Uptake of prenatal diagnostic testing and the effectiveness of prenatal screening for Down syndrome.
Jaques, Alice M; Collins, Veronica R; Muggli, Evelyne E; Amor, David J; Francis, Ivan; Sheffield, Leslie J; Halliday, Jane L
2010-06-01
To map prenatal screening and diagnostic testing pathways in Victorian pregnant women during 2003 to 2004; measure the impact of prenatal diagnostic testing uptake on the effectiveness of prenatal screening for Down syndrome; and assess factors influencing uptake of diagnostic testing following screening. State-wide data collections of prenatal screening and diagnostic tests were linked to all Victorian births and pregnancy terminations for birth defects. Overall, 52% of women had a prenatal test (65 692/126 305); screening (44.9%), diagnostic testing (3.9%), or both (3.2%). Uptake of diagnostic testing was 71.4% (2390/3349) after an increased risk screen result, and 2.5% (1381/54 286) after a low risk result. Variation in uptake of diagnostic testing reduced the effectiveness of the screening program by 11.2%: from 87.4% (sensitivity - 125/143) to 76.2% (prenatal diagnoses of Down syndrome - 109/143). In both the increased and low risk groups, uptake was influenced by absolute numerical risk, as well as by the change in numerical risk from a priori risk. This comprehensive follow-up demonstrates clearly that numerical risk is being used to aid in decision making about confirmatory diagnostic testing. Collectively, these fundamental individual decisions will impact on the overall effectiveness of screening programmes for Down syndrome.
Validation of the Lollipop Test: A Diagnostic Screening Test of School Readiness.
ERIC Educational Resources Information Center
Chew, Alex L.; Morris, John D.
1984-01-01
The validity of the Lollipop Test: A Diagnostic Screening Test of School Readiness was examined using the Metropolitan Readiness Test (MRT), Level I, Form Q, as the criterion. Appreciable concurrent validity was found across test batteries. Implications for school readiness screening are discussed. (Author/BS)
Becker, Elizabeth A.; Griffith, Derek M.; West, Brady T.; Janz, Nancy K.; Resnicow, Ken; Morris, Arden M.
2015-01-01
Background Screening and post-symptomatic diagnostic testing are often conflated in cancer screening surveillance research. We examined the error in estimated colorectal cancer (CRC) screening prevalence due to the conflation of screening and diagnostic testing. Methods Using data from the 2008 National Health Interview Survey, we compared weighted prevalence estimates of the use of all testing (screening and diagnostic) and screening in at-risk adults, and calculated the overestimation of screening prevalence across socio-demographic groups. Results The population screening prevalence was overestimated by 23.3%, and the level of overestimation varied widely across socio-demographic groups (median 22.6%, mean 24.8%). The highest levels of overestimation were in non-Hispanic White females (27.4%), adults ages 50–54 (32.0%), and those with the highest socioeconomic vulnerability (low educational attainment (31.3%), low poverty ratio (32.5%), no usual source of health care (54.4%) and not insured (51.6%)) (all p-values < 0.001). Conclusions When the impetus for testing was not included, CRC screening prevalence was overestimated, and patterns of overestimation often aligned with social and economic vulnerability. These results are of concern to researchers who utilize survey data from the Behavioral Risk Factor Surveillance System (BRFSS) to assess cancer screening behaviors, as it is currently not designed to distinguish diagnostic testing from screening. Impact Surveillance research in cancer screening that does not consider the impetus for testing risks measurement error of screening prevalence, impeding progress toward improving population health. Ultimately, in order to craft relevant screening benchmarks and interventions, we must look beyond ‘what’ and ‘when’ and include ‘why.’ PMID:26491056
Variation in Women's Understanding of Prenatal Testing.
Bryant, Allison S; Norton, Mary E; Nakagawa, Sanae; Bishop, Judith T; Pena, Sherri; Gregorich, Steven E; Kuppermann, Miriam
2015-06-01
To investigate women's understanding of prenatal testing options and of their own experience with screening, diagnostic genetic testing, or both. This was a secondary analysis of data from a randomized controlled trial of enhanced information and values clarification regarding prenatal genetic testing in the absence of financial barriers to testing. Women in the third trimester of pregnancy were asked whether they had discussed prenatal genetic testing with their health care providers, whether they understood this testing was optional, and whether they had undergone testing during their pregnancy. Multivariable logistic regression models were fit to determine independent predictors of these outcomes. Data were available from 710 study participants. Discussions about screening tests were reported by 654 participants (92%); only 412 (58%) reported discussing diagnostic testing. That screening and diagnostic testing were optional was evident to approximately two thirds of women (n=470 and 455, respectively). Recall of actual tests undergone was correct for 626 (88%) for screening and for 700 (99%) for diagnostic testing. Racial, ethnic and socioeconomic variation existed in the understanding of whether screening and diagnostic tests were optional and in the correct recall of whether screening had been undertaken in the current pregnancy. In the usual care group, women receiving care in low-income settings were less likely to recall being offered diagnostic testing (adjusted odds ratio 0.23 [0.14-0.39]). Disparities exist in women's recall of prenatal genetic testing discussions and their understanding of their own experience. Interventions that explain testing options to women and help clarify their preferences may help to eliminate these differences.
Routine opt-out rapid HIV screening and detection of HIV infection in emergency department patients.
Haukoos, Jason S; Hopkins, Emily; Conroy, Amy A; Silverman, Morgan; Byyny, Richard L; Eisert, Sheri; Thrun, Mark W; Wilson, Michael L; Hutchinson, Angela B; Forsyth, Jessica; Johnson, Steven C; Heffelfinger, James D
2010-07-21
The Centers for Disease Control and Prevention (CDC) recommends routine (nontargeted) opt-out HIV screening in health care settings, including emergency departments (EDs), where the prevalence of undiagnosed infection is 0.1% or greater. The utility of this approach in EDs remains unknown. To determine whether nontargeted opt-out rapid HIV screening in the ED was associated with identification of more patients with newly diagnosed HIV infection than physician-directed diagnostic rapid HIV testing. Quasi-experimental equivalent time-samples design in an urban public safety-net hospital with an approximate annual ED census of 55,000 patient visits. Patients were 16 years or older and capable of providing consent for rapid HIV testing. Nontargeted opt-out rapid HIV screening and physician-directed diagnostic rapid HIV testing alternated in sequential 4-month time intervals between April 15, 2007, and April 15, 2009. Number of patients with newly identified HIV infection and the association between nontargeted opt-out rapid HIV screening and identification of HIV infection. In the opt-out phase, of 28,043 eligible ED patients, 6933 patients (25%) completed HIV testing (6702 patients were screened; 231 patients were diagnostically tested). Ten of 6702 patients (0.15%; 95% CI, 0.07%-0.27%) who did not decline HIV screening in the opt-out phase had new HIV diagnoses, and 5 of 231 patients (2.2%; 95% CI, 0.7%-5.0%) who were diagnostically tested during the opt-out phase had new HIV diagnoses. In the diagnostic phase, of 29,925 eligible patients, 243 (0.8%) completed HIV testing. Of these, 4 patients (1.6%; 95% CI, 0.5%-4.2%) had new diagnoses. The prevalence of new HIV diagnoses in the opt-out phase (including those diagnostically tested) and in the diagnostic phase was 15 in 28,043 (0.05%; 95% CI, 0.03%-0.09%) and 4 in 29,925 (0.01%; 95% CI, 0.004%-0.03%), respectively. Nontargeted opt-out HIV screening was independently associated with new HIV diagnoses (risk ratio, 3.6; 95% CI, 1.2-10.8) when adjusting for patient demographics, insurance status, and whether diagnostic testing was performed in the opt-out phase. The median CD4 cell count for those with new HIV diagnoses in the opt-out phase (including those diagnostically tested) and in the diagnostic phase was 69/microL (IQR, 17-430) and 13/microL (IQR, 11-15) , respectively (P = .02). Nontargeted opt-out rapid HIV screening in the ED, vs diagnostic testing, was associated with identification of a modestly increased number of patients with new HIV diagnoses, most of whom were identified late in the course of disease.
Comprehensive Carrier Screening and Molecular Diagnostic Testing for Recessive Childhood Diseases
Kingsmore, Stephen
2012-01-01
Of 7,028 disorders with suspected Mendelian inheritance, 1,139 are recessive and have an established molecular basis. Although individually uncommon, Mendelian diseases collectively account for ~20% of infant mortality and ~18% of pediatric hospitalizations. Molecular diagnostic testing is currently available for only ~300 recessive disorders. Preconception screening, together with genetic counseling of carriers, has resulted in remarkable declines in the incidence of several severe recessive diseases including Tay-Sachs disease and cystic fibrosis. However, extension of preconception screening and molecular diagnostic testing to most recessive disease genes has hitherto been impractical. Recently, we reported a preconception carrier screen / molecular diagnostic test for 448 recessive childhood diseases. The current status of this test is reviewed here. Currently, this reports analytical validity of the comprehensive carrier test. As the clinical validity and clinical utility in the contexts described is ascertained, this article will be updated. PMID:22872815
Are overreferrals on developmental screening tests really a problem?
Glascoe, F P
2001-01-01
Developmental screening tests, even those meeting standards for screening test accuracy, produce numerous false-positive results for 15% to 30% of children. This is thought to produce unnecessary referrals for diagnostic testing or special services and increase the cost of screening programs. To explore whether children who pass screening tests differ in important ways from those who do not and to determine whether children overreferred for testing benefit from the scrutiny of diagnostic testing and treatment planning. Subjects were a national sample of 512 parents and their children (age range of the children, 7 months to 8 years) who participated in validation studies of various screening tests. Psychological examiners adhering to standardized directions obtained informed consent and administered at least 2 developmental screening measures (the Brigance Screens, the Battelle Developmental Inventory Screening Test, the Denver-II, and the Parents' Evaluations of Developmental Status) and a concurrent battery of diagnostic measures, including tests of intelligence, language, and academic achievement (for children aged 2(1/2) years and older). The performance on diagnostic measures of children who failed screening but were not found to have a disability (false positives) was compared with that of children who passed screening and did not have a disability on diagnostic testing (true negatives). Children with false-positive scores performed significantly (P<.001) lower on diagnostic measures than did children with true-negative scores. The false-positive group had scores in adaptive behavior, language, intelligence, and academic achievement that were 9 to 14 points lower than the scores of those in the true-negative group. When viewing the likelihood of scoring below the 25th percentile on diagnostic measures, children with false-positive scores had a relative risk of 2.6 in adaptive behavior (95% confidence interval [CI], 1.67-4.21), 3.1 in language skills (95% CI, 1.90-5.20), 6.7 on intelligence tests (95% CI, 3.28-13.50), and 4.9 on academic measures (95% CI, 2.61-9.28). Overall, 151 (70%) of the children with false-positive results scored below the 25th percentile on 1 or more diagnostic measures (the point at which most children have difficulty benefiting from typical classroom instruction) in contrast with 64 (29%) of the children with true-negative scores (odds ratio, 5.6; 95% CI, 3.73-8.49). Children with false-positive scores were also more likely to be nonwhite and to have parents who had not graduated from high school. Performance differences between children with true-negative scores and children with false-positive scores continued to be significant (P<.001) even after adjusting for sociodemographic differences between groups. Children overreferred for diagnostic testing by developmental screens perform substantially lower than children with true-negative scores on measures of intelligence, language, and academic achievement-the 3 best predictors of school success. These children also carry more psychosocial risk factors, such as limited parental education and minority status. Thus, children with false-positive screening results are an at-risk group for whom diagnostic testing may not be an unnecessary expense but rather a beneficial and needed service that can help focus intervention efforts. Although such testing will not indicate a need for special education placement, it can be useful in identifying children's needs for other programs known to improve language, cognitive, and academic skills, such as Head Start, Title I services, tutoring, private speech-language therapy, and quality day care.
Trade-offs in Cervical Cancer Prevention: Balancing Benefits and Risks
Stout, Natasha K.; Goldhaber-Fiebert, Jeremy D.; Ortendahl, Jesse D.; Goldie, Sue J.
2009-01-01
Background New screening and vaccination technologies will provide women with more options for cervical cancer prevention. Because the risk of cervical cancer diminishes with effective routine screening, women may wish to consider additional attributes, such as the likelihood of false-positive results and diagnostic procedures for mild abnormalities likely to resolve without intervention in their screening choices. Methods We used an empirically calibrated simulation model of cervical cancer in the United States to assess the benefits and potential risks associated with prevention strategies differing by primary screening test, triage test for abnormal results (cytologic testing, human papillomavirus [HPV] DNA test), and screening frequency. Outcomes included colposcopy referrals, cervical intraepithelial neoplasia (CIN) types 1 and 2 or 3, lifetime cancer risk, and quality-adjusted life expectancy. Results Across strategies, colposcopy referrals and diagnostic workups varied 3-fold, although diagnostic rates of CIN 2 or 3 were similar and 95% of positive screening test results were for mild abnormalities likely to resolve on their own. For a representative group of a thousand 20-year-old women undergoing triennial screening for 10 years, we expect 1038 colposcopy referrals (7 CIN 2 or 3 diagnoses) from combined cytologic and HPV DNA testing and fewer than 200 referrals (6–7 CIN 2 or 3 diagnoses) for strategies that use triage testing. Similarly, for a thousand 40-year-old women, combined cytologic and HPV DNA testing led to 489 referrals (9 CIN 2 or 3), whereas alternative strategies resulted in fewer than 150 referrals (7–8 CIN 2 or 3). Using cytologic testing followed by triage testing in younger women minimizes both diagnostic workups and positive HPV test results, whereas in older women diagnostic workups are minimized with HPV DNA testing followed by cytologic triage testing. Conclusions Clinically relevant information highlighting trade-offs among cervical cancer prevention strategies allows for inclusion of personal preferences into women’s decision making about screening and provides additional dimensions to the construction of clinical guidelines. PMID:18809815
Programmatic cost evaluation of nontargeted opt-out rapid HIV screening in the emergency department.
Haukoos, Jason S; Campbell, Jonathan D; Conroy, Amy A; Hopkins, Emily; Bucossi, Meggan M; Sasson, Comilla; Al-Tayyib, Alia A; Thrun, Mark W
2013-01-01
The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%-0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%-4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED.
Werner, Simone; Krause, Friedemann; Rolny, Vinzent; Strobl, Matthias; Morgenstern, David; Datz, Christian; Chen, Hongda; Brenner, Hermann
2016-04-01
In initial studies that included colorectal cancer patients undergoing diagnostic colonoscopy, we had identified a serum marker combination able to detect colorectal cancer with similar diagnostic performance as fecal immunochemical test (FIT). In this study, we aimed to validate the results in participants of a large colorectal cancer screening study conducted in the average-risk, asymptomatic screening population. We tested serum samples from 1,200 controls, 420 advanced adenoma patients, 4 carcinoma in situ patients, and 36 colorectal cancer patients with a 5-marker blood test [carcinoembryonic antigen (CEA)+anti-p53+osteopontin+seprase+ferritin]. The diagnostic performance of individual markers and marker combinations was assessed and compared with stool test results. AUCs for the detection of colorectal cancer and advanced adenomas with the 5-marker blood test were 0.78 [95% confidence interval (CI), 0.68-0.87] and 0.56 (95% CI, 0.53-0.59), respectively, which now is comparable with guaiac-based fecal occult blood test (gFOBT) but inferior to FIT. With cutoffs yielding specificities of 80%, 90%, and 95%, the sensitivities for the detection of colorectal cancer were 64%, 50%, and 42%, and early-stage cancers were detected as well as late-stage cancers. For osteopontin, seprase, and ferritin, the diagnostic performance in the screening setting was reduced compared with previous studies in diagnostic settings while CEA and anti-p53 showed similar diagnostic performance in both settings. Performance of the 5-marker blood test under screening conditions is inferior to FIT even though it is still comparable with the performance of gFOBT. CEA and anti-p53 could contribute to the development of a multiple marker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.
Code of Federal Regulations, 2012 CFR
2012-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2013 CFR
2013-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2014 CFR
2014-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2010 CFR
2010-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
Code of Federal Regulations, 2011 CFR
2011-01-01
... ruminant test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... for ruminants and for ruminant test specimens for diagnostic purposes; and reservation fees for space...) For ruminants and ruminant test specimens for diagnostic screening purposes intended for importation...
[Staged oncological screening with TG test].
Bakhlaev, I E; Ageenko, A I; Rolik, I S
2006-01-01
The authors present their analysis of screening methods used for early diagnostics of cancer of various localization and for detection of high-risk individuals. They offer a program of step-by-step screening that makes it possible to cover more population with prophylactic examination and to reduce the need for special examination methods. TG-test is a universal and the most informative blastomatous process indicator at any stage, including the preclinical one. The practical screening results double the revealing rate of oncopathology and allow for three-fold reduction in the diagnostic costs compared with standard methods of cancer diagnostics. The medical efficiency of the oncological screening is high; in one third of the examined patients a tumor is diagnosed at the preclinical stage.
Efficient strategies to find diagnostic test accuracy studies in kidney journals.
Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C
2015-08-01
Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.
Cumulative Incidence of False-Positive Results in Repeated, Multimodal Cancer Screening
Croswell, Jennifer Miller; Kramer, Barnett S.; Kreimer, Aimee R.; Prorok, Phil C.; Xu, Jian-Lun; Baker, Stuart G.; Fagerstrom, Richard; Riley, Thomas L.; Clapp, Jonathan D.; Berg, Christine D.; Gohagan, John K.; Andriole, Gerald L.; Chia, David; Church, Timothy R.; Crawford, E. David; Fouad, Mona N.; Gelmann, Edward P.; Lamerato, Lois; Reding, Douglas J.; Schoen, Robert E.
2009-01-01
PURPOSE Multiple cancer screening tests have been advocated for the general population; however, clinicians and patients are not always well-informed of screening burdens. We sought to determine the cumulative risk of a false-positive screening result and the resulting risk of a diagnostic procedure for an individual participating in a multimodal cancer screening program. METHODS Data were analyzed from the intervention arm of the ongoing Prostate, Lung, Colorectal, and Ovarian (PLCO) Cancer Screening Trial, a randomized controlled trial to determine the effects of prostate, lung, colorectal, and ovarian cancer screening on disease-specific mortality. The 68,436 participants, aged 55 to 74 years, were randomized to screening or usual care. Women received serial serum tests to detect cancer antigen 125 (CA-125), transvaginal sonograms, posteroanterior-view chest radiographs, and flexible sigmoidoscopies. Men received serial chest radiographs, flexible sigmoidoscopies, digital rectal examinations, and serum prostate-specific antigen tests. Fourteen screening examinations for each sex were possible during the 3-year screening period. RESULTS After 14 tests, the cumulative risk of having at least 1 false-positive screening test is 60.4% (95% CI, 59.8%–61.0%) for men, and 48.8% (95% CI, 48.1%–49.4%) for women. The cumulative risk after 14 tests of undergoing an invasive diagnostic procedure prompted by a false-positive test is 28.5% (CI, 27.8%–29.3%) for men and 22.1% (95% CI, 21.4%–22.7%) for women. CONCLUSIONS For an individual in a multimodal cancer screening trial, the risk of a false-positive finding is about 50% or greater by the 14th test. Physicians should educate patients about the likelihood of false positives and resulting diagnostic interventions when counseling about cancer screening. PMID:19433838
Shapiro, Adrienne E; Hong, Ting; Govere, Sabina; Thulare, Hilary; Moosa, Mahomed-Yunus; Dorasamy, Afton; Wallis, Carole L; Celum, Connie L; Grosset, Jacques; Drain, Paul K
2018-05-28
There is an urgent need for more accurate screening tests for tuberculosis(TB). We assessed the diagnostic accuracy of C-reactive protein (CRP) as a screening test for active TB in HIV-infected ambulatory adults. CRP levels were measured in blood collected at the time of HIV testing.Diagnostic accuracy of CRP for pulmonary TB was calculated (reference standard: TB culture), compared to the WHO 4-symptom screen, consisting of cough, fever, night sweats, and weight loss. Diagnostic accuracy was also calculated for CRP in a larger cohort of HIV-infected adults with a positive symptom screen (reference standard: clinical or microbiological TB). Among 425 HIV-infected outpatients systematically tested for pulmonary TB, TB culture was positive in 42 (10%), 279 (66%) had at least one TB-related symptom and 197 (46%) had a CRP >5 mg/L. The sensitivity of CRP and the TB symptom screen to detect TB was the same (90.5%; 95%CI 77.4-97.3) but specificity of CRP was higher than for the TB symptom screen (58.5% vs. 37.1%, p<0.001). Of persons with no symptoms and normal CRP, 99 (98%) had no TB. In another cohort of 749 patients presenting with at least one TB-related symptom and clinically evaluated, CRP had a sensitivity of 98.7% and specificity of 48.3%. In HIV-infected outpatients, CRP was as sensitive but substantially more specific than TB symptom screening. Use of CRP as a screening tool to exclude active TB could identify the same number of HIV-associated TB cases, but reduce the use of diagnostic sputum testing in TB-endemic regions.
Programmatic Cost Evaluation of Nontargeted Opt-Out Rapid HIV Screening in the Emergency Department
Haukoos, Jason S.; Campbell, Jonathan D.; Conroy, Amy A.; Hopkins, Emily; Bucossi, Meggan M.; Sasson, Comilla; Al-Tayyib, Alia A.; Thrun, Mark W.
2013-01-01
Background The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. Methods This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. Results During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%–0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%–4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Conclusions Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED. PMID:24391706
Matías-Guiu, Jordi A; Valles-Salgado, María; Rognoni, Teresa; Hamre-Gil, Frank; Moreno-Ramos, Teresa; Matías-Guiu, Jorge
2017-01-01
Our aim was to evaluate and compare the diagnostic properties of 5 screening tests for the diagnosis of mild Alzheimer disease (AD). We conducted a prospective and cross-sectional study of 92 patients with mild AD and of 68 healthy controls from our Department of Neurology. The diagnostic properties of the following tests were compared: Mini-Mental State Examination (MMSE), Addenbrooke's Cognitive Examination III (ACE-III), Memory Impairment Screen (MIS), Montreal Cognitive Assessment (MoCA), and Rowland Universal Dementia Assessment Scale (RUDAS). All tests yielded high diagnostic accuracy, with the ACE-III achieving the best diagnostic properties. The area under the curve was 0.897 for the ACE-III, 0.889 for the RUDAS, 0.874 for the MMSE, 0.866 for the MIS, and 0.856 for the MoCA. The Mini-ACE score from the ACE-III showed the highest diagnostic capacity (area under the curve 0.939). Memory scores of the ACE-III and of the RUDAS showed a better diagnostic accuracy than those of the MMSE and of the MoCA. All tests, especially the ACE-III, conveyed a higher diagnostic accuracy in patients with full primary education than in the less educated group. Implementing normative data improved the diagnostic accuracy of the ACE-III but not that of the other tests. The ACE-III achieved the highest diagnostic accuracy. This better discrimination was more evident in the more educated group. © 2017 S. Karger AG, Basel.
Appropriate use of screening and diagnostic tests to foster high-value, cost-conscious care.
Qaseem, Amir; Alguire, Patrick; Dallas, Paul; Feinberg, Lawrence E; Fitzgerald, Faith T; Horwitch, Carrie; Humphrey, Linda; LeBlond, Richard; Moyer, Darilyn; Wiese, Jeffrey G; Weinberger, Steven
2012-01-17
Unsustainable rising health care costs in the United States have made reducing costs while maintaining high-quality health care a national priority. The overuse of some screening and diagnostic tests is an important component of unnecessary health care costs. More judicious use of such tests will improve quality and reflect responsible awareness of costs. Efforts to control expenditures should focus not only on benefits, harms, and costs but on the value of diagnostic tests-meaning an assessment of whether a test provides health benefits that are worth its costs or harms. To begin to identify ways that practicing clinicians can contribute to the delivery of high-value, cost-conscious health care, the American College of Physicians convened a workgroup of physicians to identify, using a consensus-based process, common clinical situations in which screening and diagnostic tests are used in ways that do not reflect high-value care. The intent of this exercise is to promote thoughtful discussions about these tests and other health care interventions to promote high-value, cost-conscious care.
An Iconic Comparison of Photographs and the Live Television Screen in Visual Diagnostic Ability.
ERIC Educational Resources Information Center
Hofer, Jarrel
This study focused on five major activities: (1) developing an achievement test to measure visual diagnostic ability of television service technicians, (2) assessing the independence of the dimension of visual diagnostic ability, (3) comparing the iconic equivalence of photographs with motion cues and live screen presentations of defective…
Rice, Danielle B; Kloda, Lorie A; Shrier, Ian; Thombs, Brett D
2016-08-01
Meta-analyses that are conducted rigorously and reported completely and transparently can provide accurate evidence to inform the best possible healthcare decisions. Guideline makers have raised concerns about the utility of existing evidence on the diagnostic accuracy of depression screening tools. The objective of our study was to evaluate the transparency and completeness of reporting in meta-analyses of the diagnostic accuracy of depression screening tools using the PRISMA tool adapted for diagnostic test accuracy meta-analyses. We searched MEDLINE and PsycINFO from January 1, 2005 through March 13, 2016 for recent meta-analyses in any language on the diagnostic accuracy of depression screening tools. Two reviewers independently assessed the transparency in reporting using the PRISMA tool with appropriate adaptations made for studies of diagnostic test accuracy. We identified 21 eligible meta-analyses. Twelve of 21 meta-analyses complied with at least 50% of adapted PRISMA items. Of 30 adapted PRISMA items, 11 were fulfilled by ≥80% of included meta-analyses, 3 by 50-79% of meta-analyses, 7 by 25-45% of meta-analyses, and 9 by <25%. On average, post-PRISMA meta-analyses complied with 17 of 30 items compared to 13 of 30 items pre-PRISMA. Deficiencies in the transparency of reporting in meta-analyses of the diagnostic test accuracy of depression screening tools of meta-analyses were identified. Authors, reviewers, and editors should adhere to the PRISMA statement to improve the reporting of meta-analyses of the diagnostic accuracy of depression screening tools. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Terry, Nicole P.; Petscher, Yaacov; Rhodes, Katherine T.
2017-01-01
The purpose of this study was to extend a previous investigation of the psychometrics of the "Diagnostic Evaluation of Language Variation-Screening Test" (DELV-S) to include pre-kindergarten children (primarily African American and from low-income households). The previous study (Petscher, Connor, & Al Otaiba, 2012) included a…
Brown, Jeremy P; Wooldrage, Kate; Wright, Suzanne; Nickerson, Claire; Cross, Amanda J; Atkin, Wendy S
2018-06-01
Objectives The English Bowel Cancer Screening Programme offers biennial guaiac faecal occult blood test (gFOBT) screening to 60-74-year-olds. Participants with positive results are referred for follow-up, but many do not have significant findings. If they remain age eligible, these individuals are reinvited for gFOBT screening. We evaluated the performance of repeat screening in this group. Methods We analysed data on programme participants reinvited to gFOBT screening after either previous negative gFOBT ( n = 327,542), or positive gFOBT followed by a diagnostic investigation negative for colorectal cancer (CRC) or adenomas requiring surveillance ( n = 42,280). Outcomes calculated were uptake, test positivity, yield of CRC, and positive predictive value (PPV) of gFOBT for CRC. Results For participants with a previous negative gFOBT, uptake in the subsequent screening round was 87.5%, positivity was 1.3%, yield of CRC was 0.112% of those adequately screened, and the PPV of gFOBT for CRC was 9.1%. After a positive gFOBT and a negative diagnostic investigation, uptake in the repeat screening round was 82.6%, positivity was 11.3%, CRC yield was 0.172% of participants adequately screened, and the PPV of gFOBT for CRC was 1.7%. Conclusion With high positivity and low PPV for CRC, the suitability of routine repeat gFOBT screening in two years among individuals with a previous positive test and a negative diagnostic examination needs to be carefully considered.
System theory in medical diagnostic devices: an overview.
Baura, Gail D
2006-01-01
Medical diagnostics refers to testing conducted either in vitro or in vivo to provide critical health care information for risk assessment, early diagnosis, treatment, or disease management. Typical in vivo diagnostic tests include the computed tomography scan, magnetic resonance imaging, and blood pressure screening. Typical in vitro diagnostic tests include cholesterol, Papanicolaou smear, and conventional glucose monitoring tests. Historically, devices associated with both types of diagnostics have used heuristic curve fitting during signal analysis. However, since the early 1990s, a few enterprising engineers and physicians have used system theory to improve their core processing for feature detection and system identification. Current applications include automated Pap smear screening for detection of cervical cancer and diagnosis of Alzheimer's disease. Future applications, such as disease prediction before symptom onset and drug treatment customization, have been catalyzed by the Human Genome Project.
[Variations in the diagnostic confirmation process between breast cancer mass screening units].
Natal, Carmen; Fernández-Somoano, Ana; Torá-Rocamora, Isabel; Tardón, Adonina; Castells, Xavier
2016-01-01
To analyse variations in the diagnostic confirmation process between screening units, variations in the outcome of each episode and the relationship between the use of the different diagnostic confirmation tests and the lesion detection rate. Observational study of variability of the standardised use of diagnostic and lesion detection tests in 34 breast cancer mass screening units participating in early-detection programmes in three Spanish regions from 2002-2011. The diagnostic test variation ratio in percentiles 25-75 ranged from 1.68 (further appointments) to 3.39 (fine-needle aspiration). The variation ratio in detection rates of benign lesions, ductal carcinoma in situ and invasive cancer were 2.79, 1.99 and 1.36, respectively. A positive relationship between rates of testing and detection rates was found with fine-needle aspiration-benign lesions (R(2): 0.53), fine-needle aspiration-invasive carcinoma (R(2): 0 28), core biopsy-benign lesions (R(2): 0.64), core biopsy-ductal carcinoma in situ (R(2): 0.61) and core biopsy-invasive carcinoma (R(2): 0.48). Variation in the use of invasive tests between the breast cancer screening units participating in early-detection programmes was found to be significantly higher than variations in lesion detection. Units which conducted more fine-needle aspiration tests had higher benign lesion detection rates, while units that conducted more core biopsies detected more benign lesions and cancer. Copyright © 2016 SESPAS. Published by Elsevier Espana. All rights reserved.
Diagnostic Evasion of Highly-Resistant Microorganisms: A Critical Factor in Nosocomial Outbreaks.
