Sohrabi, Mehdi; Parsi, Masoumeh; Sina, Sedigheh
2018-05-17
A diagnostic reference level is an advisory dose level set by a regulatory authority in a country as an efficient criterion for protection of patients from unwanted medical exposure. In computed tomography, the direct dose measurement and data collection methods are commonly applied for determination of diagnostic reference levels. Recently, a new quality-control-based dose survey method was proposed by the authors to simplify the diagnostic reference-level determination using a retrospective quality control database usually available at a regulatory authority in a country. In line with such a development, a prospective dual-purpose quality control dosimetry protocol is proposed for determination of diagnostic reference levels in a country, which can be simply applied by quality control service providers. This new proposed method was applied to five computed tomography scanners in Shiraz, Iran, and diagnostic reference levels for head, abdomen/pelvis, sinus, chest, and lumbar spine examinations were determined. The results were compared to those obtained by the data collection and quality-control-based dose survey methods, carried out in parallel in this study, and were found to agree well within approximately 6%. This is highly acceptable for quality-control-based methods according to International Atomic Energy Agency tolerance levels (±20%).
Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.
Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T
2017-12-01
The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.
SU-E-P-10: Establishment of Local Diagnostic Reference Levels of Routine Exam in Computed Tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, M; Wang, Y; Weng, H
Introduction National diagnostic reference levels (NDRLs) can be used as a reference dose of radiological examination can provide radiation dose as the basis of patient dose optimization. Local diagnostic reference levels (LDRLs) by periodically view and check doses, more efficiency to improve the way of examination. Therefore, the important first step is establishing a diagnostic reference level. Computed Tomography in Taiwan had been built up the radiation dose limit value,in addition, many studies report shows that CT scan contributed most of the radiation dose in different medical. Therefore, this study was mainly to let everyone understand DRL’s international status. Formore » computed tomography in our hospital to establish diagnostic reference levels. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). Each exam each different body part, we collect 10 patients at least. Carried out the routine examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. Results: The majority of patients (75%) were between 60–70 Kg of body weight. There are 25 examinations in this study. Table 1 shows the LDRL of each CT routine examination. Conclusions: Therefore, this study would like to let everyone know DRL’s international status, but also establishment of computed tomography of the local reference levels for our hospital, and providing radiation reference, as a basis for optimizing patient dose.« less
[Diagnostic reference levels in interventional radiology].
Vañó Carruana, E; Fernández Soto, J M; Sánchez Casanueva, R M; Ten Morón, J I
2013-12-01
This article discusses the diagnostic reference levels for radiation exposure proposed by the International Commission on Radiological Protection (ICRP) to facilitate the application of the optimization criteria in diagnostic imaging and interventional procedures. These levels are normally established as the third quartile of the dose distributions to patients in an ample sample of centers and are supposed to be representative of good practice regarding patient exposure. In determining these levels, it is important to evaluate image quality as well to ensure that it is sufficient for diagnostic purposes. When the values for the dose received by patients are systematically higher or much lower than the reference levels, an investigation should determine whether corrective measures need to be applied. The European and Spanish regulations require the use of these reference values in quality assurance programs. For interventional procedures, the dose area product (or kerma area product) values are usually used as reference values together with the time under fluoroscopy and the total number of images acquired. The most modern imaging devices allow the value of the accumulated dose at the entrance to the patient to be calculated to optimize the distribution of the dose on the skin. The ICRP recommends that the complexity of interventional procedures be taken into account when establishing reference levels. In the future, diagnostic imaging departments will have automatic systems to manage patient dosimetric data; these systems will enable continuous dosage auditing and alerts about individual procedures that might involve doses several times above the reference values. This article also discusses aspects that need to be clarified to take better advantage of the reference levels in interventional procedures. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Bas Mor, H; Altinsoy, N; Söyler, I
2018-05-08
The aim of this study was to evaluate the radiation doses to patient during chest (posterior anterior/and lateral) examinations. The study was performed in three public hospitals of İstanbul province with a total of 300 adult patients. Entrance surface dose (ESD) measurements were conducted on computed radiography, digital radiography and screen film system. ESD was estimated by using International Atomic Energy Agency (IAEA) model and Davies model which are the common indirect models. Results were compared with diagnostic reference levels from the European Commission, IAEA and National Radiological Protection Board. Although the results are compatible with the international diagnostic reference levels, they present variations between the hospitals. Dose variations for the same type of X-ray examination support the idea that further optimization is possible.
Sánchez-Muñoz, Laura; Morgado, Jose M; Álvarez-Twose, Ivan; Matito, Almudena; Garcia-Montero, Andrés C; Teodosio, Cristina; Jara-Acevedo, Maria; Mayado, Andrea; Mollejo, Manuela; Caldas, Carolina; González de Olano, David; Escribano, Luis; Orfao, Alberto
2016-01-01
The diagnosis of 'rare diseases', such as mastocytosis, remains a challenge. Despite this, the precise benefits of referral of mastocytosis patients to highly specialized reference centres are poorly defined and whether patients should be managed at non-specialized versus reference centres remains a matter of debate. To evaluate the quality and efficiency of diagnostic procedures performed at the reference centres for mastocytosis in Spain (REMA) versus other non-reference centres, we retrospectively analysed a series of 122 patients, for the overall degree of agreement obtained for the World Health Organization (WHO) diagnostic and classification criteria betwen the referring and REMA centres. Our results showed that not all WHO diagnostic criteria were frequently investigated at the referring centres. Among the five WHO diagnostic criteria, the highest degree of agreement was obtained for serum tryptase levels [median 90% (95% confidence interval 84-96%)]; in turn, the overall agreement was significantly lower for the major histopathological criterion [80% (72-89%)], and the other three minor criteria: cytomorphology [68% (56-80%)] immunophenotyping of BM mast cells [75% (62-87%)] and detection of the KIT mutation [34% (8-60%)]. Referral of patients with diagnostic suspicion of mastocytosis to a multidisciplinary reference centre improves diagnostic efficiency and quality. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Rasuli, Behrouz; Tabari Juybari, Raheleh; Forouzi, Meysam; Ghorbani, Mohammad
2017-09-01
Introduction: The main purpose of this study was to investigate patient dose in pelvic and abdomen x-ray examinations. This work also provided the LDRLs (local diagnostic reference levels) in Khuzestan region, southwest of Iran to help establish the NDRLs (national diagnostic reference levels). Methods: Patient doses were assessed from patient's anatomical data and exposure parameters based on the IAEA indirect dosimetry method. With regard to this method, exposure parameters such as tube output, kVp, mAs, FFD and patient anatomical data were used for calculating ESD (entrance skin dose) of patients. This study was conducted on 250 standard patients (50% men and 50% women) at eight high-patient-load imaging centers. Results: The results indicate that mean ESDs for the both pelvic and abdomen examinations were lower than the IAEA and EC reference levels, 2.3 and 3.7 mGy, respectively. Mean applied kVps were 67 and 70 and mean FFDs were 103 and 109, respectively. Tube loadings obtained in this study for pelvic examination were lower than all the corresponding values in the reviewed literature. Likewise, the average annual patient load across all hospitals were more than 37000 patients, i.e. more than 100 patients a day. Conclusions: The authors recommend that DRLs (diagnostic reference levels) obtained in this region, which are the first available data, can be used as local DRLs for pelvic and abdomen procedures. This work also provides that on-the-job training programs for staffs and close cross collaboration between physicists and physicians should be strongly considered.
Vassileva, J; Dimov, A; Slavchev, A; Karadjov, A
2005-01-01
Results from a Bulgarian patient dose survey in diagnostic radiology are presented. Reference levels for entrance surface dose (ESD) were 0.9 mGy for chest radiography (PA), 30 mGy for lumbar spine (Lat), 10 mGy for pelvis, 5 mGy for skull (AP), 3 mGy for skull (Lat) and 13 mGy for mammography. Quality control (QC) programmes were proposed for various areas of diagnostic radiology. Film processing QC warranted special attention. Proposed QC programmes included parameters to be tested, level of expertise needed and two action levels: remedial and suspension. Programmes were tested under clinical conditions to assess initial results and draw conclusions for further QC system development. On the basis of international experience, measurement protocols were developed for all parameters tested. QC equipment was provided as part of the PHARE project. A future problem for QC programme implementation may be the small number of medical physics experts in diagnostic radiology.
Anna, Hayton; Wallace, Anthony; Thomas, Peter
2017-03-01
The national diagnostic reference level service (NDRLS), was launched in 2011, however no paediatric data were submitted during the first calendar year of operation. As such, Australian national diagnostic reference levels (DRLs), for paediatric multi detector computed tomography (MDCT), were established using data obtained from a Royal Australian and New Zealand College of Radiologists (RANZCR), Quality Use of Diagnostic Imaging (QUDI), study. Paediatric data were submitted to the NDRLS in 2012 through 2015. An analysis has been made of the NDRLS paediatric data using the same method as was used to analyse the QUDI data to establish the Australian national paediatric DRLs for MDCT. An analysis of the paediatric NDRLS data has also been made using the method used to calculate the Australian national adult DRLs for MDCT. A comparison between the QUDI data and subsequent NDRLS data shows the NDRLS data to be lower on average for the Head and AbdoPelvis protocol and similar for the chest protocol. Using an average of NDRLS data submitted between 2012 and 2015 implications for updated paediatric DRLS are considered.
Sonawane, A U; Shirva, V K; Pradhan, A S
2010-02-01
Skin entrance doses (SEDs) were estimated by carrying out measurements of air kerma from 101 X-ray machines installed in 45 major and selected hospitals in the country by using a silicon detector-based dose Test-O-Meter. 1209 number of air kerma measurements of diagnostic projections for adults have been analysed for seven types of common diagnostic examinations, viz. chest (AP, PA, LAT), lumbar spine (AP, LAT), thoracic spine (AP, LAT), abdomen (AP), pelvis (AP), hip joints (AP) and skull (PA, LAT) for different film-screen combinations. The values of estimated diagnostic reference levels (DRLs) (third quartile values of SEDs) were compared with guidance levels/DRLs of doses published by the IAEA-BSS-Safety Series No. 115, 1996; HPA (NRPB) (2000 and 2005), UK; CRCPD/CDRH (USA), European Commission and other national values. The values of DRLs obtained in this study are comparable with the values published by the IAEA-BSS-115 (1996); HPA (NRPB) (2000 and 2005) UK; EC and CRCPD/CDRH, USA including values obtained in previous studies in India.
Validated age-specific reference values for CSF total protein levels in children.
Kahlmann, V; Roodbol, J; van Leeuwen, N; Ramakers, C R B; van Pelt, D; Neuteboom, R F; Catsman-Berrevoets, C E; de Wit, M C Y; Jacobs, B C
2017-07-01
To define age-specific reference values for cerebrospinal fluid (CSF) total protein levels for children and validate these values in children with Guillain-Barré syndrome (GBS), acute disseminated encephalomyelitis (ADEM) and multiple sclerosis (MS). Reference values for CSF total protein levels were determined in an extensive cohort of diagnostic samples from children (<18 year) evaluated at Erasmus Medical Center/Sophia Children's Hospital. These reference values were confirmed in children diagnosed with disorders unrelated to raised CSF total protein level and validated in children with GBS, ADEM and MS. The test results of 6145 diagnostic CSF samples from 3623 children were used to define reference values. The reference values based on the upper limit of the 95% CI (i.e. upper limit of normal) were for 6 months-2 years 0.25 g/L, 2-6 years 0.25 g/L, 6-12 years 0.28 g/L, 12-18 years 0.34 g/L. These reference values were confirmed in a subgroup of 378 children diagnosed with disorders that are not typically associated with increased CSF total protein. In addition, the CSF total protein levels in these children in the first 6 months after birth were highly variable (median 0.47 g/L, IQR 0.26-0.65). According to these new reference values, CSF total protein level was elevated in 85% of children with GBS, 66% with ADEM and 23% with MS. More accurate age-specific reference values for CSF total protein levels in children were determined. These new reference values are more sensitive than currently used values for diagnosing GBS and ADEM in children. Copyright © 2017 European Paediatric Neurology Society. Published by Elsevier Ltd. All rights reserved.
Mögling, Ramona; Zeller, Hervé; Revez, Joana; Koopmans, Marion; Reusken, Chantal
2017-01-01
With international travel, Zika virus (ZIKV) is introduced to Europe regularly. A country's ability to robustly detect ZIKV introduction and local transmission is important to minimise the risk for a ZIKV outbreak. Therefore, sufficient expertise and diagnostic capacity and capability are required in European laboratories. To assess the capacity, quality, operational specifics (guidelines and algorithms), technical and interpretation issues and other possible difficulties that were related to ZIKV diagnostics in European countries, a questionnaire was conducted among national reference laboratories in 30 countries in the European Union/European Economic Area (EU/EEA) in May 2016. While the coverage and capacity of ZIKV diagnostics in the EU/EEA national reference laboratories were found to be adequate, the assessment of the quality and needs indicated several crucial points of improvement that will need support at national and EU/EEA level to improve ZIKV preparedness, response and EU/EEA ZIKV surveillance activities. PMID:28920574
Naicker, Serisha D; Govender, Nevashan; Patel, Jaymati; Zietsman, Inge L; Wadula, Jeannette; Coovadia, Yacoob; Kularatne, Ranmini; Seetharam, Sharona; Govender, Nelesh P
2016-11-01
From February 2009 through August 2010, we compared species-level identification of bloodstream Candida isolates and susceptibility to fluconazole, voriconazole, and caspofungin between diagnostic and reference South African laboratories during national surveillance for candidemia. Diagnostic laboratories identified isolates to genus/species level and performed antifungal susceptibility testing, as indicated. At a reference laboratory, viable Candida isolates were identified to species-level using automated systems, biochemical tests, or DNA sequencing; broth dilution susceptibility testing was performed. Categorical agreement (CA) was calculated for susceptibility results of isolates with concordant species identification. Overall, 2172 incident cases were detected, 773 (36%) by surveillance audit. The Vitek 2 YST system (bioMérieux Inc, Marcy l'Etoile, France) was used for identification (360/863, 42%) and susceptibility testing (198/473, 42%) of a large proportion of isolates. For the five most common species (n = 1181), species-level identification was identical in the majority of cases (Candida albicans: 98% (507/517); Candida parapsilosis: 92% (450/488); Candida glabrata: 89% (89/100); Candida tropicalis: 91% (49/54), and Candida krusei: 86% (19/22)). However, diagnostic laboratories were significantly less likely to correctly identify Candida species other than C. albicans versus C. albicans (607/664, 91% vs. 507/517, 98%; P < .001). Susceptibility data were compared for isolates belonging to the five most common species and fluconazole, voriconazole, and caspofungin in 860, 580, and 99 cases, respectively. Diagnostic laboratories significantly under-reported fluconazole resistance in C. parapsilosis (225/393, 57% vs. 239/393, 61%; P < .001) but over-reported fluconazole non-susceptibility in C. albicans (36/362, 10% vs. 3/362, 0.8%; P < .001). Diagnostic laboratories were less likely to correctly identify Candida species other than C. albicans, under-reported fluconazole resistance for C. parapsilosis and over-reported fluconazole resistance for C. albicans. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Bibbo, Giovanni; Brown, Scott; Linke, Rebecca
2016-08-01
Diagnostic Reference Levels (DRL) of procedures involving ionizing radiation are important tools to optimizing radiation doses delivered to patients and in identifying cases where the levels of doses are unusually high. This is particularly important for paediatric patients undergoing computed tomography (CT) examinations as these examinations are associated with relatively high-dose. Paediatric CT studies, performed at our institution from January 2010 to March 2014, have been retrospectively analysed to determine the 75th and 95th percentiles of both the volume computed tomography dose index (CTDIvol ) and dose-length product (DLP) for the most commonly performed studies to: establish local diagnostic reference levels for paediatric computed tomography examinations performed at our institution, benchmark our DRL with national and international published paediatric values, and determine the compliance of CT radiographer with established protocols. The derived local 75th percentile DRL have been found to be acceptable when compared with those published by the Australian National Radiation Dose Register and two national children's hospitals, and at the international level with the National Reference Doses for the UK. The 95th percentiles of CTDIvol for the various CT examinations have been found to be acceptable values for the CT scanner Dose-Check Notification. Benchmarking CT radiographers shows that they follow the set protocols for the various examinations without significant variations in the machine setting factors. The derivation of DRL has given us the tool to evaluate and improve the performance of our CT service by improved compliance and a reduction in radiation dose to our paediatric patients. We have also been able to benchmark our performance with similar national and international institutions. © 2016 The Royal Australian and New Zealand College of Radiologists.
Diagnostic Challenges of Central Nervous System Tuberculosis
Loeffler, Ann M.; Honarmand, Somayeh; Flood, Jennifer M.; Baxter, Roger; Jacobson, Susan; Alexander, Rick; Glaser, Carol A.
2008-01-01
Central nervous system tuberculosis (TB) was identified in 20 cases of unexplained encephalitis referred to the California Encephalitis Project. Atypical features (encephalitic symptoms, rapid onset, age) and diagnostic challenges (insensitive cerebrospinal fluid [CSF] TB PCR result, elevated CSF glucose levels in patients with diabetes, negative result for tuberculin skin test) complicated diagnosis. PMID:18760024
[Pediatric reference intervals : retrospective study on thyroid hormone levels].
Ladang, A; Vranken, L; Luyckx, F; Lebrethon, M-C; Cavalier, E
2017-01-01
Defining reference range is an essential tool for diagnostic. Age and sexe influences on thyroid hormone levels have been already discussed. In this study, we are defining a new pediatric reference range for TSH, FT3 and FT4 for Cobas C6000 analyzer. To do so, we have taken in account 0 to 18 year old outclinic patients. During the first year of life, thyroid hormone levels change dramatically before getting stabilized around 3 years old. We also compared our results to those obtained in a Canadian large-scale prospective study (the CALIPER initiative).
Unemo, Magnus; Golparian, Daniel; Sánchez-Busó, Leonor; Grad, Yonatan; Jacobsson, Susanne; Ohnishi, Makoto; Lahra, Monica M; Limnios, Athena; Sikora, Aleksandra E; Wi, Teodora; Harris, Simon R
2016-11-01
Gonorrhoea and MDR Neisseria gonorrhoeae remain public health concerns globally. Enhanced, quality-assured, gonococcal antimicrobial resistance (AMR) surveillance is essential worldwide. The WHO global Gonococcal Antimicrobial Surveillance Programme (GASP) was relaunched in 2009. We describe the phenotypic, genetic and reference genome characteristics of the 2016 WHO gonococcal reference strains intended for quality assurance in the WHO global GASP, other GASPs, diagnostics and research worldwide. The 2016 WHO reference strains (n = 14) constitute the eight 2008 WHO reference strains and six novel strains. The novel strains represent low-level to high-level cephalosporin resistance, high-level azithromycin resistance and a porA mutant. All strains were comprehensively characterized for antibiogram (n = 23), serovar, prolyliminopeptidase, plasmid types, molecular AMR determinants, N. gonorrhoeae multiantigen sequence typing STs and MLST STs. Complete reference genomes were produced using single-molecule PacBio sequencing. The reference strains represented all available phenotypes, susceptible and resistant, to antimicrobials previously and currently used or considered for future use in gonorrhoea treatment. All corresponding resistance genotypes and molecular epidemiological types were described. Fully characterized, annotated and finished references genomes (n = 14) were presented. The 2016 WHO gonococcal reference strains are intended for internal and external quality assurance and quality control in laboratory investigations, particularly in the WHO global GASP and other GASPs, but also in phenotypic (e.g. culture, species determination) and molecular diagnostics, molecular AMR detection, molecular epidemiology and as fully characterized, annotated and finished reference genomes in WGS analysis, transcriptomics, proteomics and other molecular technologies and data analysis. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
ERIC Educational Resources Information Center
International Labour Office, Islamabad (Pakistan). Asian and Pacific Skill Development Programme.
This screening and diagnostic procedure is intended to identify Level 1 adults with specific learning problems. The adults not meeting criteria on the assessments for visual and auditory functions should be referred to proper medical services for full evaluations. A prescriptive teaching program should be specifically designed to meet needs of…
Almén, Anja; Båth, Magnus
2016-06-01
The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith
2010-02-01
To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.
Laslett, Mark; McDonald, Barry; Tropp, Hans; Aprill, Charles N; Öberg, Birgitta
2005-01-01
Background The tissue origin of low back pain (LBP) or referred lower extremity symptoms (LES) may be identified in about 70% of cases using advanced imaging, discography and facet or sacroiliac joint blocks. These techniques are invasive and availability varies. A clinical examination is non-invasive and widely available but its validity is questioned. Diagnostic studies usually examine single tests in relation to single reference standards, yet in clinical practice, clinicians use multiple tests and select from a range of possible diagnoses. There is a need for studies that evaluate the diagnostic performance of clinical diagnoses against available reference standards. Methods We compared blinded clinical diagnoses with diagnoses based on available reference standards for known causes of LBP or LES such as discography, facet, sacroiliac or hip joint blocks, epidurals injections, advanced imaging studies or any combination of these tests. A prospective, blinded validity design was employed. Physiotherapists examined consecutive patients with chronic lumbopelvic pain and/or referred LES scheduled to receive the reference standard examinations. When diagnoses were in complete agreement regardless of complexity, "exact" agreement was recorded. When the clinical diagnosis was included within the reference standard diagnoses, "clinical agreement" was recorded. The proportional chance criterion (PCC) statistic was used to estimate agreement on multiple diagnostic possibilities because it accounts for the prevalence of individual categories in the sample. The kappa statistic was used to estimate agreement on six pathoanatomic diagnoses. Results In a sample of chronic LBP patients (n = 216) with high levels of disability and distress, 67% received a patho-anatomic diagnosis based on available reference standards, and 10% had more than one tissue origin of pain identified. For 27 diagnostic categories and combinations, chance clinical agreement (PCC) was estimated at 13%. "Exact" agreement between clinical and reference standard diagnoses was 32% and "clinical agreement" 51%. For six pathoanatomic categories (disc, facet joint, sacroiliac joint, hip joint, nerve root and spinal stenosis), PCC was 33% with actual agreement 56%. There was no overlap of 95% confidence intervals on any comparison. Diagnostic agreement on the six most common patho-anatomic categories produced a kappa of 0.31. Conclusion Clinical diagnoses agree with reference standards diagnoses more often than chance. Using available reference standards, most patients can have a tissue source of pain identified. PMID:15943873
Chang, Ming-Chu; Liang, Po-Chin; Jan, I-Shiow; Yang, Ching-Yao; Tien, Yu-Wen; Wei, Shu-Chen; Wong, Jau-Min; Chang, Yu-Ting
2014-08-18
The International Consensus Diagnostic Criteria (ICDC) designed to diagnosis autoimmune pancreatitis (AIP) has been proposed recently. The diagnostic performance of ICDC has not been previously evaluated in diffuse-type and focal-type AIP, respectively, in comparison with the revised HISORt and Asian criteria in Taiwan. Prospective, consecutive patient cohort. Largest tertiary referred centre hospital managing pancreatic disease in Taiwan. 188 patients with AIP and 130 with tissue proofed pancreatic adenocarcinoma were consecutively recruited. The ICDC, as well as revised HISORt and Asian criteria, was applied for each participant. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in diffuse-type and focal-type AIP. Sensitivity, specificity and accuracy. Each diagnostic criterion of ICDC was validated with special reference to levels 1 and 2 in AIP and focal-type AIP. The sensitivity, specificity and accuracy of ICDC for all AIP were the best: 89.4%, 100% and 93.7%, respectively, in these three criteria. The sensitivity, specificity and accuracy of ICDC for focal-type AIP (84.9%, 100% and 93.8%) were also the best among these three criteria. The area under the curve of receiver-operator characteristic of ICDC was 0.95 (95% CI 0.92 to 0.97) in all AIP and 0.93 (95% CI 0.88 to 0.97) in focal-type AIP. The sensitivity, specificity and accuracy of ICDC are higher than the revised HISORt and Asian criteria. The sensitivity, specificity and accuracy of each criterion are higher in diffuse-type AIP compared with focal-type AIP. Under the same specificity, the sensitivity and accuracy of ICDC are higher than other diagnostic criteria in focal-type AIP. ICDC has better diagnostic performance compared with previously proposed diagnostic criteria in diffuse-type and focal-type AIP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Jibiri, Nnamdi N.
2016-01-01
In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic purposes. However, most examinations carried out do not have records of doses received by the patients, and the employed exposure parameters used are not documented; therefore, adequate radiation dose management is hindered. The aim of the present study was to estimate the dose‐area product (DAP) of patients examined in Nigeria, and to propose regional reference dose levels for nine common examinations (chest PA, abdomen AP, pelvis AP, lumbar AP, skull AP, leg AP, knee AP, hand AP, and thigh AP) undertaken in Nigeria. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDS were converted into DAP using the beam area of patients in 12 purposely selected hospitals. Results of the study show that the maximum/minimum ratio ranged from 3 for thigh AP to 57 in abdomen AP. The range of determined mean and 75th percentile DAPs were 0.18–17.16, and 0.25–28.59 Gy cm2, respectively. Data available for comparison show that 75th percentile DAPs in this study (in chest PA, abdomen AP, pelvis AP, lumbar AP) are higher than NRPB‐HPE reference values. The DAP in this study is higher by factor of 31.4 (chest PA), 9.9 (abdomen AP), 2.2 (pelvis AP), and 2.1 (lumbar AP) than NRPB‐HPE values. The relative higher dose found in this study shows nonoptimization of practice in Nigeria. It is expected that regular dose auditing and dose optimization implementation in Nigeria would lead to lower DAP value, especially in abdomen AP. The 75th percentile DAP distribution reported in this study could be taken as regional diagnostic reference level in the Southwestern Nigeria; however, a more extensive nationwide dose survey is required to establish national reference dose. PACS number(s): 87.53.Bn, 87.59.B PMID:27929511
Jibiri, Nnamdi N; Olowookere, Christopher J
2016-11-08
In Nigeria, a large number of radiographic examinations are conducted yearly for various diagnostic purposes. However, most examinations carried out do not have records of doses received by the patients, and the employed exposure parameters used are not documented; therefore, adequate radiation dose management is hin-dered. The aim of the present study was to estimate the dose-area product (DAP) of patients examined in Nigeria, and to propose regional reference dose levels for nine common examinations (chest PA, abdomen AP, pelvis AP, lumbar AP, skull AP, leg AP, knee AP, hand AP, and thigh AP) undertaken in Nigeria. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDS were converted into DAP using the beam area of patients in 12 purposely selected hospitals. Results of the study show that the maximum/ minimum ratio ranged from 3 for thigh AP to 57 in abdomen AP. The range of determined mean and 75th percentile DAPs were 0.18-17.16, and 0.25-28.59 Gy cm2, respectively. Data available for comparison show that 75th percentile DAPs in this study (in chest PA, abdomen AP, pelvis AP, lumbar AP) are higher than NRPB-HPE reference values. The DAP in this study is higher by factor of 31.4 (chest PA), 9.9 (abdomen AP), 2.2 (pelvis AP), and 2.1 (lumbar AP) than NRPB-HPE values. The relative higher dose found in this study shows nonoptimization of practice in Nigeria. It is expected that regular dose auditing and dose optimization implementation in Nigeria would lead to lower DAP value, especially in abdomen AP. The 75th percentile DAP distribution reported in this study could be taken as regional diagnostic reference level in the Southwestern Nigeria; however, a more extensive nationwide dose survey is required to establish national reference dose. © 2016 The Authors.
Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L
2008-11-01
Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.
Sohrabi, Mehdi; Parsi, Masoumeh; Mianji, Fereidoun
2018-05-01
National diagnostic reference levels (NDRLs) of Iran were determined for the four most common CT examinations including head, sinus, chest and abdomen/pelvis. A new 'quality control (QC)-based dose survey method', as developed by us, was applied to 157 CT scanners in Iran (2014-15) with different slice classes, models and geographic spread across the country. The NDRLs for head, sinus, chest and abdomen/pelvis examinations are 58, 29, 12 and 14 mGy for CTDIVol and 750, 300, 300 and 650 mGy.cm for DLP, respectively. The 'QC-based dose survey method' was further proven that it is a simple, accurate and practical method for a time and cost-effective NDRLs determination. One effective approach for optimization of the CT examination protocols at the national level is the provision of an adequate standardized training of the radiologists, technicians and medical physicists on the patient radiation protection principles and implementation of the DRL concept in clinical practices.
Trends in radiation exposure from clinical nuclear medicine procedures in Shanghai, China.
Yi, Yanling; Zheng, Junzheng; Zhuo, Weihai; Gao, Linfeng
2012-03-01
This study was designed to assess the trends in the frequencies of nuclear medicine procedures in Shanghai, China, and to determine their contributions to the per capita effective dose to the Shanghai population. The mean activities of radionuclides administered by nuclear medicine departments were compared with the Chinese national guidelines on diagnostic reference levels. On the basis of the three surveys carried out by Shanghai Municipal Center for Disease Control and Prevention in 1996, 1998, and 2008, the typically administered radiopharmaceuticals, levels of activity, the number of procedures, and population were systematically analyzed to assess the frequencies of nuclear medicine procedures and the per capita effective dose. The frequencies were approximately 2.77, 3.46, and 6.63 per 1000 people in 1996, 1998, and 2008, respectively. The annual per capita doses from diagnostic nuclear medicine were estimated to be 0.016, 0.022, and 0.032 mSv in 1996, 1998, and 2008, respectively. The annual frequency of therapeutic nuclear medicine procedures increased from 0.131 to 0.430 per 1000 people in the intervening 12 years. In the 12 years before 2008, diagnostic and therapeutic procedures in nuclear medicine in Shanghai increased continuously, and the annual per capita dose doubled. Increases in PET imaging and bone scans were the major contributors to the increasing frequency and magnitude of radiation exposure to the population. The activities administered for most diagnostic procedures were generally consistent with the designated reference levels.
Patient dosimetry audit for establishing local diagnostic reference levels for nuclear medicine CT.
Gardner, Matthew; Katsidzira, Ngonidzashe M; Ross, Erin; Larkin, Elizabeth A
2017-03-01
To establish a system for patient dosimetry audit and setting of local diagnostic reference levels (LDRLs) for nuclear medicine (NM) CT. Computed radiological information system (CRIS) data were matched with NM paper records, which provided the body region and dose mode for NMCT carried out at a large UK hospital. It was necessary to divide data in terms of the NM examination type, body region and dose mode. The mean and standard deviation dose-length products (DLPs) for common NMCT examinations were then calculated and compared with the proposed National Diagnostic Reference Levels (NDRLs). Only procedures which have 10 or more patients will be used to suggest LDRLs. For most examinations, the mean DLPs do not exceed the proposed NDRLs. The bone single-photon emission CT/CT lumbar spine data clearly show the need to divide data according to the purpose of the scan (dose mode), with mean (±standard error) DLPs ranging from 51 ± 5 mGy cm (low dose) to 1086 ± 124 mGy cm (metal dose). A system for NMCT patient dose audit has been developed, but there are non-trivial challenges which make the process labour intensive. These include limited information provided by CRIS downloads, dependence on paper records and limited number of examinations available owing to the need to subdivide data. Advances in knowledge: This article demonstrates that a system can be developed for NMCT patient dose audit, but also highlights the challenges associated with such audit, which may not be encountered with more routine audit of radiology CT.
Weye, Nanna; Fonager, Kirsten; Lützen, Tina; Rytter, Dorte
2018-05-25
In Denmark, the human papillomavirus (HPV) vaccines have been suspected of adverse events since 2014. However, as no causal associations between the HPV vaccines and numerous diseases have been demonstrated, factors prior to vaccination may influence the risk of suspecting the HPV vaccines of causing symptoms. We studied the associations between individual and parental socioeconomic characteristics and the risk of referral to a diagnostic centre in a female population aged 11-29 years with a first HPV vaccination in January 2008 to June 2015. Individual and parental data from national registries were linked using the unique personal identification number. Logistic regression analyses were used to estimate crude and adjusted odds ratio's according to each individual and parental socioeconomic factor with two-sided 95% 95% CI. The cohort consisted of 453 216 individuals of which 1316 (0.29%) were referred to a diagnostic centre in 2015. Having a mother outside the workforce or an unemployed mother was associated with an increased risk of referral, while girls and women who had fathers with a higher educational level were less likely to be referred. In addition, women aged 20-29 years who were unemployed or outside the workforce prior to vaccination had increased odds of being referred to a diagnostic centre. We found social inequality in the referral to a diagnostic centre following HPV vaccination. This might be explained by an increased morbidity in girls and women of lower socioeconomic status.
Nasal potential difference measurements in diagnosis of cystic fibrosis: an international survey.
Naehrlich, Lutz; Ballmann, Manfred; Davies, Jane; Derichs, Nico; Gonska, Tanja; Hjelte, Lena; van Konigsbruggen-Rietschel, Silke; Leal, Teresinha; Melotti, Paola; Middleton, Peter; Tümmler, Burkhard; Vermeulen, Francois; Wilschanski, Michael
2014-01-01
The role of nasal potential difference (NPD) measurement as a diagnostic test for cystic fibrosis (CF) is a subject of global controversy because of the lack of validation studies, clear reference values, and standardized protocols for diagnostic NPD. To determine diagnostic NPD frequency, protocols, interpretation, and rater agreement, we surveyed the 18 NPD centres of the European Cystic Fibrosis Society Diagnostic Network Working Group. Fifteen centres reported performing 373 diagnostic NPDs in 2012. Most use the CFF-TDN-SOP (67%) and the chloride-free + isoproterenol response of the side with the largest response (47%) as diagnostic criteria and use centre-specific reference ranges. Rater agreement for five NPD tracings - in general - was good, but poor in tracings with different responses between the two nostrils. NPD is frequently used as a diagnostic and research tool for CF. Performance is highly standardized, centre-specific reference ranges are established, and rater agreement - in general - is good. Centre-independent diagnostic criteria and reference ranges must be defined by multicentre validation studies to improve standardized interpretation for diagnostic use. © 2013.
To what do psychiatric diagnoses refer? A two-dimensional semantic analysis of diagnostic terms
Maung, Hane Htut
2016-01-01
In somatic medicine, diagnostic terms often refer to the disease processes that are the causes of patients' symptoms. The language used in some clinical textbooks and health information resources suggests that this is also sometimes assumed to be the case with diagnoses in psychiatry. However, this seems to be in tension with the ways in which psychiatric diagnoses are defined in diagnostic manuals, according to which they refer solely to clusters of symptoms. This paper explores how theories of reference in the philosophy of language can help to resolve this tension. After the evaluation of descriptive and causal theories of reference, I put forward a conceptual framework based on two-dimensional semantics that allows the causal analysis of diagnostic terms in psychiatry, while taking seriously their descriptive definitions in diagnostic manuals. While the framework is presented as a solution to a problem regarding the semantics of psychiatric diagnoses, it can also accommodate the analysis of diagnostic terms in other medical disciplines. PMID:26580354
Vehicle Integrated Prognostic Reasoner (VIPR) Metric Report
NASA Technical Reports Server (NTRS)
Cornhill, Dennis; Bharadwaj, Raj; Mylaraswamy, Dinkar
2013-01-01
This document outlines a set of metrics for evaluating the diagnostic and prognostic schemes developed for the Vehicle Integrated Prognostic Reasoner (VIPR), a system-level reasoner that encompasses the multiple levels of large, complex systems such as those for aircraft and spacecraft. VIPR health managers are organized hierarchically and operate together to derive diagnostic and prognostic inferences from symptoms and conditions reported by a set of diagnostic and prognostic monitors. For layered reasoners such as VIPR, the overall performance cannot be evaluated by metrics solely directed toward timely detection and accuracy of estimation of the faults in individual components. Among other factors, overall vehicle reasoner performance is governed by the effectiveness of the communication schemes between monitors and reasoners in the architecture, and the ability to propagate and fuse relevant information to make accurate, consistent, and timely predictions at different levels of the reasoner hierarchy. We outline an extended set of diagnostic and prognostics metrics that can be broadly categorized as evaluation measures for diagnostic coverage, prognostic coverage, accuracy of inferences, latency in making inferences, computational cost, and sensitivity to different fault and degradation conditions. We report metrics from Monte Carlo experiments using two variations of an aircraft reference model that supported both flat and hierarchical reasoning.
Salem, L C; Vogel, A; Ebstrup, J; Linneberg, A; Waldemar, G
2015-12-01
Our objective was to examine the quantity and profile of subjective cognitive complaints in young patients as compared with elderly patients referred to a memory clinic. Patients were consecutively recruited from the Copenhagen University Hospital Memory Clinic at Rigshospitalet. In total, 307 patients and 149 age-matched healthy controls were included. Patients were classified in 4 diagnostic groups: dementia, mild cognitive impairment, affective disorders and no cognitive impairment. Subjective memory was assessed with subjective memory complaints (SMC) scale. Global cognitive functions were assessed with the Mini-mental state examination (MMSE) and Addenbrooke's cognitive examination (ACE), and symptoms of depression were rated with Major Depression Inventory (MDI). All interviews and the diagnostic conclusion were blinded to the SMC score. We found that young patients with dementia have a significantly higher level and a different profile of subjective cognitive complaints as compared with elderly patients with dementia. Furthermore, young patients, diagnosed with an affective disorder, had the highest level of subjective cognitive complaints of all patients in a memory clinic. The age of the patients and MDI score (but not MMSE or ACE) had significant impact on the level of subjective cognitive complaints. We have established that young patients with dementia have a different profile of subjective cognitive complaints than elderly patients, and further studies are needed to clarify possible relation to specific subtypes of dementia. Altogether, a systematic interview on subjective cognitive complaints may contribute to the diagnostic evaluation of patients referred to a memory clinic. Copyright © 2015 John Wiley & Sons, Ltd.
Implementation of Size-Dependent Local Diagnostic Reference Levels for CT Angiography.
Boere, Hub; Eijsvoogel, Nienke G; Sailer, Anna M; Wildberger, Joachim E; de Haan, Michiel W; Das, Marco; Jeukens, Cecile R L P N
2018-05-01
Diagnostic reference levels (DRLs) are established for standard-sized patients; however, patient dose in CT depends on patient size. The purpose of this study was to introduce a method for setting size-dependent local diagnostic reference levels (LDRLs) and to evaluate these LDRLs in comparison with size-independent LDRLs and with respect to image quality. One hundred eighty-four aortic CT angiography (CTA) examinations performed on either a second-generation or third-generation dual-source CT scanner were included; we refer to the second-generation dual-source CT scanner as "CT1" and the third-generation dual-source CT scanner as "CT2." The volume CT dose index (CTDI vol ) and patient diameter (i.e., the water-equivalent diameter) were retrieved by dose-monitoring software. Size-dependent DRLs based on a linear regression of the CTDI vol versus patient size were set by scanner type. Size-independent DRLs were set by the 5th and 95th percentiles of the CTDI vol values. Objective image quality was assessed using the signal-to-noise ratio (SNR), and subjective image quality was assessed using a 4-point Likert scale. The CTDI vol depended on patient size and scanner type (R 2 = 0.72 and 0.78, respectively; slope = 0.05 and 0.02 mGy/mm; p < 0.001). Of the outliers identified by size-independent DRLs, 30% (CT1) and 67% (CT2) were adequately dosed when considering patient size. Alternatively, 30% (CT1) and 70% (CT2) of the outliers found with size-dependent DRLs were not identified using size-independent DRLs. A negative correlation was found between SNR and CTDI vol (R 2 = 0.36 for CT1 and 0.45 for CT2). However, all outliers had a subjective image quality score of sufficient or better. We introduce a method for setting size-dependent LDRLs in CTA. Size-dependent LDRLs are relevant for assessing the appropriateness of the radiation dose for an individual patient on a specific CT scanner.
Analysis of serum angiotensin-converting enzyme.
Muller, B R
2002-09-01
Serum angiotensin-converting enzyme (SACE) levels are influenced by genetic polymorphism. Interpretation of serum levels with the appropriate genotypic reference range improves the diagnostic sensitivity of the assay for sarcoidosis. SACE assays are performed by a large number of routine clinical laboratories. However, there is no external quality assessment (EQA) for SACE other than an informal regional scheme. This showed analytical performance of SACE assays to be poor, with a diversity of reference ranges, leading to widely disparate clinical classification of EQA samples. Genetic polymorphism combined with poor analytical performance suggest that perhaps SACE assays should revert to being the province of specialized laboratories.
Oxygen effects on glucose measurements with a reference analyzer and three handheld meters.
Tang, Z; Louie, R F; Payes, M; Chang, K C; Kost, G J
2000-01-01
Oxygen may affect glucose meter and reference analyzer measurements. We evaluated the effects of changes in blood oxygen tension (Po2) on Accu-Chek Comfort Curve (Roche Diagnostics, Indianapolis, IN), Precision G, (Abbott Laboratories, Bedford, MA) and One Touch II (Lifescan, Milpitas, CA) glucose meter measurements, and on Yellow Springs Instruments (YSI) (Yellow Springs, OH) reference analyzer measurements. Venous blood drawn from healthy volunteers was adjusted to three glucose levels of 80, 200, and 400 mg/dL, each tonometered with six different Po2 levels (40, 80, 160, 240, 320, and 400 torr). To quantitate oxygen effects on reference analyzer measurements, glucose differences between test sample (Po2 changed) and control (Po2 80 torr) were calculated (YSItest-YSIcontrol). The threshold for determination of oxygen effects was +/-2 SD, where 2 SD was fro
Li, S; Tang, X; Peng, L; Luo, Y; Dong, R; Liu, J
2015-05-01
To review the literature on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) for the evaluation of myocardial ischaemia in patients with suspected or known coronary artery disease, with invasive fractional flow reserve (FFR) as the reference standard. A PubMed, EMBASE, and Cochrane cross-search was performed. The pooled diagnostic accuracy of FFRCT, with FFR as the reference standard, was primarily analysed, and then compared with that of CT angiography (CTA). The thresholds to diagnose ischaemia were FFR ≤0.80 or CTA ≥50% stenosis. Data extraction, synthesis, and statistical analysis were performed by standard meta-analysis methods. Three multicentre studies (NXT Trial, DISCOVER-FLOW study and DeFACTO study) were included, examining 609 patients and 1050 vessels. The pooled sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (LR+), negative likelihood ratio (LR-), and diagnostic odds ratio (DOR) for FFRCT were 89% (85-93%), 71% (65-75%), 70% (65-75%), 90% (85-93%), 3.31 (1.79-6.14), 0.16 (0.11-0.23), and 21.21 (9.15-49.15) at the patient-level, and 83% (78-63%), 78% (75-81%), 61% (56-65%), 92% (89-90%), 4.02 (1.84-8.80), 0.22 (0.13-0.35), and 19.15 (5.73-63.93) at the vessel-level. At per-patient analysis, FFRCT has similar sensitivity but improved specificity, PPV, NPV, LR+, LR-, and DOR versus those of CTA. At per-vessel analysis, FFRCT had a slightly lower sensitivity, similar NPV, but improved specificity, PPV, LR+, LR-, and DOR compared with those of CTA. The area under the summary receiver operating characteristic curves for FFRCT was 0.8909 at patient-level and 0.8865 at vessel-level, versus 0.7402 for CTA at patient-level. FFRCT, which was associated with improved diagnostic accuracy versus CTA, is a viable alternative to FFR for detecting coronary ischaemic lesions. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Ghetti, C; Ortenzia, O; Palleri, F; Sireus, M
2017-06-01
Dose optimization in radiological examinations is a mandatory issue: in this study local Diagnostic Reference Levels (lDRLs) for Clinical Mammography (MG), Computed Tomography (CT) and Interventional Cardiac Procedures (ICP) performed in our Radiology Department were established. Using a dose tracking software, we have collected Average Glandular Dose (AGD) for two clinical mammographic units; CTDIvol, Size-Specific Dose Estimate (SSDE), Dose Length Product (DLP) and total DLP (DLPtot) for five CT scanners; Fluoro Time, Fluoro Dose Area Product (DAP) and total DAP (DAPtot) for two angiographic systems. Data have been compared with Italian Regulation and with the recent literature. The 75th percentiles of the different dosimetric indices have been calculated. Automated methods of radiation dose data collection allow a fast and detailed analysis of a great amount of data and an easy determination of lDRLs for different radiological procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
de Jesus, Fillipe M; Magalhães, Luis A G; Kodlulovich, Simone
2016-11-01
A pilot study of dose indicators in paediatric computed tomography (CT) was conducted to prove the need to establish diagnostic reference levels (DRLs) for the county of Rio de Janeiro. The dose descriptors were estimated from the beam dosimetry by applying the protocols used in each examination. The total patient sample included 279 children. Regarding the comparison of the dose-length product values among the hospitals, the high-resolution chest CT scans were distinguished among the three types of examinations, due to the discrepancies of 1148 % (1-5 y age group) and 2248 % (5-10 y age group) presented in Hospital A's dose-length product values relative to Hospital D's dose-length product values. The results showed that without DRL, the dose variation can be significant between hospitals in the same county for the same age group in the same examination. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Willegaignon, José; Braga, Luis F E F; Sapienza, Marcelo T; Coura-Filho, George B; Cardona, Marissa A R; Alves, Carlos E R; Gutterres, Ricardo F; Buchpiguel, Carlos A
2016-05-01
This study aimed to establish a concise method for determining a diagnostic reference level (DRL) for adult and pediatric nuclear medicine patients on the basis of diagnostic procedures and administered radioisotope as a means of controlling medical exposure. A screening was carried out in all Brazilian Nuclear Medicine Service (NMS) establishments to support this study by collecting the average activities administered during adult diagnostic procedures and the rules applied to adjust these according to the patient's age and body mass. Percentile 75 was used in all the activities administered as a means of establishing DRL for adult patients, with additional correction factors for pediatric patients. Radiation doses from nuclear medicine procedures on the basis of average administered activity were calculated for all diagnostic exams. A total of 107 NMSs in Brazil agreed to participate in the project. From the 64 nuclear medicine procedures studied, bone, kidney, and parathyroid scans were found to be used in more than 85% of all the NMSs analyzed. There was a large disparity among the activities administered, when applying the same procedures, this reaching, in some cases, more than 20 times between the lowest and the highest. Diagnostic exams based on Ga, Tl, and I radioisotopes proved to be the major exams administering radiation doses to patients. On introducing the DRL concept into clinical routine, the minimum reduction in radiation doses received by patients was about 15%, the maximum was 95%, and the average was 50% compared with the previously reported administered activities. Variability in the available diagnostic procedures as well as in the amount of activities administered within the same procedure was appreciable not only in Brazil, but worldwide. Global efforts are needed to establish a concise DRL that can be applied in adult and pediatric nuclear medicine procedures as the application of DRL in clinical routine has been proven to be an important tool for controlling and reducing radiation doses received by patients in medical exposure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bjarnason, Thorarin
Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used inmore » this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crowhurst, James A, E-mail: jimcrowhurst@hotmail.com; School of Medicine, University of Queensland, St. Lucia, Brisbane, Queensland; Whitby, Mark
Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P{sub KA}), skin surface entrance dose (K{sub AR}), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentilemore » of the P{sub KA.} 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median K{sub AR} = 581 mGy (374–876). Median P{sub KA} = 3908 uGym{sup 2} (2489–5865) DRL = 5865 uGym{sup 2}. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median K{sub AR} = 1501 mGy (928–2224). Median P{sub KA} = 8736 uGym{sup 2} (5449–12,900) DRL = 12,900 uGym{sup 2}. This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.« less
Diagnostic Concordance Among Pathologists Interpreting Breast Biopsy Specimens
Elmore, Joann G.; Longton, Gary M.; Carney, Patricia A.; Geller, Berta M.; Onega, Tracy; Tosteson, Anna N. A.; Nelson, Heidi D.; Pepe, Margaret S.; Allison, Kimberly H.; Schnitt, Stuart J.; O’Malley, Frances P.; Weaver, Donald L.
2015-01-01
IMPORTANCE A breast pathology diagnosis provides the basis for clinical treatment and management decisions; however, its accuracy is inadequately understood. OBJECTIVES To quantify the magnitude of diagnostic disagreement among pathologists compared with a consensus panel reference diagnosis and to evaluate associated patient and pathologist characteristics. DESIGN, SETTING, AND PARTICIPANTS Study of pathologists who interpret breast biopsies in clinical practices in 8 US states. EXPOSURES Participants independently interpreted slides between November 2011 and May 2014 from test sets of 60 breast biopsies (240 total cases, 1 slide per case), including 23 cases of invasive breast cancer, 73 ductal carcinoma in situ (DCIS), 72 with atypical hyperplasia (atypia), and 72 benign cases without atypia. Participants were blinded to the interpretations of other study pathologists and consensus panel members. Among the 3 consensus panel members, unanimous agreement of their independent diagnoses was 75%, and concordance with the consensus-derived reference diagnoses was 90.3%. MAIN OUTCOMES AND MEASURES The proportions of diagnoses overinterpreted and underinterpreted relative to the consensus-derived reference diagnoses were assessed. RESULTS Sixty-five percent of invited, responding pathologists were eligible and consented to participate. Of these, 91% (N = 115) completed the study, providing 6900 individual case diagnoses. Compared with the consensus-derived reference diagnosis, the overall concordance rate of diagnostic interpretations of participating pathologists was 75.3% (95% CI, 73.4%–77.0%; 5194 of 6900 interpretations). Consensus ReferenceDiagnosis Pathologist Interpretation vs Consensus-Derived Reference Diagnosis, % (95% CI) No. ofInterpretations Overall ConcordanceRate OverinterpretationRate UnderinterpretationRate Benign without atypia 2070 87 (85–89) 13 (11–15) Atypia 2070 48 (44–52) 17 (15–21) 35 (31–39) DCIS 2097 84 (82–86) 3 (2–4) 13 (12–15) Invasive carcinoma 663 96 (94–97) 4 (3–6) Disagreement with the reference diagnosis was statistically significantly higher among biopsies from women with higher (n = 122) vs lower (n = 118) breast density on prior mammograms (overall concordance rate, 73% [95% CI, 71%–75%] for higher vs 77% [95% CI, 75%–80%] for lower, P < .001), and among pathologists who interpreted lower weekly case volumes (P < .001) or worked in smaller practices (P = .034) or nonacademic settings (P = .007). CONCLUSIONS AND RELEVANCE In this study of pathologists, in which diagnostic interpretation was based on a single breast biopsy slide, overall agreement between the individual pathologists’ interpretations and the expert consensus–derived reference diagnoses was 75.3%, with the highest level of concordance for invasive carcinoma and lower levels of concordance for DCIS and atypia. Further research is needed to understand the relationship of these findings with patient management. PMID:25781441
National reference doses for dental cephalometric radiography.
Holroyd, J R
2011-12-01
Diagnostic reference levels (DRLs) are an important tool in the optimisation of clinical radiography. Although national DRLs are provided for many diagnostic procedures including dental intra-oral radiography, there are currently no national DRLs set for cephalometric radiography. In the absence of formal national DRLs, the Health Protection Agency (HPA) has previously published National Reference Doses (NRDs) covering a wide range of diagnostic X-ray examinations. The aim of this study was to determine provisional NRDs for cephalometric radiography. Measurements made by the Dental X-ray Protection Service (DXPS) of the HPA, as part of the cephalometric X-ray equipment testing service provided to dentists and dental trade companies throughout the UK, were used to derive provisional NRDs. Dose-area product measurements were made on 42 X-ray sets. Third quartile dose-area product values for adult and child lateral cephalometric radiography were found to be 41 mGy cm² and 25 mGy cm², respectively, with individual measurements ranging from 3 mGy cm² to 108 mGy cm². This report proposes provisional NRDs of 40 mGy cm² and 25 mGy cm² for adult and child lateral cephalometric radiographs, respectively; these doses could be considered by employers when establishing their local DRLs.
Validation of Living Donor Nephrectomy Codes
Lam, Ngan N.; Lentine, Krista L.; Klarenbach, Scott; Sood, Manish M.; Kuwornu, Paul J.; Naylor, Kyla L.; Knoll, Gregory A.; Kim, S. Joseph; Young, Ann; Garg, Amit X.
2018-01-01
Background: Use of administrative data for outcomes assessment in living kidney donors is increasing given the rarity of complications and challenges with loss to follow-up. Objective: To assess the validity of living donor nephrectomy in health care administrative databases compared with the reference standard of manual chart review. Design: Retrospective cohort study. Setting: 5 major transplant centers in Ontario, Canada. Patients: Living kidney donors between 2003 and 2010. Measurements: Sensitivity and positive predictive value (PPV). Methods: Using administrative databases, we conducted a retrospective study to determine the validity of diagnostic and procedural codes for living donor nephrectomies. The reference standard was living donor nephrectomies identified through the province’s tissue and organ procurement agency, with verification by manual chart review. Operating characteristics (sensitivity and PPV) of various algorithms using diagnostic, procedural, and physician billing codes were calculated. Results: During the study period, there were a total of 1199 living donor nephrectomies. Overall, the best algorithm for identifying living kidney donors was the presence of 1 diagnostic code for kidney donor (ICD-10 Z52.4) and 1 procedural code for kidney procurement/excision (1PC58, 1PC89, 1PC91). Compared with the reference standard, this algorithm had a sensitivity of 97% and a PPV of 90%. The diagnostic and procedural codes performed better than the physician billing codes (sensitivity 60%, PPV 78%). Limitations: The donor chart review and validation study was performed in Ontario and may not be generalizable to other regions. Conclusions: An algorithm consisting of 1 diagnostic and 1 procedural code can be reliably used to conduct health services research that requires the accurate determination of living kidney donors at the population level. PMID:29662679
Kanne, Stephen M; Carpenter, Laura Arnstein; Warren, Zachary
2018-05-07
There are many available tools with varying levels of accuracy designed to screen for Autism Spectrum Disorder (ASD) in young children, both in the general population and specifically among those referred for developmental concerns. With burgeoning waitlists for comprehensive diagnostic ASD assessments, finding accurate methods and tools for advancing diagnostic triage becomes increasingly important. The current study compares the efficacy of four oft used paper and pencil measures, the Modified Checklist for Autism in Toddlers Revised with Follow-up, the Social Responsiveness Scale, Second Edition, and the Social Communication Questionnaire, and the Child Behavior Checklist to a novel mobile-health screening tool developed by Cognoa, Inc. (Cognoa) in a group of children 18-72 months of age. The Cognoa tool may have potential benefits as it integrates a series of parent-report questions with remote clinical ratings of brief video segments uploaded via parent's smartphones to calculate level of ASD risk. Participants were referred to one of three tertiary care diagnostic centers for ASD-related concerns (n = 230) and received a best estimate ASD diagnosis. Analysis and comparison of psychometric properties indicated potential advantages for Cognoa within this clinical sample across age ranges not often covered by another single measure/tool. Autism Res 2018. © 2018 International Society for Autism Research, Wiley Periodicals, Inc. With the wait times getting longer for comprehensive Autism Spectrum Disorder (ASD) diagnostic assessments, it is becoming increasingly important to find accurate tools to screen for ASD. The current study compares four screening measures that have been in use for some time to a novel mobile-health screening tool, called Cognoa. The Cognoa tool is novel because it integrates parent-report questions with clinical ratings of brief video segments uploaded via parent's smartphones to calculate ASD risk. Two hundred thirty children who were referred to one of three ASD specialty diagnostic centers to see if they had ASD participated in the study. A direct comparison indicated potential advantages for Cognoa not often covered by another single measure/tool. © 2018 International Society for Autism Research, Wiley Periodicals, Inc.
Strauss, Keith J
2014-10-01
The management of image quality and radiation dose during pediatric CT scanning is dependent on how well one manages the radiographic techniques as a function of the type of exam, type of CT scanner, and patient size. The CT scanner's display of expected CT dose index volume (CTDIvol) after the projection scan provides the operator with a powerful tool prior to the patient scan to identify and manage appropriate CT techniques, provided the department has established appropriate diagnostic reference levels (DRLs). This paper provides a step-by-step process that allows the development of DRLs as a function of type of exam, of actual patient size and of the individual radiation output of each CT scanner in a department. Abdomen, pelvis, thorax and head scans are addressed. Patient sizes from newborns to large adults are discussed. The method addresses every CT scanner regardless of vendor, model or vintage. We cover adjustments to techniques to manage the impact of iterative reconstruction and provide a method to handle all available voltages other than 120 kV. This level of management of CT techniques is necessary to properly monitor radiation dose and image quality during pediatric CT scans.
Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2015-08-01
To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.
Van Arsdell, S W; DiFronzo, F; Backman, K C; Mahler, P H
1996-09-01
OmniGene Diagnostics, Inc. has applied the principles of genetic engineering to develop species-specific DNA probe tests for eight periodontal pathogens (Porphyromonas gingivalis, Prevotella intermedia, Actinobacillus actinomycetem-comitans, Fusobacterium nucleatum, Eikenella corrodens, Campylobacter rectus, Bacteroides forsythus, and Treponema denticola). The test requires minimal effort on the part of the clinician: subgingival plaque samples are collected from the patient and sent through the mail for analysis by OmniGene Diagnostics' fully licensed clinical reference laboratory. Results are transmitted to the practitioner by phone, fax, or mail. The use of diagnostic tests for periodontal pathogens is a relatively new concept in dentistry and acceptance of the OmniGene Diagnostics tests by the dental marketplace has been slower than anticipated. OmniGene Diagnostics' challenge for the future is to persuade the dental community that monitoring periodontal pathogen levels, as well as other clinical indicators of disease, is essential to providing optimal care to the periodontitis patient.
Thorne, John C; Coggins, Truman E; Carmichael Olson, Heather; Astley, Susan J
2007-04-01
To evaluate classification accuracy and clinical feasibility of a narrative analysis tool for identifying children with a fetal alcohol spectrum disorder (FASD). Picture-elicited narratives generated by 16 age-matched pairs of school-aged children (FASD vs. typical development [TD]) were coded for semantic elaboration and reference strategy by judges who were unaware of age, gender, and group membership of the participants. Receiver operating characteristic (ROC) curves were used to examine the classification accuracy of the resulting set of narrative measures for making 2 classifications: (a) for the 16 children diagnosed with FASD, low performance (n = 7) versus average performance (n = 9) on a standardized expressive language task and (b) FASD (n = 16) versus TD (n = 16). Combining the rates of semantic elaboration and pragmatically inappropriate reference perfectly matched a classification based on performance on the standardized language task. More importantly, the rate of ambiguous nominal reference was highly accurate in classifying children with an FASD regardless of their performance on the standardized language task (area under the ROC curve = .863, confidence interval = .736-.991). Results support further study of the diagnostic utility of narrative analysis using discourse level measures of elaboration and children's strategic use of reference.
El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas
2014-01-01
Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard. PMID:24218531
Tamimi, Waleed; Albanyan, Esam; Altwaijri, Yasmin; Tamim, Hani; Alhussein, Fahad
2012-04-01
Reference intervals for pubertal characteristics are influenced by genetic, geographic, dietary and socioeconomic factors. Therefore, the aim of this study was to establish age-specific reference intervals of glucose and lipid levels among local school children. This was cross-sectional study, conducted among Saudi school children. Fasting blood samples were collected from 2149 children, 1138 (53%) boys and 1011 (47%) girls, aged 6 to 18 years old. Samples were analyzed on the Architect c8000 Chemistry System (Abbott Diagnostics, USA) for glucose, cholesterol, triglycerides, HDL and LDL. Reference intervals were established by nonparametric methods between the 2.5th and 97.5th percentiles. Significant differences were observed between boys and girls for cholesterol and triglycerides levels in all age groups (P < 0.02). Only at age 6-7 years and at adolescents, HDL and LDL levels were found to be significant (P < 0.001). No significant differences were seen in glucose levels except at age 12 to 13 years. Saudi children have comparable serum cholesterol levels than their Western counterparts. This may reflect changing dietary habits and increasing affluence in Saudi Arabia. Increased lipid screening is anticipated, and these reference intervals will aid in the early assessment of cardiovascular and diabetes risk in Saudi pediatric populations.
Prevalence of Autism Spectrum Disorder in Children Referred for Diagnostic Autism Evaluation.
Monteiro, Sonia A; Spinks-Franklin, Adiaha; Treadwell-Deering, Diane; Berry, Leandra; Sellers-Vinson, Sherry; Smith, Eboni; Proud, Monica; Voigt, Robert G
2015-12-01
Increased public awareness of autism spectrum disorders (ASD) and routine screening in primary care have contributed to increased requests for diagnostic ASD evaluations. However, given the scarcity of subspecialty autism diagnostic resources, overreferral of children suspected of having ASD may be contributing to long waiting lists at tertiary care autism centers and delaying diagnosis for those children who truly have ASD. To determine whether children are being excessively referred to ASD-specific diagnostic clinics, our objective was to determine the prevalence of true ASD diagnoses in children referred for diagnostic ASD evaluation. Charts of all patients referred to a regional autism center between April 2011 and August 2012 for suspicion of a possible ASD were retrospectively reviewed and demographic and clinical diagnoses abstracted. Only 214 of 348 patients evaluated (61%) received an ASD diagnosis. Thus, concerns about autism are not confirmed by an ASD diagnosis in a significant number of children. © The Author(s) 2015.
Diagnostic performance of a commercial immunoblot assay for myositis antibody testing.
Bundell, Chris; Rojana-Udomsart, Arada; Mastaglia, Frank; Hollingsworth, Peter; McLean-Tooke, Andrew
2016-06-01
The objective of this study was to establish a population based reference range for a commercial immunoblot assay detecting myositis specific autoantibodies (MSAs) and myositis associated autoantibodies (MAAs), and to assess the diagnostic performance of this reference range against the manufacturer's recommended ranges in a myositis patient cohort. A total of 124 patients from a myositis cohort and 197 healthy controls were serologically assessed using a commercial immunoblot containing eleven autoantigens (Jo-1, EJ, OJ, PL7, PL12, Mi-2, SRP, Ku, PMScl75, PMScl100 and Ro52) according to the manufacturer's instructions. Use of the manufacturer's reference ranges resulted in detection of MSAs in 19.4% of myositis patients and 9.1% of controls; MAAs were detected in 41.1% of myositis patients and 14.2% of controls. Reference values derived from the healthy control population resulted in significant differences in cut-off values for some autoantibodies, particularly Ro52 and PMScl75. Use of local reference ranges reduced detection of MSAs to 16.9% of myositis patients and 3% of healthy controls, with MAAs 23.4% of patients and 2% of healthy controls. Application of population based reference ranges resulted in significant differences in detection of MSAs and MAAs compared to the manufacturer's recommended ranges. Cut-off levels should be assessed to ensure suitability for the population tested. Copyright © 2016. Published by Elsevier B.V.
The INTELSAT VI SSTDMA network diagnostic system
NASA Astrophysics Data System (ADS)
Tamboli, Satish P.; Zhu, Xiaobo; Wilkins, Kim N.; Gupta, Ramesh K.
The system-level design of an expert-system-based, near-real-time diagnostic system for INTELSAT VI satellite-switched time-division multiple access (SSTDMA) network is described. The challenges of INTELSAT VI diagnostics are discussed, along with alternative approaches for network diagnostics and the rationale for choosing a method based on burst unique-word detection. The focal point of the diagnostic system is the diagnostic processor, which resides in the central control and monitoring facility known as the INTELSAT Operations Center TDMA Facility (IOCTF). As real-time information such as burst unique-word detection data, reference terminal status data, and satellite telemetry alarm data are received at the IOCTF, the diagnostic processor continuously monitors the data streams. When a burst status change is detected, a 'snapshot' of the real-time data is forwarded to the expert system. Receipt of the change causes a set of rules to be invoked which associate the traffic pattern with a set of probable causes. A user-friendly interface allows a graphical view of the burst time plan and provides the ability to browse through the knowledge bases.
Metcalfe, C; Evans, S; Ibrahim, F; Patel, B; Anson, K; Chinegwundoh, F; Corbishley, C; Gillatt, D; Kirby, R; Muir, G; Nargund, V; Popert, R; Persad, R; Ben-Shlomo, Y
2008-01-01
Black men in England have three times the age-adjusted incidence of diagnosed prostate cancer as compared with their White counterparts. This population-based retrospective cohort study is the first UK-based investigation of whether access to diagnostic services underlies the association between race and prostate cancer. Prostate cancer was ascertained using multiple sources including hospital records. Race and factors that may influence prostate cancer diagnosis were assessed by questionnaire and hospital records review. We found that Black men were diagnosed an average of 5.1 years younger as compared with White men (P<0.001). Men of both races were comparable in their knowledge of prostate cancer, in the delays reported before presentation, and in their experience of co-morbidity and symptoms. Black men were more likely to be referred for diagnostic investigation by a hospital department (P=0.013), although general practitioners referred the large majority of men. Prostate-specific antigen levels were comparable at diagnosis, although Black men had higher levels when compared with same-age White men (P<0.001). In conclusion, we found no evidence of Black men having poorer access to diagnostic services. Differences in the run-up to diagnosis are modest and seem insufficient to explain the higher rate of prostate cancer diagnosis in Black men. PMID:18797456
Implementation of a National Reference Laboratory for Buruli Ulcer Disease in Togo
Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl–Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela
2013-01-01
Background In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Methodology Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions “Maritime” and “Central,” standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. Principal Findings The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. Conclusions High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory. PMID:23359828
Implementation of a national reference laboratory for Buruli ulcer disease in Togo.
Beissner, Marcus; Huber, Kristina Lydia; Badziklou, Kossi; Halatoko, Wemboo Afiwa; Maman, Issaka; Vogel, Felix; Bidjada, Bawimodom; Awoussi, Koffi Somenou; Piten, Ebekalisai; Helfrich, Kerstin; Mengele, Carolin; Nitschke, Jörg; Amekuse, Komi; Wiedemann, Franz Xaver; Diefenhardt, Adolf; Kobara, Basile; Herbinger, Karl-Heinz; Kere, Abiba Banla; Prince-David, Mireille; Löscher, Thomas; Bretzel, Gisela
2013-01-01
In a previous study PCR analysis of clinical samples from suspected cases of Buruli ulcer disease (BUD) from Togo and external quality assurance (EQA) for local microscopy were conducted at an external reference laboratory in Germany. The relatively poor performance of local microscopy as well as effort and time associated with shipment of PCR samples necessitated the implementation of stringent EQA measures and availability of local laboratory capacity. This study describes the approach to implementation of a national BUD reference laboratory in Togo. Large scale outreach activities accompanied by regular training programs for health care professionals were conducted in the regions "Maritime" and "Central," standard operating procedures defined all processes in participating laboratories (regional, national and external reference laboratories) as well as the interaction between laboratories and partners in the field. Microscopy was conducted at regional level and slides were subjected to EQA at national and external reference laboratories. For PCR analysis, sample pairs were collected and subjected to a dry-reagent-based IS2404-PCR (DRB-PCR) at national level and standard IS2404 PCR followed by IS2404 qPCR analysis of negative samples at the external reference laboratory. The inter-laboratory concordance rates for microscopy ranged from 89% to 94%; overall, microscopy confirmed 50% of all suspected BUD cases. The inter-laboratory concordance rate for PCR was 96% with an overall PCR case confirmation rate of 78%. Compared to a previous study, the rate of BUD patients with non-ulcerative lesions increased from 37% to 50%, the mean duration of disease before clinical diagnosis decreased significantly from 182.6 to 82.1 days among patients with ulcerative lesions, and the percentage of category III lesions decreased from 30.3% to 19.2%. High inter-laboratory concordance rates as well as case confirmation rates of 50% (microscopy), 71% (PCR at national level), and 78% (including qPCR confirmation at external reference laboratory) suggest high standards of BUD diagnostics. The increase of non-ulcerative lesions, as well as the decrease in diagnostic delay and category III lesions, prove the effect of comprehensive EQA and training measures involving also procedures outside the laboratory.
Casey, R; Griffin, T P; Wall, D; Dennedy, M C; Bell, M; O'Shea, P M
2017-01-01
Background The Endocrine Society Clinical Practice Guideline on Phaeochomocytoma and Paraganglioma recommends phlebotomy for plasma-free metanephrines with patients fasted and supine using appropriately defined reference intervals. Studies have shown higher diagnostic sensitivities using these criteria. Further, with seated-sampling protocols, for result interpretation, reference intervals that do not compromise diagnostic sensitivity should be employed. Objective To determine the impact on diagnostic performance and financial cost of using supine reference intervals for result interpretation with our current plasma-free metanephrines fasted/seated-sampling protocol. Methods We conducted a retrospective cohort study of patients who underwent screening for PPGL using plasma-free metanephrines from 2009 to 2014 at Galway University Hospitals. Plasma-free metanephrines were measured using liquid chromatography-tandem mass spectrometry. Supine thresholds for plasma normetanephrine and metanephrine set at 610 pmol/L and 310 pmol/L, respectively, were used. Results A total of 183 patients were evaluated. Mean age of participants was 53.4 (±16.3) years. Five of 183 (2.7%) patients had histologically confirmed PPGL (males, n=4). Using seated reference intervals for plasma-free metanephrines, diagnostic sensitivity and specificity were 100% and 98.9%, respectively, with two false-positive cases. Application of reference intervals established in subjects supine and fasted to this cohort gave diagnostic sensitivity of 100% with specificity of 74.7%. Financial analysis of each pretesting strategy demonstrated cost-equivalence (€147.27/patient). Conclusion Our cost analysis, together with the evidence that fasted/supine-sampling for plasma-free metanephrines, offers more reliable exclusion of PPGL mandates changing our current practice. This study highlights the important advantages of standardized diagnostic protocols for plasma-free metanephrines to ensure the highest diagnostic accuracy for investigation of PPGL.
Downs, Sara H; Parry, Jessica E; Upton, Paul A; Broughan, Jennifer M; Goodchild, Anthony V; Nuñez-Garcia, Javier; Greiner, Matthias; Abernethy, Darrell A; Cameron, Angus R; Cook, Alasdair J; de la Rua-Domenech, Ricardo; Gunn, Jane; Pritchard, Elizabeth; Rhodes, Shelley; Rolfe, Simon; Sharp, Michael; Vordermeier, H Martin; Watson, Eamon; Welsh, Michael; Whelan, Adam O; Woolliams, John A; More, Simon J; Clifton-Hadley, Richard S
2018-05-01
A systematic review was conducted to identify studies with data for statistical meta-analyses of sensitivity (Se) and specificity (Sp) of ante-mortem and post-mortem diagnostic tests for bovine tuberculosis (bTB) in cattle. Members of a working group (WG) developed and tested search criteria and developed a standardised two-stage review process, to identify primary studies with numerator and denominator data for test performance and an agreed range of covariate data. No limits were applied to year, language, region or type of test in initial searches of electronic databases. In stage 1, titles and available abstracts were reviewed. References that complied with stage 1 selection criteria were reviewed in entirety and agreed data were extracted from references that complied with stage 2 selection criteria. At stage 1, 9782 references were reviewed and 261 (2.6%) passed through to stage 2 where 215 English language references were each randomly allocated to two of 18 WG reviewers and 46 references in other languages were allocated to native speakers. Agreement regarding eligibility between reviewers of the same reference at stage 2 was moderate (Kappa statistic = 0.51) and a resolution procedure was conducted. Only 119 references (published 1934-2009) were identified with eligible performance estimates for one or more of 14 different diagnostic test types; despite a comprehensive search strategy and the global impact of bTB. Searches of electronic databases for diagnostic test performance data were found to be nonspecific with regard to identifying references with diagnostic test Se or Sp data. Guidelines for the content of abstracts to research papers reporting diagnostic test performance are presented. The results of meta-analyses of the sensitivity and specificity of the tests, and of an evaluation of the methodological quality of the source references, are presented in accompanying papers (Nuñez-Garcia et al., 2017; Downs et al., 2017). Copyright © 2017. Published by Elsevier B.V.
Wålinder, Olov
The symptoms of primary adrenocortical insufficiency (Addison's disease) such as fatigue, anorexia, hypotension and hyperpigmentation are similar to those of normal pregnancy. Addison's disease is rare and the diagnosis can easily be overlooked during pregnancy. The concentration of corticosteroid-binding globulin (CBG) and cortisol in serum as well as urinary free cortisol increase 2-3 times during pregnancy. Therefore, the reference ranges for nonpregnant persons cannot be used during pregnancy. The diagnosis of Addison's disease in pregnancy should be based on analysis of p-ACTH which remains within the reference range in normal pregnancy until delivery. A case of Addison's disease diagnosed during pregnancy is presented and it illustrates the diagnostic difficulties. In patients taking oral estrogen containing contraceptives, serum levels of CBG and cortisol also increase 2-3 times, making s-cortisol values difficult to interpret. Also in these patients, analysis of p-ACTH is of value when suspecting Addison's disease.
Radiation Safety in Nuclear Medicine Procedures.
Cho, Sang-Geon; Kim, Jahae; Song, Ho-Chun
2017-03-01
Since the nuclear disaster at the Fukushima Daiichi Nuclear Power Plant in 2011, radiation safety has become an important issue in nuclear medicine. Many structured guidelines or recommendations of various academic societies or international campaigns demonstrate important issues of radiation safety in nuclear medicine procedures. There are ongoing efforts to fulfill the basic principles of radiation protection in daily nuclear medicine practice. This article reviews important principles of radiation protection in nuclear medicine procedures. Useful references, important issues, future perspectives of the optimization of nuclear medicine procedures, and diagnostic reference level are also discussed.
Zeleny, Reinhard; Nia, Yacine; Schimmel, Heinz; Mutel, Isabelle; Hennekinne, Jacques-Antoine; Emteborg, Håkan; Charoud-Got, Jean; Auvray, Frédéric
2016-08-01
Staphylococcal enterotoxins (SEs) account for a substantial number of food-poisoning outbreaks. European legislation (Commission Regulation 1441/2007) stipulates the reference procedure for SE analysis in milk and dairy products, which is based on extraction, dialysis concentration and immunochemical detection using one of two approved assays (VIDAS(®) SET2, Ridascreen(®) SET Total). However, certified reference materials (CRMs) are lacking to support laboratories in performing reliable detection of Staphylococcus aureus enterotoxin A (SEA) in relevant matrices at sub-nanogram per gram levels. The certification of a set of three reference materials (blank and two SEA-containing materials) for testing of the presence/absence of SEA in cheese is described. The reference procedure was applied in an intercomparison with 15 laboratories, and results were reported in a qualitative manner (presence or absence of SEA in the sample). No false-negative or false-positive results were obtained. The certified values were stated as diagnostic specificity (blank material) or diagnostic sensitivity (SEA-containing materials) and were 100 % in all cases. Stability studies demonstrated suitable material stability when stored cooled or frozen. An in-house study on the recovery of SEA in the cheese materials using a double-sandwich enzyme-linked immunosorbent assay (ELISA) revealed comparable recovery values of around 45 % at the two spiking levels and in both the SEA-containing CRMs as well as blank CRM freshly spiked prior to analysis. The values were also comparable over time and among different analysts. The materials provide valuable support to laboratories for method validation and method performance verification and will increase the reliability of measuring SEA in cheese.
Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth
2015-01-01
Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275
Bakker, Anne; Schrieken, Bart A.L.; Hoofwijk, Marthe C.; Olff, Miranda
2017-01-01
Abstract To facilitate easily accessible screening for trauma‐related symptoms, a web‐based application called Smart Assessment on your Mobile (SAM) was developed. In this study, we examined whether SAM was able to accurately identify posttraumatic stress disorder (PTSD) and depression in adults. Eighty‐nine referred police officers completed SAM, containing the PTSD Checklist for Diagnostic and Statistical Manual of Mental Disorders (DSM)‐5 (PCL‐5) and the Depression Anxiety and Stress Scale (DASS‐21), on their own device prior to a diagnostic interview where the Clinician‐Administered PTSD Scale for DSM‐5 (CAPS‐5) and Structured Clinical Interview for DSM‐IV (SCID‐I/P) were administered. Results showed a substantial agreement between SAM and the diagnostic interview in the assessment of PTSD and depression. An optimal trade‐off between sensitivity (89%) and specificity (68%) levels was found at a cut‐off score of 31 on the PTSD Checklist for DSM‐5 (area under the curve = 0.845, 95% CI [0.765, 0.925], diagnostic odds ratio = 15.97). This is one of the first studies to support the validity and reliability of a mobile screener following trauma. SAM may facilitate screening for trauma‐related symptoms on a large scale and could be a first step in a stepped‐care model for trauma survivors to help identify individuals who need further diagnostics and care. PMID:28948699
Autism spectrum and attention-deficit disorders in girls. Some neuropsychological aspects.
Nydén, A; Hjelmquist, E; Gillberg, C
2000-09-01
This study compared the neuropsychological test profiles of non-mentally retarded girls and boys consecutively referred to a neuropsychiatric clinic and those of contrast cases of girls from mainstream classrooms of one Göteborg school district. To avoid overreliance on the male prototype with regard to diagnostic criteria the clinical group comprised a mixed sample of girls and boys without diagnostic subgrouping. Clinic girls had a lower IQ than comparison girls. Girls were more impaired than the boys with respect to executive functions and scored less well on theory of mind tasks. Previous studies have shown girls with autism and mental retardation to be more severely affected than boys both with regard to level of intellectual functioning and overall measures of brain dysfunction. The present study indicates that clinic girls with a variety of neuropsychiatric disorders at higher levels of intellectual functioning (some of which met diagnostic criteria for autism spectrum disorder) may also be more severely affected than boys with corresponding types of "surface" problems.
