Cancer Risks Associated with External Radiation From Diagnostic Imaging Procedures
Linet, Martha S.; Slovis, Thomas L.; Miller, Donald L.; Kleinerman, Ruth; Lee, Choonsik; Rajaraman, Preetha; de Gonzalez, Amy Berrington
2012-01-01
The 600% increase in medical radiation exposure to the US population since 1980 has provided immense benefit, but potential future cancer risks to patients. Most of the increase is from diagnostic radiologic procedures. The objectives of this review are to summarize epidemiologic data on cancer risks associated with diagnostic procedures, describe how exposures from recent diagnostic procedures relate to radiation levels linked with cancer occurrence, and propose a framework of strategies to reduce radiation from diagnostic imaging in patients. We briefly review radiation dose definitions, mechanisms of radiation carcinogenesis, key epidemiologic studies of medical and other radiation sources and cancer risks, and dose trends from diagnostic procedures. We describe cancer risks from experimental studies, future projected risks from current imaging procedures, and the potential for higher risks in genetically susceptible populations. To reduce future projected cancers from diagnostic procedures, we advocate widespread use of evidence-based appropriateness criteria for decisions about imaging procedures, oversight of equipment to deliver reliably the minimum radiation required to attain clinical objectives, development of electronic lifetime records of imaging procedures for patients and their physicians, and commitment by medical training programs, professional societies, and radiation protection organizations to educate all stakeholders in reducing radiation from diagnostic procedures. PMID:22307864
Pretty, Iain A; Maupomé, Gerardo
2004-04-01
Dentists are involved in diagnosing disease in every aspect of their clinical practice. A range of tests, systems, guides and equipment--which can be generally referred to as diagnostic procedures--are available to aid in diagnostic decision making. In this era of evidence-based dentistry, and given the increasing demand for diagnostic accuracy and properly targeted health care, it is important to assess the value of such diagnostic procedures. Doing so allows dentists to weight appropriately the information these procedures supply, to purchase new equipment if it proves more reliable than existing equipment or even to discard a commonly used procedure if it is shown to be unreliable. This article, the first in a 6-part series, defines several concepts used to express the usefulness of diagnostic procedures, including reliability and validity, and describes some of their operating characteristics (statistical measures of performance), in particular, specificity and sensitivity. Subsequent articles in the series will discuss the value of diagnostic procedures used in daily dental practice and will compare today's most innovative procedures with established methods.
Office-Based Procedures for the Diagnosis and Treatment of Laryngeal Pathology.
Wellenstein, David J; Schutte, Henrieke W; Takes, Robert P; Honings, Jimmie; Marres, Henri A M; Burns, James A; van den Broek, Guido B
2017-09-18
Since the development of distal chip endoscopes with a working channel, diagnostic and therapeutic possibilities in the outpatient clinic in the management of laryngeal pathology have increased. Which of these office-based procedures are currently available, and their clinical indications and possible advantages, remains unclear. Review of literature on office-based procedures in laryngology and head and neck oncology. Flexible endoscopic biopsy (FEB), vocal cord injection, and laser surgery are well-established office-based procedures that can be performed under topical anesthesia. These procedures demonstrate good patient tolerability and multiple advantages. Office-based procedures under topical anesthesia are currently an established method in the management of laryngeal pathology. These procedures offer medical and economic advantages compared with operating room-performed procedures. Furthermore, office-based procedures enhance the speed and timing of the diagnostic and therapeutic process. Copyright © 2017 The Voice Foundation. All rights reserved.
Office-based procedures for diagnosis and treatment of esophageal pathology.
Wellenstein, David J; Schutte, Henrieke W; Marres, Henri A M; Honings, Jimmie; Belafsky, Peter C; Postma, Gregory N; Takes, Robert P; van den Broek, Guido B
2017-09-01
Diagnostic and therapeutic office-based procedures under topical anesthesia are emerging in the daily practice of laryngologists and head and neck surgeons. Since the introduction of the transnasal esophagoscope, office-based procedures for the esophagus are increasingly performed. We conducted a systematic review of literature on office-based procedures under topical anesthesia for the esophagus. Transnasal esophagoscopy is an extensively investigated office-based procedure. This procedure shows better patient tolerability and equivalent accuracy compared to conventional transoral esophagoscopy, as well as time and cost savings. Secondary tracheoesophageal puncture, esophageal dilatation, esophageal sphincter injection, and foreign body removal are less investigated, but show promising results. With the introduction of the transnasal esophagoscope, an increasing number of diagnostic and therapeutic office-based procedures for the esophagus are possible, with multiple advantages. Further investigation must prove the clinical feasibility and effectiveness of the therapeutic office-based procedures. © 2017 Wiley Periodicals, Inc.
Haux, Reinhold
2017-01-01
In the era of digitization some new procedures play an increasing role for diagnosis as well as for therapy: informatics diagnostics and informatics therapeutics. Challenges for such procedures are described. It is discussed, when research on such diagnostics and therapeutics can be regarded as good research. Examples are mentioned for informatics diagnostics and informatics therapeutics, which are based on health-enabling technologies.
Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G
2018-03-01
Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.
Evaluating a Dental Diagnostic Terminology in an Electronic Health Record
White, Joel M.; Kalenderian, Elsbeth; Stark, Paul C.; Ramoni, Rachel L.; Vaderhobli, Ram; Walji, Muhammad F.
2011-01-01
Standardized treatment procedure codes and terms are routinely used in dentistry. Utilization of a diagnostic terminology is common in medicine, but there is not a satisfactory or commonly standardized dental diagnostic terminology available at this time. Recent advances in dental informatics have provided an opportunity for inclusion of diagnostic codes and terms as part of treatment planning and documentation in the patient treatment history. This article reports the results of the use of a diagnostic coding system in a large dental school’s predoctoral clinical practice. A list of diagnostic codes and terms, called Z codes, was developed by dental faculty members. The diagnostic codes and terms were implemented into an electronic health record (EHR) for use in a predoctoral dental clinic. The utilization of diagnostic terms was quantified. The validity of Z code entry was evaluated by comparing the diagnostic term entered to the procedure performed, where valid diagnosis-procedure associations were determined by consensus among three calibrated academically based dentists. A total of 115,004 dental procedures were entered into the EHR during the year sampled. Of those, 43,053 were excluded from this analysis because they represent diagnosis or other procedures unrelated to treatments. Among the 71,951 treatment procedures, 27,973 had diagnoses assigned to them with an overall utilization of 38.9 percent. Of the 147 available Z codes, ninety-three were used (63.3 percent). There were 335 unique procedures provided and 2,127 procedure/diagnosis pairs captured in the EHR. Overall, 76.7 percent of the diagnoses entered were valid. We conclude that dental diagnostic terminology can be incorporated within an electronic health record and utilized in an academic clinical environment. Challenges remain in the development of terms and implementation and ease of use that, if resolved, would improve the utilization. PMID:21546594
Bowling, Mark R; Kohan, Matthew W; Walker, Paul; Efird, Jimmy; Ben Or, Sharon
2015-01-01
Navigational bronchoscopy is utilized to guide biopsies of peripheral lung nodules and place fiducial markers for treatment of limited stage lung cancer with stereotactic body radiotherapy. The type of sedation used for this procedure remains controversial. We performed a retrospective chart review to evaluate the differences of diagnostic yield and overall success of the procedure based on anesthesia type. Electromagnetic navigational bronchoscopy was performed using the superDimension software system. Once the targeted lesion was within reach, multiple tissue samples were obtained. Statistical analysis was used to correlate the yield with the type of sedation among other factors. A successful procedure was defined if a diagnosis was made or a fiducial marker was adequately placed. Navigational bronchoscopy was performed on a total of 120 targeted lesions. The overall complication rate of the procedure was 4.1%. The diagnostic yield and success of the procedure was 74% and 87%, respectively. Duration of the procedure was the only significant difference between the general anesthesia and IV sedation groups (mean, 58 vs. 43 min, P=0.0005). A larger tumor size was associated with a higher diagnostic yield (P=0.032). All other variables in terms of effect on diagnostic yield and an unsuccessful procedure did not meet statistical significance. Navigational bronchoscopy is a safe and effective pulmonary diagnostic tool with relatively low complication rate. The diagnostic yield and overall success of the procedure does not seem to be affected by the type of sedation used.
Snyder, C R; Larsen, D L; Bloom, L J
1976-04-01
There was no difference in the acceptance of a general personality interpretation supposedly based on psychological, graphological, or astrological assessment procedures. Ss told that their general personality interpretation was based on one of the three assessment procedures, however, accepted the interpretation to a greater degree than did Ss told the interpretation was "generally true of people." S faith in all assessment procedures and perceived diagnostician skill increased significantly from before to after receipt of the diagnostic feedback. Ss elicited a halo response after they had received the interpretation, such that they generated a highly consistent positive (or negative) view of the assessment procedures and diagnostician skills. Implications of results from this acceptance paradigm were discussed for diagnosticians and therapists.
Itri, Jason N; Jones, Lisa P; Kim, Woojin; Boonn, William W; Kolansky, Ana S; Hilton, Susan; Zafar, Hanna M
2014-04-01
Monitoring complications and diagnostic yield for image-guided procedures is an important component of maintaining high quality patient care promoted by professional societies in radiology and accreditation organizations such as the American College of Radiology (ACR) and Joint Commission. These outcome metrics can be used as part of a comprehensive quality assurance/quality improvement program to reduce variation in clinical practice, provide opportunities to engage in practice quality improvement, and contribute to developing national benchmarks and standards. The purpose of this article is to describe the development and successful implementation of an automated web-based software application to monitor procedural outcomes for US- and CT-guided procedures in an academic radiology department. The open source tools PHP: Hypertext Preprocessor (PHP) and MySQL were used to extract relevant procedural information from the Radiology Information System (RIS), auto-populate the procedure log database, and develop a user interface that generates real-time reports of complication rates and diagnostic yield by site and by operator. Utilizing structured radiology report templates resulted in significantly improved accuracy of information auto-populated from radiology reports, as well as greater compliance with manual data entry. An automated web-based procedure log database is an effective tool to reliably track complication rates and diagnostic yield for US- and CT-guided procedures performed in a radiology department.
Polilli, Ennio; Sozio, Federica; Di Stefano, Paola; Clerico, Luigi; Di Iorio, Giancarlo; Parruti, Giustino
2018-04-01
This study aimed to analyze the efficacy of a Web-based testing programme in terms of the prevention of late HIV presentation. The clinical characteristics of patients diagnosed with HIV via the Web-based testing programme were compared to those of patients diagnosed in parallel via standard diagnostic care procedures. This study included the clinical and demographic data of newly diagnosed HIV patients enrolled at the study clinic between February 2014 and June 2017. These patients were diagnosed either via standard diagnostic procedures or as a result of the Web-based testing programme. Eighty-eight new cases of HIV were consecutively enrolled; their mean age was 39.1±13.0 years. Fifty-nine patients (67%) were diagnosed through standard diagnostic procedures and 29 (33%) patients came from the Web-based testing programme. Late presentation (62% vs. 34%, p=0.01) and AIDS-defining conditions at presentation (13 vs. 1, p=0.02) were significantly more frequent in the standard care group than in the Web-based group; four of 13 patients with AIDS diagnosed under standard diagnostic procedures died, versus none in the Web-based testing group (p<0.001). Web-based recruitment for voluntary and free HIV testing helped to diagnose patients with less advanced HIV disease and no risk of death, from all at-risk groups, in comparison with standard care testing. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
Failure mode analysis in adrenal vein sampling: a single-center experience.
Trerotola, Scott O; Asmar, Melissa; Yan, Yan; Fraker, Douglas L; Cohen, Debbie L
2014-10-01
To analyze failure modes in a high-volume adrenal vein sampling (AVS) practice in an effort to identify preventable causes of nondiagnostic sampling. A retrospective database was constructed containing 343 AVS procedures performed over a 10-year period. Each nondiagnostic AVS procedure was reviewed for failure mode and correlated with results of any repeat AVS. Data collected included selectivity index, lateralization index, adrenalectomy outcomes if performed, and details of AVS procedure. All AVS procedures were performed after cosyntropin stimulation, using sequential technique. AVS was nondiagnostic in 12 of 343 (3.5%) primary procedures and 2 secondary procedures. Failure was right-sided in 8 (57%) procedures, left-sided in 4 (29%) procedures, bilateral in 1 procedure, and neither in 1 procedure (laboratory error). Failure modes included diluted sample from correctly identified vein (n = 7 [50%]; 3 right and 4 left), vessel misidentified as adrenal vein (n = 3 [21%]; all right), failure to locate an adrenal vein (n = 2 [14%]; both right), cosyntropin stimulation failure (n = 1 [7%]; diagnostic by nonstimulated criteria), and laboratory error (n = 1 [7%]; specimen loss). A second AVS procedure was diagnostic in three of five cases (60%), and a third AVS procedure was diagnostic in one of one case (100%). Among the eight patients in whom AVS ultimately was not diagnostic, four underwent adrenalectomy based on diluted AVS samples, and one underwent adrenalectomy based on imaging; all five experienced improvement in aldosteronism. A substantial percentage of AVS failures occur on the left, all related to dilution. Even when technically nondiagnostic per strict criteria, some "failed" AVS procedures may be sufficient to guide therapy. Repeat AVS has a good yield. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
Acquiring, Representing, and Evaluating a Competence Model of Diagnostic Strategy.
ERIC Educational Resources Information Center
Clancey, William J.
This paper describes NEOMYCIN, a computer program that models one physician's diagnostic reasoning within a limited area of medicine. NEOMYCIN's knowledge base and reasoning procedure constitute a model of how human knowledge is organized and how it is used in diagnosis. The hypothesis is tested that such a procedure can be used to simulate both…
Diagnostic games: from adequate formalization of clinical experience to structure discovery.
Shifrin, Michael A; Kasparova, Eva I
2008-01-01
A method of obtaining well-founded and reproducible results in clinical decision making is presented. It is based on "diagnostic games", a procedure of elicitation and formalization of experts' knowledge and experience. The use of this procedure allows formulating decision rules in the terms of an adequate language, that are both unambiguous and clinically clear.
Computer-aided diagnostic strategy selection.
Greenes, R A
1986-03-01
Determination of the optimal diagnostic work-up strategy for the patient is becoming a major concern for the practicing physician. Overlap of the indications for various diagnostic procedures, differences in their invasiveness or risk, and high costs have made physicians aware of the need to consider the choice of procedure carefully, as well as its relation to management actions available. In this article, the author discusses research approaches that aim toward development of formal decision analytic methods to allow the physician to determine optimal strategy; clinical algorithms or rules as guides to physician decisions; improved measures for characterizing the performance of diagnostic tests; educational tools for increasing the familiarity of physicians with the concepts underlying these measures and analytic procedures; and computer-based aids for facilitating the employment of these resources in actual clinical practice.
Glais, Laurent; Jacquot, Emmanuel
2015-01-01
Numerous molecular-based detection protocols include an amplification step of the targeted nucleic acids. This step is important to reach the expected sensitive detection of pathogens in diagnostic procedures. Amplifications of nucleic acid sequences are generally performed, in the presence of appropriate primers, using thermocyclers. However, the time requested to amplify molecular targets and the cost of the thermocycler machines could impair the use of these methods in routine diagnostics. Recombinase polymerase amplification (RPA) technique allows rapid (short-term incubation of sample and primers in an enzymatic mixture) and simple (isothermal) amplification of molecular targets. RPA protocol requires only basic molecular steps such as extraction procedures and agarose gel electrophoresis. Thus, RPA can be considered as an interesting alternative to standard molecular-based diagnostic tools. In this paper, the complete procedures to set up an RPA assay, applied to detection of RNA (Potato virus Y, Potyvirus) and DNA (Wheat dwarf virus, Mastrevirus) viruses, are described. The proposed procedure allows developing species- or subspecies-specific detection assay.
A Framework to Debug Diagnostic Matrices
NASA Technical Reports Server (NTRS)
Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann
2013-01-01
Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.
Frameless robotically targeted stereotactic brain biopsy: feasibility, diagnostic yield, and safety.
Bekelis, Kimon; Radwan, Tarek A; Desai, Atman; Roberts, David W
2012-05-01
Frameless stereotactic brain biopsy has become an established procedure in many neurosurgical centers worldwide. Robotic modifications of image-guided frameless stereotaxy hold promise for making these procedures safer, more effective, and more efficient. The authors hypothesized that robotic brain biopsy is a safe, accurate procedure, with a high diagnostic yield and a safety profile comparable to other stereotactic biopsy methods. This retrospective study included 41 patients undergoing frameless stereotactic brain biopsy of lesions (mean size 2.9 cm) for diagnostic purposes. All patients underwent image-guided, robotic biopsy in which the SurgiScope system was used in conjunction with scalp fiducial markers and a preoperatively selected target and trajectory. Forty-five procedures, with 50 supratentorial targets selected, were performed. The mean operative time was 44.6 minutes for the robotic biopsy procedures. This decreased over the second half of the study by 37%, from 54.7 to 34.5 minutes (p < 0.025). The diagnostic yield was 97.8% per procedure, with a second procedure being diagnostic in the single nondiagnostic case. Complications included one transient worsening of a preexisting deficit (2%) and another deficit that was permanent (2%). There were no infections. Robotic biopsy involving a preselected target and trajectory is safe, accurate, efficient, and comparable to other procedures employing either frame-based stereotaxy or frameless, nonrobotic stereotaxy. It permits biopsy in all patients, including those with small target lesions. Robotic biopsy planning facilitates careful preoperative study and optimization of needle trajectory to avoid sulcal vessels, bridging veins, and ventricular penetration.
Vlahiotis, Anna; Griffin, Brian; Stavros, A Thomas; Margolis, Jay
2018-01-01
Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam. To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures. Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy) other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event), with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes. The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients), 6,987,399 breast ultrasounds (42.4% of patients), and 1,585,856 biopsies (10.3% of patients). Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD) costs for diagnostic mammograms of US$349 ($493), ultrasounds US$132 ($134), and biopsies US$1,938 ($2,343) contributed US$3.05 billion, US$0.92 billion, and US$3.07 billion, respectively, to annual diagnostic breast expenditures estimated at US$7.91 billion. The volume and expense of additional breast diagnostic testing, estimated at US$7.91 billion annually, underscores the need for technological improvements in the breast diagnostic landscape.
Willegaignon, José; Braga, Luis F E F; Sapienza, Marcelo T; Coura-Filho, George B; Cardona, Marissa A R; Alves, Carlos E R; Gutterres, Ricardo F; Buchpiguel, Carlos A
2016-05-01
This study aimed to establish a concise method for determining a diagnostic reference level (DRL) for adult and pediatric nuclear medicine patients on the basis of diagnostic procedures and administered radioisotope as a means of controlling medical exposure. A screening was carried out in all Brazilian Nuclear Medicine Service (NMS) establishments to support this study by collecting the average activities administered during adult diagnostic procedures and the rules applied to adjust these according to the patient's age and body mass. Percentile 75 was used in all the activities administered as a means of establishing DRL for adult patients, with additional correction factors for pediatric patients. Radiation doses from nuclear medicine procedures on the basis of average administered activity were calculated for all diagnostic exams. A total of 107 NMSs in Brazil agreed to participate in the project. From the 64 nuclear medicine procedures studied, bone, kidney, and parathyroid scans were found to be used in more than 85% of all the NMSs analyzed. There was a large disparity among the activities administered, when applying the same procedures, this reaching, in some cases, more than 20 times between the lowest and the highest. Diagnostic exams based on Ga, Tl, and I radioisotopes proved to be the major exams administering radiation doses to patients. On introducing the DRL concept into clinical routine, the minimum reduction in radiation doses received by patients was about 15%, the maximum was 95%, and the average was 50% compared with the previously reported administered activities. Variability in the available diagnostic procedures as well as in the amount of activities administered within the same procedure was appreciable not only in Brazil, but worldwide. Global efforts are needed to establish a concise DRL that can be applied in adult and pediatric nuclear medicine procedures as the application of DRL in clinical routine has been proven to be an important tool for controlling and reducing radiation doses received by patients in medical exposure.
Kluge, Annette; Grauel, Britta; Burkolter, Dina
2013-03-01
Two studies are presented in which the design of a procedural aid and the impact of an additional decision aid for process control were assessed. In Study 1, a procedural aid was developed that avoids imposing unnecessary extraneous cognitive load on novices when controlling a complex technical system. This newly designed procedural aid positively affected germane load, attention, satisfaction, motivation, knowledge acquisition and diagnostic speed for novel faults. In Study 2, the effect of a decision aid for use before the procedural aid was investigated, which was developed based on an analysis of diagnostic errors committed in Study 1. Results showed that novices were able to diagnose both novel faults and practised faults, and were even faster at diagnosing novel faults. This research contributes to the question of how to optimally support novices in dealing with technical faults in process control. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Alrashdan, Abdalla; Momani, Amer; Ababneh, Tamador
2012-01-01
One of the most challenging problems facing healthcare providers is to determine the actual cost for their procedures, which is important for internal accounting and price justification to insurers. The objective of this paper is to find suitable categories to identify the diagnostic outpatient medical procedures and translate them from functional orientation to process orientation. A hierarchal task tree is developed based on a classification schema of procedural activities. Each procedure is seen as a process consisting of a number of activities. This makes a powerful foundation for activity-based cost/management implementation and provides enough information to discover the value-added and non-value-added activities that assist in process improvement and eventually may lead to cost reduction. Work measurement techniques are used to identify the standard time of each activity at the lowest level of the task tree. A real case study at a private hospital is presented to demonstrate the proposed methodology. © 2011 National Association for Healthcare Quality.
Homogeneity tests of clustered diagnostic markers with applications to the BioCycle Study
Tang, Liansheng Larry; Liu, Aiyi; Schisterman, Enrique F.; Zhou, Xiao-Hua; Liu, Catherine Chun-ling
2014-01-01
Diagnostic trials often require the use of a homogeneity test among several markers. Such a test may be necessary to determine the power both during the design phase and in the initial analysis stage. However, no formal method is available for the power and sample size calculation when the number of markers is greater than two and marker measurements are clustered in subjects. This article presents two procedures for testing the accuracy among clustered diagnostic markers. The first procedure is a test of homogeneity among continuous markers based on a global null hypothesis of the same accuracy. The result under the alternative provides the explicit distribution for the power and sample size calculation. The second procedure is a simultaneous pairwise comparison test based on weighted areas under the receiver operating characteristic curves. This test is particularly useful if a global difference among markers is found by the homogeneity test. We apply our procedures to the BioCycle Study designed to assess and compare the accuracy of hormone and oxidative stress markers in distinguishing women with ovulatory menstrual cycles from those without. PMID:22733707
20 CFR 404.1519m - Diagnostic tests or procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Diagnostic tests or procedures. 404.1519m... Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic... will not order diagnostic tests or procedures that involve significant risk to you, such as myelograms...
2011-01-01
Background The International Multi-centre ADHD Genetics (IMAGE) project with 11 participating centres from 7 European countries and Israel has collected a large behavioural and genetic database for present and future research. Behavioural data were collected from 1068 probands with the combined type of attention deficit/hyperactivity disorder (ADHD-CT) and 1446 'unselected' siblings. The aim was to analyse the IMAGE sample with respect to demographic features (gender, age, family status, and recruiting centres) and psychopathological characteristics (diagnostic subtype, symptom frequencies, age at symptom detection, and comorbidities). A particular focus was on the effects of the study design and the diagnostic procedure on the homogeneity of the sample in terms of symptom-based behavioural data, and potential consequences for further analyses based on these data. Methods Diagnosis was based on the Parental Account of Childhood Symptoms (PACS) interview and the DSM-IV items of the Conners' teacher questionnaire. Demographics of the full sample and the homogeneity of a subsample (all probands) were analysed by using robust statistical procedures which were adjusted for unequal sample sizes and skewed distributions. These procedures included multi-way analyses based on trimmed means and winsorised variances as well as bootstrapping. Results Age and proband/sibling ratios differed between participating centres. There was no significant difference in the distribution of gender between centres. There was a significant interaction between age and centre for number of inattentive, but not number of hyperactive symptoms. Higher ADHD symptom frequencies were reported by parents than teachers. The diagnostic symptoms differed from each other in their frequencies. The face-to-face interview was more sensitive than the questionnaire. The differentiation between ADHD-CT probands and unaffected siblings was mainly due to differences in hyperactive/impulsive symptoms. Conclusions Despite a symptom-based standardized inclusion procedure according to DSM-IV criteria with defined symptom thresholds, centres may differ markedly in probands' ADHD symptom frequencies. Both the diagnostic procedure and the multi-centre design influence the behavioural characteristics of a sample and, thus, may bias statistical analyses, particularly in genetic or neurobehavioral studies. PMID:21473745
The Use of Information Based Evaluation in Evaluating the Diagnostic Teaching Center.
ERIC Educational Resources Information Center
Poteet, James A.
Information Based Evaluation (IBE) is identified as a design procedure for assessing a variety of projects, programs, and educational changes. IBE was used to evaluate a Comprehensive Diagnostic Teaching Center (DTC) which, in addition to providing teacher training and services to handicapped pupils, would bring together and focus all of the…
20 CFR 220.60 - Diagnostic surgical procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Diagnostic surgical procedures. 220.60... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation of...
20 CFR 220.60 - Diagnostic surgical procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false Diagnostic surgical procedures. 220.60... DETERMINING DISABILITY Consultative Examinations § 220.60 Diagnostic surgical procedures. The Board will not order diagnostic surgical procedures such as myelograms and arteriograms for the evaluation of...
Algorithm for Video Summarization of Bronchoscopy Procedures
2011-01-01
Background The duration of bronchoscopy examinations varies considerably depending on the diagnostic and therapeutic procedures used. It can last more than 20 minutes if a complex diagnostic work-up is included. With wide access to videobronchoscopy, the whole procedure can be recorded as a video sequence. Common practice relies on an active attitude of the bronchoscopist who initiates the recording process and usually chooses to archive only selected views and sequences. However, it may be important to record the full bronchoscopy procedure as documentation when liability issues are at stake. Furthermore, an automatic recording of the whole procedure enables the bronchoscopist to focus solely on the performed procedures. Video recordings registered during bronchoscopies include a considerable number of frames of poor quality due to blurry or unfocused images. It seems that such frames are unavoidable due to the relatively tight endobronchial space, rapid movements of the respiratory tract due to breathing or coughing, and secretions which occur commonly in the bronchi, especially in patients suffering from pulmonary disorders. Methods The use of recorded bronchoscopy video sequences for diagnostic, reference and educational purposes could be considerably extended with efficient, flexible summarization algorithms. Thus, the authors developed a prototype system to create shortcuts (called summaries or abstracts) of bronchoscopy video recordings. Such a system, based on models described in previously published papers, employs image analysis methods to exclude frames or sequences of limited diagnostic or education value. Results The algorithm for the selection or exclusion of specific frames or shots from video sequences recorded during bronchoscopy procedures is based on several criteria, including automatic detection of "non-informative", frames showing the branching of the airways and frames including pathological lesions. Conclusions The paper focuses on the challenge of generating summaries of bronchoscopy video recordings. PMID:22185344
Pannell, J Scott; Santiago-Dieppa, David R; Wali, Arvin R; Hirshman, Brian R; Steinberg, Jeffrey A; Cheung, Vincent J; Oveisi, David; Hallstrom, Jon; Khalessi, Alexander A
2016-08-29
This study establishes performance metrics for angiography and neuroendovascular surgery procedures based on longitudinal improvement in individual trainees with differing levels of training and experience. Over the course of 30 days, five trainees performed 10 diagnostic angiograms, coiled 10 carotid terminus aneurysms in the setting of subarachnoid hemorrhage, and performed 10 left middle cerebral artery embolectomies on a Simbionix Angio Mentor™ simulator. All procedures were nonconsecutive. Total procedure time, fluoroscopy time, contrast dose, heart rate, blood pressures, medications administered, packing densities, the number of coils used, and the number of stent-retriever passes were recorded. Image quality was rated, and the absolute value of technically unsafe events was recorded. The trainees' device selection, macrovascular access, microvascular access, clinical management, and the overall performance of the trainee was rated during each procedure based on a traditional Likert scale score of 1=fail, 2=poor, 3=satisfactory, 4=good, and 5=excellent. These ordinal values correspond with published assessment scales on surgical technique. After performing five diagnostic angiograms and five embolectomies, all participants demonstrated marked decreases in procedure time, fluoroscopy doses, contrast doses, and adverse technical events; marked improvements in image quality, device selection, access scores, and overall technical performance were additionally observed (p < 0.05). Similarly, trainees demonstrated marked improvement in technical performance and clinical management after five coiling procedures (p < 0.05). However, trainees with less prior experience deploying coils continued to experience intra-procedural ruptures up to the eighth embolization procedure; this observation likely corresponded with less tactile procedural experience to an exertion of greater force than appropriate for coil placement. Trainees across all levels of training and prior experience demonstrated a significant performance improvement after completion of our simulator curriculum consisting of five diagnostic angiograms, five embolectomy cases, and 10 aneurysm coil embolizations.
42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... and other diagnostic procedures. 413.122 Section 413.122 Public Health CENTERS FOR MEDICARE & MEDICAID... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements... services and other diagnostic procedures performed by a hospital on an outpatient basis. (2) For purposes...
[Costing nuclear medicine diagnostic procedures].
Markou, Pavlos
2005-01-01
To the Editor: Referring to a recent special report about the cost analysis of twenty-nine nuclear medicine procedures, I would like to clarify some basic aspects for determining costs of nuclear medicine procedure with various costing methodologies. Activity Based Costing (ABC) method, is a new approach in imaging services costing that can provide the most accurate cost data, but is difficult to perform in nuclear medicine diagnostic procedures. That is because ABC requires determining and analyzing all direct and indirect costs of each procedure, according all its activities. Traditional costing methods, like those for estimating incomes and expenses per procedure or fixed and variable costs per procedure, which are widely used in break-even point analysis and the method of ratio-of-costs-to-charges per procedure may be easily performed in nuclear medicine departments, to evaluate the variability and differences between costs and reimbursement - charges.
Decker, Sebastian O; Sigl, Annette; Grumaz, Christian; Stevens, Philip; Vainshtein, Yevhen; Zimmermann, Stefan; Weigand, Markus A; Hofer, Stefan; Sohn, Kai; Brenner, Thorsten
2017-08-18
Fungi are of increasing importance in sepsis. However, culture-based diagnostic procedures are associated with relevant weaknesses. Therefore, culture- and next-generation sequencing (NGS)-based fungal findings as well as corresponding plasma levels of β-d-glucan, interferon gamma (INF-γ), tumor necrosis factor alpha (TNF-α), interleukin (IL)-2, -4, -6, -10, -17A, and mid-regional proadrenomedullin (MR-proADM) were evaluated in 50 septic patients at six consecutive time points within 28 days after sepsis onset. Furthermore, immune-response patterns during infections with Candida spp. were studied in a reconstituted human epithelium model. In total, 22% ( n = 11) of patients suffered from a fungal infection. An NGS-based diagnostic approach appeared to be suitable for the identification of fungal pathogens in patients suffering from fungemia as well as in patients with negative blood cultures. Moreover, MR-proADM and IL-17A in plasma proved suitable for the identification of patients with a fungal infection. Using RNA-seq., adrenomedullin (ADM) was shown to be a target gene which is upregulated early after an epithelial infection with Candida spp. In summary, an NGS-based diagnostic approach was able to close the diagnostic gap of routinely used culture-based diagnostic procedures, which can be further facilitated by plasmatic measurements of MR-proADM and IL-17A. In addition, ADM was identified as an early target gene in response to epithelial infections with Candida spp.
A Self-Diagnostic System for the M6 Accelerometer
NASA Technical Reports Server (NTRS)
Flanagan, Patrick M.; Lekki, John
2001-01-01
The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.
20 CFR 416.919m - Diagnostic tests or procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Diagnostic tests or procedures. 416.919m... for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any diagnostic tests or procedures that have been performed as part of a workup by your treating source or other...
[Is evidence-based assessment fact or fiction? A bibliometric analysis of three German journals].
Petermann, Franz; Schüssler, Gerhard; Glaesmer, Heide
2008-01-01
Despite the ongoing process for the development and dissemination of empirically supported treatments, little attention has been paid to the development of evidence-based diagnostics. The article aims at evaluating diagnostic procedures and instruments in current clinical research in terms of evidence-based assessment. Volumes 2006 and 2007 of three German psychological journals "Psychotherapeut," "Psychotherapie, Psychosomatik und Medizinische Psychologie," and "Zeitschrift für Psychiatrie, Psychologie und Psychotherapie" were screened for empirical reports and articles dealing with diagnostic issues. 93 articles were identified and evaluated. Most studies used psychometrically valid and established instruments for assessment. However, diagnostic interviews were relatively scarce, as were multimodal assessments. Measures used for outcome evaluation often lacked evidence of sensitivity to change. Clinical assessment to date does not meet criteria for evidence-based diagnostics. Implications for research and guideline development are discussed.
Larson, Paul S; Willie, Jon T; Vadivelu, Sudhakar; Azmi-Ghadimi, Hooman; Nichols, Amy; Fauerbach, Loretta Litz; Johnson, Helen Boehm; Graham, Denise
2017-07-01
The development of navigation technology facilitating MRI-guided stereotactic neurosurgery has enabled neurosurgeons to perform a variety of procedures ranging from deep brain stimulation to laser ablation entirely within an intraoperative or diagnostic MRI suite while having real-time visualization of brain anatomy. Prior to this technology, some of these procedures required multisite workflow patterns that presented significant risk to the patient during transport. For those facilities with access to this technology, safe practice guidelines exist only for procedures performed within an intraoperative MRI. There are currently no safe practice guidelines or parameters available for facilities looking to integrate this technology into practice in conventional MRI suites. Performing neurosurgical procedures in a diagnostic MRI suite does require precautionary measures. The relative novelty of technology and workflows for direct MRI-guided procedures requires consideration of safe practice recommendations, including those pertaining to infection control and magnet safety issues. This article proposes a framework of safe practice recommendations designed for assessing readiness and optimization of MRI-guided neurosurgical interventions in the diagnostic MRI suite in an effort to mitigate patient risk. The framework is based on existing clinical evidence, recommendations, and guidelines related to infection control and prevention, health care-associated infections, and magnet safety, as well as the clinical and practical experience of neurosurgeons utilizing this technology. © 2017 American Society for Healthcare Risk Management of the American Hospital Association.
Updating Allergy and/or Hypersensitivity Diagnostic Procedures in the WHO ICD-11 Revision.
Tanno, Luciana Kase; Calderon, Moises A; Li, James; Casale, Thomas; Demoly, Pascal
2016-01-01
The classification of allergy and/or hypersensitivity conditions for the World Health Organization (WHO) International Classification of Diseases (ICD)-11 provides the appropriate corresponding codes for allergic diseases, assuming that the final diagnosis is correct. This classification should be linked to in vitro and in vivo diagnostic procedures. Considering the impact for our specialty, we decided to review the codification of these procedures into the ICD aiming to have a baseline and to suggest changes and/or submit new proposals. For that, we prepared a list of the relevant allergy and/or hypersensitivity diagnostic procedures that health care professionals are dealing with on a daily basis. This was based on the main current guidelines and selected all possible and relevant corresponding terms from the ICD-10 (2015 version) and the ICD-11 β phase foundation (June 2015 version). More than 90% of very specific and important diagnostic procedures currently used by the allergists' community on a daily basis are missing. We observed that some concepts usually used by the allergist community on a daily basis are not fully recognized by other specialties. The whole scheme and the correspondence in the ICD-10 (2015 version) and ICD-11 foundation (June 2015 version) provided us a big picture of the missing or imprecise terms and how they are scattered in the current ICD-11 framework, allowing us to submit new proposals to increase the visibility of the allergy and/or hypersensitivity conditions and diagnostic procedures. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. All rights reserved.
Spacelab Life Sciences-1 electrical diagnostic expert system
NASA Technical Reports Server (NTRS)
Kao, C. Y.; Morris, W. S.
1989-01-01
The Spacelab Life Sciences-1 (SLS-1) Electrical Diagnostic (SLED) expert system is a continuous, real time knowledge-based system to monitor and diagnose electrical system problems in the Spacelab. After fault isolation, the SLED system provides corrective procedures and advice to the ground-based console operator. The SLED system updates its knowledge about the status of Spacelab every 3 seconds. The system supports multiprocessing of malfunctions and allows multiple failures to be handled simultaneously. Information which is readily available via a mouse click includes: general information about the system and each component, the electrical schematics, the recovery procedures of each malfunction, and an explanation of the diagnosis.
Decker, Sebastian O.; Sigl, Annette; Grumaz, Christian; Stevens, Philip; Vainshtein, Yevhen; Zimmermann, Stefan; Weigand, Markus A.; Hofer, Stefan; Sohn, Kai; Brenner, Thorsten
2017-01-01
Fungi are of increasing importance in sepsis. However, culture-based diagnostic procedures are associated with relevant weaknesses. Therefore, culture- and next-generation sequencing (NGS)-based fungal findings as well as corresponding plasma levels of β-d-glucan, interferon gamma (INF-γ), tumor necrosis factor alpha (TNF-α), interleukin (IL)-2, -4, -6, -10, -17A, and mid-regional proadrenomedullin (MR-proADM) were evaluated in 50 septic patients at six consecutive time points within 28 days after sepsis onset. Furthermore, immune-response patterns during infections with Candida spp. were studied in a reconstituted human epithelium model. In total, 22% (n = 11) of patients suffered from a fungal infection. An NGS-based diagnostic approach appeared to be suitable for the identification of fungal pathogens in patients suffering from fungemia as well as in patients with negative blood cultures. Moreover, MR-proADM and IL-17A in plasma proved suitable for the identification of patients with a fungal infection. Using RNA-seq., adrenomedullin (ADM) was shown to be a target gene which is upregulated early after an epithelial infection with Candida spp. In summary, an NGS-based diagnostic approach was able to close the diagnostic gap of routinely used culture-based diagnostic procedures, which can be further facilitated by plasmatic measurements of MR-proADM and IL-17A. In addition, ADM was identified as an early target gene in response to epithelial infections with Candida spp. PMID:28820494
78 FR 20103 - Radiation Protection Guidance for Diagnostic and Interventional X-Ray Procedures
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-03
... for Diagnostic and Interventional X-Ray Procedures AGENCY: Environmental Protection Agency (EPA... for Diagnostic and Interventional X-Ray Procedures. This document is Federal Guidance Report No. 14. It replaces Federal Guidance Report No. 9, ``Radiation Protection Guidance for Diagnostic X-rays...
Chen, Chun-Nan; Lin, Che-Yi; Chi, Fan-Hsiang; Chou, Chen-Han; Hsu, Ya-Ching; Kuo, Yen-Lin; Lin, Chih-Feng; Chen, Tseng-Cheng; Wang, Cheng-Ping; Lou, Pei-Jen; Ko, Jenq-Yuh; Hsiao, Tzu-Yu; Yang, Tsung-Lin
2016-01-01
Abstract Tumors of the supraclavicular fossa (SC) is clinically challenging because of anatomical complexity and tumor pathological diversity. Because of varied diseases entities and treatment choices of SC tumors, making the accurate decision among numerous differential diagnoses is imperative. Sampling by open biopsy (OB) remains the standard procedure for pathological confirmation. However, complicated anatomical structures of SC always render surgical intervention difficult to perform. Ultrasound-guided core biopsy (USCB) is a minimally invasive and office-based procedure for tissue sampling widely applied in many diseases of head and neck. This study aims to evaluate the clinical efficacy and utility of using USCB as the sampling method of SC tumors. From 2009 to 2014, consecutive patients who presented clinical symptoms and signs of supraclavicular tumors and were scheduled to receive sampling procedures for diagnostic confirmation were recruited. The patients received USCB or OB respectively in the initial tissue sampling. The accurate diagnostic rate based on pathological results was 90.2% for USCB, and 93.6% for OB. No significant difference was noted between USCB and OB groups in terms of diagnostic accuracy and the percentage of inadequate specimens. All cases in the USCB group had the sampling procedure completed within 10 minutes, but not in the OB group. No scars larger than 1 cm were found in USCB. Only patients in the OB groups had the need to receive general anesthesia and hospitalization and had scars postoperatively. Accordingly, USCB can serve as the first-line sampling tool for SC tumors with high diagnostic accuracy, minimal invasiveness, and low medical cost. PMID:26825877
Statistical Analysis of Q-matrix Based Diagnostic Classification Models
Chen, Yunxiao; Liu, Jingchen; Xu, Gongjun; Ying, Zhiliang
2014-01-01
Diagnostic classification models have recently gained prominence in educational assessment, psychiatric evaluation, and many other disciplines. Central to the model specification is the so-called Q-matrix that provides a qualitative specification of the item-attribute relationship. In this paper, we develop theories on the identifiability for the Q-matrix under the DINA and the DINO models. We further propose an estimation procedure for the Q-matrix through the regularized maximum likelihood. The applicability of this procedure is not limited to the DINA or the DINO model and it can be applied to essentially all Q-matrix based diagnostic classification models. Simulation studies are conducted to illustrate its performance. Furthermore, two case studies are presented. The first case is a data set on fraction subtraction (educational application) and the second case is a subsample of the National Epidemiological Survey on Alcohol and Related Conditions concerning the social anxiety disorder (psychiatric application). PMID:26294801
40 CFR 85.2222 - On-board diagnostic test procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 19 2013-07-01 2013-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...
40 CFR 85.2222 - On-board diagnostic test procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 19 2012-07-01 2012-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...
40 CFR 85.2222 - On-board diagnostic test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...
Doing More for More: Unintended Consequences of Financial Incentives for Oncology Specialty Care.
O'Neil, Brock; Graves, Amy J; Barocas, Daniel A; Chang, Sam S; Penson, David F; Resnick, Matthew J
2016-02-01
Specialty care remains a significant contributor to health care spending but largely unaddressed in novel payment models aimed at promoting value-based delivery. Bladder cancer, chiefly managed by subspecialists, is among the most costly. In 2005, Centers for Medicare and Medicaid Services (CMS) dramatically increased physician payment for office-based interventions for bladder cancer to shift care from higher cost facilities, but the impact is unknown. This study evaluated the effect of financial incentives on patterns of fee-for-service (FFS) bladder cancer care. Data from a 5% sample of Medicare beneficiaries from 2001-2013 were evaluated using interrupted time-series analysis with segmented regression. Primary outcomes were the effects of CMS fee modifications on utilization and site of service for procedures associated with the diagnosis and treatment of bladder cancer. Rates of related bladder cancer procedures that were not affected by the fee change were concurrent controls. Finally, the effect of payment changes on both diagnostic yield and need for redundant procedures were studied. All statistical tests were two-sided. Utilization of clinic-based procedures increased by 644% (95% confidence interval [CI] = 584% to 704%) after the fee change, but without reciprocal decline in facility-based procedures. Procedures unaffected by the fee incentive remained unchanged throughout the study period. Diagnostic yield decreased by 17.0% (95% CI = 12.7% to 21.3%), and use of redundant office-based procedures increased by 76.0% (95% CI = 59% to 93%). Financial incentives in bladder cancer care have unintended and costly consequences in the current FFS environment. The observed price sensitivity is likely to remain a major issue in novel payment models failing to incorporate procedure-based specialty physicians. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Bergman, Lars G; Fors, Uno GH
2008-01-01
Background Correct diagnosis in psychiatry may be improved by novel diagnostic procedures. Computerized Decision Support Systems (CDSS) are suggested to be able to improve diagnostic procedures, but some studies indicate possible problems. Therefore, it could be important to investigate CDSS systems with regard to their feasibility to improve diagnostic procedures as well as to save time. Methods This study was undertaken to compare the traditional 'paper and pencil' diagnostic method SCID1 with the computer-aided diagnostic system CB-SCID1 to ascertain processing time and accuracy of diagnoses suggested. 63 clinicians volunteered to participate in the study and to solve two paper-based cases using either a CDSS or manually. Results No major difference between paper and pencil and computer-supported diagnosis was found. Where a difference was found it was in favour of paper and pencil. For example, a significantly shorter time was found for paper and pencil for the difficult case, as compared to computer support. A significantly higher number of correct diagnoses were found in the diffilt case for the diagnosis 'Depression' using the paper and pencil method. Although a majority of the clinicians found the computer method supportive and easy to use, it took a longer time and yielded fewer correct diagnoses than with paper and pencil. Conclusion This study could not detect any major difference in diagnostic outcome between traditional paper and pencil methods and computer support for psychiatric diagnosis. Where there were significant differences, traditional paper and pencil methods were better than the tested CDSS and thus we conclude that CDSS for diagnostic procedures may interfere with diagnosis accuracy. A limitation was that most clinicians had not previously used the CDSS system under study. The results of this study, however, confirm that CDSS development for diagnostic purposes in psychiatry has much to deal with before it can be used for routine clinical purposes. PMID:18261222
Case-Deletion Diagnostics for Nonlinear Structural Equation Models
ERIC Educational Resources Information Center
Lee, Sik-Yum; Lu, Bin
2003-01-01
In this article, a case-deletion procedure is proposed to detect influential observations in a nonlinear structural equation model. The key idea is to develop the diagnostic measures based on the conditional expectation of the complete-data log-likelihood function in the EM algorithm. An one-step pseudo approximation is proposed to reduce the…
40 CFR 86.1806-05 - On-board diagnostics for vehicles less than or equal to 14,000 pounds GVWR.
Code of Federal Regulations, 2012 CFR
2012-07-01
... once per applicable certification test cycle as defined in paragraphs (a) and (d) of Appendix I of this...-based test procedures), excluding those test procedures defined as “Supplemental” test procedures in... infeasibility. Malfunctions are defined as a failure of the system or component to meet the electrical circuit...
40 CFR 86.1806-05 - On-board diagnostics for vehicles less than or equal to 14,000 pounds GVWR.
Code of Federal Regulations, 2013 CFR
2013-07-01
... once per applicable certification test cycle as defined in paragraphs (a) and (d) of Appendix I of this...-based test procedures), excluding those test procedures defined as “Supplemental” test procedures in... infeasibility. Malfunctions are defined as a failure of the system or component to meet the electrical circuit...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Procedures for preparing egg yolk samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic...
Advances in diagnostic interventional pulmonology
Al-Zubaidi, Nassar; Soubani, Ayman O.
2015-01-01
The recent advances in diagnostic pulmonary procedures have revolutionized the evaluation of abnormal thoracic findings including lung nodules and masses, mediastinal lymphadenopathy, and pleural diseases. Bronchoscopies with endobronchial ultrasonography and electromagnetic navigation are examples of new technology that has significantly improved the specificity and sensitivity of these procedures in diagnosis and staging of lung cancer without the need for more invasive procedures. This report describes the different diagnostic pulmonary interventions providing a description of the procedures, their indications, diagnostic yield and drawback. PMID:26229756
Hada, Mahesh Singh; Chakravarty, Abhijit; Mukherjee, Partha
2014-01-01
Context: Escalating health care expenses pose a new challenge to the health care environment of becoming more cost-effective. There is an urgent need for more accurate data on the costs of health care procedures. Demographic changes, changing morbidity profile, and the rising impact of noncommunicable diseases are emphasizing the role of nuclear medicine (NM) in the future health care environment. However, the impact of emerging disease load and stagnant resource availability needs to be balanced by a strategic drive towards optimal utilization of available healthcare resources. Aim: The aim was to ascertain the cost of diagnostic procedures conducted at the NM Department of a tertiary health care facility by employing activity based costing (ABC) method. Materials and Methods: A descriptive cross-sectional study was carried out over a period of 1 year. ABC methodology was utilized for ascertaining unit cost of different diagnostic procedures and such costs were compared with prevalent market rates for estimating cost effectiveness of the department being studied. Results: The cost per unit procedure for various procedures varied from Rs. 869 (USD 14.48) for a thyroid scan to Rs. 11230 (USD 187.16) for a meta-iodo-benzyl-guanidine (MIBG) scan, the most cost-effective investigations being the stress thallium, technetium-99 m myocardial perfusion imaging (MPI) and MIBG scan. The costs obtained from this study were observed to be competitive when compared to prevalent market rates. Conclusion: ABC methodology provides precise costing inputs and should be used for all future costing studies in NM Departments. PMID:25400363
[Diagnostic imaging of urolithiais. Current recommendations and new developments].
Thalgott, M; Kurtz, F; Gschwend, J E; Straub, M
2015-07-01
Prevalence of urolithiasis is increasing in industrialized countries--in both adults and children, representing a unique diagnostic and therapeutic challenge. Risk-adapted diagnostic imaging currently means assessment with maximized sensitivity and specificity together with minimal radiation exposure. In clinical routine, imaging is performed by sonography, unenhanced computed tomography (NCCT) or intravenous urography (IVU) as well as plain kidney-ureter-bladder (KUB) radiographs. The aim of the present review is a critical guideline-based and therapy-aligned presentation of diagnostic imaging procedures for optimized treatment of urolithiasis considering the specifics in children and pregnant women.
TFTR diagnostic control and data acquisition system
NASA Astrophysics Data System (ADS)
Sauthoff, N. R.; Daniels, R. E.
1985-05-01
General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.
TFTR diagnostic control and data acquisition system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division
1985-05-01
General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.
Crowe, Sonya; Brown, Kate L; Pagel, Christina; Muthialu, Nagarajan; Cunningham, David; Gibbs, John; Bull, Catherine; Franklin, Rodney; Utley, Martin; Tsang, Victor T
2013-05-01
The study objective was to develop a risk model incorporating diagnostic information to adjust for case-mix severity during routine monitoring of outcomes for pediatric cardiac surgery. Data from the Central Cardiac Audit Database for all pediatric cardiac surgery procedures performed in the United Kingdom between 2000 and 2010 were included: 70% for model development and 30% for validation. Units of analysis were 30-day episodes after the first surgical procedure. We used logistic regression for 30-day mortality. Risk factors considered included procedural information based on Central Cardiac Audit Database "specific procedures," diagnostic information defined by 24 "primary" cardiac diagnoses and "univentricular" status, and other patient characteristics. Of the 27,140 30-day episodes in the development set, 25,613 were survivals, 834 were deaths, and 693 were of unknown status (mortality, 3.2%). The risk model includes procedure, cardiac diagnosis, univentricular status, age band (neonate, infant, child), continuous age, continuous weight, presence of non-Down syndrome comorbidity, bypass, and year of operation 2007 or later (because of decreasing mortality). A risk score was calculated for 95% of cases in the validation set (weight missing in 5%). The model discriminated well; the C-index for validation set was 0.77 (0.81 for post-2007 data). Removal of all but procedural information gave a reduced C-index of 0.72. The model performed well across the spectrum of predicted risk, but there was evidence of underestimation of mortality risk in neonates undergoing operation from 2007. The risk model performs well. Diagnostic information added useful discriminatory power. A future application is risk adjustment during routine monitoring of outcomes in the United Kingdom to assist quality assurance. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Davies, N.; Davies-Shaw, D.; Shaw, J. D.
2007-02-01
We report firsthand on innovative developments in non-invasive, biophotonic techniques for a wide range of diagnostic, imaging and treatment options, including the recognition and quantification of cancerous, pre-cancerous cells and chronic inflammatory conditions. These techniques have benefited from the ability to target the affected site by both monochromatic light and broad multiple wavelength spectra. The employment of such wavelength or color-specific properties embraces the fluorescence stimulation of various photosensitizing drugs, and the instigation and detection of identified fluorescence signatures attendant upon laser induced fluorescence (LIF) phenomena as transmitted and propagated by precancerous, cancerous and normal tissue. In terms of tumor imaging and therapeutic and treatment options, we have exploited the abilities of various wavelengths to penetrate to different depths, through different types of tissues, and have explored quantifiable absorption and reflection characteristics upon which diagnostic assumptions can be reliably based and formulated. These biophotonic-based diagnostic, sensing and imaging techniques have also benefited from, and have been further enhanced by, the integrated ability to provide various power levels to be employed at various stages in the procedure. Applications are myriad, including non-invasive, non destructive diagnosis of in vivo cell characteristics and functions; light-based tissue analysis; real-time monitoring and mapping of brain function and of tumor growth; real time monitoring of the surgical completeness of tumor removal during laser-imaged/guided brain resection; diagnostic procedures based on fluorescence life-time monitoring, the monitoring of chronic inflammatory conditions (including rheumatoid arthritis), and continuous blood glucose monitoring in the control of diabetes.
ERIC Educational Resources Information Center
Tyunnikov, Yurii S.
2016-01-01
The paper solves the problem of the relationship of external diagnosis and self-diagnosis of readiness of teachers to innovative activity. It highlights major disadvantages of measurement tools that are used to this process. The author demonstrates an alternative approach to harmonizing the diagnosis, based on a modular diagnostic model, general…
ERIC Educational Resources Information Center
Klingbeil, David A.; Nelson, Peter M.; Van Norman, Ethan R.; Birr, Chris
2017-01-01
We examined the diagnostic accuracy and efficiency of three approaches to universal screening for reading difficulties using retrospective data from 1,307 students in Grades 3 through 5. School staff collected screening data using the Measures of Academic Progress (MAP), a curriculum-based measure (CBM), and running records (RR). The criterion…
NASA Astrophysics Data System (ADS)
Shevchik, S. A.; Meerovich, Gennadii A.; Budzinskaya, M. V.; Ermakova, N. A.; Kharnas, Sergey S.; Loschenov, Victor B.
2004-06-01
A laser-spectroscopy complex was developed for fluorescent diagnostics and photodynamic therapy of age related macula degeneration using the Russian photosensitizer Photosense. The complex is based on slit lamp which was additionally equipped with an optical adapter, and the video adapter allows to combine the procedure of photodynamic therapy and the control of its carrying in the frame work of one procedure. The sensitivity and spatial resolution of the complex were investigated using a special test object. The availability of the developed complex and Photosense itself was examined on experimental animals.
NASA Technical Reports Server (NTRS)
Glover, R. C.; Kelley, B. A.; Tischer, A. E.
1986-01-01
The results of a review of the Space Shuttle Main Engine (SSME) failure data for the period 1980 through 1983 are presented. The data was collected, evaluated, and ranked according to procedures established during this study. A number of conclusions and recommendations are made based upon this failure data review. The results of a state-of-the-art diagnostic survey are also presented. This survey covered a broad range of diagnostic sensors and techniques and the findings were evaluated for application to the SSME. Finally, a discussion of the initial activities for the on-going SSME diagnostic evaluation is included.
Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees
NASA Technical Reports Server (NTRS)
Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann
2009-01-01
The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities
[Small-cell lung cancer: epidemiology, diagnostics and therapy].
Pešek, Miloš; Mužík, Jan
Authors present actual overview of information on diagnostic and therapeutic procedures in small-cell lung cancer (SCLC). This highly aggressive type of lung cancer is diagnosed in 14.8 % of Czech lung cancer patients. Vast majority of those patients (87 %) suffer from advanced and metastatic disease in the time of diagnosis. In this issue are presented prognostic factors, staging diagnostic procedures and therapeutic recommendations. The backbone of actual SCLC treatment is combined chemotherapy and radiotherapy and less frequently, carefully in selected cases, surgical procedures. SCLC should be have as chemosensitive, chemoresistent or chemorefractory disease. Actual cytostatic combinations used in 1st line treatment, different schedules of chemoradiotherapy, drugs used in second line treatment and schedules and timing of prophylactic brain irradiation are presented. In near future, perspectively, there are some promissible data on antitumour immunotherapy based on anti CTLA-4 and anti PD-1/PE-L1 antibodies also in SCLC patients.Key words: cancer immunotherapy - concomitant chemoradiotherapy - chemotherapy - chest radiotherapy - lung resections - prophylactic brain irradiation - small cell lung cancer.
Cannon, W Dilworth; Nicandri, Gregg T; Reinig, Karl; Mevis, Howard; Wittstein, Jocelyn
2014-04-02
Several virtual reality simulators have been developed to assist orthopaedic surgeons in acquiring the skills necessary to perform arthroscopic surgery. The purpose of this study was to assess the construct validity of the ArthroSim virtual reality arthroscopy simulator by evaluating whether skills acquired through increased experience in the operating room lead to improved performance on the simulator. Using the simulator, six postgraduate year-1 orthopaedic residents were compared with six postgraduate year-5 residents and with six community-based orthopaedic surgeons when performing diagnostic arthroscopy. The time to perform the procedure was recorded. To ensure that subjects did not sacrifice the quality of the procedure to complete the task in a shorter time, the simulator was programmed to provide a completeness score that indicated whether the surgeon accurately performed all of the steps of diagnostic arthroscopy in the correct sequence. The mean time to perform the procedure by each group was 610 seconds for community-based orthopaedic surgeons, 745 seconds for postgraduate year-5 residents, and 1028 seconds for postgraduate year-1 residents. Both the postgraduate year-5 residents and the community-based orthopaedic surgeons performed the procedure in significantly less time (p = 0.006) than the postgraduate year-1 residents. There was a trend toward significance (p = 0.055) in time to complete the procedure when the postgraduate year-5 residents were compared with the community-based orthopaedic surgeons. The mean level of completeness as assigned by the simulator for each group was 85% for the community-based orthopaedic surgeons, 79% for the postgraduate year-5 residents, and 71% for the postgraduate year-1 residents. As expected, these differences were not significant, indicating that the three groups had achieved an acceptable level of consistency in their performance of the procedure. Higher levels of surgeon experience resulted in improved efficiency when performing diagnostic knee arthroscopy on the simulator. Further validation studies utilizing the simulator are currently under way and the additional simulated tasks of arthroscopic meniscectomy, meniscal repair, microfracture, and loose body removal are being developed.
Siddique, Iqbal; Mohan, Krishna; Hasan, Fuad; Memon, Anjum; Patty, Istvan; Al-Nakib, Basil
2005-11-28
To assess the appropriateness of referrals and to determine the diagnostic yield of colonoscopy according to the 2000 guidelines of the American Society for Gastrointestinal Endoscopy (ASGE). A total of 736 consecutive patients (415 males, 321 females; mean age 43.6+/-16.6 years) undergoing colonoscopy during October 2001-March 2002 were prospectively enrolled in the study. The 2000 ASGE guidelines were used to assess the appropriateness of the indications for the procedure. Diagnostic yield was defined as the ratio between significant findings detected on colonoscopy and the total number of procedures performed for that indication. The large majority (64%) of patients had colonoscopy for an indication that was considered "generally indicated", it was "generally not indicated" for 20%, and it was "not listed" for 16% in the guidelines. The diagnostic yield of colonoscopy was highest for the "generally indicated" (38%) followed by "not listed" (13%) and "generally not indicated" (5%) categories. In the multivariable analysis, the diagnostic yield was independently associated with the appropriateness of indication that was "generally indicated" (odds ratio=12.3) and referrals by gastroenterologist (odds ratio =1.9). There is a high likelihood of inappropriate referrals for colonoscopy in an open-access endoscopy system. The diagnostic yield of the procedure is dependent on the appropriateness of indication and referring physician's specialty. Certain indications "not listed" in the guidelines have an intermediate diagnostic yield and further studies are required to evaluate whether they should be included in future revisions of the ASGE guidelines.
Kuhnigk, H; Steinhübel, B; Keil, T; Roewer, N
2004-07-01
Anaesthesia management, radiological diagnostic and the concept of damage control surgery should be combined in the resuscitation room. Defined clinical targets and their realisation are a CT-scan and complete damage control surgery in the shock room. Furthermore minimised patient transfer and positioning with continuous access to the head, upper parts of the body and anaesthesia machine should be realised during diagnostic procedures. Based on a carbon-slide fixed on a turntable and innovative alignment of diagnostic devices, a three phase treatment algorithm has been established. Phase A includes primary survey, anaesthetic management and ultrasound examination. Following a turn of the table conventional x-ray diagnostic is assessed in phase B. Tracks for the slide enable immediate transfer to a spiral CT-scan without additional patient positioning (phase C). Following complete CT-scan rearrangement of the table to phase A facilitates immediate damage control surgery. To accelerate device operation and treatment the integrated anaesthesia workstation is ceiling-mounted and manoeuvres close to the patient. This concept realizes complete diagnostic procedures and damage control surgery without time consuming patient transfer or rearrangement.
Martin, F N; Coffey, M D; Zeller, K; Hamelin, R C; Tooley, P; Garbelotto, M; Hughes, K J D; Kubisiak, T; Bilodeau, G J; Levy, L; Blomquist, C; Berger, P H
2009-04-01
Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World Phytophthora Genetic Resource Collection for 315 isolates representing 60 described Phytophthora spp. as well as 11 taxonomically unclassified isolates. These were sent blind to collaborators in seven laboratories to evaluate published diagnostic procedures using conventional (based on internal transcribed spacer [ITS] and cytochrome oxidase gene [cox]1 and 2 spacer regions) and real-time polymerase chain reaction (based on ITS and cox1 and 2 spacer regions as well as beta-tubulin and elicitin genes). Single-strand conformation polymorphism (SSCP) analysis using an automated sequencer for data collection was also evaluated for identification of all species tested. In general, the procedures worked well, with varying levels of specificity observed among the different techniques. With few exceptions, all assays correctly identified all isolates of P. ramorum and low levels of false positives were observed for the mitochondrial cox spacer markers and most of the real-time assays based on nuclear markers (diagnostic specificity between 96.9 and 100%). The highest level of false positives was obtained with the conventional nested ITS procedure; however, this technique is not stand-alone and is used in conjunction with two other assays for diagnostic purposes. The results indicated that using multiple assays improved the accuracy of the results compared with looking at a single assay alone, in particular when the markers represented different genetic loci. The SSCP procedure accurately identified P. ramorum and was helpful in classification of a number of isolates to a species level. With one exception, all procedures accurately identified P. ramorum in blind evaluations of 60 field samples that included examples of plant infection by 11 other Phytophthora spp. The SSCP analysis identified eight of these species, with three identified to a species group.
Kabbasch, C; Dorn, F; Wenchel, H M; Krug, B; Mpotsaris, A; Liebig, T
2017-03-01
Bacterial contamination during angiographic procedures is a potential source of bacteremia. It is largely unknown whether it is clinically relevant. Our aim was to evaluate the incidence of contamination of liquids during catheter-based neuroangiographic examinations, the spectrum of microorganisms, a comparison of two different trolley-settings, and a follow-up of all patients with regard to clinical and lab signs of infection. A total of 170 patients underwent either diagnostic angiography (n = 111) or arterial neuroendovascular procedures (n = 59). To study the impact of airborne contamination of sterile liquids, we randomly assigned equal numbers of procedures to two distinct setups. Group A with standard open-surface bowls and group B with repetitive coverage of liquids throughout the procedure. Patient preparation was performed with utmost care. After each procedure, samples of the liquids were sent for microbiological evaluation. Patients were followed for signs of infection (fever, white blood cell count, C-reactive-protein). Of all samples, 25.3 % were contaminated. Contamination consisted of resident skin microbiota only and was more common with procedures (28.8 %) than with diagnostic angiography (23.4 %) and less common in uncovered (23.5 %) than in covered bowls (27.1 %). However, these differences were insignificant. None of the patients developed clinical or lab signs of infection. Contamination during diagnostic and interventional angiography does occur and cannot be avoided by intermittent coverage. Despite a surprisingly high incidence, our findings support the common strategy that antibiotic coverage is unnecessary in most patients undergoing arterial angiography as it lacks clinical impact. Airborne contamination does not appear to play a role.
Innovation in diagnostic imaging services: assessing the potential for value-based reimbursement.
Garrison, Louis P; Bresnahan, Brian W; Higashi, Mitchell K; Hollingworth, William; Jarvik, Jeffrey G
2011-09-01
Innovation in the field of diagnostic imaging is based primarily on the availability of new and improved equipment that opens the door for new clinical applications. Payments for these imaging procedures are subject to complex Medicare price control schemes, affecting incentives for appropriate use and innovation. Achieving a "dynamically efficient" health care system-one that elicits a socially optimal amount of innovation-requires that innovators be rewarded in relation to the value they add and can demonstrate with evidence. The authors examine how and whether value-based reimbursement for diagnostic imaging services might better reward innovation explicitly for expected improvements in health and economic outcomes. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.
Conwell, Darwin L; Lee, Linda S; Yadav, Dhiraj; Longnecker, Daniel S; Miller, Frank H; Mortele, Koenraad J; Levy, Michael J; Kwon, Richard; Lieb, John G; Stevens, Tyler; Toskes, Phillip P; Gardner, Timothy B; Gelrud, Andres; Wu, Bechien U; Forsmark, Christopher E; Vege, Santhi S
2014-11-01
The diagnosis of chronic pancreatitis remains challenging in early stages of the disease. This report defines the diagnostic criteria useful in the assessment of patients with suspected and established chronic pancreatitis. All current diagnostic procedures are reviewed, and evidence-based statements are provided about their utility and limitations. Diagnostic criteria for chronic pancreatitis are classified as definitive, probable, or insufficient evidence. A diagnostic (STEP-wise; survey, tomography, endoscopy, and pancreas function testing) algorithm is proposed that proceeds from a noninvasive to a more invasive approach. This algorithm maximizes specificity (low false-positive rate) in subjects with chronic abdominal pain and equivocal imaging changes. Furthermore, a nomenclature is suggested to further characterize patients with established chronic pancreatitis based on TIGAR-O (toxic, idiopathic, genetic, autoimmune, recurrent, and obstructive) etiology, gland morphology (Cambridge criteria), and physiologic state (exocrine, endocrine function) for uniformity across future multicenter research collaborations. This guideline will serve as a baseline manuscript that will be modified as new evidence becomes available and our knowledge of chronic pancreatitis improves.