Zhou, Xuewei; Friedrich, Alexander W; Bathoorn, Erik
2017-01-01
Highly resistant microorganisms (HRMOs) may evade screening strategies used in routine diagnostics. Bacteria that have evolved to evade diagnostic tests may have a selective advantage in the nosocomial environment. Evasion of resistance detection can result from the following mechanisms: low-level expression of resistance genes not resulting in detectable resistance, slow growing variants, mimicry of wild-type-resistance, and resistance mechanisms that are only detected if induced by antibiotic pressure. We reviewed reports on hospital outbreaks in the Netherlands over the past 5 years. Remarkably, many outbreaks including major nation-wide outbreaks were caused by microorganisms able to evade resistance detection by diagnostic screening tests. We describe various examples of diagnostic evasion by several HRMOs and discuss this in a broad and international perspective. The epidemiology of hospital-associated bacteria may strongly be affected by diagnostic screening strategies. This may result in an increasing reservoir of resistance genes in hospital populations that is unnoticed. The resistance elements may horizontally transfer to hosts with systems for high-level expression, resulting in a clinically significant resistance problem. We advise to communicate the identification of HRMOs that evade diagnostics within national and regional networks. Such signaling networks may prevent inter-hospital outbreaks, and allow collaborative development of adapted diagnostic tests.
Pre- and post-test genetic counseling for chromosomal and Mendelian disorders.
Fonda Allen, Jill; Stoll, Katie; Bernhardt, Barbara A
2016-02-01
Genetic carrier screening, prenatal screening for aneuploidy, and prenatal diagnostic testing have expanded dramatically over the past 2 decades. Driven in part by powerful market forces, new complex testing modalities have become available after limited clinical research. The responsibility for offering these tests lies primarily on the obstetrical care provider and has become more burdensome as the number of testing options expands. Genetic testing in pregnancy is optional, and decisions about undergoing tests, as well as follow-up testing, should be informed and based on individual patients' values and needs. Careful pre- and post-test counseling is central to supporting informed decision-making. This article explores three areas of technical expansion in genetic testing: expanded carrier screening, non-invasive prenatal screening for fetal aneuploidies using cell-free DNA, and diagnostic testing using fetal chromosomal microarray testing, and provides insights aimed at enabling the obstetrical practitioner to better support patients considering these tests. Copyright © 2016 Elsevier Inc. All rights reserved.
Matsuda, Izumi; Ogawa, Tokihiro; Tsuneoka, Michiko; Verschuere, Bruno
2015-03-01
The concealed information test (CIT) can be used to assess whether an individual possesses crime-related information. However, its discrimination performance has room for improvement. We examined whether screening out participants who do not respond distinctively on a pretest improves the diagnosticity of a mock-crime CIT. Before conducting the CIT, we gave a pretest to 152 participants, 80 of whom were assigned as guilty. Pretest screening significantly improved the diagnostic value of the mock-crime CIT; however, it also led to a substantial number of undiagnosed participants (33.6%). Pretest screening holds promise, but its application would benefit from dedicated measures for screening out participants. © 2014 Society for Psychophysiological Research.
Toscano, Cristiana M; Duncan, Bruce B; Mengue, Sotero S; Polanczyk, Carísi Anne; Nucci, Luciana B; Costa e Forti, Adriana; Fonseca, Cláudio D; Schmidt, Maria Inês
2008-01-01
Background In 2001 Brazilian citizens aged 40 or older were invited to participate in a nationwide population screening program for diabetes. Capillary glucose screening tests and procedures for diagnostic confirmation were offered through the national healthcare system, diagnostic priority being given according to the severity of screening results. The objective of this study is to evaluate the initial impact of the program. Methods Positive testing was defined by a fasting capillary glucose ≥ 100 mg/dL or casual glucose ≥ 140 mg/dL. All test results were tabulated locally and aggregate data by gender and clinical categories were sent to the Ministry of Health. To analyze individual characteristics of screening tests performed, a stratified random sample of 90,106 tests was drawn. To describe the actions taken for positive screenees, a random sub-sample of 4,906 positive screenees was actively followed up through home interviews. Main outcome measures considered were the number of diabetes cases diagnosed and cost per case detected and incorporated into healthcare. Results Of 22,069,905 screening tests performed, we estimate that 3,417,106 (95% CI 3.1 – 3.7 million) were positive and that 346,168 (290,454 – 401,852) new cases were diagnosed (10.1% of positives), 319,157 (92.2%) of these being incorporated into healthcare. The number of screening tests needed to detect one case of diabetes was 64. As many cases of untreated but previously known diabetes were also linked to healthcare providers during the Campaign, the estimated number needed screen to incorporate one case into the healthcare system was 58. Total screening and diagnostic costs were US$ 26.19 million, the cost per diabetes case diagnosed being US$ 76. Results were especially sensitive to proportion of individuals returning for diagnostic confirmation. Conclusion This nationwide population-based screening program, conducted through primary healthcare services, demonstrates the feasibility, within the context of an organized national healthcare system, of screening campaigns for chronic diseases. Although overall costs were significant, cost per new case diagnosed was lower than previously reported. However, cost-effectiveness analysis based on more clinically significant outcomes needs to be conducted before this screening approach can be recommended in other settings. PMID:18808662
Chiolero, Arnaud; Paccaud, Fred; Aujesky, Drahomir; Santschi, Valérie; Rodondi, Nicolas
2015-01-01
Overdiagnosis is the diagnosis of an abnormality that is not associated with a substantial health hazard and that patients have no benefit to be aware of. It is neither a misdiagnosis (diagnostic error), nor a false positive result (positive test in the absence of a real abnormality). It mainly results from screening, use of increasingly sensitive diagnostic tests, incidental findings on routine examinations, and widening diagnostic criteria to define a condition requiring an intervention. The blurring boundaries between risk and disease, physicians' fear of missing a diagnosis and patients' need for reassurance are further causes of overdiagnosis. Overdiagnosis often implies procedures to confirm or exclude the presence of the condition and is by definition associated with useless treatments and interventions, generating harm and costs without any benefit. Overdiagnosis also diverts healthcare professionals from caring about other health issues. Preventing overdiagnosis requires increasing awareness of healthcare professionals and patients about its occurrence, the avoidance of unnecessary and untargeted diagnostic tests, and the avoidance of screening without demonstrated benefits. Furthermore, accounting systematically for the harms and benefits of screening and diagnostic tests and determining risk factor thresholds based on the expected absolute risk reduction would also help prevent overdiagnosis.
HIV Testing in the United States
... health facilities ;” May 2007. ← Return to text FDA Consumer Information, “Fourth Generation HIV Diagnostic Test Approved, permitting ... HIV): Screening; ” April 2013. ← Return to text FDA Consumer Information, “First rapid diagnostic test to detect both ...
Screening strategies for atrial fibrillation: a systematic review and cost-effectiveness analysis.
Welton, Nicky J; McAleenan, Alexandra; Thom, Howard Hz; Davies, Philippa; Hollingworth, Will; Higgins, Julian Pt; Okoli, George; Sterne, Jonathan Ac; Feder, Gene; Eaton, Diane; Hingorani, Aroon; Fawsitt, Christopher; Lobban, Trudie; Bryden, Peter; Richards, Alison; Sofat, Reecha
2017-05-01
Atrial fibrillation (AF) is a common cardiac arrhythmia that increases the risk of thromboembolic events. Anticoagulation therapy to prevent AF-related stroke has been shown to be cost-effective. A national screening programme for AF may prevent AF-related events, but would involve a substantial investment of NHS resources. To conduct a systematic review of the diagnostic test accuracy (DTA) of screening tests for AF, update a systematic review of comparative studies evaluating screening strategies for AF, develop an economic model to compare the cost-effectiveness of different screening strategies and review observational studies of AF screening to provide inputs to the model. Systematic review, meta-analysis and cost-effectiveness analysis. Primary care. Adults. Screening strategies, defined by screening test, age at initial and final screens, screening interval and format of screening {systematic opportunistic screening [individuals offered screening if they consult with their general practitioner (GP)] or systematic population screening (when all eligible individuals are invited to screening)}. Sensitivity, specificity and diagnostic odds ratios; the odds ratio of detecting new AF cases compared with no screening; and the mean incremental net benefit compared with no screening. Two reviewers screened the search results, extracted data and assessed the risk of bias. A DTA meta-analysis was perfomed, and a decision tree and Markov model was used to evaluate the cost-effectiveness of the screening strategies. Diagnostic test accuracy depended on the screening test and how it was interpreted. In general, the screening tests identified in our review had high sensitivity (> 0.9). Systematic population and systematic opportunistic screening strategies were found to be similarly effective, with an estimated 170 individuals needed to be screened to detect one additional AF case compared with no screening. Systematic opportunistic screening was more likely to be cost-effective than systematic population screening, as long as the uptake of opportunistic screening observed in randomised controlled trials translates to practice. Modified blood pressure monitors, photoplethysmography or nurse pulse palpation were more likely to be cost-effective than other screening tests. A screening strategy with an initial screening age of 65 years and repeated screens every 5 years until age 80 years was likely to be cost-effective, provided that compliance with treatment does not decline with increasing age. A national screening programme for AF is likely to represent a cost-effective use of resources. Systematic opportunistic screening is more likely to be cost-effective than systematic population screening. Nurse pulse palpation or modified blood pressure monitors would be appropriate screening tests, with confirmation by diagnostic 12-lead electrocardiography interpreted by a trained GP, with referral to a specialist in the case of an unclear diagnosis. Implementation strategies to operationalise uptake of systematic opportunistic screening in primary care should accompany any screening recommendations. Many inputs for the economic model relied on a single trial [the Screening for Atrial Fibrillation in the Elderly (SAFE) study] and DTA results were based on a few studies at high risk of bias/of low applicability. Comparative studies measuring long-term outcomes of screening strategies and DTA studies for new, emerging technologies and to replicate the results for photoplethysmography and GP interpretation of 12-lead electrocardiography in a screening population. This study is registered as PROSPERO CRD42014013739. The National Institute for Health Research Health Technology Assessment programme.
Measuring the quality-of-life effects of diagnostic and screening tests.
Swan, J Shannon; Miksad, Rebecca A
2009-08-01
Health-related quality of life (HRQL) is a central concept for understanding the outcomes of medical care. When used in cost-effectiveness analysis, HRQL is typically measured for conditions persisting over long time frames (years), and quality-adjusted life year (QALY) values are generated. Consequently, years are the basic unit of time for cost-effectiveness analysis results: dollars spent per QALY gained. However, shorter term components of health care may also affect HRQL, and there is increased interest in measuring and accounting for these events. In radiology, the short-term HRQL effects of screening and diagnostic testing may affect a test's cost-effectiveness, even though they may only last for days. The unique challenge in radiology HRQL assessment is to realistically tap into the testing and screening experience while remaining consistent with QALY theory. The authors review HRQL assessment and highlight methods developed to specifically address the short-term effects of radiologic screening and testing.
Raich, Peter C; Whitley, Elizabeth M; Thorland, William; Valverde, Patricia; Fairclough, Diane
2012-10-01
Barriers to timely resolution of abnormal cancer screening tests add to cancer health disparities among low-income, uninsured, and minority populations. We conducted a randomized trial to evaluate the impact of lay patient navigators on time to resolution and completion of follow-up testing among patients with abnormal screening tests in a medically underserved patient population. Denver Health, the safety-net health care system serving Denver, is one of 10 performance sites participating in the Patient Navigation Research Program. Of 993 eligible subjects with abnormal screening tests randomized to navigation and no-navigation (control) arms and analyzed, 628 had abnormal breast screens (66 abnormal clinical breast examinations, 304 BIRADS 0, 200 BIRADS 3, 58 BIRADS 4 or 5) whereas 235 had abnormal colorectal and 130 had abnormal prostate screens. Time to resolution was significantly shorter in the navigated group (stratified log rank test, P < 0.001). Patient navigation improved diagnostic resolution for patients presenting with mammographic BIRADS 3 (P = 0.0003) and BIRADS 0 (P = 0.09), but not BIRADS 4/5 or abnormal breast examinations. Navigation shortened the time for both colorectal (P = 0.0017) and prostate screening resolution (P = 0.06). Participant demographics included 72% minority, 49% with annual household income less than $10,000, and 36% uninsured. Patient navigation positively impacts time to resolution of abnormal screening tests for breast, colorectal, and prostate cancers in a medically underserved population. By shortening the time to and increasing the proportion of patients with diagnostic resolution patient navigation could reduce disparities in stage at diagnosis and improve cancer outcomes. 2012 AACR
Senkomago, Virginia; Royalty, Janet; Miller, Jacqueline W; Buenconsejo-Lum, Lee E; Benard, Vicki B; Saraiya, Mona
2017-10-01
Cervical cancer incidence in the US-Affiliated Pacific Islands (USAPIs) is double that of the US mainland. American Samoa, Commonwealth of Northern Mariana Islands (CNMI), Guam and the Republic of Palau receive funding from the Centers for Disease Control (CDC) National Breast and Cervical Cancer Early Detection Program (NBCCEDP) to implement cervical cancer screening to low-income, uninsured or under insured women. The USAPI grantees report data on screening and follow-up activities to the CDC. We examined cervical cancer screening and follow-up data from the NBCCEDP programs in the four USAPIs from 2007 to 2015. We summarized screening done by Papanicolaou (Pap) and oncogenic human papillomavirus (HPV) tests, follow-up and diagnostic tests provided, and histology results observed. A total of 22,249 Pap tests were conducted in 14,206 women in the four USAPIs programs from 2007-2015. The overall percentages of abnormal Pap results (low-grade squamous intraepithelial lesions or worse) was 2.4% for first program screens and 1.8% for subsequent program screens. Histology results showed a high proportion of cervical intraepithelial neoplasia grade 2 or worse (57%) among women with precancers and cancers. Roughly one-third (32%) of Pap test results warranting follow-up had no data recorded on diagnostic tests or follow-up done. This is the first report of cervical cancer screening and outcomes of women served in the USAPI through the NBCCEDP with similar results for abnormal Pap tests, but higher proportion of precancers and cancers, when compared to national NBCCEDP data. The USAPI face significant challenges in implementing cervical cancer screening, particularly in providing and recording data on diagnostic tests and follow-up. The screening programs in the USAPI should further examine specific barriers to follow-up of women with abnormal Pap results and possible solutions to address them. Published by Elsevier Ltd.
Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka
2016-02-01
To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.
Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka
2016-01-01
Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612
Further statistics in dentistry, Part 5: Diagnostic tests for oral conditions.
Petrie, A; Bulman, J S; Osborn, J F
2002-12-07
A diagnostic test is a simple test, sometimes based on a clinical measurement, which is used when the gold-standard test providing a definitive diagnosis of a given condition is too expensive, invasive or time-consuming to perform. The diagnostic test can be used to diagnose a dental condition in an individual patient or as a screening device in a population of apparently healthy individuals.
[A new system of testing visual performance based on the cylindrical lens screen].
Doege, E; Krause, O
1983-09-01
Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.
Whitley, Elizabeth M; Raich, Peter C; Dudley, Donald J; Freund, Karen M; Paskett, Electra D; Patierno, Steven R; Simon, Melissa; Warren-Mears, Victoria; Snyder, Frederick R
2016-01-01
Background Whether patient navigation improves outcomes in patients with comorbidities is unknown. Study aims were to determine the effect of comorbidities on time to diagnostic resolution following an abnormal cancer screening test, and to examine for patients with comorbidities, if patient navigation improves timeliness and likelihood of diagnostic resolution compared to patients without navigation. Methods A secondary analysis from the Patient Navigation Research Program sites that collected comorbidity data using the Charlson Comorbidity Index (CCI) was conducted. Participants were 6,349 patients with abnormal breast, cervical, colon or prostate cancer screening tests between 2007 and 2011. The intervention was patient navigation or usual care. CCI data were highly skewed across projects and cancer sites and were categorized as 0, no comorbidities identified, CCI score of 0 (76% of cases); 1, CCI score of 1 (16% of cases); or 2, CCI score of ≥2 (8% of cases). A separate adjusted hazards ratio for each site and cancer type was obtained, and then pooled using meta-analysis random effects methodology. Results Having a CCI score of ≥2 delayed the time to diagnostic resolution following an abnormal cancer screening test compared with those with fewer than one comorbidity. Patient Navigation reduced delays in diagnostic resolution with the greatest benefit seen in those with a CCI score of ≥2. Conclusions Persons with a CCI score of ≥2 experienced significant delays in timely diagnostic care compared to patients without comorbidities. Patient navigation was effective in reducing delays in diagnostic resolution among those with CCI scores > 1. PMID:27648520
Test of memory malingering (TOMM) trial 1 as a screening measure for insufficient effort.
O'Bryant, Sid E; Engel, Lisa R; Kleiner, Jennifer S; Vasterling, Jennifer J; Black, F William
2007-05-01
The identification of insufficient effort is critical to neuropsychological evaluation, and several existing instruments assess effort on neuropsychological tasks. Yet instruments designed to detect insufficient effort are underutilized in standard neuropsychological assessments, perhaps in part because they typically require significant administration time and are, therefore, not ideally suited to screening contexts. The Test of Memory Malingering (TOMM) is a commonly administered, well-validated symptom validity test. This study evaluates the utility of TOMM Trial 1 as a relatively brief screening measure of insufficient effort. Results suggest that TOMM Trial 1 demonstrates high diagnostic accuracy and is a viable option for screening insufficient effort. Diagnostic accuracy estimates are presented for a range of base rates. The need for more comprehensive SVT assessment in most clinical and forensic situation is discussed.
Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.
2010-01-01
Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614
Improved diagnostics of chronic inflammatory prostatitis.
Kulchavenya, E; Azizoff, A; Brizhatyuk, E; Khomyakov, V; Kholtobin, D; Breusoff, A; Naber, K G
2012-12-01
Prostatitis is a prevalent condition that encompasses a large array of clinical symptoms with significant impacts on men's life. The diagnosis and treatment of this disorder presents numerous challenges for urologists, most notably, a lack of specific and effective diagnostic methods. To improve the diagnostics the comparison of classic 4-glass test Meares and Stamey, 2-glass tests and 3-glass test was conducted in 177 men suspicious for chronic prostatitis. Four-glass test is uncomfortable both for patients and doctors, and leads to contamination of urine with prostatic secretion. Two-glass test is insufficiently effective too. Three-glass test (three urine specimens obtained from one continuous micturition stream) gives more adequate results and may be used for screening. Three-glass test as screening test with the option of an additional EPS investigation in those patients the final diagnosis of chronic prostatitis has to be confirmed is more convenient for patients and doctors than the standard M&S 4-glass test and "false-positive" (contaminated with EPS) midstream urine results are avoided thus improving discrimination of urethritis, cystitis and prostatitis. Therefore, we recommend the KE 3-glass test as a new standard for screening patients with signs and symptoms of chronic inflammatory prostatitis.
Cargnin, Sarah; Jommi, Claudio; Canonico, Pier Luigi; Genazzani, Armando A; Terrazzino, Salvatore
2014-05-01
To determine diagnostic accuracy of HLA-B*57:01 testing for prediction of abacavir-induced hypersensitivity and to quantify the clinical benefit of pretreatment screening through a meta-analytic review of published studies. A comprehensive search was performed up to June 2013. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. The pooled diagnostic estimates were calculated using a random effect model. Despite the presence of heterogeneity in sensitivity or specificity estimates, the pooled diagnostic odds ratio to detect abacavir-induced hypersensitivity on the basis of clinical criteria was 33.07 (95% CI: 22.33-48.97, I(2): 13.9%), while diagnostic odds ratio for detection of immunologically confirmed abacavir hypersensitivity was 1141 (95% CI: 409-3181, I(2): 0%). Pooled analysis of risk ratio showed that prospective HLA-B*57:01 testing significantly reduced the incidence of abacavir-induced hypersensitivity. This meta-analysis demonstrates an excellent diagnostic accuracy of HLA-B*57:01 testing to detect immunologically confirmed abacavir hypersensitivity and corroborates existing recommendations.
Fetal aneuploidy detection by maternal plasma DNA sequencing: a technology assessment.
Walsh, Judith M E; Goldberg, James D
2013-06-01
The American College of Obstetricians and Gynecologists currently recommends that all pregnant women be offered screening for chromosomal abnormalities, regardless of maternal age. Traditional screening tests have detection rates ranging from 85% to 90% and false-positive rates of 3% to 5%. A woman with an abnormal noninvasive test is offered a diagnostic test, but diagnostic tests are associated with a risk of pregnancy loss. Recently, analysis of cell-free fetal DNA (cffDNA) in maternal blood has been shown to have potential for the accurate detection of some of the common fetal autosomal aneuploidies. As part of a technology assessment for the California Technology Assessment Forum, we critically reviewed the evidence for the use of cffDNA as a prenatal screening test. We evaluated the evidence for its use as either a 'primary' or an 'advanced' screening test and for its use in screening for three different trisomies: 21, 18, and 13. We evaluated whether the use of cffDNA met established technology assessment criteria and established conclusions about evidence-based use of this new technology. © 2013 John Wiley & Sons, Ltd.
Investigation of the Lollipop Test as a Pre-Kindergarten Screening Instrument.
ERIC Educational Resources Information Center
Chew, Alex L.; Morris, John D.
1987-01-01
The validity of the Lollipop Test: A Diagnostic Screening Test of School Readiness was examined for 129 pre-kindergarten subjects using the Developmental Indicator for the Assessment of Learning as the criterion. Concurrent validity was demonstrated across the test batteries. The Lollipop Test appears to be an attractive alternative…
Tjalma, Wiebren A A
2017-03-01
Cervical cancer screening saves lives. Secondary prevention in cervical cancer screening relies on the results of primary cytology and/or HPV testing. However, primary screening with cytology has a low sensitivity, and HPV screening has a low specificity. This means that either cancers are missed, or women are over-treated. To improve performance outcomes, the concept of dual-stain cytology (CINtec ® PLUS Cytology test) has been introduced. In this approach, additional staining with p16/Ki-67 is performed in cases where cytology results are abnormal (LSIL or ASCUS) and/or HPV-positive. Another way to describe this approach might be "diagnostic" cytology. In order to assess the value of this "diagnostic cytology", a systematic literature review was conducted of dual-stain cytology performance across multiple studies until May 2016. In a Belgian screening population (women age 25-65 years), dual-stain cytology was significantly more sensitive (66%) and slightly less specific (-1.0%) than cytology. In the population referred to colposcopy or with abnormal cytology (ASCUS, LSIL), dual-staining showed a significantly higher increase in specificity, and a slightly lower sensitivity than HPV testing. Specificity gains resulted in fewer false positives and an increase in the number of correct referrals to colposcopy. Dual-staining with p16/Ki-67 cytology is an attractive biomarker approach for triage in cervical cancer screening. Copyright © 2017 Elsevier B.V. All rights reserved.
Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela
2015-05-15
Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.
Identification of Undiagnosed Inflammatory Arthritis in a Community Health-Fair Screen
Deane, Kevin D.; Striebich, Christopher C.; Goldstein, Barbara L.; Derber, Lezlie A.; Parish, Mark C.; Feser, Marie L.; Hamburger, Elaine M.; Brake, Stacey; Belz, Cindy; Goddard, James; Norris, Jill M.; Karlson, Elizabeth W.; Holers, V. Michael
2010-01-01
Purpose The primary goals of this study were: 1) to identify individuals with undiagnosed inflammatory arthritis (IA) and rheumatoid arthritis (RA) in a community health-fair screen, and 2) to establish in a health-fair setting the diagnostic accuracy of combinations of the Connective Tissue Disease Screening Questionnaire (CSQ) and autoantibody testing for IA. Methods Screening for IA/RA was performed at health-fair sites using a combination of CSQ, joint examination, rheumatoid factor (RF) and anti-cyclic citrullinated (anti-CCP) antibody testing. IA was defined as ≥1 swollen joint/s suggestive of synovitis on joint examination by a trained clinician. Results Six-hundred one subjects were screened; 51.0% participating because of joint symptoms (pain, stiffness, or swelling). Eighty-four subjects (14.0%) had ≥1 swollen joint/s designated as IA on joint examination. Of the 601 subjects screened, 9 (1.5%) had IA and met ≥4 of 7 American College of Rheumatology criteria for RA but had no prior diagnosis of RA, and 15 (2.5%) had IA and RF and/or anti-CCP positivity, suggesting early RA. The diagnostic accuracy of combinations of CSQ and autoantibody testing for the identification of IA yielded maximal sensitivity, specificity, positive and negative predictive values of 95.3%, 99.2%, 71.4%, and 97.7%, respectively. Conclusions Health-fair screening may be an effective approach for the identification of individuals with undiagnosed IA/RA. A combination of CSQ and autoantibody testing alone has clinically useful diagnostic accuracy for the detection of IA. Decisions regarding which methodology to use for future health-fair IA/RA screening will depend on goals of screening and funding. PMID:19950306
Whitley, Elizabeth M; Raich, Peter C; Dudley, Donald J; Freund, Karen M; Paskett, Electra D; Patierno, Steven R; Simon, Melissa; Warren-Mears, Victoria; Snyder, Frederick R
2017-01-01
Whether patient navigation improves outcomes for patients with comorbidities is unknown. The aims of this study were to determine the effect of comorbidities on the time to diagnostic resolution after an abnormal cancer screening test and to examine whether patient navigation improves the timeliness and likelihood of diagnostic resolution for patients with comorbidities in comparison with no navigation. A secondary analysis of comorbidity data collected by Patient Navigation Research Program sites using the Charlson Comorbidity Index (CCI) was conducted. The participants were 6,349 patients with abnormal breast, cervical, colon, or prostate cancer screening tests between 2007 and 2011. The intervention was patient navigation or usual care. The CCI data were highly skewed across projects and cancer sites, and the CCI scores were categorized as 0 (CCI score of 0 or no comorbidities identified; 76% of cases); 1 (CCI score of 1; 16% of cases), or 2 (CCI score ≥ 2; 8% of cases). Separate adjusted hazard ratios for each site and cancer type were obtained, and then they were pooled with a meta-analysis random effects methodology. Patients with a CCI score ≥ 2 had delayed diagnostic resolution after an abnormal cancer screening test in comparison with those with no comorbidities. Patient navigation reduced delays in diagnostic resolution, with the greatest benefits seen for those with a CCI score ≥ 2. Persons with a CCI score ≥ 2 experienced significant delays in timely diagnostic care in comparison with patients without comorbidities. Patient navigation was effective in reducing delays in diagnostic resolution among those with CCI scores > 1. Cancer 2017;123:312-318. © 2016 American Cancer Society. © 2016 American Cancer Society.
Wang, Li-Yun; Chen, Nien-I; Chen, Pin-Wen; Chiang, Shu-Chuan; Hwu, Wuh-Liang; Lee, Ni-Chung; Chien, Yin-Hsiu
2013-02-10
Tandem mass spectrometry (MS/MS) analysis is a powerful tool for newborn screening, and many rare inborn errors of metabolism are currently screened using MS/MS. However, the sensitivity of MS/MS screening for several inborn errors, including citrin deficiency (screened by citrulline level) and carnitine uptake defect (CUD, screened by free carnitine level), is not satisfactory. This study was conducted to determine whether a second-tier molecular test could improve the sensitivity of citrin deficiency and CUD detection without increasing the false-positive rate. Three mutations in the SLC25A13 gene (for citrin deficiency) and one mutation in the SLC22A5 gene (for CUD) were analyzed in newborns who demonstrated an inconclusive primary screening result (with levels between the screening and diagnostic cutoffs). The results revealed that 314 of 46 699 newborns received a second-tier test for citrin deficiency, and two patients were identified; 206 of 30 237 newborns received a second-tier testing for CUD, and one patient was identified. No patients were identified using the diagnostic cutoffs. Although the incidences for citrin deficiency (1:23 350) and CUD (1:30 000) detected by screening are still lower than the incidences calculated from the mutation carrier rates, the second-tier molecular test increases the sensitivity of newborn screening for citrin deficiency and CUD without increasing the false-positive rate. Utilizing a molecular second-tier test for citrin deficiency and carnitine transporter deficiency is feasible.
Kronman, Andrea C; Freund, Karen M; Heeren, Tim; Beaver, Kristine A; Flynn, Mary; Battaglia, Tracy A
2012-04-01
Delays in care after abnormal cancer screening contribute to disparities in cancer outcomes. Women with psychiatric disorders are less likely to receive cancer screening and may also have delays in diagnostic resolution after an abnormal screening test. To determine if depression and anxiety are associated with delays in resolution after abnormal mammograms and Pap tests in a vulnerable population of urban women. We conducted retrospective chart reviews of electronic medical records to identify women who had a diagnosis of depression or anxiety in the year prior to the abnormal mammogram or Pap test. We used time-to-event analysis to analyze the outcome of time to resolution after abnormal cancer screening, and Cox proportional hazards regression modeling to control for confounding. Women receiving care in six Boston-area community health centers 2004-2005: 523 with abnormal mammograms, 474 with abnormal Pap tests. Of the women with abnormal mammogram and pap tests, 19% and 16%, respectively, had co-morbid depression. There was no difference in time to diagnostic resolution between depressed and not-depressed women for those with abnormal mammograms (aHR = 0.9, 95 CI 0.7,1.1) or Pap tests (aHR = 0.9, 95 CI 0.7,1.3). An active diagnosis of depression and/or anxiety in the year prior to an abnormal mammogram or Pap test was not associated with a prolonged time to diagnostic resolution. Our findings imply that documented mood disorders do not identify an additional barrier to resolution after abnormal cancer screening in a vulnerable population of women.
Yamamoto, Kenyu; Yamazaki, Hideo; Kuroda, Chikazumi; Kubo, Tsugio; Oshima, Akira; Katsuda, Toshizo; Kuwano, Tadao; Takeda, Yoshihiro
2010-01-01
Background The use of high-density barium sulfate was recommended by the Japan Society of Gastroenterological Cancer Screening (JSGCS) in 2004. We evaluated the diagnostic validity of gastric cancer screening that used high-density barium sulfate. Methods The study subjects were 171 833 residents of Osaka, Japan who underwent gastric cancer screening tests at the Osaka Cancer Prevention and Detection Center during the period from 1 January 2000 through 31 December 2001. Screening was conducted using either high-density barium sulfate (n = 48 336) or moderate-density barium sulfate (n = 123 497). The subjects were followed up and their medical records were linked to those of the Osaka Cancer Registry through 31 December 2002. The results of follow-up during 1 year were defined as the gold standard, and test performance values were calculated. Results The sensitivity and specificity of the screening test using moderate-density barium sulfate were 92.3% and 91.0%, respectively, while the sensitivity and specificity of the high-density barium test were 91.8% and 91.4%, respectively. The results of area under receiver-operating-characteristic (ROC) curve analysis revealed no significant difference between the 2 screening tests. Conclusions Screening tests using high- and moderate-density barium sulfate had similar validity, as determined by sensitivity, specificity, and ROC curve analysis. PMID:20551581
Renshaw, Richard; Ellis, Katrina; Jacobs, Patricia; Morris, Joan
2013-10-01
Pregnant women who receive a high screening risk result for Down, Edwards or Patau syndrome are offered diagnostic tests that carry a procedure-related risk of miscarriage. This study quantifies the improvement in the screening tests by calculating the number of women who had such tests per syndrome diagnosis from 1991 to 2010. Routinely stored data on prenatal chorionic villus sampling (CVS) and amniocentesis samples performed from 1991 to 2010 from the Wessex Regional Genetics Laboratory in England were extracted from the laboratory database. The numbers of diagnostic tests performed per Down, Edwards or Patau syndrome diagnosis were calculated according to the type of diagnostic test, and were adjusted for maternal age and gestational age at diagnosis. A total of 32,345 CVSs and amniocenteses identified 872 diagnoses of Down syndrome and 328 of Edwards and Patau syndrome. In 1991, there were 46 (95%CI: 16-111) CVSs per syndrome diagnosis compared with five (95%CI: 4-7) in 2010. For amniocenteses, the number fell from 53 (37-78) to 15 (11-22). This analysis demonstrates the improvements in antenatal screening for Down syndrome that have been made over the past 20 years, resulting in a reduction in the number of women tested and thus in the number of foetal deaths attributable to the testing procedure.