Reference interval for thyrotropin in a ultrasonography screened Korean population
Kim, Mijin; Kim, Soo Han; Lee, Yunkyoung; Park, Su-yeon; Kim, Hyung-don; Kwon, Hyemi; Choi, Yun Mi; Jang, Eun Kyung; Jeon, Min Ji; Kim, Won Gu; Shong, Young Kee; Kim, Won Bae
2015-01-01
Background/Aims The diagnostic accuracy of thyroid dysfunctions is primarily affected by the validity of the reference interval for serum thyroid-stimulating hormone (TSH). Thus, the present study aimed to establish a reference interval for TSH using a normal Korean population. Methods This study included 19,465 subjects who were recruited after undergoing routine health check-ups. Subjects with overt thyroid disease, a prior history of thyroid disease, or a family history of thyroid cancer were excluded from the present analyses. The reference range for serum TSH was evaluated in a normal Korean reference population which was defined according to criteria based on the guidelines of the National Academy of Clinical Biochemistry, ultrasound (US) findings, and smoking status. Sex and age were also taken into consideration when evaluating the distribution of serum TSH levels in different groups. Results In the presence of positive anti-thyroid peroxidase antibodies or abnormal US findings, the central 95 percentile interval of the serum TSH levels was widened. Additionally, the distribution of serum TSH levels shifted toward lower values in the current smokers group. The reference interval for TSH obtained using a normal Korean reference population was 0.73 to 7.06 mIU/L. The serum TSH levels were higher in females than in males in all groups, and there were no age-dependent shifts. Conclusions The present findings demonstrate that the serum TSH reference interval in a normal Korean reference population was higher than that in other countries. This result suggests that the upper and lower limits of the TSH reference interval, which was previously defined by studies from Western countries, should be raised for Korean populations. PMID:25995664
He, Qiwei; Glas, Cees A W; Veldkamp, Bernard P
2014-06-01
This article explores the generalizability of the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV) diagnostic criteria for post-traumatic stress disorder (PTSD) to various subpopulations. Besides identifying the differential symptom functioning (also referred to as differential item functioning [DIF]) related to various background variables such as gender, marital status and educational level, this study emphasizes the importance of evaluating the impact of DIF on population inferences as made in health surveys and clinical trials, and on the diagnosis of individual patients. Using a sample from the National Comorbidity Study-Replication (NCS-R), four symptoms for gender, one symptom for marital status, and three symptoms for educational level were significantly flagged as DIF, but their impact on diagnosis was fairly small. We conclude that the DSM-IV diagnostic criteria for PTSD do not produce substantially biased results in the investigated subpopulations, and there should be few reservations regarding their use. Further, although the impact of DIF (i.e. the influence of differential symptom functioning on diagnostic results) was found to be quite small in the current study, we recommend that diagnosticians always perform a DIF analysis of various subpopulations using the methodology presented here to ensure the diagnostic criteria is valid in their own studies. Copyright © 2014 John Wiley & Sons, Ltd.
Diagnostic concordance among pathologists interpreting breast biopsy specimens.
Elmore, Joann G; Longton, Gary M; Carney, Patricia A; Geller, Berta M; Onega, Tracy; Tosteson, Anna N A; Nelson, Heidi D; Pepe, Margaret S; Allison, Kimberly H; Schnitt, Stuart J; O'Malley, Frances P; Weaver, Donald L
2015-03-17
A breast pathology diagnosis provides the basis for clinical treatment and management decisions; however, its accuracy is inadequately understood. To quantify the magnitude of diagnostic disagreement among pathologists compared with a consensus panel reference diagnosis and to evaluate associated patient and pathologist characteristics. Study of pathologists who interpret breast biopsies in clinical practices in 8 US states. Participants independently interpreted slides between November 2011 and May 2014 from test sets of 60 breast biopsies (240 total cases, 1 slide per case), including 23 cases of invasive breast cancer, 73 ductal carcinoma in situ (DCIS), 72 with atypical hyperplasia (atypia), and 72 benign cases without atypia. Participants were blinded to the interpretations of other study pathologists and consensus panel members. Among the 3 consensus panel members, unanimous agreement of their independent diagnoses was 75%, and concordance with the consensus-derived reference diagnoses was 90.3%. The proportions of diagnoses overinterpreted and underinterpreted relative to the consensus-derived reference diagnoses were assessed. Sixty-five percent of invited, responding pathologists were eligible and consented to participate. Of these, 91% (N = 115) completed the study, providing 6900 individual case diagnoses. Compared with the consensus-derived reference diagnosis, the overall concordance rate of diagnostic interpretations of participating pathologists was 75.3% (95% CI, 73.4%-77.0%; 5194 of 6900 interpretations). Among invasive carcinoma cases (663 interpretations), 96% (95% CI, 94%-97%) were concordant, and 4% (95% CI, 3%-6%) were underinterpreted; among DCIS cases (2097 interpretations), 84% (95% CI, 82%-86%) were concordant, 3% (95% CI, 2%-4%) were overinterpreted, and 13% (95% CI, 12%-15%) were underinterpreted; among atypia cases (2070 interpretations), 48% (95% CI, 44%-52%) were concordant, 17% (95% CI, 15%-21%) were overinterpreted, and 35% (95% CI, 31%-39%) were underinterpreted; and among benign cases without atypia (2070 interpretations), 87% (95% CI, 85%-89%) were concordant and 13% (95% CI, 11%-15%) were overinterpreted. Disagreement with the reference diagnosis was statistically significantly higher among biopsies from women with higher (n = 122) vs lower (n = 118) breast density on prior mammograms (overall concordance rate, 73% [95% CI, 71%-75%] for higher vs 77% [95% CI, 75%-80%] for lower, P < .001), and among pathologists who interpreted lower weekly case volumes (P < .001) or worked in smaller practices (P = .034) or nonacademic settings (P = .007). In this study of pathologists, in which diagnostic interpretation was based on a single breast biopsy slide, overall agreement between the individual pathologists' interpretations and the expert consensus-derived reference diagnoses was 75.3%, with the highest level of concordance for invasive carcinoma and lower levels of concordance for DCIS and atypia. Further research is needed to understand the relationship of these findings with patient management.
Guldbrandt, Louise Mahncke; Fenger-Grøn, Morten; Rasmussen, Torben Riis; Jensen, Henry; Vedsted, Peter
2015-01-22
Lung cancer stage at diagnosis predicts possible curative treatment. In Denmark and the UK, lung cancer patients have lower survival rates than citizens in most other European countries, which may partly be explained by a comparatively longer diagnostic interval in these two countries. In Denmark, a pathway was introduced in 2008 allowing general practitioners (GPs) to refer patients suspected of having lung cancer directly to fast-track diagnostics. However, symptom presentation of lung cancer in general practice is known to be diverse and complex, and systematic knowledge of the routes to diagnosis is needed to enable earlier lung cancer diagnosis in Denmark. This study aims to describe the routes to diagnosis, the diagnostic activity preceding diagnosis and the diagnostic intervals for lung cancer in the Danish setting. We conducted a national registry-based cohort study on 971 consecutive incident lung cancer patients in 2010 using data from national registries and GP questionnaires. GPs were involved in 68.3% of cancer patients' diagnostic pathways, and 27.4% of lung cancer patients were referred from the GP to fast-track diagnostic work-up. A minimum of one X-ray was performed in 85.6% of all cases before diagnosis. Patients referred through a fast-track route more often had diagnostic X-rays (66.0%) than patients who did not go through fast-track (49.4%). Overall, 33.6% of all patients had two or more X-rays performed during the 90 days before diagnosis. Patients whose symptoms were interpreted as non-alarm symptoms or who were not referred to fast-track were more likely to experience a long diagnostic interval than patients whose symptoms were interpreted as alarm symptoms or who were referred to fast-track. Lung cancer patients followed several diagnostic pathways. The existing fast-track pathway must be supplemented to ensure earlier detection of lung cancer. The high incidence of multiple X-rays warrants a continued effort to develop more accurate lung cancer tests for use in primary care.
Value of percutaneous needle biopsy of small renal tumors in patients referred for cryoablation.
Iguchi, Toshihiro; Hiraki, Takao; Gobara, Hideo; Fujiwara, Hiroyasu; Sakurai, Jun; Matsui, Yusuke; Araki, Motoo; Nasu, Yasutomo; Kanazawa, Susumu
2017-04-01
To retrospectively evaluate the safety and diagnostic yield of needle biopsy of small renal tumors, and the clinical consequences of performing needle biopsy in patients referred for percutaneous cryoablation before their treatment. Biopsy was performed for 120 tumors (mean diameter, 2.2 cm) in 119 patients. All procedures were divided into diagnostic and non-diagnostic biopsies. Various variables were compared between the two groups. All cryoablation procedures were divided into two groups: procedures with or without simultaneous biopsy. The rates of benign or non-diagnostic tumors in each group were compared. After performing 120 initial and eight repeat biopsies, Grade 1 bleedings occurred in 44 cases. Six tumors were non-diagnostic and 114 were pathologically diagnosed. There were no significant variables between the diagnostic and non-diagnostic biopsies. Unnecessary cryoablation was avoided in nine benign lesions by performing biopsy in advance. Cryoablation performed simultaneously with biopsy included significantly more benign or non-diagnostic tumors than cryoablation performed after biopsy (15.2% vs. 1.4%; p = .01). Percutaneous biopsy of small renal tumors referred for cryoablation was a safe procedure with high diagnostic yield. The confirmation of pathological diagnosis prior to cryoablation is necessary because patients with benign tumors can avoid unnecessary treatment.
Quality systems in veterinary diagnostics laboratories.
de Branco, Freitas Maia L M
2007-01-01
Quality assurance of services provided by veterinary diagnostics laboratories is a fundamental element promoted by international animal health organizations to establish trust, confidence and transparency needed for the trade of animals and their products at domestic and international levels. It requires, among other things, trained personnel, consistent and rigorous methodology, choice of suitable methods as well as appropriate calibration and traceability procedures. An important part of laboratory quality management is addressed by ISO/IEC 17025, which aims to facilitate cooperation among laboratories and their associated parties by assuring the generation of credible and consistent information derived from analytical results. Currently, according to OIE recommendation, veterinary diagnostics laboratories are only subject to voluntary compliance with standard ISO/IEC 17025; however, it is proposed here that OIE reference laboratories and collaboration centres strongly consider its adoption.
Thomas, P; Hayton, A; Beveridge, T; Marks, P; Wallace, A
2015-09-01
To assess the influence and significance of the use of iterative reconstruction (IR) algorithms on patient dose in CT in Australia. We examined survey data submitted to the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) National Diagnostic Reference Level Service (NDRLS) during 2013 and 2014. We compared median survey dose metrics with categorization by scan region and use of IR. The use of IR results in a reduction in volume CT dose index of between 17% and 44% and a reduction in dose-length product of between 14% and 34% depending on the specific scan region. The reduction was highly significant (p < 0.001, Wilcoxon rank-sum test) for all six scan regions included in the NDRLS. Overall, 69% (806/1167) of surveys included in the analysis used IR. The use of IR in CT is achieving dose savings of 20-30% in routine practice in Australia. IR appears to be widely used by participants in the ARPANSA NDRLS with approximately 70% of surveys submitted employing this technique. This study examines the impact of the use of IR on patient dose in CT on a national scale.
Michaud, Ginette Y
2005-01-01
In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.
Xiao, Li; Saldivar, Juan-Sebastian; Zhou, Cuilan; Chen, Chengli; Zhang, Jia; Sirois, Pierre; Li, Kai
2009-02-01
We propose a short definition of The full complement of genetic materials possessed by an intracellular parasite, a cell, or an organism. Accordingly, the human genome is the entire complement of inherited genetic materials possessed by an individual person, or possessed by a cell in an individual person. For higher species, the genomic makeup includes DNA in the nucleus and in the organelles regardless of the number of chromosomes and the homoplasmic or heteroplasmic status of the mitochondrial or chloroplastic DNA. Practically, GENOME can be referred to at the molecular, cellular, individual, and species levels, which has various implications in biotechnological research and molecular diagnostics.
NASA Astrophysics Data System (ADS)
Krupka, M.; Kalal, M.; Dostal, J.; Dudzak, R.; Juha, L.
2017-08-01
Classical interferometry became widely used method of active optical diagnostics. Its more advanced version, allowing reconstruction of three sets of data from just one especially designed interferogram (so called complex interferogram) was developed in the past and became known as complex interferometry. Along with the phase shift, which can be also retrieved using classical interferometry, the amplitude modifications of the probing part of the diagnostic beam caused by the object under study (to be called the signal amplitude) as well as the contrast of the interference fringes can be retrieved using the complex interferometry approach. In order to partially compensate for errors in the reconstruction due to imperfections in the diagnostic beam intensity structure as well as for errors caused by a non-ideal optical setup of the interferometer itself (including the quality of its optical components), a reference interferogram can be put to a good use. This method of interferogram analysis of experimental data has been successfully implemented in practice. However, in majority of interferometer setups (especially in the case of the ones employing the wavefront division) the probe and the reference part of the diagnostic beam would feature different intensity distributions over their respective cross sections. This introduces additional error into the reconstruction of the signal amplitude and the fringe contrast, which cannot be resolved using the reference interferogram only. In order to deal with this error it was found that additional separately recorded images of the intensity distribution of the probe and the reference part of the diagnostic beam (with no signal present) are needed. For the best results a sufficient shot-to-shot stability of the whole diagnostic system is required. In this paper, efficiency of the complex interferometry approach for obtaining the highest possible accuracy of the signal amplitude reconstruction is verified using the computer generated complex and reference interferograms containing artificially introduced intensity variations in the probe and the reference part of the diagnostic beam. These sets of data are subsequently analyzed and the errors of the signal amplitude reconstruction are evaluated.
Monahan, Mark; Barton, Pelham; Taylor, Clare J; Roalfe, Andrea K; Hobbs, F D Richard; Cowie, Martin; Davis, Russell; Deeks, Jon; Mant, Jonathan; McCahon, Deborah; McDonagh, Theresa; Sutton, George; Tait, Lynda
2017-08-15
Detection and treatment of heart failure (HF) can improve quality of life and reduce premature mortality. However, symptoms such as breathlessness are common in primary care, have a variety of causes and not all patients require cardiac imaging. In systems where healthcare resources are limited, ensuring those patients who are likely to have HF undergo appropriate and timely investigation is vital. A decision tree was developed to assess the cost-effectiveness of using the MICE (Male, Infarction, Crepitations, Edema) decision rule compared to other diagnostic strategies to identify HF patients presenting to primary care. Data from REFER (REFer for EchocaRdiogram), a HF diagnostic accuracy study, was used to determine which patients received the correct diagnosis decision. The model adopted a UK National Health Service (NHS) perspective. The current recommended National Institute for Health and Care Excellence (NICE) guidelines for identifying patients with HF was the most cost-effective option with a cost of £4400 per quality adjusted life year (QALY) gained compared to a "do nothing" strategy. That is, patients presenting with symptoms suggestive of HF should be referred straight for echocardiography if they had a history of myocardial infarction or if their NT-proBNP level was ≥400pg/ml. The MICE rule was more expensive and less effective than the other comparators. Base-case results were robust to sensitivity analyses. This represents the first cost-utility analysis comparing HF diagnostic strategies for symptomatic patients. Current guidelines in England were the most cost-effective option for identifying patients for confirmatory HF diagnosis. The low number of HF with Reduced Ejection Fraction patients (12%) in the REFER patient population limited the benefits of early detection. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Wang, Lin; Hui, Stanley Sai-chuen
2015-08-20
Various body weight and height-based references are used to define obese children and adolescents. However, no study investigating the diagnostic accuracies of the definitions of obesity and overweight in Hong Kong Chinese children and adolescents has been conducted. The current study aims to investigate the diagnostic accuracy of BMI-based definitions and 1993 HK reference in screening excess body fat among Hong Kong Chinese children and adolescents. A total of 2,134 participants (1,135 boys and 999 girls) were recruited from local schools. The foot-to-foot BIA scale was applied to assess %BF using standard methods. The criterion of childhood obesity (i.e., overfat) was defined as over 25 %BF for boys and over 30 %BF for girls. Childhood obesity was also determined from four BMI-based references and the 1993 HK reference. The diagnostic accuracy of these existing definitions for childhood obesity in screening excess body fat was evaluated using diagnostic indices. Overall, %BF was significantly correlated with anthropometry measurements in both genders (in boys, r = 0.747 for BMI 0.766 for PWH; in girls, r = 0.930 for BMI 0.851 for PWH). The prevalence rates of overweight and obesity determined by BMI-based references were similar with the prevalence rates of obesity in the 1993 HK reference in both genders. All definitions for childhood obesity showed low sensitivity (in boys, 0.325-0.761; in girls, 0.128-0.588) in detecting overfat. Specificities were high for cut-offs among all definitions for childhood obesity (in boys, 0.862-0.980; in girls, 0.973-0.998). In conclusion, prevalence rates of childhood obesity or overweight varied widely according to the diagnostic references applied. The diagnostic performance for weight and height-based references for obesity is poorer than expected for both genders among Hong Kong Chinese children and adolescents. In order to improve the diagnosis accuracy of childhood obesity, either cut-off values of body weight and height-based definitions of childhood obesity should be revised to increase the sensitivity or the possibility of using other indirect methods of estimating the %BF should be explored.
Kelly, Brendan S; Rainford, Louise A; Darcy, Sarah P; Kavanagh, Eoin C; Toomey, Rachel J
2016-07-01
Purpose To investigate the development of chest radiograph interpretation skill through medical training by measuring both diagnostic accuracy and eye movements during visual search. Materials and Methods An institutional exemption from full ethical review was granted for the study. Five consultant radiologists were deemed the reference expert group, and four radiology registrars, five senior house officers (SHOs), and six interns formed four clinician groups. Participants were shown 30 chest radiographs, 14 of which had a pneumothorax, and were asked to give their level of confidence as to whether a pneumothorax was present. Receiver operating characteristic (ROC) curve analysis was carried out on diagnostic decisions. Eye movements were recorded with a Tobii TX300 (Tobii Technology, Stockholm, Sweden) eye tracker. Four eye-tracking metrics were analyzed. Variables were compared to identify any differences between groups. All data were compared by using the Friedman nonparametric method. Results The average area under the ROC curve for the groups increased with experience (0.947 for consultants, 0.792 for registrars, 0.693 for SHOs, and 0.659 for interns; P = .009). A significant difference in diagnostic accuracy was found between consultants and registrars (P = .046). All four eye-tracking metrics decreased with experience, and there were significant differences between registrars and SHOs. Total reading time decreased with experience; it was significantly lower for registrars compared with SHOs (P = .046) and for SHOs compared with interns (P = .025). Conclusion Chest radiograph interpretation skill increased with experience, both in terms of diagnostic accuracy and visual search. The observed level of experience at which there was a significant difference was higher for diagnostic accuracy than for eye-tracking metrics. (©) RSNA, 2016 Online supplemental material is available for this article.
Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M
2013-01-01
Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Blood samples were collected in the supine position from 1226 subjects, aged 5-84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results.
Eisenhofer, Graeme; Lattke, Peter; Herberg, Maria; Siegert, Gabriele; Qin, Nan; Därr, Roland; Hoyer, Jana; Villringer, Arno; Prejbisz, Aleksander; Januszewicz, Andrzej; Remaley, Alan; Martucci, Victoria; Pacak, Karel; Ross, H Alec; Sweep, Fred C G J; Lenders, Jacques W M
2016-01-01
Background Measurements of plasma normetanephrine and metanephrine provide a useful diagnostic test for phaeochromocytoma, but this depends on appropriate reference intervals. Upper cut-offs set too high compromise diagnostic sensitivity, whereas set too low, false-positives are a problem. This study aimed to establish optimal reference intervals for plasma normetanephrine and metanephrine. Methods Blood samples were collected in the supine position from 1226 subjects, aged 5–84 y, including 116 children, 575 normotensive and hypertensive adults and 535 patients in whom phaeochromocytoma was ruled out. Reference intervals were examined according to age and gender. Various models were examined to optimize upper cut-offs according to estimates of diagnostic sensitivity and specificity in a separate validation group of 3888 patients tested for phaeochromocytoma, including 558 with confirmed disease. Results Plasma metanephrine, but not normetanephrine, was higher (P < 0.001) in men than in women, but reference intervals did not differ. Age showed a positive relationship (P < 0.0001) with plasma normetanephrine and a weaker relationship (P = 0.021) with metanephrine. Upper cut-offs of reference intervals for normetanephrine increased from 0.47 nmol/L in children to 1.05 nmol/L in subjects over 60 y. A curvilinear model for age-adjusted compared with fixed upper cut-offs for normetanephrine, together with a higher cut-off for metanephrine (0.45 versus 0.32 nmol/L), resulted in a substantial gain in diagnostic specificity from 88.3% to 96.0% with minimal loss in diagnostic sensitivity from 93.9% to 93.6%. Conclusions These data establish age-adjusted cut-offs of reference intervals for plasma normetanephrine and optimized cut-offs for metanephrine useful for minimizing false-positive results. PMID:23065528
[Diagnostic kits in parasitology: which controls?].
Rossi, P
2004-06-01
The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic diseases are not available at present, except for Toxoplasma antibodies. The first international standard reagent for Anti-Toxoplasma Serum was established in 1968 and at present, an international standard reference serum, Anti-toxoplasma serum, human TOXM is available at the National Institute for Biological Standards and Control (NIBSC) in UK. Several collaborative, multicenter studies were carried out to assess the performance of different methods and commercial tests for the diagnosis of toxoplasmosis, by providing to participating laboratories a panel of well-defined sera to be tested. A four-phase process following well-accepted methodological standards for the development of diagnostics, analogous to those internationally accepted for drugs and vaccines was recently proposed. The pre-clinical evaluation, the analytic study to assess sensitivity, specificity, predictive values in laboratory (phase I), should be followed by a proof of principle study to distinguish diseased from healthy persons in easily accessible populations (phase II). The evaluation of test performance in populations of intended use (phase III), and finally the delineation of cost-effectiveness and societal impact of new tests in comparison with existing tools (phase IV) should complete the validation procedure. In this context, national regulatory agencies play a major role in pre-market approval and post-market surveillance of IVDs. The European Community in 1998 approved a directive (Directive 98/79/EC) which rules the marketing of IVD medical devices, in order to harmonise the performance levels and standards in European countries. But, among IVDs for parasitic diseases, only those to detect congenital toxoplasmosis are submitted to defined procedures to provide the verification of products before their placing on the market and the surveillance after their marketing by a notified body, which perform appropriate examinations, tests and inspections to production facilities to verify if the device meets the requirements of the directive. In U.S.A., the Food and Drug Administration (FDA), through the Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD), provides a comprehensive and regulatory activity for IVDs through pre-market evaluation and post-market surveillance. In developing countries, the scarcity of resources limits the procedures through which the national control authority can assure safety, quality and efficacy of products marketed, both imported and locally manufactured.
Tulsiani, S M; Craig, S B; Graham, G C; Cobbold, R C; Dohnt, M F; Burns, M-A; Jansen, C C; Leung, L K-P; Field, H E; Smythe, L D
2010-07-01
High-resolution melt-curve analysis of random amplified polymorphic DNA (RAPD-HRM) is a novel technology that has emerged as a possible method to characterise leptospires to serovar level. RAPD-HRM has recently been used to measure intra-serovar convergence between strains of the same serovar as well as inter-serovar divergence between strains of different serovars. The results indicate that intra-serovar heterogeneity and inter-serovar homogeneity may limit the application of RAPD-HRM in routine diagnostics. They also indicate that genetic attenuation of aged, high-passage-number isolates could undermine the use of RAPD-HRM or any other molecular technology. Such genetic attenuation may account for a general decrease seen in titres of rabbit hyperimmune antibodies over time. Before RAPD-HRM can be further advanced as a routine diagnostic tool, strains more representative of the wild-type serovars of a given region need to be identified. Further, RAPD-HRM analysis of reference strains indicates that the routine renewal of reference collections, with new isolates, may be needed to maintain the genetic integrity of the collections.
Bovine paratuberculosis: a review of the advantages and disadvantages of different diagnostic tests.
Gilardoni, Liliana R; Paolicchi, Fernando A; Mundo, Silvia L
2012-01-01
Paratuberculosis (PTB), or Johne's disease, is a chronic infectious granulomatous enteritis of ruminants, caused by Mycobacterium avium subspecies paratuberculosis (Map). It is characterized by diarrhea and progressive cachexia, which may cause the death of the animal. Calves are the most susceptible to infection. Infected animals excrete Map mainly by the feces. PTB is endemic worldwide, with high prevalence levels, strong economic impact and public health relevance because of its possible association with Crohn's disease. Although the current reference diagnostic test is identification of Map in the bacterial culture, there are different diagnostic tests to identify infected individuals and/or herds. The sensitivity and specificity of these tests vary according to the stage of the disease in the animals to be evaluated. The correct choice and application of each of these diagnostic tests will ensure their success and may allow to establish a control program. The aim of this work is to review and discuss the different diagnostic tests used in the detection of Map-infected animals, focusing on their advantages and disadvantages.
Fernandez, Ritin S; Chau, Janita Pak-Chun; Thompson, David R; Griffiths, Rhonda; Lo, Hoi-Shan
2010-08-01
The objective of this study was to investigate the diagnostic performance of biochemical tests used to determine placement of nasogastric (NG) tubes after insertion in adults. A systematic review of diagnostic studies was undertaken. A literature search of the bibliographic databases and the World Wide Web was performed to locate original diagnostic studies in English or Chinese on biochemical markers for detecting NG tube location. Studies in which one or more different tests were evaluated with a reference standard, and diagnostic values were reported or could be calculated were included. Two reviewers independently checked all abstracts and full text studies for inclusion criteria. Included studies were assessed for their quality using the QUADAS tool. Study features and diagnostic values were extracted from the included studies. Of the 10 studies included in this review, seven investigated the diagnostic accuracy of pH, one investigated the diagnostic accuracy of pH and bilirubin respectively, two a combination of pH and bilirubin and one a combination of pH, pepsin and trypsin levels in identifying NG tube location. All studies used X-rays as the reference standard for comparison. Pooled results demonstrated that a pH of
Lipid Panel Reference Intervals for Amazon Parrots (Amazona species).
Ravich, Michelle; Cray, Carolyn; Hess, Laurie; Arheart, Kristopher L
2014-09-01
The lipoprotein panel is a useful diagnostic tool that allows clinicians to evaluate blood lipoprotein fractions. It is a standard diagnostic test in human medicine but is poorly understood in avian medicine. Amazon parrots (Amazona species) are popular pets that frequently lead a sedentary lifestyle and are customarily fed high-fat diets. Similar to people with comparable diets and lifestyles, Amazon parrots are prone to obesity and atherosclerosis. In human medicine, these conditions are typically correlated with abnormalities in the lipoprotein panel. To establish reference intervals for the lipoprotein panel in Amazon parrots, plasma samples from 31 captive Amazon parrots were analyzed for concentrations of cholesterol, triglycerides, high-density lipoprotein (HDL), low-density lipoprotein (LDL), and very low-density lipoprotein (VLDL). The data were also grouped according to sex, diet, body condition score, and age. Aside from HDL levels, which were significantly different between male and female parrots, no intergroup differences were found for any of the lipoprotein fractions.
Pawlik, Marie-Christin; Kemp, Alison; Maguire, Sabine; Nuttall, Diane; Feldman, Kenneth W; Lindberg, Daniel M
2016-05-01
Intentional burns represent a serious form of physical abuse that must be identified to protect children from further harm. This study is a retrospectively planned secondary analysis of the Examining Siblings To Recognize Abuse (ExSTRA) network data. Our objective was to describe the characteristics of burns injuries in children referred to Child Abuse Pediatricians (CAPs) in relation to the perceived likelihood of abuse. We furthermore compare the extent of diagnostic investigations undertaken in children referred to CAPs for burn injuries with those referred for other reasons. Within this dataset, 7% (215/2890) of children had burns. Children with burns were older than children with other injuries (median age 20 months vs. 10 months). Physical abuse was perceived as likely in 40.9% (88) and unlikely in 59.1% (127). Scalds accounted for 52.6% (113) and contact burns for 27.6% (60). Several characteristics of the history and burn injury were associated with a significantly higher perceived likelihood of abuse, including children with reported inflicted injury, absent or inadequate explanation, hot water as agent, immersion scald, a bilateral/symmetric burn pattern, total body surface area ≥10%, full thickness burns, and co-existent injuries. The rates of diagnostic testing were significantly lower in children with burns than other injuries, yet the yield of skeletal survey and hepatic transaminases testing were comparable between the two groups. This would imply that children referred to CAPs for burns warrant the same level of comprehensive investigations as those referred for other reasons. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Should cognitive impairment be included in the diagnostic criteria for schizophrenia?
Keefe, Richard S E
2008-02-01
Neurocognitive impairment is considered a core component of schizophrenia, and is increasingly under investigation as a potential treatment target. On average, cognitive impairment is severe to moderately severe compared to healthy controls, and almost all patients with schizophrenia demonstrate cognitive decrements compared to their expected level if they had not developed the illness. Compared to patients with affective disorders, cognitive impairment in schizophrenia appears earlier, is more severe, and is more independent of clinical symptoms. Although the DSM-IV-TR and ICD-10 descriptions of schizophrenia include several references to cognitive impairment, neither the diagnostic criteria nor the subtypology of schizophrenia include a requirement of cognitive impairment. This paper forwards for consideration a proposal that the diagnostic criteria include a specific criterion of "a level of cognitive functioning suggesting a consistent severe impairment and/or a significant decline from premorbid levels considering the patient's educational, familial, and socioeconomic background". The inclusion of this criterion may increase the "point of rarity" with affective psychoses and may increase clinicians' awareness of cognitive impairment, potentially leading to more accurate prognosis, better treatment outcomes, and a clearer diagnostic signal for genetic and biological studies. Future research will need to address the validity of these possibilities. The reliable determination of cognitive impairment as part of a standard diagnostic evaluation will present challenges to diagnosticians with limited resources or insufficient expertise. Cognitive assessment methods for clinicians, including brief assessments and interview-based assessments, are discussed. Given the current emphasis on the development of cognitive treatments, the evaluation of cognition in schizophrenia is an essential component of mental health education.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, H; Wang, Y; Weng, H
Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the localmore » diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.« less
Ruiz-Cruces, R; Vano, E; Carrera-Magariño, F; Moreno-Rodriguez, F; Soler-Cantos, M M; Canis-Lopez, M; Hernández-Armas, J; Diaz-Romero, F J; Rosales-Espizua, F; Fernandez-Soto, J M; Sanchez-Casanueva, R; Martin-Palanca, A; Perez-Martinez, M; Gil-Agudo, A; Zarca-Diaz, M A; Parra-Osorio, V; Muñoz Ruiz-Canela, J J; Moreno-Sanchez, T; Lopez-Medina, A; Moreno-Saiz, C; Galan-Montenegro, P; Gallego-Beuter, J J; Gonzalez-de-Garay, M; Zapata-Jimenez, J C; Pastor-Vega, J M; Cañete, S
2016-12-01
To propose national diagnostic reference levels (DRLs) for interventional radiology and to evaluate the impact of the procedural complexity on patient doses. Eight interventional radiology units from Spanish hospitals were involved in this project. The participants agreed to undergo common quality control procedures for X-ray systems. Kerma area product (KAP) was collected from a sample of 1,649 procedures. A consensus document established the criteria to evaluate the complexity of seven types of procedures. DRLs were set as the 3rd quartile of KAP values. The KAP (3rd quartile) in Gy cm 2 for the procedures included in the survey were: lower extremity arteriography (n = 784) 78; renal arteriography (n = 37) 107; transjugular hepatic biopsies (THB) (n = 30) 45; biliary drainage (BD) (n = 314) 30; uterine fibroid embolization (UFE) (n = 56) 214; colon endoprostheses (CE) (n = 31) 169; hepatic chemoembolization (HC) (n = 269) 303; femoropopliteal revascularization (FR) (n = 62) 119; and iliac stent (n = 66) 170. The complexity involved the increases in the following KAP factors from simple to complex procedures: THB x4; BD x13; UFE x3; CE x3; HC x5; FR x5 and IS x4. The evaluation of the procedure complexity in patient doses will allow the proper use of DRLs for the optimization of interventional radiology. • National DRLs for interventional procedures have been proposed given level of complexity • For clinical audits, the level of complexity should be taken into account. • An evaluation of the complexity levels of the procedure should be made.
Cotten, Steven W; Shajani-Yi, Zahra; Cervinski, Mark A; Voorhees, Timothy; Tuchman, Sascha A; Korpi-Steiner, Nichole
2018-06-06
Serum free light chain (FLC) immunoglobulins are key biomarkers that aid in the diagnosis, prognosis and assessment of treatment response in patients with plasma cell disorders (PCD). Here we investigated the transference of manufacturer's reported κFLC, λFLC and κ to λ FLC reference intervals (RI) and established de novo FLC RI and diagnostic ranges on four instruments at three academic medical centers. In addition, we also compared the classification of patient FLC results using manufacturer's versus established RIs and diagnostic ranges. CLSI EP28-A3C protocol was applied to investigate transference and establishment of FLC reference intervals on the cobas (Roche), Immage (Beckman), Optilite and SPA Plus (Binding Site). Serum κ FLC and λ FLC were measured in reference sera (N = 126) with estimation of central 95% RIs and FLC ratio diagnostic range (total range). Frequencies (%) in patient FLC results (N > 380 per institution) classified above, below or within manufacturer's versus established FLC RI were compared. Three of four instrument platforms did not exhibit acceptable transference of manufacturer's reported κFLC RI. The manufacturer's reported FLC total diagnostic range did not encompass all values observed in reference sera for any of the four platforms evaluated. Established FLC ratio diagnostic ranges reduced the frequency of patient results classified above range for three of four platforms evaluated. Transference of manufacturer's reported FLC RIs may be inappropriate for select instrument platforms. De novo establishment of FLC RIs specific to instrument platform is highly recommended in order to assure correct patient result classification. Copyright © 2017. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Vacas-Jacques, Paulino; Linnes, Jacqueline; Young, Anna; Gerrard, Victoria; Gomez-Marquez, Jose
2014-03-01
Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second, the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vacas-Jacques, Paulino; Wellman Center for Photomedicine and Harvard Medical School, Massachusetts General Hospital, Boston, Massachusetts 02114; Linnes, Jacqueline
Innovations in international health require the use of state-of-the-art technology to enable clinical chemistry for diagnostics of bodily fluids. We propose the implementation of a portable and affordable lock-in amplifier-based instrument that employs digital technology to perform biochemical diagnostics on blood, urine, and other fluids. The digital instrument is composed of light source and optoelectronic sensor, lock-in detection electronics, microcontroller unit, and user interface components working with either power supply or batteries. The instrument performs lock-in detection provided that three conditions are met. First, the optoelectronic signal of interest needs be encoded in the envelope of an amplitude-modulated waveform. Second,more » the reference signal required in the demodulation channel has to be frequency and phase locked with respect to the optoelectronic carrier signal. Third, the reference signal should be conditioned appropriately. We present three approaches to condition the signal appropriately: high-pass filtering the reference signal, precise offset tuning the reference level by low-pass filtering, and by using a voltage divider network. We assess the performance of the lock-in instrument by comparing it to a benchmark device and by determining protein concentration with single-color absorption measurements. We validate the concentration values obtained with the proposed instrument using chemical concentration measurements. Finally, we demonstrate that accurate retrieval of phase information can be achieved by using the same instrument.« less
An audit of request forms submitted in a multidisciplinary diagnostic center in Lagos.
Oyedeji, Olufemi Abiola; Ogbenna, Abiola Ann; Iwuala, Sandra Omozehio
2015-01-01
Request forms are important means of communication between physicians and diagnostic service providers. Pre-analytical errors account for over two thirds of errors encountered in diagnostic service provision. The importance of adequate completion of request forms is usually underestimated by physicians which may result in medical errors or delay in instituting appropriate treatment. The aim of this study was to audit the level of completion of request forms presented at a multidisciplinary diagnostic center. A review of all requests forms for investigations which included radiologic, laboratory and cardiac investigations received between July and December 2011 was performed to assess their level of completeness. The data was entered into a spreadsheet and analyzed. Only 1.3% of the 7,841 request forms reviewed were fully completed. Patient's names, the referring physician's name and gender were the most completed information on the forms evaluated with 99.0%, 99.0% and 90.3% completion respectively. Patient's age was provided in 68.0%, request date in 88.2%, and clinical notes/ diagnosis in 65.9% of the requests. Patient's full address was provided in only 5.6% of requests evaluated. This study shows that investigation request forms are inadequately filled by physicians in our environment. Continuous medical education of physicians on the need for adequate completion of request forms is needed.
Diagnostic reference levels in low- and middle-income countries: early "ALARAm" bells?
Meyer, Steven; Groenewald, Willem A; Pitcher, Richard D
2017-04-01
Background In 1996 the International Commission on Radiological Protection (ICRP) introduced diagnostic reference levels (DRLs) as a quality assurance tool for radiation dose optimization. While many countries have published DRLs, available data are largely from high-income countries. There is arguably a greater need for DRLs in low- and middle-income-countries (LMICs), where imaging equipment may be older and trained imaging technicians are scarce. To date, there has been no critical analysis of the published work on DRLs in LMICs. Such work is important to evaluate data deficiencies and stimulate future quality assurance initiatives. Purpose To review the published work on DRLs in LMICs and to critically analyze the comprehensiveness of available data. Material and Methods Medline, Scopus, and Web of Science database searches were conducted for English-language articles published between 1996 and 2015 documenting DRLs for diagnostic imaging in LMICs. Retrieved articles were analyzed and classified by geographical region, country of origin, contributing author, year of publication, imaging modality, body part, and patient age. Results Fifty-three articles reported DRLs for 28 of 135 LMICs (21%), reflecting data from 26/104 (25%) middle-income countries and 2/31 (6%) low-income countries. General radiography (n = 26, 49%) and computerized tomography (n = 17, 32%) data were most commonly reported. Pediatric DRLs (n = 14, 26%) constituted approximately one-quarter of published work. Conclusion Published DRL data are deficient in the majority of LMICs, with the paucity most striking in low-income countries. DRL initiatives are required in LMICs to enhance dose optimization.
The mandate and work of ICRP Committee 3 on radiological protection in medicine.
Miller, D L; Martin, C J; Rehani, M M
2018-01-01
The mandate of Committee 3 of the International Commission on Radiological Protection (ICRP) is concerned with the protection of persons and unborn children when ionising radiation is used in medical diagnosis, therapy, and biomedical research. Protection in veterinary medicine has been newly added to the mandate. Committee 3 develops recommendations and guidance in these areas. The most recent documents published by ICRP that relate to radiological protection in medicine are 'Radiological protection in cone beam computed tomography' (ICRP Publication 129) and 'Radiological protection in ion beam radiotherapy' (ICRP Publication 127). A report in cooperation with ICRP Committee 2 entitled 'Radiation dose to patients from radiopharmaceuticals: a compendium of current information related to frequently used substances' (ICRP Publication 128) has also been published. 'Diagnostic reference levels in medical imaging' (ICRP Publication 135), published in 2017, provides specific advice on the setting and use of diagnostic reference levels for diagnostic and interventional radiology, digital imaging, computed tomography, nuclear medicine, paediatrics, and multi-modality procedures. 'Occupational radiological protection in interventional procedures' was published in March 2018 as ICRP Publication 139. A document on radiological protection in therapy with radiopharmaceuticals is likely to be published in 2018. Work is in progress on several other topics, including appropriate use of effective dose in collaboration with the other ICRP committees, guidance for occupational radiological protection in brachytherapy, justification in medical imaging, and radiation doses to patients from radiopharmaceuticals (an update to ICRP Publication 128). Committee 3 is also considering the development of guidance on radiological protection in medicine related to individual radiosusceptibility, in collaboration with ICRP Committee 1.
Factors influencing the probability of a diagnosis of autism spectrum disorder in girls versus boys.
Duvekot, Jorieke; van der Ende, Jan; Verhulst, Frank C; Slappendel, Geerte; van Daalen, Emma; Maras, Athanasios; Greaves-Lord, Kirstin
2017-08-01
In order to shed more light on why referred girls are less likely to be diagnosed with autism spectrum disorder than boys, this study examined whether behavioral characteristics influence the probability of an autism spectrum disorder diagnosis differently in girls versus boys derived from a multicenter sample of consecutively referred children aged 2.5-10 years. Based on information from the short version of the Developmental, Dimensional and Diagnostic Interview and the Autism Diagnostic Observation Schedule, 130 children (106 boys and 24 girls) received a diagnosis of autism spectrum disorder according to Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.) criteria and 101 children (61 boys and 40 girls) did not. Higher overall levels of parent-reported repetitive and restricted behavior symptoms were less predictive of an autism spectrum disorder diagnosis in girls than in boys (odds ratio interaction = 0.41, 95% confidence interval = 0.18-0.92, p = 0.03). In contrast, higher overall levels of parent-reported emotional and behavioral problems increased the probability of an autism spectrum disorder diagnosis more in girls than in boys (odds ratio interaction = 2.44, 95% confidence interval = 1.13-5.29, p = 0.02). No differences were found between girls and boys in the prediction of an autism spectrum disorder diagnosis by overall autistic impairment, sensory symptoms, and cognitive functioning. These findings provide insight into possible explanations for the assumed underidentification of autism spectrum disorder in girls in the clinic.
2010-01-01
Background Acute urinary tract infections (UTI) are one of the most common bacterial infections among women presenting to primary care. However, there is a lack of consensus regarding the optimal reference standard threshold for diagnosing UTI. The objective of this systematic review is to determine the diagnostic accuracy of symptoms and signs in women presenting with suspected UTI, across three different reference standards (102 or 103 or 105 CFU/ml). We also examine the diagnostic value of individual symptoms and signs combined with dipstick test results in terms of clinical decision making. Methods Searches were performed through PubMed (1966 to April 2010), EMBASE (1973 to April 2010), Cochrane library (1973 to April 2010), Google scholar and reference checking. Studies that assessed the diagnostic accuracy of symptoms and signs of an uncomplicated UTI using a urine culture from a clean-catch or catherised urine specimen as the reference standard, with a reference standard of at least ≥ 102 CFU/ml were included. Synthesised data from a high quality systematic review were used regarding dipstick results. Studies were combined using a bivariate random effects model. Results Sixteen studies incorporating 3,711 patients are included. The weighted prior probability of UTI varies across diagnostic threshold, 65.1% at ≥ 102 CFU/ml; 55.4% at ≥ 103 CFU/ml and 44.8% at ≥ 102 CFU/ml ≥ 105 CFU/ml. Six symptoms are identified as useful diagnostic symptoms when a threshold of ≥ 102 CFU/ml is the reference standard. Presence of dysuria (+LR 1.30 95% CI 1.20-1.41), frequency (+LR 1.10 95% CI 1.04-1.16), hematuria (+LR 1.72 95%CI 1.30-2.27), nocturia (+LR 1.30 95% CI 1.08-1.56) and urgency (+LR 1.22 95% CI 1.11-1.34) all increase the probability of UTI. The presence of vaginal discharge (+LR 0.65 95% CI 0.51-0.83) decreases the probability of UTI. Presence of hematuria has the highest diagnostic utility, raising the post-test probability of UTI to 75.8% at ≥ 102 CFU/ml and 67.4% at ≥ 103 CFU/ml. Probability of UTI increases to 93.3% and 90.1% at ≥ 102 CFU/ml and ≥ 103 CFU/ml respectively when presence of hematuria is combined with a positive dipstick result for nitrites. Subgroup analysis shows improved diagnostic accuracy using lower reference standards ≥ 102 CFU/ml and ≥ 103 CFU/ml. Conclusions Individual symptoms and signs have a modest ability to raise the pretest-risk of UTI. Diagnostic accuracy improves considerably when combined with dipstick tests particularly tests for nitrites. PMID:20969801
Giesen, Leonie G M; Cousins, Gráinne; Dimitrov, Borislav D; van de Laar, Floris A; Fahey, Tom
2010-10-24
Acute urinary tract infections (UTI) are one of the most common bacterial infections among women presenting to primary care. However, there is a lack of consensus regarding the optimal reference standard threshold for diagnosing UTI. The objective of this systematic review is to determine the diagnostic accuracy of symptoms and signs in women presenting with suspected UTI, across three different reference standards (10(2) or 10(3) or 10(5) CFU/ml). We also examine the diagnostic value of individual symptoms and signs combined with dipstick test results in terms of clinical decision making. Searches were performed through PubMed (1966 to April 2010), EMBASE (1973 to April 2010), Cochrane library (1973 to April 2010), Google scholar and reference checking.Studies that assessed the diagnostic accuracy of symptoms and signs of an uncomplicated UTI using a urine culture from a clean-catch or catherised urine specimen as the reference standard, with a reference standard of at least ≥ 10(2) CFU/ml were included. Synthesised data from a high quality systematic review were used regarding dipstick results. Studies were combined using a bivariate random effects model. Sixteen studies incorporating 3,711 patients are included. The weighted prior probability of UTI varies across diagnostic threshold, 65.1% at ≥ 10(2) CFU/ml; 55.4% at ≥ 10(3) CFU/ml and 44.8% at ≥ 10(2) CFU/ml ≥ 10(5) CFU/ml. Six symptoms are identified as useful diagnostic symptoms when a threshold of ≥ 10(2) CFU/ml is the reference standard. Presence of dysuria (+LR 1.30 95% CI 1.20-1.41), frequency (+LR 1.10 95% CI 1.04-1.16), hematuria (+LR 1.72 95%CI 1.30-2.27), nocturia (+LR 1.30 95% CI 1.08-1.56) and urgency (+LR 1.22 95% CI 1.11-1.34) all increase the probability of UTI. The presence of vaginal discharge (+LR 0.65 95% CI 0.51-0.83) decreases the probability of UTI. Presence of hematuria has the highest diagnostic utility, raising the post-test probability of UTI to 75.8% at ≥ 10(2) CFU/ml and 67.4% at ≥ 10(3) CFU/ml. Probability of UTI increases to 93.3% and 90.1% at ≥ 10(2) CFU/ml and ≥ 10(3) CFU/ml respectively when presence of hematuria is combined with a positive dipstick result for nitrites. Subgroup analysis shows improved diagnostic accuracy using lower reference standards ≥ 10(2) CFU/ml and ≥ 10(3) CFU/ml. Individual symptoms and signs have a modest ability to raise the pretest-risk of UTI. Diagnostic accuracy improves considerably when combined with dipstick tests particularly tests for nitrites.
Biochemical tests cannot differentiate between tonsillar and middle ear-derived infections.
Christensen, Ann Marlene Gram; Kirkegaard, Martin Glymer; Randrup, Thomas Skov; Klug, Tejs Ehlers
2013-05-01
Infection markers are appreciated supplements in the clinical diagnosis of ear, nose and throat (ENT) infections. We aimed to examine the differential diagnostic usefulness of C-reactive protein (CRP), white blood cell count (WBC) and absolute neutrophil count (ANC) according to severity of middle ear and tonsillar infections. This was a retrospective study including all patients admitted to the ENT Department, Aarhus University Hospital, from January 2001 to December 2008 and diagnosed with acute otitis media, mastoidismus, acute mastoiditis, acute tonsillitis, peritonsillar abscess, parapharyngeal abscess and necrotizing fasciitis. A total of 1,773 patients were included. Between the tonsil subgroups, significant differences were found in CRP (p < 0.001), WBC (p < 0.001) and ANC (p < 0.001) levels. However, sensitivities and specificities related to differential diagnostics were low. In the middle ear group, no differences in CRP (p = 0.84), WBC (p = 0.46), and ANC (p = 0.72) levels were found. The number of CRP levels above the reference value was significantly higher than the corresponding number of WBC and ANC levels. A trend (non-significant) was found towards lower parameter levels in acute tonsillitis and peritonsillar abscess patients who grew Staphylococcus aureus compared with patients infected with other bacteria. CRP and ANC levels were related to severity of tonsillar-derived infections, but no such relation was found in infections with middle ear origin. None of the infection markers studied were useful for differential diagnostics. not relevant. not relevant.
Schmidt-Hieltjes, Yvonne; Elshof, Clemens; Roovers, Lian; Ruinemans-Koerts, Janneke
2016-05-01
The aim of our study was to analyse whether the κ/λ free light chain ratio reference range for screening for Bence Jones proteinuria should be dependent on the estimated glomerular filtration rate (eGFR). The serum κ/λ free light chain ratio, eGFR, serum M-protein and Bence Jones protein were measured in 544 patients for whom Bence Jones protein analysis was ordered. In the population of patients without Bence Jones proteinuria or a M-protein (n = 402), there is no gradual increase in κ/λ free light chain ratio with diminishing eGFR. The κ/λ free light chain ratio in this group was 0.56-1.86 (95% interval). With this diagnostic reference range of the κ/λ ratio, 105 of the 110 patients with Bence Jones protein could be identified correctly. Only five patients with Bence Jones proteinuria (<0.17 g/L) were missed, without diagnostic or therapeutic consequences. In 36 patients (6.6%), an abnormal κ/λ free light chain ratio was measured without the presence of Bence Jones proteinuria. A κ/λ free light chain ratio in serum can be used safely and efficiently to select urine samples which should be analysed for Bence Jones proteinuria with an electrophoresis/immunofixation technique. Using this diagnostic reference range, the number of urine samples which should be analysed by electrophoresis/immunofixation could be reduced by 74%. The diagnostic reference interval can be determined best in a group of patients for whom Bence Jones analysis is indicated. For calculation of this reference range, the eGFR value does not need to be taken into account. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Veres, Gábor; Szpisjak, László; Bajtai, Attila; Siska, Andrea; Klivényi, Péter; Ilisz, István; Földesi, Imre; Vécsei, László; Zádori, Dénes
2017-09-01
Evidence suggests that decreased α-tocopherol (the most biologically active substance in the vitamin E group) level can cause neurological symptoms, most likely ataxia. The aim of the current study was to first provide reference intervals for serum tocopherols in the adult Hungarian population with appropriate sample size, recruiting healthy control subjects and neurological patients suffering from conditions without symptoms of ataxia, myopathy or cognitive deficiency. A validated HPLC method applying a diode array detector and rac-tocol as internal standard was utilized for that purpose. Furthermore, serum cholesterol levels were determined as well for data normalization. The calculated 2.5-97.5% reference intervals for α-, β/γ- and δ-tocopherols were 24.62-54.67, 0.81-3.69 and 0.29-1.07 μm, respectively, whereas the tocopherol/cholesterol ratios were 5.11-11.27, 0.14-0.72 and 0.06-0.22 μmol/mmol, respectively. The establishment of these reference intervals may improve the diagnostic accuracy of tocopherol measurements in certain neurological conditions with decreased tocopherol levels. Moreover, the current study draws special attention to the possible pitfalls in the complex process of the determination of reference intervals as well, including the selection of study population, the application of internal standard and method validation and the calculation of tocopherol/cholesterol ratios. Copyright © 2017 John Wiley & Sons, Ltd.
An evaluation of consensus techniques for diagnostic interpretation
NASA Astrophysics Data System (ADS)
Sauter, Jake N.; LaBarre, Victoria M.; Furst, Jacob D.; Raicu, Daniela S.
2018-02-01
Learning diagnostic labels from image content has been the standard in computer-aided diagnosis. Most computer-aided diagnosis systems use low-level image features extracted directly from image content to train and test machine learning classifiers for diagnostic label prediction. When the ground truth for the diagnostic labels is not available, reference truth is generated from the experts diagnostic interpretations of the image/region of interest. More specifically, when the label is uncertain, e.g. when multiple experts label an image and their interpretations are different, techniques to handle the label variability are necessary. In this paper, we compare three consensus techniques that are typically used to encode the variability in the experts labeling of the medical data: mean, median and mode, and their effects on simple classifiers that can handle deterministic labels (decision trees) and probabilistic vectors of labels (belief decision trees). Given that the NIH/NCI Lung Image Database Consortium (LIDC) data provides interpretations for lung nodules by up to four radiologists, we leverage the LIDC data to evaluate and compare these consensus approaches when creating computer-aided diagnosis systems for lung nodules. First, low-level image features of nodules are extracted and paired with their radiologists semantic ratings (1= most likely benign, , 5 = most likely malignant); second, machine learning multi-class classifiers that handle deterministic labels (decision trees) and probabilistic vectors of labels (belief decision trees) are built to predict the lung nodules semantic ratings. We show that the mean-based consensus generates the most robust classi- fier overall when compared to the median- and mode-based consensus. Lastly, the results of this study show that, when building CAD systems with uncertain diagnostic interpretation, it is important to evaluate different strategies for encoding and predicting the diagnostic label.
Fosbøl, M; Reving, S; Petersen, E H; Rossing, P; Lajer, M; Zerahn, B
2017-01-01
To investigate whether inclusion of quantitative data on blood flow distribution compared with visual qualitative evaluation improve the reliability and diagnostic performance of 99 m Tc-hydroxymethylene diphosphate three-phase bone scintigraphy (TPBS) in patients suspected for charcot neuropathic osteoarthropathy (CNO) of the foot. A retrospective cohort study of TPBS performed on 148 patients with suspected acute CNO referred from a single specialized diabetes care centre. The quantitative blood flow distribution was calculated based on the method described by Deutsch et al. All scintigraphies were re-evaluated by independent, blinded observers twice with and without quantitative data on blood flow distribution at ankle and focus level, respectively. The diagnostic validity of TPBS was determined by subsequent review of clinical data and radiological examinations. A total of 90 patients (61%) had confirmed diagnosis of CNO. The sensitivity, specificity and accuracy of three-phase bone scintigraphy without/with quantitative data were 89%/88%, 58%/62% and 77%/78%, respectively. The intra-observer agreement improved significantly by adding quantitative data in the evaluation (Kappa value 0·79/0·94). The interobserver agreement was not significantly improved. Adding quantitative data on blood flow distribution in the interpretation of TBPS improves intra-observer variation, whereas no difference in interobserver variation was observed. The sensitivity of TPBS in the diagnosis of CNO is high, but holds limited specificity. Diagnostic performance does not improve using quantitative data in the evaluation. This may be due to the reference intervals applied in the study or the absence of a proper gold standard diagnostic procedure for comparison. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
International External Quality Assurance for Laboratory Diagnosis of Diphtheria ▿
Neal, S. E.; Efstratiou, A.
2009-01-01
The diphtheria surveillance network (DIPNET) encompassing National Diphtheria Reference Centers from 25 European countries is a Dedicated Surveillance Network recognized by the European Commission. A key DIPNET objective is the quality assessment of microbiological procedures for diphtheria across the European Union and beyond. A detailed questionnaire on the level of reference laboratory services and an external quality assessment (EQA) panel comprising six simulated throat specimens were sent to 34 centers. Twenty-three centers are designated National Diphtheria Reference Centers, with the laboratory in the United Kingdom being the only WHO Collaborating Centre. A variety of screening and identification tests were used, including the cysteinase test (20/34 centers), pyrazinamidase test (17/34 centers), and commercial kits (25/34 centers). The classic Elek test for toxigenicity testing is mostly used (28/34 centers), with variations in serum sources and antitoxin concentrations. Many laboratories reported problems obtaining Elek reagents or media. Only six centers produced acceptable results for all six specimens. Overall, 21% of identification and 13% of toxigenicity reports were unacceptable. Many centers could not isolate the target organism, and most found difficulties with the specimens that contained Corynebacterium striatum as a commensal contaminant. Nineteen centers generated either false-positive or negative toxigenic results, which may have caused inappropriate medical management. The discrepancies in this diphtheria diagnostics EQA alarmingly reflect the urgent need to improve laboratory performance in diphtheria diagnostics in Europe, standardize feasible and robust microbiological methods, and build awareness among public health authorities. Therefore, DIPNET recommends that regular workshops and EQA distributions for diphtheria diagnostics should be supported and maintained. PMID:19828749
İnal, Tolga; Ataç, Gökçe
2014-01-01
We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.
Kolecka, Anna; Khayhan, Kantarawee; Groenewald, Marizeth; Theelen, Bart; Arabatzis, Michael; Velegraki, Aristea; Kostrzewa, Markus; Mares, Mihai; Taj-Aldeen, Saad J.
2013-01-01
Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) was used for an extensive identification study of arthroconidial yeasts, using 85 reference strains from the CBS-KNAW yeast collection and 134 clinical isolates collected from medical centers in Qatar, Greece, and Romania. The test set included 72 strains of ascomycetous yeasts (Galactomyces, Geotrichum, Saprochaete, and Magnusiomyces spp.) and 147 strains of basidiomycetous yeasts (Trichosporon and Guehomyces spp.). With minimal preparation time, MALDI-TOF MS proved to be an excellent diagnostic tool that provided reliable identification of most (98%) of the tested strains to the species level, with good discriminatory power. The majority of strains were correctly identified at the species level with good scores (>2.0) and seven of the tested strains with log score values between 1.7 and 2.0. The MALDI-TOF MS results obtained were consistent with validated internal transcribed spacer (ITS) and/or large subunit (LSU) ribosomal DNA sequencing results. Expanding the mass spectrum database by increasing the number of reference strains for closely related species, including those of nonclinical origin, should enhance the usefulness of MALDI-TOF MS-based diagnostic analysis of these arthroconidial fungi in medical and other laboratories. PMID:23678074
Establishment of new complete blood count reference values for healthy Thai adults.
Wongkrajang, P; Chinswangwatanakul, W; Mokkhamakkun, C; Chuangsuwanich, N; Wesarachkitti, B; Thaowto, B; Laiwejpithaya, S; Komkhum, O
2018-04-28
Laboratory reference ranges are essential for diagnostic orientation and treatment decision. As complete blood count parameters are influenced by various factors, including gender, geographic origin, and ethnic origin, it is important to establish specific hematologic reference values for specific populations. This study was conducted at the Department of Clinical Pathology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand. Blood samples were taken from healthy adults aged 18-60 years that attended a health check-up program at our hospital during February 2015 to July 2015. Hematologic and routine chemistry analysis were performed. Participants were determined to be healthy based on medical history and routine medical examinations. Serum vitamin B12, folate, ferritin, and hemoglobin typing were also analyzed to exclude the possible presence of anemia. A statistically significant difference was observed between males and females for Hb level, hematocrit level, red blood cell count, mean corpuscular hemoglobin concentration, percentage neutrophils, monocytes and eosinophils, and absolute neutrophil, lymphocyte, basophil, and platelet counts. Accordingly, gender-specific reference intervals were established for all complete blood count parameters in healthy Thai adult population. The reference value ranges established in this study reflect significant differences between genders. It is possible that these reference ranges may be generalizable to adults living in Thailand. The findings of this study emphasize the importance of establishing specific hematologic reference values for specific populations. © 2018 John Wiley & Sons Ltd.
Sotillo-Díaz, J C; Bermejo-López, E; García-Olivares, P; Peral-Gutiérrez, J A; Sancho-González, M; Guerrero-Sanz, J E
2014-01-01
To determine the role of plasma procalcitonin (PCT) levels in diagnosing ventilator-associated pneumonia. A systematic review of publications prospectively assessing the diagnostic role of PCT in ventilator-associated pneumonia was carried out. The search was performed using Medline, Embase, the Cochrane Collaboration and MEDION, with reviewing of the references of retrieved articles. We extracted data that allowed the calculation of sensitivity, specificity, likelihood ratios and diagnostic odds ratio. Intervention Metaregression was performed to determine whether exposure to previous antibiotic treatment, the time to occurrence of ventilator-associated pneumonia and the type of patients had an impact upon the diagnostic performance of procalcitonin. Seven studies were considered (373 patients, 434 episodes). We found no publication bias or threshold effect. High plasma PCT levels were associated to an increased risk of suffering ventilator-associated pneumonia (OR: 8.39; 95% CI: 5.4-12.6). The pooled data on sensitivity, specificity, positive and negative likelihood ratio, and diagnostic odds ratio found were 76% (69-82), 79% (74-84), 4.35 (2.48-7.62), 0.26 (0.15-0.46) and 17.9 (10.1-31.7), respectively. Diagnostic yield was modified by prior exposure to antibiotics (rDOR 0.11, 0.02-0.069), but not by the type of critically ill patient or the time to occurrence of ventilator-associated pneumonia. Our results suggest that PCT provides additional information on the risk of VAP. Inclusion of PCT in diagnostic algorithms could improve their effectiveness. Copyright © 2013 Elsevier España, S.L. and SEMICYUC. All rights reserved.
A New Method with General Diagnostic Utility for the Calculation of Immunoglobulin G Avidity
Korhonen, Maria H.; Brunstein, John; Haario, Heikki; Katnikov, Alexei; Rescaldani, Roberto; Hedman, Klaus
1999-01-01
The reference method for immunoglobulin G (IgG) avidity determination includes reagent-consuming serum titration. Aiming at better IgG avidity diagnostics, we applied a logistic model for the reproduction of antibody titration curves. This method was tested with well-characterized serum panels for cytomegalovirus, Epstein-Barr virus, rubella virus, parvovirus B19, and Toxoplasma gondii. This approach for IgG avidity calculation is generally applicable and attains the diagnostic performance of the reference method while being less laborious and twice as cost-effective. PMID:10473525
Wimpole, Justin A; Adagra, Carl F M; Billson, Mark F; Pillai, Dilo N; Foster, Darren J
2010-06-01
Phaeochromocytomas are catecholamine-secreting tumours of the adrenal glands and are rare in cats. Plasma metanephrine levels are widely considered the diagnostic test of choice for phaeochromocytoma in people but have not been investigated in cats. In this study plasma free normetanephrine and metanephrine levels were measured using high-pressure liquid chromatography in healthy cats, sick cats with non-adrenal disease and in a cat with a suspected phaeochromocytoma. Plasma normetanephrine was significantly higher in sick cats with non-adrenal disease compared to healthy cats (P<0.05) and markedly higher in the cat with a suspected phaeochromocytoma when compared to either group. Plasma metanephrine was not significantly different in any of the groups. This study establishes a first-line guide reference range for plasma metanephrine and normetanephrine levels in healthy cats and cats with non-adrenal disease. These results provide rationale for further studies to establish the use of plasma normetanephrine levels as a potential diagnostic test for phaeochromocytoma in the cat. Copyright 2009 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Boot, Christopher; Toole, Barry; Johnson, Sarah J; Ball, Stephen; Neely, Dermot
2017-01-01
Background Measurement of plasma metanephrines is regarded as one of the best screening tests for phaeochromocytoma/paraganglioma. Current guidelines recommend that samples are ideally collected in the supine position after 30 min rest and interpreted using supine reference ranges, in order to optimize the diagnostic performance of the test. Current practice in our centre is to collect samples for plasma metanephrines from seated patients. The aim of the study was to determine, if seated sampling for plasma metanephrines provides acceptable diagnostic performance in our centre. Methods Clinical and laboratory data of 113 patients, gathered over a four-year period 2010-2014, were reviewed. All had undergone preoperative plasma metanephrines measurement and had postoperative histopathology confirmation or exclusion of phaeochromocytoma/paraganglioma. Results Of 113 patients included in the study, 40 had a histological diagnosis of phaeochromocytoma/paraganglioma. The remaining 73 patients had an alternative adrenal pathology. The diagnostic sensitivity of normetanephrine or metanephrine above the upper limit of our in-house seated reference range was 93%. However, excluding three cases of paraganglioma determined clinically and biochemically to be non-functional raised the sensitivity to 100%. Diagnostic specificity was 90%. Applying published supine reference ranges made no difference to diagnostic sensitivity in this group of patients but decreased diagnostic specificity to 75%. Conclusions While these data are derived from a relatively small study population, they demonstrate acceptable diagnostic performance for seated plasma metanephrines as a screening test for phaeochromocytoma/paraganglioma. These data highlight a high diagnostic sensitivity for plasma metanephrines with seated sampling in our centre.
Ariizumi, Takashi; Kawashima, Hiroyuki; Ogose, Akira; Sasaki, Taro; Hotta, Tetsuo; Hatano, Hiroshi; Morita, Tetsuro; Endo, Naoto
2018-01-01
The value of routine blood tests in malignant soft tissue tumors remains uncertain. To determine if these tests can be used for screening, the routine pretreatment blood test findings were retrospectively investigated in 359 patients with benign and malignant soft tissue tumors. Additionally, the prognostic potential of pretreatment blood abnormalities was evaluated in patients with soft tissue sarcomas. We compared clinical factors and blood tests findings between patients with benign and malignant soft tissue tumors using univariate and multivariate analysis. Subsequently, patients with malignant tumors were divided into two groups based on blood test reference values, and the prognostic significance of each parameter was evaluated. In the univariate analysis, age, tumor size, and tumor depth were significant clinical diagnostic factors. Significant increases in the granulocyte count, C-reactive protein (CRP) level, erythrocyte sedimentation rate (ESR), and γ-glutamyl transpeptidase (γ-GTP) levels were found in patients with malignant soft tissue tumors. Multiple logistic regression showed that tumor size and ESR were independent factors that predicted malignant soft tissue tumors. The Kaplan-Meier survival analysis revealed that granulocyte counts, γ-GTP levels, and CRP levels correlated significantly with overall survival. Thus, pretreatment routine blood tests are useful diagnostic and prognostic markers for diagnosing soft tissue sarcoma. © 2018 by the Association of Clinical Scientists, Inc.
Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming
2015-01-01
Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.
Warhurst, Geoffrey; Dunn, Graham; Chadwick, Paul; Blackwood, Bronagh; McAuley, Daniel; Perkins, Gavin D; McMullan, Ronan; Gates, Simon; Bentley, Andrew; Young, Duncan; Carlson, Gordon L; Dark, Paul
2015-05-01
There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. Critical care departments within NHS hospitals in the north-west of England. Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4-16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error. The systematic review is registered as PROSPERO CRD42011001289. The National Institute for Health Research Health Technology Assessment programme. Professor Daniel McAuley and Professor Gavin D Perkins contributed to the systematic review through their funded roles as codirectors of the Intensive Care Foundation (UK).
[Impaired renal function: be aware of exogenous factors].
van der Meijden, Wilbert A G; Smak Gregoor, Peter J H
2013-01-01
Renal function is currently estimated using the Modification of Diet in Renal Disease (MDRD) formula, which is partly based on the serum creatinine level. Patients with impaired renal function are referred to nephrologists in accordance with the Dutch national transmural agreement for 'Chronic renal impairment'. A 54-year-old woman without significant history was referred to analyse a coincidentally found decline in the estimated glomerular filtration rate (eGFR). The patient had no complaints and used no medication except creatine supplements. Additional diagnostic testing showed no abnormalities. After cessation of creatine supplementation, the calculated renal function normalized. Serum creatinine is a reflection of muscle mass. The use of creatine-containing dietary supplements, such as creatine ethyl ester, can influence serum creatinine levels and therefore the eGFR as calculated with the MDRD formula. The use of supplements deserves attention when taking the history.
Muzzarelli, Stefano; Ordovas, Karen Gomes; Hope, Michael D; Meadows, Jeffery J; Higgins, Charles B; Meadows, Alison Knauth
2011-06-01
To compare aortic flow profiles at the level of the proximal descending (PDAo) and distal descending aorta (DDAo) in patients investigated for coarctation of the aorta (CoA), and compare their respective diagnostic value for predicting severe CoA. Diastolic flow decay in the PDAo predicts severe CoA, but flow measurements at this level are limited by flow turbulence, aliasing, and stent-related artifacts. We studied 49 patients evaluated for CoA with phase contrast magnetic resonance imaging (PC-MRI). Parameters of diastolic flow decay in the PDAo and DDAo were compared. Their respective diagnostic value was compared with the standard reference of transcatheter peak gradient ≥20 mmHg. Flow measurement in the PDAo required repeated acquisition with adjustment of encoding velocity or location of the imaging plane in 69% of patients; measurement in the DDAo was achieved in single acquisition in all cases. Parameters of diastolic flow decay in the PDAo and DDAo, including rate-corrected (RC) deceleration time and RC flow deceleration yielded a good correlation (r = 0.78; P < 0.01, and r = 0.92; P < 0.01), and a similar diagnostic value for predicting severe CoA. The highest diagnostic accuracy was achieved by RC deceleration time at DDAo (sensitivity 85%, specificity 85%). Characterization of aortic flow profiles at the DDAo offers a quick and reliable noninvasive means of assessing hemodynamically significant CoA. Copyright © 2011 Wiley-Liss, Inc.
Diagnostic imaging for acute appendicitis: interfacility differences in practice patterns.
Michailidou, Maria; Sacco Casamassima, Maria G; Karim, Omar; Gause, Colin; Salazar, Jose H; Goldstein, Seth D; Abdullah, Fizan
2015-04-01
To evaluate trends and factors associated with interfacility differences in imaging modality selection in the diagnosis and management of children with suspected acute appendicitis. We conducted a retrospective review of diagnostic imaging selection and outcomes in patients <20 years of age who underwent appendectomy at a single Children's Hospital from June 2008 to June 2013. These results were then compared with those of referring hospitals. A total of 232 children underwent appendectomy during the study period. Imaging results contributed to diagnostic and management decisions in 95.3 % of cases. CT scan was utilized as first-line imaging in 50 % of cases. CTs were preferentially performed at referring institutions (78 vs. 46 %, p < 0.001). Children were five times more likely to undergo CT at referring institutions (OR = 5.5, CI 3.0-10.2). Adjusting for demographics and Alvarado score, diagnostic imaging choice was independent of patient's clinical status. This study demonstrates that initial presentation to a referring hospital independently predicts the use of CT scan for suspected acute appendicitis. Further efforts should be undertaken to develop a clinical pathway that minimizes radiation exposure in the diagnosis of acute appendicitis, with focus on access to pediatric abdominal ultrasound.
Laslett, Mark; Oberg, Birgitta; Aprill, Charles N; McDonald, Barry
2005-01-01
The "centralization phenomenon" (CP) is the progressive retreat of referred pain towards the spinal midline in response to repeated movement testing (a McKenzie evaluation). A previous study suggested that it may have utility in the clinical diagnosis of discogenic pain and may assist patient selection for discography and specific treatments for disc pain. Estimation of the diagnostic predictive power of centralization and the influence of disability and patient distress on diagnostic performance, using provocation discography as a criterion standard for diagnosis, in chronic low back pain patients. This study was a prospective, blinded, concurrent, reference standard-related validity design carried out in a private radiology clinic specializing in diagnosis of chronic spinal pain. Consecutive patients with persistent low back pain were referred to the study clinic by orthopedists and other medical specialists for interventional radiological diagnostic procedures. Patients were typically disabled and displayed high levels of psychosocial distress. The sample included patients with previous lumbar surgery, and most had unsuccessful conservative therapies previously. results of provocation discography. The CP. Psychometric evaluation: Roland-Morris, Zung, Modified Somatic Perception questionnaires, Distress Risk Assessment Method, and 100-mm visual analog scales for pain intensity. Patients received a single physical therapy examination, followed by lumbar provocation discography. Sensitivity, specificity, and likelihood ratios of the CP were estimated in the group as a whole and in subgroups defined by psychometric measures. A total of 107 patients received the clinical examination and discography at two or more levels and post-discography computed tomography. Thirty-eight could not tolerate a full physical examination and were excluded from the main analysis. Disability and pain intensity ratings were high, and distress was common. Sensitivity, specificity, and positive likelihood ratios for centralization observed during repeated movement testing for pain distribution and intensity changes were 40%, 94%, and 6.9 respectively. In the presence of severe disability, sensitivity, specificity, and positive likelihood ratios were 46%, 80%, 3.2 and for distress, 45%, 89%, 4.1. In the subgroups with moderate, minimal, or no disability, sensitivity and specificity were 37%, 100% and for no or minimal distress 35%, 100%. Centralization is highly specific to positive discography but specificity is reduced in the presence of severe disability or psychosocial distress.
HÖner, Oliver; Votteler, Andreas; Schmid, Markus; Schultz, Florian; Roth, Klaus
2015-01-01
The utilisation of motor performance tests for talent identification in youth sports is discussed intensively in talent research. This article examines the reliability, differential stability and validity of the motor diagnostics conducted nationwide by the German football talent identification and development programme and provides reference values for a standardised interpretation of the diagnostics results. Highly selected players (the top 4% of their age groups, U12-U15) took part in the diagnostics at 17 measurement points between spring 2004 and spring 2012 (N = 68,158). The heterogeneous test battery measured speed abilities and football-specific technical skills (sprint, agility, dribbling, ball control, shooting, juggling). For all measurement points, the overall score and the speed tests showed high internal consistency, high test-retest reliability and satisfying differential stability. The diagnostics demonstrated satisfying factorial-related validity with plausible and stable loadings on the two empirical factors "speed" and "technical skills". The score, and the technical skills dribbling and juggling, differentiated the most among players of different performance levels and thus showed the highest criterion-related validity. Satisfactory psychometric properties for the diagnostics are an important prerequisite for a scientifically sound rating of players' actual motor performance and for the future examination of the prognostic validity for success in adulthood.
Nabeta, Pamela; Havumaki, Joshua; Ha, Dang Thi Minh; Caceres, Tatiana; Hang, Pham Thu; Collantes, Jimena; Thi Ngoc Lan, Nguyen; Gotuzzo, Eduardo; Denkinger, Claudia M
2017-01-01
Improved and affordable diagnostic or triage tests are urgently needed at the microscopy centre level. Automated digital microscopy has the potential to overcome issues related to conventional microscopy, including training time requirement and inconsistencies in results interpretation. For this blinded prospective study, sputum samples were collected from adults with presumptive pulmonary tuberculosis in Lima, Peru and Ho Chi Minh City, Vietnam. TBDx performance was evaluated as a stand-alone and as a triage test against conventional microscopy and Xpert, with culture as the reference standard. Xpert was used to confirm positive cases. A total of 613 subjects were enrolled between October 2014 and March 2015, with 539 included in the final analysis. The sensitivity of TBDx was 62·2% (95% CI 56·6-67·4) and specificity was 90·7% (95% CI 85·9-94·2) compared to culture. The algorithm assessing TBDx as a triage test achieved a specificity of 100% while maintaining sensitivity. While the diagnostic performance of TBDx did not reach the levels obtained by experienced microscopists in reference laboratories, it is conceivable that it would exceed the performance of less experienced microscopists. In the absence of highly sensitive and specific molecular tests at the microscopy centre level, TBDx in a triage-testing algorithm would optimize specificity and limit overall cost without compromising the number of patients receiving up-front drug susceptibility testing for rifampicin. However, the algorithm would miss over one third of patients compared to Xpert alone.
Transcript and protein environmental biomarkers in fish--a review.
Tom, Moshe; Auslander, Meirav
2005-04-01
The levels of contaminant-affected gene products (transcripts and proteins) are increasingly utilized as environmental biomarkers, and their appropriate implementation as diagnostic tools is discussed. The required characteristics of a gene product biomarker are accurate evaluation using properly normalized absolute units, aiming at long-term comparability of biomarker levels over a wide geographical range and among many laboratories. Quantitative RT-PCR and competitive ELISA are suggested as preferred evaluation methods for transcript and protein, respectively. Constitutively expressed RNAs or proteins which are part of the examined homogenate are suggested as normalizing agents, compensating for variable processing efficiency. Essential characterization of expression patterns is suggested, providing reference values to be compared to the monitored levels. This comparison would enable estimation of the intensity of biological effects of contaminants. Contaminant-independent reference expression patterns should include natural fluctuations of the biomarker level. Contaminant-dependent patterns should include dose response to model contaminants chronically administered in two environmentally-realistic routes, reaching extreme sub-lethal affected levels. Recent studies using fish as environmental sentinel species, applying gene products as environmental biomarkers, and implementing at least part of the depicted methodologies are reviewed.
Schlenz, H; Intemann, T; Wolters, M; González-Gil, E M; Nappo, A; Fraterman, A; Veidebaum, T; Molnar, D; Tornaritis, M; Sioen, I; Mårild, S; Iacoviello, L; Ahrens, W
2014-09-01
C-reactive protein (CRP) is involved in a wide range of diseases. It is a powerful marker for inflammatory processes used for diagnostic and monitoring purposes. We aimed to establish reference values as data on the distribution of serum CRP levels in young European children are scarce. Reference values of high-sensitivity CRP concentrations were calculated for 9855 children aged 2.0-10.9 years, stratified by age and sex. The children were recruited during the population-based European IDEFICS study (Identification and prevention of Dietary- and lifestyle-induced health Effects in Children and infantS) with 18 745 participants recruited from 2007 to 2010. In 44.1% of the children, CRP values were below or equal the detection limit of 0.2 mg/l. Median CRP concentrations showed a slight negative age trend in boys and girls, whereas serum CRP values were slightly higher in girls than in boys across all age groups. Our population-based reference values of CRP may guide paediatric practice as elevated values may require further investigation or treatment. Therefore, the presented reference values represent a basis for clinical evaluation and for future research on risk assessment of diseases associated with increased CRP levels among children.