[Evaluation of quality of HIV diagnostic procedures in Poland].
Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna
2010-01-01
The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.
Precision medicine based on epigenomics: the paradigm of carcinoma of unknown primary.
Moran, Sebastián; Martinez-Cardús, Anna; Boussios, Stergios; Esteller, Manel
2017-11-01
Epigenetic alterations are a common hallmark of human cancer. Single epigenetic markers are starting to be incorporated into clinical practice; however, the translational use of these biomarkers has not been validated at the 'omics' level. The identification of the tissue of origin in patients with cancer of unknown primary (CUP) is an example of how epigenomics can be incorporated in clinical settings, addressing an unmet need in the diagnostic and clinical management of these patients. Despite the great diagnostic advances made in the past decade, the use of traditional diagnostic procedures only enables the tissue of origin to be determined in ∼30% of patients with CUP. Thus, development of molecularly guided diagnostic strategies has emerged to complement traditional procedures, thereby improving the clinical management of patients with CUP. In this Review, we present the latest data on strategies using epigenetics and other molecular biomarkers to guide therapeutic decisions involving patients with CUP, and we highlight areas warranting further research to engage the medical community in this unmet need.
Multi-Tasking Non-Destructive Laser Technology in Conservation Diagnostic Procedures
NASA Astrophysics Data System (ADS)
Tornari, V.; Tsiranidou, E.; Orphanos, Y.; Falldorf, C.; Klattenhof, R.; Esposito, E.; Agnani, A.; Dabu, R.; Stratan, A.; Anastassopoulos, A.; Schipper, D.; Hasperhoven, J.; Stefanaggi, M.; Bonnici, H.; Ursu, D.
Laser metrology provides techniques that have been successfully applied in industrial structural diagnostic fields but have not yet been refined and optimised for the special investigative requirements found in cultural heritage applications. A major impediment is the partial applicability of various optical coherent techniques, each one narrowing its use down to a specific application. This characteristic is not well suited for a field that encounters a great variety of diagnostic problems ranging from movable, multiple-composition museum objects, to immovable multi-layered wall paintings, statues and wood carvings, to monumental constructions and outdoor cultural heritage sites. Various diagnostic techniques have been suggested and are uniquely suited for each of the mentioned problems but it is this fragmented suitability that obstructs the technology transfer. Since optical coherent techniques for metrology are based on fundamental principles and take advantage of similar procedures for generation of informative signals for data collection, then the imposed limits elevate our aim to identify complementary capabilities to accomplish the needed functionality.
Are the classic diagnostic methods in mycology still state of the art?
Wiegand, Cornelia; Bauer, Andrea; Brasch, Jochen; Nenoff, Pietro; Schaller, Martin; Mayser, Peter; Hipler, Uta-Christina; Elsner, Peter
2016-05-01
The diagnostic workup of cutaneous fungal infections is traditionally based on microscopic KOH preparations as well as culturing of the causative organism from sample material. Another possible option is the detection of fungal elements by dermatohistology. If performed correctly, these methods are generally suitable for the diagnosis of mycoses. However, the advent of personalized medicine and the tasks arising therefrom require new procedures marked by simplicity, specificity, and swiftness. The additional use of DNA-based molecular techniques further enhances sensitivity and diagnostic specificity, and reduces the diagnostic interval to 24-48 hours, compared to weeks required for conventional mycological methods. Given the steady evolution in the field of personalized medicine, simple analytical PCR-based systems are conceivable, which allow for instant diagnosis of dermatophytes in the dermatology office (point-of-care tests). © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.
Unproven diagnostic procedures in IgE-mediated allergic diseases.
Niggemann, B; Grüber, C
2004-08-01
A considerable body of literature on therapeutic aspects of complementary and alternative medicine has been published in recent years, but little is known on diagnostic procedures. This short review lists complementary and alternative diagnostic procedures for the diagnosis of allergic diseases and presents an assessment of their usefulness for the daily practice. The review of the literature revealed that neither the determination of specific immunoglobulin G-antibodies in serum, the hair-analysis, the cytotoxic test, kinesiology, iridology, or electrodermal testing represent useful tests for the daily practice. To date, no complementary or alternative diagnostic procedure can be recommended as a meaningful element in the diagnostic work-up of allergic diseases. This is especially true for food allergy: properly performed oral food challenges still represent the gold standard for implementing specific diets in food allergic individuals. Ineffective diagnostic approaches may be costly for the consumer and delay appropriate therapy.
ERIC Educational Resources Information Center
Zhao, Zhongbao
2013-01-01
This paper aims at developing a procedural framework for the development and validation of diagnostic speaking tests. The researcher reviews the current available models of speaking performance, analyzes the distinctive features and then points out the implications for the development of a procedural framework for diagnostic speaking tests. On…
Code of Federal Regulations, 2014 CFR
2014-04-01
... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within or...
Code of Federal Regulations, 2011 CFR
2011-04-01
... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within or...
Code of Federal Regulations, 2013 CFR
2013-04-01
... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within or...
Code of Federal Regulations, 2012 CFR
2012-04-01
... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within or...
Code of Federal Regulations, 2010 CFR
2010-04-01
... shielding on patients during medical diagnostic x-ray procedures. 1000.50 Section 1000.50 Food and Drugs... shielding on patients during medical diagnostic x-ray procedures. Specific area gonad shielding covers an... that may cause genetic mutations during many medical x-ray procedures in which the gonads lie within or...
Code of Federal Regulations, 2010 CFR
2010-10-01
... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...
Code of Federal Regulations, 2011 CFR
2011-10-01
... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...
Artificially designed pathogens - a diagnostic option for future military deployments.
Zautner, Andreas E; Masanta, Wycliffe O; Hinz, Rebecca; Hagen, Ralf Matthias; Frickmann, Hagen
2015-01-01
Diagnostic microbial isolates of bio-safety levels 3 and 4 are difficult to handle in medical field camps under military deployment settings. International transport of such isolates is challenging due to restrictions by the International Air Transport Association. An alternative option might be inactivation and sequencing of the pathogen at the deployment site with subsequent sequence-based revitalization in well-equipped laboratories in the home country for further scientific assessment. A literature review was written based on a PubMed search. First described for poliovirus in 2002, de novo synthesis of pathogens based on their sequence information has become a well-established procedure in science. Successful syntheses have been demonstrated for both viruses and prokaryotes. However, the technology is not yet available for routine diagnostic purposes. Due to the potential utility of diagnostic sequencing and sequence-based de novo synthesis of pathogens, it seems worthwhile to establish the technology for diagnostic purposes over the intermediate term. This is particularly true for resource-restricted deployment settings, where safe handling of harmful pathogens cannot always be guaranteed.
Recent advances in salivary cancer diagnostics enabled by biosensors and bioelectronics.
Mishra, Saswat; Saadat, Darius; Kwon, Ohjin; Lee, Yongkuk; Choi, Woon-Seop; Kim, Jong-Hoon; Yeo, Woon-Hong
2016-07-15
There is a high demand for a non-invasive, rapid, and highly accurate tool for disease diagnostics. Recently, saliva based diagnostics for the detection of specific biomarkers has drawn significant attention since the sample extraction is simple, cost-effective, and precise. Compared to blood, saliva contains a similar variety of DNA, RNA, proteins, metabolites, and microbiota that can be compiled into a multiplex of cancer detection markers. The salivary diagnostic method holds great potential for early-stage cancer diagnostics without any complicated and expensive procedures. Here, we review various cancer biomarkers in saliva and compare the biomarkers efficacy with traditional diagnostics and state-of-the-art bioelectronics. We summarize biomarkers in four major groups: genomics, transcriptomics, proteomics, and metabolomics/microbiota. Representative bioelectronic systems for each group are summarized based on various stages of a cancer. Systematic study of oxidative stress establishes the relationship between macromolecules and cancer biomarkers in saliva. We also introduce the most recent examples of salivary diagnostic electronics based on nanotechnologies that can offer rapid, yet highly accurate detection of biomarkers. A concluding section highlights areas of opportunity in the further development and applications of these technologies. Copyright © 2016 Elsevier B.V. All rights reserved.
Martínez-Camblor, Pablo; Pardo-Fernández, Juan C
2017-01-01
Diagnostic procedures are based on establishing certain conditions and then checking if those conditions are satisfied by a given individual. When the diagnostic procedure is based on a continuous marker, this is equivalent to fix a region or classification subset and then check if the observed value of the marker belongs to that region. Receiver operating characteristic curve is a valuable and popular tool to study and compare the diagnostic ability of a given marker. Besides, the area under the receiver operating characteristic curve is frequently used as an index of the global discrimination ability. This paper revises and widens the scope of the receiver operating characteristic curve definition by setting the classification subsets in which the final decision is based in the spotlight of the analysis. We revise the definition of the receiver operating characteristic curve in terms of particular classes of classification subsets and then focus on a receiver operating characteristic curve generalization for situations in which both low and high values of the marker are associated with more probability of having the studied characteristic. Parametric and non-parametric estimators of the receiver operating characteristic curve generalization are investigated. Monte Carlo studies and real data examples illustrate their practical performance.
Siddique, Iqbal; Mohan, Krishna; Hasan, Fuad; Memon, Anjum; Patty, Istvan; Al-Nakib, Basil
2005-01-01
AIM: To assess the appropriateness of referrals and to determine the diagnostic yield of colonoscopy according to the 2000 guidelines of the American Society for Gastrointestinal Endoscopy (ASGE). METHODS: A total of 736 consecutive patients (415 males, 321 females; mean age 43.6±16.6 years) undergoing colonoscopy during October 2001-March 2002 were prospectively enrolled in the study. The 2000 ASGE guidelines were used to assess the appropriateness of the indications for the procedure. Diagnostic yield was defined as the ratio between significant findings detected on colonoscopy and the total number of procedures performed for that indication. RESULTS: The large majority (64%) of patients had colonoscopy for an indication that was considered “generally indicated”, it was “generally not indicated” for 20%, and it was “not listed” for 16% in the guidelines. The diagnostic yield of colonoscopy was highest for the “generally indicated” (38%) followed by “not listed” (13%) and “generally not indicated” (5%) categories. In the multivariable analysis, the diagnostic yield was independently associated with the appropriateness of indication that was “generally indicated” (odds ratio=12.3) and referrals by gastroenterologist (odds ratio =1.9). CONCLUSION: There is a high likelihood of inappropriate referrals for colonoscopy in an open-access endoscopy system. The diagnostic yield of the procedure is dependent on the appropriateness of indication and referring physician’s specialty. Certain indications “not listed” in the guidelines have an intermediate diagnostic yield and further studies are required to evaluate whether they should be included in future revisions of the ASGE guidelines. PMID:16437607
Diagnostic needle arthroscopy and the economics of improved diagnostic accuracy: a cost analysis.
Voigt, Jeffrey D; Mosier, Michael; Huber, Bryan
2014-10-01
Hundreds of thousands of surgical arthroscopy procedures are performed annually in the United States (US) based on MRI findings. There are situations where these MRI findings are equivocal or indeterminate and because of this clinicians commonly perform the arthroscopy in order not to miss pathology. Recently, a less invasive needle arthroscopy system has been introduced that is commonly performed in the physician office setting and that may help improve the accuracy of diagnostic findings. This in turn may prevent unnecessary follow-on arthroscopy procedures from being performed. The purpose of this analysis is to determine whether the in-office diagnostic needle arthroscopy system can provide cost savings by reducing unnecessary follow on arthroscopy procedures. Data obtained from a recent trial and from a systematic review were used in comparing the accuracy of MRI and VisionScope needle arthroscopy (VSI) with standard arthroscopy (gold standard). The resultant false positive and false negative findings were then used to evaluate the costs of follow-on procedures. These differences were then modeled for the US patient population diagnosed and treated for meniscal knee pathology (most common disorder) to determine if a technology such as VSI could save the US healthcare system money. Data on surgical arthroscopy procedures in the US for meniscal knee pathology were used (calendar year [CY] 2010). The costs of performing diagnostic and surgical arthroscopy procedures (using CY 2013 Medicare reimbursement amounts), costs associated with false negative findings, and the costs for treating associated complications arising from diagnostic and therapeutic arthroscopy procedures were assessed. In patients presenting with medial meniscal pathology (International Classification of Diseases, 9th edition, Clinical Modification [ICD9CM] diagnosis 836.0), VSI in place of MRI (standard of care) resulted in a net cost savings to the US system of US$115-US$177 million (CY 2013) (use of systematic review and study data, respectively). In patients presenting with lateral meniscus pathology (ICD9CM 836.1), VSI in place of MRI cost the healthcare system an additional US$14-US$97 million (CY 2013). Overall aggregate savings for meniscal (lateral plus medial) pathology were identified in representative care models along with more appropriate care as fewer patients were exposed to higher risk surgical procedures. Since in-office arthroscopy is significantly more accurate, patients can be treated more appropriately and the US healthcare system can save money, most especially in medial meniscal pathology.
Bissonnette, Luc; Bergeron, Michel G.
2012-01-01
Infectious disease management essentially consists in identifying the microbial cause(s) of an infection, initiating if necessary antimicrobial therapy against microbes, and controlling host reactions to infection. In clinical microbiology, the turnaround time of the diagnostic cycle (>24 hours) often leads to unnecessary suffering and deaths; approaches to relieve this burden include rapid diagnostic procedures and more efficient transmission or interpretation of molecular microbiology results. Although rapid nucleic acid-based diagnostic testing has demonstrated that it can impact on the transmission of hospital-acquired infections, we believe that such life-saving procedures should be performed closer to the patient, in dedicated 24/7 laboratories of healthcare institutions, or ideally at point of care. While personalized medicine generally aims at interrogating the genomic information of a patient, drug metabolism polymorphisms, for example, to guide drug choice and dosage, personalized medicine concepts are applicable in infectious diseases for the (rapid) identification of a disease-causing microbe and determination of its antimicrobial resistance profile, to guide an appropriate antimicrobial treatment for the proper management of the patient. The implementation of point-of-care testing for infectious diseases will require acceptance by medical authorities, new technological and communication platforms, as well as reimbursement practices such that time- and life-saving procedures become available to the largest number of patients. PMID:25562799
Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.
2014-08-21
In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and representmore » the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ–ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.« less
Research at ITER towards DEMO: Specific reactor diagnostic studies to be carried out on ITER
NASA Astrophysics Data System (ADS)
Krasilnikov, A. V.; Kaschuck, Y. A.; Vershkov, V. A.; Petrov, A. A.; Petrov, V. G.; Tugarinov, S. N.
2014-08-01
In ITER diagnostics will operate in the very hard radiation environment of fusion reactor. Extensive technology studies are carried out during development of the ITER diagnostics and procedures of their calibration and remote handling. Results of these studies and practical application of the developed diagnostics on ITER will provide the direct input to DEMO diagnostic development. The list of DEMO measurement requirements and diagnostics will be determined during ITER experiments on the bases of ITER plasma physics results and success of particular diagnostic application in reactor-like ITER plasma. Majority of ITER diagnostic already passed the conceptual design phase and represent the state of the art in fusion plasma diagnostic development. The number of related to DEMO results of ITER diagnostic studies such as design and prototype manufacture of: neutron and γ-ray diagnostics, neutral particle analyzers, optical spectroscopy including first mirror protection and cleaning technics, reflectometry, refractometry, tritium retention measurements etc. are discussed.
[Computer diagnosis of traumatic impact by hepatic lesion].
Kimbar, V I; Sevankeev, V V
2007-01-01
A method of computer-assisted diagnosis of traumatic affection by liver damage (HEPAR-test program) is described. The program is based on calculated diagnostic coefficients using Bayes' probability method with Wald's recognition procedure.
... used for teaching, modeling radiation absorption and therapy, equipment design, surgical simulation, and simulation of diagnostic procedures, ….” ... Project ® " by Michael J. Ackerman, Ph.D. Projects Based on the Visible Human Data Set Applications for ...
[Clinical use of interventional MR imaging].
Kahn, Thomas; Schulz, Thomas; Moche, Michael; Prothmann, Sascha; Schneider, Jens-Peter
2003-01-01
The integration of diagnostic and therapeutic procedures by MRI is based on the combination of excellent morphologic and functional imaging. The spectrum of MR-guided interventions includes biopsies, thermal ablation procedures, vascular applications, and intraoperative MRI. In all these applications, different scientific groups have obtained convincing results in basic developments as well as in clinical use. Interventional MRI (iMRI) is expected to attain an important role in interventional radiology, minimal invasive therapy, and monitoring of surgical procedures.
Next generation diagnostic molecular pathology: critical appraisal of quality assurance in Europe.
Dubbink, Hendrikus J; Deans, Zandra C; Tops, Bastiaan B J; van Kemenade, Folkert J; Koljenović, S; van Krieken, Han J M; Blokx, Willeke A M; Dinjens, Winand N M; Groenen, Patricia J T A
2014-06-01
Tumor evaluation in pathology is more and more based on a combination of traditional histopathology and molecular analysis. Due to the rapid development of new cancer treatments that specifically target aberrant proteins present in tumor cells, treatment decisions are increasingly based on the molecular features of the tumor. Not only the number of patients eligible for targeted precision medicine, but also the number of molecular targets per patient and tumor type is rising. Diagnostic molecular pathology, the discipline that determines the molecular aberrations present in tumors for diagnostic, prognostic or predictive purposes, is faced with true challenges. The laboratories have to meet the need of comprehensive molecular testing using only limited amount of tumor tissue, mostly fixed in formalin and embedded in paraffin (FFPE), in short turnaround time. Choices must be made for analytical methods that provide accurate, reliable and cost-effective results. Validation of the test procedures and results is essential. In addition, participation and good performance in internal (IQA) and external quality assurance (EQA) schemes is mandatory. In this review, we critically evaluate the validation procedure for comprehensive molecular tests as well as the organization of quality assurance and assessment of competence of diagnostic molecular pathology laboratories within Europe. Copyright © 2014 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.
Antonelli, Giorgia; Padoan, Andrea; Aita, Ada; Sciacovelli, Laura; Plebani, Mario
2017-08-28
Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements.
Navarrete-Dechent, Cristián; Bajaj, Shirin; Marghoob, Ashfaq A; Marchetti, Michael A
2015-06-01
Dermatophytoses are common skin infections. Traditional diagnostic tests such as skin scrapings for light microscopy examination, fungal cultures and biopsies remain imperfect due to false-negative test results, cost, time required to perform the procedure, time delays in test results and/or a requirement for an invasive procedure. Herein, we present a case of an 80-year-old female whose tinea incognito was non-invasively diagnosed within seconds using handheld reflectance confocal microscopy (RCM). As non-invasive skin imaging continues to improve, we expect light-based office microscopy to be replaced with technologies such as RCM, which has multiple and continually expanding diagnostic applications. © 2015 Blackwell Verlag GmbH.
Lopes, Antonio Augusto; Barst, Robyn J; Haworth, Sheila Glennis; Rabinovitch, Marlene; Al Dabbagh, Maha; Del Cerro, Maria Jesus; Ivy, Dunbar; Kashour, Tarek; Kumar, Krishna; Harikrishnan, S; D'Alto, Michele; Thomaz, Ana Maria; Zorzanelli, Leína; Aiello, Vera D; Mocumbi, Ana Olga; Santana, Maria Virginia T; Galal, Ahmed Nasser; Banjar, Hanaa; Tamimi, Omar; Heath, Alexandra; Flores, Patricia C; Diaz, Gabriel; Sandoval, Julio; Kothari, Shyam; Moledina, Shahin; Gonçalves, Rilvani C; Barreto, Alessandra C; Binotto, Maria Angélica; Maia, Margarida; Al Habshan, Fahad; Adatia, Ian
2014-06-01
Standardization of the diagnostic routine for children with congenital heart disease associated with pulmonary arterial hypertension (PAH-CHD) is crucial, in particular since inappropriate assignment to repair of the cardiac lesions (e.g., surgical repair in patients with elevated pulmonary vascular resistance) may be detrimental and associated with poor outcomes. Thus, members of the Congenital Heart Disease and Pediatric Task Forces of the Pulmonary Vascular Research Institute decided to conduct a survey aimed at collecting expert opinion from different institutions in several countries, covering many aspects of the management of PAH-CHD, from clinical recognition to noninvasive and invasive diagnostic procedures and immediate postoperative support. In privileged communities, the vast majority of children with congenital cardiac shunts are now treated early in life, on the basis of noninvasive diagnostic evaluation, and have an uneventful postoperative course, with no residual PAH. However, a small percentage of patients (older at presentation, with extracardiac syndromes or absence of clinical features of increased pulmonary blood flow, thus suggesting elevated pulmonary vascular resistance) remain at a higher risk of complications and unfavorable outcomes. These patients need a more sophisticated diagnostic approach, including invasive procedures. The authors emphasize that decision making regarding operability is based not only on cardiac catheterization data but also on the complete diagnostic picture, which includes the clinical history, physical examination, and all aspects of noninvasive evaluation.
Value of percutaneous needle biopsy of small renal tumors in patients referred for cryoablation.
Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Sakurai, Jun; Matsui, Yusuke; Araki, Motoo; Nasu, Yasutomo; Kanazawa, Susumu
2017-04-01
To retrospectively evaluate the safety and diagnostic yield of needle biopsy of small renal tumors, and the clinical consequences of performing needle biopsy in patients referred for percutaneous cryoablation before their treatment. Biopsy was performed for 120 tumors (mean diameter, 2.2 cm) in 119 patients. All procedures were divided into diagnostic and non-diagnostic biopsies. Various variables were compared between the two groups. All cryoablation procedures were divided into two groups: procedures with or without simultaneous biopsy. The rates of benign or non-diagnostic tumors in each group were compared. After performing 120 initial and eight repeat biopsies, Grade 1 bleedings occurred in 44 cases. Six tumors were non-diagnostic and 114 were pathologically diagnosed. There were no significant variables between the diagnostic and non-diagnostic biopsies. Unnecessary cryoablation was avoided in nine benign lesions by performing biopsy in advance. Cryoablation performed simultaneously with biopsy included significantly more benign or non-diagnostic tumors than cryoablation performed after biopsy (15.2% vs. 1.4%; p = .01). Percutaneous biopsy of small renal tumors referred for cryoablation was a safe procedure with high diagnostic yield. The confirmation of pathological diagnosis prior to cryoablation is necessary because patients with benign tumors can avoid unnecessary treatment.
Hahn, Jessica; Lessard, Darleen; Yarzebski, Jorge; Goldberg, Jordan; Pruell, Sean; Spencer, Frederick A.; Gore, Joel M.; Goldberg, Robert J.
2007-01-01
Background Limited data are available describing contemporary trends in the utilization of diagnostic and interventional procedures in patients hospitalized with acute myocardial infarction (AMI). The objectives of our population-based investigation were to examine long-term trends (1986–2003) in the utilization of cardiac catheterization, percutaneous coronary interventions (PCI), and coronary artery bypass graft surgery (CABG) in a community sample of patients hospitalized with AMI. We examined the demographic and clinical characteristics of patients who received these diagnostic and interventional procedures and determined whether the profile of patients undergoing these procedures had changed over time. Methods The study sample consisted of 9,422 greater Worcester (MA) residents hospitalized with confirmed AMI at all metropolitan Worcester medical centers in 10 annual periods between 1986 and 2003. Information on patient demographics, clinical course, and treatment practices was obtained through the review of hospital medical records. Results Marked increases were observed in the utilization of cardiac catheterization (18.4% to 55.8%) and PCI (2.0% to 42.1%) between 1986 and 2003, respectively. Utilization of CABG showed modest increases in the early 1990's while its use was relatively stable thereafter. Several demographic and clinical characteristics were associated with the receipt of these diagnostic and interventional procedures. Conclusions The results of this study of patients hospitalized with AMI in a large Northeast community suggest evolving trends in the use of cardiac catheterization, PCI, and CABG. Despite these changing patterns, our findings suggest that there remains room for improvement in the therapeutic management of patients hospitalized with AMI, including certain high risk groups. PMID:17383299
Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions
Khosla, Rahul; McLean, Anna W; Smith, Jessica A
2016-01-01
Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440
Duval, Kristin; Aubin, Rémy A; Elliott, James; Gorn-Hondermann, Ivan; Birnboim, H Chaim; Jonker, Derek; Fourney, Ron M; Frégeau, Chantal J
2010-02-01
Archival tissue preserved in fixative constitutes an invaluable resource for histological examination, molecular diagnostic procedures and for DNA typing analysis in forensic investigations. However, available material is often limited in size and quantity. Moreover, recovery of DNA is often severely compromised by the presence of covalent DNA-protein cross-links generated by formalin, the most prevalent fixative. We describe the evaluation of buffer formulations, sample lysis regimens and DNA recovery strategies and define optimized manual and automated procedures for the extraction of high quality DNA suitable for molecular diagnostics and genotyping. Using a 3-step enzymatic digestion protocol carried out in the absence of dithiothreitol, we demonstrate that DNA can be efficiently released from cells or tissues preserved in buffered formalin or the alcohol-based fixative GenoFix. This preparatory procedure can then be integrated to traditional phenol/chloroform extraction, a modified manual DNA IQ or automated DNA IQ/Te-Shake-based extraction in order to recover DNA for downstream applications. Quantitative recovery of high quality DNA was best achieved from specimens archived in GenoFix and extracted using magnetic bead capture.
Pediatric radiological diagnostic procedures in cases of suspected child abuse.
Erfurt, C; Hahn, G; Roesner, D; Schmidt, U
2011-03-01
Advanced and specialized radiological diagnostic procedures are essential in cases of clinically diagnosed injuries to the head, thorax, abdomen or extremities of a child, especially if there is no case history or if the reporting of an inadequate trauma suggests battered child syndrome. In particular, these diagnostic procedures should aim at detecting lesions of the central nervous system (CNS), so that the treatment can be immediately initiated. If the diagnostic imaging reveals findings typically associated with child abuse, accurate documentation constituting evidence, which will stand up in court, is required to prevent any further endangerment of the child's welfare.
NASA Technical Reports Server (NTRS)
Stephan, Amy; Erikson, Carol A.
1991-01-01
As an initial attempt to introduce expert system technology into an onboard environment, a model based diagnostic system using the TRW MARPLE software tool was integrated with prototype flight hardware and its corresponding control software. Because this experiment was designed primarily to test the effectiveness of the model based reasoning technique used, the expert system ran on a separate hardware platform, and interactions between the control software and the model based diagnostics were limited. While this project met its objective of showing that model based reasoning can effectively isolate failures in flight hardware, it also identified the need for an integrated development path for expert system and control software for onboard applications. In developing expert systems that are ready for flight, artificial intelligence techniques must be evaluated to determine whether they offer a real advantage onboard, identify which diagnostic functions should be performed by the expert systems and which are better left to the procedural software, and work closely with both the hardware and the software developers from the beginning of a project to produce a well designed and thoroughly integrated application.
Deletion Diagnostics for the Generalised Linear Mixed Model with independent random effects
Ganguli, B.; Roy, S. Sen; Naskar, M.; Malloy, E. J.; Eisen, E. A.
2015-01-01
The Generalised Linear Mixed Model (GLMM) is widely used for modelling environmental data. However, such data are prone to influential observations which can distort the estimated exposure-response curve particularly in regions of high exposure. Deletion diagnostics for iterative estimation schemes commonly derive the deleted estimates based on a single iteration of the full system holding certain pivotal quantities such as the information matrix to be constant. In this paper, we present an approximate formula for the deleted estimates and Cook’s distance for the GLMM which does not assume that the estimates of variance parameters are unaffected by deletion. The procedure allows the user to calculate standardised DFBETAs for mean as well as variance parameters. In certain cases, such as when using the GLMM as a device for smoothing, such residuals for the variance parameters are interesting in their own right. In general, the procedure leads to deleted estimates of mean parameters which are corrected for the effect of deletion on variance components as estimation of the two sets of parameters is interdependent. The probabilistic behaviour of these residuals is investigated and a simulation based procedure suggested for their standardisation. The method is used to identify influential individuals in an occupational cohort exposed to silica. The results show that failure to conduct post model fitting diagnostics for variance components can lead to erroneous conclusions about the fitted curve and unstable confidence intervals. PMID:26626135
Conwell, Darwin L.; Lee, Linda S.; Yadav, Dhiraj; Longnecker, Daniel S.; Miller, Frank H.; Mortele, Koenraad J.; Levy, Michael J.; Kwon, Richard; Lieb, John G.; Stevens, Tyler; Toskes, Philip P.; Gardner, Timothy B.; Gelrud, Andres; Wu, Bechien U.; Forsmark, Christopher E.; Vege, Santhi S.
2016-01-01
The diagnosis of chronic pancreatitis remains challenging in early stages of the disease. This report defines the diagnostic criteria useful in the assessment of patients with suspected and established chronic pancreatitis. All current diagnostic procedures are reviewed and evidence based statements are provided about their utility and limitations. Diagnostic criteria for chronic pancreatitis are classified as definitive, probable or insufficient evidence. A diagnostic (STEP-wise; S-survey, T-tomography, E-endoscopy and P-pancreas function testing) algorithm is proposed that proceeds from a non-invasive to a more invasive approach. This algorithm maximizes specificity (low false positive rate) in subjects with chronic abdominal pain and equivocal imaging changes. Futhermore, a nomenclature is suggested to further characterize patients with established chronic pancreatitis based on TIGAR-O (T-toxic, I-idiopathic, G-genetic, A- autoimmune, R-recurrent and O-obstructive) etiology, gland morphology (Cambridge criteria) and physiologic state (exocrine, endocrine function) for uniformity across future multi-center research collaborations. This guideline will serve as a baseline manuscript that will be modified as new evidence becomes available and our knowledge of chronic pancreatitis improves. PMID:25333398
2014-01-01
Background The purpose of this analysis was to determine whether in office diagnostic needle arthroscopy (Visionscope Imaging System [VSI]) can provide for improved diagnostic assessment and; more cost effective care. Methods Data on arthroscopy procedures in the US for deep seated pathology in the knee and shoulder were used (Calendar Year 2012). These procedures represent approximately 25-30% of all arthroscopic procedures performed annually. Sensitivities, specificities, positive predictive, and negative predictive values for MRI analysis of this deep seated pathology from systematic reviews and meta-analyses were used in assessing for false positive and false negative MRI findings. The costs of performing diagnostic and surgical arthroscopy procedures (using 2013 Medicare reimbursement amounts); costs associated with false negative findings; and the costs for treating associated complications arising from diagnostic and therapeutic arthroscopy procedures were then assessed. Results In patients presenting with medial meniscal pathology (ICD9CM diagnosis 836.0 over 540,000 procedures in CY 2012); use of the VSI system in place of MRI assessment (standard of care) resulted in a net cost savings to the system of $151 million. In patients presenting with rotator cuff pathology (ICD9CM 840.4 over 165,000 procedures in CY2012); use of VSI in place of MRI similarly saved $59 million. These savings were realized along with more appropriate care as; fewer patients were exposed to higher risk surgical arthroscopic procedures. Conclusions The use of an in-office arthroscopy system can: possibly save the US healthcare system money; shorten the diagnostic odyssey for patients; potentially better prepare clinicians for arthroscopic surgery (when needed) and; eliminate unnecessary outpatient arthroscopy procedures, which commonly result in surgical intervention. PMID:24885678
Krolewiecki, Alejandro J; Koukounari, Artemis; Romano, Miryam; Caro, Reynaldo N; Scott, Alan L; Fleitas, Pedro; Cimino, Ruben; Shiff, Clive J
2018-06-01
For epidemiological work with soil transmitted helminths the recommended diagnostic approaches are to examine fecal samples for microscopic evidence of the parasite. In addition to several logistical and processing issues, traditional diagnostic approaches have been shown to lack the sensitivity required to reliably identify patients harboring low-level infections such as those associated with effective mass drug intervention programs. In this context, there is a need to rethink the approaches used for helminth diagnostics. Serological methods are now in use, however these tests are indirect and depend on individual immune responses, exposure patterns and the nature of the antigen. However, it has been demonstrated that cell-free DNA from pathogens and cancers can be readily detected in patient's urine which can be collected in the field, filtered in situ and processed later for analysis. In the work presented here, we employ three diagnostic procedures-stool examination, serology (NIE-ELISA) and PCR-based amplification of parasite transrenal DNA from urine-to determine their relative utility in the diagnosis of S. stercoralis infections from 359 field samples from an endemic area of Argentina. Bayesian Latent Class analysis was used to assess the relative performance of the three diagnostic procedures. The results underscore the low sensitivity of stool examination and support the idea that the use of serology combined with parasite transrenal DNA detection may be a useful strategy for sensitive and specific detection of low-level strongyloidiasis.
9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Procedures for preparing egg yolk... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... chapter. (a) Under the supervision of an Authorized Agent or State Inspector, the eggs which are used in...
20 CFR 404.1519m - Diagnostic tests or procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... DISABILITY INSURANCE (1950- ) Determining Disability and Blindness Standards for the Type of Referral and for Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic..., arteriograms, or cardiac catheterizations for the evaluation of disability under the Social Security program. A...
Emergency Kausch-Whipple procedure: indications and experiences.
Standop, Jens; Glowka, Tim; Schmitz, Volker; Schaefer, Nico; Hirner, Andreas; Kalff, Jörg C
2010-03-01
Pancreaticoduodenectomy is a demanding procedure even in selected patients but becomes formidable when performed in cases of emergency. This study analyzed our experience with urgent pancreatoduodenectomies; special emphases were put on the evaluation of diagnostic means and the validation of existing indications for performance of this procedure. Three hundred one patients who underwent pancreatoduodenectomy between 1989 and 2008 were identified from a pancreatic resection database and reviewed for emergency indications. Six patients (2%) underwent emergency pancreatoduodenectomy. Indications included endoscopy-related perforation, postoperative complications, and uncontrollable intraduodenal tumor bleeding. Length of stay and occurrence of nonsurgical complications were increased in emergency compared with elective pancreatoduodenectomies. Although increased, no significant differences were found regarding mortality and surgery-related complications. Indications for emergency pancreatoduodenectomies were based on clinical decisions rather than on radiologic diagnostics. Urgent pancreatic head resections may be considered as an option in selected patients if handling of local complications by interventional measures or limited surgery seems unsafe.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1986-01-01
This symposium presented the latest techniques and approaches to the proper medical application of radionuclides in pediatrics. An expert faculty, comprised of specialists in the field of pediatric nuclear medicine, discussed the major indications as well as the advantages and potential hazards of nuclear medicine procedures compared to other diagnostic modalities. In recent years, newer radiopharmaceuticals labeled with technetium-99m and other short-lived radionuclides with relatively favorable radiation characteristics have permitted a variety of diagnostic studies that are very useful clinically and carry a substantially lower radiation burden then many comparable X-ray studies. This new battery of nuclear medicine procedures ismore » now widely available for diagnosis and management of pediatric patients. Many recent research studies in children have yielded data concerning the effacacy of these procedures, and current recommendations will be presented by those involved in conducting such studies. Individual papers are processed separately for the Energy Data Base.« less
Viezzer, E; Dux, R; Dunne, M G
2016-11-01
A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line D α . The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viezzer, E., E-mail: eleonora.viezzer@ipp.mpg.de, E-mail: eviezzer@us.es; Department of Atomic, Molecular, and Nuclear Physics, University of Seville, Avda. Reina Mercedes, 41012 Seville; Dux, R.
2016-11-15
A new edge beam emission polarimetry diagnostic dedicated to the measurement of the magnetic field line angle has been installed on the ASDEX Upgrade tokamak. The new diagnostic relies on the motional Stark effect and is based on the simultaneous measurement of the polarization direction of the linearly polarized π (parallel to the electric field) and σ (perpendicular to the electric field) lines of the Balmer line D{sub α}. The technical properties of the system are described. The calibration procedures are discussed and first measurements are presented.
Designing a training tool for imaging mental models
NASA Technical Reports Server (NTRS)
Dede, Christopher J.; Jayaram, Geetha
1990-01-01
The training process can be conceptualized as the student acquiring an evolutionary sequence of classification-problem solving mental models. For example a physician learns (1) classification systems for patient symptoms, diagnostic procedures, diseases, and therapeutic interventions and (2) interrelationships among these classifications (e.g., how to use diagnostic procedures to collect data about a patient's symptoms in order to identify the disease so that therapeutic measures can be taken. This project developed functional specifications for a computer-based tool, Mental Link, that allows the evaluative imaging of such mental models. The fundamental design approach underlying this representational medium is traversal of virtual cognition space. Typically intangible cognitive entities and links among them are visible as a three-dimensional web that represents a knowledge structure. The tool has a high degree of flexibility and customizability to allow extension to other types of uses, such a front-end to an intelligent tutoring system, knowledge base, hypermedia system, or semantic network.
Hao, Shuang; Liu, Zhe-Bin; Ling, Hong; Chen, Jia-Jian; Shen, Ju-Ping; Yang, Wen-Tao; Shao, Zhi-Min
2015-01-01
Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were selected from the Shanghai Cancer Data base, which integrates information from approximately 50% of breast cancer patients in Shanghai. The CNB procedure uses an automated prone unit, biopsy gun, and 14-gauge needles under freehand or ultrasound guidance and was performed by experienced radiologists and surgeons specializing in needle biopsies. Diagnosis and classification for each patient were independently evaluated by pathologists. Over the indicated 8-year period, biopsy type consisted of 11,947 ultrasound-guided core needle biopsies (UCNBs), 2,015 ultrasound-guided vacuum-assisted biopsies (UVABs), and 654 stereotactic X-ray-guided vacuum-assisted biopsies (XVABs). For all the 11,947 women included in this study, image-guided needle biopsy was the initial diagnostic procedure. Approximately 81.0% of biopsied samples were histopathologically determined to be malignant lesions, 5.5% were determined to be high-risk lesions, and 13.5% were determined to be benign lesions. The number of patients choosing UCNB increased at the greatest rate, and UCNB has become a standard procedure for histodiagnosis because it is inexpensive, convenient, and accurate. The overall false-negative rate of CNB was 1.7%, and the specific false-negative rates for UCNB, UVAB, and XVAB, were 1.7%, 0%, and 0%, respectively. This study suggests that the use of preoperative needle biopsy as the initial breast cancer diagnostic procedure is acceptable in urban Shanghai. Preoperative needle biopsy is now a standard procedure in the Shanghai Cancer Center because it may reduce the number of surgeries needed to treat breast cancer. PMID:26491359
Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics
NASA Technical Reports Server (NTRS)
Sowers, T. Shane; Kopasakis, George; Simon, Donald L.
2008-01-01
The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance, there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight, and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.
Application of the Systematic Sensor Selection Strategy for Turbofan Engine Diagnostics
NASA Technical Reports Server (NTRS)
Sowers, T. Shane; Kopasakis, George; Simon, Donald L.
2008-01-01
The data acquired from available system sensors forms the foundation upon which any health management system is based, and the available sensor suite directly impacts the overall diagnostic performance that can be achieved. While additional sensors may provide improved fault diagnostic performance there are other factors that also need to be considered such as instrumentation cost, weight, and reliability. A systematic sensor selection approach is desired to perform sensor selection from a holistic system-level perspective as opposed to performing decisions in an ad hoc or heuristic fashion. The Systematic Sensor Selection Strategy is a methodology that optimally selects a sensor suite from a pool of sensors based on the system fault diagnostic approach, with the ability of taking cost, weight and reliability into consideration. This procedure was applied to a large commercial turbofan engine simulation. In this initial study, sensor suites tailored for improved diagnostic performance are constructed from a prescribed collection of candidate sensors. The diagnostic performance of the best performing sensor suites in terms of fault detection and identification are demonstrated, with a discussion of the results and implications for future research.
Diagnostic challenges of childhood asthma.
Bakirtas, Arzu
2017-01-01
Diagnosis of asthma in childhood is challenging. Both underdiagnosis and overdiagnosis of asthma are important issues. The present review gives information about challenging factors for an accurate diagnosis of childhood asthma. Although underdiagnosis of asthma in childhood has always been the most important diagnostic problem, overdiagnosis of asthma has also been increasingly recognized. This is probably due to diagnosis of asthma based on symptoms and signs alone. Demonstration of variable airflow obstruction by lung function tests is the most common asthma diagnostic tests used in practice and is therefore strongly recommended in children who can cooperate. Recently, an asthma guideline combining the clinical and economic evidences with sensitivity and specificity of diagnostic procedures was developed to improve accuracy of diagnosis and to avoid overdiagnosis. This guideline provided an algorithmic clinical and cost-effective approach and included fractional exhaled nitric oxide measurement as one of the diagnostic tests in addition to lung function. Diagnosis of asthma in children should be made by combining relevant history with at least two confirmatory diagnostic tests whenever possible. Diagnosis based on short-period treatment trials should be limited to young children who are unable to cooperate with these tests.
Fetal and maternal dose assessment for diagnostic scans during pregnancy
NASA Astrophysics Data System (ADS)
Rafat Motavalli, Laleh; Miri Hakimabad, Hashem; Hoseinian Azghadi, Elie
2016-05-01
Despite the concerns about prenatal exposure to ionizing radiation, the number of nuclear medicine examinations performed for pregnant women increased in the past decade. This study attempts to better quantify radiation doses due to diagnostic nuclear medicine procedures during pregnancy with the help of our recently developed 3, 6, and 9 month pregnant hybrid phantoms. The reference pregnant models represent the adult female international commission on radiological protection (ICRP) reference phantom as a base template with a fetus in her gravid uterus. Six diagnostic scintigraphy scans using different radiopharmaceuticals were selected as typical diagnostic nuclear medicine procedures. Furthermore, the biokinetic data of radioiodine was updated in this study. A compartment representing iodide in fetal thyroid was addressed explicitly in the biokinetic model. Calculations were performed using the Monte Carlo transport method. Tabulated dose coefficients for both maternal and fetal organs are provided. The comparison was made with the previously published fetal doses calculated for stylized pregnant female phantoms. In general, the fetal dose in previous studies suffers from an underestimation of up to 100% compared to fetal dose at organ level in this study. A maximum of difference in dose was observed for the fetal thyroid compared to the previous studies, in which the traditional models did not contain the fetal thyroid. Cumulated activities of major source organs are primarily responsible for the discrepancies in the organ doses. The differences in fetal dose depend on several other factors including chord length distribution between fetal organs and maternal major source organs, and anatomical differences according to gestation periods. Finally, considering the results of this study, which was based on the realistic pregnant female phantoms, a more informed evaluation of the risks and benefits of the different procedures could be made.
Van Dyke, Miriam E.; Drozdovitch, Vladimir; Doody, Michele M.; Lim, Hyeyeun; Bolus, Norman E.; Simon, Steven L.; Alexander, Bruce H.; Kitahara, Cari M.
2016-01-01
We evaluated historical patterns in the types of procedures performed in diagnostic and therapeutic nuclear medicine and the associated radiation safety practices used from 1945–2009 in a sample of U.S. radiologic technologists. In 2013–2014, 4,406 participants from the U.S. Radiologic Technologists (USRT) Study who previously reported working with medical radionuclides completed a detailed survey inquiring about the performance of 23 diagnostic and therapeutic radionuclide procedures and the use of radiation safety practices when performing radionuclide procedure-related tasks during five time periods: 1945–1964, 1965–1979, 1980–1989, 1990–1999, and 2000–2009. We observed an overall increase in the proportion of technologists who performed specific diagnostic or therapeutic procedures across the five time periods. Between 1945–1964 and 2000–2009, the median frequency of diagnostic procedures performed substantially increased (5 per week to 30 per week), attributable mainly to an increasing frequency of cardiac and non-brain PET scans, while the median frequency of therapeutic procedures performed modestly decreased (from 4 per month to 3 per month). We also observed a notable increase in the use of most radiation safety practices from 1945–1964 to 2000–2009 (e.g., use of lead-shielded vials during diagnostic radiopharmaceutical preparation increased from 56 to 96%), although lead apron use dramatically decreased (e.g., during diagnostic imaging procedures, from 81 to 7%). These data describe historical practices in nuclear medicine and can be used to support studies of health risks in nuclear medicine technologists. PMID:27218293
Cost-Effectiveness Analysis of Diagnostic Options for Pneumocystis Pneumonia (PCP)
Harris, Julie R.; Marston, Barbara J.; Sangrujee, Nalinee; DuPlessis, Desiree; Park, Benjamin
2011-01-01
Background Diagnosis of Pneumocystis jirovecii pneumonia (PCP) is challenging, particularly in developing countries. Highly sensitive diagnostic methods are costly, while less expensive methods often lack sensitivity or specificity. Cost-effectiveness comparisons of the various diagnostic options have not been presented. Methods and Findings We compared cost-effectiveness, as measured by cost per life-years gained and proportion of patients successfully diagnosed and treated, of 33 PCP diagnostic options, involving combinations of specimen collection methods [oral washes, induced and expectorated sputum, and bronchoalveolar lavage (BAL)] and laboratory diagnostic procedures [various staining procedures or polymerase chain reactions (PCR)], or clinical diagnosis with chest x-ray alone. Our analyses were conducted from the perspective of the government payer among ambulatory, HIV-infected patients with symptoms of pneumonia presenting to HIV clinics and hospitals in South Africa. Costing data were obtained from the National Institutes of Communicable Diseases in South Africa. At 50% disease prevalence, diagnostic procedures involving expectorated sputum with any PCR method, or induced sputum with nested or real-time PCR, were all highly cost-effective, successfully treating 77–90% of patients at $26–51 per life-year gained. Procedures using BAL specimens were significantly more expensive without added benefit, successfully treating 68–90% of patients at costs of $189–232 per life-year gained. A relatively cost-effective diagnostic procedure that did not require PCR was Toluidine Blue O staining of induced sputum ($25 per life-year gained, successfully treating 68% of patients). Diagnosis using chest x-rays alone resulted in successful treatment of 77% of patients, though cost-effectiveness was reduced ($109 per life-year gained) compared with several molecular diagnostic options. Conclusions For diagnosis of PCP, use of PCR technologies, when combined with less-invasive patient specimens such as expectorated or induced sputum, represent more cost-effective options than any diagnostic procedure using BAL, or chest x-ray alone. PMID:21858013
Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu
2018-01-01
To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.
Code of Federal Regulations, 2011 CFR
2011-01-01
.... W., Jr., “Mycoplasmosis.” In: Isolation and Identification of Avian Pathogens. (Stephen B. Hitchner... Scientific Company. (4) Mycoplasma Broth Base, dextrose, phenol red, and cysteine hydrochloride are added to... Mycoplasma Broth Base may be obtained from: (a) Product #M 33600, Gibco Diagnostics, 2801 Industrial Drive...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, J.L.; Krieger, M.J.
This paper is about the economic evaluation of diagnostic procedures. The issue of economic evaluation is explored in the context of four common diagnostic X-ray procedures: the chest X-ray, the skull X-ray, the barium enema study, and the excretory urogram. The paper is divided into two parts. The first part summarizes the different evaluative models underlying studies of the four diagnostic X-ray procedures and to lay out the strengths and weaknesses of each method. The second part contains four separate chapters summarizing what is known about the utilization, costs, risks, and benefits of each procedure, with particular emphasis on themore » evaluative methods employed.« less
To fine needle aspiration or not? An endosonographer's approach to pancreatic cystic lesions
But, David Yiu-Kuen; Poley, Jan-Werner
2014-01-01
Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is an established diagnostic tool in the management of pancreatic cystic lesions (PCLs). Due to the proximity to the target lesion, the fine diagnostic needle travels through only minimal normal tissues. The risks of bleeding, pancreatitis and infection are small. Valuable diagnostic morphological information can be obtained by EUS before the use of FNA. The additional cytopathologic and cyst fluid analysis for the conventional markers such as amylase, carcinoembryonic antigen (CEA) and CA19.9 improves the diagnostic capability. Pancreatic cyst fluid CEA concentration of 192 ng/mL is generally the most agreed cutoff to differentiate mucinous from non-mucinous lesion. A fluid amylase level of <250 IU/L excludes the diagnosis of pseudocyst. Technical tips of EUS-FNA and the limitations of the procedure are discussed. Promising technique and FNA needle modifications have been described to improve the diagnostic yield at the cytopathologic analysis. The use of novel cyst fluid proteomics and deoxyribonucleic acid-based biomarkers of the PCLs are reviewed. Although it is considered a safe procedure, EUS-FNA is not a routine in every patient. Recommendations of the role of EUS-FNA at various common clinical scenarios are discussed. PMID:24955337
Kasasbeh, Ehab S; Parvez, Babar; Huang, Robert L; Hasselblad, Michele Marie; Glazer, Mark D; Salloum, Joseph G; Cleator, John H; Zhao, David X
2012-11-01
To determine whether radial artery access is associated with a reduction in fluoroscopy time, procedure time, and other procedural variables over a 27-month period during which the radial artery approach was incorporated in a single academic Medical Center. Although previous studies have demonstrated a relationship between increased volume and decreased procedural time, no studies have looked at the integration of radial access over time. Data were collected from consecutive patients who presented to the Vanderbilt University Medical Center cardiac catheterization laboratory from January 1, 2009 to April 1, 2011. Patients who underwent radial access diagnostic catheterization with and without percutaneous coronary intervention were included in this study. A total of 1112 diagnostic cardiac catheterizations through the radial access site were analyzed. High-volume, intermediate-volume, and low-volume operators were grouped based on the percentage of procedures performed through a radial approach. From 2009 to 2011, there was a significant decrease in fluoroscopy time in all operator groups for diagnostic catheterization (P=.035). The high-volume operator group had 1.88 and 3.66 minute reductions in fluoroscopy time compared to the intermediate- and low-volume operator groups, respectively (both P<.001). Likewise, the intermediate-volume operator group had a 1.77 minute improvement compared to the low-volume operator group, but this did not reach statistical significance (P=.102). The improvement in fluoroscopy time and other procedure-related parameters was seen after approximately 25 cases with further improvement after 75 cases. The incorporation of the radial access approach in the cardiac catheterization laboratory led to a decrease in fluoroscopy time for each operator and operator group over the last 3 years. Our data demonstrated that higher-volume radial operators have better procedure, room, and fluoroscopy times when compared to intermediate- and low-volume operators. However, lower-volume operators have a reduction in procedure-related parameters with increased radial cases. Number of procedures needed to become sufficient was demonstrated in the current study.
Efficiency of Core Biopsy for BI-RADS-5 Breast Lesions.
Wolf, Ronald; Quan, Glenda; Calhoun, Kris; Soot, Laurel; Skokan, Laurie
2008-01-01
Stereotactic biopsy has proven more cost effective for biopsy of lesions associated with moderately suspicious mammograms. Data regarding selection of stereotactic biopsy (CORE) instead of excisional biopsy (EB) as the first diagnostic procedure in patients with nonpalpable breast lesions and highest suspicion breast imaging-reporting and data system (BI-RADS)-5 mammograms are sparse. Records from a regional health system radiology database were screened for mammograms associated with image-guided biopsy. A total of 182 nonpalpable BI-RADS-5 lesions were sampled in 178 patients over 5 years, using CORE or EB. Initial surgical margins, number of surgeries, time from initial procedure to last related surgical procedure, and hospital and professional charges for related admissions were compared using chi-squared, t-test, and Wilcoxon Mann-Whitney tests. A total of 108 CORE and 74 EB were performed as the first diagnostic procedure. Invasive or in situ carcinoma was diagnosed in 156 (86%) of all biopsies, 95 in CORE and 61 in EB groups. Negative margins of the first surgical procedure were more frequent in CORE (n = 70, 74%) versus EB (n = 17, 28%), p < 0.05. Use of CORE was associated with fewer total surgical procedures per lesion (1.29 +/- 0.05 versus 1.8 +/- 0.05, p < 0.05). Time of initial diagnostic procedure to final treatment did not vary significantly according to group (27 +/- 2 days versus 22 +/- 2 days, CORE versus EB). Mean charges including the diagnostic procedure and all subsequent surgeries were not different between CORE and EB groups ($10,500 +/- 300 versus $11,500 +/- 500, p = 0.08). Use of CORE as the first procedure in patients with highly suspicious mammograms is associated with improved pathologic margins and need for fewer surgical procedures than EB, and should be considered the preferred initial diagnostic approach.
NASA Astrophysics Data System (ADS)
Ngaile, J. E.; Msaki, P. K.; Kazema, R. R.
2018-04-01
Contrast investigations of hysterosalpingography (HSG) and retrograde urethrography (RUG) fluoroscopy procedures remain the dominant diagnostic tools for the investigation of infertility in females and urethral strictures in males, respectively, owing to the scarcity and high cost of services of alternative diagnostic technologies. In light of the radiological risks associated with contrast based investigations of the genitourinary tract systems, there is a need to assess the magnitude of radiation burden imparted to patients undergoing HSG and RUG fluoroscopy procedures in Tanzania. The air kerma area product (KAP), fluoroscopy time, number of images, organ dose and effective dose to patients undergoing HSG and RUG procedures were obtained from four hospitals. The KAP was measured using a flat transmission ionization chamber, while the organ and effective doses were estimated using the knowledge of the patient characteristics, patient related exposure parameters, geometry of examination, KAP and Monte Carlo calculations (PCXMC). The median values of KAP for the HSG and RUG were 2.2 Gy cm2 and 3.3 Gy cm2, respectively. The median organ doses in the present study for the ovaries, urinary bladder and uterus for the HSG procedures, were 1.0 mGy, 4.0 mGy and 1.6 mGy, respectively, while for urinary bladder and testes of the RUG were 3.4 mGy and 5.9 mGy, respectively. The median values of effective doses for the HSG and RUG procedures were 0.65 mSv and 0.59 mSv, respectively. The median values of effective dose per hospital for the HSG and RUG procedures had a range of 1.6-2.8 mSv and 1.9-5.6 mSv, respectively, while the overall differences between individual effective doses across the four hospitals varied by factors of up to 22.0 and 46.7, respectively for the HSG and RUG procedures. The proposed diagnostic reference levels (DRLs) for the HSG and RUG were for KAP 2.8 Gy cm2 and 3.9 Gy cm2, for fluoroscopy time 0.8 min and 0.9 min, and for number of images 5 and 4, respectively. The suggested DRLs for the HSG and RUG procedures may be used by the radiology departments in Tanzania for management of attained dose levels until the national DRLs are established.
Cost-effectiveness of PET and PET/computed tomography: a systematic review.
Gerke, Oke; Hermansson, Ronnie; Hess, Søren; Schifter, Søren; Vach, Werner; Høilund-Carlsen, Poul Flemming
2015-01-01
The development of clinical diagnostic procedures comprises early-phase and late-phase studies to elucidate diagnostic accuracy and patient outcome. Economic assessments of new diagnostic procedures compared with established work-ups indicate additional cost for 1 additional unit of effectiveness measure by means of incremental cost-effectiveness ratios when considering the replacement of the standard regimen by a new diagnostic procedure. This article discusses economic assessments of PET and PET/computed tomography reported until mid-July 2014. Forty-seven studies on cancer and noncancer indications were identified but, because of the widely varying scope of the analyses, a substantial amount of work remains to be done. Copyright © 2015 Elsevier Inc. All rights reserved.
Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming
2015-01-01
Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.
Emerging applications of nanoparticles for lung cancer diagnosis and therapy
NASA Astrophysics Data System (ADS)
Sukumar, Uday Kumar; Bhushan, Bharat; Dubey, Poornima; Matai, Ishita; Sachdev, Abhay; Packirisamy, Gopinath
2013-07-01
Lung cancer is by far the leading cause of cancer-related mortality worldwide, most of them being active tobacco smokers. Non small cell lung cancer accounts for around 85% to 90% of deaths, whereas the rest is contributed by small cell lung cancer. The extreme lethality of lung cancer arises due to lack of suitable diagnostic procedures for early detection of lung cancer and ineffective conventional therapeutic strategies. In course with desperate attempts to address these issues independently, a multifunctional nanotherapeutic or diagnostic system is being sought as a favorable solution. The manifestation of physiochemical properties of such nanoscale systems is tuned favorably to come up with a versatile cancer cell targeted diagnostic and therapeutic system. Apart from this, the aspect of being at nanoscale by itself confers the system with an advantage of passive accumulation at the site of tumor. This review provides a broad perspective of three major subclasses of such nanoscale therapeutic and diagnostic systems which include polymeric nanoparticles-based approaches, metal nanoparticles-based approaches, and bio-nanoparticles-based approaches. This review work also serves the purpose of gaining an insight into the pros and cons of each of these approaches with a prospective improvement in lung cancer therapeutics and diagnostics.
Tranexamic Acid Use in US Children’s Hospitals
Nishijima, Daniel K.; Monuteaux, Michael C.; Faraoni, David; Goobie, Susan M.; Lee, Lois; Galante, Joseph; Holmes, James F.; Kuppermann, Nathan
2016-01-01
Background The prevalence of tranexamic acid (TXA) use for trauma and other conditions in children is unknown. Objective The objective of this study was to describe the use of TXA in US children’s hospitals for children in general, and specifically for trauma. Methods We conducted a secondary analysis of a large, administrative database of 36 US children’s hospitals. We included children younger than 18 years who received TXA (based on pharmacy charge codes) from 2009 to 2013. Patients were grouped into the following diagnostic categories: trauma, congenital heart surgery, scoliosis surgery, craniosynostosis/craniofacial surgery, and other, based on ICD-9 principle procedure and diagnostic codes. TXA administration and dosage, in-hospital clinical variables, and diagnostic and procedure codes were documented. Results A total of 35,478 pediatric encounters with a TXA charge were included in the study cohort. The proportions of children who received TXA were similar across the years 2009–2013. Only 110 encounters (0.31%) were for traumatic conditions. Congenital heart surgery accounted for more than one-half of the encounters (22,863, 64%).. Overall the median estimated weight-based dose of TXA was 22.4 mg/kg (IQR 7.3 to 84.9 mg/kg). Conclusions We identified a wide frequency of use and range of doses of TXA for several diagnostic conditions in children. The use of TXA among injured children, however, appears to be rare despite its common use and efficacy among injured adults. Further work is needed to recommend appropriate indications for TXA, and provide dosage guidelines among children with a variety of conditions, including trauma. PMID:27017532
Knowledge-based diagnosis for aerospace systems
NASA Technical Reports Server (NTRS)
Atkinson, David J.
1988-01-01
The need for automated diagnosis in aerospace systems and the approach of using knowledge-based systems are examined. Research issues in knowledge-based diagnosis which are important for aerospace applications are treated along with a review of recent relevant research developments in Artificial Intelligence. The design and operation of some existing knowledge-based diagnosis systems are described. The systems described and compared include the LES expert system for liquid oxygen loading at NASA Kennedy Space Center, the FAITH diagnosis system developed at the Jet Propulsion Laboratory, the PES procedural expert system developed at SRI International, the CSRL approach developed at Ohio State University, the StarPlan system developed by Ford Aerospace, the IDM integrated diagnostic model, and the DRAPhys diagnostic system developed at NASA Langley Research Center.
Brown, Kate L; Crowe, Sonya; Pagel, Christina; Bull, Catherine; Muthialu, Nagarajan; Gibbs, John; Cunningham, David; Utley, Martin; Tsang, Victor T; Franklin, Rodney
2013-08-01
To categorise records according to primary cardiac diagnosis in the United Kingdom Central Cardiac Audit Database in order to add this information to a risk adjustment model for paediatric cardiac surgery. Codes from the International Paediatric Congenital Cardiac Code were mapped to recognisable primary cardiac diagnosis groupings, allocated using a hierarchy and less refined diagnosis groups, based on the number of functional ventricles and presence of aortic obstruction. A National Clinical Audit Database. Patients Children undergoing cardiac interventions: the proportions for each diagnosis scheme are presented for 13,551 first patient surgical episodes since 2004. In Scheme 1, the most prevalent diagnoses nationally were ventricular septal defect (13%), patent ductus arteriosus (10.4%), and tetralogy of Fallot (9.5%). In Scheme 2, the prevalence of a biventricular heart without aortic obstruction was 64.2% and with aortic obstruction was 14.1%; the prevalence of a functionally univentricular heart without aortic obstruction was 4.3% and with aortic obstruction was 4.7%; the prevalence of unknown (ambiguous) number of ventricles was 8.4%; and the prevalence of acquired heart disease only was 2.2%. Diagnostic groups added to procedural information: of the 17% of all operations classed as "not a specific procedure", 97.1% had a diagnosis identified in Scheme 1 and 97.2% in Scheme 2. Diagnostic information adds to surgical procedural data when the complexity of case mix is analysed in a national database. These diagnostic categorisation schemes may be used for future investigation of the frequency of conditions and evaluation of long-term outcome over a series of procedures.
NASA Astrophysics Data System (ADS)
Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.
2003-07-01
The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.
ERIC Educational Resources Information Center
Stevenson, Kimberly
This master's thesis describes the development of an expert system and interactive videodisc computer-based instructional job aid used for assisting in the integration of electron beam lithography devices. Comparable to all comprehensive training, expert system and job aid development require a criterion-referenced systems approach treatment to…
The Buffer Diagnostic Prototype: A fault isolation application using CLIPS
NASA Technical Reports Server (NTRS)
Porter, Ken
1994-01-01
This paper describes problem domain characteristics and development experiences from using CLIPS 6.0 in a proof-of-concept troubleshooting application called the Buffer Diagnostic Prototype. The problem domain is a large digital communications subsystems called the real-time network (RTN), which was designed to upgrade the launch processing system used for shuttle support at KSC. The RTN enables up to 255 computers to share 50,000 data points with millisecond response times. The RTN's extensive built-in test capability but lack of any automatic fault isolation capability presents a unique opportunity for a diagnostic expert system application. The Buffer Diagnostic Prototype addresses RTN diagnosis with a multiple strategy approach. A novel technique called 'faulty causality' employs inexact qualitative models to process test results. Experimental knowledge provides a capability to recognize symptom-fault associations. The implementation utilizes rule-based and procedural programming techniques, including a goal-directed control structure and simple text-based generic user interface that may be reusable for other rapid prototyping applications. Although limited in scope, this project demonstrates a diagnostic approach that may be adapted to troubleshoot a broad range of equipment.
Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao
2014-01-01
Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179
Mickes, Laura; Flowe, Heather D; Wixted, John T
2012-12-01
A police lineup presents a real-world signal-detection problem because there are two possible states of the world (the suspect is either innocent or guilty), some degree of information about the true state of the world is available (the eyewitness has some degree of memory for the perpetrator), and a decision is made (identifying the suspect or not). A similar state of affairs applies to diagnostic tests in medicine because, in a patient, the disease is either present or absent, a diagnostic test yields some degree of information about the true state of affairs, and a decision is made about the presence or absence of the disease. In medicine, receiver operating characteristic (ROC) analysis is the standard method for assessing diagnostic accuracy. By contrast, in the eyewitness memory literature, this powerful technique has never been used. Instead, researchers have attempted to assess the diagnostic performance of different lineup procedures using methods that cannot identify the better procedure (e.g., by computing a diagnosticity ratio). Here, we describe the basics of ROC analysis, explaining why it is needed and showing how to use it to measure the performance of different lineup procedures. To illustrate the unique advantages of this technique, we also report 3 ROC experiments that were designed to investigate the diagnostic accuracy of simultaneous versus sequential lineups. According to our findings, the sequential procedure appears to be inferior to the simultaneous procedure in discriminating between the presence versus absence of a guilty suspect in a lineup.
Yudkowsky, Rachel; Otaki, Junji; Lowenstein, Tali; Riddle, Janet; Nishigori, Hiroshi; Bordage, Georges
2009-08-01
Diagnostic accuracy is maximised by having clinical signs and diagnostic hypotheses in mind during the physical examination (PE). This diagnostic reasoning approach contrasts with the rote, hypothesis-free screening PE learned by many medical students. A hypothesis-driven PE (HDPE) learning and assessment procedure was developed to provide targeted practice and assessment in anticipating, eliciting and interpreting critical aspects of the PE in the context of diagnostic challenges. This study was designed to obtain initial content validity evidence, performance and reliability estimates, and impact data for the HDPE procedure. Nineteen clinical scenarios were developed, covering 160 PE manoeuvres. A total of 66 Year 3 medical students prepared for and encountered three clinical scenarios during required formative assessments. For each case, students listed anticipated positive PE findings for two plausible diagnoses before examining the patient; examined a standardised patient (SP) simulating one of the diagnoses; received immediate feedback from the SP, and documented their findings and working diagnosis. The same students later encountered some of the scenarios during their Year 4 clinical skills examination. On average, Year 3 students anticipated 65% of the positive findings, correctly performed 88% of the PE manoeuvres and documented 61% of the findings. Year 4 students anticipated and elicited fewer findings overall, but achieved proportionally more discriminating findings, thereby more efficiently achieving a diagnostic accuracy equivalent to that of students in Year 3. Year 4 students performed better on cases on which they had received feedback as Year 3 students. Twelve cases would provide a reliability of 0.80, based on discriminating checklist items only. The HDPE provided medical students with a thoughtful, deliberate approach to learning and assessing PE skills in a valid and reliable manner.
