population including in Malaysia.
Wang, An; Fan, Jie; Chen, Xiaofeng; Wang, Shaohua
2018-03-01
The existence of two diagnostic systems, the Boston and Japan criteria, for immunoglobulin G4-related disease (IgG4-RD) confuse the medical practice. We aimed to develop a comprehensive assessment based on the weight of each diagnostic item in the existing criteria to improve the diagnostic efficiency of Boston criteria. We assessed the patients enrolled by a systematic review of the literatures using the Boston criteria, Japan criteria and a tentative comprehensive assessment respectively, and evaluated the efficiency of each system and their consistency. Our analysis showed that the distinction in pathological diagnostic items was similar for the Boston criteria (IgG4+/IgG+ ratio, P<0.01; the number of pathological features and IgG4+ count, P<0.001) and comprehensive assessment (IgG4+/IgG+ ratio and the number of pathological features, P<0.001; IgG4+ count, P<0.05). For the Japan criteria, a good distinction in the number of pathological features was demonstrated (P<0.05) but the difference in the IgG4+/IgG+ ratio and IgG4+ count was not significant. There was relatively poor consistency between the Boston and Japan criteria (Kappa =0.482, P<0.001), while there was good agreement (Kappa =0.811, P<0.001), but a significant difference (P=0.011, McNemar matching test), between the Boston criteria and comprehensive assessment. The current two diagnostic systems have poor consistency. Comprehensive assessment has good agreement with the Boston criteria, but can identify those cases in Boston Category 3 who could still be diagnosed as IgG4-related lung disease. Considering the weight of diagnostic items, the scoring system is a tentative exploration that should be improved with further experience in diagnosing IgG4-related lung disease.
Rendeiro, Daniel G.; Deyle, Gail D.; Boissonnault, William G.
2015-01-01
Background: Physical therapy care for musculoskeletal conditions includes an ongoing process that systematically considers and prioritises diagnostic hypotheses. These diagnostic hypotheses include those that are typical for common musculoskeletal conditions, and must also include more rare conditions that would require care outside the scope of practice of the physical therapist. When additional screening is required, physical therapists collaborate with other providers or directly order the appropriate tests to rule out suspected pathology. Case Description: This article illustrates the use of musculoskeletal imaging ordered by a physical therapist to guide ongoing management of a patient with back pain and a history of cancer. Outcomes: The patient successfully returned to moderate-intensity sport activities after a course of physical therapy. Discussion: This case provides an example of how clinical diagnostic reasoning combined with clinical privileges to order musculoskeletal imaging can facilitate diagnostic accuracy in a timely and cost-efficient manner. PMID:26309382
NASA Astrophysics Data System (ADS)
Ushenko, Yu. A.; Prysyazhnyuk, V. P.; Gavrylyak, M. S.; Gorsky, M. P.; Bachinskiy, V. T.; Vanchuliak, O. Ya.
2015-02-01
A new information optical technique of diagnostics of the structure of polycrystalline films of blood plasma is proposed. The model of Mueller-matrix description of mechanisms of optical anisotropy of such objects as optical activity, birefringence, as well as linear and circular dichroism is suggested. The ensemble of informationally topical azimuthally stable Mueller-matrix invariants is determined. Within the statistical analysis of such parameters distributions the objective criteria of differentiation of films of blood plasma taken from healthy and patients with liver cirrhosis were determined. From the point of view of probative medicine the operational characteristics (sensitivity, specificity and accuracy) of the information-optical method of Mueller-matrix mapping of polycrystalline films of blood plasma were found and its efficiency in diagnostics of liver cirrhosis was demonstrated. Prospects of application of the method in experimental medicine to differentiate postmortem changes of the myocardial tissue was examined.
Smoldovskaya, Olga; Feyzkhanova, Guzel; Arefieva, Alla; Voloshin, Sergei; Ivashkina, Olga; Reznikov, Yuriy; Rubina, Alla
2016-01-01
Immunological test systems for diagnostics of type I hypersensitivity involve the following types of antigens: whole allergen extracts, individual highly purified proteins and their recombinant analogues. The goal of this study was to compare the results obtained with whole allergen extracts (birch pollen, cat dander, and timothy grass pollen) and their respective recombinant proteins in biochip-based immunoassay. Multiplex fluorescent immunoassay of 139 patients' blood serum samples was carried out using biological microchips (biochips). sIgE concentrations for the chosen allergens and their recombinant components were measured. ROC analysis was used for comparison of the results and determination of diagnostic accuracy. The results for the birch pollen extract and its recombinant allergens have shown that the diagnostic accuracy of the methods utilizing the whole allergen extract, its major component Bet v 1 and the combination of major and minor components (Bet v 1 and Bet v 2) was the same. Values for diagnostic accuracy for the cat dander extract and its major recombinant component Fel d 1 were equal. In contrast with birch pollen and cat dander allergens, using of recombinant components of timothy grass pollen (Phl p 1, Phl p 5, Phl p 7 and Phl p 12) did not allow reaching the diagnostic accuracy of using natural extract. Multiplex analysis of samples obtained from patients with allergy to birch pollen and cat dander using biological microchips has shown that comparable accuracy was observed for the assay with natural extracts and recombinant allergens. In the case of timothy grass allergen, using the recombinant components may be insufficient.
Nuñez-Garcia, Javier; Downs, Sara H; Parry, Jessica E; Abernethy, Darrell A; Broughan, Jennifer M; Cameron, Angus R; Cook, Alasdair J; de la Rua-Domenech, Ricardo; Goodchild, Anthony V; Gunn, Jane; More, Simon J; Rhodes, Shelley; Rolfe, Simon; Sharp, Michael; Upton, Paul A; Vordermeier, H Martin; Watson, Eamon; Welsh, Michael; Whelan, Adam O; Woolliams, John A; Clifton-Hadley, Richard S; Greiner, Matthias
2018-05-01
Bovine Tuberculosis (bTB) in cattle is a global health problem and eradication of the disease requires accurate estimates of diagnostic test performance to optimize their efficiency. The objective of this study was, through statistical meta-analyses, to obtain estimates of sensitivity (Se) and specificity (Sp), for 14 different ante-mortem and post-mortem diagnostic tests for bTB in cattle. Using data from a systematic review of the scientific literature (published 1934-2009) diagnostic Se and Sp were estimated using Bayesian logistic regression models adjusting for confounding factors. Random effect terms were used to account for unexplained heterogeneity. Parameters in the models were implemented using Markov Chain Monte Carlo (MCMC), and posterior distributions for the diagnostic parameters with adjustment for covariates (confounding factors) were obtained using the inverse logit function. Estimates for Se and/or Sp of the tuberculin skin tests and the IFN-γ blood test were compared with estimates published 2010-2015. Median Se for the single intradermal comparative cervical tuberculin skin (SICCT) test (standard interpretation) was 0.50 and Bayesian credible intervals (CrI) were wide (95% CrI 0.26, 0.78). Median Sp for the SICCT test was 1.00 (95% CrI 0.99, 1.00). Estimates for the IFN-γ blood test Bovine Purified Protein Derivative (PPD)-Avian PPD and Early Secreted Antigen target 6 and Culture Filtrate Protein 10 (ESAT-6/CFP10) ESAT6/CFP10 were 0.67 (95% CrI 0.49, 0.82) and 0.78 (95% CrI 0.60, 0.90) respectively for Se, and 0.98 (95% CrI 0.96, 0.99) and 0.99 (95% CrI 0.99, 1.00) for Sp. The study provides an overview of the accuracy of a range of contemporary diagnostic tests for bTB in cattle. Better understanding of diagnostic test performance is essential for the design of effective control strategies and their evaluation. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Blood culture-negative endocarditis: Improving the diagnostic yield using new diagnostic tools.
Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier
2017-11-01
Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients.In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France.A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38.By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods, but also agents requiring specific management such as Mycoplasma hominis and Tropheryma whipplei. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.
GapMap: Enabling Comprehensive Autism Resource Epidemiology
Albert, Nikhila; Schwartz, Jessey; Du, Michael
2017-01-01
Background For individuals with autism spectrum disorder (ASD), finding resources can be a lengthy and difficult process. The difficulty in obtaining global, fine-grained autism epidemiological data hinders researchers from quickly and efficiently studying large-scale correlations among ASD, environmental factors, and geographical and cultural factors. Objective The objective of this study was to define resource load and resource availability for families affected by autism and subsequently create a platform to enable a more accurate representation of prevalence rates and resource epidemiology. Methods We created a mobile application, GapMap, to collect locational, diagnostic, and resource use information from individuals with autism to compute accurate prevalence rates and better understand autism resource epidemiology. GapMap is hosted on AWS S3, running on a React and Redux front-end framework. The backend framework is comprised of an AWS API Gateway and Lambda Function setup, with secure and scalable end points for retrieving prevalence and resource data, and for submitting participant data. Measures of autism resource scarcity, including resource load, resource availability, and resource gaps were defined and preliminarily computed using simulated or scraped data. Results The average distance from an individual in the United States to the nearest diagnostic center is approximately 182 km (50 miles), with a standard deviation of 235 km (146 miles). The average distance from an individual with ASD to the nearest diagnostic center, however, is only 32 km (20 miles), suggesting that individuals who live closer to diagnostic services are more likely to be diagnosed. Conclusions This study confirmed that individuals closer to diagnostic services are more likely to be diagnosed and proposes GapMap, a means to measure and enable the alleviation of increasingly overburdened diagnostic centers and resource-poor areas where parents are unable to diagnose their children as quickly and easily as needed. GapMap will collect information that will provide more accurate data for computing resource loads and availability, uncovering the impact of resource epidemiology on age and likelihood of diagnosis, and gathering localized autism prevalence rates. PMID:28473303
GapMap: Enabling Comprehensive Autism Resource Epidemiology.
Albert, Nikhila; Daniels, Jena; Schwartz, Jessey; Du, Michael; Wall, Dennis P
2017-05-04
For individuals with autism spectrum disorder (ASD), finding resources can be a lengthy and difficult process. The difficulty in obtaining global, fine-grained autism epidemiological data hinders researchers from quickly and efficiently studying large-scale correlations among ASD, environmental factors, and geographical and cultural factors. The objective of this study was to define resource load and resource availability for families affected by autism and subsequently create a platform to enable a more accurate representation of prevalence rates and resource epidemiology. We created a mobile application, GapMap, to collect locational, diagnostic, and resource use information from individuals with autism to compute accurate prevalence rates and better understand autism resource epidemiology. GapMap is hosted on AWS S3, running on a React and Redux front-end framework. The backend framework is comprised of an AWS API Gateway and Lambda Function setup, with secure and scalable end points for retrieving prevalence and resource data, and for submitting participant data. Measures of autism resource scarcity, including resource load, resource availability, and resource gaps were defined and preliminarily computed using simulated or scraped data. The average distance from an individual in the United States to the nearest diagnostic center is approximately 182 km (50 miles), with a standard deviation of 235 km (146 miles). The average distance from an individual with ASD to the nearest diagnostic center, however, is only 32 km (20 miles), suggesting that individuals who live closer to diagnostic services are more likely to be diagnosed. This study confirmed that individuals closer to diagnostic services are more likely to be diagnosed and proposes GapMap, a means to measure and enable the alleviation of increasingly overburdened diagnostic centers and resource-poor areas where parents are unable to diagnose their children as quickly and easily as needed. GapMap will collect information that will provide more accurate data for computing resource loads and availability, uncovering the impact of resource epidemiology on age and likelihood of diagnosis, and gathering localized autism prevalence rates. ©Nikhila Albert, Jena Daniels, Jessey Schwartz, Michael Du, Dennis P Wall. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 04.05.2017.
Active Surveillance of Prostate Cancer: Use, Outcomes, Imaging, and Diagnostic Tools
Tosoian, Jeffrey J; Loeb, Stacy; Epstein, Jonathan I; Turkbey, Baris; Choyke, Peter; Schaeffer, Edward M
2016-01-01
Active surveillance (AS) has emerged as a standard management option for men with very low-risk and low-risk prostate cancer, and contemporary data indicate that use of AS is increasing in the United States and abroad. In the favorable-risk population, reports from multiple prospective cohorts indicate a less than 1% likelihood of metastatic disease and prostate cancer-specific mortality over intermediate-term follow-up (median 5 to 6 years). Higher-risk men participating in AS appear to be at increased risk of adverse outcomes, but these populations have not been adequately studied to this point. Although monitoring on AS largely relies on serial prostate biopsy, a procedure associated with significant morbidity, there is a need for improved diagnostic tools for patient selection and monitoring. Revisions from the 2014 International Society of Urologic Pathology consensus conference have yielded a more intuitive reporting system and detailed reporting of low-intermediate grade tumors, which should facilitate the practice of AS. Meanwhile, emerging modalities such as multiparametric magnetic resonance imaging and tissue-based molecular testing have shown prognostic value in some populations. At this time, however, these instruments have not been sufficiently studied to consider their routine, standardized use in the AS setting. Future studies should seek to identify those platforms most informative in the AS population and propose a strategy by which promising diagnostic tools can be safely and efficiently incorporated into clinical practice. PMID:27249729
Schieffelin, John; Moses, Lina M; Shaffer, Jeffrey; Goba, Augustine; Grant, Donald S
2015-01-01
The current Ebola outbreak in West Africa has affected more people than all previous outbreaks combined. The current diagnostic method of choice, quantitative polymerase chain reaction, requires specialized conditions as well as specially trained technicians. Insufficient testing capacity has extended the time from sample collection to results. These delays have led to further delays in the transfer and treatment to Ebola Treatment Units. A sensitive and specific point-of-care device that could be used reliably in low resource settings by healthcare workers with minimal training would increase the efficiency of triage and appropriate transfer of care. This article describes a study designed to validate the sensitivity and specificity of the ReEBOVTM RDT using venous whole blood and capillary blood obtained via fingerprick. We present the scientific and clinical rationale for the decisions made in the design of a diagnostic validation study to be conducted in an outbreak setting. The multi-site strategy greatly complicated implementation. In addition, a decrease in cases in one geographic area along with a concomitant increase in other areas made site selection challenging. Initiation of clinical trials during rapidly evolving outbreaks requires significant cooperation on a national level between research teams implementing studies and clinical care providers. Coordination and streamlining of approval process is essential if trials are to be implemented in a timely fashion. PMID:26768566
2015-08-18
of Defense (DoD) to achieve cost-effective energy efficiency at much greater scale than other commercially available techniques of measuring energy...recommends specific energy conservation measures (ECMs), and quantifies significant potential return on investment. ERDC/CERL TR-15-18 iii...effective energy efficiency at much greater scale than other commercially available techniques of measuring energy loss due to envelope inefficien- cies
[Comparative diagnostic value of Helicobacter pylori infection testing methods].
Girdalidze, A M; Elisabedashvili, G V; Sharvadze, L G; Dzhorbenadze, T A
2013-12-01
In 213 patients with gastric and duodenal pathology, including received surgery, comparative estimation of results of Helicobacter pylori (Hp) infection testing with invasive and noninvasive methods, were performed. Material for invasive endoscopic biopsy test (EBT), including rapid urease test (RUT) for rapid Hp identification by determination of urease activity, smear cytology and histology was extracted on endoscopy or intraoperationally. RUT was carried out with the help of URE-HP test kit. Serological test for Hp antibodies IgG and IgA class was performed by IFA using kit ELISA. 13С urea breath test (UBT) was made by determination of 13/12CO2 in breath samples on infrared spectroscope. Based on 5 different methods of Hp infection testing Hp positivity in 172 (80,8%) and Hp negativity in 41 (19,2%) from 213 examined patients was revealed. 13С-UBT revealed the highest diagnostic value (accuracy-97,5%, sensibility-97,0%, specificity-100%) in Hp infection diagnostics. In treatment efficiency control this parameters of 13С-UBT are also much high (96,7%, 90,0% and 100% respectively). In spite of high sensitivity of serological test (100%), it had comparative low specificity (71,0%) with high probability of false positive results in treated patients (antibodies titer to Hp after eradication retains for a long time). Thought, this test may be successfully used only in primary patients and in epidemiological studies. Among three methods of EBT, Hp infection detection with RUT revealed the best results (accuracy-94,8%, sensibility-95,0%, specificity-100%). Correlation of RUT and UBT results and much higher diagnostic value of UBT, necessitate RUT with histological study of stomach body mucosa to perform in patients over 45 year, with prolonged anamnesis and dangerous symptoms of disease. In Hp positive patients correlation of index DOB‰ of breath test with results of RUT was revealed. This can serve the index DOB‰ of 13С-UBT as a marker of Hp infection rate. The (accuracy, sensibility and specificity of breath test with local made 13С-urea (98,7%, 98,5% and 100% respectively) are the same as those for BT with standard 13С-urea (96,7%, 96,2% and 100% respectively). Above mentioned, 13С-UBT advantages (noninvasiveness, simplicity, rapidity, safety) and high diagnostic value exceeding same of other applied tests, give us opportunity to offer 13С-UBT as screening method of Hp infection diagnosis and a method of choise in control of Hp infection treatment efficiency.
[Rationale for a diagnostic approach in non-Graves' orbital inflammation--Report of 61 patients].
Gavard-Perret, A; Lagier, J; Delmas, J; Delas, J; Adenis, J-P; Robert, P-Y
2015-12-01
Orbital inflammatory syndromes include a wide variety of inflammatory intraorbital processes which are very different in terms of clinical presentation and prognosis. We currently prefer to differentiate so-called "specific" inflammations, for which an etiology is able to be identified, from idiopathic orbital inflammatory syndromes (IOIS), for which the etiology remains unknown and the histology is nonspecific. To propose an efficient diagnostic approach for clinicians managing patients with non-Graves' orbital inflammations. This is a retrospective and prospective study concerning 61 patients managed by the medical team for non-Graves' orbital inflammations between May, 1999 and May, 2013 in the ophthalmology departments of Nice and Limoges university hospitals in France. Seventeen specific inflammations, 19 orbital lymphomas and 25 idiopathic orbital inflammatory syndromes were included. Patients were divided into two groups. Thirty-six patients (group 1) underwent primary biopsy, while for the other 25 (group 2), therapy was begun empirically without biopsy. We could therefore compare both approaches in terms of diagnostic efficiency and time until identification of a specific etiology. Our statistical results show that an approach without primary biopsy leads to a number of specific diagnoses statistically much lower than that obtained by the approach with primary biopsy. Also, the risk of missing a specific inflammation (with as a consequence an inappropriate treatment and a risk of functional sequelae as well as a fatal risk of missing a lymphoproliferative pathology) is very clearly higher in the case of not performing primary biopsy. Finally, the average time elapsed between the initial consultation with the ophthalmologist and a specific diagnosis was one month in the case of the first approach, while this delay was almost three times higher with the second approach, with a mean of 2.91 months (P<0.01). Our study shows that biopsy should be the mainstay of diagnostic management. A trial of empiric treatment is only performed first in myositis or in locations where biopsy could jeopardize functional prognosis. It should only be done after biopsy in all other cases. Of course, in all cases of relapse or recurrence after treatment, biopsy should be performed or repeated. The diagnostic work-up of a patient with an orbital inflammatory process must of course include blood testing and orbital imaging, but also a systematic primary biopsy for histological examination in the vast majority of cases. It must be repeated at least in the case of any doubt about the diagnosis or in the case of any recurrence or resistance to treatment. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Bone, Daniel; Bishop, Somer; Black, Matthew P.; Goodwin, Matthew S.; Lord, Catherine; Narayanan, Shrikanth S.
2016-01-01
Background Machine learning (ML) provides novel opportunities for human behavior research and clinical translation, yet its application can have noted pitfalls (Bone et al., 2015). In this work, we fastidiously utilize ML to derive autism spectrum disorder (ASD) instrument algorithms in an attempt to improve upon widely-used ASD screening and diagnostic tools. Methods The data consisted of Autism Diagnostic Interview-Revised (ADI-R) and Social Responsiveness Scale (SRS) scores for 1,264 verbal individuals with ASD and 462 verbal individuals with non-ASD developmental or psychiatric disorders (DD), split at age 10. Algorithms were created via a robust ML classifier, support vector machine (SVM), while targeting best-estimate clinical diagnosis of ASD vs. non-ASD. Parameter settings were tuned in multiple levels of cross-validation. Results The created algorithms were more effective (higher performing) than current algorithms, were tunable (sensitivity and specificity can be differentially weighted), and were more efficient (achieving near-peak performance with five or fewer codes). Results from ML-based fusion of ADI-R and SRS are reported. We present a screener algorithm for below (above) age 10 that reached 89.2% (86.7%) sensitivity and 59.0% (53.4%) specificity with only five behavioral codes. Conclusions ML is useful for creating robust, customizable instrument algorithms. In a unique dataset comprised of controls with other difficulties, our findings highlight limitations of current caregiver-report instruments and indicate possible avenues for improving ASD screening and diagnostic tools. PMID:27090613
Bone, Daniel; Bishop, Somer L; Black, Matthew P; Goodwin, Matthew S; Lord, Catherine; Narayanan, Shrikanth S
2016-08-01
Machine learning (ML) provides novel opportunities for human behavior research and clinical translation, yet its application can have noted pitfalls (Bone et al., 2015). In this work, we fastidiously utilize ML to derive autism spectrum disorder (ASD) instrument algorithms in an attempt to improve upon widely used ASD screening and diagnostic tools. The data consisted of Autism Diagnostic Interview-Revised (ADI-R) and Social Responsiveness Scale (SRS) scores for 1,264 verbal individuals with ASD and 462 verbal individuals with non-ASD developmental or psychiatric disorders, split at age 10. Algorithms were created via a robust ML classifier, support vector machine, while targeting best-estimate clinical diagnosis of ASD versus non-ASD. Parameter settings were tuned in multiple levels of cross-validation. The created algorithms were more effective (higher performing) than the current algorithms, were tunable (sensitivity and specificity can be differentially weighted), and were more efficient (achieving near-peak performance with five or fewer codes). Results from ML-based fusion of ADI-R and SRS are reported. We present a screener algorithm for below (above) age 10 that reached 89.2% (86.7%) sensitivity and 59.0% (53.4%) specificity with only five behavioral codes. ML is useful for creating robust, customizable instrument algorithms. In a unique dataset comprised of controls with other difficulties, our findings highlight the limitations of current caregiver-report instruments and indicate possible avenues for improving ASD screening and diagnostic tools. © 2016 Association for Child and Adolescent Mental Health.
Diagnosing schistosomiasis: where are we?
Gomes, Luciana Inácia; Enk, Martin Johannes; Rabello, Ana
2014-01-01
In light of the World Health Organization's initiative to extend schistosomiasis morbidity and mortality control programs by including a disease elimination strategy in low endemic settings, this paper reviews diagnostic tools described during the last decades and provide an overview of ongoing efforts in making an efficient diagnostic tool available worldwide. A literature search on PubMed using the search criteria schistosomiasis and diagnosis within the period from 1978 to 2013 was carried out. Articles with abstract in English and that used laboratory techniques specifically developed for the detection of schistosomiasis in humans were included. Publications were categorized according to the methodology applied (parasitological, immunological, or molecular) and stage of development (in house development, limited field, or large scale field testing). The initial research generated 4,535 publications, of which only 643 met the inclusion criteria. The vast majority (537) of the publications focused on immunological techniques; 81 focused on parasitological diagnosis, and 25 focused on molecular diagnostic methods. Regarding the stage of development, 307 papers referred to in-house development, 202 referred to limited field tests, and 134 referred to large scale field testing. The data obtained show that promising new diagnostic tools, especially for Schistosoma antigen and deoxyribonucleic acid (DNA) detection, which are characterized by high sensitivity and specificity, are being developed. In combination with international funding initiatives these tools may result in a significant step forward in successful disease elimination and surveillance, which is to make efficient tests accessible and its large use self-sustainable for control programs in endemic countries.
Downing, Harriet; Thomas-Jones, Emma; Gal, Micaela; Waldron, Cherry-Ann; Sterne, Jonathan; Hollingworth, William; Hood, Kerenza; Delaney, Brendan; Little, Paul; Howe, Robin; Wootton, Mandy; Macgowan, Alastair; Butler, Christopher C; Hay, Alastair D
2012-07-19
Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted.The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens.We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children.
2012-01-01
Background Urinary tract infection (UTI) is common in children, and may cause serious illness and recurrent symptoms. However, obtaining a urine sample from young children in primary care is challenging and not feasible for large numbers. Evidence regarding the predictive value of symptoms, signs and urinalysis for UTI in young children is urgently needed to help primary care clinicians better identify children who should be investigated for UTI. This paper describes the protocol for the Diagnosis of Urinary Tract infection in Young children (DUTY) study. The overall study aim is to derive and validate a cost-effective clinical algorithm for the diagnosis of UTI in children presenting to primary care acutely unwell. Methods/design DUTY is a multicentre, diagnostic and prospective observational study aiming to recruit at least 7,000 children aged before their fifth birthday, being assessed in primary care for any acute, non-traumatic, illness of ≤ 28 days duration. Urine samples will be obtained from eligible consented children, and data collected on medical history and presenting symptoms and signs. Urine samples will be dipstick tested in general practice and sent for microbiological analysis. All children with culture positive urines and a random sample of children with urine culture results in other, non-positive categories will be followed up to record symptom duration and healthcare resource use. A diagnostic algorithm will be constructed and validated and an economic evaluation conducted. The primary outcome will be a validated diagnostic algorithm using a reference standard of a pure/predominant growth of at least >103, but usually >105 CFU/mL of one, but no more than two uropathogens. We will use logistic regression to identify the clinical predictors (i.e. demographic, medical history, presenting signs and symptoms and urine dipstick analysis results) most strongly associated with a positive urine culture result. We will then use economic evaluation to compare the cost effectiveness of the candidate prediction rules. Discussion This study will provide novel, clinically important information on the diagnostic features of childhood UTI and the cost effectiveness of a validated prediction rule, to help primary care clinicians improve the efficiency of their diagnostic strategy for UTI in young children. PMID:22812651
New Stethoscope With Extensible Diaphragm.
Takashina, Tsunekazu; Shimizu, Masashi; Muratake, Torakazu; Mayuzumi, Syuichi
2016-08-25
This study compared the diagnostic efficacy of the common suspended diaphragm stethoscope (SDS) with a new extensible diaphragm stethoscope (EDS) for low-frequency heart sounds. The EDS was developed by using an ethylene propylene diene monomer diaphragm. The results showed that the EDS enhanced both the volume and quality of low-frequency heart sounds, and improved the ability of examiners to auscultate such heart sounds. Based on the results of the sound analysis, the EDS is more efficient than the SDS. (Circ J 2016; 80: 2047-2049).
[Staged oncological screening with TG test].
Bakhlaev, I E; Ageenko, A I; Rolik, I S
2006-01-01
The authors present their analysis of screening methods used for early diagnostics of cancer of various localization and for detection of high-risk individuals. They offer a program of step-by-step screening that makes it possible to cover more population with prophylactic examination and to reduce the need for special examination methods. TG-test is a universal and the most informative blastomatous process indicator at any stage, including the preclinical one. The practical screening results double the revealing rate of oncopathology and allow for three-fold reduction in the diagnostic costs compared with standard methods of cancer diagnostics. The medical efficiency of the oncological screening is high; in one third of the examined patients a tumor is diagnosed at the preclinical stage.
Innovation in diagnostic imaging services: assessing the potential for value-based reimbursement.