Morris, Joan K; Waters, Jonathan J; de Souza, E
2012-06-01
Pregnant women who receive a high screening risk result for Down, Edwards or Patau syndrome are offered diagnostic tests that carry a risk of miscarriage. This study determined how many women had such tests per syndrome diagnosis. The number of tests per Down, Edwards or Patau syndrome diagnosis adjusted for maternal and gestational age at diagnosis was calculated using routine data from 18 (95%) cytogenetic laboratories in England and Wales in 2008. There were 19,326 tests that identified 1118 diagnoses of Down syndrome and 615 of Edwards and Patau syndromes. There were eight chorionic villus samplings (CVS) per syndrome diagnosis compared with 16 amniocenteses (gestational age adjusted). The lowest number of tests per diagnosis (three for CVSs and for amniocentesis) resulted from an abnormal ultrasound scan. Among pregnant women, 2.9% had an invasive diagnostic test. If a CVS and an amniocentesis increase the risk of a miscarriage by 1% and 0.5%, respectively, approximately one miscarriage for every 14 Down, Edwards or Patau syndrome diagnosis would have occurred. A simple measurement of the population impact of screening for Down syndrome can be calculated using data already collected. Annual estimates should be produced to monitor the national fetal anomaly screening programme. © 2012 John Wiley & Sons, Ltd. © 2012 John Wiley & Sons, Ltd.
Grazioli, Gonzalo; Sanz de la Garza, Maria; Vidal, Barbara; Montserrat, Silvia; Sarquella-Brugada, Georgia; Pi, Ramon; Til, Lluis; Gutierrez, Josep; Brugada, Josep; Sitges, Marta
2017-09-01
Introduction Pre-participation screening in athletes attempts to reduce the incidence of sudden death during sports by identifying susceptible individuals. The objective of this study was to evaluate the diagnostic capacity of the different pre-participation screening points in adolescent athletes and the cost effectiveness of the programme. Methods Athletes were studied between 12-18 years old. Pre-participation screening included the American Heart Association questionnaire, electrocardiogram, echocardiogram, and stress test. The cost of test was established by the Catalan public health system. Results Of 1650 athletes included, 57% were men and mean age was 15.09 ± 1.82 years. Positive findings were identified as follows: in American Heart Association questionnaire 5.09% of subjects, in electrocardiogram 3.78%, in echocardiogram 4.96%, and in exercise test 1.75%. Six athletes (0.36%) were disqualified from participation and 10 (0.60%) were referred for interventional treatment. Diagnostic capacity was assessed by the area under the curve for detection of diseases that motivated disqualification for sport practice (American Heart Association questionnaire, 0.55; electrocardiogram, 0.72; echocardiogram, 0.88; stress test, 0.57). The cost for each athlete disqualified from the sport for a disease causing sudden death was €45,578. Conclusion The electrocardiogram and echocardiogram were the most useful studies to detect athletes susceptible to sudden death, and the stress test best diagnosed arrhythmias with specific treatment. In our country, pre-participatory screening was cost effective to detect athletes who might experience sudden death in sports.
[The prevalence of yaws among the Aka in the Congo].
Coldiron, M; Obvala, D; Mouniaman-Nara, I; Pena, J; Blondel, C; Porten, K
2013-05-01
This study, conducted in 2012 in two districts of the Congo (Bétou and Enyellé), screened for yaws (endemic treponemiasis) that could be treated by a single dose of azithromycin. The screening involved a clinical history, followed by a clinical examination of the children reporting dermatological problems. A rapid diagnostic test for treponema was performed on the children with suspicious lesions. Of 6215 children screened, 485 (7.8%) had such lesions; 480 (99.0%) of them had a rapid diagnostic test, and it was positive for 183 (38.1%). This so-called Morges strategy is aimed at eradicating yaws in endemic areas.
Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D
2014-03-01
Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.
Diagnostic Accuracy of the Veteran Affairs' Traumatic Brain Injury Screen.
Louise Bender Pape, Theresa; Smith, Bridget; Babcock-Parziale, Judith; Evans, Charlesnika T; Herrold, Amy A; Phipps Maieritsch, Kelly; High, Walter M
2018-01-31
To comprehensively estimate the diagnostic accuracy and reliability of the Department of Veterans Affairs (VA) Traumatic Brain Injury (TBI) Clinical Reminder Screen (TCRS). Cross-sectional, prospective, observational study using the Standards for Reporting of Diagnostic Accuracy criteria. Three VA Polytrauma Network Sites. Operation Iraqi Freedom, Operation Enduring Freedom veterans (N=433). TCRS, Comprehensive TBI Evaluation, Structured TBI Diagnostic Interview, Symptom Attribution and Classification Algorithm, and Clinician-Administered Posttraumatic Stress Disorder (PTSD) Scale. Forty-five percent of veterans screened positive on the TCRS for TBI. For detecting occurrence of historical TBI, the TCRS had a sensitivity of .56 to .74, a specificity of .63 to .93, a positive predictive value (PPV) of 25% to 45%, a negative predictive value (NPV) of 91% to 94%, and a diagnostic odds ratio (DOR) of 4 to 13. For accuracy of attributing active symptoms to the TBI, the TCRS had a sensitivity of .64 to .87, a specificity of .59 to .89, a PPV of 26% to 32%, an NPV of 92% to 95%, and a DOR of 6 to 9. The sensitivity was higher for veterans with PTSD (.80-.86) relative to veterans without PTSD (.57-.82). The specificity, however, was higher among veterans without PTSD (.75-.81) relative to veterans with PTSD (.36-.49). All indices of diagnostic accuracy changed when participants with questionably valid (QV) test profiles were eliminated from analyses. The utility of the TCRS to screen for mild TBI (mTBI) depends on the stringency of the diagnostic reference standard to which it is being compared, the presence/absence of PTSD, and QV test profiles. Further development, validation, and use of reproducible diagnostic algorithms for symptom attribution after possible mTBI would improve diagnostic accuracy. Published by Elsevier Inc.
Greening, S E; Grohs, D H; Guidos, B J
1997-01-01
Providing effective training, retraining and evaluation programs, including proficiency testing programs, for cytoprofessionals is a challenge shared by many academic and clinical educators internationally. In cytopathology the quality of training has immediately transferable and critically important impacts on satisfactory performance in the clinical setting. Well-designed interactive computer-assisted instruction and testing programs have been shown to enhance initial learning and to reinforce factual and conceptual knowledge. Computer systems designed not only to promote diagnostic accuracy but to integrate and streamline work flow in clinical service settings are candidates for educational adaptation. The AcCell 2000 system, designed as a diagnostic screening support system, offers technology that is adaptable to educational needs during basic and in-service training as well as testing of screening proficiency in both locator and identification skills. We describe the considerations, approaches and applications of the AcCell 2000 system in education programs for both training and evaluation of gynecologic diagnostic screening proficiency.
Diagnostic methods of TSH in thyroid screening tests.
Matyjaszek-Matuszek, Beata; Pyzik, Aleksandra; Nowakowski, Andrzej; Jarosz, Mirosław J
2013-01-01
Reliable and quick thyreologic diagnostics, as well as verification of the effectiveness of the therapy undertaken, is of great importance for the state of health of society. The measurement of plasma TSH is the commonly accepted and most sensitive screening test for primary thyroid disorders, which are the most frequent diseases related to the endocrine glands. At present, the available methods for the determination of TSH are characterized by high sensitivity ≤0.01 µIU/ml and lack of cross-reactivity. However, many drugs and substances, as well as pathological conditions, may affect the TSH level. evaluation of contemporary laboratory methods for the determination of TSH and the principles of interpretation of screening tests. In many countries, the TSH test is the only test performed in the diagnostics of thyroid function; nevertheless, it seems that for genuine and objective assessment of thyroid status the TSH level, together with FT4 level, should be absolutely determined, which allows the differentiation and assessment of the intensity of thyroid function disorders and foresee its consequences. The interpretation of TSH results in screening tests is different in such population groups as: children aged under 14, pregnant women, the elderly, and patients with non-thyroidal illnesses. From among currently used laboratory methods for determination of TSH levels, third generation non-isotopic methods are most frequently recommended, especially the method of immunochemiluminescence.
Juul, Jakob Søgaard; Andersen, Berit; Laurberg, Søren; Carlsen, Anders Helles; Olesen, Frede; Vedsted, Peter
2018-06-22
To investigate the diagnostic activity in general practice and the cumulative incidence of colorectal cancer (CRC) in individuals invited to the Danish national screening programme for CRC. A historical population-based cohort study. The Danish CRC screening programme and general practice. The 376,198 individuals invited to the Danish CRC screening programme from 1 March to 31 December 2014. The diagnostic activity (consultations and haemoglobin measures) in general practice in the year preceding the screening invitation and the cumulated incidence of CRC in the year following the screening invitation. Screening participants had significantly higher diagnostic activity than non-participants. Individuals with a positive faecal immunochemical test (FIT) had higher diagnostic activity compared to individuals with a negative FIT, and a small increase in the months leading up to the invitation. Individuals with a screen-detected CRC had lower diagnostic activity than individuals with no CRC. In total, 308 (25.3%) of CRCs diagnosed in the invited population were diagnosed outside the screening programme. Non-participants with CRC more often had low socio-economic status, high comorbidity and stage IV CRC than participants with CRC. There was a tendency that participants and those with a positive FIT had a higher diagnostic activity the year before the screening. This was not seen for those with CRC detected through screening. CRC must still be diagnosed in general practice in the invited population and non-participants are of special interest as they have higher risk of late stage CRC. Key Points Current awareness:Individuals with colorectal cancer (CRC) in screening may be symptomatic and CRC may still occur outside screening in the invited population. Most important points:The majority of individuals with CRC in screening cannot be expected to be diagnosed on symptomatic presentation in general practice GPs have to be aware that CRC still occurs outside screening in the invited population Non-participants with CRC are often deprived and have late stage CRC.
False-positive cancer screens and health-related quality of life.
McGovern, Patricia M; Gross, Cynthia R; Krueger, Richard A; Engelhard, Deborah A; Cordes, Jill E; Church, Timothy R
2004-01-01
By design, screening tests are imperfect-unresponsive to some cancers (false negatives) while occasionally raising suspicion of cancer where none exists (false positives). This pilot study describes patients' responses to having a false-positive screening test for cancer, and identifies screening effects on health-related quality of life (HRQoL). The pilot findings suggest issues important for incorporation in future evaluations of the impact of screening for prostate, lung, colon, or ovarian (PLCO) cancers. Seven focus groups were conducted to identify the nature and meaning of all phases of PLCO screening. Minnesota participants in the Prostate, Lung, Colorectal and Ovarian Cancer Screening Trial who had completed screening, with at least 1 false-positive screen, participated (N = 47). Participants' reactions to abnormal screens and diagnostic work-ups were primarily emotional (eg, anxiety and distress), not physical, and ultimately positive for the majority. Health distress and fear of cancer and death were the major negative aspects of HRQoL identified. These concepts are not typically included in generic HRQoL questionnaires like the SF-36, but are highly relevant to PLCO screening. Clinicians were regarded as underestimating the discomfort of follow-up diagnostic testing. However, relief and assurance appeared to eventually outweigh the negative emotions for most participants. Implications for oncology nurses include the need to consider the emotional consequences of screening in association with screen reliability and validity.
Leblanc, Judith; Hejblum, Gilles; Costagliola, Dominique; Durand-Zaleski, Isabelle; Lert, France; de Truchis, Pierre; Verbeke, Geert; Rousseau, Alexandra; Piquet, Hélène; Simon, François; Pateron, Dominique; Simon, Tabassome; Crémieux, Anne-Claude
2018-07-01
This study compares the effectiveness and cost-effectiveness of nurse-driven targeted HIV screening alongside physician-directed diagnostic testing (intervention strategy) with diagnostic testing alone (control strategy) in 8 emergency departments. In this cluster-randomized, 2-period, crossover trial, 18- to 64-year-old patients presenting for reasons other than potential exposure to HIV were included. The strategy applied first was randomly assigned. During both periods, diagnostic testing was prescribed by physicians following usual care. During the intervention periods, patients were asked to complete a self-administered questionnaire. According to their answers, the triage nurse suggested performing a rapid test to patients belonging to a high-risk group. The primary outcome was the proportion of new diagnoses among included patients, which further refers to effectiveness. A secondary outcome was the intervention's incremental cost (health care system perspective) per additional diagnosis. During the intervention periods, 74,161 patients were included, 16,468 completed the questionnaire, 4,341 belonged to high-risk groups, and 2,818 were tested by nurses, yielding 13 new diagnoses. Combined with 9 diagnoses confirmed through 97 diagnostic tests, 22 new diagnoses were established. During the control periods, 74,166 patients were included, 92 were tested, and 6 received a new diagnosis. The proportion of new diagnoses among included patients was higher during the intervention than in the control periods (3.0 per 10,000 versus 0.8 per 10,000; difference 2.2 per 10,000, 95% CI 1.3 to 3.6; relative risk 3.7, 95% CI 1.4 to 9.8). The incremental cost was €1,324 per additional new diagnosis. The combined strategy of targeted screening and diagnostic testing was effective. Copyright © 2017 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E
2016-02-01
It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.
Masi, Christopher M.; Blackman, Dionne J.; Peek, Monica E.
2009-01-01
The authors conduct a systematic review of the literature to identify interventions designed to enhance breast cancer screening, diagnosis, and treatment among minority women. Most trials in this area have focused on breast cancer screening, while relatively few have addressed diagnostic testing or breast cancer treatment. Among patient-targeted screening interventions, those that are culturally tailored or addressed financial or logistical barriers are generally more effective than reminder-based interventions, especially among women with fewer financial resources and those without previous mammography. Chart-based reminders increase physician adherence to mammography guidelines but are less effective at increasing clinical breast examination. Several trials demonstrate that case management is an effective strategy for expediting diagnostic testing after screening abnormalities have been found. Additional support for these and other proven health care organization-based interventions appears justified and may be necessary to eliminate racial and ethnic breast cancer disparities. PMID:17881627
Diagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis
Yan, Shirong; Liu, Zijing; Yu, Shuang; Bao, Yixi
2016-01-01
Background Septin9 is a member of GTP-binding protein family, and is used as a predictive diagnostic index. However, it has not been widely adopted due to inconsistent results reported in the literature. The present study was performed to determine the diagnostic accuracy of methylated Septin9 (mSEPT9) for colorectal cancer (CRC) and to evaluate its utility in CRC screening. Material/Methods After reviewing relevant studies, accuracy measures (pooled sensitivity and specificity, positive/negative likelihood ratio [PLR/NLR], and diagnostic odds ratio [DOR]) were calculated for mSEPT9 in the diagnosis of CRC. Overall test performance was summarized using summary receiver operating characteristic curve analysis. Potential between-study heterogeneity was explored by use of a meta-regression model. We divided included studies into Epi proColon test and non-Epi proColon test subgroups. We compared the effects of mSEPT9 and fecal occult blood test (FOBT) for CRC screening. Results A total of 9870 subjects in 14 studies were recruited. Pooled sensitivity and specificity, PLR, NLR, DOR, and corresponding 95% confidence intervals (CI) of mSEPT9 for CRC diagnosis were 0.66 (95% CI: 0.64–0.69), 0.91 (95% CI: 0.90–0.91), 5.59 (95% CI: 4.03–7.74), 0.37 (95% CI: 0.29–0.48), and 16.79 (95% CI: 10.54–26.76), respectively. The area under the summary ROC curve (AUC) was 0.8563. The AUCs in the Epi proColon test and non-Epi proColon test for CRC diagnosis were 0.8709 and 0.7968, respectively. In head-to-head comparison, AUC of mSEPT9 and FOBT for CRC diagnosis were 0.7857 and 0.6571, respectively. Conclusions The present study demonstrates that mSEPT9 can be a good diagnostic biomarker complementary to FOBT as a screening tool for CRC. PMID:27665580
Diagnostic Value of Methylated Septin9 for Colorectal Cancer Screening: A Meta-Analysis.
Yan, Shirong; Liu, Zijing; Yu, Shuang; Bao, Yixi
2016-09-25
BACKGROUND Septin9 is a member of GTP-binding protein family, and is used as a predictive diagnostic index. However, it has not been widely adopted due to inconsistent results reported in the literature. The present study was performed to determine the diagnostic accuracy of methylated Septin9 (mSEPT9) for colorectal cancer (CRC) and to evaluate its utility in CRC screening. MATERIAL AND METHODS After reviewing relevant studies, accuracy measures (pooled sensitivity and specificity, positive/negative likelihood ratio [PLR/NLR], and diagnostic odds ratio [DOR]) were calculated for mSEPT9 in the diagnosis of CRC. Overall test performance was summarized using summary receiver operating characteristic curve analysis. Potential between-study heterogeneity was explored by use of a meta-regression model. We divided included studies into Epi proColon test and non-Epi proColon test subgroups. We compared the effects of mSEPT9 and fecal occult blood test (FOBT) for CRC screening. RESULTS A total of 9870 subjects in 14 studies were recruited. Pooled sensitivity and specificity, PLR, NLR, DOR, and corresponding 95% confidence intervals (CI) of mSEPT9 for CRC diagnosis were 0.66 (95% CI: 0.64-0.69), 0.91 (95% CI: 0.90-0.91), 5.59 (95% CI: 4.03-7.74), 0.37 (95% CI: 0.29-0.48), and 16.79 (95% CI: 10.54-26.76), respectively. The area under the summary ROC curve (AUC) was 0.8563. The AUCs in the Epi proColon test and non-Epi proColon test for CRC diagnosis were 0.8709 and 0.7968, respectively. In head-to-head comparison, AUC of mSEPT9 and FOBT for CRC diagnosis were 0.7857 and 0.6571, respectively. CONCLUSIONS The present study demonstrates that mSEPT9 can be a good diagnostic biomarker complementary to FOBT as a screening tool for CRC.
Mamtani, Manju; Jawahirani, Anil; Das, Kishor; Rughwani, Vinky; Kulkarni, Hemant
2006-08-01
It is being increasingly recognized that a majority of the countries in the thalassemia-belt need a cost-effective screening program as the first step towards control of thalassemia. Although the naked eye single tube red cell osmotic fragility test (NESTROFT) has been considered to be a very effective screening tool for beta-thalassemia trait, assessment of its diagnostic performance has been affected with the reference test- and verification-bias. Here, we set out to provide estimates of sensitivity and specificity of NESTROFT corrected for these potential biases. We conducted a cross-sectional diagnostic test evaluation study using data from 1563 subjects from Central India with a high prevalence of beta-thalassemia. We used latent class modelling after ensuring its validity to account for the reference test bias and global sensitivity analysis to control the verification bias. We also compared the results of latent class modelling with those of five discriminant indexes. We observed that across a range of cut-offs for the mean corpuscular volume (MCV) and the hemoglobin A2 (HbA2) concentration the average sensitivity and specificity of NESTROFT obtained from latent class modelling was 99.8 and 83.7%, respectively. These estimates were comparable to those characterizing the diagnostic performance of HbA2, which is considered by many as the reference test to detect beta-thalassemia. After correction for the verification bias these estimates were 93.4 and 97.2%, respectively. Combined with the inexpensive and quick disposition of NESTROFT, these results strongly support its candidature as a screening tool-especially in the resource-poor and high-prevalence settings.
[Possibilities of the TruScreen for screening of precancer and cancer of the uterine cervix].
Zlatkov, V
2009-01-01
The classic approach of detection of pre-cancer and cancer of uterine cervix includes cytological examination, followed by colposcopy assessment of the detected cytological abnormalities. Real-time devices use in-vivo techniques for the measurement, computerized analysis and classifying of different types of cervical tissues. The aim of the present review is to present the technical characteristics and to discus the diagnostic possibilities of TruScreen-automated optical-electron system for cervical screening. The analysis of the presented in the literature diagnostic value of the method at different grades intraepithelial lesions shows that it has higher sensitivity (67-70%) and lower specificity (81%) in comparison to the Pap test with the following results (45-69% sensitivity and 95% specificity). This makes the method suitable for independent primary screening, as well as for adding the diagnostic assurance of the cytological method.
... Financial Planning Who Should I Tell? Genetic Testing & Counseling Compensation for Genetic Testing Whole Genome Sequencing Screening vs. Testing What Is Genetic Counseling? Participating in Research Disease Research Patient Privacy Clinical ...
Xie, Feng; O'Reilly, Daria; Ferrusi, Ilia L; Blackhouse, Gord; Bowen, James M; Tarride, Jean-Eric; Goeree, Ron
2009-05-01
The aim of this paper is to present an economic evaluation of diagnostic technologies using Helicobacter pylori screening strategies for the prevention of gastric cancer as an illustration. A Markov model was constructed to compare the lifetime cost and effectiveness of 4 potential strategies: no screening, the serology test by enzyme-linked immunosorbent assay (ELISA), the stool antigen test (SAT), and the (13)C-urea breath test (UBT) for the detection of H. pylori among a hypothetical cohort of 10,000 Canadian men aged 35 years. Special parameter consideration included the sensitivity and specificity of each screening strategy, which determined the model structure and treatment regimen. The primary outcome measured was the incremental cost-effectiveness ratio between the screening strategies and the no-screening strategy. Base-case analysis and probabilistic sensitivity analysis were performed using the point estimates of the parameters and Monte Carlo simulations, respectively. Compared with the no-screening strategy in the base-case analysis, the incremental cost-effectiveness ratio was $33,000 per quality-adjusted life-year (QALY) for the ELISA, $29,800 per QALY for the SAT, and $50,400 per QALY for the UBT. The probabilistic sensitivity analysis revealed that the no-screening strategy was more cost effective if the willingness to pay (WTP) was <$20,000 per QALY, while the SAT had the highest probability of being cost effective if the WTP was >$30,000 per QALY. Both the ELISA and the UBT were not cost-effective strategies over a wide range of WTP values. Although the UBT had the highest sensitivity and specificity, either no screening or the SAT could be the most cost-effective strategy depending on the WTP threshold values from an economic perspective. This highlights the importance of economic evaluations of diagnostic technologies.
Maternal age–based prenatal screening for chromosomal disorders
Carroll, June C.; Rideout, Andrea; Wilson, Brenda J.; Allanson, Judith; Blaine, Sean; Esplen, Mary Jane; Farrell, Sandra; Graham, Gail E.; MacKenzie, Jennifer; Meschino, Wendy S.; Prakash, Preeti; Shuman, Cheryl; Taylor, Sherry; Tobin, Stasey
2013-01-01
Objective To explore views of women and health care providers (HCPs) about the changing recommendations regarding maternal age–based prenatal screening. Design Mixed-methods design. Setting Ontario. Participants A sample of women who had given birth within the previous 2 years and who had attended a family medicine centre, midwifery practice, or baby and mother wellness program (n = 42); and a random sample of family physicians (n = 1600), and all Ontario obstetricians (n = 694) and midwives (n = 334) who provided prenatal care. Methods We used focus groups (FGs) to explore women's views. Content analysis was used to uncover themes and delineate meaning. To explore HCPs' views, we conducted a cross-sectional self-completion survey. Main findings All FG participants (42 women in 6 FGs) expressed the importance of individual choice of prenatal screening modality, regardless of age. They described their perception that society considers women older than 35 to be at high obstetric risk and raised concerns that change in the maternal age–related screening policy would require education. The HCP survey response rate was 40%. Results showed 24% of HCPs agreed that women of any age should be eligible for invasive diagnostic testing regardless of prenatal screening results; 15% agreed that the age for diagnostic testing should be increased to 40 years, 14% agreed that diagnostic testing should be reserved for women with positive prenatal screening results, and 45% agreed that prenatal screening should remain unchanged. Conclusion Maternity care organizations have recommended that maternal age–based prenatal screening is no longer appropriate. Informed choice is of paramount importance to women and should be part of any change. Health care providers need to be engaged in and educated about any change to screening guidelines to offer women informed choices. PMID:23341678
Braun, Tobias; Grüneberg, Christian; Thiel, Christian
2018-04-01
Routine screening for frailty could be used to timely identify older people with increased vulnerability und corresponding medical needs. The aim of this study was the translation and cross-cultural adaptation of the PRISMA-7 questionnaire, the FRAIL scale and the Groningen Frailty Indicator (GFI) into the German language as well as a preliminary analysis of the diagnostic test accuracy of these instruments used to screen for frailty. A diagnostic cross-sectional study was performed. The instrument translation into German followed a standardized process. Prefinal versions were clinically tested on older adults who gave structured in-depth feedback on the scales in order to compile a final revision of the German language scale versions. For the analysis of diagnostic test accuracy (criterion validity), PRISMA-7, FRAIL scale and GFI were considered the index tests. Two reference tests were applied to assess frailty, either based on Fried's model of a Physical Frailty Phenotype or on the model of deficit accumulation, expressed in a Frailty Index. Prefinal versions of the German translations of each instrument were produced and completed by 52 older participants (mean age: 73 ± 6 years). Some minor issues concerning comprehensibility and semantics of the scales were identified and resolved. Using the Physical Frailty Phenotype (frailty prevalence: 4%) criteria as a reference standard, the accuracy of the instruments was excellent (area under the curve AUC >0.90). Taking the Frailty Index (frailty prevalence: 23%) as the reference standard, the accuracy was good (AUC between 0.73 and 0.88). German language versions of PRISMA-7, FRAIL scale and GFI have been established and preliminary results indicate sufficient diagnostic test accuracy that needs to be further established.
Song, Lele; Jia, Jia; Peng, Xiumei; Xiao, Wenhua; Li, Yuemin
2017-06-08
The SEPT9 gene methylation assay is the first FDA-approved blood assay for colorectal cancer (CRC) screening. Fecal immunochemical test (FIT), FIT-DNA test and CEA assay are also in vitro diagnostic (IVD) tests used in CRC screening. This meta-analysis aims to review the SEPT9 assay performance and compare it with other IVD CRC screening tests. By searching the Ovid MEDLINE, EMBASE, CBMdisc and CJFD database, 25 out of 180 studies were identified to report the SEPT9 assay performance. 2613 CRC cases and 6030 controls were included, and sensitivity and specificity were used to evaluate its performance at various algorithms. 1/3 algorithm exhibited the best sensitivity while 2/3 and 1/1 algorithm exhibited the best balance between sensitivity and specificity. The performance of the blood SEPT9 assay is superior to that of the serum protein markers and the FIT test in symptomatic population, while appeared to be less potent than FIT and FIT-DNA tests in asymptomatic population. In conclusion, 1/3 algorithm is recommended for CRC screening, and 2/3 or 1/1 algorithms are suitable for early detection for diagnostic purpose. The SEPT9 assay exhibited better performance in symptomatic population than in asymptomatic population.
Rapid tests for sexually transmitted infections (STIs): the way forward
Peeling, R W; Holmes, K K; Mabey, D
2006-01-01
In the developing world, laboratory services for sexually transmitted infections (STIs) are either not available, or where limited services are available, patients may not be able to pay for or physically access those services. Despite the existence of national policy for antenatal screening to prevent congenital syphilis and substantial evidence that antenatal screening is cost‐effective, implementation of syphilis screening programmes remains unacceptably low because of lack of screening tools that can be used in primary health care settings. The World Health Organization Sexually Transmitted Diseases Diagnostics Initiative (SDI) has developed the ASSURED criteria as a benchmark to decide if tests address disease control needs: Affordable, Sensitive, Specific, User‐friendly, Rapid and robust, Equipment‐free and Deliverable to end‐users. Rapid syphilis tests that can be used with whole blood approach the ASSURED criteria and can now be deployed in areas where no previous screening has been possible. Although rapid tests for chlamydia and gonorrhoea lack sensitivity, more tests are in development. The way forward for STI diagnostics requires a continuing quest for ASSURED tests, the development of a road map for test introduction, sustainable programmes for quality assurance, and the creation of a robust infrastructure linked to HIV prevention that ensures sustainability of STI control efforts that includes viral STIs. PMID:17151023
Rapid tests for sexually transmitted infections (STIs): the way forward.
Peeling, R W; Holmes, K K; Mabey, D; Ronald, A
2006-12-01
In the developing world, laboratory services for sexually transmitted infections (STIs) are either not available, or where limited services are available, patients may not be able to pay for or physically access those services. Despite the existence of national policy for antenatal screening to prevent congenital syphilis and substantial evidence that antenatal screening is cost-effective, implementation of syphilis screening programmes remains unacceptably low because of lack of screening tools that can be used in primary health care settings. The World Health Organization Sexually Transmitted Diseases Diagnostics Initiative (SDI) has developed the ASSURED criteria as a benchmark to decide if tests address disease control needs: Affordable, Sensitive, Specific, User-friendly, Rapid and robust, Equipment-free and Deliverable to end-users. Rapid syphilis tests that can be used with whole blood approach the ASSURED criteria and can now be deployed in areas where no previous screening has been possible. Although rapid tests for chlamydia and gonorrhoea lack sensitivity, more tests are in development. The way forward for STI diagnostics requires a continuing quest for ASSURED tests, the development of a road map for test introduction, sustainable programmes for quality assurance, and the creation of a robust infrastructure linked to HIV prevention that ensures sustainability of STI control efforts that includes viral STIs.