Current diagnostic procedures for diagnosing vertigo and dizziness
Walther, Leif Erik
2017-01-01
Vertigo is a multisensory syndrome that otolaryngologists are confronted with every day. With regard to the complex functions of the sense of orientation, vertigo is considered today as a disorder of the sense of direction, a disturbed spatial perception of the body. Beside the frequent classical syndromes for which vertigo is the leading symptom (e.g. positional vertigo, vestibular neuritis, Menière’s disease), vertigo may occur as main or accompanying symptom of a multitude of ENT-related diseases involving the inner ear. It also concerns for example acute and chronic viral or bacterial infections of the ear with serous or bacterial labyrinthitis, disorders due to injury (e.g. barotrauma, fracture of the oto-base, contusion of the labyrinth), chronic-inflammatory bone processes as well as inner ear affections in the perioperative course. In the last years, diagnostics of vertigo have experienced a paradigm shift due to new diagnostic possibilities. In the diagnostics of emergency cases, peripheral and central disorders of vertigo (acute vestibular syndrome) may be differentiated with simple algorithms. The introduction of modern vestibular test procedures (video head impulse test, vestibular evoked myogenic potentials) in the clinical practice led to new diagnostic options that for the first time allow a complex objective assessment of all components of the vestibular organ with relatively low effort. Combined with established methods, a frequency-specific assessment of the function of vestibular reflexes is possible. New classifications allow a clinically better differentiation of vertigo syndromes. Modern radiological procedures such as for example intratympanic gadolinium application for Menière’s disease with visualization of an endolymphatic hydrops also influence current medical standards. Recent methodical developments significantly contributed to the possibilities that nowadays vertigo can be better and more quickly clarified in particular in otolaryngology. PMID:29279722
A diagnostic for determining the quality of single-reference electron correlation methods
NASA Technical Reports Server (NTRS)
Lee, Timothy J.; Taylor, Peter R.
1989-01-01
It was recently proposed that the Euclidian norm of the t(sub 1) vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appopriate. This diagnostic, T(sub 1) is defined for use with self-consistent-field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T(sub 1) is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of non-dynamical electron correlation and is far superior to C(sub 0) from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T(sub 1) (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.
A diagnostic for determining the quality of single-reference electron correlation methods
NASA Technical Reports Server (NTRS)
Lee, Timothy J.; Taylor, Peter R.
1989-01-01
It was recently proposed that the Euclidian norm of the t sub 1 vector of the coupled cluster wave function (normalized by the number of electrons included in the correlation procedure) could be used to determine whether a single-reference-based electron correlation procedure is appropriate. This diagnostic, T sub 1, is defined for use with self consistent field molecular orbitals and is invariant to the same orbital rotations as the coupled cluster energy. T sub 1 is investigated for several different chemical systems which exhibit a range of multireference behavior, and is shown to be an excellent measure of the importance of nondynamical electron correlation and is far superior to C sub 0 from a singles and doubles configuration interaction wave function. It is further suggested that when the aim is to recover a large fraction of the dynamical electron correlation energy, a large T sub 1 (i.e., greater than 0.02) probably indicates the need for a multireference electron correlation procedure.
Optimal Combinations of Diagnostic Tests Based on AUC.
Huang, Xin; Qin, Gengsheng; Fang, Yixin
2011-06-01
When several diagnostic tests are available, one can combine them to achieve better diagnostic accuracy. This article considers the optimal linear combination that maximizes the area under the receiver operating characteristic curve (AUC); the estimates of the combination's coefficients can be obtained via a nonparametric procedure. However, for estimating the AUC associated with the estimated coefficients, the apparent estimation by re-substitution is too optimistic. To adjust for the upward bias, several methods are proposed. Among them the cross-validation approach is especially advocated, and an approximated cross-validation is developed to reduce the computational cost. Furthermore, these proposed methods can be applied for variable selection to select important diagnostic tests. The proposed methods are examined through simulation studies and applications to three real examples. © 2010, The International Biometric Society.
ERIC Educational Resources Information Center
Albanese, Mark A.; Jacobs, Richard M.
1990-01-01
The reliability and validity of a procedure to measure diagnostic-reasoning and problem-solving skills taught in predoctoral orthodontic education were studied using 68 second year dental students. The procedure includes stimulus material and 33 multiple-choice items. It is a feasible way of assessing problem-solving skills in dentistry education…
RECONSTRUCTION OF INDIVIDUAL DOSES DUE TO MEDICAL EXPOSURES FOR MEMBERS OF THE TECHA RIVER COHORT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shagina, N. B.; Golikov, V.; Degteva, M. O.
Purpose: To describe a methodology for reconstruction of doses due to medical exposures for members of the Techa River Cohort (TRC) who received diagnostic radiation at the clinic of the Urals Research Center for Radiation Medicine (URCRM) in 1952–2005. To calculate doses of medical exposure for the TRC members and compare with the doses that resulted from radioactive contamination of the Techa River. Material and Methods: Reconstruction of individual medical doses is based on data on x-ray diagnostic procedures available for each person examined at the URCRM clinics and values of absorbed dose in 12 organs per typical x-ray proceduremore » calculated with the use of a mathematical phantom. Personal data on x-ray diagnostic examinations have been complied in the computerized “Registry of x-ray diagnostic procedures.” Sources of information are archival registry books from the URCRM x-ray room (available since 1956) and records on x-ray diagnostic procedures in patient-case histories (since 1952). The absorbed doses for 12 organs of interest have been evaluated per unit typical x-ray procedure with account taken of the x-ray examination parameters characteristic for the diagnostic machines used at the URCRM clinics. These parameters have been evaluated from published data on technical characteristics of the x-ray diagnostic machines used at the URCRM clinics in 1952–1988 and taken from the x-ray room for machines used at the URCRM in 1989–2005. Absorbed doses in the 12 organs per unit typical x-ray procedure have been calculated with use of a special computer code, EDEREX, developed at the Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev. Individual accumulated doses of medical exposure have been calculated with a computer code, MEDS (Medical Exposure Dosimetry System), specifically developed at the URCRM. Results: At present, the “Registry of x-ray diagnostic procedures” contains information on individual x-ray examinations for over 9,500 persons including 6,415 TRC members. Statistical analysis of the Registry data showed that the more frequent types of examinations were fluoroscopy and radiography of the chest and fluoroscopy of the stomach and the esophagus. Average absorbed doses accumulated by year 2005 calculated for the 12 organs varied from 4 mGy for testes to 40 mGy for bone surfaces. Maximum individual medical doses could reach 500–650 mGy and in some cases exceeded doses from exposure at the Techa River. Conclusions: For the first time the doses of medical exposure were calculated and analyzed for members of the Techa River Cohort who received diagnostic radiation at the URCRM clinics. These results are being used in radiation-risk analysis to adjust for this source of confounding exposure in the TRC.« less
Ho, Sirikit; Lukacs, Zoltan; Hoffmann, Georg F; Lindner, Martin; Wetter, Thomas
2007-07-01
In newborn screening with tandem mass spectrometry, multiple intermediary metabolites are quantified in a single analytical run for the diagnosis of fatty-acid oxidation disorders, organic acidurias, and aminoacidurias. Published diagnostic criteria for these disorders normally incorporate a primary metabolic marker combined with secondary markers, often analyte ratios, for which the markers have been chosen to reflect metabolic pathway deviations. We applied a procedure to extract new markers and diagnostic criteria for newborn screening to the data of newborns with confirmed medium-chain acyl-CoA dehydrogenase deficiency (MCADD) and a control group from the newborn screening program, Heidelberg, Germany. We validated the results with external data of the screening center in Hamburg, Germany. We extracted new markers by performing a systematic search for analyte combinations (features) with high discriminatory performance for MCADD. To select feature thresholds, we applied automated procedures to separate controls and cases on the basis of the feature values. Finally, we built classifiers from these new markers to serve as diagnostic criteria in screening for MCADD. On the basis of chi(2) scores, we identified approximately 800 of >628,000 new analyte combinations with superior discriminatory performance compared with the best published combinations. Classifiers built with the new features achieved diagnostic sensitivities and specificities approaching 100%. Feature construction methods provide ways to disclose information hidden in the set of measured analytes. Other diagnostic tasks based on high-dimensional metabolic data might also profit from this approach.
Nipple piercing may be contraindicated in male patients with chest implants.
de Kleer, N; Cohen, M; Semple, J; Simor, A; Antonyshyn, O
2001-08-01
The authors present a man who underwent chest augmentation and nipple piercing. The patient developed chronic nipple infection, which led to unnecessary invasive diagnostic procedures, serious implant infection, and eventually urgent explantation. This unfavorable scenario illustrates the distinct features of the procedure in men, which includes close proximity of the nipple to the implant and reduced awareness by health care providers. Based on this case the authors recommend avoiding nipple piercing in men with chest implants.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
Brenner, Thorsten; Decker, Sebastian O; Grumaz, Silke; Stevens, Philip; Bruckner, Thomas; Schmoch, Thomas; Pletz, Mathias W; Bracht, Hendrik; Hofer, Stefan; Marx, Gernot; Weigand, Markus A; Sohn, Kai
2018-02-01
Sepsis remains a major challenge, even in modern intensive care medicine. The identification of the causative pathogen is crucial for an early optimization of the antimicrobial treatment regime. In this context, culture-based diagnostic procedures (e.g., blood cultures) represent the standard of care, although they are associated with relevant limitations. Accordingly, culture-independent molecular diagnostic procedures might be of help for the identification of the causative pathogen in infected patients. The concept of an unbiased sequence analysis of circulating cell-free DNA (cfDNA) from plasma samples of septic patients by next-generation sequencing (NGS) has recently been identified to be a promising diagnostic platform for critically ill patients suffering from bloodstream infections. Although this new approach might be more sensitive and specific than culture-based state-of-the-art technologies, additional clinical trials are needed to exactly define the performance as well as clinical value of a NGS-based approach. Next GeneSiS is a prospective, observational, noninterventional, multicenter study to assess the diagnostic performance of a NGS-based approach for the detection of relevant infecting organisms in patients with suspected or proven sepsis [according to recent sepsis definitions (sepsis-3)] by the use of the quantitative sepsis indicating quantifier (SIQ) score in comparison to standard (culture-based) microbiological diagnostics. The clinical value of this NGS-based approach will be estimated by a panel of independent clinical specialists, retrospectively identifying potential changes in patients' management based on NGS results. Further subgroup analyses will focus on the clinical value especially for patients suffering from a failure of empiric treatment within the first 3 days after onset [as assessed by death of the patient or lack of improvement of the patient's clinical condition (in terms of an inadequate decrease of SOFA-score) or persistent high procalcitonin levels]. This prospective, observational, noninterventional, multicenter study for the first time investigates the performance as well as the clinical value of a NGS-based approach for the detection of bacteremia in patients with sepsis and may therefore be a pivotal step toward the clinical use of NGS in this indication. DRKS-ID: DRKS00011911 (registered October 9, 2017) https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00011911; ClinicalTrials.gov Identifier: NCT03356249 (registered November 29, 2017) https://clinicaltrials.gov/ct2/show/NCT03356249.
Skinner, Sarah
2013-06-01
Diagnostic radiology procedures, such as computed tomography (CT) and X-ray, are an increasing source of ionising radiation exposure to our community. Exposure to ionising radiation is associated with increased risk of malignancy, proportional to the level of exposure. Every diagnostic test using ionising radiation needs to be justified by clinical need. General practitioners need a working knowledge of radiation safety so they can adequately inform their patients of the risks and benefits of diagnostic imaging procedures.
Ahlers, M O; Jakstat, H A
2005-07-01
The prerequisite for structured individual therapy of craniomandibular dysfunctions is differential diagnostics. Suggestions for the structured recording of findings and their structured evaluation beyond the global diagnosis of "craniomandibular disorders" have been published. Only this structured approach enables computerization of the diagnostic process. The respective software is available for use in practice (CMDcheck for CMD screening, CMDfact for the differential diagnostics). Based on this structured diagnostics, knowledge-based therapy planning is also conceivable. The prerequisite for this would be a model of achieving consensus on the indicated forms of therapy related to the diagnosis. Therefore, a procedure for evidence-based achievement of consensus on suitable forms of therapy in CMD was developed first in multicentric cooperation, and then implemented in corresponding software. The clinical knowledge of experienced specialists was included consciously for the consensus achievement process. At the same time, anonymized mathematical statistical evaluations were used for control and objectification. Different examiners form different departments of several universities working independently of one another assigned the theoretically conceiveable therapeutic alternatives to the already published diagnostic scheme. After anonymization, the correlation of these assignments was then calculated mathematically. For achieving consensus in those cases for which no agreement initally existed, agreement was subsequently arrived at in the course of a consensus conference on the basis of literature evaluations and the discussion of clinical case examples. This consensus in turn finally served as the basis of a therapy planner implemented in the above-mentioned diagnostic software CMDfact. Contributing to quality assurance, the principles of programming this assistant as well as the interface for linking into the diagnostic software are documented and also published here.
A signal-detection-based diagnostic-feature-detection model of eyewitness identification.
Wixted, John T; Mickes, Laura
2014-04-01
The theoretical understanding of eyewitness identifications made from a police lineup has long been guided by the distinction between absolute and relative decision strategies. In addition, the accuracy of identifications associated with different eyewitness memory procedures has long been evaluated using measures like the diagnosticity ratio (the correct identification rate divided by the false identification rate). Framed in terms of signal-detection theory, both the absolute/relative distinction and the diagnosticity ratio are mainly relevant to response bias while remaining silent about the key issue of diagnostic accuracy, or discriminability (i.e., the ability to tell the difference between innocent and guilty suspects in a lineup). Here, we propose a signal-detection-based model of eyewitness identification, one that encourages the use of (and helps to conceptualize) receiver operating characteristic (ROC) analysis to measure discriminability. Recent ROC analyses indicate that the simultaneous presentation of faces in a lineup yields higher discriminability than the presentation of faces in isolation, and we propose a diagnostic feature-detection hypothesis to account for that result. According to this hypothesis, the simultaneous presentation of faces allows the eyewitness to appreciate that certain facial features (viz., those that are shared by everyone in the lineup) are non-diagnostic of guilt. To the extent that those non-diagnostic features are discounted in favor of potentially more diagnostic features, the ability to discriminate innocent from guilty suspects will be enhanced.
[Definition of the Diagnosis Osteomyelitis-Osteomyelitis Diagnosis Score (ODS)].
Schmidt, H G K; Tiemann, A H; Braunschweig, R; Diefenbeck, M; Bühler, M; Abitzsch, D; Haustedt, N; Walter, G; Schoop, R; Heppert, V; Hofmann, G O; Glombitza, M; Grimme, C; Gerlach, U-J; Flesch, I
2011-08-01
The disease "osteomyelitis" is characterised by different symptoms and parameters. Decisive roles in the development of the disease are played by the causative bacteria, the route of infection and the individual defense mechanisms of the host. The diagnosis is based on different symptoms and findings from the clinical history, clinical symptoms, laboratory results, diagnostic imaging, microbiological and histopathological analyses. While different osteomyelitis classifications have been published, there is to the best of our knowledge no score that gives information how sure the diagnosis "osteomyelitis" is in general. For any scientific study of a disease a valid definition is essential. We have developed a special osteomyelitis diagnosis score for the reliable classification of clinical, laboratory and technical findings. The score is based on five diagnostic procedures: 1) clinical history and risk factors, 2) clinical examination and laboratory results, 3) diagnostic imaging (ultrasound, radiology, CT, MRI, nuclear medicine and hybrid methods), 4) microbiology, and 5) histopathology. Each diagnostic procedure is related to many individual findings, which are weighted by a score system, in order to achieve a relevant value for each assessment. If the sum of the five diagnostic criteria is 18 or more points, the diagnosis of osteomyelitis can be viewed as "safe" (diagnosis class A). Between 8-17 points the diagnosis is "probable" (diagnosis class B). Less than 8 points means that the diagnosis is "possible, but unlikely" (class C diagnosis). Since each parameter can score six points at a maximum, a reliable diagnosis can only be achieved if at least 3 parameters are scored with 6 points. The osteomyelitis diagnosis score should help to avoid the false description of a clinical presentation as "osteomyelitis". A safe diagnosis is essential for the aetiology, treatment and outcome studies of osteomyelitis. © Georg Thieme Verlag KG Stuttgart · New York.
Chung, Sang Mi; Choi, Ju Whan; Lee, Young Seok; Choi, Jong Hyun; Oh, Jee Youn; Min, Kyung Hoon; Hur, Gyu Young; Lee, Sung Yong; Shim, Jae Jeong; Kang, Kyung Ho
2018-06-19
Bronchoscopy is a useful diagnostic and therapeutic tool. However, the clinical use of high-flow nasal cannula (HFNC) in adults with acute respiratory failure for diagnostic and invasive procedures has not been well evaluated. We present our experiences of well-tolerated diagnostic bronchoscopy as well as cases of improved saturation in hypoxaemic patients after a therapeutic bronchoscopic procedure. We retrospectively reviewed data of hypoxaemic patients who had undergone bronchoscopy for diagnostic or therapeutic purposes from October 2015 to February 2017. Ten patients (44-75 years of age) were enrolled. The clinical purposes of bronchoscopy were for diagnosis in seven patients and for intervention in three patients. For the diagnoses, we performed bronchoalveolar lavage in six patients. One patient underwent endobronchial ultrasonography with transbronchial needle aspiration of a lymph node to investigate tumour involvement. Patients who underwent bronchoscopy for therapeutic interventions had endobronchial mass or blood clot removal with cryotherapy for bleeding control. The mean saturation (SpO₂) of pre-bronchoscopy in room air was 84.1%. The lowest and highest mean saturation with HFNC during the procedure was 95% and 99.4, respectively. The mean saturation in room air post-bronchoscopy was 87.4%, which was 3.3% higher than the mean room air SpO₂ pre-bronchoscopy. Seven patients with diagnostic bronchoscopy had no hypoxic event. Three patients with interventional bronchoscopy showed improvement in saturation after the procedure. Bronchoscopy was well tolerated in all 10 cases. This study suggests that the use of HFNC in hypoxaemic patients during diagnostic and therapeutic bronchoscopy procedures has clinical effectiveness. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.
Leppington, Charmody; Gleberzon, Brian; Fortunato, Lisa; Doucet, Nicolea; Vandervalk, Kyle
2012-01-01
The purpose of this study was to determine if diagnostic and therapeutic procedures for the cervical and cranial spine taught to students during the undergraduate program at Canadian Memorial Chiropractic College are required to be used during their internship by their supervising clinicians and, if so, to what extent these procedures are used. Course manuals and course syllabi from the Applied Chiropractic and Clinical Diagnosis faculty of the undergraduate chiropractic program for the academic year 2009-2010 were consulted and a list of all diagnostic and therapeutic procedures for the cranial and cervical spine was compiled. This survey asked clinicians to indicate if they themselves used or if they required the students they were supervising to use each procedure listed and, if so, to what extent each procedure was used. Demographic information of each clinician was also obtained. In general, most diagnostic procedures of the head and neck were seldom used, with the exception of postural observation and palpation. By contrast, most cervical orthopaedic tests were often used, with the exception of tests for vertigo. Most therapeutic procedures were used frequently with the exception of prone cervical and "muscle" adjustments. There was a low degree of vertical integration for cranial procedures as compared to a much higher degree of vertical integration for cervical procedures between the undergraduate and clinical internship programs taught. Vertical integration is an important element of curricular planning and these results may be helpful to aid educators to more appropriately allocate classroom instruction.
Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Using 19-G Needle for Sarcoidosis.
Balwan, Akshu
2018-05-16
Flexible bronchoscopy with endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is increasingly being used to obtain pathology specimens for diagnosis of sarcoidosis. There is wide variation in reported diagnostic yield in literature. New TBNA needles are available in the market but data are lacking about their diagnostic yield especially for sarcoidosis. This study reports the diagnostic yield of bronchoscopy with EBUS-TBNA using ViziShot FLEX 19-G needle in a series of patients with suspected sarcoidosis. This is a retrospective chart review for diagnostic yield of the 19-G EBUS-TBNA needle for suspected sarcoidosis. Eighty-six EBUS bronchoscopies were performed, 15 were done with clinical suspicion of sarcoidosis. The 19-G needle was used for all cases of suspected sarcoidosis. The procedure was diagnostic of sarcoidosis in 14 (93.3%) patients by TBNA with 1 nondiagnostic bronchoscopy. Procedural diagnostic yield was 93.3%. Eighty-five percent (28/33) of sampled lymph nodes were positive for noncaseating granulomas. The yield of transbronchial lung biopsy (TBLB) and endobronchial lung biopsy was 38% (5/13) and 43% (6/14), respectively. TBLB and endobronchial lung biopsy did not add to the diagnostic yield of the procedure. No significant adverse events were noted. This series reports a higher diagnostic yield than most other published studies and opens platform for direct comparison of each available needle. It also adds to the safety data for this larger needle. In addition, it raises doubt into utility of TBLB for diagnosis of sarcoidosis, which can increase the procedural complications.
Blueprint for the Diagnosis of Difficulties with Cardinality.
ERIC Educational Resources Information Center
Dunlap, William P.; Brennen, Alison H.
1981-01-01
The article describes a diagnostic procedure for assessing children's mental images and knowledge of cardinal numbers, 0 through 9. The diagnostic procedure includes the assessment of a child's visual memory, visual perception, symbol recognition, oral naming of numerals, and symbol-set linkage. (Author/SBH)
Diagnosis of liver disease in domestic ferrets (Mustela putorius).
Huynh, Minh; Laloi, Flora
2013-01-01
Liver disease in ferrets is often subclinical and underdiagnosed. Clinical pathology and diagnostic imaging are needed to guide clinicians but definite diagnosis is based on histopathologic lesions. Inflammatory digestive conditions can lead to ascending tract infection and hepatobiliary inflammation. Ferrets have a specific sensitivity to hepatic lipidosis. Incidence of hepatic neoplasia is high in ferrets. After a summary of anatomy and physiology of the ferret liver, hepatic diseases known in ferret species are reviewed with their subsequent diagnostic procedures. Copyright © 2013 Elsevier Inc. All rights reserved.
Jones, Lyell K; Ney, John P
2016-12-01
Accurate coding is critically important for clinical practice and research. Ongoing changes to diagnostic and billing codes require the clinician to stay abreast of coding updates. Payment for health care services, data sets for health services research, and reporting for medical quality improvement all require accurate administrative coding. This article provides an overview of administrative coding for patients with muscle disease and includes a case-based review of diagnostic and Evaluation and Management (E/M) coding principles in patients with myopathy. Procedural coding for electrodiagnostic studies and neuromuscular ultrasound is also reviewed.
Lee, Minju; Min, Byung-Hoon; Lee, Hyuk; Ahn, Sangjeong; Lee, Jun Haeng; Rhee, Poong-Lyul; Kim, Jae J.; Sohn, Tae Sung; Kim, Sung; Kim, Kyoung-Mee
2015-01-01
Abstract As treatment decisions for patients with gastric subepithelial tumors (SETs) largely depend on the histopathologic diagnosis, noninvasive and effective tissue acquisition methods are definitely required for proper management of gastric SETs. Recently, a new endoscopic ultrasonography-guided fine needle biopsy (EUS-FNB) device with ProCore reverse bevel technology was developed. We aimed to elucidate the feasibility and diagnostic yield of EUS-FNB with this new core biopsy needle device in patients with gastric SETs. A prospectively maintained database was retrospectively reviewed to identify consecutive patients who underwent EUS-FNB with a 22-gauge ProCore needle for gastric SETs 2 cm or larger. The main outcome measurement was the diagnostic yield of EUS-FNB. Procedure results were categorized into diagnostic, suggestive, or nondiagnostic. Of the 43 patients, needle punctures were successful in all cases irrespective of tumor location. EUS-FNB procedure results were diagnostic in 86.0%, suggestive in 4.7%, and nondiagnostic in 9.3% of cases, respectively. The diagnostic yield was the highest in fundus (100.0%), followed by body (89.5%), cardia (83.3%), and antrum (50.0%). All 18 patients with cardiac SET were finally diagnosed to have leiomyoma, and 16 patients with diagnostic or suggestive results avoided surgery. A heterogeneous echo pattern on EUS was found in 33.3% of cases with nondiagnostic or suggestive results and in 5.4% with diagnostic results. In multivariate analysis, no independent predictor of unsuccessful EUS-FNB with nondiagnostic or suggestive results was identified. Agreement between EUS-FNB and surgical pathology was 100% with respect to the diagnosis of gastrointestinal stromal tumor. However, there was a significant discrepancy in mitotic counts observed between the EUS-FNB and surgical specimens in patients with gastrointestinal stromal tumor. There were no significant procedure-related adverse events during and after the procedures. EUS-FNB with a 22G ProCore needle is a technically feasible, safe, and effective procedure for pathologic diagnosis of gastric SETs. This procedure can help refine surgical indications and facilitate a proper treatment decisions for gastric SETs, especially in the cardia. PMID:26448008
Pesavento, Raffaele; de Conti, Giorgio; Minotto, Isabella; Prandoni, Paolo
2008-12-01
Pulmonary embolism (PE) is a common condition carrying a significant degree of mortality if not diagnosed early. The diagnosis of PE is challenging, because of the non-specific nature of its clinical features. For many years the diagnostic strategies for PE have mainly involved ventilation/perfusion lung scan as the chief diagnostic procedure, often associated with a few clinical models of pre-test probability and the D-dimer test. These modalities of diagnosing PE, though quite satisfactory in various clinical settings, show several limitations, the most important one being the high rate of non-diagnostic procedures. The introduction of computed tomography (CT) has changed the diagnostic strategies and has become the main diagnostic procedure for diagnosing PE. CT is undergoing a rapid technological upgrade, which will open in the near future new frontiers in the diagnosis of PE. Nonetheless, CT carries a number of limitations, which should be carefully identified. This article reviews the evidences on both the traditional and newer diagnostic strategies for PE, outlines their strengths and weaknesses and describes future applications of CT for diagnosing PE.
21 CFR 886.1380 - Diagnostic condensing lens.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...
Systematic Sensor Selection Strategy (S4) User Guide
NASA Technical Reports Server (NTRS)
Sowers, T. Shane
2012-01-01
This paper describes a User Guide for the Systematic Sensor Selection Strategy (S4). S4 was developed to optimally select a sensor suite from a larger pool of candidate sensors based on their performance in a diagnostic system. For aerospace systems, selecting the proper sensors is important for ensuring adequate measurement coverage to satisfy operational, maintenance, performance, and system diagnostic criteria. S4 optimizes the selection of sensors based on the system fault diagnostic approach while taking conflicting objectives such as cost, weight and reliability into consideration. S4 can be described as a general architecture structured to accommodate application-specific components and requirements. It performs combinational optimization with a user defined merit or cost function to identify optimum or near-optimum sensor suite solutions. The S4 User Guide describes the sensor selection procedure and presents an example problem using an open source turbofan engine simulation to demonstrate its application.
Code of Federal Regulations, 2011 CFR
2011-10-01
... based on the correct diagnostic and procedural information. Elective, when applied to admission or to a... the interest equals at least five percent of the value of the property or assets of the entity. Health... practitioners other than physicians means those health professionals who do not hold a doctor of medicine or...
Code of Federal Regulations, 2012 CFR
2012-10-01
... based on the correct diagnostic and procedural information. Elective, when applied to admission or to a... the interest equals at least five percent of the value of the property or assets of the entity. Health... practitioners other than physicians means those health professionals who do not hold a doctor of medicine or...
20 CFR 416.919m - Diagnostic tests or procedures.
Code of Federal Regulations, 2010 CFR
2010-04-01
... AGED, BLIND, AND DISABLED Determining Disability and Blindness Standards for the Type of Referral and for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any..., arteriograms, or cardiac catheterizations for the evaluation of disability under the Supplemental Security...
Upper Urinary Tract Tumors: Which Diagnostic Methods Are Needed?
Maruschke, Matthias; Kram, Wolfgang; Zimpfer, Annette; Kundt, Günther; Hakenberg, Oliver W
2017-01-01
We reviewed the data of patients with upper urinary tract (UUT) tumors to evaluate the effectiveness of diagnostic procedures. This retrospective study evaluated tumor characteristics, imaging procedures, epidemiological and follow-up data of 113 patients. We analyzed the importance of non-invasive and endoscopic diagnosis in addition to imaging as well as the influence of stage and grade on recurrence rate. Most tumors were urothelial carcinomas (92.9%). The cardinal symptoms were hematuria (40.7%), flank pain (2.7%), and urinary obstruction (14.2%). Forty-seven patients received intravenous urograms (IVUs), 57 retrograde ureteropyelography (RUP), 89 CTs, 6 an MRI. The correct positive tumor identification was reached by IVU in 27/47 patients, by RUP in 50/57, by CT in 74/89, and by MRI in 3/6 patients representing sensitivities of 57.4% (IVU), 87.7% (RUP), 83.1% (CT), and 50% (MRI). Sixty-four patients had urine cytology, which was correctly positive in 60.9% and 56 had a diagnostic ureterorenoscopy, which was correctly positive in 83.9%. During follow-up more than 20% of patients developed a recurrence. In patients with hematuria and flank pain, UUT must be considered a differential diagnosis. UUT to the extent of 76.6% showed more invasive growth (>Ta). Thus, rapid and efficient diagnosis based primarily on imaging is required. Contrast CT scan seems to be the imaging modality with the best performance. However, often only a combination of diagnostic procedures gives a certain diagnosis. Due to the high recurrence rate, close follow-up is needed. © 2017 S. Karger AG, Basel.
Code of Federal Regulations, 2013 CFR
2013-10-01
... in the 80000 series of the Current Procedural Terminology published by the American Medical... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...
CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.
Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S
2018-02-01
To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Pablant, N A; Burrell, K H; Groebner, R J; Holcomb, C T; Kaplan, D H
2010-10-01
Results are presented from the B-Stark diagnostic installed on the DIII-D tokamak. This diagnostic provides measurements of the magnitude and direction of the internal magnetic field. The B-Stark system is a version of a motional Stark effect (MSE) diagnostic based on the relative line intensities and spacing of the Stark split D(α) emission from injected neutral beams. This technique may have advantages over MSE polarimetry based diagnostics in future devices, such as the ITER. The B-Stark diagnostic technique and calibration procedures are discussed. The system is shown to provide accurate measurements of B(θ)/B(T) and ∣B∣ over a range of plasma conditions. Measurements have been made with toroidal fields in the range of 1.2-2.1 T, plasma currents in the range 0.5-2.0 MA, densities between 1.7 and 9.0×10(19) m(-3), and neutral beam voltages between 50 and 81 keV. The viewing direction and polarization dependent transmission properties of the collection optics are found using an in situ beam into gas calibration. These results are compared to values found from plasma equilibrium reconstructions and the MSE polarimetry system on DIII-D.
Diagnostic Procedures for Detecting Nonlinear Relationships between Latent Variables
ERIC Educational Resources Information Center
Bauer, Daniel J.; Baldasaro, Ruth E.; Gottfredson, Nisha C.
2012-01-01
Structural equation models are commonly used to estimate relationships between latent variables. Almost universally, the fitted models specify that these relationships are linear in form. This assumption is rarely checked empirically, largely for lack of appropriate diagnostic techniques. This article presents and evaluates two procedures that can…
Droplet-based Biosensing for Lab-on-a-Chip, Open Microfluidics Platforms
Dak, Piyush; Ebrahimi, Aida; Swaminathan, Vikhram; Duarte-Guevara, Carlos; Bashir, Rashid; Alam, Muhammad A.
2016-01-01
Low cost, portable sensors can transform health care by bringing easily available diagnostic devices to low and middle income population, particularly in developing countries. Sample preparation, analyte handling and labeling are primary cost concerns for traditional lab-based diagnostic systems. Lab-on-a-chip (LoC) platforms based on droplet-based microfluidics promise to integrate and automate these complex and expensive laboratory procedures onto a single chip; the cost will be further reduced if label-free biosensors could be integrated onto the LoC platforms. Here, we review some recent developments of label-free, droplet-based biosensors, compatible with “open” digital microfluidic systems. These low-cost droplet-based biosensors overcome some of the fundamental limitations of the classical sensors, enabling timely diagnosis. We identify the key challenges that must be addressed to make these sensors commercially viable and summarize a number of promising research directions. PMID:27089377
Droplet-based Biosensing for Lab-on-a-Chip, Open Microfluidics Platforms.
Dak, Piyush; Ebrahimi, Aida; Swaminathan, Vikhram; Duarte-Guevara, Carlos; Bashir, Rashid; Alam, Muhammad A
2016-04-14
Low cost, portable sensors can transform health care by bringing easily available diagnostic devices to low and middle income population, particularly in developing countries. Sample preparation, analyte handling and labeling are primary cost concerns for traditional lab-based diagnostic systems. Lab-on-a-chip (LoC) platforms based on droplet-based microfluidics promise to integrate and automate these complex and expensive laboratory procedures onto a single chip; the cost will be further reduced if label-free biosensors could be integrated onto the LoC platforms. Here, we review some recent developments of label-free, droplet-based biosensors, compatible with "open" digital microfluidic systems. These low-cost droplet-based biosensors overcome some of the fundamental limitations of the classical sensors, enabling timely diagnosis. We identify the key challenges that must be addressed to make these sensors commercially viable and summarize a number of promising research directions.
Leppington, Charmody; Gleberzon, Brian; Fortunato, Lisa; Doucet, Nicolea; Vandervalk, Kyle
2012-01-01
Objective: The purpose of this study was to determine if diagnostic and therapeutic procedures for the cervical and cranial spine taught to students during the undergraduate program at Canadian Memorial Chiropractic College are required to be used during their internship by their supervising clinicians and, if so, to what extent these procedures are used. Methods: Course manuals and course syllabi from the Applied Chiropractic and Clinical Diagnosis faculty of the undergraduate chiropractic program for the academic year 2009–2010 were consulted and a list of all diagnostic and therapeutic procedures for the cranial and cervical spine was compiled. This survey asked clinicians to indicate if they themselves used or if they required the students they were supervising to use each procedure listed and, if so, to what extent each procedure was used. Demographic information of each clinician was also obtained. Results: In general, most diagnostic procedures of the head and neck were seldom used, with the exception of postural observation and palpation. By contrast, most cervical orthopaedic tests were often used, with the exception of tests for vertigo. Most therapeutic procedures were used frequently with the exception of prone cervical and “muscle” adjustments. Conclusion: There was a low degree of vertical integration for cranial procedures as compared to a much higher degree of vertical integration for cervical procedures between the undergraduate and clinical internship programs taught. Vertical integration is an important element of curricular planning and these results may be helpful to aid educators to more appropriately allocate classroom instruction PMID:22778531
NASA Technical Reports Server (NTRS)
Partridge, William P.; Laurendeau, Normand M.
1997-01-01
We have experimentally assessed the quantitative nature of planar laser-induced fluorescence (PLIF) measurements of NO concentration in a unique atmospheric pressure, laminar, axial inverse diffusion flame (IDF). The PLIF measurements were assessed relative to a two-dimensional array of separate laser saturated fluorescence (LSF) measurements. We demonstrated and evaluated several experimentally-based procedures for enhancing the quantitative nature of PLIF concentration images. Because these experimentally-based PLIF correction schemes require only the ability to make PLIF and LSF measurements, they produce a more broadly applicable PLIF diagnostic compared to numerically-based correction schemes. We experimentally assessed the influence of interferences on both narrow-band and broad-band fluorescence measurements at atmospheric and high pressures. Optimum excitation and detection schemes were determined for the LSF and PLIF measurements. Single-input and multiple-input, experimentally-based PLIF enhancement procedures were developed for application in test environments with both negligible and significant quench-dependent error gradients. Each experimentally-based procedure provides an enhancement of approximately 50% in the quantitative nature of the PLIF measurements, and results in concentration images nominally as quantitative as LSF point measurements. These correction procedures can be applied to other species, including radicals, for which no experimental data are available from which to implement numerically-based PLIF enhancement procedures.
Loeffler 4.0: Diagnostic Metagenomics.
Höper, Dirk; Wylezich, Claudia; Beer, Martin
2017-01-01
A new world of possibilities for "virus discovery" was opened up with high-throughput sequencing becoming available in the last decade. While scientifically metagenomic analysis was established before the start of the era of high-throughput sequencing, the availability of the first second-generation sequencers was the kick-off for diagnosticians to use sequencing for the detection of novel pathogens. Today, diagnostic metagenomics is becoming the standard procedure for the detection and genetic characterization of new viruses or novel virus variants. Here, we provide an overview about technical considerations of high-throughput sequencing-based diagnostic metagenomics together with selected examples of "virus discovery" for animal diseases or zoonoses and metagenomics for food safety or basic veterinary research. © 2017 Elsevier Inc. All rights reserved.
A vibration-based health monitoring program for a large and seismically vulnerable masonry dome
NASA Astrophysics Data System (ADS)
Pecorelli, M. L.; Ceravolo, R.; De Lucia, G.; Epicoco, R.
2017-05-01
Vibration-based health monitoring of monumental structures must rely on efficient and, as far as possible, automatic modal analysis procedures. Relatively low excitation energy provided by traffic, wind and other sources is usually sufficient to detect structural changes, as those produced by earthquakes and extreme events. Above all, in-operation modal analysis is a non-invasive diagnostic technique that can support optimal strategies for the preservation of architectural heritage, especially if complemented by model-driven procedures. In this paper, the preliminary steps towards a fully automated vibration-based monitoring of the world’s largest masonry oval dome (internal axes of 37.23 by 24.89 m) are presented. More specifically, the paper reports on signal treatment operations conducted to set up the permanent dynamic monitoring system of the dome and to realise a robust automatic identification procedure. Preliminary considerations on the effects of temperature on dynamic parameters are finally reported.
Prosthetic joint infection development of an evidence-based diagnostic algorithm.
Mühlhofer, Heinrich M L; Pohlig, Florian; Kanz, Karl-Georg; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; Kelch, Sarah; Harrasser, Norbert; von Eisenhart-Rothe, Rüdiger; Schauwecker, Johannes
2017-03-09
Increasing rates of prosthetic joint infection (PJI) have presented challenges for general practitioners, orthopedic surgeons and the health care system in the recent years. The diagnosis of PJI is complex; multiple diagnostic tools are used in the attempt to correctly diagnose PJI. Evidence-based algorithms can help to identify PJI using standardized diagnostic steps. We reviewed relevant publications between 1990 and 2015 using a systematic literature search in MEDLINE and PUBMED. The selected search results were then classified into levels of evidence. The keywords were prosthetic joint infection, biofilm, diagnosis, sonication, antibiotic treatment, implant-associated infection, Staph. aureus, rifampicin, implant retention, pcr, maldi-tof, serology, synovial fluid, c-reactive protein level, total hip arthroplasty (THA), total knee arthroplasty (TKA) and combinations of these terms. From an initial 768 publications, 156 publications were stringently reviewed. Publications with class I-III recommendations (EAST) were considered. We developed an algorithm for the diagnostic approach to display the complex diagnosis of PJI in a clear and logically structured process according to ISO 5807. The evidence-based standardized algorithm combines modern clinical requirements and evidence-based treatment principles. The algorithm provides a detailed transparent standard operating procedure (SOP) for diagnosing PJI. Thus, consistently high, examiner-independent process quality is assured to meet the demands of modern quality management in PJI diagnosis.
2012-01-01
Background Clinical pathways (CPs) are used to improve the outcomes of acute stroke, but their use in stroke care is questionable, because the evidence on their effectiveness is still inconclusive. The objective of this study was to evaluate whether CPs improve the outcomes and the quality of care provided to patients after acute ischemic stroke. Methods This was a multicentre cluster-randomized trial, in which 14 hospitals were randomized to the CP arm or to the non intervention/usual care (UC) arm. Healthcare workers in the CP arm received 3 days of training in quality improvement of CPs and in use of a standardized package including information on evidence-based key interventions and indicators. Healthcare workers in the usual-care arm followed their standard procedures. The teams in the CP arm developed their CPs over a 6-month period. The primary end point was mortality. Secondary end points were: use of diagnostic and therapeutic procedures, implementation of organized care, length of stay, re-admission and institutionalization rates after discharge, dependency levels, and complication rates. Results Compared with the patients in the UC arm, the patients in the CP arm had a significantly lower risk of mortality at 7 days (OR = 0.10; 95% CI 0.01 to 0.95) and significantly lower rates of adverse functional outcomes, expressed as the odds of not returning to pre-stroke functioning in their daily life (OR = 0.42; 95 CI 0.18 to 0.98). There was no significant effect on 30-day mortality. Compared with the UC arm, the hospital diagnostic and therapeutic procedures were performed more appropriately in the CP arm, and the evidence-based key interventions and organized care were more applied in the CP arm. Conclusions CPs can significantly improve the outcomes of patients with ischemic patients with stroke, indicating better application of evidence-based key interventions and of diagnostic and therapeutic procedures. This study tested a new hypothesis and provided evidence on how CPs can work. Trial registration ClinicalTrials.gov ID: [NCT00673491]. PMID:22781160
Goyal, Abhishek; Gupta, Dheeraj; Agarwal, Ritesh; Bal, Amanjit; Nijhawan, Raje; Aggarwal, Ashutosh N
2014-07-01
The exact position of routine bronchoscopic sampling techniques in diagnostic workup of sarcoidosis is often debated. Herein, we ascertain the role of transbronchial needle aspiration (TBNA), endobronchial ultrasound-guided TBNA (EBUS-TBNA), transbronchial lung biopsy (TBLB), and endobronchial biopsy (EBB) in diagnosis of sarcoidosis. Consecutive patients with suspected sarcoidosis who underwent fiberoptic bronchoscopy were studied. TBLB, EBB, TBNA, or EBUS-TBNA was performed as indicated in a standardized manner. A diagnosis of sarcoidosis was established based on the finding of non-necrotizing granulomas or on clinical grounds at 6-month follow-up. Individual and cumulative yield of various procedures and their correlation with clinicoradiologic parameters was analyzed. Of the 164 patients studied, 151 were finally diagnosed as sarcoidosis. Granulomas were demonstrated in 127 (84.2%) patients. Diagnostic yield of TBLB, EBB, TBNA, and EBUS-TBNA was 68.7%, 49.6%, 22.43%, and 57.1%, respectively. Cumulative yields of various procedures were: EBB+TBLB 81.4%; TBLB+TBNA 73.7%; TBNA+EBB 62.9%; TBLB+EBB+TBNA 86.9%; and TBLB+EBB+EBUS-TBNA 86.4%. In those with visible mucosal abnormalities, TBLB+EBB conferred the highest diagnostic yield (92.8%). Clinical findings or radiologic stage had no impact on diagnostic yield. TBLB is an important tool in bronchoscopic diagnosis of sarcoidosis. If endobronchial abnormalities are seen during bronchoscopy, TBLB with EBB gives the best results otherwise TBLB combined with conventional TBNA and EBB or EBUS-TBNA are required to maximize the diagnostic yield.
Quantification of Gear Tooth Damage by Optimal Tracking of Vibration Signatures
NASA Technical Reports Server (NTRS)
Choy, F. K.; Veillette, R. J.; Polyshchuk, V.; Braun, M. J.; Hendricks, R. C.
1996-01-01
This paper presents a technique for quantifying the wear or damage of gear teeth in a transmission system. The procedure developed in this study can be applied as a part of either an onboard machine health-monitoring system or a health diagnostic system used during regular maintenance. As the developed methodology is based on analysis of gearbox vibration under normal operating conditions, no shutdown or special modification of operating parameters is required during the diagnostic process. The process of quantifying the wear or damage of gear teeth requires a set of measured vibration data and a model of the gear mesh dynamics. An optimization problem is formulated to determine the profile of a time-varying mesh stiffness parameter for which the model output approximates the measured data. The resulting stiffness profile is then related to the level of gear tooth wear or damage. The procedure was applied to a data set generated artificially and to another obtained experimentally from a spiral bevel gear test rig. The results demonstrate the utility of the procedure as part of an overall health-monitoring system.
[Dual Antiplatelet Therapy in the Perioperative Period - To Continue or Discontinue Treatment?
Koscielny, Jürgen; von Heymann, Christian; Zeymer, Uwe; Cremer, Jochen; Spannagl, Michael; Labenz, Joachim; Giannitsis, Evangelos; Goss, Franz
2017-08-01
Background For secondary prevention of acute coronary syndrome, guidelines recommend dual antiplatelet therapy (DAPT) with acetylsalicylic acid and a P2Y12 receptor antagonist such as clopidogrel, prasugrel or ticagrelor for a period of 12 months. Often, uncertainty exists with respect to surgical or diagnostic procedures in these high-risk patients: can the DAPT be continued without interruption? If not, what is the recommended withdrawal strategy? What should be considered for the perioperative management? Methods An interdisciplinary group of experienced experts in the fields of cardiology, cardiac surgery, gastroenterology, anaesthesiology, intensive care and haemostaseology developed recommendations relevant to daily clinical practice based on the current scientific evidence. Results These recommendations include instructions for evaluating the patient- and procedure-specific risks of bleeding and ischaemia, general recommendations regarding the DAPT withdrawal strategy, and specific guidance for frequent surgical or diagnostic procedures. Discussion This article aims to facilitate the management of patients with DAPT for all medical disciplines involved, thereby ensuring optimal care of patients during the perioperative period. © Georg Thieme Verlag KG Stuttgart · New York.
21 CFR 886.1380 - Diagnostic condensing lens.
Code of Federal Regulations, 2010 CFR
2010-04-01
... light from the fundus of the eye. (b) Classification. Class I (general controls). The device is exempt...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...
Vikraman, Seneesh Kumar; Chandra, Vipin; Balakrishnan, Bijoy; Batra, Meenu; Sethumadhavan, Sreeja; Patil, Swapneel Neelkanth; Nair, Sabila; Kannoly, Gopinathan
2017-05-01
The primary objective our study was to assess the role of diagnostic antepartum amnioinfusion on the yield from targeted ultrasounds performed in pregnancies with severe oligo- and anhydramnios. This was a retrospective and descriptive study, conducted in the fetal medicine units of two private tertiary care referral centers in south India. The details of all the cases of diagnostic amnioinfusion performed at these two centers from January 2009 to June 2016 were collected and analyzed. Inclusion criteria were pregnancies between 17 and 26 weeks of gestational age with severe oligo- or anhydramnios. Pregnancies with obvious preterm premature rupture of membranes (PPROM) were excluded. The primary outcome measure was the improvement in diagnostic information pertaining to cause of severe oligo- and anhydramnios, and the nature of such anomalies. A total of 61 cases of were identified. The median gestational age at performance of the procedure was 22 weeks [IQR, 19.5-23]. The mean volume of normal saline infused was 314±54ml. A significant increase in the single vertical pocket (SVP) was observed following the procedure (pre-procedure SVP=0.6±0.9cm, post procedure SVP=3.4±1.7; paired t test, p<0.001). In 37 cases (37/61, 60.7%), there were no pre-procedure ultrasound findings. There was significant overall detection of abnormalities post procedure (mean pre-procedure findings=0.39±0.49, mean post procedure findings=1.59±1.24; paired t test, p<0.001). The most frequent group of anomalies/abnormalities were renal (36/61, 59%), followed by PPROM (13/61, 21.3%) and finally fetal growth restriction (11/61, 18%). Antepartum amnioinfusion is a valuable ancillary technique in prenatal diagnosis as it increases the diagnostic yield from pregnancies presenting with severe oligo- and anhydramnios. Copyright © 2017 Elsevier B.V. All rights reserved.
Sáez, Carlos; Martí-Bonmatí, Luis; Alberich-Bayarri, Angel; Robles, Montserrat; García-Gómez, Juan M
2014-02-01
The results of a randomized pilot study and qualitative evaluation of the clinical decision support system Curiam BT are reported. We evaluated the system's feasibility and potential value as a radiological information procedure complementary to magnetic resonance (MR) imaging to assist novice radiologists in diagnosing brain tumours using MR spectroscopy (1.5 and 3.0T). Fifty-five cases were analysed at three hospitals according to four non-exclusive diagnostic questions. Our results show that Curiam BT improved the diagnostic accuracy in all the four questions. Additionally, we discuss the findings of the users' feedback about the system, and the further work to optimize it for real environments and to conduct a large clinical trial. © 2013 Published by Elsevier Ltd.
Lentz, Robert J; Argento, A Christine; Colby, Thomas V; Rickman, Otis B; Maldonado, Fabien
2017-07-01
Transbronchial lung biopsy with a cryoprobe, or cryobiopsy, is a promising new bronchoscopic biopsy technique capable of obtaining larger and better-preserved samples than previously possible using traditional biopsy forceps. Over two dozen case series and several small randomized trials are now available describing experiences with this technique, largely for the diagnosis of diffuse parenchymal lung disease (DPLD), in which the reported diagnostic yield is typically 70% to 80%. Cryobiopsy technique varies widely between centers and this predominantly single center-based retrospective literature heterogeneously defines diagnostic yield and complications, limiting the degree to which this technique can be compared between centers or to surgical lung biopsy (SLB). This review explores the broad range of cryobiopsy techniques currently in use, their rationale, the current state of the literature, and suggestions for the direction of future study into this promising but unproven procedure.
Using the arthroscopic surgery skill evaluation tool as a pass-fail examination.
Koehler, Ryan J; Nicandri, Gregg T
2013-12-04
Examination of arthroscopic skill requires evaluation tools that are valid and reliable with clear criteria for passing. The Arthroscopic Surgery Skill Evaluation Tool was developed as a video-based assessment of technical skill with criteria for passing established by a panel of experts. The purpose of this study was to test the validity and reliability of the Arthroscopic Surgery Skill Evaluation Tool as a pass-fail examination of arthroscopic skill. Twenty-eight residents and two sports medicine faculty members were recorded performing diagnostic knee arthroscopy on a left and right cadaveric specimen in our arthroscopic skills laboratory. Procedure videos were evaluated with use of the Arthroscopic Surgery Skill Evaluation Tool by two raters blind to subject identity. Subjects were considered to pass the Arthroscopic Surgery Skill Evaluation Tool when they attained scores of ≥ 3 on all eight assessment domains. The raters agreed on a pass-fail rating for fifty-five of sixty videos rated with an interclass correlation coefficient value of 0.83. Ten of thirty participants were assigned passing scores by both raters for both diagnostic arthroscopies performed in the laboratory. Receiver operating characteristic analysis demonstrated that logging more than eighty arthroscopic cases or performing more than thirty-five arthroscopic knee cases was predictive of attaining a passing Arthroscopic Surgery Skill Evaluation Tool score on both procedures performed in the laboratory. The Arthroscopic Surgery Skill Evaluation Tool is valid and reliable as a pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. This study demonstrates that the Arthroscopic Surgery Skill Evaluation Tool may be a useful tool for pass-fail examination of diagnostic arthroscopy of the knee in the simulation laboratory. Further study is necessary to determine whether the Arthroscopic Surgery Skill Evaluation Tool can be used for the assessment of multiple arthroscopic procedures and whether it can be used to evaluate arthroscopic procedures performed in the operating room.
Trends in radiation exposure from clinical nuclear medicine procedures in Shanghai, China.
Yi, Yanling; Zheng, Junzheng; Zhuo, Weihai; Gao, Linfeng
2012-03-01
This study was designed to assess the trends in the frequencies of nuclear medicine procedures in Shanghai, China, and to determine their contributions to the per capita effective dose to the Shanghai population. The mean activities of radionuclides administered by nuclear medicine departments were compared with the Chinese national guidelines on diagnostic reference levels. On the basis of the three surveys carried out by Shanghai Municipal Center for Disease Control and Prevention in 1996, 1998, and 2008, the typically administered radiopharmaceuticals, levels of activity, the number of procedures, and population were systematically analyzed to assess the frequencies of nuclear medicine procedures and the per capita effective dose. The frequencies were approximately 2.77, 3.46, and 6.63 per 1000 people in 1996, 1998, and 2008, respectively. The annual per capita doses from diagnostic nuclear medicine were estimated to be 0.016, 0.022, and 0.032 mSv in 1996, 1998, and 2008, respectively. The annual frequency of therapeutic nuclear medicine procedures increased from 0.131 to 0.430 per 1000 people in the intervening 12 years. In the 12 years before 2008, diagnostic and therapeutic procedures in nuclear medicine in Shanghai increased continuously, and the annual per capita dose doubled. Increases in PET imaging and bone scans were the major contributors to the increasing frequency and magnitude of radiation exposure to the population. The activities administered for most diagnostic procedures were generally consistent with the designated reference levels.
ERIC Educational Resources Information Center
Bowe, Melissa; Sellers, Tyra P.
2018-01-01
The Performance Diagnostic Checklist-Human Services (PDC-HS) has been used to assess variables contributing to undesirable staff performance. In this study, three preschool teachers completed the PDC-HS to identify the factors contributing to four paraprofessionals' inaccurate implementation of error-correction procedures during discrete trial…
42 CFR 413.122 - Payment for hospital outpatient radiology services and other diagnostic procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 2 2010-10-01 2010-10-01 false Payment for hospital outpatient radiology services... radiology services and other diagnostic procedures. (a) Basis and purpose. (1) This section implements section 1833(n) of the Act and establishes the method for determining Medicare payments for radiology...
IMBLMS phase B4, additional tasks 5.0. Microbial identification system
NASA Technical Reports Server (NTRS)
1971-01-01
A laboratory study was undertaken to provide simplified procedures leading to the presumptive identification (I/D) of defined microorganisms on-board an orbiting spacecraft. Identifications were to be initiated by nonprofessional bacteriologists, (crew members) on a contingency basis only. Key objectives/constraints for this investigation were as follows:(1) I/D procedures based on limited, defined diagnostic tests, (2) testing oriented about ten selected microorganisms, (3) provide for definitive I/D key and procedures per selected organism, (4) define possible occurrences of false positives for the resulting I/D key by search of the appropriate literature, and (5) evaluation of the I/D key and procedure through a limited field trial on randomly selected subjects using the I/D key.
Towards increase of diagnostic efficacy in gynecologic OCT
NASA Astrophysics Data System (ADS)
Kirillin, Mikhail; Panteleeva, Olga; Eliseeva, Darya; Kachalina, Olga; Sergeeva, Ekaterina; Dubasova, Lyubov; Agrba, Pavel; Mikailova, Gyular; Prudnikov, Maxim; Shakhova, Natalia
2013-06-01
Gynecologic applications of optical coherence tomography (OCT) are usually performed in combination with routine diagnostic procedures: laparoscopy and colposcopy. In combination with laparoscopy OCT is employed for inspection of fallopian tubes in cases of unrecognized infertility while in colposcopy it is used to identify cervix pathologies including cancer. In this paper we discuss methods for increasing diagnostic efficacy of OCT application in these procedures. For OCT-laparoscopy we demonstrate independent criteria for pathology recognition which allow to increase accuracy of diagnostics. For OCT-colposcopy we report on application of device for controlled compression allowing to sense the elasticity of the inspected cervix area and distinguish between neoplasia and inflammatory processes.
MO-DE-304-02: Diagnostic Workforce Subcommittee Status and Direction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gress, D.
2015-06-15
The Abt study of medical physicist work values for radiation oncology physics services, Round IV is completed. It supersedes the Abt III study of 2008. The 2015 Abt study measured qualified medical physicist (QMP) work associated with routine radiation oncology procedures as well as some special procedures. As before, a work model was created to allow the medical physicist to defend QMP work based on both routine and special procedures service mix. The work model can be used to develop a cost justification report for setting charges for radiation oncology physics services. The Abt study Round IV was designed tomore » empower the medical physicist to negotiate a service or employment contract with providers based on measured national QMP workforce and staffing data. For a variety of reasons, the diagnostic imaging contingent of AAPM has had a more difficult time trying estimate workforce requirements than their therapy counterparts. Over the past several years, the Diagnostic Work and Workforce Study Subcommittee (DWWSS) has collected survey data from AAPM members, but the data have been very difficult to interpret. The DWWSS has reached out to include more AAPM volunteers to create a more full and accurate representation of actual clinical practice models on the subcommittee. Though much work remains, through hours of discussion and brainstorming, the DWWSS has somewhat of a clear path forward. This talk will provide attendees with an update on the efforts of the subcommittee. Learning Objectives: Understand the new information documented in the Abt studies. Understand how to use the Abt studies to justify medical physicist staffing. Learn relevant historical information on imaging physicist workforce. Understand the process of the DWWSS in 2014. Understand the intended path forward for the DWWSS.« less
ERIC Educational Resources Information Center
Dietrich, Susanne; Hertrich, Ingo; Riedel, Andreas; Ackermann, Hermann
2012-01-01
The Asperger syndrome (AS) includes impaired recognition of other people's mental states. Since language-based diagnostic procedures may be confounded by cognitive-linguistic compensation strategies, nonverbal test materials were created, including human affective and vegetative sounds. Depending on video context, each sound could be interpreted…
Exploring Genome-Wide Expression Profiles Using Machine Learning Techniques.
Kebschull, Moritz; Papapanou, Panos N
2017-01-01
Although contemporary high-throughput -omics methods produce high-dimensional data, the resulting wealth of information is difficult to assess using traditional statistical procedures. Machine learning methods facilitate the detection of additional patterns, beyond the mere identification of lists of features that differ between groups.Here, we demonstrate the utility of (1) supervised classification algorithms in class validation, and (2) unsupervised clustering in class discovery. We use data from our previous work that described the transcriptional profiles of gingival tissue samples obtained from subjects suffering from chronic or aggressive periodontitis (1) to test whether the two diagnostic entities were also characterized by differences on the molecular level, and (2) to search for a novel, alternative classification of periodontitis based on the tissue transcriptomes.Using machine learning technology, we provide evidence for diagnostic imprecision in the currently accepted classification of periodontitis, and demonstrate that a novel, alternative classification based on differences in gingival tissue transcriptomes is feasible. The outlined procedures allow for the unbiased interrogation of high-dimensional datasets for characteristic underlying classes, and are applicable to a broad range of -omics data.
Lennon, Anne Marie; Kapoor, Sumit; Khashab, Mouen; Corless, Erin; Amateau, Stuart; Dunbar, Kerry; Chandrasekhara, Vinay; Singh, Vikesh; Okolo, Patrick I
2012-05-01
Endoscopic retrograde cholangiopancreatography (ERCP) is often unsuccessful in patients with Roux-en-Y anatomy. Augmented enteroscopy allows deep insertion into the small bowel and can be useful in patients with Roux-en-Y anatomy. The aim of this study was to compare single balloon assisted ERCP (SBE-ERCP) and spiral assisted ERCP (SE-ERCP) in patients with Roux-en-Y anatomy in terms of diagnostic and therapeutic yield, procedure time, and complications. This is a retrospective cohort study of consecutive patients with Roux-en-Y anatomy who underwent SBE-ERCP or SE-ERCP between October 2007 and March 2011. Diagnostic yield was defined as successful duct cannulation. Therapeutic yield was defined as the ability to successfully carry out endoscopic therapy in those cannulated. Procedure time and complications were assessed. Thirty-four consecutive patients with Roux-en-Y anatomy underwent 54 ERCP procedures. The overall diagnostic yield was 44.4% with no significant difference between the diagnostic yield of SBE-ERCP (48.3%) and SE-ERCP (40%). The diagnostic yield was lower in patients with gastric by-pass (38.9%) compared with other types of Roux-en-Y anatomy (47.2%) but this was not statistically significant (P = 0.772). The overall therapeutic yield was 93.8%, with a therapeutic yield of 100% for SBE-ERCP and 87.5% for SE-ERCP (P = 1.0). There was one perforation during SBE-ERCP, giving a complication rate of 3.5%. The mean procedure time did not differ between the two techniques. Diagnostic and therapeutic yields are similar with SBE-ERCP and SE-ERCP in patients with Roux-en-Y anatomy with no significant difference in procedure time or complication rates.
Creation of a diagnostic wait times measurement framework based on evidence and consensus.
Gilbert, Julie E; Dobrow, Mark J; Kaan, Melissa; Dobranowski, Julian; Srigley, John R; Jusko Friedman, Audrey; Irish, Jonathan C
2014-09-01
Public reporting of wait times worldwide has to date focused largely on treatment wait times and is limited in its ability to capture earlier parts of the patient journey. The interval between suspicion and diagnosis or ruling out of cancer is a complex phase of the cancer journey. Diagnostic delays and inefficient use of diagnostic imaging procedures can result in poor patient outcomes, both physical and psychosocial. This study was designed to develop a framework that could be adopted for multiple disease sites across different jurisdictions to enable the measurement of diagnostic wait times and diagnostic delay. Diagnostic benchmarks and targets in cancer systems were explored through a targeted literature review and jurisdictional scan. Cancer system leaders and clinicians were interviewed to validate the information found in the jurisdictional scan. An expert panel was assembled to review and, through a modified Delphi consensus process, provide feedback on a diagnostic wait times framework. The consensus process resulted in agreement on a measurement framework that identified suspicion, referral, diagnosis, and treatment as the main time points for measuring this critical phase of the patient journey. This work will help guide initiatives designed to improve patient access to health services by developing an evidence-based approach to standardization of the various waypoints during the diagnostic pathway. The diagnostic wait times measurement framework provides a yardstick to measure the performance of programs that are designed to manage and expedite care processes between referral and diagnosis or ruling out of cancer. Copyright © 2014 by American Society of Clinical Oncology.
Pettit, K E; Hull, A D; Korty, L; Jones, M C; Pretorius, D H
2014-10-01
To characterize the patient population utilizing circulating cell-free fetal DNA (ccffDNA) testing at a large academic center and evaluate trends in the performance of invasive diagnostic procedures. A retrospective cohort study of all patients who underwent cell-free DNA testing from May to December 2012 was performed. During the study period, 206 patients had cell-free DNA testing. Of those, 75% (155/206) were of ages ⩾ 35 years. Of those undergoing ccffDNA testing, 41% had positive aneuploidy screening and 38% had abnormal ultrasound findings. Only 7% of the patients with negative ccffDNA testing opted for an invasive diagnostic procedure compared with 60% with positive testing (P<0.01). The rate of invasive procedures decreased from 5.9% of all visits to the center during a similar 8-month period in 2010 to 4.1% of all visits during the study period (P<0.01). Our data suggest that ccffDNA testing leads to reduced uptake of invasive procedures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy
2012-11-15
Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measuremore » of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was Less-Than-Or-Slanted-Equal-To 3 mm (95th percentiles within {+-}4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from -0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of Less-Than-Or-Slanted-Equal-To 5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance.« less
Pursley, Jennifer; Risholm, Petter; Fedorov, Andriy; Tuncali, Kemal; Fennessy, Fiona M.; Wells, William M.; Tempany, Clare M.; Cormack, Robert A.
2012-01-01
Purpose: This study introduces a probabilistic nonrigid registration method for use in image-guided prostate brachytherapy. Intraoperative imaging for prostate procedures, usually transrectal ultrasound (TRUS), is typically inferior to diagnostic-quality imaging of the pelvis such as endorectal magnetic resonance imaging (MRI). MR images contain superior detail of the prostate boundaries and provide substructure features not otherwise visible. Previous efforts to register diagnostic prostate images with the intraoperative coordinate system have been deterministic and did not offer a measure of the registration uncertainty. The authors developed a Bayesian registration method to estimate the posterior distribution on deformations and provide a case-specific measure of the associated registration uncertainty. Methods: The authors adapted a biomechanical-based probabilistic nonrigid method to register diagnostic to intraoperative images by aligning a physician's segmentations of the prostate in the two images. The posterior distribution was characterized with a Markov Chain Monte Carlo method; the maximum a posteriori deformation and the associated uncertainty were estimated from the collection of deformation samples drawn from the posterior distribution. The authors validated the registration method using a dataset created from ten patients with MRI-guided prostate biopsies who had both diagnostic and intraprocedural 3 Tesla MRI scans. The accuracy and precision of the estimated posterior distribution on deformations were evaluated from two predictive distance distributions: between the deformed central zone-peripheral zone (CZ-PZ) interface and the physician-labeled interface, and based on physician-defined landmarks. Geometric margins on the registration of the prostate's peripheral zone were determined from the posterior predictive distance to the CZ-PZ interface separately for the base, mid-gland, and apical regions of the prostate. Results: The authors observed variation in the shape and volume of the segmented prostate in diagnostic and intraprocedural images. The probabilistic method allowed us to convey registration results in terms of posterior distributions, with the dispersion providing a patient-specific estimate of the registration uncertainty. The median of the predictive distance distribution between the deformed prostate boundary and the segmented boundary was ⩽3 mm (95th percentiles within ±4 mm) for all ten patients. The accuracy and precision of the internal deformation was evaluated by comparing the posterior predictive distance distribution for the CZ-PZ interface for each patient, with the median distance ranging from −0.6 to 2.4 mm. Posterior predictive distances between naturally occurring landmarks showed registration errors of ⩽5 mm in any direction. The uncertainty was not a global measure, but instead was local and varied throughout the registration region. Registration uncertainties were largest in the apical region of the prostate. Conclusions: Using a Bayesian nonrigid registration method, the authors determined the posterior distribution on deformations between diagnostic and intraprocedural MR images and quantified the uncertainty in the registration results. The feasibility of this approach was tested and results were positive. The probabilistic framework allows us to evaluate both patient-specific and location-specific estimates of the uncertainty in the registration result. Although the framework was tested on MR-guided procedures, the preliminary results suggest that it may be applied to TRUS-guided procedures as well, where the addition of diagnostic MR information may have a larger impact on target definition and clinical guidance. PMID:23127078
Bernier, Marie Odile; Doody, Michele M; Van Dyke, Miriam E; Villoing, Daphné; Alexander, Bruce H; Linet, Martha S; Kitahara, Cari M
2018-05-02
Technologists working in nuclear medicine (NM) are exposed to higher radiation doses than most other occupationally exposed populations. The aim of this study was to estimate the risk of cancer in NM technologists in relation to work history, procedures performed and radioprotection practices. From the US Radiologic Technologists cohort study, 72 755 radiologic technologists who completed a 2003-2005 questionnaire were followed for cancer mortality through 31 December 2012 and for cancer incidence through completion of a questionnaire in 2012-2013. Multivariable-adjusted models were used to estimate HRs for total cancer incidence and mortality by history of ever performing NM procedures and frequency of performing specific diagnostic or therapeutic NM procedures and associated radiation protection measures by decade. During follow-up (mean=7.5 years), 960 incident cancers and 425 cancer deaths were reported among the 22 360 technologists who worked with NM procedures. We observed no increased risk of cancer incidence (HR 0.96, 95% CI 0.89 to 1.04) or death (HR 1.05, 95% CI 0.93 to 1.19) among workers who ever performed NM procedures. HRs for cancer incidence but not mortality were higher for technologists who began performing therapeutic procedures in 1960 and later compared with the 1950s. Frequency of performing diagnostic or therapeutic NM procedures and use of radioprotection measures were not consistently associated with cancer risk. No clear associations were observed for specific cancers, but results were based on small numbers. Cancer incidence and mortality were not associated with NM work history practices, including greater frequency of procedures performed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
[The role of multidetector computer tomography in diagnosis of acute pancreatitis].
Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M
2014-10-01
With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.
Transtracheal aspiration in the diagnosis of pulmonary blastomycosis (17 cases: 2000–2005)
McMillan, Chantal J.; Taylor, Susan M.
2008-01-01
Blastomyces dermatitidis is a common etiologic agent of fungal pneumonia in dogs. Definitive diagnosis is based on cytologic demonstration of the organism in affected tissues. Fluid obtained through transtracheal aspiration has previously been reported to have a low diagnostic yield for B. dermatitidis organisms. This retrospective study identified B. dermatitidis organisms in 76% of samples when transtracheal aspiration was performed in 17 nonsedated dogs with pulmonary blastomycosis. Transtracheal aspiration is a noninvasive and simple procedure that should be considered as an early diagnostic test whenever blastomycosis is a differential diagnosis in dogs with pulmonary disease. PMID:18320978
Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh
2015-07-01
The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.
Mean estimation in highly skewed samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pederson, S P
The problem of inference for the mean of a highly asymmetric distribution is considered. Even with large sample sizes, usual asymptotics based on normal theory give poor answers, as the right-hand tail of the distribution is often under-sampled. This paper attempts to improve performance in two ways. First, modifications of the standard confidence interval procedure are examined. Second, diagnostics are proposed to indicate whether or not inferential procedures are likely to be valid. The problems are illustrated with data simulated from an absolute value Cauchy distribution. 4 refs., 2 figs., 1 tab.
The modern trends of the evolution laser information technology in oncology
NASA Astrophysics Data System (ADS)
Mikov, A. A.; Svirin, V. N.
2008-04-01
Laser-optical information technologies and devices develop since the 70- years at the end of 20 century and are broadly used for diagnostics and treatment of oncological diseases to date. Although such methods as photodynamic therapy (PDT), laser-induce thermotherapy (LITT), fluorescent diagnostics and spectrophotometry already more than 30 years are used for treatment and diagnostics of oncological diseases, nevertheless, they are enough new methods and, as a rule, are used in large scientific centers and medical institutions. This is bound, first of all, with lack of information on modern method of cancer treatment, the absence of widely available laser procedures and corresponding devices in the polyclinics and even in district hospitals, as well as insufficient understanding of application areas, where laser methods has an advantage by comparison, for instance, with beam or chemotherapy. At present day laser methods are fast upcoming direction of the treatment oncological diseases. This is explained by progress in development essentially laser, particularly diode, improvement electronic and computing components and broad introduction software-algorithmic methods of control the undertaking therapeutic and diagnostic procedures. In article are considered new laser methods of the undertaking diagnostic and therapeutic procedures and is shown that introduction multiwave laser radiation for probe and influences on tissue, the different methods of the determination of the functional state of tissues, realization of the on-line diagnostics when carrying out the therapeutic procedures, automatic control systems of the power laser radiation, which depends on state patient tissue, as well as software-algorithmic methods of management session therapeutic and diagnostic procedures greatly raises efficiency of the treatment oncological diseases. On an example of the multipurpose laser therapeutic devices("MLTA") developed and introduced in clinical practice and multipurpose laser diagnostic complexes ("MLDC"), the realizing offered methods, are shown the basic tendencies of development laser methods in oncology, concrete technical decisions and the experimental clinical material showing increase of efficiency of treatment of a cancer at their realization are resulted. It is shown, that realization of the offered methods and technical technologies opens new competitive advantages laser technologies in comparison with beam and chemical-therapy at treatment of oncological diseases.
ERIC Educational Resources Information Center
International Labour Office, Islamabad (Pakistan). Asian and Pacific Skill Development Programme.
This screening and diagnostic procedure is intended to identify Level 1 adults with specific learning problems. The adults not meeting criteria on the assessments for visual and auditory functions should be referred to proper medical services for full evaluations. A prescriptive teaching program should be specifically designed to meet needs of…
Efficacy and economic impact evaluation of a navigation system for assisted lung biopsy
Giannatiempo, Sara; Petitti, Tommasangelo; Zobel, Bruno B.; Grasso, Rosario F.; Guglielmelli, Eugenio
2018-01-01
This Letter reports on the testing and assessment of an optical computed tomography-navigation system for percutaneous lung interventional, SIRIO, showing how the lesion diameter affects the bioptic procedure. Clinical data, relating to 501 patients, were collected at the Department of Interventional Radiology of Policlinico Universitario Campus Bio-Medico. This Letter shows that the diameter of lesion affects only the procedure duration (50.91 ± 18.87 min for lesions of diameter ≤20 mm and 44.98 ± 19.43 min for lesions of diameter >20 and ≤40 mm). For the nodules with a diameter ≤20 mm, there is a significant increase in the duration of the procedure (for each mm less the time increases by 6 s). Other parameters like the mean effective radiation dose and the presence of a diagnostic or non-diagnostic specimen do not depend, instead, on the lesion size. The economic analysis based on the biopsy procedure with SIRIO shows the necessity to adopt a new reimbursement system for percutaneous biopsy performed using navigation systems to stimulate their use to get important non-economic gains such as early diagnosis, reduction of the absorbed dose of X-rays and increasing number of lung cancers in a curable early stage. PMID:29750112
Efficacy and economic impact evaluation of a navigation system for assisted lung biopsy.
Giannatiempo, Sara; Carpino, Giorgio; Petitti, Tommasangelo; Zobel, Bruno B; Grasso, Rosario F; Guglielmelli, Eugenio
2018-04-01
This Letter reports on the testing and assessment of an optical computed tomography-navigation system for percutaneous lung interventional, SIRIO, showing how the lesion diameter affects the bioptic procedure. Clinical data, relating to 501 patients, were collected at the Department of Interventional Radiology of Policlinico Universitario Campus Bio-Medico. This Letter shows that the diameter of lesion affects only the procedure duration (50.91 ± 18.87 min for lesions of diameter ≤20 mm and 44.98 ± 19.43 min for lesions of diameter >20 and ≤40 mm). For the nodules with a diameter ≤20 mm, there is a significant increase in the duration of the procedure (for each mm less the time increases by 6 s). Other parameters like the mean effective radiation dose and the presence of a diagnostic or non-diagnostic specimen do not depend, instead, on the lesion size. The economic analysis based on the biopsy procedure with SIRIO shows the necessity to adopt a new reimbursement system for percutaneous biopsy performed using navigation systems to stimulate their use to get important non-economic gains such as early diagnosis, reduction of the absorbed dose of X-rays and increasing number of lung cancers in a curable early stage.
Patients with environment-related disorders: comprehensive results of interdisciplinary diagnostics.
Brand, Serge; Heller, Pia; Bircher, Andreas J; Braun-Fahrleander, Charlotte; Huss, Anke; Niederer, Markus; Schwarzenbach, Simone; Waeber, Roger; Wegmann, Lukas; Kuechenhoff, Joachim
2009-03-01
Researchers dealing with environmental illnesses face complex diagnostic and methodological difficulties. Poor objective findings contrast with high subjective suffering and a firm belief that environmental exposure is the only source of complaints. The Basel pilot research project established a multi-modal assessment procedure and assessed complaints attributed to the environment. Medical, psychological and environmental findings were evaluated as to their pathogenic validity. Furthermore, patients were pooled into distinguishable subgroups in order to formulate more appropriate therapy strategies. Sixty-three patients took part in the threefold diagnostic approach (medical examination, psychiatric exploration, environmental analysis) of a mixed qualitative/quantitative study. Interdisciplinary case conferences allowed a consensus rating of the aetiological relevance of the findings to be reached. The discrepancy between self-rating and experts' judgement was exploited for subgroup formation. About 50% of the patients' symptoms could be attributed to psychiatric causes. Based on self-rating and experts' judgement, four subgroups were distinguished with differing medical, psychiatric and environmental aetiologies, personality traits and interactional competencies. Patients with environment-related disorders form a heterogeneous group. An interdisciplinary assessment and a comparison between self- and experts' judgements enable a more differentiated psychotherapeutic procedure and may enhance future treatment success.
Canon, Abbey J; Lauterbach, Nicholas; Bates, Jessica; Skoland, Kristin; Thomas, Paul; Ellingson, Josh; Ruston, Chelsea; Breuer, Mary; Gerardy, Kimberlee; Hershberger, Nicole; Hayman, Kristen; Buckley, Alexis; Holtkamp, Derald; Karriker, Locke
2017-06-15
OBJECTIVE To develop and evaluate a pyramid training method for teaching techniques for collection of diagnostic samples from swine. DESIGN Experimental trial. SAMPLE 45 veterinary students. PROCEDURES Participants went through a preinstruction assessment to determine their familiarity with the equipment needed and techniques used to collect samples of blood, nasal secretions, feces, and oral fluid from pigs. Participants were then shown a series of videos illustrating the correct equipment and techniques for collecting samples and were provided hands-on pyramid-based instruction wherein a single swine veterinarian trained 2 or 3 participants on each of the techniques and each of those participants, in turn, trained additional participants. Additional assessments were performed after the instruction was completed. RESULTS Following the instruction phase, percentages of participants able to collect adequate samples of blood, nasal secretions, feces, and oral fluid increased, as did scores on a written quiz assessing participants' ability to identify the correct equipment, positioning, and procedures for collection of samples. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the pyramid training method may be a feasible way to rapidly increase diagnostic sampling capacity during an emergency veterinary response to a swine disease outbreak.
Harmsen, S; Mayatepek, E; Klee, D; Meissner, T
2010-03-01
Bloody nipple discharge in adults is, in men as well as in women, often a symptom of an underlying malignant disease. In respect of this, multiple invasive and mutilating diagnostic procedures have been performed in infants and older children. Apart from individual cases in older and pubertal children, in childhood benign conditions are most common and can be diagnosed by non-invasive diagnostic procedures. Here we discuss a rational diagnostic approach on the basis of 2 patients with bloody nipple discharge at the age of 8 and 9 months which resolved spontaneously without treatment after 3 and 6 months, respectively. (c) Georg Thieme Verlag KG Stuttgart-New York.
Evaluation of a virtual-reality-based simulator using passive haptic feedback for knee arthroscopy.
Fucentese, Sandro F; Rahm, Stefan; Wieser, Karl; Spillmann, Jonas; Harders, Matthias; Koch, Peter P
2015-04-01
The aim of this work is to determine face validity and construct validity of a new virtual-reality-based simulator for diagnostic and therapeutic knee arthroscopy. The study tests a novel arthroscopic simulator based on passive haptics. Sixty-eight participants were grouped into novices, intermediates, and experts. All participants completed two exercises. In order to establish face validity, all participants filled out a questionnaire concerning different aspects of simulator realism, training capacity, and different statements using a seven-point Likert scale (range 1-7). Construct validity was tested by comparing various simulator metric values between novices and experts. Face validity could be established: overall realism was rated with a mean value of 5.5 points. Global training capacity scored a mean value of 5.9. Participants considered the simulator as useful for procedural training of diagnostic and therapeutic arthroscopy. In the foreign body removal exercise, experts were overall significantly faster in the whole procedure (6 min 24 s vs. 8 min 24 s, p < 0.001), took less time to complete the diagnostic tour (2 min 49 s vs. 3 min 32 s, p = 0.027), and had a shorter camera path length (186 vs. 246 cm, p = 0.006). The simulator achieved high scores in terms of realism. It was regarded as a useful training tool, which is also capable of differentiating between varying levels of arthroscopic experience. Nevertheless, further improvements of the simulator especially in the field of therapeutic arthroscopy are desirable. In general, the findings support that virtual-reality-based simulation using passive haptics has the potential to complement conventional training of knee arthroscopy skills. II.
Jordan, Berit; Kellner, Juliane; Jordan, Karin; Bähre, Manfred; Behrmann, Curd; Zierz, Stephan
2016-04-01
Precise diagnostic work up of a suspected thymic pathology in patients with myasthenia gravis (MG) is very important for potential surgical implications and further disease course. In this study the diagnostic value of combined preoperative radiological (CAT scan) and nuclear based imaging (octreotide and thallium scintigraphy) in patients with MG was evaluated. Twenty four patients were included. Histopathology revealed thymoma in nine patients, thymic carcinoma (TC) in one patient, lymphofollicular hyperplasia in seven patients, and involuted thymus in another seven patients. Diagnostic sensitivity for detecting thymoma/TC was 80 % in CAT scan as well as in somatostatin scintigraphy; the combination of both procedures reached 90 %. However, the diagnostic specifity to exclude thymoma in CAT scan was 100 % and in octreotide scintigraphy 85.7 %. Semiquantitative octreotide uptake significantly correlated with histological grading of thymoma/TC (r = 0.764) and histological proliferation rate Ki67 (r = 0.894). Thallium scintigraphy was positive only in one out of four thymoma cases. In this study, somatostatin scintigraphy has been shown to be a useful additional diagnostic technique in detecting thymic malignancies in patients with MG. These results might be especially helpful in patients with late onset MG as these patients are in general no candidates for thymectomy.
Monroe, Glen R; Frederix, Gerardus W; Savelberg, Sanne M C; de Vries, Tamar I; Duran, Karen J; van der Smagt, Jasper J; Terhal, Paulien A; van Hasselt, Peter M; Kroes, Hester Y; Verhoeven-Duif, Nanda M; Nijman, Isaäc J; Carbo, Ellen C; van Gassen, Koen L; Knoers, Nine V; Hövels, Anke M; van Haelst, Mieke M; Visser, Gepke; van Haaften, Gijs
2016-09-01
This study investigated whole-exome sequencing (WES) yield in a subset of intellectually disabled patients referred to our clinical diagnostic center and calculated the total costs of these patients' diagnostic trajectory in order to evaluate early WES implementation. We compared 17 patients' trio-WES yield with the retrospective costs of diagnostic procedures by comprehensively examining patient records and collecting resource use information for each patient, beginning with patient admittance and concluding with WES initiation. We calculated cost savings using scenario analyses to evaluate the costs replaced by WES when used as a first diagnostic tool. WES resulted in diagnostically useful outcomes in 29.4% of patients. The entire traditional diagnostic trajectory average cost was $16,409 per patient, substantially higher than the $3,972 trio-WES cost. WES resulted in average cost savings of $3,547 for genetic and metabolic investigations in diagnosed patients and $1,727 for genetic investigations in undiagnosed patients. The increased causal variant detection yield by WES and the relatively high costs of the entire traditional diagnostic trajectory suggest that early implementation of WES is a relevant and cost-efficient option in patient diagnostics. This information is crucial for centers considering implementation of WES and serves as input for future value-based research into diagnostics.Genet Med 18 9, 949-956.
ERIC Educational Resources Information Center
Hennings, Sara S.; Hughes, Kay E.
This paper provides a brief description of the development of the Diagnostic Assessments of Reading with Trial Teaching Strategies (DARTTS) program by F. G. Roswell and J. S. Chall. It also describes the editorial and statistical procedures that were used to validate the program for determining students' strengths and weaknesses in important areas…
Fast Beam-Based BPM Calibration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bertsche, K.; Loos, H.; Nuhn, H.-D.
2012-10-15
The Alignment Diagnostic System (ADS) of the LCLS undulator system indicates that the 33 undulator quadrupoles have extremely high position stability over many weeks. However, beam trajectory straightness and lasing efficiency degrade more quickly than this. A lengthy Beam Based Alignment (BBA) procedure must be executed every two to four weeks to re-optimize the X-ray beam parameters. The undulator system includes RF cavity Beam Position Monitors (RFBPMs), several of which are utilized by an automatic feedback system to align the incoming electron-beam trajectory to the undulator axis. The beam trajectory straightness degradation has been traced to electronic drifts of themore » gain and offset of the BPMs used in the beam feedback system. To quickly recover the trajectory straightness, we have developed a fast beam-based procedure to recalibrate the BPMs. This procedure takes advantage of the high-precision monitoring capability of the ADS, which allows highly repeatable positioning of undulator quadrupoles. This report describes the ADS, the position stability of the LCLS undulator quadrupoles, and some results of the new recovery procedure.« less
Patterson, Olga V; Forbush, Tyler B; Saini, Sameer D; Moser, Stephanie E; DuVall, Scott L
2015-01-01
In order to measure the level of utilization of colonoscopy procedures, identifying the primary indication for the procedure is required. Colonoscopies may be utilized not only for screening, but also for diagnostic or therapeutic purposes. To determine whether a colonoscopy was performed for screening, we created a natural language processing system to identify colonoscopy reports in the electronic medical record system and extract indications for the procedure. A rule-based model and three machine-learning models were created using 2,000 manually annotated clinical notes of patients cared for in the Department of Veterans Affairs. Performance of the models was measured and compared. Analysis of the models on a test set of 1,000 documents indicates that the rule-based system performance stays fairly constant as evaluated on training and testing sets. However, the machine learning model without feature selection showed significant decrease in performance. Therefore, rule-based classification system appears to be more robust than a machine-learning system in cases when no feature selection is performed.
Diagnostic articulation tables
NASA Astrophysics Data System (ADS)
Mikhailov, V. G.
2002-09-01
In recent years, considerable progress has been made in the development of instrumental methods for general speech quality and intelligibility evaluation on the basis of modeling the auditory perception of speech and measuring the signal-to-noise ratio. Despite certain advantages (fast measurement procedures with a low labor consumption), these methods are not universal and, in essence, secondary, because they rely on the calibration based on subjective-statistical measurements. At the same time, some specific problems of speech quality evaluation, such as the diagnostics of the factors responsible for the deviation of the speech quality from standard (e.g., accent features of a speaker or individual voice distortions), can be solved by psycholinguistic methods. This paper considers different kinds of diagnostic articulation tables: tables of minimal pairs of monosyllabic words (DRT) based on the Jacobson differential features, tables consisting of multisyllabic quartets of Russian words (the choice method), and tables of incomplete monosyllables of the _VC/CV_ type (the supplementary note method). Comparative estimates of the tables are presented along with the recommendations concerning their application.
The role of invasive and non-invasive procedures in diagnosing fever of unknown origin.
Mete, Bilgul; Vanli, Ersin; Yemisen, Mucahit; Balkan, Ilker Inanc; Dagtekin, Hilal; Ozaras, Resat; Saltoglu, Nese; Mert, Ali; Ozturk, Recep; Tabak, Fehmi
2012-01-01
The etiology of fever of unknown origin has changed because of the recent advances in and widespread use of invasive and non-invasive diagnostic tools. However, undiagnosed patients still constitute a significant number. To determine the etiological distribution and role of non-invasive and invasive diagnostic tools in the diagnosis of fever of unknown origin. One hundred patients who were hospitalized between June 2001 and 2009 with a fever of unknown origin were included in this study. Clinical and laboratory data were collected from the patients' medical records retrospectively. Fifty three percent of the patients were male, with a mean age of 45 years. The etiology of fever was determined to be infectious diseases in 26, collagen vascular diseases in 38, neoplastic diseases in 14, miscellaneous in 2 and undiagnosed in 20 patients. When the etiologic distribution was analyzed over time, it was noted that the rate of infectious diseases decreased, whereas the rate of rheumatological and undiagnosed diseases relatively increased because of the advances in imaging and microbiological studies. Seventy patients had a definitive diagnosis, whereas 10 patients had a possible diagnosis. The diagnoses were established based on clinical features and non-invasive tests for 61% of the patients and diagnostic benefit was obtained for 49% of the patients undergoing invasive tests. Biopsy procedures contributed a rate of 42% to diagnoses in patients who received biopsies. Clinical features (such as detailed medical history-taking and physical examination) may contribute to diagnoses, particularly in cases of collagen vascular diseases. Imaging studies exhibit certain pathologies that guide invasive studies. Biopsy procedures contribute greatly to diagnoses, particularly for malignancies and infectious diseases that are not diagnosed by non-invasive procedures.
Arias, Sixto; Lee, Hans; Semaan, Roy; Frimpong, Bernice; Ortiz, Ricardo; Feller-Kopman, David; Oakjones-Burgess, Karen; Yarmus, Lonny
2015-05-23
Lung nodule evaluation represents a clinical challenge especially in patients with intermediate risk for malignancy. Multiple technologies are presently available to sample nodules for pathological diagnosis. Those technologies can be divided into bronchoscopic and non-bronchoscopic interventions. Electromagnetic navigational bronchoscopy is being extensively used for the endobronchial approach to peripheral lung nodules but has been hindered by anatomic challenges resulting in a 70% diagnostic yield. Electromagnetic navigational guided transthoracic needle lung biopsy is novel non-bronchoscopic method that uses a percutaneous electromagnetic tip tracked needle to obtain core biopsy specimens. Electromagnetic navigational transthoracic needle aspiration complements bronchoscopic techniques potentially allowing the provider to maximize the diagnostic yield during one single procedure. This article describes a novel integrated diagnostic approach to pulmonary lung nodules. We propose the use of endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) for mediastinal staging; radial EBUS, navigational bronchoscopy and E-TTNA during one single procedure to maximize diagnostic yield and minimize the number of invasive procedures needed to obtain a diagnosis. This manuscript describes in detail how the navigation transthoracic procedure is performed. Additional clinical studies are needed to determine the clinical utility of this novel technology.
Experience with diagnostic laparoscopy for gynecological indications.
Ikechebelu, J I
2013-01-01
Diagnostic laparoscopy is an endoscopy procedure, which has become indispensable in the evaluation of the female reproductive organs especially in infertility. Experience with conversion to open laparotomy is presented and ways of averting this complication are discussed. A retrospective study was performed. All the 1654 diagnostic laparoscopies performed at a private fertility center over a 10-year period (January 2000 to December 2009) were analyzed for indications, cases of conversion to open laparotomy, and measures taken to prevent this complication. Simple percentage method was used. Infertility was the commonest indication for 1627 (98.4%) procedures, while primary amenorrhoea and chronic pelvic pain were responsible for 20 (1.2%) and 7 (0.4%) procedures, respectively. There was no mortality in this series. There was conversion to open laparotomy due to hemorrhage in only 2 (0.12%) procedures and this happened at the first year of practice. The low rate of conversion was attributed to the surgeons experience, proper patient selection, and the use of Palmers point for insufflation in some patients with previous pelvic surgeries and use of supraumbilical access in patients with pelvic masses. Diagnostic laparoscopy for gynecological indications is safe and wider application of this modern technology is recommended for our practice.
Maliye, Sylvia; Marshall, John F
2016-10-15
OBJECTIVE To characterize and describe the compensatory load redistribution that results from unilateral hind limb lameness in horses. DESIGN Retrospective case series. ANIMALS 37 client-owned horses. PROCEDURES Medical records were reviewed to identify horses with unilateral hind limb lameness that responded positively (by objective assessment) to diagnostic local anesthesia during lameness evaluation and that were evaluated before and after diagnostic local anesthesia with an inertial sensor-based lameness diagnosis system. Horses were grouped as having hind limb lameness only, hind limb and ipsilateral forelimb lameness, or hind limb and contralateral forelimb lameness. Measures of head and pelvic movement asymmetry before (baseline) and after diagnostic local anesthesia were compared. The effect of group on baseline pelvic movement asymmetry variables was analyzed statistically. RESULTS Maximum pelvic height significantly decreased from the baseline value after diagnostic local anesthesia in each of the 3 lameness groups and in all horses combined. Minimum pelvic height significantly decreased after the procedure in all groups except the hind limb and contralateral forelimb lameness group. Head movement asymmetry was significantly decreased after diagnostic local anesthesia for horses with hind limb and ipsilateral forelimb lameness and for all horses combined, but not for those with hind limb lameness only or those with hind limb and contralateral forelimb lameness. CONCLUSIONS AND CLINICAL RELEVANCE Results supported that hind limb lameness can cause compensatory load redistribution evidenced as ipsilateral forelimb lameness. In this population of horses, contralateral forelimb lameness was not compensatory and likely reflected true lameness. Further studies are needed to investigate the source of the contralateral forelimb lameness in such horses.
DOT National Transportation Integrated Search
1982-04-01
A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...
[A new information technology for system diagnosis of functional activity of human organs].
Avshalumov, A Sh; Sudakov, K V; Filaretov, G F
2006-01-01
The goal of this work was to consider a new diagnostic technology based on analysis of objective information parameters of functional activity and interaction of normal and pathologically changed human organs. The technology is based on the use of very low power millimeter (EHF) radiation emitted by human body and other biological objects in the process of vital activity. The importance of consideration of the information aspect of vital activity from the standpoint of the theory of functional systems suggested by P. K. Anokhin is emphasized. The suggested information technology is theoretically substantiated. The capabilities of the suggested technology for diagnosis, as well as the difficulties of its practical implementation caused by very low power of electromagnetic fields generated by human body, are discussed. It is noted that only use of modern radiophysical equipment together with new software based on specially developed algorithms made it possible to construct a medical EHF diagnostic system for effective implementation of the suggested technology. The system structure, functions of its components, the examination procedure, and the form of representation of diagnostic information are described together with the specific features of applied software based on the principle of maximal objectivity of analysis and interpretation of the results of diagnosis on the basis of artificial intelligence algorithms. The diagnostic capabilities of the system are illustrated by several examples.
Michaud, Ginette Y
2005-01-01
In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.
Present status of endoscopy, therapeutic endoscopy and the endoscopy training system in Indonesia.
Makmun, Dadang
2014-04-01
Recently, Indonesia was ranked as the fourth most populous country in the world. Based on 2012 data, 85000 general practitioners and 25000 specialists are in service around the country. Gastrointestinal (GI) disease remains the most common finding in daily practise, in both outpatient and inpatient settings, and ranks fifth in causing mortality in Indonesia. Management of patients with GI disease involves all health-care levels with the main portion in primary health care. Some are managed by specialists in secondary health care or are referred to tertiary health care. GI endoscopy is one of the main diagnostic and therapeutic modalities in the management of GI disease. Development of GI endoscopy in Indonesia started before World War II and, today, many GI endoscopy procedures are conducted in Indonesia, both diagnostic and therapeutic. Based on August 2013 data, there are 515 GI endoscopists in Indonesia. Most GI endoscopists are competent in carrying out basic endoscopy procedures, whereas only a few carry out advanced endoscopy procedures, including therapeutic endoscopy. Recently, the GI endoscopy training system in Indonesia consists of basic GI endoscopy training of 3-6 months held at 10 GI endoscopy training centers. GI endoscopy training is also eligible as part of a fellowship program of consultant gastroenterologists held at six accredited fellowship centers in Indonesia. Indonesian Society for Digestive Endoscopy in collaboration with GI endoscopy training centers in Indonesia and overseas has been working to increase quality and number of GI endoscopists, covering both basic and advanced GI endoscopy procedures. © 2014 The Author. Digestive Endoscopy © 2014 Japan Gastroenterological Endoscopy Society.
Rose, Michael; Curtze, Carolin; O'Sullivan, Joseph; El-Gohary, Mahmoud; Crawford, Dennis; Friess, Darin; Brady, Jacqueline M
2017-12-01
To develop a model using wearable inertial sensors to assess the performance of orthopaedic residents while performing a diagnostic knee arthroscopy. Fourteen subjects performed a diagnostic arthroscopy on a cadaveric right knee. Participants were divided into novices (5 postgraduate year 3 residents), intermediates (5 postgraduate year 4 residents), and experts (4 faculty) based on experience. Arm movement data were collected by inertial measurement units (Opal sensors) by securing 2 sensors to each upper extremity (dorsal forearm and lateral arm) and 2 sensors to the trunk (sternum and lumbar spine). Kinematics of the elbow and shoulder joints were calculated from the inertial data by biomechanical modeling based on a sequence of links connected by joints. Range of motion required to complete the procedure was calculated for each group. Histograms were used to compare the distribution of joint positions for an expert, intermediate, and novice. For both the right and left upper extremities, skill level corresponded well with shoulder abduction-adduction and elbow prono-supination. Novices required on average 17.2° more motion in the right shoulder abduction-adduction plane than experts to complete the diagnostic arthroscopy (P = .03). For right elbow prono-supination (probe hand), novices required on average 23.7° more motion than experts to complete the procedure (P = .03). Histogram data showed novices had markedly more variability in shoulder abduction-adduction and elbow prono-supination compared with the other groups. Our data show wearable inertial sensors can measure joint kinematics during diagnostic knee arthroscopy. Range-of-motion data in the shoulder and elbow correlated inversely with arthroscopic experience. Motion pattern-based analysis shows promise as a metric of resident skill acquisition and development in arthroscopy. Wearable inertial sensors show promise as metrics of arthroscopic skill acquisition among residents. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Gallot, D; Vélémir, L; Delabaere, A; Accoceberry, M; Niro, J; Vendittelli, F; Laurichesse-Delmas, H; Jacquetin, B; Lémery, D
2009-12-01
To describe invasive diagnostic procedures (amniocentesis/choriocentesis) and subsequent risks in twin pregnancies. PubMed and Cochrane database investigations were conducted using following key words: twin gestation, amniocentesis, chorionic villous sampling, karyotype. Guidelines for twin management edicted by different societies were reviewed. Risk of pregnancy loss after invasive diagnostic procedure in twin pregnancies seems to be slightly higher to singletons, i.e about 1.5-2% after mid-trimester amniocentesis and about 2% after first trimester choriocentesis. Dual sampling is not always mandatory but can be performed on parent's request. Specific risks are associated with twins: redundant sampling, permutation or misidentification of affected twin in case of discordant status. Procedures should be performed by highly-skilled operators under permanent ultrasound-guidance. A scheme describing placental locations and funicular insertions appears to be useful for correct identification. If foeticide can be anticipated, diagnostic procedure and foeticide should be performed by the same operators. For amniocentesis, one or two needles can be used except for cases with infectious disease (two needles and two separate insertions required). For choriocentesis, sampling should be performed close to funicular insertions. First-trimester choriocentesis makes earlier diagnosis and earlier foeticide possible compared with mid-trimester amniocentesis. Both techniques require highly-skilled operators to reduce subsequent risks in the context of twin pregnancies. Copyright © 2009 Elsevier Masson SAS. All rights reserved.
The procedure for isolation of neoplasms on the retina of the eye
NASA Astrophysics Data System (ADS)
Komkova, S. V.
2018-01-01
In operation, a computer diagnostic procedure on the human retina neoplasms. The use of this technique in medical institutions in the operation of the ophthalmic practitioner allows earlv detection of the disease, at periodic inspection of a pictorial pattern of disease progression. The test procedure is performed on a set of real human retinal photographs taken from international STARE database with known diagnoses. Given the numerous experiments which show the possibility of using this technique, developed on the basis of the diagnostic system in a doctor’s office-ophthalmic.
Boettcher, Johanna; Berger, Thomas; Renneberg, Babette
2012-10-01
Numerous studies suggest that Internet-based self-help treatments are effective in treating anxiety disorders. Trials evaluating such interventions differ in their screening procedures and in the amount of clinician contact in the diagnostic assessment phase. The present study evaluates the impact of a pre-treatment diagnostic interview on the outcome of an Internet-based treatment for Social Anxiety Disorder (SAD). One hundred and nine participants seeking treatment for SAD were randomized to either an interview-group (IG, N = 53) or to a non-interview group (NIG, N = 56). All participants took part in the same 10-week cognitive-behavioural unguided self-help programme. Before receiving access to the programme, participants of the IG underwent a structured diagnostic interview. Participants of the NIG started directly with the programme. Participants in both groups showed significant and substantial improvement on social anxiety measures from pre- to post-assessment (d IG = 1.30-1.63; d NIG = 1.00-1.28) and from pre- to 4-month follow-up assessment (d IG = 1.38-1.87; d NIG = 1.10-1.21). Significant between-groups effects in favour of the IG were found on secondary outcome measures of depression and general distress (d = 0.18-0.42). These findings suggest that Internet-based self-help is effective in treating SAD, whether or not a diagnostic interview is involved. However, the pre-treatment interview seems to facilitate change on secondary outcomes such as depression and general distress.
Optimal Spectral Regions For Laser Excited Fluorescence Diagnostics For Point Of Care Application
NASA Astrophysics Data System (ADS)
Vaitkuviene, A.; Gėgžna, V.; Varanius, D.; Vaitkus, J.
2011-09-01
The tissue fluorescence gives the response of light emitting molecule signature, and characterizes the cell composition and peculiarities of metabolism. Both are useful for the biomedical diagnostics, as reported in previous our and others works. The present work demonstrates the results of application of laser excited autofluorescence for diagnostics of pathology in genital tissues, and the feasibility for the bedside at "point of care—off lab" application. A portable device using the USB spectrophotometer, micro laser (355 nm Nd:YAG, 0,5 ns pulse, repetition rate 10 kHz, output power 15 mW), three channel optical fiber and computer with diagnostic program was designed and ready for clinical trial to be used for cytology and biopsy specimen on site diagnostics, and for the endoscopy/puncture procedures. The biopsy and cytology samples, as well as intervertebral disc specimen were evaluated by pathology experts and the fluorescence spectra were investigated in the fresh and preserved specimens. The spectra were recorded in the spectral range 350-900 nm. At the initial stage the Gaussian components of spectra were found and the Mann-Whitney test was used for the groups' differentiation and the spectral regions for optimal diagnostics purpose were found. Then a formal dividing of spectra in the components or the definite width bands, where the main difference of the different group spectra was observed, was used to compare these groups. The ROC analysis based diagnostic algorithms were created for medical prognosis. The positive prognostic values and negative prediction values were determined for cervical Liquid PAP smear supernatant sediment diagnosis of being Cervicitis and Norma versus CIN2+. In a case of intervertebral disc the analysis allows to get the additional information about the disc degeneration status. All these results demonstrated an efficiency of the proposed procedure and the designed device could be tested at the point-of-care site or for intervertebral disc operations.
Diagnostic strategies for urinary tract infections in French general practice.
Kinouani, S; de Lary de Latour, H; Joseph, J-P; Letrilliart, L
2017-10-01
We aimed to describe the diagnostic management procedures for detection of urinary tract infections in general practice and their correlated factors. We analyzed data from the ECOGEN study on urinary tract infections, collected in France between November 2011 and April 2012. This national cross-sectional study was carried out in general practices. Data was coded according to the International Classification of Primary Care. A total of 340 consultations or home visits were held for urinary tract infections. The five most frequent diagnostic procedures were (in descending order) clinical examination (67.6%), urine cytobacteriological examination (UCBE) (47.9%), urine dipstick test (15.6%), blood test (8.5%), and imaging (6.5%). No urine dipstick test or UCBE was performed in 43% of cases. Factors correlated with diagnostic procedures were age and gender of patients, annual number of consultations held by family physicians, and duration of consultation. Family physicians did not comply with guidelines on diagnostic management for detection of urinary tract infections. We hypothesized that this non-compliance could be due to the family physicians' environment and characteristics, and to clinical practice guidelines. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Weber, Alexander E; Zuke, William; Mayer, Erik N; Forsythe, Brian; Getgood, Alan; Verma, Nikhil N; Bach, Bernard R; Bedi, Asheesh; Cole, Brian J
2018-02-01
There has been an increasing interest in lateral-based soft tissue reconstructive techniques as augments to anterior cruciate ligament reconstruction (ACLR). The objective of these procedures is to minimize anterolateral rotational instability of the knee after surgery. Despite the relatively rapid increase in surgical application of these techniques, many clinical questions remain. To provide a comprehensive update on the current state of these lateral-based augmentation procedures by reviewing the origins of the surgical techniques, the biomechanical data to support their use, and the clinical results to date. Systematic review. A systematic search of the literature was conducted via the Medline, EMBASE, Scopus, SportDiscus, and CINAHL databases. The search was designed to encompass the literature on lateral extra-articular tenodesis (LET) procedures and the anterolateral ligament (ALL) reconstruction. Titles and abstracts were reviewed for relevance and sorted into the following categories: anatomy, biomechanics, imaging/diagnostics, surgical techniques, and clinical outcomes. The search identified 4016 articles. After review for relevance, 31, 53, 27, 35, 45, and 78 articles described the anatomy, biomechanics, imaging/diagnostics, surgical techniques, and clinical outcomes of either LET procedures or the ALL reconstruction, respectively. A multitude of investigations were available, revealing controversy in addition to consensus in several categories. The level of evidence obtained from this search was not adequate for systematic review or meta-analysis; thus, a current concepts review of the anatomy, biomechanics, imaging, surgical techniques, and clinical outcomes was performed. Histologically, the ALL appears to be a distinct structure that can be identified with advanced imaging techniques. Biomechanical evidence suggests that the anterolateral structures of the knee, including the ALL, contribute to minimizing anterolateral rotational instability. Cadaveric studies of combined ACLR-LET procedures demonstrated overconstraint of the knee; however, these findings have yet to be reproduced in the clinical literature. The current indications for LET augmentation in the setting of ACLR and the effect on knee kinematic and joint preservation should be the subject of future research.
Lundin, Johan; Dumont, Guy
2017-01-01
ABSTRACT Current advances within medical technology show great potential from a global health perspective. Inexpensive, effective solutions to common problems within diagnostics, medical procedures and access to medical information are emerging within almost all fields of medicine. The innovations can benefit health care both in resource-limited and in resource-rich settings. However, there is a big gap between the proof-of-concept stage and implementation. This article will give examples of promising solutions, with special focus on mobile image- and sensor-based diagnostics. We also discuss how technology and frugal innovations could be made sustainable and widely available. Finally, a list of critical factors for success is presented, based on both our own experiences and the literature. PMID:28838308
Spiritoso, Stephen; Gross, Erin; Bean, Canise Y; Casamassimo, Paul S; Levings, Kevin; Lloyd, Patrick
2015-08-01
The aim of this study was to investigate the contribution of a tiered predoctoral pediatric dentistry clinical education model to competency achievement by dental students over a two-year clinical education. Retrospective data were obtained for academic years 2012-13 and 2013-14 from three sources: a campus-based, dental school-housed clinic; division-directed clinics in community-based pediatric and special needs clinics (DDC); and clinics affiliated with the dental college's community-based dental education (CBDE) program, the OHIO Project (OP). A fourth dataset was obtained for the same two-year period from a biannual clinic event held at the college in conjunction with Give Kids a Smile Day (GKAS). Procedures considered essential to the care of children were sorted by 12 dental codes from all services for patients 18 years of age and younger. The dental school clinic provided 11,060 procedures; the DDC, 28,462; the OP, 17,863; and GKAS, 2,028. The two-year total was 59,433 procedures. Numbers of diagnostic and preventive procedures were 19,441, restorative procedures were 13,958, and pulp and surgical procedures were 7,392. Site contribution ranged from 52.2 to 144.9 procedures per attending student, with the DDC yielding the highest per student average for each year (126.4 and 144.9) and the dental school clinic the lowest (52.2 and 53.1). This study found that a combination of school-based, community-based, and philanthropic pediatric dental experiences offered a large number of essential pediatric dentistry experiences for predoctoral dental students, with CBDE opportunities offering the largest contribution.
Engelke, W; Mommaerts, M
1990-04-01
There is no doubt that double-contrast TMJ fluoroscopic tomography enables a differential diagnosis and treatment in internal derangement pathosis. Its indication is, apart from the expected diagnostic gain, also determined by the degree of its invasiveness, and other alternative diagnostics being available (nuclear magnetic resonance). Data on patient discomfort and complications were gathered in 63 arthrotomographies; pain sensations and mandibular mobility, during and after the procedure in particular, were studied. We consider, along with Westesson, the procedure to be less invasive than commonly considered, once the surgeon-radiologist has gained enough experience.
Cohen, Micah G; McMahon, Colm J; Kung, Justin W; Wu, Jim S
2016-05-01
The purpose of this study was to compare manual and battery-powered bone biopsy systems for diagnostic yield and procedural factors during core needle biopsy of sclerotic bone lesions. A total of 155 consecutive CT-guided core needle biopsies of sclerotic bone lesions were performed at one institution from January 2006 to November 2014. Before March 2012, lesions were biopsied with manual bone drill systems. After March 2012, most biopsies were performed with a battery-powered system and either noncoaxial or coaxial biopsy needles. Diagnostic yield, crush artifact, CT procedure time, procedure radiation dose, conscious sedation dose, and complications were compared between the manual and battery-powered core needle biopsy systems by Fisher exact test and t test. One-way ANOVA was used for subgroup analysis of the two battery-powered systems for procedure time and radiation dose. The diagnostic yield for all sclerotic lesions was 60.0% (93/155) and was significantly higher with the battery-powered system (73.0% [27/37]) than with the manual systems (55.9% [66/118]) (p = 0.047). There was no significant difference between the two systems in terms of crush artifact, procedure time, radiation dose, conscious sedation administered, or complications. In subgroup analysis, the coaxial battery-powered biopsies had shorter procedure times (p = 0.01) and lower radiation doses (p = 0.002) than the coaxial manual systems, but the noncoaxial battery-powered biopsies had longer average procedure times and higher radiation doses than the coaxial manual systems. In biopsy of sclerotic bone lesions, use of a battery-powered bone drill system improves diagnostic yield over use of a manual system.
Luparia, A; Durando, M; Campanino, P; Regini, E; Lucarelli, D; Talenti, A; Mattone, G; Mariscotti, G; Sapino, A; Gandini, G
2011-04-01
The authors sought to evaluate the diagnostic accuracy and cost-effectiveness of vacuum-assisted core biopsy (VACB) in comparison with diagnostic surgical excision for characterisation of nonpalpable breast lesions classified as Breast Imaging Reporting and Data System (BI-RADS) categories R3 and R4. From January 2004 to December 2008, we conducted 602 stereotactic, 11-gauge, VACB procedures on 243 nonpalpable breast lesions categorised as BI-RADS R3, 346 categorised as BI-RADS R4 and 13 categorised as BI-RADS R5. We calculated the diagnostic accuracy and cost savings of VACB by subtracting the cost of the stereotactic biopsy from that of the diagnostic surgical procedure. A total of 56% of the lesions were benign and required no further assessment. Lesions of uncertain malignant potential (B3) (23.6%) were debated at multidisciplinary meetings, and diagnostic surgical biopsy was recommended for 83.1% of them. All malignant lesions (B4 and B5) underwent surgical excision. VACB had a sensitivity of 94.9%, specificity of 98.3% and diagnostic accuracy of 97.7%. The cost savings per VACB procedure were 464.00 euro; by obviating 335 surgical biopsies, the overall cost savings was 155,440.00 euro over 5 years. VACB proved to have high diagnostic accuracy for characterising abnormalities at low to intermediate risk of malignancy and obviated surgical excision in about half of the cases, allowing for considerable cost savings.
A description of the content of army family practice.
Blount, B W; Hart, G; Ehreth, J L
1993-01-01
For decisions about residency curricula and downsizing the US Army medical corps, decision makers must know the practice content of the various specialties. Little is known about the content of Army family practice. The purpose of our study was to describe the content of Army family practice. We analyzed a random sample of 28,849 family practice encounters from the US Army Ambulatory Care Data Base Study. Variables included patient demographics, diagnoses, visit duration, procedures, and medical facility. Patient age and visit duration were compared using analysis of variance; facility profiles were compared by age category and sex of patients, family member position, and procedure frequency using chi-square analysis. Diagnostic content of the facilities was compared by both chi-square and Kendall's tau B tests. The typical patient was a 26-year-old woman. The 25 most frequent diagnoses accounted for three-fourths of all encounters, with variation by patient age. The majority of visits did not include a procedure, but procedure frequency varied by patient age and diagnostic certainty. Mean visit duration was 16.4 minutes and varied by age. There were differences among the sites for all variables. Army family physicians see patients of all ages, of whom more are the family members of soldiers than the soldiers themselves; they frequently do procedures and are usually certain of their diagnoses, which include a broad spectrum of illnesses. Army family physicians are flexible, adapt to local patient and environmental needs, and are uniquely qualified to form the basis of Army medicine.
Ambulatory Care Data Base (ACDB) Data Dictionary Sequential Files of Phase 2.
1992-04-01
CEREBRAL ARTERIES 4340 CEREBRAL THROMBOSIS 43491 STROKE , ISCHEMIC 435 TRANSIENT CEREBRAL ISCHEMIA 4359 TRANSIENT ISCHEMIC ATTACK (TIA) 43591 TRANS...HYPERTENSIVE CRISIS 4373 ANEURYSM, CEREBRAL , NONRUPTURED 4374 ARTERITIS, CEREBRAL 4378 CEREBROVASCULAR DISEASE, OTHER ILL-DEFINED 43781 STROKE , LACUNAR...95950 MONITORING FOR LOCALIZATION OF CEREBRAL SEIZURE FOC 95999 OTHER NEUROLOGICAL DIAGNOSTIC PROCEDURES 96500 CHEMO INJ, SINGLE, PRE-MIX, PUSH 96501
ERIC Educational Resources Information Center
Lancioni, Giulio E.; Singh, Nirbhay N.; O'Reilly, Mark F.; Sigafoos, Jeff; Buonocunto, Francesca; Sacco, Valentina; Colonna, Fabio; Navarro, Jorge; Lanzilotti, Crocifissa; Bosco, Andrea; Megna, Gianfranco; De Tommaso, Marina
2009-01-01
Post-coma persons in an apparent condition of vegetative state and pervasive motor impairment pose serious problems in terms of assessment and intervention options. A technology-based learning assessment procedure might serve for them as a diagnostic supplement with possible implications for rehabilitation intervention. The learning assessment…
Wales, Michele; Cartier, Eddie
2015-01-01
One of the reasons that the United States is a leader in biotechnology is its strong and reliable patent system. However, the Supreme Court’s decision in Myriad potentially limits an inventor’s ability to protect her DNA-based inventions. Fortunately, with creativity, there are numerous ways in which to “claim around” Myriad, enabling inventors to fully protect their diagnostic or therapeutic inventions. Thus, under a proper reading of the holding, the potential negative effect of Myriad on the progress of biotechnology would be negligible. Unfortunately, the U.S. Patent and Trademark Office has promulgated revised examination procedures in the wake of Myriad that have the potential to greatly limit the patentability of all inventions based on products found in nature and create uncertainty that will not be resolved in the near future. PMID:26337114
Circulating tumor DNA: a promising biomarker in the liquid biopsy of cancer.
Cheng, Feifei; Su, Li; Qian, Cheng
2016-07-26
Tissue biopsy is the standard diagnostic procedure for cancers and also provides a material for genotyping, which can assist in the targeted therapies of cancers. However, tissue biopsy-based cancer diagnostic procedures have limitations in their assessment of cancer development, prognosis and genotyping, due to tumor heterogeneity and evolution. Circulating tumor DNA (ctDNA) is single- or double-stranded DNA released by the tumor cells into the blood and it thus harbors the mutations of the original tumor. In recent years, liquid biopsy based on ctDNA analysis has shed a new light on the molecular diagnosis and monitoring of cancer. Studies found that the screening of genetic mutations using ctDNA is highly sensitive and specific, suggesting that ctDNA analysis may significantly improve current systems of tumor diagnosis, even facilitating early-stage detection. Moreover, ctDNA analysis is capable of accurately determining the tumor progression, prognosis and assisting in targeted therapy. Therefore, using ctDNA as a liquid biopsy may herald a revolution for tumor management. Herein, we review the biology of ctDNA, its detection methods and potential applications in tumor diagnosis, treatment and prognosis.
Circulating tumor DNA: a promising biomarker in the liquid biopsy of cancer
Cheng, Feifei; Su, Li; Qian, Cheng
2016-01-01
Tissue biopsy is the standard diagnostic procedure for cancers and also provides a material for genotyping, which can assist in the targeted therapies of cancers. However, tissue biopsy-based cancer diagnostic procedures have limitations in their assessment of cancer development, prognosis and genotyping, due to tumor heterogeneity and evolution. Circulating tumor DNA (ctDNA) is single- or double-stranded DNA released by the tumor cells into the blood and it thus harbors the mutations of the original tumor. In recent years, liquid biopsy based on ctDNA analysis has shed a new light on the molecular diagnosis and monitoring of cancer. Studies found that the screening of genetic mutations using ctDNA is highly sensitive and specific, suggesting that ctDNA analysis may significantly improve current systems of tumor diagnosis, even facilitating early-stage detection. Moreover, ctDNA analysis is capable of accurately determining the tumor progression, prognosis and assisting in targeted therapy. Therefore, using ctDNA as a liquid biopsy may herald a revolution for tumor management. Herein, we review the biology of ctDNA, its detection methods and potential applications in tumor diagnosis, treatment and prognosis. PMID:27223063
The microcomputer in the dental office: a new diagnostic aid.
van der Stelt, P F
1985-06-01
The first computer applications in the dental office were based upon standard accountancy procedures. Recently, more and more computer applications have become available to meet the specific requirements of dental practice. This implies not only business procedures, but also facilities to store patient records in the system and retrieve them easily. Another development concerns the automatic calculation of diagnostic data such as those provided in cephalometric analysis. Furthermore, growth and surgical results in the craniofacial area can be predicted by computerized extrapolation. Computers have been useful in obtaining the patient's anamnestic data objectively and for the making of decisions based on such data. Computer-aided instruction systems have been developed for undergraduate students to bridge the gap between textbook and patient interaction without the risks inherent in the latter. Radiology will undergo substantial changes as a result of the application of electronic imaging devices instead of the conventional radiographic films. Computer-assisted electronic imaging will enable image processing, image enhancement, pattern recognition and data transmission for consultation and storage purposes. Image processing techniques will increase image quality whilst still allowing low-dose systems. Standardization of software and system configuration and the development of 'user friendly' programs is the major concern for the near future.
Validation of Living Donor Nephrectomy Codes
Lam, Ngan N.; Lentine, Krista L.; Klarenbach, Scott; Sood, Manish M.; Kuwornu, Paul J.; Naylor, Kyla L.; Knoll, Gregory A.; Kim, S. Joseph; Young, Ann; Garg, Amit X.
2018-01-01
Background: Use of administrative data for outcomes assessment in living kidney donors is increasing given the rarity of complications and challenges with loss to follow-up. Objective: To assess the validity of living donor nephrectomy in health care administrative databases compared with the reference standard of manual chart review. Design: Retrospective cohort study. Setting: 5 major transplant centers in Ontario, Canada. Patients: Living kidney donors between 2003 and 2010. Measurements: Sensitivity and positive predictive value (PPV). Methods: Using administrative databases, we conducted a retrospective study to determine the validity of diagnostic and procedural codes for living donor nephrectomies. The reference standard was living donor nephrectomies identified through the province’s tissue and organ procurement agency, with verification by manual chart review. Operating characteristics (sensitivity and PPV) of various algorithms using diagnostic, procedural, and physician billing codes were calculated. Results: During the study period, there were a total of 1199 living donor nephrectomies. Overall, the best algorithm for identifying living kidney donors was the presence of 1 diagnostic code for kidney donor (ICD-10 Z52.4) and 1 procedural code for kidney procurement/excision (1PC58, 1PC89, 1PC91). Compared with the reference standard, this algorithm had a sensitivity of 97% and a PPV of 90%. The diagnostic and procedural codes performed better than the physician billing codes (sensitivity 60%, PPV 78%). Limitations: The donor chart review and validation study was performed in Ontario and may not be generalizable to other regions. Conclusions: An algorithm consisting of 1 diagnostic and 1 procedural code can be reliably used to conduct health services research that requires the accurate determination of living kidney donors at the population level. PMID:29662679
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Inamdar, Sumant; Slattery, Eoin; Sejpal, Divyesh V; Miller, Larry S; Pleskow, Douglas K; Berzin, Tyler M; Trindade, Arvind J
2015-07-01
Surgically altered pancreaticobiliary anatomy increases the difficulty of performing ERCP. Single-balloon enteroscopy (SBE) is a relatively new technique that can be used for ERCP in patients with surgically altered anatomy. To evaluate the therapeutic and diagnostic success of SBE-ERCP among patients with surgically altered anatomy. Systematic review and meta-analysis of studies involving SBE-ERCP in patients with Roux-en-Y gastric bypass, hepaticojejunostomy, or Whipple procedure. Enteroscopy success was defined as success in reaching the papilla and/or biliary anastomosis by using SBE. Diagnostic success was defined as obtaining a cholangiogram. Procedural success was defined as the ability to provide successful intervention, if appropriate. A random-effects model was used. A total of 461 patients underwent SBE-ERCP from 15 trials. The pooled enteroscopy, diagnostic, and procedural success rates were 80.9% (95% confidence interval [CI], 75.3%-86.4%), 69.4% (95% CI, 61.0%-77.9%), and 61.7% (95% CI, 52.9%-70.5%), respectively. There was statistical large heterogeneity for enteroscopy, diagnostic, and therapeutic success (P < .001 for all). Adverse events occurred in 6.5% (95% CI, 4.7%-9.1%) of patients. There was no evidence of publication bias in this meta-analysis. Our findings and interpretations are limited by the quantity and heterogeneity of the studies included in the analysis. SBE-ERCP has high diagnostic and procedural success rates in this challenging patient population. It should be considered a first-line intervention when biliary access is required after Roux-en-Y gastric bypass, hepaticojejunostomy, or Whipple procedure. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Burzotta, Francesco; Brancati, Marta Francesca; Porto, Italo; Saffioti, Silvia; Aurigemma, Cristina; Niccoli, Giampaolo; Leone, Antonio Maria; Coluccia, Valentina; Crea, Filippo; Trani, Carlo
2015-12-01
Transradial approach (TRA), when compared with transfemoral, improves the safety of percutaneous coronary procedures. Arterial axis variants are known to hinder the performance of transradial approach percutaneous coronary procedures. Data on the occurrence of arterial axis variants in the right and left arm arterial axes of individual patients are lacking. From a single-center prospective registry, we selected all patients in whom bilateral upper limb arterial anatomy was assessed based on the performance of left and right radial catheterization obtained during the same or during repeat coronary diagnostic or interventional procedure(s). The occurrence of upper right and left limb arterial axis variants was classified according to the previously described operative ABC classification. A total of 610 patients were identified. An ABC upper limb arterial axis variant was detected in 156 (25.6%) patients. Variants were right-sided only in 65 (11.0%), left-sided only in 40 (6.6%), and bilateral in 46 (7.5%) patients. Thus, arterial axis variants were significantly more common in the right side (P=0.02). Bilateral arterial variants were significantly associated with age, female sex, and valvulopathy. Both A (radial/brachial) and B (axillary/subclavian/innominate) variants exhibited concordance across the 2 sides (odds ratio, 7.2; 95% confidence interval, 4.1-12.7 and 8.0; 95% confidence interval, 2.1-30.9, respectively). The occurrence of an anatomic variant potentially hindering transradial approach coronary diagnostic or interventional procedures is bilateral in <8% of cases and is more common in the right arm. Such information may guide, during the clinical practice, the access selection in the case of repeat procedures or need for additional accesses. © 2015 American Heart Association, Inc.
Financial impact of emergency department ultrasound.
Soremekun, Olanrewaju A; Noble, Vicki E; Liteplo, Andrew S; Brown, David F M; Zane, Richard D
2009-07-01
There is limited information on the financial implications of an emergency department ultrasound (ED US) program. The authors sought to perform a fiscal analysis of an integrated ED US program. A retrospective review of billing data was performed for fiscal year (FY) 2007 for an urban academic ED with an ED US program. The ED had an annual census of 80,000 visits and 1,101 ED trauma activations. The ED is a core teaching site for a 4-year emergency medicine (EM) residency, has 35 faculty members, and has 24-hour availability of all radiology services including formal US. ED US is utilized as part of evaluation of all trauma activations and for ED procedures. As actual billing charges and reimbursement rates are institution-specific and proprietary information, relative value units (RVUs) and reimbursement based on the Centers for Medicare & Medicaid Services (CMS) 2007 fee schedule (adjusted for fixed diagnosis-related group [DRG] payments and bad debt) was used to determine revenue generated from ED US. To estimate potential volume, assumptions were made on improvement in documentation rate for diagnostic scans (current documentation rates based on billed volume versus diagnostic studies in diagnostic image database), with no improvements assumed for procedural ED US. Expenses consist of three components-capital costs, training costs, and ongoing operational costs-and were determined by institutional experience. Training costs were considered sunken expenses by this institution and were thus not included in the original return on investment (ROI) calculation, although for this article a second ROI calculation was done with training cost estimates included. For the purposes of analysis, certain key assumptions were made. We utilized a collection rate of 45% and hospitalization rates (used to adjust for fixed DRG payments) of 33% for all diagnostic scans, 100% for vascular access, and 10% for needle placement. An optimal documentation rate of 95% was used to estimate potential revenue. In FY 2007, 486 limited echo exams of abdomen (current procedural terminology [CPT] 76705) and 480 limited echo cardiac exams were performed (CPT 93308) while there were 78 exams for US-guided vascular access (CPT 76937) and 36 US-guided needle placements when performing paracentesis, thoracentesis, or location of abscess for drainage (CPT 76492). Applying the 2007 CMS fee schedule and above assumptions, the revenue generated was 578 RVUs and $35,541 ($12,934 in professional physician fees and $22,607 in facility fees). Assuming optimal documentation rates for diagnostic ED US scans, ED US could have generated 1,487 RVUs and $94,593 ($33,953 in professional physician fees and $60,640 in facility fees). Program expenses include an initial capital expense (estimated at $120,000 for two US machines) and ongoing operational costs ($68,640 per year to cover image quality assurance review, continuing education, and program maintenance). Based on current revenue, there would be an annual operating loss, and thus an ROI cannot be calculated. However, if potential revenue is achieved, the annual operating income will be $22,846 per year with an ROI of 4.9 years to break even with initial investment. Determining an ROI is a required procedure for any business plan for establishing an ED US program. Our analysis demonstrates that an ED US program that captures charges for trauma and procedural US and achieves the potential billing volume breaks even in less than 5 years, at which point it would generate a positive margin.
Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design.
Kim, Eunhee; Zhang, Zheng; Wang, Youdan; Zeng, Donglin
2014-12-01
Receiver operating characteristic (ROC) analysis is widely used to evaluate the performance of diagnostic tests with continuous or ordinal responses. A popular study design for assessing the accuracy of diagnostic tests involves multiple readers interpreting multiple diagnostic test results, called the multi-reader, multi-test design. Although several different approaches to analyzing data from this design exist, few methods have discussed the sample size and power issues. In this article, we develop a power formula to compare the correlated areas under the ROC curves (AUC) in a multi-reader, multi-test design. We present a nonparametric approach to estimate and compare the correlated AUCs by extending DeLong et al.'s (1988, Biometrics 44, 837-845) approach. A power formula is derived based on the asymptotic distribution of the nonparametric AUCs. Simulation studies are conducted to demonstrate the performance of the proposed power formula and an example is provided to illustrate the proposed procedure. © 2014, The International Biometric Society.
Clinical and diagnostic utility of saliva as a non-invasive diagnostic fluid: a systematic review
Nunes, Lazaro Alessandro Soares; Mussavira, Sayeeda
2015-01-01
This systematic review presents the latest trends in salivary research and its applications in health and disease. Among the large number of analytes present in saliva, many are affected by diverse physiological and pathological conditions. Further, the non-invasive, easy and cost-effective collection methods prompt an interest in evaluating its diagnostic or prognostic utility. Accumulating data over the past two decades indicates towards the possible utility of saliva to monitor overall health, diagnose and treat various oral or systemic disorders and drug monitoring. Advances in saliva based systems biology has also contributed towards identification of several biomarkers, development of diverse salivary diagnostic kits and other sensitive analytical techniques. However, its utilization should be carefully evaluated in relation to standardization of pre-analytical and analytical variables, such as collection and storage methods, analyte circadian variation, sample recovery, prevention of sample contamination and analytical procedures. In spite of all these challenges, there is an escalating evolution of knowledge with the use of this biological matrix. PMID:26110030
Yang, Tao; Sezer, Hayri; Celik, Ismail B.; ...
2015-06-02
In the present paper, a physics-based procedure combining experiments and multi-physics numerical simulations is developed for overall analysis of SOFCs operational diagnostics and performance predictions. In this procedure, essential information for the fuel cell is extracted first by utilizing empirical polarization analysis in conjunction with experiments and refined by multi-physics numerical simulations via simultaneous analysis and calibration of polarization curve and impedance behavior. The performance at different utilization cases and operating currents is also predicted to confirm the accuracy of the proposed model. It is demonstrated that, with the present electrochemical model, three air/fuel flow conditions are needed to producemore » a set of complete data for better understanding of the processes occurring within SOFCs. After calibration against button cell experiments, the methodology can be used to assess performance of planar cell without further calibration. The proposed methodology would accelerate the calibration process and improve the efficiency of design and diagnostics.« less
Optimal Sensor Selection for Health Monitoring Systems
NASA Technical Reports Server (NTRS)
Santi, L. Michael; Sowers, T. Shane; Aguilar, Robert B.
2005-01-01
Sensor data are the basis for performance and health assessment of most complex systems. Careful selection and implementation of sensors is critical to enable high fidelity system health assessment. A model-based procedure that systematically selects an optimal sensor suite for overall health assessment of a designated host system is described. This procedure, termed the Systematic Sensor Selection Strategy (S4), was developed at NASA John H. Glenn Research Center in order to enhance design phase planning and preparations for in-space propulsion health management systems (HMS). Information and capabilities required to utilize the S4 approach in support of design phase development of robust health diagnostics are outlined. A merit metric that quantifies diagnostic performance and overall risk reduction potential of individual sensor suites is introduced. The conceptual foundation for this merit metric is presented and the algorithmic organization of the S4 optimization process is described. Representative results from S4 analyses of a boost stage rocket engine previously under development as part of NASA's Next Generation Launch Technology (NGLT) program are presented.
Estimating the reliability of eyewitness identifications from police lineups
Wixted, John T.; Mickes, Laura; Dunn, John C.; Clark, Steven E.; Wells, William
2016-01-01
Laboratory-based mock crime studies have often been interpreted to mean that (i) eyewitness confidence in an identification made from a lineup is a weak indicator of accuracy and (ii) sequential lineups are diagnostically superior to traditional simultaneous lineups. Largely as a result, juries are increasingly encouraged to disregard eyewitness confidence, and up to 30% of law enforcement agencies in the United States have adopted the sequential procedure. We conducted a field study of actual eyewitnesses who were assigned to simultaneous or sequential photo lineups in the Houston Police Department over a 1-y period. Identifications were made using a three-point confidence scale, and a signal detection model was used to analyze and interpret the results. Our findings suggest that (i) confidence in an eyewitness identification from a fair lineup is a highly reliable indicator of accuracy and (ii) if there is any difference in diagnostic accuracy between the two lineup formats, it likely favors the simultaneous procedure. PMID:26699467
Estimating the reliability of eyewitness identifications from police lineups.
Wixted, John T; Mickes, Laura; Dunn, John C; Clark, Steven E; Wells, William
2016-01-12
Laboratory-based mock crime studies have often been interpreted to mean that (i) eyewitness confidence in an identification made from a lineup is a weak indicator of accuracy and (ii) sequential lineups are diagnostically superior to traditional simultaneous lineups. Largely as a result, juries are increasingly encouraged to disregard eyewitness confidence, and up to 30% of law enforcement agencies in the United States have adopted the sequential procedure. We conducted a field study of actual eyewitnesses who were assigned to simultaneous or sequential photo lineups in the Houston Police Department over a 1-y period. Identifications were made using a three-point confidence scale, and a signal detection model was used to analyze and interpret the results. Our findings suggest that (i) confidence in an eyewitness identification from a fair lineup is a highly reliable indicator of accuracy and (ii) if there is any difference in diagnostic accuracy between the two lineup formats, it likely favors the simultaneous procedure.
Horká, Marie; Horký, Jaroslav; Kubesová, Anna; Mazanec, Karel; Matousková, Hana; Slais, Karel
2010-07-01
The detection and identification of pathogens currently relies upon a very diverse range of techniques and skills, from traditional cultivation and taxonomic procedures to modern rapid and sensitive diagnostic methods. Real-time PCR is now exploited as a front line diagnostic screening tool in human, animal and plant health as well as bio-security. Nevertheless, new techniques for pathogen identification, particularly of unknown samples, are needed. In this study we propose the combination of electrophoresis-based procedures for the fast differentiation of microorganisms. The method feasibility is proved on the model of seven similar strains of Pseudomonas syringae pathovars from 37 sources, identified by gas chromatography of fatty acid methyl esters. The results from the routine laboratory were compared with results of the combination of the developed capillary and gel electrophoresis as well as mass spectrometry. According to our experiments appropriate combination of electromigration techniques appears to be useful for the fast and economical differentiation of unknown microorganisms.
RANZCR Body Systems Framework of diagnostic imaging examination descriptors.