Garrison, Louis P; Bresnahan, Brian W; Higashi, Mitchell K; Hollingworth, William; Jarvik, Jeffrey G
2011-09-01
Innovation in the field of diagnostic imaging is based primarily on the availability of new and improved equipment that opens the door for new clinical applications. Payments for these imaging procedures are subject to complex Medicare price control schemes, affecting incentives for appropriate use and innovation. Achieving a "dynamically efficient" health care system-one that elicits a socially optimal amount of innovation-requires that innovators be rewarded in relation to the value they add and can demonstrate with evidence. The authors examine how and whether value-based reimbursement for diagnostic imaging services might better reward innovation explicitly for expected improvements in health and economic outcomes. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Motor Fault Diagnosis Based on Short-time Fourier Transform and Convolutional Neural Network
NASA Astrophysics Data System (ADS)
Wang, Li-Hua; Zhao, Xiao-Ping; Wu, Jia-Xin; Xie, Yang-Yang; Zhang, Yong-Hong
2017-11-01
With the rapid development of mechanical equipment, the mechanical health monitoring field has entered the era of big data. However, the method of manual feature extraction has the disadvantages of low efficiency and poor accuracy, when handling big data. In this study, the research object was the asynchronous motor in the drivetrain diagnostics simulator system. The vibration signals of different fault motors were collected. The raw signal was pretreated using short time Fourier transform (STFT) to obtain the corresponding time-frequency map. Then, the feature of the time-frequency map was adaptively extracted by using a convolutional neural network (CNN). The effects of the pretreatment method, and the hyper parameters of network diagnostic accuracy, were investigated experimentally. The experimental results showed that the influence of the preprocessing method is small, and that the batch-size is the main factor affecting accuracy and training efficiency. By investigating feature visualization, it was shown that, in the case of big data, the extracted CNN features can represent complex mapping relationships between signal and health status, and can also overcome the prior knowledge and engineering experience requirement for feature extraction, which is used by traditional diagnosis methods. This paper proposes a new method, based on STFT and CNN, which can complete motor fault diagnosis tasks more intelligently and accurately.
Zongo, Sylvie; Farquet, Valérie; Ridde, Valéry
2016-04-06
Since 2012, rapid diagnostic tests (RDT) for malaria have been in use nationwide in Burkina Faso. The objective is to strengthen health professionals' diagnostic capabilities and promote good therapeutic practices. A qualitative study was conducted to learn about the adoption of this tool in the natural context of a national scale-up policy. This study involved five health centres in two health districts. Twenty-eight individual interviews were conducted in 2013 with health professionals and members of the health district management teams. Health professionals' RDT use and drug prescription practices were observed during 278 curative care consultations over 5 weeks. Health professionals assessed the use of RDT positively as it allowed them to reach clear and accurate diagnoses and above all to deliver appropriate, rational care. However, the introduction of RDTs did not really change their diagnostic practices or prescribing practices for artemisinin-based combination therapy (ACT). They continued to rely predominantly on symptoms in establishing their diagnoses because of doubts regarding the reliability of the tests and the occasional stockouts of RDTs experienced by the health centres. Patients with negative RDT results continued to receive anti-malarial treatments. However, the situation remains quite heterogeneous. The use of RDTs points to the co-existence of official standards and different standards applied in practice. Setting up regular supervision activities provided an opportunity to observe and understand the various obstacles encountered by health professionals and to monitor how official directives are put into practice. For efficient use of RDTs and their results, health professionals need information and directives that are up-to-date and standardized.
Sakurai, T; Kawamata, R; Kozai, Y; Kaku, Y; Nakamura, K; Saito, M; Wakao, H; Kashima, I
2010-05-01
The aim of the study was to clarify the change in image quality upon X-ray dose reduction and to re-analyse the possibility of X-ray dose reduction in photostimulable phosphor luminescence (PSPL) X-ray imaging systems. In addition, the study attempted to verify the usefulness of multiobjective frequency processing (MFP) and flexible noise control (FNC) for X-ray dose reduction. Three PSPL X-ray imaging systems were used in this study. Modulation transfer function (MTF), noise equivalent number of quanta (NEQ) and detective quantum efficiency (DQE) were evaluated to compare the basic physical performance of each system. Subjective visual evaluation of diagnostic ability for normal anatomical structures was performed. The NEQ, DQE and diagnostic ability were evaluated at base X-ray dose, and 1/3, 1/10 and 1/20 of the base X-ray dose. The MTF of the systems did not differ significantly. The NEQ and DQE did not necessarily depend on the pixel size of the system. The images from all three systems had a higher diagnostic utility compared with conventional film images at the base and 1/3 X-ray doses. The subjective image quality was better at the base X-ray dose than at 1/3 of the base dose in all systems. The MFP and FNC-processed images had a higher diagnostic utility than the images without MFP and FNC. The use of PSPL imaging systems may allow a reduction in the X-ray dose to one-third of that required for conventional film. It is suggested that MFP and FNC are useful for radiation dose reduction.
A dynamic integrated fault diagnosis method for power transformers.
Gao, Wensheng; Bai, Cuifen; Liu, Tong
2015-01-01
In order to diagnose transformer fault efficiently and accurately, a dynamic integrated fault diagnosis method based on Bayesian network is proposed in this paper. First, an integrated fault diagnosis model is established based on the causal relationship among abnormal working conditions, failure modes, and failure symptoms of transformers, aimed at obtaining the most possible failure mode. And then considering the evidence input into the diagnosis model is gradually acquired and the fault diagnosis process in reality is multistep, a dynamic fault diagnosis mechanism is proposed based on the integrated fault diagnosis model. Different from the existing one-step diagnosis mechanism, it includes a multistep evidence-selection process, which gives the most effective diagnostic test to be performed in next step. Therefore, it can reduce unnecessary diagnostic tests and improve the accuracy and efficiency of diagnosis. Finally, the dynamic integrated fault diagnosis method is applied to actual cases, and the validity of this method is verified.
A Dynamic Integrated Fault Diagnosis Method for Power Transformers
Gao, Wensheng; Liu, Tong
2015-01-01
In order to diagnose transformer fault efficiently and accurately, a dynamic integrated fault diagnosis method based on Bayesian network is proposed in this paper. First, an integrated fault diagnosis model is established based on the causal relationship among abnormal working conditions, failure modes, and failure symptoms of transformers, aimed at obtaining the most possible failure mode. And then considering the evidence input into the diagnosis model is gradually acquired and the fault diagnosis process in reality is multistep, a dynamic fault diagnosis mechanism is proposed based on the integrated fault diagnosis model. Different from the existing one-step diagnosis mechanism, it includes a multistep evidence-selection process, which gives the most effective diagnostic test to be performed in next step. Therefore, it can reduce unnecessary diagnostic tests and improve the accuracy and efficiency of diagnosis. Finally, the dynamic integrated fault diagnosis method is applied to actual cases, and the validity of this method is verified. PMID:25685841
Desiere, Frank; Romano Spica, Vincenzo
2012-09-15
This special issue of New Biotechnology is focused on molecular diagnostics and personalised medicine and appears at an epochal moment in the development of the field. The practice of medicine is taking a significant and irrevocable turn towards personalisation, due to the great progress in areas such as genomics, pharmacogenomics and molecular diagnosis. It becomes increasingly apparent that to deliver the promise of personalised treatments, more and more novel medicines discovered today will be presented together with innovative companion diagnostics. The contributions to this volume touch on many disciplines, ranging from cell biology to genetics, immunology, molecular diagnostics, pharmaceutics and economic issues. The contributions of clinicians and basic scientists are synergistically presented to underline better the wide spectrum of studies that can contribute to the new field of personalised medicine. The promising perspectives of individualised treatments are related not only to higher effectiveness, but also to increased efficiency. This is relevant not only for the individual patient, but even more so for the general public, within a wider economical perspective where resources are limited and it becomes more and more mandatory to close the gap between social costs and benefits. This approach follows the steps of a stratified and individualised medicine and finds its final goal in an individualised healthcare. Copyright © 2012 Elsevier B.V. All rights reserved.
Nakazato, Ryo; Slomka, Piotr J.; Fish, Mathews; Schwartz, Ronald G.; Hayes, Sean W.; Thomson, Louise E.J.; Friedman, John D.; Lemley, Mark; Mackin, Maria L.; Peterson, Benjamin; Schwartz, Arielle M.; Doran, Jesse A.; Germano, Guido; Berman, Daniel S.
2014-01-01
Background Obesity is a common source of artifact on conventional SPECT myocardial perfusion imaging (MPI). We evaluated image quality and diagnostic performance of high-efficiency (HE) cadmium-zinc-telluride (CZT) parallel-hole SPECT-MPI for coronary artery disease (CAD) in obese patients. Methods and Results 118 consecutive obese patients at 3 centers (BMI 43.6±8.9 kg/m2, range 35–79.7 kg/m2) had upright/supine HE-SPECT and ICA >6 months (n=67) or low-likelihood of CAD (n=51). Stress quantitative total perfusion deficit (TPD) for upright (U-TPD), supine (S-TPD) and combined acquisitions (C-TPD) was assessed. Image quality (IQ; 5=excellent; <3 nondiagnostic) was compared among BMI 35–39.9 (n=58), 40–44.9 (n=24) and ≥45 (n=36) groups. ROC-curve area for CAD detection (≥50% stenosis) for U-TPD, S-TPD, and C-TPD were 0.80, 0.80, and 0.87, respectively. Sensitivity/specificity was 82%/57% for U-TPD, 74%/71% for S-TPD, and 80%/82% for C-TPD. C-TPD had highest specificity (P=.02). C-TPD normalcy rate was higher than U-TPD (88% vs. 75%, P=.02). Mean IQ was similar among BMI 35–39.9, 40–44.9 and ≥45 groups [4.6 vs. 4.4 vs. 4.5, respectively (P=.6)]. No patient had a non-diagnostic stress scan. Conclusions In obese patients, HE-SPECT MPI with dedicated parallel-hole collimation demonstrated high image quality, normalcy rate, and diagnostic accuracy for CAD by quantitative analysis of combined upright/supine acquisitions. PMID:25388380
Selection of examples in case-based computer-aided decision systems
Mazurowski, Maciej A.; Zurada, Jacek M.; Tourassi, Georgia D.
2013-01-01
Case-based computer-aided decision (CB-CAD) systems rely on a database of previously stored, known examples when classifying new, incoming queries. Such systems can be particularly useful since they do not need retraining every time a new example is deposited in the case base. The adaptive nature of case-based systems is well suited to the current trend of continuously expanding digital databases in the medical domain. To maintain efficiency, however, such systems need sophisticated strategies to effectively manage the available evidence database. In this paper, we discuss the general problem of building an evidence database by selecting the most useful examples to store while satisfying existing storage requirements. We evaluate three intelligent techniques for this purpose: genetic algorithm-based selection, greedy selection and random mutation hill climbing. These techniques are compared to a random selection strategy used as the baseline. The study is performed with a previously presented CB-CAD system applied for false positive reduction in screening mammograms. The experimental evaluation shows that when the development goal is to maximize the system’s diagnostic performance, the intelligent techniques are able to reduce the size of the evidence database to 37% of the original database by eliminating superfluous and/or detrimental examples while at the same time significantly improving the CAD system’s performance. Furthermore, if the case-base size is a main concern, the total number of examples stored in the system can be reduced to only 2–4% of the original database without a decrease in the diagnostic performance. Comparison of the techniques shows that random mutation hill climbing provides the best balance between the diagnostic performance and computational efficiency when building the evidence database of the CB-CAD system. PMID:18854606
Fowler, J Christopher; Madan, Alok; Allen, Jon G; Patriquin, Michelle; Sharp, Carla; Oldham, John M; Frueh, B Christopher
2018-01-01
With the publication of DSM 5 alternative model for personality disorders it is critical to assess the components of the model against evidence-based models such as the five factor model and the DSM-IV-TR categorical model. This study explored the relative clinical utility of these models in screening for borderline personality disorder (BPD). Receiver operator characteristics and diagnostic efficiency statistics were calculated for three personality measures to ascertain the relative diagnostic efficiency of each measure. A total of 1653 adult inpatients at a specialist psychiatric hospital completed SCID-II interviews. Sample 1 (n=653) completed the SCID-II interviews, SCID-II Questionnaire (SCID-II-PQ) and the Big Five Inventory (BFI), while Sample 2 (n=1,000) completed the SCID-II interviews, Personality Inventory for DSM5 (PID-5) and the BFI. BFI measure evidenced moderate accuracy for two composites: High Neuroticism+ low agreeableness composite (AUC=0.72, SE=0.01, p<0.001) and High Neuroticism+ Low+Low Conscientiousness (AUC=0.73, SE=0.01, p<0.0001). The SCID-II-PQ evidenced moderate-to-excellent accuracy (AUC=0.86, SE=0.02, p<0.0001) with a good balance of specificity (SP=0.80) and sensitivity (SN=0.78). The PID-5 BPD algorithm (consisting of elevated emotional lability, anxiousness, separation insecurity, hostility, depressivity, impulsivity, and risk taking) evidenced moderate-to-excellent accuracy (AUC=0.87, SE=0.01, p<0.0001) with a good balance of specificity (SP=0.76) and sensitivity (SN=0.81). Findings generally support the use of SCID-II-PQ and PID-5 BPD algorithm for screening purposes. Furthermore, findings support the accuracy of the DSM 5 alternative model Criteria B trait constellation for diagnosing BPD. Limitations of the study include the single inpatient setting and use of two discrete samples to assess PID-5 and SCID-II-PQ. Copyright © 2017 Elsevier Inc. All rights reserved.
Rocha-Silva, Fabiana; Gomes, Luciana I; Gracielle-Melo, Cidiane; Goes, Alfredo M; Caligiorne, Rachel B
2017-01-01
Paracoccidioidomycosis (PCM) is a systemic mycosis caused by dimorphic fungi Paracoccidioides brasiliensis and Paracoccidioides lutzii. It is prevalent in Latin American, mainly in Brazil. Therefore, PCM has fundamental impact on the Brazilian global economy, especially in public health system, since it is affecting economical active population in different country regions. The present study aimed to standardize the Real Time-Polymerase Chain Reaction (rt-PCR) for an efficient and safe PCM diagnosis amplifying the recombinant protein PB27 gene, only expressed by specimens of Paracoccidioides genus. To standardize a methodology of rt-PCR using species-specific primers and probe designed for annealing in this specific region of the fungi´s genome, amplifying the recombinant protein PB27 gene, only expressed by specimens of Paracoccidioides genus. Followed by design in silico, experiments were performed in vitro to determine rt-PCR specificity, efficiency and genome detection limit. The primers and probe sequences were deposited in Brazilian Coordination of Technological Innovation and Transfer (CTIT), under patent reference number BR1020160078830. The present study demonstrated the rt-PCR applicability for support on diagnosis of paracoccidioidomycosis, presenting low cost, which makes it affordable for public health services in developing countries as Brazil. It is noteworthy that it is necessary to validate this methodology using clinical samples before to use as a safe method of diagnosis. A review of all patents related to this topic was performed and it was shown that, to date, there are no records of patent on kits for paracoccidioidomycosis´s diagnostic. Indeed, there is still a lot to go to reach this goal. The reaction developed was standardized and patented, opening perspectives to molecular diagnosis development for paracoccidioidomycosis, since rt-PCR can be applied to a broad spectrum of infectious diseases. It would need to be tested in biological samples in order to validate this method and then generate a diagnostic kit for Paracoccidioidomycosis. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Zeitoun, H; Bahey-El-Din, M; Kassem, M A; Aboushleib, H M
2017-12-01
Mycobacterium tuberculosis infection constitutes a global threat that results in significant morbidity and mortality worldwide. Efficient and early diagnosis of tuberculosis (TB) is of paramount importance for successful treatment. The aim of the current study is to investigate the mycobacterial mycothiol acetyltransferase Rv0819 as a potential novel biomarker for the diagnosis of active TB infection. The gene encoding Rv0819 was cloned and successfully expressed in Escherichia coli. The recombinant Rv0819 was purified using metal affinity chromatography and was used to raise murine polyclonal antibodies against Rv0819. The raised antibodies were employed for direct detection of Rv0819 in patient serum samples using dot blot assay and competitive enzyme-linked immunosorbent assay (ELISA). Serum samples were obtained from 68 confirmed new TB patients and 35 healthy volunteers as negative controls. The dot blot assay showed sensitivity of 64·7% and specificity of 100%, whereas the competitive ELISA assay showed lower sensitivity (54·4%) and specificity (88·57%). The overall sensitivity of the combined results of the two tests was found to be 89·7%. Overall, the mycobacterial Rv0819 is a potential TB serum biomarker that can be exploited, in combination with other TB biomarkers, for efficient and reliable diagnosis of active TB infection. The early and accurate diagnosis of tuberculosis infection is of paramount importance for initiating treatment and avoiding clinical complications. Most current diagnostic tests have poor sensitivity and/or specificity and in many cases they are too expensive for routine diagnostic testing in resource-limited settings. In the current study, we examined a novel mycobacterial serum biomarker, namely mycothiol acetyltransferase Rv0819. The antigen was detectable in serum specimens of a significant number of tuberculosis patients. This article proves the importance of Rv0819 and paves the way towards its future use as a useful diagnostic marker for tuberculosis infection. © 2017 The Society for Applied Microbiology.
Diagnostic criteria for adverse health effects in the environs of wind turbines.
McMurtry, Robert Y; Krogh, Carmen Me
2014-10-01
In an effort to address climate change, governments have pursued policies that seek to reduce greenhouse gases. Alternative energy, including wind power, has been proposed by some as the preferred approach. Few would debate the need to reduce air pollution, but the means of achieving this reduction is important not only for efficiency but also for health protection. The topic of adverse health effects in the environs of industrial wind turbines (AHE/IWT) has proven to be controversial and can present physicians with challenges regarding the management of an exposure to IWT. Rural physicians in particular must be aware of the possibility of people presenting to their practices with a variety of sometimes confusing complaints. An earlier version of the diagnostic criteria for AHE/IWT was published in August 2011. A revised case definition and a model for a study to establish a confirmed diagnosis is proposed.
Diagnostic criteria for adverse health effects in the environs of wind turbines
Krogh, Carmen ME
2014-01-01
Summary In an effort to address climate change, governments have pursued policies that seek to reduce greenhouse gases. Alternative energy, including wind power, has been proposed by some as the preferred approach. Few would debate the need to reduce air pollution, but the means of achieving this reduction is important not only for efficiency but also for health protection. The topic of adverse health effects in the environs of industrial wind turbines (AHE/IWT) has proven to be controversial and can present physicians with challenges regarding the management of an exposure to IWT. Rural physicians in particular must be aware of the possibility of people presenting to their practices with a variety of sometimes confusing complaints. An earlier version of the diagnostic criteria for AHE/IWT was published in August 2011. A revised case definition and a model for a study to establish a confirmed diagnosis is proposed. PMID:25383200
Niimi, Hideki; Ogawa, Tomomi; Note, Rhougou; Hayashi, Shirou; Ueno, Tomohiro; Harada, Kenu; Uji, Yoshinori; Kitajima, Isao
2010-12-01
In recent years, genetic diagnostics of pathogenic splicing abnormalities are increasingly recognized as critically important in the clinical genetic diagnostics. It is reported that approximately 10% of pathogenic mutations causing human inherited diseases are splicing mutations. Nonetheless, it is still difficult to identify splicing abnormalities in routine genetic diagnostic settings. Here, we studied two different kinds of cases with splicing abnormalities. The first case is a protein S deficiency. Nucleotide analyses revealed that the proband had a previously reported G to C substitution in the invariant AG dinucleotide at the splicing acceptor site of intronl/exon2, which produces multiple splicing abnormalities resulting in protein S deficiency. The second case is an antithrombin (AT) deficiency. This proband had a previously reported G to A substitution, at nucleotide position 9788 in intron 4, 14 bp in front of exon 5, which created a de novo exon 5 splice site and resulted in AT deficiency. From a practical standpoint, we discussed the pitfalls, attentions, and screening approaches in genetic diagnostics of pathogenic splicing abnormalities. Due to the difficulty with full-length sequence analysis of introns, and the lack of RNA samples, splicing mutations may escape identification. Although current genetic testing remains to be improved, to screen for splicing abnormalities more efficiently, it is significant to use an appropriate combination of various approaches such as DNA and/or RNA samples, splicing mutation databases, bioinformatic tools to detect splice sites and cis-regulatory elements, and in vitro and/or in vivo experimentally methods as needed.
Dry Eye Disease: Concordance Between the Diagnostic Tests in African Eyes.
Onwubiko, Stella N; Eze, Boniface I; Udeh, Nnenma N; Onwasigwe, Ernest N; Umeh, Rich E
2016-11-01
To assess the concordance between the diagnostic tests for dry eye disease (DED) in a Nigerian hospital population. The study was a hospital-based cross-sectional survey of adults (≥18 years) presenting at the eye clinic of the University of Nigeria Teaching Hospital (UNTH), Enugu; September-December, 2011. Participants' socio-demographic data were collected. Each subject was assessed for DED using the "Ocular Surface Disease Index" (OSDI) questionnaire, tear-film breakup time (TBUT), and Schirmer test. The intertest concordance was assessed using kappa statistic, correlation, and regression coefficients. The participants (n=402; men: 193) were aged 50.1±19.1 standard deviation years (range: 18-94 years). Dry eye disease was diagnosed in 203 by TBUT, 170 by Schirmer test, and 295 by OSDI; the concordance between the tests were OSDI versus TBUT (Kappa, κ=-0.194); OSDI versus Schirmer (κ=-0.276); and TBUT versus Schirmer (κ=0.082). Ocular Surface Disease Index was inversely correlated with Schirmer test (Spearman ρ=-0.231, P<0.001) and TBUT (ρ=-0.237, P<0.001). In the linear regression model, OSDI was poorly predicted by TBUT (β=-0.09; 95% confidence interval (CI): -0.26 to -0.03, P=0.14) and Schirmer test (β=-0.35, 95% CI: -0.53 to -0.18, P=0.18). At UNTH, there is poor agreement, and almost equal correlation, between the subjective and objective tests for DED. Therefore, the selection of diagnostic test for DED should be informed by cost-effectiveness and diagnostic resource availability, not diagnostic efficiency or utility.
Douglas, Pamela S; Hoffmann, Udo; Lee, Kerry L; Mark, Daniel B; Al-Khalidi, Hussein R; Anstrom, Kevin; Dolor, Rowena J; Kosinski, Andrzej; Krucoff, Mitchell W; Mudrick, Daniel W; Patel, Manesh R; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Cooper, Lawton
2014-06-01
Suspected coronary artery disease (CAD) is one of the most common, potentially life-threatening diagnostic problems clinicians encounter. However, no large outcome-based randomized trials have been performed to guide the selection of diagnostic strategies for these patients. The PROMISE study is a prospective, randomized trial comparing the effectiveness of 2 initial diagnostic strategies in patients with symptoms suspicious for CAD. Patients are randomized to either (1) functional testing (exercise electrocardiogram, stress nuclear imaging, or stress echocardiogram) or (2) anatomical testing with ≥64-slice multidetector coronary computed tomographic angiography. Tests are interpreted locally in real time by subspecialty certified physicians, and all subsequent care decisions are made by the clinical care team. Sites are provided results of central core laboratory quality and completeness assessment. All subjects are followed up for ≥1 year. The primary end point is the time to occurrence of the composite of death, myocardial infarction, major procedural complications (stroke, major bleeding, anaphylaxis, and renal failure), or hospitalization for unstable angina. More than 10,000 symptomatic subjects were randomized in 3.2 years at 193 US and Canadian cardiology, radiology, primary care, urgent care, and anesthesiology sites. Multispecialty community practice enrollment into a large pragmatic trial of diagnostic testing strategies is both feasible and efficient. The PROMISE trial will compare the clinical effectiveness of an initial strategy of functional testing against an initial strategy of anatomical testing in symptomatic patients with suspected CAD. Quality of life, resource use, cost-effectiveness, and radiation exposure will be assessed. Copyright © 2014 Mosby, Inc. All rights reserved.
Douglas, Pamela S.; Hoffmann, Udo; Lee, Kerry L.; Mark, Daniel B.; Al-Khalidi, Hussein R.; Anstrom, Kevin; Dolor, Rowena J.; Kosinski, Andrzej; Krucoff, Mitchell W.; Mudrick, Daniel W.; Patel, Manesh R.; Picard, Michael H.; Udelson, James E.; Velazquez, Eric J.; Cooper, Lawton
2014-01-01
Background Suspected coronary artery disease (CAD) is one of the most common, potentially life threatening diagnostic problems clinicians encounter. However, no large outcome-based randomized trials have been performed to guide the selection of diagnostic strategies for these patients. Methods The PROMISE study is a prospective, randomized trial comparing the effectiveness of two initial diagnostic strategies in patients with symptoms suspicious for CAD. Patients are randomized to either: 1) functional testing (exercise electrocardiogram, stress nuclear imaging, or stress echocardiogram); or 2) anatomic testing with >=64 slice multidetector coronary computed tomographic angiography. Tests are interpreted locally in real time by subspecialty certified physicians and all subsequent care decisions are made by the clinical care team. Sites are provided results of central core lab quality and completeness assessment. All subjects are followed for ≥1 year. The primary end-point is the time to occurrence of the composite of death, myocardial infarction, major procedural complications (stroke, major bleeding, anaphylaxis and renal failure) or hospitalization for unstable angina. Results Over 10,000 symptomatic subjects were randomized in 3.2 years at 193 US and Canadian cardiology, radiology, primary care, urgent care and anesthesiology sites. Conclusion Multi-specialty community practice enrollment into a large pragmatic trial of diagnostic testing strategies is both feasible and efficient. PROMISE will compare the clinical effectiveness of an initial strategy of functional testing against an initial strategy of anatomic testing in symptomatic patients with suspected CAD. Quality of life, resource use, cost effectiveness and radiation exposure will be assessed. Clinical trials.gov identifier NCT01174550 PMID:24890527
NASA Astrophysics Data System (ADS)
Zissis, Georges; Haverlag, Marco
2010-06-01
Light sources play an indispensable role in the daily life of any human being. Quality of life, health and urban security related to traffic and crime prevention depend on light and on its quality. In fact, every day approximately 30 billion electric light sources operate worldwide. These electric light sources consume almost 19% of worldwide electricity production. Finding new ways to light lamps is a challenge where the stakes are scientific, technological, economic and environmental. The production of more efficient light sources is a sustainable solution for humanity. There are many opportunities for not only enhancing the efficiency and reliability of lighting systems but also for improving the quality of light as seen by the end user. This is possible through intelligent use of new technologies, deep scientific understanding of the operating principles of light sources and knowledge of the varied human requirements for different types of lighting in different settings. A revolution in the domain of light source technology is on the way: high brightness light emitting diodes arriving in the general lighting market, together with organic LEDs (OLEDs), are producing spectacular advances. However, unlike incandescence, electrical discharge lamps are far from disappearing from the market. In addition, new generations of discharge lamps based on molecular radiators are becoming a reality. There are still many scientific and technological challenges to be raised in this direction. Diagnostics are important for understanding the fundamental mechanisms taking place in the discharge plasma. This understanding is an absolute necessity for system optimization leading to more efficient and high quality light sources. The studied medium is rather complex, but new diagnostic techniques coupled to innovative ideas and powerful tools have been developed in recent years. This cluster issue of seven papers illustrates these efforts. The selected papers cover all domains, from high to low pressure and dielectric barrier lamps, from breakdown to acoustic resonance. Especially in the domain of high pressure lamps, J J Curry shows how coherent and incoherent x-ray scattering can be used as an imaging technique adapted to lamps. J Hirsch et al treat the acoustic resonance phenomenon that seriously limits the frequency domain for high pressure lamp operation. M Jinno et al illustrate a method that allows for measuring Xe buffer gas pressure in Hg-free metal halide lamps for automotive applications. In the domain of low pressure lamps, M Gendre et al investigate the breakdown phase by means of optical and electrical diagnostic tools. The similarity rules used a long time ago for simulating plasma behaviour based on invariants are now serving as diagnostic tools, as shown in the paper by D Michael et al. N Dagang et al show how impurities can be detected in Hg-free electrodeless lamps and more particularly in dielectric barrier discharges emitting excimer radiation. The quality of light is illustrated by a final example by R Kozakov et al on how to qualify the light output from the lamp with respect to biological effects on humans.