Leers, M P G; Keuren, J F W; Oosterhuis, W P
2010-12-01
In patients with inflammatory conditions, diagnosing classic iron deficiency or anemia of chronic disease is challenging. In this study, we assessed the diagnostic value of the so-called Thomas'-plot [soluble transferrin receptor (sTfR)/log ferritin (sTfr/log Ferr) and the reticulocyte hemoglobin equivalent (Ret-HE)] in the anemia work up of patients referred by general practitioners. During July 2008-March 2009, 337 consecutive patients were included because of lowered Hb values. The laboratory results of the first 133 consecutive patients were used to determine the cut-off values for the diagnostic plot. The laboratory results of these patients were assessed and interpreted independently by two investigators, blinded from sTfR/log Ferr and Ret-HE values. The following 204 patients were used to test the plot in practice. In 32% of the first 133 patients, no indication of the cause of anemia could be found. However, when using the diagnostic plot in the following 204 patients, this fraction decreased to 14%. The 'Thomas'-plot is of diagnostic value for distinguishing functional iron deficiency from classic iron deficiency in a patient population referred by general practitioners. © 2010 Blackwell Publishing Ltd.
Lowered reference limits for hCG improve follow-up of patients with hCG-producing tumors.
Nome, Ragnhild V; Bjøro, Trine; Paus, Elisabeth; Bjerner, Johan; Fosså, Sophie D; Steen, Rita; Nustad, Kjell; Bolstad, Nils
2018-02-01
Human Chorionic Gonadotropin (hCG) is produced by germ cell tumors, but can also be elevated in benign conditions such as primary hypogonadism, where hCG is produced by the pituitary gland. In our experience, the reference limits for hCG (Elecsys hCG+β-assay, Roche Diagnostics), were unnecessarily high and did not reflect levels encountered in clinical practice. We wanted to establish new reference limits to increase the clinical utility of the hCG-assay. We analysed hCG in serum samples from a healthy adult population and in a cohort of testicular cancer survivors. The gonadotropins LH and FSH were measured in the cohort and in a selection of the reference population to assess gonadal function. We found low hCG levels for all men and women <45years (97.5 percentiles 0.1 and 0.2IU/L, respectively) from the healthy population (n=795) having normal FSH and LH. Due to assay limitations, we suggest a common reference limit of <0.3IU/L. For the age group ≥45, the 97.5 percentiles in the healthy population were 0.5IU/L for men and 6.0IU/L for women. In all subjects from both the reference population and the cohort (n=732), hCG levels exceeding the reference limit could be fully explained by reduced gonadal function indicated by elevated LH and FSH levels. The Elecsys hCG+β-assay should have lower reference limits than recommended by the manufacturer, with important implications for tumor follow-up. Elevated hCG is rare with intact gonadal function, both in a normal population and among survivors of testicular cancer, and should lead to further investigations when encountered in clinical practice. Copyright © 2017 Oslo University Hospital. Published by Elsevier Inc. All rights reserved.
Estimation of diagnostic test accuracy without full verification: a review of latent class methods
Collins, John; Huynh, Minh
2014-01-01
The performance of a diagnostic test is best evaluated against a reference test that is without error. For many diseases, this is not possible, and an imperfect reference test must be used. However, diagnostic accuracy estimates may be biased if inaccurately verified status is used as the truth. Statistical models have been developed to handle this situation by treating disease as a latent variable. In this paper, we conduct a systematized review of statistical methods using latent class models for estimating test accuracy and disease prevalence in the absence of complete verification. PMID:24910172
Cayuela, Jean-Michel; Mauté, Carole; Fabre, Anne-Lise; Nibourel, Olivier; Dulucq, Stéphanie; Delabesse, Eric; Villarèse, Patrick; Hayette, Sandrine; Mozziconacci, Marie-Joelle; Macintyre, Elizabeth
2015-10-01
Performance of methods used for molecular diagnostics must be closely controlled by regular analysis of internal quality controls. However, conditioning, shipping and long lasting storage of nucleic acid controls remain problematic. Therefore, we evaluated the minicapsule-based innovative process developed by Imagene (Evry, France) for implementing DNA and RNA controls designed for clonality assessment of lymphoproliferations and BCR-ABL1 mRNA quantification, respectively. DNA samples were extracted from 12 cell lines selected for giving specific amplifications with most BIOMED-2 PCR tubes. RNA samples were extracted from 8 cell line mixtures expressing various BCR-ABL1 transcript levels. DNA and RNA were encapsulated by Imagene and shipped at room temperature to participating laboratories. Biologists were asked to report quality data of recovered nucleic acids as well as PCR results. Encapsulated nucleic acids samples were easily and efficiently recovered from minicapsules. The expected rearrangements at immunoglobulin, T-cell receptor and BCL2 loci were detected in DNA samples by all laboratories. Quality of RNA was consistent between laboratories and met the criteria requested for quantification of BCR-ABL1 transcripts. Expression levels measured by the 5 laboratories were within ±2 fold interval from the corresponding pre-encapsulation reference value. Moreover aging studies of encapsulated RNA simulating up to 100 years storage at room temperature show no bias in quantitative outcome. Therefore, Imagene minicapsules are suitable for storage and distribution at room temperature of genetic material designed for proficiency control of molecular diagnostic methods based on end point or real-time quantitative PCR. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Giordano, P C; Plancke, A; Van Meir, C A; Janssen, C A H; Kok, P J M J; Van Rooijen-Nijdam, I H; Tanis, B C; van Huisseling, J C M; Versteegh, F G A
2006-08-01
We have offered, for the first time in The Netherlands, carrier diagnostics for hemoglobinopathies (HbP) to early pregnant women. The aim of this study was to establish whether carrier analysis would be welcome by the public and feasible at the outpatient level. One hundred and thirty-nine randomly selected women were informed and offered basic carrier diagnostics at the first pregnancy control. Carrier diagnostics was accepted by 136 women (97.8%). The population consisted of 31% of recent immigrants and 69% of native Dutch. One carrier of HbS and one of beta-thalassemia were found, both among the group of the recent immigrants. In both cases, partners were tested excluding a couple at risk. In addition, five carriers of alpha(+)-thalassemia were diagnosed at the molecular level, one of them in the native Dutch population. Basic carrier analysis was done both at the Hospital Laboratory and at the Reference Laboratory. No discrepancies were found. This pilot study shows that (1) as predicted the prevalence of risk-related HbP and of alpha(+)-thalassemia is high in the immigrant population. (2) The compliance with carrier analysis in both native Dutch and immigrants is virtually total and (3) carrier diagnosis in early pregnancy and partner analysis in Hospital Laboratories is possible and is an effective tool for primary prevention of HbP in The Netherlands.
Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients.
Iyengar, S S; Morgan-Hughes, G; Ukoumunne, O; Clayton, B; Davies, E J; Nikolaou, V; Hyde, C J; Shore, A C; Roobottom, C A
2016-02-01
To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥ 50%) stenosis and secondarily as the presence of severe (≥ 70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Schiffman, Eric L.; Truelove, Edmond L.; Ohrbach, Richard; Anderson, Gary C.; John, Mike T.; List, Thomas; Look, John O.
2011-01-01
AIMS The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. An overview is presented, including Axis I and II methodology and descriptive statistics for the study participant sample. This paper details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. Validity testing for the Axis II biobehavioral instruments was based on previously validated reference standards. METHODS The Axis I reference standards were based on the consensus of 2 criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion exam reliability was also assessed within study sites. RESULTS Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas ≥ 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion exam agreement with reference standards was excellent (k ≥ 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). CONCLUSION The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods. PMID:20213028
Diagnostic Accuracy of the Slump Test for Identifying Neuropathic Pain in the Lower Limb.
Urban, Lawrence M; MacNeil, Brian J
2015-08-01
Diagnostic accuracy study with nonconsecutive enrollment. To assess the diagnostic accuracy of the slump test for neuropathic pain (NeP) in those with low to moderate levels of chronic low back pain (LBP), and to determine whether accuracy of the slump test improves by adding anatomical or qualitative pain descriptors. Neuropathic pain has been linked with poor outcomes, likely due to inadequate diagnosis, which precludes treatment specific for NeP. Current diagnostic approaches are time consuming or lack accuracy. A convenience sample of 21 individuals with LBP, with or without radiating leg pain, was recruited. A standardized neurosensory examination was used to determine the reference diagnosis for NeP. Afterward, the slump test was administered to all participants. Reports of pain location and quality produced during the slump test were recorded. The neurosensory examination designated 11 of the 21 participants with LBP/sciatica as having NeP. The slump test displayed high sensitivity (0.91), moderate specificity (0.70), a positive likelihood ratio of 3.03, and a negative likelihood ratio of 0.13. Adding the criterion of pain below the knee significantly increased specificity to 1.00 (positive likelihood ratio = 11.9). Pain-quality descriptors did not improve diagnostic accuracy. The slump test was highly sensitive in identifying NeP within the study sample. Adding a pain-location criterion improved specificity. Combining the diagnostic outcomes was very effective in identifying all those without NeP and half of those with NeP. Limitations arising from the small and narrow spectrum of participants with LBP/sciatica sampled within the study prevent application of the findings to a wider population. Diagnosis, level 4-.
Mushlin, A I; Mooney, C; Grow, V; Phelps, C E
1994-01-01
To determine the value of diagnostic information to patients with suspected multiple sclerosis (MS). Because treatment choices would be only minimally affected by earlier diagnosis for most patients with this clinical problem, this study assessed the "nondecisional" value of diagnosis. Prospective survey of patients before and after diagnostic workup, including imaging with magnetic resonance scanning. We assessed the effect of diagnostic information on patients' sense of well-being, as well as direct measures of the utility of information (using time trade-off and willingness-to-pay techniques). Patients referred from primary care practices for diagnostic workup for suspected MS to neurology clinics and practices. Sixty-eight individuals, mean age 37.5 years, 53 female and 15 male. Thirty-one patients were classified as having "probable MS," and 37 were classified as having "possible MS" by the examining neurologist before workup. Present and future health perception, uncertainty about diagnosis-prognosis, and level of anxiety. Willingness to pay for diagnostic information, quality of life as measured by the time trade-off technique, and psychological state of the patient before and after diagnosis. Diagnostic uncertainty fell significantly as a result of the diagnostic workup. Most patients (59/62) said that they were better off having received diagnostic information. Although anxiety seemed to be reduced by testing, overall anxiety levels did not decrease as much as anticipated. Patients also became less optimistic about their future health after testing. On average, patients were willing to forgo 4.5 quality-adjusted life days to receive an earlier diagnosis and their quality of life after diagnosis improved slightly. Subgroups of patients differed in their response to diagnostic information. Those in whom no definitive diagnosis emerged tend to be more anxious rather than being reassured by the "negative" workup. Individuals with "positive" workups became less anxious and expressed favorable feelings about the diagnostic workup even though they often faced a chronic disease. Overall, the diagnostic workup seemed to benefit patients and improve their sense of well-being. However, whether the effects were beneficial or not depended on the results of the diagnostic workup itself. In clinical practice the decision to undergo testing in situations in which definitive treatment is unavailable should be individualized. The potential for negative as well as positive consequences should be recognized.
Hunt, Brady; Fregnani, José Humberto Tavares Guerreiro; Schwarz, Richard A; Pantano, Naitielle; Tesoni, Suelen; Possati-Resende, Júlio César; Antoniazzi, Marcio; de Oliveira Fonseca, Bruno; de Macêdo Matsushita, Graziela; Scapulatempo-Neto, Cristovam; Kerr, Ligia; Castle, Philip E; Schmeler, Kathleen; Richards-Kortum, Rebecca
2018-06-01
Cervical cancer is a leading cause of death in underserved areas of Brazil. This prospective randomized trial involved 200 women in southern/central Brazil with abnormal Papanicolaou tests. Participants were randomized by geographic cluster and referred for diagnostic evaluation either at a mobile van upon its scheduled visit to their local community, or at a central hospital. Participants in both arms underwent colposcopy, in vivo microscopy, and cervical biopsies. We compared rates of diagnostic follow-up completion between study arms, and also evaluated the diagnostic performance of in vivo microscopy compared with colposcopy. There was a 23% absolute and 37% relative increase in diagnostic follow-up completion rates for patients referred to the mobile van (102/117, 87%) compared with the central hospital (53/83, 64%; P = 0.0001; risk ratio = 1.37, 95% CI, 1.14-1.63). In 229 cervical sites in 144 patients, colposcopic examination identified sites diagnosed as cervical intraepithelial neoplasia grade 2 or more severe (CIN2+; 85 sites) with a sensitivity of 94% (95% CI, 87%-98%) and specificity of 50% (95% CI, 42%-58%). In vivo microscopy with real-time automated image analysis identified CIN2+ with a sensitivity of 92% (95% CI, 84%-97%) and specificity of 48% (95% CI, 40%-56%). Women referred to the mobile van were more likely to complete their diagnostic follow-up compared with those referred to a central hospital, without compromise in clinical care. In vivo microscopy in a mobile van provides automated diagnostic imaging with sensitivity and specificity similar to colposcopy. Cancer Prev Res; 11(6); 359-70. ©2018 AACR . ©2018 American Association for Cancer Research.
European and Mexican vs US diagnostic extracts of Bermuda grass and cat in skin testing.
Larenas-Linnemann, Désirée; Cruz, Alfredo Arias; Gutierrez, Isabel Rojo; Rodriguez, Pablo; Shah-Hosseini, Kijawasch; Michels, Alexandra; Mösges, Ralph
2011-05-01
Laboratory testing of various diagnostic extracts has shown lower potencies for several European and Mexican extracts relative to the US Food and Drug Administration (FDA) reference (10,000 BAU/mL). Quantitative skin prick testing (QSPT) with Dermatophagoides pteronyssinus extracts have previously shown a similar picture. To compare European and Mexican Bermuda grass (BG) and cat diagnostic extracts against an FDA-validated extract using QSPT. Six diagnostic BG and cat extracts (1 reference FDA extract, 3 European extracts, 1 imported nonstandardized extract from the United States, and 1 Mexican extract) were tested with quadruplicate QSPT, as a concentrate and as 2 serial 2-fold dilutions, in cat and BG allergic individuals. BG showed good dose response in wheal size for the concentrate (1:2-1:4 dilutions; steep part of the curve). Cat showed poorer dose response. The Wilcoxon test for linked random samples was used to investigate whether the distribution of the reference differed from each of the test extracts to a statistically significant degree (2-sided asymptotic significance, α = .05). All BG and 2 cat extracts were statistically less potent than the 10,000 BAU/mL US reference. European BG extracts were 7,700, 4,100, and 1,600 BAU/mL, and cat extracts were 12,500, 4,400, and 5,100 BAU/mL. The potency of some diagnostic extracts of BG and cat used in Europe, Mexico, and the United States differs, with the US extracts being generally more potent. On the basis of provocation tests, optimal diagnostic concentrations should be determined. Similar comparisons using other manufacturers and therapeutic extracts might be interesting. Copyright © 2011 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Lança, L; Silva, A; Alves, E; Serranheira, F; Correia, M
2008-01-01
Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in the Lisbon area and to compare the collected data with European references [Commission of European Communities (CEC) guidelines]. The results show that in four examinations (skull, chest, lumbar spine and pelvis), there is a strong tendency of using exposure times above the European recommendation. The X-ray tube potential values (in kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region), radiographic practice does not comply with CEC guidelines concerning exposure techniques. Further national/local studies are recommended with the objective to improve exposure optimisation and technical procedures in plain radiography. This study also suggests the need to establish national/local diagnostic reference levels and to proceed to effective measurements for exposure optimisation.
Computer-Aided Medical Diagnosis. Literature Review
1978-12-15
Croft found a 13% difference in diagnostic accuracy. He considered this difference insignificant in relation to the diagnostic differences caused ...type of diseases diagnosed probably are the major cause of cross-study variability in diagnostic accuracy. The consistency of diagnostic accuracy...REFERENCES ALPEROVITCH, A. and FRAGU, P., A suggestion for an effective use of a computer-aided diagnosis system in screening for hyperthyroidism , Method
Dheda, Keertan; Van-Zyl Smit, Richard N.; Sechi, Leonardo A.; Badri, Motasim; Meldau, Richard; Symons, Gregory; Khalfey, Hoosein; Carr, Igshaan; Maredza, Alice; Dawson, Rodney; Wainright, Helen; Whitelaw, Andrew; Bateman, Eric D.; Zumla, Alimuddin
2009-01-01
Background Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. Methods We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal Findings Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. Conclusion Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings. PMID:19277111
Truong, Quynh A; Knaapen, Paul; Pontone, Gianluca; Andreini, Daniele; Leipsic, Jonathon; Carrascosa, Patricia; Lu, Bin; Branch, Kelley; Raman, Subha; Bloom, Stephen; Min, James K
2015-10-01
Dual-energy CT (DECT) has potential to improve myocardial perfusion for physiologic assessment of coronary artery disease (CAD). Diagnostic performance of rest-stress DECT perfusion (DECTP) is unknown. DECIDE-Gold is a prospective multicenter study to evaluate the accuracy of DECT to detect hemodynamic (HD) significant CAD, as compared to fractional flow reserve (FFR) as a reference standard. Eligible participants are subjects with symptoms of CAD referred for invasive coronary angiography (ICA). Participants will undergo DECTP, which will be performed by pharmacological stress, and participants will subsequently proceed to ICA and FFR. HD-significant CAD will be defined as FFR ≤ 0.80. In those undergoing myocardial stress imaging (MPI) by positron emission tomography (PET), single photon emission computed tomography (SPECT) or cardiac magnetic resonance (CMR) imaging, ischemia will be graded by % ischemic myocardium. Blinded core laboratory interpretation will be performed for CCTA, DECTP, MPI, ICA, and FFR. Primary endpoint is accuracy of DECTP to detect ≥1 HD-significant stenosis at the subject level when compared to FFR. Secondary and tertiary endpoints are accuracies of combinations of DECTP at the subject and vessel levels compared to FFR and MPI. DECIDE-Gold will determine the performance of DECTP for diagnosing ischemia.
Vodovatov, A V; Balonov, M I; Golikov, V Yu; Shatsky, I G; Chipiga, L A; Bernhardsson, C
2017-04-01
In 2009-2014, dose surveys aimed to collect adult patient data and parameters of most common radiographic examinations were performed in six Russian regions. Typical patient doses were estimated for the selected examinations both in entrance surface dose and in effective dose. 75%-percentiles of typical patient effective dose distributions were proposed as preliminary regional diagnostic reference levels (DRLs) for radiography. Differences between the 75%-percentiles of regional typical patient dose distributions did not exceed 30-50% for the examinations with standardized clinical protocols (skull, chest and thoracic spine) and a factor of 1.5 for other examinations. Two different approaches for establishing national DRLs were evaluated: as a 75%-percentile of a pooled regional sample of patient typical doses (pooled method) and as a median of 75%-percentiles of regional typical patient dose distributions (median method). Differences between pooled and median methods for effective dose did not exceed 20%. It was proposed to establish Russian national DRLs in effective dose using a pooled method. In addition, the local authorities were granted an opportunity to establish regional DRLs if the local radiological practice and typical patient dose distributions are significantly different. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
İnal, Tolga; Ataç, Gökçe
2014-01-01
PURPOSE We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. MATERIALS AND METHODS Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. RESULTS The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. CONCLUSION This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey. PMID:24317331
Spectroscopic diagnostics for bacteria in biologic sample
El-Sayed, Mostafa A.; El-Sayed, Ivan H.
2002-01-01
A method to analyze and diagnose specific bacteria in a biologic sample using spectroscopy is disclosed. The method includes obtaining the spectra of a biologic sample of a non-infected patient for use as a reference, subtracting the reference from the spectra of an infected sample, and comparing the fingerprint regions of the resulting differential spectrum with reference spectra of bacteria in saline. Using this diagnostic technique, specific bacteria can be identified sooner and without culturing, bacteria-specific antibiotics can be prescribed sooner, resulting in decreased likelihood of antibiotic resistance and an overall reduction of medical costs.
Schiffman, Eric L; Truelove, Edmond L; Ohrbach, Richard; Anderson, Gary C; John, Mike T; List, Thomas; Look, John O
2010-01-01
The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. The aim of this article is to provide an overview of the project's methodology, descriptive statistics, and data for the study participant sample. This article also details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. The Axis I reference standards were based on the consensus of two criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion examination reliability was also assessed within study sites. Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas > or = 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion examiner agreement with reference standards was excellent (k > or = 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods.
Lithgow, Kirstie; Chin, Alex; Debert, Chantel T; Kline, Gregory A
2018-04-02
Growth hormone deficiency (GHD) is a potential consequence of traumatic brain injury (TBI), including sport-related concussion (SRC). GH stimulation testing is required for definitive diagnosis; however, this is resource intensive and can be associated with adverse symptoms or risks. Measurement of serum IGF-1 is more practical and accessible, and pituitary tumour patients with hypopituitarism and low serum IGF-1 have been shown to have a high probability of GHD. We aimed to evaluate IGF-1 measurement for diagnosing GHD in our local TBI population. We conducted a retrospective chart review of patients evaluated for GHD at the TBI clinic and referred for GH stimulation testing with insulin tolerance test (ITT) or glucagon stimulation test (GST) since December 2013. We obtained demographics, TBI severity, IGF-1, data pertaining to pituitary function, and GH stimulation results. IGF-1 values were used to calculate z-scores per age and gender specific reference ranges. Receiver operator curve analysis was performed to evaluate diagnostic threshold of IGF-1 z-score for determining GHD by GST or ITT. Sixty four patient charts were reviewed. 48 patients had mild, six had moderate, eight had severe TBI, and two had non-traumatic brain injuries. 47 patients underwent ITT or GST. 27 were confirmed to have GHD (peak hGH < 5 μg/L). IGF-1 level was within the age and gender specific reference range for all patients with confirmed GHD following GH stimulation testing. Only one patient had a baseline IGF-1 level below the age and gender specific reference range; this patient had a normal response to GH stimulation testing. ROC analysis showed IGF-1 z-score AUC f, confirming lack of diagnostic utility. Baseline IGF-1 is not a useful predictor of GHD in our local TBI population, and therefore has no value as a screening tool. TBI patients undergoing pituitary evaluation will require a dynamic test of GH reserve.
Madani, A S; Shamsian, A A; Hedayati-Moghaddam, M R; Fathi-Moghadam, F; Sabooni, M R; Mirmortazavi, A; Golmohamadi, M
2013-08-01
Temporomandibular disorders (TMD) are defined as clinical conditions that involve the masticatory muscles, temporomandibular joint (TMJ) or both. The aim of this study was to evaluate serum 17β-oestradiol and progesterone levels in menstruating women affected by internal derangement of the TMJ. A total of 142 women (mean age 30·2 ± 6·7) who referred to medical diagnostic laboratory of Iranian Academic Centre for Education, Culture and Research (ACECR), Mashhad Branch, were enrolled during 2007 and 2008. Forty-seven individuals had disc displacement with reduction (Group IIa) according to Research Diagnostic Criteria (RDC)/TMD Axis I diagnosis. Radioimmunoassay was used for the detection of serum 17β-oestradiol and progesterone levels in all 142 subjects. The mean progesterone level was significantly higher in control group (11·6 ± 10·4 ng mL(-1) ) compared to women with TMD (8·4 ± 6·8 ng mL(-1) , P = 0·03). No significant difference was found in two groups regarding 17β-oestradiol level. Lower progesterone level in women with TMD can suggest the more important role of this hormone in the development of the disorder. © 2013 John Wiley & Sons Ltd.
Aithal, Venkatesh; Kei, Joseph; Driscoll, Carlie; Murakoshi, Michio; Wada, Hiroshi
2018-02-01
Diagnosing conductive conditions in newborns is challenging for both audiologists and otolaryngologists. Although high-frequency tympanometry (HFT), acoustic stapedial reflex tests, and wideband absorbance measures are useful diagnostic tools, there is performance measure variability in their detection of middle ear conditions. Additional diagnostic sensitivity and specificity measures gained through new technology such as sweep frequency impedance (SFI) measures may assist in the diagnosis of middle ear dysfunction in newborns. The purpose of this study was to determine the test performance of SFI to predict the status of the outer and middle ear in newborns against commonly used reference standards. Automated auditory brainstem response (AABR), HFT (1000 Hz), transient evoked otoacoustic emission (TEOAE), distortion product otoacoustic emission (DPOAE), and SFI tests were administered to the study sample. A total of 188 neonates (98 males and 90 females) with a mean gestational age of 39.4 weeks were included in the sample. Mean age at the time of testing was 44.4 hr. Diagnostic accuracy of SFI was assessed in terms of its ability to identify conductive conditions in neonates when compared with nine different reference standards (including four single tests [AABR, HFT, TEOAE, and DPOAE] and five test batteries [HFT + DPOAE, HFT + TEOAE, DPOAE + TEOAE, DPOAE + AABR, and TEOAE + AABR]), using receiver operating characteristic (ROC) analysis and traditional test performance measures such as sensitivity and specificity. The test performance of SFI against the test battery reference standard of HFT + DPOAE and single reference standard of HFT was high with an area under the ROC curve (AROC) of 0.87 and 0.82, respectively. Although the HFT + DPOAE test battery reference standard performed better than the HFT reference standard in predicting middle ear conductive conditions in neonates, the difference in AROC was not significant. Further analysis revealed that the highest sensitivity and specificity for SFI (86% and 88%, respectively) was obtained when compared with the reference standard of HFT + DPOAE. Among the four single reference standards, SFI had the highest sensitivity and specificity (76% and 88%, respectively) when compared against the HFT reference standard. The high test performance of SFI against the HFT and HFT + DPOAE reference standards indicates that the SFI measure has appropriate diagnostic accuracy in detection of conductive conditions in newborns. Hence, the SFI test could be used as adjunct tool to identify conductive conditions in universal newborn hearing screening programs, and can also be used in diagnostic follow-up assessments. American Academy of Audiology
Reference values of elements in human hair: a systematic review.
Mikulewicz, Marcin; Chojnacka, Katarzyna; Gedrange, Thomas; Górecki, Henryk
2013-11-01
The lack of systematic review on reference values of elements in human hair with the consideration of methodological approach. The absence of worldwide accepted and implemented universal reference ranges causes that hair mineral analysis has not become yet a reliable and useful method of assessment of nutritional status and exposure of individuals. Systematic review of reference values of elements in human hair. PubMed, ISI Web of Knowledge, Scopus. Humans, hair mineral analysis, elements or minerals, reference values, original studies. The number of studies screened and assessed for eligibility was 52. Eventually, included in the review were 5 papers. The studies report reference ranges for the content of elements in hair: macroelements, microelements, toxic elements and other elements. Reference ranges were elaborated for different populations in the years 2000-2012. The analytical methodology differed, in particular sample preparation, digestion and analysis (ICP-AES, ICP-MS). Consequently, the levels of hair minerals reported as reference values varied. It is necessary to elaborate the standard procedures and furtherly validate hair mineral analysis and deliver detailed methodology. Only then it would be possible to provide meaningful reference ranges and take advantage of the potential that lies in Hair Mineral Analysis as a medical diagnostic technique. Copyright © 2013 Elsevier B.V. All rights reserved.
DEB: A Diagnostic Experience Browser using similarity networks
NASA Technical Reports Server (NTRS)
Casadaban, Cyprian E.
1990-01-01
Diagnostic Experience Browser (DEB): a fusion of knowledge base and data base that allows users to examine only the data which is most useful to them is described. The system combines a data base of historical cases of diagnostic trouble-shooting experience with similarity networks. A menu-driven natural language interface receives input about the user's current problem. Similarity networks provide the user with references to past cases that are most similar or most related to those they now face. The user can then choose the case that is most pertinent and browse its full textual description which, in turn, may include references to other related cases.
Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M
2016-05-01
To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Donald L.; Hilohi, C. Michael; Spelic, David C.
2012-10-15
Purpose: To determine patient radiation doses from interventional cardiology procedures in the U.S and to suggest possible initial values for U.S. benchmarks for patient radiation dose from selected interventional cardiology procedures [fluoroscopically guided diagnostic cardiac catheterization and percutaneous coronary intervention (PCI)]. Methods: Patient radiation dose metrics were derived from analysis of data from the 2008 to 2009 Nationwide Evaluation of X-ray Trends (NEXT) survey of cardiac catheterization. This analysis used deidentified data and did not require review by an IRB. Data from 171 facilities in 30 states were analyzed. The distributions (percentiles) of radiation dose metrics were determined for diagnosticmore » cardiac catheterizations, PCI, and combined diagnostic and PCI procedures. Confidence intervals for these dose distributions were determined using bootstrap resampling. Results: Percentile distributions (advisory data sets) and possible preliminary U.S. reference levels (based on the 75th percentile of the dose distributions) are provided for cumulative air kerma at the reference point (K{sub a,r}), cumulative air kerma-area product (P{sub KA}), fluoroscopy time, and number of cine runs. Dose distributions are sufficiently detailed to permit dose audits as described in National Council on Radiation Protection and Measurements Report No. 168. Fluoroscopy times are consistent with those observed in European studies, but P{sub KA} is higher in the U.S. Conclusions: Sufficient data exist to suggest possible initial benchmarks for patient radiation dose for certain interventional cardiology procedures in the U.S. Our data suggest that patient radiation dose in these procedures is not optimized in U.S. practice.« less
Bianchi, Vincenza; Ivaldi, Alessandra; Raspagni, Alessia; Arfini, Carlo; Vidali, Matteo
2011-01-01
Contrasting data are available on the diagnostic accuracy of carbohydrate-deficient transferrin (CDT) during pregnancy. These differences may depend in part on how CDT was evaluated and expressed. Here, we report on variations of CDT levels in pregnant women using the high performance liquid chromatography (HPLC) candidate reference method. Alanine aminotransferase, aspartate aminotransferase, gamma-glutamyltransferase, mean corpuscular volume, serum transferrin, urine and serum ethyl glucuronide and CDT were measured in 64 women, self-reporting as non-alcohol abusers (age: median 34, IQR: 28-38), at different stages of normal pregnancy (gestational weeks: median 28, IQR: 8-33). CDT was expressed as percentage of disialotransferrin to total transferrin (%CDT). Transferrin was associated with both %CDT (r = 0.66; P < 0.001) and gestational week (r = 0.68; P < 0.001). Interestingly, %CDT was highly correlated with gestational week (r = 0.77; P < 0.001), even after controlling for the effect of transferrin. Moreover, statistically significant differences in %CDT were also evident between women grouped for pregnancy trimester (first trimester: mean 1.01% (SD 0.19); second trimester: 1.30% (SD 0.14); third trimester: 1.53% (SD 0.22); ANOVA P < 0.001). Trend analysis confirmed a proportional increase of %CDT along with pregnancy trimesters (P < 0.001). %CDT, measured with the HPLC candidate reference method, is independently associated with gestational week. Differently from what has been previously reported or expected, the relationship between pregnancy and CDT could be more complex. The diagnostic accuracy of CDT for detecting alcohol abuse in a legal context may be limited in pregnant women and the effect of gestational age should be considered.
Chaikriangkrai, Kongkiat; Jhun, Hye Yeon; Shantha, Ghanshyam Palamaner Subash; Abdulhak, Aref Bin; Tandon, Rudhir; Alqasrawi, Musab; Klappa, Anthony; Pancholy, Samir; Deshmukh, Abhishek; Bhama, Jay; Sigurdsson, Gardar
2018-07-01
In aortic stenosis patients referred for surgical and transcatheter aortic valve replacement (AVR), the evidence of diagnostic accuracy of coronary computed tomography angiography (CCTA) has been limited. The objective of this study was to investigate the diagnostic accuracy of CCTA for significant coronary artery disease (CAD) in patients referred for AVR using invasive coronary angiography (ICA) as the gold standard. We searched databases for all diagnostic studies of CCTA in patients referred for AVR, which reported diagnostic testing characteristics on patient-based analysis required to pool summary sensitivity, specificity, positive-likelihood ratio, and negative-likelihood ratio. Significant CAD in both CCTA and ICA was defined by >50% stenosis in any coronary artery, coronary stent, or bypass graft. Thirteen studies evaluated 1498 patients (mean age, 74 y; 47% men; 76% transcatheter AVR). The pooled prevalence of significant stenosis determined by ICA was 43%. Hierarchical summary receiver-operating characteristic analysis demonstrated a summary area under curve of 0.96. The pooled sensitivity, specificity, and positive-likelihood and negative-likelihood ratios of CCTA in identifying significant stenosis determined by ICA were 95%, 79%, 4.48, and 0.06, respectively. In subgroup analysis, the diagnostic profiles of CCTA were comparable between surgical and transcatheter AVR. Despite the higher prevalence of significant CAD in patients with aortic stenosis than with other valvular heart diseases, our meta-analysis has shown that CCTA has a suitable diagnostic accuracy profile as a gatekeeper test for ICA. Our study illustrates a need for further study of the potential role of CCTA in preoperative planning for AVR.
40 CFR 1068.95 - What materials does this part reference?
Code of Federal Regulations, 2011 CFR
2011-07-01
... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...
40 CFR 1068.95 - What materials does this part reference?
Code of Federal Regulations, 2010 CFR
2010-07-01
... material from the Society of Automotive Engineers that we have incorporated by reference. The first column... reference it. Anyone may purchase copies of these materials from the Society of Automotive Engineers, 400... Materials Document number and name Part 1068reference SAE J1930, Electrical/Electronic Systems Diagnostic...
Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E
2016-02-01
It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.
Second opinion oral pathology referrals in New Zealand.
Seo, B; Hussaini, H M; Rich, A M
2017-04-01
Referral for a second opinion is an important aspect of pathology practice, which reduces the rate of diagnostic error and ensures consistency with diagnoses. The Oral Pathology Centre (OPC) is the only specialist oral diagnostic centre in New Zealand. OPC provides diagnostic services to dentists and dental specialists throughout New Zealand and acts as a referral centre for second opinions for oral pathology specimens that have been sent to anatomical pathologists. The aim of this study was to review second opinion referral cases sent to the OPC over a 15-year period and to assess the levels of concordance between the original and final diagnoses. The findings indicated that the majority of referred cases were odontogenic lesions, followed by connective tissue, epithelial and salivary lesions. The most prevalent diagnoses were ameloblastoma and keratocystic odontogenic tumour, followed by oral squamous cell carcinoma. Discordant diagnoses were recorded in 24% of cases. Diagnostic discrepancies were higher in odontogenic and salivary gland lesions, resulting in the change of diagnoses. Second opinion of oral pathology cases should be encouraged in view of the relative rarity of these lesions in general pathology laboratories and the rates of diagnostic discrepancy, particularly for odontogenic and salivary gland lesions. Copyright © 2017 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.
Saliva as a non-invasive diagnostic tool for inflammation and insulin-resistance
Desai, Gauri S; Mathews, Suresh T
2014-01-01
Saliva has been progressively studied as a non-invasive and relatively stress-free diagnostic alternative to blood. Currently, saliva testing is used for clinical assessment of hormonal perturbations, detection of HIV antibodies, DNA analysis, alcohol screening, and drug testing. Recently, there has been increasing interest in evaluating the diagnostic potential of saliva in obesity, inflammation, and insulin-resistance. Current literature has demonstrated elevated levels of inflammatory biomarkers including C-reactive protein, tumor necrosis factor-α, interleukin-6, and interferon-γ in saliva of obese/overweight children and adults. Salivary antioxidant status has also been studied as a measure of oxidative stress in individuals with type 2 diabetes. Further, several studies have demonstrated correlations of salivary markers of stress and insulin resistance including cortisol, insulin, adiponectin, and resistin with serum concentrations. These findings suggest the potential diagnostic value of saliva in health screening and risk stratification studies, particularly in the pediatric population, with implications for inflammatory, metabolic and cardiovascular conditions. However, additional studies are required to standardize saliva collection and storage procedures, validate analytical techniques for biomarker detection, and establish reference ranges for routine clinical use. The purpose of this review is to summarize and evaluate recent advancements in using saliva as a diagnostic tool for inflammation and insulin-resistance. PMID:25512775
Ingilizova, K; Vassileva, J; Rupova, I; Pavlova, A
2005-01-01
From February 2002 to November 2003 the National Centre of Radiobiology and Radiation Protection conducted a PHARE twinning project 'Radiation Protection and Safety at Medical Use of Ionising Radiation'. The main purposes of the project were the harmonization of Bulgarian legislation in the field of radiation protection with EC Directives 96/29 and 97/43 Euratom, and the establishment of appropriate institutional infrastructure and administrative framework for their implementation. This paper presents the main results of the project: elaboration of Ordinance for Protection of Individuals from Medical Exposure; performance of a national survey of distribution of patient doses in diagnostic radiology and of administered activities in nuclear medicine and establishment of national reference levels for the most common diagnostic procedures.
Definition of periprosthetic joint infection: is there a consensus?
Parvizi, Javad; Jacovides, Christina; Zmistowski, Benjamin; Jung, Kwang Am
2011-11-01
The diagnosis of periprosthetic joint infection (PJI) continues to pose a challenge. While many diagnostic criteria have been proposed, a gold standard for diagnosis is lacking. Use of multiple diagnostic criteria within the joint arthroplasty community raises concerns in patient treatment and comparison of research pertaining to PJI. We (1) determined the variation in existing diagnostic criteria, (2) compared the existing criteria to a proposed new set of criteria that incorporates aspirate cell count analysis, and (3) investigated the variations between the existing criteria and the proposed criteria. We retrospectively identified 182 patients undergoing 192 revision knee arthroplasties who had a preoperative joint aspiration analysis at our institution between April 2002 and November 2009. We excluded 20 cases due to insufficient laboratory parameters, leaving 172 cases for analysis. We applied six previously published sets of diagnostic criteria for PJI to determine the variation in its incidence using each set of criteria. We then compared these diagnostic criteria to our proposed new criteria and investigated cases where disagreement occurred. We identified 41 cases (24%) in which at least one established criteria set classified the case as infected while at least one other criteria set classified the case as uninfected. With our proposed criteria, the infected/uninfected ratio was 92/80. The proposed criteria had a large variance in sensitivity (54%-100%), specificity (39%-100%), and accuracy (53%-100%) when using each of the established criteria sets as the reference standard. The discrepancy between definitions of infection complicates interpretation of the literature and the treatment of failed TKAs owing to PJI. Based on our findings, we suggest establishing a common set of diagnostic criteria utilizing aspirate analysis to improve the treatment of PJI and facilitate interpretation of the literature. Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Accuracy of physical examination for chronic lumbar radiculopathy
2013-01-01
Background Clinical examination of patients with chronic lumbar radiculopathy aims to clarify whether there is nerve root impingement. The aims of this study were to investigate the association between findings at clinical examination and nerve root impingement, to evaluate the accuracy of clinical index tests in a specialised care setting, and to see whether imaging clarifies the cause of chronic radicular pain. Methods A total of 116 patients referred with symptoms of lumbar radiculopathy lasting more than 12 weeks and at least one positive index test were included. The tests were the straight leg raising test, and tests for motor muscle strength, dermatome sensory loss, and reflex impairment. Magnetic resonance imaging (n = 109) or computer tomography (n = 7) were imaging reference standards. Images were analysed at the level of single nerve root(s), and nerve root impingement was classified as present or absent. Sensitivities, specificities, and positive and negative likelihood ratios (LR) for detection of nerve root impingement were calculated for each individual index test. An overall clinical evaluation, concluding on the level and side of the radiculopathy, was performed. Results The prevalence of disc herniation was 77.8%. The diagnostic accuracy of individual index tests was low with no tests reaching positive LR >4.0 or negative LR <0.4. The overall clinical evaluation was slightly more accurate, with a positive LR of 6.28 (95% CI 1.06–37.21) for L4, 1.74 (95% CI 1.04–2.93) for L5, and 1.29 (95% CI 0.97–1.72) for S1 nerve root impingement. An overall clinical evaluation, concluding on the level and side of the radiculopathy was also performed, and receiver operating characteristic (ROC) analysis with area under the curve (AUC) calculation for diagnostic accuracy of this evaluation was performed. Conclusions The accuracy of individual clinical index tests used to predict imaging findings of nerve root impingement in patients with chronic lumbar radiculopathy is low when applied in specialised care, but clinicians’ overall evaluation improves diagnostic accuracy slightly. The tests are not very helpful in clarifying the cause of radicular pain, and are therefore inaccurate for guidance in the diagnostic workup of the patients. The study population was highly selected and therefore the results from this study should not be generalised to unselected patient populations in primary care nor to even more selected surgical populations. PMID:23837886
Samples, Laura S; Rendi, Mara H; Frederick, Paul D; Allison, Kimberly H; Nelson, Heidi D; Morgan, Thomas R; Weaver, Donald L; Elmore, Joann G
2017-08-01
Flat epithelial atypia (FEA) is a relatively new diagnostic term with uncertain clinical significance for surgical management. Any implied risk of invasive breast cancer associated with FEA is contingent upon diagnostic reproducibility, yet little is known regarding its use. Pathologists in the Breast Pathology Study interpreted one of four 60-case test sets, one slide per case, constructed from 240 breast biopsy specimens. An electronic data form with standardized diagnostic categories was used; participants were instructed to indicate all diagnoses present. We assessed participants' use of FEA as a diagnostic term within: 1) each test set; 2) 72 cases classified by reference as benign without FEA; and 3) six cases classified by reference as FEA. 115 pathologists participated, providing 6900 total independent assessments. Notation of FEA ranged from 0% to 35% of the cases interpreted, with most pathologists noting FEA on 4 or more test cases. At least one participant noted FEA in 34 of the 72 benign non-FEA cases. For the 6 reference FEA cases, participant agreement with the case reference FEA diagnosis ranged from 17% to 52%; diagnoses noted by participating pathologists for these FEA cases included columnar cell hyperplasia, usual ductal hyperplasia, atypical lobular hyperplasia, and atypical ductal hyperplasia. We observed wide variation in the diagnosis of FEA among U.S. pathologists. This suggests that perceptions of diagnostic criteria and any implied risk associated with FEA may also vary. Surgical excision following a core biopsy diagnosis of FEA should be reconsidered and studied further. Copyright © 2017 Elsevier Ltd. All rights reserved.
Fetal and maternal dose assessment for diagnostic scans during pregnancy
NASA Astrophysics Data System (ADS)
Rafat Motavalli, Laleh; Miri Hakimabad, Hashem; Hoseinian Azghadi, Elie
2016-05-01
Despite the concerns about prenatal exposure to ionizing radiation, the number of nuclear medicine examinations performed for pregnant women increased in the past decade. This study attempts to better quantify radiation doses due to diagnostic nuclear medicine procedures during pregnancy with the help of our recently developed 3, 6, and 9 month pregnant hybrid phantoms. The reference pregnant models represent the adult female international commission on radiological protection (ICRP) reference phantom as a base template with a fetus in her gravid uterus. Six diagnostic scintigraphy scans using different radiopharmaceuticals were selected as typical diagnostic nuclear medicine procedures. Furthermore, the biokinetic data of radioiodine was updated in this study. A compartment representing iodide in fetal thyroid was addressed explicitly in the biokinetic model. Calculations were performed using the Monte Carlo transport method. Tabulated dose coefficients for both maternal and fetal organs are provided. The comparison was made with the previously published fetal doses calculated for stylized pregnant female phantoms. In general, the fetal dose in previous studies suffers from an underestimation of up to 100% compared to fetal dose at organ level in this study. A maximum of difference in dose was observed for the fetal thyroid compared to the previous studies, in which the traditional models did not contain the fetal thyroid. Cumulated activities of major source organs are primarily responsible for the discrepancies in the organ doses. The differences in fetal dose depend on several other factors including chord length distribution between fetal organs and maternal major source organs, and anatomical differences according to gestation periods. Finally, considering the results of this study, which was based on the realistic pregnant female phantoms, a more informed evaluation of the risks and benefits of the different procedures could be made.
Diagnostic performance of osteocalcin measurements in patients with endogenous Cushing's syndrome.
Belaya, Zhanna E; Iljin, Alexander V; Melnichenko, Galina A; Solodovnikov, Alexander G; Rozhinskaya, Liudmila Y; Dzeranova, Larisa K; Dedov, Ivan I
2016-01-01
The aim of this study was to evaluate the diagnostic performance of osteocalcin (OC), as measured by automated electrochemiluminescence immunoassay (ECLIA), in identifying Cushing's syndrome (CS) in two separate populations: among obese and overweight subjects and among women of postmenopausal age with osteoporosis. Among the 106 referral patients with obesity, CS was confirmed in 42 cases. The patients of the referred population provided late-night salivary cortisol (LNSC), underwent low-dose dexamethasone suppression testing (DST) and were further evaluated until CS was pathologically confirmed. A threshold of OC-8.3 ng ml(-1) differentiated CS among obese and overweight subjects with a sensitivity of 73.8% (95% confidence interval (CI) 58.9-84.7) and a specificity of 96.9% (95% CI 89.3-99.1). The total area under the receiver operating characteristic curve (AUC) was 0.859 (95% CI 0.773-0.945), which was lower than LNSC or DST (P=0.01). In the retrospective portion of the study, the OC levels were evaluated in 67 subjects with newly diagnosed postmenopausal osteoporosis and in 23 patients (older than 45) with newly diagnosed CS and osteoporosis (presence of low traumatic fractures or T-score P-2.5). The diagnostic performance of OC for osteoporosis due to CS was within an AUC of 0.959 (95% CI 0.887-1.00). A threshold for OC of 8.3 ng ml-1 yielded a sensitivity of 95.4% (95% CI 78.2-99.2%) and a specificity of 98.5% (95% CI 92.0-99.7%). Thus, osteocalcin could be used in the diagnostic testing for endogenous hypercortisolism in patients referred to exclude CS and to identify CS among patients of postmenopausal age with osteoporosis.
Diagnostic performance of osteocalcin measurements in patients with endogenous Cushing's syndrome
Belaya, Zhanna E; Iljin, Alexander V; Melnichenko, Galina A; Solodovnikov, Alexander G; Rozhinskaya, Liudmila Y; Dzeranova, Larisa K; Dedov, Ivan I
2016-01-01
The aim of this study was to evaluate the diagnostic performance of osteocalcin (OC), as measured by automated electrochemiluminescence immunoassay (ECLIA), in identifying Cushing's syndrome (CS) in two separate populations: among obese and overweight subjects and among women of postmenopausal age with osteoporosis. Among the 106 referral patients with obesity, CS was confirmed in 42 cases. The patients of the referred population provided late-night salivary cortisol (LNSC), underwent low-dose dexamethasone suppression testing (DST) and were further evaluated until CS was pathologically confirmed. A threshold of OC—8.3 ng ml−1 differentiated CS among obese and overweight subjects with a sensitivity of 73.8% (95% confidence interval (CI) 58.9–84.7) and a specificity of 96.9% (95% CI 89.3–99.1). The total area under the receiver operating characteristic curve (AUC) was 0.859 (95% CI 0.773–0.945), which was lower than LNSC or DST (P=0.01). In the retrospective portion of the study, the OC levels were evaluated in 67 subjects with newly diagnosed postmenopausal osteoporosis and in 23 patients (older than 45) with newly diagnosed CS and osteoporosis (presence of low traumatic fractures or T-score P–2.5). The diagnostic performance of OC for osteoporosis due to CS was within an AUC of 0.959 (95% CI 0.887–1.00). A threshold for OC of 8.3 ng ml-1 yielded a sensitivity of 95.4% (95% CI 78.2–99.2%) and a specificity of 98.5% (95% CI 92.0–99.7%). Thus, osteocalcin could be used in the diagnostic testing for endogenous hypercortisolism in patients referred to exclude CS and to identify CS among patients of postmenopausal age with osteoporosis. PMID:27347399
McMorrow, Meredith L.; Masanja, M. Irene; Abdulla, Salim M. K.; Kahigwa, Elizeus; Kachur, S. Patrick
2018-01-01
Rapid diagnostic tests (RDTs) represent an alternative to microscopy for malaria diagnosis and have shown high sensitivity and specificity in a variety of study settings. Current World Health Organization (WHO) guidelines for quality control of RDTs provide detailed instructions on pre-field testing, but offer little guidance for quality assurance once RDTs are deployed in health facilities. From September 2006 to April 2007, we introduced a histidine-rich protein II (HRP2)-based RDT (Paracheck) for suspected malaria cases five years of age and older in nine health facilities in Rufiji District, Tanzania, to assess sensitivity and specificity of RDTs in routine use at rural health facilities. Thick blood smears were collected for all patients tested with RDTs and stained and read by laboratory personnel in each facility. Thick smears were subsequently reviewed by a reference microscopist to determine RDT sensitivity and specificity. In all nine health facilities, there were significant problems with the quality of staining and microscopy. Sensitivity and specificity of RDTs were difficult to assess given the poor quality of routine blood smear staining. Mean operational sensitivity of RDTs based on reference microscopy was 64.8%, but varied greatly by health facility, range 18.8–85.9%. Sensitivity of RDTs increased with increasing parasite density. Specificity remained high at 87.8% despite relatively poor slide quality. Institution of quality control of RDTs based on poor quality blood smear staining may impede reliable measurement of sensitivity and specificity and undermine confidence in the new diagnostic. There is an urgent need for the development of alternative quality control procedures for rapid diagnostic tests that can be performed at the facility level. PMID:18784230
Shapiro, Adrienne E; Hong, Ting; Govere, Sabina; Thulare, Hilary; Moosa, Mahomed-Yunus; Dorasamy, Afton; Wallis, Carole L; Celum, Connie L; Grosset, Jacques; Drain, Paul K
2018-05-28
There is an urgent need for more accurate screening tests for tuberculosis(TB). We assessed the diagnostic accuracy of C-reactive protein (CRP) as a screening test for active TB in HIV-infected ambulatory adults. CRP levels were measured in blood collected at the time of HIV testing.Diagnostic accuracy of CRP for pulmonary TB was calculated (reference standard: TB culture), compared to the WHO 4-symptom screen, consisting of cough, fever, night sweats, and weight loss. Diagnostic accuracy was also calculated for CRP in a larger cohort of HIV-infected adults with a positive symptom screen (reference standard: clinical or microbiological TB). Among 425 HIV-infected outpatients systematically tested for pulmonary TB, TB culture was positive in 42 (10%), 279 (66%) had at least one TB-related symptom and 197 (46%) had a CRP >5 mg/L. The sensitivity of CRP and the TB symptom screen to detect TB was the same (90.5%; 95%CI 77.4-97.3) but specificity of CRP was higher than for the TB symptom screen (58.5% vs. 37.1%, p<0.001). Of persons with no symptoms and normal CRP, 99 (98%) had no TB. In another cohort of 749 patients presenting with at least one TB-related symptom and clinically evaluated, CRP had a sensitivity of 98.7% and specificity of 48.3%. In HIV-infected outpatients, CRP was as sensitive but substantially more specific than TB symptom screening. Use of CRP as a screening tool to exclude active TB could identify the same number of HIV-associated TB cases, but reduce the use of diagnostic sputum testing in TB-endemic regions.
Mansion-de Vries, Elisabeth Maria; Knorr, Nicole; Paduch, Jan-Hendrik; Zinke, Claudia; Hoedemaker, Martina; Krömker, Volker
2014-03-01
Clinical mastitis is one of the most common and expensive diseases of dairy cattle. To make an informed treatment decision, it is important to know the causative pathogen. However, no detection of bacterial growth can be made in approximately 30% of all clinical cases of mastitis. Before selecting the treatment regimen, it is important to know whether the mastitis-causing pathogen (MCP) is Gram-positive or Gram-negative. The aim of this field study was to investigate whether using two 3M Petrifilm™ products on-farm (which conveys a higher degree of sample freshness but also bears a higher risk for contamination than working in a lab) as 24-h rapid diagnostic of clinical mastitis achieved results that were comparable to the conventional microbiological diagnostic method. AerobicCount (AC)-Petrifilm™ and ColiformCount (CC)-Petrifilm™ were used to identify the total bacterial counts and Gram-negative bacteria in samples from clinical mastitis cases, respectively. Missing growth on both plates was classified as no bacterial detection. Growth only on the AC-Petrifilm™ was assessed as Gram-positive, and growth on both Petrifilm™ plates was assessed as Gram-negative bacterial growth. Additionally, milk samples were analysed by conventional microbiological diagnostic method on aesculin blood agar as a reference method. Overall, 616 samples from clinical mastitis cases were analysed. Using the reference method, Gram-positive and Gram-negative bacteria, mixed bacterial growth, contaminated samples and yeast were determined in 32.6%, 20.0%, 2.5%, 14.1% and 1.1% of the samples, respectively. In 29.7% of the samples, microbiological growth could not be identified. Using the Petrifilm™ concept, bacterial growth was detected in 59% of the culture-negative samples. The sensitivity of the Petrifilm™ for Gram-positive and Gram-negative MCP was 85.2% and 89.9%, respectively. The specificity was 75.4% for Gram-positive and 88.4% for Gram-negative MCP. For the culture-negative samples, sensitivity was 41.0% and specificity was 91.0%. The results indicate that the Petrifilm™ concept is suitable for therapeutic decision-making at the farm level or in veterinary practice. As this concept does not allow any statement about the genus or species of microorganisms, relevant MCP should be assessed periodically at the herd level with conventional microbiological diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.
Kosack, Cara S; Naing, Wint Thu; Piriou, Erwan; Shanks, Leslie
2013-05-21
Malaria rapid diagnostic tests (RDTs) are commonly used in Médecins Sans Frontières (MSF) programmes to detect acute malaria infection. Programmes in regions with both Plasmodium falciparum and non-falciparum malaria (i.e. Plasmodium ovale, Plasmodium malariae and Plasmodium vivax) use a three-band P. falciparum/Pan test such as the SD Bioline Malaria Ag P.f/Pan 05FK60 (Standard Diagnostics, Kyonggi, Republic of Korea), hereafter referred to as SD 05FK60, as used by the MSF-Holland clinics in Rakhine state, Myanmar. In spite of published reports of generally good test performance, medical and paramedical staff on the ground often doubt the diagnostic accuracy of these RDTs. Parallel testing with malaria microscopy and RDT was conducted at two clinics in Rakhine state, Myanmar, for a period of 14 months as a programmatic response due to doubts and concerns of medical and paramedical staff into malaria RDTs. A total of 2,585 blood samples from non-pregnant suspected malaria patients were examined by the SD 05FK60 RDT and microscopy at two clinics in Myanmar from October 2010 to December 2011. The reference standard microscopy diagnosed 531 P. falciparum and 587 P. vivax or P. malariae mono-infections. The overall sensitivity for P. falciparum detection by the SD 05FK60 was 90.2% (95% CI: 87.4-92.6) and for P. vivax/P. malariae 79.4% (95% CI: 75.9-82.6). The overall specificity for P. falciparum detection by the SD 05FK60 was 98.5% (95% CI: 97.7-99.1) and for P. vivax/P. malariae 98.7% (95% CI: 97.9-99.2). The sensitivity for P. falciparum was >91% for parasitaemia levels of >100-1,000 parasites/μl and increased for P. vivax/P. malariae with the parasitaemia level but was overall lower than for P. falciparum 25/408 and 13/420 cases, respectively, of P. falciparum and non-falciparum malaria were missed by the RDT. In field conditions in Myanmar, the SD 05FK60 malaria RDT performed consistent with other reports. The test detected malaria caused by P. vivax/P. malariae to a lesser extent than P. falciparum infection. Sensitivity improved with increasing parasitaemia level, however even at higher levels some infections were missed. The SD 05FK60 is adequate for use in settings where high quality microscopy is not available.
Britton, Sumudu; Cheng, Qin; McCarthy, James S
2016-02-16
As malaria transmission continues to decrease, an increasing number of countries will enter pre-elimination and elimination. To interrupt transmission, changes in control strategies are likely to require more accurate identification of all carriers of Plasmodium parasites, both symptomatic and asymptomatic, using diagnostic tools that are highly sensitive, high throughput and with fast turnaround times preferably performed in local health service settings. Currently available immunochromatographic lateral flow rapid diagnostic tests and field microscopy are unlikely to consistently detect infections at parasite densities less than 100 parasites/µL making them insufficiently sensitive for detecting all carriers. Molecular diagnostic platforms, such as PCR and LAMP, are currently available in reference laboratories, but at a cost both financially and in turnaround time. This review describes the recent progress in developing molecular diagnostic tools in terms of their capacity for high throughput and potential for performance in non-reference laboratories for malaria elimination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ubeda, Carlos, E-mail: cubeda@uta.cl; Miranda, Patricia; Vano, Eliseo
Purpose: To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Methods: Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-areamore » product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Results: Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm{sup 2} for <1 yr; 1.74 and 1.90 Gy cm{sup 2} for 1 to <5 yr; 2.83 and 3.22 Gy cm{sup 2} for 5 to <10 yr; and 7.34 and 8.68 Gy cm{sup 2} for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm{sup 2}/kg) for diagnostic and therapeutic procedures. Conclusions: The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate.« less
Ubeda, Carlos; Miranda, Patricia; Vano, Eliseo
2015-02-01
To present the results of a patient dose evaluation program in pediatric cardiology and propose local diagnostic reference levels (DRLs) for different types of procedure and age range, in addition to suggesting approaches to correlate patient dose values with patient weight. This study was the first conducted in Latin America for pediatric interventional cardiology under the auspices of the International Atomic Energy Agency. Over three years, the following data regarding demographic and patient dose values were collected: age, gender, weight, height, number of cine series, total number of cine frames, fluoroscopy time (FT), and two dosimetric quantities, dose-area product (DAP) and cumulative dose (CD), at the patient entrance reference point. The third quartile values for FT, DAP, CD, number of cine series, and the DAP/body weight ratio were proposed as the set of quantities to use as local DRLs. Five hundred and seventeen patients were divided into four age groups. Sample sizes by age group were 120 for <1 yr; 213 for 1 to <5 yr; 82 for 5 to <10 yr; and 102 for 10 to <16 yr. The third quartile values obtained for DAP by diagnostic and therapeutic procedures and age range were 1.17 and 1.11 Gy cm 2 for <1 yr; 1.74 and 1.90 Gy cm 2 for 1 to <5 yr; 2.83 and 3.22 Gy cm 2 for 5 to <10 yr; and 7.34 and 8.68 Gy cm 2 for 10 to <16 yr, respectively. The third quartile value obtained for the DAP/body weight ratio for the full sample of procedures was 0.17 (Gy cm 2 /kg) for diagnostic and therapeutic procedures. The data presented in this paper are an initial attempt at establishing local DRLs in pediatric interventional cardiology, from a large sample of procedures for the standard age bands used in Europe, complemented with the values of the ratio between DAP and patient weight. This permits a rough estimate of DRLs for different patient weights and the refining of these values for the age bands when there may be large differences in child size. These DRLs were obtained at the largest pediatric hospital in Chile, with an active optimization program, and could be used by other hospitals in the Latin America region to compare their current patient dose values and determine whether corrective action is appropriate. © 2015 American Association of Physicists in Medicine.
RADIOISOTOPES IN MEDICINE AND HUMAN PHYSIOLOGY. A Selected List of References
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCormick, J.A. comp.
1958-08-01
This bibliography contains 2862 references on uses of radioisotopes in diagnostic medicine, therapeutic medicine, clinical research, human physiology, general medical research, and immunology. The references were taken from the 1948 to 1956 open literature. A list of the journals from which the references were selected and an author index are included. (auth)'
Translation and Validation of the Knee Society Score - KSS for Brazilian Portuguese
Silva, Adriana Lucia Pastore e; Demange, Marco Kawamura; Gobbi, Riccardo Gomes; da Silva, Tânia Fernanda Cardoso; Pécora, José Ricardo; Croci, Alberto Tesconi
2012-01-01
Objective To translate, culturally adapt and validate the "Knee Society Score"(KSS) for the Portuguese language and determine its measurement properties, reproducibility and validity. Methods We analyzed 70 patients of both sexes, aged between 55 and 85 years, in a cross-sectional clinical trial, with diagnosis of primary osteoarthritis ,undergoing total knee arthroplasty surgery. We assessed the patients with the English version of the KSS questionnaire and after 30 minutes with the Portuguese version of the KSS questionnaire, done by a different evaluator. All the patients were assessed preoperatively, and again at three, and six months postoperatively. Results There was no statistical difference, using Cronbach's alpha index and the Bland-Altman graphical analysis, for the knees core during the preoperative period (p =1), and at three months (p =0.991) and six months postoperatively (p =0.985). There was no statistical difference for knee function score for all three periods (p =1.0). Conclusion The Brazilian version of the Knee Society Score is easy to apply, as well providing as a valid and reliable instrument for measuring the knee score and function of Brazilian patients undergoing TKA. Level of Evidence: Level I - Diagnostic Studies- Investigating a Diagnostic Test- Testing of previously developed diagnostic criteria on consecutive patients (with universally applied 'gold' reference standard). PMID:24453576
21 CFR 660.25 - Potency tests without reference preparations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...
21 CFR 660.25 - Potency tests without reference preparations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...
21 CFR 660.25 - Potency tests without reference preparations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...
21 CFR 660.25 - Potency tests without reference preparations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...
21 CFR 660.25 - Potency tests without reference preparations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...
DATAS Hardware Diagnostic Tests
DOT National Transportation Integrated Search
1990-10-01
This document is reference material for personnel using the Data Link and : Analysis System (DATAS) for hardware diagnostic testing. Included in this : document is a brief overall description of the DATAS, and a thorough : description of how to opera...
How Should DSM-V Criteria for Schizophrenia Include Cognitive Impairment?
Keefe, Richard S. E.; Fenton, Wayne S.
2007-01-01
Neurocognitive impairment is considered a core component of schizophrenia and is increasingly under investigation as a potential treatment target. On average, cognitive impairment is severe to moderately severe compared with healthy controls, and almost all patients with schizophrenia demonstrate cognitive decrements compared with their expected level if they had not developed the illness. Compared with patients with affective disorders, cognitive impairment in schizophrenia appears earlier, is more severe, and tends to be more independent of clinical symptoms. While the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision, description of schizophrenia includes several references to cognitive impairment, neither the diagnostic criteria nor the subtypology of schizophrenia include a requirement of cognitive impairment. We forward for consideration a proposal that the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition, criteria include a specific criterion of “a level of cognitive functioning suggesting a consistent severe impairment and/or a significant decline from premorbid levels considering the patient's educational, familial, and socioeconomic background.” The inclusion of this criterion may increase the “point of rarity” with affective psychoses and may increase clinicians' awareness of cognitive impairment, potentially leading to more accurate prognosis and better treatment outcomes. Future research will need to address the validity of these possibilities. The reliable determination of cognitive impairment as part of a standard diagnostic evaluation may present challenges to diagnosticians with limited resources or insufficient expertise. Various cognitive assessment methods for clinicians, including brief assessments and interview-based assessments, are discussed. Given the current emphasis on the development of cognitive treatments, the evaluation of cognition in schizophrenia is an essential component of mental health education. PMID:17567627
2012-01-01
Background Early diagnosis, as well as prompt and effective treatment of uncomplicated malaria, are essential components of the anti-malaria strategy in Madagascar to prevent severe malaria, reduce mortality and limit malaria transmission. The purpose of this study was to assess the performance of the malaria rapid diagnostic tests (RDTs) used by community health workers (CHWs) by comparing RDT results with two reference methods (microscopy and Polymerase Chain Reaction, PCR). Methods Eight CHWs in two districts, each with a different level of endemic malaria transmission, were trained to use RDTs in the management of febrile children under five years of age. RDTs were performed by CHWs in all febrile children who consulted for fever. In parallel, retrospective parasitological diagnoses were made by microscopy and PCR. The results of these different diagnostic methods were analysed to evaluate the diagnostic performance of the RDTs administered by the CHWs. The stability of the RDTs stored by CHWs was also evaluated. Results Among 190 febrile children with suspected malaria who visited CHWs between February 2009 and February 2010, 89.5% were found to be positive for malaria parasites by PCR, 51.6% were positive by microscopy and 55.8% were positive by RDT. The performance accuracy of the RDTs used by CHWs in terms of sensitivity, specificity, positive and negative predictive values was greater than 85%. Concordance between microscopy and RDT, estimated by the Kappa value was 0.83 (95% CI: 0.75-0.91). RDTs stored by CHWs for 24 months were capable of detecting Plasmodium falciparum in blood at a level of 200 parasites/μl. Conclusion Introduction of easy-to-use diagnostic tools, such as RDTs, at the community level appears to be an effective strategy for improving febrile patient management and for reducing excessive use of anti-malarial drugs. PMID:22443344
Ratsimbasoa, Arsène; Ravony, Harintsoa; Vonimpaisomihanta, Jeanne-Aimée; Raherinjafy, Rogelin; Jahevitra, Martial; Rapelanoro, Rabenja; Rakotomanga, Jean De Dieu Marie; Malvy, Denis; Millet, Pascal; Ménard, Didier
2012-03-25
Early diagnosis, as well as prompt and effective treatment of uncomplicated malaria, are essential components of the anti-malaria strategy in Madagascar to prevent severe malaria, reduce mortality and limit malaria transmission. The purpose of this study was to assess the performance of the malaria rapid diagnostic tests (RDTs) used by community health workers (CHWs) by comparing RDT results with two reference methods (microscopy and Polymerase Chain Reaction, PCR). Eight CHWs in two districts, each with a different level of endemic malaria transmission, were trained to use RDTs in the management of febrile children under five years of age. RDTs were performed by CHWs in all febrile children who consulted for fever. In parallel, retrospective parasitological diagnoses were made by microscopy and PCR. The results of these different diagnostic methods were analysed to evaluate the diagnostic performance of the RDTs administered by the CHWs. The stability of the RDTs stored by CHWs was also evaluated. Among 190 febrile children with suspected malaria who visited CHWs between February 2009 and February 2010, 89.5% were found to be positive for malaria parasites by PCR, 51.6% were positive by microscopy and 55.8% were positive by RDT. The performance accuracy of the RDTs used by CHWs in terms of sensitivity, specificity, positive and negative predictive values was greater than 85%. Concordance between microscopy and RDT, estimated by the Kappa value was 0.83 (95% CI: 0.75-0.91). RDTs stored by CHWs for 24 months were capable of detecting Plasmodium falciparum in blood at a level of 200 parasites/μl. Introduction of easy-to-use diagnostic tools, such as RDTs, at the community level appears to be an effective strategy for improving febrile patient management and for reducing excessive use of anti-malarial drugs.
Mohr, Sharif B; Gorham, Edward D; Alcaraz, John E; Kane, Christopher I; Macera, Caroline A; Parsons, J Kellogg; Wingard, Deborah L; Horst, Ronald; Garland, Cedric F
2013-03-01
The objective of this study was to ascertain whether a relationship exists between pre-diagnostic serum levels of 25-hydroxyvitamin D (25(OH)D) and risk of breast cancer in young women. About 600 incident cases of breast cancer were matched to 600 controls as part of a nested case-control study that utilized pre-diagnostic sera. Logistic regression was used to assess the relationship between serum 25(OH)D concentration and breast cancer risk, controlling for race and age. According to the conditional logistic regression for all subjects, odds ratios for breast cancer by quintile of serum 25(OH)D from lowest to highest were 1.2, 1.0, 0.9, 1.1, and 1.0 (reference) (p trend = 0.72). After multivariate regression for subjects whose blood had been collected within 90 days preceding diagnosis, odds ratios for breast cancer by quintile of serum 25(OH)D from lowest to highest were 3.3, 1.9, 1.7, 2.6, and 1.0 (reference) (p trend = 0.09). An inverse association between serum 25(OH)D concentration and risk of breast cancer was not present in the principal analysis, although an inverse association was present in a small subgroup analysis of subjects whose blood had been collected within 90 days preceding diagnosis. Further prospective studies of 25(OH)D and breast cancer risk are needed.
An evaluation of Wikipedia as a resource for patient education in nephrology.
Thomas, Garry R; Eng, Lawson; de Wolff, Jacob F; Grover, Samir C
2013-01-01
Wikipedia, a multilingual online encyclopedia, is a common starting point for patient medical searches. As its articles can be authored and edited by anyone worldwide, the credibility of the medical content of Wikipedia has been openly questioned. Wikipedia medical articles have also been criticized as too advanced for the general public. This study assesses the comprehensiveness, reliability, and readability of nephrology articles on Wikipedia. The International Statistical Classification of Diseases and Related problems, 10th Edition (ICD-10) diagnostic codes for nephrology (N00-N29.8) were used as a topic list to investigate the English Wikipedia database. Comprehensiveness was assessed by the proportion of ICD-10 codes that had corresponding articles. Reliability was measured by both the number of references per article and proportion of references from substantiated sources. Finally, readability was assessed using three validated indices (Flesch-Kincaid grade level, Automated readability index, and Flesch reading ease). Nephrology articles on Wikipedia were relatively comprehensive, with 70.5% of ICD-10 codes being represented. The articles were fairly reliable, with 7.1 ± 9.8 (mean ± SD) references per article, of which 59.7 ± 35.0% were substantiated references. Finally, all three readability indices determined that nephrology articles are written at a college level. Wikipedia is a comprehensive and fairly reliable medical resource for nephrology patients that is written at a college reading level. Accessibility of this information for the general public may be improved by hosting it at alternative Wikipedias targeted at a lower reading level, such as the Simple English Wikipedia. © 2013 Wiley Periodicals, Inc.
Lombos, Ernesto; Tang, Elaine; Perusini, Stephen; Eshaghi, Alireza; Nagra, Sandeep; Frantz, Christine; Olsha, Romy; Kristjanson, Erik; Dimitrova, Kristina; Safronetz, David; Drebot, Mike
2017-01-01
ABSTRACT With the emerging Zika virus (ZIKV) epidemic, accessible real-time reverse transcription-PCR (rRT-PCR) assays are needed to streamline testing. The commercial Altona Diagnostics RealStar ZIKV rRT-PCR test kit (Altona PCR) has been approved for emergency use authorization by the U.S. FDA. Our aim was to verify the Altona PCR by comparing it to the CDC-designed dual-target ZIKV rRT-PCR reference assay (reference PCR) and describe the demographics of patients tested for ZIKV by rRT-PCR in Ontario, Canada. A large set of clinical specimens was tested for ZIKV by the Altona PCR and the reference PCR. Positive or equivocal specimens underwent PCR and Sanger sequencing targeting the ZIKV NS5 gene. A total of 671 serum specimens were tested by the reference PCR: 58 (8.6%) were positive, 193 (28.8%) were equivocal, and 420 (62.6%) were negative. Ninety percent of the reference PCR-positive patients were tested in the first 5 days after symptom onset. The Altona PCR was performed on 284/671 specimens tested by the reference PCR. The Altona PCR was positive for 53/58 (91%) reference PCR-positive specimens and 16/193 (8%) reference PCR-equivocal specimens; the ZIKV NS5 PCR was positive for all 68 Altona PCR-positive specimens and negative for all 181 Altona PCR-negative specimens that underwent the NS5 PCR. The Altona PCR has very good sensitivity (91%) and specificity (97%) compared to the reference PCR. The Altona PCR can be used for ZIKV diagnostic testing and has less extensive verification requirements than a laboratory-developed test. PMID:28298448
Amylase in drain fluid for the diagnosis of pancreatic leak in post-pancreatic resection.
Davidson, Tsetsegdemberel Bat-Ulzii; Yaghoobi, Mohammad; Davidson, Brian R; Gurusamy, Kurinchi Selvan
2017-04-07
The treatment of people with clinically significant postoperative pancreatic leaks is different from those without clinically significant pancreatic leaks. It is important to know the diagnostic accuracy of drain fluid amylase as a triage test for the detection of clinically significant pancreatic leaks, so that an informed decision can be made as to whether the patient with a suspected pancreatic leak needs further investigations and treatment. There is currently no systematic review of the diagnostic test accuracy of drain fluid amylase for the diagnosis of clinically relevant pancreatic leak. To determine the diagnostic accuracy of amylase in drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection. We searched MEDLINE, Embase, the Science Citation Index Expanded, and the National Institute for Health Research Health Technology Assessment (NIHR HTA) websites up to 20 February 2017. We searched the references of the included studies to identify additional studies. We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We also performed a 'related search' and 'citing reference' search in MEDLINE and Embase. We included all studies that evaluated the diagnostic test accuracy of amylase in the drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection excluding total pancreatectomy. We planned to exclude case-control studies because these studies are prone to bias, but did not find any. At least two authors independently searched and screened the references produced by the search to identify relevant studies. Two review authors independently extracted data from the included studies. The included studies reported drain fluid amylase on different postoperative days and measured at different cut-off levels, so it was not possible to perform a meta-analysis using the bivariate model as planned. We have reported the sensitivity, specificity, post-test probability of a positive and negative drain fluid amylase along with 95% confidence interval (CI) on each of the different postoperative days and measured at different cut-off levels. A total of five studies including 868 participants met the inclusion criteria for this review. The five studies included in this review reported the value of drain fluid amylase at different thresholds and different postoperative days. The sensitivities and specificities were variable; the sensitivities ranged between 0.72 and 1.00 while the specificities ranged between 0.73 and 0.99 for different thresholds on different postoperative days. At the median prevalence (pre-test probability) of 15.9%, the post-test probabilities for pancreatic leak ranged between 35.9% and 95.4% for a positive drain fluid amylase test and ranged between 0% and 5.5% for a negative drain fluid amylase test.None of the studies used the reference standard of confirmation by surgery or by a combination of surgery and clinical follow-up, but used the International Study Group on Pancreatic Fistula (ISGPF) grade B and C as the reference standard. The overall methodological quality was unclear or high in all the studies. Because of the paucity of data and methodological deficiencies in the studies, we are uncertain whether drain fluid amylase should be used as a method for testing for pancreatic leak in an unselected population after pancreatic resection; and we judge that the optimal cut-off of drain fluid amylase for making the diagnosis of pancreatic leak is also not clear. Further well-designed diagnostic test accuracy studies with pre-specified index test threshold of drain fluid amylase (at three times more on postoperative day 5 or another suitable pre-specified threshold), appropriate follow-up (for at least six to eight weeks to ensure that there are no pancreatic leaks), and clearly defined reference standards (of surgical, clinical, and radiological confirmation of pancreatic leak) are important to reliably determine the diagnostic accuracy of drain fluid amylase in the diagnosis of pancreatic leak.
Wang, Haili; Tso, Victor; Wong, Clarence; Sadowski, Dan; Fedorak, Richard N
2014-03-20
Adenomatous polyps are precursors of colorectal cancer; their detection and removal is the goal of colon cancer screening programs. However, fecal-based methods identify patients with adenomatous polyps with low levels of sensitivity. The aim or this study was to develop a highly accurate, prototypic, proof-of-concept, spot urine-based diagnostic test using metabolomic technology to distinguish persons with adenomatous polyps from those without polyps. Prospective urine and stool samples were collected from 876 participants undergoing colonoscopy examination in a colon cancer screening program, from April 2008 to October 2009 at the University of Alberta. Colonoscopy reference standard identified 633 participants with no colonic polyps and 243 with colonic adenomatous polyps. One-dimensional nuclear magnetic resonance spectra of urine metabolites were analyzed to define a diagnostic metabolomic profile for colonic adenomas. A urine metabolomic diagnostic test for colonic adenomatous polyps was established using 67% of the samples (un-blinded training set) and validated using the other 33% of the samples (blinded testing set). The urine metabolomic diagnostic test's specificity and sensitivity were compared with those of fecal-based tests. Using a two-component, orthogonal, partial least-squares model of the metabolomic profile, the un-blinded training set identified patients with colonic adenomatous polyps with 88.9% sensitivity and 50.2% specificity. Validation using the blinded testing set confirmed sensitivity and specificity values of 82.7% and 51.2%, respectively. Sensitivities of fecal-based tests to identify colonic adenomas ranged from 2.5 to 11.9%. We describe a proof-of-concept spot urine-based metabolomic diagnostic test that identifies patients with colonic adenomatous polyps with a greater level of sensitivity (83%) than fecal-based tests.
Protein electrophoresis as a diagnostic and prognostic tool in raptor medicine.
Tatum, L M; Zaias, J; Mealey, B K; Cray, C; Bossart, G D
2000-12-01
Plasma proteins of 139 healthy adult birds of prey from 10 species were separated by electrophoresis to characterize and document normal reference ranges and species-specific electrophoretic patternsand to evaluate the value of this technique for health screening, disease diagnosis, and prognostic indication. Species studied included bald eagle (Haliaeetus leucocephalus), red-tailed hawk (Buteo jamaicensis), barn owl (Tyto alba), great horned owl (Bubo virginianus), turkey vulture (Cathartes aura), Harris' hawk (Parabuteo unicinctus), Stellar's sea eagle (Haliaeetus pelagicus), barred owl (Strix varia), screech owl (Otus asio), and black vulture (Coragyps atratus). Several clinical cases show the diagnostic/therapeutic value of protein electrophoresis in raptors. This study establishes species-specific reference ranges for several birds of prey and discusses the benefit of electrophoresis as a diagnostic technique in health screens, as a diagnostic aid in conjunction with other tests, and as a prognostic indicator in clinical evaluation of raptors.