Pitman, Alexander G; Penlington, Lisa; Doromal, Darren; Slater, Gregory; Vukolova, Natalia
2014-08-01
A unified and logical system of descriptors for diagnostic imaging examinations and procedures is a desirable resource for radiology in Australia and New Zealand and is needed to support core activities of RANZCR. Existing descriptor systems available in Australia and New Zealand (including the Medicare DIST and the ACC Schedule) have significant limitations and are inappropriate for broader clinical application. An anatomically based grid was constructed, with anatomical structures arranged in rows and diagnostic imaging modalities arranged in columns (including nuclear medicine and positron emission tomography). The grid was segregated into five body systems. The cells at the intersection of an anatomical structure row and an imaging modality column were populated with short, formulaic descriptors of the applicable diagnostic imaging examinations. Clinically illogical or physically impossible combinations were 'greyed out'. Where the same examination applied to different anatomical structures, the descriptor was kept identical for the purposes of streamlining. The resulting Body Systems Framework of diagnostic imaging examination descriptors lists all the reasonably common diagnostic imaging examinations currently performed in Australia and New Zealand using a unified grid structure allowing navigation by both referrers and radiologists. The Framework has been placed on the RANZCR website and is available for access free of charge by registered users. The Body Systems Framework of diagnostic imaging examination descriptors is a system of descriptors based on relationships between anatomical structures and imaging modalities. The Framework is now available as a resource and reference point for the radiology profession and to support core College activities. © 2014 The Royal Australian and New Zealand College of Radiologists.
Model-Based Diagnostics for Propellant Loading Systems
NASA Technical Reports Server (NTRS)
Daigle, Matthew John; Foygel, Michael; Smelyanskiy, Vadim N.
2011-01-01
The loading of spacecraft propellants is a complex, risky operation. Therefore, diagnostic solutions are necessary to quickly identify when a fault occurs, so that recovery actions can be taken or an abort procedure can be initiated. Model-based diagnosis solutions, established using an in-depth analysis and understanding of the underlying physical processes, offer the advanced capability to quickly detect and isolate faults, identify their severity, and predict their effects on system performance. We develop a physics-based model of a cryogenic propellant loading system, which describes the complex dynamics of liquid hydrogen filling from a storage tank to an external vehicle tank, as well as the influence of different faults on this process. The model takes into account the main physical processes such as highly nonequilibrium condensation and evaporation of the hydrogen vapor, pressurization, and also the dynamics of liquid hydrogen and vapor flows inside the system in the presence of helium gas. Since the model incorporates multiple faults in the system, it provides a suitable framework for model-based diagnostics and prognostics algorithms. Using this model, we analyze the effects of faults on the system, derive symbolic fault signatures for the purposes of fault isolation, and perform fault identification using a particle filter approach. We demonstrate the detection, isolation, and identification of a number of faults using simulation-based experiments.
ERIC Educational Resources Information Center
Gierl, Mark J.; Cui, Ying
2008-01-01
One promising application of diagnostic classification models (DCM) is in the area of cognitive diagnostic assessment in education. However, the successful application of DCM in educational testing will likely come with a price--and this price may be in the form of new test development procedures and practices required to yield data that satisfy…
Catheter-based treatment of coronary artery disease: past, present, and future.
Holmes, David R; Williams, David O
2008-08-01
September 2007 marked the 30-year anniversary of the first human percutaneous coronary intervention, an index event that changed the course of modern-day cardiovascular care. Before that first procedure, adult invasive cardiology focused on diagnostic angiography as well as hemodynamic assessment of structural heart disease. Since that initial procedure, percutaneous coronary intervention has become the most frequently performed coronary revascularization procedure worldwide. Several factors have been responsible for this dramatic paradigm shift, the most prominent being identification of opportunities for technical improvement and the application of innovation and investigation in concert with colleagues, professional societies, and industry. These approaches will continue to be of paramount importance as new technologies are brought to bear on an increasingly broader group of patients with cardiovascular disease.
Outcomes of children after esophagogastroduodenoscopy for chronic abdominal pain.
Thakkar, Kalpesh; Chen, Leon; Tessier, Mary E; Gilger, Mark A
2014-06-01
Chronic abdominal pain is the most common indication for esophagogastroduodenoscopy (EGD) in children. However, little is known about the accuracy of EGD-based diagnosis or the outcomes of the patients who undergo this procedure. We examined the diagnostic yield of EGD and short-term outcomes of children who underwent this procedure for chronic abdominal pain. We conducted a prospective study of 290 children (4-18 years old; mean age, 11.9 ± 3.5 years; 93 girls) who underwent EGD for the primary indication of chronic abdominal pain (216 with at least 1 alarm feature) at a US pediatric gastroenterology referral center. We collected data on demographic features (age, sex), clinical characteristics (alarm features, Rome III criteria), and EGD results for each patient. All subjects with diagnostic lesions were followed for at least 1 year after EGD to determine short-term outcomes. Overall, EGD provided an accurate diagnosis for 109 children (38%). Diagnoses included esophagitis (21.0%), eosinophilic gastroenteritis (4.1%), eosinophilic esophagitis (3.8%), Helicobacter pylori infection (2.0%), celiac disease (0.6%), and Crohn's disease (0.4%). Short-term outcomes were available for 81% of patients with diagnostic findings, and medical therapy was effective in approximately 67% of these children. EGD is valuable for the diagnosis of children with abdominal pain, with a 38% diagnostic yield. EGD identified disorders for which medical therapy was effective in 67% of children during the year after diagnosis. Copyright © 2014 AGA Institute. Published by Elsevier Inc. All rights reserved.
15-Year-Experience of a Knee Arthroscopist
Tatari, Mehmet Hasan; Bektaş, Yunus Emre; Demirkıran, Demirhan; Ellidokuz, Hülya
2014-01-01
Objectives: Arthroscopic knee surgery is a an experience-demanding procedure throughout diagnostic and reconstructive parts. Altough the literature says that there must be no need for diagnostic arthroscopy today, most arthroscopic surgeons have gained experience and developed themselves by the help of diagnostic arthroscopy and some basic procedures like debridement and lavage. The purpose of this study was to observe what happenned in the 15-year-experience of an orthopaedic surgeon who deals with knee arthroscopy. The hypothesis was that the mean age of the patients, who have undergone arthroscopic procedures, would decrease, and the percentage of the diagnostic and debridement applications would diminish and reconstructive procedures would increase. Methods: For this purpose, 959 patients who have undergone knee arthroscopy in 15 years, were evaluated retrospectively. The gender, age, operation year and the procedure applied for the patients were enrolled on an Excel file. Chi-Square test was used for statistical evaluation. The patients were divided into three groups according to the year they were operated. Period 1 included the patients who were operated between the years 1999-2003, Period 2 between 2004-2008 and Period 3 between 2009-2013. According to their ages, the patients were evaluated in three groups; Group 1 included the patients ≤ 25 years old while Group 2 between 26-40 and Group 3 ≥ 41. Arthroscopic procedures were evaluated in three groups: Group X: meniscectomy, chondral debridement, lavage, synoviectomy, loose body removal. Group Y: ACL and PCL reconstruction, meniscal repair. Group Z: Microfracture, lateral release, meniscal normalization, second look arthroscopy, diagnostic arthroscopy before osteotomy. Results: Among all patients, 60 % was male and Group 3 (45.4 %) was the larger group in population. The procedures in Group X were used in most of the operations ( 59.2 %). The population of the patients in the periods increased gradually throughout the years: 24 % in Period 1, 36.6 % in Period 2 and 39.4 % in Period 3. While the population of Group 3 was higher than the others in the first two periods, Group 2 was the leader in the last period (p< 0.001). While male/female ratio was statistically insignificant in Periods 1 and 2, the number of the males in Period 3 was statistically higher than the females (p< 0.001). The procedures in Group Y were used significantly for males in Periods 2 and 3 (p< 0.001). The procedures in Group X were used significantly for females (p< 0.001) while the ones in Group Y were applied for males (p< 0.001). Among all arthroscopic procedures, Group X was the leader in Period 1 (85 %) but this frequency decreased throughout the years and the procedures in Group Y increased gradually more than twice consisting more than half of the procedures in Period 3 (p< 0.001). Conclusion: Throughout the years, the age of the patients, for whom arthroscopic procedures were done, and the percentage of debridement and diagnostic procedures have decreased, while the population of the patients and the number of the reconstructive procedures, especially for males, have increased. The results were statistically significant. In our opinion, this statistical conclusion must be the usual academic development of an orthopeadic surgeon who deals mostly with knee arthroscopy in his daily practice. This must be a guide for young arthroscopists.
[Possibilities of sonographic image fusion: Current developments].
Jung, E M; Clevert, D-A
2015-11-01
For diagnostic and interventional procedures ultrasound (US) image fusion can be used as a complementary imaging technique. Image fusion has the advantage of real time imaging and can be combined with other cross-sectional imaging techniques. With the introduction of US contrast agents sonography and image fusion have gained more importance in the detection and characterization of liver lesions. Fusion of US images with computed tomography (CT) or magnetic resonance imaging (MRI) facilitates the diagnostics and postinterventional therapy control. In addition to the primary application of image fusion in the diagnosis and treatment of liver lesions, there are more useful indications for contrast-enhanced US (CEUS) in routine clinical diagnostic procedures, such as intraoperative US (IOUS), vascular imaging and diagnostics of other organs, such as the kidneys and prostate gland.
Bashir, Qasim; Ishfaq, Asim; Baig, Ammad Anwar
2018-02-01
Digital subtraction angiography (DSA) remains the gold standard imaging modality for cerebrovascular disorders. In contrast to developed countries, the safety of the procedure is not extensively reported from the developing countries. Herein, we present a retrospective analysis of the basic technique, indications, and outcomes in 286 patients undergoing diagnostic cerebral and spinal angiography in a developing country, Pakistan. A retrospective review of patient demographics, procedural technique and complication rates of 286 consecutive patients undergoing the diagnostic cerebral/spinal angiography procedure at one institution from May 2013 to December 2015 was performed. Neurological, systemic, or local complications occurring within and after 24 h of the procedure were recorded. Mean age reported for all patients was 49.7 years. Of all the 286 cases, 175 were male (61.2%) and the rest female (111, 38.8%). Cerebral DSA was performed in 279 cases (97.6%), with 7 cases of spinal DSA (2.4%). Subarachnoid hemorrhage was the most common indication for DSA accounting for 88 cases (30.8%), closely followed by stroke (26.6%) and arteriosclerotic vascular disease (23.1%). No intra- or post-procedural neurological complications of any severity were seen in any of the 286 cases. One case of asymptomatic aortic dissection was reported (0.3%) in the entire cohort of patient population. Diagnostic cerebral/spinal digital subtraction angiography was found to be safe in Pakistan, with complication rates at par with and comparable to those reported in the developed world.
General considerations and updates in pediatric gastrointestinal diagnostic endoscopy
2010-01-01
Gastrointestinal and colonic endoscopic examinations have been performed in pediatric patients in Korea for 3 decades. Endoscopic procedures are complex and may be unsafe if special concerns are not considered. Many things have to be kept in mind before, during, and after the procedure. Gastrointestinal endoscopy is one of the most frequently performed procedure in children nowadays, Since the dimension size of the endoscopy was modified for pediatric patients 15 years ago, endoscopic procedures are almost performed routinely in pediatric gastrointestinal patients. The smaller size of the scope let the physicians approach the diagnostic and therapeutic endoscopic procedures. But this is an invasive procedure, so the procedure itself may provoke an emergence state. The procedure-related complications can more easily occur in pediatric patients. Sedation-related or procedure-related respiratory, cardiovascular complications are mostly important and critical in the care. The endoscopists are required to consider diverse aspects of the procedure - patient preparation, indications and contraindications, infection controls, sedation methods, sedative medicines and the side effects of each medicine, monitoring during and after the procedure, and complications related with the procedure and medicines - to perform the procedure successfully and safely. This article presents some important guidelines and recommendations for gastrointestinal endoscopy through literature review. PMID:21189965
Nursing Procedures. NAVMED P-5066.
ERIC Educational Resources Information Center
Bureau of Medicine and Surgery (Navy), Washington, DC.
The revised manual of nursing procedures covers fundamental nursing care, admission and discharge of the patient, assisting with therapeutic measures, pre- and postoperative care, diagnostic tests and procedures, and isolation technique. Each of the over 300 topics includes the purpose, equipment, and procedure to be used and, where relevant, such…
Dent, Andrew W; Weiland, Tracey J; Paltridge, Debbie
2008-06-01
To report the preferences of Fellows of the Australasian College for Emergency Medicine for topics they would desire for their continuing professional development (CPD). A mailed survey of Fellows of the Australasian College for Emergency Medicine asked for Likert type responses on the desirability of CPD on 15 procedural skills, 13 management skills, 11 clinical emergency topics, 9 topics related to teaching, 7 related to diagnostics and 5 evidence based practice topics. CPD in procedural skills of advanced and surgical airways, ED ultrasound, ventilation, skills, plastic procedures and regional anaesthesia were nominated as desirable by 85% of emergency physicians (EP). More than 90% desired CPD in ophthalmological, otorhinolaryngeal, neonatal and paediatric emergencies. Of diagnostic skills, more than 80% considered CPD on computerized tomography, electrocardiography and plain X-ray interpretation as desirable, well as CPD about teaching in general, simulation and preparing candidates for fellowship exams. Of the 12 management skills, 11 were seen as desirable topics by more than 70%, with counter disaster planning, giving feedback and dealing with complaints the most popular. All evidence based practice related skills, including interpreting statistics and undertaking literature searches were seen as desirable topics by more than 80% of EP. This information may assist in the planning of future educational interventions for emergency physicians. EP seek CPD on management, educational and other non clinical skills, as well as topics relating directly to patient care.
Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Economic Analysis
Palimaka, S; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Small-bowel capsule endoscopy is a tool used to visualize the small bowel to identify the location of bleeds in obscure gastrointestinal bleeding (OGIB). Capsule endoscopy is currently funded in Ontario in cases where there has been a failure to identify a source of bleeding via conventional diagnostic procedures. In Ontario, capsule endoscopy is a diagnostic option for patients whose findings on esophagogastroduodenoscopy, colonoscopy, and push enteroscopy have been negative (i.e., the source of bleeding was not found). Objectives This economic analysis aims to estimate the budget impact of different rates of capsule endoscopy use as a complement to push enteroscopy procedures in patients aged 18 years and older. Data Sources Population-based administrative databases for Ontario were used to identify patients receiving push enteroscopy and small-bowel capsule endoscopy in the fiscal years 2008 to 2012. Review Methods A systematic literature search was performed to identify economic evaluations of capsule endoscopy for the investigation of OGIB. Studies were assessed for their methodological quality and their applicability to the Ontarian setting. An original budget impact analysis was performed using data from Ontarian administrative sources and published literature. The budget impact was estimated for different levels of use of capsule endoscopy as a complement to push enteroscopy due to the uncertain clinical utility of the capsule based on current clinical evidence. The analysis was conducted from the provincial public payer perspective. Results With varying rates of capsule endoscopy use, the budgetary impact spans from savings of $510,000,1 when no (0%) push enteroscopy procedures are complemented with capsule endoscopy, to $2,036,000, when all (100%) push enteroscopy procedures are complemented with capsule endoscopy. A scenario where 50% of push enteroscopy procedures are complemented with capsule endoscopy (expected use based on expert opinion) would result in additional expenditure of about $763,000. Limitations In the literature on OGIB, estimates of rebleeding rates after endoscopic procedures or spontaneous cessation rates are unreliable, with a lack of data. Rough estimates from expert consultation can provide an indication of expected additional use of capsule endoscopy; however, a wide range of capsule uses was explored. Conclusions The budgetary impact in the first year in Ontario of capsule endoscopy use to complement push enteroscopy procedures ranges from $510,000 in savings to an additional expenditure of $2,036,000 (at 0% and 100% push enteroscopy procedures complemented, respectively). The expected scenario of 50% of push enteroscopy procedures likely to benefit from the use of capsule endoscopy, based on expert opinion, would result in additional expenditures of $763,000 in the first year. PMID:26355732
Infliximab use in Crohn's disease: impact on health care resources in the UK.
Jewell, Derek P; Satsangi, Jack; Lobo, Alan; Probert, Christopher; Forbes, Alastair; Ghosh, Subrata; Shaffer, Jon; Frenz, Markus; Drummond, Hazel; Troy, Gill; Turner, Sue; Younge, Lisa; Evans, Lyn; Moosa, Mark; Rodgers-Gray, Barry; Buchan, Scot
2005-10-01
To quantify the impact of infliximab therapy on health care resource utilization in the UK. A retrospective audit was undertaken at seven centres in the UK, which reviewed patient notes for a period of 6 months before and 6 months after an initial infliximab infusion. Details of hospital admissions, outpatient visits, operations, diagnostic procedures, drug usage, and overall efficacy were collected. Results were compared for the two 6 month study periods. A total of 205 patients (62% female, median age 33 years) with moderate/severe Crohn's disease were audited. The majority of patients had chronic active disease (62%) and most received one infusion initially (72%). Clinicians rated 74% of responses as good to excellent and patients 72%. Most patients had concomitant immunosuppression (pre: 75%, post: 75%). Approximately half of the patients (45%) stopped taking steroids, with a further 34% having a dosage reduction. A fall of 1093 inpatient days was seen (1435 vs. 342) in the 6 months following infliximab administration. There were seven fewer operations, 33 fewer examinations under anaesthetic, and 99 fewer diagnostic procedures. Outpatient visits were similar pre- versus post- (555 vs. 534). The total reduction in direct costs amounted to an estimated pounds 591,006. Three hundred and fifty-three infliximab infusions were administered at an estimated cost of pounds 562,719. Thus, there was a net reduction of pounds 28,287 or pounds 137.98 per patient. Infliximab appears to be a potentially cost effective treatment for selected patients based on the reduced number of inpatient stays, examinations under anaesthetic, and diagnostic procedures over a 6 month period.
On-the-fly detection of images with gastritis aspects in magnetically guided capsule endoscopy
NASA Astrophysics Data System (ADS)
Mewes, P. W.; Neumann, D.; Juloski, A. L.; Angelopoulou, E.; Hornegger, J.
2011-03-01
Capsule Endoscopy (CE) was introduced in 2000 and has since become an established diagnostic procedure for the small bowel, colon and esophagus. For the CE examination the patient swallows the capsule, which then travels through the gastrointestinal tract under the influence of the peristaltic movements. CE is not indicated for stomach examination, as the capsule movements can not be controlled from the outside and the entire surface of the stomach can not be reliably covered. Magnetically-guided capsule endoscopy (MGCE) was introduced in 2010. For the MGCE procedure the stomach is filled with water and the capsule is navigated from the outside using an external magnetic field. During the examination the operator can control the motion of the capsule in order to obtain a sufficient number of stomach-surface images with diagnostic value. The quality of the examination depends on the skill of the operator and his ability to detect aspects of interest in real time. We present a novel computer-assisted diagnostic-procedure (CADP) algorithm for indicating gastritis pathologies in the stomach during the examination. Our algorithm is based on pre-processing methods and feature vectors that are suitably chosen for the challenges of the MGCE imaging (suspended particles, bubbles, lighting). An image is classified using an ada-boost trained classifier. For the classifier training, a number of possible features were investigated. Statistical evaluation was conducted to identify relevant features with discriminative potential. The proposed algorithm was tested on 12 video sequences stemming from 6 volunteers. A mean detection rate of 91.17% was achieved during leave-one out cross-validation.
Electromagnetic Navigation Diagnostic Bronchoscopy
Gildea, Thomas R.; Mazzone, Peter J.; Karnak, Demet; Meziane, Moulay; Mehta, Atul C.
2006-01-01
Rationale: Electromagnetic navigation bronchoscopy using superDimension/Bronchus System is a novel method to increase diagnostic yield of peripheral and mediastinal lung lesions. Objectives: A prospective, open label, single-center, pilot study was conducted to determine the ability of electromagnetic navigation bronchoscopy to sample peripheral lung lesions and mediastinal lymph nodes with standard bronchoscopic instruments and demonstrate safety. Methods: Electromagnetic navigation bronchoscopy was performed using the superDimension/Bronchus system consisting of electromagnetic board, position sensor encapsulated in the tip of a steerable probe, extended working channel, and real-time reconstruction of previously acquired multiplanar computed tomography images. The final distance of the steerable probe to lesion, expected error based on the actual and virtual markers, and procedure yield was gathered. Measurements: 60 subjects were enrolled between December 2004 and September 2005. Mean navigation times were 7 ± 6 min and 2 ± 2 min for peripheral lesions and lymph nodes, respectively. The steerable probe tip was navigated to the target lung area in all cases. The mean peripheral lesions and lymph nodes size was 22.8 ± 12.6 mm and 28.1 ± 12.8 mm. Yield was determined by results obtained during the bronchoscopy per patient. Results: The yield/procedure was 74% and 100% for peripheral lesions and lymph nodes, respectively. A diagnosis was obtained in 80.3% of bronchoscopic procedures. A definitive diagnosis of lung malignancy was made in 74.4% of subjects. Pneumothorax occurred in two subjects. Conclusion: Electromagnetic navigation bronchoscopy is a safe method for sampling peripheral and mediastinal lesions with high diagnostic yield independent of lesion size and location. PMID:16873767
Virtual reality in rhinology-a new dimension of clinical experience.
Klapan, Ivica; Raos, Pero; Galeta, Tomislav; Kubat, Goranka
2016-07-01
There is often a need to more precisely identify the extent of pathology and the fine elements of intracranial anatomic features during the diagnostic process and during many operations in the nose, sinus, orbit, and skull base region. In two case reports, we describe the methods used in the diagnostic workup and surgical therapy in the nose and paranasal sinus region. Besides baseline x-ray, multislice computed tomography, and magnetic resonance imaging, operative field imaging was performed via a rapid prototyping model, virtual endoscopy, and 3-D imaging. Different head tissues were visualized in different colors, showing their anatomic interrelations and the extent of pathologic tissue within the operative field. This approach has not yet been used as a standard preoperative or intraoperative procedure in otorhinolaryngology. In this way, we tried to understand the new, visualized "world of anatomic relations within the patient's head" by creating an impression of perception (virtual perception) of the given position of all elements in a particular anatomic region of the head, which does not exist in the real world (virtual world). This approach was aimed at upgrading the diagnostic workup and surgical therapy by ensuring a faster, safer and, above all, simpler operative procedure. In conclusion, any ENT specialist can provide virtual reality support in implementing surgical procedures, with additional control of risks and within the limits of normal tissue, without additional trauma to the surrounding tissue in the anatomic region. At the same time, the virtual reality support provides an impression of the virtual world as the specialist navigates through it and manipulates virtual objects.
Ambulatory Care Data Base (ACDB) Data Dictionary Sequential Files of Phase 2.
1992-04-01
ARTERIES 4340 CEREBRAL THROMBOSIS 43491 STROKE , ISCHEMIC 435 TRANSIENT CEREBRAL ISCHEMIA 4359 TRANSIENT ISCHEMIC ATTACK (TIA) 43591 TRANS ISCHEMIC ATTACK W...CRISIS 4373 ANEURYSM, CEREBRAL , NONRUPTURED 4374 ARTERITIS, CEREBRAL 4378 CEREBROVASCULAR DISEASE, OTHER ILL-DEFINED 43781 STROKE , LACUNAR 438 LATE...FOR LOCALIZATION OF CEREBRAL SEIZURE FOC 95999 OTHER NEUROLOGICAL DIAGNOSTIC PROCEDURES 96500 CHEMO INJ, SINGLE, PRE-MIX, PUSH 96501 CHEMO INJ, SINGLE
ERIC Educational Resources Information Center
Herrmann-Abell, Cari F.; DeBoer, George E.
2011-01-01
Distractor-driven multiple-choice assessment items and Rasch modeling were used as diagnostic tools to investigate students' understanding of middle school chemistry ideas. Ninety-one items were developed according to a procedure that ensured content alignment to the targeted standards and construct validity. The items were administered to 13360…
Aust, H; Veltum, B; Wächtershäuser, T; Eberhart, L; Wulf, H; Rüsch, D
2013-05-01
The German Societies of Anesthesiology and Intensive Care Medicine, Internal Medicine and Surgery have recently published for the first time joint recommendations for the evaluation of adult patients prior to elective non-cardiac surgery. In these recommendations indications for preoperative diagnostic procedures were critically revised and updated. It was unclear to what extent these recommendations were known among German anesthesiologists, how the recommendations were perceived and to what extent they were put into practice. The indications of five common diagnostic procedures in the context of the preoperative evaluation were also unknown. Three months after publication of the recommendations, all anesthesiologists employed at hospitals in the state of Hessen were requested to take part in an online survey (OS). In the first part of the OS participants were asked about familiarity with the recommendations, opinions concerning the utility of the recommendations and to what extent they were implemented. In the second part of the OS participants were questioned in general and in the context of two common case scenarios about indications for electrocardiograms (ECG), chest radiographs (chest x-ray), echocardiograms, spirometry and extended cardiac diagnostics, such as stress ECG. In addition, participants of the OS were requested to take part in an interview survey (IS) addressing the same topics. The purpose of the IS was to detect any bias caused by the anonymous character of the OS which could lead to an overestimated self-assessment. Answers of the IS were not compared to the results of the corresponding answers given online by the same anesthesiologist but only analyzed together with the other results of the IS for comparison with the results of the OS. Of the contacted anesthesiologists 396 (29 %) took part in the OS of which 100 took part in the IS. According to the OS 30 % were familiar and 34 % were partially familiar with the recommendations, 20 % just knew that recommendations had been published and 16 % did not even know about the publication. The corresponding results of the IS were 16 %, 36 %, 28 % and 20 %, respectively. Of the participants 90 % (OS) and 89 % (IS) considered the recommendations at least to be predominantly reasonable and useful and 66 % (OS) of the participants tried to implement or at least to partially implement the recommendations (IS only 33 %). Concerning the indications for the different diagnostic procedures, the results of the OS showed that hospital guidelines (44 %) and patient age (32 %) were the most frequent indications for a preoperative ECG. Hospital guidelines (40 %) and own judgement (39 %) were the most common indications for a preoperative chest x-ray and patient age still accounted for 18 % of the indications. In contrast, echocardiography (67 %), spirometry (61 %) and extended cardiac diagnostics (70 %) were primarily indicated based on own judgement. However, reasons given in this context were frequently (77 %) not in agreement with the recommendations. Comparing the results of the OS to those of the IS with respect to the indications of the different diagnostic procedures for the common case scenarios showed a varying degree of consistency with the recommendations. In both cases responses to the IS concerning the indications for the different diagnostic procedures were mostly in accordance with the recommendations compared to answers obtained in the OS. Indications for the chest x-ray showed the worst degree of consistency with the recommendations. Corresponding to the high significance of local standards for the decision of indicating preoperative diagnostic procedures, the development of local standards that are in agreement with the recommendations seems to be a reasonable way to facilitate the implementation of the recommendations.
Multispectral autofluorescence diagnosis of non-melanoma cutaneous tumors
NASA Astrophysics Data System (ADS)
Borisova, Ekaterina; Dogandjiiska, Daniela; Bliznakova, Irina; Avramov, Latchezar; Pavlova, Elmira; Troyanova, Petranka
2009-07-01
Fluorescent analysis of basal cell carcinoma (BCC), squamous cell carcinoma (SCC), keratoacanthoma and benign cutaneous lesions is carried out under initial phase of clinical trial in the National Oncological Center - Sofia. Excitation sources with maximum of emission at 365, 380, 405, 450 and 630 nm are applied for better differentiation between nonmelanoma malignant cutaneous lesions fluorescence and spectral discrimination from the benign pathologies. Major spectral features are addressed and diagnostic discrimination algorithms based on lesions' emission properties are proposed. The diagnostic algorithms and evaluation procedures found will be applied for development of an optical biopsy clinical system for skin cancer detection in the frames of National Oncological Center and other university hospital dermatological departments in our country.
A systems engineering approach to automated failure cause diagnosis in space power systems
NASA Technical Reports Server (NTRS)
Dolce, James L.; Faymon, Karl A.
1987-01-01
Automatic failure-cause diagnosis is a key element in autonomous operation of space power systems such as Space Station's. A rule-based diagnostic system has been developed for determining the cause of degraded performance. The knowledge required for such diagnosis is elicited from the system engineering process by using traditional failure analysis techniques. Symptoms, failures, causes, and detector information are represented with structured data; and diagnostic procedural knowledge is represented with rules. Detected symptoms instantiate failure modes and possible causes consistent with currently held beliefs about the likelihood of the cause. A diagnosis concludes with an explanation of the observed symptoms in terms of a chain of possible causes and subcauses.
Artemenko, M V
2008-01-01
Two approaches to calculation of the qualitative measures for assessing the functional state level of human body are considered. These approaches are based on image and fuzzy set recognition theories and are used to construct diagnostic decision rules. The first approach uses the data on deviation of detected parameters from those for healthy persons; the second approach analyzes the degree of deviation of detected parameters from the approximants characterizing the correlation differences between the parameters. A method for synthesis of decision rules and the results of blood count-based research for a number of diseases (hemophilia, thrombocytopathy, hypertension, arrhythmia, hepatic cirrhosis, trichophytia) are considered. An effect of a change in the functional link between the cholesterol content in blood and the relative rate of variation of AST and ALT enzymes in blood from direct proportional (healthy state) to inverse proportional (hepatic cirrhosis) is discussed. It is shown that analysis of correlation changes in detected parameters of the human body state during diagnostic process is more effective for application in decision support systems than the state space analysis.
Cisneros-Herreros, José Miguel; Cobo-Reinoso, Javier; Pujol-Rojo, Miquel; Rodríguez-Baño, Jesús; Salavert-Lletí, Miguel
2007-02-01
Bacteremia is a complex clinical syndrome in constant transformation that is an important, growing cause of morbidity and mortality. Even though there is a great deal of specific information about bacteremia, few comprehensive reviews integrate this information with a practical AIM. The main objective of these Guidelines, which target hospital physicians, is to improve the clinical care provided to patients with bacteremia by integrating blood culture results with clinical data, and optimizing the use of diagnostic procedures and antimicrobial testing. The document is structured into sections that cover the epidemiology and etiology of bacteremia, stratified according to the various patient populations, and the diagnostic work-up, therapy, and follow-up of patients with bacteremia. Diagnostic and therapeutic decisions are presented as recommendations based on the grade of available scientific evidence.
Exosomal microRNA Biomarkers: Emerging Frontiers in Colorectal and Other Human Cancers
Goel, Ajay; Tovar-Camargo, Oscar A; Toden, Shusuke
2016-01-01
Diagnostic strategies, particularly non-invasive blood-based screening approaches, are gaining increased attention for the early detection and attenuation of mortality associated with colorectal cancer (CRC). However, the majority of current screening approaches are inadequate at replacing the conventional CRC diagnostic procedures. Yet, due to technological advances and a better understanding of molecular events underlying human cancer, a new category of biomarkers are on the horizon. Recent evidence indicates that cells release a distinct class of small vesicles called ‘exosomes’, which contain nucleic acids and proteins that reflect and typify host-cell molecular architecture. Intriguingly, exosomes released from cancer cells have a distinct genetic and epigenetic makeup, which allows them to undertake their tumorigenic function. From a clinical standpoint, these unique cancer-specific fingerprints present in exosomes appear to be detectable in a small amount of blood, making them very attractive substrates for developing cancer biomarkers, particularly noninvasive diagnostic approaches. PMID:26892862
Brun, E; Grandl, S; Sztrókay-Gaul, A; Barbone, G; Mittone, A; Gasilov, S; Bravin, A; Coan, P
2014-11-01
Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure's possible applications. A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.
Assessing Disease Class-Specific Diagnostic Ability: A Practical Adaptive Test Approach.
ERIC Educational Resources Information Center
Papa, Frank J.; Schumacker, Randall E.
Measures of the robustness of disease class-specific diagnostic concepts could play a central role in training programs designed to assure the development of diagnostic competence. In the pilot study, the authors used disease/sign-symptom conditional probability estimates, Monte Carlo procedures, and artificial intelligence (AI) tools to create…
Fritz, Jan; Henes, Jörg C; Thomas, Christoph; Clasen, Stephan; Fenchel, Michael; Claussen, Claus D; Lewin, Jonathan S; Pereira, Philippe L
2008-12-01
The objective of our study was to prospectively test the hypothesis that combined diagnostic and interventional MRI of the sacroiliac joints can be performed efficiently and effectively. Over a 12-month period, 60 patients (32 women and 28 men; median age, 28 years; age range, 18-49 years) with chronic lower back pain suspected to originate from the sacroiliac joints were enrolled in the study. Based on diagnostic MRI findings, MR fluoroscopy-guided sacroiliac joint injections were performed in 57 (95%) patients. Diagnostic injections (35, 58.3%) were performed if nonspecific or degenerative MRI findings were present. Therapeutic injections (22, 36.7%) were performed in patients with inflammatory arthropathy. In three (5%) patients, no injections were performed. Technical effectiveness was assessed by analyzing, first, the rate of intraarticular injection; second, the time required for the procedure; third, image quality; and, fourth, occurrence of complications and clinical outcome by analyzing pain intensity changes and volume and signal intensity of sacroiliac inflammatory changes. The rate of intraarticular injection was 90.4% (103/114). The mean length of time for the procedure was 50 minutes (range, 34-103 minutes), with exponential shortening over time (p < or = 0.001). The contrast-to-noise ratios of the needle and tissues were sufficiently different for excellent delineation of the needle. No complications occurred. Diagnostic injections identified the sacroiliac joints as generating significant pain in 46.9% (15/32) of the patients. Three months after therapeutic injections, pain intensity had decreased by 62.5% (p < or = 0.001) and the volume and relative signal intensity of inflammatory changes had decreased by 37.5% (p = 0.003) and 47.6% (p < or = 0.001), respectively. We accept the hypothesis that combined diagnostic and interventional MRI of the sacroiliac joints can be performed efficiently and effectively for comprehensive diagnosis and therapy of lower back pain originating from the sacroiliac joints.
X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... Chernecky CC, Berger BJ. Radiography of skull, chest, and cervical spine - diagnostic. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. ...
Transoesophageal echocardiography in the dog.
Domenech, Oriol; Oliveira, Pedro
2013-11-01
Transoesophageal echocardiography (TEE) allows imaging of the heart through the oesophagus using a special transducer mounted on a modified endoscope. The proximity to the heart and minimal intervening structures enables the acquisition of high-resolution images that are consistently superior to routine transthoracic echocardiography and optimal imaging of the heart base anatomy and related structures. TEE provides high-quality real-time imaging free of ionizing radiation, making it an ideal instrument not only for diagnostic purposes, but also for monitoring surgical or minimally invasive cardiac procedures, non-cardiac procedures and critical cases in the intensive care unit. In human medicine, TEE is routinely used in these settings. In veterinary medicine, TEE is increasingly used in referral centres, especially for perioperative assessment and guidance of catheter-based cardiovascular procedures, such as patent ductus arteriosus, balloon valvuloplasty, and atrial and ventricular septal defect occlusion with vascular devices. TEE can also aid in heartworm retrieval procedures. The purpose of this paper is to review the current uses of TEE in veterinary medicine, focusing on technique, indications and complications. Copyright © 2013 Elsevier Ltd. All rights reserved.
The IHS diagnostic X-ray equipment radiation protection program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knapp, A.; Byrns, G.; Suleiman, O.
The Indian Health Service (IHS) operates or contracts with Tribal groups to operate 50 hospitals and approximately 165 primary ambulatory care centers. These facilities contain approximately 275 medical and 800 dental diagnostic x-ray machines. IHS environmental health personnel in collaboration with the Food and Drug Administration's (FDA) Center for Devices and Radiological Health (CDRH) developed a diagnostic x-ray protection program including standard survey procedures and menu-driven calculations software. Important features of the program include the evaluation of equipment performance collection of average patient entrance skin exposure (ESE) measurements for selected procedures, and quality assurance. The ESE data, collected using themore » National Evaluation of X-ray Trends (NEXT) protocol, will be presented. The IHS Diagnostic X-ray Radiation Protection Program is dynamic and is adapting to changes in technology and workload.« less
Development of an activity-based costing model to evaluate physician office practice profitability.
Dugel, Pravin U; Tong, Kuo Bianchini
2011-01-01
Newer treatment regimens for age-related macular degeneration have significantly affected traditional and non-traditional retinal services across all types of practice settings around the country as they seek to find a balance among delivering best patient care, keeping operating costs under control, and maintaining profitability. A systematic retrospective review of a multi-city, multi-physician retinal practice's accounting system to obtain data on revenues, expenses, and profit. Data reviewed were from practice management systems to obtain claims level data on clinical procedures across 7 primary activity centers: non-laser surgery, laser surgery, office visits, optical coherence tomography (OCT), non-OCT diagnostics, drugs and drug injections, and research. All treated patients from a retina practice from January 1, 2005, to December 31, 2007. Retrospective claims data review from a multi-physician retina practice detailing Current Procedural Terminology and Healthcare Common Procedure Coding System procedures performed and billed, submitted charges, allowed charges, and net collections. Analyses were performed by an outside firm and verified by a risk advisory firm. Identifying practice efficiencies/inefficiencies as they relate to patient care. An elaborate analysis using activity-based costing (ABC) showed that increased office visits and OCT and non-OCT diagnostics had a significant negative impact on the practice's profit margins, whereas surgical procedures contributed to the majority of the practice's profit margins because of the lower operating costs associated with surgery. The practice was able to accommodate the demand in patient volume, medical retina services, and medical imaging with the advent of anti-vascular endothelial growth factor therapy and realized a seismic shift in operating costs. The practice attempted to deliver state-of-the-art patient care in a cost-effective manner, yet underwent a significant decline in its financial health. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Colonoscopy video quality assessment using hidden Markov random fields
NASA Astrophysics Data System (ADS)
Park, Sun Young; Sargent, Dusty; Spofford, Inbar; Vosburgh, Kirby
2011-03-01
With colonoscopy becoming a common procedure for individuals aged 50 or more who are at risk of developing colorectal cancer (CRC), colon video data is being accumulated at an ever increasing rate. However, the clinically valuable information contained in these videos is not being maximally exploited to improve patient care and accelerate the development of new screening methods. One of the well-known difficulties in colonoscopy video analysis is the abundance of frames with no diagnostic information. Approximately 40% - 50% of the frames in a colonoscopy video are contaminated by noise, acquisition errors, glare, blur, and uneven illumination. Therefore, filtering out low quality frames containing no diagnostic information can significantly improve the efficiency of colonoscopy video analysis. To address this challenge, we present a quality assessment algorithm to detect and remove low quality, uninformative frames. The goal of our algorithm is to discard low quality frames while retaining all diagnostically relevant information. Our algorithm is based on a hidden Markov model (HMM) in combination with two measures of data quality to filter out uninformative frames. Furthermore, we present a two-level framework based on an embedded hidden Markov model (EHHM) to incorporate the proposed quality assessment algorithm into a complete, automated diagnostic image analysis system for colonoscopy video.
[Microbiological point of care tests].
Book, Malte; Lehmann, Lutz Eric; Zhang, Xianghong; Stüber, Frank
2010-11-01
It is well known that the early initiation of a specific antiinfective therapy is crucial to reduce the mortality in severe infection. Procedures culturing pathogens are the diagnostic gold standard in such diseases. However, these methods yield results earliest between 24 to 48 hours. Therefore, severe infections such as sepsis need to be treated with an empirical antimicrobial therapy, which is ineffective in an unknown fraction of these patients. Today's microbiological point of care tests are pathogen specific and therefore not appropriate for an infection with a variety of possible pathogens. Molecular nucleic acid diagnostics such as polymerase chain reaction (PCR) allow the identification of pathogens and resistances. These methods are used routinely to speed up the analysis of positive blood cultures. The newest PCR based system allows the identification of the 25 most frequent sepsis pathogens by PCR in parallel without previous culture in less than 6 hours. Thereby, these systems might shorten the time of possibly insufficient antiinfective therapy. However, these extensive tools are not suitable as point of care diagnostics. Miniaturization and automating of the nucleic acid based method is pending, as well as an increase of detectable pathogens and resistance genes by these methods. It is assumed that molecular PCR techniques will have an increasing impact on microbiological diagnostics in the future. © Georg Thieme Verlag Stuttgart · New York.
CT and MRI slice separation evaluation by LabView developed software.
Acri, Giuseppe; Testagrossa, Barbara; Sestito, Angela; Bonanno, Lilla; Vermiglio, Giuseppe
2018-02-01
The efficient use of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) equipment necessitates establishing adequate quality-control (QC) procedures. In particular, the accuracy of slice separation, during multislices acquisition, requires scan exploration of phantoms containing test objects. To simplify such procedures, a novel phantom and a computerised LabView-based procedure have been devised, enabling determination the midpoint of full width at half maximum (FWHM) in real time while the distance from the profile midpoint of two progressive images is evaluated and measured. The results were compared with those obtained by processing the same phantom images with commercial software. To validate the proposed methodology the Fisher test was conducted on the resulting data sets. In all cases, there was no statistically significant variation between the commercial procedure and the LabView one, which can be used on any CT and MRI diagnostic devices. Copyright © 2017. Published by Elsevier GmbH.
A prototype knowledge-based simulation support system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, T.R.; Roberts, S.D.
1987-04-01
As a preliminary step toward the goal of an intelligent automated system for simulation modeling support, we explore the feasibility of the overall concept by generating and testing a prototypical framework. A prototype knowledge-based computer system was developed to support a senior level course in industrial engineering so that the overall feasibility of an expert simulation support system could be studied in a controlled and observable setting. The system behavior mimics the diagnostic (intelligent) process performed by the course instructor and teaching assistants, finding logical errors in INSIGHT simulation models and recommending appropriate corrective measures. The system was programmed inmore » a non-procedural language (PROLOG) and designed to run interactively with students working on course homework and projects. The knowledge-based structure supports intelligent behavior, providing its users with access to an evolving accumulation of expert diagnostic knowledge. The non-procedural approach facilitates the maintenance of the system and helps merge the roles of expert and knowledge engineer by allowing new knowledge to be easily incorporated without regard to the existing flow of control. The background, features and design of the system are describe and preliminary results are reported. Initial success is judged to demonstrate the utility of the reported approach and support the ultimate goal of an intelligent modeling system which can support simulation modelers outside the classroom environment. Finally, future extensions are suggested.« less
Henninger, B.; Putzer, D.; Kendler, D.; Uprimny, C.; Virgolini, I.; Gunsilius, E.; Bale, R.
2012-01-01
Aim. The purpose of this study was to evaluate the accuracy of 2-deoxy-2-[fluorine-18]fluoro-D-glucose (FDG) positron emission tomography (PET), computed tomography (CT), and software-based image fusion of both modalities in the imaging of non-Hodgkin's lymphoma (NHL) and Hodgkin's disease (HD). Methods. 77 patients with NHL (n = 58) or HD (n = 19) underwent a FDG PET scan, a contrast-enhanced CT, and a subsequent digital image fusion during initial staging or followup. 109 examinations of each modality were evaluated and compared to each other. Conventional staging procedures, other imaging techniques, laboratory screening, and follow-up data constituted the reference standard for comparison with image fusion. Sensitivity and specificity were calculated for CT and PET separately. Results. Sensitivity and specificity for detecting malignant lymphoma were 90% and 76% for CT and 94% and 91% for PET, respectively. A lymph node region-based analysis (comprising 14 defined anatomical regions) revealed a sensitivity of 81% and a specificity of 97% for CT and 96% and 99% for FDG PET, respectively. Only three of 109 image fusion findings needed further evaluation (false positive). Conclusion. Digital fusion of PET and CT improves the accuracy of staging, restaging, and therapy monitoring in patients with malignant lymphoma and may reduce the need for invasive diagnostic procedures. PMID:22654631
Lamers, L M
1999-01-01
OBJECTIVE: To evaluate the predictive accuracy of the Diagnostic Cost Group (DCG) model using health survey information. DATA SOURCES/STUDY SETTING: Longitudinal data collected for a sample of members of a Dutch sickness fund. In the Netherlands the sickness funds provide compulsory health insurance coverage for the 60 percent of the population in the lowest income brackets. STUDY DESIGN: A demographic model and DCG capitation models are estimated by means of ordinary least squares, with an individual's annual healthcare expenditures in 1994 as the dependent variable. For subgroups based on health survey information, costs predicted by the models are compared with actual costs. Using stepwise regression procedures a subset of relevant survey variables that could improve the predictive accuracy of the three-year DCG model was identified. Capitation models were extended with these variables. DATA COLLECTION/EXTRACTION METHODS: For the empirical analysis, panel data of sickness fund members were used that contained demographic information, annual healthcare expenditures, and diagnostic information from hospitalizations for each member. In 1993, a mailed health survey was conducted among a random sample of 15,000 persons in the panel data set, with a 70 percent response rate. PRINCIPAL FINDINGS: The predictive accuracy of the demographic model improves when it is extended with diagnostic information from prior hospitalizations (DCGs). A subset of survey variables further improves the predictive accuracy of the DCG capitation models. The predictable profits and losses based on survey information for the DCG models are smaller than for the demographic model. Most persons with predictable losses based on health survey information were not hospitalized in the preceding year. CONCLUSIONS: The use of diagnostic information from prior hospitalizations is a promising option for improving the demographic capitation payment formula. This study suggests that diagnostic information from outpatient utilization is complementary to DCGs in predicting future costs. PMID:10029506
Opmeer, B C; van Doorn, H C; Heintz, A P M; Burger, C W; Bossuyt, P M M; Mol, B W J
2007-01-01
The aim of this study was to evaluate whether the efficiency of the current diagnostic work up following postmenopausal bleeding could be improved by diagnostic strategies that take into account characteristics of the women in addition to the currently recommended transvaginal measurement of endometrial thickness to determine for subsequent histological assessment. Multicenter, prospective cohort study. A university hospital and seven teaching hospitals in the Netherlands. Consecutive women not using hormone replacement therapy, presenting with postmenopausal bleeding. Five hundred and forty women underwent transvaginal sonography, and in case of endometrial thickness (double layer) above 4 mm, subsequent endometrial sampling was performed. Presence of carcinoma was ruled out by the absence of abnormalities in histological specimen or by an uneventful follow up of at least 6 months. Probability of endometrial carcinoma was estimated by multivariable logistic regression models. For each diagnostic strategy, we calculated diagnostic accuracy (area under receiver operating characteristic curve [AUC]), negative predictive value (NPV) and the number of diagnostic procedures. A strategy with transvaginal sonography alone with a fixed threshold incorrectly classified 0.7% of the women as nonmalignant (NPV: 99.3% [98.5-100%]), with 97% sensitivity and 56% specificity. A strategy integrating characteristics of the women with transvaginal sonography could result in less false reassurances (NPV: 99.6% [99.2-100%]), with only marginal decrease in diagnostic procedures, or a minor increase in false reassurances (NPV: 99.0% [98.3-100%]), with a substantial reduction (15-20%) in the procedures. AUCs associated with these strategies could improve from 0.76 (0.73-0.79) for transvaginal sonography alone to 0.90 (0.87-0.93) for the integrated strategy. Taking into account the characteristics of the women could increase the efficiency of the diagnostic work up for postmenopausal bleeding.
Baniya, Ramkaji; Upadhaya, Sunil; Subedi, Subash Chandra; Khan, Jahangir; Sharma, Prabin; Mohammed, Tabrez Shaik; Bachuwa, Ghassan; Jamil, Laith H
2017-12-01
Two novel enteroscopic procedures, balloon enteroscopy and spiral enteroscopy, have revolutionized the diagnostic and therapeutic approach to small-bowel disorders. These disorders that historically required surgical interventions are now investigated and managed nonsurgically. Only a few weakly powered studies have compared the outcomes of spiral enteroscopy and balloon enteroscopy. We conducted a systematic review and meta-analysis to compare the efficacy and safety of these 2 procedures. PubMed, Cochrane Library, Scopus, and clinicaltrials.gov databases were searched for all studies published up to January 12, 2017 comparing the efficacy and safety of balloon enteroscopy (single or double) and spiral enteroscopy. Primary outcomes of interest were diagnostic and therapeutic success rates. Other outcomes included procedure length, depth of maximal insertion (DMI), rate of complete enteroscopy, and adverse events. We calculated Odds ratios (ORs) for categorical variables and mean difference (MD) for continuous variables. The Mantel-Haenszel method was used to analyze the data. Fixed and random effect models were used for <50% heterogeneity and >50% heterogeneity, respectively. Eight studies met the inclusion criteria for this meta-analysis. A total of 615 procedures were analyzed, which included 394 balloon enteroscopy and 221 spiral enteroscopy procedures. There were no significant differences in diagnostic and therapeutic success rates (OR, 1.27; 95% confidence interval [CI], .86-1.88; P = .22; and OR, 1.23; 95% CI, .82-1.84; P = .32, respectively) between the 2 procedures. Similarly, DMI was not significantly different between the 2 groups (MD, 26.29; 95% CI, 20.92-73.49; P = .28). However, the procedure time was significantly shorter for the spiral enteroscopy group compared with the balloon enteroscopy group (MD, 11.26; 95% CI, 2.72-19.79; P = .010). A subgroup analysis comparing double balloon enteroscopy with spiral enteroscopy yielded similar results. Both procedures achieved similar diagnostic and therapeutic outcomes and with similar depth of insertion. Spiral enteroscopy has the benefit of shorter procedural time. Copyright © 2017 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-10-01
... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...
Code of Federal Regulations, 2013 CFR
2013-10-01
... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...
Code of Federal Regulations, 2014 CFR
2014-10-01
... professional and technical components of any diagnostic test or procedure using x-rays, ultrasound...-ray, fluoroscopy, or ultrasound procedures that require the insertion of a needle, catheter, tube, or...
The most common mistakes on dermatoscopy of melanocytic lesions
Kamińska-Winciorek, Grażyna
2015-01-01
Dermatoscopy is a method of in vivo evaluation of the structures within the epidermis and dermis. Currently, it may be the most precise pre-surgical method of diagnosing melanocytic lesions. Diagnostic errors may result in unnecessary removal of benign lesions or what is even worse, they can cause early and very early melanomas to be overlooked. Errors in assessment of dermatoscopy can be divided into those arising from failure to maintain proper test procedures (procedural and technical errors) and knowledge based mistakes related to the lack of sufficient familiarity and experience in dermatoscopy. The article discusses the most common mistakes made by beginner or inexperienced dermatoscopists. PMID:25821425
Zimmerli, Stefan; Bialek, Ralf; Blau, Igor W; Christe, Andreas; Lass-Flörl, Cornelia; Presterl, Elisabeth
2016-08-01
We describe the case of a patient with a T-lymphoblastic lymphoma whose disseminated mucormycosis was diagnosed with delay, and we address the diagnostic and therapeutic decision-making process and review the diagnostic workup of patients with potential IFD. The diagnosis was delayed despite a suggestive radiological presentation of the patient's pulmonary lesion. The uncommon risk profile (T-lymphoblastic lymphoma, short neutropenic phases) wrongly led to a low level of suspicion. The diagnosis was also hampered by the lack of indirect markers for infections caused by Mucorales, the low sensitivity of both fungal culture and panfungal PCR, and the limited availability of species-specific PCR. A high level of suspicion of IFD is needed, and aggressive diagnostic procedures should be promptly initiated even in apparently low-risk patients with uncommon presentations. The extent of the analytical workup should be decided on a case-by-case base. Diagnostic tests such as the galactomannan and β-D-glucan test and/or PCR on biological material followed by sequencing should be chosen according to their availability and after evaluation of their specificity and sensitivity. In high-risk patients, preemptive therapy with a broad-spectrum mould-active antifungal agent should be started before definitive diagnostic findings become available.
Herd diagnosis of low pathogen diarrhoea in growing pigs - a pilot study.
Pedersen, Ken Steen; Johansen, Markku; Angen, Oystein; Jorsal, Sven Erik; Nielsen, Jens Peter; Jensen, Tim K; Guedes, Roberto; Ståhl, Marie; Bækbo, Poul
2014-01-01
The major indication for antibiotic use in Danish pigs is treatment of intestinal diseases post weaning. Clinical decisions on antibiotic batch medication are often based on inspection of diarrhoeic pools on the pen floor. In some of these treated diarrhoea outbreaks, intestinal pathogens can only be demonstrated in a small number of pigs within the treated group (low pathogen diarrhoea). Termination of antibiotic batch medication in herds suffering from such diarrhoea could potentially reduce the consumption of antibiotics in the pig industry. The objective of the present pilot study was to suggest criteria for herd diagnosis of low pathogen diarrhoea in growing pigs. Data previously collected from 20 Danish herds were used to create a case series of clinical diarrhoea outbreaks normally subjected to antibiotic treatment. In the present study, these diarrhoea outbreaks were classified as low pathogen (<15% of the pigs having bacterial intestinal disease) (n =5 outbreaks) or high pathogen (≥15% of the pigs having bacterial intestinal disease) (n =15 outbreaks). Based on the case series, different diagnostic procedures were explored, and criteria for herd diagnosis of low pathogen diarrhoea were suggested. The effect of sampling variation was explored by simulation. The diagnostic procedure with the highest combined herd-level sensitivity and specificity was qPCR testing of a pooled sample containing 20 randomly selected faecal samples. The criteria for a positive test result (high pathogen diarrhoea outbreak) were an average of 1.5 diarrhoeic faecal pools on the floor of each pen in the room under investigation and a pathogenic bacterial load ≥35,000 per gram in the faecal pool tested by qPCR. The bacterial load was the sum of Lawsonia intracellularis, Brachyspira pilosicoli and Escherichia coli F4 and F18 bacteria per gram faeces. The herd-diagnostic performance was (herd-level) diagnostic sensitivity =0.99, diagnostic specificity =0.80, positive predictive value =0.94 and negative predictive value =0.96. The pilot study suggests criteria for herd diagnosis of low pathogen diarrhoea in growing pigs. The suggested criteria should now be evaluated, and the effect of terminating antibiotic batch medication in herds identified as suffering from low pathogen diarrhoea should be explored.
Chiolero, Arnaud; Paccaud, Fred; Aujesky, Drahomir; Santschi, Valérie; Rodondi, Nicolas
2015-01-01
Overdiagnosis is the diagnosis of an abnormality that is not associated with a substantial health hazard and that patients have no benefit to be aware of. It is neither a misdiagnosis (diagnostic error), nor a false positive result (positive test in the absence of a real abnormality). It mainly results from screening, use of increasingly sensitive diagnostic tests, incidental findings on routine examinations, and widening diagnostic criteria to define a condition requiring an intervention. The blurring boundaries between risk and disease, physicians' fear of missing a diagnosis and patients' need for reassurance are further causes of overdiagnosis. Overdiagnosis often implies procedures to confirm or exclude the presence of the condition and is by definition associated with useless treatments and interventions, generating harm and costs without any benefit. Overdiagnosis also diverts healthcare professionals from caring about other health issues. Preventing overdiagnosis requires increasing awareness of healthcare professionals and patients about its occurrence, the avoidance of unnecessary and untargeted diagnostic tests, and the avoidance of screening without demonstrated benefits. Furthermore, accounting systematically for the harms and benefits of screening and diagnostic tests and determining risk factor thresholds based on the expected absolute risk reduction would also help prevent overdiagnosis.
Influence of diagnostic criteria on the interpretation of adrenal vein sampling.
Lethielleux, Gaëlle; Amar, Laurence; Raynaud, Alain; Plouin, Pierre-François; Steichen, Olivier
2015-04-01
Guidelines promote the use of adrenal vein sampling (AVS) to document lateralized aldosterone hypersecretion in primary aldosteronism. However, there are large discrepancies between institutions in the criteria used to interpret its results. This study evaluates the consequences of these differences on the classification and management of patients. The results of all 537 AVS procedures performed between January 2001 and July 2010 in our institution were interpreted with 4 diagnostic criteria used in experienced institutions where AVS is performed without cosyntropin (Brisbane, Padua, Paris, and Turin) and with criteria proposed by a recent consensus statement. AVS procedures were classified as unsuccessful, lateralized, or not lateralized according to each set of criteria. Almost 5× more AVS procedures were classified as unsuccessful with the strictest criteria than with the least strict criteria (18% versus 4%, respectively). Similarly, over 2× more AVS procedures were classified as lateralized with the least stringent criteria than with the most stringent criteria (60% versus 26%, respectively). Multiple samples were available from ≥1 side for 155 AVS procedures. These procedures were classified differently by ≥2 right-left sample pairs in 12% to 20% of cases. Thus, different sets of criteria used to interpret AVS in experienced institutions translate into heterogeneous classifications and hence management decisions, for patients with primary aldosteronism. Defining the most appropriate procedures and diagnostic criteria is needed for AVS to achieve optimal performance and fully justify its status as a gold standard. © 2015 American Heart Association, Inc.
Lancioni, Giulio E; Singh, Nirbhay N; O'Reilly, Mark F; Sigafoos, Jeff; de Tommaso, Marina; Megna, Gianfranco; Bosco, Andrea; Buonocunto, Francesca; Sacco, Valentina; Chiapparino, Claudia
2009-02-01
Detecting signs of learning in persons with a diagnosis of post-coma vegetative state and profound motor disabilities could modify their diagnostic label and provide new hopes. In this study, three adults with such a diagnosis were exposed to learning assessment to search for those signs. PROCEDURE AND DESIGN: The assessment procedure relied on participants' eye-blinking responses and microswitch-based technology. The technology consisted of an electronically regulated optic microswitch mounted on an eyeglasses' frame that the participants wore during the study and an electronic control system connected to stimulus sources. Each participant followed an ABABCB design, in which A represented baseline periods, B intervention periods with stimuli contingent on the responses and C a control condition with stimuli presented non-contingently. The level of responding during the B phases was significantly higher than the levels observed during the A phases as well as the C phase for all participants (i.e. indicating clear signs of learning by them). These findings may have important implications for (a) changing the participants' diagnostic label and offering them new programme opportunities and (b) including learning assessment within the evaluation package used for persons with post-coma profound multiple disabilities.
Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.
Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P
2018-03-01
The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.
The Downside of Diagnostic Imaging
An article about radiation exposure during computed tomography and nuclear imaging procedures and the risk of cancer. Several studies released in 2009 have helped to quantify the risk and the growing use of these diagnostic imaging methods.
Arakawa, H; Nakajima, Y; Kurihara, Y; Niimi, H; Ishikawa, T
1996-07-01
We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.
Automated and unsupervised detection of malarial parasites in microscopic images.
Purwar, Yashasvi; Shah, Sirish L; Clarke, Gwen; Almugairi, Areej; Muehlenbachs, Atis
2011-12-13
Malaria is a serious infectious disease. According to the World Health Organization, it is responsible for nearly one million deaths each year. There are various techniques to diagnose malaria of which manual microscopy is considered to be the gold standard. However due to the number of steps required in manual assessment, this diagnostic method is time consuming (leading to late diagnosis) and prone to human error (leading to erroneous diagnosis), even in experienced hands. The focus of this study is to develop a robust, unsupervised and sensitive malaria screening technique with low material cost and one that has an advantage over other techniques in that it minimizes human reliance and is, therefore, more consistent in applying diagnostic criteria. A method based on digital image processing of Giemsa-stained thin smear image is developed to facilitate the diagnostic process. The diagnosis procedure is divided into two parts; enumeration and identification. The image-based method presented here is designed to automate the process of enumeration and identification; with the main advantage being its ability to carry out the diagnosis in an unsupervised manner and yet have high sensitivity and thus reducing cases of false negatives. The image based method is tested over more than 500 images from two independent laboratories. The aim is to distinguish between positive and negative cases of malaria using thin smear blood slide images. Due to the unsupervised nature of method it requires minimal human intervention thus speeding up the whole process of diagnosis. Overall sensitivity to capture cases of malaria is 100% and specificity ranges from 50-88% for all species of malaria parasites. Image based screening method will speed up the whole process of diagnosis and is more advantageous over laboratory procedures that are prone to errors and where pathological expertise is minimal. Further this method provides a consistent and robust way of generating the parasite clearance curves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...
Code of Federal Regulations, 2012 CFR
2012-10-01
... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...
Code of Federal Regulations, 2014 CFR
2014-10-01
... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...
Cost Utility Analysis of Cervical Therapeutic Medial Branch Blocks in Managing Chronic Neck Pain
Manchikanti, Laxmaiah; Pampati, Vidyasagar; Kaye, Alan D.; Hirsch, Joshua A.
2017-01-01
Background:Controlled diagnostic studies have established the prevalence of cervical facet joint pain to range from 36% to 67% based on the criterion standard of ≥ 80% pain relief. Treatment of cervical facet joint pain has been described with Level II evidence of effectiveness for therapeutic facet joint nerve blocks and radiofrequency neurotomy and with no significant evidence for intraarticular injections. However, there have not been any cost effectiveness or cost utility analysis studies performed in managing chronic neck pain with or without headaches with cervical facet joint interventions. Study Design:Cost utility analysis based on the results of a double-blind, randomized, controlled trial of cervical therapeutic medial branch blocks in managing chronic neck pain. Objectives:To assess cost utility of therapeutic cervical medial branch blocks in managing chronic neck pain. Methods: A randomized trial was conducted in a specialty referral private practice interventional pain management center in the United States. This trial assessed the clinical effectiveness of therapeutic cervical medial branch blocks with or without steroids for an established diagnosis of cervical facet joint pain by means of controlled diagnostic blocks. Cost utility analysis was performed with direct payment data for the procedures for a total of 120 patients over a period of 2 years from this trial based on reimbursement rates of 2016. The payment data provided direct procedural costs without inclusion of drug treatments. An additional 40% was added to procedural costs with multiplication of a factor of 1.67 to provide estimated total costs including direct and indirect costs, based on highly regarded surgical literature. Outcome measures included significant improvement defined as at least a 50% improvement with reduction in pain and disability status with a combined 50% or more reduction in pain in Neck Disability Index (NDI) scores. Results:The results showed direct procedural costs per one-year improvement in quality adjusted life year (QALY) of United States Dollar (USD) of $2,552, and overall costs of USD $4,261. Overall, each patient on average received 5.7 ± 2.2 procedures over a period of 2 years. Average significant improvement per procedure was 15.6 ± 12.3 weeks and average significant improvement in 2 years per patient was 86.0 ± 24.6 weeks. Limitations:The limitations of this cost utility analysis are that data are based on a single center evaluation. Only costs of therapeutic interventional procedures and physician visits were included, with extrapolation of indirect costs. Conclusion:The cost utility analysis of therapeutic cervical medial branch blocks in the treatment of chronic neck pain non-responsive to conservative management demonstrated clinical effectiveness and cost utility at USD $4,261 per one year of QALY. PMID:29200944
Cost Utility Analysis of Cervical Therapeutic Medial Branch Blocks in Managing Chronic Neck Pain.
Manchikanti, Laxmaiah; Pampati, Vidyasagar; Kaye, Alan D; Hirsch, Joshua A
2017-01-01
Background: Controlled diagnostic studies have established the prevalence of cervical facet joint pain to range from 36% to 67% based on the criterion standard of ≥ 80% pain relief. Treatment of cervical facet joint pain has been described with Level II evidence of effectiveness for therapeutic facet joint nerve blocks and radiofrequency neurotomy and with no significant evidence for intraarticular injections. However, there have not been any cost effectiveness or cost utility analysis studies performed in managing chronic neck pain with or without headaches with cervical facet joint interventions. Study Design: Cost utility analysis based on the results of a double-blind, randomized, controlled trial of cervical therapeutic medial branch blocks in managing chronic neck pain. Objectives: To assess cost utility of therapeutic cervical medial branch blocks in managing chronic neck pain. Methods: A randomized trial was conducted in a specialty referral private practice interventional pain management center in the United States. This trial assessed the clinical effectiveness of therapeutic cervical medial branch blocks with or without steroids for an established diagnosis of cervical facet joint pain by means of controlled diagnostic blocks. Cost utility analysis was performed with direct payment data for the procedures for a total of 120 patients over a period of 2 years from this trial based on reimbursement rates of 2016. The payment data provided direct procedural costs without inclusion of drug treatments. An additional 40% was added to procedural costs with multiplication of a factor of 1.67 to provide estimated total costs including direct and indirect costs, based on highly regarded surgical literature. Outcome measures included significant improvement defined as at least a 50% improvement with reduction in pain and disability status with a combined 50% or more reduction in pain in Neck Disability Index (NDI) scores. Results: The results showed direct procedural costs per one-year improvement in quality adjusted life year (QALY) of United States Dollar (USD) of $2,552, and overall costs of USD $4,261. Overall, each patient on average received 5.7 ± 2.2 procedures over a period of 2 years. Average significant improvement per procedure was 15.6 ± 12.3 weeks and average significant improvement in 2 years per patient was 86.0 ± 24.6 weeks. Limitations: The limitations of this cost utility analysis are that data are based on a single center evaluation. Only costs of therapeutic interventional procedures and physician visits were included, with extrapolation of indirect costs. Conclusion: The cost utility analysis of therapeutic cervical medial branch blocks in the treatment of chronic neck pain non-responsive to conservative management demonstrated clinical effectiveness and cost utility at USD $4,261 per one year of QALY.