Should the diagnostic and therapeutic protocols for adrenal incidentalomas be changed?
Mateo-Gavira, Isabel; Vilchez-López, Francisco Javier; Larrán-Escandón, Laura; Ojeda-Schuldt, María Belén; Tinoco, Cristina López; Aguilar-Diosdado, Manuel
2015-01-01
The prevalence of adrenal incidentalomas is increasing with the aging of the population and the use of high resolution imaging technics. Current protocols propose a comprehensive monitoring of their functional and morphological state, but with no conclusive clinical evidence that endorses it. Retrospective study of 96 patients diagnosed with adrenal incidentaloma between 2008 and 2012. We evaluated clinical, functional and imaging at baseline and during follow-up. Initially, 9 cases were surgically removed: 4 due to hyperfunction (2 Cushing syndromes and 2 pheochromocytomas) and 5 due to size larger than 4cm. During follow-up one case of pheochromocytoma was diagnosed and another grew more than 1cm, needing surgery. In 98.86% of nonfunctional and benign lesions, there was no functional and/or morphological changes in the final evaluation. The results of our study challenge the validity of current diagnostic-therapeutic protocols of incidentalomas, which should be reassessed in prospective studies taking into account efficiency characteristics. Copyright © 2013 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Tsai, Chen-An; Lee, Kuan-Ting; Liu, Jen-Pei
2016-01-01
A key feature of precision medicine is that it takes individual variability at the genetic or molecular level into account in determining the best treatment for patients diagnosed with diseases detected by recently developed novel biotechnologies. The enrichment design is an efficient design that enrolls only the patients testing positive for specific molecular targets and randomly assigns them for the targeted treatment or the concurrent control. However there is no diagnostic device with perfect accuracy and precision for detecting molecular targets. In particular, the positive predictive value (PPV) can be quite low for rare diseases with low prevalence. Under the enrichment design, some patients testing positive for specific molecular targets may not have the molecular targets. The efficacy of the targeted therapy may be underestimated in the patients that actually do have the molecular targets. To address the loss of efficiency due to misclassification error, we apply the discrete mixture modeling for time-to-event data proposed by Eng and Hanlon [8] to develop an inferential procedure, based on the Cox proportional hazard model, for treatment effects of the targeted treatment effect for the true-positive patients with the molecular targets. Our proposed procedure incorporates both inaccuracy of diagnostic devices and uncertainty of estimated accuracy measures. We employed the expectation-maximization algorithm in conjunction with the bootstrap technique for estimation of the hazard ratio and its estimated variance. We report the results of simulation studies which empirically investigated the performance of the proposed method. Our proposed method is illustrated by a numerical example.
Efficient statistical tests to compare Youden index: accounting for contingency correlation.
Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan
2015-04-30
Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.
Dante Soft X-ray Power Diagnostic for NIF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewald, E; Campbell, K; Turner, R
2004-04-15
Soft x-ray power diagnostics are essential for measuring spectrally resolved the total x-ray flux, radiation temperature, conversion efficiency and albedo that are important quantities for the energetics of indirect drive hohlraums. At the Nova or Omega Laser Facilities, these measurements are performed mainly with Dante, but also with DMX and photo-conductive detectors (PCD's). The Dante broadband spectrometer is a collection of absolute calibrated vacuum x-ray diodes, thin filters and x-ray mirrors used to measure the soft x-ray emission for photon energies above 50 eV.
Open Energy Information System version 2.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
OpenEIS was created to provide standard methods for authoring, sharing, testing, using, and improving algorithms for operational building energy efficiency with building managers and building owners. OpenEIS is designed as a no-cost/low-cost solution that will propagate the fault detection and diagnostic (FDD) solutions into the marketplace by providing state- of- the-art analytical and diagnostic algorithms. As OpenEIS penetrates the market, demand by control system manufacturers and integrators serving small and medium commercial customers will help push these types of commercial software tool offerings into the broader marketplace.
How clinicians should use the diagnostic laboratory in a changing medical world.
Lundberg, G D
1999-02-01
In developed countries, clinicians are faced with a plethora of diagnostic tests to apply to patients to guide their clinical management. The quality, effectiveness, and efficiency of patient care should be foremost in the clinician's mind. Laboratory directors should make every effort to guide clinicians in appropriate laboratory test ordering, interpretation, and resulting actions. Medicine, being at its center a moral enterprise grounded in a covenant of trust, and laboratory medicine being a subset of medicine, must first care and advocate for the patient, and consider clinical outcomes as most important.
Rolling bearing fault diagnosis based on information fusion using Dempster-Shafer evidence theory
NASA Astrophysics Data System (ADS)
Pei, Di; Yue, Jianhai; Jiao, Jing
2017-10-01
This paper presents a fault diagnosis method for rolling bearing based on information fusion. Acceleration sensors are arranged at different position to get bearing vibration data as diagnostic evidence. The Dempster-Shafer (D-S) evidence theory is used to fuse multi-sensor data to improve diagnostic accuracy. The efficiency of the proposed method is demonstrated by the high speed train transmission test bench. The results of experiment show that the proposed method in this paper improves the rolling bearing fault diagnosis accuracy compared with traditional signal analysis methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sjoberg, Carl Magnus Goran; Vuilleumier, David
Ever tighter fuel economy standards and concerns about energy security motivate efforts to improve engine efficiency and to develop alternative fuels. This project contributes to the science base needed by industry to develop highly efficient direct injection spark ignition (DISI) engines that also beneficially exploit the different properties of alternative fuels. Here, the emphasis is on lean operation, which can provide higher efficiencies than traditional non-dilute stoichiometric operation. Since lean operation can lead to issues with ignition stability, slow flame propagation and low combustion efficiency, the focus is on techniques that can overcome these challenges. Specifically, fuel stratification is usedmore » to ensure ignition and completeness of combustion but this technique has soot and NOx emissions challenges. For ultra-lean well-mixed operation, turbulent deflagration can be combined with controlled end-gas autoignition to render mixed-mode combustion for sufficiently fast heat release. However, such mixed-mode combustion requires very stable inflammation, motivating studies on the effects of near-spark flow and turbulence, and the use of small amounts of fuel stratification near the spark plug.« less
Dickstein, Benjamin D; Weathers, Frank W; Angkaw, Abigail C; Nievergelt, Caroline M; Yurgil, Kate; Nash, William P; Baker, Dewleen G; Litz, Brett T
2015-06-01
The aim of this study was to determine optimally efficient cutoff scores on the Posttraumatic Stress Disorder Checklist (PCL) for identifying full posttraumatic stress disorder (PTSD) and partial PTSD (P-PTSD) in active-duty Marines and Sailors. Participants were 1,016 Marines and Sailors who were administered the PCL and Clinician-Administered PTSD Scale (CAPS) 3 months after returning from Operations Iraqi and Enduring Freedom. PCL cutoffs were tested against three CAPS-based classifications: full PTSD, stringent P-PTSD, and lenient P-PTSD. A PCL score of 39 was found to be optimally efficient for identifying full PTSD. Scores of 38 and 33 were found to be optimally efficient for identifying stringent and lenient P-PTSD, respectively. Findings suggest that the PCL cutoff that is optimally efficient for detecting PTSD in active-duty Marines and Sailors is substantially lower than the score of 50 commonly used by researchers. In addition, findings provide scores useful for identifying P-PTSD in returning service members. © The Author(s) 2014.
Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2005)
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...
Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2003)
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...
Wang, Chuanyuan; Chen, Bing; Zhang, Baiyu; Guo, Ping; Zhao, Mingming
2014-01-01
The composition and distribution of triaromatic steroid hydrocarbons in oil residues after biodegradation and photo-oxidation processes were detected, and the diagnostic ratios for oil spill identification were developed and evaluated based on the relative standard deviation (RSD) and the repeatability limit. The preferential loss of C27 methyl triaromatic steranes (MTAS) relative to C28 MTAS and C29 MTAS was shown during the photo-oxidation process. In contrast to the photochemical degradation, the MTAS with the original 20R biological configuration was preferentially degraded during the biodegradation process. The RSD of most of the diagnostic ratios of MTAS ranged from 9 to 84% during the photo-oxidation process. However, the RSDs of such ratios derived from MTAS were all <5% even in high biodegradation, and such parameters may also provide new methods on oil spill identification. The parameters of monoaromatic sterane and monoaromatic sterane are not used well for oil spill identification after photo-oxidation. The triaromatic steroid hydrocarbons retained their molecular compositions after biodegradation and photo-oxidation and most of the diagnostic ratios derived from them could be efficiently used in oil spill identification.
Shrivastava, Kamal; Garima, Kushal; Narang, Anshika; Bhattacharyya, Kausik; Vishnoi, Ekta; Singh, Roshan Kumar; Chaudhry, Anil; Prasad, Rajendra; Bose, Mridula; Varma-Basil, Mandira
2017-03-01
We explored the efficiency of Rv1458c, the gene encoding a putative ABC drug transporter specific for the Mycobacterium tuberculosis complex (MTBC), as a diagnostic marker. A 190 bp region of Rv1458c and a 300 bp region of hsp65 were targeted in a novel duplex PCR assay and the results were compared with those for PCR restriction analysis(PRA) using the restriction enzymes NruI and BamHI. Species identification of a subset of the isolates (n=50) was confirmed by sequencing. Clinical isolates of M. tuberculosis (n=426) obtained from clinically suspected patients of pulmonary tuberculosis and mycobacterial (n=13) and non-mycobacterial (n=8) reference strains were included in the study. The duplex PCR assay correctly identified 320/426 isolates as MTBC and 106/426 isolates as non-tuberculous mycobacteria(NTM). The test was 100 % specific and sensitive when compared with NruI/BamHI PCR restriction analysis and highlighted the use of Rv1458c as a diagnostic marker for MTBC. The duplex PCR assay could be developed for use as a screening test to identify MTBC in clinical specimens in peripheral laboratories with limited resources.
Rapid DNA extraction from dried blood spots on filter paper: potential applications in biobanking.
Choi, Eun-Hye; Lee, Sang Kwang; Ihm, Chunhwa; Sohn, Young-Hak
2014-12-01
Dried blood spot (DBS) technology is a microsampling alternative to traditional plasma or serum sampling for pharmaco- or toxicokinetic evaluation. DBS technology has been applied to diagnostic screening in drug discovery, nonclinical, and clinical settings. We have developed an improved elution protocol involving boiling of blood spots dried on Whatman filter paper. The purpose of this study was to compare the quality, purity, and quantity of DNA isolated from frozen blood samples and DBSs. We optimized a method for extraction and estimation of DNA from blood spots dried on filter paper (3-mm FTA card). A single DBS containing 40 μL blood was used. DNA was efficiently extracted in phosphate-buffered saline (PBS) or Tris-EDTA (TE) buffer by incubation at 37°C overnight. DNA was stable in DBSs that were stored at room temperature or frozen. The housekeeping genes GAPDH and beta-actin were used as positive standards for polymerase chain reaction (PCR) validation of general diagnostic screening. Our simple and convenient DBS storage and extraction methods are suitable for diagnostic screening by using very small volumes of blood collected on filter paper, and can be used in biobanks for blood sample storage.
Mengist, Hylemariam Mihiretie; Demeke, Gebreselassie; Zewdie, Olifan; Belew, Adugna
2018-05-04
The aim of this study was to evaluate the diagnostic performance of direct wet mount microscopy compared to formalin ether concentration (FEC) technique in detecting intestinal helminths in pregnant women. The total prevalence of intestinal helminths was 18.8% (70/372) by direct wet mount microscopy and 24.7% (92/372) by FEC technique (P < 0.001). The sensitivity, negative predictive value (NPV) and test efficiency (TE) of direct wet mount microscopy in diagnosing intestinal helminths was 76, 92.7 and 94%, respectively. The sensitivity of direct w et mount microscopy was very low in detecting ova of Hymenolepis nana. The two methods showed excellent agreement in detecting ova of Hook worm and Ascaris lumbricoides (Kappa > 0.81) but they fairly agreed in detecting ova of Hymenolepis nana (Kappa = 0.39). Intestinal helminths were underdiagnosed and the total diagnostic performance of direct wet mount microscopy was significantly poor in detecting intestinal helminths as compared to FEC technique. Routine use of FEC method is recommended for the diagnosis of intestinal helminths in pregnant women.
Qiao, Tian-Min; Zhang, Jing; Li, Shu-Jiang; Han, Shan; Zhu, Tian-Hui
2016-10-01
Eucalyptus dieback disease, caused by Cylindrocladium scoparium , has occurred in last few years in large Eucalyptus planting areas in China and other countries. Rapid, simple, and reliable diagnostic techniques are desired for the early detection of Eucalyptus dieback of C. scoparium prior to formulation of efficient control plan. For this purpose, three PCR-based methods of nested PCR, multiplex PCR, loop-mediated isothermal amplification (LAMP) were developed for detection of C. scoparium based on factor 1-alpha (tef1) and beta-tubulin gene in this study. All of the three methods showed highly specific to C. scoparium . The sensitivities of the nested PCR and LAMP were much higher than the multiplex PCR. The sensitivity of multiplex PCR was also higher than regular PCR. C. scoparium could be detected within 60 min from infected Eucalyptus plants by LAMP, while at least 2 h was needed by the rest two methods. Using different Eucalyptus tissues as samples for C. scoparium detection, all of the three PCR-based methods showed much better detection results than regular PCR. Base on the results from this study, we concluded that any of the three PCR-based methods could be used as diagnostic technology for the development of efficient strategies of Eucalyptus dieback disease control. Particularly, LAMP was the most practical method in field application because of its one-step and rapid reaction, simple operation, single-tube utilization, and simple visualization of amplification products.
Qiao, Tian-Min; Zhang, Jing; Li, Shu-Jiang; Han, Shan; Zhu, Tian-Hui
2016-01-01
Eucalyptus dieback disease, caused by Cylindrocladium scoparium, has occurred in last few years in large Eucalyptus planting areas in China and other countries. Rapid, simple, and reliable diagnostic techniques are desired for the early detection of Eucalyptus dieback of C. scoparium prior to formulation of efficient control plan. For this purpose, three PCR-based methods of nested PCR, multiplex PCR, loop-mediated isothermal amplification (LAMP) were developed for detection of C. scoparium based on factor 1-alpha (tef1) and beta-tubulin gene in this study. All of the three methods showed highly specific to C. scoparium. The sensitivities of the nested PCR and LAMP were much higher than the multiplex PCR. The sensitivity of multiplex PCR was also higher than regular PCR. C. scoparium could be detected within 60 min from infected Eucalyptus plants by LAMP, while at least 2 h was needed by the rest two methods. Using different Eucalyptus tissues as samples for C. scoparium detection, all of the three PCR-based methods showed much better detection results than regular PCR. Base on the results from this study, we concluded that any of the three PCR-based methods could be used as diagnostic technology for the development of efficient strategies of Eucalyptus dieback disease control. Particularly, LAMP was the most practical method in field application because of its one-step and rapid reaction, simple operation, single-tube utilization, and simple visualization of amplification products. PMID:27721691
Royer, Jessica; Blais, Caroline; Barnabé-Lortie, Vincent; Carré, Mélissa; Leclerc, Josiane; Fiset, Daniel
2016-06-01
Faces are encountered in highly diverse angles in real-world settings. Despite this considerable diversity, most individuals are able to easily recognize familiar faces. The vast majority of studies in the field of face recognition have nonetheless focused almost exclusively on frontal views of faces. Indeed, a number of authors have investigated the diagnostic facial features for the recognition of frontal views of faces previously encoded in this same view. However, the nature of the information useful for identity matching when the encoded face and test face differ in viewing angle remains mostly unexplored. The present study addresses this issue using individual differences and bubbles, a method that pinpoints the facial features effectively used in a visual categorization task. Our results indicate that the use of features located in the center of the face, the lower left portion of the nose area and the center of the mouth, are significantly associated with individual efficiency to generalize a face's identity across different viewpoints. However, as faces become more familiar, the reliance on this area decreases, while the diagnosticity of the eye region increases. This suggests that a certain distinction can be made between the visual mechanisms subtending viewpoint invariance and face recognition in the case of unfamiliar face identification. Our results further support the idea that the eye area may only come into play when the face stimulus is particularly familiar to the observer. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kaplan, Daniel M
2010-10-01
The author argues that the well-formulated problem list is essential for both organizing and evaluating diagnostic thinking. He considers evidence of deficiencies in problem lists in the medical record. He observes a trend among medical trainees toward organizing notes in the medical record according to lists of organ systems or medical subspecialties and hypothesizes that system-based documentation may undermine the art of problem formulation and diagnostic synthesis. Citing research linking more sophisticated problem representation with diagnostic success, he suggests that documentation style and clinical reasoning are closely connected and that organ-based documentation may predispose trainees to several varieties of cognitive diagnostic error and deficient synthesis. These include framing error, premature or absent closure, failure to integrate related findings, and failure to recognize the level of diagnostic resolution attained for a given problem. He acknowledges the pitfalls of higher-order diagnostic resolution, including the application of labels unsupported by firm evidence, while maintaining that diagnostic resolution as far as evidence permits is essential to both rational care of patients and rigorous education of learners. He proposes further research, including comparison of diagnostic efficiency between organ- and problem-oriented thinkers. He hypothesizes that the subspecialty-based structure of academic medical services helps perpetuate organ-system-based thinking, and calls on clinical educators to renew their emphasis on the formulation and documentation of complete and precise problem lists and progressively refined diagnoses by trainees.
Qamar, Irmeen; Rehman, Suhailur; Mehdi, Ghazala; Maheshwari, Veena; Ansari, Hena A.; Chauhan, Sunanda
2018-01-01
Background: Cytologic examination of body fluids commonly involves the use of direct or sediment smears, cytocentrifuge preparations, membrane filter preparations, or cell block sections. Cytospin and cell block techniques are extremely useful in improving cell yield of thin serous effusions and urine samples, and ensure high diagnostic efficacy. Materials and Methods: We studied cytospin preparations and cell block sections prepared from 180 samples of body fluids and urine samples to compare the relative efficiency of cell retrieval, preservation of cell morphology, ease of application of special stains, and diagnostic efficacy. Samples were collected and processed to prepare cytospin smears and cell block sections. Results: We observed that overall, cell yield and preservation of individual cell morphology were better in cytospin preparations as compared to cell blocks, while preservation of architectural pattern was better in cell block sections. The number of suspicious cases also decreased on cell block sections, with increased detection of malignancy. It was difficult to prepare cell blocks from urine samples due to low cellularity. Conclusions: Cytospin technology is a quick, efficient, and cost-effective method of increasing cell yield in hypocellular samples, with better preservation of cell morphology. Cell blocks are better prepared from high cellularity fluids; however, tissue architecture is better studied, with improved rate of diagnosis and decrease in ambiguous results. Numerous sections can be prepared from a small amount of material. Special stains and immunochemical stains can be easily applied to cell blocks. It also provides a source of archival material. PMID:29643653
The time-efficiency principle: time as the key diagnostic strategy in primary care.
Irving, Greg; Holden, John
2013-08-01
The test and retest opportunity afforded by reviewing a patient over time substantially increases the total gain in certainty when making a diagnosis in low-prevalence settings (the time-efficiency principle). This approach safely and efficiently reduces the number of patients who need to be formally tested in order to make a correct diagnosis for a person. Time, in terms of observed disease trajectory, provides a vital mechanism for achieving this task. It remains the best strategy for delivering near-optimal diagnoses in low-prevalence settings and should be used to its full advantage.
NASA Astrophysics Data System (ADS)
Krupka, M.; Kalal, M.; Dostal, J.; Dudzak, R.; Juha, L.
2017-08-01
Classical interferometry became widely used method of active optical diagnostics. Its more advanced version, allowing reconstruction of three sets of data from just one especially designed interferogram (so called complex interferogram) was developed in the past and became known as complex interferometry. Along with the phase shift, which can be also retrieved using classical interferometry, the amplitude modifications of the probing part of the diagnostic beam caused by the object under study (to be called the signal amplitude) as well as the contrast of the interference fringes can be retrieved using the complex interferometry approach. In order to partially compensate for errors in the reconstruction due to imperfections in the diagnostic beam intensity structure as well as for errors caused by a non-ideal optical setup of the interferometer itself (including the quality of its optical components), a reference interferogram can be put to a good use. This method of interferogram analysis of experimental data has been successfully implemented in practice. However, in majority of interferometer setups (especially in the case of the ones employing the wavefront division) the probe and the reference part of the diagnostic beam would feature different intensity distributions over their respective cross sections. This introduces additional error into the reconstruction of the signal amplitude and the fringe contrast, which cannot be resolved using the reference interferogram only. In order to deal with this error it was found that additional separately recorded images of the intensity distribution of the probe and the reference part of the diagnostic beam (with no signal present) are needed. For the best results a sufficient shot-to-shot stability of the whole diagnostic system is required. In this paper, efficiency of the complex interferometry approach for obtaining the highest possible accuracy of the signal amplitude reconstruction is verified using the computer generated complex and reference interferograms containing artificially introduced intensity variations in the probe and the reference part of the diagnostic beam. These sets of data are subsequently analyzed and the errors of the signal amplitude reconstruction are evaluated.
Appleby, Ryan; Zur Linden, Alex; Sears, William
2017-05-01
Diagnostic imaging plays an important role in the operating room, providing surgeons with a reference and surgical plan. Surgeon autonomy in the operating room has been suggested to decrease errors that stem from communication mistakes. A standard computer mouse was compared to a wireless remote-control style controller for computer game consoles (Wiimote) for the navigation of diagnostic imaging studies by sterile personnel in this prospective survey study. Participants were recruited from a cohort of residents and faculty that use the surgical suites at our institution. Outcome assessments were based on survey data completed by study participants following each use of either the mouse or Wiimote, and compared using an analysis of variance. The mouse was significantly preferred by the study participants in the categories of handling, accuracy and efficiency, and overall satisfaction (P <0.05). The mouse was preferred to both the Wiimote and to no device, when participants were asked to rank options for image navigation. This indicates the need for the implementation of intraoperative image navigation devices, to increase surgeon autonomy in the operating room. © 2017 American College of Veterinary Radiology.
Orduña, Antonio; Almaraz, Ana; Prado, Ana; Gutierrez, M. Purificación; Garcia-Pascual, Agustina; Dueñas, Ana; Cuervo, Milagros; Abad, Ramon; Hernández, Beatriz; Lorenzo, Belen; Bratos, Miguel A.; Torres, Antonio Rodriguez
2000-01-01
We evaluated the validity and the usefulness of a new test for the diagnosis of human brucellosis based on an immunocapture-agglutination technique. A total of 315 sera from 82 patients with a diagnosis of brucellosis, 157 sera from patients in whom brucellosis was suspected but not confirmed, and 412 sera from people living in rural areas with endemic brucellosis were studied. The seroagglutination test (SAT), Coombs anti-Brucella test, and Brucellacapt test were evaluated. All the initial sera from the 82 patients proved to be positive in Brucellacapt and Coombs tests, while only 75 (91.4%) were positive in the SAT. If a ≥1/160 diagnostic threshold titer was defined for the Brucellacapt test, Coombs test, and SAT, the sensitivities were 95.1, 91.5, and 65.8%, respectively. Taking the same diagnostic threshold titer for the 157 sera from the unconfirmed but suspected patients, the specificities of the Brucellacapt, Coombs, and SAT were 81.5, 96.2, and 100%, respectively; for the 412 control sera, the specificities were 99.0, 99.8, and 100%. The diagnostic efficiency (area below the receiver operating characteristic curve) of Brucellacapt was 0.987852 (95% confidence interval [CI], 0.95109 to 0.99286), very similar to the diagnostic efficiency of the Coombs test (0.97611; 95% CI, 0.94781 to 0.99146) and higher than that of SAT (0.91013; 95% CI, 0.86649 to 0.94317). The results of the Brucellacapt test were compared with those of the Coombs test (correlation coefficient, 0.956; P = 0.000) and SAT (correlation coefficient, 0.866; P = 0.000). The study shows very good correlation between the Brucellacapt and Coombs tests, with a high concordance between titers obtained in the two tests. Nevertheless, lower correlation and concordance were found between the Brucellacapt and Coombs tests when the results for titers of ≥1/160 were compared (0.692; P = 0.000). In acute brucellosis, the Brucellacapt and Coombs tests render positive titers of ≥1/160. When the titers are lower, they increase significantly in the following 30 days, despite the evolution of SAT titers. In contrast, Brucellacapt and Coombs titers are always high (≥1/640) in brucellosis with long evolution, whether SAT titers are higher or lower than 1/160. PMID:11060059
Beam diagnostics at high-intensity storage rings
NASA Astrophysics Data System (ADS)
Plum, Mike
1994-10-01
Beam diagnostics at high-intensity facilities feature their own special set of problems and characteristics, issues peculiar to high-intensity storage rings include beam loss, beam halos, extraction efficiency, beam in the gap, clearing electrodes, and beam-profile measurement. The Los Alamos Proton Storage Ring (PSR) is a nice example of a high-intensity storage ring. I will discuss in some detail three diagnostic systems currently in use at the PSR: the beam-loss-monitor system, the electron-clearing system, and the beam-in-the-gap monitor. Much of our discussion is inspired by the problems we have encountered and the useful things we have learned while commissioning and developing the PSR. Another inspiration is our work on the next-generation neutron-spallation source, also known as the National Center for Neutron Research (NCNR).