Moseholm, Ellen; Rydahl-Hansen, Susan; Lindhardt, Bjarne Ørskov
2016-01-01
Aim Undergoing diagnostic evaluation for possible cancer can affect health-related quality of life (HRQoL). The aims of this study were to examine the HRQoL in patients undergoing a diagnostic evaluation for possible cancer due to non-specific symptoms and further to investigate the impact of socio-demographic and medical factors associated with HRQoL at the time of diagnosis. Methods This was a prospective, multicenter survey study that included patients who were referred for a diagnostic evaluation due to non-specific cancer symptoms. Participants completed the EORTC-QLQ-C30 quality of life scale before and after completing the diagnostic evaluation. The baseline and follow-up EORTC-QLQ-C30 scores were compared with reference populations. The impact of socio-demographic and medical factors on HRQoL at follow-up was explored by bootstrapped multivariate linear regression. Results A total of 838 patients participated in the study; 680 (81%) also completed follow-up. Twenty-two percent of the patients received a cancer diagnosis at the end of follow-up. Patients presented initially with a high burden of symptoms, less role and emotional functioning and a lower global health/QoL. Most domains improved after diagnosis and no clinically important difference between baseline and follow-up scores was found. Patients reported effects on HRQoL both at baseline and at follow-up compared with the Danish reference population and had similar scores as a cancer reference population. Co-morbidity, being unemployed and receiving a cancer diagnosis had the greatest effect on HRQoL around the time of diagnosis. Conclusions Patients with non-specific symptoms reported an affected HRQoL while undergoing a diagnostic evaluation for possible cancer. Morbidity, being unemployed and receiving a cancer diagnosis had the greatest effect on HRQoL around the time of diagnosis. PMID:26840866
GENE-07. MOLECULAR NEUROPATHOLOGY 2.0 - INCREASING DIAGNOSTIC ACCURACY IN PEDIATRIC NEUROONCOLOGY
Sturm, Dominik; Jones, David T.W.; Capper, David; Sahm, Felix; von Deimling, Andreas; Rutkoswki, Stefan; Warmuth-Metz, Monika; Bison, Brigitte; Gessi, Marco; Pietsch, Torsten; Pfister, Stefan M.
2017-01-01
Abstract The classification of central nervous system (CNS) tumors into clinically and biologically distinct entities and subgroups is challenging. Children and adolescents can be affected by >100 histological variants with very variable outcomes, some of which are exceedingly rare. The current WHO classification has introduced a number of novel molecular markers to aid routine neuropathological diagnostics, and DNA methylation profiling is emerging as a powerful tool to distinguish CNS tumor classes. The Molecular Neuropathology 2.0 study aims to integrate genome wide (epi-)genetic diagnostics with reference neuropathological assessment for all newly-diagnosed pediatric brain tumors in Germany. To date, >350 patients have been enrolled. A molecular diagnosis is established by epigenetic tumor classification through DNA methylation profiling and targeted panel sequencing of >130 genes to detect diagnostically and/or therapeutically useful DNA mutations, structural alterations, and fusion events. Results are aligned with the reference neuropathological diagnosis, and discrepant findings are discussed in a multi-disciplinary tumor board including reference neuroradiological evaluation. Ten FFPE sections as input material are sufficient to establish a molecular diagnosis in >95% of tumors. Alignment with reference pathology results in four broad categories: a) concordant classification (~77%), b) discrepant classification resolvable by tumor board discussion and/or additional data (~5%), c) discrepant classification without currently available options to resolve (~8%), and d) cases currently unclassifiable by molecular diagnostics (~10%). Discrepancies are enriched in certain histopathological entities, such as histological high grade gliomas with a molecularly low grade profile. Gene panel sequencing reveals predisposing germline events in ~10% of patients. Genome wide (epi-)genetic analyses add a valuable layer of information to routine neuropathological diagnostics. Our study provides insight into CNS tumors with divergent histopathological and molecular classification, opening new avenues for research discoveries and facilitating optimization of clinical management for affected patients in the future.
Harr, K.E.; Harvey, J.W.; Bonde, R.K.; Murphy, D.; Lowe, Mark; Menchaca, M.; Haubold, E.M.; Francis-Floyd, R.
2006-01-01
Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as “cold stress syndrome” and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha1 acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10–50 μg/ml with an equivocal interval of 51–70 μg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7–1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4–2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100–400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.
Moseholm, Ellen; Rydahl-Hansen, Susan; Lindhardt, Bjarne Ørskov
2016-01-01
Undergoing diagnostic evaluation for possible cancer can affect health-related quality of life (HRQoL). The aims of this study were to examine the HRQoL in patients undergoing a diagnostic evaluation for possible cancer due to non-specific symptoms and further to investigate the impact of socio-demographic and medical factors associated with HRQoL at the time of diagnosis. This was a prospective, multicenter survey study that included patients who were referred for a diagnostic evaluation due to non-specific cancer symptoms. Participants completed the EORTC-QLQ-C30 quality of life scale before and after completing the diagnostic evaluation. The baseline and follow-up EORTC-QLQ-C30 scores were compared with reference populations. The impact of socio-demographic and medical factors on HRQoL at follow-up was explored by bootstrapped multivariate linear regression. A total of 838 patients participated in the study; 680 (81%) also completed follow-up. Twenty-two percent of the patients received a cancer diagnosis at the end of follow-up. Patients presented initially with a high burden of symptoms, less role and emotional functioning and a lower global health/QoL. Most domains improved after diagnosis and no clinically important difference between baseline and follow-up scores was found. Patients reported effects on HRQoL both at baseline and at follow-up compared with the Danish reference population and had similar scores as a cancer reference population. Co-morbidity, being unemployed and receiving a cancer diagnosis had the greatest effect on HRQoL around the time of diagnosis. Patients with non-specific symptoms reported an affected HRQoL while undergoing a diagnostic evaluation for possible cancer. Morbidity, being unemployed and receiving a cancer diagnosis had the greatest effect on HRQoL around the time of diagnosis.
Harr, Kendal; Harvey, John; Bonde, Robert; Murphy, David; Lowe, Mark; Menchaca, Maya; Haubold, Elsa; Francis-Floyd, Ruth
2006-06-01
Manatees (Trichechus manatus latirostris) are afflicted with inflammatory and infectious disease secondary to human interaction, such as boat strike and entanglement, as well as "cold stress syndrome" and pneumonia. White-blood-cell count and fever, primary indicators of systemic inflammation in most species, are insensitive in diagnosing inflammatory disease in manatees. Acute phase-response proteins, such as haptoglobin and serum amyloid A, have proven to be sensitive measures of inflammation/infection in domestic large animal species. This study assessed diagnosis of generalized inflammatory disease by different methods including total white-blood-cell count, albumin: globulin ratio, gel electrophoresis analysis, C-reactive protein, alpha, acid glycoprotein, haptoglobin, fibrinogen, and serum amyloid A. Samples were collected from 71 apparently healthy and 27 diseased animals during diagnostic medical examination. Serum amyloid A, measured by ELISA, followed by albumin:globulin ratio, measured by plasma gel electrophoresis, were most sensitive in diagnosing inflammatory disease, with diagnostic sensitivity and specificity of approximately 90%. The reference interval for serum amyloid A is <10-50 microg/ml with an equivocal interval of 51-70 microg/ml. The reference interval for albumin:globulin ratio by plasma gel electrophoresis is 0.7-1.1. Albumin: globulin ratio, calculated using biochemical techniques, was not accurate due to overestimation of albumin by bromcresol green dye-binding methodology. Albumin:globulin ratio, measured by serum gel electrophoresis, has a low sensitivity of 15% due to the lack of fibrinogen in the sample. Haptoglobin, measured by hemoglobin titration, had a reference interval of 0.4-2.4 mg/ml, a diagnostic sensitivity of 60%, and a diagnostic specificity of 93%. The haptoglobin assay is significantly affected by hemolysis. Fibrinogen, measured by heat precipitation, has a reference interval of 100-400 mg/dl, a diagnostic sensitivity of 40%, and a diagnostic specificity of 95%.
Michelessi, Manuele; Lucenteforte, Ersilia; Miele, Alba; Oddone, Francesco; Crescioli, Giada; Fameli, Valeria; Korevaar, Daniël A; Virgili, Gianni
2017-01-01
Research has shown a modest adherence of diagnostic test accuracy (DTA) studies in glaucoma to the Standards for Reporting of Diagnostic Accuracy Studies (STARD). We have applied the updated 30-item STARD 2015 checklist to a set of studies included in a Cochrane DTA systematic review of imaging tools for diagnosing manifest glaucoma. Three pairs of reviewers, including one senior reviewer who assessed all studies, independently checked the adherence of each study to STARD 2015. Adherence was analyzed on an individual-item basis. Logistic regression was used to evaluate the effect of publication year and impact factor on adherence. We included 106 DTA studies, published between 2003-2014 in journals with a median impact factor of 2.6. Overall adherence was 54.1% for 3,286 individual rating across 31 items, with a mean of 16.8 (SD: 3.1; range 8-23) items per study. Large variability in adherence to reporting standards was detected across individual STARD 2015 items, ranging from 0 to 100%. Nine items (1: identification as diagnostic accuracy study in title/abstract; 6: eligibility criteria; 10: index test (a) and reference standard (b) definition; 12: cut-off definitions for index test (a) and reference standard (b); 14: estimation of diagnostic accuracy measures; 21a: severity spectrum of diseased; 23: cross-tabulation of the index and reference standard results) were adequately reported in more than 90% of the studies. Conversely, 10 items (3: scientific and clinical background of the index test; 11: rationale for the reference standard; 13b: blinding of index test results; 17: analyses of variability; 18; sample size calculation; 19: study flow diagram; 20: baseline characteristics of participants; 28: registration number and registry; 29: availability of study protocol; 30: sources of funding) were adequately reported in less than 30% of the studies. Only four items showed a statistically significant improvement over time: missing data (16), baseline characteristics of participants (20), estimates of diagnostic accuracy (24) and sources of funding (30). Adherence to STARD 2015 among DTA studies in glaucoma research is incomplete, and only modestly increasing over time.
Ekawati, Lenny L; Herdiana, Herdiana; Sumiwi, Maria E; Barussanah, Cut; Ainun, Cut; Sabri, Sabri; Maulana, Teuku; Rahmadyani, Rahmadyani; Maneh, Cut; Yani, Muhammad; Valenti, Paola; Elyazar, Iqbal R F; Hawley, William A
2015-06-11
The Health Office of Aceh aims to eliminate malaria from Aceh Province, Indonesia by 2015. Malaria was formerly common in Aceh (population 4.5 million), but has declined dramatically in recent years consequent to post-tsunami control efforts. Successful elimination will depend upon rapid and accurate diagnosis and case follow-up at community level. A prerequisite to this is widespread coverage of high quality malaria diagnosis. This study describes the results of a comprehensive assessment of the malaria diagnostic capacity in Aceh as the province moves towards malaria elimination. The study was conducted in 23 districts in Aceh from October 2010 to July 2011. Six types of questionnaires were used to collect data on competency of microscopists and laboratory capacity. Standardized slides were used to evaluate the proficiency of all microscopists. In addition, site visits to 17 primary health centres (PHC) assessed diagnostic practice and logistics capacity. Five hundred and seventy four malaria microscopists have been officially registered and assigned to duty in the 23 districts in Aceh Province. They work in 345 laboratories, predominantly in PHCs (69 %) and hospitals (25 %). Three laboratories were evaluated as adequate for all 30 elements, while 29 laboratories were adequate for less than five of 30 elements. Standardized proficiency tests showed that 413 microscopists were at basic (in training) level, with 10 advanced and 9 reference level. No microscopist achieved expert level. Neither the province nor any of Aceh's districts has a standardized inventory and logistics database for malaria diagnostics, nor did any of the surveyed laboratories operate a quality assurance programme for either microscopy or rapid diagnostic tests. The study highlights the importance of careful assessment of diagnostic capacity when embarking upon a large-scale malaria elimination programme. Aceh's laboratories have minimal infrastructure with nearly all microscopists still in training. On the positive side, a large workforce of microscopists has been assigned to laboratories with the needed equipment. Aceh will need to embark on a large-scale comprehensive quality assurance scheme if it is to achieve malaria elimination.
Establishment of local diagnostic reference levels for quality control in intraoral radiography.
Izawa, Maki; Harata, Yasuo; Shiba, Noriyoshi; Koizumi, Nobuhide; Ozawa, Tomonori; Takahashi, Nobutoshi; Okumura, Yasuhiko
2017-01-01
To investigate the dosage and imaging conditions for patients undergoing intraoral radiography at Meikai University Hospital and establish assurance and quality control data. Tube voltage, exposure time, and air kinetic energy released per unit mass (air kerma) of three intraoral radiography units were measured. To calculate the patient entrance dose (PED) for each radiograph using Insight film, we extracted data for 1063 patients from their exposure records. The PED was compared with the diagnostic reference level (DRL) from the European Commission and the UK. The tube voltage of the three units was maintained at 60 ± 2 kV. Differences in exposure time were less than 1.7 % for all units. The air kerma rates were well maintained within a 4.2 % error. Based on the patient data, there were no significant differences in the mean exposure times for males and females for all anatomical sites. The mean PED ranged from 1.09 ± 0.31 mGy for the mandibular incisors to 2.42 ± 0.33 mGy for the maxillary molars. The mean PED at the mandibular molars using InSight film was 1.59 ± 0.20 mGy, being less than the recommended value based on the DRL for intraoral radiography in the UK. We concluded that radiographic conditions at the hospital have been properly maintained. This basic quality control data may assist other dental radiation facilities to reduce patient dosage.
Buechi, Rahel; Faes, Livia; Bachmann, Lucas M; Thiel, Michael A; Bodmer, Nicolas S; Schmid, Martin K; Job, Oliver; Lienhard, Kenny R
2017-01-01
Objective The number of mobile applications addressing health topics is increasing. Whether these apps underwent scientific evaluation is unclear. We comprehensively assessed papers investigating the diagnostic value of available diagnostic health applications using inbuilt smartphone sensors. Methods Systematic Review—MEDLINE, Scopus, Web of Science inclusive Medical Informatics and Business Source Premier (by citation of reference) were searched from inception until 15 December 2016. Checking of reference lists of review articles and of included articles complemented electronic searches. We included all studies investigating a health application that used inbuilt sensors of a smartphone for diagnosis of disease. The methodological quality of 11 studies used in an exploratory meta-analysis was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool and the reporting quality with the ’STAndards for the Reporting of Diagnostic accuracy studies' (STARD) statement. Sensitivity and specificity of studies reporting two-by-two tables were calculated and summarised. Results We screened 3296 references for eligibility. Eleven studies, most of them assessing melanoma screening apps, reported 17 two-by-two tables. Quality assessment revealed high risk of bias in all studies. Included papers studied 1048 subjects (758 with the target conditions and 290 healthy volunteers). Overall, the summary estimate for sensitivity was 0.82 (95 % CI 0.56 to 0.94) and 0.89 (95 %CI 0.70 to 0.97) for specificity. Conclusions The diagnostic evidence of available health apps on Apple’s and Google’s app stores is scarce. Consumers and healthcare professionals should be aware of this when using or recommending them. PROSPERO registration number 42016033049. PMID:29247099
Hwang, Jee-In; Cimino, James J; Bakken, Suzanne
2003-01-01
The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED. The authors dissected nursing diagnostic terms from two source terminologies (Home Health Care Classification and the Omaha System) into the semantic categories of the ISO model. Consistent with the ISO model, they selected Focus and Judgment as required semantic categories for creating intensional definitions of nursing diagnostic concepts in the MED. Because the MED does not include Focus and Judgment hierarchies, the authors developed them to define the nursing diagnostic concepts. The ISO model was sufficient for dissecting the source terminologies into atomic terms. The authors identified 162 unique focus concepts from the 266 nursing diagnosis terms for inclusion in the Focus hierarchy. For the Judgment hierarchy, the authors precoordinated Judgment and Potentiality instead of using Potentiality as a qualifier of Judgment as in the ISO model. Impairment and Alteration were the most frequently occurring judgments. Nursing care represents a large proportion of health care activities; thus, it is vital that terms used by nurses are integrated into concept-oriented terminologies that provide broad coverage for the domain of health care. This study supports the utility of the ISO Reference Terminology Model for Nursing Diagnoses as a facilitator for the integration process.
Hwang, Jee-In; Cimino, James J.; Bakken, Suzanne
2003-01-01
Objective: The purposes of the study were (1) to evaluate the usefulness of the International Standards Organization (ISO) Reference Terminology Model for Nursing Diagnoses as a terminology model for defining nursing diagnostic concepts in the Medical Entities Dictionary (MED) and (2) to create the additional hierarchical structures required for integration of nursing diagnostic concepts into the MED. Design and Measurements: The authors dissected nursing diagnostic terms from two source terminologies (Home Health Care Classification and the Omaha System) into the semantic categories of the ISO model. Consistent with the ISO model, they selected Focus and Judgment as required semantic categories for creating intensional definitions of nursing diagnostic concepts in the MED. Because the MED does not include Focus and Judgment hierarchies, the authors developed them to define the nursing diagnostic concepts. Results: The ISO model was sufficient for dissecting the source terminologies into atomic terms. The authors identified 162 unique focus concepts from the 266 nursing diagnosis terms for inclusion in the Focus hierarchy. For the Judgment hierarchy, the authors precoordinated Judgment and Potentiality instead of using Potentiality as a qualifier of Judgment as in the ISO model. Impairment and Alteration were the most frequently occurring judgments. Conclusions: Nursing care represents a large proportion of health care activities; thus, it is vital that terms used by nurses are integrated into concept-oriented terminologies that provide broad coverage for the domain of health care. This study supports the utility of the ISO Reference Terminology Model for Nursing Diagnoses as a facilitator for the integration process. PMID:12668692
Customized Internal Reference Controls for Improved Assessment of Circulating MicroRNAs in Disease.
Schlosser, Kenny; McIntyre, Lauralyn A; White, R James; Stewart, Duncan J
2015-01-01
Altered levels of circulating extracellular miRNA in plasma and serum have shown promise as non-invasive biomarkers of disease. However, unlike the assessment of cellular miRNA levels for which there are accepted housekeeping genes, analogous reference controls for normalization of circulating miRNA are lacking. Here, we provide an approach to identify and validate circulating miRNA reference controls on a de novo basis, and demonstrate the advantages of these customized internal controls in different disease settings. Importantly, these internal controls overcome key limitations of external spike-in controls. Using a global RT-qPCR screen of 1066 miRNAs in plasma from pulmonary hypertension patients (PAH) and healthy subjects as a case example, we identified a large pool of initial candidate miRNAs that were systematically ranked according to their plasma level stability using a predefined algorithm. The performance of the top candidates was validated against multiple comparators, and in a second independent cohort of PAH and control subjects. The broader utility of this approach was demonstrated in a completely different disease setting with 372 miRNAs screened in plasma from septic shock patients and healthy controls. Normalization of data with specific internal reference controls significantly reduced the overall variation in circulating miRNA levels between subjects (relative to raw data), provided a more balanced distribution of up- and down-regulated miRNAs, replicated the results obtained by the benchmark geometric averaging of all detected miRNAs, and outperformed the commonly used external spike-in strategy. We demonstrate the feasibility of identifying circulating reference controls that can reduce extraneous technical variations, and improve the assessment of disease-related changes in plasma miRNA levels. This study provides a novel conceptual framework that addresses a critical and previously unmet need if circulating miRNAs are to advance as reliable diagnostic tools in medicine.
Customized Internal Reference Controls for Improved Assessment of Circulating MicroRNAs in Disease
Schlosser, Kenny; McIntyre, Lauralyn A.; White, R. James; Stewart, Duncan J.
2015-01-01
Background Altered levels of circulating extracellular miRNA in plasma and serum have shown promise as non-invasive biomarkers of disease. However, unlike the assessment of cellular miRNA levels for which there are accepted housekeeping genes, analogous reference controls for normalization of circulating miRNA are lacking. Here, we provide an approach to identify and validate circulating miRNA reference controls on a de novo basis, and demonstrate the advantages of these customized internal controls in different disease settings. Importantly, these internal controls overcome key limitations of external spike-in controls. Methods Using a global RT-qPCR screen of 1066 miRNAs in plasma from pulmonary hypertension patients (PAH) and healthy subjects as a case example, we identified a large pool of initial candidate miRNAs that were systematically ranked according to their plasma level stability using a predefined algorithm. The performance of the top candidates was validated against multiple comparators, and in a second independent cohort of PAH and control subjects. The broader utility of this approach was demonstrated in a completely different disease setting with 372 miRNAs screened in plasma from septic shock patients and healthy controls. Results Normalization of data with specific internal reference controls significantly reduced the overall variation in circulating miRNA levels between subjects (relative to raw data), provided a more balanced distribution of up- and down-regulated miRNAs, replicated the results obtained by the benchmark geometric averaging of all detected miRNAs, and outperformed the commonly used external spike-in strategy. Conclusions We demonstrate the feasibility of identifying circulating reference controls that can reduce extraneous technical variations, and improve the assessment of disease-related changes in plasma miRNA levels. This study provides a novel conceptual framework that addresses a critical and previously unmet need if circulating miRNAs are to advance as reliable diagnostic tools in medicine. PMID:26010841
21 CFR 660.52 - Reference preparations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Reference preparations. 660.52 Section 660.52 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Anti-Human Globulin § 660.52 Reference...
21 CFR 660.3 - Reference panel.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.3 Reference panel. A Reference Hepatitis B Surface Antigen Panel shall be obtained from the Center... shall be used for determining the potency and specificity of Antibody to Hepatitis B Surface Antigen...
21 CFR 660.3 - Reference panel.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.3 Reference panel. A Reference Hepatitis B Surface Antigen Panel shall be obtained from the Center... shall be used for determining the potency and specificity of Antibody to Hepatitis B Surface Antigen...
21 CFR 660.3 - Reference panel.
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.3 Reference panel. A Reference Hepatitis B Surface Antigen Panel shall be obtained from the Center for... used for determining the potency and specificity of Antibody to Hepatitis B Surface Antigen. [40 FR...
21 CFR 660.3 - Reference panel.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.3 Reference panel. A Reference Hepatitis B Surface Antigen Panel shall be obtained from the Center... shall be used for determining the potency and specificity of Antibody to Hepatitis B Surface Antigen...
Mental Health Issues among College Students: Who Gets Referred for Psychopharmacology Evaluation?
ERIC Educational Resources Information Center
Kirsch, Daniel J.; Doerfler, Leonard A.; Truong, Debbie
2015-01-01
Objective: To describe diagnostic and psychotropic medication prescription characteristics among college students referred by college counseling centers for psychopharmacologic evaluation. Participants: Participants were 540 college students referred by 6 college counseling centers in Massachusetts between November 2005 and May 2011. Methods:…
21 CFR 660.3 - Reference panel.
Code of Federal Regulations, 2010 CFR
2010-04-01
... ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.3 Reference panel. A Reference Hepatitis B Surface Antigen Panel shall be obtained from the Center... shall be used for determining the potency and specificity of Antibody to Hepatitis B Surface Antigen...
He, Bosheng; Gu, Jinhua; Huang, Sheng; Gao, Xuesong; Fan, Jinhe; Sheng, Meihong; Wang, Lin; Gong, Shenchu
2017-02-01
This study was performed to evaluate the diagnostic performance of multi-slice CT angiography combined with enterography in determining the cause and location of obstruction as well as intestinal ischaemia in patients with small bowel obstruction (SBO). This study retrospectively summarized the image data of 57 SBO patients who received both multi-slice CT angiography and enterography examination between December 2012 and May 2013. The CT diagnoses of SBO and intestinal ischaemia were correlated with the findings at surgery or digital subtraction angiography, which were set as standard references. Multi-slice CT angiography and enterography indicated that the cause of SBO in three patients was misjudged, suggesting a diagnostic accuracy of 94.7%. In one patient the level of obstruction was incorrect, demonstrating a diagnostic accuracy of 98.2%. Based on the results of the receiver operating characteristic (ROC) curve analysis, the diagnostic criterion for ischaemic SBO was at least two of the four CT signs (circumferential bowel wall thickening, reduced enhancement of the intestinal wall, mesenteric oedema and mesenteric vascular engorgement). The criterion yielded a sensitivity of 94.4%, a specificity of 92.3%, a positive predicted value of 85.0% and a negative predicted value of 97.3%, and the area under curve (AUC) was 0.92 (95% CI, 0.85-0.99). Multi-slice CT angiography and enterography have high diagnostic value in identifying the cause and site of SBO. In addition, the suggested diagnostic criterion using CT signs is helpful for diagnosing intestinal ischaemia in SBO patients. © 2016 The Royal Australian and New Zealand College of Radiologists.
Elmore, Joann G.; Nelson, Heidi D.; Pepe, Margaret S.; Longton, Gary M.; Tosteson, Anna N.A.; Geller, Berta; Onega, Tracy; Carney, Patricia A.; Jackson, Sara L.; Allison, Kimberly H.; Weaver, Donald L.
2016-01-01
Background The effect of physician diagnostic variability on accuracy at a population level depends on the prevalence of diagnoses. Objective To estimate how diagnostic variability affects accuracy from the perspective of a U.S. woman aged 50 to 59 years having a breast biopsy. Design Applied probability using Bayes theorem. Setting B-Path (Breast Pathology) Study comparing pathologists’ interpretations of a single biopsy slide versus a reference consensus interpretation from 3 experts. Participants 115 practicing pathologists (6900 total interpretations from 240 distinct cases). Measurements A single representative slide from each of the 240 cases was used to estimate the proportion of biopsies with a diagnosis that would be verified if the same slide were interpreted by a reference group of 3 expert pathologists. Probabilities of confirmation (predictive values) were estimated using B-Path Study results and prevalence of biopsy diagnoses for women aged 50 to 59 years in the Breast Cancer Surveillance Consortium. Results Overall, if 1 representative slide were used per case, 92.3% (95% CI, 91.4% to 93.1%) of breast biopsy diagnoses would be verified by reference consensus diagnoses, with 4.6% (CI, 3.9% to 5.3%) overinterpreted and 3.2% (CI, 2.7% to 3.6%) underinterpreted. Verification of invasive breast cancer and benign without atypia diagnoses is highly probable; estimated predictive values were 97.7% (CI, 96.5% to 98.7%) and 97.1% (CI, 96.7% to 97.4%), respectively. Verification is less probable for atypia (53.6% overinterpreted and 8.6% underinterpreted) and ductal carcinoma in situ (DCIS) (18.5% overinterpreted and 11.8% underinterpreted). Limitations Estimates are based on a testing situation with 1 slide used per case and without access to second opinions. Population-adjusted estimates may differ for women from other age groups, unscreened women, or women in different practice settings. Conclusion This analysis, based on interpretation of a single breast biopsy slide per case, predicts a low likelihood that a diagnosis of atypia or DCIS would be verified by a reference consensus diagnosis. This diagnostic gray zone should be considered in clinical management decisions in patients with these diagnoses. Primary Funding Source National Cancer Institute. PMID:26999810
van Dijk, R; van Assen, M; Vliegenthart, R; de Bock, G H; van der Harst, P; Oudkerk, M
2017-11-27
Stress cardiovascular magnetic resonance (CMR) perfusion imaging is a promising modality for the evaluation of coronary artery disease (CAD) due to high spatial resolution and absence of radiation. Semi-quantitative and quantitative analysis of CMR perfusion are based on signal-intensity curves produced during the first-pass of gadolinium contrast. Multiple semi-quantitative and quantitative parameters have been introduced. Diagnostic performance of these parameters varies extensively among studies and standardized protocols are lacking. This study aims to determine the diagnostic accuracy of semi- quantitative and quantitative CMR perfusion parameters, compared to multiple reference standards. Pubmed, WebOfScience, and Embase were systematically searched using predefined criteria (3272 articles). A check for duplicates was performed (1967 articles). Eligibility and relevance of the articles was determined by two reviewers using pre-defined criteria. The primary data extraction was performed independently by two researchers with the use of a predefined template. Differences in extracted data were resolved by discussion between the two researchers. The quality of the included studies was assessed using the 'Quality Assessment of Diagnostic Accuracy Studies Tool' (QUADAS-2). True positives, false positives, true negatives, and false negatives were subtracted/calculated from the articles. The principal summary measures used to assess diagnostic accuracy were sensitivity, specificity, andarea under the receiver operating curve (AUC). Data was pooled according to analysis territory, reference standard and perfusion parameter. Twenty-two articles were eligible based on the predefined study eligibility criteria. The pooled diagnostic accuracy for segment-, territory- and patient-based analyses showed good diagnostic performance with sensitivity of 0.88, 0.82, and 0.83, specificity of 0.72, 0.83, and 0.76 and AUC of 0.90, 0.84, and 0.87, respectively. In per territory analysis our results show similar diagnostic accuracy comparing anatomical (AUC 0.86(0.83-0.89)) and functional reference standards (AUC 0.88(0.84-0.90)). Only the per territory analysis sensitivity did not show significant heterogeneity. None of the groups showed signs of publication bias. The clinical value of semi-quantitative and quantitative CMR perfusion analysis remains uncertain due to extensive inter-study heterogeneity and large differences in CMR perfusion acquisition protocols, reference standards, and methods of assessment of myocardial perfusion parameters. For wide spread implementation, standardization of CMR perfusion techniques is essential. CRD42016040176 .
Standardization of Epitopes for Human Chorionic Gonadotropin (hCG) Immunoassays.
Berger, Peter; Lapthorn, Adrian J
2016-01-01
hCG and its variants are markers for pregnancy tests, pregnancyrelated complications, trophoblastic diseases, pre-natal screening of Down's syndrome and doping controls. Strong demands are imposed on diagnostic methods by the dynamic changes in the absolute and relative levels of hCG protein backbone variants and glycosylation isoforms in serum and urine during development of pregnancy or the progression/remission of tumors. Observed differences in the results between commercial diagnostic immunoassays reflect the unequal molar recognition of the different metabolic hCG variants, in particular the hCG beta core fragment (hCGβcf), by the diagnostic antibodies (Abs), as their epitopes are not standardized, and the fact that suboptimal hCG standards are used. To rapidly characterize Abs by their epitope recognition and specificity to evaluate their suitability for diagnostic immunoassays a procedure of comparative epitope mapping has been developed using epitope-defined reference Abs. Comparative epitope mapping of diagnostic Abs will provide the basis for the standardization of diagnostic antigenic domains/epitopes and consequently for improved reliability of hCG measurements. Diagnostic first line assays likely consist of pairs of Abs that recognize specific epitopes at the top of the neighboring peptide loops 1 and 3 (Ł1+3) and the cystine knot (ck) of hCGβ, respectively. In future, significant improvements of reliability, robustness and comparability of the results of immunoassays for complex glycoproteins such as hCG will be achieved by the use (i) of standardized diagnostic Abs against welldefined epitopes and (ii) of the new International Standards for hCG and for five hCG variants established by WHO, that are calibrated in molar (SI) units.
NASA Astrophysics Data System (ADS)
Leray, M.; Boehm, J. T.; Mills, S. C.; Meyer, C. P.
2012-06-01
Identifying species involved in consumer-resource interactions is one of the main limitations in the construction of food webs. DNA barcoding of prey items in predator guts provides a valuable tool for characterizing trophic interactions, but the method relies on the availability of reference sequences to which prey sequences can be matched. In this study, we demonstrate that the COI sequence library of the Moorea BIOCODE project, an ecosystem-level barcode initiative, enables the identification of a large proportion of semi-digested fish, crustacean and mollusks found in the guts of three Hawkfish and two Squirrelfish species. While most prey remains lacked diagnostic morphological characters, 94% of the prey found in 67 fishes had >98% sequence similarity with BIOCODE reference sequences. Using this species-level prey identification, we demonstrate how DNA barcoding can provide insights into resource partitioning, predator feeding behaviors and the consequences of predation on ecosystem function.
Simel, David L; Rennie, Drummond; Bossuyt, Patrick M M
2008-06-01
The Standards for Reporting of Diagnostic Accuracy (STARD) statement provided guidelines for investigators conducting diagnostic accuracy studies. We reviewed each item in the statement for its applicability to clinical examination diagnostic accuracy research, viewing each discrete aspect of the history and physical examination as a diagnostic test. Nonsystematic review of the STARD statement. Two former STARD Group participants and 1 editor of a journal series on clinical examination research reviewed each STARD item. Suggested interpretations and comments were shared to develop consensus. The STARD Statement applies generally well to clinical examination diagnostic accuracy studies. Three items are the most important for clinical examination diagnostic accuracy studies, and investigators should pay particular attention to their requirements: describe carefully the patient recruitment process, describe participant sampling and address if patients were from a consecutive series, and describe whether the clinicians were masked to the reference standard tests and whether the interpretation of the reference standard test was masked to the clinical examination components or overall clinical impression. The consideration of these and the other STARD items in clinical examination diagnostic research studies would improve the quality of investigations and strengthen conclusions reached by practicing clinicians. The STARD statement provides a very useful framework for diagnostic accuracy studies. The group correctly anticipated that there would be nuances applicable to studies of the clinical examination. We offer guidance that should enhance their usefulness to investigators embarking on original studies of a patient's history and physical examination.
Perinetti, Giuseppe; Caprioglio, Alberto; Contardo, Luca
2014-11-01
To evaluate the diagnostic accuracy and repeatability of the visual assessment of the cervical vertebral maturation (CVM) stages. Ten operators underwent training sessions in visual assessment of CVM staging. Subsequently, they were asked to stage 72 cases equally divided into the six stages. Such assessment was repeated twice in two sessions (T1 and T2) 4 weeks apart. A reference standard for each case was created according to a cephalometric analysis of both the concavities and shapes of the cervical vertebrae. The overall agreement with the reference standard was about 68% for both sessions and 76.9% for intrarater repeatability. The overall kappa coefficients with the reference standard were up to 0.86 for both sessions, and 0.88 for intrarater repeatability. Overall, disagreements one stage and twp stage apart were 23.5% (T1) and 5.1% (T2), respectively. Sensitivity ranged from 53.3% for CS5 (T1) to 99.9% for CS1 (T2), positive predictive values ranged from 52.4% for CS5 (T2) to 94.3% for CS6 (T1), and accuracy ranged from 83.6% for CS4 (T2) to 94.9% for CS1 (T1). Visual assessment of the CVM stages is accurate and repeatable to a satisfactory level. About one in three cases remain misclassified; disagreement is generally limited to one stage and is mostly seen in stages 4 and 5.
Plasma free versus deconjugated metanephrines for diagnosis of phaeochromocytoma
Pamporaki, Christina; Därr, Roland; Bursztyn, Michael; Stephan, Glöckner; Bornstein, Stefan R.; Lenders, Jacques W.M.; Pacak, Karel; Krinner, Axel; Eisenhofer, Graeme
2013-01-01
Summary Background Diagnosis of phaeochromocytoma is commonly performed by measurements of plasma free normetanephrine and metanephrine. Plasma deconjugated normetanephrine and metanephrine have been proposed as alternative equivalent, but easier to measure biomarkers. Objective The aim of this study was to compare the diagnostic performances of plasma free versus deconjugated normetanephrine and metanephrine in patients tested for phaeochromocytoma. Methods The study population included a reference group of 262 normotensive and hypertensive volunteers, 198 patients with phaeochromocytoma and 528 patients initially suspected of having the tumour, but with negative investigations after at least 2 years of follow up. Measurements were performed using liquid chromatography with electrochemical detection. Results Median plasma concentrations of free normetanephrine were 17-fold higher in patients with phaeochromocytoma than in the reference population, a 72% larger (p<0.001) difference than that for the 10-fold higher levels of plasma deconjugated normetanephrine. In contrast, relative increases of plasma concentrations of free and deconjugated metanephrine were similar. Using upper cut-offs established in the reference population, measurements of plasma free metabolites provided superior diagnostic performance than deconjugated metabolites according to measures of both sensitivity (97% vs 92%, p=0.002) and specificity (93 vs 89%, p=0.012). The area under the receiver operating characteristic curve for the free metabolites was larger than that for the deconjugated metabolites (0.986 vs 0.965, p<0.001). Conclusion Measurements of plasma free normetanephrine and metanephrine are superior to the deconjugated metabolites for diagnosis of phaeochromocytoma. PMID:23461656
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brent, R.L.
Many professionals are unfamiliar with radiation biology or the quantitative nature of the risks. Frequently, microwave, ultrasound, and ionizing radiation risks are confused. Although it is impossible to prove no risk for any environmental hazard, it appears that exposure to microwave radiation below the maximal permissible levels present no measurable risk to the embryo. Ultrasound exposure from diagnostic ultrasonographic imaging equipment also is quite innocuous. It is true that continued surveillance and research into potential risks of these low-level exposures should continue, but at present ultrasound not only improves obstetric care but also reduces the necessity of diagnostic x-ray procedures.more » In the field of ionizing radiation, we have as good a comprehension of the biologic effects and the quantitative maximum risks as of any other environmental hazard. Although the animal and human data support the conclusion that no increases in the incidence of gross congenital malformations, intrauterine growth retardation, or abortion will occur with exposures less than 5 rad, that does not mean that there are definitely no risks to the embryo exposed to lower doses of radiation. Whether there exists a linear or exponential dose-response relationship or a threshold exposure for genetic, carcinogenic, cell-depleting, and life-shortening effects has not been determined. In establishing maximum permissible levels for the embryo at low exposures, refer to Tables 4, 5, 6, 8, and 9. It is obvious that the risks of 1-rad or 5-rad acute exposure are far below the spontaneous risks of the developing embryo because 15 per cent of human embryos abort, 2.7 to 3.0 per cent of human embryos have major malformations, 4 per cent have intrauterine growth retardation, and 8 to 10 per cent have early- or late-onset genetic disease. 98 references.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wardlaw, Graeme M; Martel, Narine
Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data frommore » 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.« less
NASA Astrophysics Data System (ADS)
Treacy, Páraic Thomas
2018-04-01
Secondary level mathematics education in Ireland has recently experienced a period of significant change with the introduction of new curricula and the addition of an incentive to study upper secondary mathematics at the most advanced level (Higher Level). This incentive, typically referred to as 'bonus points', appears to have aided a significant increase in the number of students studying upper secondary mathematics at Higher Level. However, thematic analysis of interviews with experienced upper secondary mathematics examiners and exploration of mathematics diagnostic test data outlined in this paper suggest that the difficulty of the Higher Level upper secondary mathematics final examination in Ireland has reduced since the introduction of the bonus points initiative. The sharp increase in students attempting this examination coupled with a policy of maintaining a consistent proportion of students achieving passing grades was identified as a key reason for this possible reduction in standards.
Seymour, H R; Matson, M B; Belli, A M; Morgan, R; Kyriou, J; Patel, U
2001-02-01
Rotational digital subtraction angiography (RDSA) allows multidirectional angiographic acquisitions with a single injection of contrast medium. The role of RDSA was evaluated in 60 patients referred over a 7-month period for diagnostic renal angiography and 12 patients referred for renal transplant studies. All angiograms were assessed for their diagnostic value, the presence of anomalies and the quantity of contrast medium used. The effective dose for native renal RDSA was determined. 41 (68.3%) native renal RDSA images and 8 (66.7%) transplant renal RDSA images were of diagnostic quality. Multiple renal arteries were identified in 9/41 (22%) native renal RDSA diagnostic images. The mean volume of contrast medium in the RDSA runs was 51.2 ml and 50 ml for native and transplant renal studies, respectively. The mean effective dose for 120 degrees native renal RDSA was 2.36 mSv, equivalent to 1 year's mean background radiation. Those RDSA images that were non-diagnostic allowed accurate prediction of the optimal angle for further static angiographic series, which is of great value in transplant renal vessels.
Nanotechnology and glaucoma: a review of the potential implications of glaucoma nanomedicine.
Kim, Nathaniel J; Harris, Alon; Gerber, Austin; Tobe, Leslie Abrams; Amireskandari, Annahita; Huck, Andrew; Siesky, Brent
2014-04-01
The purpose of this review is to discuss the evolution of nanotechnology and its potential diagnostic and therapeutic applications in the field of ophthalmology, particularly as it pertains to glaucoma. We reviewed literature using MEDLINE and PubMed databases with the following search terms: glaucoma, nanotechnology, nanomedicine, nanoparticles, ophthalmology and liposomes. We also reviewed pertinent references from articles found in this search. A brief history of nanotechnology and nanomedicine will be covered, followed by a discussion of the advantages and concerns of using this technology in the field of glaucoma. We will look at various studies concerning the development of nanomedicine, its potential applications in ocular drug delivery, diagnostic and imaging modalities and, surgical techniques. In particular, the challenges of assuring safety and efficacy of nanomedicine will be examined. We conclude that nanotechnology offers a novel approach to expanding diagnostic, imaging and surgical modalities in glaucoma and may contribute to the knowledge of disease pathogenesis at a molecular level. However, more research is needed to better elucidate the mechanism of cellular entry, the potential for nanoparticle cytotoxicity and the assurance of clinical efficacy.
Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E
2010-01-01
Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.
Thi Ty Hang, Vu; Thi Han Ny, Nguyen; My Phuc, Tran; Thi Thanh Tam, Pham; Thao Huong, Dang; Dang Trung Nghia, Ho; Tran Anh Vu, Nguyen; Thi Hong Phuong, Pham; Van Xang, Nguyen; Dong, Nguyen; Nhu Hiep, Pham; Van Hung, Nguyen; Tinh Hien, Tran; Rabaa, Maia; Thwaites, Guy E.; Baker, Stephen; Van Tan, Le; van Doorn, H.Rogier
2018-01-01
Background: Acute respiratory infections (ARI) are among the leading causes of hospitalization in children ≤5 years old. Rapid diagnostics of viral pathogens is essential to avoid unnecessary antibiotic treatment, thereby slowing down antibiotic-resistance. We evaluated the diagnostic performance of the Luminex xTAG Respiratory Viral Panel FAST v2 against viral specific PCR as reference assays for ARI in Vietnam. Methods: Four hundred and forty two nose and throat swabs were collected in viral transport medium, and were tested with Luminex xTAG Respiratory Viral Panel FAST v2. Multiplex RT-PCR and single RT-PCR were used as references. Results: Overall, sensitivity of the Luminex against reference assays was 91.8%, 95% CI 88.1-94.7 (270/294), whilst 112/6336 (1.8%, 95% CI, 1.4-2.1) of pathogens were detected by the Luminex, but not by reference assays. Frequency of pathogens detected by Luminex and reference assays was 379 and 292, respectively. The diagnostic yield was 66.7% (295/442, 95%CI 62.1-71.1%) for the Luminex assay and 54.1% (239/442, 95% CI, 49.3-58.8%) for reference assays. The Luminex kit had higher yields for all viruses except influenza B virus, respiratory syncytial virus, and human bocavirus. High agreements between both methods [mean (range): 0.91 (0.83-1.00)] were found for 10/15 viral agents. Conclusions: The Luminex assay is a high throughput multiplex platform for rapid detection of common viral pathogens causing ARI. Although the current high cost may prevent Luminex assays from being widely used, especially in limited resource settings where ARI are felt most, its introduction in clinical diagnostics may help reduce unnecessary use of antibiotic prescription. PMID:29503874
2013-01-01
Background Diagnosis of early-stage hepatocellular carcinoma (HCC) followed by curative resection or liver transplantation offers the best chance for long-term patient survival. Clinically, ultrasonography has suboptimal sensitivity for detecting early-stage HCC. Several serological tests including alpha-fetoprotein (AFP), the ratio of lens culinaris agglutinin-reactive alpha-fetoprotein to total AFP (AFP-L3/AFP), des-gamma carboxyprothrombin (DCP), and glypican-3 (GPC-3) have been widely investigated as diagnostic biomarkers for early-stage HCC in at-risk populations. However, these tests are not recommended for routine HCC screening. Our objective is to determine the diagnostic performance of AFP, AFP-L3/AFP, DCP, and GPC-3 for the detection of HCC, particularly early-stage tumors meeting the Milan criteria. Methods/design We will include cross-sectional studies that consecutively or randomly recruit target populations. We will search the Cochrane Library, Medline, Embase, Science Citation Index, and the Chinese National Knowledge Infrastructure. We will also search the MEDION and ARIF databases to identify diagnostic systematic reviews that include primary studies. Reference lists of relevant reviews will be searched for additional trials. Language restrictions will not be applied. Two reviewers will independently screen study eligibility and extract data. Methodological quality will be assessed according to the revised tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Two authors will apply the QUADAS-2 assessment to all the included studies, and any discrepancies will be resolved by the third author. The following test characteristics will be extracted into 2 × 2 tables for all included studies: true positives, false positives, true negatives, and false negatives. Study-specific estimates of sensitivity and specificity with 95% confidence intervals will be displayed in forest plots. When possible, we will use the bivariate random-effects model or the Rutter and Gatsonis hierarchical summary receiver operating characteristic model for statistical analysis. To investigate heterogeneity, we will include study designs, population characteristics, test characteristics, and types of reference standard as the study-level variables. Discussion Our systematic review will allow patients, clinicians, and researchers to determine the diagnostic performance of AFP, AFP-L3/AFP, DCP, and GPC-3 for the detection of early-stage HCC and the potential roles of these diagnostic biomarkers in the existing diagnostic pathways. Systematic Review Registration: PROSPERO 2013; CRD42013003879 PMID:23738605
Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M
2017-05-25
One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.
Giljaca, Vanja; Nadarevic, Tin; Poropat, Goran; Nadarevic, Vesna Stefanac; Stimac, Davor
2017-03-01
To determine the diagnostic accuracy of abdominal ultrasound (US) for the diagnosis of acute appendicitis (AA), in terms of sensitivity, specificity and post-test probabilities for positive and negative result. A systematic search of MEDLINE, Embase, The Cochrane library and Science Citation Index Expanded from January 1994 to October 2014 was performed. Two authors independently evaluated studies for inclusion, extracted data and performed analyses. The reference standard for evaluation of final diagnosis was pathohistological report on tissue obtained at appendectomy. Summary sensitivity, specificity and post-test probability of AA after positive and negative result of US with corresponding 95% confidence intervals (CI) were calculated. Out of 3306 references identified through electronic searches, 17 reports met the inclusion criteria, with 2841 included participants. The summary sensitivity and specificity of US for diagnosis of AA were 69% (95% CI 59-78%) and 81% (95% CI 73-88%), respectively. At the median pretest probability of AA of 76.4%, the post-test probability for a positive and negative result of US was 92% (95% CI 88-95%) and 55% (95% CI 46-63%), respectively. Abdominal ultrasound does not seem to have a role in the diagnostic pathway for diagnosis of AA in suspected patients. The summary sensitivity and specificity of US do not exceed that of physical examination. Patients that require additional diagnostic workup should be referred to more sensitive and specific diagnostic procedures, such as computed tomography.
Angheben, Andrea; Staffolani, Silvia; Anselmi, Mariella; Tais, Stefano; Degani, Monica; Gobbi, Federico; Buonfrate, Dora; Gobbo, Maria; Bisoffi, Zeno
2017-11-01
We analyzed the accuracy of Chagas Quick Test ® , a rapid diagnostic test, for the diagnosis of chronic Chagas disease through a retrospective study on a cohort of 669 patients consecutively examined at a single reference center in Italy, during a 7-year period. We observed high concordance with serological reference standard but low accuracy for screening purposes (sensitivity/specificity: 82.8%/98.7%) at least in our nonendemic context.
Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W; Arokoski, Jari P; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T; Tervonen, Osmo; Koski, Juhani M; Saarakkala, Simo
2016-03-01
Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level.
Characteristics of binge eating disorder in relation to diagnostic criteria
Wilfley, Denise E; Citrome, Leslie; Herman, Barry K
2016-01-01
The objective of this review was to examine the evidentiary basis for binge eating disorder (BED) with reference to the Diagnostic and Statistical Manual of Mental Disorders – Fifth Edition (DSM-5) diagnostic criteria for BED. A PubMed search restricted to titles and abstracts of English-language reviews, meta-analyses, clinical trials, randomized controlled trials, journal articles, and letters using human participants was conducted on August 7, 2015, using keywords that included “binge eating disorder,” DSM-5, DSM-IV, guilt, shame, embarrassment, quantity, psychological, behavior, and “shape and weight concerns.” Of the 257 retrieved publications, 60 publications were considered relevant to discussions related to DSM-5 diagnostic criteria and were included in the current review, and 20 additional references were also included on the basis of the authors’ knowledge and/or on a review of the reference lists from relevant articles obtained through the literature search. Evidence supports the duration/frequency criterion for BED and the primary importance of loss of control and marked distress in identifying individuals with BED. Although overvaluation of shape/weight is not a diagnostic criterion, its relationship to the severity of BED psychopathology may identify a unique subset of individuals with BED. Additionally, individuals with BED often exhibit a clinical profile consisting of psychiatric (eg, mood, obsessive–compulsive, and impulsive disorders) and medical (eg, gastrointestinal symptoms, metabolic syndrome, and type 2 diabetes) comorbidities and behavioral profiles (eg, overconsumption of calories outside of a binge eating episode and emotional eating). Future revisions of the BED diagnostic criteria should consider the inclusion of BED subtypes, perhaps based on the overvaluation of shape/weight, and an evidence-based reassessment of severity criteria. PMID:27621631
Buechi, Rahel; Faes, Livia; Bachmann, Lucas M; Thiel, Michael A; Bodmer, Nicolas S; Schmid, Martin K; Job, Oliver; Lienhard, Kenny R
2017-12-14
The number of mobile applications addressing health topics is increasing. Whether these apps underwent scientific evaluation is unclear. We comprehensively assessed papers investigating the diagnostic value of available diagnostic health applications using inbuilt smartphone sensors. Systematic Review-MEDLINE, Scopus, Web of Science inclusive Medical Informatics and Business Source Premier (by citation of reference) were searched from inception until 15 December 2016. Checking of reference lists of review articles and of included articles complemented electronic searches. We included all studies investigating a health application that used inbuilt sensors of a smartphone for diagnosis of disease. The methodological quality of 11 studies used in an exploratory meta-analysis was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool and the reporting quality with the 'STAndards for the Reporting of Diagnostic accuracy studies' (STARD) statement. Sensitivity and specificity of studies reporting two-by-two tables were calculated and summarised. We screened 3296 references for eligibility. Eleven studies, most of them assessing melanoma screening apps, reported 17 two-by-two tables. Quality assessment revealed high risk of bias in all studies. Included papers studied 1048 subjects (758 with the target conditions and 290 healthy volunteers). Overall, the summary estimate for sensitivity was 0.82 (95 % CI 0.56 to 0.94) and 0.89 (95 %CI 0.70 to 0.97) for specificity. The diagnostic evidence of available health apps on Apple's and Google's app stores is scarce. Consumers and healthcare professionals should be aware of this when using or recommending them. 42016033049. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Seizures in the elderly: development and validation of a diagnostic algorithm.
Dupont, Sophie; Verny, Marc; Harston, Sandrine; Cartz-Piver, Leslie; Schück, Stéphane; Martin, Jennifer; Puisieux, François; Alecu, Cosmin; Vespignani, Hervé; Marchal, Cécile; Derambure, Philippe
2010-05-01
Seizures are frequent in the elderly, but their diagnosis can be challenging. The objective of this work was to develop and validate an expert-based algorithm for the diagnosis of seizures in elderly people. A multidisciplinary group of neurologists and geriatricians developed a diagnostic algorithm using a combination of selected clinical, electroencephalographical and radiological criteria. The algorithm was validated by multicentre retrospective analysis of data of patients referred for specific symptoms and classified by the experts as epileptic patients or not. The algorithm was applied to all the patients, and the diagnosis provided by the algorithm was compared to the clinical diagnosis of the experts. Twenty-nine clinical, electroencephalographical and radiological criteria were selected for the algorithm. According to criteria combination, seizures were classified in four levels of diagnosis: certain, highly probable, possible or improbable. To validate the algorithm, the medical records of 269 elderly patients were analyzed (138 with epileptic seizures, 131 with non-epileptic manifestations). Patients were mainly referred for a transient focal deficit (40%), confusion (38%), unconsciousness (27%). The algorithm best classified certain and probable seizures versus possible and improbable seizures, with 86.2% sensitivity and 67.2% specificity. Using logistical regression, 2 simplified models were developed, the first with 13 criteria (Se 85.5%, Sp 90.1%), and the second with 7 criteria only (Se 84.8%, Sp 88.6%). In conclusion, the present study validated the use of a revised diagnostic algorithm to help diagnosis epileptic seizures in the elderly. A prospective study is planned to further validate this algorithm. Copyright 2010 Elsevier B.V. All rights reserved.
A case of poor substructure diagnostics
NASA Technical Reports Server (NTRS)
Butler, Thomas G.
1992-01-01
The NASTRAN Manuals in the substructuring area are all geared toward instant success, but the solution paths are fraught with many traps for human error. Thus, the probability of suffering a fatal abort is high. In such circumstances, the necessity for diagnostics that are user friendly is paramount. This paper is written in the spirit of improving the diagnostics as well as the documentation in one area where the author felt he was backed into a blind corner as a result of his having committed a data oversight. This topic is aired by referring to an analysis of a particular structure. The structure, under discussion, used a number of local coordinate systems that simplified the preparation of input data. The principle features of this problem are introduced by reference to a series of figures.
Infrapatellar fat pad disruption: a radiographic sign of patellar tendon rupture.
Chin, Kingsley R; Sodl, Jeffrey F
2005-11-01
After knee trauma, radiographs showing patella alta supercede other signs that suggest patellar tendon rupture. However, without patella alta the diagnosis may be missed. A standard lateral radiograph with the knee flexed showed the infrapatellar fat pad as a dark band with a smooth contour. Our pilot study identified a disruption of the fat pad contour as a radiographic sign of tendon rupture. Two blinded reviewers independently analyzed randomly selected lateral radiographs of the knees of 14 patients with knee injuries. Seven patients had confirmed ruptures diagnosed at surgery, and the other patients had different diagnoses. There were 12 men and two women with an average age of 49 years (range, 20-81 years). One observer detected five of the seven disrupted tendons and six of the seven intact tendons. The other observer detected six of the seven disrupted tendons and all seven intact tendons. Disruption in the contour of the infrapatellar fat pad on routine lateral view radiographs was a reasonably reliable sign of patellar tendon rupture. Diagnostic accuracy should increase when used with the patient's history, physical examination, and other radiographic signs. Absence of this sign should not supersede other suggestive signs of patella tendon rupture. Diagnostic study, Level II (development of diagnostic criteria on consecutive patients--with universally applied reference "gold" standard). See the Guidelines for Authors for a complete description of levels of evidence.
Jafarzadeh, S Reza; Johnson, Wesley O; Gardner, Ian A
2016-03-15
The area under the receiver operating characteristic (ROC) curve (AUC) is used as a performance metric for quantitative tests. Although multiple biomarkers may be available for diagnostic or screening purposes, diagnostic accuracy is often assessed individually rather than in combination. In this paper, we consider the interesting problem of combining multiple biomarkers for use in a single diagnostic criterion with the goal of improving the diagnostic accuracy above that of an individual biomarker. The diagnostic criterion created from multiple biomarkers is based on the predictive probability of disease, conditional on given multiple biomarker outcomes. If the computed predictive probability exceeds a specified cutoff, the corresponding subject is allocated as 'diseased'. This defines a standard diagnostic criterion that has its own ROC curve, namely, the combined ROC (cROC). The AUC metric for cROC, namely, the combined AUC (cAUC), is used to compare the predictive criterion based on multiple biomarkers to one based on fewer biomarkers. A multivariate random-effects model is proposed for modeling multiple normally distributed dependent scores. Bayesian methods for estimating ROC curves and corresponding (marginal) AUCs are developed when a perfect reference standard is not available. In addition, cAUCs are computed to compare the accuracy of different combinations of biomarkers for diagnosis. The methods are evaluated using simulations and are applied to data for Johne's disease (paratuberculosis) in cattle. Copyright © 2015 John Wiley & Sons, Ltd.
[Parental Alienation (Syndrome) - A serious form of child psychological abuse].
von Boch-Galhau, Wilfrid
2018-04-13
Induced parental alienation is a specific form of psychological child abuse, which is listed in DSM-5, the current Diagnostic and Statistical Manual of the American Psychiatric Association (APA), under diagnostic code V 995.51 "child psychological abuse". Untreated induced parental alienation can lead to long-term traumatic psychological and physical effects in the children concerned. This fact is still not given sufficient attention in family court cases. The article gives a condensed overview of parental alienation, summarising its definition, the symptoms and the various levels of severity. It also describes some major alienation techniques and possible psychosomatic and psychiatric effects of induced parental alienation. Finally, attention is drawn to programmes of prevention and intervention now used and evaluated in some countries. The article concludes with two real-life examples from psychiatric practice, and a comprehensive list of international references.
The clinical and laboratory correlates of an increased urinary 5-hydroxyindoleacetic acid.
Tormey, W. P.; FitzGerald, R. J.
1995-01-01
Over a five-and-a-half-year period, there were 298 laboratory requests for urinary 5-hydroxyindoleacetic acid (5-HIAA). The clinical and laboratory associations of the 24 patients in which there were 43 urinary 5-HIAA 24-h collection results greater than the laboratory upper reference limit are detailed. Four were confirmed carcinoid tumours and two were phaeochromocytomas. Flushing was a prominent symptom in 46% and diarrhoea or altered bowel habit in 37%. Associated with the raised urinary 5-HIAA values were increased levels of 4-hydroxy-3-methoxymandelic acid and homovanillic acid in 14.3% and 21%, respectively, of those collections where the metabolites were requested. Diagnostic imaging was performed in 57%. While the specificity was 88%, 5-HIAA is relatively insensitive in the diagnosis of carcinoid tumours and a more widespread use of diagnostic imaging including isotope scanning with labelled metaiodo-benzylguanidine, vasoactive intestinal peptide and octreotide is suggested. PMID:7479466
Neubauer, Aljoscha S; Rothschuh, Antje; Ulbig, Michael W; Blum, Marcus
2008-03-01
Grading diabetic retinopathy in clinical trials is frequently based on 7-field stereo photography of the fundus in diagnostic mydriasis. In terms of image quality, the FF450(plus) camera (Carl Zeiss Meditec AG, Jena, Germany) defines a high-quality reference. The aim of the study was to investigate if the fully digital fundus camera Visucam(PRO NM) could serve as an alternative in clinical trials requiring 7-field stereo photography. A total of 128 eyes of diabetes patients were enrolled in the randomized, controlled, prospective trial. Seven-field stereo photography was performed with the Visucam(PRO NM) and the FF450(plus) camera, in random order, both in diagnostic mydriasis. The resulting 256 image sets from the two camera systems were graded for retinopathy levels and image quality (on a scale of 1-5); both were anonymized and blinded to the image source. On FF450(plus) stereoscopic imaging, 20% of the patients had no or mild diabetic retinopathy (ETDRS level < or = 20) and 29% had no macular oedema. No patient had to be excluded as a result of image quality. Retinopathy level did not influence the quality of grading or of images. Excellent overall correspondence was obtained between the two fundus cameras regarding retinopathy levels (kappa 0.87) and macular oedema (kappa 0.80). In diagnostic mydriasis the image quality of the Visucam was graded slightly as better than that of the FF450(plus) (2.20 versus 2.41; p < 0.001), especially for pupils < 7 mm in mydriasis. The non-mydriatic Visucam(PRO NM) offers good image quality and is suitable as a more cost-efficient and easy-to-operate camera for applications and clinical trials requiring 7-field stereo photography.
Devlin, Hugh; Whelton, Christopher
2015-09-01
The aim of this systematic review was to determine the diagnostic accuracy of the mandibular cortical width measurements and porosity in detecting hip osteoporosis. All of the included studies used measurements on panoramic radiographs. Studies were included if they compared the radiographic measurements (or index tests) with central dual energy X-ray absorptiometry (DXA) of the hip as the reference standard. A measure of diagnostic accuracy such as sensitivity and specificity or area under the receiver operating characteristic curve was also required for inclusion. Seven studies were identified. Meta-analysis was not possible because of the heterogeneity of the studies. The studies all demonstrated moderate diagnostic accuracy. If a patient with a thin or porous mandibular cortex is identified by a chance radiographic finding, additional clinical risk factors need to be considered and the patient referred for further investigation with DXA where necessary. © 2013 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.
Multimodal correlation and intraoperative matching of virtual models in neurosurgery
NASA Technical Reports Server (NTRS)
Ceresole, Enrico; Dalsasso, Michele; Rossi, Aldo
1994-01-01
The multimodal correlation between different diagnostic exams, the intraoperative calibration of pointing tools and the correlation of the patient's virtual models with the patient himself, are some examples, taken from the biomedical field, of a unique problem: determine the relationship linking representation of the same object in different reference frames. Several methods have been developed in order to determine this relationship, among them, the surface matching method is one that gives the patient minimum discomfort and the errors occurring are compatible with the required precision. The surface matching method has been successfully applied to the multimodal correlation of diagnostic exams such as CT, MR, PET and SPECT. Algorithms for automatic segmentation of diagnostic images have been developed to extract the reference surfaces from the diagnostic exams, whereas the surface of the patient's skull has been monitored, in our approach, by means of a laser sensor mounted on the end effector of an industrial robot. An integrated system for virtual planning and real time execution of surgical procedures has been realized.
Rennie, Drummond; Bossuyt, Patrick M. M.
2008-01-01
Summary Objective The Standards for Reporting of Diagnostic Accuracy (STARD) statement provided guidelines for investigators conducting diagnostic accuracy studies. We reviewed each item in the statement for its applicability to clinical examination diagnostic accuracy research, viewing each discrete aspect of the history and physical examination as a diagnostic test. Setting Nonsystematic review of the STARD statement. Interventions Two former STARD Group participants and 1 editor of a journal series on clinical examination research reviewed each STARD item. Suggested interpretations and comments were shared to develop consensus. Measurements and Main Results The STARD Statement applies generally well to clinical examination diagnostic accuracy studies. Three items are the most important for clinical examination diagnostic accuracy studies, and investigators should pay particular attention to their requirements: describe carefully the patient recruitment process, describe participant sampling and address if patients were from a consecutive series, and describe whether the clinicians were masked to the reference standard tests and whether the interpretation of the reference standard test was masked to the clinical examination components or overall clinical impression. The consideration of these and the other STARD items in clinical examination diagnostic research studies would improve the quality of investigations and strengthen conclusions reached by practicing clinicians. Conclusions The STARD statement provides a very useful framework for diagnostic accuracy studies. The group correctly anticipated that there would be nuances applicable to studies of the clinical examination. We offer guidance that should enhance their usefulness to investigators embarking on original studies of a patient’s history and physical examination. PMID:18347878
De Luca Canto, Graziela; Pachêco-Pereira, Camila; Aydinoz, Secil; Major, Paul W.; Flores-Mir, Carlos; Gozal, David
2015-01-01
Objective: The purpose of this systematic review is to evaluate the diagnostic value of biological markers (exhaled breath condensate, blood, salivary and urinary) in the diagnosis of OSA in comparison to the gold standard of nocturnal PSG. Methods: Studies that differentiated OSA from controls based on PSG results, without age restriction, were eligible for inclusion. The sample of selected studies could include studies in obese patients and with known cardiac disease. A detailed individual search strategy for each of the following bibliographic databases was developed: Cochrane, EMBASE, MEDLINE, PubMed, and LILACS. The references cited in these articles were also crosschecked and a partial grey literature search was undertaken using Google Scholar. The methodology of selected studies was evaluated using the 14-item Quality Assessment Tool for Diagnostic Accuracy Studies. Results: After a two-step selection process, nine articles were identified and subjected to qualitative and quantitative analyses. Among them, only one study conducted in children and one in adults found biomarkers that exhibit sufficiently satisfactory diagnostic accuracy that enables application as a diagnostic method for OSA. Conclusion: Kallikrein-1, uromodulin, urocotin-3, and orosomucoid-1 when combined have enough accuracy to be an OSA diagnostic test in children. IL-6 and IL-10 plasma levels have potential to be good biomarkers in identifying or excluding the presence of OSA in adults. Citation: De Luca Canto G, Pachêco-Pereira C, Aydinoz S, Major PW, Flores-Mir C, Gozal D. Diagnostic capability of biological markers in assessment of obstructive sleep apnea: a systematic review and meta-analysis. J Clin Sleep Med 2015;11(1):27–36. PMID:25325575
Baynam, Gareth; Pachter, Nicholas; McKenzie, Fiona; Townshend, Sharon; Slee, Jennie; Kiraly-Borri, Cathy; Vasudevan, Anand; Hawkins, Anne; Broley, Stephanie; Schofield, Lyn; Verhoef, Hedwig; Walker, Caroline E; Molster, Caron; Blackwell, Jenefer M; Jamieson, Sarra; Tang, Dave; Lassmann, Timo; Mina, Kym; Beilby, John; Davis, Mark; Laing, Nigel; Murphy, Lesley; Weeramanthri, Tarun; Dawkins, Hugh; Goldblatt, Jack
2016-06-11
The Rare and Undiagnosed Diseases Diagnostic Service (RUDDS) refers to a genomic diagnostic platform operating within the Western Australian Government clinical services delivered through Genetic Services of Western Australia (GSWA). GSWA has provided a state-wide service for clinical genetic care for 28 years and it serves a population of 2.5 million people across a geographical area of 2.5milion Km(2). Within this context, GSWA has established a clinically integrated genomic diagnostic platform in partnership with other public health system managers and service providers, including but not limited to the Office of Population Health Genomics, Diagnostic Genomics (PathWest Laboratories) and with executive level support from the Department of Health. Herein we describe report presents the components of this service that are most relevant to the heterogeneity of paediatric clinical genetic care. Briefly the platform : i) offers multiple options including non-genetic testing; monogenic and genomic (targeted in silico filtered and whole exome) analysis; and matchmaking; ii) is delivered in a patient-centric manner that is resonant with the patient journey, it has multiple points for entry, exit and re-entry to allow people access to information they can use, when they want to receive it; iii) is synchronous with precision phenotyping methods; iv) captures new knowledge, including multiple expert review; v) is integrated with current translational genomic research activities and best practice; and vi) is designed for flexibility for interactive generation of, and integration with, clinical research for diagnostics, community engagement, policy and models of care. The RUDDS has been established as part of routine clinical genetic services and is thus sustainable, equitably managed and seeks to translate new knowledge into efficient diagnostics and improved health for the whole community.
DIAGNOSTIC ACCURACY OF PHYSICAL EXAMINATION TESTS OF THE ANKLE/FOOT COMPLEX: A SYSTEMATIC REVIEW
Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren
2013-01-01
Background: Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. Purpose: The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. Methods: A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Results: Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Conclusion: Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. Level of Evidence: 3a PMID:24175128
Rösner, Stephan; Gehlweiler, Kevin; Küsters, Uta; Kolbert, Mathias; Hübner, Kirsten; Pfennigwerth, Niels; Mack, Dietrich
2018-01-01
Multidrug-resistant Gram-negative bacilli (MDR-GNB) producing carbapenemases are increasing at an alarming speed. Rapid confirmation of carbapenemase type will be an important diagnostic step in clinical microbiology laboratories not only to reduce the risk of transmissions but also for optimising antibiotic therapy in the future. We compared diagnostic reliability of two commercially available molecular assays (Check-Direct CPE vs. AID line probe assay) for detection and typing of carbapenemase genes in 80 well-characterized isolates of MDR-GNB. Respective strains were isolated in various clinical specimens at our clinical microbiology laboratory. The reference standard included confirmation of carbapenemase-production at the molecular level at the German National Reference Laboratory for Multidrug-resistant Gram-negative bacteria (Ruhr-University Bochum, Germany). 53 Enterobacteriaceae and 27 members of the A. baumannii-complex were used in this study. The tested assays appeared highly reliable to confirm carbapenemase-producing Enterobacteriaceae (CPE) with respective sensitivities of 97.7%, but are currently unsuitable for analysis of members of the A. baumannii-complex. Both assays are easy to perform and rapid tools for confirmation and typing of the most common carbapenemase genes in Enterobacteriaceae. Implementation should be possible for any clinical microbiology laboratory with Check-Direct CPE being easier to handle and having less technological requirements.
Acquazzino, Melissa A; Miller, Meghan; Myrvik, Matthew; Newby, Robert; Scott, John Paul
2017-07-01
Neuropsychological deficits, including difficulties with attention, are well described in children with sickle cell disease (SCD). Very little is known about attention deficit hyperactivity disorder (ADHD) in children with SCD. The objective of this study was to determine the proportion of ADHD in children with SCD referred for neuropsychological evaluation. This prospective, cross-sectional study included patients (age, 4 to 18 y) with SCD and completion of a neuropsychological evaluation between December 2013 and March 2016. Patients were referred for neuropsychological evaluation because of concern regarding school performance, development, and/or behavior. The diagnosis of ADHD was made by a neuropsychologist on the basis of the diagnostic criteria in the Diagnostic Statistical Manual-Fourth or Fifth Editions. ADHD medication usage rate was obtained by medical record review. Of the 89 patients with SCD referred for neuropsychological evaluation, 25% (95% confidence interval, 16%-35%) met diagnostic criteria for ADHD. Only 21% of the patients with SCD and ADHD were prescribed an ADHD medication. Our study supports routine ADHD screening in children with SCD who have poor school performance or behavioral concerns. Despite the benefits of pharmacologic treatment, the majority of patients with SCD and ADHD did not receive a medication for management of their ADHD.
42 CFR 493.1264 - Standard: Parasitology.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1264 Standard: Parasitology. (a) The laboratory must have available a reference collection... these references in the laboratory for appropriate comparison with diagnostic specimens. (b) The...
Genetics Home Reference: carnitine palmitoyltransferase II deficiency
... Zierz S. Muscle carnitine palmitoyltransferase II deficiency: clinical and molecular genetic features and diagnostic aspects. Arch Neurol. 2005 Jan; ... K, Hermann T, Zierz S. Carnitine palmitoyltransferase II deficiency: molecular and biochemical analysis of 32 ... Bulletins Genetics Home Reference Celebrates Its ...
MO-E-18A-01: Imaging: Best Practices In Pediatric Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willis, C; Strauss, K; MacDougall, R
This imaging educational program will focus on solutions to common pediatric imaging challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children's hospitals. Areas of focus will include general radiography, the use of manual and automatic dose management in computed tomography, and enterprise-wide radiation dose management in the pediatric practice. The educational program will begin with a discussion of the complexities of exposure factor control in pediatric projection radiography. Following this introduction will be two lectures addressing the challenges of computed tomography (CT) protocol optimization in the pediatric population. The firstmore » will address manual CT protocol design in order to establish a managed radiation dose for any pediatric exam on any CT scanner. The second CT lecture will focus on the intricacies of automatic dose modulation in pediatric imaging with an emphasis on getting reliable results in algorithmbased technique selection. The fourth and final lecture will address the key elements needed to developing a comprehensive radiation dose management program for the pediatric environment with particular attention paid to new regulations and obligations of practicing medical physicists. Learning Objectives: To understand how general radiographic techniques can be optimized using exposure indices in order to improve pediatric radiography. To learn how to establish diagnostic dose reference levels for pediatric patients as a function of the type of examination, patient size, and individual design characteristics of the CT scanner. To learn how to predict the patient's radiation dose prior to the exam and manually adjust technique factors if necessary to match the patient's dose to the department's established dose reference levels. To learn how to utilize manufacturer-provided automatic dose modulation technology to consistently achieve patient doses within the department's established size-based diagnostic reference range. To understand the key components of an enterprise-wide pediatric dose management program that integrates the expanding responsibilities of medial physicists in the new era of dose monitoring.« less
Dones, Valentin C; Grimmer, Karen; Thoirs, Kerry; Suarez, Consuelo G; Luker, Julie
2014-03-03
Ultrasound is considered a reliable, widely available, non-invasive and inexpensive imaging technique for assessing soft tissue involvement in Lateral epicondylalgia. Despite the number of diagnostic studies for Lateral Epicondylalgia, there is no consensus in the current literature on the best abnormal ultrasound findings that confirm lateral epicondylalgia. Eligible studies identified by searching electronic databases, scanning reference lists of articles and chapters on ultrasound in reference books, and consultation of experts in sonography. Three reviewers (VCDIII, KP, KW) independently searched the databases using the agreed search strategy, and independently conducted all stages of article selection. Two reviewers (VCDIII, KP) then screened titles and abstracts to remove obvious irrelevance. Potentially relevant full text publications which met the inclusion criteria were reviewed by the primary investigator (VCDIII) and another reviewer (CGS). Among the 15 included diagnostic studies in this review, seven were Level II diagnostic accuracy studies for chronic lateral epicondylalgia based on the National Health and Medical Research Council Hierarchy of Evidence. Based from the pooled sensitivity of abnormal ultrasound findings with homogenous results (p > 0.05), the hypoechogenicity of the common extensor origin has the best combination of diagnostic sensitivity and specificity. It is moderately sensitive [Sensitivity: 0.64 (0.56-0.72)] and highly specific [Specificity: 0.82 (0.72-0.90)] in determining elbows with lateral epicondylalgia. Additionally, bone changes on the lateral epicondyle [Sensitivity: 0.56 (0.50-0.62)] were moderately sensitive to chronic LE. Conversely, neovascularity [Specificity: 1.00 (0.97-1.00)], calcifications [Specificity: 0.97 (0.94-0.99)] and cortical irregularities [Specificity: 0.96 (0.88-0.99)] have strong specificity for chronic lateral epicondylalgia. There is insufficient evidence supporting the use of Power Doppler Ultrasonogrophy, Real-time Sonoelastography and sonographic probe-induced tenderness in diagnosing LE. The use of Gray-scale Ultrasonography is recommended in objectively diagnosing lateral epicondylalgia. The presence of hypoechogenicity and bone changes indicates presence of a stressed common extensor origin-lateral epicondyle complex in elbows with lateral epicondylalgia. In addition to diagnosis, detection of these abnormal ultrasound findings allows localization of pathologies to tendon or bone that would assist in designing an appropriate treatment suited to patient's condition.
Increasing Access to Tuberculosis Services in Ethiopia: Findings From a Patient-Pathway Analysis.
Fekadu, Lelisa; Hanson, Christy; Osberg, Mike; Makayova, Julia; Mingkwan, Pia; Chin, Daniel
2017-11-06
In Ethiopia, extensive scale-up of the availability of health extension workers (HEWs) at the community level has been credited with increased identification and referral of patients with presumptive tuberculosis, which has contributed to increased tuberculosis case notification and better treatment outcomes. However, nearly 30% of Ethiopia's estimated 191000 patients with tuberculosis remained unnotified in 2015. A better understanding of patient care-seeking practices may inform future government action to reach all patients with tuberculosis. A patient-pathway analysis was completed to assess the alignment between patient care initiation and the availability of diagnostic and treatment services at the national level. More than one third of patients initiated care with HEWs, who refer patients to health centers for diagnosis. An additional one third of patients initiated care at health centers. Of those health centers, >80% had microscopy services, but few had access to Xpert. Despite an extensive microscopy and radiography network at middle levels of the health system, a quarter of all notified patients with tuberculosis had no bacteriological confirmation of disease. While 30% of patients reported receiving some form of care from the private sector, private-sector facilities, especially pharmacies, were not widely accessed for tuberculosis diagnosis. The availability of HEWs can increase access to tuberculosis diagnostic and treatment support services, particularly for rural populations. Continued strengthening of referral systems from HEWs and health posts are needed to enable consistent and timely access to Xpert as an initial diagnostic test and to drug resistance screening. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Screening for Learning Disabilities in Adult Basic Education Students
ERIC Educational Resources Information Center
Reynolds, Sharon L.; Johnson, Jerry D.; Salzman, James A.
2012-01-01
The extant literature offers little to describe the processes for screening students in adult basic education (ABE) programs for potential learning disabilities, referring adult students for diagnostic assessment, or barriers to obtaining diagnostic assessment for a learning disability. Without current documentation of a learning disability, ABE…
Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt.
Salama, Dina Husseiny; Vassileva, Jenia; Mahdaly, Gamal; Shawki, Mona; Salama, Ahmad; Gilley, Debbie; Rehani, Madan Mohan
2017-07-01
To establish national diagnostic reference levels (DRLs) in Egypt for computed tomography (CT) examinations of adults and identify the potential for optimization. Data from 3762 individual patient's undergoing CT scans of head, chest (high resolution), abdomen, abdomen-pelvis, chest-abdomen-pelvis and CT angiography (aorta and both lower limbs) examinations in 50 CT facilities were collected. This represents 20% of facilities in the country and all of the 27 Governorates. Results were compared with DRLs of UK, USA, Canada, Japan, Australia and France. The Egyptian DRLs for CTDI vol in mGy are for head: 30, chest (high resolution): 22, abdomen (liver metastasis): 31, abdomen-pelvis: 31, chest-abdomen-pelvis: 33 and CT angiography (aorta and lower limbs): 37. The corresponding DRLs for DLP in mGy.cm are 1360, 420, 1425, 1325, 1320 and 1320. For head CT, the Egyptian DRL for CTDI vol is 2-3 times lower than the DRLs from other countries. However, the DRL in terms of DLP is in the same range or higher as compared to others. The Egyptian DRL for chest CT (high resolution) is similar to others for DLP but higher for CTDI vol . For abdomen and abdomen-pelvis DRLs for CTDI vol are higher than others. For DLP, the DRLs for abdomen are higher than DRL in UK and lower than those in Japan, while for abdomen-pelvis they are higher than other countries. Despite lower DRLs for CTDI vol , an important consistent problem appears to be higher scan range as DRLs for DLP are higher. Copyright © 2017 Associazione Italiana di Fisica Medica. All rights reserved.