Wormanns, D
2016-09-01
Pulmonary nodules are the most frequent pathological finding in low-dose computed tomography (CT) scanning for early detection of lung cancer. Early stages of lung cancer are often manifested as pulmonary nodules; however, the very commonly occurring small nodules are predominantly benign. These benign nodules are responsible for the high percentage of false positive test results in screening studies. Appropriate diagnostic algorithms are necessary to reduce false positive screening results and to improve the specificity of lung cancer screening. Such algorithms are based on some of the basic principles comprehensively described in this article. Firstly, the diameter of nodules allows a differentiation between large (>8 mm) probably malignant and small (<8 mm) probably benign nodules. Secondly, some morphological features of pulmonary nodules in CT can prove their benign nature. Thirdly, growth of small nodules is the best non-invasive predictor of malignancy and is utilized as a trigger for further diagnostic work-up. Non-invasive testing using positron emission tomography (PET) and contrast enhancement as well as invasive diagnostic tests (e.g. various procedures for cytological and histological diagnostics) are briefly described in this article. Different nodule morphology using CT (e.g. solid and semisolid nodules) is associated with different biological behavior and different algorithms for follow-up are required. Currently, no obligatory algorithm is available in German-speaking countries for the management of pulmonary nodules, which reflects the current state of knowledge. The main features of some international and American recommendations are briefly presented in this article from which conclusions for the daily clinical use are derived.
The Impact of Time-Series Diagnostic Tests on the Writing Ability of Iranian EFL Learners
ERIC Educational Resources Information Center
Atashgahi, Bahareh Molazem
2014-01-01
This study aimed to show whether administering a battery of time-series diagnostic tests (screening) has any impact on Iranian EFL learners' writing ability. The study was conducted on the intermediate EFL learners at Islamic Azad University North Tehran branch. The researcher administered a homogenizing test in order to exclude the exceptional…
Erten, Mujde Z; Fernandez, Luca P; Ng, Hank K; McKinnon, Wendy C; Heald, Brandie; Koliba, Christopher J; Greenblatt, Marc S
2016-10-01
Strategies to screen colorectal cancers (CRCs) for Lynch syndrome are evolving rapidly; the optimal strategy remains uncertain. We compared targeted versus universal screening of CRCs for Lynch syndrome. In 2010-2011, we employed targeted screening (age < 60 and/or Bethesda criteria). From 2012 to 2014, we screened all CRCs. Immunohistochemistry for the four mismatch repair proteins was done in all cases, followed by other diagnostic studies as indicated. We modeled the diagnostic costs of detecting Lynch syndrome and estimated the 5-year costs of preventing CRC by colonoscopy screening, using a system dynamics model. Using targeted screening, 51/175 (29 %) cancers fit criteria and were tested by immunohistochemistry; 15/51 (29 %, or 8.6 % of all CRCs) showed suspicious loss of ≥1 mismatch repair protein. Germline mismatch repair gene mutations were found in 4/4 cases sequenced (11 suspected cases did not have germline testing). Using universal screening, 17/292 (5.8 %) screened cancers had abnormal immunohistochemistry suspicious for Lynch syndrome. Germline mismatch repair mutations were found in only 3/10 cases sequenced (7 suspected cases did not have germline testing). The mean cost to identify Lynch syndrome probands was ~$23,333/case for targeted screening and ~$175,916/case for universal screening at our institution. Estimated costs to identify and screen probands and relatives were: targeted, $9798/case and universal, $38,452/case. In real-world Lynch syndrome management, incomplete clinical follow-up was the major barrier to do genetic testing. Targeted screening costs 2- to 7.5-fold less than universal and rarely misses Lynch syndrome cases. Future changes in testing costs will likely change the optimal algorithm.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marsh, G.M.; Callahan, C.; Pavlock, D.
In 1986, the Drake Health Registry Study initiated bladder cancer screening for 366 persons at high risk because of occupational exposure to beta-naphthylamine. The Drake Health Registry Study screening protocol consists of urinalysis, Papanicolaou cytology, and quantitative fluorescence image analysis. A positive screening test qualifies participants for a full diagnostic evaluation. The screening protocol has been modified during the first 3 years of the program's existence to address unexpected patterns of test results and to incorporate advances in screening technology. The current protocol, which has a two-tiered screening schedule, has been utilized successfully for 15 months. Of the 26 positivemore » results to date most have been based on abnormal Papanicolaou cytology and/or quantitative fluorescence image analysis. Bladder abnormalities were cited among most of the 18 study members who underwent diagnostic evaluation, including chronic cystitis, inflammation, hyperplasia, and dysplasia. We conclude that the screening program is detecting very early changes in a relatively young cohort and that these persons must be monitored over a number of years to ensure adequate medical surveillance.« less
Rapid plasma reagin test; Syphilis screening test ... Chernecky CC, Berger BJ. Rapid plasma regain (RPR) test – blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier ...
... people with HIV infection and AIDS. Exams and Tests DIAGNOSTIC TESTS These are tests that are done to check if you've ... general, testing is a 2-step process: Screening test. There are several kinds of tests. Some are ...
Ramkumar, Vidya; Selvakumar, K; Vanaja, C S; Hall, James W; Nagarajan, Roopa; Neethi, J
2016-10-01
Tele-diagnostic audiological testing in a hearing screening program for infants and young children is a novel practice, and this study is the first to explore its application in a rural community. It is important to understand parental perceptions and confidence when introducing a new process such as tele-audiological diagnostic testing in rural areas. A questionnaire with 17 rater-administered items was designed to elicit comments concerning the quality of tele-hearing testing and video-conferencing, access to tele-hearing testing, and parents' attitudes regarding tele-hearing testing in the village. The questionnaire was administered by an audiologist not involved in tele-diagnostic testing to avoid bias. Parents perceived tele-hearing testing as equal in quality to in-person testing. Technical factors such as good video-conferencing quality and logistical factors such as ease of access due to reasonable travel time to testing facility could have influenced these perceptions. While these results show tele-hearing testing is an acceptable alternative, occasional poor signal quality should be addressed prior to large-scale implementation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda
2015-02-01
Blood establishments routinely perform screening immunoassays to assess safety of the blood components. As with any other screening test, results have an inherent uncertainty. In blood establishments the major concern is the chance of false negatives, due to its possible impact on patients' health. This article briefly reviews GUM and diagnostic accuracy models for screening immunoassays, recommending a scheme to support the screening laboratories' staffs on the selection of a model considering the intended use of the screening results (i.e., post-transfusion safety). The discussion is grounded on a "risk-based thinking", risk being considered from the blood donor selection to the screening immunoassays. A combination of GUM and diagnostic accuracy models to evaluate measurement uncertainty in blood establishments is recommended. Copyright © 2014 Elsevier Ltd. All rights reserved.
Brennan, Marie-Luise; Schrijver, Iris
2016-01-01
Cystic fibrosis (CF) is an autosomal recessive disease with significant associated morbidity and mortality. It is now appreciated that the broad phenotypic CF spectrum is not explained by obvious genotype-phenotype correlations, suggesting that CF transmembrane conductance regulator (CFTR)-related disease may occur because of multiple additive effects. These contributing effects include complex CFTR alleles, modifier genes, mutations in alternative genes that produce CF-like phenotypes, epigenetic factors, and environmental influences. Most patients in the United States are now diagnosed through newborn screening and use of molecular testing methods. We review the molecular testing approaches and laboratory guidelines for carrier screening, prenatal testing, newborn screening, and clinical diagnostic testing, as well as recent developments in CF treatment, and reasons for the lack of a molecular diagnosis in some patients. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Students as Technicians: Screening Newborns for Cystic Fibrosis
ERIC Educational Resources Information Center
Gusky, Sharon
2014-01-01
In this activity, freshman college students learn biotechnology techniques while playing the role of a laboratory technician. They perform simulations of three diagnostic tests used to screen newborns for cystic fibrosis. By performing an ELISA, a PCR analysis, and a conductivity test, students learn how biotechnology techniques can be used to…
The CAST (Childhood Asperger Syndrome Test)
ERIC Educational Resources Information Center
Williams, Jo; Scott, Fiona; Stott, Carol; Allison, Carrie; Bolton, Patrick; Baron-Cohen, Simon; Brayne, Carol
2005-01-01
The Childhood Asperger Syndrome Test (CAST) is a parental questionnaire to screen for autism spectrum conditions. In this validation study, the CAST was distributed to 1925 children aged 5-11 in mainstream Cambridgeshire schools. A sample of participants received a full diagnostic assessment, conducted blind to screen status. The sensitivity of…
Current and future molecular diagnostics in colorectal cancer and colorectal adenoma.
Tsang, Andy Hin-Fung; Cheng, Ka-Ho; Wong, Apple Siu-Ping; Ng, Simon Siu-Man; Ma, Brigette Buig-Yue; Chan, Charles Ming-Lok; Tsui, Nancy Bo-Yin; Chan, Lawrence Wing-Chi; Yung, Benjamin Yat-Ming; Wong, Sze-Chuen Cesar
2014-04-14
Colorectal cancer (CRC) is one of the most prevalent cancers in developed countries. On the other hand, CRC is also one of the most curable cancers if it is detected in early stages through regular colonoscopy or sigmoidoscopy. Since CRC develops slowly from precancerous lesions, early detection can reduce both the incidence and mortality of the disease. Fecal occult blood test is a widely used non-invasive screening tool for CRC. Although fecal occult blood test is simple and cost-effective in screening CRC, there is room for improvement in terms of the accuracy of the test. Genetic dysregulations have been found to play an important role in CRC development. With better understanding of the molecular basis of CRC, there is a growing expectation on the development of diagnostic tests based on more sensitive and specific molecular markers and those tests may provide a breakthrough to the limitations of current screening tests for CRC. In this review, the molecular basis of CRC development, the characteristics and applications of different non-invasive molecular biomarkers, as well as the technologies available for the detection were discussed. This review intended to provide a summary on the current and future molecular diagnostics in CRC and its pre-malignant state, colorectal adenoma.
Current and future molecular diagnostics in colorectal cancer and colorectal adenoma
Tsang, Andy Hin-Fung; Cheng, Ka-Ho; Wong, Apple Siu-Ping; Ng, Simon Siu-Man; Ma, Brigette Buig-Yue; Chan, Charles Ming-Lok; Tsui, Nancy Bo-Yin; Chan, Lawrence Wing-Chi; Yung, Benjamin Yat-Ming; Wong, Sze-Chuen Cesar
2014-01-01
Colorectal cancer (CRC) is one of the most prevalent cancers in developed countries. On the other hand, CRC is also one of the most curable cancers if it is detected in early stages through regular colonoscopy or sigmoidoscopy. Since CRC develops slowly from precancerous lesions, early detection can reduce both the incidence and mortality of the disease. Fecal occult blood test is a widely used non-invasive screening tool for CRC. Although fecal occult blood test is simple and cost-effective in screening CRC, there is room for improvement in terms of the accuracy of the test. Genetic dysregulations have been found to play an important role in CRC development. With better understanding of the molecular basis of CRC, there is a growing expectation on the development of diagnostic tests based on more sensitive and specific molecular markers and those tests may provide a breakthrough to the limitations of current screening tests for CRC. In this review, the molecular basis of CRC development, the characteristics and applications of different non-invasive molecular biomarkers, as well as the technologies available for the detection were discussed. This review intended to provide a summary on the current and future molecular diagnostics in CRC and its pre-malignant state, colorectal adenoma. PMID:24744577
Katki, Hormuzd A; Schiffman, Mark
2018-05-01
Our work involves assessing whether new biomarkers might be useful for cervical-cancer screening across populations with different disease prevalences and biomarker distributions. When comparing across populations, we show that standard diagnostic accuracy statistics (predictive values, risk-differences, Youden's index and Area Under the Curve (AUC)) can easily be misinterpreted. We introduce an intuitively simple statistic for a 2 × 2 table, Mean Risk Stratification (MRS): the average change in risk (pre-test vs. post-test) revealed for tested individuals. High MRS implies better risk separation achieved by testing. MRS has 3 key advantages for comparing test performance across populations with different disease prevalences and biomarker distributions. First, MRS demonstrates that conventional predictive values and the risk-difference do not measure risk-stratification because they do not account for test-positivity rates. Second, Youden's index and AUC measure only multiplicative relative gains in risk-stratification: AUC = 0.6 achieves only 20% of maximum risk-stratification (AUC = 0.9 achieves 80%). Third, large relative gains in risk-stratification might not imply large absolute gains if disease is rare, demonstrating a "high-bar" to justify population-based screening for rare diseases such as cancer. We illustrate MRS by our experience comparing the performance of cervical-cancer screening tests in China vs. the USA. The test with the worst AUC = 0.72 in China (visual inspection with acetic acid) provides twice the risk-stratification (i.e. MRS) of the test with best AUC = 0.83 in the USA (human papillomavirus and Pap cotesting) because China has three times more cervical precancer/cancer. MRS could be routinely calculated to better understand the clinical/public-health implications of standard diagnostic accuracy statistics. Published by Elsevier Inc.
A diagnostic approach to hemochromatosis
Tavill, Anthony S; Adams, Paul C
2006-01-01
In the present clinical review, a diagnostic approach to hemochromatosis is discussed from the perspective of two clinicians with extensive experience in this area. The introduction of genetic testing and large-scale population screening studies have broadened our understanding of the clinical expression of disease and the utility of biochemical iron tests for the detection of disease and for the assessment of disease severity. Liver biopsy has become more of a prognostic test than a diagnostic test. The authors offer a stepwise, diagnostic algorithm based on current evidence-based data, that they regard as most cost-effective. An early diagnosis can lead to phlebotomy therapy to prevent the development of cirrhosis. PMID:16955151
Cho, Sung Jin; Lee, Jihoo; Lee, Hyun Jae; Jo, Hyun-Young; Sinniah, Mangalam; Kim, Hak-Yong; Chong, Chom-Kyu; Song, Hyun-Ok
2016-01-01
Rapid diagnostic tests (RDTs) can detect anti-malaria antibodies in human blood. As they can detect parasite infection at the low parasite density, they are useful in endemic areas where light infection and/or re-infection of parasites are common. Thus, malaria antibody tests can be used for screening bloods in blood banks to prevent transfusion-transmitted malaria (TTM), an emerging problem in malaria endemic areas. However, only a few malaria antibody tests are available in the microwell-based assay format and these are not suitable for field application. A novel malaria antibody (Ab)-based RDT using a differential diagnostic marker for falciparum and vivax malaria was developed as a suitable high-throughput assay that is sensitive and practical for blood screening. The marker, merozoite surface protein 1 (MSP1) was discovered by generation of a Plasmodium-specific network and the hierarchical organization of modularity in the network. Clinical evaluation revealed that the novel Malaria Pf/Pv Ab RDT shows improved sensitivity (98%) and specificity (99.7%) compared with the performance of a commercial kit, SD BioLine Malaria P.f/P.v (95.1% sensitivity and 99.1% specificity). The novel Malaria Pf/Pv Ab RDT has potential for use as a cost-effective blood-screening tool for malaria and in turn, reduces TTM risk in endemic areas.
Obuchowski, N A
2001-10-15
Electronic medical images are an efficient and convenient format in which to display, store and transmit radiographic information. Before electronic images can be used routinely to screen and diagnose patients, however, it must be shown that readers have the same diagnostic performance with this new format as traditional hard-copy film. Currently, there exist no suitable definitions of diagnostic equivalence. In this paper we propose two criteria for diagnostic equivalence. The first criterion ('population equivalence') considers the variability between and within readers, as well as the mean reader performance. This criterion is useful for most applications. The second criterion ('individual equivalence') involves a comparison of the test results for individual patients and is necessary when patients are followed radiographically over time. We present methods for testing both individual and population equivalence. The properties of the proposed methods are assessed in a Monte Carlo simulation study. Data from a mammography screening study is used to illustrate the proposed methods and compare them with results from more conventional methods of assessing equivalence and inter-procedure agreement. Copyright 2001 John Wiley & Sons, Ltd.
Baltzell, Kimberly A; Shakely, Deler; Hsiang, Michelle; Kemere, Jordan; Ali, Abdullah Suleiman; Björkman, Anders; Mårtensson, Andreas; Omar, Rahila; Elfving, Kristina; Msellem, Mwinyi; Aydin-Schmidt, Berit; Rosenthal, Philip J; Greenhouse, Bryan
2013-02-01
We screened for malaria in 594 blood samples from febrile patients who tested negative by a Plasmodium falciparum-specific histidine-rich protein-2-based rapid diagnostic test at 12 health facilities in Zanzibar districts North A and Micheweni, from May to August 2010. Screening was with microscopy, polymerase chain reaction (PCR) targeting the cytochrome b gene (cytbPCR) of the four major human malaria species, and quantitative PCR (qPCR). The prevalence of cytbPCR-detectable malaria infection was 2% (12 of 594), including 8 P. falciparum, 3 Plasmodium malariae, and 1 Plasmodium vivax infections. Microscopy identified 4 of 8 P. falciparum infections. Parasite density as estimated by microscopy or qPCR was > 4,000 parasites/μL in 5 of 8 cytbPCR-detectable P. falciparum infections. The infections that were missed by the rapid diagnostic test represent a particular challenge in malaria elimination settings and highlight the need for more sensitive point-of-care diagnostic tools to improve case detection of all human malaria species in febrile patients.
Snowsill, Tristan; Coelho, Helen; Huxley, Nicola; Jones-Hughes, Tracey; Briscoe, Simon; Frayling, Ian M; Hyde, Chris
2017-09-01
Inherited mutations in deoxyribonucleic acid (DNA) mismatch repair (MMR) genes lead to an increased risk of colorectal cancer (CRC), gynaecological cancers and other cancers, known as Lynch syndrome (LS). Risk-reducing interventions can be offered to individuals with known LS-causing mutations. The mutations can be identified by comprehensive testing of the MMR genes, but this would be prohibitively expensive in the general population. Tumour-based tests - microsatellite instability (MSI) and MMR immunohistochemistry (IHC) - are used in CRC patients to identify individuals at high risk of LS for genetic testing. MLH1 (MutL homologue 1) promoter methylation and BRAF V600E testing can be conducted on tumour material to rule out certain sporadic cancers. To investigate whether testing for LS in CRC patients using MSI or IHC (with or without MLH1 promoter methylation testing and BRAF V600E testing) is clinically effective (in terms of identifying Lynch syndrome and improving outcomes for patients) and represents a cost-effective use of NHS resources. Systematic reviews were conducted of the published literature on diagnostic test accuracy studies of MSI and/or IHC testing for LS, end-to-end studies of screening for LS in CRC patients and economic evaluations of screening for LS in CRC patients. A model-based economic evaluation was conducted to extrapolate long-term outcomes from the results of the diagnostic test accuracy review. The model was extended from a model previously developed by the authors. Ten studies were identified that evaluated the diagnostic test accuracy of MSI and/or IHC testing for identifying LS in CRC patients. For MSI testing, sensitivity ranged from 66.7% to 100.0% and specificity ranged from 61.1% to 92.5%. For IHC, sensitivity ranged from 80.8% to 100.0% and specificity ranged from 80.5% to 91.9%. When tumours showing low levels of MSI were treated as a positive result, the sensitivity of MSI testing increased but specificity fell. No end-to-end studies of screening for LS in CRC patients were identified. Nine economic evaluations of screening for LS in CRC were identified. None of the included studies fully matched the decision problem and hence a new economic evaluation was required. The base-case results in the economic evaluation suggest that screening for LS in CRC patients using IHC, BRAF V600E and MLH1 promoter methylation testing would be cost-effective at a threshold of £20,000 per quality-adjusted life-year (QALY). The incremental cost-effectiveness ratio for this strategy was £11,008 per QALY compared with no screening. Screening without tumour tests is not predicted to be cost-effective. Most of the diagnostic test accuracy studies identified were rated as having a risk of bias or were conducted in unrepresentative samples. There was no direct evidence that screening improves long-term outcomes. No probabilistic sensitivity analysis was conducted. Systematic review evidence suggests that MSI- and IHC-based testing can be used to identify LS in CRC patients, although there was heterogeneity in the methods used in the studies identified and the results of the studies. There was no high-quality empirical evidence that screening improves long-term outcomes and so an evidence linkage approach using modelling was necessary. Key determinants of whether or not screening is cost-effective are the accuracy of tumour-based tests, CRC risk without surveillance, the number of relatives identified for cascade testing, colonoscopic surveillance effectiveness and the acceptance of genetic testing. Future work should investigate screening for more causes of hereditary CRC and screening for LS in endometrial cancer patients. This study is registered as PROSPERO CRD42016033879. The National Institute for Health Research Health Technology Assessment programme.
Hu, Huiying; Jiang, Yulin; Zhang, Minghui; Liu, Shanying; Hao, Na; Zhou, Jing; Liu, Juntao; Zhang, Xiaojin; Ma, Liangkun
2017-03-01
To evaluate, side by side, the efficiency of dried blood spots (DBSs) against serum screening for Down's syndrome, and then, to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. One thousand eight hundred and thirty-seven low-risk Chinese women, with singleton pregnancy, were enrolled for the study. Alpha-fetoprotein and free beta human chorionic gonadotropin were measured for the serum as well as for the parallel DBS samples. Partial high-risk pregnant women identified by primary blood testing (n = 38) were also subject to the secondary cfDNA screening. Diagnostic amniocentesis was utilized to confirm the screening results. The true positive rate for Down's syndrome detection was 100% for both blood screening methods; however, the false-positive rate was 3.0% for DBS and 4.0% for serum screening, respectively. DBS correlated well with serum screening on Down's syndrome detection. Three out of 38 primary high-risk women displayed chromosomal abnormalities by cfDNA analysis, which were confirmed by amniocentesis. Either the true detection rate or the false-positive rate for Down's syndrome between DBS and the serum test is comparable. In addition, blood primary screening aligned with secondary cfDNA analysis, a "before and after" two-tier screening strategy, can massively decrease the false-positive rate, which, then, dramatically reduces the demand for invasive diagnostic operation. Impact statement Children born with Down's syndrome display a wide range of mental and physical disability. Currently, there is no effective treatment to ease the burden and anxiety of the Down's syndrome family and the surrounding society. This study is to evaluate the efficiency of dried blood spots against serum screening for Down's syndrome and to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. Results demonstrate that fetal cfDNA can significantly reduce false-positive rate close to none while distinguishing all true positives. Thus, we recommend that fetal cfDNA analysis to be utilized as a secondary screening tool atop of the primary blood protein screening to further minimize the capacity of undesirable invasive diagnostic operations.
Effectiveness of rapid prescreening and 10% rescreening in liquid-based Papanicolaou testing.
Currens, Heather S; Nejkauf, Katharine; Wagner, Lynn; Raab, Stephen S
2012-01-01
Although rapid prescreening (RPS) has been shown to be an effective quality control procedure for detecting false-negative conventional Papanicolaou (Pap) tests, RPS has not been widely implemented in the United States. In our laboratory, cytotechnologists performed RPS in 3,567 liquid-based Pap tests: 1,911 SurePath (BD Diagnostics-TriPath, Burlington, NC) preparations that were manually screened and 1,656 ThinPrep Pap tests (Hologic, Bedford, MA) that were imaged using the ThinPrep Imaging System (Hologic). We compared the sensitivity of RPS, 10% rescreening (R-10%), and routine screening (RS). In contrast with previously published findings, we found that RS + RPS did not improve screening sensitivity compared with RS + R-10%. These results support the following hypotheses: (1) Higher baseline RS sensitivity as a result of Pap test diagnoses standardization implemented for quality improvement purposes decreases the performance impact of RPS. (2) R-10% and RPS quality assurance methods detect diagnostic failures caused by different types of cognitive errors.
DeSalvo, Jennifer M; Young, Gregory S; Krok-Schoen, Jessica L; Paskett, Electra D
2017-06-01
This study aims to test the effectiveness of a patient navigation (PN) intervention to reduce time to diagnostic resolution among older adults age ≥65 years versus those <65 years with abnormal breast, cervical, or colorectal cancer screening exams participating in the Ohio Patient Navigation Research Program (OPNRP). The OPNRP utilized a nested cohort group-randomized trial design to randomize 862 participants ( n = 67 for ≥65 years; n = 795 for <65 years) to PN or usual care conditions. A shared frailty Cox model tested the effect of PN on time to resolution. Older adult participants randomized to PN achieved a 6-month resolution rate that was 127% higher than those randomized to usual care ( p = .001). This effect was not significantly different from participants <65 years. PN significantly reduced time to diagnostic resolution among older adults beginning 6 months after an abnormal cancer screening exam. Health care systems should include this population in PN programs to reduce cancer disparities.
Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea
Nebie, Yacouba K.; Koivogui, Lamine; Abiola, Nadine; Vansteelandt, Amanda; Worrel, Mary C.; Shang, Judith; Murphy, Louise B.; Fitter, David L.; Marston, Barbara J.; Martel, Lise
2017-01-01
Background Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT) for Ebola antigens could expand diagnostic capacity for Ebola virus disease. Objectives The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. Methods The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. Results There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. Conclusions Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion. PMID:28879148
Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D
2017-11-01
Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.
Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick
2015-01-01
Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020
[Validity criteria of a short test to assess speech and language competence in 4-year-olds].
Euler, H A; Holler-Zittlau, I; Minnen, S; Sick, U; Dux, W; Zaretsky, Y; Neumann, K
2010-11-01
A psychometrically constructed short test as a prerequisite for screening was developed on the basis of a revision of the Marburger Speech Screening to assess speech/language competence among children in Hessen (Germany). A total of 257 children (age 4.0 to 4.5 years) performed the test battery for speech/language competence; 214 children repeated the test 1 year later. Test scores correlated highly with scores of two competing language screenings (SSV, HASE) and with a combined score from four diagnostic tests of individual speech/language competences (Reynell III, patholinguistic diagnostics in impaired language development, PLAKSS, AWST-R). Validity was demonstrated by three comparisons: (1) Children with German family language had higher scores than children with another language. (2) The 3-month-older children achieved higher scores than younger children. (3) The difference between the children with German family language and those with another language was higher for the 3-month-older than for the younger children. The short test assesses the speech/language competence of 4-year-olds quickly, validly, and comprehensively.
Assessment of the efficacy of a hearing screening program for college students.
Taylor, Emily J; Emanuel, Diana C
2013-01-01
The Towson University (TU) Speech-Language-Hearing Center (SLHC) conducts annual hearing screenings for college students entering education or health-care professions. Hearing is screened in therapy rooms, and students who fail the screening are rescreened in a sound-treated booth. Students who fail the rescreening are referred for a comprehensive audiological assessment, which is offered at no cost to students at the SLHC. The purpose of this study was to examine the efficacy of the hearing screening program, to report trends in hearing screening statistics for the college student population, and to make recommendations regarding ways universities can optimize hearing screening programs. The study included retrospective and prospective portions. Hearing screening records were reviewed from 1999 to 2011. The prospective study involved recruiting students to participate in diagnostic testing following the hearing screening and measuring background noise levels in the therapy rooms. Hearing screening records from 1999 to 2011 were reviewed. In addition, during the three-day fall 2011 hearing screenings, 80 students were selected to participate in diagnostic testing. Data from the retrospective review were used to determine positive predictive value (PPV) between screening and rescreening. Return rates were also examined. For the prospective study, pure tone threshold results were compared to screening results to determine sensitivity, specificity, and PPV. The retrospective file review indicated that the hearing screening in the therapy room had poor PPV compared with the rescreening in the sound booth. Specifically, if a student failed the screening, they had only a 49% chance of failing the rescreening. This may have been due to background noise, as the prospective study found noise levels were higher than allowed by American National Standards Institute (ANSI) standard. Only a third of students referred for diagnostic testing from 1999 to 2010 returned for recommended diagnostic testing. For the prospective study, specificity and sensitivity were good when considering hearing loss present at the same frequencies as those screened (1000, 2000, 4000 Hz) but poor in comparison to hearing loss overall. The screening missed many students with a high frequency notch, which was most prevalent at 6000 Hz. The prevalence of a high frequency notch was 21 and 51%, using two different criteria for establishing the presence of a notch. If college hearing screenings are conducted in rooms that are not sound treated, poor PPV should be expected; thus, an immediate second stage rescreening for failures should be conducted in a sound booth. Hearing screenings limited to 1000, 2000, and 4000 Hz will miss many cases of hearing loss in the college-age population. College hearing screening program directors should carefully consider the purpose of the screening and adjust screening protocol, such as adding 6000 Hz and a question about noise exposure, in order to identify early signs of noise-induced hearing loss in college students. Programs should focus on ways to promote high return for follow-up rates. Estimates of prevalence of a high-frequency audiometric notch are highly dependent on the criteria used to define a notch. American Academy of Audiology.
Rosettenstein, Kerri; Viecelli, Andrea; Yong, Kenneth; Nguyen, Hung Do; Chakera, Aron; Chan, Doris; Dogra, Gursharan; Lim, Ee Mun; Wong, Germaine; Lim, Wai H
2016-07-01
New onset diabetes after transplantation (NODAT) is associated with a 3-fold greater risk of cardiovascular disease events, with early identification and treatment potentially attenuating this risk. The optimal screening test to identify those with NODAT remains unclear, and the aim of this study was to examine the diagnostic accuracies of 4 screening tests in identifying impaired fasting glucose, impaired glucose tolerance (IGT), and NODAT. This is a single-center prospective cohort study of 83 nondiabetic kidney transplant recipients between 2008 and 2011. Oral glucose tolerance test was considered the gold standard in identifying IFG/IGT or NODAT. Diagnostic accuracies of random blood glucose, glycated hemoglobin (HBA1c), fructosamine, and Homeostasis Model Assessment-Insulin Resistance in predicting IFG/IGT or NODAT were assessed using the area under the receiver operating characteristic curve. Forty (48%) recipients had IFG/IGT or NODAT. Compared with HBA1c with adjusted area under the curve (AUC) of 0.88 (95% confidence interval [95% CI], 0.77-0.93), fructosamine was the most accurate test with adjusted AUC of 0.92 (95% CI, 0.83-0.96). The adjusted AUCs of random blood glucose and Homeostasis Model Assessment-Insulin Resistance in identifying IFG/IGT were between 0.81 and 0.85. Restricting to identifying IGT/NODAT using 2-hour oral glucose tolerance test (n = 66), fructosamine was the most accurate diagnostic test with adjusted AUC of 0.93 (95% CI, 0.84-0.99), but not statistically different to HBA1c with adjusted AUC of 0.88 (95% CI, 0.76-0.96). Although HBA1c is an acceptable and widely used screening test in detecting IFG/IGT or NODAT, fructosamine may be a more accurate diagnostic test but this needs to be further examined in larger cohorts.
Field performance of clinical case definitions for influenza screening during the 2009 pandemic.