Wu, Mixia; Shu, Yu; Li, Zhaohai; Liu, Aiyi
2016-01-01
A sequential design is proposed to test whether the accuracy of a binary diagnostic biomarker meets the minimal level of acceptance. The accuracy of a binary diagnostic biomarker is a linear combination of the marker’s sensitivity and specificity. The objective of the sequential method is to minimize the maximum expected sample size under the null hypothesis that the marker’s accuracy is below the minimal level of acceptance. The exact results of two-stage designs based on Youden’s index and efficiency indicate that the maximum expected sample sizes are smaller than the sample sizes of the fixed designs. Exact methods are also developed for estimation, confidence interval and p-value concerning the proposed accuracy index upon termination of the sequential testing. PMID:26947768
Zhang, Yu; Yu, Li-Ke; Xia, Ning
2012-03-01
To evaluate the diagnostic value of endostatin (ES), vascular endothelial growth factor (VEGF) and carcinoembryonic antigen (CEA) in both serum and pleural effusion of lung cancer patients. Levels of ES, VEGF and CEA in 52 malignant pleural effusion due to lung cancer and 50 patients with non-malignant disease were measured by using sandwich enzyme-linked immunosorbent assay and microparticle enzyme immunoassay. The ES, VEGF and CEA levels in pleural effusion and serum, and their ratio (F/S) were higher in lung cancer group than that in benign group, and the differences were statistically significant (P<0.05). The diagnostic efficiency of ES+VEGF for lung cancer was superior to either single detection. The diagnostic efficiency of ES+VEGF+CEA was superior to either ES+VEGF or ES+CEA. The results suggest that ES, VEGF and CEA might be useful in the differentiation between benign and malignant pleural effusion due to lung cancer. In comparison with either single determination of concentration in serum or pleural fluid, the combined detection of two or three markers is of important clinical significance in the diagnosis of lung cancer. Copyright © 2012 Hainan Medical College. Published by Elsevier B.V. All rights reserved.
Bhaumik, Basabi
2016-01-01
A novel algorithm based on forward search is developed for real-time electrocardiogram (ECG) signal processing and implemented in application specific integrated circuit (ASIC) for QRS complex related cardiovascular disease diagnosis. The authors have evaluated their algorithm using MIT-BIH database and achieve sensitivity of 99.86% and specificity of 99.93% for QRS complex peak detection. In this Letter, Physionet PTB diagnostic ECG database is used for QRS complex related disease detection. An ASIC for cardiovascular disease detection is fabricated using 130-nm CMOS high-speed process technology. The area of the ASIC is 0.5 mm2. The power dissipation is 1.73 μW at the operating frequency of 1 kHz with a supply voltage of 0.6 V. The output from the ASIC is fed to their Android application that generates diagnostic report and can be sent to a cardiologist through email. Their ASIC result shows average failed detection rate of 0.16% for six leads data of 290 patients in PTB diagnostic ECG database. They also have implemented a low-leakage version of their ASIC. The ASIC dissipates only 45 pJ with a supply voltage of 0.9 V. Their proposed ASIC is most suitable for energy efficient telemetry cardiovascular disease detection system. PMID:27284458
Jain, Sanjeev Kumar; Bhaumik, Basabi
2016-03-01
A novel algorithm based on forward search is developed for real-time electrocardiogram (ECG) signal processing and implemented in application specific integrated circuit (ASIC) for QRS complex related cardiovascular disease diagnosis. The authors have evaluated their algorithm using MIT-BIH database and achieve sensitivity of 99.86% and specificity of 99.93% for QRS complex peak detection. In this Letter, Physionet PTB diagnostic ECG database is used for QRS complex related disease detection. An ASIC for cardiovascular disease detection is fabricated using 130-nm CMOS high-speed process technology. The area of the ASIC is 0.5 mm(2). The power dissipation is 1.73 μW at the operating frequency of 1 kHz with a supply voltage of 0.6 V. The output from the ASIC is fed to their Android application that generates diagnostic report and can be sent to a cardiologist through email. Their ASIC result shows average failed detection rate of 0.16% for six leads data of 290 patients in PTB diagnostic ECG database. They also have implemented a low-leakage version of their ASIC. The ASIC dissipates only 45 pJ with a supply voltage of 0.9 V. Their proposed ASIC is most suitable for energy efficient telemetry cardiovascular disease detection system.
Sensor gas analyzer for acetone determination in expired air
NASA Astrophysics Data System (ADS)
Baranov, Vitaly V.
2001-05-01
Diseases and changes in the way of life change the concentration and composition of the expired air. Our adaptable gas analyzer is intended for the selective analysis of expired air and can be adapted for the solution of current diagnostic and analytical tasks by the user (a physician or a patient). Having analyzed the existing trends in the development of noninvasive diagnostics we have chosen the method of noninvasive acetone detection in expired air, where the acetone concentration correlates with blood and urine glucose concentrations. The appearance of acetone in expired air is indicative of disorders that may be caused not only by diabetes but also be wrong diet, incorrect sportsmen training etc. To control the disorders one should know the acetone concentration in the human body. This knowledge allows one to judge upon the state of the patient, choose a correct diet that will not cause damage to the patient's health, determine sportsmen training efficiency and results and solve the artificial pancreas problem. Our device provide highly accurate analysis, rapid diagnostics and authentic acetone quantification in the patient's body at any time aimed at prediction of the patient's state and assessing the efficiency of the therapy used. Clinical implementation of the device will improve the health and save lives of many thousands of diabetes sufferers.
A hierarchical fuzzy rule-based approach to aphasia diagnosis.
Akbarzadeh-T, Mohammad-R; Moshtagh-Khorasani, Majid
2007-10-01
Aphasia diagnosis is a particularly challenging medical diagnostic task due to the linguistic uncertainty and vagueness, inconsistencies in the definition of aphasic syndromes, large number of measurements with imprecision, natural diversity and subjectivity in test objects as well as in opinions of experts who diagnose the disease. To efficiently address this diagnostic process, a hierarchical fuzzy rule-based structure is proposed here that considers the effect of different features of aphasia by statistical analysis in its construction. This approach can be efficient for diagnosis of aphasia and possibly other medical diagnostic applications due to its fuzzy and hierarchical reasoning construction. Initially, the symptoms of the disease which each consists of different features are analyzed statistically. The measured statistical parameters from the training set are then used to define membership functions and the fuzzy rules. The resulting two-layered fuzzy rule-based system is then compared with a back propagating feed-forward neural network for diagnosis of four Aphasia types: Anomic, Broca, Global and Wernicke. In order to reduce the number of required inputs, the technique is applied and compared on both comprehensive and spontaneous speech tests. Statistical t-test analysis confirms that the proposed approach uses fewer Aphasia features while also presenting a significant improvement in terms of accuracy.
Rapid, absolute calibration of x-ray filters employed by laser-produced plasma diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, G. V.; Beiersdorfer, P.; Emig, J.
2008-10-15
The Electron Beam Ion Trap (EBIT) facility at the Lawrence Livermore National Laboratory is being used to absolutely calibrate the transmission efficiency of x-ray filters employed by diodes and spectrometers used to diagnose laser-produced plasmas. EBIT emits strong, discrete monoenergetic lines at appropriately chosen x-ray energies. X rays are detected using the high resolution EBIT Calorimeter Spectrometer (ECS), developed for LLNL at the NASA/Goddard Space Flight Center. X-ray filter transmission efficiency is determined by dividing the x-ray counts detected when the filter is in the line of sight by those detected when out of the line of sight. Verification ofmore » filter thickness can be completed in only a few hours, and absolute efficiencies can be calibrated in a single day over a broad range from about 0.1 to 15 keV. The EBIT calibration lab has been used to field diagnostics (e.g., the OZSPEC instrument) with fully calibrated x-ray filters at the OMEGA laser. Extensions to use the capability for calibrating filter transmission for the DANTE instrument on the National Ignition Facility are discussed.« less
NASA Astrophysics Data System (ADS)
Ponomarenko, Sergei A.; Surin, Nikolay M.; Borshchev, Oleg V.; Luponosov, Yuriy N.; Akimov, Dmitry Y.; Alexandrov, Ivan S.; Burenkov, Alexander A.; Kovalenko, Alexey G.; Stekhanov, Viktor N.; Kleymyuk, Elena A.; Gritsenko, Oleg T.; Cherkaev, Georgiy V.; Kechek'yan, Alexander S.; Serenko, Olga A.; Muzafarov, Aziz M.
2014-10-01
Organic luminophores are widely used in various optoelectronic devices, which serve for photonics, nuclear and particle physics, quantum electronics, medical diagnostics and many other fields of science and technology. Improving their spectral-luminescent characteristics for particular technical requirements of the devices is a challenging task. Here we show a new concept to universal solution of this problem by creation of nanostructured organosilicon luminophores (NOLs), which are a particular type of dendritic molecular antennas. They combine the best properties of organic luminophores and inorganic quantum dots: high absorption cross-section, excellent photoluminescence quantum yield, fast luminescence decay time and good processability. A NOL consists of two types of covalently bonded via silicon atoms organic luminophores with efficient Förster energy transfer between them. Using NOLs in plastic scintillators, widely utilized for radiation detection and in elementary particles discoveries, led to a breakthrough in their efficiency, which combines both high light output and fast decay time. Moreover, for the first time plastic scintillators, which emit light in the desired wavelength region ranging from 370 to 700 nm, have been created. We anticipate further applications of NOLs as working elements of pulsed dye lasers in photonics, optoelectronics and as fluorescent labels in biology and medical diagnostics.
Llama medicine. Physical examination, restraint and handling.
Fowler, M
1989-03-01
Llamas are generally docile, easily handled domestic animals. Special chutes have been designed for safe, efficient restraint for examination and diagnostic procedures, most of which are commonly performed on other species. Anatomic differences make some of these procedures unique to the llama.
The cobas® 6800/8800 System: a new era of automation in molecular diagnostics.
Cobb, Bryan; Simon, Christian O; Stramer, Susan L; Body, Barbara; Mitchell, P Shawn; Reisch, Natasa; Stevens, Wendy; Carmona, Sergio; Katz, Louis; Will, Stephen; Liesenfeld, Oliver
2017-02-01
Molecular diagnostics is a key component of laboratory medicine. Here, the authors review key triggers of ever-increasing automation in nucleic acid amplification testing (NAAT) with a focus on specific automated Polymerase Chain Reaction (PCR) testing and platforms such as the recently launched cobas® 6800 and cobas® 8800 Systems. The benefits of such automation for different stakeholders including patients, clinicians, laboratory personnel, hospital administrators, payers, and manufacturers are described. Areas Covered: The authors describe how molecular diagnostics has achieved total laboratory automation over time, rivaling clinical chemistry to significantly improve testing efficiency. Finally, the authors discuss how advances in automation decrease the development time for new tests enabling clinicians to more readily provide test results. Expert Commentary: The advancements described enable complete diagnostic solutions whereby specific test results can be combined with relevant patient data sets to allow healthcare providers to deliver comprehensive clinical recommendations in multiple fields ranging from infectious disease to outbreak management and blood safety solutions.
Singha, Harisankar; Malik, Praveen; Goyal, Sachin K; Khurana, Sandip K; Mukhopadhyay, Chiranjay; Eshwara, Vandana K; Singh, Raj K
2014-01-01
To express truncated TssB protein of Burkholderia mallei and to evaluate its diagnostic efficacy for serological detection of glanders among equines. In an attempt to develop recombinant protein based enzyme-linked immunosorbent assay (ELISA), N-terminal 200 amino acid sequences of B. mallei TssB protein-a type 6 secretory effector protein--were expressed in prokaryotic expression system. Diagnostic potential of recombinant TssB protein was evaluated in indirect ELISA using a panel of glanders positive (n = 49), negative (n = 30), and field serum samples (n = 1811). Cross-reactivity of the assay was assessed with equine disease control serum and human melioidosis positive serum. In comparison to CFT, diagnostic sensitivity and specificity of ELISA were 99.7% and 100%, respectively. The indirect ELISA method using the truncated TssB offered safer and more rapid and efficient means of serodiagnosis of glanders in equines. These data highlight the use of TssB as potential diagnostic antigen for serological diagnosis of glanders.
Diagnostic decision-making and strategies to improve diagnosis.
Thammasitboon, Satid; Cutrer, William B
2013-10-01
A significant portion of diagnostic errors arises through cognitive errors resulting from inadequate knowledge, faulty data gathering, and/or faulty verification. Experts estimate that 75% of diagnostic failures can be attributed to clinician diagnostic thinking failure. The cognitive processes that underlie diagnostic thinking of clinicians are complex and intriguing, and it is imperative that clinicians acquire explicit appreciation and application of different cognitive approaches to make decisions better. A dual-process model that unifies many theories of decision-making has emerged as a promising template for understanding how clinicians think and judge efficiently in a diagnostic reasoning process. The identification and implementation of strategies for decreasing or preventing such diagnostic errors has become a growing area of interest and research. Suggested strategies to decrease diagnostic error incidence include increasing clinician's clinical expertise and avoiding inherent cognitive errors to make decisions better. Implementing Interventions focused solely on avoiding errors may work effectively for patient safety issues such as medication errors. Addressing cognitive errors, however, requires equal effort on expanding the individual clinician's expertise. Providing cognitive support to clinicians for robust diagnostic decision-making serves as the final strategic target for decreasing diagnostic errors. Clinical guidelines and algorithms offer another method for streamlining decision-making and decreasing likelihood of cognitive diagnostic errors. Addressing cognitive processing errors is undeniably the most challenging task in reducing diagnostic errors. While many suggested approaches exist, they are mostly based on theories and sciences in cognitive psychology, decision-making, and education. The proposed interventions are primarily suggestions and very few of them have been tested in the actual practice settings. Collaborative research effort is required to effectively address cognitive processing errors. Researchers in various areas, including patient safety/quality improvement, decision-making, and problem solving, must work together to make medical diagnosis more reliable. © 2013 Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Honeyman-Buck, Janice C.; Huda, Walter; Palmer, Carole K.; Frost, Meryll M.; Moser, Robert; Staab, Edward V.
1995-04-01
A cost effectiveness study on the feasibility of using computed radiography (CR) instead of screen-film methods for portable radiographs indicates that we could only justify CR if film were eliminated. Before purchasing CR equipment, we needed to evaluate the use of softcopy to replace film for routine clinical use. The evaluation had to cover image quality, human factors, and efficiency measures. Screen-film radiographs were digitized and used to simulate CR in two studies. The first study evaluated the quality of digitized images and the workstation user interface. Twenty-one radiographs were selected at random from scopes in the radiology department, were digitized, and transferred to a megascan workstation. Five radiologists were asked to assess the quality of the images and the ease of operation of the workstation while an observer recorded their comments and scores. The second study evaluated the feasibility of using the workstation in a clinical environment. Four radiologists read adult and pediatric portable images in film and softcopy format. Reports were evaluated for differences and timing statistics were kept. The results of the first study indicate that image quality may be acceptable for diagnostic purposes and suggests some changes in the user interface. Newborn infant images were the least acceptable in softcopy, largely due to magnification artifacts introduced when viewing very small images. The evaluation was based on a digitizer as a simulator for a CR unit and the digitizer did not exhibit the same resolution characteristics as CR. Films that were unacceptable from the digitizer are expected to be acceptable with CR. The results of the second study indicated that the high resolution diagnostic workstation could be used in a clinical setting, and that the diagnostic readings were not significantly different between film and softcopy displays. The results also indicated that, depending on the radiologist and the type of images, more time was required to read from the workstation and that the increased time was spent using window/level and magnification/roam functions. This preliminary study suggests that the high resolution workstation developed at the University of Florida has adequate quality and functionality to be used for diagnostic interpretation of portable radiographs if given high resolution images. However, further investigation is indicated before we eliminate film in a CR environment.
Jousset, Alexandre; Lara, Enrique; Nikolausz, Marcell; Harms, Hauke; Chatzinotas, Antonis
2010-02-01
Ciliates (or Ciliophora) are ubiquitous organisms which can be widely used as bioindicators in ecosystems exposed to anthropogenic and industrial influences. The evaluation of the environmental impact on soil ciliate communities with methods relying on morphology-based identification may be hampered by the large number of samples usually required for a statistically supported, reliable conclusion. Cultivation-independent molecular-biological diagnostic tools are a promising alternative to greatly simplify and accelerate such studies. In this present work a ciliate-specific fingerprint method based on the amplification of a phylogenetic marker gene (i.e. the 18S ribosomal RNA gene) with subsequent analysis by denaturing gradient gel electrophoresis (DGGE) was developed and used to monitor community shifts in a polycyclic aromatic hydrocarbon (PAH) polluted soil. The semi-nested approach generated ciliate-specific amplification products from all soil samples and allowed to distinguish community profiles from a PAH-polluted and a non-polluted control soil. Subsequent sequence analysis of excised bands provided evidence that polluted soil samples are dominated by organisms belonging to the class Colpodea. The general DGGE approach presented in this study might thus in principle serve as a fast and reproducible diagnostic tool, complementing and facilitating future ecological and ecotoxicological monitoring of ciliates in polluted habitats. Copyright 2009 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Xiaohui; Couwenhoven, Mary E.; Foos, David H.; Doran, James; Yankelevitz, David F.; Henschke, Claudia I.
2008-03-01
An image-processing method has been developed to improve the visibility of tube and catheter features in portable chest x-ray (CXR) images captured in the intensive care unit (ICU). The image-processing method is based on a multi-frequency approach, wherein the input image is decomposed into different spatial frequency bands, and those bands that contain the tube and catheter signals are individually enhanced by nonlinear boosting functions. Using a random sampling strategy, 50 cases were retrospectively selected for the study from a large database of portable CXR images that had been collected from multiple institutions over a two-year period. All images used in the study were captured using photo-stimulable, storage phosphor computed radiography (CR) systems. Each image was processed two ways. The images were processed with default image processing parameters such as those used in clinical settings (control). The 50 images were then separately processed using the new tube and catheter enhancement algorithm (test). Three board-certified radiologists participated in a reader study to assess differences in both detection-confidence performance and diagnostic efficiency between the control and test images. Images were evaluated on a diagnostic-quality, 3-megapixel monochrome monitor. Two scenarios were studied: the baseline scenario, representative of today's workflow (a single-control image presented with the window/level adjustments enabled) vs. the test scenario (a control/test image pair presented with a toggle enabled and the window/level settings disabled). The radiologists were asked to read the images in each scenario as they normally would for clinical diagnosis. Trend analysis indicates that the test scenario offers improved reading efficiency while providing as good or better detection capability compared to the baseline scenario.
Zielińska-Bliźniewska, Hanna; Sułkowski, Wiesław J; Pietkiewicz, Piotr; Miłoński, Jarosław; Mazurek, Agnieszka; Olszewski, Jurek
2012-06-01
The aim of this study was to compare the parameters of vocal acoustic and vocal efficiency analyses in medical students and academic teachers with use of the IRIS and DiagnoScope Specialist software and to evaluate their usefulness in prevention and certification of occupational disease. The study group comprised 40 women, including students and employees of the Military Medical Faculty, Medical University of Łodź. After informed consent had been obtained from the participant women, the primary medical history was taken, videolaryngoscopic and stroboscopic examinations were performed and diagnostic vocal acoustic analysis was carried out with the use of the IRIS and Diagno-Scope Specialist software. Based on the results of the performed measurements, the statistical analysis evidenced the compatibility between two software programs, IRIS and DiagnoScope Specialist, with the only exception of the F4 formant. The mean values of vocal acoustic parameters in medical students and academic teachers, obtained by means of the IRIS software, can be used as standards for the female population not yet developed by the producer. When using the DiagnoScope Specialist software, some mean values were higher and some lower than the standards specified by the producer. The study evidenced the compatibility between two measurement software programs, IRIS and DiagnoScope Specialist, except for the F4 formant. It should be noted that the later has advantage over the former since the standard values of vocal acoustic parameters have been worked out by the producer. Moreover, they only slightly departed from the values obtained in our study and may be useful in diagnostics of occupational voice disorders.
Fortune, Brad; Zhang, Xian; Hood, Donald C; Demirel, Shaban; Patterson, Emily; Jamil, Annisa; Mansberger, Steven L; Cioffi, George A; Johnson, Chris A
2008-01-01
To evaluate the effect on diagnostic performance of reducing multifocal visual-evoked potential (mfVEP) recording duration from 16 to 8 minutes per eye. Both eyes of 185 individuals with high-risk ocular hypertension or early glaucoma were studied. Two 8-minute mfVEP recordings were obtained for each eye in an ABBA order using VERIS. The first recording for each eye was compared against single run (1-Run) mfVEP normative data; the average of both recordings for each eye was compared against 2-Run normative data. Visual fields (VFs) were obtained by standard automated perimetry (SAP) within 22.3+/-27.0 days of the mfVEP. Stereo disc photographs and Heidelberg Retina Tomograph images were obtained together, within 24.8+/-50.4 days of the mfVEP and 33.1+/-62.9 days of SAP. Masked experts graded disc photographs as either glaucomatous optic neuropathy or normal. The overall Moorfields Regression Analysis result from the Heidelberg Retina Tomograph was used as a separate diagnostic classification. Thus, 4 diagnostic standards were applied in total, 2 based on optic disc structure alone and 2 others based on disc structure and SAP. Agreement between the 1-Run and 2-Run mfVEP was 90%. Diagnostic performance of the 1-Run mfVEP was similar to that of the 2-Run mfVEP for all 4 diagnostic standards. Sensitivity was slightly higher for the 2-Run mfVEP, whereas specificity was slightly higher for the 1-Run mfVEP. If higher sensitivity is sought, the 2-Run mfVEP will provide better discrimination between groups of eyes with relatively high signal-to-noise ratio (eg, early glaucoma or high-risk suspects). But if higher specificity is a more important goal, the 1-Run mfVEP provides adequate sensitivity and requires only half the test time. Considered alongside prior studies, the present results suggest that the 1-Run mfVEP is an efficient way to confirm (or refute) the extent of VF loss in patients with moderate or advanced glaucoma, particularly in those with unreliable VFs, including malingering or other "functional" forms of VF loss.
NASA Astrophysics Data System (ADS)
Lu, Huijie; Peng, Zhangli
2017-11-01
We developed a high-efficiency multiscale modeling method to predict the stress and deformation of cells during the interactions with their microenvironments in microcirculation and microfluidics, including red blood cells (RBCs) and circulating tumor cells (CTCs). There are more than 1 billion people in the world suffering from RBC diseases. The mechanical properties of RBCs are changed in these diseases due to molecular structure alternations, which is not only important for understanding the disease pathology but also provides an opportunity for diagnostics. On the other hand, the mechanical properties of cancer cells are also altered compared to healthy cells. This can lead to acquired ability to cross the narrow capillary networks and endothelial gaps, which is crucial for metastasis, the leading cause of cancer mortality. Therefore, it is important to predict the deformation and stress of RBCs and CTCs in microcirculations. We develop a high-efficiency multiscale model of cell-fluid interaction. We pass the information from our molecular scale models to the cell scale to study the effect of molecular mutations. Using our high-efficiency boundary element methods of fluids, we will be able to run 3D simulations using a single CPU within several hours, which will enable us to run extensive parametric studies and optimization.
Maeda, Masaharu; Ueda, Yukiko; Nagai, Masato; Fujii, Senta; Oe, Misari
2016-09-01
The Great East Japan Earthquake and in particular, the Fukushima Daiichi Nuclear Power Plant accident, have had a serious psychological impact on not only residents, but also relief workers in Fukushima. Although public employees work in highly stressful situations and play a very important role in long-term relief, their psychiatric features have yet to be clarified. The two aims of this study were to identify the current prevalence rate of depression and post-traumatic stress disorder among public employees working in the disaster area using diagnostic interviews, and to speculate on the psychosocial factors affecting their mental condition. We conducted diagnostic interviews and self-administered questionnaires with 168 public employees working in two coastal towns in Fukushima. Results showed that the current prevalence of depression among public employees is as high as 17.9%, in contrast to the relatively low prevalence of post-traumatic stress disorder (4.8%). Based on the results of self-administered questionnaires and interview contents, frequent exposure to strong complaints or anger from residents and role conflicts were considered the cause of the high prevalence of depression. The present study reveals the serious mental status of public employees working in Fukushima and sheds light on the urgent need to establish an efficient care network to provide adequate psychiatric intervention. © 2016 The Authors. Psychiatry and Clinical Neurosciences © 2016 Japanese Society of Psychiatry and Neurology.
Blood culture-negative endocarditis
Fournier, Pierre-Edouard; Gouriet, Frédérique; Casalta, Jean-Paul; Lepidi, Hubert; Chaudet, Hervé; Thuny, Franck; Collart, Frédéric; Habib, Gilbert; Raoult, Didier
2017-01-01
Abstract Blood culture-negative endocarditis (BCNE) may represent up to 70% of all endocarditis cases, depending on series. From 2001 to 2009, we implemented in our laboratory a multimodal diagnostic strategy for BCNE that included systematized testing of blood, and when available, valvular biopsy specimens using serological, broad range molecular, and histopathological assays. A causative microorganism was identified in 62.7% of patients. In this study from January 2010 to December 2015, in an effort to increase the number of identified causative microorganisms, we prospectively added to our diagnostic protocol specific real-time (RT) polymerase chain reaction (PCR) assays targeting various endocarditis agents, and applied them to all patients with BCNE admitted to the 4 public hospitals in Marseille, France. A total of 283 patients with BCNE were included in the study. Of these, 177 were classified as having definite endocarditis. Using our new multimodal diagnostic strategy, we identified an etiology in 138 patients (78.0% of cases). Of these, 3 were not infective (2.2%) and 1 was diagnosed as having Mycobacterium bovis BCG endocarditis. By adding specific PCR assays from blood and valvular biopsies, which exhibited a significantly greater sensitivity (P < 10−2) than other methods, causative agents, mostly enterococci, streptococci, and zoonotic microorganisms, were identified in an additional 27 patients (14 from valves only, 11 from blood only, and 2 from both). Finally, in another 107 patients, a pathogen was detected using serology in 37, valve culture in 8, broad spectrum PCR from valvular biopsies and blood in 19 and 2, respectively, immunohistochemistry from valves in 3, and a combination of several assays in 38. By adding specific RT-PCR assays to our systematic PCR testing of patients with BCNE, we increased the diagnostic efficiency by 24.3%, mostly by detecting enterococci and streptococci that had not been detected by other diagnostic methods, but also agents requiring specific management such as Mycoplasma hominis and Tropheryma whipplei. PMID:29381916
Das, Debjit; Pratihar, Sanjay; Roy, Sujit
2013-03-15
An efficient Michael addition reaction of differently substituted enones with carbon, sulfur, oxygen, and nitrogen nucleophiles has been achieved by a new heterobimetallic "Pd-Sn" catalyst system. The nature of the catalytically relevant species and their interactions with the enone moiety has been examined by spectroscopy. The effect of ligand and the coordination mode of enone with "Pd-Sn" heterobimetallic system have been investigated by kinetics and DFT studies. A straightforward application of this methodology is shown in the synthesis of 1,4-oxathiepane core.
The Application of Advanced Diagnostics to the Study of Non-Equilibrium Air Plasmas
2002-09-01
26. The 10-, 100-, and 1000-µs pulses monotonically increase with N2 dilution, and the shapes agree with the calculation of Garscadden and Nagpal ...efficiency of H2 in a steady-state H2–N2 gas-mixture discharge has been measured by Nagpal et al.,24 and their analysis of the energy balance showed that...Bletzinger, J. Appl. Phys. 82, 4772 (1997). 49 23. A. Garscadden and R. Nagpal , Plasma Sources Sci. Technol. 4, 268 (1995). 24. R. Nagpal , B. N
WATERSHED CLASSIFICATION AS A DIAGNOSTIC TOOL FOR CONSOLIDATED ASSESSMENT AND LISTING PROGRAMS
With over 40,000 TMDLs scheduled for development, the states, tribes, and EPA Regions need efficient streamlined approaches for watershed level inventory, monitoring, condition assessment, diagnosis of impairment, and prioritization of watersheds for restoration and future load r...