Wagner, Franca; Bize, Julie; Racine, Damien; Le Coultre, Regis; Francis, Verdun; Trueb, Philipp; Treier, Reto
2018-05-22
Definition of new national diagnostic reference levels (DRLs) for volume computed tomography dose index (CTDIvol) and dose length product (DLP) for neuro-paediatric CT examinations depending on the medical indication. Methods: Paediatric cranial CT data sets acquired between January 2013 and December 2016 were retrospectively collected between July 2016 and March 2017 from the eight largest university and cantonal hospitals that perform most of the neuro-paediatric CTs in Switzerland. A consensus review of CTDIvol and DLP was undertaken for the three defined anatomical regions: brain, facial bone and petrous bone; each with and without contrast medium application. All indications for cranial CT imaging in paediatrics were assigned to one of these three regions. Descriptive statistical analysis of the distribution of the median values for CTDIvol and DLP yielded minimum, maximum, 25th percentile (1st quartile), median (2nd quartile) and 75th percentile (3rd quartile). New DRLs for neuro-paediatric CT examinations in Switzerland were based on the 75th percentiles of the distributions of the median values of all eight centres. Where appropriate, values were rounded such that the DRLs increase or at least remain constant as the age of the patient increases. Results: Our results revealed DRLs for CTDIvol and DLP up to 20% lower than the DRLs used so far in Switzerland and elsewhere in Europe. Conclusions: This study provides Swiss neuro-paediatric CT DRL values to establish optimum conditions for paediatric cranial CT examinations. Periodic national updates of DRLs, following international comparisons, are essential. . Creative Commons Attribution license.
Comte, Alexia; Gräfenhan, Tom; Links, Matthew G; Hemmingsen, Sean M; Dumonceaux, Tim J
2017-01-01
We examined the epiphytic microbiome of cereal grain using the universal barcode chaperonin-60 (cpn60). Microbial community profiling of seed washes containing DNA extracts prepared from field-grown cereal grain detected sequences from a fungus identified only to Class Sordariomycetes. To identify the fungal sequence and to improve the reference database, we determined cpn60 sequences from field-collected and reference strains of the ergot fungus, Claviceps purpurea. These data allowed us to identify this fungal sequence as deriving from C. purpurea, and suggested that C. purpurea DNA is readily detectable on agricultural commodities, including those for which ergot was not identified as a grading factor. To get a sense of the prevalence and level of C. purpurea DNA in cereal grains, we developed a quantitative PCR assay based on the fungal internal transcribed spacer (ITS) and applied it to 137 samples from the 2014 crop year. The amount of Claviceps DNA quantified correlated strongly with the proportion of ergot sclerotia identified in each grain lot, although there was evidence that non-target organisms were responsible for some false positives with the ITS-based assay. We therefore developed a cpn60-targeted loop-mediated isothermal amplification assay and applied it to the same grain wash samples. The time to positive displayed a significant, inverse correlation to ergot levels determined by visual ratings. These results indicate that both laboratory-based and field-adaptable molecular diagnostic assays can be used to detect and quantify pathogen load in bulk commodities using cereal grain washes.
Comte, Alexia; Gräfenhan, Tom; Links, Matthew G.; Hemmingsen, Sean M.
2017-01-01
We examined the epiphytic microbiome of cereal grain using the universal barcode chaperonin-60 (cpn60). Microbial community profiling of seed washes containing DNA extracts prepared from field-grown cereal grain detected sequences from a fungus identified only to Class Sordariomycetes. To identify the fungal sequence and to improve the reference database, we determined cpn60 sequences from field-collected and reference strains of the ergot fungus, Claviceps purpurea. These data allowed us to identify this fungal sequence as deriving from C. purpurea, and suggested that C. purpurea DNA is readily detectable on agricultural commodities, including those for which ergot was not identified as a grading factor. To get a sense of the prevalence and level of C. purpurea DNA in cereal grains, we developed a quantitative PCR assay based on the fungal internal transcribed spacer (ITS) and applied it to 137 samples from the 2014 crop year. The amount of Claviceps DNA quantified correlated strongly with the proportion of ergot sclerotia identified in each grain lot, although there was evidence that non-target organisms were responsible for some false positives with the ITS-based assay. We therefore developed a cpn60-targeted loop-mediated isothermal amplification assay and applied it to the same grain wash samples. The time to positive displayed a significant, inverse correlation to ergot levels determined by visual ratings. These results indicate that both laboratory-based and field-adaptable molecular diagnostic assays can be used to detect and quantify pathogen load in bulk commodities using cereal grain washes. PMID:28257512
Fecal calprotectin in coeliac disease.
Capone, Pietro; Rispo, Antonio; Imperatore, Nicola; Caporaso, Nicola; Tortora, Raffaella
2014-01-14
We would like to share with the readers the results of our experience in 50 celiac disease (CD) patients, enrolled between September 2012 and April 2013, who were referred to our third-level CD Unit. The fecal calprotectin (FC) concentration of 50 adults with newly diagnosed CD was compared to that of a control group of 50 healthy subjects. FC level was determined by enzyme linked immunosorbent assay with diagnostic cut-off of 75 μg/g. In addition, we tried to correlate the FC level with symptoms, histological severity of CD (Marsh grade) and level of tissue transglutaminase antibodies (aTg) in CD patients. Finally, FC level was increased in five CD patients and in four controls (10% vs 8%, P = NS); mean FC concentration of patients and controls were 57.7 (SD ± 29.1) and 45.1 (SD ± 38.4) respectively. Furthermore, no significant correlation was seen between FC levels and symptoms/Marsh grade/aTg. The five CD patients did not show inflammatory lesions (e.g., ulcers, erosions) at upper endoscopy. The four healthy controls with positive FC were followed-up for further six months; in this observational period they did not show clinical signs of any underlying disease. On these bases, we think that FC is not able to investigate the subclinical inflammatory changes of active CD and FC should be considered a useless tool in the diagnostic work-up of uncomplicated CD but it should be accompanied by aTg when ruling out organic disease in patients with irritable bowel syndrome.
3D-CAM: Derivation and Validation of a 3-Minute Diagnostic Interview for CAM-defined Delirium
Marcantonio, Edward R.; Ngo, Long H.; O’Connor, Margaret; Jones, Richard N.; Crane, Paul K.; Metzger, Eran D.; Inouye, Sharon K.
2015-01-01
Background Delirium is common, morbid, and costly, yet remains often unrecognized in most clinical settings. The Confusion Assessment Method (CAM) is the most widely used diagnostic algorithm, and operationalizing its features would represent a substantial advance for clinical care. Objective To derive the 3D-CAM, a new 3-minute diagnostic assessment for CAM-defined delirium, and to validate it against a clinical reference standard. Design Diagnostic test study Setting 4 general medicine units in an academic medical center Participants 201 inpatients aged ≥ 75 years old Measurements We identified 20 items that best operationalized the 4 CAM diagnostic features to create the 3D-CAM. For prospective validation, 3D-CAM assessments were administered by trained research assistants. Independently, clinicians performed an extensive assessment that included patient interviews, family interviews, and review of the medical record. These data were considered by an expert panel to determine the presence or absence of delirium and dementia (reference standard). We compared the 3D-CAM delirium determination to the reference standard in all patients and in subgroups with and without dementia. Results The 201 participants in the prospective validation study had mean age (SD) of 84 (5.5) years, and 27% had dementia. The expert panel identified delirium in 21%. Median administration time for 3D-CAM was 3 minutes (inter-quartile range: 2–5 minutes). The sensitivity [95% CI] of 3D-CAM was 95% [84%, 99%] and the specificity was 94% [90%, 97%]. The 3D-CAM performed well in patients both with dementia (sensitivity=96% [82%, 100%], specificity=86% [67%, 96%]) and without dementia (sensitivity=93% [66%, 100%], specificity=96% [91%,99%]). Limitations Limited to single center, cross-sectional, and medicine patients only Conclusion The 3D-CAM operationalizes the CAM algorithm using a 3-minute structured assessment with high sensitivity and specificity relative to a reference standard and could be an important tool for improving recognition of delirium. PMID:25329203
Boosting medical diagnostics by pooling independent judgments
Kurvers, Ralf H. J. M.; Herzog, Stefan M.; Hertwig, Ralph; Krause, Jens; Carney, Patricia A.; Bogart, Andy; Argenziano, Giuseppe; Zalaudek, Iris; Wolf, Max
2016-01-01
Collective intelligence refers to the ability of groups to outperform individual decision makers when solving complex cognitive problems. Despite its potential to revolutionize decision making in a wide range of domains, including medical, economic, and political decision making, at present, little is known about the conditions underlying collective intelligence in real-world contexts. We here focus on two key areas of medical diagnostics, breast and skin cancer detection. Using a simulation study that draws on large real-world datasets, involving more than 140 doctors making more than 20,000 diagnoses, we investigate when combining the independent judgments of multiple doctors outperforms the best doctor in a group. We find that similarity in diagnostic accuracy is a key condition for collective intelligence: Aggregating the independent judgments of doctors outperforms the best doctor in a group whenever the diagnostic accuracy of doctors is relatively similar, but not when doctors’ diagnostic accuracy differs too much. This intriguingly simple result is highly robust and holds across different group sizes, performance levels of the best doctor, and collective intelligence rules. The enabling role of similarity, in turn, is explained by its systematic effects on the number of correct and incorrect decisions of the best doctor that are overruled by the collective. By identifying a key factor underlying collective intelligence in two important real-world contexts, our findings pave the way for innovative and more effective approaches to complex real-world decision making, and to the scientific analyses of those approaches. PMID:27432950
Base Rates: Both Neglected and Intuitive
ERIC Educational Resources Information Center
Pennycook, Gordon; Trippas, Dries; Handley, Simon J.; Thompson, Valerie A.
2014-01-01
Base-rate neglect refers to the tendency for people to underweight base-rate probabilities in favor of diagnostic information. It is commonly held that base-rate neglect occurs because effortful (Type 2) reasoning is required to process base-rate information, whereas diagnostic information is accessible to fast, intuitive (Type 1) processing…
From Colorado to Guam: Infant Diagnostic Audiological Evaluations by Telepractice
ERIC Educational Resources Information Center
Hayes, Deborah; Eclavea, Elaine; Dreith, Susan; Habte, Bereket
2012-01-01
This manuscript describes a pilot project in which infants in Guam who refer on newborn hearing screening receive diagnostic audiological evaluation conducted by audiologists in Colorado over the Internet (telepractice). The evaluation is completed in real time using commercially-available software and personal computers to control the diagnostic…
de Jongh, Ad; Fransen, Jolanda; Oosterink-Wubbe, Floor; Aartman, Irene
2006-08-01
This questionnaire-based study investigated the traumatic background and trauma-related symptomatology among 141 treatment-seeking individuals with high levels of dental anxiety and among a low-anxious reference group consisting of 99 regular dental patients. The highly anxious individuals reported a significantly higher number of traumatic events, both within and outside the dental or medical setting, than those in the reference group (73% vs. 21%). Horrific experiences in the dental setting were the most common traumatic events reported. Of the highly anxious individuals, 46.1% indicated suffering from one or more of the post-traumatic stress disorder (PTSD) symptom clusters (re-experiencing, avoidance, loss of interest, and insomnia), while in the reference group this percentage was 6%. Severity of dental anxiety was significantly associated with number of screening criteria for specific phobia and the extent to which the anxious subjects displayed symptoms of post-traumatic stress. Two variables were uniquely predictive for positive diagnostic screens for dental phobia and PTSD: having experienced a horrific dental treatment and having been a victim of a violent crime. In conclusion, post-traumatic symptoms are common accompaniments of severe forms of dental anxiety and are experienced even when dental treatment is not imminent.
Ejlersen, June A; May, Ole; Mortensen, Jesper; Nielsen, Gitte L; Lauridsen, Jeppe F; Allan, Johansen
2017-11-01
Patients with normal stress perfusion have an excellent prognosis. Prospective studies on the diagnostic accuracy of stress-only scans with contemporary, independent examinations as gold standards are lacking. A total of 109 patients with typical angina and no previous coronary artery disease underwent a 2-day stress (exercise)/rest, gated, and attenuation-corrected (AC), 99m-technetium-sestamibi perfusion study, followed by invasive coronary angiography. The stress datasets were evaluated twice by four physicians with two different training levels (expert and novice): familiar and unfamiliar with AC. The two experts also made a consensus reading of the integrated stress-rest datasets. The consensus reading and quantitative data from the invasive coronary angiography were applied as reference methods. The sensitivity/specificity were 0.92-1.00/0.73-0.90 (reference: expert consensus reading), 0.93-0.96/0.63-0.82 (reference: ≥1 stenosis>70%), and 0.75-0.88/0.70-0.88 (reference: ≥1 stenosis>50%). The four readers showed a high and fairly equal sensitivity independent of their familiarity with AC. The expert familiar with AC had the highest specificity independent of the reference method. The intraobserver and interobserver agreements on the stress-only readings were good (readers without AC experience) to excellent (readers with AC experience). AC stress-only images yielded a high sensitivity independent of the training level and experience with AC of the nuclear physician, whereas the specificity correlated positively with both. Interobserver and intraobserver agreements tended to be the best for physicians with AC experience.
Plasma-free vs deconjugated metanephrines for diagnosis of phaeochromocytoma.
Pamporaki, Christina; Därr, Roland; Bursztyn, Michael; Glöckner, Stephan; Bornstein, Stefan R; Lenders, Jacques W M; Pacak, Karel; Krinner, Axel; Eisenhofer, Graeme
2013-10-01
The diagnosis of phaeochromocytoma is commonly performed by the measurements of plasma-free normetanephrine and metanephrine. Plasma-deconjugated normetanephrine and metanephrine have been proposed as alternative, equivalent, but easier to measure biomarkers. The aim of this study was to compare the diagnostic performance of plasma-free vs deconjugated normetanephrine and metanephrine in patients tested for phaeochromocytoma. The study population included a reference group of 262 normotensive and hypertensive volunteers, 198 patients with phaeochromocytoma and 528 patients initially suspected of having the tumour, but with negative investigations after at least 2 years of follow-up. Measurements were performed using liquid chromatography with electrochemical detection. Plasma concentrations of free normetanephrine were 17-fold higher in patients with phaeochromocytoma than in the reference population, a 72% larger (P < 0·001) difference than that for the 10-fold higher levels of plasma-deconjugated normetanephrine. In contrast, relative increases in plasma concentrations of free and deconjugated metanephrine were similar. Using upper cut-offs established in the reference population, measurements of plasma-free metabolites provided superior diagnostic performance than deconjugated metabolites according to measures of both sensitivity (97% vs 92%, P = 0·002) and specificity (93% vs 89%, P = 0·012). The area under the receiver operating characteristic curve for the free metabolites was larger than that for the deconjugated metabolites (0·986 vs 0·965, P < 0·001). Measurements of plasma-free normetanephrine and metanephrine are superior to the deconjugated metabolites for diagnosis of phaeochromocytoma. © 2013 John Wiley & Sons Ltd.
Lalji, U C; Houben, I P L; Prevos, R; Gommers, S; van Goethem, M; Vanwetswinkel, S; Pijnappel, R; Steeman, R; Frotscher, C; Mok, W; Nelemans, P; Smidt, M L; Beets-Tan, R G; Wildberger, J E; Lobbes, M B I
2016-12-01
Contrast-enhanced spectral mammography (CESM) is a promising problem-solving tool in women referred from a breast cancer screening program. We aimed to study the validity of preliminary results of CESM using a larger panel of radiologists with different levels of CESM experience. All women referred from the Dutch breast cancer screening program were eligible for CESM. 199 consecutive cases were viewed by ten radiologists. Four had extensive CESM experience, three had no CESM experience but were experienced breast radiologists, and three were residents. All readers provided a BI-RADS score for the low-energy CESM images first, after which the score could be adjusted when viewing the entire CESM exam. BI-RADS 1-3 were considered benign and BI-RADS 4-5 malignant. With this cutoff, we calculated sensitivity, specificity and area under the ROC curve. CESM increased diagnostic accuracy in all readers. The performance for all readers using CESM was: sensitivity 96.9 % (+3.9 %), specificity 69.7 % (+33.8 %) and area under the ROC curve 0.833 (+0.188). CESM is superior to conventional mammography, with excellent problem-solving capabilities in women referred from the breast cancer screening program. Previous results were confirmed even in a larger panel of readers with varying CESM experience. • CESM is consistently superior to conventional mammography • CESM increases diagnostic accuracy regardless of a reader's experience • CESM is an excellent problem-solving tool in recalls from screening programs.
Fever of unknown origin (FUO): CMV infectious mononucleosis or lymphoma?
Cunha, Burke A; Chawla, Karishma
2018-07-01
Fever of unknown origin (FUO) refers to fevers of > 101 °F that persist for > 3 weeks and remain undiagnosed after a focused inpatient or outpatient workup. FUO may be due to infectious, malignant/neoplastic, rheumatic/inflammatory, or miscellaneous disorders. The FUO category determines the focus of the diagnostic workup. In the case presented of an FUO in a young woman, there were clinical findings of both CMV infectious mononucleosis or a lymphoma, e.g., highly elevated ESR, elevated ferritin levels, and elevated ACE level, β-2 microglobulins. The indium scan showed intense splenic uptake. Lymph node biopsy, PET scan, and flow cytometry were negative for lymphoma. CMV infectious mononucleosis was the diagnosis, and she made a slow recovery.
Reference levels of trace elements in hair samples from children and adolescents in Madrid, Spain.
Llorente Ballesteros, María Teresa; Navarro Serrano, Irene; Izquierdo Álvarez, Silvia
2017-09-01
Hair samples are used as a tool to evaluate environmental exposure to contaminants and metabolic status in the individual. However, the use of human hair is controversial, mainly because of the lack of well-defined reference levels. In the case of Spain, very few biomonitoring studies have investigated these issues in infants, children or adolescents. To establish reference levels for trace elements in children and teenagers in Madrid, Spain. Inductively coupled plasma mass spectrometry (ICP-MS) was used to measure Al, As, Ag, Ba, Bi, Cd, Cr, Co, Cu, Fe, Mn, Mo, Ni, Pb, Se, Sr, Tl and Zn levels in hair samples from 648 healthy children and adolescents (253 boys and 395 girls) between April 2008 and December 2009. Median levels were as follows: Al 18.5μg/g, As 0.07μg/g, Ag 196ng/g, Ba 0.5μg/g, Bi 0.01μg/g, Cd 18.3ng/g, Cr 0.4μg/g, Co 14.5ng/g, Cu 25.7μg/g, Fe 15.5μg/g, Mn 328ng/g, Mo 0.04μg/g, Ni 0.5μg/g, Pb 0.70μg/g, Se 0.5μg/g, Sr 1.29μg/g, Tl 0.28ng/g and Zn 121μg/g. The values of trace elements here described could be considered as possible reference ranges for hair samples from children and adolescents aged 0-18 years living in the Madrid region (central Spain). These values could also be selected as a preliminary screening tool to assess exposure sources and to generate information needed to develop prevention strategies and likewise could be a complement to other diagnostic procedures. Copyright © 2016 Elsevier GmbH. All rights reserved.
Diagnostic Accuracy of a Self-Report Measure of Patellar Tendinopathy in Youth Basketball.
Owoeye, Oluwatoyosi B A; Wiley, J Preston; Walker, Richard E A; Palacios-Derflingher, Luz; Emery, Carolyn A
2018-04-27
Study Design Prospective diagnostic accuracy validation study. Background Engaging clinicians for diagnosis of patellar tendinopathy in large surveillance studies is often impracticable. A self-report measure, the Oslo Sports Research Trauma Centre patellar tendinopathy (OSTRC-P) Questionnaire, an adaptation of the OSTRC Questionnaire may provide a viable alternative. Objectives To evaluate the diagnostic accuracy of the OSTRC-P Questionnaire in detecting patellar tendinopathy in youth basketball players when compared to clinical evaluation. Methods Following the Standards for Reporting of Diagnostic Accuracy Studies guidelines, 208 youth basketball players (aged 13-18 years) were recruited. Participants completed the OSTRC-P Questionnaire (index test) prior to a clinical evaluation (reference standard) by a physiotherapist blinded to OSTRC-P Questionnaire results. Sensitivity, specificity, predictive values (PVs), likelihood ratios (LRs) and posttest probabilities were calculated. Linear regression was used to examine the association between OSTRC-P Questionnaire severity score and patellar tendinopathy severity rating during single leg decline squat (SLDS). Results The final analysis included 169 players. The OSTRC-P Questionnaire had a sensitivity of 79% (95%CI: 65%, 90%), specificity of 98% (95%CI: 94%, 100%), positive PV of 95%, negative PV of 92%, positive LR of 48 and negative LR of 0.21. The posttest probabilities were 95% and 8% given positive and negative results, respectively. A positive association was found between OSTRC-P Questionnaire and SLDS rating [(β = .08 (95%CI: .03, .12) (p = .001)]. Conclusions The OSTRC-P Questionnaire is an acceptable alternative to clinical evaluation for self-reporting patellar tendinopathy and grading its severity in settings involving youth basketball players. Level of Evidence Diagnosis, level 1b. J Orthop Sports Phys Ther, Epub 27 Apr 2018. doi:10.2519/jospt.2018.8088.
Słapa, Rafał Z.; Jakubowski, Wiesław S.; Migda, Bartosz; Dmowski, Tadeusz
2014-01-01
Aim Sonoelastography is a technique that assesses tissue hardness/compressibility. Utility and sensitivity of the method in prostate cancer diagnostics were assessed compared to the current gold standard in prostate cancer diagnostics i.e. systematic biopsy. Material and methods The study involved 84 patients suspected of prostate cancer based on elevated PSA levels or abnormal per rectal examination findings. Sonoelastography was used to evaluate the prostate gland. In the case of regions with hardness two-fold greater than that of symmetric prostate area (strain ratio >2), targeted biopsy was used; which was followed by an ultrasound-guided 8- or 10-core systematic biopsy (regardless of sonoelastography-indicated sites) as a reference point. Results The mean age of patients was 69 years. PSA serum levels ranged between 1.02 and 885 ng/dl. The mean prostate volume was 62 ml (19–149 ml). Prostate cancer was found in 39 out of 84 individuals. Statistically significant differences in strain ratios between cancers and benign lesions were shown. Sonoelastography guided biopsy revealed 30 lesions – overall sensitivity 77% (sensitivity of the method – 81%). Sonoelastographic sensitivity increased depending on cancer stage according to the Gleason grading system: 6–60%, 7–75%, 8–83%, 9/10–100%. The estimated sensitivity of systematic biopsy was 92%. Conclusions Sonoelastography shows higher diagnostic sensitivity in prostate cancer diagnostics compared to conventional imaging techniques, i.e. grey-scale TRUS, Doppler ultrasound. It allows to reduce the number of collected tissue cores, and thus limit the incidence of complications as well as the costs involved. Sonoelastography using the determination of compressibility ratio for symmetrical prostatic regions may prove useful in the detection of clinically significant prostate cancer. PMID:26674065
Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K
2016-05-01
The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Barbieri, Raquel Rodrigues; Sales, Anna Maria; Hacker, Mariana Andrea; Nery, José Augusto da Costa; Duppre, Nádia Cristina; Machado, Alice de Miranda; Moraes, Milton Ozório; Sarno, Euzenir Nunes
2016-10-01
We evaluated the profile of patients referred to the Fiocruz Outpatient Clinic, a reference center for the diagnosis and treatment of leprosy in Rio de Janeiro, RJ, and analyzed the origins and outcomes of these referrals. This is an observational retrospective study based on information collected from the Leprosy Laboratory database at Fiocruz, Rio de Janeiro, RJ, Brazil. A total of 1,845 suspected leprosy cases examined at the reference center between 2010 and 2014 were included. The originating health service referrals and diagnostic outcomes were analyzed as well as the clinical and epidemiological data of patients diagnosed with leprosy. Our data show that the profile of the patients treated at the Clinic has changed in recent years. There was an increase in both the proportion of patients with other skin diseases and those who had visited only one health service prior to our Clinic. Among the total 1,845 cases analyzed, the outcomes of 1,380 were linked to other diseases and, in 74% of these cases, a biopsy was not necessary to reach a diagnostic conclusion. A decrease in new leprosy case detection among our patients was also observed. Yet, among the leprosy patients, 40% had some degree of disability at diagnosis. The results of the present study demonstrated the importance of referral centers in support of basic health services within the decentralization strategy. But, the success of the program depends on the advent of new developmental tools to augment diagnostic accuracy for leprosy. However, it should be emphasized that for new diagnostic methods to be developed, a greater commitment on the part of the health care system regarding research is urgently needed.
Assessment of medical practitioners' knowledge of fibromyalgia in Saudi Arabia.
Kaki, Abdullah Mohammad; Hazazi, Abdulaziz A
2018-01-01
Fibromyalgia (FM), a relatively common disease, is difficult to diagnose owing to its subjective symptoms and poor knowledge among medical practitioners. The purpose of this study was to assess the knowledge regarding FM among medical practitioners in Saudi Arabia and the need for educational programs at the undergraduate level. An online survey was administered to physicians, nurses, and technologist/technicians in different regions of the country. Responses were obtained from 104 medical practitioners. Knowledge regarding FM including clinical symptoms, diagnosis, and treatment was assessed. Only 26% of the respondents reported that FM was part of their undergraduate curriculum, and only 8.7% attended educational programs about FM. (Approximately 50% of the medical practitioners either referred FM patients to unrelated specialty or did not know whom to refer these patients to). Only 33.7% of the respondents were familiar with the diagnostic criteria. Physiotherapy (69.4%) and pharmacological treatment (63.9%) were predominantly reported as the appropriate treatment. Knowledge regarding FM among medical practitioners in Saudi Arabia is poor. Further education at the undergraduate level is needed to improve knowledge and avoid delays in diagnosis and treatment.
Irregular analytical errors in diagnostic testing - a novel concept.
Vogeser, Michael; Seger, Christoph
2018-02-23
In laboratory medicine, routine periodic analyses for internal and external quality control measurements interpreted by statistical methods are mandatory for batch clearance. Data analysis of these process-oriented measurements allows for insight into random analytical variation and systematic calibration bias over time. However, in such a setting, any individual sample is not under individual quality control. The quality control measurements act only at the batch level. Quantitative or qualitative data derived for many effects and interferences associated with an individual diagnostic sample can compromise any analyte. It is obvious that a process for a quality-control-sample-based approach of quality assurance is not sensitive to such errors. To address the potential causes and nature of such analytical interference in individual samples more systematically, we suggest the introduction of a new term called the irregular (individual) analytical error. Practically, this term can be applied in any analytical assay that is traceable to a reference measurement system. For an individual sample an irregular analytical error is defined as an inaccuracy (which is the deviation from a reference measurement procedure result) of a test result that is so high it cannot be explained by measurement uncertainty of the utilized routine assay operating within the accepted limitations of the associated process quality control measurements. The deviation can be defined as the linear combination of the process measurement uncertainty and the method bias for the reference measurement system. Such errors should be coined irregular analytical errors of the individual sample. The measurement result is compromised either by an irregular effect associated with the individual composition (matrix) of the sample or an individual single sample associated processing error in the analytical process. Currently, the availability of reference measurement procedures is still highly limited, but LC-isotope-dilution mass spectrometry methods are increasingly used for pre-market validation of routine diagnostic assays (these tests also involve substantial sets of clinical validation samples). Based on this definition/terminology, we list recognized causes of irregular analytical error as a risk catalog for clinical chemistry in this article. These issues include reproducible individual analytical errors (e.g. caused by anti-reagent antibodies) and non-reproducible, sporadic errors (e.g. errors due to incorrect pipetting volume due to air bubbles in a sample), which can both lead to inaccurate results and risks for patients.
David, Solange Gonçalves; Lovero, Kathryn L; Pombo March, Maria de Fátima B; Abreu, Thalita G; Ruffino Netto, Antonio; Kritski, Afranio L; Sant'Anna, Clemax C
2017-06-01
The diagnosis of pediatric tuberculosis (TB) presents many challenges, and is further complicated in HIV-infected patients. While many diagnostic systems have been proposed, there is no pediatric TB diagnosis gold standard. The outcomes of four TB diagnostic systems in HIV-infected children were compared in this study. A retrospective cohort study was conducted at a TB/HIV reference hospital in Rio de Janeiro. HIV-infected pediatric patients evaluated for TB from 1998 to 2010 were reassessed using four diagnostic systems: Kenneth Jones, 1969; Tidjani, 1986; Ben Marais, 2006; Brazilian Ministry of Health, 2010. Results were compared to standardized diagnoses made by an expert panel of physicians. Of the 121 patients in the study cohort, the expert panel diagnosed 64 as TB and 57 as not TB cases. The Tidjani system showed the highest diagnostic accuracy, with and without the inclusion of microbiological data. The Tidjani and Kenneth Jones systems produced fewer false-positives, and the Ben Marais and Ministry of Health fewer false-negatives. Across systems, there was little agreement between TB diagnoses. In HIV-infected pediatric patients, the Ben Marais and Ministry of Health systems are useful for TB diagnostic screening, whereas the Tidjani and Kenneth Jones systems are best used in a reference center setting. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Diagnosis of condensation-induced waterhammer: Case studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izenson, M.G.; Rothe, P.H.; Wallis, G.B.
1988-10-01
This guidebook provides reference material and diagnostic procedures concerning condensation-induced waterhammer in nuclear power plants. Condensation-induced waterhammer is the most damaging form of waterhammer, and its diagnosis is complicated by the complex nature of the underlying phenomena. In Volume 1, the guidebook groups condensation-induced waterhammers into five event classes which have similar phenomena and levels of damage. Diagnostic guidelines focus on locating the event center where condensation and slug acceleration take place. Diagnosis is described in three stages: an initial assessment, detailed evaluation and final confirmation. Graphical scoping analyses are provided to evaluate whether an event from one of themore » event classes could have occurred at the event center. Examples are provided for each type of waterhammer. Special instructions are provided for walking down damaged piping and evaluating damage due to waterhammer. To illustrate the diagnostic methods and document past experience, six case studies have been compiled in Volume 2. These case studies, based on actual condensation-induced waterhammer events at nuclear plants, present detailed data and work through the event diagnosis using the tools introduced in the first volume. 20 refs., 21 figs., 6 tabs.« less
Diagnosis of condensation-induced waterhammer: Methods and background
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izenson, M.G.; Rothe, P.H.; Wallis, G.B.
This guidebook provides reference material and diagnostic procedures concerning condensation-induced waterhammer in nuclear power plants. Condensation-induced waterhammer is the most damaging form of waterhammer and its diagnosis is complicated by the complex nature of the underlying phenomena. In Volume 1, the guidebook groups condensation-induced waterhammers into five event classes which have similar phenomena and levels of damage. Diagnostic guidelines focus on locating the event center where condensation and slug acceleration take place. Diagnosis is described in three stages: an initial assessment, detailed evaluation and final confirmation. Graphical scoping analyses are provided to evaluate whether an event from one of themore » event classes could have occurred at the event center. Examples are provided for each type of waterhammer. Special instructions are provided for walking down damaged piping and evaluating damage due to waterhammer. To illustrate the diagnostic methods and document past experience, six case studies have been compiled in Volume 2. These case studies, based on actual condensation-induced waterhammer events at nuclear plants, present detailed data and work through the event diagnosis using the tools introduced in the first volume. 65 figs., 8 tabs.« less
Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
2011-01-01
Background: New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. Methods: We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. Results: We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). Conclusions: To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further investigate other determinants of diagnostic yield. PMID:21659432
Mens, Petra F; Matelon, Raphael J; Nour, Bakri Y M; Newman, Dave M; Schallig, Henk D F H
2010-07-19
This study describes the laboratory evaluation of a novel diagnostic platform for malaria. The Magneto Optical Test (MOT) is based on the bio-physical detection of haemozoin in clinical samples. Having an assay time of around one minute, it offers the potential of high throughput screening. Blood samples of confirmed malaria patients from different regions of Africa, patients with other diseases and healthy non-endemic controls were used in the present study. The samples were analysed with two reference tests, i.e. an histidine rich protein-2 based rapid diagnostic test (RDT) and a conventional Pan-Plasmodium PCR, and the MOT as index test. Data were entered in 2 x 2 tables and analysed for sensitivity and specificity. The agreement between microscopy, RDT and PCR and the MOT assay was determined by calculating Kappa values with a 95% confidence interval. The observed sensitivity/specificity of the MOT test in comparison with clinical description, RDT or PCR ranged from 77.2 - 78.8% (sensitivity) and from 72.5 - 74.6% (specificity). In general, the agreement between MOT and the other assays is around 0.5 indicating a moderate agreement between the reference and the index test. However, when RDT and PCR are compared to each other, an almost perfect agreement can be observed (k = 0.97) with a sensitivity and specificity of >95%. Although MOT sensitivity and specificity are currently not yet at a competing level compared to other diagnostic test, such as PCR and RDTs, it has a potential to rapidly screen patients for malaria in endemic as well as non-endemic countries.
Iglesias, Nuria; Subirats, Mercedes; Trevisi, Patricia; Ramírez-Olivencia, Germán; Castán, Pablo; Puente, Sabino; Toro, Carlos
2014-07-01
Microscopy and rapid diagnostic tests (RDTs) are the techniques commonly used for malaria diagnosis but they are usually insensitive at very low levels of parasitemia. Nested PCR is commonly used as a reference technique in the diagnosis of malaria due to its high sensitivity and specificity. However, it is a cumbersome assay only available in reference centers. We evaluated a new nested PCR-based assay, BIOMALAR kit (Biotools B&M Labs, Madrid, Spain) which employs ready-to-use gelled reagents and allows the identification of the main four species of Plasmodium. Blood samples were obtained from patients with clinical suspicion of malaria. A total of 94 subjects were studied. Fifty-two (55.3%) of them were malaria-infected subjects corresponding to 48 cases of Plasmodium falciparum, 1 Plasmodium malariae, 2 Plasmodium vivax, and 1 Plasmodium ovale. The performance of the BIOMALAR test was compared with microscopy, rapid diagnostic test (RDT) (BinaxNOW® Malaria) and real-time quantitative PCR (qPCR). The BIOMALAR test showed a sensitivity of 98.1% (95% confidence interval [CI], 89.7-100), superior to microscopy (82.7% [95% CI, 69.7-91.8]) and RDT (94.2% [95% CI, 84.1-98.8]) and similar to qPCR (100% [95% CI, 93.2-100]). In terms of specificity, the BIOMALAR assay showed the same value as microscopy and qPCR (100% [95% CI, 93.2-100]). Nine subjects were submicroscopic carriers of malaria. The BIOMALAR test identified almost all of them (8/9) in comparison with RDT (6/9) and microscopy (0/9). In conclusion, the BIOMALAR is a PCR-based assay easy to use with an excellent performance and especially useful for diagnosis submicroscopic malaria.
Zhang, Xue; Xiao, Yang; Zeng, Jie; Qiu, Weibao; Qian, Ming; Wang, Congzhi; Zheng, Rongqin; Zheng, Hairong
2014-01-01
To develop and evaluate a computer-assisted method of quantifying five-point elasticity scoring system based on ultrasound real-time elastography (RTE), for classifying benign and malignant breast lesions, with pathologic results as the reference standard. Conventional ultrasonography (US) and RTE images of 145 breast lesions (67 malignant, 78 benign) were performed in this study. Each lesion was automatically contoured on the B-mode image by the level set method and mapped on the RTE image. The relative elasticity value of each pixel was reconstructed and classified into hard or soft by the fuzzy c-means clustering method. According to the hardness degree inside lesion and its surrounding tissue, the elasticity score of the RTE image was computed in an automatic way. Visual assessments of the radiologists were used for comparing the diagnostic performance. Histopathologic examination was used as the reference standard. The Student's t test and receiver operating characteristic (ROC) curve analysis were performed for statistical analysis. Considering score 4 or higher as test positive for malignancy, the diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 93.8% (136/145), 92.5% (62/67), 94.9% (74/78), 93.9% (62/66), and 93.7% (74/79) for the computer-assisted scheme, and 89.7% (130/145), 85.1% (57/67), 93.6% (73/78), 92.0% (57/62), and 88.0% (73/83) for manual assessment. Area under ROC curve (Az value) for the proposed method was higher than the Az value for visual assessment (0.96 vs. 0.93). Computer-assisted quantification of classical five-point scoring system can significantly eliminate the interobserver variability and thereby improve the diagnostic confidence of classifying the breast lesions to avoid unnecessary biopsy. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Viardot, Alexander; Huber, Peter; Puder, Jardena J; Zulewski, Henryk; Keller, Ulrich; Müller, Beat
2005-10-01
Nighttime salivary cortisol (NSC) has been suggested to be a useful diagnostic test for Cushing's syndrome (CS). In the absence of published data on its day-to-day variability, we assessed the reproducibility of NSC by repeated measurements in healthy volunteers. Its diagnostic performance was compared with 24-h urinary free cortisol (UFC) and 1 mg overnight dexamethasone suppression test in 12 patients with CS, 20 healthy volunteers, 14 referred patients in which CS was excluded or not firmly established, 16 obese patients, and 20 women in late pregnancy. NSC showed a superior reproducibility in healthy volunteers with a low day-to-day variability as reflected by an intraclass correlation coefficient of 0.78. The receiver operating characteristic curve-estimated cutoff of 6.1 nmol/liter (0.22 microg/dl) demonstrated a sensitivity and specificity of 100% (area under the receiver operating characteristic curve, 1.0; 95% confidence interval, 0.94-1.0) in the diagnosis of CS. NSC, 24-h UFC [after adjusting the local laboratory cutoff to 504 nmol/d (183 microg/d)], and the urinary cortisol/creatinine ratio showed a tendency to be superior to 1 mg dexamethasone suppression test in correctly identifying CS. In late pregnancy, the preserved diurnal variation at a higher level of salivary cortisol reduced the specificity of NSC to 75%. Based on its remarkable reproducibility, easy noninvasive nature, and at least similar diagnostic performance, NSC appears to be a preferable alternative to 24-h UFC as a first-line screening test for CS. The cutoff values of NSC, 24-h UFC, and urinary cortisol/creatinine ratio have to be carefully adjusted using assay and center-specific reference ranges of sufficiently large populations.
Shipitsyna, E; Zolotoverkhaya, E; Hjelmevoll, S O; Maximova, A; Savicheva, A; Sokolovsky, E; Skogen, V; Domeika, M; Unemo, M
2009-11-01
In Russia, laboratory diagnosis of gonorrhoea has been mainly based on microscopy only and, in some settings, relatively rare suboptimal culturing. In recent years, Russian developed and manufactured nucleic acid amplification tests (NAAT) have been implemented for routine diagnosis of Neisseria gonorrhoeae. However, these NAATs have never been validated to any international well-recognized diagnostic NAAT. This study aims to evaluate the performance characteristics of six Russian NAATs for N. gonorrhoeae diagnostics. In total, 496 symptomatic patients were included. Five polymerase chain reaction (PCR) assays and one real-time nucleic acid sequence based amplification (NASBA) assay, developed by three Russian companies, were evaluated on urogenital samples, i.e. cervical and first voided urine (FVU) samples from females (n = 319), urethral and FVU samples from males (n = 127), and extragenital samples, i.e. rectal and pharyngeal samples, from 50 additional female patients with suspicion of gonorrhoea. As reference method, an international strictly validated real-time porA pseudogene PCR was applied. The prevalence of N. gonorrhoeae was 2.7% and 16% among the patients providing urogenital and extragenital samples, respectively. The Russian NAATs and the reference method displayed high level of concordance (99.4-100%). The sensitivities, specificities, positive predictive values and negative predictive values of the Russian tests in different specimens were 66.7-100%, 100%, 100%, and 99.4-100%, respectively. Russian N. gonorrhoeae diagnostic NAATs comprise relatively good performance characteristics. However, larger studies are crucial and, beneficially, the Russian assays should also be evaluated to other international highly sensitive and specific, and ideally Food and Drug Administration approved, NAATs such as Aptima Combo 2 (Gen-Probe).
An Italian multicentre validation study of the coma recovery scale-revised.
Estraneo, A; Moretta, P; De Tanti, A; Gatta, G; Giacino, J T; Trojano, L
2015-10-01
Rate of misdiagnosis of disorders of consciousness (DoC) can be reduced by employing validated clinical diagnostic tools, such as the Coma Recovery Scale-Revised (CRS-R). An Italian version of the CRS-R has been recently developed, but its applicability across different clinical settings, and its concurrent validity and diagnostic sensitivity have not been estimated yet. To perform a multicentre validation study of the Italian version of the Coma Recovery Scale-Revised (CRS-R). Analysis of inter-rater reliability, concurrent validity and diagnostic sensitivity of the scale. One Intensive Care Unit, 8 Post-acute rehabilitation centres and 2 Long-term facilities Twenty-seven professionals (physicians, N.=11; psychologists, N.=5; physiotherapists, N.=3; speech therapists, N.=6; nurses, N.=2) from 11 Italian Centres. CRS-R and Disability Rating Scale (DRS) applied to 122 patients with clinical diagnosis of Vegetative State (VS) or Minimally Conscious State (MCS). CRS-R has good-to-excellent inter-rater reliability for all subscales, particularly for the communication subscale. The Italian version of the CRS-R showed a high sensitivity and specificity in detecting MCS with reference to clinical consensus diagnosis. The CRS-R showed good concurrent validity with the Disability Rating Scale, which had very low specificity with reference to clinical consensus diagnosis. The Italian version of the CRS-R is a valid scale for use from the sub-acute to chronic stages of DoC. It can be administered reliably by all members of the rehabilitation team with different specialties, levels of experience and settings. The present study promote use of the Italian version of the CRS-R to improve diagnosis of DoC patients, and plan tailored rehabilitation treatment.
Mayoral, Víctor; Pérez-Hernández, Concepción; Muro, Inmaculada; Leal, Ana; Villoria, Jesús; Esquivias, Ana
2018-04-27
Based on the clear neuroanatomical delineation of many neuropathic pain (NP) symptoms, a simple tool for performing a short structured clinical encounter based on the IASP diagnostic criteria was developed to identify NP. This study evaluated its accuracy and usefulness. A case-control study was performed in 19 pain clinics within Spain. A pain clinician used the experimental screening tool (the index test, IT) to assign the descriptions of non-neuropathic (nNP), non-localized neuropathic (nLNP), and localized neuropathic (LNP) to the patients' pain conditions. The reference standard was a formal clinical diagnosis provided by another pain clinician. The accuracy of the IT was compared with that of the Douleur Neuropathique en 4 questions (DN4) and the Leeds Assessment of Neuropathic Signs and Symptoms (LANSS). Six-hundred and sixty-six patients were analyzed. There was a good agreement between the IT and the reference standard (kappa =0.722). The IT was accurate in distinguishing between LNP and nLNP (83.2% sensitivity, 88.2% specificity), between LNP and the other pain categories (nLNP + nNP) (80.0% sensitivity, 90.7% specificity), and between NP and nNP (95.5% sensitivity, 89.1% specificity). The accuracy in distinguishing between NP and nNP was comparable with that of the DN4 and the LANSS. The IT took a median of 10 min to complete. A novel instrument based on an operationalization of the IASP criteria can not only discern between LNP and nLNP, but also provide a high level of diagnostic certainty about the presence of NP after a short clinical encounter.
Mental health issues among college students: who gets referred for psychopharmacology evaluation?
Kirsch, Daniel J; Doerfler, Leonard A; Truong, Debbie
2015-01-01
To describe diagnostic and psychotropic medication prescription characteristics among college students referred by college counseling centers for psychopharmacologic evaluation. Participants were 540 college students referred by 6 college counseling centers in Massachusetts between November 2005 and May 2011. Students completed self-report measures of depression, anxiety, suicidal ideation and attempts, and substance use. Information regarding DSM-IV (Diagnostic and Statistical Manual of Mental Disorders, 4th edition) diagnosis, previous history of medication prescription, and current psychotropic medication(s) prescribed by the consulting psychiatrist was obtained from medical records. Depression, anxiety, and attention-deficit/hyperactivity disorder (ADHD) were the most common psychiatric problems identified in students. Half of these students had been prescribed mediation prior to evaluation. Antidepressant medication was the most frequently prescribed medication. A large proportion of students reported previous thoughts of suicide, and 12% had made at least 1 suicide attempt. Depression, anxiety, and ADHD are common among students referred by college counseling centers for medication evaluation and treatment.
Does Sex Influence the Diagnostic Evaluation of Autism Spectrum Disorder in Adults?
ERIC Educational Resources Information Center
Wilson, C. Ellie; Murphy, Clodagh M.; McAlonan, Grainne; Robertson, Dene M.; Spain, Debbie; Hayward, Hannah; Woodhouse, Emma; Deeley, P. Quinton; Gillan, Nicola; Ohlsen, J. Chris; Zinkstok, Janneke; Stoencheva, Vladimira; Faulkner, Jessica; Yildiran, Hatice; Bell, Vaughan; Hammond, Neil; Craig, Michael C.; Murphy, Declan G. M.
2016-01-01
It is unknown whether sex influences the diagnostic evaluation of autism spectrum disorder, or whether male and female adults within the spectrum have different symptom profiles. This study reports sex differences in clinical outcomes for 1,244 adults (935 males and 309 females) referred for autism spectrum disorder assessment. Significantly, more…
9 CFR 130.14 - User fees for FADDL veterinary diagnostics.
Code of Federal Regulations, 2012 CFR
2012-01-01
... slides or plates Slide 49.00 50.00 51.00 53.00 Reference animal tissues for immunohistochemistry Set 171... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false User fees for FADDL veterinary diagnostics. 130.14 Section 130.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE...
9 CFR 130.14 - User fees for FADDL veterinary diagnostics.
Code of Federal Regulations, 2013 CFR
2013-01-01
... slides or plates Slide 49.00 50.00 51.00 53.00 Reference animal tissues for immunohistochemistry Set 171... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false User fees for FADDL veterinary diagnostics. 130.14 Section 130.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE...
9 CFR 130.14 - User fees for FADDL veterinary diagnostics.
Code of Federal Regulations, 2014 CFR
2014-01-01
... slides or plates Slide 49.00 50.00 51.00 53.00 Reference animal tissues for immunohistochemistry Set 171... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false User fees for FADDL veterinary diagnostics. 130.14 Section 130.14 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE...
Adjusting for partial verification or workup bias in meta-analyses of diagnostic accuracy studies.
de Groot, Joris A H; Dendukuri, Nandini; Janssen, Kristel J M; Reitsma, Johannes B; Brophy, James; Joseph, Lawrence; Bossuyt, Patrick M M; Moons, Karel G M
2012-04-15
A key requirement in the design of diagnostic accuracy studies is that all study participants receive both the test under evaluation and the reference standard test. For a variety of practical and ethical reasons, sometimes only a proportion of patients receive the reference standard, which can bias the accuracy estimates. Numerous methods have been described for correcting this partial verification bias or workup bias in individual studies. In this article, the authors describe a Bayesian method for obtaining adjusted results from a diagnostic meta-analysis when partial verification or workup bias is present in a subset of the primary studies. The method corrects for verification bias without having to exclude primary studies with verification bias, thus preserving the main advantages of a meta-analysis: increased precision and better generalizability. The results of this method are compared with the existing methods for dealing with verification bias in diagnostic meta-analyses. For illustration, the authors use empirical data from a systematic review of studies of the accuracy of the immunohistochemistry test for diagnosis of human epidermal growth factor receptor 2 status in breast cancer patients.
Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon
Parsi, Mansour A; Stevens, Tyler; Vargo, John J
2012-01-01
AIM: To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). METHODS: Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. RESULTS: Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. CONCLUSION: Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation. PMID:22912549
Diagnostic and therapeutic direct peroral cholangioscopy using an intraductal anchoring balloon.
Parsi, Mansour A; Stevens, Tyler; Vargo, John J
2012-08-14
To report our experience using a recently introduced anchoring balloon for diagnostic and therapeutic direct peroral cholangioscopy (DPOC). Consecutive patients referred for diagnostic or therapeutic peroral cholangioscopy were evaluated in a prospective cohort study. The patients underwent DPOC using an intraductal anchoring balloon, which was recently introduced to allow consistent access to the biliary tree with an ultraslim upper endoscope. The device was later voluntarily withdrawn from the market by the manufacturer. Fourteen patients underwent DPOC using the anchoring balloon. Biliary access with an ultraslim upper endoscope was accomplished in all 14 patients. In 12 (86%) patients, ductal access required sphincteroplasty with a 10-mm dilating balloon. Intraductal placement of the ultraslim upper endoscope allowed satisfactory visualization of the biliary mucosa to the level of the confluence of the right and left hepatic ducts in 13 of 14 patients (93%). Therapeutic interventions by DPOC were successfully completed in all five attempted cases (intraductal biopsy in one and DPOC guided laser lithotripsy in four). Adverse events occurred in a patient on immunosuppressive therapy who developed an intrahepatic biloma at the site of the anchoring balloon. This required hospitalization and antibiotics. Repeat endoscopic retrograde cholangiopancreatography 8 wk after the index procedure showed resolution of the biloma. Use of this anchoring balloon allowed consistent access to the biliary tree for performance of diagnostic and therapeutic DPOC distal to the biliary bifurcation.
Treglia, Giorgio; Pagano, Manuela; Fania, Piercarlo; Basso, Maria Eleonora; Fagioli, Franca; Ficola, Umberto
2013-01-01
Background. In this study we retrospectively evaluated if 18F-FDG-PET/CT provided incremental diagnostic information over CI in a group of hepatoblastoma patients performing restaging. Procedure. Nine patients (mean age: 5.9 years; range: 3.1–12 years) surgically treated for hepatoblastoma were followed up by clinical examination, serum α-FP monitoring, and US. CI (CT or MRI) and PET/CT were performed in case of suspicion of relapse. Fine-needle aspiration biopsies (FNAB) were carried out for final confirmation if the results of CI, PET/CT, and/or α-FP levels were suggestive of relapse. PET/CT and CI findings were analyzed for comparison purposes, using FNAB as reference standard. Results. α-FP level was suggestive of disease recurrence in 8/9 patients. Biopsy was performed in 8/9 cases. CI and PET/CT resulted to be concordant in 5/9 patients (CI identified recurrence of disease, but 18F-FDG-PET/CT provided a better definition of disease extent); in 4/9 cases, CI diagnostic information resulted in negative findings, whereas PET/CT correctly detected recurrence of disease. 18F-FDG-PET/CT showed an agreement of 100% (8/8) with FNAB results. Conclusions. 18F-FDG-PET/CT scan seems to better assess HB patients with respect to CI and may provide incremental diagnostic value in the restaging of this group of patients. PMID:24063012
Verdugo, C; El Masry, I; Makonnen, Y; Hannah, H; Unger, F; Soliman, M; Galal, S; Lubroth, J; Grace, D
2016-12-01
Many developing countries lack sufficient resources to conduct animal disease surveillance. In recent years, participatory epidemiology has been used to increase the cover and decrease the costs of surveillance. However, few diagnostic performance assessments have been carried out on participatory methods. The objective of the present study was to estimate the diagnostic performance of practitioners working for the Community-Based Animal Health and Outreach (CAHO) program, which is a participatory disease surveillance system for the detection of highly pathogenic avian influenza outbreaks in Egypt. CAHO practitioners' diagnostic assessment of inspected birds was compared with real-time reverse-transcriptase polymerase chain reaction (RRT-PCR) test results at the household level. Diagnostic performance was estimated directly from two-by-two tables using RRT-PCR as a reference test in two different scenarios. In the first scenario, only results from chickens were considered. In the second scenario, results for all poultry species were analyzed. Poultry flocks in 916 households located in 717 villages were inspected by CAHO practitioners, who collected 3458 bird samples. In the first scenario, CAHO practitioners presented sensitivity (Se) and specificity (Sp) estimates of 40% (95% confidence interval [CI]: 21%-59%) and 92% (95% CI: 91%-94%), respectively. In the second scenario, diagnostic performance estimates were Se = 47% (95% CI: 29%-65%) and Sp = 88% (95% CI: 86%-90%). A significant difference was observed only between Sp estimates (P < 0.01). Practitioners' diagnostics and RRT-PCR results were in very poor agreement with kappa values of 0.16 and 0.14 for scenarios 1 and 2, respectively. However, the use of a broad case definition, the possible presence of immunity against the virus in replacement birds, and the low prevalence observed during the survey would negatively affect the practitioners' performance.
Wyland, Matthew; Applequist, Lee; Bolowsky, Erin; Klingensmith, Heather; Virag, Isaac
2016-01-01
Background Plantar fasciitis (PF) is the most common cause of heel pain that affects 10% of the general population, whether living an athletic or sedentary lifestyle. The most frequent mechanism of injury is an inflammatory response that is caused by repetitive micro trauma. Many techniques are available to diagnose PF, including the use of ultrasonography (US). Purpose The purpose of this study is to systematically review and appraise previously published articles published between the years 2000 and 2015 that evaluated the effectiveness of using US in the process of diagnosing PF, as compared to alternative diagnostic methods. Methods A total of eight databases were searched to systematically review scholarly (peer reviewed) diagnostic and intervention articles pertaining to the ability of US to diagnose PF. Results Using specific key words the preliminary search yielded 264 articles, 10 of which were deemed relevant for inclusion in the study. Two raters independently scored each article using the 15 point modified QUADAS scale. Discussion Six studies compared the diagnostic efficacy of US to another diagnostic technique to diagnose PF, and four studies focused on comparing baseline assessment of plantar fascia before subsequent intervention. The most notable US outcomes measured were plantar fascia thickness, enthesopathy, and hypoechogenicity. Conclusion US was found to be accurate and reliable compared to alternative reference standards like MRI in the diagnosis of PF. The general advantages of US (e.g. cost efficient, ease of administration, non-invasive, limited contraindications) make it a superior diagnostic modality in the diagnosis of PF. US should be considered in rehabilitation clinics to effectively diagnose PF and to accurately monitor improvement in the disease process following rehabilitation interventions. Level of Evidence 1A PMID:27757279
Role of chromatography in the development of Standard Reference Materials for organic analysis.
Wise, Stephen A; Phinney, Karen W; Sander, Lane C; Schantz, Michele M
2012-10-26
The certification of chemical constituents in natural-matrix Standard Reference Materials (SRMs) at the National Institute of Standards and Technology (NIST) can require the use of two or more independent analytical methods. The independence among the methods is generally achieved by taking advantage of differences in extraction, separation, and detection selectivity. This review describes the development of the independent analytical methods approach at NIST, and its implementation in the measurement of organic constituents such as contaminants in environmental materials, nutrients and marker compounds in food and dietary supplement matrices, and health diagnostic and nutritional assessment markers in human serum. The focus of this review is the important and critical role that separation science techniques play in achieving the necessary independence of the analytical steps in the measurement of trace-level organic constituents in natural matrix SRMs. Published by Elsevier B.V.
Iwen, K A; Lehnert, H
2018-05-17
During pregnancy thyroid hormones have profound effects on embryonal/fetal development and maternal health. Therefore, thyroid gland disorders should be immediately diagnosed and adequately treated. Pregnancy-specific physiological alterations during pregnancy cause changes in the reference interval for thyroid-stimulating hormone levels and trimester-specific thresholds must be taken into account. This article summarizes the most important diagnostic and therapeutic aspects before, during and after pregnancy. With reference to the period prior to pregnancy, the article discusses iodide supplementation, preconceptional examination of thyroid gland metabolism and the importance of thyroid gland functional disorders for fertility and fulfilling the desire to have children. With a view to the period during pregnancy, the effect of hypothyroxinemia, hypothyroidism, and hyperthyroidism as well as the effects of their treatment on the development of the child are explained. Finally, a description is given of what must be paid attention to in the breast-feeding period and in postpartum thyroiditis.
Braun, Tobias; Grüneberg, Christian; Thiel, Christian
2018-04-01
Routine screening for frailty could be used to timely identify older people with increased vulnerability und corresponding medical needs. The aim of this study was the translation and cross-cultural adaptation of the PRISMA-7 questionnaire, the FRAIL scale and the Groningen Frailty Indicator (GFI) into the German language as well as a preliminary analysis of the diagnostic test accuracy of these instruments used to screen for frailty. A diagnostic cross-sectional study was performed. The instrument translation into German followed a standardized process. Prefinal versions were clinically tested on older adults who gave structured in-depth feedback on the scales in order to compile a final revision of the German language scale versions. For the analysis of diagnostic test accuracy (criterion validity), PRISMA-7, FRAIL scale and GFI were considered the index tests. Two reference tests were applied to assess frailty, either based on Fried's model of a Physical Frailty Phenotype or on the model of deficit accumulation, expressed in a Frailty Index. Prefinal versions of the German translations of each instrument were produced and completed by 52 older participants (mean age: 73 ± 6 years). Some minor issues concerning comprehensibility and semantics of the scales were identified and resolved. Using the Physical Frailty Phenotype (frailty prevalence: 4%) criteria as a reference standard, the accuracy of the instruments was excellent (area under the curve AUC >0.90). Taking the Frailty Index (frailty prevalence: 23%) as the reference standard, the accuracy was good (AUC between 0.73 and 0.88). German language versions of PRISMA-7, FRAIL scale and GFI have been established and preliminary results indicate sufficient diagnostic test accuracy that needs to be further established.
Manifestations, acquisition and diagnostic categories of dental fear in a self-referred population.
Moore, R; Brødsgaard, I; Birn, H
1991-01-01
This study aimed to clarify how manifestations and acquisition relate to diagnostic categories of dental fear in a population of self-referred dental fear patients, since diagnostic criteria specifically related to dental fear have not been validated. DSM III-R diagnostic criteria for phobias were used to compare with four existing dental fear diagnostic categories, referred to as the Seattle system. Subjects were 208 persons with dental fear who were telephone interviewed, of whom a subsample of 155 responded to a mailed Dental Anxiety Scale (DAS), State-Trait Anxiety Inventory and a modified FSS-II Geer Fear Scale (GFS). Personal interviews and a Dental Beliefs Scale of perceived trust and social interaction with dentists were also used to evaluate a subsample of 80 patients selected by sex and high dental fear. Results showed that the majority of the 80 patients (66%), suffered from social embarrassment about their dental fear problem and their inability to do something about it. The largest cause of their fear (84%) was reported to be traumatic dental experiences, especially in childhood (70%). A minority of patients (16%) could not isolate traumatic experiences and had a history of general fearfulness or anxiety. Analysis of GFS data for the 155 subjects showed that fear of snakes and injuries were highest among women; heights and injections among men. Fear of blood was rarely reported. Spearman correlations between GFS individual items and DAS scores indicated functional independence between dental fear and common fears such as blood, injections and enclosures in most cases. Only in specific types of dental fear did these results support Rachman and Lopatka's contention that fears are thought to summate.(ABSTRACT TRUNCATED AT 250 WORDS)
Downs, Sara H; More, Simon J; Goodchild, Anthony V; Whelan, Adam O; Abernethy, Darrell A; Broughan, Jennifer M; Cameron, Angus; Cook, Alasdair J; Ricardo de la Rua-Domenech, R; Greiner, Matthias; Gunn, Jane; Nuñez-Garcia, Javier; Rhodes, Shelley; Rolfe, Simon; Sharp, Michael; Upton, Paul; Watson, Eamon; Welsh, Michael; Woolliams, John A; Clifton-Hadley, Richard S; Parry, Jessica E
2018-05-01
There has been little assessment of the methodological quality of studies measuring the performance (sensitivity and/or specificity) of diagnostic tests for animal diseases. In a systematic review, 190 studies of tests for bovine tuberculosis (bTB) in cattle (published 1934-2009) were assessed by at least one of 18 reviewers using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) checklist adapted for animal disease tests. VETQUADAS (VQ) included items measuring clarity in reporting (n = 3), internal validity (n = 9) and external validity (n = 2). A similar pattern for compliance was observed in studies of different diagnostic test types. Compliance significantly improved with year of publication for all items measuring clarity in reporting and external validity but only improved in four of the nine items measuring internal validity (p < 0.05). 107 references, of which 83 had performance data eligible for inclusion in a meta-analysis were reviewed by two reviewers. In these references, agreement between reviewers' responses was 71% for compliance, 32% for unsure and 29% for non-compliance. Mean compliance with reporting items was 2, 5.2 for internal validity and 1.5 for external validity. The index test result was described in sufficient detail in 80.1% of studies and was interpreted without knowledge of the reference standard test result in only 33.1%. Loss to follow-up was adequately explained in only 31.1% of studies. The prevalence of deficiencies observed may be due to inadequate reporting but may also reflect lack of attention to methodological issues that could bias the results of diagnostic test performance estimates. QUADAS was a useful tool for assessing and comparing the quality of studies measuring the performance of diagnostic tests but might be improved further by including explicit assessment of population sampling strategy. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Using cytology to increase small animal practice revenue.
Hodges, Joanne
2013-11-01
Diagnostic cytology is a useful, noninvasive test with practical foundations in high-quality medicine and applications to practice building. Cytology will generate practice revenue whether assessed in-house or sent to a clinical pathologist. Thorough in-house evaluation is adequate in some cases, but expert opinion is important in many cases. Specimen slides should at least be reviewed in-house for assessment of cellularity and potential artifacts before submission to a reference laboratory. Reference laboratories also provide special stains and advanced molecular diagnostics to help further characterize many neoplastic processes, search for organisms, identify pigments, and address other important aspects of the lesion. Copyright © 2013 Elsevier Inc. All rights reserved.
Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa
2017-11-01
Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.
The role of diagnostic laboratories in support of animal disease surveillance systems.
Zepeda, C
2007-01-01
Diagnostic laboratories are an essential component of animal disease surveillance systems. To understand the occurrence of disease in populations, surveillance systems rely on random or targeted surveys using three approaches: clinical, serological and virological surveillance. Clinical surveillance is the basis for early detection of disease and is usually centered on the detection of syndromes and clinical findings requiring confirmation by diagnostic laboratories. Although most of the tests applied usually perform to an acceptable standard, several have not been properly validated in terms of their diagnostic sensitivity and specificity. Sensitivity and specificity estimates can vary according to local conditions and, ideally, should be determined by national laboratories where the tests are to be applied. The importance of sensitivity and specificity estimates in the design and interpretation of statistically based surveys and risk analysis is fundamental to establish appropriate disease control and prevention strategies. The World Organisation for Animal Health's (OIE) network of reference laboratories acts as centers of expertise for the diagnosis of OIE listed diseases and have a role in promoting the validation of OIE prescribed tests for international trade. This paper discusses the importance of the epidemiological evaluation of diagnostic tests and the role of the OIE Reference Laboratories and Collaborating Centres in this process.
Outcome in obscure gastrointestinal bleeding after capsule endoscopy.
Cañas-Ventura, Alex; Márquez, Lucia; Bessa, Xavier; Dedeu, Josep Maria; Puigvehí, Marc; Delgado-Aros, Sílvia; Ibáñez, Ines Ana; Seoane, Agustin; Barranco, Luis; Bory, Felipe; Andreu, Montserrat; González-Suárez, Begoña
2013-11-16
To investigate the clinical impact of capsule endoscopy (CE) after an obscure gastrointestinal bleeding (OGIB) episode, focusing on diagnostic work-up, follow-up and predictive factors of rebleeding. Patients who were referred to Hospital del Mar (Barcelona, Spain) between 2007 and 2009 for OGIB who underwent a CE were retrospectively analyzed. Demographic data, current treatment with non-steroid anti-inflammtory drugs or anticoagulant drugs, hemoglobin levels, transfusion requirements, previous diagnostic tests for the bleeding episode, as well as CE findings (significant or non-significant), work-up and patient outcomes were analyzed from electronic charts. Variables were compared by χ (2) analysis and Student t test. Risk factors of rebleeding were assessed by Log-rank test, Kaplan-Meier curves and Cox regression model. There were 105 patients [45.7% women, median age of 72 years old (interquartile range 56-79)] and a median follow-up of 326 d (interquartile range 123-641) included in this study. The overall diagnostic yield of CE was 58.1% (55.2% and 63.2%, for patients with occult OGIB and overt OGIB, respectively). In 73 patients (69.5%), OGIB was resolved. Multivariate analysis showed that hemoglobin levels lower than 8 g/dL at diagnosis [hazard ratios (HR) = 2.7, 95%CI: 1.9-6.3], patients aged 70 years and above (HR = 2.1, 95%CI: 1.2-6.1) and significant findings in CE (HR = 2.4, 95%CI: 1.1-5.8) were independent predictors of rebleeding. One third of the patients presented with rebleeding after CE; risk factors were hemoglobin levels < 8 g/dL, age ≥ 70 years or the presence of significant lesions.
Linking measures of adolescent nicotine dependence to a common latent continuum.
Strong, David R; Kahler, Christopher W; Colby, Suzanne M; Griesler, Pamela C; Kandel, Denise
2009-01-01
Using the theoretical model of nicotine dependence (ND) operationalized within the Diagnostic and Statistical Manual of Mental Disorder, fourth Edition (DSM-IV: American Psychiatric [American Psychiatric Association, 1994. Diagnostic and Statistical Manual of Mental Disorders. 4th ed. American Psychiatric Association, Washington, DC]) as a frame of reference, we used methods based in item response theory to link alternative instruments assessing adolescent nicotine dependence severity to a common latent continuum. A multi-ethnic cohort of 6th-10th graders selected from the Chicago Public Schools (CPS) completed five household interviews over 2 years. Youth who reported at least some cigarette use in the last 30 days prior to the interviews at waves W3-W5 completed measures of DSM-IV ND, the Modified Fagertrom Tolerance Questionnaire (mFTQ: Prokhorov et al., 1998) and the Nicotine Dependence Syndrome Scale (NDSS: Shiffman et al., 2004), yielding samples of 253, 241, and 296 respondents at W3-W5, respectively. Confirmatory factor analysis supported a primary dimension of ND. Each instrument's items had complementary and stable relationships to ND across multiple waves of assessment. By aligning symptoms along a common latent ND continuum, we evaluated the consistency of symptoms from different instruments that target similar content. Further, these methods allowed for the examination of the DSM-IV as a continuous index of ND, evaluation of the degree of heterogeneity in levels of ND within groups above and below diagnostic thresholds, and the utility of using the pattern or particular DSM-IV symptoms that led to each score in further differentiating levels of ND. Finally, we examined concurrent validity of the ND continuum and levels of current of smoking at each wave of assessment.
National and international veterinary reference laboratories for infectious diseases.
Edwards, S; Alexander, D
1998-08-01
Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.
Sprunt, Beth; Hoq, Monsurul; Sharma, Umesh; Marella, Manjula
2017-09-20
This study investigated the seeing, hearing and walking questions of the UNICEF/Washington Group Child Functioning Module and the inter-rater reliability between teachers and parents as proxy respondents. Cross-sectional diagnostic accuracy study, two-gate design with representative sampling, comparing Module responses to reference standard assessments for 472 primary aged students in Fiji. Receiver operating characteristic curves were constructed to determine the area under the curve and optimal cut-off points. Areas under the curves ranged from 0.823 to 0.889 indicating "good" diagnostic accuracy. Inter-rater reliability between parent and teacher responses was "good" to "excellent". The optimal cut-off determined by the Youden Index was "some difficulty" however a wide spread of impairment levels were found in this category with most children either having none or substantial impairments. The diagnostic accuracy of the Module seeing, hearing and walking questions appears acceptable with either parents or teachers as proxy respondents. For education systems, use of the cut-off "some difficulty" with accompanying clinical assessment may be important to capture children who require services and learning supports and avoid potentially misleading categorization. Given the high proportion of the sample from special schools research is required to further test the Module in mainstream schools. Implications for rehabilitation Identification of children who are at risk of disability in Fiji is important to enable planning, monitoring and evaluating access to quality inclusive education. The UNICEF/Washington Group Child Functioning Module appears to be a practical and effective tool that can be used by teachers to identify children at risk of disability. Children identified on the UNICEF/Washington Group Child Functioning Module as having "some difficulty" or higher levels of difficulty in relation to vision, hearing or walking should be referred for further assessment and services. Rehabilitation services in Fiji need to prepare for greater numbers of referrals as the Ministry of Education increasingly rolls out the inclusive education policy, which includes identification by schools of children at risk of disability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mahmood, U; Erdi, Y
2015-06-15
Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrixmore » was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.« less
Dowling, Nicki A; Merkouris, Stephanie S; Manning, Victorian; Volberg, Rachel; Lee, Stuart J; Rodda, Simone N; Lubman, Dan I
2018-06-01
Despite the over-representation of people with gambling problems in mental health populations, there is limited information available to guide the selection of brief screening instruments within mental health services. The primary aim was to compare the classification accuracy of nine brief problem gambling screening instruments (two to five items) with a reference standard among patients accessing mental health services. The classification accuracy of nine brief screening instruments was compared with multiple cut-off scores on a reference standard. Eight mental health services in Victoria, Australia. A total of 837 patients were recruited consecutively between June 2015 and January 2016. The brief screening instruments were the Lie/Bet Questionnaire, Brief Problem Gambling Screen (BPGS) (two- to five-item versions), NODS-CLiP, NODS-CLiP2, Brief Biosocial Gambling Screen (BBGS) and NODS-PERC. The Problem Gambling Severity Index (PGSI) was the reference standard. The five-item BPGS was the only instrument displaying satisfactory classification accuracy in detecting any level of gambling problem (low-risk, moderate-risk or problem gambling) (sensitivity = 0.803, specificity = 0.982, diagnostic efficiency = 0.943). Several shorter instruments adequately detected both problem and moderate-risk, but not low-risk, gambling: two three-item instruments (NODS-CLiP, three-item BPGS) and two four-item instruments (NODS-PERC, four-item BPGS) (sensitivity = 0.854-0.966, specificity = 0.901-0.954, diagnostic efficiency = 0.908-0.941). The four-item instruments, however, did not provide any considerable advantage over the three-item instruments. Similarly, the very brief (two-item) instruments (Lie/Bet and two-item BPGS) adequately detected problem gambling (sensitivity = 0.811-0.868, specificity = 0.938-0.943, diagnostic efficiency = 0.933-0.934), but not moderate-risk or low-risk gambling. The optimal brief screening instrument for mental health services wanting to screen for any level of gambling problem is the five-item Brief Problem Gambling Screen (BPGS). Services wanting to employ a shorter instrument or to screen only for more severe gambling problems (moderate-risk/problem gambling) can employ the NODS-CLiP or the three-item BPGS. Services that are only able to accommodate a very brief instrument can employ the Lie/Bet Questionnaire or the two-item BPGS. © 2017 Society for the Study of Addiction.
Diagnosing schistosomiasis: where are we?
Gomes, Luciana Inácia; Enk, Martin Johannes; Rabello, Ana
2014-01-01
In light of the World Health Organization's initiative to extend schistosomiasis morbidity and mortality control programs by including a disease elimination strategy in low endemic settings, this paper reviews diagnostic tools described during the last decades and provide an overview of ongoing efforts in making an efficient diagnostic tool available worldwide. A literature search on PubMed using the search criteria schistosomiasis and diagnosis within the period from 1978 to 2013 was carried out. Articles with abstract in English and that used laboratory techniques specifically developed for the detection of schistosomiasis in humans were included. Publications were categorized according to the methodology applied (parasitological, immunological, or molecular) and stage of development (in house development, limited field, or large scale field testing). The initial research generated 4,535 publications, of which only 643 met the inclusion criteria. The vast majority (537) of the publications focused on immunological techniques; 81 focused on parasitological diagnosis, and 25 focused on molecular diagnostic methods. Regarding the stage of development, 307 papers referred to in-house development, 202 referred to limited field tests, and 134 referred to large scale field testing. The data obtained show that promising new diagnostic tools, especially for Schistosoma antigen and deoxyribonucleic acid (DNA) detection, which are characterized by high sensitivity and specificity, are being developed. In combination with international funding initiatives these tools may result in a significant step forward in successful disease elimination and surveillance, which is to make efficient tests accessible and its large use self-sustainable for control programs in endemic countries.
Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen
2006-01-01
OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726
Can hip abduction and external rotation discriminate sacroiliac joint pain?
Adhia, Divya Bharatkumar; Tumilty, Steve; Mani, Ramakrishnan; Milosavljevic, Stephan; Bussey, Melanie D
2016-02-01
The primary aim of the study is to determine if Hip Abduction and External Rotation (HABER) test is capable of reproducing familiar pain in individuals with low back pain (LBP) of sacroiliac joint (SIJ) origin (SIJ-positive) when compared with LBP of Non-SIJ origin (SIJ-negative). If so, the secondary aim is to determine the diagnostic accuracy of HABER test against the reference standard of pain provocation tests, and to determine which increments of the HABER test has highest sensitivity and specificity for identifying SIJ-positive individuals. Single-blinded diagnostic accuracy study. Participants [n(122)] between ages of 18-50 y, suffering from chronic non-specific LBP (≥3 months) volunteered in the study. An experienced musculoskeletal physiotherapist evaluated and classified participants into either SIJ-positive [n(45)] or SIJ-negative [n(77)], based on reference standard of pain provocation tests [≥3 positive tests = SIJ-positive]. Another musculoskeletal physiotherapist, blinded to clinical groups, evaluated participants for reproduction of familiar pain during each increment (10°, 20°, 30°, 40°, and 50°) of HABER test. The HABER test reproduced familiar pain in SIJ-positive individuals when compared with SIJ-negative individuals [p (0.001), R(2) (0.38), Exp(β) (5.95-10.32)], and demonstrated moderate level of sensitivity (67%-78%) and specificity (71%-72%) for identifying SIJ-positive individuals. Receiver operator curve analysis demonstrated that the HABER increments of ≥30° have the highest sensitivity (83%-100%) and specificity (52%-64%). The HABER test is capable of reproducing familiar pain in SIJ-positive LBP individuals and has moderate levels of sensitivity and specificity for identifying SIJ-positive LBP individuals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tack, Denis; Jahnen, Andreas; Kohler, Sarah; Harpes, Nico; De Maertelaer, Viviane; Back, Carlo; Gevenois, Pierre Alain
2014-01-01
To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. • External support through clinical audit may optimise default parameters of routine CT. • Reduction of 75th percentiles used as reference diagnostic levels is 18-75 %. • The effect of this audit is sustainable over time. • Dose savings through optimisation can be added to those achievable through CT.
Kottou, S; Kollaros, N; Plemmenos, C; Mastorakou, I; Apostolopoulou, S C; Tsapaki, V
2018-02-01
This study aimed to evaluate paediatric radiation doses in a dedicated cardiology hospital, with the objective of characterising patterns in dose variation. The ultimate purpose was to define Local (Institutional) Diagnostic Reference Levels (LDRLs) for different types of paediatric cardiac interventional procedures (IC), according to patient age. From a total of 710 cases performed during three consecutive years, by operators with more than 15 years of experience, the age was noted in only 477 IC procedures. The median values obtained for Fluoroscopy Time (FT), Number of Frames (N) and Kerma Area Product (P KA ) by age range were 5.8 min, 1322 and 2.0 Gy.cm 2 for <1 y; 6.5 min, 1403 and 3.0 Gy.cm 2 for 1 to <5 y; 5.9 min, 950 and 7.0 Gy.cm 2 for 5 to <10 y; 5.7 min, 940 and 14.0 Gy.cm 2 for 10 to <16 y, respectively. A large range of patient dose data is observed, depending greatly on procedure type and patient age. In all age groups the range of median FT, N and P KA values was 3.1-15.8 min, 579-1779 and 1.0-20.8 Gy.cm 2 respectively. Consequently, the definition of LDRLs presents challenges mainly due to the multiple clinical and technical factors affecting the outcome. On the other hand the lack of paediatric IC DRLs makes the identification of good practices more difficult. A consensus is needed on IC procedures nomenclature and grouping in order to allow a common assessment and comparison of doses. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Kang, Keren; Dzakah, Emmanuel E; Huang, Yongping; Xie, Mingquan; Luo, Xiaochun; Li, Wenmei; Wang, Jihua
2015-05-30
The low sensitivity and specificity of Plasmodium falciparum diagnostic tests pose a serious health threat to people living in endemic areas. The objective of the study was to develop a rapid assay for the detection of histidine-rich protein 2 (HRP2) of P. falciparum in whole blood by immunofluorescence chromatographic technology. A total of 1163 positive and negative blood samples were screened. The double-antibody sandwich assay was used to establish the kit and its performance was evaluated for sensitivity, specificity, accuracy, precision, stability, and clinical effectiveness. The cut-off level of detection of the kit was 25 parasites/μl. Common interfering substances in human blood specimens, such as bilirubin, triglyceride and cholesterol had no significant effect on HRP2 antigen detection. The precision of the kit was run with different concentration of standard calibrators and the values were less than 10 %. The performance of this diagnostic kit in the detection of the calibrators has shown that a shelf life of about 12 months gives a more reliable result. Among clinical samples tested, the HRP2 test kit and the reference products had good coincidence rate in a parallel experiment and this test kit had a more sensitive detecting level to the target protein than the reference kits used in this study. The specificity and sensitivity for this test were 99.6 % (800/803) and 99.7 % (1160/1163), respectively. A novel HRP2 immunofluorescence detection method was developed in this study. Overall performance evaluation indicated that the kit has a rapid, high sensitivity and on-spot method for detecting P. falciparum.
Patient doses from fluoroscopically guided cardiac procedures in pediatrics
NASA Astrophysics Data System (ADS)
Martinez, L. C.; Vano, E.; Gutierrez, F.; Rodriguez, C.; Gilarranz, R.; Manzanas, M. J.
2007-08-01
Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for <1 year; 52 for 1-<5 years; 25 for 5-<10 years and 13 for 10-<16 years. Median values of KAP were 1.9, 2.9, 4.5 and 15.4 Gy cm2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers.
Multicenter performance evaluation of a second generation cortisol assay.