Boersma, Wim G; Erjavec, Zoran; van der Werf, Tjip S; de Vries-Hosper, Hilly G; Gouw, Annette S H; Manson, Willem L
2007-02-01
Treatment of patients with hematologic malignancies is often complicated by severe respiratory infections. Bronchoscopy is generally to be used as a diagnostic tool in order to find a causative pathogen. In a prospective study the combination of protected specimen brush (PSB) and protected bronchoalveolar lavage (PBAL) was compared with bronchoalveolar lavage (BAL) for evaluated feasibility and diagnostic yield in granulocytopenic patients with hematologic malignancies and pulmonary infiltrates. All specimens from 63 bronchoscopic procedures (35 BAL and 28 PSB-PBAL) were investigated by cytological examination and various microbiological tests. If clinically relevant and feasible, based on the clinical condition and/or the presence of thrombocytopenia, lung tissue samples were obtained. The majority of the 58 included patients were diagnosed as having acute myeloid leukaemia and developed a severe neutropenia (BAL-group: 27 days; PSB-PBAL group: 30 days). Microbiological and cytological examination of 63 bronchoscopic procedures (35 BAL and 28 PSB-PBAL) yielded causative pathogens in 9 (26%) patients of the BAL-group and 8 (29%) patients of the PSB-PBAL group (PSB and PBAL 4 each). Aspergillus fumigatus was the pathogen most frequently (13%) detected. Using all available examinations including the results of autopsy, a presumptive diagnosis was established in 43% of the patients in the BAL group and 57% of those in the PSB-PBAL group; in these cases microbial aetiology was correctly identified in 67% and 57%, respectively. The complication rate was of these procedures were low, and none of the patients experienced serious complications due to the invasive techniques. Our results showed that modern bronchoscopic techniques such as PSB and PBAL did not yield better diagnostic results compared to BAL in granulocytopenic patients with hematologic malignancies and pulmonary infiltrates. In approximately half of the cases a presumptive diagnosis was made by bronchoscopic procedures.
Effect of routine diagnostic imaging for patients with musculoskeletal disorders: A meta-analysis.
Karel, Yasmaine H J M; Verkerk, Karin; Endenburg, Silvio; Metselaar, Sven; Verhagen, Arianne P
2015-10-01
The increasing use of diagnostic imaging has led to high expenditures, unnecessary invasive procedures and/or false-positive diagnoses, without certainty that the patients actually benefit from these imaging procedures. This review explores whether diagnostic imaging leads to better patient-reported outcomes in individuals with musculoskeletal disorders. Databases were searched from inception to September 2013, together with scrutiny of selected bibliographies. Trials were eligible when: 1) a diagnostic imaging procedure was compared with any control group not getting or not receiving the results of imaging; 2) the population included individuals suffering from musculoskeletal disorders, and 3) if patient-reported outcomes were available. Primary outcome measures were pain and function. Secondary outcome measures were satisfaction and quality of life. Subgroup analysis was done for different musculoskeletal complaints and high technological medical imaging (MRI/CT). Eleven trials were eligible. The effects of diagnostic imaging were only evaluated in patients with low back pain (n=7) and knee complaints (n=4). Overall, there was a moderate level of evidence for no benefit of diagnostic imaging on all outcomes compared with controls. A significant but clinically irrelevant effect was found in favor of no (routine) imaging in low back pain patients in terms of pain severity at short [SMD 0.17 (0.04-0.31)] and long-term follow-up [SMD 0.13 (0.02-0.24)], and for overall improvement [RR 1.15 (1.03-1.28)]. Subgroup analysis did not significantly change these results. These results strengthen the available evidence that routine referral to diagnostic imaging by general practitioners for patients with knee and low back pain yields little to no benefit. Copyright © 2015 European Federation of Internal Medicine. Published by Elsevier B.V. All rights reserved.
Maroney, Justin; Khan, Saba; Powell, Wayne; Klein, Lloyd W
2013-01-01
We seek to assess the per-operator volume of diagnostic catheterizations and percutaneous coronary interventions (PCI) among US cardiologists, and its implication for future manpower needs in the catheterization laboratory. The number of annual Medicare PCIs peaked in 2004 and has trended downward since, however the total number of catheterization laboratories nationwide has increased. It is unknown whether these trends have resulted in a dilution of per-operator volumes, and whether the current supply of interventional cardiologists is appropriate to meet future needs. We analyzed the Centers for Medicare and Medicaid Services 2008 Medicare 5% sample file, and extracted the total number of Medicare fee-for-service (Medicare FFS) diagnostic catheterizations and PCIs performed in 2008. We then determined per-physician procedure volumes using National Provider Identifier numbers. There were 1,198,610 Medicare FFS diagnostic catheterizations performed by 11,029 diagnostic cardiologists, and there were 378,372 Medicare FFS PCIs performed by 6,443 interventional cardiologists in 2008. The data reveal a marked difference in the 2008 distribution of diagnostic catheterizations and PCIs among operators. Just over 10% of diagnostic catheterizations were performed by operators performing 40 or fewer Medicare FFS diagnostic catheterizations, contrasted with almost 30% of PCIs performed by operators with 40 of fewer Medicare FFS PCIs. A significant majority of interventional cardiologists (61%) performed 40 or fewer Medicare FFS PCIs in 2008. There is a high percentage of low-volume operators performing PCI, raising questions regarding annual volume recommendations for procedural skill maintenance, and the future manpower requirements in the catheterization laboratory. Copyright © 2012 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.
This Technology Learning Activity (TLA) on exploring diagnostic care careers for Grade 9 is designed for use in eight class periods. It gives students experience in using standard health care equipment to perform basic diagnostic procedures. This teacher's edition begins with an overview of technology education. The second section describes…
ERIC Educational Resources Information Center
Alderson, J. Charles; Brunfaut, Tineke; Harding, Luke
2015-01-01
Diagnostic language assessment has received increased research interest in recent years, with particular attention on methods through which diagnostic information can be gleaned from standardized proficiency tests. However, diagnostic procedures in the broader sense have been inadequately theorized to date, with the result that there is still…
School-based assessment of attention deficit-hyperactivity disorder.
Atkins, M S; Pelham, W E
1991-04-01
Schools are uniquely situated to provide information relevant to the assessment and treatment of Attention Deficit-Hyperactivity Disorder (ADHD) across a variety of tasks, settings, and observers. The importance of the school setting to the assessment and treatment of ADHD has resulted in the development of numerous measures appropriate for such assessment, but few guidelines for their use. The purpose of this article is to describe school-based assessment procedures and their relationship to ADHD. These procedures include teacher rating measures, direct observations in classrooms and on playgrounds, peer rating and sociometric measures, and permanent product measures such as academic performance. It is recommended that school-based assessment of ADHD involve the concurrent use of multiple measures to assess adequately the wide variety of symptoms associated with this disorder. It is further recommended that assessment serve the purpose of determining treatment efficacy to avoid unwarranted preoccupation with diagnostic issues that are as yet unresolved. The components of a comprehensive school-based assessment of ADHD are described, and their relationship to school-based treatment is discussed.
Measures of Agreement Between Many Raters for Ordinal Classifications
Nelson, Kerrie P.; Edwards, Don
2015-01-01
Screening and diagnostic procedures often require a physician's subjective interpretation of a patient's test result using an ordered categorical scale to define the patient's disease severity. Due to wide variability observed between physicians’ ratings, many large-scale studies have been conducted to quantify agreement between multiple experts’ ordinal classifications in common diagnostic procedures such as mammography. However, very few statistical approaches are available to assess agreement in these large-scale settings. Existing summary measures of agreement rely on extensions of Cohen's kappa [1 - 5]. These are prone to prevalence and marginal distribution issues, become increasingly complex for more than three experts or are not easily implemented. Here we propose a model-based approach to assess agreement in large-scale studies based upon a framework of ordinal generalized linear mixed models. A summary measure of agreement is proposed for multiple experts assessing the same sample of patients’ test results according to an ordered categorical scale. This measure avoids some of the key flaws associated with Cohen's kappa and its extensions. Simulation studies are conducted to demonstrate the validity of the approach with comparison to commonly used agreement measures. The proposed methods are easily implemented using the software package R and are applied to two large-scale cancer agreement studies. PMID:26095449
Cannon, W Dilworth; Garrett, William E; Hunter, Robert E; Sweeney, Howard J; Eckhoff, Donald G; Nicandri, Gregg T; Hutchinson, Mark R; Johnson, Donald D; Bisson, Leslie J; Bedi, Asheesh; Hill, James A; Koh, Jason L; Reinig, Karl D
2014-11-05
There is a paucity of articles in the surgical literature demonstrating transfer validity (transfer of training). The purpose of this study was to assess whether skills learned on the ArthroSim virtual-reality arthroscopic knee simulator transferred to greater skill levels in the operating room. Postgraduate year-3 orthopaedic residents were randomized into simulator-trained and control groups at seven academic institutions. The experimental group trained on the simulator, performing a knee diagnostic arthroscopy procedure to a predetermined proficiency level based on the average proficiency of five community-based orthopaedic surgeons performing the same procedure on the simulator. The residents in the control group continued their institution-specific orthopaedic education and training. Both groups then performed a diagnostic knee arthroscopy procedure on a live patient. Video recordings of the arthroscopic surgery were analyzed by five pairs of expert arthroscopic surgeons blinded to the identity of the residents. A proprietary global rating scale and a procedural checklist, which included visualization and probing scales, were used for rating. Forty-eight (89%) of the fifty-four postgraduate year-3 residents from seven academic institutions completed the study. The simulator-trained group averaged eleven hours of training on the simulator to reach proficiency. The simulator-trained group performed significantly better when rated according to our procedural checklist (p = 0.031), including probing skills (p = 0.016) but not visualization skills (p = 0.34), compared with the control group. The procedural checklist weighted probing skills double the weight of visualization skills. The global rating scale failed to reach significance (p = 0.061) because of one extreme outlier. The duration of the procedure was not significant. This lack of a significant difference seemed to be related to the fact that residents in the control group were less thorough, which shortened their time to completion of the arthroscopic procedure. We have demonstrated transfer validity (transfer of training) that residents trained to proficiency on a high-fidelity realistic virtual-reality arthroscopic knee simulator showed a greater skill level in the operating room compared with the control group. We believe that the results of our study will stimulate residency program directors to incorporate surgical simulation into the core curriculum of their residency programs. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Reuter, Katrin; Raugust, Simone; Bengel, Jürgen; Härter, Martin
2004-12-01
In order to obtain references for adequate diagnostic procedures of depressive syndromes in cancer patients, the present study analyzes first the prevalence of somatic, emotional, and cognitive symptoms of depression. In a second part, the ability of diagnostic procedures to discriminate between patients with and without comorbid affective disorder is investigated. From a cross-sectional survey investigating comorbid mental disorders in cancer patients with standardized clinical assessment, a subsample of 71 patients with current affective disorders and depressive symptoms according to the Diagnostic and Statistic Manual of Mental Disorders, 4th edition (DSM-IV) were analyzed. In addition to patients' symptom patterns, a discriminant analysis including all depressive symptoms was conducted. Cognitive symptoms are less prevalent in cancer patients than somatic and emotional symptoms. Loss of interest discriminated best between patients with and without diagnosis of comorbid affective disorder. Additionally, decreased energy and fatigue proved to have discriminatory value. Cognitive symptoms should receive special attention in diagnostic procedures for affective disorders in cancer patients. In spite of possible symptom overlap with the cancer disease and its treatment, fatigue proves to be a useful criteria for diagnosis of depression.
Frederick, R I
2000-01-01
Mixed group validation (MGV) is offered as an alternative to criterion group validation (CGV) to estimate the true positive and false positive rates of tests and other diagnostic signs. CGV requires perfect confidence about each research participant's status with respect to the presence or absence of pathology. MGV determines diagnostic efficiencies based on group data; knowing an individual's status with respect to pathology is not required. MGV can use relatively weak indicators to validate better diagnostic signs, whereas CGV requires perfect diagnostic signs to avoid error in computing true positive and false positive rates. The process of MGV is explained, and a computer simulation demonstrates the soundness of the procedure. MGV of the Rey 15-Item Memory Test (Rey, 1958) for 723 pre-trial criminal defendants resulted in higher estimates of true positive rates and lower estimates of false positive rates as compared with prior research conducted with CGV. The author demonstrates how MGV addresses all the criticisms Rogers (1997b) outlined for differential prevalence designs in malingering detection research. Copyright 2000 John Wiley & Sons, Ltd.
Radiological Examinations in Pediatric Age.
Siciliano, R
2017-01-01
Diagnostic radiology imaging is an essential tool for adequate clinical investigation of pathological processes and the drafting of a personalized therapy plan. However, in recent years, there has been a substantial increase of requests, mainly due to technological advances but also to social and cultural reasons, not always based on the principle of the diagnostic justification. The progress of recent years in the field of diagnostic radiology has made available to the physician a variety of sophisticated radiological examinations, which are not always used rationally and appropriately. The theme is of paramount importance, particularly in childhood or adolescence, characterized by elevated radiosensitivity (high cell turnover) and longer life expectancy; therefore, children exposed to ionizing radiation are theoretically subject to a higher risk of carcinogenesis compared to the general population. For these reasons the young patients should have greater protection and examinations must respect stringent appropriateness criteria. Far from underestimating the important diagnostic and therapeutic benefits that these procedures provide, the use of ionizing radiations must minimize the radiation-related risk in accordance with the ALARA principle (As Low As Reasonably Achievable), key principle of modern radiation protection.
Improved Temperature Diagnostic for Non-Neutral Plasmas with Single-Electron Resolution
NASA Astrophysics Data System (ADS)
Shanman, Sabrina; Evans, Lenny; Fajans, Joel; Hunter, Eric; Nelson, Cheyenne; Sierra, Carlos; Wurtele, Jonathan
2016-10-01
Plasma temperature diagnostics in a Penning-Malmberg trap are essential for reliably obtaining cold, non-neutral plasmas. We have developed a setup for detecting the initial electrons that escape from a trapped pure electron plasma as the confining electrode potential is slowly reduced. The setup minimizes external noise by using a silicon photomultiplier to capture light emitted from an MCP-amplified phosphor screen. To take advantage of this enhanced resolution, we have developed a new plasma temperature diagnostic analysis procedure which takes discrete electron arrival times as input. We have run extensive simulations comparing this new discrete algorithm to our existing exponential fitting algorithm. These simulations are used to explore the behavior of these two temperature diagnostic procedures at low N and at high electronic noise. This work was supported by the DOE DE-FG02-06ER54904, and the NSF 1500538-PHY.
Optimization of a bolometer detector for ITER based on Pt absorber on SiN membrane.
Meister, H; Eich, T; Endstrasser, N; Giannone, L; Kannamüller, M; Kling, A; Koll, J; Trautmann, T; Detemple, P; Schmitt, S
2010-10-01
Any plasma diagnostic in ITER must be able to operate at temperatures in excess of 200 °C and neutron loads corresponding to 0.1 dpa over its lifetime. To achieve this aim for the bolometer diagnostic, a miniaturized metal resistor bolometer detector based on Pt absorbers galvanically deposited on SiN membranes is being developed. The first two generations of detectors featured up to 4.5 μm thick absorbers. Results from laboratory tests are presented characterizing the dependence of their calibration constants under thermal loads up to 450 °C. Several detectors have been tested in ASDEX Upgrade providing reliable data but also pointing out the need for further optimization. A laser trimming procedure has been implemented to reduce the mismatch in meander resistances below 1% for one detector and the thermal drifts from this mismatch.
Optimization of a bolometer detector for ITER based on Pt absorber on SiN membranea)
NASA Astrophysics Data System (ADS)
Meister, H.; Eich, T.; Endstrasser, N.; Giannone, L.; Kannamüller, M.; Kling, A.; Koll, J.; Trautmann, T.; ASDEX Upgrade Team; Detemple, P.; Schmitt, S.
2010-10-01
Any plasma diagnostic in ITER must be able to operate at temperatures in excess of 200 °C and neutron loads corresponding to 0.1 dpa over its lifetime. To achieve this aim for the bolometer diagnostic, a miniaturized metal resistor bolometer detector based on Pt absorbers galvanically deposited on SiN membranes is being developed. The first two generations of detectors featured up to 4.5 μm thick absorbers. Results from laboratory tests are presented characterizing the dependence of their calibration constants under thermal loads up to 450 °C. Several detectors have been tested in ASDEX Upgrade providing reliable data but also pointing out the need for further optimization. A laser trimming procedure has been implemented to reduce the mismatch in meander resistances below 1% for one detector and the thermal drifts from this mismatch.
Surgical Procedures. Second Edition. Teacher Edition.
ERIC Educational Resources Information Center
Baker, Beverly; And Others
This teacher's guide contains 13 units of instruction for a course that will prepare students with the entry-level competencies needed by a surgical technologist. The course covers the following topics: introduction to surgical procedures; diagnostic procedures; general surgery; gastrointestinal surgery; obstetrics and gynecological surgery;…
Cozzi, Giorgio; Norbedo, Stefania; Barbi, Egidio
2017-04-01
Sedation is often required for children undergoing diagnostic procedures. Chloral hydrate has been one of the sedative drugs most used in children over the last 3 decades, with supporting evidence for its efficacy and safety. Recently, chloral hydrate was banned in Italy and France, in consideration of evidence of its carcinogenicity and genotoxicity. Dexmedetomidine is a sedative with unique properties that has been increasingly used for procedural sedation in children. Several studies demonstrated its efficacy and safety for sedation in non-painful diagnostic procedures. Dexmedetomidine's impact on respiratory drive and airway patency and tone is much less when compared to the majority of other sedative agents. Administration via the intranasal route allows satisfactory procedural success rates. Studies that specifically compared intranasal dexmedetomidine and chloral hydrate for children undergoing non-painful procedures showed that dexmedetomidine was as effective as and safer than chloral hydrate. For these reasons, we suggest that intranasal dexmedetomidine could be a suitable alternative to chloral hydrate.
Microfluidic Separation of Circulating Tumor Cells Based on Size and Deformability.
Park, Emily S; Duffy, Simon P; Ma, Hongshen
2017-01-01
Circulating tumor cells (CTCs) have been implicated as the seeds of cancer metastasis and therefore have the potential to provide significant prognostic and diagnostic values. Here, we describe a procedure for separating CTCs from whole blood based on size and deformability using the microfluidic ratchet device. This device leverages the ratcheting motion of single cells created as they are deformed through funnel-shaped constrictions using oscillatory flow in order to divert cells based on differences in size and deformability. Subsequent methods for CTC identification and enumeration using immunofluorescence after separation are also described.
A Model-Free Diagnostic for Single-Peakedness of Item Responses Using Ordered Conditional Means.
Polak, Marike; de Rooij, Mark; Heiser, Willem J
2012-09-01
In this article we propose a model-free diagnostic for single-peakedness (unimodality) of item responses. Presuming a unidimensional unfolding scale and a given item ordering, we approximate item response functions of all items based on ordered conditional means (OCM). The proposed OCM methodology is based on Thurstone & Chave's (1929) criterion of irrelevance, which is a graphical, exploratory method for evaluating the "relevance" of dichotomous attitude items. We generalized this criterion to graded response items and quantified the relevance by fitting a unimodal smoother. The resulting goodness-of-fit was used to determine item fit and aggregated scale fit. Based on a simulation procedure, cutoff values were proposed for the measures of item fit. These cutoff values showed high power rates and acceptable Type I error rates. We present 2 applications of the OCM method. First, we apply the OCM method to personality data from the Developmental Profile; second, we analyze attitude data collected by Roberts and Laughlin (1996) concerning opinions of capital punishment.
[Management accounting in hospital setting].
Brzović, Z; Richter, D; Simunić, S; Bozić, R; Hadjina, N; Piacun, D; Harcet, B
1998-12-01
The periodic income and expenditure accounts produced at the hospital and departmental level enable successful short term management, but, in the long run do not help remove tensions between health care demand and limited resources, nor do they enable optimal medical planning within the limited financial resources. We are trying to estabilish disease category costs based on case mixing according to diagnostic categories (diagnosis related groups, DRG, or health care resource groups, HRG) and calculation of hospital standard product costs, e.g., radiology cost, preoperative nursing cost etc. The average DRG cost is composed of standard product costs plus any costs specific to a diagnostic category. As an example, current costing procedure for hip artheroplasty in the University Hospital Center Zagreb is compared to the management accounting approach based on British Health Care Resource experience. The knowledge of disease category costs based on management accounting requirements facilitates the implementation of medical programs within the given financial resources and devolves managerial responsibility closer to the clinical level where medical decisions take place.
Estimation of the diagnostic threshold accounting for decision costs and sampling uncertainty.
Skaltsa, Konstantina; Jover, Lluís; Carrasco, Josep Lluís
2010-10-01
Medical diagnostic tests are used to classify subjects as non-diseased or diseased. The classification rule usually consists of classifying subjects using the values of a continuous marker that is dichotomised by means of a threshold. Here, the optimum threshold estimate is found by minimising a cost function that accounts for both decision costs and sampling uncertainty. The cost function is optimised either analytically in a normal distribution setting or empirically in a free-distribution setting when the underlying probability distributions of diseased and non-diseased subjects are unknown. Inference of the threshold estimates is based on approximate analytically standard errors and bootstrap-based approaches. The performance of the proposed methodology is assessed by means of a simulation study, and the sample size required for a given confidence interval precision and sample size ratio is also calculated. Finally, a case example based on previously published data concerning the diagnosis of Alzheimer's patients is provided in order to illustrate the procedure.
Design and development of a fiber optic TDI CCD-based slot-scan digital mammography system
NASA Astrophysics Data System (ADS)
Toker, Emre; Piccaro, Michele F.
1993-12-01
We previously reported on the development, design, and clinical evaluation of a CCD-based, high performance, filmless imaging system for stereotactic needle biopsy procedures in mammography. The MammoVision system has a limited imaging area of 50 mm X 50 mm, since it is designed specifically for breast biopsy applications. We are currently developing a new filmless imaging system designed to cover the 18 cm X 24 cm imaging area required for screening and diagnostic mammography. The diagnostic mammography system is based on four 1100 X 330 pixel format, full-frame, scientific grade, front illuminated, MPP mode CCDs, with 24 micrometers X 24 micrometers square pixels Each CCD is coupled to an x-ray intensifying screen via a 1.7:1 fiber optic reducer. The detector assembly (180 mm long and 13.5 mm wide) is scanned across the patient's breast synchronously with the x-ray source, with the CCDs operated in time-delay integration (TDI) mode. The total scan time is 4.0 seconds.
Smith, Toby O; Drew, Benjamin T; Toms, Andoni P
2012-07-01
Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have gained increasing favour in the assessment of patients with suspected glenoid labral injuries. The purpose of this study was to determine the diagnostic accuracy of MRI or MRA in the detection of gleniod labral lesions. A systematic review was undertaken of the electronic databases Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, AMED and CINAHL, in addition to a search of unpublished literature databases. All studies which compared the ability of MRI or MRA (index test) to assess gleniod labral tears or lesions, when verified with a surgical procedure (arthroscopy or open surgery-reference test) were included. Data extraction and methodological appraisal using the QUADAS tool were both conducted by two reviewers independently. Data were analysed through a summary receiver operator characteristic curve and pooled sensitivity and specificity analysis were calculated with 95% confidence intervals. Sixty studies including 4,667 shoulders from 4,574 patients were reviewed. There appeared slightly greater diagnostic test accuracy for MRA over MRI for the detection of overall gleniod labral lesions (MRA-sensitivity 88%, specificity 93% vs. MRI sensitivity 76% vs. specificity 87%). Methodologically, studies recruited and identified their samples appropriately and clearly defined the radiological procedures. In general, it was not clearly defined why patients were lost during the study, and studies were poor at recording whether the same clinical data were available to the radiologist interpreting the MRI or MRA as would be available in clinical practice. Most studies did not state whether the surgeon interpreting the arthroscopic procedure was blinded to the results of the MR or MRA imaging. Based on the available literature, overall MRA appeared marginally superior to MRI for the detection of glenohumeral labral lesions. Level 2a.
Lukanova, M; Miteva, I; Gorgioski, S; Popov, I
2008-01-01
To determine the trend in application of the basic therapeutical procedures in the most common gynaecological diseases combined or not with chronic pelvic pain /CPP/. In the prospective study conducted in the Gynaecological Clinic at the Department of Obstetrics and Gynaecology, MU-Pleven in the period 01.03.2004-01.07.2007, 1356 women with leiomyomatosis /L/, endometriosis /E/, adenomyosis /A/, pelvic congestion syndrome /PCS/, Allen-Masters syndrome /AMS/, pelvic inflammatory disease /PID/ and adhaesion syndrome /AS/, were included in it. They were grouped according to their age, type of disease, presence of CPP, type of therapeutical procedure and histological verification of the condition. For the purpose of the study the following methods were used: documentary method, R-AFS classification of E, inquiry method-by a questionnaire /form/, based on instruments for pain assessment, accepted worldwide. The highest frequency was determined for L, E and A, and AS. In the majority of the total number of consecutively admitted patients with those diseases an operative intervention was done, and almost one-sixth of women underwent conservative treatment. The same trend was observed in patients with chronic pain symptomatic, regarding their operative and conservative management. Histological verification of the condition was closely related with etiological reason and diagnostic approach. A balance between conservative and operative treatment should be set in the basis of therapeutical management, consistent with modern diagnostic procedures. Determination of the trend in treatment of women with CPP will lead to falling off of indiscriminate application of operative methods prior to exact diagnostic specification and setting of multidisciplinary approach. That will serve as a background for the future conduct to that group of patients.
On the qi deficiency in traditional Chinese medicine.
Chiang, Hui-Chu; Chang, Hen-Hong; Huang, Po-Yu; Hsu, Mutsu
2014-09-01
Qi deficiency (QD), one of the most common disorders in Traditional Chinese medicine (TCM), is relevant to many disorders in obstetrics and gynecology. This study aimed to identify the common processes and criteria for diagnosing QD among contemporary proficient TCM practitioners. Steps of decision tree analysis and modified Delphi method were merged together into four-round postal questionnaires to collect qualitative and quantitative data. Open-ended questions and content analysis were used to explore the proficient TCM practitioners' cognitive activities used for diagnosis. The statements obtained from the qualitative responses were used to develop the items for subsequent questionnaires. Based on the TCM practitioners' responses, the diagnostic processes and criteria for making diagnosis were generated. Twenty-eight out of the 30 participants completed all four questionnaires from June 2007 to January 2010. The 11 diagnostic procedures identified in the returned first round of questionnaires were used as the alternatives to select and rank for all the steps to diagnose QD. After three more rounds of postal surveys, an algorithm with a five-stage diagnostic process as well as sets of decision criteria were identified. Although the priorities of procedures and descriptions of reasoning were varied, the content revealed the major themes in the model. The criteria to differentiate signs and symptoms (S/S) included five principles for correlating S/S with QD, and 17 S/S should be differentiated carefully. The results demonstrate that the TCM practitioners precisely diagnosed QD using a number of specific procedures and criteria that could be used as a reference to understand women complaining of S/S that could be similar to QD. Copyright © 2014. Published by Elsevier B.V.
Schmitter, Marc; Kress, Bodo; Leckel, Michael; Henschel, Volkmar; Ohlmann, Brigitte; Rammelsberg, Peter
2008-06-01
This hypothesis-generating study was performed to determine which items in the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) and additional diagnostic tests have the best predictive accuracy for joint-related diagnoses. One hundred forty-nine TMD patients and 43 symptom-free subjects were examined in clinical examinations and with magnetic resonance imaging (MRI). The importance of each variable of the clinical examination for correct joint-related diagnosis was assessed by using MRI diagnoses. For this purpose, "random forest" statistical software (based on classification trees) was used. Maximum unassisted jaw opening, maximum assisted jaw opening, history of locked jaw, joint sound with and without compression, joint pain, facial pain, pain on palpation of the lateral pterygoid area, and overjet proved suitable for distinguishing between subtypes of joint-related TMD. Measurement of excursion, protrusion, and midline deviation were less important. The validity of clinical TMD examination procedures can be enhanced by using the 16 variables of greatest importance identified in this study. In addition to other variables, maximum unassisted and assisted opening and a history of locked jaw were important when assessing the status of the TMJ.
NASA Astrophysics Data System (ADS)
Hunter, Kendall; Zhang, Yanhang; Lanning, Craig
2005-11-01
Insight into the progression of pulmonary hypertension may be obtained from thorough study of vascular flow during reactivity testing, an invasive diagnostic procedure which can dramatically alter vascular hemodynamics. Diagnostic imaging methods, however, are limited in their ability to provide extensive data. Here we present detailed flow and wall deformation results from simulations of pulmonary arteries undergoing this procedure. Patient-specific 3-D geometric reconstructions of the first four branches of the pulmonary vasculature were obtained clinically and meshed for use with computational software. Transient simulations in normal and reactive states were obtained from four such models were completed with patient-specific velocity inlet conditions and flow impedance exit conditions. A microstructurally based orthotropic hyperelastic model that simulates pulmonary artery mechanics under normotensive and hypoxic hypertensive conditions treated wall constitutive changes due to pressure reactivity and arterial remodeling. Pressure gradients, velocity fields, arterial deformation, and complete topography of shear stress were obtained. These models provide richer detail of hemodynamics than can be obtained from current imaging techniques, and should allow maximum characterization of vascular function in the clinical situation.
[Evaluative study of medical-care costs in primary care].
Brotons Cuixart, Carlos; Moral Peláez, Irene; Pitarch Salgado, Marc; Sellarès Sallas, Jaume; Bohigas Santasusagna, Lluís; da Pena Alvarez, José Manuel
2007-09-01
To estimate the real costs of medical care by diagnostic groups at a primary care centre. Descriptive, retrospective study, based on the review of computerized medical records. Urban primary care centre (PCC). All patients who attended the PCC during 2005. Mean medical care cost per visit in euros, broken down for health professionals, diagnostic procedures and drugs costs, and stratified by diagnostic groups. The most frequent visits were for pulmonary, locomotor, cardiovascular, and gastro-intestinal conditions. The mean number of visits per patient attended was 8.7 (SD, 9.4); and per patient registered at the centre, 5.9 (8.7). The highest costs were for cardiovascular (18.96%; 95% CI, 18.93%-18.99%), locomotor (11.21%; 95% CI, 11.18%-11.23%), psychological (10.69%, 95% CI, 10.66%-10.71%), pulmonary (10.20%; 95% CI, 10.17%-10.22%) and endocrinal-nutritional (9.61%; 95% CI, 9.58%-9.63%) problems. Drugs expenditure accounted for 65% of the total cost; visits to health professionals, for 33%; and procedures, for 2%. Overall cost per inhabitant was 239.1 (493.6) euros, and per patient attended was 349.5 (563.5). Cardiovascular disease conditions are much the most costly ones in terms of overall medical cost. Psychological conditions are located in second place in terms of pharmaceutical cost; and in third place, in terms of overall medical-care cost.
[Pediatric radiological diagnostics in suspected child abuse].
Erfurt, C; Hahn, G; Roesner, D; Schmidt, U
2009-10-01
Advanced and specialized radiological diagnostics are essential in the case of clinical suspicion of pediatric injuries to the head, thorax, abdomen, and extremities when there is no case history or when "battered child syndrome" is assumed on the basis of inadequate trauma. In particular, the aim of this sophisticated diagnostic procedure is the detection of lesions of the central nervous system (CNS) in order to initiate prompt medical treatment. If diagnostic imaging shows typical findings of child abuse, accurate documented evidence of the diagnostic results is required to prevent further endangerment of the child's welfare.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schultz, C; Dixon, S
Purpose: To evaluate whether one small systematic reduction in fluoroscopy frame rate has a significant effect on the total air kerma and/or dose area product for diagnostic and interventional cardiac catheterization procedures. Methods: The default fluoroscopy frame rate (FFR) was lowered from 15 to 10 fps in 5 Siemens™ Axiom Artis cardiac catheterization labs (CCL) on July 1, 2013. A total of 7212 consecutive diagnostic and interventional CCL procedures were divided into two study groups: 3602 procedures from 10/1/12 –6/30/13 with FFR of 15 fps; and 3610 procedures 7/1/13 – 3/31/14 at 10 fps. For each procedure, total air kermamore » (TAK), fluoroscopy skin dose (FSD), total/fluoroscopy dose area products (TAD, FAD), and total fluoroscopy time (FT) were recorded. Patient specific data collected for each procedure included: BSA, sex, height, weight, interventional versus diagnostic; and elective versus emergent. Results: For pre to post change in FFR, each categorical variable was compared using Pearson’s Chi-square test, Odds ratios and 95% confidence intervals. No statistically significant difference in BSA, height, weight, number of interventional versus diagnostic, elective versus emergent procedures was found between the two study groups. Decreasing the default FFR from 15 fps to 10 fps in the two study groups significantly reduced TAK from 1305 to 1061 mGy (p<0.0001), FSD from 627 to 454 mGy (p<0.0001), TAD from 8681 to 6991 uGy × m{sup 2}(p<0.0001), and FAD from 4493 to 3297 uGy × m{sup 2}(p<0.0001). No statistically significant difference in FT was noted. Clinical image quality was not analyzed, and reports of noticeable effects were minimal. From July 1, 2013 to date, the default FFR has remained 10 fps. Conclusion: Reducing the FFR from 15 to 10 fps significantly reduced total air kerma and dose area product which may decrease risk for potential radiation-induced skin injuries and improve patient outcomes.« less
Resource utilization in lung cancer diagnostic procedures: Current use and budget consequences.
Brinkhof, Sander; Groen, Harry J M; Siesling, Sabine S; IJzerman, Maarten J
2017-01-01
The main objective of this study is to determine the current use of lung cancer diagnostic procedures in two large hospitals in the Netherlands, to explore deviations in guideline adherence between the hospitals, and to estimate the budget impact of the diagnostic work-up as well as the over- and underutilization. A state transition model for the diagnostic pathway for lung cancer patients was developed using existing clinical practice guidelines (CPG) combined with a systematic literature. In addition to the CPGs depicting current practice, diagnostic utilization was gathered in two large hospitals representing an academic tertiary care hospital and a large regional teaching hospital for patients, who were selected from the Netherlands cancer registry. The total population consisted of 376 patients with lung cancer. Not in all cases the guideline was followed, for instance in the usage of MR brain with stage III lung cancer patients (n = 70). The state-transition model predicts an average budget impact for the diagnostic pathway per patient estimated of € 2496 in the academic tertiary care hospital and € 2191 in the large regional teaching hospital. The adherence to the CPG's differed between hospitals, which questions the adherence to CPG's in general. Adherence to CPG's could lead to less costs in the diagnostic pathway for lung cancer patients.
Biosafety principles and practices for the veterinary diagnostic laboratory.
Kozlovac, Joseph; Schmitt, Beverly
2015-01-01
Good biosafety and biocontainment programs and practices are critical components of the successful operation of any veterinary diagnostic laboratory. In this chapter we provide information and guidance on critical biosafety management program elements, facility requirements, protective equipment, and procedures necessary to ensure that the laboratory worker and the environment are adequately protected in the challenging work environment of the veterinary diagnostic laboratory in general and provide specific guidance for those laboratories employing molecular diagnostic techniques.
Evaluating Utility in Diagnostic Decision Making.
ERIC Educational Resources Information Center
Harber, Jean R.
1981-01-01
The utility of the procedures special educators apply in making decisions about the identification of handicapped individuals has not been thoroughly studied. The paper examines the utility of diagnostic decision making from the perspective of receiver operating curve analysis. (Author)
Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
2011-01-01
Background: New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. Methods: We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. Results: We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). Conclusions: To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further investigate other determinants of diagnostic yield. PMID:21659432
Kim, In-Cheol; Hur, Seung-Ho; Park, Nam-Hee; Jun, Dong-Hwan; Cho, Yun-Kyeong; Nam, Chang-Wook; Kim, Hyungseop; Han, Seong-Wook; Choi, Sae-Young; Kim, Yoon-Nyun; Kim, Kwon-Bae
2011-04-14
Coronary angiography (CAG) is an invasive diagnostic procedure, which could lead to procedure related complications. One of the well known post-procedural complications is cerebral embolic infarction with or without symptoms. Silent embolic cerebral infarction (SECI) has clinical significance because it can progress to a decline in cognitive function and increase the risk of dementia in the long term. The aim of this study was to detect the incidence and predictors of SECI after diagnostic CAG using diffusion-weighted magnetic resonance imaging (DW-MRI). A total of 197 patients with coronary artery disease who underwent DW-MRI for evaluation of intracranial vasculopathy before coronary artery bypass graft surgery were retrospectively enrolled in the present study. DW-MRI was performed within 48 h after diagnostic CAG. SECI was diagnosed as presence of focal bright high signal intensity in DW-MRI. Patients were divided into groups according to presence/absence of SECI (+ SECI vs. - SECI, respectively). The clinical and angiographic characteristics were analyzed and independent predictors were evaluated. Of the 197 patients, SECI occurred in 20 patients (10.2%) after diagnostic CAG. Age, female gender, frequency of underlying atrial fibrillation, extent of coronary disease, and fluoroscopic time during diagnostic CAG were not different between the + SECI and - SECI groups. Left ventricular ejection fraction was significantly lower in the + SECI group than in the - SECI group (45.9 ± 8.5% vs. 51.4 ± 13.1%, p=0.014) and performance rate of internal mammary artery (IMA) angiography was significantly higher in the + SECI group compared with the - SECI group (85% vs. 37.2%, p<0.001). By multivariate analysis, performing IMA angiography was the only predictor of SECI (OR=14.642; 95% CI=3.201 to 66.980, p=0.001). The incidence of SECI after diagnostic CAG was not infrequent. Diagnostic CAG with IMA angiography may increase the risk of SECI. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
PROcess Based Diagnostics PROBE
NASA Technical Reports Server (NTRS)
Clune, T.; Schmidt, G.; Kuo, K.; Bauer, M.; Oloso, H.
2013-01-01
Many of the aspects of the climate system that are of the greatest interest (e.g., the sensitivity of the system to external forcings) are emergent properties that arise via the complex interplay between disparate processes. This is also true for climate models most diagnostics are not a function of an isolated portion of source code, but rather are affected by multiple components and procedures. Thus any model-observation mismatch is hard to attribute to any specific piece of code or imperfection in a specific model assumption. An alternative approach is to identify diagnostics that are more closely tied to specific processes -- implying that if a mismatch is found, it should be much easier to identify and address specific algorithmic choices that will improve the simulation. However, this approach requires looking at model output and observational data in a more sophisticated way than the more traditional production of monthly or annual mean quantities. The data must instead be filtered in time and space for examples of the specific process being targeted.We are developing a data analysis environment called PROcess-Based Explorer (PROBE) that seeks to enable efficient and systematic computation of process-based diagnostics on very large sets of data. In this environment, investigators can define arbitrarily complex filters and then seamlessly perform computations in parallel on the filtered output from their model. The same analysis can be performed on additional related data sets (e.g., reanalyses) thereby enabling routine comparisons between model and observational data. PROBE also incorporates workflow technology to automatically update computed diagnostics for subsequent executions of a model. In this presentation, we will discuss the design and current status of PROBE as well as share results from some preliminary use cases.
Pelaccia, Thierry; Tardif, Jacques; Triby, Emmanuel; Ammirati, Christine; Bertrand, Catherine; Dory, Valérie; Charlin, Bernard
2014-12-01
The ability to make a diagnosis is a crucial skill in emergency medicine. Little is known about the way emergency physicians reach a diagnosis. This study aims to identify how and when, during the initial patient examination, emergency physicians generate and evaluate diagnostic hypotheses. We carried out a qualitative research project based on semistructured interviews with emergency physicians. The interviews concerned management of an emergency situation during routine medical practice. They were associated with viewing the video recording of emergency situations filmed in an "own-point-of-view" perspective. The emergency physicians generated an average of 5 diagnostic hypotheses. Most of these hypotheses were generated before meeting the patient or within the first 5 minutes of the meeting. The hypotheses were then rank ordered within the context of a verification procedure based on identifying key information. These tasks were usually accomplished without conscious effort. No hypothesis was completely confirmed or refuted until the results of investigations were available. The generation and rank ordering of diagnostic hypotheses is based on the activation of cognitive processes, enabling expert emergency physicians to process environmental information and link it to past experiences. The physicians seemed to strive to avoid the risk of error by remaining aware of the possibility of alternative hypotheses as long as they did not have the results of investigations. Understanding the diagnostic process used by emergency physicians provides interesting ideas for training residents in a specialty in which the prevalence of reasoning errors leading to incorrect diagnoses is high. Copyright © 2014 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
A diagnostic model to estimate winds and small-scale drag from Mars Observer PMIRR data
NASA Technical Reports Server (NTRS)
Barnes, J. R.
1993-01-01
Theoretical and modeling studies indicate that small-scale drag due to breaking gravity waves is likely to be of considerable importance for the circulation in the middle atmospheric region (approximately 40-100 km altitude) on Mars. Recent earth-based spectroscopic observations have provided evidence for the existence of circulation features, in particular, a warm winter polar region, associated with gravity wave drag. Since the Mars Observer PMIRR experiment will obtain temperature profiles extending from the surface up to about 80 km altitude, it will be extensively sampling middle atmospheric regions in which gravity wave drag may play a dominant role. Estimating the drag then becomes crucial to the estimation of the atmospheric winds from the PMIRR-observed temperatures. An interative diagnostic model based upon one previously developed and tested with earth satellite temperature data will be applied to the PMIRR measurements to produce estimates of the small-scale zonal drag and three-dimensional wind fields in the Mars middle atmosphere. This model is based on the primitive equations, and can allow for time dependence (the time tendencies used may be based upon those computed in a Fast Fourier Mapping procedure). The small-scale zonal drag is estimated as the residual in the zonal momentum equation; the horizontal winds having first been estimated from the meridional momentum equation and the continuity equation. The scheme estimates the vertical motions from the thermodynamic equation, and thus needs estimates of the diabatic heating based upon the observed temperatures. The latter will be generated using a radiative model. It is hoped that the diagnostic scheme will be able to produce good estimates of the zonal gravity wave drag in the Mars middle atmosphere, estimates that can then be used in other diagnostic or assimilation efforts, as well as more theoretical studies.
Trushkowsky, Richard; Arias, David Montalvo; David, Steven
Prior to initiating any treatment, it is necessary to visualize the desired outcomes. It then becomes possible to formulate the steps required to achieve this result. Digital Smile Design (DSD) utilizes patient input and information gathered through diagnostic procedures to create an esthetic treatment scheme. In the case presented here, the NYUCD Esthetic Evaluation Form, intraoral and extraoral photographs, mounted diagnostic casts, physical examination, and radiographs were the diagnostic modalities. The gathered information served as a starting point for a wax-up and intraoral mock-up. This case report demonstrates how the DSD served as a template for crown lengthening procedures and design of the final porcelain veneer restorations.
Current audiological diagnostics
Hoth, Sebastian; Baljić, Izet
2017-01-01
Today’s audiological functional diagnostics is based on a variety of hearing tests, whose large number takes account of the variety of malfunctions of a complex sensory organ system and the necessity to examine it in a differentiated manner and at any age of life. The objective is to identify nature and origin of the hearing loss and to quantify its extent as far as necessary to dispose of the information needed to initiate the adequate medical (conservative or operational) treatment or the provision with technical hearing aids or prostheses. Moreover, audiometry provides the basis for the assessment of impairment and handicap as well as for the calculation of the degree of disability. In the present overview, the current state of the method inventory available for practical use is described, starting from basic diagnostics over to complex special techniques. The presentation is systematically grouped in subjective procedures, based on psychoacoustic exploration, and objective methods, based on physical measurements: preliminary hearing tests, pure tone threshold, suprathreshold processing of sound intensity, directional hearing, speech understanding in quiet and in noise, dichotic hearing, tympanogram, acoustic reflex, otoacoustic emissions and auditory evoked potentials. Apart from a few still existing gaps, this method inventory covers the whole spectrum of all clinically relevant functional deficits of the auditory system. PMID:29279727
Circulating microRNA-based screening tool for breast cancer
Boukerroucha, Meriem; Fasquelle, Corinne; Thiry, Jérôme; Bovy, Nicolas; Struman, Ingrid; Geurts, Pierre; Collignon, Joëlle; Schroeder, Hélène; Kridelka, Frédéric; Lifrange, Eric; Jossa, Véronique
2016-01-01
Circulating microRNAs (miRNAs) are increasingly recognized as powerful biomarkers in several pathologies, including breast cancer. Here, their plasmatic levels were measured to be used as an alternative screening procedure to mammography for breast cancer diagnosis. A plasma miRNA profile was determined by RT-qPCR in a cohort of 378 women. A diagnostic model was designed based on the expression of 8 miRNAs measured first in a profiling cohort composed of 41 primary breast cancers and 45 controls, and further validated in diverse cohorts composed of 108 primary breast cancers, 88 controls, 35 breast cancers in remission, 31 metastatic breast cancers and 30 gynecologic tumors. A receiver operating characteristic curve derived from the 8-miRNA random forest based diagnostic tool exhibited an area under the curve of 0.81. The accuracy of the diagnostic tool remained unchanged considering age and tumor stage. The miRNA signature correctly identified patients with metastatic breast cancer. The use of the classification model on cohorts of patients with breast cancers in remission and with gynecologic cancers yielded prediction distributions similar to that of the control group. Using a multivariate supervised learning method and a set of 8 circulating miRNAs, we designed an accurate, minimally invasive screening tool for breast cancer. PMID:26734993
Automated extraction of knowledge for model-based diagnostics
NASA Technical Reports Server (NTRS)
Gonzalez, Avelino J.; Myler, Harley R.; Towhidnejad, Massood; Mckenzie, Frederic D.; Kladke, Robin R.
1990-01-01
The concept of accessing computer aided design (CAD) design databases and extracting a process model automatically is investigated as a possible source for the generation of knowledge bases for model-based reasoning systems. The resulting system, referred to as automated knowledge generation (AKG), uses an object-oriented programming structure and constraint techniques as well as internal database of component descriptions to generate a frame-based structure that describes the model. The procedure has been designed to be general enough to be easily coupled to CAD systems that feature a database capable of providing label and connectivity data from the drawn system. The AKG system is capable of defining knowledge bases in formats required by various model-based reasoning tools.
He, Xiaoning; Holtorf, Anke-Peggy; Rinde, Harald; Xie, Shuangshuang; Shen, Wen; Hou, Jiancun; Li, Xuehua; Li, Ziping; Lai, Jiaming; Wang, Yuting; Zhang, Lin; Wang, Jian; Li, Xuesong; Ma, Kuansheng; Ye, Feng; Ouyang, Han; Zhao, Hong
2018-01-01
Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media–enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803) and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China. PMID:29324837
Tavares, J B; Sacadura-Leite, E; Matoso, T; Neto, L L; Biscoito, L; Campos, J; Sousa-Uva, A
2016-06-01
In interventional neuroradiology, few operators routinely use radiation protection glasses. Moreover, in most centers, radiation dose data only accounts for whole body dose without specific information on lens dose. In 2012, the International Commission on Radiological Protection advised that the threshold limit value for the lens should be 20 mSv/year instead of the previous 150 mSv/year limit. The purpose of this study was to compare the radiation dose in the operator's lens during real diagnostic and interventional neuroangiographies, either using or without lead protection glasses. Using the Educational Direct Dosimeter (EDD30 dosimeter), accumulated radiation dose in the lens was measured in 13 neuroangiographies: seven diagnostic and six interventional. Operators with and without radiation protection glasses were included and the sensor was placed near their left eye, closest to the radiation beam. Without glasses, the corrected mean dose of radiation in the lens was 8.02 µSv for diagnostic procedures and 168.57 µSv for interventional procedures. Using glasses, these values were reduced to 1.74 µSv and 33.24 µSv, respectively. Considering 20 mSv as the suggested annual limit of equivalent dose in the lens, neuroradiologists may perform up to 2,494 diagnostic procedures per year without protecting glasses, a number that increases to 11,494 when glasses are used consistently. Regarding intervention, a maximum of 119 procedures per year is advised if glasses are not used, whereas up to 602 procedures/year may be performed using this protection. Therefore, neuroradiologists should always wear radiation protection glasses. © The Author(s) 2016.
Lenz, Philipp; Roggel, Moritz; Domagk, Dirk
2013-09-01
This study aims to compare double- (DBE) and single-balloon enteroscopy (SBE) in small bowel disorders with respect to procedural performance and clinical impact. This retrospective analysis at a tertial referral center included 1,052 DBEs and 515 SBEs performed in 904 patients over 7 years. Procedural and patients' characteristics were precisely analyzed. Significantly more patients with anemia and gastrointestinal bleeding were investigated by DBE (P < 0.01). Oral insertion depth and length of investigated small bowel in the combined approach were significantly higher in the DBE compared to the SBE group (245 ± 65.3 vs. 218 ± 62.6 and 355 ± 101.9 vs. 319 ± 91.2, respectively; P < 0.001, each). By analyzing only recent years of enteroscopy (2008-2011), no difference in small bowel visualization could be observed. The anal insertion depths and complete enteroscopy rates (CER) were comparable. Procedure times were significantly shorter within the SBE procedure (oral: 50 vs. 40 min; anal: 55 vs. 46 min, P < 0.001) and the usage of sedation was significantly less (propofol: P < 0.001; pethidine: P < 0.05). Diagnostic yield was significantly higher in the SBE, compared to the DBE group (61.7 vs. 48.2 %; P < 0.001). The rate of severe adverse events was close to zero. Both enteroscopy techniques are safe diagnostic tools and proved to be indispensable in the daily gastroenterological practice. The lower insertion depths, but higher diagnostic yield, of SBE may reflect the more focused selection of patients scheduled for small bowel diagnostics in recent years.
[Management of breast nipple discharge: Recommendations].
Ouldamer, L; Kellal, I; Legendre, G; Ngô, C; Chopier, J; Body, G
2015-12-01
To investigate diagnostic value of imaging procedures and management strategies of the patients with nipple discharge (ND) to establish management recommendations. Bibliographical search in French and English languages by consultation of PubMed, Cochrane and Embase databases. Although, all ND require an systematic evaluation guided by clinical data, bloody ND could be a predictor of breast cancer risk among different colors of discharge particularly in patients of more than 50 years (LE2). The mammography and breast ultrasography are the imaging procedures to realize in first intention (grade C) but they turn out useful only when they detect radiological abnormalities (LE4). Galactography has only a localizing value of possible ductal abnormalities (when standard imaging procedures is not contributive) (LE4). Thus, in the diagnostic investigation of a suspicious ND, galactography it is not recommended in standard practice (grade C). The breast Magnetic Resonance Imaging (MRI) is recommended when breast standard imaging procedures are not contributive (grade C). The ND cytology is useful only if it is positive (i.e. reveal cancer cells). There is no proof on the diagnostic performance of the cytological analysis of the ND to allow a recommendation on its realization or not. In front of a suspicious ND, when breast-imaging procedures reveals an associated radiological lesion, an adapted percutaneous biopsy is recommended by percutaneous way (grade C). Vacuum-assisted breast biopsies is a diagnostic tool but can also be therapeutic allowing to avoid surgery in case of benign lesion but current literature data do not allow recommendations on the therapeutic aspect of vacuum-assisted breast biopsy (LE4). In the absence of associated radiological signal, and in case of reproducible bloody persistent ND, a pyramidectomy is recommended (grade C). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Image standards in tissue-based diagnosis (diagnostic surgical pathology).
Kayser, Klaus; Görtler, Jürgen; Goldmann, Torsten; Vollmer, Ekkehard; Hufnagl, Peter; Kayser, Gian
2008-04-18
Progress in automated image analysis, virtual microscopy, hospital information systems, and interdisciplinary data exchange require image standards to be applied in tissue-based diagnosis. To describe the theoretical background, practical experiences and comparable solutions in other medical fields to promote image standards applicable for diagnostic pathology. THEORY AND EXPERIENCES: Images used in tissue-based diagnosis present with pathology-specific characteristics. It seems appropriate to discuss their characteristics and potential standardization in relation to the levels of hierarchy in which they appear. All levels can be divided into legal, medical, and technological properties. Standards applied to the first level include regulations or aims to be fulfilled. In legal properties, they have to regulate features of privacy, image documentation, transmission, and presentation; in medical properties, features of disease-image combination, human-diagnostics, automated information extraction, archive retrieval and access; and in technological properties features of image acquisition, display, formats, transfer speed, safety, and system dynamics. The next lower second level has to implement the prescriptions of the upper one, i.e. describe how they are implemented. Legal aspects should demand secure encryption for privacy of all patient related data, image archives that include all images used for diagnostics for a period of 10 years at minimum, accurate annotations of dates and viewing, and precise hardware and software information. Medical aspects should demand standardized patients' files such as DICOM 3 or HL 7 including history and previous examinations, information of image display hardware and software, of image resolution and fields of view, of relation between sizes of biological objects and image sizes, and of access to archives and retrieval. Technological aspects should deal with image acquisition systems (resolution, colour temperature, focus, brightness, and quality evaluation procedures), display resolution data, implemented image formats, storage, cycle frequency, backup procedures, operation system, and external system accessibility. The lowest third level describes the permitted limits and threshold in detail. At present, an applicable standard including all mentioned features does not exist to our knowledge; some aspects can be taken from radiological standards (PACS, DICOM 3); others require specific solutions or are not covered yet. The progress in virtual microscopy and application of artificial intelligence (AI) in tissue-based diagnosis demands fast preparation and implementation of an internationally acceptable standard. The described hierarchic order as well as analytic investigation in all potentially necessary aspects and details offers an appropriate tool to specifically determine standardized requirements.
Shoulder-Mounted Robot for MRI-guided arthrography: Accuracy and mounting study.
Monfaredi, R; Wilson, E; Sze, R; Sharma, K; Azizi, B; Iordachita, I; Cleary, K
2015-08-01
A new version of our compact and lightweight patient-mounted MRI-compatible 4 degree-of-freedom (DOF) robot for MRI-guided arthrography procedures is introduced. This robot could convert the traditional two-stage arthrography procedure (fluoroscopy-guided needle insertion followed by a diagnostic MRI scan) to a one-stage procedure, all in the MRI suite. The results of a recent accuracy study are reported. A new mounting technique is proposed and the mounting stability is investigated using optical and electromagnetic tracking on an anthropomorphic phantom. Five volunteer subjects including 2 radiologists were asked to conduct needle insertion in 4 different random positions and orientations within the robot's workspace and the displacement of the base of the robot was investigated during robot motion and needle insertion. Experimental results show that the proposed mounting method is stable and promising for clinical application.
How do gut feelings feature in tutorial dialogues on diagnostic reasoning in GP traineeship?
Stolper, C F; Van de Wiel, M W J; Hendriks, R H M; Van Royen, P; Van Bokhoven, M A; Van der Weijden, T; Dinant, G J
2015-05-01
Diagnostic reasoning is considered to be based on the interaction between analytical and non-analytical cognitive processes. Gut feelings, a specific form of non-analytical reasoning, play a substantial role in diagnostic reasoning by general practitioners (GPs) and may activate analytical reasoning. In GP traineeships in the Netherlands, trainees mostly see patients alone but regularly consult with their supervisors to discuss patients and problems, receive feedback, and improve their competencies. In the present study, we examined the discussions of supervisors and their trainees about diagnostic reasoning in these so-called tutorial dialogues and how gut feelings feature in these discussions. 17 tutorial dialogues focussing on diagnostic reasoning were video-recorded and transcribed and the protocols were analysed using a detailed bottom-up and iterative content analysis and coding procedure. The dialogues were segmented into quotes. Each quote received a content code and a participant code. The number of words per code was used as a unit of analysis to quantitatively compare the contributions to the dialogues made by supervisors and trainees, and the attention given to different topics. The dialogues were usually analytical reflections on a trainee's diagnostic reasoning. A hypothetico-deductive strategy was often used, by listing differential diagnoses and discussing what information guided the reasoning process and might confirm or exclude provisional hypotheses. Gut feelings were discussed in seven dialogues. They were used as a tool in diagnostic reasoning, inducing analytical reflection, sometimes on the entire diagnostic reasoning process. The emphasis in these tutorial dialogues was on analytical components of diagnostic reasoning. Discussing gut feelings in tutorial dialogues seems to be a good educational method to familiarize trainees with non-analytical reasoning. Supervisors need specialised knowledge about these aspects of diagnostic reasoning and how to deal with them in medical education.
Yarmus, Lonny; Feller-Kopman, David; Imad, Melhem; Kim, Stephanie; Lee, Hans J
2013-09-01
Current interventional pulmonary (IP) procedural guidelines for competency are based on expert opinion. There are few objective data to support competency metrics for IP procedures. This survey reports procedural volume during IP fellowships to help define new standards in training and curriculum development. A web-based survey was developed to evaluate IP training procedural volume. The survey was administered to all US and Canadian IP fellowship directors and graduates in training from 2006 to 2011. The survey inquired about all diagnostic and therapeutic procedures performed during the specialized year of IP training. Questions regarding the training program structure were collected and analyzed. There was a 92.5% fellow response rate (37 of 40) and 77% fellowship director response rate (10 of 13) from programs in existence at the time of the survey. Procedural volume was consistent between fellowship directors and graduates (P = .64). Although there was a wide range of procedural volume and types of procedures between different programs, the procedural mean volumes were all significantly higher than the American College of Chest Physicians (ACCP) and American Thoracic Society/European Respiratory Society (ATS/ERS) guideline recommendations (P < .005). US and Canadian IP fellowships produce fellows with variable procedural volumes; however, these are significantly higher than ACCP and ATS/ERS guidelines for most programs and procedures. With a uniform training curriculum being adopted by the majority of IP fellowship programs in the United States and Canada, as well as data showing improved core knowledge in IP fellows undergoing a dedicated year of additional training, further metrics examining the impact of advanced IP training on patient outcomes are needed.
Sauerland, Melanie; Wolfs, Andrea C F; Crans, Samantha; Verschuere, Bruno
2017-11-27
Direct eyewitness identification is widely used, but prone to error. We tested the validity of indirect eyewitness identification decisions using the reaction time-based concealed information test (CIT) for assessing cooperative eyewitnesses' face memory as an alternative to traditional lineup procedures. In a series of five experiments, a total of 401 mock eyewitnesses watched one of 11 different stimulus events that depicted a breach of law. Eyewitness identifications in the CIT were derived from longer reaction times as compared to well-matched foil faces not encountered before. Across the five experiments, the weighted mean effect size d was 0.14 (95% CI 0.08-0.19). The reaction time-based CIT seems unsuited for testing cooperative eyewitnesses' memory for faces. The careful matching of the faces required for a fair lineup or the lack of intent to deceive may have hampered the diagnosticity of the reaction time-based CIT.
Dagassan-Berndt, Dorothea C; Zitzmann, Nicola U; Walter, Clemens; Schulze, Ralf K W
2016-08-01
To evaluate the impact of cone beam computed tomography (CBCT) imaging on treatment planning regarding augmentation procedures for implant placement. Panoramic radiographs and CBCT images of 40 patients requesting single-tooth implants in 59 sites were retrospectively analyzed by six specialists in implantology, and treatment planning was performed. Therapeutic recommendations were compared with the surgical protocol performed initially. Bone height estimation from panoramic radiographs yielded to higher measures and greater variability compared to CBCT. The suggested treatment plan for lateral and vertical augmentation procedures based on CBCT or panoramic radiographs coincided for 55-72% of the cases. A trend to a more invasive augmentation procedure was seen when planning was based on CBCT. Panoramic radiography revealed 57-63% (lateral) vs. 67% (vertical augmentation) congruent plans in agreement with surgery. Among the dissenting sites, there was a trend toward less invasive planning for lateral augmentation with panoramic radiographs, while vertical augmentation requirements were more frequently more invasive when based on CBCT. Vertical augmentation requirements can be adequately determined from panoramic radiographs. In difficult cases with a deficient lateral alveolar bone, the augmentation schedule may better be evaluated from CBCT to avoid underestimation, which occurs more frequently when based on panoramic radiographs only. However, overall, radiographic interpretation and diagnostic thinking accuracy seem to be mainly depending on the opinion of observers. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Exhaled Breath Markers for Nonimaging and Noninvasive Measures for Detection of Multiple Sclerosis.
Broza, Yoav Y; Har-Shai, Lior; Jeries, Raneen; Cancilla, John C; Glass-Marmor, Lea; Lejbkowicz, Izabella; Torrecilla, José S; Yao, Xuelin; Feng, Xinliang; Narita, Akimitsu; Müllen, Klaus; Miller, Ariel; Haick, Hossam
2017-11-15
Multiple sclerosis (MS) is the most common chronic neurological disease affecting young adults. MS diagnosis is based on clinical characteristics and confirmed by examination of the cerebrospinal fluids (CSF) or by magnetic resonance imaging (MRI) of the brain or spinal cord or both. However, neither of the current diagnostic procedures are adequate as a routine tool to determine disease state. Thus, diagnostic biomarkers are needed. In the current study, a novel approach that could meet these expectations is presented. The approach is based on noninvasive analysis of volatile organic compounds (VOCs) in breath. Exhaled breath was collected from 204 participants, 146 MS and 58 healthy control individuals. Analysis was performed by gas-chromatography mass-spectrometry (GC-MS) and nanomaterial-based sensor array. Predictive models were derived from the sensors, using artificial neural networks (ANNs). GC-MS analysis revealed significant differences in VOC abundance between MS patients and controls. Sensor data analysis on training sets was able to discriminate in binary comparisons between MS patients and controls with accuracies up to 90%. Blinded sets showed 95% positive predictive value (PPV) between MS-remission and control, 100% sensitivity with 100% negative predictive value (NPV) between MS not-treated (NT) and control, and 86% NPV between relapse and control. Possible links between VOC biomarkers and the MS pathogenesis were established. Preliminary results suggest the applicability of a new nanotechnology-based method for MS diagnostics.
Castrogiovanni, P; Cassano, G B; Conti, L; Maggini, C; Bonollo, L; Sarteschi, P
1976-01-01
One of the main unsolved problems, and one which produces divergent results in clinical psychopharmacology, is that concerning the selection of patients and their diagnostic definition. An automated diagnostic procedure (PDA) was set up in order to classify each patient into one nosographic category on the basis of a cross-sectional examination of his mental state. Such diagnostic procedure appears particularly suitable for multicenter drug trials, since it gives a profile and a diagnostic definition of patients, assessed by investigators from different areas and with different cultural, and clinical backgrounds. In a multicenter trial (sulpiride versus haloperidol) PDA offered a chance to re-examine and analyze the characteristics of each patient and therefore to control the criteria followed for the sample selection in the various experimental settings. The agreement between clinician and computer diagnosis was 78.9%; this agreement rises to 85.5% if the computerlabelled schizo-affective syndromes are considered within the schizophrenic group. Moreover, and attempt has been made to relate psychopathological patterns to drug responses.
NASA Astrophysics Data System (ADS)
Biss, Matthew; Murphy, Michael; Lieber, Mark
2017-06-01
Experiments were conducted in an effort to qualify a multi-diagnostic characterization procedure for the performance output of a detonator when fired into a poly(methyl methacrylate) (PMMA) witness block. A suite of optical diagnostics were utilized in combination to both bound the shock wave interaction state at the detonator/PMMA interface and characterize the nature of the shock wave decay in PMMA. The diagnostics included the Shock Wave Image Framing Technique (SWIFT), a photocathode tube streak camera, and photonic Doppler velocimetry (PDV). High-precision, optically clear witness blocks permitted dynamic flow visualization of the shock wave in PMMA via focused shadowgraphy. SWIFT- and streak-imaging diagnostics captured the spatiotemporally evolving shock wave, providing a two-dimensional temporally discrete image set and a one-dimensional temporally continuous image, respectively. PDV provided the temporal velocity history of the detonator output along the detonator axis. Through combination of the results obtained, a bound was able to be placed on the interface condition and a more-physical profile representing the shock wave decay in PMMA for an exploding-bridgewire detonator was achieved.
Foglia, Emanuela; Ferrario, Lucrezia; Garagiola, Elisabetta; Signoriello, Giuseppe; Pellino, Gianluca; Croce, Davide; Canonico, Silvestro
2017-01-01
Purpose Surgical-site complications (SSCs) affect patients’ clinical pathway, prolonging their hospitalization and incrementing their management costs. The present study aimed to assess the economic and organizational implications of a portable device for negative-pressure wound therapy (NPWT) implementation, compared with the administration of pharmacological therapies alone for preventing surgical complications in patients undergoing general, cardiac, obstetrical–gynecological, or orthopedic surgical procedures. Patients and methods A total of 8,566 hospital procedures, related to the year 2015 from one hospital, were evaluated considering infection risk index, occurrence rates of SSCs, drug therapies, and surgical, diagnostic, and specialist procedures and hematological exams. Activity-based costing and budget impact analyses were implemented for the economic assessment. Results Patients developing an SSC absorbed i) 64.27% more economic resources considering the length of stay (€ 8,269±2,096 versus € 5,034±2,901, p<0.05) and ii) 42.43% more economic resources related to hematological and diagnostic procedures (€ 639±117 versus € 449±72, p<0.05). If the innovative device had been used over the 12-month time period, it would have decreased the risk of developing SSCs; the hospital would have realized an average reduction in health care expenditure equal to −0.69% (−€ 483,787.92) and an organizational saving in terms of length of stay equal to −1.10% (−898 days), thus allowing 95 additional procedures. Conclusion The implementation of a portable device for NPWT would represent an effective and sustainable strategy for reducing the management costs of patients. Economic and organizational savings could be reinvested, thus i) treating a wider population and ii) reducing waiting lists, with a higher effectiveness in terms of a decrease in complications. PMID:28652788
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Donald L.; Hilohi, C. Michael; Spelic, David C.