40 CFR 86.1870-12 - CO2 credits for qualifying full-size pickup trucks.
Code of Federal Regulations, 2013 CFR
2013-07-01
... broadcast battery pack voltage via an on-board diagnostics parameter ID channel. (1) Full size pickup trucks... conditioning leakage and/or efficiency credits as determined in §§ 86.1867 and 6.1868. Pickup trucks earning...
Schmidt-Hieltjes, Yvonne; Elshof, Clemens; Roovers, Lian; Ruinemans-Koerts, Janneke
2016-05-01
The aim of our study was to analyse whether the κ/λ free light chain ratio reference range for screening for Bence Jones proteinuria should be dependent on the estimated glomerular filtration rate (eGFR). The serum κ/λ free light chain ratio, eGFR, serum M-protein and Bence Jones protein were measured in 544 patients for whom Bence Jones protein analysis was ordered. In the population of patients without Bence Jones proteinuria or a M-protein (n = 402), there is no gradual increase in κ/λ free light chain ratio with diminishing eGFR. The κ/λ free light chain ratio in this group was 0.56-1.86 (95% interval). With this diagnostic reference range of the κ/λ ratio, 105 of the 110 patients with Bence Jones protein could be identified correctly. Only five patients with Bence Jones proteinuria (<0.17 g/L) were missed, without diagnostic or therapeutic consequences. In 36 patients (6.6%), an abnormal κ/λ free light chain ratio was measured without the presence of Bence Jones proteinuria. A κ/λ free light chain ratio in serum can be used safely and efficiently to select urine samples which should be analysed for Bence Jones proteinuria with an electrophoresis/immunofixation technique. Using this diagnostic reference range, the number of urine samples which should be analysed by electrophoresis/immunofixation could be reduced by 74%. The diagnostic reference interval can be determined best in a group of patients for whom Bence Jones analysis is indicated. For calculation of this reference range, the eGFR value does not need to be taken into account. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik
2016-11-01
To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.
Yudkowsky, Rachel; Otaki, Junji; Lowenstein, Tali; Riddle, Janet; Nishigori, Hiroshi; Bordage, Georges
2009-08-01
Diagnostic accuracy is maximised by having clinical signs and diagnostic hypotheses in mind during the physical examination (PE). This diagnostic reasoning approach contrasts with the rote, hypothesis-free screening PE learned by many medical students. A hypothesis-driven PE (HDPE) learning and assessment procedure was developed to provide targeted practice and assessment in anticipating, eliciting and interpreting critical aspects of the PE in the context of diagnostic challenges. This study was designed to obtain initial content validity evidence, performance and reliability estimates, and impact data for the HDPE procedure. Nineteen clinical scenarios were developed, covering 160 PE manoeuvres. A total of 66 Year 3 medical students prepared for and encountered three clinical scenarios during required formative assessments. For each case, students listed anticipated positive PE findings for two plausible diagnoses before examining the patient; examined a standardised patient (SP) simulating one of the diagnoses; received immediate feedback from the SP, and documented their findings and working diagnosis. The same students later encountered some of the scenarios during their Year 4 clinical skills examination. On average, Year 3 students anticipated 65% of the positive findings, correctly performed 88% of the PE manoeuvres and documented 61% of the findings. Year 4 students anticipated and elicited fewer findings overall, but achieved proportionally more discriminating findings, thereby more efficiently achieving a diagnostic accuracy equivalent to that of students in Year 3. Year 4 students performed better on cases on which they had received feedback as Year 3 students. Twelve cases would provide a reliability of 0.80, based on discriminating checklist items only. The HDPE provided medical students with a thoughtful, deliberate approach to learning and assessing PE skills in a valid and reliable manner.
Nazerian, Peiman; Volpicelli, Giovanni; Gigli, Chiara; Becattini, Cecilia; Sferrazza Papa, Giuseppe Francesco; Grifoni, Stefano; Vanni, Simone
2017-03-01
Lung and venous ultrasound are bedside diagnostic tools increasingly used in the early diagnostic approach of suspected pulmonary embolism (PE). However, the possibility of improving the conventional prediction rule for PE by integrating ultrasound has never been investigated. We performed lung and venous ultrasound in consecutive patients suspected of PE in four emergency departments. Conventional Wells score (Ws) was adjudicated by the attending physician, and ultrasound was performed by one of 20 investigators. Signs of deep venous thrombosis (DVT) at venous ultrasound and signs of pulmonary infarcts or alternative diagnoses at lung ultrasound were considered to recalculate two items of the Ws: signs and symptoms of DVT and alternative diagnosis less likely than PE. The diagnostic performances of the ultrasound-enhanced Ws (USWs) and Ws were then compared after confirmation of the final diagnosis. A total of 446 patients were studied. PE was confirmed in 125 patients (28%). USWs performed significantly better than Ws, with a sensitivity of 69.6% versus 57.6% and a specificity of 88.2% versus 68.2%. In combination with D-dimer, USWs showed an optimal failure rate (0.8%) and a significantly superior efficiency than Ws (32.3% vs. 27.2%). A strategy based on lung and venous ultrasound combined with D-dimer would allow to avoid CT pulmonary angiography in 50.5% of patients with suspected PE, compared to 27.2% when the rule without ultrasound is applied. A pretest risk stratification enhanced by ultrasound of lung and venous performs better than Ws in the early diagnostic process of PE. © 2016 by the Society for Academic Emergency Medicine.
Jiang, Z F; Wang, M; Xu, J L
2018-02-01
Thymidine kinase 1 (TK1) is a tumor biomarker in human malignancies. The purpose of this study was to evaluate the diagnostic efficiency of this marker for lung cancer using the combined analysis of carcinoembryonic antigen (CEA), cytokeratin-19 fragment (CYFRA21-1), neuron specific enolase (NSE) and TK1. From 2013 to 2014, 147 patients with lung cancer and 228 patients with lung benign diseases who were admitted to our hospital were reviewed. Peripheral blood samples were collected for the detection of TK1, CEA, CYFRA21-1 and NSE. The diagnostic value of each marker was analyzed using receiver operating characteristic (ROC) curves and logistic regression equations. The serum levels of TK1, CEA, CYFRA21-1 and NSE were significantly higher than those in patients with lung benign diseases (all P<0.05). The TK1 concentration was dependent on TNM stage (P=0.005). The ROC curve analyses showed that the diagnostic value of TK1 combined with CEA, CYFRA21-1 and NSE in lung cancer was significantly higher than that of each biomarker alone (all P<0.0001). In addition, TK1 combined with CEA, CYFRA21-1, or NSE could also improve the diagnosis of the squamous cell carcinoma, adenocarcinoma and small cell lung cancer subtypes, respectively. The combined detection of TK1 and the other three markers significantly improved the diagnosis of lung cancer. Furthermore, the detection of TK1 combined with that of CYFRA21-1, CEA or NSE increased the diagnostic value of TK1 for lung squamous cell carcinoma, adenocarcinoma and SCLC, respectively. Copyright © 2017 Elsevier Inc. All rights reserved.
2012-01-01
Background Resource-limited tropical countries are home to numerous infectious pathogens of both human and zoonotic origin. A capability for early detection to allow rapid outbreak containment and prevent spread to non-endemic regions is severely impaired by inadequate diagnostic laboratory capacity, the absence of a “cold chain” and the lack of highly trained personnel. Building up detection capacity in these countries by direct replication of the systems existing in developed countries is not a feasible approach and instead requires “leapfrogging” to the deployment of the newest diagnostic systems that do not have the infrastructure requirements of systems used in developed countries. Methods A laboratory for molecular diagnostics of infectious agents was established in Bo, Sierra Leone with a hybrid solar/diesel/battery system to ensure stable power supply and a satellite modem to enable efficient communication. An array of room temperature stabilization and refrigeration technologies for reliable transport and storage of reagents and biological samples were also tested to ensure sustainable laboratory supplies for diagnostic assays. Results The laboratory demonstrated its operational proficiency by conducting an investigation of a suspected avian influenza outbreak at a commercial poultry farm at Bo using broad range resequencing microarrays and real time RT-PCR. The results of the investigation excluded influenza viruses as a possible cause of the outbreak and indicated a link between the outbreak and the presence of Klebsiella pneumoniae. Conclusions This study demonstrated that by application of a carefully selected set of technologies and sufficient personnel training, it is feasible to deploy and effectively use a broad-range infectious pathogen detection technology in a severely resource-limited setting. PMID:22759725
Rodríguez-González, Alejandro; Torres-Niño, Javier; Valencia-Garcia, Rafael; Mayer, Miguel A; Alor-Hernandez, Giner
2013-09-01
This paper proposes a new methodology for assessing the efficiency of medical diagnostic systems and clinical decision support systems by using the feedback/opinions of medical experts. The methodology behind this work is based on a comparison between the expert feedback that has helped solve different clinical cases and the expert system that has evaluated these same cases. Once the results are returned, an arbitration process is carried out in order to ensure the correctness of the results provided by both methods. Once this process has been completed, the results are analyzed using Precision, Recall, Accuracy, Specificity and Matthews Correlation Coefficient (MCC) (PRAS-M) metrics. When the methodology is applied, the results obtained from a real diagnostic system allow researchers to establish the accuracy of the system based on objective facts. The methodology returns enough information to analyze the system's behavior for each disease in the knowledge base or across the entire knowledge base. It also returns data on the efficiency of the different assessors involved in the evaluation process, analyzing their behavior in the diagnostic process. The proposed work facilitates the evaluation of medical diagnostic systems, having a reliable process based on objective facts. The methodology presented in this research makes it possible to identify the main characteristics that define a medical diagnostic system and their values, allowing for system improvement. A good example of the results provided by the application of the methodology is shown in this paper. A diagnosis system was evaluated by means of this methodology, yielding positive results (statistically significant) when comparing the system with the assessors that participated in the evaluation process of the system through metrics such as recall (+27.54%) and MCC (+32.19%). These results demonstrate the real applicability of the methodology used. Copyright © 2013 Elsevier Ltd. All rights reserved.
Parametric Thermal and Flow Analysis of ITER Diagnostic Shield Module
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khodak, A.; Zhai, Y.; Wang, W.
As part of the diagnostic port plug assembly, the ITER Diagnostic Shield Module (DSM) is designed to provide mechanical support and the plasma shielding while allowing access to plasma diagnostics. Thermal and hydraulic analysis of the DSM was performed using a conjugate heat transfer approach, in which heat transfer was resolved in both solid and liquid parts, and simultaneously, fluid dynamics analysis was performed only in the liquid part. ITER Diagnostic First Wall (DFW) and cooling tubing were also included in the analysis. This allowed direct modeling of the interface between DSM and DFW, and also direct assessment of themore » coolant flow distribution between the parts of DSM and DFW to ensure DSM design meets the DFW cooling requirements. Design of the DSM included voids filled with Boron Carbide pellets, allowing weight reduction while keeping shielding capability of the DSM. These voids were modeled as a continuous solid with smeared material properties using analytical relation for thermal conductivity. Results of the analysis lead to design modifications improving heat transfer efficiency of the DSM. Furthermore, the effect of design modifications on thermal performance as well as effect of Boron Carbide will be presented.« less
Parametric Thermal and Flow Analysis of ITER Diagnostic Shield Module
Khodak, A.; Zhai, Y.; Wang, W.; ...
2017-06-19
As part of the diagnostic port plug assembly, the ITER Diagnostic Shield Module (DSM) is designed to provide mechanical support and the plasma shielding while allowing access to plasma diagnostics. Thermal and hydraulic analysis of the DSM was performed using a conjugate heat transfer approach, in which heat transfer was resolved in both solid and liquid parts, and simultaneously, fluid dynamics analysis was performed only in the liquid part. ITER Diagnostic First Wall (DFW) and cooling tubing were also included in the analysis. This allowed direct modeling of the interface between DSM and DFW, and also direct assessment of themore » coolant flow distribution between the parts of DSM and DFW to ensure DSM design meets the DFW cooling requirements. Design of the DSM included voids filled with Boron Carbide pellets, allowing weight reduction while keeping shielding capability of the DSM. These voids were modeled as a continuous solid with smeared material properties using analytical relation for thermal conductivity. Results of the analysis lead to design modifications improving heat transfer efficiency of the DSM. Furthermore, the effect of design modifications on thermal performance as well as effect of Boron Carbide will be presented.« less
Targeted Re-Sequencing Emulsion PCR Panel for Myopathies: Results in 94 Cases.
Punetha, Jaya; Kesari, Akanchha; Uapinyoying, Prech; Giri, Mamta; Clarke, Nigel F; Waddell, Leigh B; North, Kathryn N; Ghaoui, Roula; O'Grady, Gina L; Oates, Emily C; Sandaradura, Sarah A; Bönnemann, Carsten G; Donkervoort, Sandra; Plotz, Paul H; Smith, Edward C; Tesi-Rocha, Carolina; Bertorini, Tulio E; Tarnopolsky, Mark A; Reitter, Bernd; Hausmanowa-Petrusewicz, Irena; Hoffman, Eric P
2016-05-27
Molecular diagnostics in the genetic myopathies often requires testing of the largest and most complex transcript units in the human genome (DMD, TTN, NEB). Iteratively targeting single genes for sequencing has traditionally entailed high costs and long turnaround times. Exome sequencing has begun to supplant single targeted genes, but there are concerns regarding coverage and needed depth of the very large and complex genes that frequently cause myopathies. To evaluate efficiency of next-generation sequencing technologies to provide molecular diagnostics for patients with previously undiagnosed myopathies. We tested a targeted re-sequencing approach, using a 45 gene emulsion PCR myopathy panel, with subsequent sequencing on the Illumina platform in 94 undiagnosed patients. We compared the targeted re-sequencing approach to exome sequencing for 10 of these patients studied. We detected likely pathogenic mutations in 33 out of 94 patients with a molecular diagnostic rate of approximately 35%. The remaining patients showed variants of unknown significance (35/94 patients) or no mutations detected in the 45 genes tested (26/94 patients). Mutation detection rates for targeted re-sequencing vs. whole exome were similar in both methods; however exome sequencing showed better distribution of reads and fewer exon dropouts. Given that costs of highly parallel re-sequencing and whole exome sequencing are similar, and that exome sequencing now takes considerably less laboratory processing time than targeted re-sequencing, we recommend exome sequencing as the standard approach for molecular diagnostics of myopathies.
Cabon, J; Louboutin, L; Castric, J; Bergmann, S; Bovo, G; Matras, M; Haenen, O; Olesen, N J; Morin, T
2017-05-01
Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of a serious infective, notifiable disease affecting common carp and varieties. In survivors, infection is generally characterized by a subclinical latency phase with restricted viral replication. The CyHV-3 genome is difficult to detect in such carrier fish that represent a potential source of dissemination if viral reactivation occurs. In this study, the analytical and diagnostic performance of an alternative serum neutralization (SN) method based on the detection of CyHV-3-specific antibodies was assessed using 151 serum or plasma samples from healthy and naturally or experimentally CyHV-3-infected carp. French CyHV-3 isolate 07/108b was neutralized efficiently by sera from carp infected with European, American and Taiwanese CyHV-3 isolates, but no neutralization was observed using sera specific to other aquatic herpesviruses. Diagnostic sensitivity, diagnostic specificity and repeatability of 95.9%, 99.0% and 99.3%, respectively, were obtained, as well as a compliance rate of 89.9% in reproducibility testing. Neutralizing antibodies were steadily detected in infected carp subjected to restrictive or permissive temperature variations over more than 25 months post-infection. The results suggest that this non-lethal diagnostic test could be used in the future to improve the epidemiological surveillance and control of CyHV-3 disease. © 2016 John Wiley & Sons Ltd.
The Diagnostic Accuracy of Cytology for the Diagnosis of Hepatobiliary and Pancreatic Cancers.
Al-Hajeili, Marwan; Alqassas, Maryam; Alomran, Astabraq; Batarfi, Bashaer; Basunaid, Bashaer; Alshail, Reem; Alaydarous, Shahad; Bokhary, Rana; Mosli, Mahmoud
2018-06-13
Although cytology testing is considered a valuable method to diagnose tumors that are difficult to access such as hepato-biliary-pancreatic (HBP) malignancies, its diagnostic accuracy remains unclear. We therefore aimed to investigate the diagnostic accuracy of cytology testing for HBP tumors. We performed a retrospective study of all cytology samples that were used to confirm radiologically detected HBP tumors between 2002 and 2016. The cytology techniques used in our center included fine needle aspiration (FNA), brush cytology, and aspiration of bile. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated in comparison to histological confirmation. From a total of 133 medical records, we calculated an overall sensitivity of 76%, specificity of 74%, a negative likelihood ratio of 0.30, and a positive likelihood ratio of 2.9. Cytology was more accurate in diagnosing lesions of the liver (sensitivity 79%, specificity 57%) and biliary tree (sensitivity 100%, specificity 50%) compared to pancreatic (sensitivity 60%, specificity 83%) and gallbladder lesions (sensitivity 50%, specificity 85%). Cytology was more accurate in detecting primary cancers (sensitivity 77%, specificity 73%) when compared to metastatic cancers (sensitivity 73%, specificity 100%). FNA was the most frequently used cytological technique to diagnose HBP lesions (sensitivity 78.8%). Cytological testing is efficient in diagnosing HBP cancers, especially for hepatobiliary tumors. Given its relative simplicity, cost-effectiveness, and paucity of alternative diagnostic methods, cytology should still be considered as a first-line tool for diagnosing HBP malignancies. © 2018 S. Karger AG, Basel.
Lefèvre, G; Fayet, J-M; Graïne, H; Berny, C; Maupas-Schwalm, F; Capolaghi, B; Morin, C
2007-01-01
The diagnostic performance of heart-Fatty Acid Binding Protein (h-FABP) (semi-quantitative CardioDetect test) and cardiac troponin I (TnIc) blood assays were compared in one hundred patients presenting with suspicion of acute coronary syndrome. Final patient diagnosis was "acute myocardial infarction" in 36 cases, "non ST myocardial infarction" in 25 cases and "non ischemic pathologies" in 39 cases. h-FABP results were positive in 26 patients, negative in 57 patients and ambiguous in 17 patients, the latter corresponding to the final diagnosis of "acute myocardial infarction" in 5 cases, "non ST myocardial infarction" in 2 cases and "non ischemic pathologies " in 10 cases. At admission, h-FABP and TnIc exhibiteda sensitivity of 54% an 66%, respectively and a specificity of 86% and 95%, respectively. Positive and negative predictive values were 81% and 64% for h-FABP, respectively and 92% and 75% for cTnI, respectively. h-FABP and cTnI demonstrated a similar diagnostic efficiency if admission delay is less than 4 hours after onset of chest pain (area under ROC curve TnIc = 0.767 +/- 0.091 ; area under ROC curve h-FABP = 0.622 +/- 0.109 ; p = 0.144). On the contrary, cTnI assay demonstrated a better efficiency than h-FABP (p< 0.005) for patients admitted in a delay of 4 to 12 hours after the onset of chest pain. If chosen cTnI cut-off corresponded to the recent consensus definition used for monitoring acute coronary syndrome patients, h-FABP semi-quantitative assay realized within central laboratory did not demonstrated a better diagnostic efficiency than cTnI.
De Maio, Peter; White, Lawrence M; Bleakney, Robert; Menezes, Ravi J; Theodoropoulos, John
2014-07-01
To evaluate the diagnostic performance of viewing magnetic resonance (MR) images on a handheld mobile device compared with a conventional radiology workstation for the diagnosis of intra-articular knee pathology. Prospective comparison study. Tertiary care center. Fifty consecutive subjects who had MR imaging of the knee followed by knee arthroscopy were prospectively evaluated. Two musculoskeletal radiologists independently reviewed each MR study using 2 different viewers: the OsiriX DICOM viewer software on an Apple iPhone 3GS device and eFilm Workstation software on a conventional picture archiving and communications system workstation. Sensitivity and specificity of the iPhone and workstation interpretations was performed using knee arthroscopy as the reference standard. Intraobserver concordance and agreement between the iPhone and workstation interpretations were determined. There was no statistically significant difference between the 2 devices for each paired comparison of diagnostic performance. For the iPhone interpretations, sensitivity ranged from 77% (13 of 17) for the lateral meniscus to 100% (17 of 17) for the anterior cruciate ligament. Specificity ranged from 74% (14 of 19) for cartilage to 100% (50 of 50) for the posterior cruciate ligament. There was a very high level of interobserver and intraobserver agreement between devices and readers. The iPhone reads took longer than the corresponding workstation reads, with a significant mean difference between the iPhone and workstation reads of 3.98 minutes (P < 0.001). The diagnostic performance of interpreting MR images on a handheld mobile device for the assessment of intra-articular knee pathology is similar to that of a conventional radiology workstation, however, requires a longer viewing time. Timely and accurate interpretation of complex medical images using mobile device solutions could result in new workflow efficiencies and ultimately improve patient care.
Popiela, Tadeusz J; Urbanik, Andrzej; Słowik, Agnieszka
2010-01-01
To lower the number of complications of acute cerebral ischemic stroke and to reduce the time of rehabilitation in these patients it is necessary to induce treatment within the first 3 hours of the onset of the stroke. Early intervention however, is possible only in cases with the confirm localized ischemic focus visualized in one of the diagnostic imaging methods. The most widespread is CT, hovewer the first symptoms of ischemic stroke can be seen not beforel2 hours of the onset. The study evaluated the effectiveness of early diagnostics of ischemic stroke using perfusion CT (pCT) with subsequent intravenous or intra-arterial thrombolysis. The patients with ischemic stroke confirmed by pCT and qualified to thrombolysis in the first 3 hours of the onset of the stroke were randomly selected to intravenous or intra-arterial thrmobolysis. Those, who were 3 to 6 hours of the onset of the stroke were qualified to intra-arterial thrombolysis. A study group consisted of 377 patients hospitalized due to ischemic stroke. Of these pCT was performed in 76 cases, intravenous thrombolysis in 4 and intra-arterial thrombolysis in 2. Clinical condition substantially improved in 3 patients. Obtained results indicate the necessity to introduce pCT to the routine diagnostics of the acute ischemic stroke. A small number of patients eligible for thrombolysis does not allow to compare the effectiveness of intra-arterial and intravenous thrombolysis, however the project allowed to work out the efficient system of diagnostics and treatment of the acute ischemic stroke in the area of Krakow based on the standards used in the European countries.
Svraka-Latifovic, S; Bouter, S; Naus, H; Bakker, L J; Timmerman, C P; Dorigo-Zetsma, J W
2014-11-01
Detection of intestinal protozoa by PCR methods has been described as being sensitive and specific, and as improving the diagnostic yield. Here we present the outcome of the transition from microscopy to molecular screening for detection of a select group of intestinal protozoa in faeces in our laboratory. Introduction of molecular screening for intestinal protozoa resulted in higher sensitivity, reduced hands-on-time, reduced time-to-results, leading to improved diagnostic efficiency. © 2014 The Authors Clinical Microbiology and Infection © 2014 European Society of Clinical Microbiology and Infectious Diseases.
Rossi, Mari; El-Khechen, Dima; Black, Mary Helen; Farwell Hagman, Kelly D; Tang, Sha; Powis, Zöe
2017-05-01
Exome sequencing has recently been proved to be a successful diagnostic method for complex neurodevelopmental disorders. However, the diagnostic yield of exome sequencing for autism spectrum disorders has not been extensively evaluated in large cohorts to date. We performed diagnostic exome sequencing in a cohort of 163 individuals with autism spectrum disorder (66.3%) or autistic features (33.7%). The diagnostic yield observed in patients in our cohort was 25.8% (42 of 163) for positive or likely positive findings in characterized disease genes, while a candidate genetic etiology was reported for an additional 3.3% (4 of 120) of patients. Among the positive findings in the patients with autism spectrum disorder or autistic features, 61.9% were the result of de novo mutations. Patients presenting with psychiatric conditions or ataxia or paraplegia in addition to autism spectrum disorder or autistic features were significantly more likely to receive positive results compared with patients without these clinical features (95.6% vs 27.1%, P < 0.0001; 83.3% vs 21.2%, P < 0.0001, respectively). The majority of the positive findings were in recently identified autism spectrum disorder genes, supporting the importance of diagnostic exome sequencing for patients with autism spectrum disorder or autistic features as the causative genes might evade traditional sequential or panel testing. These results suggest that diagnostic exome sequencing would be an efficient primary diagnostic method for patients with autism spectrum disorders or autistic features. Moreover, our data may aid clinicians to better determine which subset of patients with autism spectrum disorder with additional clinical features would benefit the most from diagnostic exome sequencing. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Ju, Feng; Lee, Hyo Kyung; Yu, Xinhua; Faris, Nicholas R; Rugless, Fedoria; Jiang, Shan; Li, Jingshan; Osarogiagbon, Raymond U
2017-12-01
The process of lung cancer care from initial lesion detection to treatment is complex, involving multiple steps, each introducing the potential for substantial delays. Identifying the steps with the greatest delays enables a focused effort to improve the timeliness of care-delivery, without sacrificing quality. We retrospectively reviewed clinical events from initial detection, through histologic diagnosis, radiologic and invasive staging, and medical clearance, to surgery for all patients who had an attempted resection of a suspected lung cancer in a community healthcare system. We used a computer process modeling approach to evaluate delays in care delivery, in order to identify potential 'bottlenecks' in waiting time, the reduction of which could produce greater care efficiency. We also conducted 'what-if' analyses to predict the relative impact of simulated changes in the care delivery process to determine the most efficient pathways to surgery. The waiting time between radiologic lesion detection and diagnostic biopsy, and the waiting time from radiologic staging to surgery were the two most critical bottlenecks impeding efficient care delivery (more than 3 times larger compared to reducing other waiting times). Additionally, instituting surgical consultation prior to cardiac consultation for medical clearance and decreasing the waiting time between CT scans and diagnostic biopsies, were potentially the most impactful measures to reduce care delays before surgery. Rigorous computer simulation modeling, using clinical data, can provide useful information to identify areas for improving the efficiency of care delivery by process engineering, for patients who receive surgery for lung cancer.
Lessons learned from additional research analyses of unsolved clinical exome cases.