Vogeser, Michael; Kratzsch, Jürgen; Ju Bae, Yoon; Bruegel, Mathias; Ceglarek, Uta; Fiers, Tom; Gaudl, Alexander; Kurka, Hedwig; Milczynski, Christoph; Prat Knoll, Cristina; Suhr, Anna C; Teupser, Daniel; Zahn, Ingrid; Ostlund, Richard E
2017-05-01
Untreated disorders of the adrenocortical system, such as Cushing's or Addison's disease, can be fatal, and accurate quantification of a patient's cortisol levels is vital for diagnosis. The objective of this study was to assess the analytical performance of a new fully-automated Elecsys® Cortisol II assay (second generation) to measure cortisol levels in serum and saliva. Four European investigational sites assessed the intermediate precision and reproducibility of the Cortisol II assay (Roche Diagnostics) under routine conditions. Method comparisons of the Cortisol II assay vs. liquid chromatography-tandem mass spectrometry (LC-MS/MS), the gold standard for cortisol measurement, were performed. Cortisol reference ranges from three US sites were determined using samples from self-reported healthy individuals. The coefficients of variation (CVs) for repeatability, intermediate precision, and reproducibility for serum samples were ≤2.6%, ≤5.8%, and ≤9.5%, respectively, and for saliva were ≤4.4% and ≤10.9%, and ≤11.4%, respectively. Agreement between the Cortisol II assay and LC-MS/MS in serum samples was close, with a slope of 1.02 and an intercept of 4.473 nmol/L. Reference range samples were collected from healthy individuals (n=300) and serum morning cortisol concentrations (5-95th percentile) were 166.1-507 nmol/L and afternoon concentrations were 73.8-291 nmol/L. Morning, afternoon, and midnight saliva concentrations (95th percentile) were 20.3, 6.94, and 7.56 nmol/L, respectively. The Cortisol II assay had good precision over the entire measuring range and had excellent agreement with LC-MS/MS. This test was found suitable for routine diagnostic application and will be valuable for the diagnosis of adrenocortical diseases.
Zhang, Yang; Xiao, Xiong; Zhang, Junting; Gao, Zhixian; Ji, Nan; Zhang, Liwei
2017-06-01
To evaluate the diagnostic accuracy of routine blood examinations and Cerebrospinal Fluid (CSF) lactate level for Post-neurosurgical Bacterial Meningitis (PBM) at a large sample-size of post-neurosurgical patients. The diagnostic accuracies of routine blood examinations and CSF lactate level to distinguish between PAM and PBM were evaluated with the values of the Area Under the Curve of the Receiver Operating Characteristic (AUC -ROC ) by retrospectively analyzing the datasets of post-neurosurgical patients in the clinical information databases. The diagnostic accuracy of routine blood examinations was relatively low (AUC -ROC <0.7). The CSF lactate level achieved rather high diagnostic accuracy (AUC -ROC =0.891; CI 95%, 0.852-0.922). The variables of patient age, operation duration, surgical diagnosis and postoperative days (the interval days between the neurosurgery and examinations) were shown to affect the diagnostic accuracy of these examinations. The variables were integrated with routine blood examinations and CSF lactate level by Fisher discriminant analysis to improve their diagnostic accuracy. As a result, the diagnostic accuracy of blood examinations and CSF lactate level was significantly improved with an AUC -ROC value=0.760 (CI 95%, 0.737-0.782) and 0.921 (CI 95%, 0.887-0.948) respectively. The PBM diagnostic accuracy of routine blood examinations was relatively low, whereas the accuracy of CSF lactate level was high. Some variables that are involved in the incidence of PBM can also affect the diagnostic accuracy for PBM. Taking into account the effects of these variables significantly improves the diagnostic accuracies of routine blood examinations and CSF lactate level. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela
2015-05-15
Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.
Definitions and outlook targeting x-ray exposure of patients in diagnostic imaging
NASA Astrophysics Data System (ADS)
Regulla, Dieter F.
2011-03-01
Computer tomography (CT) is vital and currently irreplaceable in diagnostic radiology. But CT operates with ionizing radiation which may cause cancer or non-cancer diseases in humans. The degree of radiation impact depends on the dose administered by an investigation. And this is the core issue: Even CT exams executed lege artis, administer doses to patients which by magnitude are far beyond the level of hitherto known doses of conventional film-screen techniques. Patients undergoing one or multiple CT examinations, digital angiographies or interventions will be exposed to effective doses between roughly several mSv and several 100 mSv depending on type and frequency of the diagnostic investigations. From the radiation protection point of view, there is therefore the worldwide problem of formulating firm rules for the control of these high-dose investigations, as dose limits can not be established for reasons of the medical benefit. This makes the difference compared with radiation protection for occupationally exposed persons. What remains is "software", namely "justification" and "optimization". Justification requires balancing the interests between the health benefit and the potential harm of an exam which has to be responsibly executed by the physician himself; therefore the radiologists' associations are in the duty to prepare practicable rules for justification. Optimization again needs a cooperative solution, and that is the establishment of reference doses for diagnostic examinations, to be checked by the technical service of the producers' companies. Experts and authorities have been aware of the high-dose dilemma in diagnostic imaging since long. It is time for the reflection of active solutions and their implementation into practice.
Fenske, Wiebke; Quinkler, Marcus; Lorenz, Daniela; Zopf, Kathrin; Haagen, Ulrike; Papassotiriou, Jana; Pfeiffer, Andreas F H; Fassnacht, Martin; Störk, Stefan; Allolio, Bruno
2011-05-01
The water deprivation test (WDT) with direct or indirect measurement of plasma arginine vasopressin (AVP) is the method of choice for the differential diagnosis of the polydipsia-polyuria syndrome. In theory, direct measurement of AVP is highly attractive but is hampered by technical difficulties. The aim of the study was to evaluate the utility of copeptin, a surrogate of AVP secretion, in the diagnostic work-up of the polyuria-polydipsia syndrome and to compare its performance with the current diagnostic standard. In two tertiary referral centers, 20 healthy subjects and 50 patients with polydipsia-polyuria syndrome underwent WDT with measurements of both plasma AVP and copeptin levels. The reference diagnosis was based on clinical information and treatment response. Twenty-two patients (44%) were diagnosed with primary polydipsia, 17 (34%) with partial central diabetes insipidus (DI), nine (18%) with complete central DI, and two (4%) with nephrogenic DI. The indirect WDT led to a correct diagnosis in 35 of 50 patients (70%). The direct WDT with AVP or copeptin measurement correctly diagnosed 23 patients (46%) or 36 patients (72%), respectively. Baseline copeptin values greater than 20 pmol/liter identified patients with nephrogenic DI, and concentrations below 2.6 pmol/liter indicated complete central DI. The ratio between Δ copeptin (0800 to 1600 h) and serum sodium concentration at 1600 h yielded optimal diagnostic accuracy, allowing us to also discern partial central DI from primary polydipsia (sensitivity 86%, and specificity 100%). Copeptin holds promise as a diagnostic tool in the polyuria-polydipsia syndrome, improving significantly the diagnostic accuracy of the direct WDT.
Esser, Peter; Hartung, Tim J; Friedrich, Michael; Johansen, Christoffer; Wittchen, Hans-Ulrich; Faller, Hermann; Koch, Uwe; Härter, Martin; Keller, Monika; Schulz, Holger; Wegscheider, Karl; Weis, Joachim; Mehnert, Anja
2018-06-01
Anxiety in cancer patients may represent a normal psychological reaction. To detect patients with pathological levels, appropriate screeners with established cut-offs are needed. Given that previous research is sparse, we investigated the diagnostic accuracy of 2 frequently used screening tools in detecting generalized anxiety disorder (GAD). We used data of a multicenter study including 2141 cancer patients. Diagnostic accuracy was investigated for the Generalized Anxiety Disorder Screener (GAD-7) and the anxiety module of the Hospital Anxiety and Depression Scale (HADS-A). GAD, assessed with the Composite International Diagnostic Interview for Oncology, served as a reference standard. Overall accuracy was measured with the area under the receiver operating characteristics curve (AUC). The AUC of the 2 screeners were statistically compared. We also calculated accuracy measures for selected cut-offs. Diagnostic accuracy could be interpreted as adequate for both screeners, with an identical AUC of .81 (95% CI: .79-.82). Consequently, the 2 screeners did not differ in their performance (P = .86). The best balance between sensitivity and specificity was found for cut-offs ≥7 (GAD-7) and ≥8 (HADS-A). The officially recommended thresholds for the GAD-7 (≥ 10) and the HADS-A (≥11) showed low sensitivities of 55% and 48%, respectively. The GAD-7 and HADS-A showed AUC of adequate diagnostic accuracy and hence are applicable for GAD screening in cancer patients. Nevertheless, the choice of optimal cut-offs should be carefully evaluated. Copyright © 2018 John Wiley & Sons, Ltd.
Abubakar, I; Irvine, L; Aldus, C F; Wyatt, G M; Fordham, R; Schelenz, S; Shepstone, L; Howe, A; Peck, M; Hunter, P R
2007-09-01
To determine the diagnostic accuracy of tests for the rapid diagnosis of bacterial food poisoning in clinical and public health practice and to estimate the cost-effectiveness of these assays in a hypothetical population in order to inform policy on the use of these tests. Studies evaluating diagnostic accuracy of rapid tests were retrieved using electronic databases and handsearching reference lists and key journals. Hospital laboratories and test manufacturers were contacted for cost data, and clinicians involved in the care of patients with food poisoning were invited to discuss the conclusions of this review using the nominal group technique. A systematic review of the current medical literature on assays used for the rapid diagnosis of bacterial food poisoning was carried out. Specific organisms under review were Salmonella, Campylobacter, Escherichia coli O157, Staphylococcus aureus, Clostridium perfringens and Bacillus cereus. Data extraction was undertaken using standardised data extraction forms. Where a sufficient number of studies evaluating comparable tests were identified, meta-analysis was performed. A decision analytic model was developed, using effectiveness data from the review and cost data from hospitals and manufacturers, which contributed to an assessment of the cost-effectiveness of rapid tests in a hypothetical UK population. Finally, diagnostic accuracy and cost-effectiveness results were presented to a focus group of GPs, microbiologists and consultants in communicable disease control, to assess professional opinion on the use of rapid tests in the diagnosis of food poisoning. Good test performance levels were observed with rapid test methods, especially for polymerase chain reaction (PCR) assays. The estimated levels of diagnostic accuracy using the area under the curve of the summary receiver operating characteristic curve was very high. Indeed, although traditional culture is the natural reference test to use for comparative statistical analysis, on many occasions the rapid test outperforms culture, detecting additional 'truly' positive cases of food-borne illness. The significance of these additional positives requires further investigation. Economic modelling suggests that adoption of rapid tests in combination with routine culture is unlikely to be cost-effective, however, as the cost of rapid technologies decreases; total replacement with rapid technologies may be feasible. Despite the relatively poor quality of reporting of studies evaluating rapid detection methods, the reviewed evidence shows that PCR for Campylobacter, Salmonella and E. coli O157 is potentially very successful in identifying pathogens, possibly detecting more than the number currently reported using culture. Less is known about the benefits of testing for B. cereus, C. perfringens and S. aureus. Further investigation is needed on how clinical outcomes may be altered if test results are available more quickly and at a greater precision than in the current practice of bacterial culture.
Watanabe, Hiroshi; Ishii, Kazunari; Hosono, Makoto; Imabayashi, Etsuko; Abe, Koichiro; Inubushi, Masayuki; Ohno, Kazuko; Magata, Yasuhiro; Ono, Kinya; Kikuchi, Kei; Wagatsuma, Kei; Takase, Tadashi; Saito, Kyoko; Takahashi, Yasuyuki
2016-07-01
The optimization of medical exposure is one of the major issues regarding radiation protection in the world, and The International Committee of Radiological Protection and the International Atomic Energy Agency recommend establishing diagnostic reference levels (DRLs) as tools for dose optimization. Therefore, the development of DRLs based on the latest survey has been required for nuclear medicine-related societies and organizations. This prompted us to conduct a nationwide survey on the actual administered radioactivity to adults for the purpose of developing DRLs in nuclear medicine. A nationwide survey was conducted from November 25, 2014 to January 16, 2015. The questionnaire was sent to all of the 1249 nuclear medicine facilities in Japan, and the responses were collected on a website using an answered form. Responses were obtained from 516 facilities, for a response rate of 41 %. 75th percentile of (99m)Tc-MDP and (99m)Tc-HMDP: bone scintigraphy, (99m)Tc-HM-PAO, (99m)Tc-ECD and (123)I-IMP: cerebral blood flow scintigraphy, (99m)Tc-Tetrofosmin, (99m)Tc-MIBI and (201)Tl-Cl; myocardial perfusion scintigraphy and (18)F-FDG: oncology PET (in-house-produced or delivery) in representative diagnostic nuclear medicine scans were 932, 937, 763, 775, 200, 831, 818, 180, 235 and 252, respectively. More than 90 % of the facilities were within the range of 50 % from the median of these survey results in representative diagnostic nuclear medicine facilities in Japan. Responses of the administered radioactivities recommended by the package insert, texts and guidelines such as 740 MBq ((99m)Tc-MDP and (99m)Tc-HMDP: bone scintigraphy), 740 MBq ((99m)Tc-ECD and (99m)Tc-HM-PAO: cerebral blood flow scintigraphy) and 740 MBq ((99m)Tc-Tetrofosmin and (99m)Tc-MIBI: myocardial perfusion scintigraphy), etc. were numerous. The administered activity of many radiopharmaceuticals of bone scintigraphy ((99m)Tc-MDP and (99m)Tc-HMDP), cerebral blood flow scintigraphy ((99m)Tc-HM-PAO) and myocardial perfusion scintigraphy ((99m)Tc-Tetrofosmin and (99m)Tc-MIBI), etc. were within the range of the EU DRLs and almost none of the administered radioactivity in Japan exceeded the upper limit of SNMMI standard administered radioactivity. This survey indicated that the administered radioactivity in diagnostic nuclear medicine in Japan had been in the convergence zone and nuclear medicine facilities in Japan show a strong tendency to adhere to the texts and guidelines. Furthermore, the administered radioactivities in Japan were within the range of variation of the EU and the SNMMI administered radioactivities.
ERIC Educational Resources Information Center
Devena, Sarah E.; Watkins, Marley W.
2012-01-01
The Wechsler Intelligence Scale for Children-Fourth Edition General Abilities Index and Cognitive Proficiency Index have been advanced as possible diagnostic markers of attention deficit hyperactivity disorder. This hypothesis was tested with a hospital sample with attention deficit hyperactivity disorder (n = 78), a referred but nondiagnosed…
ERIC Educational Resources Information Center
Çil, Emine
2015-01-01
Taking a test generally improves the retention of the material tested. This is a phenomenon commonly referred to as testing effect. The present research investigated whether two-tier diagnostic tests promoted student teachers' conceptual understanding of variables in conducting scientific experiments, which is a scientific process skill. In this…
Rask, Mette Trollund; Ørnbøl, Eva; Rosendal, Marianne; Fink, Per
2017-04-01
The upcoming International Classification of Diseases, 11th Revision for primary care use suggests inclusion of a new diagnostic construct, bodily (di)stress syndrome (BDS), for individuals with medically unexplained symptoms. We aimed to explore the long-term outcome of BDS in health care costs, work disability, and self-rated health. Consecutive patients consulting their family physician for a new health problem were screened for physical and mental symptoms by questionnaires (n = 1785). A stratified subsample was examined with a standardized diagnostic interview (n = 701). Patients with single-organ BDS (n = 124) and multiorgan BDS (n = 35), and a reference group with a family physician-verified medical condition (n = 880) were included. All included patients completed a questionnaire at 3, 12, and 24 months of follow-up. Register data on health care costs and work disability were obtained after 2 and 10 years of follow-up, respectively. Patients with BDS displayed poorer self-rated health and higher illness worry at index consultation and throughout follow-up than the reference group (p ≤ .001). The annual health care costs were higher in the BDS groups (2270 USD and 4066 USD) than in the reference group (1392 USD) (achieved significance level (ASL) ≤ 0.001). Both BDS groups had higher risk of sick leave during the first 2 years of follow-up (RRsingle-organ BDS = 3.0; 95% confidence interval [CI] = 1.8-5.0; RRmultiorgan BDS = 3.4; 95% CI = 1.5-7.5) and substantially higher risk of newly awarded disability pension than the reference group (HRsingle-organ BDS = 4.9; 95% CI = 2.8-8.4; HRmultiorgan BDS = 8.7; 95% CI = 3.7-20.7). Patients with BDS have poor long-term outcome of health care costs, work disability, and subjective suffering. These findings stress the need for adequate recognition and management of BDS.
Rask, Mette Trollund; Ørnbøl, Eva; Rosendal, Marianne; Fink, Per
2017-01-01
ABSTRACT Objective The upcoming International Classification of Diseases, 11th Revision for primary care use suggests inclusion of a new diagnostic construct, bodily (di)stress syndrome (BDS), for individuals with medically unexplained symptoms. We aimed to explore the long-term outcome of BDS in health care costs, work disability, and self-rated health. Methods Consecutive patients consulting their family physician for a new health problem were screened for physical and mental symptoms by questionnaires (n = 1785). A stratified subsample was examined with a standardized diagnostic interview (n = 701). Patients with single-organ BDS (n = 124) and multiorgan BDS (n = 35), and a reference group with a family physician–verified medical condition (n = 880) were included. All included patients completed a questionnaire at 3, 12, and 24 months of follow-up. Register data on health care costs and work disability were obtained after 2 and 10 years of follow-up, respectively. Results Patients with BDS displayed poorer self-rated health and higher illness worry at index consultation and throughout follow-up than the reference group (p ≤ .001). The annual health care costs were higher in the BDS groups (2270 USD and 4066 USD) than in the reference group (1392 USD) (achieved significance level (ASL) ≤ 0.001). Both BDS groups had higher risk of sick leave during the first 2 years of follow-up (RRsingle-organ BDS = 3.0; 95% confidence interval [CI] = 1.8–5.0; RRmultiorgan BDS = 3.4; 95% CI = 1.5–7.5) and substantially higher risk of newly awarded disability pension than the reference group (HRsingle-organ BDS = 4.9; 95% CI = 2.8–8.4; HRmultiorgan BDS = 8.7; 95% CI = 3.7–20.7). Conclusions Patients with BDS have poor long-term outcome of health care costs, work disability, and subjective suffering. These findings stress the need for adequate recognition and management of BDS. PMID:27768649
van Gent, Tiejo; Goedhart, Arnold W; Treffers, Philip D A
2012-01-01
In this study socio-demographic, deafness-related and diagnostic characteristics of hearing impaired children and adolescents referred to a national mental health service for deaf and hard of hearing children and adolescents were examined. Socio-demographic and diagnostic characteristics were compared to corresponding characteristics of hearing referred peers with identified mental health problems. The difference in characteristics between them and hearing referred peers with identified mental health problems was analyzed. A total of 389 deaf and hard of hearing and 3361 hearing children and adolescents was extracted from a database, all first referrals of patients of a center for child and adolescent psychiatry over a 15-year period. With deaf and hard of hearing patients we found higher rates of environmental stress, as indicated by conditions such as more one parent families (38.6% versus 25.8%), and more parents with a low educational level (44.2% versus 31.1%). Moreover, deaf and hard of hearing patients were older at their first referral (10.8 versus 9.4 years) and had higher rates of pervasive developmental disorders (23.7% versus 12.3%) and mental retardation (20.3% versus 3.9%). Within the target group of deaf and hard of hearing patients, most patients were deaf (68.9%; 22.3% was severely hard of hearing), relatively few (13.7%) had a non-syndromal hereditary hearing impairment, and more (21.3%) had a disabling physical health condition, especially those with a pervasive developmental disorder (42.6%). These findings illustrate both the complexity of the problems of deaf and hard of hearing children and adolescents referred to specialist mental health services, and the need for preventive interventions aimed at early recognition. Copyright © 2012 Elsevier Ltd. All rights reserved.
Miller, R A
2010-01-01
The INTERNIST-1/Quick Medical Reference (QMR) diagnostic decision support project spans four decades, from 1971-onward. This paper describes the history of the project and details insights gained of relevance to the general clinical and informatics communities.
Sepulveda, Esteban; Franco, José G; Trzepacz, Paula T; Gaviria, Ana M; Meagher, David J; Palma, José; Viñuelas, Eva; Grau, Imma; Vilella, Elisabet; de Pablo, Joan
2016-05-26
Information on validity and reliability of delirium criteria is necessary for clinicians, researchers, and further developments of DSM or ICD. We compare four DSM and ICD delirium diagnostic criteria versions, which were developed by consensus of experts, with a phenomenology-based natural diagnosis delineated using cluster analysis of delirium features in a sample with a high prevalence of dementia. We also measured inter-rater reliability of each system when applied by two evaluators from distinct disciplines. Cross-sectional analysis of 200 consecutive patients admitted to a skilled nursing facility, independently assessed within 24-48 h after admission with the Delirium Rating Scale-Revised-98 (DRS-R98) and for DSM-III-R, DSM-IV, DSM-5, and ICD-10 criteria for delirium. Cluster analysis (CA) delineated natural delirium and nondelirium reference groups using DRS-R98 items and then diagnostic systems' performance were evaluated against the CA-defined groups using logistic regression and crosstabs for discriminant analysis (sensitivity, specificity, percentage of subjects correctly classified by each diagnostic system and their individual criteria, and performance for each system when excluding each individual criterion are reported). Kappa Index (K) was used to report inter-rater reliability for delirium diagnostic systems and their individual criteria. 117 (58.5 %) patients had preexisting dementia according to the Informant Questionnaire on Cognitive Decline in the Elderly. CA delineated 49 delirium subjects and 151 nondelirium. Against these CA groups, delirium diagnosis accuracy was highest using DSM-III-R (87.5 %) followed closely by DSM-IV (86.0 %), ICD-10 (85.5 %) and DSM-5 (84.5 %). ICD-10 had the highest specificity (96.0 %) but lowest sensitivity (53.1 %). DSM-III-R had the best sensitivity (81.6 %) and the best sensitivity-specificity balance. DSM-5 had the highest inter-rater reliability (K =0.73) while DSM-III-R criteria were the least reliable. Using our CA-defined, phenomenologically-based delirium designations as the reference standard, we found performance discordance among four diagnostic systems when tested in subjects where comorbid dementia was prevalent. The most complex diagnostic systems have higher accuracy and the newer DSM-5 have higher reliability. Our novel phenomenological approach to designing a delirium reference standard may be preferred to guide revisions of diagnostic systems in the future.
Storgaard, H; Mortensen, B; Almdal, T; Laub, M; Tarnow, L
2014-11-01
To investigate the prevalence of symptomatic obstructive sleep apnoea in unselected patients with Type 2 diabetes referred to a tertiary diabetes clinic. In a cross-sectional design, all newly referred patients were offered a stepwise screening for obstructive sleep apnoea with: (1) The Berlin questionnaire; then, if indicative: (2) overnight home monitoring with the ApneaLink™ device. Patients with an apnoea-hypopnoea index ≥ 5/h were offered referral for diagnostic polygraphy and treatment initiation. A total of 200 patients participated (61% men; age 59.6 ± 10.5 years, diabetes duration 8.3 ± 6.3 years and BMI 31.7 ± 6.7 kg/m²). According to the questionnaire, 106 patients showed 'high risk' of obstructive sleep apnoea, and 72 of these were referred to polygraphy based on ApneaLink screening corresponding to a prevalence of symptomatic obstructive sleep apnoea of 39%. Patients with symptomatic obstructive sleep apnoea had significantly higher BMI, poorer glycaemic control and lower plasma HDL cholesterol levels as compared with patients unlikely to have obstructive sleep apnoea. The groups were not different with respect to sex, age, diabetes duration, blood pressure, diabetic complications or medication use. In multiple regression analyses, age, BMI and HDL cholesterol levels were all significant, independent predictors of obstructive sleep apnoea. At least one third of people with Type 2 diabetes referred to a diabetes clinic in Denmark has symptomatic obstructive sleep apnoea. Our data suggest higher age, a compromised plasma lipid profile and a more obese phenotype in patients with Type 2 diabetes who have obstructive sleep apnoea, highlighting the need to focus on screening and treatment of obstructive sleep apnoea in these patients. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.
The Quantitative Science of Evaluating Imaging Evidence.
Genders, Tessa S S; Ferket, Bart S; Hunink, M G Myriam
2017-03-01
Cardiovascular diagnostic imaging tests are increasingly used in everyday clinical practice, but are often imperfect, just like any other diagnostic test. The performance of a cardiovascular diagnostic imaging test is usually expressed in terms of sensitivity and specificity compared with the reference standard (gold standard) for diagnosing the disease. However, evidence-based application of a diagnostic test also requires knowledge about the pre-test probability of disease, the benefit of making a correct diagnosis, the harm caused by false-positive imaging test results, and potential adverse effects of performing the test itself. To assist in clinical decision making regarding appropriate use of cardiovascular diagnostic imaging tests, we reviewed quantitative concepts related to diagnostic performance (e.g., sensitivity, specificity, predictive values, likelihood ratios), as well as possible biases and solutions in diagnostic performance studies, Bayesian principles, and the threshold approach to decision making. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Value of diagnostic imaging for the symptomatic male breast: Can we avoid unnecessary biopsies?
Foo, Eric T; Lee, Amie Y; Ray, Kimberly M; Woodard, Genevieve A; Freimanis, Rita I; Joe, Bonnie N
To review the use of diagnostic breast imaging and outcomes for symptomatic male patients. We retrospectively evaluated 122 males who underwent diagnostic imaging for breast symptoms at our academic center. The majority (94%) of cases had negative or benign imaging, with gynecomastia being the most common diagnosis (78%). There were two malignancies, both of which had positive imaging. Fifteen patients underwent percutaneous biopsy, and over half (53%) were palpation-guided biopsies initiated by the referring clinician despite negative imaging. Diagnostic imaging demonstrated 100% sensitivity and 96% specificity for identifying cancer. Malignancy is rarely a cause of male breast symptoms. Diagnostic breast imaging is useful to establish benignity and avert unnecessary biopsies. Copyright © 2017 Elsevier Inc. All rights reserved.
Azer, Samy A; AlSwaidan, Nourah M; Alshwairikh, Lama A; AlShammari, Jumana M
2015-01-01
Objective To evaluate accuracy of content and readability level of English Wikipedia articles on cardiovascular diseases, using quality and readability tools. Methods Wikipedia was searched on the 6 October 2013 for articles on cardiovascular diseases. Using a modified DISCERN (DISCERN is an instrument widely used in assessing online resources), articles were independently scored by three assessors. The readability was calculated using Flesch-Kincaid Grade Level. The inter-rater agreement between evaluators was calculated using the Fleiss κ scale. Results This study was based on 47 English Wikipedia entries on cardiovascular diseases. The DISCERN scores had a median=33 (IQR=6). Four articles (8.5%) were of good quality (DISCERN score 40–50), 39 (83%) moderate (DISCERN 30–39) and 4 (8.5%) were poor (DISCERN 10–29). Although the entries covered the aetiology and the clinical picture, there were deficiencies in the pathophysiology of diseases, signs and symptoms, diagnostic approaches and treatment. The number of references varied from 1 to 127 references; 25.9±29.4 (mean±SD). Several problems were identified in the list of references and citations made in the articles. The readability of articles was 14.3±1.7 (mean±SD); consistent with the readability level for college students. In comparison, Harrison’s Principles of Internal Medicine 18th edition had more tables, less references and no significant difference in number of graphs, images, illustrations or readability level. The overall agreement between the evaluators was good (Fleiss κ 0.718 (95% CI 0.57 to 0.83). Conclusions The Wikipedia entries are not aimed at a medical audience and should not be used as a substitute to recommended medical resources. Course designers and students should be aware that Wikipedia entries on cardiovascular diseases lack accuracy, predominantly due to errors of omission. Further improvement of the Wikipedia content of cardiovascular entries would be needed before they could be considered a supplementary resource. PMID:26443650
Clinical Assessment of Physical Examination Maneuvers for Rotator Cuff Lesions.
Somerville, Lyndsay E; Willits, Kevin; Johnson, Andrew M; Litchfield, Robert; LeBel, Marie-Eve; Moro, Jaydeep; Bryant, Dianne
2014-08-01
Shoulder pain and disability pose a diagnostic challenge for clinicians owing to the numerous causes that exist. Unfortunately, the evidence in support of most clinical tests is weak or absent. To determine the diagnostic validity of physical examination maneuvers for rotator cuff lesions. Cohort study (diagnosis); Level of evidence, 1. Consecutive shoulder patients recruited for this study were referred to 2 tertiary orthopaedic clinics. A surgeon took a thorough history and indicated his or her certainty about each possible diagnosis. A clinician performed the physical examination for diagnoses where uncertainty remained. Arthroscopy was considered the reference standard for patients who underwent surgery, and MRI with arthrogram was considered the reference for patients who did not. The sensitivity, specificity, and likelihood ratios were calculated to investigate whether combinations of the top tests provided stronger predictions of the presence or absence of disease. There were 139 participants. None of the tests were highly sensitive for diagnosing rotator cuff tears or tendinosis. Tests for subscapularis tears were all highly specific. No optimal combination of tests improved the ability to correctly diagnose rotator cuff tears. Closer analysis revealed the internal rotation and lateral rotation lag sign did not improve the ability to diagnose subscapularis or supraspinatus tears, respectively, although the lateral rotation lag sign demonstrated a discriminatory ability for tear size. No test in isolation is sufficient to diagnose a patient with rotator cuff damage. A combination of tests improves the ability to diagnose damage to the rotator cuff. It is recommended that the internal rotation and lateral rotation lag signs be removed from the gamut of physical examination tests for supraspinatus and subscapularis tears. © 2014 The Author(s).
Evaluation of the OnSite (Pf/Pan) rapid diagnostic test for diagnosis of clinical malaria.
Mohon, Abu Naser; Elahi, Rubayet; Podder, Milka Patracia; Mohiuddin, Khaja; Hossain, Mohammad Sharif; Khan, Wasif A; Haque, Rashidul; Alam, Mohammad Shafiul
2012-12-12
Accurate diagnosis of malaria is an essential prerequisite for proper treatment and drug resistance monitoring. Microscopy is considered the gold standard for malaria diagnosis but has limitations. ELISA, PCR, and Real Time PCR are also used to diagnose malaria in reference laboratories, although their application at the field level is currently not feasible. Rapid diagnostic tests (RDTs) however, have been brought into field operation and widely adopted in recent days. This study evaluates OnSite (Pf/Pan) antigen test, a new RDT introduced by CTK Biotech Inc, USA for malaria diagnosis in a reference setting. Blood samples were collected from febrile patients referred for malaria diagnosis by clinicians. Subjects were included in this study from two different Upazila Health Complexes (UHCs) situated in two malaria endemic districts of Bangladesh. Microscopy and nested PCR were considered the gold standard in this study. OnSite (Pf/Pan) RDT was performed on preserved whole blood samples. In total, 372 febrile subjects were included in this study. Of these subjects, 229 (61.6%) tested positive for Plasmodium infection detected by microscopy and nested PCR. OnSite (Pf/Pan) RDT was 94.2% sensitive (95% CI, 89.3-97.3) and 99.5% specific (95% CI, 97.4-00.0) for Plasmodium falciparum diagnosis and 97.3% sensitive (95% CI, 90.5-99.7) and 98.7% specific (95% CI, 96.6-99.6) for Plasmodium vivax diagnosis. Sensitivity varied with differential parasite count for both P. falciparum and P. vivax. The highest sensitivity was observed in febrile patients with parasitaemia that ranged from 501-1,000 parasites/μL regardless of the Plasmodium species. The new OnSite (Pf/Pan) RDT is both sensitive and specific for symptomatic malaria diagnosis in standard laboratory conditions.
A manifesto for cardiovascular imaging: addressing the human factor†
Fraser, Alan G
2017-01-01
Abstract Our use of modern cardiovascular imaging tools has not kept pace with their technological development. Diagnostic errors are common but seldom investigated systematically. Rather than more impressive pictures, our main goal should be more precise tests of function which we select because their appropriate use has therapeutic implications which in turn have a beneficial impact on morbidity or mortality. We should practise analytical thinking, use checklists to avoid diagnostic pitfalls, and apply strategies that will reduce biases and avoid overdiagnosis. We should develop normative databases, so that we can apply diagnostic algorithms that take account of variations with age and risk factors and that allow us to calculate pre-test probability and report the post-test probability of disease. We should report the imprecision of a test, or its confidence limits, so that reference change values can be considered in daily clinical practice. We should develop decision support tools to improve the quality and interpretation of diagnostic imaging, so that we choose the single best test irrespective of modality. New imaging tools should be evaluated rigorously, so that their diagnostic performance is established before they are widely disseminated; this should be a shared responsibility of manufacturers with clinicians, leading to cost-effective implementation. Trials should evaluate diagnostic strategies against independent reference criteria. We should exploit advances in machine learning to analyse digital data sets and identify those features that best predict prognosis or responses to treatment. Addressing these human factors will reap benefit for patients, while technological advances continue unpredictably. PMID:29029029
Complex interferometry potential in case of sufficiently stable diagnostic system
NASA Astrophysics Data System (ADS)
Kalal, M.
2016-06-01
Classical interferometry is one of the key methods among active optical diagnostics. Its more advanced version, which allows recording and subsequent reconstruction of up to three sets of data using just one data object —a complex interferogram—was developed in the past and became known as complex interferometry. Employing this diagnostics, not only the usual phase shift, but also the amplitude of the probing beam as well as the fringe contrast (leading directly to the phase shift time derivative) can be reconstructed simultaneously from such a complex interferogram. In this paper it will be demonstrated that even in the case of a not particularly good diagnostic beam quality these three quantities can be reconstructed with a high degree of accuracy provided both the diagnostic beam as well as the corresponding optical line feature a reasonable stability. Such stability requirement is important as in an ideal case four shots need to be gradually recorded (one by one): the signal complex interferogram, the reference interferogram as well as the intensity structures of the signal and reference part of the diagnostic beam. Two examples of complex interferograms obtained in experiments will be analyzed: the laser produced plasma (spark in the air) and the high pressure gas jet. A general ray-tracing based iterative algorithm will be outlined in order to increase a precision of the index of refraction spatial profile taking into account refraction effects (omitted in the Abel inversion) and employing the original reconstructed phase shift and amplitude.
Manchikanti, Laxmaiah; Boswell, Mark V; Singh, Vijay; Derby, Richard; Fellows, Bert; Falco, Frank J E; Datta, Sukdeb; Smith, Howard S; Hirsch, Joshua A
2009-01-01
Understanding the neurophysiological basis of chronic spinal pain and diagnostic interventional techniques is crucial in the proper diagnosis and management of chronic spinal pain. Central to the understanding of the structural basis of chronic spinal pain is the provision of physical diagnosis and validation of patient symptomatology. It has been shown that history, physical examination, imaging, and nerve conduction studies in non-radicular or discogenic pain are unable to diagnose the precise cause in 85% of the patients. In contrast, controlled diagnostic blocks have been shown to determine the cause of pain in as many as 85% of the patients. To provide evidence-based clinical practice guidelines for diagnostic interventional techniques. Best evidence synthesis. Strength of evidence was assessed by the U.S. Preventive Services Task Force (USPSTF) criteria utilizing 5 levels of evidence ranging from Level I to III with 3 subcategories in Level II. Diagnostic criteria established by systematic reviews were utilized with controlled diagnostic blocks. Diagnostic criteria included at least 80% pain relief with controlled local anesthetic blocks with the ability to perform multiple maneuvers which were painful prior to the diagnostic blocks for facet joint and sacroiliac joint blocks, whereas for provocation discography, the criteria included concordant pain upon stimulation of the target disc with 2 adjacent discs producing no pain at all. The indicated level of evidence for diagnostic lumbar, cervical, and thoracic facet joint nerve blocks is Level I or II-1. The indicated evidence is Level II-2 for lumbar and cervical discography, whereas it is Level II-3 for thoracic provocation discography. The evidence for diagnostic sacroiliac joint nerve blocks is Level II-2. Level of evidence for selective nerve root blocks for diagnostic purposes is Level II-3. Limitations of this guideline preparation include a continued paucity of literature and conflicts in preparation of systematic reviews and guidelines. These guidelines include the evaluation of evidence for diagnostic interventional procedures in managing chronic spinal pain and recommendations. However, these guidelines do not constitute inflexible treatment recommendations. These guidelines also do not represent a "standard of care."
NASA Astrophysics Data System (ADS)
Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.
2003-07-01
The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.
Pinheiro, Leonardo B; O'Brien, Helen; Druce, Julian; Do, Hongdo; Kay, Pippa; Daniels, Marissa; You, Jingjing; Burke, Daniel; Griffiths, Kate; Emslie, Kerry R
2017-11-07
Use of droplet digital PCR technology (ddPCR) is expanding rapidly in the diversity of applications and number of users around the world. Access to relatively simple and affordable commercial ddPCR technology has attracted wide interest in use of this technology as a molecular diagnostic tool. For ddPCR to effectively transition to a molecular diagnostic setting requires processes for method validation and verification and demonstration of reproducible instrument performance. In this study, we describe the development and characterization of a DNA reference material (NMI NA008 High GC reference material) comprising a challenging methylated GC-rich DNA template under a novel 96-well microplate format. A scalable process using high precision acoustic dispensing technology was validated to produce the DNA reference material with a certified reference value expressed in amount of DNA molecules per well. An interlaboratory study, conducted using blinded NA008 High GC reference material to assess reproducibility among seven independent laboratories demonstrated less than 4.5% reproducibility relative standard deviation. With the exclusion of one laboratory, laboratories had appropriate technical competency, fully functional instrumentation, and suitable reagents to perform accurate ddPCR based DNA quantification measurements at the time of the study. The study results confirmed that NA008 High GC reference material is fit for the purpose of being used for quality control of ddPCR systems, consumables, instrumentation, and workflow.
Tinnitus services in the United Kingdom: a survey of patient experiences.
McFerran, Don; Hoare, Derek J; Carr, Simon; Ray, Jaydip; Stockdale, David
2018-02-13
Tinnitus service provision in the United Kingdom has been investigated from the healthcare provider's perspective demonstrating considerable regional variation particularly regarding availability of psychological treatments. An audiological-based tinnitus service, however, was reportedly available for all tinnitus patients in the UK. The aim of the current study was to define and evaluate nationwide tinnitus healthcare services from the patients' viewpoint. Secondary analyses were performed on data from a 33-item questionnaire provided by the British Tinnitus Association. The questionnaire had been distributed via email and social media. Responses from 937 participants who had or had previously experienced tinnitus were analysed. All but one person had at some time consulted their GP. About one in five received medication in primary care. The majority were referred to secondary care, generally an ENT surgeon or audiovestibular physician; some were referred directly to audiological services. In secondary care the majority underwent audiometric testing and over half underwent MRI scanning. Drugs were prescribed less frequently in secondary care. About one third of patients were referred onwards from diagnostic services in secondary care to receive therapeutic interventions for tinnitus. Therapy was generally delivered by an audiologist or hearing therapist. Just under two fifths of people discharged from secondary care returned to their GP, with most returning within one year. Over a third of this group were re-referred to secondary care. Few patients saw a psychologist (2.6%) though some psychological treatments were delivered by appropriately trained audiologists. Negative counselling from healthcare professionals in both primary and secondary care settings was reported. Although the UK has developed a national service for patients with tinnitus many people find it difficult to access, being blocked at the primary care level or after secondary care diagnostic services. Many of those discharged from secondary care return to their GP within a short space of time and are re-referred to secondary care creating an unsatisfactory and expensive revolving-door pattern of healthcare. Despite psychological treatment modalities having the best evidence base for successful tinnitus management, only a minority of tinnitus patients ever get to meet a psychologist.
Rankin, Nicole M; York, Sarah; Stone, Emily; Barnes, David; McGregor, Deborah; Lai, Michelle; Shaw, Tim; Butow, Phyllis N
2017-05-01
Pathways to lung cancer diagnosis and treatment are complex. International evidence shows significant variations in pathways. Qualitative research investigating pathways to lung cancer diagnosis rarely considers both patient and general practitioner views simultaneously. To describe the lung cancer diagnostic pathway, focusing on the perspective of patients and general practitioners about diagnostic and pretreatment intervals. This qualitative study of patients with lung cancer and general practitioners in Australia used qualitative interviews or a focus group in which participants responded to a semistructured questionnaire designed to explore experiences of the diagnostic pathway. The Model of Pathways to Treatment (the Model) was used as a framework for analysis, with data organized into (1) events, (2) processes, and (3) contributing factors for variations in diagnostic and pretreatment intervals. Thirty participants (19 patients with lung cancer and 11 general practitioners) took part. Nine themes were identified during analysis. For the diagnostic interval, these were: (1) taking patient concerns seriously, (2) a sense of urgency, (3) advocacy that is doctor-driven or self-motivated, and (4) referral: "knowing who to refer to." For the pretreatment interval, themes were: (5) uncertainty, (6) psychosocial support for the patient and family before treatment, and (7) communication among the multidisciplinary team and general practitioners. Two cross-cutting themes were: (8) coordination of care and "handing over" the patient, and (9) general practitioner knowledge about lung cancer. Events were perceived as complex, with diagnosis often being revealed over time, rather than as a single event. Contributing factors at patient, system, and disease levels are described for both intervals. Patients and general practitioners expressed similar themes across the diagnostic and pretreatment intervals. Significant improvements could be made to health systems to facilitate better patient and general practitioner experiences of the diagnostic pathway. This novel presentation of patient and general practitioner perspectives indicates that systemic interventions have a role in timely and appropriate referrals to specialist care and coordination of investigations. Systemic interventions may alleviate concerns about urgency of diagnostic workup, communication, and coordination of care as patients transition from primary to specialist care.
Is patient size important in dose determination and optimization in cardiology?
NASA Astrophysics Data System (ADS)
Reay, J.; Chapple, C. L.; Kotre, C. J.
2003-12-01
Patient dose determination and optimization have become more topical in recent years with the implementation of the Medical Exposures Directive into national legislation, the Ionising Radiation (Medical Exposure) Regulations. This legislation incorporates a requirement for new equipment to provide a means of displaying a measure of patient exposure and introduces the concept of diagnostic reference levels. It is normally assumed that patient dose is governed largely by patient size; however, in cardiology, where procedures are often very complex, the significance of patient size is less well understood. This study considers over 9000 cardiology procedures, undertaken throughout the north of England, and investigates the relationship between patient size and dose. It uses simple linear regression to calculate both correlation coefficients and significance levels for data sorted by both room and individual clinician for the four most common examinations, left ventrical and/or coronary angiography, single vessel stent insertion and single vessel angioplasty. This paper concludes that the correlation between patient size and dose is weak for the procedures considered. It also illustrates the use of an existing method for removing the effect of patient size from dose survey data. This allows typical doses and, therefore, reference levels to be defined for the purposes of dose optimization.
EOS MLS Level 1B Data Processing Software. Version 3
NASA Technical Reports Server (NTRS)
Perun, Vincent S.; Jarnot, Robert F.; Wagner, Paul A.; Cofield, Richard E., IV; Nguyen, Honghanh T.; Vuu, Christina
2011-01-01
This software is an improvement on Version 2, which was described in EOS MLS Level 1B Data Processing, Version 2.2, NASA Tech Briefs, Vol. 33, No. 5 (May 2009), p. 34. It accepts the EOS MLS Level 0 science/engineering data, and the EOS Aura spacecraft ephemeris/attitude data, and produces calibrated instrument radiances and associated engineering and diagnostic data. This version makes the code more robust, improves calibration, provides more diagnostics outputs, defines the Galactic core more finely, and fixes the equator crossing. The Level 1 processing software manages several different tasks. It qualifies each data quantity using instrument configuration and checksum data, as well as data transmission quality flags. Statistical tests are applied for data quality and reasonableness. The instrument engineering data (e.g., voltages, currents, temperatures, and encoder angles) is calibrated by the software, and the filter channel space reference measurements are interpolated onto the times of each limb measurement with the interpolates being differenced from the measurements. Filter channel calibration target measurements are interpolated onto the times of each limb measurement, and are used to compute radiometric gain. The total signal power is determined and analyzed by each digital autocorrelator spectrometer (DACS) during each data integration. The software converts each DACS data integration from an autocorrelation measurement in the time domain into a spectral measurement in the frequency domain, and estimates separately the spectrally, smoothly varying and spectrally averaged components of the limb port signal arising from antenna emission and scattering effects. Limb radiances are also calibrated.
Diagnostic Peptide Discovery: Prioritization of Pathogen Diagnostic Markers Using Multiple Features
Carmona, Santiago J.; Sartor, Paula A.; Leguizamón, María S.; Campetella, Oscar E.; Agüero, Fernán
2012-01-01
The availability of complete pathogen genomes has renewed interest in the development of diagnostics for infectious diseases. Synthetic peptide microarrays provide a rapid, high-throughput platform for immunological testing of potential B-cell epitopes. However, their current capacity prevent the experimental screening of complete “peptidomes”. Therefore, computational approaches for prediction and/or prioritization of diagnostically relevant peptides are required. In this work we describe a computational method to assess a defined set of molecular properties for each potential diagnostic target in a reference genome. Properties such as sub-cellular localization or expression level were evaluated for the whole protein. At a higher resolution (short peptides), we assessed a set of local properties, such as repetitive motifs, disorder (structured vs natively unstructured regions), trans-membrane spans, genetic polymorphisms (conserved vs. divergent regions), predicted B-cell epitopes, and sequence similarity against human proteins and other potential cross-reacting species (e.g. other pathogens endemic in overlapping geographical locations). A scoring function based on these different features was developed, and used to rank all peptides from a large eukaryotic pathogen proteome. We applied this method to the identification of candidate diagnostic peptides in the protozoan Trypanosoma cruzi, the causative agent of Chagas disease. We measured the performance of the method by analyzing the enrichment of validated antigens in the high-scoring top of the ranking. Based on this measure, our integrative method outperformed alternative prioritizations based on individual properties (such as B-cell epitope predictors alone). Using this method we ranked 10 million 12-mer overlapping peptides derived from the complete T. cruzi proteome. Experimental screening of 190 high-scoring peptides allowed the identification of 37 novel epitopes with diagnostic potential, while none of the low scoring peptides showed significant reactivity. Many of the metrics employed are dependent on standard bioinformatic tools and data, so the method can be easily extended to other pathogen genomes. PMID:23272069
Pankhurst, Louise J; del Ojo Elias, Carlos; Votintseva, Antonina A; Walker, Timothy M; Cole, Kevin; Davies, Jim; Fermont, Jilles M; Gascoyne-Binzi, Deborah M; Kohl, Thomas A; Kong, Clare; Lemaitre, Nadine; Niemann, Stefan; Paul, John; Rogers, Thomas R; Roycroft, Emma; Smith, E Grace; Supply, Philip; Tang, Patrick; Wilcox, Mark H; Wordsworth, Sarah; Wyllie, David; Xu, Li; Crook, Derrick W
2016-01-01
Summary Background Slow and cumbersome laboratory diagnostics for Mycobacterium tuberculosis complex (MTBC) risk delayed treatment and poor patient outcomes. Whole-genome sequencing (WGS) could potentially provide a rapid and comprehensive diagnostic solution. In this prospective study, we compare real-time WGS with routine MTBC diagnostic workflows. Methods We compared sequencing mycobacteria from all newly positive liquid cultures with routine laboratory diagnostic workflows across eight laboratories in Europe and North America for diagnostic accuracy, processing times, and cost between Sept 6, 2013, and April 14, 2014. We sequenced specimens once using local Illumina MiSeq platforms and processed data centrally using a semi-automated bioinformatics pipeline. We identified species or complex using gene presence or absence, predicted drug susceptibilities from resistance-conferring mutations identified from reference-mapped MTBC genomes, and calculated genetic distance to previously sequenced UK MTBC isolates to detect outbreaks. WGS data processing and analysis was done by staff masked to routine reference laboratory and clinical results. We also did a microcosting analysis to assess the financial viability of WGS-based diagnostics. Findings Compared with routine results, WGS predicted species with 93% (95% CI 90–96; 322 of 345 specimens; 356 mycobacteria specimens submitted) accuracy and drug susceptibility also with 93% (91–95; 628 of 672 specimens; 168 MTBC specimens identified) accuracy, with one sequencing attempt. WGS linked 15 (16% [95% CI 10–26]) of 91 UK patients to an outbreak. WGS diagnosed a case of multidrug-resistant tuberculosis before routine diagnosis was completed and discovered a new multidrug-resistant tuberculosis cluster. Full WGS diagnostics could be generated in a median of 9 days (IQR 6–10), a median of 21 days (IQR 14–32) faster than final reference laboratory reports were produced (median of 31 days [IQR 21–44]), at a cost of £481 per culture-positive specimen, whereas routine diagnosis costs £518, equating to a WGS-based diagnosis cost that is 7% cheaper annually than are present diagnostic workflows. Interpretation We have shown that WGS has a scalable, rapid turnaround, and is a financially feasible method for full MTBC diagnostics. Continued improvements to mycobacterial processing, bioinformatics, and analysis will improve the accuracy, speed, and scope of WGS-based diagnosis. Funding National Institute for Health Research, Department of Health, Wellcome Trust, British Colombia Centre for Disease Control Foundation for Population and Public Health, Department of Clinical Microbiology, Trinity College Dublin. PMID:26669893
Robinson, James C; Whaley, Christopher; Brown, Timothy T
2016-09-01
Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with access to price information, reference pricing was associated with patient choice of lower-cost laboratories and reductions in prices and payments by both employer and employees.
Variability of Late-Night Salivary Cortisol in Cushing Disease: A Prospective Study.
Sandouk, Zahrae; Johnston, Philip; Bunch, Dustin; Wang, Sihe; Bena, James; Hamrahian, Amir; Kennedy, Laurence
2018-03-01
The frequency of variable hormonogenesis in patients with Cushing disease (CD) but without cyclical symptoms is unclear. To assess the frequency of variable hormonogenesis in patients presenting with CD. Over a 6-month period, patients with confirmed or suspected CD provided late-night salivary samples for up to 42 consecutive nights. Of 19 patients confirmed to have CD, 16 provided at least 7 consecutive salivary samples, and 13 provided at least 21; these 16 patients are the subjects of this report. Twelve patients had at least three peak and two trough levels of late-night salivary cortisol (LNSC) but in only two patients were strict criteria for cyclical hormonogenesis fulfilled; variation was assessed as random in the others. Eight patients had de novo CD, and eight had recurrent/persistent disease. All patients with recurrent/persistent CD had two or more normal results, and in four of these patients, >50% of LNSC were normal. In six patients with de novo disease with at least one normal LNSC level, the maximum levels ranged from 1.55 to 15.5 times the upper limit of normal. Extreme fluctuations of cortisol production, measured by sequential LNSC, are common in CD. In newly diagnosed disease, this may only occasionally impair diagnostic ability, whereas in most patients with recurrent/persistent disease after pituitary surgery, LNSC is frequently within the reference range, with potential to cause diagnostic problems.
[When should a patient with abdominal pain be referred to the emergency ward?].
de Saussure, Wassila Oulhaci; Andereggen, Elisabeth; Sarasin, François
2010-08-25
When should a patient with abdominal pain be referred to the emergency ward? The following goals must be achieved upon managing patients with acute abdominal pain: 1) identify vital emergency situations; 2) detect surgical conditions that require emergency referral without further diagnostic procedures; 3) in "non surgical acute abdomen patients" perform appropriate diagnostic procedures, or in selected cases delay tests and reevaluate the patient after an observation period, after which a referral decision is made. Clues from the history and physical examination are critical to perform this evaluation. A good knowledge of the most frequent acute abdominal conditions, and identifying potential severity criteria allow an appropriate management and decision about emergency referral.
Barber, T J; Bansi, L; Pozniak, A; Asboe, D; Nelson, M; Moyle, G; Davies, N; Margetts, A; Ratcliffe, D; Catalan, J; Boffito, M; Gazzard, B
2017-06-01
This study aimed to determine the prevalence of HIV neurocognitive impairment in HIV-infected men who have sex with men aged 18-50 years, using a simple battery of screening tests in routine clinical appointments. Those with suspected abnormalities were referred on for further assessment. The cohort was also followed up over time to look at evolving changes. HIV-infected participants were recruited at three clinical sites in London during from routine clinical visits. They could be clinician or self-referred and did not need to be symptomatic. They completed questionnaires on anxiety, depression, and memory. They were then screened using the Brief Neurocognitive Screen (BNCS) and International HIV Dementia Scale (IHDS). Two hundred and five HIV-infected subjects were recruited. Of these, 59 patients were excluded as having a mood disorder and two patients were excluded due to insufficient data, leaving 144 patients for analysis. One hundred and twenty-four (86.1%) had a normal composite z score (within 1 SD of mean) calculated for their scores on the three component tests of the BNCS. Twenty (13.9%) had an abnormal z score, of which seven (35%) were symptomatic and 13 (65%) asymptomatic. Current employment and previous educational level were significantly associated with BNCS scores. Of those referred onwards for diagnostic testing, only one participant was found to have impairment likely related to HIV infection. We were able to easily screen for mood disorders and cognitive impairment in routine clinical practice. We identified a high level of depression and anxiety in our cohort. Using simple screening tests in clinic and an onward referral process for further testing, we were not able to identify neurocognitive impairment in this cohort at levels consistent with published data.
Maas, E T; Juch, J N S; Ostelo, R W J G; Groeneweg, J G; Kallewaard, J W; Koes, B W; Verhagen, A P; Huygen, F J P M; van Tulder, M W
2017-03-01
Patient history and physical examination are frequently used procedures to diagnose chronic low back pain (CLBP) originating from the facet joints, although the diagnostic accuracy is controversial. The aim of this systematic review is to determine the diagnostic accuracy of patient history and/or physical examination to identify CLBP originating from the facet joints using diagnostic blocks as reference standard. We searched MEDLINE, EMBASE, CINAHL, Web of Science and the Cochrane Collaboration database from inception until June 2016. Two review authors independently selected studies for inclusion, extracted data and assessed the risk of bias. We calculated sensitivity and specificity values, with 95% confidence intervals (95% CI). Twelve studies were included, in which 129 combinations of index tests and reference standards were presented. Most of these index tests have only been evaluated in single studies with a high risk of bias. Four studies evaluated the diagnostic accuracy of the Revel's criteria combination. Because of the clinical heterogeneity, results were not pooled. The published sensitivities ranged from 0.11 (95% CI 0.02-0.29) to 1.00 (95% CI 0.75-1.00), and the specificities ranged from 0.66 (95% CI 0.46-0.82) to 0.91 (95% CI 0.83-0.96). Due to clinical heterogeneity, the evidence for the diagnostic accuracy of patient history and/or physical examination to identify facet joint pain is inconclusive. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. © 2016 European Pain Federation - EFIC®.
Guo, Ying; Du, Xiang-Yang; Huang, Hua-Lan; Wang, Wei-Qing; Nie, Xin; Li, Gui-Xing
2017-11-01
To establish the reference value of high sensitive cardiac troponin T (hs-cTnT) and the efficiency of reference value in the diagnosis of chest pain. Volunteers from eight independent communities in Chengdu,Sichuan were selected with detailed records of physical examination,electrocardiogram,ultrasound examination. The level of hs-cTnT for healthy volunteers was tested to determine ninety-ninth percentile references according to sex and ages. 2 249 patients with chest pain in the emergency department of Western China Hospital from July 2009 to July 2014 were enrolled to measure the efficiency of reference value for diagnosing acute myocardial infarction (AMI). There were 1 305 volunteers included finally. Among them,the mean hs-cTnT level of male was 4.3 (3.2-5.9) ng/L,which was significantly higher than that of female 3.0 (3.0-3.1) ng/L ( P <0.01) . The correlation coefficient between age and hs-cTnT level was 0.43 (male) and 0.29 (female),and the P -value was less than 0.01. The 99th percentile values of male were 10.8 ng/L,15.4 ng/L and 19.7 ng/L for <45 yr.,45-<60 yr. and ≥60 yr.,respectively. Those values of female were 4.6 ng/L,8.9 ng/L,18.8 ng/L,respectively. There was no difference in sensitivity and specificity between the value we figured out and manufactures provided (14.0 ng/L) for those<60 yr.. For the patients ≥60 yr.,the sensitivity and negative predictive value did not show diversity ( P >0.05) but the specificity and positive predictive value showed significant difference (male: 0.67 vs. 0.56 and 0.83 vs. 0.79, P <0.05;female:0.75 vs. 0.68 and 0.74 vs. 0.69, P <0.05). We recommends that the ninety-ninth percentile reference value of patients<60 yr. should be 14.0 ng/L,while 20.0 ng/L for those patients≥60 yr.
Teirilä, Laura; Karvala, Kirsi; Ahonen, Niina; Riska, Henrik; Pietinalho, Anne; Tuominen, Päivi; Piirilä, Päivi
2014-01-01
Background Hyperresponsiveness to inhaled non-infectious microbial particles (NIMPs) has been associated with illnesses in the airways. Hypersensitivity pneumonitis (HP) is considered to be the prototype for these NIMPs-related diseases; however, there is no consensus on the definitions or diagnostic criteria for HP and the spectrum of related illnesses. Methods and Findings In order to identify the possible diagnostic markers for illnesses associated with NIMPs in alveolar lining fluid, we performed a proteomic analysis using a two-dimensional difference gel electrophoresis on bronchoalveolar lavage (BAL) fluid from patients with exposure to NIMPs in the context of damp building-related illness (DBRI) or conditions on the borderline to acute HP, designated here as agricultural type of microbial exposure (AME). Samples from patients with HP and sarcoidosis (SARC) were included for reference. Results were compared to results of healthy subjects (CTR). Western blot was used for validation of potential marker proteins from BAL fluid and plasma. Protein expression patterns suggest a close similarity between AME and HP, while DBRI was similar to CTR. However, in DBRI the levels of the inflammation associated molecules galectin-3 and alpha-1-antitrypsin were increased. A novel finding emerging from this study was the increases of semenogelin levels in BAL fluid from patients with AME, HP and SARC. Histone 4 levels were increased in AME, HP and SARC. Elevated plasma levels of histone 2B were detected in HP and SARC, suggesting it to be a potential blood indicator for inflammatory diseases of the lungs. Conclusions In this study, the proteomic changes in bronchoalveolar lavage of DBRI patients were distinct from other NIMP exposure associated lung diseases, while changes in AME overlapped those observed for HP patient samples. Some of the proteins identified in this study, semenogelin and histone 4, could function as diagnostic markers for differential diagnosis between DBRI and HP-like conditions. PMID:25033447
Thway, Khin; Mubako, Taka
2014-01-01
Introduction. Soft tissue tumour pathology is a highly specialised area of surgical pathology, but soft tissue neoplasms can occur at virtually all sites and are therefore encountered by a wide population of surgical pathologists. Potential sarcomas require referral to specialist centres for review by pathologists who see a large number of soft tissue lesions and where appropriate ancillary investigations can be performed. We have previously assessed the types of diagnostic discrepancies between referring and final diagnosis for soft tissue lesions referred to our tertiary centre. We now reaudit this 6 years later, assessing changes in discrepancy patterns, particularly in relation to the now widespread use of ancillary molecular diagnostic techniques which were not prevalent in our original study. Materials and Methods. We compared the sarcoma unit's histopathology reports with referring reports on 348 specimens from 286 patients with suspected or proven soft tissue tumours in a one-year period. Results. Diagnostic agreement was seen in 250 cases (71.8%), with 57 (16.4%) major and 41 (11.8%) minor discrepancies. There were 23 cases of benign/malignant discrepancies (23.5% of all discrepancies). 50 ancillary molecular tests were performed, 33 for aiding diagnosis and 17 mutational analyses for gastrointestinal stromal tumour to guide therapy. Findings from ancillary techniques contributed to 3 major and 4 minor discrepancies. While the results were broadly similar to those of the previous study, there was an increase in frequency of major discrepancies. Conclusion. Six years following our previous study and notably now in an era of widespread ancillary molecular diagnosis, the overall discrepancy rate between referral and tertiary centre diagnosis remains similar, but there is an increase in frequency of major discrepancies likely to alter patient management. A possible reason for the increase in major discrepancies is the increasing lack of exposure to soft tissue cases in nonspecialist centres in a time of subspecialisation. The findings support the national guidelines in which all suspected soft tissue tumour pathology specimens should be referred to a specialist sarcoma unit. PMID:25165418
Thway, Khin; Wang, Jayson; Mubako, Taka; Fisher, Cyril
2014-01-01
Introduction. Soft tissue tumour pathology is a highly specialised area of surgical pathology, but soft tissue neoplasms can occur at virtually all sites and are therefore encountered by a wide population of surgical pathologists. Potential sarcomas require referral to specialist centres for review by pathologists who see a large number of soft tissue lesions and where appropriate ancillary investigations can be performed. We have previously assessed the types of diagnostic discrepancies between referring and final diagnosis for soft tissue lesions referred to our tertiary centre. We now reaudit this 6 years later, assessing changes in discrepancy patterns, particularly in relation to the now widespread use of ancillary molecular diagnostic techniques which were not prevalent in our original study. Materials and Methods. We compared the sarcoma unit's histopathology reports with referring reports on 348 specimens from 286 patients with suspected or proven soft tissue tumours in a one-year period. Results. Diagnostic agreement was seen in 250 cases (71.8%), with 57 (16.4%) major and 41 (11.8%) minor discrepancies. There were 23 cases of benign/malignant discrepancies (23.5% of all discrepancies). 50 ancillary molecular tests were performed, 33 for aiding diagnosis and 17 mutational analyses for gastrointestinal stromal tumour to guide therapy. Findings from ancillary techniques contributed to 3 major and 4 minor discrepancies. While the results were broadly similar to those of the previous study, there was an increase in frequency of major discrepancies. Conclusion. Six years following our previous study and notably now in an era of widespread ancillary molecular diagnosis, the overall discrepancy rate between referral and tertiary centre diagnosis remains similar, but there is an increase in frequency of major discrepancies likely to alter patient management. A possible reason for the increase in major discrepancies is the increasing lack of exposure to soft tissue cases in nonspecialist centres in a time of subspecialisation. The findings support the national guidelines in which all suspected soft tissue tumour pathology specimens should be referred to a specialist sarcoma unit.
Method and apparatus for holographic wavefront diagnostics
Toeppen, J.S.
1995-04-25
A wavefront diagnostic apparatus has an optic and a measuring system. The optic forms a holographic image in response to a beam of light striking a hologram formed on a surface of the optic. The measuring system detects the position of the array of holographic images and compares the positions of the array of holographic images to a reference holographic image. 3 figs.
Method and apparatus for holographic wavefront diagnostics
Toeppen, John S.
1995-01-01
A wavefront diagnostic apparatus has an optic and a measuring system. The optic forms a holographic image in response to a beam of light striking a hologram formed on a surface of the optic. The measuring system detects the position of the array of holographic images and compares the positions of the array of holographic images to a reference holographic image.
Approach to building knowledge bases in information-measuring systems diagnostics of acute leukemias
NASA Astrophysics Data System (ADS)
Nikitaev, V. G.; Pronichev, A. N.; Polyakov, E. V.; Dmitrieva, V. V.
2018-01-01
The paper describes an approach for the formation of the reference base of peripheral blood cells and bone marrow in information-measuring systems of acute leukemia diagnostics. The proposed approach has allowed to create a system, that is enable peer evaluation of blood cells needed for the training of recognition systems when carrying out microscopic studies.
Sivasankar, Amarapathy; Jeswanth, Sathyanesan; Johnson, Maria Antony; Ravichandran, Palaniappan; Rajendran, Shanmugasundaram; Kannan, Devy Gounder; Surendran, Rajagopal
2006-01-01
We report three cases of acutely bleeding adrenal pseudocysts presenting as hemorrhagic shock. Pregnancy was associated in two cases. The diagnostic dilemmas are discussed with special reference to their unusual presentations, diagnosis, and treatment. We believe that our cases, complicated by intracystic hemorrhage, may be related to pregnancy. PMID:17619705
Diagnostic multiplex PCR for toxin genotyping of Clostridium perfringens isolates.
Baums, Christoph G; Schotte, Ulrich; Amtsberg, Gunter; Goethe, Ralph
2004-05-20
In this study we provide a protocol for genotyping Clostridium perfringens with a new multiplex PCR. This PCR enables reliable and specific detection of the toxin genes cpa, cpb, etx, iap, cpe and cpb2 from heat lysed bacterial suspensions. The efficiency of the protocol was demonstrated by typing C. perfringens reference strains and isolates from veterinary bacteriological routine diagnostic specimens.
40 CFR 86.1 - Reference materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
....007-17, 86.1806-01, 86.1806-04, 86.1806-05. (xxxii) SAE J1979, Revised May 2007, (R) E/E Diagnostic... J2012, Revised April 2002, (R) Diagnostic Trouble Code Definitions Equivalent to ISO/DIS 15031-6: April... Vehicle Programming, IBR approved for §§ 86.096-38, 86.004-38, 86.007-38, 86.010-38, 86.1808-01, 86.1808...
Computer-assisted diagnostic decision support: history, challenges, and possible paths forward.
Miller, Randolph A
2009-09-01
This paper presents a brief history of computer-assisted diagnosis, including challenges and future directions. Some ideas presented in this article on computer-assisted diagnostic decision support systems (CDDSS) derive from prior work by the author and his colleagues (see list in Acknowledgments) on the INTERNIST-1 and QMR projects. References indicate the original sources of many of these ideas.
NASA Technical Reports Server (NTRS)
Zimetbaum, P. J.; Kim, K. Y.; Josephson, M. E.; Goldberger, A. L.; Cohen, D. J.
1998-01-01
BACKGROUND: Continuous-loop event recorders are widely used for the evaluation of palpitations, but the optimal duration of monitoring is unknown. OBJECTIVE: To determine the yield, timing, and incremental cost-effectiveness of each week of event monitoring for palpitations. DESIGN: Prospective cohort study. PATIENTS: 105 consecutive outpatients referred for the placement of a continuous-loop event recorder for the evaluation of palpitations. MEASUREMENTS: Diagnostic yield, incremental cost, and cost-effectiveness for each week of monitoring. RESULTS: The diagnostic yield of continuous-loop event recorders was 1.04 diagnoses per patient in week 1, 0.15 diagnoses per patient in week 2, and 0.01 diagnoses per patient in week 3 and beyond. Over time, the cost-effectiveness ratio increased from $98 per new diagnosis in week 1 to $576 per new diagnosis in week 2 and $5832 per new diagnosis in week 3. CONCLUSIONS: In patients referred for evaluation of palpitations, the diagnostic yield of continuous-loop event recording decreases rapidly after 2 weeks of monitoring. A 2-week monitoring period is reasonably cost-effective for most patients and should be the standard period for continuous-loop event recording for the evaluation of palpitations.
Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar
2009-11-13
Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004-2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.
Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar
2009-01-01
Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases. PMID:19915664
ERIC Educational Resources Information Center
Wilson, Lonny; And Others
1986-01-01
Demographic data, IQ, achievement, perceptual-motor, behavior ratings, and diagnostic classification (learning, mental, emotional disability or no handicap) were analyzed for all children (N=2002) referred for complete psychological evaluation during one school year in Iowa. Learning disabled children showed a distinct pattern different from…
Untreated ADHD in Adults: Are There Sex Differences in Symptoms, Comorbidity, and Impairment?
ERIC Educational Resources Information Center
Rasmussen, Kirsten; Levander, Sten
2009-01-01
Objective: To analyze sex differences among adult, never-treated patients referred for central stimulant treatment of ADHD. Method: Data for 600 consecutive patients from northern Norway referred for evaluation by an expert team during 7 years were analyzed. General background information, diagnostic and social history, and symptom profiles were…
Design of a diagnostic encyclopaedia using AIDA.
van Ginneken, A M; Smeulders, A W; Jansen, W
1987-01-01
Diagnostic Encyclopaedia Workstation (DEW) is the name of a digital encyclopaedia constructed to contain reference knowledge with respect to the pathology of the ovary. Comparing DEW with the common sources of reference knowledge (i.e. books) leads to the following advantages of DEW: it contains more verbal knowledge, pictures and case histories, and it offers information adjusted to the needs of the user. Based on an analysis of the structure of this reference knowledge we have chosen AIDA to develop a relational database and we use a video-disc player to contain the pictorial part of the database. The system consists of a database input version and a read-only run version. The design of the database input version is discussed. Reference knowledge for ovary pathology requires 1-3 Mbytes of memory. At present 15% of this amount is available. The design of the run version is based on an analysis of which information must necessarily be specified to the system by the user to access a desired item of information. Finally, the use of AIDA in constructing DEW is evaluated.
Rösler, M; Retz, W; Retz-Junginger, P; Stieglitz, R D; Kessler, H; Reimherr, F; Wender, P H
2008-03-01
We report on a study comparing different systems for the diagnosis of attention deficit hyperactivity disorder (ADHD) in adulthood. Recruited for evaluation were 168 patients referred to our ADHD outpatient unit. We used the Diagnostic and Statistical Manual of Mental Disorders 4th edn. (DSM-IV), International Classification of Diseases 10th edn. (ICD-10), and Utah criteria for diagnostic assessment and the Wender Utah rating scale, ADHD Self Report (ADHD-SR), and Wender Reimherr Adult Attention Deficit Disorder Rating Scale as psychopathological assessment tools. We present basic psychometric data of the Wender-Reimherr Interview (WRI). Internal consistency was determined as 0.82 (alpha). The inter-rater reliability was 1.0 (kappa coefficient) regarding ADHD diagnoses, and the ICC was 0.98 referring to the WRI total scores. The convergent validity with the ADHD-SR was 0.65 (Spearman coefficient). In 126 of 168 patients an ADHD diagnosis was made according to at least one of the three systems. The DSM-IV diagnostic set led to 119 ADHD diagnoses. As compared with the two other systems, this is about the minimum level for an ADHD diagnosis. All of the 87 ADHD diagnoses according to ICD-10 were covered by DSM-IV. The ICD-10 had no independent psychopathological items and therefore offered no additional points for the diagnostic procedure than the DSM-IV. The situation regarding Utah criteria is different. These criteria contain seven psychopathological domains: inattention, hyperactivity, disorganisation, impulsivity, affective lability, overreactivity, and hot temper. They can be assessed by use of the WRI. Ninety-three of 168 patients were diagnosed as having ADHD according to the Utah concept, which is much lower than with the DSM-IV. The particular definition of the disorder by the Utah criteria resulted in seven patients having only a Utah diagnosis but no DSM-IV diagnosis. Thus we are in a position to say that the Utah criteria have a relatively high level for making an ADHD diagnosis but in certain cases move beyond the DSM-IV. Of the patients 56% had ADHD diagnoses according to all three classification instruments. Examining the factor structure of the ADHD psychopathology represented by seven WRI and three ADHD-SR subscales, we found a two-factor solution explaining for 63% of the variance. Factor 1 was designated by impulsivity, affective lability, hyperactivity, and hot temper; factor 2 consisted of inattention, disorganisation, and overreactivity.
Savage, Nathan J; Fritz, Julie M; Thackeray, Anne
2014-07-01
Cross-sectional diagnostic accuracy study. To investigate the relationship between history and physical examination findings and the outcome of electrodiagnostic testing in patients with sciatica referred to physical therapy. Electrodiagnostic testing is routinely used to evaluate patients with sciatica. Recent evidence suggests that the presence of radiculopathy identified with electrodiagnostic testing may predict better functional outcomes in these patients. While some patient history and physical examination findings have been shown to predict the presence of disc herniation or neurological insult, little is known about their relationship to the results of electrodiagnostic testing. Electrodiagnostic testing was performed on 38 patients with sciatica who participated in a randomized trial that compared different physical therapy interventions. The diagnostic gold standard was the presence or absence of radiculopathy, based on the results of the needle electromyographic examination. Diagnostic sensitivity and specificity values were calculated, along with corresponding likelihood ratios, for select patient history and physical examination variables. No significant relationship was found between select patient history and physical examination findings, analyzed individually or in combination, and the outcome of electrodiagnostic testing. Diagnostic sensitivity values ranged from 0.03 (95% confidence interval [CI]: 0.00, 0.24) to a high of 0.95 (95% CI: 0.72, 0.99), and specificity values ranged from 0.10 (95% CI: 0.02, 0.34) to a high of 0.95 (95% CI: 0.72, 0.99). Positive likelihood ratios ranged from 0.15 (95% CI: 0.01, 2.87) to a high of 2.33 (95% CI: 0.71, 7.70), and negative likelihood ratios ranged from 2.00 (95% CI: 0.35, 11.48) to a low of 0.50 (95% CI: 0.03, 8.10). In this investigation, the relationship between patient history and physical examination findings and the outcome of electrodiagnostic testing among patients with sciatica was not found to be statistically significant or clinically meaningful. However, given the small sample size and corresponding large CIs, these results should be considered with caution, recognizing that some of the history and physical examination variables may prove useful in future research. These findings suggest that electrodiagnostic testing is essential to identify the subgroup of patients with sciatica who have measurable nerve injury consistent with radiculopathy, which may be an important prognostic factor for recovery. Level of Evidence Diagnosis, level 3b-. J Orthop Sports Phys Ther 2014;44(7):508-517. Epub 22 May 2014. doi:10.2519/jospt.2014.5002.
Genetics Home Reference: Hennekam syndrome
... Primary Intestinal Lymphangiectasia Information Johns Hopkins Medicine: Lymphedema Management (PDF) VascularWeb: Lymphedema General Information from MedlinePlus (5 links) Diagnostic Tests Drug Therapy ...
Evaluation and treatment of sex addiction.
Rosenberg, Kenneth Paul; Carnes, Patrick; O'Connor, Suzanne
2014-01-01
There have been several diagnostic labels for persistent, excessive sexual behaviors, often referred in the popular media as sex addiction. Two related diagnoses, Internet addictive disorder and hypersexual disorder, were considered for, but not included in the 5th edition of the Diagnostic and Statistical Manual of Mental Disorders. However, most clinicians, even those trained in sexual disorders or addiction medicine, have little to no training in treating sexual compulsivity and cybersex addiction. The authors present the historical context, proposed diagnostic criteria, evaluation protocols, comorbid disorders, speculations about the neuroscience, and treatment recommendations.
Drug-device trials for infectious diseases: CDRH perspective.
Meier, Kristen L; Gitterman, Steven
2011-05-01
Assessing the performance of new diagnostic tests for infectious diseases has traditionally focused on comparing the new assay against a reference standard such as culture. In this paper, we suggest that clinical trial designs with both a diagnostic and therapeutic component may be necessary to evaluate the safety and effectiveness of nonmicrobiologically based assays, with a specific emphasis on the test/marker-stratified design. General design challenges for trials of infectious diseases that simultaneously study both diagnostic and therapeutic components (eg, both devices and drugs) are also discussed.
Dandachi-FitzGerald, Brechje; van Twillert, Björn; van de Sande, Peter; van Os, Yindee; Ponds, Rudolf W H M
2016-05-30
We investigated the frequency of symptom validity test (SVT) failure and its clinical correlates in a large, heterogeneous sample of hospital outpatients referred for psychological assessment for clinical purposes. We studied patients (N=469), who were regularly referred for assessment to the psychology departments of five hospitals. Background characteristics, including information about incentives, were obtained with a checklist completed by the clinician. As a measure of over-reporting, the Structured Inventory of Malingered Symptomatology (SIMS) was administered to all patients. The Amsterdam Short-Term Memory test (ASTM), a cognitive underperformance measure, was only administered to patients who were referred for a neuropsychological assessment. Symptom over-reporting occurred in a minority of patients, ranging from 12% to 19% in the main diagnostic patient groups. Patients with morbid obesity had a low rate of over-reporting (1%). The SIMS was positively associated with levels of self-reported psychological symptoms. Cognitive underperformance occurred in 29.3% of the neuropsychological assessments. The ASTM was negatively associated with memory test performance. We found no association between SVT failure and financial incentives. Our results support the recommendation to routinely evaluate symptom validity in clinical assessments of hospital patients. The dynamics behind invalid symptom reporting need to be further elucidated. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Porphyrinuria in childhood autistic disorder is not associated with urinary creatinine deficiency.
Nataf, Robert; Skorupka, Corinne; Lam, Alain; Springbett, Anthea; Lathe, Richard
2008-08-01
Urinary metabolite measurements are often normalized to levels of the ubiquitous metabolite creatinine (CRT) to take account of variations in fluid export. Following CRT normalization, excesses of porphyrins and isoprostanes have been reported in the urines of children with neurodevelopmental disorders. It was suggested (Whiteley et al., 2006, Pediatr. Int. 2006; 48: 292-297) that urinary CRT levels may be depressed in children with autism spectrum disorders. This prompted re-evaluation of CRT levels in such children. First matinal urinary CRT levels were compared between subjects in different diagnostic categories including autistic disorder, pervasive developmental disorder not otherwise specified (PDD-NOS) and hyperactivity, before and after correction for age and gender. A larger reference group, consisting of subjects with unrelated disorders and Asperger disorder, with no reported porphyrin excess, was also compared to the group with autistic disorder, both for CRT and for porphyrin (coproporphyrin, COPRO) excess. No significant difference in CRT was observed between any of the categories analyzed, also when corrected for age and gender. In contrast, urinary COPRO levels were significantly higher in autistic disorder versus reference groups, either when expressed as absolute values (independent of CRT levels) or when normalized to CRT. These data do not support a systematic reduction in urinary CRT levels in subjects with autism spectrum disorders including autistic disorder and PDD-NOS. Urinary COPRO excess in autistic disorder was not associated with or consequent upon urinary CRT deficiency. Differences between affected and control subjects in age and sampling time, as reported by Whiteley et al., may underlie the apparent CRT reduction.