Chen, Shey-Ying; Chen, Yee-Chun; Chiang, Wen-Chu; Kung, Hsiang-Chi; King, Chwan-Chuen; Lai, Mei-Shu; Chie, Wei-Chu; Chen, Shyr-Chyr; Chen, Wen-Jone; Chang, Shan-Chwen
2012-11-01
The aim of this study was to assess the performance of 3 different influenza-like illness (ILI) case definitions, adopted by the European (European-CDC), USA (USA-CDC), and Taiwan Centers for Disease Prevention and Control (Taiwan-CDC), as screening tools for influenza during the 2009 H1N1 pandemic. From August 15 to 30, 2009, all emergency department patients with clinical symptoms or at epidemiologic risk for influenza were enrolled in an observational cohort study. Influenza diagnosis was established by positive rapid influenza diagnostic test or virus isolation. Sensitivity, specificity, positive predictive value, and negative predictive value of the European-, USA, and Taiwan-CDC ILI case definitions for screening were determined. A total of 870 patients were screened during the study period. Rapid influenza diagnostic test was positive in 315 patients, 273 (85.6%) of whom had fever duration less than 72 hours. Virus isolation identified 4 more patients with influenza A initially negative by rapid influenza diagnostic test. The mean (SD) age of these 319 patients was 24.3 (18.1) years. Of the 870 screened patients, 670 (77.0%), 476 (54.7%), and 325 (37.4%) met the European-, USA-, and Taiwan-CDC ILI case definition, respectively. Screening sensitivity was 95%, 77.7%, and 57.7% and specificity was 33.4%, 58.6%, and 74.4%, respectively. Differences in sensitivity and specificity between any 2 of the 3 groups were statistically significant (P < .05). First-line physicians should recognize the advantage and limitation of different ILI case definitions in influenza screening, especially confronted by pandemic or highly pathogenic avian influenza in the future. Copyright © 2012 Elsevier Inc. All rights reserved.
Van Norman, Ethan R; Nelson, Peter M; Klingbeil, David A
2017-09-01
Educators need recommendations to improve screening practices without limiting students' instructional opportunities. Repurposing previous years' state test scores has shown promise in identifying at-risk students within multitiered systems of support. However, researchers have not directly compared the diagnostic accuracy of previous years' state test scores with data collected during fall screening periods to identify at-risk students. In addition, the benefit of using previous state test scores in conjunction with data from a separate measure to identify at-risk students has not been explored. The diagnostic accuracy of 3 types of screening approaches were tested to predict proficiency on end-of-year high-stakes assessments: state test data obtained during the previous year, data from a different measure administered in the fall, and both measures combined (i.e., a gated model). Extant reading and math data (N = 2,996) from 10 schools in the Midwest were analyzed. When used alone, both measures yielded similar sensitivity and specificity values. The gated model yielded superior specificity values compared with using either measure alone, at the expense of sensitivity. Implications, limitations, and ideas for future research are discussed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Wu, Hon-Yen; Peng, Yu-Sen; Chiang, Chih-Kang; Huang, Jenq-Wen; Hung, Kuan-Yu; Wu, Kwan-Dun; Tu, Yu-Kang; Chien, Kuo-Liong
2014-07-01
A random urine sample measuring the albumin concentration (UAC) without simultaneously measuring the urinary creatinine is less expensive than measuring the ratio of albumin to creatinine (ACR), but comparisons of their diagnostic performance for microalbuminuria screening among patients with diabetes mellitus (DM) have not been undertaken in previous meta-analyses. To compare the diagnostic performance of the UAC vs the ACR in random urine samples for microalbuminuria screening among patients with DM. Electronic literature searches of PubMed, MEDLINE, and Scopus for English-language publications from the earliest available date of indexing through July 31, 2012. Clinical studies assessing the UAC or the ACR of random urine samples in detecting the presence of microalbuminuria among patients with DM using a urinary albumin excretion rate of 30 to 300 mg/d in 24-hour timed urine collections as the criterion standard. Bivariate random-effects models for analysis and pooling of the diagnostic performance measures across studies, as well as comparisons between different screening tests. The primary end point was the diagnostic performance measures of the UAC or the ACR in random urine samples, as well as comparisons between them. We identified 14 studies, with a total of 2078 patients; 9 studies reported on the UAC, and 12 studies reported on the ACR. Meta-analysis showed pooled sensitivities of 0.85 and 0.87 for the UAC and the ACR, respectively, and pooled specificities of 0.88 and 0.88, respectively. No differences in sensitivity (P = .70), specificity (P = .63), or diagnostic odds ratios (P = .59) between the UAC and the ACR were found. The time point of urine collection did not affect the diagnostic performance of either test. The UAC and the ACR yielded high sensitivity and specificity for the detection of microalbuminuria. Because the diagnostic performance of the UAC is comparable to that of the ACR, our findings indicate that the UAC of random urine samples may become the screening tool of choice for the population with DM, considering the rising incidence of DM and the constrained health care resources in many countries.
Kurtbas, Handan; Keskin, H Levent; Avsar, A Filiz
2011-06-01
To assess the incidence of gestational diabetes mellitus (GDM) beyond 30 gestational weeks (GW) in pregnant Turkish women and to determine the criteria for repeating the test during the late period of gestation when the results were normal after the initial screen. Two hundred pregnant women were enrolled. Maternal age, gravidity, parity and presence of other risk factors (family history of diabetes mellitus, habitual abortions, prior fetal macrosomia, obesity, gestational hypertension history) were collected. First, GDM was evaluated between the 24th and 28th GW by screening (50-g glucose challenge test) and diagnostic tests. This protocol was repeated again at least 1 month from the first screen at the 30th-34th GW in all patients, except those diagnosed with GDM due to an abnormal 3-h test. The results were compared with the clinical risk factors. In total, 19.5% of the cases had positive results in the first screening test. Six patients were diagnosed with GDM. Among the remaining 194 pregnancies, another 10 cases were diagnosed as having GDM with repeated tests, and the incidence of newly diagnosed GDM was 5.2%. Only the mean age (34.2 years) (P = 0.010) and a history of delivering a macrosomic infant (P < 0.010) were significantly high in the late-gestation GDM-positive cases. Even when early screening tests are negative, pregnancies with advanced maternal ages and those with a history of delivering a macrosomic infant should be re-evaluated for GDM during the late gestational period with screening and diagnostic tests. © 2011 The Authors. Journal of Obstetrics and Gynaecology Research © 2011 Japan Society of Obstetrics and Gynecology.
Adu-Gyasi, Dennis; Asante, Kwaku Poku; Newton, Sam; Dosoo, David; Amoako, Sabastina; Adjei, George; Amoako, Nicholas; Ankrah, Love; Tchum, Samuel Kofi; Mahama, Emmanuel; Agyemang, Veronica; Kayan, Kingsley; Owusu-Agyei, Seth
2015-01-01
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most widespread enzyme defect that can result in red cell breakdown under oxidative stress when exposed to certain medicines including antimalarials. We evaluated the diagnostic accuracy of CareStart G6PD deficiency Rapid Diagnostic Test (RDT) as a point-of-care tool for screening G6PD deficiency. A cross-sectional study was conducted among 206 randomly selected and consented participants from a group with known G6PD deficiency status between February 2013 and June 2013. A maximum of 1.6ml of capillary blood samples were used for G6PD deficiency screening using CareStart G6PD RDT and Trinity qualitative with Trinity quantitative methods as the "gold standard". Samples were also screened for the presence of malaria parasites. Data entry and analysis were done using Microsoft Access 2010 and Stata Software version 12. Kintampo Health Research Centre Institutional Ethics Committee granted ethical approval. The sensitivity (SE) and specificity (SP) of CareStart G6PD deficiency RDT was 100% and 72.1% compared to Trinity quantitative method respectively and was 98.9% and 96.2% compared to Trinity qualitative method. Malaria infection status had no significant (P=0.199) change on the performance of the G6PD RDT test kit compared to the "gold standard". The outcome of this study suggests that the diagnostic performance of the CareStart G6PD deficiency RDT kit was high and it is acceptable at determining the G6PD deficiency status in a high malaria endemic area in Ghana. The RDT kit presents as an attractive tool for point-of-care G6PD deficiency for rapid testing in areas with high temperatures and less expertise. The CareStart G6PD deficiency RDT kit could be used to screen malaria patients before administration of the fixed dose primaquine with artemisinin-based combination therapy.
Short-Term Outcomes of Screening Mammography Using Computer-Aided Detection
Fenton, Joshua J.; Xing, Guibo; Elmore, Joann G.; Bang, Heejung; Chen, Steven L.; Lindfors, Karen K.; Baldwin, Laura-Mae
2013-01-01
Background Computer-aided detection (CAD) has rapidly diffused into screening mammography practice despite limited and conflicting data on its clinical effect. Objective To determine associations between CAD use during screening mammography and the incidence of ductal carcinoma in situ (DCIS) and invasive breast cancer, invasive cancer stage, and diagnostic testing. Design Retrospective cohort study. Setting Medicare program. Participants Women aged 67 to 89 years having screening mammography between 2001 and 2006 in U.S. SEER (Surveillance, Epidemiology and End Results) regions (409 459 mammograms from 163 099 women). Measurements Incident DCIS and invasive breast cancer within 1 year after mammography, invasive cancer stage, and diagnostic testing within 90 days after screening among women without breast cancer. Results From 2001 to 2006, CAD prevalence increased from 3.6% to 60.5%. Use of CAD was associated with greater DCIS incidence (adjusted odds ratio [OR], 1.17 [95% CI, 1.11 to 1.23]) but no difference in invasive breast cancer incidence (adjusted OR, 1.00 [CI, 0.97 to 1.03]). Among women with invasive cancer, CAD was associated with greater likelihood of stage I to II versus III to IV cancer (adjusted OR, 1.27 [CI, 1.14 to 1.41]). In women without breast cancer, CAD was associated with increased odds of diagnostic mammography (adjusted OR, 1.28 [CI, 1.27 to 1.29]), breast ultrasonography (adjusted OR, 1.07 [CI, 1.06 to 1.09]), and breast biopsy (adjusted OR, 1.10 [CI, 1.08 to 1.12]). Limitation Short follow-up for cancer stage, potential unmeasured confounding, and uncertain generalizability to younger women. Conclusion Use of CAD during screening mammography among Medicare enrollees is associated with increased DCIS incidence, the diagnosis of invasive breast cancer at earlier stages, and increased diagnostic testing among women without breast cancer. Primary Funding Source Center for Healthcare Policy and Research, University of California, Davis. PMID:23588746
Li, Rui; Liu, Jianjun; Xue, Huiping; Huang, Gang
2012-10-15
The measurement of fecal tumor M2-pyruvate kinase (PKM2), overexpressed in tumor cells, has been proposed as a novel tool for detecting colorectal cancer (CRC). However, the sensitivity and specificity of this test varied among studies. The aim of this meta-analysis was to determine the diagnostic accuracy of fecal PKM2 for CRC and to evaluate its utility in the CRC screening. It was compared to guaiac fecal occult blood test (gFOBT) or immunological fecal occult blood test (iFOBT). Through comprehensive literature search, 10 studies met the inclusion criteria and were included. Summary estimates for sensitivity and specificity were calculated by using the bivariate random effect model. The hierarchical summary receiver operating characteristic curve was also undertaken. The overall sensitivity and specificity of fecal PKM2 for detecting CRC were 79% (95% CI = 75-83%) and 81% (95% CI = 73-87%), respectively. The summary positive predictive value and negative predictive value were 74% (95% CI = 56-87%) and 86% (95% CI = 79-91%), respectively. The pooled diagnostic odds ratio was 16 (95% CI = 10-26). In head-to-head comparison, the diagnostic odds ratio of PKM2 and gFOBT for CRC were 10.167 (95% CI = 5.992-17.250) and 6.557 (95% CI = 3.467-12.403), respectively. The diagnostic odds ratio of PKM2 and iFOBT for CRC were 9.542 (95% CI = 5.893-15.452) and 67.248 (95% CI = 16.194-279.26), respectively. The fecal PKM2 test was a diagnostic tool with moderate sensitivity and specificity for detecting CRC. Its diagnostic efficiency was similar to that of gFOBT. Because of its relatively low specificity and positive predict value, fecal PKM2 was not recommended used alone as a screening tool for CRC. Copyright © 2012 UICC.
2012 HIV Diagnostics Conference: the molecular diagnostics perspective.
Branson, Bernard M; Pandori, Mark
2013-04-01
2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.
Cunha, Burke A; Syed, Uzma; Stroll, Stephanie; Mickail, Nardeen; Laguerre, Marianne
2009-01-01
In spring 2009, a novel strain of influenza A originating in Veracruz, Mexico, quickly spread to the United States and throughout the world. This influenza A virus was the product of gene reassortment of 4 different genetic elements: human influenza, swine influenza, avian influenza, and Eurasian swine influenza. In the United States, New York was the epicenter of the swine influenza (H1N1) pandemic. Hospital emergency departments (EDs) were inundated with patients with influenza-like illnesses (ILIs) requesting screening for H1N1. Our ED screening, as well as many others, used a rapid screening test for influenza A (QuickVue A/B) because H1N1 was a variant of influenza A. The definitive laboratory test i.e., RT-PCR for H1N1 was developed by the Centers for Disease Control (Atlanta, GA) and subsequently distributed to health departments. Because of the extraordinary volume of test requests, health authorities restricted reverse transcription polymerase chain reaction (RT-PCR) testing. Hence most EDs, including our own, were dependent on rapid influenza diagnostic tests (RIDTs) for swine influenza. A positive rapid influenza A test was usually predictive of RT-PCR H1N1 positivity, but the rapid influenza A screening test (QuickVue A/B) was associated with 30% false negatives. The inability to rely on RIDTs for H1N1 diagnosis resulted in underdiagnosing H1N1. Confronted with adults admitted with ILIs, negative RIDTs, and restricted RT-PCR testing, there was a critical need to develop clinical criteria to diagnose probable swine influenza H1N1 pneumonia. During the pandemic, the Infectious Disease Division at Winthrop-University Hospital developed clinical criteria for adult admitted patients with ILIs and negative RIDTs. Similar to the one developed for the clinical diagnosis of legionnaire's disease. The Winthrop-University Hospital Infectious Disease Division's diagnostic weighted point score system for swine influenza H1N1 pneumonia is based on key clinical and laboratory features. During the "herald" wave of the swine influenza H1N1 pandemic, the diagnostic weighted point score system accurately identified probable swine influenza H1N1 pneumonia and accurately differentiated swine influenza H1N1 pneumonia from ILIs and other viral and bacterial community-acquired pneumonias. In hospitalized adults with ILIs and negative RIDTs, the diagnostic weighted diagnostic point score system, may be used to make a presumptive clinical diagnosis of swine influenza H1N1 pneumonia.
2013-01-01
Background The bulk of service delivery in dentistry is delivered by general dental practitioners, when a large proportion of patients who attend regularly are asymptomatic and do not require treatment. This represents a substantial and unnecessary cost, given that it is possible to delegate a range of tasks to dental care professionals, who are a less expensive resource. Screening for the common dental diseases by dental care professionals has the potential to release general dental practitioner’s time and increase the capacity to care for those who don't currently access services. The aim of this study is to compare the diagnostic test accuracy of dental care professionals when screening for dental caries and periodontal disease in asymptomatic adults aged eighteen years of age. Methods/design Ten dental practices across the North-West of England will take part in a diagnostic test accuracy study with 200 consecutive patients in each practice. The dental care professionals will act as the index test and the general dental practitioner will act as the reference test. Consenting asymptomatic patients will enter the study and see either the dental care professionals or general dental practitioner first to remove order effects. Both sets of clinicians will make an assessment of dental caries and periodontal disease and enter their decisions on a record sheet for each participant. The primary outcome measure is the diagnostic test accuracy of the dental care professionals and sensitivity, specificity, positive predictive value and negative predictive values will be reported. A number of clinical factors will be assessed for confounding. Discussion The results of this study will determine whether dental care professionals can screen for the two most prevalent oral diseases. This will inform the literature and is apposite given the recent policy change in the United Kingdom towards direct access. PMID:24053760
Maternal Serologic Screening to Prevent Congenital Toxoplasmosis: A Decision-Analytic Economic Model
Stillwaggon, Eileen; Carrier, Christopher S.; Sautter, Mari; McLeod, Rima
2011-01-01
Objective To determine a cost-minimizing option for congenital toxoplasmosis in the United States. Methodology/Principal Findings A decision-analytic and cost-minimization model was constructed to compare monthly maternal serological screening, prenatal treatment, and post-natal follow-up and treatment according to the current French (Paris) protocol, versus no systematic screening or perinatal treatment. Costs are based on published estimates of lifetime societal costs of developmental disabilities and current diagnostic and treatment costs. Probabilities are based on published results and clinical practice in the United States and France. One- and two-way sensitivity analyses are used to evaluate robustness of results. Universal monthly maternal screening for congenital toxoplasmosis with follow-up and treatment, following the French protocol, is found to be cost-saving, with savings of $620 per child screened. Results are robust to changes in test costs, value of statistical life, seroprevalence in women of childbearing age, fetal loss due to amniocentesis, and to bivariate analysis of test costs and incidence of primary T. gondii infection in pregnancy. Given the parameters in this model and a maternal screening test cost of $12, screening is cost-saving for rates of congenital infection above 1 per 10,000 live births. If universal testing generates economies of scale in diagnostic tools—lowering test costs to about $2 per test—universal screening is cost-saving at rates of congenital infection well below the lowest reported rates in the United States of 1 per 10,000 live births. Conclusion/Significance Universal screening according to the French protocol is cost saving for the US population within broad parameters for costs and probabilities. PMID:21980546
Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho
2017-08-01
The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.
How to report and interpret screening test properties: guidelines for driving researchers.
Weaver, Bruce; Walter, Stephen D; Bédard, Michel
2014-01-01
One important goal of driving research is the development of a short but valid office-based screening test for fitness to drive of aging drivers. Several candidate tests have been proposed already, and no doubt others will be proposed in the future. It might seem obvious that authors advocating for the adoption of a particular screening test or procedure should report sensitivity, specificity, and other common screening test properties. Unfortunately, driving researchers have frequently failed to report any screening test properties. Others have reported screening test properties but have made basic mistakes such as calculating predictive values of positive and negative tests but reporting them incorrectly as sensitivity and specificity. These omissions and errors suggest that some driving researchers may be unaware of the importance of accurately reporting test properties when proposing a screening procedure and that others may need a refresher on how to calculate and interpret the most common screening test properties. Many good learning resources for screening and diagnostic tests are available, but most of them are intended for students and researchers in medicine, epidemiology, or public health. We hope that this tutorial in a prominent transportation journal will help lead to improved reporting and interpretation of screening test properties in articles that assess the usefulness of potential screening tools for fitness to drive.
Purcell, Susan E; Rhea, Karen; Maier, Philip; First, Michael; Zweede, Lisa; Sinisterra, Manuela; Nunn, M Brad; Austin, Marie-Paule; Brodey, Inger S
2018-01-01
Background The Structured Clinical Interview for DSM (SCID) is considered the gold standard assessment for accurate, reliable psychiatric diagnoses; however, because of its length, complexity, and training required, the SCID is rarely used outside of research. Objective This paper aims to describe the development and initial validation of a Web-based, self-report screening instrument (the Screening Assessment for Guiding Evaluation-Self-Report, SAGE-SR) based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) and the SCID-5-Clinician Version (CV) intended to make accurate, broad-based behavioral health diagnostic screening more accessible within clinical care. Methods First, study staff drafted approximately 1200 self-report items representing individual granular symptoms in the diagnostic criteria for the 8 primary SCID-CV modules. An expert panel iteratively reviewed, critiqued, and revised items. The resulting items were iteratively administered and revised through 3 rounds of cognitive interviewing with community mental health center participants. In the first 2 rounds, the SCID was also administered to participants to directly compare their Likert self-report and SCID responses. A second expert panel evaluated the final pool of items from cognitive interviewing and criteria in the DSM-5 to construct the SAGE-SR, a computerized adaptive instrument that uses branching logic from a screener section to administer appropriate follow-up questions to refine the differential diagnoses. The SAGE-SR was administered to healthy controls and outpatient mental health clinic clients to assess test duration and test-retest reliability. Cutoff scores for screening into follow-up diagnostic sections and criteria for inclusion of diagnoses in the differential diagnosis were evaluated. Results The expert panel reduced the initial 1200 test items to 664 items that panel members agreed collectively represented the SCID items from the 8 targeted modules and DSM criteria for the covered diagnoses. These 664 items were iteratively submitted to 3 rounds of cognitive interviewing with 50 community mental health center participants; the expert panel reviewed session summaries and agreed on a final set of 661 clear and concise self-report items representing the desired criteria in the DSM-5. The SAGE-SR constructed from this item pool took an average of 14 min to complete in a nonclinical sample versus 24 min in a clinical sample. Responses to individual items can be combined to generate DSM criteria endorsements and differential diagnoses, as well as provide indices of individual symptom severity. Preliminary measures of test-retest reliability in a small, nonclinical sample were promising, with good to excellent reliability for screener items in 11 of 13 diagnostic screening modules (intraclass correlation coefficient [ICC] or kappa coefficients ranging from .60 to .90), with mania achieving fair test-retest reliability (ICC=.50) and other substance use endorsed too infrequently for analysis. Conclusions The SAGE-SR is a computerized adaptive self-report instrument designed to provide rigorous differential diagnostic information to clinicians. PMID:29572204
2014-01-01
Background Speed Leish K® is used as a serological screening test for Leishmania infection prior to vaccination. Limited comparative serological studies with Speed Leish K® have been performed. The aim of this study was to evaluate the diagnostic performance of four commercially available serologic tests including ELISAs (Leiscan®, ID Screen® and Leishmania 96®), a rapid test (Speed Leish K®) and an in-house IFAT for the detection of specific antibodies against Leishmania infantum antigen in dogs in different states of infection. Methods Sick infected dogs (n = 36), healthy infected dogs (n = 18), L. infantum seropositive dogs with low to high levels of antibodies (n = 53), dogs seropositive to other pathogens (to evaluate cross reaction) (n = 14) and uninfected dogs from a non-endemic area (n = 50) and from an endemic area (n = 32) were analysed by the serological methods mentioned above. Results The sensitivity was as follows: ID Screen® (0.953), Leiscan® and Leishmania 96® (0.925), IFAT (0.869) and Speed Leish K® (0.636). The maximum specificity (1.000) was attained for all diagnostic tests except the Leishmania 96® (0.896) and IFAT (0.917). The accuracy was as follows: ID Screen® (0.975), Leiscan® (0.961), Leishmania 96® (0.911), IFAT (0.892) and Speed Leish K® (0.808). In relation to the area under the ROC curve (AUC-ROC), the maximum value was attained with the ID Screen® (0.993) closely followed by Leiscan® (0.990), then, Leishmania 96® (0.962), IFAT (0.926) and Speed Leish K® (0.818). For the Kappa index, the best result was obtained by the ID Screen® (0.951) followed by Leiscan® (0.921), Leishmania 96® (0.822), IFAT (0.783) and Speed Leish K® (0.622). Statistically significant differences were found between the AUC-ROC of quantitative serological tests and the only qualitative rapid test evaluated. There were also statistically significant differences between AUC-ROC of the ELISAs (ID Screen® and Leiscan®) and IFAT. Conclusions Leiscan® and ID Screen® had superior diagnostic performance measures than IFAT and all quantitative serological tests were superior when compared to Speed Leish K®. Thus, Speed Leish K® may be considered a less valuable screening test prior to vaccination as it may result in vaccination of seropositive dogs and in some cases seropositive sick dogs. PMID:24655335
Identification of Patients at Risk for Hereditary Colorectal Cancer
Mishra, Nitin; Hall, Jason
2012-01-01
Diagnosis of hereditary colorectal cancer syndromes requires clinical suspicion and knowledge of such syndromes. Lynch syndrome is the most common cause of hereditary colorectal cancer. Other less common causes include familial adenomatous polyposis (FAP), Peutz-Jeghers syndrome (PJS), juvenile polyposis syndrome, and others. There have been a growing number of clinical and molecular tools used to screen and test at risk individuals. Screening tools include diagnostic clinical criteria, family history, genetic prediction models, and tumor testing. Patients who are high risk based on screening should be referred for genetic testing. PMID:23730221
Sharipova, I N; Khodak, N M; Puzirev, V F; Burkov, A N; Ulanova, T I
2015-03-01
The detection of false positive serological reactions (FPSR) on HIV-infection under screening examination of pregnant women is an actual problem of practical health care. The original observations testify that under analysis of the same samples of blood serum of pregnant women using screening immune enzyme test-systems of various manufacturers the unmatched data concerning FPSR can be obtained. The purpose of this study was to implement comparative evaluation of specificity of immune enzyme test-systems of three different manufacturers: "DS-IFA-HIV-AGAT-SCREEN" ("Diagnostic Systems"), "Genscreen Ultra HIV Ag-Ab" "Bio Rad" France) and "The CombiBest HIV-1,2 AG/AT" ("Vector-Best" Novosibirsk). The sampling of 440 samples of blood serums of pregnant women from various medical institutions of Nizhnii Novgorod was analyzed. The results of the study demonstrated that FPSR were detected in all test-systems and at that spectrum of samples differed. The identical specificity of compared test-systems amounted to 98.64%. The alternative approach to FPSR to HIV issue under screening examinations of pregnant women was proposed. The proposed mode consisted of consistent application of two test-systems of fourth generation with different format of setup of reaction.
Comparison of Traditional and Reverse Syphilis Screening Algorithms in Medical Health Checkups.
Nah, Eun Hee; Cho, Seon; Kim, Suyoung; Cho, Han Ik; Chai, Jong Yil
2017-11-01
The syphilis diagnostic algorithms applied in different countries vary significantly depending on the local syphilis epidemiology and other considerations, including the expected workload, the need for automation in the laboratory and budget factors. This study was performed to investigate the efficacy of traditional and reverse syphilis diagnostic algorithms during general health checkups. In total, 1,000 blood specimens were obtained from 908 men and 92 women during their regular health checkups. Traditional screening and reverse screening were applied to the same specimens using automatic rapid plasma regain (RPR) and Treponema pallidum latex agglutination (TPLA) tests, respectively. Specimens that were reverse algorithm (TPLA) reactive, were subjected to a second treponemal test performed by using the chemiluminescent microparticle immunoassay (CMIA). Of the 1,000 specimens tested, 68 (6.8%) were reactive by reverse screening (TPLA) compared with 11 (1.1%) by traditional screening (RPR). The traditional algorithm failed to detect 48 specimens [TPLA(+)/RPR(-)/CMIA(+)]. The median TPLA cutoff index (COI) was higher in CMIA-reactive cases than in CMIA-nonreactive cases (90.5 vs 12.5 U). The reverse screening algorithm could detect the subjects with possible latent syphilis who were not detected by the traditional algorithm. Those individuals could be provided with opportunities for evaluating syphilis during their health checkups. The COI values of the initial TPLA test may be helpful in excluding false-positive TPLA test results in the reverse algorithm. © The Korean Society for Laboratory Medicine
Comparing diagnostic tests on benefit-risk.
Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott
2016-01-01
Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.
Advances in in vitro diagnostics in allergy, asthma, and immunology in 2012.
Renz, Harald
2013-12-01
Laboratory tests play an increasing role in risk assessment, diagnostics, and disease monitoring. Great advances have been achieved lately, particularly in the field of clinical immunology and allergy. These include neonatal screening of immunodeficiencies and asthma biomarkers and investigation into the role of recombinant allergens in in vitro testing. The latter area has implications for the diagnostics of food allergy, pollen-induced allergies, asthma, and insect allergies. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck
2015-05-14
Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .
Urinary free cortisol in the diagnosis of Cushing's syndrome: how useful?
Odeniyi, I A; Ifedayo, A O; Fasanmade, O A; Olufemi, A F
2013-01-01
Cushing's syndrome results from chronic exposure to excessive circulating levels of glucocorticoids. To confirm the clinical suspicion, biochemical tests are needed. These biochemical tests include the measurement of excess total endogenous cortisol secretion assessed by 24-hour urinary free cortisol (UFC), loss of the normal feedback of the hypothalamo-pituitary-adrenal axis assessed by suppressibility after dexamethasone testing, and disturbance of the normal circadian rhythm of cortisol secretion assessed by midnight serum or salivary cortisol. We searched the Medline, Pubmed, journal articles, WHO publications and reputable textbooks relating to Cushing's syndrome using publications from 1995 to 2011. UFC has been the classic screening test used to confirm hypercortisolemia as the first step in diagnostic work-up of Cushing's syndrome. Its long-term use in clinical practice has led to emergence of significant evidence regarding the utility of UFC in the diagnosis of Cushing's syndrome. UFC would have been a simple diagnostic tool to use but for the drawbacks in the sample collection, different laboratory methods of assay, not easily determined normal range. UFC use as a screening test is not strongly favoured because cortisol is not uniformly secreted during the day, and the increased prevalence of mild, preclinical or cyclic Cushing's syndrome. A very high level of UFC negates the need for other test procedures in patients with obvious symptoms and signs of Cushing's syndrome. We therefore suggest that UFC should be used with other screening tests for Cushing's syndrome to increase diagnostic yield.
Diagnostic guidelines for newborns who screen positive in newborn screening.
Kronn, David; Mofidi, Shideh; Braverman, Nancy; Harris, Katharine
2010-12-01
Recent expansion of the newborn screening panels has presented an interesting challenge to specialty care centers, especially the clinical genetics community. Some of the conditions in the core and secondary newborn screening panels have extremely variable clinical presentations; others are so rare that only a handful of newborns have been diagnosed with them to date (Region 4 Collaborative MS/MS project-http://region4genetics.org/msms_data_project/data_project_home.aspx). Definition of some disorders is problematic-does continued abnormality of the screening analyte constitute diagnosis or is further testing necessary? A work group of the New York Mid-Atlantic Consortium for Genetic and Newborn Screening Services (region 2), one of seven regional collaboratives funded by the Federal Health Resources and Services Administration and administered by the Maternal and Child Health Bureau (U22MC03956), has developed guidelines for the confirmation of diagnosis of the conditions in the newborn screening panels for use by the specialty care centers. The diagnostic guidelines are a work in progress and are being reviewed and revised regularly as our understanding of the newborn screened disorders improves. The aim is to make it a relevant guide for specialty care physicians and other healthcare professionals in the diagnostic workup of these patients.