Eldomery, Mohammad K; Coban-Akdemir, Zeynep; Harel, Tamar; Rosenfeld, Jill A; Gambin, Tomasz; Stray-Pedersen, Asbjørg; Küry, Sébastien; Mercier, Sandra; Lessel, Davor; Denecke, Jonas; Wiszniewski, Wojciech; Penney, Samantha; Liu, Pengfei; Bi, Weimin; Lalani, Seema R; Schaaf, Christian P; Wangler, Michael F; Bacino, Carlos A; Lewis, Richard Alan; Potocki, Lorraine; Graham, Brett H; Belmont, John W; Scaglia, Fernando; Orange, Jordan S; Jhangiani, Shalini N; Chiang, Theodore; Doddapaneni, Harsha; Hu, Jianhong; Muzny, Donna M; Xia, Fan; Beaudet, Arthur L; Boerwinkle, Eric; Eng, Christine M; Plon, Sharon E; Sutton, V Reid; Gibbs, Richard A; Posey, Jennifer E; Yang, Yaping; Lupski, James R
2017-03-21
Given the rarity of most single-gene Mendelian disorders, concerted efforts of data exchange between clinical and scientific communities are critical to optimize molecular diagnosis and novel disease gene discovery. We designed and implemented protocols for the study of cases for which a plausible molecular diagnosis was not achieved in a clinical genomics diagnostic laboratory (i.e. unsolved clinical exomes). Such cases were recruited to a research laboratory for further analyses, in order to potentially: (1) accelerate novel disease gene discovery; (2) increase the molecular diagnostic yield of whole exome sequencing (WES); and (3) gain insight into the genetic mechanisms of disease. Pilot project data included 74 families, consisting mostly of parent-offspring trios. Analyses performed on a research basis employed both WES from additional family members and complementary bioinformatics approaches and protocols. Analysis of all possible modes of Mendelian inheritance, focusing on both single nucleotide variants (SNV) and copy number variant (CNV) alleles, yielded a likely contributory variant in 36% (27/74) of cases. If one includes candidate genes with variants identified within a single family, a potential contributory variant was identified in a total of ~51% (38/74) of cases enrolled in this pilot study. The molecular diagnosis was achieved in 30/63 trios (47.6%). Besides this, the analysis workflow yielded evidence for pathogenic variants in disease-associated genes in 4/6 singleton cases (66.6%), 1/1 multiplex family involving three affected siblings, and 3/4 (75%) quartet families. Both the analytical pipeline and the collaborative efforts between the diagnostic and research laboratories provided insights that allowed recent disease gene discoveries (PURA, TANGO2, EMC1, GNB5, ATAD3A, and MIPEP) and increased the number of novel genes, defined in this study as genes identified in more than one family (DHX30 and EBF3). An efficient genomics pipeline in which clinical sequencing in a diagnostic laboratory is followed by the detailed reanalysis of unsolved cases in a research environment, supplemented with WES data from additional family members, and subject to adjuvant bioinformatics analyses including relaxed variant filtering parameters in informatics pipelines, can enhance the molecular diagnostic yield and provide mechanistic insights into Mendelian disorders. Implementing these approaches requires collaborative clinical molecular diagnostic and research efforts.
Tang, Yin-Liang; Chiu, Chien-Yu; Lin, Chun-Yu; Huang, Chung-Hao; Chen, Yen-Hsu; Destura, Raul V.; Chao, Day-Yu; Wu, Han-Chung
2015-01-01
Dengue virus (DENV) infection is currently at pandemic levels, with populations in tropical and subtropical regions at greatest risk of infection. Early diagnosis and management remain the cornerstone for good clinical outcomes, thus efficient and accurate diagnostic technology in the early stage of the disease is urgently needed. Serotype-specific monoclonal antibodies (mAbs) against the DENV1 nonstructural protein 1 (NS1), DA12-4, DA13-2, and DA15-3, which were recently generated using the hybridoma technique, are suitable for use in diagnostic platforms. Immunofluorescence assay (IFA), enzyme-linked immunosorbent assay (ELISA) and Western blot analysis further confirmed the serotype specificity of these three monoclonal antibodies. The ELISA-based diagnostic platform was established using the combination of two highly sensitive mAbs (DA15-3 and DB20-6). The same combination was also used for the flow cytometry-based diagnostic platform. We report here the detection limits of flow cytometry-based and ELISA-based diagnostic platforms using these mAbs to be 0.1 and 1 ng/mL, respectively. The collected clinical patient serum samples were also assayed by these two serotyping diagnostic platforms. The sensitivity and specificity for detecting NS1 protein of DENV1 are 90% and 96%, respectively. The accuracy of our platform for testing clinical samples is more advanced than that of the two commercial NS1 diagnostic platforms. In conclusion, our platforms are suitable for the early detection of NS1 protein in DENV1 infected patients. PMID:26610481
Poste, George; Carbone, David P.; Parkinson, David R.; Verweij, Jaap; Hewitt, Stephen; Jessup, J. Milburn
2012-01-01
Molecular diagnostics are increasingly important in clinical research to stratify or identify molecularly profiled patient cohorts for targeted therapies, to modify the dose of a therapeutic, or to assess early response to therapy or monitor patients. Molecular diagnostics can also be used to identify pharmocogenetic risk of adverse drug reactions. The articles of this CCR Focus section on Molecular Diagnosis describe the development and use of markers for medical decision-making in the cancer patient. They define the sources of preanalytic variability to minimize as well as the regulatory and financial challenges in diagnostic development and integration into clinical practice. They also outline an NCI program to assist diagnostic development. Molecular diagnostic clinical tests require rigor in their development and clinical validation with sufficient sensitivity, specificity and validity that is comparable to that used for development of therapeutics. These diagnostics must be offered at a realistic cost that reflects both their clinical value and the costs associated with their development. When genome sequencing technologies move into the clinic, they must be integrated with and traceable to current technology because they may identify more efficient and accurate approaches to drug development. In addition, regulators may define progressive drug approval for companion diagnostics that requires further evidence regarding efficacy and safety before full approval. A way to accomplish this is to emphasize Phase IV post-marketing hypothesis driven clinical trials with biological characterization that permits accurate definition of the association of low prevalence gene alterations with toxicity or response in large cohorts. PMID:22422403
Poste, George; Carbone, David P; Parkinson, David R; Verweij, Jaap; Hewitt, Stephen M; Jessup, J Milburn
2012-03-15
Molecular diagnostics are becoming increasingly important in clinical research to stratify or identify molecularly profiled patient cohorts for targeted therapies, to modify the dose of a therapeutic, and to assess early response to therapy or monitor patients. Molecular diagnostics can also be used to identify the pharmacogenetic risk of adverse drug reactions. The articles in this CCR Focus section on molecular diagnosis describe the development and use of markers to guide medical decisions regarding cancer patients. They define sources of preanalytic variability that need to be minimized, as well as the regulatory and financial challenges involved in developing diagnostics and integrating them into clinical practice. They also outline a National Cancer Institute program to assist diagnostic development. Molecular diagnostic clinical tests require rigor in their development and clinical validation, with sensitivity, specificity, and validity comparable to those required for the development of therapeutics. These diagnostics must be offered at a realistic cost that reflects both their clinical value and the costs associated with their development. When genome-sequencing technologies move into the clinic, they must be integrated with and traceable to current technology because they may identify more efficient and accurate approaches to drug development. In addition, regulators may define progressive drug approval for companion diagnostics that requires further evidence regarding efficacy and safety before full approval can be achieved. One way to accomplish this is to emphasize phase IV postmarketing, hypothesis-driven clinical trials with biological characterization that would permit an accurate definition of the association of low-prevalence gene alterations with toxicity or response in large cohorts.
Validation of two screening instruments for PTSD in Dutch substance use disorder inpatients.
Kok, Tim; de Haan, Hein A; van der Velden, Helena J W; van der Meer, Margreet; Najavits, Lisa M; de Jong, Cor A J
2013-03-01
Posttraumatic stress disorder (PTSD) is highly prevalent in substance use disorder (SUD) populations. Because resources for extensive and thorough diagnostic assessment are often limited, reliable screening instruments for PTSD are needed. The aim of the current study was to test two short PTSD measures for diagnostic efficiency in predicting PTSD compared to the Clinician-Administered PTSD Scale (CAPS). The sample consisted of 197 SUD patients receiving residential substance use treatment who completed questionnaires regarding substance use and trauma-related symptoms, all abstinent from substance for 4weeks. The PTSD section of the Mini International Neuropsychiatric Interview plus (MINIplus) and the Self-Report Inventory for PTSD (SRIP) are compared to the CAPS. Results showed low sensitivity (.58) and high specificity (.91) for the PTSD section of the MINIplus. The SRIP showed high sensitivity (.80) and moderately high specificity (.73) at a cut-off score of 48. The prevalence of PTSD as measured with the CAPS was 25.4% current and 46.2% lifetime. Results indicate that the MINIplus, a short clinical interview, has insufficient quality as a screener for PTSD. The SRIP, however, is a reliable instrument in detecting PTSD in a SUD inpatient population in The Netherlands. Screening for PTSD is time efficient and increases detection of PTSD in SUD treatment settings. Copyright © 2012 Elsevier Ltd. All rights reserved.
Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics
NASA Astrophysics Data System (ADS)
Yu, Tao; Cai, Weiwei; Liu, Yingzheng
2018-04-01
Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.
Rapid tomographic reconstruction based on machine learning for time-resolved combustion diagnostics.
Yu, Tao; Cai, Weiwei; Liu, Yingzheng
2018-04-01
Optical tomography has attracted surged research efforts recently due to the progress in both the imaging concepts and the sensor and laser technologies. The high spatial and temporal resolutions achievable by these methods provide unprecedented opportunity for diagnosis of complicated turbulent combustion. However, due to the high data throughput and the inefficiency of the prevailing iterative methods, the tomographic reconstructions which are typically conducted off-line are computationally formidable. In this work, we propose an efficient inversion method based on a machine learning algorithm, which can extract useful information from the previous reconstructions and build efficient neural networks to serve as a surrogate model to rapidly predict the reconstructions. Extreme learning machine is cited here as an example for demonstrative purpose simply due to its ease of implementation, fast learning speed, and good generalization performance. Extensive numerical studies were performed, and the results show that the new method can dramatically reduce the computational time compared with the classical iterative methods. This technique is expected to be an alternative to existing methods when sufficient training data are available. Although this work is discussed under the context of tomographic absorption spectroscopy, we expect it to be useful also to other high speed tomographic modalities such as volumetric laser-induced fluorescence and tomographic laser-induced incandescence which have been demonstrated for combustion diagnostics.
Design Study of an X-ray Crystal Spectrometer for the HANBIT Mirror Machine
NASA Astrophysics Data System (ADS)
Lee, S. G.; Hwang, S. M.; Bitter, M. L.
1997-11-01
X-ray crystal spectroscopy is expected to play a major role for the diagnostics of the reactor-like plasmas produced in future large tokamaks, such as KSTAR and ITER. However, it is also desirable to extend the observable spectral range to longer wavelengths (7-15 dotA), which is of interest for the diagnostics of plasmas with much lower electron densities (10^11-10^12 cm-3) and electron temperatures (100 - 200 eV) in other magnetic-confinement experiments, such as the HANBIT mirror machine. The construction of crystal spectrometers for this wavelength range and these plasma conditions is challenging because of the low X-ray emissivity and the fact that the low-energy X-rays are strongly attenuated by even very thin foils or windows. New types of detectors other than the presently used multi-wire proportional counters are therefore needed to obtain a high detection efficiency. In this paper, we present a design study for a vacuum spectrometer with a CCD array detector and detailed estimates of the instrument performance for the observation of spectra from O, Ne and Al ions.
The injection of microorganisms into an atmospheric pressure rf-driven microplasma
NASA Astrophysics Data System (ADS)
Maguire, P. D.; Mahony, C. M. O.; Diver, D.; Mariotti, D.; Bennet, E.; Potts, H.; McDowell, D. A.
2013-09-01
The introduction of living organisms, such as bacteria, into atmospheric pressure microplasmas offers a unique means to study certain physical mechanisms in individual microorganisms and also help understand the impact of macroscopic entities and liquid droplets on plasma characteristics. We present the characterization of an RF-APD operating at 13.56 MHz and containing microorganisms in liquid droplets emitted from a nebulizer, with the spray entrained in a gas flow by a gas shroud and passed into the plasma source. We report successful microorganism injection and transmission through the plasma with stable plasma operation of at least one hour. Diagnostics include RF electrical characterization, optical emission spectrometry and electrostatic deflection to investigate microorganism charging. A close-coupled Impedans Octiv VI probe indicates source efficiencies of 10 to 15%. The introduction of the droplets/microorganisms results in increased plasma conductivity and reduced capacitance, due to their impact on electron density and temperature. An electrical model will be presented based on diagnostic data and deflection studies with input from simulations of charged aerosol diffusion and evaporation. Engineering and Physical Sciences Research Council EP/K006088, EP/K006142.
Video integrated measurement system. [Diagnostic display devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spector, B.; Eilbert, L.; Finando, S.
A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides anmore » innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.« less
The Citadel cannot hold: technologies go outside the hospital, patients and doctors too.
Stoeckle, J D
1995-01-01
Use of the acute hospital has markedly decreased over the past four decades for various reasons: the decentralization of diagnostic treatment technologies to out-of-hospital sites; the clinical substitutions of quick diagnostic testing of the ambulatory patient for the longer diagnostic testing of the hospitalized patient; the diminished use of hospital bed rest and the expanded use of exercise for treatment; the corporate organization of hospital work that emphasizes efficiency; and the group practice organization of generalists and specialists that avoids hospital use for the diagnosis of complex disorders in ambulatory patients. A smaller domain for hospital bed care and renewed attention to chronic disease and prevention in the community diminish the hold of the acute hospital on care. The evolution of more collaborative, decentralized arrangements promises to be a positive development for community care.
Instrumentation for noninvasive express-diagnostics bacteriophages and viruses by optical method
NASA Astrophysics Data System (ADS)
Moguilnaia, Tatiana A.; Andreev, Gleb I.; Agibalov, Andrey A.; Botikov, Andrey G.; Kosenkov, Evgeniy; Saguitova, Elena
2004-03-01
The theoretical and the experimental researches of spectra of absent-minded radiation in medium containing viruses were carried out. The information on spectra luminescence 31 viruses was written down.The new method the express - analysis of viruses in organism of the man was developed. It shall be mentioned that the proposed method of express diagnostics allows detection of infection agent in the organism several hours after infection. It makes it suitable for high efficient testing in blood services for detection and rejection of potential donors infected with such viruses as hepatitis, herpes, Epstein-Barre, cytomegalovirus, and immunodeficiency. Methods of serum diagnostics used for that purpose can detect antibodies to virus only 1-3 months after the person has been infected. The device for the express analysis of 31 viruses of the man was created.
Efficient screening for COPD using three steps: a cross-sectional study in Mexico City.
Franco-Marina, Francisco; Fernandez-Plata, Rosario; Torre-Bouscoulet, Luis; García-Sancho, Cecilia; Sanchez-Gallen, Elisa; Martinez, David; Perez-Padilla, Rogelio
2014-05-20
Underdiagnosis of chronic obstructive pulmonary disease (COPD) in primary care can be improved by a more efficient screening strategy. To evaluate a three-step method of screening for COPD consisting of an initial short questionnaire followed by measurement of forced expiratory volume in 1s/forced expiratory volume in 6s (FEV1/FEV6) using an inexpensive pocket spirometer in those with high risk, and diagnostic quality spirometry in those with a low FEV1/FEV6. We analysed two related Mexico City cross-sectional samples. The 2003 Mexico City PLATINO survey (n=542) was used to develop a short questionnaire to determine the risk of COPD and a 2010 survey (n=737) additionally used a pocket spirometer. The discriminatory power of the two instruments was assessed with receiver operator characteristic (ROC) curves using three COPD definitions. The developed COPD scale included two variables from a simple questionnaire and, in ROC analysis, an area under the curve (AUC) between 0.64 and 0.77 was found to detect COPD. The pocket spirometer had an AUC between 0.85 and 0.88 to detect COPD. Using the COPD scale as a first screening step excluded 35-48% of the total population from further testing at the cost of not detecting 8-18% of those with COPD. Using the pocket spirometer and sending those with a FEV1/FEV6<0.80 for diagnostic quality spirometry is very efficient, and substantially improved the positive predictive value at the cost of not detecting one-third of COPD cases. A three-step screening strategy for COPD substantially reduces the need for spirometry testing when only a COPD scale is used for screening.
Cancer Detection Using Neural Computing Methodology
NASA Technical Reports Server (NTRS)
Toomarian, Nikzad; Kohen, Hamid S.; Bearman, Gregory H.; Seligson, David B.
2001-01-01
This paper describes a novel learning methodology used to analyze bio-materials. The premise of this research is to help pathologists quickly identify anomalous cells in a cost efficient method. Skilled pathologists must methodically, efficiently and carefully analyze manually histopathologic materials for the presence, amount and degree of malignancy and/or other disease states. The prolonged attention required to accomplish this task induces fatigue that may result in a higher rate of diagnostic errors. In addition, automated image analysis systems to date lack a sufficiently intelligent means of identifying even the most general regions of interest in tissue based studies and this shortfall greatly limits their utility. An intelligent data understanding system that could quickly and accurately identify diseased tissues and/or could choose regions of interest would be expected to increase the accuracy of diagnosis and usher in truly automated tissue based image analysis.
NASA Technical Reports Server (NTRS)
Musgrave, Jeffrey L.
1997-01-01
General aviation research is leading to major advances in internal combustion engine control systems for single-engine, single-pilot aircraft. These advances promise to increase engine performance and fuel efficiency while substantially reducing pilot workload and increasing flight safety. One such advance is a single-lever power control (SLPC) system, a welcome departure from older, less user-friendly, multilever engine control systems. The benefits of using single-lever power controls for general aviation aircraft are improved flight safety through advanced engine diagnostics, simplified powerplant operations, increased time between overhauls, and cost-effective technology (extends fuel burn and reduces overhaul costs). The single-lever concept has proven to be so effective in preliminary studies that general aviation manufacturers are making plans to retrofit current aircraft with the technology and are incorporating it in designs for future aircraft.
Diagnostics of the power oil-filled transformer equipment of thermal power plants
NASA Astrophysics Data System (ADS)
Eltyshev, D. K.; Khoroshev, N. I.
2016-08-01
Problems concerning improvement of the diagnostics efficiency of the electrical facilities and functioning of the generation and distribution systems through the examples of the power oil-filled transformers, as the responsible elements referring to the electrical part of thermal power plants (TPP), were considered. Research activity is based on the fuzzy logic system allowing working both with statistical and expert information presented in the form of knowledge accumulated during operation of the power oil-filled transformer facilities. The diagnostic algorithm for various types of transformers, with the use of the intellectual estimation model of its thermal state on the basis of the key diagnostic parameters and fuzzy inference hierarchy, was developed. Criteria for taking measures allowing preventing emergencies in the electric power systems were developed. The fuzzy hierarchical model for the state assessment of the power oil-filled transformers of 110 kV, possessing high degree of credibility and setting quite strict requirements to the limits of variables of the equipment diagnostic parameters, was developed. The most frequent defects of the transformer standard elements, related with the disturbance of the isolation properties and instrumentation operation, were revealed after model testing on the real object. Presented results may be used both for the express diagnostics of the transformers state without disconnection from the power line and for more detailed analysis of the defects causes on the basis of the advanced list of the diagnostic parameters; information on those parameters may be received only after complete or partial disconnection.
Preliminary Evaluation of a Diagnostic Tool for Prosthetics
2017-10-01
volume change. Processing algorithms for data from the activity monitors were modified to run more efficiently so that large datasets could be...left) and blade style prostheses (right). Figure 4: Ankle ActiGraph correct position demonstrated for a left leg below-knee amputee cylindrical
Workflow computing. Improving management and efficiency of pathology diagnostic services.
Buffone, G J; Moreau, D; Beck, J R
1996-04-01
Traditionally, information technology in health care has helped practitioners to collect, store, and present information and also to add a degree of automation to simple tasks (instrument interfaces supporting result entry, for example). Thus commercially available information systems do little to support the need to model, execute, monitor, coordinate, and revise the various complex clinical processes required to support health-care delivery. Workflow computing, which is already implemented and improving the efficiency of operations in several nonmedical industries, can address the need to manage complex clinical processes. Workflow computing not only provides a means to define and manage the events, roles, and information integral to health-care delivery but also supports the explicit implementation of policy or rules appropriate to the process. This article explains how workflow computing may be applied to health-care and the inherent advantages of the technology, and it defines workflow system requirements for use in health-care delivery with special reference to diagnostic pathology.
Zhao, B B; Yang, Z J; Wang, Q; Pan, Z M; Zhang, W; Li, D R; Li, L
2016-10-25
Objective: Establish and validation of combined detecting of CCL18, CXCL1, C1D, TM4SF1, FXR1, TIZ suspension array technology. Methods: (1)CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ protein were coupled with polyethylene microspheres. Biotinylated CCL18, CXCL1 polyclonal antibody and sheep anti-human IgG polyclonal antibody were prepared simultaneously. The best packaged concentrations of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigens were optimized. The best packaged concentrations of CCL18, CXCL1 polyclonal antibodys and C1D, TM4SF1, FXR1, TIZ sheep anti-human IgG polyclonal antibody were optimized to establish a stable detected suspension array.(2)Sixty patients confirmed by pathological examination with ovarian cancer(ovarian cancer group)which treated in Affiliated Tumor Hospital of Guangxi Medical University, 30 patients with ovarian benign tumor(benign group)and 30 cases of healthy women(control group)were chosen between September 2003 and December 2003. Suspension array technology and ELISA method were used to detect expression of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1 and TIZ IgG autoantibody contented in 3 groups of serum, then to compare the diagnostic efficiency and diagnostic accuracy of two methods(coefficient of variation between batch and batch). Results: (1)This research successfully established stable detecting system of CCL18, CXCL1, C1D, TM4SF1, FXR1 and TIZ IgG autoantibody. The best concentration of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigen package were 8, 8, 12, 8, 4 and 8 μg/ml; the best detection of CCL18, CXCL1 biotin polyclonal antibody and C1D, TM4SF1, FXR1, TIZ sheep anti-huamne IgG polyclonal antibody were respectively 4, 2, 2, 4, 4 and 2 μg/ml.(2)Suspension array technology and ELISA method were used to detect CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody of three groups in serum were similar( P >0.05).(3)The comparison of two methods in the diagnosis of efficiency: the diagnostic accuracy of two methods were 99.2%(119/120)and 94.2%(113/120), the difference was statistically significant( P =0.031). The sensitivity of the diagnosis of ovarian cancer of two methods were 100.0%(60/60)and 93.3%(56/60), specific degrees were 100.0%(59/59)and 93.4%(57/61), positive predictive value was 100.0%(60/60)and 93.3%(56/60), negative predictive value was 98.3%(59/60)and 95.0%(57/60), the difference was statistically significant( P <0.05).(4)The detected results of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody shown that the diagnostic accuracy of suspension array technology was superior to those of ELISA method(all P <0.05). Conclusion: The study has established the stable detection of suspension array technology, and the diagnostic efficiency and diagnostic accuracy was much better than that by ELISA.
A challenge for theranostics: is the optimal particle for therapy also optimal for diagnostics?
NASA Astrophysics Data System (ADS)
Dreifuss, Tamar; Betzer, Oshra; Shilo, Malka; Popovtzer, Aron; Motiei, Menachem; Popovtzer, Rachela
2015-09-01
Theranostics is defined as the combination of therapeutic and diagnostic capabilities in the same agent. Nanotechnology is emerging as an efficient platform for theranostics, since nanoparticle-based contrast agents are powerful tools for enhancing in vivo imaging, while therapeutic nanoparticles may overcome several limitations of conventional drug delivery systems. Theranostic nanoparticles have drawn particular interest in cancer treatment, as they offer significant advantages over both common imaging contrast agents and chemotherapeutic drugs. However, the development of platforms for theranostic applications raises critical questions; is the optimal particle for therapy also the optimal particle for diagnostics? Are the specific characteristics needed to optimize diagnostic imaging parallel to those required for treatment applications? This issue is examined in the present study, by investigating the effect of the gold nanoparticle (GNP) size on tumor uptake and tumor imaging. A series of anti-epidermal growth factor receptor conjugated GNPs of different sizes (diameter range: 20-120 nm) was synthesized, and then their uptake by human squamous cell carcinoma head and neck cancer cells, in vitro and in vivo, as well as their tumor visualization capabilities were evaluated using CT. The results showed that the size of the nanoparticle plays an instrumental role in determining its potential activity in vivo. Interestingly, we found that although the highest tumor uptake was obtained with 20 nm C225-GNPs, the highest contrast enhancement in the tumor was obtained with 50 nm C225-GNPs, thus leading to the conclusion that the optimal particle size for drug delivery is not necessarily optimal for imaging. These findings stress the importance of the investigation and design of optimal nanoparticles for theranostic applications.Theranostics is defined as the combination of therapeutic and diagnostic capabilities in the same agent. Nanotechnology is emerging as an efficient platform for theranostics, since nanoparticle-based contrast agents are powerful tools for enhancing in vivo imaging, while therapeutic nanoparticles may overcome several limitations of conventional drug delivery systems. Theranostic nanoparticles have drawn particular interest in cancer treatment, as they offer significant advantages over both common imaging contrast agents and chemotherapeutic drugs. However, the development of platforms for theranostic applications raises critical questions; is the optimal particle for therapy also the optimal particle for diagnostics? Are the specific characteristics needed to optimize diagnostic imaging parallel to those required for treatment applications? This issue is examined in the present study, by investigating the effect of the gold nanoparticle (GNP) size on tumor uptake and tumor imaging. A series of anti-epidermal growth factor receptor conjugated GNPs of different sizes (diameter range: 20-120 nm) was synthesized, and then their uptake by human squamous cell carcinoma head and neck cancer cells, in vitro and in vivo, as well as their tumor visualization capabilities were evaluated using CT. The results showed that the size of the nanoparticle plays an instrumental role in determining its potential activity in vivo. Interestingly, we found that although the highest tumor uptake was obtained with 20 nm C225-GNPs, the highest contrast enhancement in the tumor was obtained with 50 nm C225-GNPs, thus leading to the conclusion that the optimal particle size for drug delivery is not necessarily optimal for imaging. These findings stress the importance of the investigation and design of optimal nanoparticles for theranostic applications. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr03119b
Psychometric Evaluation of the PSQI in U.S. College Students
Dietch, Jessica R.; Taylor, Daniel J.; Sethi, Kevin; Kelly, Kimberly; Bramoweth, Adam D.; Roane, Brandy M.
2016-01-01
Study Objectives: Examine the psychometric properties of the PSQI in two U.S. college samples. Methods: Study I assessed convergent and divergent validity in 866 undergraduates who completed a sleep diary, PSQI, and other sleep and psychosocial measures. Study II assessed PSQI insomnia diagnostic accuracy in a separate sample of 147 healthy undergraduates with and without insomnia. Results: The PSQI global score had only moderate convergent validity with sleep diary sleep efficiency (prospective global measure of sleep continuity; r = 0.53), the Insomnia Severity Index (r = 0.63), and fatigue (r = 0.44). The PSQI global score demonstrated good divergent validity with measures of excessive daytime sleepiness (r = 0.18), circadian preference (r = −0.08), alcohol (r = 0.08) and marijuana (r = 0.05) abuse scales, and poor divergent validity with depression (r = 0.48), anxiety (r = 0.40), and perceived stress (r = 0.33). Examination of other analogous PSQI and sleep diary components showed low to moderate convergent validity: sleep latency (r = 0.70), wake after sleep onset (r = 0.37), sleep duration (r = 0.51), and sleep efficiency (r = −0.32). Diagnostic accuracy of the PSQI to detect insomnia was very high (area under the curve = 0.999). Sensitivity and specificity were maximized at a cutoff of 6. Conclusions: The PSQI demonstrated moderate convergent validity compared to measures of insomnia and fatigue and good divergent validity with measures of daytime sleepiness, circadian phase preference, and alcohol and marijuana use. The PSQI demonstrated considerable overlap with depression, anxiety, and perceived stress. Therefore, caution should be used with interpretation. Citation: Dietch JR, Taylor DJ, Sethi K, Kelly K, Bramoweth AD, Roane BM. Psychometric evaluation of the PSQI in U.S. college students. J Clin Sleep Med 2016;12(8):1121–1129. PMID:27166299
NASA Astrophysics Data System (ADS)
Borghesani, P.; Pennacchi, P.; Ricci, R.; Chatterton, S.