2012-10-15
Purpose: To determine patient radiation doses from interventional cardiology procedures in the U.S and to suggest possible initial values for U.S. benchmarks for patient radiation dose from selected interventional cardiology procedures [fluoroscopically guided diagnostic cardiac catheterization and percutaneous coronary intervention (PCI)]. Methods: Patient radiation dose metrics were derived from analysis of data from the 2008 to 2009 Nationwide Evaluation of X-ray Trends (NEXT) survey of cardiac catheterization. This analysis used deidentified data and did not require review by an IRB. Data from 171 facilities in 30 states were analyzed. The distributions (percentiles) of radiation dose metrics were determined for diagnosticmore » cardiac catheterizations, PCI, and combined diagnostic and PCI procedures. Confidence intervals for these dose distributions were determined using bootstrap resampling. Results: Percentile distributions (advisory data sets) and possible preliminary U.S. reference levels (based on the 75th percentile of the dose distributions) are provided for cumulative air kerma at the reference point (K{sub a,r}), cumulative air kerma-area product (P{sub KA}), fluoroscopy time, and number of cine runs. Dose distributions are sufficiently detailed to permit dose audits as described in National Council on Radiation Protection and Measurements Report No. 168. Fluoroscopy times are consistent with those observed in European studies, but P{sub KA} is higher in the U.S. Conclusions: Sufficient data exist to suggest possible initial benchmarks for patient radiation dose for certain interventional cardiology procedures in the U.S. Our data suggest that patient radiation dose in these procedures is not optimized in U.S. practice.« less
Johansson, L; Thunell, S; Wetterberg, L
1984-03-13
A filter paper dry blood spot procedure for the determination of whole blood uroporphyrinogen-I-synthase (UIS) activity is presented. The method is based on the concept of enzyme specific activity, the enzyme activity being related to the haemoglobin concentration of the assay sample. The diagnostic capacity with regard to the acute intermittent porphyria (AIP) gene carrier state is shown to be equivalent to that of a washed red cell reference method. On grounds of easy capillary blood sampling, uncomplicated and safe mail specimen transport and simple laboratory reception routines, the method is stated to be well adapted for use in AIP preadolescent population screening.
Kojima, Motohiro; Shimazaki, Hideyuki; Iwaya, Keiichi; Kage, Masayoshi; Akiba, Jun; Ohkura, Yasuo; Horiguchi, Shinichiro; Shomori, Kohei; Kushima, Ryoji; Ajioka, Yoichi; Nomura, Shogo; Ochiai, Atsushi
2013-07-01
The goal of this study is to create an objective pathological diagnostic system for blood and lymphatic vessel invasion (BLI). 1450 surgically resected colorectal cancer specimens from eight hospitals were reviewed. Our first step was to compare the current practice of pathology assessment among eight hospitals. Then, H&E stained slides with or without histochemical/immunohistochemical staining were assessed by eight pathologists and concordance of BLI diagnosis was checked. In addition, histological findings associated with BLI having good concordance were reviewed. Based on these results, framework for developing diagnostic criterion was developed, using the Delphi method. The new criterion was evaluated using 40 colorectal cancer specimens. Frequency of BLI diagnoses, number of blocks obtained and stained for assessment of BLI varied among eight hospitals. Concordance was low for BLI diagnosis and was not any better when histochemical/immunohistochemical staining was provided. All histological findings associated with BLI from H&E staining were poor in agreement. However, observation of elastica-stained internal elastic membrane covering more than half of the circumference surrounding the tumour cluster as well as the presence of D2-40-stained endothelial cells covering more than half of the circumference surrounding the tumour cluster showed high concordance. Based on this observation, we developed a framework for pathological diagnostic criterion, using the Delphi method. This criterion was found to be useful in improving concordance of BLI diagnosis. A framework for pathological diagnostic criterion was developed by reviewing concordance and using the Delphi method. The criterion developed may serve as the basis for creating a standardised procedure for pathological diagnosis.
Kojima, Motohiro; Shimazaki, Hideyuki; Iwaya, Keiichi; Kage, Masayoshi; Akiba, Jun; Ohkura, Yasuo; Horiguchi, Shinichiro; Shomori, Kohei; Kushima, Ryoji; Ajioka, Yoichi; Nomura, Shogo; Ochiai, Atsushi
2013-01-01
Aims The goal of this study is to create an objective pathological diagnostic system for blood and lymphatic vessel invasion (BLI). Methods 1450 surgically resected colorectal cancer specimens from eight hospitals were reviewed. Our first step was to compare the current practice of pathology assessment among eight hospitals. Then, H&E stained slides with or without histochemical/immunohistochemical staining were assessed by eight pathologists and concordance of BLI diagnosis was checked. In addition, histological findings associated with BLI having good concordance were reviewed. Based on these results, framework for developing diagnostic criterion was developed, using the Delphi method. The new criterion was evaluated using 40 colorectal cancer specimens. Results Frequency of BLI diagnoses, number of blocks obtained and stained for assessment of BLI varied among eight hospitals. Concordance was low for BLI diagnosis and was not any better when histochemical/immunohistochemical staining was provided. All histological findings associated with BLI from H&E staining were poor in agreement. However, observation of elastica-stained internal elastic membrane covering more than half of the circumference surrounding the tumour cluster as well as the presence of D2-40-stained endothelial cells covering more than half of the circumference surrounding the tumour cluster showed high concordance. Based on this observation, we developed a framework for pathological diagnostic criterion, using the Delphi method. This criterion was found to be useful in improving concordance of BLI diagnosis. Conclusions A framework for pathological diagnostic criterion was developed by reviewing concordance and using the Delphi method. The criterion developed may serve as the basis for creating a standardised procedure for pathological diagnosis. PMID:23592799
Magnetic Levitation Coupled with Portable Imaging and Analysis for Disease Diagnostics.
Knowlton, Stephanie M; Yenilmez, Bekir; Amin, Reza; Tasoglu, Savas
2017-02-19
Currently, many clinical diagnostic procedures are complex, costly, inefficient, and inaccessible to a large population in the world. The requirements for specialized equipment and trained personnel require that many diagnostic tests be performed at remote, centralized clinical laboratories. Magnetic levitation is a simple yet powerful technique and can be applied to levitate cells, which are suspended in a paramagnetic solution and placed in a magnetic field, at a position determined by equilibrium between a magnetic force and a buoyancy force. Here, we present a versatile platform technology designed for point-of-care diagnostics which uses magnetic levitation coupled to microscopic imaging and automated analysis to determine the density distribution of a patient's cells as a useful diagnostic indicator. We present two platforms operating on this principle: (i) a smartphone-compatible version of the technology, where the built-in smartphone camera is used to image cells in the magnetic field and a smartphone application processes the images and to measures the density distribution of the cells and (ii) a self-contained version where a camera board is used to capture images and an embedded processing unit with attached thin-film-transistor (TFT) screen measures and displays the results. Demonstrated applications include: (i) measuring the altered distribution of a cell population with a disease phenotype compared to a healthy phenotype, which is applied to sickle cell disease diagnosis, and (ii) separation of different cell types based on their characteristic densities, which is applied to separate white blood cells from red blood cells for white blood cell cytometry. These applications, as well as future extensions of the essential density-based measurements enabled by this portable, user-friendly platform technology, will significantly enhance disease diagnostic capabilities at the point of care.
[EYECUBE as 3D multimedia imaging in macular diagnostics].
Hassenstein, Andrea; Scholz, F; Richard, G
2011-11-01
In the new generation of EYECUBE devices, the angiography image and the OCT are included in a 3D illustration as an integration. Other diagnostic procedures such as autofluorescence and ICG can also be correlated to the OCT. The aim was to precisely classify various two-dimensional findings in relation to each other. The new generation of OCT devices enables imaging with a low incidence of motion artefacts with very good fundus image quality - and with that, permits a largely automatic classification. The feature enabling the integration of the EYECUBE was further developed with new software, so that not only the topographic image (red-free, autofluorescence) can be correlated to the Cirrus OCT, but also all other findings gathered within the same time frame can be correlated to each other. These were brightened and projected onto the cube surface in a defined interval. The imaging procedures can be selected in a menu toolbar. Topographic volumetry OCT images can be overlayed. The practical application of the new method was tested on patients with macular disorders. By lightening up the results from various diagnostic procedures, it is possible of late to directly compare pathologies to each other and to the OCT results. In all patients (n = 45 eyes) with good single-image quality, the automated integration into the EYECUBE was possible (to a great extent). The application is not dependent on a certain type of device used in the procedures performed. The increasing level of precision in imaging procedures and the handling of large data volumes has led to the possibility of examining each macular diagnostics procedure from the comparative perspective: imaging (photo) with perfusion (FLA, ICG) and morphology (OCT). The exclusion of motion artefacts and the reliable scan position in the course of the imaging process increases the informative value of OCT. © Georg Thieme Verlag KG Stuttgart · New York.
Handheld Fluorescence Microscopy based Flow Analyzer.
Saxena, Manish; Jayakumar, Nitin; Gorthi, Sai Siva
2016-03-01
Fluorescence microscopy has the intrinsic advantages of favourable contrast characteristics and high degree of specificity. Consequently, it has been a mainstay in modern biological inquiry and clinical diagnostics. Despite its reliable nature, fluorescence based clinical microscopy and diagnostics is a manual, labour intensive and time consuming procedure. The article outlines a cost-effective, high throughput alternative to conventional fluorescence imaging techniques. With system level integration of custom-designed microfluidics and optics, we demonstrate fluorescence microscopy based imaging flow analyzer. Using this system we have imaged more than 2900 FITC labeled fluorescent beads per minute. This demonstrates high-throughput characteristics of our flow analyzer in comparison to conventional fluorescence microscopy. The issue of motion blur at high flow rates limits the achievable throughput in image based flow analyzers. Here we address the issue by computationally deblurring the images and show that this restores the morphological features otherwise affected by motion blur. By further optimizing concentration of the sample solution and flow speeds, along with imaging multiple channels simultaneously, the system is capable of providing throughput of about 480 beads per second.
The value of endomyocardial biopsy in diagnosis and guiding therapy.
Khan, Tayyaba; Selvakumar, Dinesh; Trivedi, Siddharth; Rao, Karan; Harapoz, Mehmet; Thiagalingam, Aravinda; Denniss, A Robert; Varikatt, Winny
2017-12-01
Endomyocardial biopsy (EMB) is a highly-specialised procedure that is associated with some controversy as to its diagnostic role due to its inconsistency in diagnosing a wide variety of cardiac diseases. Given the advances and sophistication in echocardiography and cardiac magnetic resonance imaging (MRI), the vast majority of cardiac diseases can be diagnosed by these non-invasive procedures. Under-sampling and the fact that biopsy site is limited to the right side of the interventricular septum further limits its value. In spite of all these limitations, there still remains a group of pathological conditions that require biopsy for a conclusive diagnosis such as myocarditis, amyloidosis, sarcoidosis and giant cell myocarditis. Correct patient selection and the quantity of tissue samples impart a significant influence on the accuracy of the diagnosis, and thus the value of EMB is variable for each patient. The purpose of this study was to evaluate the role of EMB in patient care, through its ability to either change clinical diagnosis or alter patient management. Our study was based in a single teaching centre. An audit of cardiac biopsies performed over a 10 year period identified 250 patients. We assessed indications, histology, electron microscopic findings, final clinical diagnosis and how they influenced patient management. A definite diagnosis on histology was given in 44 of 250 patients (17.6%). Non-specific findings were observed in the remaining 206 patients (82.4%). Histology influenced patient management in 73 (29.2%) patients. Histological examination in the remaining 177 biopsies (70.8%) did not provide a definite diagnosis or influence patient management. It was additionally found that the number of tissue fragments sampled has significant impact on diagnostic accuracy. A more accurate diagnosis of 45% was obtained when ≥5 fragments were sampled, as compared to 1-3 fragments where accuracy dropped to 20%. Our study indicated that sampling for electron microscopy has very limited value. We found that of 245 biopsies sampled for electron microscopy, only three biopsies (1.2%) had diagnostically useful findings. In our institution procedure related complications were observed in 7 of 250 patients (2.8%). The diagnostic value of EMB is important but limited. Strict triaging of patients according to clinical suspicion and adequate sampling of tissue may increase useful diagnostic information. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Westra, Jelmer; Tu, Shengxian; Winther, Simon; Nissen, Louise; Vestergaard, Mai-Britt; Andersen, Birgitte Krogsgaard; Holck, Emil Nielsen; Fox Maule, Camilla; Johansen, Jane Kirk; Andreasen, Lene Nyhus; Simonsen, Jo Krogsgaard; Zhang, Yimin; Kristensen, Steen Dalby; Maeng, Michael; Kaltoft, Anne; Terkelsen, Christian Juhl; Krusell, Lars Romer; Jakobsen, Lars; Reiber, Johan H C; Lassen, Jens Flensted; Bøttcher, Morten; Bøtker, Hans Erik; Christiansen, Evald Høj; Holm, Niels Ramsing
2018-03-01
Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients. WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases. Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717. © 2018 The Authors.
Manca, Claudia; Hill, Carol; Hujer, Andrea M; Patel, Robin; Evans, Scott R; Bonomo, Robert A; Kreiswirth, Barry N
2017-03-15
The Antibacterial Resistance Leadership Group (ARLG) Laboratory Center (LC) leads the evaluation, development, and implementation of laboratory-based research by providing scientific leadership and supporting standard/specialized laboratory services. The LC has developed a physical biorepository and a virtual biorepository. The physical biorepository contains bacterial isolates from ARLG-funded studies located in a centralized laboratory and they are available to ARLG investigators. The Web-based virtual biorepository strain catalogue includes well-characterized gram-positive and gram-negative bacterial strains published by ARLG investigators. The LC, in collaboration with the ARLG Leadership and Operations Center, developed procedures for review and approval of strain requests, guidance during the selection process, and for shipping strains from the distributing laboratories to the requesting investigators. ARLG strains and scientific and/or technical guidance have been provided to basic research laboratories and diagnostic companies for research and development, facilitating collaboration between diagnostic companies and the ARLG Master Protocol for Evaluating Multiple Infection Diagnostics (MASTERMIND) initiative for evaluation of multiple diagnostic devices from a single patient sampling event. In addition, the LC has completed several laboratory-based studies designed to help evaluate new rapid molecular diagnostics by developing, testing, and applying a MASTERMIND approach using purified bacterial strains. In collaboration with the ARLG's Statistical and Data Management Center (SDMC), the LC has developed novel analytical strategies that integrate microbiologic and genetic data for improved and accurate identification of antimicrobial resistance. These novel approaches will aid in the design of future ARLG studies and help correlate pathogenic markers with clinical outcomes. The LC's accomplishments are the result of a successful collaboration with the ARLG's Leadership and Operations Center, Diagnostics and Devices Committee, and SDMC. This interactive approach has been pivotal for the success of LC projects. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Gerstl, Lucia; Schoppe, Nikola; Albers, Lucia; Ertl-Wagner, Birgit; Alperin, Noam; Ehrt, Oliver; Pomschar, Andreas; Landgraf, Mirjam N; Heinen, Florian
2017-11-01
Idiopathic intracranial hypertension (IIH) in children is a rare condition of unknown etiology and various clinical presentations. The primary aim of this study was to evaluate if our pediatric IIH study group fulfilled the revised diagnostic criteria for IIH published in 2013, particularly with regard to clinical presentation and threshold value of an elevated lumbar puncture opening pressure. Additionally we investigated the potential utilization of MR-based and fundoscopic methods of estimating intracranial pressure for improved diagnosis. Clinical data were collected retrospectively from twelve pediatric patients diagnosed with IIH between 2008 and 2012 and revised diagnostic criteria were applied. Comparison with non-invasive methods for measuring intracranial pressure, MRI-based measurement (MR-ICP) and venous ophthalmodynamometry was performed. Only four of the twelve children (33%) fulfilled the revised diagnostic criteria for a definite diagnosis of IIH. Regarding noninvasive methods, MR-ICP (n = 6) showed a significantly higher mean of intracranial pressure compared to a healthy age- and sex-matched control group (p = 0.0043). Venous ophthalmodynamometry (n = 4) showed comparable results to invasive lumbar puncture. The revised diagnostic criteria for IIH may be too strict especially in children without papilledema. MR-ICP and venous ophthalmodynamometry are promising complementary procedures for monitoring disease progression and response to treatment. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Yi, Cai; Lin, Jianhui; Zhang, Weihua; Ding, Jianming
2015-01-01
As train loads and travel speeds have increased over time, railway axle bearings have become critical elements which require more efficient non-destructive inspection and fault diagnostics methods. This paper presents a novel and adaptive procedure based on ensemble empirical mode decomposition (EEMD) and Hilbert marginal spectrum for multi-fault diagnostics of axle bearings. EEMD overcomes the limitations that often hypothesize about data and computational efforts that restrict the application of signal processing techniques. The outputs of this adaptive approach are the intrinsic mode functions that are treated with the Hilbert transform in order to obtain the Hilbert instantaneous frequency spectrum and marginal spectrum. Anyhow, not all the IMFs obtained by the decomposition should be considered into Hilbert marginal spectrum. The IMFs’ confidence index arithmetic proposed in this paper is fully autonomous, overcoming the major limit of selection by user with experience, and allows the development of on-line tools. The effectiveness of the improvement is proven by the successful diagnosis of an axle bearing with a single fault or multiple composite faults, e.g., outer ring fault, cage fault and pin roller fault. PMID:25970256
Vaccine allergy and pseudo-allergy.
Ponvert, Claude; Scheinmann, Pierre
2003-01-01
Allergic and pseudo-allergic reactions to vaccines frequently involve the skin, and can be generalized systemic symptoms (urticaria/angioedema, serum sickness, flares of eczema) or localized at the sites of vaccination (persistent nodules, abcesses, granulomas). Diagnosis of Arthus-type reactions is based on clinical history and specific IgM/IgG anti-toxoid determination. For other local reactions, diagnostic value of non-immediate responses in skin tests varies with clinical symptoms and substances involved. Immediate responses in skin tests and specific IgE determination have good diagnostic and/or predictive value in anaphylaxis and immediate/accelerated urticaria/angioedema to toxoid-, pneumococcus-, and egg- and gelatin-containing vaccines. Diagnosis of reactions to dextran in BCG is based on specific IgM/IgG determination. Most non-immediate generalized reactions result from non-specific inflammation, except for gelatin-containing vaccines, but the diagnostic value of immuno-allergological tests with the vaccines and gelatin are controversial. Withholding booster injections is advised if specific IgM/IgG levels are high. If the levels are low, sequential injections of vaccines containing a single vaccinating agent are usually tolerated. However, injections of the vaccine should be performed using a " desensitization " procedure in patients reporting anaphylaxis and immediate/accelerated urticaria/angioedema.
Breast Cancer Diagnostic System Final Report CRADA No. TC02098.0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rubenchik, A. M.; DaSilva, L. B.
This was a collaborative effort between Lawrence Livermore National Security, LLC (formerly The Regents of the University of California)/Lawrence Liver more National Laboratory (LLNL) and BioTelligent, Inc. together with a Russian Institution (BioFil, Ltd.), to develop a new system ( diagnostic device, operating procedures, algorithms and software) to accurately distinguish between benign and malignant breast tissue (Breast Cancer Diagnostic System, BCDS).
NASA Astrophysics Data System (ADS)
Oliveira, L. S. R.; Conti, C. C.; Amorim, A. S.; Balthar, M. C. V.
2013-03-01
Air kerma is an essential quantity for the calibration of national standards used in diagnostic radiology and the measurement of operating parameters used in radiation protection. Its measurement within the appropriate limits of accuracy, uncertainty and reproducibility is important for the characterization and control of the radiation field for the dosimetry of the patients submitted to diagnostic radiology and, also, for the assessment of the system which produces radiological images. Only the incident beam must be considered for the calculation of the air kerma. Therefore, for energy spectrum, counts apart the total energy deposition in the detector must be subtracted. It is necessary to establish a procedure to sort out the different contributions to the original spectrum and remove the counts representing scattered photons in the detector's materials, partial energy deposition due to the interactions in the detector active volume and, also, the escape peaks contributions. The main goal of this work is to present spectrum stripping procedure, using the MCNP Monte Carlo computer code, for NaI(Tl) scintillation detectors to calculate the air kerma due to an X-ray beam usually used in medical radiology. The comparison between the spectrum before stripping procedure against the reference value showed a discrepancy of more than 63%, while the comparison with the same spectrum after the stripping procedure showed a discrepancy of less than 0.2%.
Vermet, Shannon; McGinnis, Karen; Boodham, Melissa; Gleberzon, Brian J
2010-01-01
The objective of this study was to determine to what extent the diagnostic and therapeutic procedures taught in the undergraduate program used for patients with lumbopelvic conditions are expected to be utilized by students during their clinical internship program at Canadian Memorial Chiropractic College or are being used by the clinical faculty. A confidential survey was distributed to clinical faculty at the college. It consisted of a list of diagnostic and therapeutic procedures used for lumbopelvic conditions taught at that college. Clinicians were asked to indicate the frequency with which they performed or they required students to perform each item. Seventeen of 23 clinicians responded. The following procedures were most likely required to be performed by clinicians: posture; ranges of motion; lower limb sensory, motor, and reflex testing; and core orthopedic tests. The following were less likely to be required to be performed: Waddell testing, Schober's test, Gillet tests, and abdominal palpation. Students were expected to perform (or clinicians performed) most of the mobilization (in particular, iliocostal, iliotransverse, and iliofemoral) and spinal manipulative therapies (in particular, the procedures referred to as the lumbar roll, lumbar pull/hook, and upper sacroiliac) taught at the college. This study suggests that there was considerable, but not complete, vertical integration between the undergraduate and clinical education program at this college.
Dietel, Manfred; Bubendorf, Lukas; Dingemans, Anne-Marie C; Dooms, Christophe; Elmberger, Göran; García, Rosa Calero; Kerr, Keith M; Lim, Eric; López-Ríos, Fernando; Thunnissen, Erik; Van Schil, Paul E; von Laffert, Maximilian
2016-01-01
Background There is currently no Europe-wide consensus on the appropriate preanalytical measures and workflow to optimise procedures for tissue-based molecular testing of non-small-cell lung cancer (NSCLC). To address this, a group of lung cancer experts (see list of authors) convened to discuss and propose standard operating procedures (SOPs) for NSCLC. Methods Based on earlier meetings and scientific expertise on lung cancer, a multidisciplinary group meeting was aligned. The aim was to include all relevant aspects concerning NSCLC diagnosis. After careful consideration, the following topics were selected and each was reviewed by the experts: surgical resection and sampling; biopsy procedures for analysis; preanalytical and other variables affecting quality of tissue; tissue conservation; testing procedures for epidermal growth factor receptor, anaplastic lymphoma kinase and ROS proto-oncogene 1, receptor tyrosine kinase (ROS1) in lung tissue and cytological specimens; as well as standardised reporting and quality control (QC). Finally, an optimal workflow was described. Results Suggested optimal procedures and workflows are discussed in detail. The broad consensus was that the complex workflow presented can only be executed effectively by an interdisciplinary approach using a well-trained team. Conclusions To optimise diagnosis and treatment of patients with NSCLC, it is essential to establish SOPs that are adaptable to the local situation. In addition, a continuous QC system and a local multidisciplinary tumour-type-oriented board are essential. PMID:26530085
RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 2. APPENDICES
The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...
RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 1. TECHNICAL REPORT
The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...
Agrillo, A; Ramieri, V; Bianca, C; Nastro Siniscalchi, E; Fatone, F M G; Arangio, P
2010-07-01
In this work, we propose a self-compiled questionnaire, for those patients showing dysfunctions of the temporomandibular joint. The questionnaire, composed by 33 closed multiple-choice questions, represents one of the steps in the diagnostic procedure, together with the clinical notes compiled by the medical specialist and with the other necessary diagnostic researches. It also has the purpose to make easier anamnesis and clinic procedure and gathering of all informations useful for a right clinical diagnosis, and so for an appropriate therapy.
[Role of interventional radiology in diagnosis and management of the painful spine].
Ruiz Santiago, Fernando; Castellano García, María Del Mar; Aparisi Rodríguez, Francisco
2013-05-13
The aim of this article is to perform a general review of the different radiological percutaneous procedures used to diagnose and treat the many causes of back pain. These procedures can be merely diagnostic, such as discography and biopsy, diagnostic and therapeutic, such as epidural and facets injections, or only therapeutic, such as vertebroplasty, decompressive techniques of the intervertebral disk and tumour ablation. We review the indications, advantages and complications of these techniques. Copyright © 2012 Elsevier España, S.L. All rights reserved.
[Newer diagnostic procedures for chlamydial diseases (author's transl)].
Edlinger, E; Ardoin, P
1981-12-01
Chlamydiales are bacteries showing a growth cycle unique among procaryotes. The two species Chlamydia trachomatis and Chlamydia psittaci are genetically very distant and their pathogenicity for man is very distinct. Human chlamydial infections by Chlamydia trachomatis are diseases chiefly sexually transmitted and their epidemiological importance is growing. The relationship between chlamydial infections, Reiter disease, and cat scratch disease are discussed. The various laboratory diagnostic procedures are reported, including the techniques and their indications; the method of choice is in the majority of cases the isolation of Chlamydia on cell culture.
[Newer diagnostic procedures for chlamydial diseases (author's transl)].
Edlinger, E; Ardoin, P
1982-06-17
Chlamydiales are bacteries showing a growth cycle unique among procaryotes. The two species Chlamydia trachomatis and Chlamydia psittaci are genetically very distant and their pathogenicity for man is very distinct. Human chlamydia infections by Chlamydia trachomatis are diseases chiefly sexually transmitted and their epidemiological importance is growing. The relationship between chlamydial infections, Reiter disease, and cat scratch disease are discussed. The various laboratory diagnostic procedures are reported, including the techniques and their indications; the method of choice is in the majority of cases the isolation of Chlamydia on cell culture.
Ackermann, S.; Schoenenberger, C.-A.; Zanetti-Dällenbach, R.
2016-01-01
Purpose: Ultrasound (US) is a well-established diagnostic procedure for breast examination. We investigated the malignancy rate in solid breast lesions according to their BI-RADS classification with a particular focus on false-negative BI-RADS 3 lesions. We examined whether patient history and clinical findings could provide additional information that would help determine further diagnostic steps in breast lesions. Materials and Methods: We conducted a retrospective study by exploring US BI-RADS in 1469 breast lesions of 1201 patients who underwent minimally invasive breast biopsy (MIBB) from January 2002 to December 2011. Results: The overall sensitivity and specificity of BI-RADS classification was 97.4% and 66.4%, respectively, with a positive (PPV) and negative predictive value (NPV) of 65% and 98%, respectively. In 506 BI-RADS 3 lesions, histology revealed 15 malignancies (2.4% malignancy rate), which corresponds to a false-negative rate (FNR) of 2.6%. Clinical evaluation and patient requests critically influenced the further diagnostic procedure, thereby prevailing over the recommendation given by the BI-RADS 3 classification. Conclusion: Clinical criteria including age, family and personal history, clinical examination, mammography and patient choice ensure adequate diagnostic procedures such as short-term follow-up or MIBB in patients with lesions classified as US-BI-RADS 3. PMID:27689181
[Diagnostic algorithm in chronic myeloproliferative diseases (CMPD)].
Haferlach, Torsten; Bacher, Ulrike; Kern, Wolfgang; Schnittger, Susanne; Haferlach, Claudia
2007-09-15
The Philadelphia-negative chronic myeloproliferative diseases (CMPD) are very complex and heterogeneous disorders. They are represented by polycythemia vera (PV), chronic idiopathic myelofibrosis (CIMF), essential thrombocythemia (ET), CMPD/unclassifiable (CMPD-U), chronic neutrophilic leukemia (CNL), and chronic eosinophilic leukemia/hypereosinophilic syndrome (CEL/HES) according to the WHO classification. Before, diagnostics were mainly focused on clinical and morphological aspects, but in recent years cytogenetics and fluorescence in situ hybridization (FISH) found entrance in routine schedules as chromosomal abnormalities are relevant for prognosis and classification. Recently, there is rapid progress in the field of molecular characterization: the JAK2V617F mutation which shows a high incidence in PV, CIMF, and ET already plays a central role and will probably soon be included in follow-up procedures. Due to the detection of mutations in exon 12 of the JAK2 gene or mutations in the MPL gene the variety of activating mutations in the CMPD is still increasing. In CEL/HES the detection of the FIP1L1-PDGFRA fusion gene and overexpression of PDGFRA and PDGFRB led to targeted therapy with tyrosine kinase inhibitors. Thus, diagnostics in the CMPD transform toward a multimodal diagnostic concept based on a combination of methods - cyto-/histomorphology, cytogenetics, and individual molecular methods which can be included in a diagnostic algorithm.
Delaloge, Suzette; Bonastre, Julia; Borget, Isabelle; Garbay, Jean-Rémi; Fontenay, Rachel; Boinon, Diane; Saghatchian, Mahasti; Mathieu, Marie-Christine; Mazouni, Chafika; Rivera, Sofia; Uzan, Catherine; André, Fabrice; Dromain, Clarisse; Boyer, Bruno; Pistilli, Barbara; Azoulay, Sandy; Rimareix, Françoise; Bayou, El-Hadi; Sarfati, Benjamin; Caron, Hélène; Ghouadni, Amal; Leymarie, Nicolas; Canale, Sandra; Mons, Muriel; Arfi-Rouche, Julia; Arnedos, Monica; Suciu, Voichita; Vielh, Philippe; Balleyguier, Corinne
2016-10-01
Rapid diagnosis is a key issue in modern oncology, for which one-stop breast clinics are a model. We aimed to assess the diagnosis accuracy and procedure costs of a large-scale one-stop breast clinic. A total of 10,602 individuals with suspect breast lesions attended the Gustave Roussy's regional one-stop breast clinic between 2004 and 2012. The multidisciplinary clinic uses multimodal imaging together with ultrasonography-guided fine needle aspiration for masses and ultrasonography-guided and stereotactic biopsies as needed. Diagnostic accuracy was assessed by comparing one-stop diagnosis to the consolidated diagnosis obtained after surgery or biopsy or long-term monitoring. The medical cost per patient of the care pathway was assessed from patient-level data collected prospectively. Sixty-nine percent of the patients had masses, while 31% had micro-calcifications or other non-mass lesions. In 75% of the cases (87% of masses), an exact diagnosis could be given on the same day. In the base-case analysis (i.e. considering only benign and malignant lesions at one-stop and at consolidated diagnoses), the sensitivity of the one-stop clinic was 98.4%, specificity 99.8%, positive and negative predictive values 99.7% and 99.0%. In the sensitivity analysis (reclassification of suspect, atypical and undetermined lesions), diagnostic sensitivity varied from 90.3% to 98.5% and specificity varied from 94.3% to 99.8%. The mean medical cost per patient of one-stop diagnostic procedure was €420. One-stop breast clinic can provide timely and cost-efficient delivery of highly accurate diagnoses and serve as models of care for multiple settings, including rapid screening-linked diagnosis. Copyright © 2016 Elsevier Ltd. All rights reserved.
Adaptive control with an expert system based supervisory level. Thesis
NASA Technical Reports Server (NTRS)
Sullivan, Gerald A.
1991-01-01
Adaptive control is presently one of the methods available which may be used to control plants with poorly modelled dynamics or time varying dynamics. Although many variations of adaptive controllers exist, a common characteristic of all adaptive control schemes, is that input/output measurements from the plant are used to adjust a control law in an on-line fashion. Ideally the adjustment mechanism of the adaptive controller is able to learn enough about the dynamics of the plant from input/output measurements to effectively control the plant. In practice, problems such as measurement noise, controller saturation, and incorrect model order, to name a few, may prevent proper adjustment of the controller and poor performance or instability result. In this work we set out to avoid the inadequacies of procedurally implemented safety nets, by introducing a two level control scheme in which an expert system based 'supervisor' at the upper level provides all the safety net functions for an adaptive controller at the lower level. The expert system is based on a shell called IPEX, (Interactive Process EXpert), that we developed specifically for the diagnosis and treatment of dynamic systems. Some of the more important functions that the IPEX system provides are: (1) temporal reasoning; (2) planning of diagnostic activities; and (3) interactive diagnosis. Also, because knowledge and control logic are separate, the incorporation of new diagnostic and treatment knowledge is relatively simple. We note that the flexibility available in the system to express diagnostic and treatment knowledge, allows much greater functionality than could ever be reasonably expected from procedural implementations of safety nets. The remainder of this chapter is divided into three sections. In section 1.1 we give a detailed review of the literature in the area of supervisory systems for adaptive controllers. In particular, we describe the evolution of safety nets from simple ad hoc techniques, up to the use of expert systems for more advanced supervision capabilities.
Xu, Gelin; Weber, Patrick; Hu, Qiaoling; Xue, Honggang; Audry, Laurent; Li, Chengping; Wu, Jie; Bourhy, Herve
2007-10-01
Monoclonal antibody (MAb)-based capture enzyme-linked immunosorbent assays (ELISA) were developed for the diagnosis of rabies-suspect specimens. A combination of four mouse monoclonal antibodies directed against the rabies virus nucleocapsid was selected and used for the detection. The test was optimized and standardized so that maximum concordance could be maintained with the standard procedures of rabies diagnosis recommended by the WHO expert committee. Using prototype viruses from the different genotypes of lyssavirus and from various geographic origins and phylogenetic lineages, this paper presents a reliable, rapid and transferable diagnostic method, named WELYSSA that readily permits the detection of lyssaviruses belonging to the 7 genotypes of lyssavirus circulating in Europe, Africa, Asia and Oceania. The threshold of detection of lyssavirus nucleocapsids is low (0.8 ng/ml). With a panel of 1030 specimens received for rabies diagnostic testing, this test was found to be highly specific (0.999) and sensitive (0.970) when compared to other recommended rabies diagnostic methods.
Ke, Hengte; Yue, Xiuli; Wang, Jinrui; Xing, Sen; Zhang, Qian; Dai, Zhifei; Tian, Jie; Wang, Shumin; Jin, Yushen
2014-03-26
The integration of multimodal contrast-enhanced diagnostic imaging and therapeutic capabilities could utilize imaging guided therapy to plan the treatment strategy based on the diagnostic results and to guide/monitor the therapeutic procedures. Herein, gold nanoshelled perfluorooctylbromide (PFOB) nanocapsules with PEGylation (PGsP NCs) are constructed by oil-in-water emulsion method to form polymeric PFOB nanocapsules, followed by the formation of PEGylated gold nanoshell on the surface. PGsP NCs could not only provide excellent contrast enhancement for dual modal ultrasound and CT imaging in vitro and in vivo, but also serve as efficient photoabsorbers for photothermal ablation of tumors on xenografted nude mouse model. To our best knowledge, this is the first report of gold nanoshell serving as both CT contrast agents and photoabsorbers for photothermal therapy. The novel multifunctional nanomedicine would be of great value to offer more comprehensive diagnostic information to guide more accurate and effective cancer therapy. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Radiation levels and image quality in patients undergoing chest X-ray examinations
NASA Astrophysics Data System (ADS)
de Oliveira, Paulo Márcio Campos; do Carmo Santana, Priscila; de Sousa Lacerda, Marco Aurélio; da Silva, Teógenes Augusto
2017-11-01
Patient dose monitoring for different radiographic procedures has been used as a parameter to evaluate the performance of radiology services; skin entrance absorbed dose values for each type of examination were internationally established and recommended aiming patient protection. In this work, a methodology for dose evaluation was applied to three diagnostic services: one with a conventional film and two with digital computerized radiography processing techniques. The x-ray beam parameters were selected and "doses" (specifically the entrance surface and incident air kerma) were evaluated based on images approved in European criteria during postero-anterior (PA) and lateral (LAT) incidences. Data were collected from 200 patients related to 200 PA and 100 LAT incidences. Results showed that doses distributions in the three diagnostic services were very different; the best relation between dose and image quality was found in the institution with the chemical film processing. This work contributed for disseminating the radiation protection culture by emphasizing the need of a continuous dose reduction without losing the quality of the diagnostic image.
Ciardo, Diana E; Lucke, Katja; Imhof, Alex; Bloemberg, Guido V; Böttger, Erik C
2010-08-01
The implementation of internal transcribed spacer (ITS) sequencing for routine identification of molds in the diagnostic mycology laboratory was analyzed in a 5-year study. All mold isolates (n = 6,900) recovered in our laboratory from 2005 to 2009 were included in this study. According to a defined work flow, which in addition to troublesome phenotypic identification takes clinical relevance into account, 233 isolates were subjected to ITS sequence analysis. Sequencing resulted in successful identification for 78.6% of the analyzed isolates (57.1% at species level, 21.5% at genus level). In comparison, extended in-depth phenotypic characterization of the isolates subjected to sequencing achieved taxonomic assignment for 47.6% of these, with a mere 13.3% at species level. Optimization of DNA extraction further improved the efficacy of molecular identification. This study is the first of its kind to testify to the systematic implementation of sequence-based identification procedures in the routine workup of mold isolates in the diagnostic mycology laboratory.
Diagnostic value of perinatal autopsies: analysis of 486 cases.
Neşe, Nalan; Bülbül, Yeşim
2018-02-23
Autopsy is a beneficial procedure to determine the cause of death and the frequency of anomalies in perinatal losses. Even in the event of an autopsy not providing any additional information, completion of the procedure confirming the clinical diagnoses gives reassurance to both clinicians and parents. Here we present a 15-year archival study based on findings of perinatal autopsies. Four hundred and eighty-six cases from our archive were reviewed and according to the findings they were divided into three subcategories; (1) miscarriages (MCF); (2) fetuses terminated (FTA) for vital anomalies detected by prenatal ultrasonography; (3) premature or term newborns died within first month of life (neonates: NN). Autopsies were documented and classified according to week/age of cases, anomalies and causes of abortion or death. Two hundred and twenty-six of 486 cases (46.5%) were in MCF group while 227 (46.7%) and 33 (6.8%) were of them in FTA and NN groups, respectively. In FTA group, the most frequent anomaly detected was neural tube defects. In NN group, prematurity related complications were the most common cause of death. The autopsy process was found valuable in 39.7% of all cases. We suggest that autopsy procedure is diagnostically valuable even in situations when there is USG findings that are confirming FTAs or there is no important major fetal or placental anomaly detected in MCFs.
Management of Complications Following Emergency and Elective Surgery for Diverticulitis.
Holmer, Christoph; Kreis, Martin E
2015-04-01
The clinical spectrum of sigmoid diverticulitis (SD) varies from asymptomatic diverticulosis to symptomatic disease with potentially fatal complications. Sigmoid colectomy with restoration of continuity has been the prevailing modality for treating acute and recurrent SD, and is often performed as a laparoscopy-assisted procedure. For elective sigmoid colectomy, the postoperative morbidity rate is 15-20% whereas morbidity rates reach up to 30% in patients who undergo emergency surgery for perforated SD. Some of the more common and serious surgical complications after sigmoid colectomy are anastomotic leaks and peritonitis, wound infections, small bowel obstruction, postoperative bleeding, and injuries to the urinary tract structures. Regarding the management of complications, it makes no difference whether the complication is a result of an emergency or an elective procedure. The present work gives an overview of the management of complications in the surgical treatment of SD based on the current literature. To achieve successful management, early diagnosis is mandatory in cases of deviation from the normal postoperative course. If diagnostic procedures fail to deliver a correlate for the clinical situation of the patient, re-laparotomy or re-laparoscopy still remain among the most important diagnostic and/or therapeutic principles in visceral surgery when a patient's clinical status deteriorates. The ability to recognize and successfully manage complications is a crucial part of the surgical treatment of diverticular disease and should be mastered by any surgeon qualified in this field.
James, Daphne J; Cardew, Paul; Warren-Forward, Helen M
2011-09-01
Ionizing radiation used in diagnostic nuclear medicine procedures has the potential to have biologic effects on a fetus. Nuclear medicine technologists (NMTs) therefore have a responsibility to ensure that they question all patients of childbearing age about their pregnancy status before starting any procedure, to avoid unnecessary fetal irradiation. In Australia, there are no clearly defined practice guidelines to assist NMTs in determining whom to question or how to question their patients. Semistructured interviews were conducted with chief NMTs and staff NMTs in 8 nuclear medicine departments in Australia. Questions were based around 5 areas: regulations and policy, fetal radiation exposure, questioning of the patient, difficulties in determining pregnancy status, and the impact of the use of hybrid imaging. Audio files of the interviews were transcribed and coded. Topics were coded into 5 themes: policy and awareness of guidelines, questioning the patient, radiation knowledge, decisions and assumptions made by NMTs, and the use of pregnancy testing. There was a wide variation in practice between and within departments. NMTs demonstrated a lack of knowledge and awareness of the possible biologic effects of radiation. This study identified a need in Australia for nuclear medicine to arrive at a consensus approach to verifying a patient's pregnancy status so that NMTs can successfully question patients about their pregnancy status. Continuing education programs are also required to keep NMTs up to date in their knowledge.
Advanced Imaging Utilization Trends in Privately Insured Patients From 2007 to 2013.
Horný, Michal; Burgess, James F; Cohen, Alan B
2015-12-01
The aim of the study was to investigate whether the increase in utilization of advanced diagnostic imaging for privately insured patients in 2011 was the beginning of a new trend in imaging utilization growth, or an isolated deviation from the declining trend that began in 2008. We extracted outpatient and inpatient CT, diagnostic ultrasound, MRI, and PET procedures from databases, for the years 2007 to 2013. This study extended previous work, covering 2012 to 2013, using the same methodology. For every year of the study period, we calculated the following: number of procedures per person-year covered by private health insurance; proportion of office and emergency visits that resulted in an imaging session; average payments per procedure; and total payments per person-year covered by private health insurance. Outpatient utilization of CT and PET decreased in both 2012 and 2013; outpatient utilization of MRI mildly increased in 2012, but then decreased in 2013. Outpatient utilization of diagnostic ultrasound showed a very different pattern, increasing throughout the study period. Inpatient utilization of all imaging modalities except PET decreased in both 2012 and 2013. Adjusted payments for all imaging modalities increased in 2012, and then dropped substantially in 2013, except the adjusted payments for diagnostic ultrasound that increased in 2013 again. The trend of increasing utilization of advanced diagnostic imaging seems to be over for some, but not all, imaging modalities. A combination of policy (eg, breast density notification laws), technologic advancement, and wider access seems to be responsible for at least part of an increasing utilization of diagnostic ultrasound. Copyright © 2015 American College of Radiology. All rights reserved.
Diagnostic procedures for Trend Monitoring System (TMS) communications. [coaxial cable bus system
NASA Technical Reports Server (NTRS)
Brown, J. S.; Lenker, M. D.
1979-01-01
A prototype coaxial cable bus communications sytem was developed to support the trend monitoring system (TMS). Troubleshooting procedures are described at the system level. The procedures can be used by repair personnel to isolate a fault in the TMS and to restore the system to operation by swapping out failed components.
Consensus guidelines for lumbar puncture in patients with neurological diseases.
Engelborghs, Sebastiaan; Niemantsverdriet, Ellis; Struyfs, Hanne; Blennow, Kaj; Brouns, Raf; Comabella, Manuel; Dujmovic, Irena; van der Flier, Wiesje; Frölich, Lutz; Galimberti, Daniela; Gnanapavan, Sharmilee; Hemmer, Bernhard; Hoff, Erik; Hort, Jakub; Iacobaeus, Ellen; Ingelsson, Martin; Jan de Jong, Frank; Jonsson, Michael; Khalil, Michael; Kuhle, Jens; Lleó, Alberto; de Mendonça, Alexandre; Molinuevo, José Luis; Nagels, Guy; Paquet, Claire; Parnetti, Lucilla; Roks, Gerwin; Rosa-Neto, Pedro; Scheltens, Philip; Skårsgard, Constance; Stomrud, Erik; Tumani, Hayrettin; Visser, Pieter Jelle; Wallin, Anders; Winblad, Bengt; Zetterberg, Henrik; Duits, Flora; Teunissen, Charlotte E
2017-01-01
Cerebrospinal fluid collection by lumbar puncture (LP) is performed in the diagnostic workup of several neurological brain diseases. Reluctance to perform the procedure is among others due to a lack of standards and guidelines to minimize the risk of complications, such as post-LP headache or back pain. We provide consensus guidelines for the LP procedure to minimize the risk of complications. The recommendations are based on (1) data from a large multicenter LP feasibility study (evidence level II-2), (2) systematic literature review on LP needle characteristics and post-LP complications (evidence level II-2), (3) discussion of best practice within the Joint Programme Neurodegenerative Disease Research Biomarkers for Alzheimer's disease and Parkinson's Disease and Biomarkers for Multiple Sclerosis consortia (evidence level III). Our consensus guidelines address contraindications, as well as patient-related and procedure-related risk factors that can influence the development of post-LP complications. When an LP is performed correctly, the procedure is well tolerated and accepted with a low complication rate.
76 FR 77834 - Scientific Information Request on Intravascular Diagnostic and Imaging Medical Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-14
... solicited to inform our Comparative Effectiveness Review of Intravascular Diagnostic Procedures and Imaging... scientific information on this device will improve the quality of this comparative effectiveness review. AHRQ is requesting this scientific information and conducting this comparative effectiveness review...
Estimating Classification Consistency and Accuracy for Cognitive Diagnostic Assessment
ERIC Educational Resources Information Center
Cui, Ying; Gierl, Mark J.; Chang, Hua-Hua
2012-01-01
This article introduces procedures for the computation and asymptotic statistical inference for classification consistency and accuracy indices specifically designed for cognitive diagnostic assessments. The new classification indices can be used as important indicators of the reliability and validity of classification results produced by…
ASSESSMENT OF DIAGNOSTIC MEASUREMENTS FOR SELECTION FOR RESIDENTIAL RADON MITIGATION
The paper discusses and critiques EPA's experience in conducting house evaluation visits in Florida and Ohio. Suggestions are offered as to the utility and priority to be given to selected diagnostic procedures and measurements. EPA had an experimental program to develop and demo...
Huprich, Steven K; Defife, Jared; Westen, Drew
2014-01-01
We sought to determine whether meaningful subtypes of Dysthymic patients could be identified when grouping them by similar personality profiles. A random, national sample of psychiatrists and clinical psychologists (n=1201) described a randomly selected current patient with personality pathology using the descriptors in the Shedler-Westen Assessment Procedure-II (SWAP-II), completed assessments of patients' adaptive functioning, and provided DSM-IV Axis I and II diagnoses. We applied Q-factor cluster analyses to those patients diagnosed with Dysthymic Disorder. Four clusters were identified-High Functioning, Anxious/Dysphoric, Emotionally Dysregulated, and Narcissistic. These factor scores corresponded with a priori hypotheses regarding diagnostic comorbidity and level of adaptive functioning. We compared these groups to diagnostic constructs described and empirically identified in the past literature. The results converge with past and current ideas about the ways in which chronic depression and personality are related and offer an enhanced means by which to understand a heterogeneous diagnostic category that is empirically grounded and clinically useful. © 2013 Published by Elsevier B.V.
sFlt-1/PlGF ratio test for pre-eclampsia: an economic assessment for the UK.
Vatish, M; Strunz-McKendry, T; Hund, M; Allegranza, D; Wolf, C; Smare, C
2016-12-01
To assess the economic impact of introducing into clinical practice in the UK the soluble fms-like tyrosine kinase (sFlt-1) to placental growth factor (PlGF) ratio test for guiding the management of pre-eclampsia. We used an economic model estimating the incremental value of information, from a UK National Health Service payer's perspective, generated by the sFlt-1/PlGF ratio test, compared with current diagnostic procedures, in guiding the management of women with suspected pre-eclampsia. The economic model estimated costs associated with the diagnosis and management of pre-eclampsia in pregnant women between 24 + 0 and 36 + 6 weeks' gestation, managed in either a 'test' scenario in which the sFlt-1/PlGF test is used in addition to current diagnostic procedures, or a 'no-test' scenario in which clinical decisions are based on current diagnostic procedures alone. Test characteristics and resource use were derived from PROGNOSIS, a non-interventional study in women presenting with clinical suspicion of pre-eclampsia. The main outcome measure from the economic model was the cost per patient per episode of care, from first suspicion of pre-eclampsia to birth. Introduction of the sFlt-1/PlGF ratio test into clinical practice is expected to result in cost savings of £344 per patient compared with a no-test scenario. Savings are generated primarily through an improvement in diagnostic accuracy and subsequent reduction in unnecessary hospitalization. Introducing the sFlt-1/PlGF ratio test into clinical practice in the UK was shown to be cost-saving by reducing unnecessary hospitalization of women at low risk of developing pre-eclampsia. In addition, the test ensures that those women at higher risk are identified and managed appropriately. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology. © 2016 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
Sardanelli, Francesco; Bashir, Humayun; Berzaczy, Dominik; Cannella, Guglielmo; Espeland, Ansgar; Flor, Nicola; Helbich, Thomas; Hunink, Myriam; Malone, Dermot E; Mann, Ritse; Muzzupappa, Claudia; Petersen, Lars J; Riklund, Katrine; Sconfienza, Luca M; Serafin, Zbigniew; Spronk, Sandra; Stoker, Jaap; van Beek, Edwin J R; Vorwerk, Dierk; Di Leo, Giovanni
2014-08-01
To evaluate the inclusion of radiologists or nuclear medicine physicians (imaging specialists) as authors of systematic reviews (SRs) on imaging and imaging-guided diagnostic procedures and to determine the impact of imaging specialists' presence as authors on the overall quality of the reviews. A MEDLINE and EMBASE search was performed for SRs of diagnostic and interventional image-guided procedures that were published from January 2001 to December 2010. SRs about procedures primarily performed by nonimaging specialists were excluded. The inclusion of imaging specialists among the SR authors and the frequency of publication in imaging journals were evaluated. The quality of a subset of 200 SRs (100 most recent SRs with imaging specialists as authors and 100 most recent SRs without imaging specialists as authors) was rated by using a 12-item modified assessment of multiple SRs (AMSTAR) evaluation tool. Spearman, χ(2), and Mann-Whitney statistics were used. From among 3258 retrieved citations, 867 SRs were included in the study. Neuroimaging had the largest number of SRs (28% [241 of 867]), 41% (354 of 867) of SRs concerned diagnostic performance, and 26% (228 of 867) of SRs were published in imaging journals. Imaging specialists were authors (in any position) in 330 (38%) of 867 SRs; they were first authors of 176 SRs and last authors of 161 SRs. SRs with imaging specialists as authors were more often published in imaging journals than in nonimaging journals (54% [179 of 330] vs 9% [49 of 537]; P < .001). The median number of modified AMSTAR quality indicators was nine in SRs with imaging specialists as authors, while that in SRs without imaging specialists as authors was seven (P = .003). Only 38% (330 of 867) of SRs on radiology or nuclear medicine-related imaging published from January 2001 to December 2010 included imaging specialists as authors. However, the inclusion of imaging specialists as authors was associated with a significant increase in the scientific quality (as judged by using a modified AMSTAR scale) of the SR.
Al-Mallah, Adel; Vaithinathan, Asokan G.; Al-Sehlawi, Mahdi; Al-Mannai, Mariam
2017-01-01
Objectives Between 20 to 50% of medical imaging examinations are considered inappropriate, and unnecessary ionizing radiation exposures may lead to cancer. We hypothesized that Bahraini patients who self-present for ionizing radiation procedures are not aware of, and lack the requisite knowledge of, the inherent risks associated with their use than patients prescribed for diagnostic purposes. We attempted to examine and compare the awareness and knowledge of the associated risks of ionizing radiation in common diagnostic radiological procedures between prescribed and self-presenting patients in Bahrain. Methods A cross-sectional survey was carried out among 416 Bahraini patients attending the radiology department of the Salmaniya Medical Complex (SMC), a secondary health care center, who had been referred by primary care physicians or self-presented to the center. Data was collected via face-to-face interviews. Results Prescribed patients (n = 358) had a better awareness than self-presenting (n = 58) patients on all ionizing radiation awareness statements (i.e., risks, permissible levels, willingness to undergo the procedure, and preference for a clinical examination over a radiological procedure) (p < 0.050). Of the 10 knowledge statements, the prescribed patients agreed on four statements than the self-presenting patients: preventing or minimizing exposure improves health, people can prevent or minimize exposure, a lifelong health concern, and radiological procedures offer best diagnoses compared to medical tests or procedures (p < 0.050). Conclusions Bahraini patients who reported to SMC lack awareness and knowledge on ionizing radiation. The proportion of appropriate responses to awareness and knowledge questions were paltry for self-presenting patients and deficient for the prescribed patients in the knowledge segment alone. PMID:29026468
A new diagnostic approach for bilious pleural effusion.
Saraya, Takeshi; Light, Richard W; Sakuma, Sho; Nakamoto, Yasuo; Wada, Shoko; Ishida, Manabu; Inui, Toshiya; Koide, Takashi; Ishii, Haruyuki; Takizawa, Hajime
2016-09-01
Bilious pleural effusion is an extremely rare condition associated with liver diseases, subphrenic or subhepatic abscess formation, biliary peritonitis, and invasive procedures (i.e., percutaneous biliary drainage or liver biopsy). The current diagnostic test is based on the measurement of the ratio of pleural total bilirubin to serum total bilirubin, which is greater than 1 in patients with bilious pleural effusion. Given the low incidence of bilious pleural effusion, the precise diagnostic yield of this ratio based test has not been evaluated. We retrospectively reviewed the medical records of our institution and searched the PubMed database for reports of bilious pleural effusion. We identified a total of 12 cases of bilious pleural effusion (9 from 8 Pubmed reports and 3 from our institutional records). The factors causing this condition were broadly classified into three categories based on the pathophysiology: 1) liver diseases (echinococcosis, tuberculosis and amebiasis); 2) subhepatic/subphrenic abscess or biliary peritonitis, with or without biliary tract obstruction; and 3) iatrogenic disease after percutaneous biliary drainage and/or liver biopsy. The sensitivity of detection was 76.9% when the ratio of pleural total bilirubin to serum total bilirubin was greater than 1. The sensitivity increased to 100% when a combination test including pleural glycoholic acid was adopted. This study demonstrates the high diagnostic yield for bilious pleural effusion using a combination of two test criteria; a ratio of pleural total bilirubin to serum total bilirubin greater than 1 and the presence of pleural glycoholic acid. Copyright © 2016 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ivanov, Arkady P.; Barun, Vladimir V.
2007-05-01
A calculation scheme and an algorithm to simultaneously diagnose several structural and biophysical parameters of skin by reflected light are constructed in the paper. The procedure is based the fact that, after absorption and scattering, light reflected by tissue contains information on its optically active chromophores and structure. The problem on isolating the desired parameters is a spectroscopic one under multiple scattering conditions. The latter considerably complicates the solution of the problem and requires the elaboration of an approach that is specific to the object studied. The procedure presented in the paper is based on spectral tissue model properties proposed earlier and engineering methods for solving the radiative transfer equation. The desired parameters are melanin and blood volume fractions, f and c, epidermis thickness d, mean diameter D of capillaries, and blood oxygenation degree S. Spectral diffuse reflectance R(λ) of skin over the range of 400 to 850 nm was calculated as a first stage. Then the sensitivity of R(λ) to the above parameters was studied to optimize the algorithm by wavelengths and to propose an experimental scheme for diagnostics. It is shown that blood volume fraction and f*d product can be rather surely determined by the reflected green -- red light. One can find f and d separately as well as D by the blue reflectance. The last stage is the derivation of S at about 600 nm.
[Marketing mix in a radiology department: challenges for future radiologists in management].
Claikens, B
1998-08-01
Radiology has gained an enviable position among medial specialities. Developments in new technology expand its horizons and the volume of radiologic imaging techniques and procedures increase far more than the overall growth in health care services. In this position radiology has become a prime target for restrictions, cutbacks, controlled financing in an area of managed care and new national health care policy based on partially fixed budgets. Future health care takers have to choose the best available diagnostic and therapeutic techniques. Evidence based medicine, cost-utility analysis, diagnostic performance analysis, patient outcome analysis, technology assessment and guidelines for practice are means to guide us through our obligatory choice. Our major objective is to use the most performant available imaging technique or intervention to achieve the best possible outcome for our patient at lower possible costs. A strategic response from radiologists is required to meet the imperatives of this new management situation. They must do far more than interpret imaging procedures. They must work as efficient managers of imaging resources, organise their practices and define their marketing-strategies using the different, so-called, marketing-mix elements. The challenges will be great but the rewards are worth our best efforts. In this article we highlight the marketing responsibilities of future radiologists and their clinical practice in this new socio-economic environment and we present different useful marketing tools.
Lecomte, P; Criniere, L; Fagot-Campagna, A; Druet, C; Fuhrman, C
2013-04-01
This study estimated the prevalence of symptoms evocative of obstructive sleep apneoa (OSA) in patients with type 2 diabetes and the proportion of those with evidence of a previous diagnosis or diagnostic procedure. In ENTRED 2007, 8926 people reimbursed for at least three antidiabetic agents within the last 12 months were randomly selected, and 3894 answered a self-administered questionnaire. Symptoms evocative of OSA were defined as frequent snoring with excessive daytime sleepiness and/or witnessed sleep apneoa. Patients were considered to have evidence of a previous diagnostic procedure if they reported an OSA diagnosis or had a sleep recording done, or if a sleep recording was found in the hospital discharge or medical claims database, or if they were currently being treated with nocturnal ventilation. The patients' mean age was 66 years. Around 8.5% reported being diagnosed with OSA, 4.2% were treated with nocturnal ventilation and 16% had symptoms evocative of OSA. Being male, obesity, high blood pressure, insulin treatment, living with a partner, lower educational level and financial difficulties were all associated with symptoms suggestive of OSA. Overall, 13% had evidence of a previous diagnostic procedure, and the rate was 35% among those with symptoms evocative of OSA. OSA is underdiagnosed in French diabetic patients, while the prevalence of symptoms is high. Only 13% of the study population and 35% of those with symptoms suggestive of OSA had benefited from a diagnostic procedure. It is of the utmost importance to better diagnose OSA in the diabetic population. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Chen, Yang K; Parsi, Mansour A; Binmoeller, Kenneth F; Hawes, Robert H; Pleskow, Douglas K; Slivka, Adam; Haluszka, Oleh; Petersen, Bret T; Sherman, Stuart; Devière, Jacques; Meisner, Søren; Stevens, Peter D; Costamagna, Guido; Ponchon, Thierry; Peetermans, Joyce A; Neuhaus, Horst
2011-10-01
The feasibility of single-operator cholangioscopy (SOC) for biliary diagnostic and therapeutic procedures was previously reported. To confirm the utility of SOC in more widespread clinical use. Prospective clinical cohort study. Fifteen endoscopy referral centers in the United States and Europe. Two hundred ninety-seven patients requiring evaluation of bile duct disease or biliary stone therapy. SOC examination and, as indicated, SOC-directed stone therapy or forceps biopsy. Procedural success defined as ability to (1) visualize target lesions and, if indicated, collect biopsy specimens adequate for histological evaluation or (2) visualize biliary stones and initiate fragmentation and removal. The overall procedure success rate was 89% (95% CI, 84%-92%). Adequate tissue for histological examination was secured in 88% of 140 patients who underwent biopsy. Overall sensitivity in diagnosing malignancy was 78% for SOC visual impression and 49% for SOC-directed biopsy. Sensitivity was higher (84% and 66%, respectively) for intrinsic bile duct malignancies. Diagnostic SOC procedures altered clinical management in 64% of patients. Procedure success was achieved in 92% of 66 patients with stones and complete stone clearance during the study SOC session in 71%. The incidence of serious procedure-related adverse events was 7.5% for diagnostic SOC and 6.1% for SOC-directed stone therapy. The study was observational in design with no control group. Evaluation of bile duct disease and biliary stone therapy can be safely performed with a high success rate by using the SOC system. Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Bartels, P H; Bibbo, M; Hutchinson, M L; Gahm, T; Grohs, H K; Gwi-Mak, E; Kaufman, E A; Kaufman, R H; Knight, B K; Koss, L G; Magruder, L E; Mango, L J; McCallum, S M; Melamed, M R; Peebles, A; Richart, R M; Robinowitz, M; Rosenthal, D L; Sauer, T; Schenck, U; Tanaka, N; Topalidis, T; Verhest, A P; Wertlake, P T; Wilbur, D C
1998-01-01
The extension of automation to the diagnostic assessment of clinical materials raises issues of professional responsibility, on the part of both the medical professional and designer of the device. The International Academy of Cytology (IAC) and other professional cytology societies should develop a policy towards automation in the diagnostic assessment of clinical cytologic materials. The following summarizes the discussion of the initial position statement at the International Expert Conference on Diagnostic Cytology Towards the 21st Century, Hawaii, June 1997. 1. The professional in charge of a clinical cytopathology laboratory continues to bear the ultimate medical responsibility for diagnostic decisions made at the facility, whether automated devices are involved or not. 2. The introduction of automated procedures into clinical cytology should under no circumstances lead to a lowering of standards of performance. A prime objective of any guidelines should be to ensure that an automated procedure, in principle, does not expose any patient to new risks, nor should it increase already-existing, inherent risks. 3. Automated devices should provide capabilities for the medical professional to conduct periodic tests of the appropriate performance of the device. 4. Supervisory personnel should continue visual quality control screening of a certain percentage of slides dismissed at primary screening as within normal limits (WNL), even when automated procedures are employed in the laboratory. 5. Specifications for the design of primary screening devices for the detection of cervical cancer issued by the IAC in 1984 were reaffirmed. 6. The setting of numeric performance criteria is the proper charge of regulatory agencies, which also have the power of enforcement. 7. Human expert verification of results represents the "gold standard" at this time. Performance characteristics of computerized cytology devices should be determined by adherence to defined and well-considered protocols. Manufacturers should not claim a new standard of care; this is the responsibility of the medical community and professional groups. 8. Cytology professionals should support the development of procedures that bring about an improvement in diagnostic decision making. Advances in technology should be adopted if they can help solve problems in clinical cytology. The introduction of automated procedures into diagnostic decision making should take place strictly under the supervision and with the active participation and critical evaluation by the professional cytology community. Guidelines should be developed for the communication of technical information about the performance of automated screening devices by the IAC to governmental agencies and national societies. Also, guidelines are necessary for the official communication of IAC concerns to industry, medicolegal entities and the media. Procedures and guidelines for the evaluation of studies pertaining to the performance of automated devices, performance metrics and definitions for evaluation criteria should be established.
Kawano, Shuichi; Maeda, Takuya; Suzuki, Takefumi; Abe, Tatsuhiro; Mikita, Kei; Hamakawa, Yusuke; Ono, Takeshi; Sonehara, Wataru; Miyahira, Yasushi; Kawana, Akihiko
2015-03-01
Loop-mediated isothermal amplification (LAMP) is an innovative molecular technique requiring only a heating device and isothermal conditions to amplify a specific target gene. The results of current microscopic diagnostic tools for pneumocystis pneumonia are not sufficiently consistent for detecting infection with a low-density of Pneumocystis jirovecii. Although polymerase chain reaction (PCR) is highly sensitive, it is not suitable for resource-limited facilities. LAMP is a potential diagnostic replacement for PCR in such settings but a critical disadvantage of DNA extraction was still remained. Therefore, we employed the Procedure for Ultra Rapid Extraction (PURE) kit, which uses a porous material, to isolate the DNA from clinical samples in a simple way in combination with previously reported LAMP procedure for diagnosing PCP. The detection limit of the PURE-LAMP method applied to artificial bronchoalveolar lavage fluid samples was 100 copies/tube, even with the use of massive blood-contaminated solutions. In addition, we concluded the diagnostic procedure within 1 h without the need for additional equipment. PURE-LAMP coupled with suitable primers for specific pathogens has good potential for diagnosing various infectious diseases. Copyright © 2014 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Early diagnostic of concurrent gear degradation processes progressing under time-varying loads
NASA Astrophysics Data System (ADS)
Guilbault, Raynald; Lalonde, Sébastien
2016-08-01
This study develops a gear diagnostic procedure for the detection of multi- and concurrent degradation processes evolving under time-varying loads. Instead of a conventional comparison between a descriptor and an alarm level, this procedure bases its detection strategy on a descriptor evolution tracking; a lasting descriptor increase denotes the presence of ongoing degradation mechanisms. The procedure works from time domain residual signals prepared in the frequency domain, and accepts any gear conditions as reference signature. To extract the load fluctuation repercussions, the procedure integrates a scaling factor. The investigation first examines a simplification assuming a linear connection between the load and the dynamic response amplitudes. However, while generally valuable, the precision losses associated with large load variations may mask the contribution of tiny flaws. To better reflect the real non-linear relation, the paper reformulates the scaling factor; a power law with an exponent value of 0.85 produces noticeable improvements of the load effect extraction. To reduce the consequences of remaining oscillations, the procedure also includes a filtering phase. During the validation program, a synthetic wear progression assuming a commensurate relation between the wear depth and friction assured controlled evolutions of the surface degradation influence, whereas the fillet crack growth remained entirely determined by the operation conditions. Globally, the tested conditions attest that the final strategy provides accurate monitoring of coexisting isolated damages and general surface deterioration, and that its tracking-detection capacities are unaffected by severe time variations of external loads. The procedure promptly detects the presence of evolving abnormal phenomena. The tests show that the descriptor curve shapes virtually describe the constant wear progression superimposed on the crack length evolution. At the tooth fracture, the mean values of the residual signal evince strong perturbations, while after this episode, the monitoring curves continue signaling the ongoing wear process.
Hollow organ perforation in blunt abdominal trauma: the role of diagnostic peritoneal lavage.
Wang, Yu-Chun; Hsieh, Chi-Hsun; Fu, Chih-Yuan; Yeh, Chun-Chieh; Wu, Shih-Chi; Chen, Ray-Jade
2012-05-01
With recent advances in radiologic diagnostic procedures, the use of diagnostic peritoneal lavage (DPL) has markedly declined. In this study, we reviewed data to reevaluate the role of DPL in the diagnosis of hollow organ perforation in patients with blunt abdominal trauma. Adult patients who had sustained blunt abdominal trauma and who were hemodynamically stable after initial resuscitation underwent an abdominal computed tomographic (CT) scan. Diagnostic peritoneal lavage was performed for patients who were indicated to receive nonoperative management and where hollow organ perforation could not be ruled out. During a 60-month period, 64 patients who had received abdominal CT scanning underwent DPL. Nineteen patients were diagnosed as having a positive DPL based on cell count ratio of 1 or higher. There were 4 patients who sustained small bowel perforation. The sensitivity and specificity of the cell count ratio for a hollow organ perforation in this study were 100% and 75%, respectively. No missed hollow organ perforations were detected. For patients with blunt abdominal trauma and hemoperitoneum who plan to receive nonoperative management, DPL is still a useful tool to exclude hollow organ perforation that is undetected by CT. Copyright © 2012 Elsevier Inc. All rights reserved.