Searle, Amelia K; Van Hooff, Miranda; McFarlane, Alexander C; Davies, Christopher E; Fairweather-Schmidt, A Kate; Hodson, Stephanie E; Benassi, Helen; Steele, Nicole
2015-03-01
Depression, alcohol use disorders and post-traumatic stress disorder (PTSD) are serious issues among military personnel due to their impact on operational capability and individual well-being. Several military forces screen for these disorders using scales including the Kessler Psychological Distress Scale (K10), Alcohol Use Disorders Identification Test (AUDIT), and Post-traumatic Stress Disorder Checklist (PCL). However, it is unknown whether established cutoffs apply to military populations. This study is the first to test the diagnostic accuracy of these three scales in a population-based military cohort. A large sample of currently-serving Australian Defence Force (ADF) Navy, Army and Air Force personnel (n = 24,481) completed the K10, AUDIT and PCL-C (civilian version). Then, a stratified sub-sample (n = 1798) completed a structured diagnostic interview detecting 30-day disorder. Data were weighted to represent the ADF population (n = 50,049). Receiver operating characteristic (ROC) analyses suggested all three scales had acceptable sensitivity and specificity, with areas under the curve from 0.75 to 0.93. AUDIT and K10 screening cutoffs closely paralleled established cutoffs, whereas the PCL-C screening cutoff resembled that recommended for US military personnel. These self-report scales represent a cost-effective and clinically-useful means of screening personnel for disorder. Military populations may need lower cutoffs than civilians to screen for PTSD. Copyright © 2014 John Wiley & Sons, Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, Veronica J.; ANU)
An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatorymore » test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.« less
Thomas, Sera-Melisa; Jeyaraman, Maya; Hodge, William G.; Hutnik, Cindy; Costella, John; Malvankar-Mehta, Monali S.
2014-01-01
Background Glaucoma is the leading cause of irreversible visual impairment in the world affecting 60.5 million people worldwide in 2010, which is expected to increase to approximately 79.6 million by 2020. Therefore, glaucoma screening is important to detect, diagnose, and treat patients at the earlier stages to prevent disease progression and vision loss. Teleglaucoma uses stereoscopic digital imaging to take ocular images, which are transmitted electronically to an ocular specialist. The purpose is to synthesize literature to evaluate teleglaucoma, its diagnostic accuracy, healthcare system benefits, and cost-effectiveness. Methods A systematic search was conducted to help locate published and unpublished studies. Studies which evaluate teleglaucoma as a screening device for glaucoma were included. A meta-analysis was conducted to provide estimates of diagnostic accuracy, diagnostic odds ratio, and the relative percentage of glaucoma cases detected. The improvements to healthcare service quality and cost data were assessed. Results Of 11237 studies reviewed, 45 were included. Our results indicated that, teleglaucoma is more specific and less sensitive than in-person examination. The pooled estimates of sensitivity was 0.832 [95% CI 0.770, 0.881] and specificity was 0.790 [95% CI 0.668, 0.876]. The relative odds of a positive screen test in glaucoma cases are 18.7 times more likely than a negative screen test in a non-glaucoma cases. Additionally, the mean cost for every case of glaucoma detected was $1098.67 US and of teleglaucoma per patient screened was $922.77 US. Conclusion Teleglaucoma can accurately discriminate between screen test results with greater odds for positive cases. It detects more cases of glaucoma than in-person examination. Both patients and the healthcare systems benefit from early detection, reduction in wait and travel times, increased specialist referral rates, and cost savings. Teleglaucoma is an effective screening tool for glaucoma specifically for remote and under-services communities. PMID:25479593
Thomas, Sera-Melisa; Jeyaraman, Maya M; Jeyaraman, Maya; Hodge, William G; Hutnik, Cindy; Costella, John; Malvankar-Mehta, Monali S
2014-01-01
Glaucoma is the leading cause of irreversible visual impairment in the world affecting 60.5 million people worldwide in 2010, which is expected to increase to approximately 79.6 million by 2020. Therefore, glaucoma screening is important to detect, diagnose, and treat patients at the earlier stages to prevent disease progression and vision loss. Teleglaucoma uses stereoscopic digital imaging to take ocular images, which are transmitted electronically to an ocular specialist. The purpose is to synthesize literature to evaluate teleglaucoma, its diagnostic accuracy, healthcare system benefits, and cost-effectiveness. A systematic search was conducted to help locate published and unpublished studies. Studies which evaluate teleglaucoma as a screening device for glaucoma were included. A meta-analysis was conducted to provide estimates of diagnostic accuracy, diagnostic odds ratio, and the relative percentage of glaucoma cases detected. The improvements to healthcare service quality and cost data were assessed. Of 11237 studies reviewed, 45 were included. Our results indicated that, teleglaucoma is more specific and less sensitive than in-person examination. The pooled estimates of sensitivity was 0.832 [95% CI 0.770, 0.881] and specificity was 0.790 [95% CI 0.668, 0.876]. The relative odds of a positive screen test in glaucoma cases are 18.7 times more likely than a negative screen test in a non-glaucoma cases. Additionally, the mean cost for every case of glaucoma detected was $1098.67 US and of teleglaucoma per patient screened was $922.77 US. Teleglaucoma can accurately discriminate between screen test results with greater odds for positive cases. It detects more cases of glaucoma than in-person examination. Both patients and the healthcare systems benefit from early detection, reduction in wait and travel times, increased specialist referral rates, and cost savings. Teleglaucoma is an effective screening tool for glaucoma specifically for remote and under-services communities.
Breast, prostate, and thyroid cancer screening tests and overdiagnosis.
Jung, Minsoo
The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.
Hygiene-therapists could be used to screen for dental caries and periodontal disease.
Richards, Derek
2015-12-01
A purposive sample of large NHS dental practices with a minimum of three surgeries employing at least one hygiene-therapist (HT) was taken. Asymptomatic patients attending for routine checkups who consented to the study underwent a screen by H-T for dental caries and periodontal disease (index test) followed by a screen by a general dental practitioner (reference test). Patients were recruited consecutively. H-Ts and dentists attended a compulsory training day, which covered recruitment, consenting, screening process, calibration using stock photographs and patient record form completion. Diagnostic threshold for caries was any tooth in the patient's mouth that showed evidence of frank cavitation or shadowing and opacity that would indicate dental caries into the dentine. The diagnostic threshold for periodontal disease was any pocket in the patient's mouth where the black-band of a basic periodontal examination (BPE) probe (3.5 to 5.5 mm) partially or totally disappeared (ie BPE code 3). The index test was compared with the reference test to determine true-positive, false-positive, false-negative and true-negative values. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic odds ratios are shown in Table 1. Eighteen hundred and ninety-nine patients consented to dental screening with 996 patients being randomly allocated to see the dentist first and 903 H-T first. The time interval between the index and reference test never exceeded 21 minutes. With the exception of two practices failing to collect data on smoking and dentures there were no missing results regarding the outcome of a positive or negative screening decision. No adverse events were reported. Mean screening time was five min 25 s for H-Ts and four min 26 s for dentists. Dentists identified 668 patients with caries (Prevalence of 0.35) while H-Ts classified 548 positive and correctly identified 1,047 of the 1,231 patients with no caries. Dentists identified 1074 patients with at least one pocket exceeding 3.5 mm in depth. Of these 935 were correctly identified by the H-Ts. For the 825 screened as negative by the dentist H-Ts correctly identified 621. The results suggest that hygiene-therapists could be used to screen for dental caries and periodontal disease. This has important ramifications for service design in public-funded health systems.
Lipasti, Seppo; Anttila, Ahti; Pamilo, Martti
2010-06-01
Limited information is available concerning differences in the radiological findings of women recalled for diagnostic work-up in digital mammography (DM) versus screen-film mammography (SFM) screening. To compare the radiological findings, their positive predictive values (PPVs) for cancer and other process indicators of DM screening performed by computed radiography (CR) technology and SFM screening in a population-based program. The material consisted of women, 50-59 years of age, who were invited for screening: 30 153 women with DM in 2007-2008 and 32 939 women with SFM in 1999-2000. The attendance rate was 77.7% (23 440) in the DM arm and 83.8% (27 593) in the SFM arm. In the DM arm, 1.71% of those screened (401) and in the SFM arm 1.59% (438) were recalled for further work-up. The images resulting in the recall were classified as: 1) tumor-like mass, 2) parenchymal distortion/asymmetry, 3) calcifications, and 4) combination of mass and calcifications. The distributions of the various radiological findings and their PPVs for cancer were compared in both study groups. The recall rates, cancer detection rates, test specificities, and PPVs of the DM and SFM groups were also compared. Women were recalled for diagnostic work-up most often due to tumor-like mass. It was more common in SFM (1.08% per woman screened) than in DM (0.93%). The second most common finding was parenchymal distortion and asymmetry, more often in DM (0.58%) than in SFM (0.37%). Calcifications were the third most common finding. DM exposed calcifications more often (0.49%) than SFM (0.26%). The PPVs for cancer of the recalls were higher in DM than in SFM in all subgroups of radiological findings. The test specificities were similar (DM 98.9%, SFM 98.8%). Significantly more cancers were detected by DM (cancer detection rate 0.623% per woman screened, n=146) than by SFM (cancer detection rate 0.406% per woman screened, n=112). The PPVs for cancer of all recalls for diagnostic work-up were significantly higher in DM (36%) than in SFM (26%). In DM women were recalled for diagnostic work-up more often for calcifications, parenchymal distortions, and asymmetries than in SFM. In the case of tumor-like masses, more women were recalled in SFM. DM detected more cancers than SFM, and the PPVs for cancer were higher in DM than in SFM in all subgroups of radiological findings.
Boot, Christopher; Toole, Barry; Johnson, Sarah J; Ball, Stephen; Neely, Dermot
2017-01-01
Background Measurement of plasma metanephrines is regarded as one of the best screening tests for phaeochromocytoma/paraganglioma. Current guidelines recommend that samples are ideally collected in the supine position after 30 min rest and interpreted using supine reference ranges, in order to optimize the diagnostic performance of the test. Current practice in our centre is to collect samples for plasma metanephrines from seated patients. The aim of the study was to determine, if seated sampling for plasma metanephrines provides acceptable diagnostic performance in our centre. Methods Clinical and laboratory data of 113 patients, gathered over a four-year period 2010-2014, were reviewed. All had undergone preoperative plasma metanephrines measurement and had postoperative histopathology confirmation or exclusion of phaeochromocytoma/paraganglioma. Results Of 113 patients included in the study, 40 had a histological diagnosis of phaeochromocytoma/paraganglioma. The remaining 73 patients had an alternative adrenal pathology. The diagnostic sensitivity of normetanephrine or metanephrine above the upper limit of our in-house seated reference range was 93%. However, excluding three cases of paraganglioma determined clinically and biochemically to be non-functional raised the sensitivity to 100%. Diagnostic specificity was 90%. Applying published supine reference ranges made no difference to diagnostic sensitivity in this group of patients but decreased diagnostic specificity to 75%. Conclusions While these data are derived from a relatively small study population, they demonstrate acceptable diagnostic performance for seated plasma metanephrines as a screening test for phaeochromocytoma/paraganglioma. These data highlight a high diagnostic sensitivity for plasma metanephrines with seated sampling in our centre.
The PHQ-PD as a Screening Tool for Panic Disorder in the Primary Care Setting in Spain
Wood, Cristina Mae; Ruíz-Rodríguez, Paloma; Tomás-Tomás, Patricia; Gracia-Gracia, Irene; Dongil-Collado, Esperanza; Iruarrizaga, M. Iciar
2016-01-01
Introduction Panic disorder is a common anxiety disorder and is highly prevalent in Spanish primary care centres. The use of validated tools can improve the detection of panic disorder in primary care populations, thus enabling referral for specialized treatment. The aim of this study is to determine the accuracy of the Patient Health Questionnaire-Panic Disorder (PHQ-PD) as a screening and diagnostic tool for panic disorder in Spanish primary care centres. Method We compared the psychometric properties of the PHQ-PD to the reference standard, the Structured Clinical Interview for DSM-IV Axis I Disorders (SCID-I) interview. General practitioners referred 178 patients who completed the entire PHQ test, including the PHQ-PD, to undergo the SCID-I. The sensitivity, specificity, positive and negative predictive values and positive and negative likelihood ratios of the PHQ-PD were assessed. Results The operating characteristics of the PHQ-PD are moderate. The best cut-off score was 5 (sensitivity .77, specificity .72). Modifications to the questionnaire's algorithms improved test characteristics (sensitivity .77, specificity .72) compared to the original algorithm. The screening question alone yielded the highest sensitivity score (.83). Conclusion Although the modified algorithm of the PHQ-PD only yielded moderate results as a diagnostic test for panic disorder, it was better than the original. Using only the first question of the PHQ-PD showed the best psychometric properties (sensitivity). Based on these findings, we suggest the use of the screening questions for screening purposes and the modified algorithm for diagnostic purposes. PMID:27525977
Gómez-Banoy, Nicolás; Cuevas, Virginia; Soler, Fernando; Pineda, Maria Fernanda; Mockus, Ismena
2017-01-01
This cross sectional study intended to evaluate two bedside tests (Neuropad and VibraTip) as screening tools for distal symmetrical polyneuropathy (DSPN) in Latin American patients with type 2 diabetes mellitus (T2D). Ninety-three Colombian patients diagnosed with T2D were recruited. Anthropometric variables, glycemic control parameters, lipid profile and renal function were assessed for each patient. DSPN was defined by a Michigan Neuropathy Screening Instrument (MNSI) clinical score greater than 2. Both Neuropad and Vibratip tests were applied to each patient. Contingency analyses were performed to evaluate the diagnostic power of both tools. The prevalence of DSPN determined clinically by MNSI was 25.8%. DSPN in these patients was associated with age, worsening renal function, and insulin treatment. The sensitivity and specificity of the Neuropad test for DSPN was 66.6% and 63% respectively. Its negative predictive value (NPV) was 84.6%. The VibraTip test exhibited a sensitivity of 54.1% and specificity of 91.3%, with a NPV of 85.1%. Neuropad and VibraTip are reliable screening tools for DSPN in Latin American population. VibraTip presents a considerable diagnostic power for DSPN in this population. Further studies regarding the cost-effectiveness of these tools in clinical practice are needed.
Nekouei, Omid; Durocher, Jean; Keefe, Greg
2016-07-01
This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs.
Nekouei, Omid; Durocher, Jean; Keefe, Greg
2016-01-01
This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469
Why hasn't this patient been screened for colon cancer? An Iowa Research Network study.
Levy, Barcey T; Nordin, Terri; Sinift, Suzanne; Rosenbaum, Marcy; James, Paul A
2007-01-01
Less than half of eligible Americans have been screened for colorectal cancer (CRC). The objective of this study was to describe physicians' reasons for screening or not screening specific patients for CRC and their approach to CRC testing discussions. This study used mixed-methods. Physicians described their reasons for screening or not screening 6 randomly chosen patients who were eligible for CRC screening (3 screened and 3 not screened) whose CRC testing status was ascertained by medical record review. Verbatim transcripts from physicians responding to structured interview questions were used to identify themes. Specific elements of discussion were examined for their association with each physician's screening rate. Fifteen randomly chosen Iowa family physicians from the Iowa Research Network stratified by privileges to perform colonoscopy, flexible sigmoidoscopy, or neither procedure dictated the reasons why 43 patients were screened and 40 patients were not screened. Reasons patients were not up to date fell into 2 major categories: (1) no discussion by physician (50%) and (2) patient refusal (43%). Reasons for no discussion included lack of opportunity, assessment that cost would be prohibitive, distraction by other life issues/health problems, physician forgetfulness, and expected patient refusal. Patients declined because of cost, lack of interest, autonomy, other life issues, fear of screening, and lack of symptoms. Patients who were up to date received (1) diagnostic testing (for previous colon pathology or symptoms; 56%) or (2) asymptomatic screening (44%). Physicians who were more adamant about screening had higher screening rates (P<.05; Wilcoxon rank sum). Physicians framed their recommendations differently ("I recommend" vs "They recommend"), with lower screening rates among physicians who used "they recommend" (P=.05; Wilcoxon rank sum). Reasons many patients remain unscreened for CRC include (1) factors related to the health care system, patient, and physician that impede or prevent discussion; (2) patient refusal; and (3) the focus on diagnostic testing. Strategies to improve screening might include patient and physician education about the rationale for screening, universal coverage for health maintenance exams, and development of effective tracking and reminder systems. The words physicians choose to frame their recommendations are important and should be explored further.
Clinical applications of preimplantation genetic testing.
Brezina, Paul R; Kutteh, William H
2015-02-19
Genetic diagnostic technologies are rapidly changing the way medicine is practiced. Preimplantation genetic testing is a well established application of genetic testing within the context of in vitro fertilization cycles. It involves obtaining a cell(s) from a developing embryo in culture, which is then subjected to genetic diagnostic analysis; the resulting information is used to guide which embryos are transferred into the uterus. The potential applications and use of this technology have increased in recent years. Experts agree that preimplantation genetic diagnosis is clinically appropriate for many known genetic disorders. However, some applications of such testing, such as preimplantation genetic screening for aneuploidy, remain controversial. Clinical data suggest that preimplantation genetic screening may be useful, but further studies are needed to quantify the size of the effect and who would benefit most. © BMJ Publishing Group Ltd 2015.
Wang, Haili; Tso, Victor; Wong, Clarence; Sadowski, Dan; Fedorak, Richard N
2014-03-20
Adenomatous polyps are precursors of colorectal cancer; their detection and removal is the goal of colon cancer screening programs. However, fecal-based methods identify patients with adenomatous polyps with low levels of sensitivity. The aim or this study was to develop a highly accurate, prototypic, proof-of-concept, spot urine-based diagnostic test using metabolomic technology to distinguish persons with adenomatous polyps from those without polyps. Prospective urine and stool samples were collected from 876 participants undergoing colonoscopy examination in a colon cancer screening program, from April 2008 to October 2009 at the University of Alberta. Colonoscopy reference standard identified 633 participants with no colonic polyps and 243 with colonic adenomatous polyps. One-dimensional nuclear magnetic resonance spectra of urine metabolites were analyzed to define a diagnostic metabolomic profile for colonic adenomas. A urine metabolomic diagnostic test for colonic adenomatous polyps was established using 67% of the samples (un-blinded training set) and validated using the other 33% of the samples (blinded testing set). The urine metabolomic diagnostic test's specificity and sensitivity were compared with those of fecal-based tests. Using a two-component, orthogonal, partial least-squares model of the metabolomic profile, the un-blinded training set identified patients with colonic adenomatous polyps with 88.9% sensitivity and 50.2% specificity. Validation using the blinded testing set confirmed sensitivity and specificity values of 82.7% and 51.2%, respectively. Sensitivities of fecal-based tests to identify colonic adenomas ranged from 2.5 to 11.9%. We describe a proof-of-concept spot urine-based metabolomic diagnostic test that identifies patients with colonic adenomatous polyps with a greater level of sensitivity (83%) than fecal-based tests.
Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C
2007-01-01
After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.
Memória, Cláudia M; Yassuda, Mônica S; Nakano, Eduardo Y; Forlenza, Orestes V
2014-05-07
ABSTRACT Background: The Computer-Administered Neuropsychological Screen for Mild Cognitive Impairment (CANS-MCI) is a computer-based cognitive screening instrument that involves automated administration and scoring and immediate analyses of test sessions. The objective of this study was to translate and culturally adapt the Brazilian Portuguese version of the CANS-MCI (CANS-MCI-BR) and to evaluate its reliability and validity for the diagnostic screening of MCI and dementia due to Alzheimer's disease. Methods: The test was administered to 97 older adults (mean age 73.41 ± 5.27 years) with at least four years of formal education (mean education 12.23 ± 4.48 years). Participants were classified into three diagnostic groups according to global cognitive status (normal controls, n = 41; MCI, n = 35; AD, n = 21) based on clinical data and formal neuropsychological assessments. Results: The results indicated high internal consistency (Cronbach's α = 0.77) in the total sample. Three-month test-retest reliability correlations were significant and robust (0.875; p < 0.001). A moderate level of concurrent validity was attained relative to the screening test for MCI (MoCA test, r = 0.76, p < 0.001). Confirmatory factor analysis supported the three-factor model of the original test, i.e., memory, language/spatial fluency, and executive function/mental control. Goodness of fit indicators were strong (Bentler Comparative Fit Index = 0.96, Root Mean Square Error of Approximation = 0.09). Receiver operating characteristic curve analyses suggested high sensitivity and specificity (81% and 73% respectively) to screen for possible MCI cases. Conclusions: The CANS-MCI-BR maintains adequate psychometric characteristics that render it suitable to identify elderly adults with probable cognitive impairment to whom a more extensive evaluation by formal neuropsychological tests may be required.
Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin
2014-03-01
To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.
Brodey, Benjamin; Purcell, Susan E; Rhea, Karen; Maier, Philip; First, Michael; Zweede, Lisa; Sinisterra, Manuela; Nunn, M Brad; Austin, Marie-Paule; Brodey, Inger S
2018-03-23
The Structured Clinical Interview for DSM (SCID) is considered the gold standard assessment for accurate, reliable psychiatric diagnoses; however, because of its length, complexity, and training required, the SCID is rarely used outside of research. This paper aims to describe the development and initial validation of a Web-based, self-report screening instrument (the Screening Assessment for Guiding Evaluation-Self-Report, SAGE-SR) based on the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) and the SCID-5-Clinician Version (CV) intended to make accurate, broad-based behavioral health diagnostic screening more accessible within clinical care. First, study staff drafted approximately 1200 self-report items representing individual granular symptoms in the diagnostic criteria for the 8 primary SCID-CV modules. An expert panel iteratively reviewed, critiqued, and revised items. The resulting items were iteratively administered and revised through 3 rounds of cognitive interviewing with community mental health center participants. In the first 2 rounds, the SCID was also administered to participants to directly compare their Likert self-report and SCID responses. A second expert panel evaluated the final pool of items from cognitive interviewing and criteria in the DSM-5 to construct the SAGE-SR, a computerized adaptive instrument that uses branching logic from a screener section to administer appropriate follow-up questions to refine the differential diagnoses. The SAGE-SR was administered to healthy controls and outpatient mental health clinic clients to assess test duration and test-retest reliability. Cutoff scores for screening into follow-up diagnostic sections and criteria for inclusion of diagnoses in the differential diagnosis were evaluated. The expert panel reduced the initial 1200 test items to 664 items that panel members agreed collectively represented the SCID items from the 8 targeted modules and DSM criteria for the covered diagnoses. These 664 items were iteratively submitted to 3 rounds of cognitive interviewing with 50 community mental health center participants; the expert panel reviewed session summaries and agreed on a final set of 661 clear and concise self-report items representing the desired criteria in the DSM-5. The SAGE-SR constructed from this item pool took an average of 14 min to complete in a nonclinical sample versus 24 min in a clinical sample. Responses to individual items can be combined to generate DSM criteria endorsements and differential diagnoses, as well as provide indices of individual symptom severity. Preliminary measures of test-retest reliability in a small, nonclinical sample were promising, with good to excellent reliability for screener items in 11 of 13 diagnostic screening modules (intraclass correlation coefficient [ICC] or kappa coefficients ranging from .60 to .90), with mania achieving fair test-retest reliability (ICC=.50) and other substance use endorsed too infrequently for analysis. The SAGE-SR is a computerized adaptive self-report instrument designed to provide rigorous differential diagnostic information to clinicians. ©Benjamin Brodey, Susan E Purcell, Karen Rhea, Philip Maier, Michael First, Lisa Zweede, Manuela Sinisterra, M Brad Nunn, Marie-Paule Austin, Inger S Brodey. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 23.03.2018.
ERIC Educational Resources Information Center
Youngstrom, Eric A.; Findling, Robert L.; Calabrese, Joseph R.; Gracious, Barbara L.; Demeter, Christine; DelPorto Bedoya, Denise; Price, Megan
2004-01-01
Objective: To compare the diagnostic efficiency of six index tests as predictors of juvenile bipolar disorder in two large outpatient samples, aged 5 to 10 and 11 to 17 years, gathered from 1997 to 2002. Method: DSM-IV diagnosis was based on a semistructured diagnostic interview (Schedule for Affective Disorders and Schizophrenia for School-Age…
Darnell, Julie S.; Ko, Naomi; Snyder, Fred; Paskett, Electra D.; Wells, Kristen J.; Whitley, Elizabeth M.; Griggs, Jennifer J.; Karnad, Anand; Young, Heather; Warren-Mears, Victoria; Simon, Melissa A.; Calhoun, Elizabeth
2016-01-01
Patient navigation is emerging as a standard in breast cancer care delivery, yet multi-site data on the impact of navigation at reducing delays along the continuum of care are lacking. The purpose of this study was to determine the effect of navigation on reaching diagnostic resolution at specific time points after an abnormal breast cancer screening test among a national sample. A prospective meta-analysis estimated the adjusted odds of achieving timely diagnostic resolution at 60, 180, and 365 days. Exploratory analyses were conducted on the pooled sample to identify which groups had the most benefit from navigation. Clinics from six medical centers serving vulnerable populations participated in the Patient Navigation Research Program. Women with an abnormal breast cancer screening test between 2007 and 2009 were included and received the patient navigation intervention or usual care. Patient navigators worked with patients and their care providers to address patient-specific barriers to care to prevent delays in diagnosis. A total of 4675 participants included predominantly racial/ethnic minorities (74 %) with public insurance (40 %) or no insurance (31 %). At 60 days and 180 days, there was no statistically significant effect of navigation on achieving timely diagnostic care, but a benefit of navigation was seen at 365 days (aOR 2.12, CI 1.36–3.29). We found an equal benefit of navigation across all groups, regardless of race/ethnicity, language, insurance status, and type of screening abnormality. Patient navigation resulted in more timely diagnostic resolution at 365 days among a diverse group of minority, low-income women with breast cancer screening abnormalities. PMID:27432417
Battaglia, Tracy A; Darnell, Julie S; Ko, Naomi; Snyder, Fred; Paskett, Electra D; Wells, Kristen J; Whitley, Elizabeth M; Griggs, Jennifer J; Karnad, Anand; Young, Heather; Warren-Mears, Victoria; Simon, Melissa A; Calhoun, Elizabeth
2016-08-01
Patient navigation is emerging as a standard in breast cancer care delivery, yet multi-site data on the impact of navigation at reducing delays along the continuum of care are lacking. The purpose of this study was to determine the effect of navigation on reaching diagnostic resolution at specific time points after an abnormal breast cancer screening test among a national sample. A prospective meta-analysis estimated the adjusted odds of achieving timely diagnostic resolution at 60, 180, and 365 days. Exploratory analyses were conducted on the pooled sample to identify which groups had the most benefit from navigation. Clinics from six medical centers serving vulnerable populations participated in the Patient Navigation Research Program. Women with an abnormal breast cancer screening test between 2007 and 2009 were included and received the patient navigation intervention or usual care. Patient navigators worked with patients and their care providers to address patient-specific barriers to care to prevent delays in diagnosis. A total of 4675 participants included predominantly racial/ethnic minorities (74 %) with public insurance (40 %) or no insurance (31 %). At 60 days and 180 days, there was no statistically significant effect of navigation on achieving timely diagnostic care, but a benefit of navigation was seen at 365 days (aOR 2.12, CI 1.36-3.29). We found an equal benefit of navigation across all groups, regardless of race/ethnicity, language, insurance status, and type of screening abnormality. Patient navigation resulted in more timely diagnostic resolution at 365 days among a diverse group of minority, low-income women with breast cancer screening abnormalities. Trial registrations clinicaltrials.gov Identifiers: NCT00613275, NCT00496678, NCT00375024, NCT01569672.
Markossian, Talar W.; Darnell, Julie S.; Calhoun, Elizabeth A.
2012-01-01
Background We evaluated the efficacy of a Chicago-based cancer patient navigation program developed to increase the proportion of patients reaching diagnostic resolution and reduce the time from abnormal screening test to definitive diagnostic resolution. Methods Women with an abnormal breast (n=352) or cervical (n=545) cancer screening test were recruited for the quasi-experimental study. Navigation subjects originated from five federally qualified health center sites and one safety net hospital. Records-based concurrent control subjects were selected from 20 sites. Control sites had similar characteristics to the navigated sites in terms of patient volume, racial/ethnic composition, and payor mix. Mixed-effects logistic regression and Cox proportional hazard regression analyses were conducted to compare navigation and control patients reaching diagnostic resolution by 60 days and time to resolution, adjusting for demographic covariates and site. Results Compared to controls, the breast navigation group had shorter time to diagnostic resolution (aHR=1.65, CI=1.20–2.28) and the cervical navigation group had shorter time to diagnostic resolution for those who resolved after 30 days (aHR= 2.31, CI=1.75–3.06), with no difference before 30 days (aHR= 1.42, CI=0.83–2.43). Variables significantly associated with longer time to resolution for breast cancer screening abnormalities were being older, never partnered, abnormal mammogram and BI-RADS 3, and being younger and Black for cervical abnormalities. Conclusions Patient navigation reduces time from abnormal cancer finding to definitive diagnosis in underserved women. Impact Results support efforts to use patient navigation as a strategy to reduce cancer disparities among socioeconomically disadvantaged women. PMID:23045544
Markossian, Talar W; Darnell, Julie S; Calhoun, Elizabeth A
2012-10-01
We evaluated the efficacy of a Chicago-based cancer patient navigation program developed to increase the proportion of patients reaching diagnostic resolution and reduce the time from abnormal screening test to definitive diagnostic resolution. Women with an abnormal breast (n = 352) or cervical (n = 545) cancer screening test were recruited for the quasi-experimental study. Navigation subjects originated from five federally qualified health center sites and one safety net hospital. Records-based concurrent control subjects were selected from 20 sites. Control sites had similar characteristics to the navigated sites in terms of patient volume, racial/ethnic composition, and payor mix. Mixed-effects logistic regression and Cox proportional hazard regression analyses were conducted to compare navigation and control patients reaching diagnostic resolution by 60 days and time to resolution, adjusting for demographic covariates and site. Compared with controls, the breast navigation group had shorter time to diagnostic resolution (aHR = 1.65, CI = 1.20-2.28) and the cervical navigation group had shorter time to diagnostic resolution for those who resolved after 30 days (aHR = 2.31, CI = 1.75-3.06), with no difference before 30 days (aHR = 1.42, CI = 0.83-2.43). Variables significantly associated with longer time to resolution for breast cancer screening abnormalities were being older, never partnered, abnormal mammogram and BI-RADS 3, and being younger and Black for cervical abnormalities. Patient navigation reduces time from abnormal cancer finding to definitive diagnosis in underserved women. Results support efforts to use patient navigation as a strategy to reduce cancer disparities among socioeconomically disadvantaged women. 2012 AACR
Maternal Plasma DNA and RNA Sequencing for Prenatal Testing.