2013-10-01
Cyclostationary models for the diagnostic signals measured on faulty rotating machineries have proved to be successful in many laboratory tests and industrial applications. The squared envelope spectrum has been pointed out as the most efficient indicator for the assessment of second order cyclostationary symptoms of damages, which are typical, for instance, of rolling element bearing faults. In an attempt to foster the spread of rotating machinery diagnostics, the current trend in the field is to reach higher levels of automation of the condition monitoring systems. For this purpose, statistical tests for the presence of cyclostationarity have been proposed during the last years. The statistical thresholds proposed in the past for the identification of cyclostationary components have been obtained under the hypothesis of having a white noise signal when the component is healthy. This need, coupled with the non-white nature of the real signals implies the necessity of pre-whitening or filtering the signal in optimal narrow-bands, increasing the complexity of the algorithm and the risk of losing diagnostic information or introducing biases on the result. In this paper, the authors introduce an original analytical derivation of the statistical tests for cyclostationarity in the squared envelope spectrum, dropping the hypothesis of white noise from the beginning. The effect of first order and second order cyclostationary components on the distribution of the squared envelope spectrum will be quantified and the effectiveness of the newly proposed threshold verified, providing a sound theoretical basis and a practical starting point for efficient automated diagnostics of machine components such as rolling element bearings. The analytical results will be verified by means of numerical simulations and by using experimental vibration data of rolling element bearings.
Nazerian, Peiman; Morello, Fulvio; Vanni, Simone; Bono, Alessia; Castelli, Matteo; Forno, Daniela; Gigli, Chiara; Soardo, Flavia; Carbone, Federica; Lupia, Enrico; Grifoni, Stefano
2014-07-15
Acute aortic dissection (AD) represents a diagnostic conundrum. Validated algorithms are particularly needed to identify patients where AD could be ruled out without aortic imaging. We evaluated the diagnostic accuracy of a strategy combining the aortic dissection detection (ADD) risk score with D-dimer, a sensitive biomarker of AD. Patients from two clinical centers with suspected AD were prospectively enrolled in a registry, from January 2008 to March 2013. The ADD risk score was calculated by retrospective blinded chart review. For D-dimer, a cutoff of 500 ng/ml was applied. AD was diagnosed in 233 of 1035 (22.5%) patients. The ADD risk score was 0 in 322 (31.1%), 1 in 508 (49.1%) and >1 in 205 (19.8%) patients. The sensitivity and the failure rate of D-dimer were 100% and 0% in patients with ADD score 0, versus 97.5% (95% CI 91.4-99.6%) and 4.2% (95% CI 0.7-12.5%) in patients with ADD risk score >1. In patients with ADD risk score ≤ 1, the sensitivity and the failure rate of D-dimer were 98.7% (95% CI 95.3-99.8%) and 0.8% (95% CI 0.1-2.6%). The diagnostic efficiency of D-dimer in patients with ADD risk score 0 and ≤ 1 was 8.9% (95% CI 7.2-10.7%) and 23.6% (95% CI 21.1-26.2%) respectively. In a large cohort of patients with suspected AD, the presence of ADD risk score 0 or ≤ 1 combined with a negative D-dimer accurately and efficiently ruled out AD. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
INFLUENCE OF PEAT ON FENTON OXIDATION
A diagnostic probe was used to estimate the activity of Fenton-derived hydroxyl radicals (@OH), reaction kinetics, and oxidation efficiency in batch suspensions comprised of silica sand, crushed goethite ("-FeOOH) ore, peat, and H2O2 (0.13 mM). A simple method of kinetic analysi...
Jiang, Jing; Liu, Wanhua; Ye, Yuanyuan; Wang, Rui; Li, Fengfang; Peng, Chengyu
2014-06-17
To investigate the diagnostic efficiency of decline rate of signal intensity and apparent diffusion coefficient with different b values for differentiating benign and malignant breast lesions on diffusion-weighted 3.0 T magnetic resonance imaging. A total of 152 patients with 162 confirmed histopathologically breast lesions (85 malignant and 77 benign) underwent 3.0 T diffusion-weighted magnetic resonance imaging. Four b values (0, 400, 800 and 1 000 s/mm²) were used. The signal intensity and ADC values of breast lesions were measured respectively. The signal intensity decline rate (SIDR) and apparent diffusion coefficient decline rate (ADCDR) were calculated respectively. SIDR = (signal intensity of lesions with low b value-signal intensity of lesions with high b value)/signal intensity of lesions with low b value, ADCDR = (ADC value of lesions with low b value-ADC value of lesions with high b value) /ADC value of lesions with low b value. The independent sample t-test was employed for statistical analyses and the receiver operating characteristic (ROC) curve for evaluating the diagnosis efficiency of SIDR and ADCDR values. Significant differences were observed in SIDR between benign and malignant breast lesions with b values of 0-400, 400-800 and 800-1 000 s/mm². The sensitivities of SIDR for differentiating benign and malignant breast lesions were 61.2%, 68.2% and 67.1%, the specificities 74.0%, 85.7% and 67.5%, the diagnosis accordance rates 67.3%, 76.5% and 67.3%, the positive predictive values 72.2%, 84.1% and 69.5% and the negative predictive values 63.3%, 71.0% and 65.0% respectively. Significant differences were observed in ADCDR between benign and malignant breast lesions with b values of 400-800 s/mm² and 800-1 000 s/mm². The sensitivities of SDR for differentiating benign and malignant breast lesions were 80.0% and 65.9%, the specificities 72.7% and 65.0%, the diagnostic accordance rates 76.5% and 65.4%, the positive predictive values 76.4% and 67.5% and the negative predictive values 76.7% and 63.3% respectively. The decline rate of signal intensity and apparent diffusion coefficient with different b values may be used for differentiating benign and malignant breast lesions. And the diagnostic efficiency with b values of 400-800 s/mm² is optimal.
Yang, Tao; Sezer, Hayri; Celik, Ismail B.; ...
2015-06-02
In the present paper, a physics-based procedure combining experiments and multi-physics numerical simulations is developed for overall analysis of SOFCs operational diagnostics and performance predictions. In this procedure, essential information for the fuel cell is extracted first by utilizing empirical polarization analysis in conjunction with experiments and refined by multi-physics numerical simulations via simultaneous analysis and calibration of polarization curve and impedance behavior. The performance at different utilization cases and operating currents is also predicted to confirm the accuracy of the proposed model. It is demonstrated that, with the present electrochemical model, three air/fuel flow conditions are needed to producemore » a set of complete data for better understanding of the processes occurring within SOFCs. After calibration against button cell experiments, the methodology can be used to assess performance of planar cell without further calibration. The proposed methodology would accelerate the calibration process and improve the efficiency of design and diagnostics.« less
Páramo, José A.; Rodríguez JA, José A.; Orbe, Josune
2006-01-01
The clinical utility of a biomarker depends on its ability to identify high-risk individuals to optimally manage the patient. A new biomarker would be of clinical value if it is accurate and reliable, provides good sensitivity and specificity, and is available for widespread application. Data are accumulating on the potential clinical utility of integrating imaging technologies and circulating biomarkers for the identification of vulnerable (high-risk) cardiovascular patients. A multi-biomarker strategy consisting of markers of inflammation, hemostasis and thrombosis, proteolysis and oxidative stress, combined with new imaging modalities (optical coherence tomography, virtual histology plus IVUS, PET) can increase our ability to identify such thombosis-prone patients. In an ideal scenario, cardiovascular biomarkers and imaging combined will provide a better diagnostic tool to identify high-risk individuals and also more efficient methods for effective therapies to reduce such cardiovascular risk. However, additional studies are required in order to show that this approach can contribute to improved diagnostic and therapeutic of atherosclerotic disease. PMID:19690647
Páramo, José A; Rodríguez Ja, José A; Orbe, Josune
2007-02-07
The clinical utility of a biomarker depends on its ability to identify high-risk individuals to optimally manage the patient. A new biomarker would be of clinical value if it is accurate and reliable, provides good sensitivity and specificity, and is available for widespread application. Data are accumulating on the potential clinical utility of integrating imaging technologies and circulating biomarkers for the identification of vulnerable (high-risk) cardiovascular patients. A multi-biomarker strategy consisting of markers of inflammation, hemostasis and thrombosis, proteolysis and oxidative stress, combined with new imaging modalities (optical coherence tomography, virtual histology plus IVUS, PET) can increase our ability to identify such thombosis-prone patients. In an ideal scenario, cardiovascular biomarkers and imaging combined will provide a better diagnostic tool to identify high-risk individuals and also more efficient methods for effective therapies to reduce such cardiovascular risk. However, additional studies are required in order to show that this approach can contribute to improved diagnostic and therapeutic of atherosclerotic disease.
Oh, Hong-Choon; Toh, Hong-Guan; Giap Cheong, Eddy Seng
2011-11-01
Using the classical process improvement framework of Plan-Do-Study-Act (PDSA), the diagnostic radiology department of a tertiary hospital identified several patient cycle time reduction strategies. Experimentation of these strategies (which included procurement of new machines, hiring of new staff, redesign of queue system, etc.) through pilot scale implementation was impractical because it might incur substantial expenditure or be operationally disruptive. With this in mind, simulation modeling was used to test these strategies via performance of "what if" analyses. Using the output generated by the simulation model, the team was able to identify a cost-free cycle time reduction strategy, which subsequently led to a reduction of patient cycle time and achievement of a management-defined performance target. As healthcare professionals work continually to improve healthcare operational efficiency in response to rising healthcare costs and patient expectation, simulation modeling offers an effective scientific framework that can complement established process improvement framework like PDSA to realize healthcare process enhancement. © 2011 National Association for Healthcare Quality.
Bio-Fluid Dynamics in a Centimeter-Scale Diagnostics Incubator with Integrated Perfusion
NASA Astrophysics Data System (ADS)
Vukasinovic, J.; Cullen, D. K.; Glezer, A.; Laplaca, M. C.
2006-11-01
Growing demands for long-term incubation of biologically faithful, three-dimensional neuronal and other cultures during extended physiological studies require efficient perfusion platforms with functional vasculatures that mimic the in vivo condition in a thermally regulated environment. While thermostatically controlled incubation baths with capillary action perfusion are available, their use is confined to specific experimental conditions. The interstitial nutrient and gas delivery remains diffusion limited over the long term and cultures decay metabolically. To overcome these problems, we describe simple fabrication and experimental characterization of a compact, diagnostics incubator that allows in situ monitoring of culture activity with a superior control of critical biological functions using convectively enhanced heat and mass transport. To overcome intercellular diffusion barriers culture is exposed to a direct flow of media issuing from an array of micro-nozzles that are directed normal to the substrate upholding the culture, and further improved by 3-D convection induced by jet interactions and biased, peripheral perfusate extraction through an array of microchannels as demonstrated by microPIV measurements.
Characterization and Separation of Cancer Cells with a Wicking Fiber Device.
Tabbaa, Suzanne M; Sharp, Julia L; Burg, Karen J L
2017-12-01
Current cancer diagnostic methods lack the ability to quickly, simply, efficiently, and inexpensively screen cancer cells from a mixed population of cancer and normal cells. Methods based on biomarkers are unreliable due to complexity of cancer cells, plasticity of markers, and lack of common tumorigenic markers. Diagnostics are time intensive, require multiple tests, and provide limited information. In this study, we developed a novel wicking fiber device that separates cancer and normal cell types. To the best of our knowledge, no previous work has used vertical wicking of cells through fibers to identify and isolate cancer cells. The device separated mouse mammary tumor cells from a cellular mixture containing normal mouse mammary cells. Further investigation showed the device separated and isolated human cancer cells from a heterogeneous mixture of normal and cancerous human cells. We report a simple, inexpensive, and rapid technique that has potential to identify and isolate cancer cells from large volumes of liquid samples that can be translated to on-site clinic diagnosis.
Turki, Habibollah; Raeisi, Ahmad; Malekzadeh, Kianoosh; Ghanbarnejad, Amin; Zoghi, Samaneh; Yeryan, Masoud; Abedi Nejad, Masoumeh; Mohseni, Fatemeh; Shekari, Mohammad
2015-01-01
The aim of this study was to detect low parasite and asymptomatic malaria infections by means of three malaria diagnostic tests, in a low transmission region of Minab district, Hormozgan Province, southern Iran. Blood samples of 200 healthy volunteers from Bagh-e-Malek area were evaluated using microscopic, rapid diagnostic tests (RDT) and nested-PCR to inspect malaria parasite. The results showed no Plasmodium parasite in subjects by means of microscopy and RDT. However, 3 P. vivax positive samples (1.5%) were discovered by Nested-PCR while microscopy and RDT missed the cases. Microscopy as the gold standard method and RDT correctly identified 98.5% of cases, and molecular analysis is sensitive and reliable, especially in the detection of "asymptomatic" infections for active case surveillance. Regarding the existence of asymptomatic malaria in endemic area of Hormozgan, Iran, nested-PCR could be considered as a sensitive tool to interrupt malaria transmission in the country, beside the microscopic and RDT methods.
Use of IgY antibody to recombinant avian reovirus σC protein in the virus diagnostics.
Jung, K M; Bae, E H; Jung, Y T; Kim, J W
2014-01-01
Avian reovirus (ARV) is an important agent of several diseases causing considerable losses in poultry farming. An outer capsid protein (σC) of ARV, is known as a virus-cell attachment protein essential for virus infectivity. In this study, the σC gene of ARV was cloned and expressed in Escherichia coli. The expressed recombinant protein was used as immunogen for raising a specific IgY antibody in laying hens. At 14 weeks post immunization, the antibody titers in serum and egg yolk reached 302,000 and 355,000, respectively. The IgY antibody was capable to neutralize ARV in BHK-21 cells and it strongly reacted in ELISA with ARV but not with heterologous viruses. The IgY antibody detected ARV in field samples of infected animal tissues in dot blot assay. These results suggest that an efficient, economic and rapid diagnostics of ARV can be performed routinely using the IgY antibody against a recombinant ARV σC protein.
Diagnostic efficiency of amylase and type IV collagen in predicting chronic pancreatitis.
Das, Subir Kumar; Varadhan, Sowmya; Dhanya, L; Mukherjee, Sukhes; Mohana, S; Balakrishnan, V; Vasudevan, D M
2009-01-01
Chronic pancreatitis, an irreversible inflammatory disease of the pancreas, is associated with the replacement of the destroyed parenchyma by extended development of fibrosis. Despite marked progress in diagnostic tools, no consensus has been reached in diagnosis of chronic pancreatitis. In this study we examined the hematological and biochemical parameters among 40 chronic pancreatitis patients within 18 to 67 yrs. ESR level and ALP activity was elevated in 40% cases. Serum amylase activity increased in 32 patients and it showed significant correlation with ALP (r=0.458, p=0.003), CA-19.9 (r=0.556, p<0.001), and calcium level (r=-0.472, p=0.002). Type IV collagen level in chronic pancreatitis also elevated (164.4 ± 55.5 ng/ml) and showed negative significant correlation with calcium level (r= -0.505, p=0.001). However, no significant correlation was observed between amylase activity and type IV collagen (r=0.289, p= 0.07).
NASA Astrophysics Data System (ADS)
Huang, Xiaohua; El-Sayed, Ivan H.; El-Sayed, Mostafa A.
2005-08-01
Gold nanoparticles with unique optical properties offer useful applications in biotechnology. In this article two applications that we have developed are summarized, in one they are used in cancer cell diagnostics and in the other they are found to have catalytic property for the NADH oxidation reaction which is important in ATP formations. By conjugation with anti-EGFR antibodies which specifically target EGFR that are usually overexpressed on most cancer cells, gold nanoparticles are used as a molecular contrast agent for cancer cell diagnostics using their both strong surface plasmon absorption and efficient Mie scattering properties. Au nanoparticles are also good catalysts for many reactions due to their high surface to volume ratio. Au nanoparticles are found to be the catalyst for the NADH oxidation reaction. This was studied by monitoring the effect of the nanoparticles on NADH fluorescence intensity and lifetime as well as the change of the surface plasmon absorption band during the reaction.
Champagne Queloz, Annie; Klymkowsky, Michael W.; Stern, Elsbeth; Hafen, Ernst; Köhler, Katja
2017-01-01
Concept inventories, constructed based on an analysis of students’ thinking and their explanations of scientific situations, serve as diagnostics for identifying misconceptions and logical inconsistencies and provide data that can help direct curricular reforms. In the current project, we distributed the Biological Concepts Instrument (BCI) to 17-18-year-old students attending the highest track of the Swiss school system (Gymnasium). Students’ performances on many questions related to evolution, genetics, molecular properties and functions were diverse. Important common misunderstandings were identified in the areas of evolutionary processes, molecular properties and an appreciation of stochastic processes in biological systems. Our observations provide further evidence that the BCI is efficient in identifying specific areas where targeted instruction is required. Based on these observations we have initiated changes at several levels to reconsider how biological systems are presented to university biology studies with the goal of improving student’s foundational understanding. PMID:28493960
Comparison of four PCR methods for efficient detection of Trypanosoma cruzi in routine diagnostics.
Seiringer, Peter; Pritsch, Michael; Flores-Chavez, María; Marchisio, Edoardo; Helfrich, Kerstin; Mengele, Carolin; Hohnerlein, Stefan; Bretzel, Gisela; Löscher, Thomas; Hoelscher, Michael; Berens-Riha, Nicole
2017-07-01
Due to increased migration, Chagas disease has become an international health problem. Reliable diagnosis of chronically infected people is crucial for prevention of non-vectorial transmission as well as treatment. This study compared four distinct PCR methods for detection of Trypanosoma cruzi DNA for the use in well-equipped routine diagnostic laboratories. DNA was extracted of T. cruzi-positive and negative patients' blood samples and cultured T. cruzi, T. rangeli as well as Leishmania spp. One conventional and two real-time PCR methods targeting a repetitive Sat-DNA sequence as well as one conventional PCR method targeting the variable region of the kDNA minicircle were compared for sensitivity, intra- and interassay precision, limit of detection, specificity and cross-reactivity. Considering the performance, costs and ease of use, an algorithm for PCR-diagnosis of patients with a positive serology for T. cruzi antibodies was developed. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
[MITOCHONDRIAL DYSFUNCTION: MODERN ASPECTS OF THERAPY (REVIEW)].
Arveladze, G; Geladze, N; Khachapuridze, N; Bakhtadze, S; Kapanadze, N
2015-01-01
Mitochondrial diseases are considered as one of the major problems of modern interdisciplinary neonatology and pediatrics. Mitochondrial pathology can be revealed as refractory myoclonic or multifocal seizures, craniofacial dysostosis, dysmetabolic manifestations and respiratory disorders. Central nervous system (CNS), muscles, heart, liver and kidneys is involved in this pathological process. An important criterion for diagnosis of mitochondrial dysfunction is increases in blood lactate and pyruvate levels; the absolute criterion - molecular genetic diagnostic studies of mitochondrial DNA. Polymorphism of clinical symptoms complicates the process of early diagnostics, the lack clear recommendations complicates therapy. Modern aspects of treatment of mitochondrial dysfunction in various neurological syndromes are based primarily in improving the efficiency of the processes of oxidative phosphorylation at the system level. Dietary carbohydrate restriction, and medication (Coenzyme Q10, Idebenonum, Cofactors, drugs which reduce lactic acidosis- Dimephosphon, Dichloroacetate, Antioxidants, Anticonvulsants and Antidiabetic agents, vitamins C, E, K, hemotransfusions) is prescribed. Such complex approach allows us to achieve a reduction in lactate-acidosis, and improve the condition of patients in 70% of cases.
Manga, Selene; Perales, Rocio; Reaño, Maria; D'Ambrosio, Lia; Migliori, Giovanni Battista; Amicosante, Massimo
2016-11-01
Tuberculosis (TB) continues to cause an outsized burden of morbidity and mortality worldwide, still missing efficient and largely accessible diagnostic tools determining an appropriate control of the disease. Serological tests have the potentially to impact TB diagnosis, in particular in extreme clinical settings. The diagnostic performances of the TB-XT HEMA EXPRESS (HEMA-EXPRESS) immunochromatographic rapid test for active TB diagnosis, based on use of multiple Mycobacterium tuberculosis (MTB) specific antigens, have been evaluated in a large study multicentre TB case-finding study, in populations with different exposure level to TB. A total of 1,386 subjects were enrolled in the six participating centres in Peru: 290 active-TB and 1,096 unaffected subjects. The TB prevalence (overall 20.5%) varied between 4.0% and 41.1% in the different study groups. Overall, the HEMA-EXPRESS test had 30.6% sensitivity (range 3.9-77.9%) and 84.6% specificity (range 51.6-97.3%). A significant inverse correlation between test accuracy (overall 73.5%, range 40.4-96.4%) and TB prevalence in the various study populations was observed (Pearson's r=-0.7985; P=0.05). HEMA-EXPRESS, is rapid and relatively inexpensive test suitable for routine use in TB diagnosis. In low TB prevalence conditions, test performance appears in line with WHO Target Product Profile for TB diagnostics. Performances appear suboptimal in high TB prevalence settings. Appropriate set-up in operative clinical settings has to be considered for novel serological tests for TB diagnosis, particularly for formats suitable for point-of-care use.
Ponomarenko, Sergei A.; Surin, Nikolay M.; Borshchev, Oleg V.; Luponosov, Yuriy N.; Akimov, Dmitry Y.; Alexandrov, Ivan S.; Burenkov, Alexander A.; Kovalenko, Alexey G.; Stekhanov, Viktor N.; Kleymyuk, Elena A.; Gritsenko, Oleg T.; Cherkaev, Georgiy V.; Kechek'yan, Alexander S.; Serenko, Olga A.; Muzafarov, Aziz M.
2014-01-01
Organic luminophores are widely used in various optoelectronic devices, which serve for photonics, nuclear and particle physics, quantum electronics, medical diagnostics and many other fields of science and technology. Improving their spectral-luminescent characteristics for particular technical requirements of the devices is a challenging task. Here we show a new concept to universal solution of this problem by creation of nanostructured organosilicon luminophores (NOLs), which are a particular type of dendritic molecular antennas. They combine the best properties of organic luminophores and inorganic quantum dots: high absorption cross-section, excellent photoluminescence quantum yield, fast luminescence decay time and good processability. A NOL consists of two types of covalently bonded via silicon atoms organic luminophores with efficient Förster energy transfer between them. Using NOLs in plastic scintillators, widely utilized for radiation detection and in elementary particles discoveries, led to a breakthrough in their efficiency, which combines both high light output and fast decay time. Moreover, for the first time plastic scintillators, which emit light in the desired wavelength region ranging from 370 to 700 nm, have been created. We anticipate further applications of NOLs as working elements of pulsed dye lasers in photonics, optoelectronics and as fluorescent labels in biology and medical diagnostics. PMID:25293808
Bai, Min; Zhang, Hui-Ping; Xing, Jin-Fang; Shi, Qiu-Sheng; Gu, Ji-Ying; Li, Fan; Chen, Hui-Li; Zhang, Xue-Mei; Fang, Yun; Du, Lian-Fang
2015-01-01
To evaluate diagnostic performance of acoustic radiation force impulse (ARFI) technology for solid breast masses with different sizes and determine which features are most efficient. 271 solid breast masses in 242 women were examined with ARFI, and their shear wave velocities (SWVs), Virtual Touch tissue imaging (VTI) patterns, and area ratios (ARs) were measured and compared with their histopathological outcomes. Receiver operating characteristic curves (ROC) were calculated to assess diagnostic performance of ARFI for small masses (6-14 mm) and big masses (15-30 mm). SWV of mass was shown to be positively associated with mass size (P < 0.001). For small masses, area under ROC (Az) of AR was larger than that of SWV (P < 0.001) and VTI pattern (P < 0.001); no significant difference was found between Az of SWV and that of VTI pattern (P = 0.906). For big masses, Az of VTI pattern was less than that of SWV (P = 0.008) and AR (P = 0.002); no significant difference was identified between Az of SWV and that of AR (P = 0.584). For big masses, SWV and AR are both efficient measures; nevertheless, for small masses, AR seems to be the best feature.
Rosen, Allyson; Weitlauf, Julie C
2015-01-01
A screening measure of capacity to consent can provide an efficient method of determining the appropriateness of including individuals from vulnerable patient populations in research, particularly in circumstances in which no caregiver is available to provide surrogate consent. Seaman et al. (2015) cross-validate a measure of capacity to consent to research developed by Jeste et al. (2007). They provide data on controls, caregivers, and patients with mild cognitive impairment and dementia. The study demonstrates the importance of validating measures across disorders with different domains of incapacity, as well as the need for timely and appropriate follow-up with potential participants who yield positive screens. Ultimately clinical measures need to adapt to the dimensional diagnostic approaches put forward in DSM 5. Integrative models of constructs, such as capacity to consent, will make this process more efficient by avoiding the need to test measures in each disorder. Until then, cross-validation studies, such as the work by Seaman et al. (2015) are critical.
Long-term preservation of Leptospira spp.: challenges and prospects.
Philip, Noraini; Garba, Bashiru; Neela, Vasantha Kumari
2018-05-08
Preservation of leptospiral cultures is tantamount to success in leptospiral diagnostics, research, and development of preventive strategies. Each Leptospira isolate has imperative value not only in disease diagnosis but also in epidemiology, virulence, pathogenesis, and drug development studies. As the number of circulating leptospires is continuously increasing and congruent with the importance to retain their original characteristics and properties, an efficient long-term preservation is critically needed to be well-established. However, the preservation of Leptospira is currently characterized by difficulties and conflicting results mainly due to the biological nature of this organism. Hence, this review seeks to describe the efforts in developing efficient preservation methods, to discover the challenges in preserving this organism and to identify the factors that can contribute to an effective long-term preservation of Leptospira. Through the enlightenment of the previous studies, a potentially effective method has been suggested. The article also attempts to evaluate novel strategies used in other industrial and biotechnological preservation efforts and consider their potential application to the conservation of Leptospira spp.
Performance study of the neutron-TPC
NASA Astrophysics Data System (ADS)
Huang, Meng; Li, Yulan; Niu, Libo; Deng, Zhi; Cheng, Xiaolei; He, Li; Zhang, Hongyan; Fu, Jianqiang; Yan, Yangyang; Cai, Yiming; Li, Yuanjing
2017-02-01
Fast neutron spectrometers will play an important role in the future of the nuclear industry and nuclear physics experiments, in tasks such as fast neutron reactor monitoring, thermo-nuclear fusion plasma diagnostics, nuclear reaction cross-section measurement, and special nuclear material detection. Recently, a new fast neutron spectrometer based on a GEM (Gas Electron Multiplier amplification)-TPC (Time Projection Chamber), named the neutron-TPC, has been under development at Tsinghua University. It is designed to have a high energy resolution, high detection efficiency, easy access to the medium material, an outstanding n/γ suppression ratio, and a wide range of applications. This paper presents the design, test, and experimental study of the neutron-TPC. Based on the experimental results, the energy resolution (FWHM) of the neutron-TPC can reach 15.7%, 10.3% and 7.0% with detection efficiency higher than 10-5 for 1.2 MeV, 1.81 MeV and 2.5 MeV neutrons respectively. Supported by National Natural Science Foundation of China (11275109)
Frederick, R I
2000-01-01
Mixed group validation (MGV) is offered as an alternative to criterion group validation (CGV) to estimate the true positive and false positive rates of tests and other diagnostic signs. CGV requires perfect confidence about each research participant's status with respect to the presence or absence of pathology. MGV determines diagnostic efficiencies based on group data; knowing an individual's status with respect to pathology is not required. MGV can use relatively weak indicators to validate better diagnostic signs, whereas CGV requires perfect diagnostic signs to avoid error in computing true positive and false positive rates. The process of MGV is explained, and a computer simulation demonstrates the soundness of the procedure. MGV of the Rey 15-Item Memory Test (Rey, 1958) for 723 pre-trial criminal defendants resulted in higher estimates of true positive rates and lower estimates of false positive rates as compared with prior research conducted with CGV. The author demonstrates how MGV addresses all the criticisms Rogers (1997b) outlined for differential prevalence designs in malingering detection research. Copyright 2000 John Wiley & Sons, Ltd.