Tsikata, Edem; Lee, Ramon; Shieh, Eric; Simavli, Huseyin; Que, Christian J.; Guo, Rong; Khoueir, Ziad; de Boer, Johannes; Chen, Teresa C.
2016-01-01
Purpose To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. Methods Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB) neuroretinal rim parameter. Traditional 150-μm reference surface–based rim parameters (volume, area, and thickness) were also calculated. The diagnostic capabilities of these five parameters were compared with RNFL thickness using the area under the receiver operating characteristic (AUROC) curves. Results The MDB thickness had significantly higher diagnostic capability than the RNFL thickness in the nasal (0.913 vs. 0.818, P = 0.004) and temporal (0.922 vs. 0.858, P = 0.026) quadrants and the inferonasal (0.950 vs. 0.897, P = 0.011) and superonasal (0.933 vs. 0.868, P = 0.012) sectors. The MDB area and the three neuroretinal rim parameters based on the 150-μm reference surface had diagnostic capabilities similar to RNFL thickness. Conclusions The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility. It had higher diagnostic capability than the RNFL thickness in the nasal and temporal quadrants and the inferonasal and superonasal sectors. PMID:27768203
Vasson, Aurélie; Leroux, Céline; Orhant, Lucie; Boimard, Mathieu; Toussaint, Aurélie; Leroy, Chrystel; Commere, Virginie; Ghiotti, Tiffany; Deburgrave, Nathalie; Saillour, Yoann; Atlan, Isabelle; Fouveaut, Corinne; Beldjord, Cherif; Valleix, Sophie; Leturcq, France; Dodé, Catherine; Bienvenu, Thierry; Chelly, Jamel; Cossée, Mireille
2013-01-01
The frequency of disease-related large rearrangements (referred to as copy-number mutations, CNMs) varies among genes, and search for these mutations has an important place in diagnostic strategies. In recent years, CGH method using custom-designed high-density oligonucleotide-based arrays allowed the development of a powerful tool for detection of alterations at the level of exons and made it possible to provide flexibility through the possibility of modeling chips. The aim of our study was to test custom-designed oligonucleotide CGH array in a diagnostic laboratory setting that analyses several genes involved in various genetic diseases, and to compare it with conventional strategies. To this end, we designed a 12-plex CGH array (135k; 135 000 probes/subarray) (Roche Nimblegen) with exonic and intronic oligonucleotide probes covering 26 genes routinely analyzed in the laboratory. We tested control samples with known CNMs and patients for whom genetic causes underlying their disorders were unknown. The contribution of this technique is undeniable. Indeed, it appeared reproducible, reliable and sensitive enough to detect heterozygous single-exon deletions or duplications, complex rearrangements and somatic mosaicism. In addition, it improves reliability of CNM detection and allows determination of boundaries precisely enough to direct targeted sequencing of breakpoints. All of these points, associated with the possibility of a simultaneous analysis of several genes and scalability ‘homemade' make it a valuable tool as a new diagnostic approach of CNMs. PMID:23340513
Diagnostic Utility of Total IgE in Foods, Inhalant, and Multiple Allergies in Saudi Arabia.
Al-Mughales, Jamil A
2016-01-01
Objective. To assess the diagnostic significance of total IgE in foods, inhalant, and multiple allergies. Methods. Retrospective review of the laboratory records of patients who presented with clinical suspicion of food or inhalant allergy between January 2013 and December 2014. Total IgE level was defined as positive for a value >195 kU/L; and diagnosis was confirmed by the detection of specific IgE (golden standard) for at least one food or inhalant allergen and at least two allergens in multiple allergies. Results. A total of 1893 (male ratio = 0.68, mean age = 39.0 ± 19.2 years) patients were included. Total IgE had comparable sensitivity (55.8% versus 59.6%) and specificity (83.9% versus 84.4%) in food versus inhalant allergy, respectively, but a superior PPV in inhalant allergy (79.1% versus 54.4%). ROC curve analysis showed a better diagnostic value in inhalant allergies (AUC = 0.817 (95% CI = 0.796-0.837) versus 0.770 (95% CI = 0.707-0.833)). In multiple allergies, total IgE had a relatively good sensitivity (78.6%), while negative IgE testing (<195 kU/L) predicted the absence of multiple allergies with 91.5% certitude. Conclusion. Total IgE assay is not efficient as a diagnostic test for foods, inhalant, or multiple allergies. The best strategy should refer to specific IgE testing guided by a comprehensive atopic history.
Diagnostic Utility of Total IgE in Foods, Inhalant, and Multiple Allergies in Saudi Arabia
Al-Mughales, Jamil A.
2016-01-01
Objective. To assess the diagnostic significance of total IgE in foods, inhalant, and multiple allergies. Methods. Retrospective review of the laboratory records of patients who presented with clinical suspicion of food or inhalant allergy between January 2013 and December 2014. Total IgE level was defined as positive for a value >195 kU/L; and diagnosis was confirmed by the detection of specific IgE (golden standard) for at least one food or inhalant allergen and at least two allergens in multiple allergies. Results. A total of 1893 (male ratio = 0.68, mean age = 39.0 ± 19.2 years) patients were included. Total IgE had comparable sensitivity (55.8% versus 59.6%) and specificity (83.9% versus 84.4%) in food versus inhalant allergy, respectively, but a superior PPV in inhalant allergy (79.1% versus 54.4%). ROC curve analysis showed a better diagnostic value in inhalant allergies (AUC = 0.817 (95% CI = 0.796–0.837) versus 0.770 (95% CI = 0.707–0.833)). In multiple allergies, total IgE had a relatively good sensitivity (78.6%), while negative IgE testing (<195 kU/L) predicted the absence of multiple allergies with 91.5% certitude. Conclusion. Total IgE assay is not efficient as a diagnostic test for foods, inhalant, or multiple allergies. The best strategy should refer to specific IgE testing guided by a comprehensive atopic history. PMID:27314052
Computer-aided dermoscopy for diagnosis of melanoma
Barzegari, Masoomeh; Ghaninezhad, Haiedeh; Mansoori, Parisa; Taheri, Arash; Naraghi, Zahra S; Asgari, Masood
2005-01-01
Background Computer-aided dermoscopy using artificial neural networks has been reported to be an accurate tool for the evaluation of pigmented skin lesions. We set out to determine the sensitivity and specificity of a computer-aided dermoscopy system for diagnosis of melanoma in Iranian patients. Methods We studied 122 pigmented skin lesions which were referred for diagnostic evaluation or cosmetic reasons. Each lesion was examined by two clinicians with naked eyes and all of their clinical diagnostic considerations were recorded. The lesions were analyzed using a microDERM® dermoscopy unit. The output value of the software for each lesion was a score between 0 and 10. All of the lesions were excised and examined histologically. Results Histopathological examination revealed melanoma in six lesions. Considering only the most likely clinical diagnosis, sensitivity and specificity of clinical examination for diagnosis of melanoma were 83% and 96%, respectively. Considering all clinical diagnostic considerations, the sensitivity and specificity were 100% and 89%. Choosing a cut-off point of 7.88 for dermoscopy score, the sensitivity and specificity of the score for diagnosis of melanoma were 83% and 96%, respectively. Setting the cut-off point at 7.34, the sensitivity and specificity were 100% and 90%. Conclusion The diagnostic accuracy of the dermoscopy system was at the level of clinical examination by dermatologists with naked eyes. This system may represent a useful tool for screening of melanoma, particularly at centers not experienced in the field of pigmented skin lesions. PMID:16000171
Christian, P D; Gibb, N; Kasprzak, A B; Richards, A
2001-07-01
A diagnostic method is described for the identification and differentiation of nucleopolyhedrovirus (NPV) pathogens of Helicoverpa species (Lepidoptera: Noctuidae) isolated from the environment. The method is based on the polymerase chain reaction (PCR) used in conjunction with restriction fragment length polymorphism (RFLP) analysis and comprises three parts. The first part describes procedures for obtaining PCR quality viral DNA from individual diseased H. armigera cadavers recovered during bioassay analyses of soil and other types of environmental sample. These procedures were modified from standard techniques used for the routine purification and dissolution of NPV polyhedra and provided an overall PCR success rate of 95% (n=60). The second part describes the design of several sets of PCR primers for generating DNA amplification products from closely and distantly related NPVs. These PCR primers were designed from published DNA sequence data and from randomly cloned genomic DNA fragments isolated from a reference H. armigera SNPV (HaSNPV) isolate. The final part of the method describes how specific PCR products when digested with specific restriction endonuclease enzymes, can be used to generate diagnostic DNA profiles (haplotypes) that can be used both to identify heterologous NPVs e.g. Autographa californica MNPV and related viruses, and to differentiate genotypic variants of Helicoverpa SNPV. In the latter case, only two PCR products and four restriction digests were required to differentiate a reference set of 10 Helicoverpa SNPV isolates known to differ 0.1--3.5% at the nucleotide level. The diagnostic method described below marks the second part of a two-phase quantitative-diagnostic protocol that is now being applied to a variety of ecological investigations. In particular, its application should lead to a significant improvement in our understanding of the distribution and population genetics of Helicoverpa SNPVs in the Australian environment, as well as providing a sound basis for the design of pre- and post-release monitoring systems for genetically enhanced bioinsecticides. It is also likely that this method can be adapted readily to the study of other insect pathogen associations important economically.
Examination and Treatment of Hamstring Related Injuries
2012-01-01
Context: There is a wide spectrum of hamstring-related injuries that can occur in the athlete. Accurate diagnosis is imperative to prevent delayed return to sport, injury recurrence, and accurate clinical decision making regarding the most efficacious treatment. Evidence Acquisition: This review highlights current evidence related to the diagnosis and treatment of hamstring-related injuries in athletes. Data sources were limited to peer-reviewed publications indexed in MEDLINE from 1988 through May 2011. Results: An accurate diagnostic process for athletes with posterior thigh–related complaints should include a detailed and discriminative history, followed by a thorough clinical examination. Diagnostic imaging should be utilized when considering hamstring avulsion or ischial apophyseal avulsion. Diagnostic imaging may also be needed to further define the cause of referred posterior thigh pain. Conclusions: Differentiating acute hamstring strains, hamstring tendon avulsions, ischial apophyseal avulsions, proximal hamstring tendinopathies, and referred posterior thigh pain is critical in determining the most appropriate treatment and expediting safe return to play. PMID:23016076
The relative frequency of common neuromuscular diagnoses in a reference center.
Cotta, Ana; Paim, Júlia Filardi; Carvalho, Elmano; da-Cunha-Júnior, Antonio Lopes; Navarro, Monica M; Valicek, Jaquelin; Menezes, Miriam Melo; Nunes, Simone Vilela; Xavier-Neto, Rafael; Baptista, Sidney; Lima, Luciano Romero; Takata, Reinaldo Issao; Vargas, Antonio Pedro
2017-11-01
The diagnostic procedure in neuromuscular patients is complex. Knowledge of the relative frequency of neuromuscular diseases within the investigated population is important to allow the neurologist to perform the most appropriate diagnostic tests. To report the relative frequency of common neuromuscular diagnoses in a reference center. A 17-year chart review of patients with suspicion of myopathy. Among 3,412 examinations, 1,603 (46.98%) yielded confirmatory results: 782 (48.78%) underwent molecular studies, and 821 (51.21%) had muscle biopsies. The most frequent diagnoses were: dystrophinopathy 460 (28.70%), mitochondriopathy 330 (20.59%), spinal muscular atrophy 158 (9.86%), limb girdle muscular dystrophy 157 (9.79%), Steinert myotonic dystrophy 138 (8.61%), facioscapulohumeral muscular dystrophy 99 (6.17%), and other diagnoses 261 (16.28%). Using the presently-available diagnostic techniques in this service, a specific limb girdle muscular dystrophy subtype diagnosis was reached in 61% of the patients. A neuromuscular-appropriate diagnosis is important for genetic counseling, rehabilitation orientation, and early treatment of respiratory and cardiac complications.
Müller, Kai W.
2017-01-01
The inclusion of Internet Gaming Disorder as a preliminary diagnosis subsumed in Section III of the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) has provoked mixed reactions. On the one hand, it has been appreciated as an important sign stressing the negative health-related impact of that disorder. Likewise, the definition of diagnostic criteria helps scientists and clinicians to refer to mandatory indicators associated with a health problem. On the other hand, it has been objected that this new diagnosis bears the danger of pathologizing normal behaviors that are a feature of healthy recreational activity for many people. However, the existence of diagnostic criteria is meant to avoid this danger. This emphasizes the necessity of being able to refer to as accurate defined criteria as possible. In its current version, the DSM criteria display not only strengths but also ambiguities. Both types will be discussed and necessary ideas to resolve those ambiguities will be presented for further research. PMID:28301966
2013-01-01
Background Persistent digestive disorders account for considerable disease burden in the tropics. Despite advances in understanding acute gastrointestinal infections, important issues concerning epidemiology, diagnosis, treatment and control of most persistent digestive symptomatologies remain to be elucidated. Helminths and intestinal protozoa are considered to play major roles, but the full extent of the aetiologic spectrum is still unclear. We provide an overview of pathogens causing digestive disorders in the tropics and evaluate available reference tests. Methods We searched the literature to identify pathogens that might give rise to persistent diarrhoea, chronic abdominal pain and/or blood in the stool. We reviewed existing laboratory diagnostic methods for each pathogen and stratified them by (i) microscopy; (ii) culture techniques; (iii) immunological tests; and (iv) molecular methods. Pathogen-specific reference tests providing highest diagnostic accuracy are described in greater detail. Results Over 30 pathogens may cause persistent digestive disorders. Bacteria, viruses and parasites are important aetiologic agents of acute and long-lasting symptomatologies. An integrated approach, consisting of stool culture, microscopy and/or specific immunological techniques for toxin, antigen and antibody detection, is required for accurate diagnosis of bacteria and parasites. Molecular techniques are essential for sensitive diagnosis of many viruses, bacteria and intestinal protozoa, and are increasingly utilised as adjuncts for helminth identification. Conclusions Diagnosis of the broad spectrum of intestinal pathogens is often cumbersome. There is a need for rapid diagnostic tests that are simple and affordable for resource-constrained settings, so that the management of patients suffering from persistent digestive disorders can be improved. PMID:23347408
Kopkow, Christian; Freiberg, Alice; Kirschner, Stephan; Seidler, Andreas; Schmitt, Jochen
2013-11-01
Systematic literature review. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of posterior cruciate ligament (PCL) tear. Rupture of the PCL is a severe knee injury that can lead to delayed rehabilitation, instability, or chronic knee pathologies. To our knowledge, there is currently no systematic review of studies on the diagnostic accuracy of clinical examination tests to evaluate the integrity of the PCL. A comprehensive systematic literature search was conducted in MEDLINE from 1946, Embase from 1974, and the Allied and Complementary Medicine Database from 1985 until April 30, 2012. Studies were considered eligible if they compared the results of physical examination tests performed in the context of a PCL physical examination to those of a reference standard (arthroscopy, arthrotomy, magnetic resonance imaging). Methodological quality assessment was performed by 2 independent reviewers using the revised version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The search strategy revealed 1307 articles, of which 11 met the inclusion criteria for this review. In these studies, 11 different physical examination tests were identified. Due to differences in study types, different patient populations, and methodological quality, meta-analysis was not indicated. Presently, most physical examination tests have not been evaluated sufficiently enough to be confident in their ability to either confirm or rule out a PCL tear. The diagnostic accuracy of physical examination tests to assess the integrity of the PCL is largely unknown. There is a strong need for further research in this area. Level of Evidence Diagnosis, level 3a.
Hsieh, Ying-Hsin; Wang, Yun F; Moura, Hercules; Miranda, Nancy; Simpson, Steven; Gowrishankar, Ramnath; Barr, John; Kerdahi, Khalil; Sulaiman, Irshad M
2018-05-01
Campylobacteriosis is an infectious gastrointestinal disease caused by Campylobacter spp. In most cases, it is either underdiagnosed or underreported due to poor diagnostics and limited databases. Several DNA-based molecular diagnostic techniques, including 16S ribosomal RNA (rRNA) sequence typing, have been widely used in the species identification of Campylobacter. Nevertheless, these assays are time-consuming and require a high quality of bacterial DNA. Matrix-assisted laser desorption ionization (MALDI) time-of-flight (TOF) MS is an emerging diagnostic technology that can provide the rapid identification of microorganisms by using their intact cells without extraction or purification. In this study, we analyzed 24 American Type Culture Collection reference isolates of 16 Campylobacter spp. and five unknown clinical bacterial isolates for rapid identification utilizing two commercially available MADI-TOF MS platforms, namely the bioMérieux VITEK® MS and Bruker Biotyper systems. In addition, 16S rRNA sequencing was performed to confirm the species-level identification of the unknown clinical isolates. Both MALDI-TOF MS systems identified the isolates of C. jejuni, C. coli, C. lari, and C. fetus. The results of this study suggest that the MALDI-TOF MS technique can be used in the identification of Campylobacter spp. of public health importance.
Vassileva, J; Simeonov, F; Avramova-Cholakova, S
2015-07-01
According to the Bulgarian regulation for radiation protection at medical exposure, the National Centre of Radiobiology and Radiation Protection (NCRRP) is responsible for performing national dose surveys in diagnostic and interventional radiology and nuclear medicine and for establishing of national diagnostic reference levels (DRLs). The next national dose survey is under preparation to be performed in the period of 2015-16, with the aim to cover conventional radiography, mammography, conventional fluoroscopy, interventional and fluoroscopy guided procedures and CT. It will be performed electronically using centralised on-line data collection platform established by the NCRRP. The aim is to increase the response rate and to improve the accuracy by reducing human errors. The concept of the on-line dose data collection platform is presented. Radiological facilities are provided with a tool to determine local typical patient doses, and the NCRRP to establish national DRLs. Future work will include automatic retrieval of dose data from hospital picture archival and communicating system. The on-line data collection platform is expected to facilitate the process of dose audit and optimisation of radiological procedures in Bulgarian hospitals. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Model of critical diagnostic reasoning: achieving expert clinician performance.
Harjai, Prashant Kumar; Tiwari, Ruby
2009-01-01
Diagnostic reasoning refers to the analytical processes used to determine patient health problems. While the education curriculum and health care system focus on training nurse clinicians to accurately recognize and rescue clinical situations, assessments of non-expert nurses have yielded less than satisfactory data on diagnostic competency. The contrast between the expert and non-expert nurse clinician raises the important question of how differences in thinking may contribute to a large divergence in accurate diagnostic reasoning. This article recognizes superior organization of one's knowledge base, using prototypes, and quick retrieval of pertinent information, using similarity recognition as two reasons for the expert's superior diagnostic performance. A model of critical diagnostic reasoning, using prototypes and similarity recognition, is proposed and elucidated using case studies. This model serves as a starting point toward bridging the gap between clinical data and accurate problem identification, verification, and management while providing a structure for a knowledge exchange between expert and non-expert clinicians.
Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results
NASA Technical Reports Server (NTRS)
Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)
2013-01-01
Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.
Genetics Home Reference: macrozoospermia
... Encyclopedia: Semen Analysis MedlinePlus Health Topic: Assisted Reproductive Technology General Information from MedlinePlus (5 links) Diagnostic Tests Drug Therapy Genetic Counseling Palliative Care Surgery and ...
Bereket, Abdullah; Turan, Serap; Omar, Anjumanara; Berber, Mustafa; Ozen, Ahmet; Akbenlioglu, Cengiz; Haklar, Goncagul
2006-01-01
We established age- and sex-related reference ranges for serum insulin-like growth factor-I (IGF-I) and insulin-like growth factor binding protein-3 (IGFBP-3) levels in 807 healthy Turkish children (428 boys, 379 girls), and constructed a model for calculation of standard deviation scores of IGF-I and IGFBP-3 according to age, sex and pubertal stage. Serum IGF-I and IGFBP-3 concentrations tended to be higher in girls compared to boys of the same ages, but the differences were statistically significant only in pubertal ages (9-14 years) for IGF-I and only in prepubertal ages for IGFBP-3 (6-8 years) (p < 0.05). Peak IGF-I concentrations were observed earlier in girls than boys (14 vs. 15 years, Tanner stage IV vs. V) starting to decline thereafter. IGFBP-3 levels peaked at age 13 and at Tanner stage IV in both sexes with a subsequent fall. Serum levels of IGF-I and IGFBP-3 increased steadily with age in the prepubertal stage followed by a rapid increase in IGF-I in the early pubertal stages. A relatively steeper increase in IGF-I but not in IGFBP-3 levels was observed at age 10-11 years in girls and at 12-13 years in boys which preceded the reported age of pubertal growth spurt. At late pubertal stages, both IGF-I and IGFBP-3 either did not change or decreased by increasing age. Interrelationships between growth factors and anthropometric measurements have been described, and the physiologic consequences of these have been discussed in detail. Differences in the pattern of IGF-I and IGFBP-3 in the present paper and those reported in other studies emphasize the importance of locally established reference ranges. Establishment of this reference data and a standard deviation score prediction model based on age, sex and puberty will enhance the diagnostic power and utility of IGF-I and IGFBP-3 in evaluating growth disorders in our population. Copyright 2006 S. Karger AG, Basel
Deeb, Asma; Elfatih, Abubaker
2018-03-01
Hypophosphatasia (HPP) is an inborn error of metabolism with significant morbidity and mortality. Its presentation is nonspecific leading to delayed or missed diagnosis. Low alkaline phosphatase (ALP) is a diagnostic test. Unlike high ALP, low level is commonly not flagged by laboratories as abnormal. A new treatment was shown to be effective in HPP. In this study we aimed to establish the frequency of low ALP levels requiring notification to physicians by the laboratory and also to describe the clinical manifestations of patients presenting with low ALP for a possible diagnosis of HPP. Patients under age 18 years with low ALP levels were identified from biochemistry records over a period of 6 months. Reference ranges were used as per the Associated Regional and University Pathologists Reference Laboratory (Utah, USA). Electronic results for patients with low levels were checked for flagging as abnormal/low ALP results. Charts of identified patients were reviewed. Presenting features were categorized under groups of disorders. ALP levels were tested in 2890 patients. 702 had values less than 160 U/L. Of these patients, 226 (32%) had age/gender specific low ALP. None of the low ALP results was flagged as low. Twenty-one had more than one low reading and their charts were reviewed. Four patients in the neuromuscular and four in the miscellaneous group presented with features consistent with HPP despite these patients having no specific diagnoses. Laboratories do not alert physicians in cases with low ALP levels. A persistently low level in patients with unspecified diagnoses could be a key to diagnose HPP. Implementing lab-specific ranges and alerting for low levels could prompt physicians to investigate for undiagnosed HPP.
Simopoulos, Thomas T; Manchikanti, Laxmaiah; Gupta, Sanjeeva; Aydin, Steve M; Kim, Chong Hwan; Solanki, Daneshvari; Nampiaparampil, Devi E; Singh, Vijay; Staats, Peter S; Hirsch, Joshua A
2015-01-01
The sacroiliac joint is well known as a cause of low back and lower extremity pain. Prevalence estimates are 10% to 25% in patients with persistent axial low back pain without disc herniation, discogenic pain, or radiculitis based on multiple diagnostic studies and systematic reviews. However, at present there are no definitive management options for treating sacroiliac joint pain. To evaluate the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. A systematic review of the diagnostic accuracy and therapeutic effectiveness of sacroiliac joint interventions. The available literature on diagnostic and therapeutic sacroiliac joint interventions was reviewed. The quality assessment criteria utilized were the Quality Appraisal of Reliability Studies (QAREL) checklist for diagnostic accuracy studies, Cochrane review criteria to assess sources of risk of bias, and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment (IPM-QRB) criteria for randomized therapeutic trials and Interventional Pain Management Techniques-Quality Appraisal of Reliability and Risk of Bias Assessment for Nonrandomized Studies (IPM-QRBNR) for observational therapeutic assessments. The level of evidence was based on a best evidence synthesis with modified grading of qualitative evidence from Level I to Level V. Data sources included relevant literature published from 1966 through March 2015 that were identified through searches of PubMed and EMBASE, manual searches of the bibliographies of known primary and review articles, and all other sources. For the diagnostic accuracy assessment, and for the therapeutic modalities, the primary outcome measure of pain relief and improvement in functional status were utilized. A total of 11 diagnostic accuracy studies and 14 therapeutic studies were included. The evidence for diagnostic accuracy is Level II for dual diagnostic blocks with at least 70% pain relief as the criterion standard and Level III evidence for single diagnostic blocks with at least 75% pain relief as the criterion standard. The evidence for cooled radiofrequency neurotomy in managing sacroiliac joint pain is Level II to III. The evidence for conventional radiofrequency neurotomy, intraarticular steroid injections, and periarticular injections with steroids or botulinum toxin is limited: Level III or IV. The limitations of this systematic review include inconsistencies in diagnostic accuracy studies with a paucity of high quality, replicative, and consistent literature. The limitations for therapeutic interventions include variations in technique, variable diagnostic standards for inclusion criteria, and variable results. The evidence for the accuracy of diagnostic and therapeutic effectiveness of sacroiliac joint interventions varied from Level II to Level IV.
ERIC Educational Resources Information Center
Duvekot, Jorieke; van der Ende, Jan; Verhulst, Frank C.; Greaves-Lord, Kirstin
2015-01-01
The screening accuracy of the parent and teacher-reported Social Responsiveness Scale (SRS) was compared with an autism spectrum disorder (ASD) classification according to (1) the Developmental, Dimensional, and Diagnostic Interview (3Di), (2) the Autism Diagnostic Observation Schedule (ADOS), (3) both the 3Di and ADOS, in 186 children referred to…
ERIC Educational Resources Information Center
van Gent, Tiejo; Goedhart, Arnold W.; Treffers, Philip D. A.
2012-01-01
In this study socio-demographic, deafness-related and diagnostic characteristics of hearing impaired children and adolescents referred to a national mental health service for deaf and hard of hearing children and adolescents were examined. Socio-demographic and diagnostic characteristics were compared to corresponding characteristics of hearing…
ERIC Educational Resources Information Center
Meera, S. S.; Kaipa, Ramesh; Thomas, Jaslin; Shivashankar, N.
2013-01-01
Children with communication disorders present with a range of comorbid conditions. Occasionally one of the comorbid conditions manifests so strongly that the primary condition goes unnoticed by the clinician. This tendency to overlook comorbid health problems in the presence of a disability is referred to as diagnostic overshadowing. This is a…
ERIC Educational Resources Information Center
Barbaro, Josephine; Dissanayake, Cheryl
2017-01-01
Autism spectrum disorder diagnoses in toddlers have been established as accurate and stable across time in high-risk siblings and clinic-referred samples. Few studies have investigated diagnostic stability in children prospective identified in community-based settings. Furthermore, there is a dearth of evidence on the individual behaviours that…
Goossens, Joery; Bjerke, Maria; Van Mossevelde, Sara; Van den Bossche, Tobi; Goeman, Johan; De Vil, Bart; Sieben, Anne; Martin, Jean-Jacques; Cras, Patrick; De Deyn, Peter Paul; Van Broeckhoven, Christine; van der Zee, Julie; Engelborghs, Sebastiaan
2018-03-20
We explored the diagnostic performance of cerebrospinal fluid (CSF) biomarkers in allowing differentiation between frontotemporal lobar degeneration (FTLD) and Alzheimer's disease (AD), as well as between FTLD pathological subtypes. CSF levels of routine AD biomarkers (phosphorylated tau (p-tau 181 ), total tau (t-tau), and amyloid-beta (Aβ) 1-42 ) and neurofilament proteins, as well as progranulin levels in both CSF and serum were quantified in definite FTLD (n = 46), clinical AD (n = 45), and cognitively healthy controls (n = 20). FTLD subgroups were defined by genetic carrier status and/or postmortem neuropathological confirmation (FTLD-TDP: n = 34, including FTLD-C9orf72: n = 19 and FTLD-GRN: n = 9; FTLD-tau: n = 10). GRN mutation carriers had significantly lower progranulin levels compared to other FTLD patients, AD, and controls. Both t-tau and p-tau 181 were normal in FTLD patients, even in FTLD-tau. Aβ 1-42 levels were very variable in FTLD. Neurofilament light chain (Nf-L) was significantly higher in FTLD compared with AD and controls. The reference logistic regression model based on the established AD biomarkers could be improved by the inclusion of CSF Nf-L, which was also important for the differentiation between FTLD and controls. Within the FTLD cohort, no significant differences were found between FTLD-TDP and FTLD-tau, but GRN mutation carriers had higher t-tau and Nf-L levels than C9orf72 mutation carriers and FTLD-tau patients. There is an added value for Nf-L in the differential diagnosis of FTLD. Progranulin levels in CSF depend on mutation status, and GRN mutation carriers seem to be affected by more severe neurodegeneration.
[Peripheral lymphadenopathy in childhood--recommendations for diagnostic evaluation].
Benesch, M; Kerbl, R; Wirnsberger, A; Stünzner, D; Mangge, H; Schenkeli, R; Deutsch, J
2000-01-01
Enlargement of peripheral lymph nodes most commonly caused by a local inflammatory process is frequently seen in childhood. The aim of the present study was to analyze the most common causes of peripheral lymphadenopathy and to develop a simple algorithm for the primary diagnostic evaluation of peripheral lymph node enlargement in this age group. Between April and September 1999 87 unselected children (median age: 5 1/2 years) with peripheral lymphadenopathy were referred to the Department of Pediatrics, University of Graz, for further investigation. EBV infection was diagnosed in 20 (23.0%) children. 19 (21.8%) patients had acute bacterial lymphadenitis. In 21 (24.1%) patients lymph node enlargement was classified as "post/parainfectious (viral)". Four patients each had toxoplasmosis and cat scratch disease. In 11 (12.6%) patients neither physical nor laboratory examinations revealed pathologic results. Among the remaining 8 children sarcoidosis and Hodgkin disease was diagnosed in one patient each. Small, soft, mobile, nontender, cervical, axillary or inguinal lymph nodes do not require further investigations. In case of enlarged, tender lymph nodes with overlying skin erythema and fever diagnostic evaluation should include complete blood count, erythrocyte sedimentation rate and/or c-reactive protein level, supplemented by appropriate antibody testing (EBV, CMV, Toxoplasma gondii, Bartonella henselae). Firm, enlarged, painless lymph nodes which are matted together and fixed to the skin or underlying tissues necessitate a more detailed diagnostic evaluation in order to exclude malignant or granulomatous diseases. Our study demonstrated that primary diagnostic evaluation of childhood peripheral lymphadenopathy is mainly based on clinical grounds. In most cases a small number of additionally performed laboratory tests allow to correctly identify the cause of the peripheral lymph node enlargement.
Hall, Charlotte L; Walker, Gemma M; Valentine, Althea Z; Guo, Boliang; Kaylor-Hughes, Catherine; James, Marilyn; Daley, David; Sayal, Kapil; Hollis, Chris
2014-12-01
The National Institute for Health and Care Excellence (NICE) guidelines for attention deficit/hyperactivity disorder (ADHD) state that young people need to have access to the best evidence-based care to improve outcome. The current 'gold standard' ADHD diagnostic assessment combines clinical observation with subjective parent, teacher and self-reports. In routine practice, reports from multiple informants may be unavailable or contradictory, leading to diagnostic uncertainty and delay. The addition of objective tests of attention and activity may help reduce diagnostic uncertainty and delays in initiating treatment leading to improved outcomes. This trial investigates whether providing clinicians with an objective report of levels of attention, impulsivity and activity can lead to an earlier, and more accurate, clinical diagnosis and improved patient outcome. This multisite randomised controlled trial will recruit young people (aged 6-17 years old) who have been referred for an ADHD diagnostic assessment at Child and Adolescent Mental Health Services (CAMHS) and Community Paediatric clinics across England. Routine clinical assessment will be augmented by the QbTest, incorporating a continuous performance test (CPT) and infrared motion tracking of activity. The participant will be randomised into one of two study arms: QbOpen (clinician has immediate access to a QbTest report): QbBlind (report is withheld until the study end). Primary outcomes are time to diagnosis and diagnostic accuracy. Secondary outcomes include clinician's diagnostic confidence and routine clinical outcome measures. Cost-effective analysis will be conducted, alongside a qualitative assessment of the feasibility and acceptability of incorporating QbTest in routine practice. The findings from the study will inform commissioners, clinicians and managers about the feasibility, acceptability, clinical utility and cost-effectiveness of incorporating QbTest into routine diagnostic assessment of young people with ADHD. The results will be submitted for publication in peer-reviewed journals. The study has received ethical approval. NCT02209116. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
van Rumund, Anouke; Aerts, Marjolein B; Esselink, Rianne A J; Meijer, Frederick J A; Verbeek, Marcel M; Bloem, Bastiaan R
2018-05-16
Differentiation of Parkinson's disease (PD) from the various types of atypical parkinsonism (AP) such as multiple system atrophy (MSA), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB), corticobasal syndrome (CBS) and vascular parkinsonism (VP), can be challenging, especially early in the disease course when symptoms overlap. A major unmet need in the diagnostic workup of these disorders is a diagnostic tool that differentiates the various disorders, preferably in the earliest disease stages when the clinical presentation is similar. Many diagnostic tests have been evaluated, but their added value was studied mostly in retrospective case-control studies that included patients with a straightforward clinical diagnosis. Here, we describe the design of a prospective cohort study in patients with parkinsonism in an early disease stage who have an uncertain clinical diagnosis. Our aim is to evaluate the diagnostic accuracy of (1) detailed clinical examination by a movement disorder specialist, (2) magnetic resonance imaging (MRI) techniques and (3) cerebrospinal fluid (CSF) biomarkers. Patients with parkinsonism with an uncertain clinical diagnosis and a disease course less than three years will be recruited. Patients will undergo extensive neurological examination, brain MRI including conventional and advanced sequences, and a lumbar puncture. The diagnosis (including level of certainty) will be defined by a movement disorders expert, neuroradiologist and neurochemist based on clinical data, MRI results and CSF results, respectively. The clinical diagnosis after three years' follow-up will serve as the "gold standard" reference diagnosis, based on consensus criteria and as established by two movement disorder specialists (blinded to the test results). Diagnostic accuracy of individual instruments and added value of brain MRI and CSF analysis after evaluation by a movement disorder expert will be calculated, expressed as the change in percentage of individuals that are correctly diagnosed with PD or AP. This study will yield new insights into the diagnostic value of clinical evaluation by a movement disorder specialist, brain MRI and CSF analysis in discriminating PD from AP in early disease stages. The outcome has the potential to help clinicians in choosing the optimal diagnostic strategy for patients with an uncertain clinical diagnosis. NCT01249768, registered November 26 2010.
Hall, Charlotte L; Walker, Gemma M; Valentine, Althea Z; Guo, Boliang; Kaylor-Hughes, Catherine; James, Marilyn; Daley, David; Sayal, Kapil; Hollis, Chris
2014-01-01
Introduction The National Institute for Health and Care Excellence (NICE) guidelines for attention deficit/hyperactivity disorder (ADHD) state that young people need to have access to the best evidence-based care to improve outcome. The current ‘gold standard’ ADHD diagnostic assessment combines clinical observation with subjective parent, teacher and self-reports. In routine practice, reports from multiple informants may be unavailable or contradictory, leading to diagnostic uncertainty and delay. The addition of objective tests of attention and activity may help reduce diagnostic uncertainty and delays in initiating treatment leading to improved outcomes. This trial investigates whether providing clinicians with an objective report of levels of attention, impulsivity and activity can lead to an earlier, and more accurate, clinical diagnosis and improved patient outcome. Methods and analysis This multisite randomised controlled trial will recruit young people (aged 6–17 years old) who have been referred for an ADHD diagnostic assessment at Child and Adolescent Mental Health Services (CAMHS) and Community Paediatric clinics across England. Routine clinical assessment will be augmented by the QbTest, incorporating a continuous performance test (CPT) and infrared motion tracking of activity. The participant will be randomised into one of two study arms: QbOpen (clinician has immediate access to a QbTest report): QbBlind (report is withheld until the study end). Primary outcomes are time to diagnosis and diagnostic accuracy. Secondary outcomes include clinician's diagnostic confidence and routine clinical outcome measures. Cost-effective analysis will be conducted, alongside a qualitative assessment of the feasibility and acceptability of incorporating QbTest in routine practice. Ethics and dissemination The findings from the study will inform commissioners, clinicians and managers about the feasibility, acceptability, clinical utility and cost-effectiveness of incorporating QbTest into routine diagnostic assessment of young people with ADHD. The results will be submitted for publication in peer-reviewed journals. The study has received ethical approval. Trial registration number NCT02209116. PMID:25448628
Sarkar, Rajarshi
2013-07-01
The validity of the entire renal function tests as a diagnostic tool depends substantially on the Biological Reference Interval (BRI) of urea. Establishment of BRI of urea is difficult partly because exclusion criteria for selection of reference data are quite rigid and partly due to the compartmentalization considerations regarding age and sex of the reference individuals. Moreover, construction of Biological Reference Curve (BRC) of urea is imperative to highlight the partitioning requirements. This a priori study examines the data collected by measuring serum urea of 3202 age and sex matched individuals, aged between 1 and 80 years, by a kinetic UV Urease/GLDH method on a Roche Cobas 6000 auto-analyzer. Mann-Whitney U test of the reference data confirmed the partitioning requirement by both age and sex. Further statistical analysis revealed the incompatibility of the data for a proposed parametric model. Hence the data was non-parametrically analysed. BRI was found to be identical for both sexes till the 2(nd) decade, and the BRI for males increased progressively 6(th) decade onwards. Four non-parametric models were postulated for construction of BRC: Gaussian kernel, double kernel, local mean and local constant, of which the last one generated the best-fitting curves. Clinical decision making should become easier and diagnostic implications of renal function tests should become more meaningful if this BRI is followed and the BRC is used as a desktop tool in conjunction with similar data for serum creatinine.
Differential Diagnosis of Hispanic Children Referred for Autism Spectrum Disorders: Complex Issues
ERIC Educational Resources Information Center
Overton, Terry; Fielding, Cheryl; Alba, Roman
2007-01-01
This study examines the decision-making process used for differential diagnosis of a sample of Hispanic children referred for autism spectrum disorders (ASDs). Of the sample of 28 children, 18 were diagnosed with ASDs. Of the 10 children who were not diagnosed with ASDs, 80% were found to have multiple diagnostic labels or comorbidities.…
Autism Spectrum Disorder in the Second Year: Stability and Change in Syndrome Expression
ERIC Educational Resources Information Center
Chawarska, Katarzyna; Klin, Ami; Paul, Rhea; Volkmar, Fred
2007-01-01
Objectives: Increasing numbers of young children referred for a differential diagnosis of autism spectrum disorders (ASD) necessitates better understanding of the early syndrome expression and the utility of the existing state-of-the art diagnostic methods in this population. Method: Out of 31 infants under the age of 2 years referred for a…
A Prospective Study of Toddlers with ASD: Short-Term Diagnostic and Cognitive Outcomes
ERIC Educational Resources Information Center
Chawarska, Katarzyna; Klin, Ami; Paul, Rhea; Macari, Suzanne; Volkmar, Fred
2009-01-01
Background: Despite recent increases in the number of toddlers referred for a differential diagnosis of autism spectrum disorders (ASD), knowledge of short-term stability of the early diagnosis as well as cognitive outcomes in this cohort is still limited. Method: Cognitive, social, and communication skills of 89 clinic-referred toddlers were…
D-dimer test for excluding the diagnosis of pulmonary embolism.
Crawford, Fay; Andras, Alina; Welch, Karen; Sheares, Karen; Keeling, David; Chappell, Francesca M
2016-08-05
Pulmonary embolism (PE) can occur when a thrombus (blood clot) travels through the veins and lodges in the arteries of the lungs, producing an obstruction. People who are thought to be at risk include those with cancer, people who have had a recent surgical procedure or have experienced long periods of immobilisation and women who are pregnant. The clinical presentation can vary, but unexplained respiratory symptoms such as difficulty breathing, chest pain and an increased respiratory rate are common.D-dimers are fragments of protein released into the circulation when a blood clot breaks down as a result of normal body processes or with use of prescribed fibrinolytic medication. The D-dimer test is a laboratory assay currently used to rule out the presence of high D-dimer plasma levels and, by association, venous thromboembolism (VTE). D-dimer tests are rapid, simple and inexpensive and can prevent the high costs associated with expensive diagnostic tests. To investigate the ability of the D-dimer test to rule out a diagnosis of acute PE in patients treated in hospital outpatient and accident and emergency (A&E) settings who have had a pre-test probability (PTP) of PE determined according to a clinical prediction rule (CPR), by estimating the accuracy of the test according to estimates of sensitivity and specificity. The review focuses on those patients who are not already established on anticoagulation at the time of study recruitment. We searched 13 databases from conception until December 2013. We cross-checked the reference lists of relevant studies. Two review authors independently applied exclusion criteria to full papers and resolved disagreements by discussion.We included cross-sectional studies of D-dimer in which ventilation/perfusion (V/Q) scintigraphy, computerised tomography pulmonary angiography (CTPA), selective pulmonary angiography and magnetic resonance pulmonary angiography (MRPA) were used as the reference standard.• Adults who were managed in hospital outpatient and A&E settings and were suspected of acute PE were eligible for inclusion in the review if they had received a pre-test probability score based on a CPR.• quantitative, semi quantitative and qualitative D-dimer tests.• Target condition: acute symptomatic PE.• Reference standards: We included studies that used pulmonary angiography, V/Q scintigraphy, CTPA and MRPA as reference standard tests. Two review authors independently extracted data and assessed quality using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). We resolved disagreements by discussion. Review authors extracted patient-level data when available to populate 2 × 2 contingency tables (true-positives (TPs), true-negatives (TNs), false-positives (FPs) and false-negatives (FNs)). We included four studies in the review (n = 1585 patients). None of the studies were at high risk of bias in any of the QUADAS-2 domains, but some uncertainty surrounded the validity of studies in some domains for which the risk of bias was uncertain. D-dimer assays demonstrated high sensitivity in all four studies, but with high levels of false-positive results, especially among those over the age of 65 years. Estimates of sensitivity ranged from 80% to 100%, and estimates of specificity from 23% to 63%. A negative D-dimer test is valuable in ruling out PE in patients who present to the A&E setting with a low PTP. Evidence from one study suggests that this test may have less utility in older populations, but no empirical evidence was available to support an increase in the diagnostic threshold of interpretation of D-dimer results for those over the age of 65 years.
Wu, Mixia; Zhang, Dianchen; Liu, Aiyi
2016-01-01
New biomarkers continue to be developed for the purpose of diagnosis, and their diagnostic performances are typically compared with an existing reference biomarker used for the same purpose. Considerable amounts of research have focused on receiver operating characteristic curves analysis when the reference biomarker is dichotomous. In the situation where the reference biomarker is measured on a continuous scale and dichotomization is not practically appealing, an index was proposed in the literature to measure the accuracy of a continuous biomarker, which is essentially a linear function of the popular Kendall's tau. We consider the issue of estimating such an accuracy index when the continuous reference biomarker is measured with errors. We first investigate the impact of measurement errors on the accuracy index, and then propose methods to correct for the bias due to measurement errors. Simulation results show the effectiveness of the proposed estimator in reducing biases. The methods are exemplified with hemoglobin A1c measurements obtained from both the central lab and a local lab to evaluate the accuracy of the mean data obtained from the metered blood glucose monitoring against the centrally measured hemoglobin A1c from a behavioral intervention study for families of youth with type 1 diabetes.
Duszak, Richard; Berlin, Leonard
2010-06-01
Plaintiff's Attorney (Pl Att:: Doctor, the record shows that the patient was referred to the hospital's radiology department by her gynecologist for a screening mammogram. The record also shows that when completing the mammography information form, the patient wrote that she had a lump in her left breast, correct? Defendant Radiologist (Df Ra:): Yes. Pl Att: But your technologist performed, and you interpreted, a screening mammogram. Doesn't the radiology standard of care require you to do a diagnostic mammogram when the patient has a breast lump? Df Ra:: Well, normally yes, but if it's going to be a diagnostic mammogram, then the referring physician has to order it. In this case our tech called the gynecologist and asked him whether he wanted to order a diagnostic study, and he said no, he didn't feel the lump, and that we should only do a plain screening mammogram. Pl Att:: Please explain something. You're agreeing that a woman with a breast lump should have a diagnostic mammogram, but you are saying that you didn't do one because the patient's physician wouldn't order it? Don't you have a duty to do the diagnostic mammogram in a case like this on your own, without having to ask permission from the patient's gynecologist? Df Ra:: Only the treating physician can change a screening mammogram into a diagnostic mammogram, and I am not the treating physician. If I went ahead and did a diagnostic mammography examination on my own, it would be Medicare fraud, and our hospital's compliance officer says it could result in our hospital being fined and thrown out of the Medicare program. Pl Atty: What prevents you then from recommending-not ordering, but just recommending-a diagnostic mammogram in your report, because the patient says she's got a lump? Df Rad: Well, according to our hospital's compliance officer, that would also be fraud.
Weiss, Jakob; Martirosian, Petros; Notohamiprodjo, Mike; Kaufmann, Sascha; Othman, Ahmed E; Grosse, Ulrich; Nikolaou, Konstantin; Gatidis, Sergios
2018-03-01
The aims of this study were to establish a 5-minute magnetic resonance (MR) screening protocol for prostate cancer in men before biopsy and to evaluate effects on Prostate Imaging Reporting and Data System (PI-RADS) V2 scoring in comparison to a conventional, fully diagnostic multiparametric MR imaging (mpMRI) approach. Fifty-two patients with elevated prostate-specific antigen levels and without prior biopsy were prospectively included in this institutional review board-approved study. In all patients, an mpMRI protocol according to the PI-RADS recommendations was acquired on a 3 T MRI system. In addition, an accelerated diffusion-weighted imaging sequence was acquired using simultaneous multislice technique (DW-EPISMS). Two readers independently evaluated the images for the presence/absence of prostate cancer according to the PI-RADS criteria and for additional findings. In a first reading session, only the screening protocol consisting of axial T2-weighted and DW-EPISMS images was made available. In a subsequent reading session, the mpMRI protocol was assessed blinded to the results of the first reading, serving as reference standard. Both readers successfully established a final diagnosis according to the PI-RADS criteria in the screening and mpMRI protocol. Mean lesion size was 1.2 cm in the screening and 1.4 cm in the mpMRI protocol (P = 0.4) with 35% (18/52) of PI-RADS IV/V lesions. Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100% for both readers with no significant differences in comparison to the mpMRI standard (P = 1.0). In 3 patients, suspicious lymph nodes were reported as additional finding, which were equally detectable in the screening and mpMRI protocol. A 5-minute MR screening protocol for prostate cancer in men with elevated prostate-specific antigen levels before biopsy is applicable for clinical routine with similar diagnostic performance as the full diagnostic mpMRI approach.
Zelazowska-Rutkowska, Beata; Trusiak, Marta; Bossowski, Artur; Cylwik, Bogdan
2018-05-01
Pituitary dwarfism (also known as short stature) is a medical condition in which the pituitary gland does not produce enough growth hormone (GH). To confirm the diagnosis of growth hormone deficiency the overnight profile of GH secretion and GH provocative tests are usually performed; however, due to wide GH fluctuations throughout the day and night and the invasiveness of stimulation tests, their clinical utility is limited. Therefore, screening for IGF-1 (insulin-like growth factor 1) and IGFBP-3 (insulin-like growth factor binding protein type 3) is proposed, suggesting that these tests provide a more accurate reflection of the mean plasma GH level, although the results of these tests are still problematic. In this context, the aim of this study was to assess the diagnostic usefulness of IGF-1 and IGFBP-3 in children with suspected pituitary dwarfism. Studies were carried out in 127 children with abnormal growth and low spontaneous 24-hour plasma GH profiles and abnormal results of GH stimulation tests. Fasting serum IGF-1 and IGFBP-3 were determined by chemiluminescent quantitative measurement using the IMMULITE 1000 IGF-1 and IGFBP-3 kits (Siemens Healthcare Diagnostics, United Kingdom) on the IMMULITE 1000 analyzer (Siemens Healthcare Diagnostics, USA). Results were compared to the normal range by children's age. Mean serum IGF-1 concentrations were within the lower normal range (41.7% cases), and 58.3% results were below the normal reference range in the study group. The average serum IGFBP-3 levels were within the lower normal range. We conclude that IGF-1 test can be a useful tool in the diagnosis of pituitary dwarfism in children suspected of this condition, but due to relatively poor sensitivity the testing cannot be performed alone, but in combination with other tests. The IGFBP-3 test is not useful for the diagnosis of this disease.
Arculeo, Marco; Bonello, Juan J.; Bonnici, Leanne; Cannas, Rita; Carbonara, Pierluigi; Cau, Alessandro; Charilaou, Charis; El Ouamari, Najib; Fiorentino, Fabio; Follesa, Maria Cristina; Garofalo, Germana; Golani, Daniel; Guarniero, Ilaria; Hanner, Robert; Hemida, Farid; Kada, Omar; Lo Brutto, Sabrina; Mancusi, Cecilia; Morey, Gabriel; Schembri, Patrick J.; Serena, Fabrizio; Sion, Letizia; Stagioni, Marco; Tursi, Angelo; Vrgoc, Nedo; Steinke, Dirk; Tinti, Fausto
2017-01-01
Cartilaginous fish are particularly vulnerable to anthropogenic stressors and environmental change because of their K-selected reproductive strategy. Accurate data from scientific surveys and landings are essential to assess conservation status and to develop robust protection and management plans. Currently available data are often incomplete or incorrect as a result of inaccurate species identifications, due to a high level of morphological stasis, especially among closely related taxa. Moreover, several diagnostic characters clearly visible in adult specimens are less evident in juveniles. Here we present results generated by the ELASMOMED Consortium, a regional network aiming to sample and DNA-barcode the Mediterranean Chondrichthyans with the ultimate goal to provide a comprehensive DNA barcode reference library. This library will support and improve the molecular taxonomy of this group and the effectiveness of management and conservation measures. We successfully barcoded 882 individuals belonging to 42 species (17 sharks, 24 batoids and one chimaera), including four endemic and several threatened ones. Morphological misidentifications were found across most orders, further confirming the need for a comprehensive DNA barcoding library as a valuable tool for the reliable identification of specimens in support of taxonomist who are reviewing current identification keys. Despite low intraspecific variation among their barcode sequences and reduced samples size, five species showed preliminary evidence of phylogeographic structure. Overall, the ELASMOMED initiative further emphasizes the key role accurate DNA barcoding libraries play in establishing reliable diagnostic species specific features in otherwise taxonomically problematic groups for biodiversity management and conservation actions. PMID:28107413
Jones, Danielle; Drew, Paul; Elsey, Christopher; Blackburn, Daniel; Wakefield, Sarah; Harkness, Kirsty; Reuber, Markus
2016-01-01
In the UK dementia is under-diagnosed, there is limited access to specialist memory clinics, and many of the patients referred to such clinics are ultimately found to have functional (non-progressive) memory disorders (FMD), rather than a neurodegenerative disorder. Government initiatives on 'timely diagnosis' aim to improve the rate and quality of diagnosis for those with dementia. This study seeks to improve the screening and diagnostic process by analysing communication between clinicians and patients during initial specialist clinic visits. Establishing differential conversational profiles could help the timely differential diagnosis of memory complaints. This study is based on video- and audio recordings of 25 initial consultations between neurologists and patients referred to a UK memory clinic. Conversation analysis was used to explore recurrent communicative practices associated with each diagnostic group. Two discrete conversational profiles began to emerge, to help differentiate between patients with dementia and functional memory complaints, based on (1) whether the patient is able to answer questions about personal information; (2) whether they can display working memory in interaction; (3) whether they are able to respond to compound questions; (4) the time taken to respond to questions; and (5) the level of detail they offer when providing an account of their memory failure experiences. The distinctive conversational profiles observed in patients with functional memory complaints on the one hand and neurodegenerative memory conditions on the other suggest that conversational profiling can support the differential diagnosis of functional and neurodegenerative memory disorders.
Romeiro Lopes, Tiara Cristina; Gravena, Angela Andréia França; Demitto, Marcela de Oliveira; Borghesan, Deise Helena Pelloso; Dell`Agnolo, Cátia Millene; Brischiliari, Sheila Cristina Rocha; Carvalho, Maria Dalva de Barros; Pelloso, Sandra Marisa
2017-11-26
Background: Cancer is a major public health problem. Early diagnosis and treatment are essential for reducing mortality. This study aimed to analyze factors associated with delay in breast cancer diagnosis and treatment among women attending a reference cancer service. Methods: This retrospective, cross-sectional study was performed with data collected from medical records and interviews conducted with women diagnosed with breast cancer and treated from October 2013 to October 2014 at a cancer reference hospital in Paraná, Southern Brazil. Results: A total of 82 participants were enrolled during the study period; their average age was 58.2 ± 11.5 years. The average time taken for final diagnosis of breast cancer was 102.5 ± 165.5 days. Treatment onset was delayed in the majority of cases, and the average time elapsing from diagnostic biopsy to onset of primary treatment was 72.3 ± 54.0 days. The odds of treatment delay were higher among the women with a low educational level. Conclusions: The results underline the need for proposals aimed at early detection, identification of risk factors and timely provision of treatment by health managers that focus on this group. Creative Commons Attribution License
NASA Technical Reports Server (NTRS)
Deininger, William D.; Vondra, Robert J.
1987-01-01
The design and performance of an arcjet nuclear-electric-propulsion spacecraft, suitable for use in the Space Nuclear Power System (SNPS) reference mission, are outlined. The vehicle design was based on a 30-kW ammonia arcjet system operating at an Isp of 1050 s and an efficiency of 45 percent. The arcjet/gimbal system, power-processing unit, and propellant-feed system are described. A 100-kWe SNPS was assumed, and the spacecraft mass was baselined at 5250 kg (excluding the propellant-feed system). A radiation/arcjet efflux diagnostics package was included in the performance analysis. This spacecraft, assuming a Shuttle launch from KSC, can perform a 50-deg inclination change and reach a final orbit of 35,860 km with a 120-d trip time providing a 4-mo active load for the SNPS. Alternatively, a Titan IV launch would provide a mass margin of 120 kg to a 10,000-km, 58-deg final orbit in 74 d. This spacecraft meets the reference-mission constraint of low developmental risk, and is scalable to power levels projected for future space platforms.
Measurement uncertainty: Friend or foe?
Infusino, Ilenia; Panteghini, Mauro
2018-02-02
The definition and enforcement of a reference measurement system, based on the implementation of metrological traceability of patients' results to higher order reference methods and materials, together with a clinically acceptable level of measurement uncertainty, are fundamental requirements to produce accurate and equivalent laboratory results. The uncertainty associated with each step of the traceability chain should be governed to obtain a final combined uncertainty on clinical samples fulfilling the requested performance specifications. It is important that end-users (i.e., clinical laboratory) may know and verify how in vitro diagnostics (IVD) manufacturers have implemented the traceability of their calibrators and estimated the corresponding uncertainty. However, full information about traceability and combined uncertainty of calibrators is currently very difficult to obtain. Laboratory professionals should investigate the need to reduce the uncertainty of the higher order metrological references and/or to increase the precision of commercial measuring systems. Accordingly, the measurement uncertainty should not be considered a parameter to be calculated by clinical laboratories just to fulfil the accreditation standards, but it must become a key quality indicator to describe both the performance of an IVD measuring system and the laboratory itself. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
System theory in medical diagnostic devices: an overview.
Baura, Gail D
2006-01-01
Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.
Gender incongruence: a comparative study using ICD-10 and DSM-5 diagnostic criteria.
Soll, Bianca M; Robles-García, Rebeca; Brandelli-Costa, Angelo; Mori, Daniel; Mueller, Andressa; Vaitses-Fontanari, Anna M; Cardoso-da-Silva, Dhiordan; Schwarz, Karine; Abel-Schneider, Maiko; Saadeh, Alexandre; Lobato, Maria-Inês-Rodrigues
2018-01-01
To compare the presence of criteria listed in the DSM-5 and ICD-10 diagnostic manuals in a Brazilian sample of transgender persons seeking health services specifically for physical transition. This multicenter cross-sectional study included a sample of 103 subjects who sought services for gender identity disorder in two main reference centers in Brazil. The method involved a structured interview encompassing the diagnostic criteria in the two manuals. The results revealed that despite theoretical disagreement about the criteria, the manuals overlap regarding diagnosis confirmation; the DSM-5 was more inclusive (97.1%) than the ICD-10 (93.2%) in this population. Although there is no consensus on diagnostic criteria on transgenderism in the diversity of social and cultural contexts, more comprehensive diagnostic criteria are evolving due to society's increasing inclusivity.
Accuracy of Referring Provider and Endoscopist Impressions of Colonoscopy Indication.
Naveed, Mariam; Clary, Meredith; Ahn, Chul; Kubiliun, Nisa; Agrawal, Deepak; Cryer, Byron; Murphy, Caitlin; Singal, Amit G
2017-07-01
Background: Referring provider and endoscopist impressions of colonoscopy indication are used for clinical care, reimbursement, and quality reporting decisions; however, the accuracy of these impressions is unknown. This study assessed the sensitivity, specificity, positive and negative predictive value, and overall accuracy of methods to classify colonoscopy indication, including referring provider impression, endoscopist impression, and administrative algorithm compared with gold standard chart review. Methods: We randomly sampled 400 patients undergoing a colonoscopy at a Veterans Affairs health system between January 2010 and December 2010. Referring provider and endoscopist impressions of colonoscopy indication were compared with gold-standard chart review. Indications were classified into 4 mutually exclusive categories: diagnostic, surveillance, high-risk screening, or average-risk screening. Results: Of 400 colonoscopies, 26% were performed for average-risk screening, 7% for high-risk screening, 26% for surveillance, and 41% for diagnostic indications. Accuracy of referring provider and endoscopist impressions of colonoscopy indication were 87% and 84%, respectively, which were significantly higher than that of the administrative algorithm (45%; P <.001 for both). There was substantial agreement between endoscopist and referring provider impressions (κ=0.76). All 3 methods showed high sensitivity (>90%) for determining screening (vs nonscreening) indication, but specificity of the administrative algorithm was lower (40.3%) compared with referring provider (93.7%) and endoscopist (84.0%) impressions. Accuracy of endoscopist, but not referring provider, impression was lower in patients with a family history of colon cancer than in those without (65% vs 84%; P =.001). Conclusions: Referring provider and endoscopist impressions of colonoscopy indication are both accurate and may be useful data to incorporate into algorithms classifying colonoscopy indication. Copyright © 2017 by the National Comprehensive Cancer Network.
Flight Plasma Diagnostics for High-Power, Solar-Electric Deep-Space Spacecraft
NASA Technical Reports Server (NTRS)
Johnson, Lee; De Soria-Santacruz Pich, Maria; Conroy, David; Lobbia, Robert; Huang, Wensheng; Choi, Maria; Sekerak, Michael J.
2018-01-01
NASA's Asteroid Redirect Robotic Mission (ARRM) project plans included a set of plasma and space environment instruments, the Plasma Diagnostic Package (PDP), to fulfill ARRM requirements for technology extensibility to future missions. The PDP objectives were divided into the classes of 1) Plasma thruster dynamics, 2) Solar array-specific environmental effects, 3) Plasma environmental spacecraft effects, and 4) Energetic particle spacecraft environment. A reference design approach and interface requirements for ARRM's PDP was generated by the PDP team at JPL and GRC. The reference design consisted of redundant single-string avionics located on the ARRM spacecraft bus as well as solar array, driving and processing signals from multiple copies of several types of plasma, effects, and environments sensors distributed over the spacecraft and array. The reference design sensor types were derived in part from sensors previously developed for USAF Research Laboratory (AFRL) plasma effects campaigns such as those aboard TacSat-2 in 2007 and AEHF-2 in 2012.
Isaza, Ramiro; Wiedner, Ellen; Hiser, Sarah; Cray, Carolyn
2014-09-01
Acute phase protein (APP) immunoassays and serum protein electrophoresis (SPEP) are assays for evaluating the inflammatory response and have use as diagnostic tools in a variety of species. Acute phase proteins are markers of inflammation that are highly conserved across different species while SPEP separates and quantifies serum protein fractions based on their physical properties. In the current study, serum samples from 35 clinically healthy Asian elephants (Elephas maximus) were analyzed using automated assays for C-reactive protein, serum amyloid A, and haptoglobin and SPEP. Robust methods were used to generate reference intervals for the APPs: C-reactive protein (1.3-12.8 mg/l), serum amyloid A (0-47.5 mg/l), and haptoglobin (0-1.10 mg/ml). In addition, SPEP was performed on these samples to establish reference intervals for each protein fraction. A combination of APPs and SPEP measurements are valuable adjunctive diagnostic tools in elephant health care. © 2014 The Author(s).
[The National Reference Centres and Reference Laboratories. Importance and tasks].
Laude, G; Ammon, A
2005-09-01
Since 1995, the German Federal Ministry for Health and Social Security funds National Reference Centres (NRC) for the laboratory surveillance of important pathogens and syndromes. Which pathogens or syndromes are selected to be covered by a NRC depends on their epidemiological relevance, the special diagnostic tools, problems with antimicrobial resistance and necessary infection control measures. Currently, there are 15 NRC, which are appointed for a period of 3 years (currently from January 2005 through December 2007). Towards the end of their appointment all NRC are evaluated by a group of specialists. The assessment of their achievements is guided by a catalogue of tasks for the NRC. In addition to the NRC, a total of 50 laboratories are appointed which provide specialist expertise for additional pathogens in order to have a broad range of pathogens for which specialist laboratories are available. Their predominant task is to give advice and support for special diagnostic problems. Both NRC and the specialist laboratories are important parts of the network for infectious disease epidemiology.
El-Shafey, A; Kassab, A
2013-04-01
The purpose of the present study was to provide a detailed computed tomography (CT) and cross-sectional anatomic reference of the normal metatarsus and digits for the camel and buffalo, as well as to compare between metatarsus and digits in these animals to outstand a basis for diagnosis of their diseases. Advantages, including depiction of detailed cross-sectional anatomy, improved contrast resolution and computer reformatting, make it a potentially valuable diagnostic technique. The hind limbs of 12 healthy adult camel and buffalo were used. Clinically relevant anatomic structures were identified and labelled at each level in the corresponding images (CT and anatomic slices). CT images were used to identify the bony and soft tissue structures of the metatarsus and digits. The knowledge of normal anatomy of the camel and buffalo metatarsus and digits would serve as initial reference to the evaluation of CT images in these species. © 2012 Blackwell Verlag GmbH.
Feeding problems of infants and toddlers
Bernard-Bonnin, Anne-Claude
2006-01-01
OBJECTIVE To propose a diagnostic and therapeutic approach to feeding problems in early childhood. QUALITY OF EVIDENCE Articles were retrieved through a MEDLINE search from January 1990 to December 2005 using the MeSH terms eating disorders, infant, and child. Recommended practice is based mainly on levels II and III evidence. MAIN MESSAGE Feeding problems are classified under structural abnormalities, neurodevelopmental disabilities, and behavioural disorders, with overlap between categories. A medical approach also needs an evaluation of diet and an assessment of the interaction between parent and child. Treating medical or surgical conditions, increasing caloric intake, and counseling about general nutrition can alleviate mild to moderate problems. More complicated cases should be referred to multidisciplinary teams. Behavioural therapy aims to foster appropriate behaviour and discourage maladaptive behaviour. CONCLUSION Feeding problems in early childhood often have multifactorial causes and a substantial behavioural component. Family physicians have a key role in detecting problems, offering advice, managing mildly to moderately severe cases, and referring more complicated cases to multidisciplinary teams. PMID:17279184
[Estimation of Maximum Entrance Skin Dose during Cerebral Angiography].
Kawauchi, Satoru; Moritake, Takashi; Hayakawa, Mikito; Hamada, Yusuke; Sakuma, Hideyuki; Yoda, Shogo; Satoh, Masayuki; Sun, Lue; Koguchi, Yasuhiro; Akahane, Keiichi; Chida, Koichi; Matsumaru, Yuji
2015-09-01
Using radio-photoluminescence glass dosimeter, we measured the entrance skin dose (ESD) in 46 cases and analyzed the correlations between maximum ESD and angiographic parameters [total fluoroscopic time (TFT); number of digital subtraction angiography (DSA) frames, air kerma at the interventional reference point (AK), and dose-area product (DAP)] to estimate the maximum ESD in real time. Mean (± standard deviation) maximum ESD, dose of the right lens, and dose of the left lens were 431.2 ± 135.8 mGy, 33.6 ± 15.5 mGy, and 58.5 ± 35.0 mGy, respectively. Correlation coefficients (r) between maximum ESD and TFT, number of DSA frames, AK, and DAP were r=0.379 (P<0.01), r=0.702 (P<0.001), r=0.825 (P<0.001), and r=0.709 (P<0.001), respectively. AK was identified as the most useful parameter for real-time prediction of maximum ESD. This study should contribute to the development of new diagnostic reference levels in our country.
Leder, Drew; Krucoff, Mitchell W
2011-09-01
Modern medicine is often accused by diverse critics of being "too materialistic" and therefore insufficiently holistic and effective. Yet, this critique can be misleading, dependent upon the ambiguous meanings of "materialism." The term can refer to the prevalence of financial concerns in driving medical practice. Alternatively, it can refer to "mechanistic materialism," the patient viewed as a body-machine. In each case, this article shows that this represents not authentic "materialism" at play, but a focus upon high-level abstractions. "Bottom-line" financial or diagnostic numbers can distract practitioners from the embodied needs of sick patients. In this sense, medical practice is not materialist enough. Through a series of clinical examples, this article explores how an authentic materialism would look in current and future practice. The article examines the use of prayer/comfort shawls at the bedside; hospitals and nursing homes redesigned as enriched healing environments; and a paradigmatic medical device--the implantable cardioverter defibrillator--as it might be presented to patients, in contrast to current practice.
Dueholm, Margit; Lundorf, Erik; Olesen, Frede
2002-06-01
A literature review compared the diagnostic effectiveness and accuracy of transvaginal sonography (TVS) hysterosonographic examination (HSE), hysteroscopy (HY), and magnetic resonance imaging (MRI) in abnormalities of the uterine cavity and endometrium in premenopausal patients referred to surgery and women with abnormal uterine bleeding. The studies varied much in terms of patient selection, number of observers, blinding and experience of observers, and definition of abnormality criteria. The diagnostic effectiveness of the techniques reviewed varied: TVS only reached intermediate quality levels as a diagnostic tool for exclusion of uterine cavity abnormalities and no data support that MRI, TVS, HY, or HSE may exclude hyperplasia without concomitant endometrial sampling. HY and HSE were equally effective and apparently outperformed TVS, especially for identification of polyps. However, all techniques carried a significant number of false positive results. MRI does not satisfy current diagnostic demands for detection of endometrial abnormalities, but it is sufficiently accurate for submucous myoma (SM) evaluation. TVS, HSE, and HY carry much observer variation as opposed to MRI. In experienced hands TVS should be a first choice modality, but its precision and consistency fall short of current needs and it should therefore be supplemented by other techniques. HSE or HY performed by experienced clinicians should be used as supplements to TVS for exclusion of polyps. MRI can be recommended as the first choice modality for exact evaluation of SM uterine in-growth before advanced minimal invasive treatment of myomas. Clinicians should be aware that modern imaging techniques may yield highly idiosyncratic results when used by inexperienced staff, and efforts should be made to reduce such observer variation. Obstetricians & Gynecologists, Family Physicians. After completion of this article, the reader will be able to describe the diagnostic strengths and weaknesses of the various diagnostic tests in the evaluation of abnormal uterine bleeding and to compare the accuracy of each test to the others.
A simple diagnostic model for ruling out pneumoconiosis among construction workers.
Suarthana, Eva; Moons, Karel G M; Heederik, Dick; Meijer, Evert
2007-09-01
Construction workers exposed to silica-containing dust are at risk of developing silicosis even at low exposure levels. Health surveillance among these workers is commonly advised but the exact diagnostic work-up is not specified and therefore may result in unnecessary chest x ray investigations. To develop a simple diagnostic model to estimate the probability of an individual worker having pneumoconiosis from questionnaire and spirometry results, in order to accurately rule out workers without pneumoconiosis. The study was performed using cross-sectional data of 1291 Dutch natural stone and construction workers with potentially high quartz dust exposure. A multivariable logistic regression model was developed using chest x ray with ILO profusion category > or =1/1 as the reference standard. The model's calibration was evaluated with the Hosmer-Lemeshow test; the discriminative ability was determined by calculating the area under the receiver operating characteristic curve (ROC area). Internal validity of the final model was assessed by a bootstrapping procedure. For clinical application, the diagnostic model was transformed into an easy-to-use score chart. Age 40 years or older, current smoker, high-exposure job, working 15 years or longer in the construction industry, "feeling unhealthy" and FEV1 were independent predictors in the diagnostic model. The model showed good calibration (a non-significant Hosmer-Lemeshow test) and discriminative ability (ROC area 0.81, 95% CI 0.74 to 0.85). Internal validity was reasonable; the optimism corrected ROC area was 0.76. By using a cut-off point with a high negative predictive value the occupational physician can efficiently detect a large proportion of workers with a low probability of having pneumoconiosis and exclude them from unnecessary x ray investigations. This diagnostic model is an efficient and effective instrument to rule out pneumoconiosis among construction workers. Its use in health surveillance among these workers can reduce the number of redundant x ray investigations.
Wasiewicz, Barbara
2016-01-01
The present article refers to the historical characterisation of Odo Bujwid's (1857-1942) research concerning the vaccine against rabies. The introduction refers to the treatment methods applied before Ludwik Pasteur's discovery. The following part refers to Odo Bujwid's own research including diagnostics, characterisation of the symptoms of disease, modification of the original Ludwik Pasteur's method and statistical information. The resume emphasizes that Odo Bujwid's scientific research was the introduction and generalisation the worldwide microbiology knowledge at the polish lands.
Genetics Home Reference: shingles
... Aftercare MedlinePlus Encyclopedia: Shingles National Health Service (UK): Post-Herpetic Neuralgia Treatment General Information from MedlinePlus (5 links) Diagnostic Tests Drug Therapy Genetic Counseling Palliative Care Surgery and ...
Helm, Caitlin E; Blackwood, R Alexander
2015-01-01
Pediatric autoimmune neuropsychiatric disorder associated with streptococcal infections (PANDAS) is an autoimmune disorder presenting with obsessive compulsive disorder and/or tics. Like Sydenham's chorea, its presumed pathogenesis consists of autoantibodies cross-reacting with neurons in response to a group A beta-hemolytic streptococcal infection (GASI). There are currently no diagnostic laboratory findings and management ranges from antibiotic prophylaxis to intravenous immunoglobulin to plasmapheresis. The diagnosis remains controversial, resulting in inconsistent referrals and significant patient anxiety. A retrospective study was performed on all patients referred to the Pediatric Infectious Disease Division with a pre-referral diagnosis of PANDAS. Patients were analyzed by demographics, medical history, co-morbidities, symptoms, prior treatment, laboratory tests, management strategies, and treatment outcomes. From 2003 to 2013, there were 21 patients with a pre-referral diagnosis of PANDAS. Only five met the diagnostic criteria. No patient at referral had an objective scale to monitor symptoms. Eight referrals had a major psychiatric disorder, and none fulfilled diagnostic criteria (p<0.01). The majority of the patients referred with a pre-diagnosis of PANDAS do not fulfill diagnostic criteria nor do they have objective criteria for symptom monitoring. Major psychiatric disorders do not seem to be associated with PANDAS, and better physician education may prevent misdiagnoses. Multidisciplinary management is recommended.
Imai, Kazuo; Tarumoto, Norihito; Misawa, Kazuhisa; Runtuwene, Lucky Ronald; Sakai, Jun; Hayashida, Kyoko; Eshita, Yuki; Maeda, Ryuichiro; Tuda, Josef; Murakami, Takashi; Maesaki, Shigefumi; Suzuki, Yutaka; Yamagishi, Junya; Maeda, Takuya
2017-09-13
A simple and accurate molecular diagnostic method for malaria is urgently needed due to the limitations of conventional microscopic examination. In this study, we demonstrate a new diagnostic procedure for human malaria using loop mediated isothermal amplification (LAMP) and the MinION™ nanopore sequencer. We generated specific LAMP primers targeting the 18S-rRNA gene of all five human Plasmodium species including two P. ovale subspecies (P. falciparum, P. vivax, P. ovale wallikeri, P. ovale curtisi, P. knowlesi and P. malariae) and examined human blood samples collected from 63 malaria patients in Indonesia. Additionally, we performed amplicon sequencing of our LAMP products using MinION™ nanopore sequencer to identify each Plasmodium species. Our LAMP method allowed amplification of all targeted 18S-rRNA genes of the reference plasmids with detection limits of 10-100 copies per reaction. Among the 63 clinical samples, 54 and 55 samples were positive by nested PCR and our LAMP method, respectively. Identification of the Plasmodium species by LAMP amplicon sequencing analysis using the MinION™ was consistent with the reference plasmid sequences and the results of nested PCR. Our diagnostic method combined with LAMP and MinION™ could become a simple and accurate tool for the identification of human Plasmodium species, even in resource-limited situations.
Williams, Emma L; Bagg, Eleanor A L; Mueller, Michael; Vandrovcova, Jana; Aitman, Timothy J; Rumsby, Gill
2015-01-01
Definitive diagnosis of primary hyperoxaluria (PH) currently utilizes sequential Sanger sequencing of the AGXT, GRPHR, and HOGA1 genes but efficacy is unproven. This analysis is time-consuming, relatively expensive, and delays in diagnosis and inappropriate treatment can occur if not pursued early in the diagnostic work-up. We reviewed testing outcomes of Sanger sequencing in 200 consecutive patient samples referred for analysis. In addition, the Illumina Truseq custom amplicon system was evaluated for paralleled next-generation sequencing (NGS) of AGXT,GRHPR, and HOGA1 in 90 known PH patients. AGXT sequencing was requested in all patients, permitting a diagnosis of PH1 in 50%. All remaining patients underwent targeted exon sequencing of GRHPR and HOGA1 with 8% diagnosed with PH2 and 8% with PH3. Complete sequencing of both GRHPR and HOGA1 was not requested in 25% of patients referred leaving their diagnosis in doubt. NGS analysis showed 98% agreement with Sanger sequencing and both approaches had 100% diagnostic specificity. Diagnostic sensitivity of Sanger sequencing was 98% and for NGS it was 97%. NGS has comparable diagnostic performance to Sanger sequencing for the diagnosis of PH and, if implemented, would screen for all forms of PH simultaneously ensuring prompt diagnosis at decreased cost. PMID:25629080
Non-invasive diagnostics of the maxillary and frontal sinuses based on diode laser gas spectroscopy.
Lewander, Märta; Lindberg, Sven; Svensson, Tomas; Siemund, Roger; Svanberg, Katarina; Svanberg, Sune
2012-03-01
Suspected, but objectively absent, rhinosinusitis constitutes a major cause of visits to the doctor, high health care costs, and the over-prescription of antibiotics, contributing to the serious problem of resistant bacteria. This situation is largely due to a lack of reliable and widely applicable diagnostic methods. A novel method for the diagnosis of rhinosinusitis based on non-intrusive diode laser gas spectroscopy is presented. The technique is based on light absorption by free gas (oxygen and water vapour) inside the sinuses, and has the potential to be a complementary diagnostic tool in primary health care. The method was evaluated on 40 patients with suspected sinus problems, referred to the diagnostic radiology clinic for low-dose computed tomography (CT), which was used as the reference technique. The data obtained with the new laser-based method correlated well with the grading of opacification and ventilation using CT. The sensitivity and specificity were estimated to be 93% and 61%, respectively, for the maxillary sinuses, and 94% and 86%, respectively, for the frontal sinuses. Good reproducibility was shown. The laser-based technique presents real-time clinical data that correlate well to CT findings, while being non-intrusive and avoiding the use of ionizing radiation.
[Circadian rhythm : Influence on Epworth Sleepiness Scale score].
Herzog, M; Bedorf, A; Rohrmeier, C; Kühnel, T; Herzog, B; Bremert, T; Plontke, S; Plößl, S
2017-02-01
The Epworth Sleepiness Scale (ESS) is frequently used to determine daytime sleepiness in patients with sleep-disordered breathing. It is still unclear whether different levels of alertness induced by the circadian rhythm influence ESS score. The aim of this study is to investigate the influence of circadian rhythm-dependent alertness on ESS performance. In a monocentric prospective noninterventional observation study, 97 patients with suspected sleep-disordered breathing were investigated with respect to daytime sleepiness in temporal relationship to polysomnographic examination and treatment. The Karolinska Sleepiness Scale (KSS) and the Stanford Sleepiness Scale (SSS) served as references for the detection of present sleepiness at three different measurement times (morning, noon, evening), prior to and following a diagnostic polysomnography night as well as after a continuous positive airway pressure (CPAP) titration night (9 measurements in total). The KSS, SSS, and ESS were performed at these times in a randomized order. The KSS and SSS scores revealed a circadian rhythm-dependent curve with increased sleepiness at noon and in the evening. Following a diagnostic polysomnography night, the scores were increased compared to the measurements prior to the night. After the CPAP titration night, sleepiness in the morning was reduced. KSS and SSS reflect the changes in alertness induced by the circadian rhythm. The ESS score war neither altered by the intra-daily nor by the inter-daily changes in the level of alertness. According to the present data, the ESS serves as a reliable instrument to detect the level of daytime sleepiness independently of the circadian rhythm-dependent level of alertness.