Tamminga, Saskia; van Maarle, Merel; Henneman, Lidewij; Oudejans, Cees B M; Cornel, Martina C; Sistermans, Erik A
2016-01-01
Cell-free DNA (cfDNA) testing has recently become indispensable in diagnostic testing and screening. In the prenatal setting, this type of testing is often called noninvasive prenatal testing (NIPT). With a number of techniques, using either next-generation sequencing or single nucleotide polymorphism-based approaches, fetal cfDNA in maternal plasma can be analyzed to screen for rhesus D genotype, common chromosomal aneuploidies, and increasingly for testing other conditions, including monogenic disorders. With regard to screening for common aneuploidies, challenges arise when implementing NIPT in current prenatal settings. Depending on the method used (targeted or nontargeted), chromosomal anomalies other than trisomy 21, 18, or 13 can be detected, either of fetal or maternal origin, also referred to as unsolicited or incidental findings. For various biological reasons, there is a small chance of having either a false-positive or false-negative NIPT result, or no result, also referred to as a "no-call." Both pre- and posttest counseling for NIPT should include discussing potential discrepancies. Since NIPT remains a screening test, a positive NIPT result should be confirmed by invasive diagnostic testing (either by chorionic villus biopsy or by amniocentesis). As the scope of NIPT is widening, professional guidelines need to discuss the ethics of what to offer and how to offer. In this review, we discuss the current biochemical, clinical, and ethical challenges of cfDNA testing in the prenatal setting and its future perspectives including novel applications that target RNA instead of DNA. © 2016 Elsevier Inc. All rights reserved.
Perrot, Serge; Peixoto, Mariana; Dieudé, Philippe; Hachulla, Eric; Avouac, Jerome; Ottaviani, Sebastien; Allanore, Yannick
2017-01-01
Fibromyalgia (FM) may occur with rheumatoid arthritis (RA) and systemic sclerosis (SSc), and debate remains about its diagnosis. We aimed to use three FM tools (a screening tool (FiRST), diagnostic criteria (ACR 1990 and revised 2010), to compare FM prevalence between RA and SSc patients, to describe the phenotypes of patients with comorbid FM, and to analyze links between FM and secondary Sjögren's syndrome (SS). Consecutive adult patients with confirmed RA or SSc from four university hospitals were tested with the three FM tools. FiRST detected FM in 22.6% of the 172 RA patients, with confirmation in 22.1% (ACR1990) and 19.1% (ACR2010). ACR1990FM+ RA patients had more diffuse pain, whereas ACR2010FM+ RA patients had higher BMI and pain intensity, more diffuse pain, active disease, disability, and associated SS. FiRST detected FM in 27.8% of the 122 SSc patients, with confirmation in 30.3% (ACR1990) and 23.7% (ACR2010). ACR1990FM+ SSc patients had greater disability and pain intensity, and more diffuse pain, whereas ACR2010FM+ SSc patients had higher BMI, pain intensity, more disability and diffuse pain, and associated SS. Correlations between FM diagnostic and screening tool results were modest in both conditions. Secondary SS was associated with comorbid FM. The prevalence of FM is high in SSc and RA, whatever the FM diagnostic tool used. Secondary SS is associated with FM in both RA and SSc. The revised ACR 2010 FM criteria and FiRST screening tool reveal specific phenotypes potentially useful for improving disease management.
2012-01-01
Background Routine cytomegalovirus (CMV) screening during pregnancy is not recommended in the United States and the extent to which it is performed is unknown. Using a medical claims database, we computed rates of CMV-specific testing among pregnant women. Methods We used medical claims from the 2009 Truven Health MarketScan® Commercial databases. We computed CMV-specific testing rates using CPT codes. Results We identified 77,773 pregnant women, of whom 1,668 (2%) had a claim for CMV-specific testing. CMV-specific testing was significantly associated with older age, Northeast or urban residence, and a diagnostic code for mononucleosis. We identified 44 women with a diagnostic code for mononucleosis, of whom 14% had CMV-specific testing. Conclusions Few pregnant women had CMV-specific testing, suggesting that screening for CMV infection during pregnancy is not commonly performed. In the absence of national surveillance for CMV infections during pregnancy, healthcare claims are a potential source for monitoring practices of CMV-specific testing. PMID:23198949
Gibbons, Robert D; Hooker, Giles; Finkelman, Matthew D; Weiss, David J; Pilkonis, Paul A; Frank, Ellen; Moore, Tara; Kupfer, David J
2013-07-01
To develop a computerized adaptive diagnostic screening tool for depression that decreases patient and clinician burden and increases sensitivity and specificity for clinician-based DSM-IV diagnosis of major depressive disorder (MDD). 656 individuals with and without minor and major depression were recruited from a psychiatric clinic and a community mental health center and through public announcements (controls without depression). The focus of the study was the development of the Computerized Adaptive Diagnostic Test for Major Depressive Disorder (CAD-MDD) diagnostic screening tool based on a decision-theoretical approach (random forests and decision trees). The item bank consisted of 88 depression scale items drawn from 73 depression measures. Sensitivity and specificity for predicting clinician-based Structured Clinical Interview for DSM-IV Axis I Disorders diagnoses of MDD were the primary outcomes. Diagnostic screening accuracy was then compared to that of the Patient Health Questionnaire-9 (PHQ-9). An average of 4 items per participant was required (maximum of 6 items). Overall sensitivity and specificity were 0.95 and 0.87, respectively. For the PHQ-9, sensitivity was 0.70 and specificity was 0.91. High sensitivity and reasonable specificity for a clinician-based DSM-IV diagnosis of depression can be obtained using an average of 4 adaptively administered self-report items in less than 1 minute. Relative to the currently used PHQ-9, the CAD-MDD dramatically increased sensitivity while maintaining similar specificity. As such, the CAD-MDD will identify more true positives (lower false-negative rate) than the PHQ-9 using half the number of items. Inexpensive (relative to clinical assessment), efficient, and accurate screening of depression in the settings of primary care, psychiatric epidemiology, molecular genetics, and global health are all direct applications of the current system. © Copyright 2013 Physicians Postgraduate Press, Inc.
78 FR 45201 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-26
... design with pre- and post-tests involving a total of six states: three CRCCP grantee states (Alabama... be used to fund the provision of screening and diagnostic tests. Additional program activities such...
What Health Problems Can Develop during Pregnancy?
... glucose challenge screening test around 24 to 28 weeks of pregnancy, followed by a diagnostic test called ... of protein in the urine after the 20th week of pregnancy), and cesarean birth . Treatment includes controlling ...
Diagnostic value of screening tests in subgroups of women with recurrent pregnancy loss.
Guzel, Ali Irfan; Erkılınç, Selçuk; Özer, Irfan; Celik, Yusuf; Yılmaz, Nafiye; Doğanay, Melike
2015-03-01
To evaluate the diagnostic value of screening laboratory tests in women who had recurrent pregnancy loss (RPL). A total of 252 women with RPL managed in our tertiary referral research and education hospital were included in the study. Risk factors recorded involved age, gravidity, parity, number of prior live births, number of pregnancy losses, and thrombophlia tests. The cases were divided into three different groups and each group was analyzed separately. There was no statistically significant difference between the first and second groups in terms of clinical and laboratory parameters (p > 0.05). In the third group, there was a statistically significant difference among cases in terms of parity, gravidity, number of pregnancy losses, serum AT III levels, APCR, and age of the women. According to the logistic regression model, odds ratios (95% CI) were 6.116 (3.797-9.852), 5.665 (2.657-12.079), 4.763 (3.099-7.321), 4.729 (3.080-7.260), 2.820 (1.836-4.333), and 1.911 (1.232-2.965), respectively. We do not recommend the screening of all women with RPL, but in women with high parity and those who had prior live birth pregnancies, increased AT III, and APCR may be diagnostic markers for subsequent pregnancy loss.
Adu-Gyasi, Dennis; Asante, Kwaku Poku; Newton, Sam; Dosoo, David; Amoako, Sabastina; Adjei, George; Amoako, Nicholas; Ankrah, Love; Tchum, Samuel Kofi; Mahama, Emmanuel; Agyemang, Veronica; Kayan, Kingsley; Owusu-Agyei, Seth
2015-01-01
Background Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most widespread enzyme defect that can result in red cell breakdown under oxidative stress when exposed to certain medicines including antimalarials. We evaluated the diagnostic accuracy of CareStart G6PD deficiency Rapid Diagnostic Test (RDT) as a point-of-care tool for screening G6PD deficiency. Methods A cross-sectional study was conducted among 206 randomly selected and consented participants from a group with known G6PD deficiency status between February 2013 and June 2013. A maximum of 1.6ml of capillary blood samples were used for G6PD deficiency screening using CareStart G6PD RDT and Trinity qualitative with Trinity quantitative methods as the “gold standard”. Samples were also screened for the presence of malaria parasites. Data entry and analysis were done using Microsoft Access 2010 and Stata Software version 12. Kintampo Health Research Centre Institutional Ethics Committee granted ethical approval. Results The sensitivity (SE) and specificity (SP) of CareStart G6PD deficiency RDT was 100% and 72.1% compared to Trinity quantitative method respectively and was 98.9% and 96.2% compared to Trinity qualitative method. Malaria infection status had no significant (P=0.199) change on the performance of the G6PD RDT test kit compared to the “gold standard”. Conclusions The outcome of this study suggests that the diagnostic performance of the CareStart G6PD deficiency RDT kit was high and it is acceptable at determining the G6PD deficiency status in a high malaria endemic area in Ghana. The RDT kit presents as an attractive tool for point-of-care G6PD deficiency for rapid testing in areas with high temperatures and less expertise. The CareStart G6PD deficiency RDT kit could be used to screen malaria patients before administration of the fixed dose primaquine with artemisinin-based combination therapy. PMID:25885097
Hoyer, Annika; Kuss, Oliver
2018-05-01
Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared.
Backscatter from metal surfaces in diagnostic radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kodera, Y.; Schmidt, R.A.; Chan, H.P.
Backscatter from four commonly used metals (aluminum, lead, copper, and iron) was measured under diagnostic imaging conditions, using screen-film systems as detectors. The results indicate that for an 80-kV filtered beam and Par Speed/XRP system, backscatter increases as aluminum (Al) thickness increases until it reaches a plateau of approximately 12% at 50 mm Al. The amount of backscatter depends strongly on the screen used, possibly due to their attenuation and energy response. Backscatter from aluminum was significantly greater than that from the other metals tested.
Dybek, Inga; Bischof, Gallus; Grothues, Janina; Reinhardt, Susa; Meyer, Christian; Hapke, Ulfert; John, Ulrich; Broocks, Andreas; Hohagen, Fritz; Rumpf, Hans-Jürgen
2006-05-01
Our goal was to analyze the retest reliability and validity of the Alcohol Use Disorders Identification Test (AUDIT) in a primary-care setting and recommend a cut-off value for the different alcohol-related diagnoses. Participants recruited from general practices (GPs) in two northern German cities received the AUDIT, which was embedded in a health-risk questionnaire. In total, 10,803 screenings were conducted. The retest reliability was tested on a subsample of 99 patients, with an intertest interval of 30 days. Sensitivity and specificity at a number of different cut-off values were estimated for the sample of alcohol consumers (n=8237). For this study, 1109 screen-positive patients received a diagnostic interview. Individuals who scored less than five points in the AUDIT and also tested negative in a second alcohol-related screen were defined as "negative" (n=6003). This definition was supported by diagnostic interviews of 99 screen-negative patients from which no false negatives could be detected. As the gold standard for detection of an alcohol-use disorder (AUD), we used the Munich-Composite International Diagnostic Interview (MCIDI), which is based on Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria. On the item level, the reliability, measured by the intraclass correlation coefficient (ICC), ranged between .39 (Item 9) and .98 (Item 10). For the total score, the ICC was .95. For cut-off values of eight points and five points, 87.5% and 88.9%, respectively, of the AUDIT-positives, and 98.9% and 95.1%, respectively, of the AUDIT-negatives were identically identified at retest, with kappa = .86 and kappa = .81. At the cut-off value of five points, we determined good combinations of sensitivity and specificity for the following diagnoses: alcohol dependence (sensitivity and specificity of .97 and .88, respectively), AUD (.97 and .92), and AUD and/or at-risk consumption (.97 and .91). Embedded in a health-risk questionnaire in primary-care settings, the AUDIT is a reliable and valid screening instrument to identify at-risk drinkers and patients with an AUD. Our findings strongly suggest a lowering of the recommended cut-off value of eight points.
Vlahiotis, Anna; Griffin, Brian; Stavros, A Thomas; Margolis, Jay
2018-01-01
Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam. To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures. Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy) other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event), with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes. The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients), 6,987,399 breast ultrasounds (42.4% of patients), and 1,585,856 biopsies (10.3% of patients). Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD) costs for diagnostic mammograms of US$349 ($493), ultrasounds US$132 ($134), and biopsies US$1,938 ($2,343) contributed US$3.05 billion, US$0.92 billion, and US$3.07 billion, respectively, to annual diagnostic breast expenditures estimated at US$7.91 billion. The volume and expense of additional breast diagnostic testing, estimated at US$7.91 billion annually, underscores the need for technological improvements in the breast diagnostic landscape.
Corbett, E. L.; MacPherson, P.
2014-01-01
SUMMARY Twenty years of sky-high tuberculosis (TB) incidence rates and high TB mortality in high human immunodeficiency virus (HIV) prevalence countries have so far not been matched by the same magnitude or breadth of responses as seen in malaria or HIV programmes. Instead, recommendations have been narrowly focused on people presenting to health facilities for investigation of TB symptoms, or for HIV testing and care. However, despite the recent major investment and scale-up of TB and HIV services, undiagnosed TB remains highly prevalent at community level, implying that diagnosis of TB remains slow and incomplete. This maintains high transmission rates and exposes people living with HIV to high rates of morbidity and mortality. More intensive use of TB screening, with broader definitions of target populations, expanded indications for screening both inside and outside of health facilities, and appropriate selection of new diagnostic tools, offers the prospect of rapidly improving population-level control of TB. Diagnostic accuracy of suitable (high throughput) algorithms remains the major barrier to realising this goal. In the present study, we review the evidence available to guide expanded TB screening in HIV-prevalent settings, ideally through combined TB-HIV interventions that provide screening for both TB and HIV, and maximise entry to HIV and TB care and prevention. Ideally, we would systematically test, treat and prevent TB and HIV comprehensively, offering both TB and HIV screening to all health facility attendees, TB households and all adults in the highest risk communities. However, we are still held back by inadequate diagnostics, financing and paucity of population-impact data. Relevant contemporary research showing the high need for potential gains, and pitfalls from expanded and intensified TB screening in high HIV prevalence settings are discussed in this review. PMID:23928165
Primary ciliary dyskinesia: improving the diagnostic approach
Leigh, Margaret W.; Zariwala, Maimoona A.; Knowles, Michael R.
2009-01-01
Purpose of review The diagnosis of primary ciliary dyskinesia (PCD) has relied on analysis of ciliary motility and ultrastructure; however, these tests are not readily available and have not been standardized. Consequently, the diagnosis of PCD may be delayed or missed or made incorrectly. This review outlines the potential utility of new diagnostic tests, including measurement of nasal nitric oxide (NO) production and systematic analysis for mutations in gene encoding ciliary proteins. Recent findings Clinical manifestations of PCD have been expanded to include neonatal respiratory distress and heterotaxy. Measurement of nasal NO has emerged as a useful screening test for PCD based on the very low levels in PCD (approximately 1/10 of normal values). Genetic testing is emerging for PCD and demonstrates extensive genetic heterogeneity. Some genes and gene mutations involved in PCD have been defined. Approximately one third of PCD cases have identifiable gene mutations in one of 6 different genes. An international effort is focused on defining PCD-causing defects in other genes. Summary The incorporation of nasal NO measurement as a screening test to define probable PCD cases and gene mutation analysis to make a definitive diagnosis of PCD should enhance diagnostic evaluation of PCD. PMID:19300264
77 FR 50696 - Proposed Data Collections Submitted for Public Comment and Recommendations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-22
... design with pre- and post-tests involving a total of six states: Three CRCCP grantee states (Alabama... may be used to fund the provision of screening and diagnostic tests. Additional program activities...
A framework provided an outline toward the proper evaluation of potential screening strategies.
Adriaensen, Wim J; Matheï, Cathy; Buntinx, Frank J; Arbyn, Marc
2013-06-01
Screening tests are often introduced into clinical practice without proper evaluation, despite the increasing awareness that screening is a double-edged sword that can lead to either net benefits or harms. Our objective was to develop a comprehensive framework for the evaluation of new screening strategies. Elaborating on the existing concepts proposed by experts, a stepwise framework is proposed to evaluate whether a potential screening test can be introduced as a screening strategy into clinical practice. The principle of screening strategy evaluation is illustrated for cervical cancer, which is a template for screening because of the existence of an easily detectable and treatable precursor lesion. The evaluation procedure consists of six consecutive steps. In steps 1-4, the technical accuracy, place of the test in the screening pathway, diagnostic accuracy, and longitudinal sensitivity and specificity of the screening test are assessed. In steps 5 and 6, the impact of the screening strategy on the patient and population levels, respectively, is evaluated. The framework incorporates a harm and benefit trade-off and cost-effectiveness analysis. Our framework provides an outline toward the proper evaluation of potential screening strategies before considering implementation. Copyright © 2013 Elsevier Inc. All rights reserved.
Mammography: an update of the EUSOBI recommendations on information for women.
Sardanelli, Francesco; Fallenberg, Eva M; Clauser, Paola; Trimboli, Rubina M; Camps-Herrero, Julia; Helbich, Thomas H; Forrai, Gabor
2017-02-01
This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a small number of women who undergo the test. Information is given on the recall during a screening programme and on the request for further work-up after a diagnostic mammography. The logic of the mammography report and of classification systems such as R1-R5 and BI-RADS is illustrated, and brief but clear information is given about the diagnostic performance of the test, with particular reference to interval cancers, i.e., those cancers that are missed at screening mammography. Moreover, the breast cancer risk due to radiation exposure from mammography is compared to the reduction in mortality obtained with the test, and the concept of overdiagnosis is presented with a reliable estimation of its extent. Information about new mammographic technologies (tomosynthesis and contrast-enhanced spectral mammography) is also given. Finally, frequently asked questions are answered. • Direct digital mammography should be preferred to film-screen or phosphor plates. • Screening (in asymptomatic women) should be distinguished from diagnosis (in symptomatic women). • A breast symptom has to be considered even after a negative mammogram. • Digital breast tomosynthesis increases cancer detection and decreases the recall rate. • Contrast-enhanced spectral mammography can help in cancer detection and lesion characterisation.
Leary, Alexandra F; Castro, David Gonzalez de; Nicholson, Andrew G; Ashley, Sue; Wotherspoon, Andrew; O'Brien, Mary E R; Popat, Sanjay
2012-01-01
EGFR screening requires good quality tissue, sensitivity and turn-around time (TAT). We report our experience of routine screening, describing sample type, TAT, specimen quality (cellularity and DNA yield), histopathological description, mutation result and clinical outcome. Non-small cell lung cancer (NSCLC) sections were screened for EGFR mutations (M+) in exons 18-21. Clinical, pathological and screening outcome data were collected for year 1 of testing. Screening outcome alone was collected for year 2. In year 1, 152 samples were tested, most (72%) were diagnostic. TAT was 4.9 days (95%confidence interval (CI)=4.5-5.5). EGFR-M+ prevalence was 11% and higher (20%) among never-smoking women with adenocarcinomas (ADCs), but 30% of mutations occurred in current/ex-smoking men. EGFR-M+ tumours were non-mucinous ADCs and 100% thyroid transcription factor (TTF1+). No mutations were detected in poorly differentiated NSCLC-not otherwise specified (NOS). There was a trend for improved overall survival (OS) among EGFR-M+ versus EGFR-M- patients (median OS=78 versus 17 months). In year 1, test failure rate was 19%, and associated with scant cellularity and low DNA concentrations. However 75% of samples with poor cellularity but representative of tumour were informative and mutation prevalence was 9%. In year 2, 755 samples were tested; mutation prevalence was 13% and test failure only 5.4%. Although samples with low DNA concentration (<2 ng/μL) had more test failures (30% versus 3.9% for [DNA]>2.2 ng/μL), the mutation rate was 9.2%. Routine epidermal growth factor receptor (EGFR) screening using diagnostic samples is fast and feasible even on samples with poor cellularity and DNA content. Mutations tend to occur in better-differentiated non-mucinous TTF1+ ADCs. Whether these histological criteria may be useful to select patients for EGFR testing merits further investigation. Copyright © 2011 Elsevier Ltd. All rights reserved.
Angheben, Andrea; Staffolani, Silvia; Anselmi, Mariella; Tais, Stefano; Degani, Monica; Gobbi, Federico; Buonfrate, Dora; Gobbo, Maria; Bisoffi, Zeno
2017-11-01
We analyzed the accuracy of Chagas Quick Test ® , a rapid diagnostic test, for the diagnosis of chronic Chagas disease through a retrospective study on a cohort of 669 patients consecutively examined at a single reference center in Italy, during a 7-year period. We observed high concordance with serological reference standard but low accuracy for screening purposes (sensitivity/specificity: 82.8%/98.7%) at least in our nonendemic context.
Requirements for Minimum Sample Size for Sensitivity and Specificity Analysis
Adnan, Tassha Hilda
2016-01-01
Sensitivity and specificity analysis is commonly used for screening and diagnostic tests. The main issue researchers face is to determine the sufficient sample sizes that are related with screening and diagnostic studies. Although the formula for sample size calculation is available but concerning majority of the researchers are not mathematicians or statisticians, hence, sample size calculation might not be easy for them. This review paper provides sample size tables with regards to sensitivity and specificity analysis. These tables were derived from formulation of sensitivity and specificity test using Power Analysis and Sample Size (PASS) software based on desired type I error, power and effect size. The approaches on how to use the tables were also discussed. PMID:27891446
[Express diagnostics of bovine leucosis by immune sensor based on surface plasmon resonance].
Pyrohova, L V; Starodub, M F; Artiukh, V P; Nahaieva, L I; Dobrosol, H I
2002-01-01
An immune sensor based on the surface plasmon resonance (SPR) was developed for express diagnostics of bovine leucosis. The sensor was used for detection of the level of antibodies against bovine leukaemia virus (BLV) in the blood serum. The industrially manufactured BLV antigen for screening test in the agar gel immunodiffusion (AGID) required the additional purification in order to be used in immune sensor analysis. It was shown that immune sensor analysis was more sensitive, rapid and simple in comparison with the traditional AGID test. It was stated that the developed immune sensor was capable to be used for performance of bovine leucosis screening at the farms and the minimal dilution of the serum should be 1:500.
Ahmed, Rukhsana; Levy, Elvira I; Maratina, Sylvia S; de Jong, Judith J; Asih, Puji B S; Rozi, Ismail E; Hawley, William; Syafruddin, Din; ter Kuile, Feiko
2015-10-29
Malaria in pregnancy poses a major public health problem in Indonesia with an estimated six million pregnancies at risk of Plasmodium falciparum or Plasmodium vivax malaria annually. In 2010, Indonesia introduced a screen and treat policy for the control of malaria in pregnancy at first antenatal visit using microscopy or rapid diagnostic tests (RDTs). A diagnostic study was conducted in Sumba, Indonesia to compare the performance of four different RDTs in predominately asymptomatic pregnant women under field condition. Women were screened for malaria at antenatal visits using field microscopy and four HRP-2/pLDH combination RDTs (Carestart™, First-Response(®), Parascreen(®) and SD-Bioline(®)). The test results were compared with expert microscopy and nested PCR. End user experience of the RDTs in the field was assessed by questionnaire. Overall 950 were recruited and 98.7 % were asymptomatic. The prevalence of malaria was 3.0-3.4 % by RDTs, and 3.6, 5.0 and 6.6 % by field microscopy, expert microscopy and PCR, respectively. The geometric-mean parasite density was low (P. falciparum = 418, P. vivax = 147 parasites/µL). Compared with PCR, the overall sensitivity of the RDTs and field microscopy to detect any species was 24.6-31.1 %; specificities were >98.4 %. Relative to PCR, First-Response(®) had the best diagnostic accuracy (any species): sensitivity = 31.1 %, specificity = 98.9 % and diagnostic odds ratio = 39.0 (DOR). The DOR values for Carestart™, Parascreen(®), SD-Bioline(®), and field microscopy were 23.4, 23.7, 23.5 and 29.2, respectively. The sensitivity of Pan-pLDH bands to detect PCR confirmed P. vivax mono-infection were 8.6-13.0 %. The sensitivity of the HRP-2 band alone to detect PCR confirmed P. falciparum was 10.3-17.9 %. Pan-pLDH detected P. falciparum cases undetected by the HRP-2 band resulting in a better test performance when both bands were combined. First Response(®) was preferred by end-users for the overall practicality. The diagnostic accuracy to detect malaria among mostly asymptomatic pregnant women and perceived ease of use was slightly better with First-Response(®), but overall, differences between the four RDTs were small and performance comparable to field microscopy. Combination RDTs are a suitable alternative to field microscopy to screen for malaria in pregnancy in rural Indonesia. The clinical relevance of low density malaria infections detected by PCR, but undetected by RDTs or microscopy needs to be determined.
Schwartz, S; Kohan, M; Pasion, R; Papenhausen, P R; Platt, L D
2018-02-01
Screening via noninvasive prenatal testing (NIPT) involving the analysis of cell-free DNA (cfDNA) from plasma has become readily available to screen for chromosomal and DNA aberrations through maternal blood. This report reviews a laboratory's experience with follow-up of positive NIPT screens for microdeletions. Patients that were screened positive by NIPT for a microdeletion involving 1p, 4p, 5p, 15q, or 22q who underwent diagnostic studies by either chorionic villus sampling or amniocentesis were evaluated. The overall positive predictive value for 349 patients was 9.2%. When a microdeletion was confirmed, 39.3% of the cases had additional abnormal microarray findings. Unrelated abnormal microarray findings were detected in 11.8% of the patients in whom the screen positive microdeletion was not confirmed. Stretches of homozygosity in the microdeletion were frequently associated with a false positive cfDNA microdeletion result. Overall, this report reveals that while cfDNA analysis will screen for microdeletions, the positive predictive value is low; in our series it is 9.2%. Therefore, the patient should be counseled accordingly. Confirmatory diagnostic microarray studies are imperative because of the high percentage of false positives and the frequent additional abnormalities not delineated by cfDNA analysis. © 2018 John Wiley & Sons, Ltd.
Malnutrition in hospitalized patients: results from La Rioja.
Martín Palmero, Ángela; Serrano Pérez, Andra; Chinchetru Ranedo, Mª José; Cámara Balda, Alejandro; Martínez de Salinas Santamarí, Mª Ángeles; Villar García, Gonzalo; Marín Lizárraga, Mª Del Mar
2017-03-30
There is a high malnutrition prevalence in hospitalized patients. To determine the malnutrition prevalence in hospitalized patients of La Rioja Community (Spain) when evaluated with different screening/ evaluation tools and its relationship with hospital stay and mortality. Cross sectional observational study of hospitalized adult patients (age > 18 years old) from medical and surgical departments that underwent within 72 h of their admission a nutritional screening with Malnutrition Universal Screening Tool (MUST), Nutritional Risk Screening (NRS) 2002, Controlling Nutritional Status (CONUT) y Subjective Global Assessment (SGA). 384 patients (273 medical and 111 surgical) were evaluated. Almost fifty percent of them were considered malnourished independently of the screening/assessment tool used. High concordance was found between SGA and NRS-2002 (k = 0.758). Malnourished patients had a longer hospital stay than those well-nourished (9.29 vs. 7.10 days; p = 0.002), used a greater number of medicines (9.2 vs. 7.4; p = 0.001) and underwent a higher number of diagnostic tests (16.4 vs. 12.5; p = 0,002). Half of the hospitalized patients in the medical and surgical department of La Rioja are malnourished. This is associated with a longer hospital stay, higher use of medicines, diagnostics tests and greater mortality. Malnutrition could be detected with easy screening tools to treat it appropriately.
Use of the Child Behavior Checklist as a Diagnostic Screening Tool in Community Mental Health
ERIC Educational Resources Information Center
Rishel, Carrie W.; Greeno, Catherine; Marcus, Steven C.; Shear, M. Katherine; Anderson, Carol
2005-01-01
Objective: This study examines whether the Child Behavior Checklist (CBCL) can be used as an accurate psychiatric screening tool for children in community mental health settings. Method: Associations, logistic regression models, and receiver operating characteristic (ROC) analysis were used to test the predictive relationship between the CBCL and…
ERIC Educational Resources Information Center
Van Norman, Ethan R.; Nelson, Peter M.; Klingbeil, David A.
2017-01-01
Educators need recommendations to improve screening practices without limiting students' instructional opportunities. Repurposing previous years' state test scores has shown promise in identifying at-risk students within multitiered systems of support. However, researchers have not directly compared the diagnostic accuracy of previous years' state…
Smith, David H; O'Keeffe Rosetti, Maureen; Mosen, David M; Rosales, A Gabriela; Keast, Erin; Perrin, Nancy; Feldstein, Adrianne C; Levin, Theodore R; Liles, Elizabeth G
2018-06-21
Colorectal cancer (CRC) causes more than 50,000 deaths each year in the United States but early detection through screening yields survival gains; those diagnosed with early stage disease have a 5-year survival greater than 90%, compared to 12% for those diagnosed with late stage disease. Using data from a large integrated health system, this study evaluates the cost-effectiveness of fecal immunochemical testing (FIT), a common CRC screening tool. A probabilistic decision-analytic model was used to examine the costs and outcomes of positive test results from a 1-FIT regimen compared with a 2-FIT regimen. The authors compared 5 diagnostic cutoffs of hemoglobin concentration for each test (for a total of 10 screening options). The principal outcome from the analysis was the cost per additional advanced neoplasia (AN) detected. The authors also estimated the number of cancers detected and life-years gained from detecting AN. The following costs were included: program management of the screening program, patient identification, FIT kits and their processing, and diagnostic colonoscopy following a positive FIT. Per-person costs ranged from $33 (1-FIT at 150ng/ml) to $92 (2-FIT at 50ng/ml) across screening options. Depending on willingness to pay, the 1-FIT 50 ng/ml and the 2-FIT 50 ng/ml are the dominant strategies with cost-effectiveness of $11,198 and $28,389, respectively, for an additional AN detected. The estimates of cancers avoided per 1000 screens ranged from 1.46 to 4.86, depending on the strategy and the assumptions of AN to cancer progression.