Nolan, Danielle; Carlson, Martha
2016-06-01
Genetic heterogeneity in neurologic disorders has been an obstacle to phenotype-based diagnostic testing. The authors hypothesized that information compiled via whole exome sequencing will improve clinical diagnosis and management of pediatric neurology patients. The authors performed a retrospective chart review of patients evaluated in the University of Michigan Pediatric Neurology clinic between 6/2011 and 6/2015. The authors recorded previous diagnostic testing, indications for whole exome sequencing, and whole exome sequencing results. Whole exome sequencing was recommended for 135 patients and obtained in 53 patients. Insurance barriers often precluded whole exome sequencing. The most common indication for whole exome sequencing was neurodevelopmental disorders. Whole exome sequencing improved the presumptive diagnostic rate in the patient cohort from 25% to 48%. Clinical implications included family planning, medication selection, and systemic investigation. Compared to current second tier testing, whole exome sequencing can result in lower long-term charges and more timely diagnosis. Overcoming barriers related to whole exome sequencing insurance authorization could allow for more efficient and fruitful diagnostic neurological evaluations. © The Author(s) 2016.
Li, Jia; Macdonald, Joanne
2016-09-15
Lateral flow biosensors are a leading technology in point-of-care diagnostics due to their simplicity, rapidness and low cost. Their primacy in this arena continues through technological breakthroughs such as multiplexing: the detection of more than one biomarker in a single assay. Multiplexing capacity is critical for improving diagnostic efficiency, enhancing the diagnostic precision for specific diseases and reducing diagnostic cost. Here we review, for the first time, the various types and strategies employed for creating multiplexed lateral flow biosensors. These are classified into four main categories in terms of specific application or multiplexing level, namely linear, parameter, spatial and conceptual. We describe the practical applications and implications for each approach and compare their advantages and disadvantages. Importantly, multiplexing is still subject to limitations of the traditional lateral flow biosensor, such as sensitivity and specificity. However, by pushing the limitations of the traditional medium into the multiplex arena, several technological breakthroughs are emerging with novel solutions that further expand the utility of lateral flow biosensing for point-of-care applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection.
Lau, Han Yih; Botella, Jose R
2017-01-01
Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail.
Advanced DNA-Based Point-of-Care Diagnostic Methods for Plant Diseases Detection
Lau, Han Yih; Botella, Jose R.
2017-01-01
Diagnostic technologies for the detection of plant pathogens with point-of-care capability and high multiplexing ability are an essential tool in the fight to reduce the large agricultural production losses caused by plant diseases. The main desirable characteristics for such diagnostic assays are high specificity, sensitivity, reproducibility, quickness, cost efficiency and high-throughput multiplex detection capability. This article describes and discusses various DNA-based point-of care diagnostic methods for applications in plant disease detection. Polymerase chain reaction (PCR) is the most common DNA amplification technology used for detecting various plant and animal pathogens. However, subsequent to PCR based assays, several types of nucleic acid amplification technologies have been developed to achieve higher sensitivity, rapid detection as well as suitable for field applications such as loop-mediated isothermal amplification, helicase-dependent amplification, rolling circle amplification, recombinase polymerase amplification, and molecular inversion probe. The principle behind these technologies has been thoroughly discussed in several review papers; herein we emphasize the application of these technologies to detect plant pathogens by outlining the advantages and disadvantages of each technology in detail. PMID:29375588
Overview of the electric propulsion plasma diagnostics suite for the VASIMR VX-200 testbed
NASA Astrophysics Data System (ADS)
Olsen, Christopher; Longmier, Benjamin; Ballenger, Maxwell; Squire, Jared; Glover, Tim; Carter, Mark; Bering, Edgar; Giambusso, Matthew
2012-10-01
Descriptions of the various plasma diagnostics and data analysis methods are given for instruments used in high power (> 100 kW) electric propulsion testing. These include planar Langmuir probes, an articulating retarding potential analyzer, a double Langmuir probe, a multi-axis magnetometer, a high frequency electric field probe, microwave interferometer, and momentum flux targets. These diagnostics have been used to measure the efficiencies of the thruster, plasma source, ion cyclotron resonance booster, and magnetic nozzle as well as used to explore physical phenomena in the plume such as ion/electron detachment, plasma turbulence, and magnetic field line stretching. Typical plume parameters range up to 10^13 cm-3 electron density, 1 kG applied magnetic fields, ion energies in excess of 150 eV, and cold electrons (2 -- 5 eV) with a spatial measurement range over 2 m.
NASA Astrophysics Data System (ADS)
Smyth, R. T.; Ballance, C. P.; Ramsbottom, C. A.; Johnson, C. A.; Ennis, D. A.; Loch, S. D.
2018-05-01
Neutral tungsten is the primary candidate as a wall material in the divertor region of the International Thermonuclear Experimental Reactor (ITER). The efficient operation of ITER depends heavily on precise atomic physics calculations for the determination of reliable erosion diagnostics, helping to characterize the influx of tungsten impurities into the core plasma. The following paper presents detailed calculations of the atomic structure of neutral tungsten using the multiconfigurational Dirac-Fock method, drawing comparisons with experimental measurements where available, and includes a critical assessment of existing atomic structure data. We investigate the electron-impact excitation of neutral tungsten using the Dirac R -matrix method, and by employing collisional-radiative models, we benchmark our results with recent Compact Toroidal Hybrid measurements. The resulting comparisons highlight alternative diagnostic lines to the widely used 400.88-nm line.
The value and validation of broad spectrum biosensors for diagnosis and biodefense
Metzgar, David; Sampath, Rangarajan; Rounds, Megan A; Ecker, David J
2013-01-01
Broad spectrum biosensors capable of identifying diverse organisms are transitioning from the realm of research into the clinic. These technologies simultaneously capture signals from a wide variety of biological entities using universal processes. Specific organisms are then identified through bioinformatic signature-matching processes. This is in contrast to currently accepted molecular diagnostic technologies, which utilize unique reagents and processes to detect each organism of interest. This paradigm shift greatly increases the breadth of molecular diagnostic tools with little increase in biochemical complexity, enabling simultaneous diagnostic, epidemiologic, and biothreat surveillance capabilities at the point of care. This, in turn, offers the promise of increased biosecurity and better antimicrobial stewardship. Efficient realization of these potential gains will require novel regulatory paradigms reflective of the generalized, information-based nature of these assays, allowing extension of empirical data obtained from readily available organisms to support broader reporting of rare, difficult to culture, or extremely hazardous organisms. PMID:24128433
Mandalà, Marco; Giannuzzi, Annalisa; Astore, Serena; Trabalzini, Franco; Nuti, Daniele
2013-07-01
We evaluated the incidence and characteristics of hyperventilation-induced nystagmus (HVN) in 49 patients with gadolinium-enhanced magnetic resonance imaging evidence of vestibular schwannoma and 53 patients with idiopathic unilateral sensorineural hearing loss and normal radiological findings. The sensitivity and specificity of the hyperventilation test were compared with other audio-vestibular diagnostic tests (bedside examination of eye movements, caloric test, auditory brainstem responses) in the two groups of patients. The hyperventilation test scored the highest diagnostic efficiency (sensitivity 65.3 %; specificity 98.1 %) of the four tests in the differential diagnosis of vestibular schwannoma and idiopathic unilateral sensorineural hearing loss. Small tumors with a normal caloric response or caloric paresis were associated with ipsilateral HVN and larger tumors and severe caloric deficits with contralateral HVN. These results confirm that the hyperventilation test is a useful diagnostic test for predicting vestibular schwannoma in patients with unilateral sensorineural hearing loss.
A proposed computer diagnostic system for malignant melanoma (CDSMM).
Shao, S; Grams, R R
1994-04-01
This paper describes a computer diagnostic system for malignant melanoma. The diagnostic system is a rule base system based on image analyses and works under the PC windows environment. It consists of seven modules: I/O module, Patient/Clinic database, image processing module, classification module, rule base module and system control module. In the system, the image analyses are automatically carried out, and database management is efficient and fast. Both final clinic results and immediate results from various modules such as measured features, feature pictures and history records of the disease lesion can be presented on screen or printed out from each corresponding module or from the I/O module. The system can also work as a doctor's office-based tool to aid dermatologists with details not perceivable by the human eye. Since the system operates on a general purpose PC, it can be made portable if the I/O module is disconnected.
Bovin, Michelle J; Marx, Brian P; Weathers, Frank W; Gallagher, Matthew W; Rodriguez, Paola; Schnurr, Paula P; Keane, Terence M
2016-11-01
This study examined the psychometric properties of the posttraumatic stress disorder (PTSD) Checklist for Diagnostic and Statistical Manual of Mental Disorders-Fifth Edition (PCL-5; Weathers, Litz, et al., 2013b) in 2 independent samples of veterans receiving care at a Veterans Affairs Medical Center (N = 468). A subsample of these participants (n = 140) was used to define a valid diagnostic cutoff score for the instrument using the Clinician-Administered PTSD Scale for DSM-5 (CAPS-5; Weathers, Blake, et al., 2013) as the reference standard. The PCL-5 test scores demonstrated good internal consistency (α = .96), test-retest reliability (r = .84), and convergent and discriminant validity. Consistent with previous studies (Armour et al., 2015; Liu et al., 2014), confirmatory factor analysis revealed that the data were best explained by a 6-factor anhedonia model and a 7-factor hybrid model. Signal detection analyses using the CAPS-5 revealed that PCL-5 scores of 31 to 33 were optimally efficient for diagnosing PTSD (κ(.5) = .58). Overall, the findings suggest that the PCL-5 is a psychometrically sound instrument that can be used effectively with veterans. Further, by determining a valid cutoff score using the CAPS-5, the PCL-5 can now be used to identify veterans with probable PTSD. However, findings also suggest the need for research to evaluate cluster structure of DSM-5. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Development of a Computerized Adaptive Test of Children's Gross Motor Skills.
Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Wu, Hing-Man; Chen, Kuan-Lin; Hsieh, Ching-Lin
2018-03-01
To (1) develop a computerized adaptive test for gross motor skills (GM-CAT) as a diagnostic test and an outcome measure, using the gross motor skills subscale of the Comprehensive Developmental Inventory for Infants and Toddlers (CDIIT-GM) as the candidate item bank; and (2) examine the psychometric properties and the efficiency of the GM-CAT. Retrospective study. A developmental center of a medical center. Children with and without developmental delay (N=1738). Not applicable. The CDIIT-GM contains 56 universal items on gross motor skills assessing children's antigravity control, locomotion, and body movement coordination. The item bank of the GM-CAT had 44 items that met the dichotomous Rasch model's assumptions. High Rasch person reliabilities were found for each estimated gross motor skill for the GM-CAT (Rasch person reliabilities =.940-.995, SE=.68-2.43). For children aged 6 to 71 months, the GM-CAT had good concurrent validity (r values =.97-.98), adequate to excellent diagnostic accuracy (area under receiver operating characteristics curve =.80-.98), and moderate to large responsiveness (effect size =.65-5.82). The averages of items administered for the GM-CAT were 7 to 11, depending on the age group. The results of this study support the use of the GM-CAT as a diagnostic and outcome measure to estimate children's gross motor skills in both research and clinical settings. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
42 CFR 440.130 - Diagnostic, screening, preventive, and rehabilitative services.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Promote physical and mental health and efficiency. (d) “Rehabilitative services,” except as otherwise... reduction of physical or mental disability and restoration of a recipient to his best possible functional... under State law, to enable him to identify the existence, nature, or extent of illness, injury, or other...
Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...
Physicians can boost shrinking revenues with in-house ancillary services.
2004-04-01
Physicians are examining a variety of mechanisms to capture new sources of revenue while improving efficiency and continuity of care. Adding on-site diagnostic and therapeutic services is one of the most effective ways to accomplish both of these goals, but physician groups must be wary of potential pitfalls.
USDA-ARS?s Scientific Manuscript database
Fecal culture is considered the gold standard for the diagnostics of paratuberculosis, however, PCR for the detection of Mycobacterium avium subsp. paratuberculosis (MAP) in fecal material is widely used today, having demonstrated great sensitivity and specificity. To insure the most efficient and r...
Ebola Virus Persistence in Semen Ex Vivo.
Fischer, Robert J; Judson, Seth; Miazgowicz, Kerri; Bushmaker, Trent; Munster, Vincent J
2016-02-01
On March 20, 2015, a case of Ebola virus disease was identified in Liberia that most likely was transmitted through sexual contact. We assessed the efficiency of detecting Ebola virus in semen samples by molecular diagnostics and the stability of Ebola virus in ex vivo semen under simulated tropical conditions.
An intelligent advisory system for pre-launch processing
NASA Technical Reports Server (NTRS)
Engrand, Peter A.; Mitchell, Tami
1991-01-01
The shuttle system of interest in this paper is the shuttle's data processing system (DPS). The DPS is composed of the following: (1) general purpose computers (GPC); (2) a multifunction CRT display system (MCDS); (3) mass memory units (MMU); and (4) a multiplexer/demultiplexer (MDM) and related software. In order to ensure the correct functioning of shuttle systems, some level of automatic error detection has been incorporated into all shuttle systems. For the DPS, error detection equipment has been incorporated into all of its subsystems. The automated diagnostic system, (MCDS) diagnostic tool, that aids in a more efficient processing of the DPS is described.
Gädke, Johannes; Thies, Jan-Wilhelm; Kleinfeldt, Lennart; Schulze, Torben; Biedendieck, Rebekka; Rustenbeck, Ingo; Garnweitner, Georg; Krull, Rainer; Dietzel, Andreas
2018-05-01
The needs of scalable product purification as well as the demand for sensitive diagnostics for highly dilute entities can be addressed with the utilization of tailored superparamagnetic nanoparticles. Recent developments have led to more efficient fluidic systems at different scales with suspended nanoparticles or nanoparticle aggregates. However, magnetic nanoparticle systems differ widely in properties and their applications are characterized by very specific challenges. This review summarizes advances in the synthesis of superparamagnetic particles and displays states and trends in research making use of these particles in biotechnological downstream processing and in biosensing. Copyright © 2017 Elsevier B.V. All rights reserved.
Biffa, Demelash; Bogale, Asseged; Skjerve, Eystein
2010-08-06
Bovine Tuberculosis (BTB) is a widespread and endemic disease of cattle in Ethiopia posing a significant threat to public health. Regular surveillance by skin test, bacteriology and molecular methods is not feasible due to lack of resource. Thus, routine abattoir (RA) inspection will continue to play a key role for national surveillance. We evaluated efficiency of RA inspection for diagnosis of Mycobacterium bovis infection and discussed its public health implications in light of a high risk of human exposure. The study was conducted in five abattoirs: Addis Ababa, Adama, Hawassa, Yabello and Melge-Wondo abattoirs. The efficiency of routine abattoir (RA) inspection was validated in comparison to detailed abattoir (DA) inspection, followed by culture and microscopy (CM) and region of difference (RD) deletion analysis. Diagnostic accuracies (with corresponding measures of statistical uncertainty) were determined by computing test property statistics (sensitivity and specificity) and likelihood estimations using web-based SISA diagnostic statistics software. Post-test probability of detecting TB infected carcasses was estimated using nomograms. Agreement between RA and DA inspections was measured using kappa statistics. The study was conducted and reported in accordance with standards for reporting of diagnostic accuracy (STARD) requirements. Both routine and detailed meat inspection protocols were performed on a subpopulation of 3322 cattle selected randomly from among 78,269 cattle slaughtered during the study period. Three hundred thirty seven carcasses identified through detailed meat inspection protocols were subjected to culture and microscopy; of the 337, a subset of 105 specimens for culture and microscopy were subjected to further molecular testing. There was a substantial agreement between RA and DA inspections in Addis Ababa (Kappa = 0.7) and Melge-Wondo abattoirs (Kappa = 0.67). In Adama, Hawassa and Yabello abattoirs, the agreement was however poor (Kappa
2010-01-01
Background Bovine Tuberculosis (BTB) is a widespread and endemic disease of cattle in Ethiopia posing a significant threat to public health. Regular surveillance by skin test, bacteriology and molecular methods is not feasible due to lack of resource. Thus, routine abattoir (RA) inspection will continue to play a key role for national surveillance. We evaluated efficiency of RA inspection for diagnosis of Mycobacterium bovis infection and discussed its public health implications in light of a high risk of human exposure. Methods The study was conducted in five abattoirs: Addis Ababa, Adama, Hawassa, Yabello and Melge-Wondo abattoirs. The efficiency of routine abattoir (RA) inspection was validated in comparison to detailed abattoir (DA) inspection, followed by culture and microscopy (CM) and region of difference (RD) deletion analysis. Diagnostic accuracies (with corresponding measures of statistical uncertainty) were determined by computing test property statistics (sensitivity and specificity) and likelihood estimations using web-based SISA diagnostic statistics software. Post-test probability of detecting TB infected carcasses was estimated using nomograms. Agreement between RA and DA inspections was measured using kappa statistics. The study was conducted and reported in accordance with standards for reporting of diagnostic accuracy (STARD) requirements. Both routine and detailed meat inspection protocols were performed on a subpopulation of 3322 cattle selected randomly from among 78,269 cattle slaughtered during the study period. Three hundred thirty seven carcasses identified through detailed meat inspection protocols were subjected to culture and microscopy; of the 337, a subset of 105 specimens for culture and microscopy were subjected to further molecular testing. Results There was a substantial agreement between RA and DA inspections in Addis Ababa (Kappa = 0.7) and Melge-Wondo abattoirs (Kappa = 0.67). In Adama, Hawassa and Yabello abattoirs, the agreement was however poor (Kappa ≤ 0.2). RA inspection was able to detect only 117 of the total 3322 carcasses inspected (3.5%). The sensitivity (Sn) and specificity (Sp) of RA inspection were 28.2% (95/337) [95%CI: 23.4-33.0] and 99.3% (2963/2985) [95%CI: 99.0-99.6], respectively, when DA inspection was considered as reference test. When culture and microscopy (CM) was considered as reference test, the Sn and Sp of RA were 55.2% (58/105) [95%CI: 45.7-64.7] and 84.1% (195/232) [95%CI: 79.3-88.8]. RA inspection failed to detect 71.8% (242/337) and 44.8% (47/105) of TB infected carcasses as judged by DA inspection and CM, respectively. On the other hand, a much higher sensitivity of DA was obtained when CM and RD deletion analysis were considered as reference tests (96.3% (105/109) and 100.0% (24/24), respectively). Conclusions The study results indicate that meat inspection protocols currently utilized in abattoirs are insufficient to detect the majority of TB lesions at the gross level. DA inspection protocols were demonstrated to improve the detection level by approximately 3-fold. The failure of current inspection techniques to detect approximately 70% of carcasses presented with grossly-visible lesions of TB at the slaughter-plants indicates the magnitude of meat-borne zoonotic TB as an on-going risk to public health. Standardization of abattoir inspection protocols (in line with international sanitary requirements), enhanced training and proficiency testing of meat inspections, and raising public awareness are recommended as essential and cost-effective interventions to improve meat inspection service in Ethiopia, with subsequent protection of consumers' health. PMID:20691081
Ion Voltage Diagnostics in the Far-Field Plume of a High-Specific Impulse Hall Thruster
NASA Technical Reports Server (NTRS)
Hofer, Richard R.; Haas, James M.; Gallimore, Alec D.
2003-01-01
The effects of the magnetic field and discharge voltage on the far-field plume of the NASA 173Mv2 laboratory-model Hall thruster were investigated. A cylindrical Langmuir probe was used to measure the plasma potential and a retarding potential analyzer was employed to measure the ion voltage distribution. The plasma potential was affected by relatively small changes in the external magnetic field, which suggested a means to control the plasma surrounding the thruster. As the discharge voltage increased, the ion voltage distribution showed that the acceleration efficiency increased and the dispersion efficiency decreased. This implied that the ionization zone was growing axially and moving closer to the anode, which could have affected thruster efficiency and lifetime due to higher wall losses. However, wall losses may have been reduced by improved focusing efficiency since the total efficiency increased and the plume divergence decreased with discharge voltage.
Portable devices and mobile instruments for infectious diseases point-of-care testing.
Bissonnette, Luc; Bergeron, Michel G
2017-05-01
Rapidity, simplicity, and portability are highly desirable characteristics of tests and devices designed for performing diagnostics at the point of care (POC), either near patients managed in healthcare facilities or to offer bioanalytical alternatives in external settings. By reducing the turnaround time of the diagnostic cycle, POC diagnostics can reduce the dissemination, morbidity, and mortality of infectious diseases and provide tools to control the global threat of antimicrobial resistance. Areas covered: A literature search of PubMed and Google Scholar, and extensive mining of specialized publications, Internet resources, and manufacturers' websites have been used to organize and write this overview of the challenges and requirements associated with the development of portable sample-to-answer diagnostics, and showcase relevant examples of handheld devices, portable instruments, and less mobile systems which may or could be operated at POC. Expert commentary: Rapid (<1 h) diagnostics can contribute to control infectious diseases and antimicrobial resistant pathogens. Portable devices or instruments enabling sample-to-answer bioanalysis can provide rapid, robust, and reproducible testing at the POC or close from it. Beyond testing, to realize some promises of personalized/precision medicine, it will be critical to connect instruments to healthcare data management systems, to efficiently link decentralized testing results to the electronic medical record of patients.
High-Content Optical Codes for Protecting Rapid Diagnostic Tests from Counterfeiting.
Gökçe, Onur; Mercandetti, Cristina; Delamarche, Emmanuel
2018-06-19
Warnings and reports on counterfeit diagnostic devices are released several times a year by regulators and public health agencies. Unfortunately, mishandling, altering, and counterfeiting point-of-care diagnostics (POCDs) and rapid diagnostic tests (RDTs) is lucrative, relatively simple and can lead to devastating consequences. Here, we demonstrate how to implement optical security codes in silicon- and nitrocellulose-based flow paths for device authentication using a smartphone. The codes are created by inkjet spotting inks directly on nitrocellulose or on micropillars. Codes containing up to 32 elements per mm 2 and 8 colors can encode as many as 10 45 combinations. Codes on silicon micropillars can be erased by setting a continuous flow path across the entire array of code elements or for nitrocellulose by simply wicking a liquid across the code. Static or labile code elements can further be formed on nitrocellulose to create a hidden code using poly(ethylene glycol) (PEG) or glycerol additives to the inks. More advanced codes having a specific deletion sequence can also be created in silicon microfluidic devices using an array of passive routing nodes, which activate in a particular, programmable sequence. Such codes are simple to fabricate, easy to view, and efficient in coding information; they can be ideally used in combination with information on a package to protect diagnostic devices from counterfeiting.
Get the Diagnosis: an evidence-based medicine collaborative Wiki for diagnostic test accuracy.
Hammer, Mark M; Kohlberg, Gavriel D
2017-04-01
Despite widespread calls for its use, there are challenges to the implementation of evidence-based medicine (EBM) in clinical practice. In response to the challenges of finding timely, pertinent information on diagnostic test accuracy, we developed an online, crowd-sourced Wiki on diagnostic test accuracy called Get the Diagnosis (GTD, http://www.getthediagnosis.org). Since its launch in November 2008 till October 2015, GTD has accumulated information on 300 diagnoses, with 1617 total diagnostic entries. There are a total of 1097 unique diagnostic tests with a mean of 5.4 tests (range 0-38) per diagnosis. 73% of entries (1182 of 1617) have an associated sensitivity and specificity and 89% of entries (1432 of 1617) have associated peer-reviewed literature citations. Altogether, GTD contains 474 unique literature citations. For a sample of three diagnoses, the search precision (percentage of relevant results in the first 30 entries) in GTD was 100% as compared with a range of 13.3%-63.3% for PubMed and between 6.7% and 76.7% for Google Scholar. GTD offers a fast, precise and efficient way to look up diagnostic test accuracy. On three selected examples, GTD had a greater precision rate compared with PubMed and Google Scholar in identifying diagnostic test information. GTD is a free resource that complements other currently available resources. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Warhurst, Geoffrey; Dunn, Graham; Chadwick, Paul; Blackwood, Bronagh; McAuley, Daniel; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Bentley, Andrew; Young, Duncan; Carlson, Gordon L; Dark, Paul
2015-05-01
There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. Critical care departments within NHS hospitals in the north-west of England. Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4-16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error. The systematic review is registered as PROSPERO CRD42011001289. The National Institute for Health Research Health Technology Assessment programme. Professor Daniel McAuley and Professor Gavin D Perkins contributed to the systematic review through their funded roles as codirectors of the Intensive Care Foundation (UK).
Perioperative circulating tumor cell detection: Current perspectives
Kaifi, Jussuf T.; Li, Guangfu; Clawson, Gary; Kimchi, Eric T.; Staveley-O'Carroll, Kevin F.
2016-01-01
ABSTRACT Primary cancer resections and in selected cases surgical metastasectomies significantly improve survival, however many patients develop recurrences. Circulating tumor cells (CTCs) function as an independent marker that could be used in the prognostication of different cancers. Sampling of blood and bone marrow compartments during cancer resections is a unique opportunity to increase individual tumor cell capture efficiency. This review will address the diagnostic and therapeutic potentials of perioperative tumor isolation and highlight the focus of future studies on characterization of single disseminated cancer cells to identify targets for molecular therapy and immune escape mechanisms. PMID:27045201
[Efficacy of high-frequency cinematography in diagnosis of dysphagia].
Oelerich, M; Mai, R; Müller-Miny, H; Peters, P E
1995-10-01
Dysphagia is a common symptom in clinical practice. Due to the broad spectrum of underlying diseases many disciplines are involved in the therapy and diagnosis of dysphagia, where radiology plays a central role. The radiologist is confronted with different diagnostic problems and has to choose the most appropriate type of investigation. In many cases no organic disorder can be demonstrated by clinical examination, endoscopy or conventional radiological techniques. In this setting cineradiography is an outstanding tool for finding functional or structural changes in the swallowing chain. This study underlines the efficiency of cineradiography in the diagnosis of dysphagia.
NASA Technical Reports Server (NTRS)
Schoen, A. H.; Rosenstein, H.; Stanzione, K.; Wisniewski, J. S.
1980-01-01
This report describes the use of the V/STOL Aircraft Sizing and Performance Computer Program (VASCOMP II). The program is useful in performing aircraft parametric studies in a quick and cost efficient manner. Problem formulation and data development were performed by the Boeing Vertol Company and reflects the present preliminary design technology. The computer program, written in FORTRAN IV, has a broad range of input parameters, to enable investigation of a wide variety of aircraft. User oriented features of the program include minimized input requirements, diagnostic capabilities, and various options for program flexibility.