Strauer, B E
1988-01-01
The clinical syndrome "coronary insufficience at normal coronary arteriogram" is found in approximately 10-20% of patients with exercise-induced coronary insufficience. In most of these cases disturbances of coronary microcirculation are present. They can appear in vascular diseases (arterial hypertension, systemic immunopathies, immune complex vasculitis, etc.), in rheological diseases (paraproteinemia, hyperlipoproteinemia, polyglobulia, etc.), and in disturbances of transport and diffusion of oxygen (carbon monoxide intoxication, methemoglobinemia, hyperlipoproteinemia). The clinical diagnosis is based on usual diagnostic programs (electrocardiogram, exercise electrocardiogram, responsiveness to nitroglycerin, etc.), as well as on newer, functionally orientated diagnostic procedures (determinations of coronary blood flow and of coronary vascular reserve, production of lactate, serological findings, histology and immune histology of peripheral arteries, measurements of viscosities in both plasma and blood, etc.). Many clinically relevant disturbances in coronary microcirculation can thus be detected and treated on a rational basis by the management of the internal main disease, that is, by the treatment of the vascular, rheological, and metabolic disorders. Persistent angina pectoris in the presence of normal coronary arteriogram represents no termination of coronary diagnostics, but moreover implies the clinical task for using diagnostic possibilities to enable functional and therapeutical assessment of coronary microcirculation.
Statistical inference on censored data for targeted clinical trials under enrichment design.
Chen, Chen-Fang; Lin, Jr-Rung; Liu, Jen-Pei
2013-01-01
For the traditional clinical trials, inclusion and exclusion criteria are usually based on some clinical endpoints; the genetic or genomic variability of the trial participants are not totally utilized in the criteria. After completion of the human genome project, the disease targets at the molecular level can be identified and can be utilized for the treatment of diseases. However, the accuracy of diagnostic devices for identification of such molecular targets is usually not perfect. Some of the patients enrolled in targeted clinical trials with a positive result for the molecular target might not have the specific molecular targets. As a result, the treatment effect may be underestimated in the patient population truly with the molecular target. To resolve this issue, under the exponential distribution, we develop inferential procedures for the treatment effects of the targeted drug based on the censored endpoints in the patients truly with the molecular targets. Under an enrichment design, we propose using the expectation-maximization algorithm in conjunction with the bootstrap technique to incorporate the inaccuracy of the diagnostic device for detection of the molecular targets on the inference of the treatment effects. A simulation study was conducted to empirically investigate the performance of the proposed methods. Simulation results demonstrate that under the exponential distribution, the proposed estimator is nearly unbiased with adequate precision, and the confidence interval can provide adequate coverage probability. In addition, the proposed testing procedure can adequately control the size with sufficient power. On the other hand, when the proportional hazard assumption is violated, additional simulation studies show that the type I error rate is not controlled at the nominal level and is an increasing function of the positive predictive value. A numerical example illustrates the proposed procedures. Copyright © 2013 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, M.
The Abt study of medical physicist work values for radiation oncology physics services, Round IV is completed. It supersedes the Abt III study of 2008. The 2015 Abt study measured qualified medical physicist (QMP) work associated with routine radiation oncology procedures as well as some special procedures. As before, a work model was created to allow the medical physicist to defend QMP work based on both routine and special procedures service mix. The work model can be used to develop a cost justification report for setting charges for radiation oncology physics services. The Abt study Round IV was designed tomore » empower the medical physicist to negotiate a service or employment contract with providers based on measured national QMP workforce and staffing data. For a variety of reasons, the diagnostic imaging contingent of AAPM has had a more difficult time trying estimate workforce requirements than their therapy counterparts. Over the past several years, the Diagnostic Work and Workforce Study Subcommittee (DWWSS) has collected survey data from AAPM members, but the data have been very difficult to interpret. The DWWSS has reached out to include more AAPM volunteers to create a more full and accurate representation of actual clinical practice models on the subcommittee. Though much work remains, through hours of discussion and brainstorming, the DWWSS has somewhat of a clear path forward. This talk will provide attendees with an update on the efforts of the subcommittee. Learning Objectives: Understand the new information documented in the Abt studies. Understand how to use the Abt studies to justify medical physicist staffing. Learn relevant historical information on imaging physicist workforce. Understand the process of the DWWSS in 2014. Understand the intended path forward for the DWWSS.« less
MO-DE-304-00: Workforce Assessment Committee Update
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-06-15
The Abt study of medical physicist work values for radiation oncology physics services, Round IV is completed. It supersedes the Abt III study of 2008. The 2015 Abt study measured qualified medical physicist (QMP) work associated with routine radiation oncology procedures as well as some special procedures. As before, a work model was created to allow the medical physicist to defend QMP work based on both routine and special procedures service mix. The work model can be used to develop a cost justification report for setting charges for radiation oncology physics services. The Abt study Round IV was designed tomore » empower the medical physicist to negotiate a service or employment contract with providers based on measured national QMP workforce and staffing data. For a variety of reasons, the diagnostic imaging contingent of AAPM has had a more difficult time trying estimate workforce requirements than their therapy counterparts. Over the past several years, the Diagnostic Work and Workforce Study Subcommittee (DWWSS) has collected survey data from AAPM members, but the data have been very difficult to interpret. The DWWSS has reached out to include more AAPM volunteers to create a more full and accurate representation of actual clinical practice models on the subcommittee. Though much work remains, through hours of discussion and brainstorming, the DWWSS has somewhat of a clear path forward. This talk will provide attendees with an update on the efforts of the subcommittee. Learning Objectives: Understand the new information documented in the Abt studies. Understand how to use the Abt studies to justify medical physicist staffing. Learn relevant historical information on imaging physicist workforce. Understand the process of the DWWSS in 2014. Understand the intended path forward for the DWWSS.« less
Effect of a teleretinal screening program on eye care use and resources.
Chasan, Joel E; Delaune, Bill; Maa, April Y; Lynch, Mary G
2014-09-01
Telemedicine is a useful clinical method to extend health care to patients with limited access. Minimal information exists on the subsequent effect of telemedicine activities on eye care resources. To evaluate the effect of a community-based diabetic teleretinal screening program on eye care use and resources. The current study was a retrospective medical record review of patients who underwent diabetic teleretinal screening in the community-based clinics of the Atlanta Veterans Affairs Medical Center from October 1, 2008, through March 31, 2009, and who were referred for an ophthalmic examination in the eye clinic. Clinical medical records were reviewed for a 2-year period after patients were referred from teleretinal screening. The following information was collected for analysis: patient demographics, referral and confirmatory diagnoses, ophthalmology clinic visits, diagnostic procedures, surgical procedures, medications, and spectacle prescriptions. The accuracy between referring and final diagnoses and the eye care resources that were used in the care of referred patients. The most common referral diagnoses were nonmacular diabetic retinopathy (43.2%), nerve-related disease (30.8%), lens or media opacity (19.1%), age-related macular degeneration (12.9%), and diabetic macular edema (5.6%). The percentage of agreement among these 5 visually significant diagnoses was 90.4%, with a total sensitivity of 73.6%. Diabetic macular edema required the greatest number of ophthalmology clinic visits, diagnostic tests, and surgical procedures. Using Medicare cost data estimates, the mean cost incurred during a 2-year period per patient seen in the eye clinic was approximately $1000. Although a teleretinal screening program can be accurate and sensitive for multiple visually significant diagnoses, measurable resource burdens should be anticipated to adequately prepare for the associated increase in clinical care.
A five-step procedure for the clinical use of the MPD in neuropsychological assessment of children.
Wallbrown, F H; Fuller, G B
1984-01-01
Described a five-step procedure that can be used to detect organicity on the basis of children's performance on the Minnesota Percepto Diagnostic Test (MPD). The first step consists of examining the T score for rotations to determine whether it is below the cut-off score, which has been established empirically as an indicator of organicity. The second step consists of matching the examinee's configuration of error scores, separation of circle-diamond (SpCD), distortion of circle-diamond (DCD), and distortion of dots (DD), with empirically derived tables. The third step consists of considering the T score for rotations and error configuration jointly. The fourth step consists of using empirically established discriminant equations, and the fifth step involves using data from limits testing and other data sources. The clinical and empirical bases for the five-step procedure also are discussed.
Dynamic metabolic modeling for a MAB bioprocess.
Gao, Jianying; Gorenflo, Volker M; Scharer, Jeno M; Budman, Hector M
2007-01-01
Production of monoclonal antibodies (MAb) for diagnostic or therapeutic applications has become an important task in the pharmaceutical industry. The efficiency of high-density reactor systems can be potentially increased by model-based design and control strategies. Therefore, a reliable kinetic model for cell metabolism is required. A systematic procedure based on metabolic modeling is used to model nutrient uptake and key product formation in a MAb bioprocess during both the growth and post-growth phases. The approach combines the key advantages of stoichiometric and kinetic models into a complete metabolic network while integrating the regulation and control of cellular activity. This modeling procedure can be easily applied to any cell line during both the cell growth and post-growth phases. Quadratic programming (QP) has been identified as a suitable method to solve the underdetermined constrained problem related to model parameter identification. The approach is illustrated for the case of murine hybridoma cells cultivated in stirred spinners.
Sonification of optical coherence tomography data and images
Ahmad, Adeel; Adie, Steven G.; Wang, Morgan; Boppart, Stephen A.
2010-01-01
Sonification is the process of representing data as non-speech audio signals. In this manuscript, we describe the auditory presentation of OCT data and images. OCT acquisition rates frequently exceed our ability to visually analyze image-based data, and multi-sensory input may therefore facilitate rapid interpretation. This conversion will be especially valuable in time-sensitive surgical or diagnostic procedures. In these scenarios, auditory feedback can complement visual data without requiring the surgeon to constantly monitor the screen, or provide additional feedback in non-imaging procedures such as guided needle biopsies which use only axial-scan data. In this paper we present techniques to translate OCT data and images into sound based on the spatial and spatial frequency properties of the OCT data. Results obtained from parameter-mapped sonification of human adipose and tumor tissues are presented, indicating that audio feedback of OCT data may be useful for the interpretation of OCT images. PMID:20588846
Clarke, Diana E.; Wilcox, Holly C.; Miller, Leslie; Cullen, Bernadette; Gerring, Joan; Greiner, Lisa H.; Newcomer, Alison; Mckitty, Mellisha V.; Regier, Darrel A.; Narrow, William E.
2014-01-01
The Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) contains criteria for psychiatric diagnoses that reflect advances in the science and conceptualization of mental disorders and address the needs of clinicians. DSM-5 also recommends research on dimensional measures of cross-cutting symptoms and diagnostic severity, which are expected to better capture patients’ experiences with mental disorders. Prior to its May 2013 release, the American Psychiatric Association (APA) conducted field trials to examine the feasibility, clinical utility, reliability, and where possible, the validity of proposed DSM-5 diagnostic criteria and dimensional measures. The methods and measures proposed for the DSM-5 field trials were pilot tested in adult and child/adolescent clinical samples, with the goal to identify and correct design and procedural problems with the proposed methods before resources were expended for the larger DSM-5 Field Trials. Results allowed for the refinement of the protocols, procedures, and measures, which facilitated recruitment, implementation, and completion of the DSM-5 Field Trials. These results highlight the benefits of pilot studies in planning large multisite studies. PMID:24615761
[Indication for antimycotic therapy for tracheobronchial candidosis under artificial ventilation].
Grossherr, M; Sedemund-Adib, Beate; Klotz, K-F
2005-01-01
Tracheobronchial candidosis is an impetuous complication in intensive care medicine. This article presents a concept to compare diagnostic procedure, Candida species and resistant species of different intensive care units with each other. This concept should encourage bench marking between similar intensive care units. The report and retrospective analysis of the intensive care course offer the opportunity to reflect own decisions and to adjust them to the current therapy strategies. Both procedures should improve the antimycotic therapy for intensive care units and should avoid the occurrence of resistant species. Candida species are often detected in the respiratory system of ventilated patients in intensive care, but this alone is no indication for antimycotic therapy. A strict retention is recommended, but this retention is diminished by an unclear infection, critical situation of the patient in the case of multiple organ failure, additional infection and long term ventilation. A therapy strategy for individual situations should be established and a close diagnostic procedure should be performed. A positive blood culture or detection of Candida species in two or more diagnostic materials indicate an early antimycotic therapy.
Ong, Jason J; Fu, Hongyun; Smith, M Kumi; Tucker, Joseph D
2018-05-01
Syphilis is an important sexually transmitted infection (STI). Despite inexpensive and effective treatment, few key populations receive syphilis testing. Innovative strategies are needed to increase syphilis testing among key populations. Areas covered: This scoping review focused on strategies to increase syphilis testing in key populations (men who have sex with men (MSM), sex workers, people who use drugs, transgender people, and incarcerated individuals). Expert commentary: We identified many promising syphilis testing strategies, particularly among MSM. These innovations are separated into diagnostic, clinic-based, and non-clinic based strategies. In terms of diagnostics, self-testing, dried blood spots, and point-of-care testing can decentralize syphilis testing. Effective syphilis self-testing pilots suggest the need for further attention and research. In terms of clinic-based strategies, modifying default clinical procedures can nudge physicians to more frequently recommend syphilis testing. In terms of non-clinic based strategies, venue-based screening (e.g. in correctional facilities, drug rehabilitation centres) and mobile testing units have been successfully implemented in a variety of settings. Integration of syphilis with HIV testing may facilitate implementation in settings where individuals have increased sexual risk. There is a strong need for further syphilis testing research and programs.
Web-based video monitoring of CT and MRI procedures
NASA Astrophysics Data System (ADS)
Ratib, Osman M.; Dahlbom, Magdalena; Kho, Hwa T.; Valentino, Daniel J.; McCoy, J. Michael
2000-05-01
A web-based video transmission of images from CT and MRI consoles was implemented in an Intranet environment for real- time monitoring of ongoing procedures. Images captured from the consoles are compressed to video resolution and broadcasted through a web server. When called upon, the attending radiologists can view these live images on any computer within the secured Intranet network. With adequate compression, these images can be displayed simultaneously in different locations at a rate of 2 to 5 images/sec through standard LAN. The quality of the images being insufficient for diagnostic purposes, our users survey showed that they were suitable for supervising a procedure, positioning the imaging slices and for routine quality checking before completion of a study. The system was implemented at UCLA to monitor 9 CTs and 6 MRIs distributed in 4 buildings. This system significantly improved the radiologists productivity by saving precious time spent in trips between reading rooms and examination rooms. It also improved patient throughput by reducing the waiting time for the radiologists to come to check a study before moving the patient from the scanner.
[Hepatocellular tumours in noncirrhotic liver tissue].
Goltz, D; Fischer, H-P
2015-11-01
In recent years, the spectrum of tissue-based diagnostics of hepatocellular tumours has changed due to novel molecular pathological findings. Innovative radiographics filter out small lesions and ambiguous tumours for bioptical sampling. The spectrum of these tumours includes hepatocellular carcinoma, hepatocellular adenomas, focal nodular hyperplasia and macroregenerative nodules. Primarily, morphological analysis should identify the dignity of a lesion. After exclusion of HCC and reactive liver cell nodules, hepatocellular adenomas should be further subclassified based on immunohistochemical/molecular pathological criteria according to the WHO classification of liver tumours. This procedure provides significant additional information regarding the prognosis and therapeutic implications of hepatocellular adenomas.
The influence of CT based attenuation correction on PET/CT registration: an evaluation study
NASA Astrophysics Data System (ADS)
Yaniv, Ziv; Wong, Kenneth H.; Banovac, Filip; Levy, Elliot; Cleary, Kevin
2007-03-01
We are currently developing a PET/CT based navigation system for guidance of biopsies and radiofrequency ablation (RFA) of early stage hepatic tumors. For these procedures, combined PET/CT data can potentially improve current interventions. The diagnostic efficacy of biopsies can potentially be improved by accurately targeting the region within the tumor that exhibits the highest metabolic activity. For RFA procedures the system can potentially enable treatment of early stage tumors, targeting tumors before structural abnormalities are clearly visible on CT. In both cases target definition is based on the metabolic data (PET), and navigation is based on the spatial data (CT), making the system highly dependent upon accurate spatial alignment between these data sets. In our institute all clinical data sets include three image volumes: one CT, and two PET volumes, with and without CT-based attenuation correction. This paper studies the effect of the CT-based attenuation correction on the registration process. From comparing the pairs of registrations from five data sets we observe that the point motion magnitude difference between registrations is on the same scale as the point motion magnitude in each one of the registrations, and that visual inspection cannot identify this discrepancy. We conclude that using non-rigid registration to align the PET and CT data sets is too variable, and most likely does not provide sufficient accuracy for interventional procedures.
Corona-Strauss, Farah I; Delb, Wolfgang; Schick, Bernhard; Strauss, Daniel J
2010-01-01
Auditory Brainstem Responses (ABRs) are used as objective method for diagnostics and quantification of hearing loss. Many methods for automatic recognition of ABRs have been developed, but none of them include the individual measurement setup in the analysis. The purpose of this work was to design a fast recognition scheme for chirp-evoked ABRs that is adjusted to the individual measurement condition using spontaneous electroencephalographic activity (SA). For the classification, the kernel-based novelty detection scheme used features based on the inter-sweep instantaneous phase synchronization as well as energy and entropy relations in the time-frequency domain. This method provided SA discrimination from stimulations above the hearing threshold with a minimum number of sweeps, i.e., 200 individual responses. It is concluded that the proposed paradigm, processing procedures and stimulation techniques improve the detection of ABRs in terms of the degree of objectivity, i.e., automation of procedure, and measurement time.
Sehgal, Inderpaul Singh; Dhooria, Sahajal; Aggarwal, Ashutosh Nath; Agarwal, Ritesh
2018-04-01
Whether the use of rapid on-site cytologic evaluation (ROSE) increases the diagnostic yield of transbronchial needle aspiration (TBNA) remains unclear. This article is a systematic review of studies describing the utility of ROSE in subjects undergoing TBNA. The study included a systematic review of the PubMed, Embase, and Scopus databases for randomized controlled trials investigating the diagnostic yield of conventional transbronchial needle aspiration (c-TBNA) or endobronchial ultrasound (EBUS)-TBNA, with or without ROSE, in subjects with mediastinal lymphadenopathy. Five studies (618 subjects; two EBUS-TBNA, two c-TBNA, and one both) were identified. Overall, the studies were of good quality. The pooled risk difference (95% CI) of the diagnostic yield of EBUS-TBNA and c-TBNA was 0.04 (-0.01 to 0.09) and 0.12 (-0.08 to 0.33), respectively, suggesting no added benefit with ROSE. The use of ROSE during EBUS-TBNA (but not c-TBNA) resulted in significantly fewer needle passes (mean difference [95% CI], -1.1 [-2.2 to -0.005]; P < .001). There was no difference in the procedure time during EBUS-TBNA. The complication rate was significantly lower (OR [95% CI], 0.26 [0.10 to 0.71]; P = .009) when ROSE was used during c-TBNA due to fewer additional procedures required to make a diagnosis. There was evidence of heterogeneity in the studies involving c-TBNA but not EBUS-TBNA. There was no publication bias. The use of ROSE neither improved the diagnostic yield nor reduced the procedure time during TBNA. However, the use of ROSE was associated with fewer number of needle passes during EBUS-TBNA and overall lower requirement for additional bronchoscopy procedures during TBNA to make a final diagnosis. PROSPERO; No.: CRD42017058937; URL: www.crd.york.ac.uk/prospero/. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Mishlanov, V Yu; Katkova, A V; Dugina, A A; Kuznetzova, V D; Tepanyan, A T; Zhygulev, A N
The aim of the study was to estimate clinical efficiency of the interactive automatic program of digestive system diseases diagnostics "Electronic policlinic". Material was presented by 22 patients with different gastroenterological diseases (duodenal ulcer, chronical gastritis, chronical pancreatitis) and the comparative group consisted of 20 healthy people. The plan of the research included the interactive questionnaire using diagnostic module digestive system diseases of the digestive system of the automated program "Electronic policlinic" (Certificate No. 2012614202 from 12.05.12) posted on the Internet (http://klinikcity.ru). For the purpose of verification of diagnosis patients underwent fibrogastroduodenoscopy, ultrasound examination of abdominal cavity organs, CT scan, sigmoidoscopy, colonoscopy, barium enema. As the result of the study there were showed that interactive automated system was able to reveal 85,7% of patients with chronical gastritis, duodenal ulcer and chronical pancreatitis and 75% of patients with colonopathy. The specify of diagnostic procedure was 80% in the first case and 100% in the second. Prevalence of digestive system diseases basic symptoms was studied too. The conclusion of the study demonstrated interactive questionnaire good ability in preliminary digestive problem patient examination procedure for individual diagnostic plan making.
Vermet, Shannon; McGinnis, Karen; Boodham, Melissa; Gleberzon, Brian J.
2010-01-01
Purpose: The objective of this study was to determine to what extent the diagnostic and therapeutic procedures taught in the undergraduate program used for patients with lumbopelvic conditions are expected to be utilized by students during their clinical internship program at Canadian Memorial Chiropractic College or are being used by the clinical faculty. Methods: A confidential survey was distributed to clinical faculty at the college. It consisted of a list of diagnostic and therapeutic procedures used for lumbopelvic conditions taught at that college. Clinicians were asked to indicate the frequency with which they performed or they required students to perform each item. Results: Seventeen of 23 clinicians responded. The following procedures were most likely required to be performed by clinicians: posture; ranges of motion; lower limb sensory, motor, and reflex testing; and core orthopedic tests. The following were less likely to be required to be performed: Waddell testing, Schober's test, Gillet tests, and abdominal palpation. Students were expected to perform (or clinicians performed) most of the mobilization (in particular, iliocostal, iliotransverse, and iliofemoral) and spinal manipulative therapies (in particular, the procedures referred to as the lumbar roll, lumbar pull/hook, and upper sacroiliac) taught at the college. Conclusion: This study suggests that there was considerable, but not complete, vertical integration between the undergraduate and clinical education program at this college. PMID:20480014
ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology.
Khong, P-L; Ringertz, H; Donoghue, V; Frush, D; Rehani, M; Appelgate, K; Sanchez, R
2013-04-01
Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients. Copyright © 2012. Published by Elsevier Ltd.
Automated working distance adjustment for a handheld OCT-Laryngoscope
NASA Astrophysics Data System (ADS)
Donner, Sabine; Bleeker, Sebastian; Ripken, Tammo; Krueger, Alexander
2014-03-01
Optical coherence tomography (OCT) is an imaging technique which enables diagnosis of vocal cord tissue structure by non-contact optical biopsies rather than invasive tissue biopsies. For diagnosis on awake patients OCT was adapted to a rigid indirect laryngoscope. The working distance must match the probe-sample distance, which varies from patient to patient. Therefore the endoscopic OCT sample arm has a variable working distance of 40 mm to 80 mm. The current axial position is identified by automated working distance adjustments based on image processing. The OCT reference plane and the focal plane of the sample arm are moved according to position errors. Repeated position adjustment during the whole diagnostic procedure keeps the tissue sample at the optimal axial position. The auto focus identifies and adjusts the working distance within the range of 50 mm within a maximum time of 2.7 s. Continuous image stabilisation reduces axial sample movement within the sampling depth for handheld OCT scanning. Rapid autofocus reduces the duration of the diagnostic procedure and axial position stabilisation eases the use of the OCT laryngoscope. Therefore this work is an important step towards the integration of OCT into indirect laryngoscopes.
Diagnostic radiograph based 3D bone reconstruction framework: application to the femur.
Gamage, P; Xie, S Q; Delmas, P; Xu, W L
2011-09-01
Three dimensional (3D) visualization of anatomy plays an important role in image guided orthopedic surgery and ultimately motivates minimally invasive procedures. However, direct 3D imaging modalities such as Computed Tomography (CT) are restricted to a minority of complex orthopedic procedures. Thus the diagnostics and planning of many interventions still rely on two dimensional (2D) radiographic images, where the surgeon has to mentally visualize the anatomy of interest. The purpose of this paper is to apply and validate a bi-planar 3D reconstruction methodology driven by prominent bony anatomy edges and contours identified on orthogonal radiographs. The results obtained through the proposed methodology are benchmarked against 3D CT scan data to assess the accuracy of reconstruction. The human femur has been used as the anatomy of interest throughout the paper. The novelty of this methodology is that it not only involves the outer contours of the bony anatomy in the reconstruction but also several key interior edges identifiable on radiographic images. Hence, this framework is not simply limited to long bones, but is generally applicable to a multitude of other bony anatomies as illustrated in the results section. Copyright © 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Wilson, Robert H.; Chandra, Malavika; Scheiman, James; Simeone, Diane; McKenna, Barbara; Purdy, Julianne; Mycek, Mary-Ann
2009-02-01
Pancreatic adenocarcinoma has a five-year survival rate of only 4%, largely because an effective procedure for early detection has not been developed. In this study, mathematical modeling of reflectance and fluorescence spectra was utilized to quantitatively characterize differences between normal pancreatic tissue, pancreatitis, and pancreatic adenocarcinoma. Initial attempts at separating the spectra of different tissue types involved dividing fluorescence by reflectance, and removing absorption artifacts by applying a "reverse Beer-Lambert factor" when the absorption coefficient was modeled as a linear combination of the extinction coefficients of oxy- and deoxy-hemoglobin. These procedures demonstrated the need for a more complete mathematical model to quantitatively describe fluorescence and reflectance for minimally-invasive fiber-based optical diagnostics in the pancreas.
Van Praag, H M
2001-05-01
A new subtype of depression is proposed, named: anxiety/aggression-driven depression. The psychopathological, psychopharmacological and biochemical evidence on which this construct is based, is being discussed. Selective postsynaptic 5-HT1A agonists together with CRH and/or cortisol antagonists are hypothesized to be a specific biological treatment for this depression type, in conjunction with psychological interventions to raise the stressor-threshold and to increase coping skills. The development of this depression construct has been contingent on the introduction of two new diagnostic procedures, called functionalization and verticalization of psychiatric diagnosis. These procedures are explained and it is stressed that they are essential to psychiatric diagnosing, in order to put this process on a scientific footing.
Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corey, J.P.; Liudahl, J.J.; Young, S.A.
1991-03-01
The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician.
Video integrated measurement system. [Diagnostic display devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spector, B.; Eilbert, L.; Finando, S.
A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides anmore » innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.« less
Vesiculo-Bullous Disorders of the Neonate
McKay, Roberta M.
1987-01-01
This is the first of three articles which outline the diagnoses to be considered when vesiculo-bullous lesions are identified in the neonate, children, and adults. This paper presents a brief sketch of blistering disorders which may occur during the first few weeks of life. Vesiculo-bullous lesions in the neonate may represent benign, infectious, genetic, or life-threatening disorders. Early recognition, appropriate diagnostic procedures, and specific therapeutic interventions can be vital in reducing potential morbidity and mortality. General guidelines for diagnostic procedures and therapeutic interventions are discussed, along with some of the newer etiologic and epidemiologic concepts. PMID:21263952
Improving safety in CT through the use of educational media.
Mattingly, Melisa
2011-01-01
With a grant from the AHRA and Toshiba Putting Patients First program, Community Hospital in Indianapolis, IN set out to reduce the need for patient sedation, mechanical restraint, additional radiation dosage,and repeat procedures for pediatric patients. An online video was produced to educate pediatric patients and their caregivers about the diagnostic imaging process enabling them to be more comfortable and compliant during the procedure. Early information and results indicate a safer experience for the patient.The goal is for the video to become a new best practice tool for improving patient care and safety in diagnostic imaging.
Automatic Generation of Conditional Diagnostic Guidelines.
Baldwin, Tyler; Guo, Yufan; Syeda-Mahmood, Tanveer
2016-01-01
The diagnostic workup for many diseases can be extraordinarily nuanced, and as such reference material text often contains extensive information regarding when it is appropriate to have a patient undergo a given procedure. In this work we employ a three task pipeline for the extraction of statements indicating the conditions under which a procedure should be performed, given a suspected diagnosis. First, we identify each instance in the text where a procedure is being recommended. Next we examine the context around these recommendations to extract conditional statements that dictate the conditions under which the recommendation holds. Finally, corefering recommendations across the document are linked to produce a full recommendation summary. Results indicate that each underlying task can be performed with above baseline performance, and the output can be used to produce concise recommendation summaries.
Combined use of videoendoscopy and X-ray imaging for improved monitoring of stenting application
NASA Astrophysics Data System (ADS)
Cysewska-Sobusiak, A. R.; Sowier, A.; Skrzywanek, P.
2005-09-01
The subject of this paper concerns advanced techniques of procedures and imaging used in minimally invasive surgery and in non-operable cases of the alimentary tract tumor therapy. Examples of videoendoscopy and X-ray imaging used for the application of stents (prostheses) and catheters allowing for the performance of diagnostic and endo-therapeutic procedures are described. The possibility was indicated to elaborate a new method of proceeding in tumor therapy in the patients for whom the methods used so far were ineffective. In the paper examples of combined imaging the application of metallic stents and plastic catheters allowing for the performance of diagnostic and therapeutic procedures are presented. The cases shown refer to tumor located in the esophagus and in the bile and pancreatic ducts.
A Review of Conventional PCR Assays for the Detection of Selected Phytopathogens of Wheat.
Kuzdraliński, Adam; Kot, Anna; Szczerba, Hubert; Nowak, Michał; Muszyńska, Marta
2017-01-01
Infection of phyllosphere (stems, leaves, husks, and grains) by pathogenic fungi reduces the wheat yield and grain quality. Detection of the main wheat pathogenic fungi provides information about species composition and allows effective and targeted plant treatment. Since conventional procedures for the detection of these organisms are unreliable and time consuming, diagnostic DNA-based methods are required. Nucleic acid amplification technologies are independent of the morphological and biochemical characteristics of fungi. Microorganisms do not need to be cultured. Therefore, a number of PCR-based methodologies have been developed for the identification of key pathogenic fungi, such as Fusarium spp., Puccinia spp., Zymoseptoria tritici, Parastagonospora nodorum, Blumeria graminis f. sp. tritici, and Pyrenophora tritici-repentis. This article reviews frequently used DNA regions for fungus identification and discusses already known PCR assays for detection of the aforementioned wheat pathogens. We demonstrate that PCR-based wheat pathogen identification assays require further research. In particular, the number of diagnostic tests for Fusarium graminearum, Puccinia spp., and P. tritici-repentis are insufficient. © 2017 S. Karger AG, Basel.
Electronic-nose devices - Potential for noninvasive early disease-detection applications
Alphus Dan Wilson
2017-01-01
Significant progress in the development of portable electronic devices is showing considerable promise to facilitate clinical diagnostic processes. The increasing global trend of shifts in healthcare policies and priorities toward shortening and improving the effectiveness of diagnostic procedures by utilizing non-invasive methods should provide multiple benefits of...
Federal Guidance Report No. 14 provides federal facilities that use diagnostic and interventional x-ray equipment with updated recommendations for keeping doses as low as reasonably achievable without compromising the quality of patient care, This guidance is an update of Federal...
21 CFR 892.1850 - Radiographic film cassette.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...
21 CFR 892.1850 - Radiographic film cassette.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...
21 CFR 892.1850 - Radiographic film cassette.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...
21 CFR 892.1850 - Radiographic film cassette.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic film cassette. 892.1850 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1850 Radiographic film cassette. (a) Identification. A radiographic film cassette is a device intended for use during diagnostic x-ray procedures to...
21 CFR 864.9600 - Potentiating media for in vitro diagnostic use.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Manufacture Blood and Blood Products § 864.9600 Potentiating media for in vitro diagnostic use. (a... to suspend red cells and to enhance cell reactions for antigen-antibody testing. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart...
21 CFR 864.9600 - Potentiating media for in vitro diagnostic use.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Manufacture Blood and Blood Products § 864.9600 Potentiating media for in vitro diagnostic use. (a... to suspend red cells and to enhance cell reactions for antigen-antibody testing. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart...
21 CFR 864.9600 - Potentiating media for in vitro diagnostic use.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Manufacture Blood and Blood Products § 864.9600 Potentiating media for in vitro diagnostic use. (a... to suspend red cells and to enhance cell reactions for antigen-antibody testing. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart...
21 CFR 864.9600 - Potentiating media for in vitro diagnostic use.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Manufacture Blood and Blood Products § 864.9600 Potentiating media for in vitro diagnostic use. (a... to suspend red cells and to enhance cell reactions for antigen-antibody testing. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart...
21 CFR 864.9600 - Potentiating media for in vitro diagnostic use.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Manufacture Blood and Blood Products § 864.9600 Potentiating media for in vitro diagnostic use. (a... to suspend red cells and to enhance cell reactions for antigen-antibody testing. (b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart...
The Development of a Vocational Diagnostic Program. Interim Report.
ERIC Educational Resources Information Center
Barnard, William W.
A five-phased project is described which was designed to develop more specific diagnostic procedures and instrumentation that would allow both the vocational counselor and the prospective student to determine more effectively specific occupational programs and occupational objectives for education at the postsecondary level. Phases of the project…
Llama medicine. Physical examination, restraint and handling.
Fowler, M
1989-03-01
Llamas are generally docile, easily handled domestic animals. Special chutes have been designed for safe, efficient restraint for examination and diagnostic procedures, most of which are commonly performed on other species. Anatomic differences make some of these procedures unique to the llama.
Students' understandings of electrochemistry
NASA Astrophysics Data System (ADS)
O'Grady-Morris, Kathryn
Electrochemistry is considered by students to be a difficult topic in chemistry. This research was a mixed methods study guided by the research question: At the end of a unit of study, what are students' understandings of electrochemistry? The framework of analysis used for the qualitative and quantitative data collected in this study was comprised of three categories: types of knowledge used in problem solving, levels of representation of knowledge in chemistry (macroscopic, symbolic, and particulate), and alternative conceptions. Although individually each of the three categories has been reported in previous studies, the contribution of this study is the inter-relationships among them. Semi-structured, task-based interviews were conducted while students were setting up and operating electrochemical cells in the laboratory, and a two-tiered, multiple-choice diagnostic instrument was designed to identify alternative conceptions that students held at the end of the unit. For familiar problems, those involving routine voltaic cells, students used a working-forwards problem-solving strategy, two or three levels of representation of knowledge during explanations, scored higher on both procedural and conceptual knowledge questions in the diagnostic instrument, and held fewer alternative conceptions related to the operation of these cells. For less familiar problems, those involving non-routine voltaic cells and electrolytic cells, students approached problem-solving with procedural knowledge, used only one level of representation of knowledge when explaining the operation of these cells, scored higher on procedural knowledge than conceptual knowledge questions in the diagnostic instrument, and held a greater number of alternative conceptions. Decision routines that involved memorized formulas and procedures were used to solve both quantitative and qualitative problems and the main source of alternative conceptions in this study was the overgeneralization of theory related to the particulate level of representation of knowledge. The findings from this study may contribute further to our understanding of students' conceptions in electrochemistry. Furthermore, understanding the influence of the three categories in the framework of analysis and their inter-relationships on how students make sense of this field may result in a better understanding of classroom practice that could promote the acquisition of conceptual knowledge --- knowledge that is "rich in relationships".
Coronary angiogram video compression for remote browsing and archiving applications.
Ouled Zaid, Azza; Fradj, Bilel Ben
2010-12-01
In this paper, we propose a H.264/AVC based compression technique adapted to coronary angiograms. H.264/AVC coder has proven to use the most advanced and accurate motion compensation process, but, at the cost of high computational complexity. On the other hand, analysis of coronary X-ray images reveals large areas containing no diagnostically important information. Our contribution is to exploit the energy characteristics in slice equal size regions to determine the regions with relevant information content, to be encoded using the H.264 coding paradigm. The others regions, are compressed using fixed block motion compensation and conventional hard-decision quantization. Experiments have shown that at the same bitrate, this procedure reduces the H.264 coder computing time of about 25% while attaining the same visual quality. A subjective assessment, based on the consensus approach leads to a compression ratio of 30:1 which insures both a diagnostic adequacy and a sufficient compression in regards to storage and transmission requirements. Copyright © 2010 Elsevier Ltd. All rights reserved.
Engelhardt, Eliasz; Tocquer, Carla; André, Charles; Moreira, Denise Madeira; Okamoto, Ivan Hideyo; Cavalcanti, José Luiz de Sá
2011-01-01
Vascular dementia (VaD) is the most prevalent form of secondary dementia and the second most common of all dementias. The present paper aims to define guidelines on the basic principles for treating patients with suspected VaD (and vascular cognitive impairment - no dementia) using an evidence-based approach. The material was retrieved and selected from searches of databases (Medline, Scielo, Lilacs), preferentially from the last 15 years, to propose a systematic way to assess cognition, function and behavior, and disease severity staging, with instruments adapted for our milieu, and diagnosis disclosure. The present proposal contributes to the definition of standard diagnostic criteria for VaD based on various levels of evidence. It is noteworthy that only around half of the population of patients with vascular cognitive impairment present with dementia, which calls for future proposals defining diagnostic criteria and procedures for this condition. PMID:29213753
Current use and future perspectives of diagnostic and therapeutic lasers in Oral Medicine.
Maia, A M A; Barkokebas, A; Pires, A P; Barros, L F; Carvalho, A A T; Leão, J C
2008-10-01
Several diagnostic and therapeutic methods are based on the optical properties of lasers. In therapeutic applications, laser light is absorbed in a specific manner, whereas light is scattered, reflected, or transmitted from different structures. Improvements in laser technology allow new procedures and broaden the scope of applications for both diagnosis and therapy. The focus of laser application in Oral Medicine diagnosis should be early detection of oral squamous cell carcinoma. Novel modalities for the detection of oral malignancy are urgently needed, while others must be continuously improved. Optical coherence tomography and laser-induced fluorescence spectroscopy are currently being studied. In addition to diagnosis of non-malignant lesions, laser therapy has been used based upon the biological reactions and molecular wound healing mechanisms as an alternative for the treatment of a variety of oral soft tissue lesions. The aim of the present article is to review current knowledge and future perspectives of lasers in Oral Medicine.
Effectiveness of rapid prescreening and 10% rescreening in liquid-based Papanicolaou testing.
Currens, Heather S; Nejkauf, Katharine; Wagner, Lynn; Raab, Stephen S
2012-01-01
Although rapid prescreening (RPS) has been shown to be an effective quality control procedure for detecting false-negative conventional Papanicolaou (Pap) tests, RPS has not been widely implemented in the United States. In our laboratory, cytotechnologists performed RPS in 3,567 liquid-based Pap tests: 1,911 SurePath (BD Diagnostics-TriPath, Burlington, NC) preparations that were manually screened and 1,656 ThinPrep Pap tests (Hologic, Bedford, MA) that were imaged using the ThinPrep Imaging System (Hologic). We compared the sensitivity of RPS, 10% rescreening (R-10%), and routine screening (RS). In contrast with previously published findings, we found that RS + RPS did not improve screening sensitivity compared with RS + R-10%. These results support the following hypotheses: (1) Higher baseline RS sensitivity as a result of Pap test diagnoses standardization implemented for quality improvement purposes decreases the performance impact of RPS. (2) R-10% and RPS quality assurance methods detect diagnostic failures caused by different types of cognitive errors.
The diagnostic accuracy of dermoscopy for scabies.
Park, Ju Hyuk; Kim, Chul Woo; Kim, Sang Seok
2012-05-01
Scabies is a contagious skin infestation characterized clinically by nocturnal pruritus, visible burrows and contagiousness. Dermoscopy has been suggested as an alternative for diagnosing scabies. But, there have been few well-designed studies evaluating the diagnostic accuracy of dermoscopy. We tried to confirm the diagnostic accuracy of dermoscopy for diagnosing scabies. We also tried to demonstrate specific circumstances in which dermoscopic identification of mites ("with dermoscopy") is more useful in diagnosing scabies, and to identify the specific clinical findings that could be used as a possible marker in diagnosing scabies. We compared the scraping procedure "with dermoscopy" and "without it" in 49 patients, measuring the duration and outcome of each procedure. Also, we tried to find the specific clinical factors associated with our objects. The skin scraping "with dermoscopy" was superior to "without it" with respect to the duration and accuracy of the procedure. A history of previous steroid treatment was associated with the superiority of dermoscopy. The correlation between the presence of visible burrows and the positive outcomes of "with dermoscopy" was statistically significant. Skin scraping with dermoscopy is implicated as the diagnostic method of choice for scabies at the present time. Dermoscopy is especially useful in diagnosis of incognito scabies. In addition, the presence of visible burrows could be a reliable positive marker of scabies in the absence of dermoscopy or microscopy data.
Wogu, M N; Nduka, F O
2018-01-01
The World Health Organization's policy on laboratory test of all suspected malaria cases before treatment has not yielded significant effects in several rural areas of Sub-Saharan Africa due to inadequate diagnostic infrastructure, leading to high morbidity and mortality rates. A cross-sectional randomized study was conducted to evaluate the validity of clinical malaria diagnosis through comparison with microscopy and rapid diagnostic test kits (RDTs) using 1000 consenting outpatients of a tertiary hospital in Nigeria. Physicians conducted clinical diagnosis, and blood samples were collected through venous procedure and analyzed for malaria parasites using Giemsa microscopy and RDT kits. Microscopy was considered the diagnostic "gold standard" and all data obtained were statistically analyzed using Chi-square test with a P value <0.05 considered significant. Malaria prevalence values of 20.1%, 43.1%, and 29.7% were obtained for clinical diagnosis, microscopy, and RDTs, respectively ( P < 0.05). Values of 47.2%, 95.9%, and 77.8% were obtained for sensitivity, specificity, and diagnostic accuracy, respectively, in clinical diagnosis, while RDTs had sensitivity, specificity, and diagnostic accuracy values of 73.7%, 97.3%, and 88.3%, respectively, when compared to microscopy ( P < 0.05). Clinical diagnosed malaria cases should be confirmed with a parasite-based laboratory diagnosis and more qualitative research is needed to explore why clinicians still use clinical diagnosis despite reported cases of its ineffectiveness.
Delfiner, Matthew S; Martinez, Luis R; Pavia, Charles S
2016-01-01
Laboratory diagnostic tests have an essential role in patient care, and the increasing number of medical and health professions schools focusing on teaching laboratory medicine to pre-clinical students reflects this importance. However, data validating the pedagogical methods that best influence students' comprehension and interpretation of diagnostic tests have not been well described. The Gram stain is a simple yet significant and frequently used diagnostic test in the clinical setting that helps classify bacteria into two major groups, Gram positive and negative, based on their cell wall structure. We used this technique to assess which educational strategies may improve students' learning and competency in medical diagnostic techniques. Hence, in this randomized controlled study, we compared the effectiveness of several educational strategies (e.g. workshop, discussion, or lecture) in first year medical students' competency in comprehension and interpretation of the Gram stain procedure. We demonstrated that a hands-on practical workshop significantly enhances students' competency in memorization and overall comprehension of the technique. Interestingly, most students irrespective of their cohort showed difficulty in answering Gram stain-related analytical questions, suggesting that more emphasis should be allocated by the instructors to clearly explain the interpretation of the diagnostic test results to students in medical and health professional schools. This proof of principle study highlights the need of practical experiences on laboratory medical techniques during pre-clinical training to facilitate future medical doctors' and healthcare professionals' basic understanding and competency in diagnostic testing for better patient care.
Pimentel, Mark; Purdy, Chris; Magar, Raf; Rezaie, Ali
2016-07-01
A high incidence of irritable bowel syndrome (IBS) is associated with significant medical costs. Diarrhea-predominant IBS (IBS-D) is diagnosed on the basis of clinical presentation and diagnostic test results and procedures that exclude other conditions. This study was conducted to estimate the potential cost savings of a novel IBS diagnostic blood panel that tests for the presence of antibodies to cytolethal distending toxin B and anti-vinculin associated with IBS-D. A cost-minimization (CM) decision tree model was used to compare the costs of a novel IBS diagnostic blood panel pathway versus an exclusionary diagnostic pathway (ie, standard of care). The probability that patients proceed to treatment was modeled as a function of sensitivity, specificity, and likelihood ratios of the individual biomarker tests. One-way sensitivity analyses were performed for key variables, and a break-even analysis was performed for the pretest probability of IBS-D. Budget impact analysis of the CM model was extrapolated to a health plan with 1 million covered lives. The CM model (base-case) predicted $509 cost savings for the novel IBS diagnostic blood panel versus the exclusionary diagnostic pathway because of the avoidance of downstream testing (eg, colonoscopy, computed tomography scans). Sensitivity analysis indicated that an increase in both positive likelihood ratios modestly increased cost savings. Break-even analysis estimated that the pretest probability of disease would be 0.451 to attain cost neutrality. The budget impact analysis predicted a cost savings of $3,634,006 ($0.30 per member per month). The novel IBS diagnostic blood panel may yield significant cost savings by allowing patients to proceed to treatment earlier, thereby avoiding unnecessary testing. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C
2015-10-01
The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.
Quantitative optical diagnostics in pathology recognition and monitoring of tissue reaction to PDT
NASA Astrophysics Data System (ADS)
Kirillin, Mikhail; Shakhova, Maria; Meller, Alina; Sapunov, Dmitry; Agrba, Pavel; Khilov, Alexander; Pasukhin, Mikhail; Kondratieva, Olga; Chikalova, Ksenia; Motovilova, Tatiana; Sergeeva, Ekaterina; Turchin, Ilya; Shakhova, Natalia
2017-07-01
Optical coherence tomography (OCT) is currently actively introduced into clinical practice. Besides diagnostics, it can be efficiently employed for treatment monitoring allowing for timely correction of the treatment procedure. In monitoring of photodynamic therapy (PDT) traditionally employed fluorescence imaging (FI) can benefit from complementary use of OCT. Additional diagnostic efficiency can be derived from numerical processing of optical diagnostics data providing more information compared to visual evaluation. In this paper we report on application of OCT together with numerical processing for clinical diagnostic in gynecology and otolaryngology, for monitoring of PDT in otolaryngology and on OCT and FI applications in clinical and aesthetic dermatology. Image numerical processing and quantification provides increase in diagnostic accuracy. Keywords: optical coherence tomography, fluorescence imaging, photod
[Interventional radiology: current problems and new directions].
Santos Martín, E; Crespo Vallejo, E
2014-01-01
In recent years, vascular and interventional radiology has become one of the fastest growing diagnostic and therapeutic specialties. This growth has been based on a fundamental concept: performing minimally invasive procedures under imaging guidance. This attractive combination has led to the interest of professionals from other clinical specialties outside radiology in performing this type of intervention. The future of vascular and interventional radiology, although uncertain, must be linked to clinical practice and multidisciplinary teamwork. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
Implementation of an Algorithm for Prosthetic Joint Infection: Deviations and Problems.
Mühlhofer, Heinrich M L; Kanz, Karl-Georg; Pohlig, Florian; Lenze, Ulrich; Lenze, Florian; Toepfer, Andreas; von Eisenhart-Rothe, Ruediger; Schauwecker, Johannes
The outcome of revision surgery in arthroplasty is based on a precise diagnosis. In addition, the treatment varies based on whether the prosthetic failure is caused by aseptic or septic loosening. Algorithms can help to identify periprosthetic joint infections (PJI) and standardize diagnostic steps, however, algorithms tend to oversimplify the treatment of complex cases. We conducted a process analysis during the implementation of a PJI algorithm to determine problems and deviations associated with the implementation of this algorithm. Fifty patients who were treated after implementing a standardized algorithm were monitored retrospectively. Their treatment plans and diagnostic cascades were analyzed for deviations from the implemented algorithm. Each diagnostic procedure was recorded, compared with the algorithm, and evaluated statistically. We detected 52 deviations while treating 50 patients. In 25 cases, no discrepancy was observed. Synovial fluid aspiration was not performed in 31.8% of patients (95% confidence interval [CI], 18.1%-45.6%), while white blood cell counts (WBCs) and neutrophil differentiation were assessed in 54.5% of patients (95% CI, 39.8%-69.3%). We also observed that the prolonged incubation of cultures was not requested in 13.6% of patients (95% CI, 3.5%-23.8%). In seven of 13 cases (63.6%; 95% CI, 35.2%-92.1%), arthroscopic biopsy was performed; 6 arthroscopies were performed in discordance with the algorithm (12%; 95% CI, 3%-21%). Self-critical analysis of diagnostic processes and monitoring of deviations using algorithms are important and could increase the quality of treatment by revealing recurring faults.
Preoperative magnetic resonance imaging protocol for endoscopic cranial base image-guided surgery.
Grindle, Christopher R; Curry, Joseph M; Kang, Melissa D; Evans, James J; Rosen, Marc R
2011-01-01
Despite the increasing utilization of image-guided surgery, no radiology protocols for obtaining magnetic resonance (MR) imaging of adequate quality are available in the current literature. At our institution, more than 300 endonasal cranial base procedures including pituitary, extended pituitary, and other anterior skullbase procedures have been performed in the past 3 years. To facilitate and optimize preoperative evaluation and assessment, there was a need to develop a magnetic resonance protocol. Retrospective Technical Assessment was performed. Through a collaborative effort between the otolaryngology, neurosurgery, and neuroradiology departments at our institution, a skull base MR image-guided (IGS) protocol was developed with several ends in mind. First, it was necessary to generate diagnostic images useful for the more frequently seen pathologies to improve work flow and limit the expense and inefficiency of case specific MR studies. Second, it was necessary to generate sequences useful for IGS, preferably using sequences that best highlight that lesion. Currently, at our institution, all MR images used for IGS are obtained using this protocol as part of preoperative planning. The protocol that has been developed allows for thin cut precontrast and postcontrast axial cuts that can be used to plan intraoperative image guidance. It also obtains a thin cut T2 axial series that can be compiled separately for intraoperative imaging, or may be fused with computed tomographic images for combined modality. The outlined protocol obtains image sequences effective for diagnostic and operative purposes for image-guided surgery using both T1 and T2 sequences. Copyright © 2011 Elsevier Inc. All rights reserved.
[New guidelines on chronic pancreatitis : interdisciplinary treatment strategies].
Lerch, M M; Bachmann, K A; Izbicki, J R
2013-02-01
Chronic pancreatitis is a common disorder associated with significant morbidity and mortality. Interdisciplinary consensus guidelines have recently updated the definitions and diagnostic criteria for chronic pancreatitis and provide a critical assessment of therapeutic procedures. Diagnostic imaging relies on endoscopic ultrasound (EUS) as the most sensitive technique, whereas computed tomography (CT) and magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) remain a frequent preoperative requirement. Endoscopic retrograde cholangiopancreatography (ERCP) is now used mostly as a therapeutic procedure except for the differential diagnosis of autoimmune pancreatitis. Complications of chronic pancreatitis, such as pseudocysts, duct stricture and intractable pain can be treated with endoscopic interventions as well as open surgery. In the treatment of pseudocysts endoscopic drainage procedures now prevail while pain treatment has greater long-term effectiveness following surgical procedures. Currently, endocopic as well as surgical treatment of chronic pancreatitis require an ever increasing degree of technical and medical expertise and are provided increasingly more often by interdisciplinary centres. Surgical treatment is superior to interventional therapy regarding the outcome of pain control and duodenum-preserving pancreatic head resection is presently the surgical procedure of choice.
Pleural procedures in the management of malignant effusions
Ferreiro, Lucía; Suárez-Antelo, Juan; Valdés, Luis
2017-01-01
Malignant pleural effusion (MPE) is common in clinical practice, and despite the existence of studies to guide clinical decisions, it often poses diagnostic and therapeutic dilemmas. Once it is diagnosed, median survival does not usually exceed 6 months. The management of these patients focuses on symptom relief since no treatments have been shown to increase survival to date. Conversely, poor management can shorten survival. The approach must be multidisciplinary and allow for individualized care. Initial diagnostic procedures should be minimally invasive and, according to the results and other factors, procedures of increasing complexity will be selecting. Likewise, the treatment of MPEs should be individualized according to factors such as type of tumor, patient functional status, means available, benefits of each procedure, or life expectancy. Currently, treatment seems to tend toward less interventional approaches, in which patients can be managed on an outpatient basis, thus minimizing both the discomfort that more aggressive approaches involve and the costs of care associated with this disease. This article reviews the pleural procedures employed in the management of MPEs with special emphasis on the indication for each one, its usefulness, benefits, and complications. PMID:28197215
Patchwork diagnoses: the production of coherence, uncertainty, and manageable bodies.
Gardner, John; Dew, Kevin; Stubbe, Maria; Dowell, Tony; Macdonald, Lindsay
2011-09-01
Using a material semiotics methodology, this paper explores the link between diagnostic practices, patient awareness of the body, and biopolitical governance. We collected video and audio recordings of a patient with chest pain involved in three medical interactions (a general practitioner [GP] consultation, an electrocardiogram stress test and a consultation with a cardiologist) in Wellington, New Zealand. Following the work of Annemarie Mol, we argue that each of these diagnostics interactions bring together a range of material and non-material entities that enact the body and disease. Consequently, we note how the diagnostic practices associated with cardiovascular medicine enable and prompt an awareness of the body based on uncertainty, and thus promotes the self-management of cardiac health and risk. This paper illustrates that a material semiotics methodology makes important contributions to the sociology of diagnosis. Firstly, it draws attention to the relationship between humans and material entities in rendering the body intelligible. Secondly, it illustrates that different diagnostic procedures can produce multiple, potentially conflicting, forms of self-awareness. Alongside these practices generating multiplicity, however, are those that presuppose and produce singularity and coherence. We illustrate how the cardiologist "patches" two potentially conflicting diagnoses together in order to provide a sense of coherence to the interactions. Thirdly, material semiotics illustrates how various diagnostic practices can reify risk, and produce bodies that lend themselves to particular forms of governance. Copyright © 2011 Elsevier Ltd. All rights reserved.
Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.
Alagrund, Katariina; Orpana, Arto K
2014-01-01
The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.
Spyropoulos, George; Kontakiotis, Theodoros; Spyratos, Dionysios; Iakovidis, Dimitrios; Zoglopitis, Fotis; Zarogoulidis, Konstantinos
2012-01-01
Background Thoracoscopy with local anesthesia or medical thoracoscopy is an invasive method which is rather valuable not only for the approach of undiagnosed exudative pleural effusions but also for the treatment of symptomatic malignant effusions with the conduct of pleurodesis. This is a review of those patients who underwent medical thoracoscopy in the period May 2011 to September 2012 in the Pulmonary Department the Aristotle University of Thessaloniki. Patients and methods Thirty nine thoracoscopies were conducted in our Department since May 2011. Twenty nine patients with cytological test negative for malignancy underwent diagnostic thoracoscopy. Eleven of those procedures were diagnostic and positive for malignancy, while 12 were non-diagnostic and 2 with limited evidence of malignancy. The biopsy results of 2 thoracoscopies showed granulomatous infection and other 2 nonspecific chronic inflammation. Out of all the diagnoses which were positive for malignancy, 2 were related to mesothelioma, 5 to adenocarcinoma (4 of them originated from lungs and one of unknown primary origin) while 1 patient was diagnosed with metastatic papillary adenocarcinoma originated from the thyroid and another one with lymphoma. There were also patients carrying diagnosed illness intending pleurodesis in cases of malignant recrudescent pleural effusions in mesothelioma, lung adenocarcinoma and biliary carcinoma who underwent thoracoscopy. Another patient with recrudescent pneumothorax underwent pleurodesis with talc. Results The major complications which emerged either during the procedure or after the thoracoscopy were two: one patient developed allergy in lidocaine intake for the local anesthesia having as a result to quit the procedure while another patient developed an empyema several weeks later. Conclusions Thoracoscopy with local anesthesia is a safe procedure, tolerable for the patient, which has a significant diagnostic value and only a small percentage of complications.
Lee, Jeong-Min; Kim, Myeong-Jin; Phongkitkarun, Sith; Sobhonslidsuk, Abhasnee; Holtorf, Anke-Peggy; Rinde, Harald; Bergmann, Karsten
2016-08-01
The effectiveness of treatment decisions and economic outcomes of using gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging (Gd-EOB-DTPA-MRI) were compared with extracellular contrast media-enhanced MRI (ECCM-MRI) and multi-detector computed tomography (MDCT) as initial procedures in patients with suspected hepatocellular carcinoma (HCC) in South Korea and Thailand. A decision-tree model simulated the clinical pathway for patients with suspected HCC from the first imaging procedure to a confirmed treatment decision. Input data (probabilities and resource consumptions) were estimated and validated by clinical experts. Costs for diagnostic alternatives and related treatment options were derived from published sources, taking into account both payer's and hospital's perspectives. All experts from Korea and Thailand agreed that Gd-EOB-DTPA-MRI yields the highest diagnostic certainty and minimizes the need for additional confirmatory diagnostic procedures in HCC. In Korea, from the payer's perspective, total cost was USD $3087/patient to reach a confirmed treatment decision using Gd-EOB-DTPA-MRI (vs $3205/patient for MDCT and $3403/patient for ECCM-MRI). From the hospital's perspective, Gd-EOB-DTPA-MRI incurred the lowest cost ($2289/patient vs $2320/patient and $2528/patient, respectively). In Thailand, Gd-EOB-DTPA-MRI was the least costly alternative for the payer ($702/patient vs $931/patient for MDCT and $873/patient for ECCM-MRI). From the hospital's perspective, costs were $1106/patient, $1178/patient, and $1087/patient for Gd-EOB-DTPA-MRI, MDCT, and ECCM-MRI, respectively. Gd-EOB-DTPA-MRI as an initial imaging procedure in patients with suspected HCC provides better diagnostic certainty and relevant statutory health insurance cost savings in Thailand and Korea, compared with ECCM-MRI and MDCT.
An illustration of new methods in machine condition monitoring, Part I: stochastic resonance
NASA Astrophysics Data System (ADS)
Worden, K.; Antoniadou, I.; Marchesiello, S.; Mba, C.; Garibaldi, L.
2017-05-01
There have been many recent developments in the application of data-based methods to machine condition monitoring. A powerful methodology based on machine learning has emerged, where diagnostics are based on a two-step procedure: extraction of damage-sensitive features, followed by unsupervised learning (novelty detection) or supervised learning (classification). The objective of the current pair of papers is simply to illustrate one state-of-the-art procedure for each step, using synthetic data representative of reality in terms of size and complexity. The first paper in the pair will deal with feature extraction. Although some papers have appeared in the recent past considering stochastic resonance as a means of amplifying damage information in signals, they have largely relied on ad hoc specifications of the resonator used. In contrast, the current paper will adopt a principled optimisation-based approach to the resonator design. The paper will also show that a discrete dynamical system can provide all the benefits of a continuous system, but also provide a considerable speed-up in terms of simulation time in order to facilitate the optimisation approach.
Diagnostic x-ray dosimetry using Monte Carlo simulation.
Ioppolo, J L; Price, R I; Tuchyna, T; Buckley, C E
2002-05-21
An Electron Gamma Shower version 4 (EGS4) based user code was developed to simulate the absorbed dose in humans during routine diagnostic radiological procedures. Measurements of absorbed dose using thermoluminescent dosimeters (TLDs) were compared directly with EGS4 simulations of absorbed dose in homogeneous, heterogeneous and anthropomorphic phantoms. Realistic voxel-based models characterizing the geometry of the phantoms were used as input to the EGS4 code. The voxel geometry of the anthropomorphic Rando phantom was derived from a CT scan of Rando. The 100 kVp diagnostic energy x-ray spectra of the apparatus used to irradiate the phantoms were measured, and provided as input to the EGS4 code. The TLDs were placed at evenly spaced points symmetrically about the central beam axis, which was perpendicular to the cathode-anode x-ray axis at a number of depths. The TLD measurements in the homogeneous and heterogenous phantoms were on average within 7% of the values calculated by EGS4. Estimates of effective dose with errors less than 10% required fewer numbers of photon histories (1 x 10(7)) than required for the calculation of dose profiles (1 x 10(9)). The EGS4 code was able to satisfactorily predict and thereby provide an instrument for reducing patient and staff effective dose imparted during radiological investigations.
Diagnostic x-ray dosimetry using Monte Carlo simulation
NASA Astrophysics Data System (ADS)
Ioppolo, J. L.; Price, R. I.; Tuchyna, T.; Buckley, C. E.
2002-05-01
An Electron Gamma Shower version 4 (EGS4) based user code was developed to simulate the absorbed dose in humans during routine diagnostic radiological procedures. Measurements of absorbed dose using thermoluminescent dosimeters (TLDs) were compared directly with EGS4 simulations of absorbed dose in homogeneous, heterogeneous and anthropomorphic phantoms. Realistic voxel-based models characterizing the geometry of the phantoms were used as input to the EGS4 code. The voxel geometry of the anthropomorphic Rando phantom was derived from a CT scan of Rando. The 100 kVp diagnostic energy x-ray spectra of the apparatus used to irradiate the phantoms were measured, and provided as input to the EGS4 code. The TLDs were placed at evenly spaced points symmetrically about the central beam axis, which was perpendicular to the cathode-anode x-ray axis at a number of depths. The TLD measurements in the homogeneous and heterogenous phantoms were on average within 7% of the values calculated by EGS4. Estimates of effective dose with errors less than 10% required fewer numbers of photon histories (1 × 107) than required for the calculation of dose profiles (1 × 109). The EGS4 code was able to satisfactorily predict and thereby provide an instrument for reducing patient and staff effective dose imparted during radiological investigations.
Diagnostic sensitivity of abdominal fat aspiration in cardiac amyloidosis
Quarta, Candida Cristina; Gonzalez-Lopez, Esther; Gilbertson, Janet A.; Botcher, Nichola; Rowczenio, Dorota; Petrie, Aviva; Rezk, Tamer; Youngstein, Taryn; Mahmood, Shameem; Sachchithanantham, Sajitha; Lachmann, Helen J.; Fontana, Marianna; Whelan, Carol J.; Wechalekar, Ashutosh D.; Hawkins, Philip N.; Gillmore, Julian D.
2017-01-01
Abstract Aims Congo red staining of an endomyocardial biopsy is the diagnostic gold-standard in suspected cardiac amyloidosis (CA), but the procedure is associated with the risk, albeit small, of serious complications, and delay in diagnosis due to the requirement for technical expertise. In contrast, abdominal fat pad fine needle aspiration (FPFNA) is a simple, safe and well-established procedure in systemic amyloidosis, but its diagnostic sensitivity in patients with suspected CA remains unclear. Methods and results We assessed the diagnostic sensitivity of FPFNA in 600 consecutive patients diagnosed with CA [216 AL amyloidosis, 113 hereditary transthyretin (ATTRm), and 271 wild-type transthyretin (ATTRwt) amyloidosis] at our Centre. Amyloid was detected on Congo red staining of FPFNAs in 181/216 (84%) patients with cardiac AL amyloidosis, including 100, 97, and 78% of those with a large, moderate, and small whole-body amyloid burden, respectively, as assessed by serum amyloid P (SAP) component scintigraphy (P < 0.001); the deposits were successfully typed as AL by immunohistochemistry in 102/216 (47%) cases. Amyloid was detected in FPFNAs of 51/113 (45%) patients with ATTRm CA, and only 42/271 (15%) cases with ATTRwt CA. Conclusions FPFNA has reasonable diagnostic sensitivity in cardiac AL amyloidosis, particularly in patients with a large whole-body amyloid burden. Although the diagnostic sensitivity of FPFNA is substantially lower in transthyretin CA, particularly ATTRwt, it may nevertheless sometimes obviate the need for endomyocardial biopsy. PMID:28605421
2013-01-01
Background Proper evaluation of new diagnostic tests is required to reduce overutilization and to limit potential negative health effects and costs related to testing. A decision analytic modelling approach may be worthwhile when a diagnostic randomized controlled trial is not feasible. We demonstrate this by assessing the cost-effectiveness of modified transesophageal echocardiography (TEE) compared with manual palpation for the detection of atherosclerosis in the ascending aorta. Methods Based on a previous diagnostic accuracy study, actual Dutch reimbursement data, and evidence from literature we developed a Markov decision analytic model. Cost-effectiveness of modified TEE was assessed for a life time horizon and a health care perspective. Prevalence rates of atherosclerosis were age-dependent and low as well as high rates were applied. Probabilistic sensitivity analysis was applied. Results The model synthesized all available evidence on the risk of stroke in cardiac surgery patients. The modified TEE strategy consistently resulted in more adapted surgical procedures and, hence, a lower risk of stroke and a slightly higher number of life-years. With 10% prevalence of atherosclerosis the incremental cost-effectiveness ratio was €4,651 and €481 per quality-adjusted life year in 55-year-old men and women, respectively. In all patients aged 65 years or older the modified TEE strategy was cost saving and resulted in additional health benefits. Conclusions Decision analytic modelling to assess the cost-effectiveness of a new diagnostic test based on characteristics, costs and effects of the test itself and of the subsequent treatment options is both feasible and valuable. Our case study on modified TEE suggests that it may reduce the risk of stroke in cardiac surgery patients older than 55 years at acceptable cost-effectiveness levels. PMID:23368927