Tunç, Abdulkadir; Güngen, Belma Doğan
2017-01-01
Electro-diagnostic studies are the most reliable methods in diagnosis of carpal tunnel syndrome (CTS). Although there are many risk factors associated with CTS, there are a limited number of studies in the literature indicating that manual milking, which is frequently seen in Turkey, is a risk factor for CTS. The purpose of this study was to evaluate demographic findings of cases referred due to initial diagnosis of CTS as well as aetiological data especially manual milking and to investigate the sensitivity of initial diagnosis of CTS. Six hundred patients, who were referred to our electromyography laboratory due to initial diagnosis of CTS, were included. Demographic findings, duration of complaints, existence of diabetes mellitus, and manual milking histories of all patients were recorded. Sensitivity of initial diagnosis was investigated based on electro-diagnostic test results. According to electro-diagnostic test results, 289 of the patients were diagnosed with CTS (48.17%). 110 (18.3%) of 600 patients had a history of manual milking. In 94 of this group (85.4%), CTS was detected. Statistically significant correlation was found between CTS and age, female gender, duration of complaints, obesity and manual milking. This study confirms that manual milking is an important risk factor for CTS in addition to female gender, age, symptom duration and obesity. The fact that sensitivity of initial diagnosis of CTS was found to be low according to electro-diagnostic test results indicates importance of detailed clinical evaluation.
Lidbury, Brett A; Kita, Badia; Lewis, Donald P; Hayward, Susan; Ludlow, Helen; Hedger, Mark P; de Kretser, David M
2017-03-16
Investigations of activin family proteins as serum biomarkers for chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME). CFS/ME is a disease with complex, wide-ranging symptoms, featuring persistent fatigue of 6 months or longer, particularly post exertion. No definitive biomarkers are available. A cross-sectional, observational study of CFS/ME patients fulfilling the 2003 Canadian Consensus Criteria, in parallel with healthy non-fatigued controls, was conducted. Comparisons with a previously defined activin reference population were also performed. For the total study cohort the age range was 18-65 years with a female: male participant ratio of greater than 3:1. All participants were assessed via a primary care community clinic. Blood samples were collected for pathology testing after physical examination and orthostatic intolerance assessment. Cytokines, activin A, activin B and follistatin were also measured in sera from these samples. All data were compared between the CFS/ME and control cohorts, with the activins and follistatin also compared with previously defined reference intervals. Serum activin B levels for CFS/ME participants were significantly elevated when compared to the study controls, as well as the established reference interval. Serum activin A and follistatin were within their normal ranges. All routine and special pathology markers were within the normal laboratory reference intervals for the total study cohort, with no significant differences detected between CFS/ME and control groups. Also, no significant differences were detected for IL-2, IL-4, IL-6, IL-10, IL-17A, TNF or IFN-gamma. Elevated activin B levels together with normal activin A levels identified patients with the diagnostic symptoms of CFS/ME, thus providing a novel serum based test. The activins have multiple physiological roles and capture the diverse array of symptoms experienced by CFS/ME patients.
Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji
2013-08-01
To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.
Mamtani, Manju; Jawahirani, Anil; Das, Kishor; Rughwani, Vinky; Kulkarni, Hemant
2006-08-01
It is being increasingly recognized that a majority of the countries in the thalassemia-belt need a cost-effective screening program as the first step towards control of thalassemia. Although the naked eye single tube red cell osmotic fragility test (NESTROFT) has been considered to be a very effective screening tool for beta-thalassemia trait, assessment of its diagnostic performance has been affected with the reference test- and verification-bias. Here, we set out to provide estimates of sensitivity and specificity of NESTROFT corrected for these potential biases. We conducted a cross-sectional diagnostic test evaluation study using data from 1563 subjects from Central India with a high prevalence of beta-thalassemia. We used latent class modelling after ensuring its validity to account for the reference test bias and global sensitivity analysis to control the verification bias. We also compared the results of latent class modelling with those of five discriminant indexes. We observed that across a range of cut-offs for the mean corpuscular volume (MCV) and the hemoglobin A2 (HbA2) concentration the average sensitivity and specificity of NESTROFT obtained from latent class modelling was 99.8 and 83.7%, respectively. These estimates were comparable to those characterizing the diagnostic performance of HbA2, which is considered by many as the reference test to detect beta-thalassemia. After correction for the verification bias these estimates were 93.4 and 97.2%, respectively. Combined with the inexpensive and quick disposition of NESTROFT, these results strongly support its candidature as a screening tool-especially in the resource-poor and high-prevalence settings.
Stavri, Henriette; Bucurenci, Nadia; Ulea, Irina; Costache, Adriana; Popa, Loredana; Popa, Mircea Ioan
2012-11-01
Purified protein derivative (PPD) is currently the only available skin test reagent used worldwide for the diagnosis of tuberculosis (TB). The aim of this study was to develop a Mycobacterium tuberculosis specific skin test reagent, without false positive results due to Bacillus Calmette-Guerin (BCG) vaccination using recombinant antigens. Proteins in PPD IC-65 were analyzed by tandem mass spectrometry and compared to proteins in M. tuberculosis culture filtrate; 54 proteins were found in common. Top candidates MPT64, ESAT 6, and CFP 10 were overexpressed in Escherichia coli expression strains and purified as recombinant proteins. To formulate optimal immunodiagnostic PPD cocktails, the antigens were evaluated by skin testing guinea pigs sensitized with M. tuberculosis H37Rv and BCG. For single antigens and a cocktail mixture of these antigens, best results were obtained using 3 μg/0.1 ml, equivalent to 105 TU (tuberculin units). Each animal was simultaneously tested with PPD IC-65, 2 TU/0.1 ml, as reference. Reactivity of the multi-antigen cocktail was greater than that of any single antigen. The skin test results were between 34.3 and 76.6 per cent the level of reactivity compared to that of the reference when single antigens were tested and 124 per cent the level of reactivity compared to the reference for the multi-antigen cocktail. Our results showed that this specific cocktail could represent a potential candidate for a new skin diagnostic test for TB.
Yan, Qun; Karau, Melissa J; Greenwood-Quaintance, Kerryl E; Mandrekar, Jayawant N; Osmon, Douglas R; Abdel, Matthew P; Patel, Robin
2018-06-01
We have previously demonstrated that culturing periprosthetic tissue in blood culture bottles (BCBs) improves sensitivity compared to conventional agar and broth culture methods for diagnosis of prosthetic joint infection (PJI). We have also shown that prosthesis sonication culture improves sensitivity compared to periprosthetic tissue culture using conventional agar and broth methods. The purpose of this study was to compare the diagnostic accuracy of tissue culture in BCBs (subsequently referred to as tissue culture) to prosthesis sonication culture (subsequently referred to as sonicate fluid culture). We studied 229 subjects who underwent arthroplasty revision or resection surgery between March 2016 and October 2017 at Mayo Clinic in Rochester, Minnesota. Using the Infectious Diseases Society of America (IDSA) PJI diagnostic criteria (omitting culture criteria) as the gold standard, the sensitivity of tissue culture was similar to that of the sonicate fluid culture (66.4% versus 73.1%, P = 0.07) but was significantly lower than that of the two tests combined (66.4% versus 76.9%, P < 0.001). Using Bayesian latent class modeling, which assumes no gold standard for PJI diagnosis, the sensitivity of tissue culture was slightly lower than that of sonicate fluid culture (86.3% versus 88.7%) and much lower than that of the two tests combined (86.3% versus 99.1%). In conclusion, tissue culture in BCBs reached sensitivity similar to that of prosthesis sonicate fluid culture for diagnosis of PJI, but the two tests combined had the highest sensitivity without compromising specificity. The combination of tissue culture in BCBs and sonicate fluid culture is recommended to achieve the highest level of microbiological diagnosis of PJI. Copyright © 2018 American Society for Microbiology.
2013-01-01
Background There have been few investigations evaluating the burden of malaria disease at district level in the Republic of Congo since the introduction of artemisinin-based combination therapies (ACTs). The main objective of this study was to document laboratory-confirmed cases of malaria using microscopy and/or rapid diagnostic tests (RDTs) in children and pregnant women attending selected health facilities in Brazzaville and Pointe Noire, the two main cities of the country. Secondly, P. falciparum genetic diversity and multiplicity of infection during the malaria transmission season of October 2011 to February 2012 in these areas were described. Methods Three and one health facilities were selected in Brazzaville and Pointe-Noire as sentinel sites for malaria surveillance. Children under 15 years of age and pregnant women were enrolled if study criteria were met and lab technicians used RDT and/or microscopy to diagnose malaria. In order to determine the multiplicity of infection, parasite DNA was extracted from RDT cassette and msp2 P.falciparum genotyped. Results Malaria prevalence among more than 3,000 children and 700 pregnant women ranged from 8 to 29%, and 8 to 24% respectively depending on health center locality. While health workers did not optimize use of RDTs, microscopy remained a reference diagnostic tool. Quality control of malaria diagnosis at the reference laboratory showed acceptable health centre performances. P. falciparum genetic diversity determination using msp2 gene marker ranged from 9 to 20 alleles and remains stable while multiplicity of infection (mean of 1.7clone/infected individual) and parasite densities in clinical isolates were lower than previously reported. Conclusions These findings are consistent with a reduction of malaria transmission in the two areas. This study raises the issue of targeted training for health workers and sustained availability of RDTs in order to improve quality of care through optimal use of RDTs. PMID:23409963
ERIC Educational Resources Information Center
Zimmermann, Friederike; Möller, Jens; Köller, Olaf
2018-01-01
The internal/external frame of reference model (I/E model) posits that individuals' achievement-related self-concepts are formed through social comparisons (e.g., self vs. peers) within academic domains and dimensional comparisons (e.g., math vs. verbal) between distinct domains. A large body of research has supported the theorized pattern of…
ERIC Educational Resources Information Center
Shambaugh, Evelyn M., Ed.
Book 3 of the self-instructional manual for tumor registrars deals with tumor registrar vocabulary. It is designed to teach tumor registrars to recognize diagnostic terms versus treatment terms, terms that refer to anatomical sites, terms that refer to patient symptoms. The first three parts of the book are concerned with word roots, prefixes and…
Bottom-up or top-down: unit cost estimation of tuberculosis diagnostic tests in India.
Rupert, S; Vassall, A; Raizada, N; Khaparde, S D; Boehme, C; Salhotra, V S; Sachdeva, K S; Nair, S A; Hoog, A H Van't
2017-04-01
Of 18 sites that participated in an implementation study of the Xpert® MTB/RIF assay in India, we selected five microscopy centres and two reference laboratories. To obtain unit costs of diagnostic tests for tuberculosis (TB) and drug-resistant TB. Laboratories were purposely selected to capture regional variations and different laboratory types. Both bottom-up and the top-down methods were used to estimate unit costs. At the microscopy centres, mean bottom-up unit costs were respectively US$0.83 (range US$0.60-US$1.10) and US$12.29 (US$11.61-US$12.89) for sputum smear microscopy and Xpert. At the reference laboratories, mean unit costs were US$1.69 for the decontamination procedure, US$9.83 for a solid culture, US$11.06 for a liquid culture, US$29.88 for a drug susceptibility test, and US$18.18 for a line-probe assay. Top-down mean unit cost estimates were higher for all tests, and for sputum smear microscopy and Xpert these increased to respectively US$1.51 and US$13.58. The difference between bottom-up and top-down estimates was greatest for tests performed at the reference laboratories. These unit costs for TB diagnostics can be used to estimate resource requirements and cost-effectiveness in India, taking into account geographical location, laboratory type and capacity utilisation.
The importance of semen analysis in the context of azoospermia.
Aziz, Nabil
2013-01-01
Azoospermia is a descriptive term referring to ejaculates that lack spermatozoa without implying a specific underlying cause. The traditional definition of azoospermia is ambiguous, which has ramifications on the diagnostic criteria. This issue is further compounded by the apparent overlap between the definitions of oligospermia and azoospermia. The reliable diagnosis of the absence of spermatozoa in a semen sample is an important criterion not only for diagnosing male infertility but also for ascertaining the success of a vasectomy and for determining the efficacy of hormonal contraception. There appears to be different levels of rigor in diagnosing azoospermia in different clinical situations, which highlights the conflict between scientific research and clinical practice in defining azoospermia.
Healing and transculturation in Xhosa Zionist practice.
Edwards, F S
1983-06-01
The process of transculturation of healing is considered in the cultural belief system and practice of a Xhosa Zionist community. At present in the throes of rapid socio-cultural transition, this community operates with a holistic understanding of health and sickness in which all levels of existence, including the superempirical, are held to be in dynamic mutual interrelationship. The paper examines categories of illness, diagnostic procedures and therapeutic practices in relation to converging traditional Xhosa and Western Christian frames of reference and two illustrative case histories are presented. The use made of heightening of individual and group consciousness is briefly assessed. The Zionist belief system and therapeutic practices are evaluated in terms of cultural accessibility and sociopolitical influences.
Akaba, Tomohiro; Takeyama, Kiyoshi; Toriyama, Midori; Kubo, Ayako; Mizobuchi, Rie; Yamada, Takeshi; Tagaya, Etsuko; Kondo, Mitsuko; Sakai, Shuji; Tamaoki, Jun
2016-01-01
A 38-year-old woman with sustained right chest pain was referred to our hospital. She showed pleural effusion and peripheral blood eosinophilia. Thoracentesis revealed eosinophilic pleural effusion in which the smear, culture and cytological examinations were all negative. Although she had no notable dietary history, chest CT revealed linear opacities, which suggested the migration tracks of paragonimiasis. The diagnosis was confirmed using enzyme-linked immunosorbent assays, which showed elevated Paragonimus westermani and Paragonimus miyazakii antibody levels. After the initiation of praziquantel therapy, all clinical findings were promptly improved. The detection of a migration track may therefore be useful in the diagnosis of paragonimiasis.
[Construction of educational software about personality disorders].
Botti, Nadja Cristiane Lappann; Carneiro, Ana Luíza Marques; Almeida, Camila Souza; Pereira, Cíntia Braga Silva
2011-01-01
The study describes the experience of building educational software in the area of mental health. The software was developed to enable the nursing student identify personality disorders. In this process, we applied the pedagogical framework of Vygotsky and the theoretical framework of the diagnostic criteria defined by DSM-IV. From these references were identified personality disorders characters in stories and / or children's movies. The software development bank was built with multimedia graphics data, sound and explanatory. The software developed like educational game like questions with increasing levels of difficulty. The software was developed with Microsoft Office PowerPoint 2007. It is believed in the validity of this strategy for teaching-learning to the area of mental health nursing.
Genetics Home Reference: blepharocheilodontic syndrome
... Palate American Association of Oral and Maxillofacial Surgeons: Cleft Lip/Palate and Craniofacial Surgery MedlinePlus Encyclopedia: Cleft Lip and Palate Repair General Information from MedlinePlus (5 links) Diagnostic ...
... of the pleura Images Pleural biopsy References Klein JS, Bhave AD. Thoracic radiology: invasive diagnostic imaging and image-guided interventions. In: Broaddus VC, Mason RJ, Ernst JD, et al, eds. Murray and ...
Aprahamian, Ivan; Martinelli, José Eduardo; Cecato, Juliana; Izbicki, Rafael; Yassuda, Mônica Sanches
2011-02-01
The Cambridge Cognitive Examination (CAMCOG) is a useful test in screening for Alzheimer's disease (AD). However, the interpretation of CAMCOG cut-off scores is problematic and reference values are needed for different educational strata. Given the importance of earlier diagnoses of mild dementia, new cut-off values are required which take into account patients with low levels of education. This study aims to evaluate whether the CAMCOG can be used as an accurate screening test among AD patients and normal controls with different educational levels. Cross-sectional assessment was undertaken of 113 AD and 208 elderly controls with heterogeneous educational levels (group 1: 1-4 years; group 2: 5-8 years; and group 3: ≥ 9 years) from a geriatric clinic. submitted to a thorough diagnostic evaluation for AD including the Cambridge Examination for Mental Disorders of the Elderly (CAMDEX). Controls had no cognitive or mood complaints. Sensitivity (SE) and specificity (SP) for the CAMCOG in each educational group was assessed with receiver-operator-characteristic (ROC) curves. CAMCOG mean values were lower when education was reduced in both diagnostic groups (controls - group 1: 87; group 2: 91; group 3: 96; AD - group 1: 63; group 2: 62; group 3: 77). Cut-off scores for the three education groups were 79, 80 and 90, respectively. SE and SP varied among the groups (group 1: 88.1% and 83.5%; group 2: 84.6% and 96%; group 3: 70.8% and 90%). The CAMCOG can be used as a cognitive test for patients with low educational level with good accuracy. Patients with higher education showed lower scores than previously reported.
Simmonds, H A; Fairbanks, L D; Morris, G S; Webster, D R; Harley, E H
1988-02-15
This paper compares erythrocyte nucleotide levels in patients with eight different inherited purine or pyrimidine enzyme defects identified amongst a variety of patients referred predominantly for investigation of severe neurological abnormalities, or immunodeficiency syndromes. Characteristic nucleotide patterns were identified only in the six disorders (four involving purine and two pyrimidine metabolism) where there was clinical evidence of cellular toxicity. They were frequently related to the accumulation of abnormal metabolites in body fluids. These erythrocyte studies have demonstrated the following. 1. ATP depletion is not an invariable feature of adenosine deaminase (ADA) deficiency, but the accumulation of the deoxyribonucleotides dATP, or dGTP, is diagnostic of ADA, or purine nucleoside phosphorylase (PNP) deficiency, respectively. The early accumulation of dATP in foetal blood is a valuable aid to prenatal diagnosis of ADA deficiency. 2. GTP depletion appears to reflect the degree of CNS involvement in hypoxanthine-guanine phosphoribosyltransferase and PNP deficiency, as well as PP-ribose-P synthetase superactivity. Other diagnostic changes involving increased pyrimidine sugars and increased or decreased NAD levels, or ZTP in Lesch Nyhan erythrocytes, show no consistent correlation with the clinical manifestations. 3. These altered nucleotide levels afford a novel means for carrier detection of the X-linked defect associated with aberrant PP-ribose-P synthetase activity, where no other test is yet available. Measurement of erythrocyte nucleotide levels thus provides a simple and rapid aid to diagnosis and may sometimes be essential for determining prognosis, carrier detection, or monitoring therapy. These characteristic 'fingerprints' may give some insight into the mechanism by which the abnormal gene product produces disease. Such grossly altered nucleotide levels could also result in loss of erythrocyte flexibility, increased destruction and hence the anaemia, or other clinical manifestations, observed in some disorders.
Saini, V.; Riekerink, R. G. M. Olde; McClure, J. T.; Barkema, H. W.
2011-01-01
Determining the accuracy and precision of a measuring instrument is pertinent in antimicrobial susceptibility testing. This study was conducted to predict the diagnostic accuracy of the Sensititre MIC mastitis panel (Sensititre) and agar disk diffusion (ADD) method with reference to the manual broth microdilution test method for antimicrobial resistance profiling of Escherichia coli (n = 156), Staphylococcus aureus (n = 154), streptococcal (n = 116), and enterococcal (n = 31) bovine clinical mastitis isolates. The activities of ampicillin, ceftiofur, cephalothin, erythromycin, oxacillin, penicillin, the penicillin-novobiocin combination, pirlimycin, and tetracycline were tested against the isolates. Diagnostic accuracy was determined by estimating the area under the receiver operating characteristic curve; intertest essential and categorical agreements were determined as well. Sensititre and the ADD method demonstrated moderate to highly accurate (71 to 99%) and moderate to perfect (71 to 100%) predictive accuracies for 74 and 76% of the isolate-antimicrobial MIC combinations, respectively. However, the diagnostic accuracy was low for S. aureus-ceftiofur/oxacillin combinations and other streptococcus-ampicillin combinations by either testing method. Essential agreement between Sensititre automatic MIC readings and MIC readings obtained by the broth microdilution test method was 87%. Essential agreement between Sensititre automatic and manual MIC reading methods was 97%. Furthermore, the ADD test method and Sensititre MIC method exhibited 92 and 91% categorical agreement (sensitive, intermediate, resistant) of results, respectively, compared with the reference method. However, both methods demonstrated lower agreement for E. coli-ampicillin/cephalothin combinations than for Gram-positive isolates. In conclusion, the Sensititre and ADD methods had moderate to high diagnostic accuracy and very good essential and categorical agreement for most udder pathogen-antimicrobial combinations and can be readily employed in veterinary diagnostic laboratories. PMID:21270215
Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing
2016-01-01
A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method. PMID:26761006
Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing
2016-01-08
A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method.
Realtime Knowledge Management (RKM): From an International Space Station (ISS) Point of View
NASA Technical Reports Server (NTRS)
Robinson, Peter I.; McDermott, William; Alena, Richard L.
2004-01-01
We are developing automated methods to provide realtime access to spacecraft domain knowledge relevant a spacecraft's current operational state. The method is based upon analyzing state-transition signatures in the telemetry stream. A key insight is that documentation relevant to a specific failure mode or operational state is related to the structure and function of spacecraft systems. This means that diagnostic dependency and state models can provide a roadmap for effective documentation navigation and presentation. Diagnostic models consume the telemetry and derive a high-level state description of the spacecraft. Each potential spacecraft state description is matched against the predictions of models that were developed from information found in the pages and sections in the relevant International Space Station (ISS) documentation and reference materials. By annotating each model fragment with the domain knowledge sources from which it was derived we can develop a system that automatically selects those documents representing the domain knowledge encapsulated by the models that compute the current spacecraft state. In this manner, when the spacecraft state changes, the relevant documentation context and presentation will also change.
Knuuti, Juhani; Ballo, Haitham; Juarez-Orozco, Luis Eduardo; Saraste, Antti; Kolh, Philippe; Rutjes, Anne Wilhelmina Saskia; Jüni, Peter; Windecker, Stephan; Bax, Jeroen J; Wijns, William
2018-05-29
To determine the ranges of pre-test probability (PTP) of coronary artery disease (CAD) in which stress electrocardiogram (ECG), stress echocardiography, coronary computed tomography angiography (CCTA), single-photon emission computed tomography (SPECT), positron emission tomography (PET), and cardiac magnetic resonance (CMR) can reclassify patients into a post-test probability that defines (>85%) or excludes (<15%) anatomically (defined by visual evaluation of invasive coronary angiography [ICA]) and functionally (defined by a fractional flow reserve [FFR] ≤0.8) significant CAD. A broad search in electronic databases until August 2017 was performed. Studies on the aforementioned techniques in >100 patients with stable CAD that utilized either ICA or ICA with FFR measurement as reference, were included. Study-level data was pooled using a hierarchical bivariate random-effects model and likelihood ratios were obtained for each technique. The PTP ranges for each technique to rule-in or rule-out significant CAD were defined. A total of 28 664 patients from 132 studies that used ICA as reference and 4131 from 23 studies using FFR, were analysed. Stress ECG can rule-in and rule-out anatomically significant CAD only when PTP is ≥80% (76-83) and ≤19% (15-25), respectively. Coronary computed tomography angiography is able to rule-in anatomic CAD at a PTP ≥58% (45-70) and rule-out at a PTP ≤80% (65-94). The corresponding PTP values for functionally significant CAD were ≥75% (67-83) and ≤57% (40-72) for CCTA, and ≥71% (59-81) and ≤27 (24-31) for ICA, demonstrating poorer performance of anatomic imaging against FFR. In contrast, functional imaging techniques (PET, stress CMR, and SPECT) are able to rule-in functionally significant CAD when PTP is ≥46-59% and rule-out when PTP is ≤34-57%. The various diagnostic modalities have different optimal performance ranges for the detection of anatomically and functionally significant CAD. Stress ECG appears to have very limited diagnostic power. The selection of a diagnostic technique for any given patient to rule-in or rule-out CAD should be based on the optimal PTP range for each test and on the assumed reference standard.
Namatovu, Alice; Wekesa, Sabenzia Nabalayo; Tjørnehøj, Kirsten; Dhikusooka, Moses Tefula; Muwanika, Vincent B; Siegsmund, Hans Redlef; Ayebazibwe, Chrisostom
2013-01-24
Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006-2010. The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples.
2013-01-01
Background Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006–2010. Results The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. Conclusions This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples. PMID:23347795
Evaluation of acoustic Doppler velocimetry (ADV) performance under various probe configurations
NASA Astrophysics Data System (ADS)
Liu, Da; Valyrakis, Manousos
2017-04-01
Acoustic Doppler velocimetry (ADV) is widely used as one of the most versatile and robust flow diagnostics tools for both laboratory and field studies across a range of research and applied themes spanning engineering eco-hydraulics and geomorphology. A range of specific ADV probes with varying specifications, are readily available for use by professionals and researchers. However, in practice using certain ADV equipment under certain default configurations can easily result in obtaining flow diagnostics that are non-representative of the real flow conditions. This appears to be true for most probes but even more those with which higher temporal resolution can be achieved - which many times is desired for assessing turbulence levels, amongst others. A preliminary examination revealed that there is a varying level of dependency on a number of the probes' configuration parameters, which even though detailed in the user manual, a definite guide for the user is lacking. Subsequently users of this equipment may end up underutilizing or using it in a manner that returns inaccurate results. There are little, if any, resources in obtaining a better understanding on how to use the probe effectively. To this goal a series of laboratory experiments are conducted, under the same open channel flow conditions, using a profiler (ADCP VectrinoII from Nortek®) aiming to cover the full range of probe configuration combinations that can be used in practice. For each experiment, single or multiple point measurements are taken to reconstruct velocity and turbulence intensity profiles. These are conducted at the same location (mid-channel) under the same flow conditions (referring to steady uniform flow and fully developed turbulence) for all probe configurations. In particular, the effect of tested parameters (including Range length, Range to fist cell, Sampling rate, Ping algorithm, Transmit pulse size and Cell size) on the sensitivity and accuracy of the obtained results is assessed. The signal to noise ratio (SNR) and the correlation of the measurement are used in evaluating the data quality, while a qualitative comparison of the resulting profiles for flow diagnostics is enabled using reference profiles obtained via a VectrinoI ADV (from Nortek®) and MicroADV (from Sontek®) respectively under the exactly same flow condition at the same location. These observations are important to identify its best configuration for a given probe towards improving the data quality and accuracy.
Diagnostic accuracy of Xpert MTB/RIF assay for musculoskeletal tuberculosis: a meta-analysis.
Wen, Hai; Li, Pengzhi; Ma, Hong; Lv, Guohua
2017-01-01
Xpert MTB/RIF assay, a rapid and automated real-time nucleic acid amplification test, has been reported for the diagnosis of musculoskeletal tuberculosis (TB) in current years. This meta-analysis aims to determine the diagnostic accuracy of Xpert for the detection of musculoskeletal TB and rifampicin (RIF) resistance. We searched PubMed, Embase, China National Knowledge Infrastructure, and Wanfang for original articles published up to 1st June 2017 to identify studies in which the Xpert assay was applied to diagnose musculoskeletal TB. Pooled estimates were calculated using a random-effects model or a fixed-effects model according to heterogeneity. Summary receiver operating characteristic curves and the area under the curve (AUC) were used to summarize overall diagnostic performance. Deeks' test was performed to evaluate potential publication bias. Twelve studies were identified with a pooled sensitivity and specificity of respectively 0.81 (95% confidence interval [CI] 0.78-0.83) and 0.83 (95% CI 0.80-0.86) of Xpert for the diagnosis of musculoskeletal TB. Xpert was highly sensitive (0.89, 95% CI 0.79-0.95) and highly specific (0.96, 95% CI 0.92-0.98) in detecting RIF resistance. AUC (over 0.9) suggested a relatively high level of overall diagnostic accuracy of Xpert for detecting musculoskeletal TB and RIF resistance. Prevalence and reference standard were indicated to be sources of heterogeneity between studies. No publication bias was found. This study provides available evidence of the rapid and effective role of Xpert in diagnosing musculoskeletal TB and detecting RIF resistance.
Influence of skin colour on diagnostic accuracy of the jaundice meter JM 103 in newborns.
Samiee-Zafarghandy, S; Feberova, J; Williams, K; Yasseen, A S; Perkins, S L; Lemyre, B
2014-11-01
To assess the diagnostic accuracy of the JM 103 as a screening tool for neonatal jaundice and explore differential effects based on skin colour. We prospectively compared the transcutaneous bilirubin (TcB) and serum bilirubin (TSB) measurements of newborns over a 3 month-period. Skin colour was assigned via reference colour swatches. Diagnostic measures of the TcB/TSB comparison were made and clinically relevant TcB cut-off values were determined for each skin colour group. 451 infants (51 light, 326 medium and 74 dark skin colour) were recruited. The association between TcB and TSB was high for all skin colours (rs>0.9). The Bland-Altman analysis showed an absolute mean difference between the two measures of 13.3±26.4 µmol/L with broad limits of agreement (-39.4-66.0 µmol/L), with TcB underestimating TSB in light and medium skin colours and overestimating in dark skin colour. Diagnostic measures were also consistently high across skin colours, with no clinically significant differences observed. The JM 103 is a useful screening tool to identify infants in need of serum bilirubin, regardless of skin colour. The effect of skin colour on the accuracy of this device at high levels of serum bilirubin could not be assessed fully due to small numbers in the light and dark groups. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
[A boy with a painful knee: bone tumour or stress fracture?].
Robben, Bart J; Jutte, Paul C
2012-01-01
The symptoms of a stress fracture are almost identical to those of most bone tumours. Even with the use of various imaging techniques, it can be difficult to establish the correct diagnosis. Although a primary bone tumour requires early treatment to improve its prognosis, the discriminative factor in the diagnosis of a stress fracture is its clinical development over time. A 10-year-old boy was referred to our outpatient clinic on the suspicion of a primary bone tumour in his right tibia. A case was once described in this journal in which a stress fracture had eventually led to an amputation. The suspicion of primary bone tumour often marks the start of a long and intense diagnostic course. A stress fracture is the major diagnostic pitfall when there is a suspicion of such a tumour. If doubts persist after a diagnostic work-up by imaging, consultation with the Bone Tumour Committee is indicated. The patient can also be quickly referred to a centre specialised in treating bone tumours, as was the case in this article.
Zanella, Gloria; Pullini, Serena; Como, Giuseppe; Bazzocchi, Massimo
2014-01-01
Purpose. To quantify the impact of diagnostic confidence on radiological diagnosis with a fuzzy logic-based method. Materials and Methods. Twenty-two oncologic patients with 20 cysts and 30 metastases ≤1 cm in size found at 64-row computed tomography were included. Two readers (R1/R2) expressed diagnoses as a subjective level of confidence P(d) in malignancy within the interval [0,1] rather than on a “crisp” basis (malignant/benign); confidence in benignancy was 1 − p(d). When cross-tabulating data according to the standard of reference, 2 × 2 table cells resulted from the aggregation between p(d)/1 − p(d) and final diagnosis. We then assessed (i) readers diagnostic performance on a fuzzy and crisp basis; (ii) the “divergence” δ(F, C) (%) as a measure of how confidence impacted on crisp diagnosis. Results. Diagnoses expressed with lower confidence increased fuzzy false positives compared to crisp ones (from 0 to 0.2 for R1; from 1 to 2.4 for R2). Crisp/fuzzy accuracy was 94.0%/93.6% (R1) and 94.0/91.6% (R2). δ(F, C) (%) was larger in the case of the less experienced reader (R2) (up to +7.95% for specificity). According to simulations, δ(F, C) (%) was negative/positive depending on the level of confidence in incorrect diagnoses. Conclusion. Fuzzy evaluation shows a measurable effect of uncertainty on radiological diagnoses. PMID:24587815
Prevalence of temporomandibular disorders in patients with Hashimoto thyroiditis.
Grozdinska, Alina; Hofmann, Elisabeth; Schmid, Matthias; Hirschfelder, Ursula
2018-05-17
Autoimmune thyroid disease (AITD), also known as Hashimoto thyroiditis (HT), is a degenerative inflammatory disease with high prevalence among women and has been associated with fibromyalgia and widespread chronic pain. The goal was to determine the frequency of temporomandibular disorders (TMD) in patients with HT. In all, 119 women (age 19-60 years) were divided into a study (52 women diagnosed with HT) and a control (67 healthy individuals, of which 15 were excluded) group. Serum concentrations of thyroid-stimulating hormone (TSH), free triiodothyronine (fT3), free thyroxine (fT4), anti-thyroglobulin (Tg) and anti-thyroid peroxidase (TPO) antibody levels were measured. The temporomandibular jaw and muscles were examined using the German Society of Functional Diagnostics and Therapy guidelines. The Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) was used to assess TMD. Standardized questionnaires, incorporating epidemiological criteria, state and treatment of the thyroid disease, Helkimo Index (HI), and Fonseca Anamnestic Index (FAI), were filled out by all patients. The two groups did not differ in terms of demographic parameters or mandibular jaw mobility. Significantly higher levels of anti-TPO and anti-Tg were attested in all subjects of the HT group. Markedly elevated prevalence of TMD was found in the HT group. Muscle pain and stiffness were found in 45 (86.5%) subjects of the HT group (p < 0.001), of whom 33 (63.4%) also had disc displacement with reposition (p < 0.001). Whereas 50% of the control group showed no TMD symptoms, all subjects in the HT group had symptoms. A significantly elevated prevalence of TMD was found in patients with HT. Thus, patients with TMD who do not respond to therapy should be referred for thyroid diagnostic workup.
Hamed, Maged Abdel Galil; Basha, Mohammad Abd Alkhalik; Ahmed, Hussien; Obaya, Ahmed Ali; Afifi, Amira Hamed Mohamed; Abdelbary, Eman H
2018-06-20
68 Ga-prostate-specific membrane antigen-11 ( 68 Ga-PSMA-11) is a recently developed positron emission tomography (PET) tracer that can detect prostate cancer (PC) relapses and metastases with high contrast resolution. The aim of this study was to assess the detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT image in patients with rising prostatic-specific antigen (PSA) after treatment of PC. The present prospective study included 188 patients who exhibited rising of PSA level on a routine follow-up examination after definitive treatment of PC. All patients underwent a 68 Ga-PSMA PET/CT examination. For each patient, we determined the disease stage, the Gleason score, and the maximum standardized uptake value of the local recurrence and extraprostatic metastases. The detection efficacy and diagnostic accuracy of 68 Ga-PSMA PET/CT were established by histopathology and clinical and imaging follow-up as the reference standards. 68 Ga-PSMA PET/CT detected tumour relapse in 165 patients (35 patients had local recurrence, 106 patients had extraprostatic metastases, and 24 patients had combined lesions). The sensitivity, specificity, and accuracy values of 68 Ga-PSMA PET/CT examination in the detection of PC recurrence were 98.8%, 100%, and 98.8%, respectively. 68 Ga-PSMA PET/CT revealed an overall detection rate of 87.8% (165/188) in patients with rising PSA (median of 2.2 ng/mL, and range of 0.01-70 ng/mL). 68 Ga-PSMA PET/CT is a valuable tool for the detection of PC local recurrence or extraprostatic metastases following rising PSA levels after primary definitive therapy and should be incorporated during routine work-up. Copyright © 2018. Published by Elsevier Inc.
Hybrid Kalman Filter: A New Approach for Aircraft Engine In-Flight Diagnostics
NASA Technical Reports Server (NTRS)
Kobayashi, Takahisa; Simon, Donald L.
2006-01-01
In this paper, a uniquely structured Kalman filter is developed for its application to in-flight diagnostics of aircraft gas turbine engines. The Kalman filter is a hybrid of a nonlinear on-board engine model (OBEM) and piecewise linear models. The utilization of the nonlinear OBEM allows the reference health baseline of the in-flight diagnostic system to be updated to the degraded health condition of the engines through a relatively simple process. Through this health baseline update, the effectiveness of the in-flight diagnostic algorithm can be maintained as the health of the engine degrades over time. Another significant aspect of the hybrid Kalman filter methodology is its capability to take advantage of conventional linear and nonlinear Kalman filter approaches. Based on the hybrid Kalman filter, an in-flight fault detection system is developed, and its diagnostic capability is evaluated in a simulation environment. Through the evaluation, the suitability of the hybrid Kalman filter technique for aircraft engine in-flight diagnostics is demonstrated.
Lee, Juneyoung; Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi
2015-01-01
Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies. PMID:26576107
Interpretation of bedside chest X-rays in the ICU: is the radiologist still needed?
Martini, Katharina; Ganter, Christoph; Maggiorini, Marco; Winklehner, Anna; Leupi-Skibinski, Katarzyna E; Frauenfelder, Thomas; Nguyen-Kim, Thi Dan Linh
2015-01-01
To compare diagnostic accuracy of intensivists to radiologists in reading bedside chest X-rays. In a retrospective trial, 33 bedside chest X-rays were evaluated by five radiologists and five intensivists with different experience. Images were evaluated for devices and lung pathologies. Interobserver agreement and diagnostic accuracy were calculated. Computed tomography served as reference standard. Seniors had higher diagnostic accuracy than residents (mean-ExpB(Senior)=1.456; mean-ExpB(Resident)=1.635). Interobserver agreement for installations was more homogenously distributed between radiologists compared to intensivists (ExpB(Rad)=1.204-1.672; ExpB(Int)=1.005-2.368). Seniors had comparable diagnostic accuracy. No significant difference in diagnostic performance was seen between seniors of both disciplines, whereas the resident intensivists might still benefit from an interdisciplinary dialogue. Copyright © 2015 Elsevier Inc. All rights reserved.
Preliminary report on aerotoxic syndrome (AS) and the need for diagnostic neurophysiological tests.
Hale, Margaret A; Al-Seffar, Judith A
2009-09-01
Researchers have found, in studies carried out over several years, that many passengers and crew, following their recent flights in commercial jet aeroplanes, have become unwell, with a range of symptoms in common. This condition, which has not yet been officially recognised, is called Aerotoxic Syndrome (AS). It seems to be caused, primarily, by neurotoxic organophosphates contaminating the air circulating in jet cabins. Patients with such symptoms may visit their GPs, who then arrange diagnostic tests. Some of their symptoms fall within the jurisdiction of diagnostic neurophysiological investigations, but neurophysiology practitioners may be unaware of this syndrome. Until AS is officially recognised as an illness, and guidelines for diagnostic procedures established, patients requiring specific investigations may not be appropriately referred, or tests may be performed unnecessarily. This report seeks to stimulate debate within the field, and facilitate studies, if needed, to help define the diagnostic criteria.
Rapid diagnostic tests for malaria
Daily, Jennifer; Hotte, Nora; Dolkart, Caitlin; Cunningham, Jane; Yadav, Prashant
2015-01-01
Abstract Maintaining quality, competitiveness and innovation in global health technology is a constant challenge for manufacturers, while affordability, access and equity are challenges for governments and international agencies. In this paper we discuss these issues with reference to rapid diagnostic tests for malaria. Strategies to control and eliminate malaria depend on early and accurate diagnosis. Rapid diagnostic tests for malaria require little training and equipment and can be performed by non-specialists in remote settings. Use of these tests has expanded significantly over the last few years, following recommendations to test all suspected malaria cases before treatment and the implementation of an evaluation programme to assess the performance of the malaria rapid diagnostic tests. Despite these gains, challenges exist that, if not addressed, could jeopardize the progress made to date. We discuss recent developments in rapid diagnostic tests for malaria, highlight some of the challenges and provide suggestions to address them. PMID:26668438
Evaluation of the accuracy of estimated baseline serum creatinine for acute kidney injury diagnosis.
Hatakeyama, Yutaka; Horino, Taro; Nagata, Keitaro; Kataoka, Hiromi; Matsumoto, Tatsuki; Terada, Yoshio; Okuhara, Yoshiyasu
2018-04-01
Modern epidemiologic studies of acute kidney injury (AKI) have been facilitated by the increasing availability of electronic medical records. However, pre-morbid reference serum creatinine (SCr) data are often unavailable in such records. Investigators substitute estimated baseline SCr with the eGFR 75 approach, instead of using actually measured baseline SCr. Here, we evaluated the accuracy of estimated baseline SCr for AKI diagnosis in the Japanese population. Inpatients and outpatients aged 18-80 years were retrospectively enrolled. AKI was diagnosed according to the Kidney Disease Improving Global Outcomes (KDIGO) criteria, using SCr levels. The non-AKI and AKI groups were selected using the following criteria: increase 1.5 times greater than baseline SCr ("baseline SCr") or increase 0.3 mg/dL greater than baseline SCr in 48 h ("increase in 48 h"). AKI accuracy defined by the estimated reference SCr, the average SCr value of the non-AKI population (eb-GFR-A approach), or the back-calculated SCr from fixed eGFR = 75 mL/min/1.73 m 2 (eGFR 75 approach, or, eb-GFR-B approach in this study), was evaluated. We analyzed data from 131,358 Japanese patients. The number of patients with reference baseline SCr in the non-AKI and AKI patients were 29,834 and 8952, respectively. For AKI patients diagnosed using "baseline SCr", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 63.5 and 57.7%, respectively, while in AKI diagnosed using "increase in 48 h", the AKI diagnostic accuracy rates as defined by eb-GFR-A and eb-GFR-B were 78.7 and 75.1%, respectively. In non-AKI patients, false-positive rates of AKI misdiagnosed via eb-GFR-A and eb-GFR-B were 7.4 and 6.8%, respectively. AKI diagnosis using the average SCr value of the general population may yield more accurate results than diagnosis using the eGFR 75 approach when the reference SCr is unavailable.
Applications of digital processing for noise removal from plasma diagnostics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kane, R.J.; Candy, J.V.; Casper, T.A.
1985-11-11
The use of digital signal techniques for removal of noise components present in plasma diagnostic signals is discussed, particularly with reference to diamagnetic loop signals. These signals contain noise due to power supply ripple in addition to plasma characteristics. The application of noise canceling techniques, such as adaptive noise canceling and model-based estimation, will be discussed. The use of computer codes such as SIG is described. 19 refs., 5 figs.
Rambaud-Althaus, Clotilde; Althaus, Fabrice; Genton, Blaise; D'Acremont, Valérie
2015-04-01
Pneumonia is the biggest cause of deaths in young children in developing countries, but early diagnosis and intervention can effectively reduce mortality. We aimed to assess the diagnostic value of clinical signs and symptoms to identify radiological pneumonia in children younger than 5 years and to review the accuracy of WHO criteria for diagnosis of clinical pneumonia. We searched Medline (PubMed), Embase (Ovid), the Cochrane Database of Systematic Reviews, and reference lists of relevant studies, without date restrictions, to identify articles assessing clinical predictors of radiological pneumonia in children. Selection was based on: design (diagnostic accuracy studies), target disease (pneumonia), participants (children aged <5 years), setting (ambulatory or hospital care), index test (clinical features), and reference standard (chest radiography). Quality assessment was based on the 2011 Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria. For each index test, we calculated sensitivity and specificity and, when the tests were assessed in four or more studies, calculated pooled estimates with use of bivariate model and hierarchical summary receiver operation characteristics plots for meta-analysis. We included 18 articles in our analysis. WHO-approved signs age-related fast breathing (six studies; pooled sensitivity 0·62, 95% CI 0·26-0·89; specificity 0·59, 0·29-0·84) and lower chest wall indrawing (four studies; 0·48, 0·16-0·82; 0·72, 0·47-0·89) showed poor diagnostic performance in the meta-analysis. Features with the highest pooled positive likelihood ratios were respiratory rate higher than 50 breaths per min (1·90, 1·45-2·48), grunting (1·78, 1·10-2·88), chest indrawing (1·76, 0·86-3·58), and nasal flaring (1·75, 1·20-2·56). Features with the lowest pooled negative likelihood ratio were cough (0·30, 0·09-0·96), history of fever (0·53, 0·41-0·69), and respiratory rate higher than 40 breaths per min (0·43, 0·23-0·83). Not one clinical feature was sufficient to diagnose pneumonia definitively. Combination of clinical features in a decision tree might improve diagnostic performance, but the addition of new point-of-care tests for diagnosis of bacterial pneumonia would help to attain an acceptable level of accuracy. Swiss National Science Foundation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F
2016-08-01
Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.
Diagnostic properties of C-reactive protein for detecting pneumonia in children.
Koster, Madieke J; Broekhuizen, Berna D L; Minnaard, Margaretha C; Balemans, Walter A F; Hopstaken, Rogier M; de Jong, Pim A; Verheij, Theo J M
2013-07-01
The diagnostic value of C-reactive protein (CRP) level for pneumonia in children is unknown. As a first step in the assessment of the value of CRP, a diagnostic study was performed in children at an emergency department (ED). In this cross-sectional study, data were retrospectively collected from children presenting with suspected pneumonia at the ED of Antonius Hospital Nieuwegein in The Netherlands between January 2007 and January 2012. Diagnostic outcome was pneumonia yes/no according to independent radiologist. (Un)adjusted association between CRP level and pneumonia and diagnostic value of CRP were calculated. Of 687 presenting children, 286 underwent both CRP measurement and chest radiography. 148 had pneumonia (52%). The proportion of pneumonia increased with CRP level. Negative predictive values declined, but positive predictive values increased with higher CRP thresholds. Univariable odds ratio for the association between CRP level and pneumonia was 1.2 (95% CI 1.11-1.21) per 10 mg/L increase. After adjustment for baseline characteristics CRP level remained associated with pneumonia. CRP level has independent diagnostic value for pneumonia in children presenting at the ED with suspected pneumonia, but low levels do not exclude pneumonia in this setting. These results prompt evaluation of CRP in primary care children with LRTI. Copyright © 2013 Elsevier Ltd. All rights reserved.
Azer, Samy A; AlSwaidan, Nourah M; Alshwairikh, Lama A; AlShammari, Jumana M
2015-10-06
To evaluate accuracy of content and readability level of English Wikipedia articles on cardiovascular diseases, using quality and readability tools. Wikipedia was searched on the 6 October 2013 for articles on cardiovascular diseases. Using a modified DISCERN (DISCERN is an instrument widely used in assessing online resources), articles were independently scored by three assessors. The readability was calculated using Flesch-Kincaid Grade Level. The inter-rater agreement between evaluators was calculated using the Fleiss κ scale. This study was based on 47 English Wikipedia entries on cardiovascular diseases. The DISCERN scores had a median=33 (IQR=6). Four articles (8.5%) were of good quality (DISCERN score 40-50), 39 (83%) moderate (DISCERN 30-39) and 4 (8.5%) were poor (DISCERN 10-29). Although the entries covered the aetiology and the clinical picture, there were deficiencies in the pathophysiology of diseases, signs and symptoms, diagnostic approaches and treatment. The number of references varied from 1 to 127 references; 25.9±29.4 (mean±SD). Several problems were identified in the list of references and citations made in the articles. The readability of articles was 14.3±1.7 (mean±SD); consistent with the readability level for college students. In comparison, Harrison's Principles of Internal Medicine 18th edition had more tables, less references and no significant difference in number of graphs, images, illustrations or readability level. The overall agreement between the evaluators was good (Fleiss κ 0.718 (95% CI 0.57 to 0.83). The Wikipedia entries are not aimed at a medical audience and should not be used as a substitute to recommended medical resources. Course designers and students should be aware that Wikipedia entries on cardiovascular diseases lack accuracy, predominantly due to errors of omission. Further improvement of the Wikipedia content of cardiovascular entries would be needed before they could be considered a supplementary resource. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Hua, Bin; Abbas, Estelle; Hayes, Alan; Ryan, Peter; Nelson, Lisa; O'Brien, Kylie
2012-11-01
Chinese medicine (CM) has its own diagnostic indicators that are used as evidence of change in a patient's condition. The majority of studies investigating efficacy of Chinese herbal medicine (CHM) have utilized biomedical diagnostic endpoints. For CM clinical diagnostic variables to be incorporated into clinical trial designs, there would need to be evidence that these diagnostic variables are reliable. Previous studies have indicated that the reliability of CM syndrome diagnosis is variable. Little information is known about where the variability stems from--the basic data collection level or the synthesis of diagnostic data, or both. No previous studies have investigated systematically the reliability of all four diagnostic methods used in the CM diagnostic process (Inquiry, Inspection, Auscultation/Olfaction, and Palpation). The objective of this study was to assess the inter-rater reliability of data collected using the four diagnostic methods of CM in Australian patients with knee osteoarthritis (OA), in order to investigate if CM variables could be used with confidence as diagnostic endpoints in a clinical trial investigating the efficacy of a CHM in treating OA. An inter-rater reliability study was conducted as a substudy of a clinical trial investigating the treatment of knee OA with Chinese herbal medicine. Two (2) experienced CM practitioners conducted a CM examination separately, within 2 hours of each other, in 40 participants. A CM assessment form was utilized to record the diagnostic data. Cohen's κ coefficient was used as a measure of the level of agreement between 2 practitioners. There was a relatively good level of agreement for Inquiry and Auscultation variables, and, in general, a low level of agreement for (visual) Inspection and Palpation variables. There was variation in the level of agreement between 2 practitioners on clinical information collected using the Four Diagnostic Methods of a CM examination. Some aspects of CM diagnosis appear to be reliable, while others are not. Based on these results, it was inappropriate to use CM diagnostic variables as diagnostic endpoints in the main study, which was an investigation of efficacy of CHM treatment of knee OA.
Kelder, Johannes C; Cowie, Martin R; McDonagh, Theresa A; Hardman, Suzanna M C; Grobbee, Diederick E; Cost, Bernard; Hoes, Arno W
2011-06-01
Diagnosing early stages of heart failure with mild symptoms is difficult. B-type natriuretic peptide (BNP) has promising biochemical test characteristics, but its diagnostic yield on top of readily available diagnostic knowledge has not been sufficiently quantified in early stages of heart failure. To quantify the added diagnostic value of BNP for the diagnosis of heart failure in a population relevant to GPs and validate the findings in an independent primary care patient population. Individual patient data meta-analysis followed by external validation. The additional diagnostic yield of BNP above standard clinical information was compared with ECG and chest x-ray results. Derivation was performed on two existing datasets from Hillingdon (n=127) and Rotterdam (n=149) while the UK Natriuretic Peptide Study (n=306) served as validation dataset. Included were patients with suspected heart failure referred to a rapid-access diagnostic outpatient clinic. Case definition was according to the ESC guideline. Logistic regression was used to assess discrimination (with the c-statistic) and calibration. Of the 276 patients in the derivation set, 30.8% had heart failure. The clinical model (encompassing age, gender, known coronary artery disease, diabetes, orthopnoea, elevated jugular venous pressure, crackles, pitting oedema and S3 gallop) had a c-statistic of 0.79. Adding, respectively, chest x-ray results, ECG results or BNP to the clinical model increased the c-statistic to 0.84, 0.85 and 0.92. Neither ECG nor chest x-ray added significantly to the 'clinical plus BNP' model. All models had adequate calibration. The 'clinical plus BNP' diagnostic model performed well in an independent cohort with comparable inclusion criteria (c-statistic=0.91 and adequate calibration). Using separate cut-off values for 'ruling in' (typically implying referral for echocardiography) and for 'ruling out' heart failure--creating a grey zone--resulted in insufficient proportions of patients with a correct diagnosis. BNP has considerable diagnostic value in addition to signs and symptoms in patients suspected of heart failure in primary care. However, using BNP alone with the currently recommended cut-off levels is not sufficient to make a reliable diagnosis of heart failure.
Pretty, Iain A; Maupomé, Gerardo
2004-04-01
Dentists are involved in diagnosing disease in every aspect of their clinical practice. A range of tests, systems, guides and equipment--which can be generally referred to as diagnostic procedures--are available to aid in diagnostic decision making. In this era of evidence-based dentistry, and given the increasing demand for diagnostic accuracy and properly targeted health care, it is important to assess the value of such diagnostic procedures. Doing so allows dentists to weight appropriately the information these procedures supply, to purchase new equipment if it proves more reliable than existing equipment or even to discard a commonly used procedure if it is shown to be unreliable. This article, the first in a 6-part series, defines several concepts used to express the usefulness of diagnostic procedures, including reliability and validity, and describes some of their operating characteristics (statistical measures of performance), in particular, specificity and sensitivity. Subsequent articles in the series will discuss the value of diagnostic procedures used in daily dental practice and will compare today's most innovative procedures with established methods.
Cox, Linda; Williams, Brock; Sicherer, Scott; Oppenheimer, John; Sher, Larry; Hamilton, Robert; Golden, David
2008-12-01
The intended purpose of this monograph is to provide a general overview of allergy diagnostics for health care professionals who care for patients with allergic disease. For a more comprehensive review of allergy diagnostic testing, readers can refer to the Allergy Diagnostic Practice Parameters. A key message is that a positive allergy test result (skin or blood) indicates only the presence of allergen specific IgE (called sensitization). It does not necessarily mean clinical allergy (ie, allergic symptoms with exposure). It is important for this reason that the allergy evaluation be based on the patient's history and directed by a health care professional with sufficient understanding of allergy diagnostic testing to use the information obtained from his/her evaluation of the patient to determine (1) what allergy diagnostic tests to order, (2) how to interpret the allergy diagnostic test results, and (3) how to use the information obtained from the allergy evaluation to develop an appropriate therapeutic treatment plan.
Wynants, Laure; Timmerman, Dirk; Verbakel, Jan Y; Testa, Antonia; Savelli, Luca; Fischerova, Daniela; Franchi, Dorella; Van Holsbeke, Caroline; Epstein, Elisabeth; Froyman, Wouter; Guerriero, Stefano; Rossi, Alberto; Fruscio, Robert; Leone, Francesco Pg; Bourne, Tom; Valentin, Lil; Van Calster, Ben
2017-09-01
Purpose: To evaluate the utility of preoperative diagnostic models for ovarian cancer based on ultrasound and/or biomarkers for referring patients to specialized oncology care. The investigated models were RMI, ROMA, and 3 models from the International Ovarian Tumor Analysis (IOTA) group [LR2, ADNEX, and the Simple Rules risk score (SRRisk)]. Experimental Design: A secondary analysis of prospectively collected data from 2 cross-sectional cohort studies was performed to externally validate diagnostic models. A total of 2,763 patients (2,403 in dataset 1 and 360 in dataset 2) from 18 centers (11 oncology centers and 7 nononcology hospitals) in 6 countries participated. Excised tissue was histologically classified as benign or malignant. The clinical utility of the preoperative diagnostic models was assessed with net benefit (NB) at a range of risk thresholds (5%-50% risk of malignancy) to refer patients to specialized oncology care. We visualized results with decision curves and generated bootstrap confidence intervals. Results: The prevalence of malignancy was 41% in dataset 1 and 40% in dataset 2. For thresholds up to 10% to 15%, RMI and ROMA had a lower NB than referring all patients. SRRisks and ADNEX demonstrated the highest NB. At a threshold of 20%, the NBs of ADNEX, SRrisks, and RMI were 0.348, 0.350, and 0.270, respectively. Results by menopausal status and type of center (oncology vs. nononcology) were similar. Conclusions: All tested IOTA methods, especially ADNEX and SRRisks, are clinically more useful than RMI and ROMA to select patients with adnexal masses for specialized oncology care. Clin Cancer Res; 23(17); 5082-90. ©2017 AACR . ©2017 American Association for Cancer Research.
Kutz, Alexander; Hausfater, Pierre; Oppert, Michael; Alan, Murat; Grolimund, Eva; Gast, Claire; Alonso, Christine; Wissmann, Christoph; Kuehn, Christian; Bernard, Maguy; Huber, Andreas; Mueller, Beat; Schuetz, Philipp
2016-04-01
Procalcitonin (PCT) is increasingly being used for the diagnostic and prognostic work up of patients with suspected infections in the emergency department (ED). Recently, B·R·A·H·M·S PCT direct, the first high sensitive point-of-care test (POCT), has been developed for fast PCT measurement on capillary or venous blood samples. This is a prospective, international comparison study conducted in three European EDs. Consecutive patients with suspicion of bacterial infection were included. Duplicate determination of PCT was performed in capillary (fingertip) and venous whole blood (EDTA), and compared to the reference method. The diagnostic accuracy was evaluated by correlation and concordance analyses. Three hundred and three patients were included over a 6-month period (60.4% male, median age 65.2 years). The correlation between capillary or venous whole blood and the reference method was excellent: r2=0.96 and 0.97, sensitivity 88.1% and 93.0%, specificity 96.5% and 96.8%, concordance 93% and 95%, respectively at a 0.25 μg/L threshold. No significant bias was observed (-0.04 and -0.02 for capillary and venous whole blood) although there were 6.8% and 5.1% outliers, respectively. B·R·A·H·M·S PCT direct had a shorter time to result as compared to the reference method (25 vs. 144 min, difference 119 min, 95% CI 110-134 min, p<0.0001). This study found a high diagnostic accuracy and a faster time to result of B·R·A·H·M·S PCT direct in the ED setting, allowing shortening time to therapy and a more wide-spread use of PCT.
Khairnar, Krishna; Martin, Donald; Lau, Rachel; Ralevski, Filip; Pillai, Dylan R
2009-12-09
Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected malaria infection were collected between 2007 and 2009 at the reference public health laboratory. These specimens were assessed by reference microscopy, multipex real-time quantitative polymerase chain reaction (QPCR), and two rapid diagnostic immuno-chromatographic tests (ICT) in a blinded manner. Key clinical laboratory parameters such as limit of detection (LOD) analysis on clinical specimens by parasite stage, inter-reader variability of ICTs, staffing implications, quality assurance and cost analysis were evaluated. QPCR is the most analytically sensitive method (sensitivity 99.41%), followed by CARESTART (sensitivity 88.24%), and BINAXNOW (sensitivity 86.47%) for the diagnosis of malaria in returning travelers when compared to reference microscopy. However, microscopy was unable to specifically identify Plasmodia spp. in 18 out of 170 positive samples by QPCR. Moreover, the 17 samples that were negative by microscopy and positive by QPCR were also positive by ICTs. Quality assurance was achieved for QPCR by exchanging a blinded proficiency panel with another reference laboratory. The Kappa value of inter-reader variability among three readers for BINAXNOW and CARESTART was calculated to be 0.872 and 0.898 respectively. Serial dilution studies demonstrated that the QPCR cycle threshold correlates linearly with parasitemia (R(2) = 0.9746) in a clinically relevant dynamic range and retains a LOD of 11 rDNA copies/microl for P. falciparum, which was several log lower than reference microscopy and ICTs. LOD for QPCR is affected not only by parasitemia but the parasite stage distribution of each clinical specimen. QPCR was approximately 6-fold more costly than reference microscopy. These data suggest that multiplex QPCR although more costly confers a significant diagnostic advantage in terms of LOD compared to reference microscopy and ICTs for all four species. Quality assurance of QPCR is essential to the maintenance of proficiency in the clinical laboratory. ICTs showed good concordance between readers however lacked sensitivity for non-falciparum species due to antigenic differences and low parasitemia. Multiplex QPCR but not ICTs is an essential adjunct to microscopy in the reference laboratory detection of malaria species specifically due to the superior LOD. ICTs are better suited to the non-reference laboratory where lower specimen volumes challenge microscopy proficiency in the non-endemic setting.
Arduino Based Infant Monitoring System
NASA Astrophysics Data System (ADS)
Farhanah Mohamad Ishak, Daing Noor; Jamil, Muhammad Mahadi Abdul; Ambar, Radzi
2017-08-01
This paper proposes a system for monitoring infant in an incubator and records the relevant data into a computer. The data recorded by the system can be further referred by the neonatal intensive care unit (NICU) personnel for diagnostic or research purposes. The study focuses on designing the monitoring system that consists of an incubator equipped with humidity sensor to measure the humidity level, and a pulse sensor that can be attached on an infant placed inside the incubator to monitor infant’s heart pulse. The measurement results which are the pulse rate and humidity level are sent to the PC via Arduino microcontroller. The advantage of this system will be that in the future, it may also enable doctors to closely monitor the infant condition through local area network and internet. This work is aimed as an example of an application that contributes towards remote tele-health monitoring system.
Incorporation of a clinical history into the interpretation process in a PACS environment
NASA Astrophysics Data System (ADS)
Cooperstein, Lawrence A.; Good, Barbara C.; Miketic, Linda M.; Tabor, Ellen K.; Yousem, Samuel A.; King, Jill L.; Gennari, Rose C.; Felice, Marc A.; Sidorovich, Kathleen
1990-08-01
In a large-scale, multi-reader study to investigate questions surrounding the issue of the implementation of picture archiving and communications systems (PACS) into the modern radiology environment, we examined the effect that the incorporation of a clinical history into the reading process would have on levels of diagnostic accuracy. Because we wanted to test the inclusion of the clinical history in an environment as close to that of the clinical situation as possible, we defined "history" to be a concise, objective, and potentially computer-extractable version of what appears in the patient records, including a statement from the referring physician when this is available. In a series of studies, four radiologists interpreted 247 posteroanterior normal and abnormal chest images on conventional film both with and without accompanying patient histories; five radiologists read the same number of images presented on a high-resolution video workstation with and without clinical histories. There were no significant differences (p = .05) in diagnostic accuracy rates with or without clinical history for either the film or the workstation in cases of interstitial disease, nodules, or pneumothorax. Diagnostic accuracy for the radiologists as a group was not affected by the presence of the clinical history. We concluded that for the interpretation of these abnormalities, the incorporation of clinical history with images in the PACS environment should not be a major goal.
Tuberculosis mimicking lung cancer
Hammen, I.
2015-01-01
Tuberculosis (TB) is well known as a diagnostic chameleon and can resemble malignancy. In thorax TB can be manifested as pulmonary infiltrates and/or mediastinal lymphadenopathy. In low incident countries with high incidence of lung cancer and varying clinical presentations, TB often gets misdiagnosed with the result of delayed treatment start and unnecessary diagnostic procedures. Our case report presents two patients, who were referred to the Thorax diagnostic centre at the Department of Respiratory Medicine, Odense University Hospital, with presumptive diagnosis of neoplasm and had proved lung TB with no evidence of malignancy instead. In the first case diagnosis was confirmed after thoracotomy, in the second case after bronchoscopy. PMID:26744652
Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A
2014-02-01
Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.
SU-E-I-33: Establishment of CT Diagnostic Reference Levels in Province Nova Scotia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonkopi, E; Abdolell, M; Duffy, S
2015-06-15
Purpose: To evaluate patient radiation dose from the most frequently performed CT examinations and to establish provincial diagnostic reference levels (DRLs) as a tool for protocol optimization. Methods: The study investigated the following CT examinations: head, chest, abdomen/pelvis, and chest/abdomen/pelvis (CAP). Dose data, volume CT dose index (CTDIvol) and dose-length product (DLP), were collected from 15 CT scanners installed during 2004–2014 in 11 hospital sites of Nova Scotia. All scanners had dose modulation options and multislice capability (16–128 detector rows). The sample for each protocol included 15 average size patients (70±20 kg). Provincial DRLs were calculated as the 75th percentilemore » of patient dose distributions. The differences in dose between hospitals were evaluated with a single factor ANOVA statistical test. Generalized linear modeling was used to determine the factors associated with higher radiation dose. A sample of 36 abdominal studies performed on three different scanners was blinded and randomized for an assessment by an experienced radiologist who graded the imaging quality of anatomic structures. Results: Data for 900 patients were collected. The DRLs were proposed using CTDIvol (mGy) and DLP (mGy*cm) values for CT head (67 and 1049, respectively), chest (12 and 393), abdomen/pelvis (16 and 717), and CAP (14 and 1034). These DRLs were lower than the published national data except for the head CTDIvol. The differences between the means of the dose distributions from each scanner were statistically significant (p<0.05) for all examinations. A very weak correlation was found between the dose and the scanner age or the number of slices with Pearson’s correlation coefficients of 0.011–0.315. The blinded analysis of image quality demonstrated no clinically significant difference except for the noise category. Conclusion: Provincial DRLs were established for typical CT examinations. The variations in dose between the hospitals suggested a large potential for optimization of examinations. Radiology Research Foundation grant.« less
MO-FG-CAMPUS-IeP1-03: Establishment of Provincial Diagnostic Reference Levels in Pediatric Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonkopi, E; Queen Elizabeth II Health Sciences Ctr; O’Brien, K
Purpose: To establish provincial diagnostic reference levels (DRLs) in pediatric general radiography and computed tomography (CT) as a tool for the optimization of exposure parameters. Methods: Patient dose survey was conducted in the only pediatric hospital in the province of Nova Scotia. The DRLs were established as the 75th percentile of patient dose distributions in different age groups. For routine radiography projections the DRLs were determined in terms of entrance surface dose (ESD) calculated from the radiation output measurements and the tube current-exposure time product (mAs) recorded for each examination. Patient thickness was measured by the technologist during the examination.more » The CR and DR systems, employing respectively a fixed technique and phototiming, were evaluated separately; a two-tailed Student’s t-test was used to determine the significance of differences between the means of dose distributions. The CT studies included routine head, chest, abdomen/pelvis, and chest/abdomen/pelvis. The volume CT dose index (CTDIvol) and dose-length product (DLP) values were extracted retrospectively from PACS. The correction factors based on the effective diameter of the patient were applied to the CT dosimetry metrics based on the standard phantoms. Results: The provincial DRLs were established in the following age groups: newborn, 1, 5, 10, and 15 year olds. In general radiography the DR systems demonstrated slightly lower dose than the CR for all views, however the differences were not statistically significant (p > 0.05) for all examinations. In CT the provincial DRLs were lower than the published data, except for head DLPs in all age categories. This might be due to the small patient sample size in the survey. Future work will include additional CT data collection over an extended period of time. Conclusion: Provincial DRLs were established in the dedicated children’s hospital to provide guidance for the other facilities in examinations of pediatric patients.« less
The development of a quality appraisal tool for studies of diagnostic reliability (QAREL).
Lucas, Nicholas P; Macaskill, Petra; Irwig, Les; Bogduk, Nikolai
2010-08-01
In systematic reviews of the reliability of diagnostic tests, no quality assessment tool has been used consistently. The aim of this study was to develop a specific quality appraisal tool for studies of diagnostic reliability. Key principles for the quality of studies of diagnostic reliability were identified with reference to epidemiologic principles, existing quality appraisal checklists, and the Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) resources. Specific items that encompassed each of the principles were developed. Experts in diagnostic research provided feedback on the items that were to form the appraisal tool. This process was iterative and continued until consensus among experts was reached. The Quality Appraisal of Reliability Studies (QAREL) checklist includes 11 items that explore seven principles. Items cover the spectrum of subjects, spectrum of examiners, examiner blinding, order effects of examination, suitability of the time interval among repeated measurements, appropriate test application and interpretation, and appropriate statistical analysis. QAREL has been developed as a specific quality appraisal tool for studies of diagnostic reliability. The reliability of this tool in different contexts needs to be evaluated. Copyright (c) 2010 Elsevier Inc. All rights reserved.
Cost Implications of Value-Based Pricing for Companion Diagnostic Tests in Precision Medicine.
Zaric, Gregory S
2016-07-01
Many interpretations of personalized medicine, also referred to as precision medicine, include discussions of companion diagnostic tests that allow drugs to be targeted to those individuals who are most likely to benefit or that allow treatment to be designed in a way such that individuals who are unlikely to benefit do not receive treatment. Many authors have commented on the clinical and competitive implications of companion diagnostics, but there has been relatively little formal analysis of the cost implications of companion diagnostics, although cost reduction is often cited as a significant benefit of precision medicine. We investigate the potential impact on costs of precision medicine implemented through the use of companion diagnostics. We develop a framework in which the costs of companion diagnostic tests are determined by considerations of profit maximization and cost effectiveness. We analyze four scenarios that are defined by the incremental cost-effectiveness ratio of the new drug in the absence of a companion diagnostic test. We find that, in most scenarios, precision medicine strategies based on companion diagnostics should be expected to lead to increases in costs in the short term and that costs would fall only in a limited number of situations.
A systematic review of the PTSD Checklist's diagnostic accuracy studies using QUADAS.
McDonald, Scott D; Brown, Whitney L; Benesek, John P; Calhoun, Patrick S
2015-09-01
Despite the popularity of the PTSD Checklist (PCL) as a clinical screening test, there has been no comprehensive quality review of studies evaluating its diagnostic accuracy. A systematic quality assessment of 22 diagnostic accuracy studies of the English-language PCL using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) assessment tool was conducted to examine (a) the quality of diagnostic accuracy studies of the PCL, and (b) whether quality has improved since the 2003 STAndards for the Reporting of Diagnostic accuracy studies (STARD) initiative regarding reporting guidelines for diagnostic accuracy studies. Three raters independently applied the QUADAS tool to each study, and a consensus among the 4 authors is reported. Findings indicated that although studies generally met standards in several quality areas, there is still room for improvement. Areas for improvement include establishing representativeness, adequately describing clinical and demographic characteristics of the sample, and presenting better descriptions of important aspects of test and reference standard execution. Only 2 studies met each of the 14 quality criteria. In addition, study quality has not appreciably improved since the publication of the STARD Statement in 2003. Recommendations for the improvement of diagnostic accuracy studies of the PCL are discussed. (c) 2015 APA, all rights reserved).
Allison, Kimberly H; Reisch, Lisa M; Carney, Patricia A; Weaver, Donald L; Schnitt, Stuart J; O’Malley, Frances P; Geller, Berta M; Elmore, Joann G
2015-01-01
Aims To gain a better understanding of the reasons for diagnostic variability, with the aim of reducing the phenomenon. Methods and results In preparation for a study on the interpretation of breast specimens (B-PATH), a panel of three experienced breast pathologists reviewed 336 cases to develop consensus reference diagnoses. After independent assessment, cases coded as diagnostically discordant were discussed at consensus meetings. By the use of qualitative data analysis techniques, transcripts of 16 h of consensus meetings for a subset of 201 cases were analysed. Diagnostic variability could be attributed to three overall root causes: (i) pathologist-related; (ii) diagnostic coding/study methodology-related; and (iii) specimen-related. Most pathologist-related root causes were attributable to professional differences in pathologists’ opinions about whether the diagnostic criteria for a specific diagnosis were met, most frequently in cases of atypia. Diagnostic coding/study methodology-related root causes were primarily miscategorizations of descriptive text diagnoses, which led to the development of a standardized electronic diagnostic form (BPATH-Dx). Specimen-related root causes included artefacts, limited diagnostic material, and poor slide quality. After re-review and discussion, a consensus diagnosis could be assigned in all cases. Conclusions Diagnostic variability is related to multiple factors, but consensus conferences, standardized electronic reporting formats and comments on suboptimal specimen quality can be used to reduce diagnostic variability. PMID:24511905
Chockalingam, P S; Glasson, S S; Lohmander, L S
2013-02-01
We have previously shown the capacity of tenascin-C (TN-C) to induce inflammatory mediators and matrix degradation in vitro in human articular cartilage. The objective of the present study was to follow TN-C release into knee synovial fluid after acute joint injury or in joint disease, and to correlate TN-C levels with markers of cartilage matrix degradation and inflammation. Human knee synovial fluid samples (n = 164) were from a cross-sectional convenience cohort. Diagnostic groups were knee healthy reference, knee anterior cruciate ligament rupture, with or without concomitant meniscus lesions, isolated knee meniscus injury, acute inflammatory arthritis (AIA) and knee osteoarthritis (OA). TN-C was measured in synovial fluid samples using an enzyme-linked immunosorbent assay (ELISA) and results correlated to other cartilage markers. TN-C release was also monitored in joints of dogs that underwent knee instability surgery. Statistically significantly higher levels of TN-C compared to reference subjects were observed in the joint fluid of all human disease groups and in the dogs that underwent knee instability surgery. Statistically significant correlations were observed between the TN-C levels in the synovial fluid of the human patients and the levels of aggrecanase-dependent Ala-Arg-Gly-aggrecan (ARG-aggrecan) fragments and matrix metalloproteinases 1 and 3. We find highly elevated levels of TN-C in human knee joints after injury, AIA or OA that correlated with markers of cartilage degradation and inflammation. TN-C in synovial fluid may serve dual roles as a marker of joint damage and a stimulant of further joint degradation. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
Ashraf, Sania; Kao, Angie; Hugo, Cecilia; Christophel, Eva M; Fatunmbi, Bayo; Luchavez, Jennifer; Lilley, Ken; Bell, David
2012-10-24
Malaria diagnosis has received renewed interest in recent years, associated with the increasing accessibility of accurate diagnosis through the introduction of rapid diagnostic tests and new World Health Organization guidelines recommending parasite-based diagnosis prior to anti-malarial therapy. However, light microscopy, established over 100 years ago and frequently considered the reference standard for clinical diagnosis, has been neglected in control programmes and in the malaria literature and evidence suggests field standards are commonly poor. Microscopy remains the most accessible method for parasite quantitation, for drug efficacy monitoring, and as a reference of assessing other diagnostic tools. This mismatch between quality and need highlights the importance of the establishment of reliable standards and procedures for assessing and assuring quality. This paper describes the development, function and impact of a multi-country microscopy external quality assurance network set up for this purpose in Asia. Surveys were used for key informants and past participants for feedback on the quality assurance programme. Competency scores for each country from 14 participating countries were compiled for analyses using paired sample t-tests. In-depth interviews were conducted with key informants including the programme facilitators and national level microscopists. External assessments and limited retraining through a formalized programme based on a reference slide bank has demonstrated an increase in standards of competence of senior microscopists over a relatively short period of time, at a potentially sustainable cost. The network involved in the programme now exceeds 14 countries in the Asia-Pacific, and the methods are extended to other regions. While the impact on national programmes varies, it has translated in some instances into a strengthening of national microscopy standards and offers a possibility both for supporting revival of national microcopy programmes, and for the development of globally recognized standards of competency needed both for patient management and field research.
Tompuri, Tuomo; Lintu, Niina; Laitinen, Tomi; Lakka, Timo A
2017-08-09
Exercise testing by cycle ergometer allows to observe the interaction between oxygen uptake (VO 2 ) and workload (W), and VO 2 /W-slope can be used as a diagnostic tool. Respectively, peak oxygen uptake (VO 2 PEAK ) can be estimated by maximal workload. We aim to determine reference for VO 2 /W-slope among prepubertal children and define agreement between estimated and measured VO 2 PEAK . A total of 38 prepubertal children (20 girls) performed a maximal cycle ergometer test with respiratory gas analysis. VO 2 /W-slopes were computed using linear regression. Agreement analysis by Bland and Altman for estimated and measured VO 2 PEAK was carried out including limits of agreement (LA). Determinants for VO 2 /W-slopes and estimation bias were defined. VO2/W-slope was in both girls and boys ≥9·4 and did not change with exercise level, but the oxygen cost of exercise was higher among physically more active children. Estimated VO 2 PEAK had 6·4% coefficient of variation, and LA varied from 13% underestimation to 13% overestimation. Bias had a trend towards underestimation along lean mass proportional VO 2 PEAK . The primary determinant for estimation bias was VO2/W-slope (β = -0·65; P<0·001). The reference values for VO 2 /W-slope among healthy prepubertal children were similar to those published for adults and among adolescents. Estimated and measured VO 2 PEAK should not be considered to be interchangeable because of the variation in the relationship between VO 2 and W. On other hand, variation in the relationship between VO 2 and W enables that VO 2 /W-slope can be used as a diagnostic tool. © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Primary care REFerral for EchocaRdiogram (REFER) in heart failure: a diagnostic accuracy study
Taylor, Clare J; Roalfe, Andrea K; Iles, Rachel; Hobbs, FD Richard; Barton, P; Deeks, J; McCahon, D; Cowie, MR; Sutton, G; Davis, RC; Mant, J; McDonagh, T; Tait, L
2017-01-01
Background Symptoms of breathlessness, fatigue, and ankle swelling are common in general practice but deciding which patients are likely to have heart failure is challenging. Aim To evaluate the performance of a clinical decision rule (CDR), with or without N-Terminal pro-B type natriuretic peptide (NT-proBNP) assay, for identifying heart failure. Design and setting Prospective, observational, diagnostic validation study of patients aged >55 years, presenting with shortness of breath, lethargy, or ankle oedema, from 28 general practices in England. Method The outcome was test performance of the CDR and natriuretic peptide test in determining a diagnosis of heart failure. The reference standard was an expert consensus panel of three cardiologists. Results Three hundred and four participants were recruited, with 104 (34.2%; 95% confidence interval [CI] = 28.9 to 39.8) having a confirmed diagnosis of heart failure. The CDR+NT-proBNP had a sensitivity of 90.4% (95% CI = 83.0 to 95.3) and specificity 45.5% (95% CI = 38.5 to 52.7). NT-proBNP level alone with a cut-off <400 pg/ml had sensitivity 76.9% (95% CI = 67.6 to 84.6) and specificity 91.5% (95% CI = 86.7 to 95.0). At the lower cut-off of NT-proBNP <125 pg/ml, sensitivity was 94.2% (95% CI = 87.9 to 97.9) and specificity 49.0% (95% CI = 41.9 to 56.1). Conclusion At the low threshold of NT-proBNP <125 pg/ml, natriuretic peptide testing alone was better than a validated CDR+NT-proBNP in determining which patients presenting with symptoms went on to have a diagnosis of heart failure. The higher NT-proBNP threshold of 400 pg/ml may mean more than one in five patients with heart failure are not appropriately referred. Guideline natriuretic peptide thresholds may need to be revised. PMID:27919937