Greene, Greg; Sriruttan, Charlotte; Le, Thuy; Chiller, Tom; Govender, Nelesh P
2017-03-01
As HIV treatment programmes scale up to meet the UNAIDS 90-90-90 goals, care must be taken to start antiretroviral treatment safely in patients with advanced disease (CD4 counts <200 cells/μl) who are simultaneously at risk for opportunistic infections and immune reconstitution inflammatory syndrome. Invasive fungal diseases pose a great threat at this critical time point, though the development of inexpensive and highly accurate rapid diagnostic tests has changed the approach HIV programmes are taking to reduce the high mortality associated with these opportunistic infections. This article summarizes recent advances and findings in fungal opportunistic infection diagnostics with a focus on screening to prevent cryptococcal meningitis. Cryptococcal antigen (CrAg) screening using a lateral flow assay platform is cost-effective and feasible to implement as either a laboratory reflex or point-of-care test. Recent CrAg screening pilots have elucidated the varying prevalence of cryptococcal antigenemia across geographic regions, which may aid programme planning. Evidence from recently completed clinical trials provides a strong motivation for the use of CrAg titer to refine treatment options for patients with subclinical cryptococcal disease. Although several operational barriers to programme effectiveness still need to be addressed, the utility of CrAg screening using inexpensive and accurate antigen assays has been demonstrated in real-world HIV programmes, paving the way for development and testing of other fungal opportunistic infection screening strategies and for an integrated advanced HIV disease testing package to reduce AIDS mortality and ensure safe antiretroviral treatment initiation.
A Targeted Approach for Congenital Cytomegalovirus Screening Within Newborn Hearing Screening
McCollister, Faye P.; Sabo, Diane L.; Shoup, Angela G.; Owen, Kris E.; Woodruff, Julie L.; Cox, Edith; Mohamed, Lisa S.; Choo, Daniel I.; Boppana, Suresh B.
2017-01-01
BACKGROUND AND OBJECTIVE: Congenital cytomegalovirus (cCMV) infection remains a leading cause of childhood hearing loss. Currently universal CMV screening at birth does not exist in the United States. An alternative approach could be testing infants who do not pass their newborn hearing screening (NHS) for cCMV. This study was undertaken to evaluate whether a targeted approach will identify infants with CMV-related sensorineural hearing loss (SNHL). METHODS: Infants born at 7 US medical centers received NHS and were also screened for cCMV while in the newborn nursery. Infants who tested positive for CMV received further diagnostic audiologic evaluations to identify or confirm hearing loss. RESULTS: Between 2007 and 2012, 99 945 newborns were screened for both hearing impairment and cCMV. Overall, 7.0% of CMV-positive infants did not pass NHS compared with 0.9% of CMV-negative infants (P < .0001). Among the cCMV infants who failed NHS, diagnostic testing confirmed that 65% had SNHL. In addition, 3.6% of CMV-infected infants who passed their NHS had SNHL confirmed by further evaluation during early infancy. NHS in this cohort identified 57% of all CMV-related SNHL that occurred in the neonatal period. CONCLUSIONS: A targeted CMV approach that tests newborns who fail their NHS identified the majority of infants with CMV-related SNHL at birth. However, 43% of the infants with CMV-related SNHL in the neonatal period and cCMV infants who are at risk for late onset SNHL were not identified by NHS. PMID:28049114
List, Claudia; Qi, Weihong; Maag, Eva; Gottstein, Bruno; Müller, Norbert; Felger, Ingrid
2010-01-01
Background Production of native antigens for serodiagnosis of helminthic infections is laborious and hampered by batch-to-batch variation. For serodiagnosis of echinococcosis, especially cystic disease, most screening tests rely on crude or purified Echinococcus granulosus hydatid cyst fluid. To resolve limitations associated with native antigens in serological tests, the use of standardized and highly pure antigens produced by chemical synthesis offers considerable advantages, provided appropriate diagnostic sensitivity and specificity is achieved. Methodology/Principal Findings Making use of the growing collection of genomic and proteomic data, we applied a set of bioinformatic selection criteria to a collection of protein sequences including conceptually translated nucleotide sequence data of two related tapeworms, Echinococcus multilocularis and Echinococcus granulosus. Our approach targeted alpha-helical coiled-coils and intrinsically unstructured regions of parasite proteins potentially exposed to the host immune system. From 6 proteins of E. multilocularis and 5 proteins of E. granulosus, 45 peptides between 24 and 30 amino acids in length were designed. These peptides were chemically synthesized, spotted on microarrays and screened for reactivity with sera from infected humans. Peptides reacting above the cut-off were validated in enzyme-linked immunosorbent assays (ELISA). Peptides identified failed to differentiate between E. multilocularis and E. granulosus infection. The peptide performing best reached 57% sensitivity and 94% specificity. This candidate derived from Echinococcus multilocularis antigen B8/1 and showed strong reactivity to sera from patients infected either with E. multilocularis or E. granulosus. Conclusions/Significance This study provides proof of principle for the discovery of diagnostically relevant peptides by bioinformatic selection complemented with screening on a high-throughput microarray platform. Our data showed that a single peptide cannot provide sufficient diagnostic sensitivity whereas pooling several peptide antigens improved sensitivity; thus combinations of several peptides may lead the way to new diagnostic tests that replace, or at least complement conventional immunodiagnosis of echinococcosis. Our strategy could prove useful for diagnostic developments in other pathogens. PMID:20689813
Adler, Andreas; Geiger, Sebastian; Keil, Anne; Bias, Harald; Schatz, Philipp; deVos, Theo; Dhein, Jens; Zimmermann, Mathias; Tauber, Rudolf; Wiedenmann, Bertram
2014-10-17
Despite strong recommendations for colorectal cancer (CRC) screening, participation rates are low. Understanding factors that affect screening choices is essential to developing future screening strategies. Therefore, this study assessed patient willingness to use non-invasive stool or blood based screening tests after refusing colonoscopy. Participants were recruited during regular consultations. Demographic, health, psychological and socioeconomic factors were recorded. All subjects were advised to undergo screening by colonoscopy. Subjects who refused colonoscopy were offered a choice of non-invasive tests. Subjects who selected stool testing received a collection kit and instructions; subjects who selected plasma testing had a blood draw during the office visit. Stool samples were tested with the Hb/Hp Complex Elisa test, and blood samples were tested with the Epi proColon® 2.0 test. Patients who were positive for either were advised to have a diagnostic colonoscopy. 63 of 172 subjects were compliant to screening colonoscopy (37%). 106 of the 109 subjects who refused colonoscopy accepted an alternative non-invasive method (97%). 90 selected the Septin9 blood test (83%), 16 selected a stool test (15%) and 3 refused any test (3%). Reasons for blood test preference included convenience of an office draw, overall convenience and less time consuming procedure. 97% of subjects refusing colonoscopy accepted a non-invasive screening test of which 83% chose the Septin9 blood test. The observation that participation can be increased by offering non-invasive tests, and that a blood test is the preferred option should be validated in a prospective trial in the screening setting.
DEVELOPMENT OF A SCREENING PROTOCOL TO IDENTIFY INDIVIDUALS WITH DYSFUNCTIONAL BREATHING
Kiesel, Kyle; Rhodes, Tonya; Mueller, Jacob; Waninger, Alyssa; Butler, Robert
2017-01-01
Introduction Dysfunctional breathing (DB) has been linked to health conditions including low back pain and neck pain and adversely effects the musculoskeletal system. Individuals with DB often have decreased pain thresholds and impaired motor control, balance, and movement. No single test or screen identifies DB, which is multi-dimensional, and includes biochemical, biomechanical, and psychophysiological components. Several tools assess and test for DB, but no screen exists to determine whether additional testing and assessment are indicated. Purpose/Background The purpose of this study was to develop a breathing screening procedure that could be utilized by fitness and healthcare providers to screen for the presence of disordered breathing. A diagnostic test study approach was utilized to establish the diagnostic accuracy of the newly developed screen for DB. Methods A convenience sample of 51 subjects (27 females, 27.0 years, BMI 23.3) were included. To test for DB related to the biochemical dimension, end-tidal CO2 (ETCO2) was measured with a capnography unit. To test for DB related to biomechanical dimension, the Hi-Lo test was utilized. To test for DB related to the psychophysiological dimension, the Self Evaluation of Breathing Symptoms Questionnaire (SEBQ) and Nijmegen questionnaires were utilized. Potential screening items that have been shown to be related to DB in previous research and that could be performed by non-health care personnel were utilized to create the index test including activity level, breath hold time (BHT), respiration rate, and the Functional Movement Screen (FMS™). Results There were no strong correlations between the three measures of DB. Five subjects had normal breathing, 14 failed at least one measure, 20 failed at least two, and 12 failed all three. To develop screening items for each dimension, data were examined for association with failure. BHT and a four-item mini-questionnaire were identified as the most closely associated variables with failure of all three dimensions. A BHT of < 25 seconds and four questions were combined and yielded a sensitivity of 0.89 (0.85-0.93) and a specificity of 0.60 (0.18-0.92) for clinical identification of DB. Conclusion Easily obtained clinical measures of BHT and four questions can be utilized to screen for the presence of DB. If the screen is passed, there is an 89% chance that DB is not present. If the screen is failed, further assessment is recommended. Level of Evidence 2b PMID:29181255
La Cesa, S; Tamburin, S; Tugnoli, V; Sandrini, G; Paolucci, S; Lacerenza, M; Marchettini, P; Cruccu, G; Truini, A
2015-12-01
Patients with peripheral and central nervous system diseases may suffer from different types of pain, namely nociceptive, neuropathic and mixed pain. Although in some cases, the distinction between these types of pain is clinically evident, yet in some patients an accurate differential diagnosis requires dedicated clinical examination, screening questionnaires and diagnostic techniques some of which are available only in specialized pain centres. This review briefly addresses the currently agreed definitions of the different types of pain and shows how clinical examination, pain questionnaires and diagnostic tests can help the clinicians in identifying neuropathic pain.
de Jong, A S; Rahamat-Langendoen, J C; van Alphen, Ptw; Hilt, N; van Herk, Cmc; Pont, Sbeh; Melchers, Wjg; van de Bovenkamp, Jhb
2016-09-01
Mycoplasma genitalium and Trichomonas vaginalis are common sexually transmitted infections (STIs). In the Netherlands, testing for M. genitalium and T. vaginalis is not recommended for first-line STI screening. Recent reports about the increasing antimicrobial resistance in M. genitalium raise concern about the adequacy of current empirical treatment regimens. It is necessary to have insight in the prevalence of M. genitalium and T. vaginalis in order to evaluate current first-line STI screening and treatment protocols. During a five-month period, samples sent to two large medical microbiology diagnostic centres in the Netherlands for STI screening (Chlamydia trachomatis and Neisseria gonorrhoeae) were retrospectively tested for the prevalence of M. genitalium and T. vaginalis using the Diagenode S-DiaMGTV kit. A total of 1569 samples from 1188 unique patients (55.4% female) were tested. M. genitalium was the second most prevalent STI detected (4.5% of the patients), after C. trachomatis (8.3%). T. vaginalis was detected in 1.4% of the patients, comparable to the prevalence of N. gonorrhoeae (1.3%). Dual infections were only detected in a small number of patients (1.0%). Incorporation of M. genitalium into routine STI screening should be considered, because of its relatively high prevalence, the consequences of its detection for antibiotic treatment and because of the availability of easy-to-use molecular diagnostic tests. For T. vaginalis, routine screening may be considered, depending on local prevalence and (sub)population. © The Author(s) 2015.
Charman, Tony; Gotham, Katherine
2012-01-01
Background and Scope Significant progress has been made over the past two decades in the development of screening and diagnostic instruments for autism spectrum disorders (ASD). This article reviews this progress, including recent innovations, focussing on those instruments for which the strongest research data on validity exists, and then turns to addressing issues arising from their use in clinical settings. Findings Research studies have evaluated the ability of screens to prospectively identify cases of ASD in population-based and clinically-referred samples, as well as the accuracy of diagnostic instruments to map onto ‘gold standard’ clinical best estimate diagnosis. However, extension of the findings to clinical services must be done with caution, with a full understanding that instrument properties are sample-specific. Furthermore, we are limited by the lack of a true test for ASD, which remains a behaviourally-defined disorder. In addition screening and diagnostic instruments help clinicians least in the cases where they are most in want of direction, since their accuracy will always be lower for marginal cases. Conclusion Instruments help clinicians to collect detailed, structured information and increase accuracy and reliability of referral for in-depth assessment and recommendations for support, but further research is needed to refine their effective use in clinical settings. PMID:23539140
Song, Dongjian; Yue, Lifang; Zhan, Yuxiao; Zhang, Junjie; Yan, Zechen; Fan, Yingzhong; Yang, Heying; Zhang, Da; Liu, Qiuliang; Xia, Ziqiang; Qin, Pan; Jia, Jia; Yue, Ming; Yu, Jiekai; Zheng, Shu; Yang, Fuquan; Wang, Jiaxiang
2017-05-01
Breast cancer (BC) is the second-leading cause of cancer mortality after lung cancer in women owing partly to a lack of specific and sensitive tests for early screening and monitoring. The detection of novel specific BC serum indicators for screening purposes is an essential clinical need. A total of 437 serum specimens from 310 BC patients that were divided into mining and testing sets were collected in this study. In contrast with the conventional BC indicators through receiver operating characteristic, survival and hazard function curves, and multivariate Cox regression analyses, we intended to hunt for stable protein indicators from serum specimens and identify their diagnostic and prognostic potential for BC. We identified a unique serum peptide located at 6648 Da originated from apoC-III with a validated correlation with BC tumorigenesis with confirmation in a substantive testing set and minimization of systematic bias by pre-analytical parameters. We found that the diagnostic efficacy of this peptide is better than the present conventional BC diagnostic indicators either alone or in combination with conventional indicators in distinguishing BC patients from control volunteers. Moreover, this peptide denotes a stronger prognostic factor for BC patients than conventional indicators. In light of these findings, we speculate that this peptide is a potential diagnostic and prognostic indicator and a supplement to conventional indicators in monitoring BC. The detection of this peptide located at 6648 Da in sera could enhance early screening and assessment of the postoperative survival opportunity for BC patients.
Screening tests for aphasia in patients with stroke: a systematic review.
El Hachioui, Hanane; Visch-Brink, Evy G; de Lau, Lonneke M L; van de Sandt-Koenderman, Mieke W M E; Nouwens, Femke; Koudstaal, Peter J; Dippel, Diederik W J
2017-02-01
Aphasia has a large impact on the quality of life and adds significantly to the costs of stroke care. Early recognition of aphasia in stroke patients is important for prognostication and well-timed treatment planning. We aimed to identify available screening tests for differentiating between aphasic and non-aphasic stroke patients, and to evaluate test accuracy, reliability, and feasibility. We searched PubMed, EMbase, Web of Science, and PsycINFO for published studies on screening tests aimed at assessing aphasia in stroke patients. The reference lists of the selected articles were scanned, and several experts were contacted to detect additional references. Of each screening test, we estimated the sensitivity, specificity, likelihood ratio of a positive test, likelihood ratio of a negative test, and diagnostic odds ratio (DOR), and rated the degree of bias of the validation method. We included ten studies evaluating eight screening tests. There was a large variation across studies regarding sample size, patient characteristics, and reference tests used for validation. Many papers failed to report on the consecutiveness of patient inclusion, time between aphasia onset and administration of the screening test, and blinding. Of the three studies that were rated as having an intermediate or low risk of bias, the DOR was highest for the Language Screening Test and ScreeLing. Several screening tools for aphasia in stroke are available, but many tests have not been verified properly. Methodologically sound validation studies of aphasia screening tests are needed to determine their usefulness in clinical practice.
NASA Astrophysics Data System (ADS)
Wang, Wenbo; Feng, Shangyuan; Tai, Isabella T.; Chen, Guannan; Chen, Rong; Zeng, Haishan
2016-03-01
Colorectal cancer (CRC) is the third most common type of cancer and forth leading cause of cancer-related death. Early diagnosis is the key to long-term patient survival. Programmatic screening for the general population has shown to be cost-effective in reducing the incidence and mortality from CRC. Current CRC screening strategy relies on a broad range of test techniques such as fecal based tests and endoscopic exams. Occult blood tests like fecal immunochemical test is a cost effective way to detect CRC but have limited diagnostic values in detecting adenomatous polyp, the most treatable precursor to CRC. In the present work, we proposed the use of surface enhanced Raman spectroscopy (SERS) with silver nanoparticles as substrate to analyze blood plasma for detecting both CRC and adenomatous polyps. Blood plasma samples collected from healthy subjects and patients diagnosed with adenomas and CRC were prepared with nanoparticles and measured using a real-time fiber optic probe based Raman system. The collected SERS spectra are analyzed with partial least squares-discriminant analysis. Classification of normal versus CRC plus adenomatous polyps achieved diagnostic sensitivity of 86.4% and specificity of 80%. This exploratory study suggests that blood plasma SERS analysis has potential to become a screening test for detecting both CRC and adenomas.
2013-01-01
Background Colorectal cancer (CRC) is the most frequent cancer in Europe. Randomized clinical trials demonstrated that screening with fecal occult blood test (FOBT) reduces mortality from CRC. Accordingly, the European Community currently recommends population-based screening with FOBT. Other screening tests, such as computed tomography colonography (CTC) and optical colonoscopy (OC), are highly accurate for examining the entire colon for adenomas and CRC. Acceptability represents a critical determinant of the impact of a screening program. We designed a randomized controlled trial to compare participation rate and diagnostic yield of FOBT, CTC with computer-aided diagnosis, and OC as primary tests for population-based screening. Methods/Design A total of 14,000 subjects aged 55 to 64 years, living in the Florence district and never screened for CRC, will be randomized in three arms: group 1 (5,000 persons) invited to undergo CTC (divided into: subgroup 1A with reduced cathartic preparation and subgroup 1B with standard bowel preparation); group 2 (8,000 persons) invited to undergo a biannual FOBT for three rounds; and group 3 (1,000 persons) invited to undergo OC. Subjects of each group will be invited by mail to undergo the selected test. All subjects with a positive FOBT or CTC test (that is, mass or at least one polyp ≥6 mm) will be invited to undergo a second-level OC. Primary objectives of the study are to compare the participation rate to FOBT, CTC and OC; to compare the detection rate for cancer or advanced adenomas of CTC versus three rounds of biannual FOBT; to evaluate referral rate for OC induced by primary CTC versus three rounds of FOBT; and to estimate costs of the three screening strategies. A secondary objective of the study is to create a biological bank of blood and stool specimens from subjects undergoing CTC and OC. Discussion This study will provide information about participation/acceptability, diagnostic yield and costs of screening with CTC in comparison with the recommended test (FOBT) and OC. Trial registration ClinicalTrials.gov Identifier: NCT01651624. PMID:23497601
Becságh, Péter; Szakács, Orsolya
2014-10-01
During diagnostic workflow when detecting sequence alterations, sometimes it is important to design an algorithm that includes screening and direct tests in combination. Normally the use of direct test, which is mainly sequencing, is limited. There is an increased need for effective screening tests, with "closed tube" during the whole process and therefore decreasing the risk of PCR product contamination. The aim of this study was to design such a closed tube, detection probe based screening assay to detect different kind of sequence alterations in the exon 11 of the human c-kit gene region. Inside this region there are variable possible deletions and single nucleotide changes. During assay setup, more probe chemistry formats were screened and tested. After some optimization steps the taqman probe format was selected.
Technologic advances for evaluation of cervical cytology: is newer better?
Hartmann, K E; Nanda, K; Hall, S; Myers, E
2001-12-01
Among those women who have cervical cancer and have been screened, 14% to 33% of the cases represent failure to detect abnormalities that existed at the time of screening. New technologies intended to improve detection of cytologic abnormalities include liquid-based, thin-layer cytology (ThinPrep, AutoCyte), computerized rescreening (PAPNET), and algorithm-based computer rescreening (AutoPap). This report combines evidence reviews conducted for the U.S. Preventive Services Task Force and the Agency for Healthcare Research and Quality, in which we systematically identified articles on cervical neoplasia, cervical dysplasia, and screening published between January 1966 and March 2001. We note the challenges for improving screening methods, providing an overview of methods for collecting and evaluating cytologic samples, and examining the evidence about the diagnostic performance of new technologies for detecting cervical lesions. Using standard criteria for evaluation of the diagnostic tests, we determined that knowledge about the sensitivity, specificity, and predictive values of new technologies is meager. Only one study of liquid-based cytology used a reference standard of colposcopy, with histology as indicated, to assess participants with normal screening results. Lack of an adequate reference standard is the overwhelming reason that test characteristics cannot be properly assessed or compared. Most publications compare results of screening using the new technology with expert panel review of the cytologic specimen. In that case, the tests are not independent measures and do nothing to relate the screening test findings to the true status of the cervix, making determination of false-negatives, and thus sensitivity, specificity, and negative predictive value, impossible. We did not identify any literature about health outcomes or cost effectiveness of using these tools in a system of screening. For the purposes of guiding decision making about choice of screening tools, the current evidence is inadequate to gauge whether new technologies are "better" than conventional cytology..
Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J
2016-07-01
Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.
42 CFR 440.130 - Diagnostic, screening, preventive, and rehabilitative services.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 4 2011-10-01 2011-10-01 false Diagnostic, screening, preventive, and rehabilitative services. 440.130 Section 440.130 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... Definitions § 440.130 Diagnostic, screening, preventive, and rehabilitative services. (a) “Diagnostic services...
Lysosomal storage diseases: diagnostic confirmation and management of presymptomatic individuals.
Wang, Raymond Y; Bodamer, Olaf A; Watson, Michael S; Wilcox, William R
2011-05-01
To develop educational guidelines for the diagnostic confirmation and management of individuals identified by newborn screening, family-based testing after proband identification, or carrier testing in at-risk populations, and subsequent prenatal or postnatal testing of those who are presymptomatic for a lysosomal storage disease. Review of English language literature and discussions in a consensus development panel comprised an international group of experts in the clinical and laboratory diagnosis, treatment and management, newborn screening, and genetic aspects of lysosomal storage diseases. Although clinical trial and longitudinal data were used when available, the evidence in the literature is limited and consequently the recommendations must be considered as expert opinion. Guidelines were developed for Fabry, Gaucher, and Niemann-Pick A/B diseases, glycogen storage type II (Pompe disease), globoid cell leukodystrophy (Krabbe disease), metachromatic leukodystrophy, and mucopolysaccharidoses types I, II, and VI. These guidelines serve as an educational resource for confirmatory testing and subsequent clinical management of presymptomatic individuals suspected to have a lysosomal storage disease; they also help to define a research agenda for longitudinal studies such as the American College of Medical Genetics/National Institutes of Health Newborn Screening Translational Research Network.
Diagnostic characters within ITS2 DNA support molecular identification of Anastrepha suspensa
USDA-ARS?s Scientific Manuscript database
An approximately 220 bp fragment of the internal transcribed spacer 2 (ITS2) is screened as a diagnostic of Anastrepha suspensa and other pest fruit flies in the genus Anastrepha. The majority (96%) of the sites in this fragment are invariant among the test species but A. suspensa can be separated f...
ERIC Educational Resources Information Center
Sizoo, Bram B.; Horwitz, E. H.; Teunisse, J. P.; Kan, C. C.; Vissers, C. T. W. M.; Forceville, E. J. M.; Van Voorst, A. J. P.; Geurts, H. M.
2015-01-01
While various screening instruments for autism spectrum disorders are widely used in diagnostic assessments, their psychometric properties have not been simultaneously evaluated in the outpatient setting where these instruments are used most. In this study, we tested the Ritvo Autism Asperger Diagnostic Scale-Revised and two short versions of the…
Protein electrophoresis as a diagnostic and prognostic tool in raptor medicine.
Tatum, L M; Zaias, J; Mealey, B K; Cray, C; Bossart, G D
2000-12-01
Plasma proteins of 139 healthy adult birds of prey from 10 species were separated by electrophoresis to characterize and document normal reference ranges and species-specific electrophoretic patternsand to evaluate the value of this technique for health screening, disease diagnosis, and prognostic indication. Species studied included bald eagle (Haliaeetus leucocephalus), red-tailed hawk (Buteo jamaicensis), barn owl (Tyto alba), great horned owl (Bubo virginianus), turkey vulture (Cathartes aura), Harris' hawk (Parabuteo unicinctus), Stellar's sea eagle (Haliaeetus pelagicus), barred owl (Strix varia), screech owl (Otus asio), and black vulture (Coragyps atratus). Several clinical cases show the diagnostic/therapeutic value of protein electrophoresis in raptors. This study establishes species-specific reference ranges for several birds of prey and discusses the benefit of electrophoresis as a diagnostic technique in health screens, as a diagnostic aid in conjunction with other tests, and as a prognostic indicator in clinical evaluation of raptors.
Public stated preferences and predicted uptake for genome-based colorectal cancer screening
2014-01-01
Background Emerging developments in nanomedicine allow the development of genome-based technologies for non-invasive and individualised screening for diseases such as colorectal cancer. The main objective of this study was to measure user preferences for colorectal cancer screening using a nanopill. Methods A discrete choice experiment was used to estimate the preferences for five competing diagnostic techniques including the nanopill and iFOBT. Alternative screening scenarios were described using five attributes namely: preparation involved, sensitivity, specificity, complication rate and testing frequency. Fourteen random and two fixed choice tasks, each consisting of three alternatives, were offered to 2225 individuals. Data were analysed using the McFadden conditional logit model. Results Thirteen hundred and fifty-six respondents completed the questionnaire. The most important attributes (and preferred levels) were the screening technique (nanopill), sensitivity (100%) and preparation (no preparation). Stated screening uptake for the nanopill was 79%, compared to 76% for iFOBT. In the case of screening with the nanopill, the percentage of people preferring not to be screened would be reduced from 19.2% (iFOBT) to 16.7%. Conclusions Although the expected benefits of nanotechnology based colorectal cancer screening are improved screening uptake, assuming more accurate test results and less preparation involved, the relative preference of the nanopill is only slightly higher than the iFOBT. Estimating user preferences during the development of diagnostic technologies could be used to identify relative performance, including perceived benefits and harms compared to competitors allowing for significant changes to be made throughout the process of development. PMID:24642027
Ethical Implications: Screening for and Treatment of AIDS.
ERIC Educational Resources Information Center
Chng, Chwee Lye; Roddy, William Meyer
1987-01-01
This article discusses the ethical implications of using tests intended only to protect the blood supply as diagnostic or prognostic tests for Acquired Immune Deficiency Syndrome (AIDS). The reliability of these tests and the confidentiality of their results are discussed, along with ethical issues of research regarding AIDS. (MT)
Diagnostic accuracy of blood centers in the screening of blood donors for viral markers
Dogbe, Elliot Eli; Arthur, Fareed
2015-01-01
Introduction Blood transfusion still remains a life saving intervention in almost all healthcare facilities worldwide. Screening of blood donors/blood units is done in almost every blood bank facility before the blood units/blood components are transfused to prevent transfusion-transmissible infections. The kind of testing kits or the methods used by a facility and the technical expertise of the personnel greatly affects the screening results of a facility. This study was aimed at evaluating the diagnostic accuracy of five hospital-based blood bank testing facilities (Komfo Anokye Teaching Hospital KNUST, Kwame Nkrumah University of Science and Technology, Agogo, Bekwai and Sunyani) that used rapid immunochromatograhic assays (RIA) in screening blood donors/blood units in Ghana. Methods Blood samples (300) from the five testing facilities and their screening results for hepatitis B surface antigen (HBsAg), antibodies to hepatitis C virus (HCV) and human immunodeficiency virus (HIV) using RIAs were obtained. All the samples were then analysed for the three viral markers using 3rd generational enzyme linked immunosorbent assay (ELISA) kit as the gold standard. Results The mean false positive for HBsAg was 2.2% with Bekwai testing facility having the highest of 4.4%. For HCV, the mean false positive was 2.8% with Agogo and Bekwai testing facilities having the highest of 8.7% respectively. For HIV screening, the mean false positive was 11.1% with Bekwai testing facility having the highest of 28.0%. The mean false negative for the facilities were 3.0% for HBV, 75.0% for HCV and 0.0% for HIV with KATH having the highest of 6.3% for HBV, Bekwai having the highest of 100% for HCV and no facility showing false negative for HIV. Mean sensitivity of the screening procedure for the facilities was 97.0%, 25.0% and 100.0% whilst the mean specificity was 97.8%, 97.2% and 88.9% for HBV, HCV and HIV respectively. Statistical comparison among the testing facilities showed no significant differences among the various testing centres for HBV screening; however, significant differences were obtained for HCV and HIV screening. Conclusion This study has shown that there is no standardised screening procedure for blood bank testing facilities in the country. There is therefore an urgent need for an internal and external control body to oversee screening procedures in blood banks across the country. PMID:26090067
Eliminating cost-sharing requirements for colon cancer screening in Medicare.
Howard, David H; Guy, Gery P; Ekwueme, Donatus U
2014-12-15
Medicare beneficiaries do not have to pay for screening colonoscopies but must pay coinsurance if a polyp is removed via polypectomy. Likewise, beneficiaries do not have to pay for fecal occult blood tests but are liable for cost-sharing for diagnostic colonoscopies after a positive test. Legislative and regulatory requirements related to colorectal cancer screening are described, and on the basis of Medicare claims, it is estimated that Medicare spending would increase by $48 million annually if Medicare were to waive cost-sharing requirements for these services. The economic impact on Medicare if beneficiaries were not responsible for any cost-sharing requirements related to colorectal cancer screening services is described. © 2014 American Cancer Society.
Roalf, David R; Moore, Tyler M; Wolk, David A; Arnold, Steven E; Mechanic-Hamilton, Dawn; Rick, Jacqueline; Kabadi, Sushila; Ruparel, Kosha; Chen-Plotkin, Alice S; Chahine, Lama M; Dahodwala, Nabila A; Duda, John E; Weintraub, Daniel A; Moberg, Paul J
2016-01-01
Introduction Screening for cognitive deficits is essential in neurodegenerative disease. Screening tests, such as the Montreal Cognitive Assessment (MoCA), are easily administered, correlate with neuropsychological performance and demonstrate diagnostic utility. Yet, administration time is too long for many clinical settings. Methods Item response theory and computerised adaptive testing simulation were employed to establish an abbreviated MoCA in 1850 well-characterised community-dwelling individuals with and without neurodegenerative disease. Results 8 MoCA items with high item discrimination and appropriate difficulty were identified for use in a short form (s-MoCA). The s-MoCA was highly correlated with the original MoCA, showed robust diagnostic classification and cross-validation procedures substantiated these items. Discussion Early detection of cognitive impairment is an important clinical and public health concern, but administration of screening measures is limited by time constraints in demanding clinical settings. Here, we provide as-MoCA that is valid across neurological disorders and can be administered in approximately 5 min. PMID:27071646
Incorporating DNA Sequencing into Current Prenatal Screening Practice for Down's Syndrome
Wald, Nicholas J.; Bestwick, Jonathan P.
2013-01-01
Background Prenatal screening for Down's syndrome is performed using biochemical and ultrasound markers measured in early pregnancy such as the Integrated test using first and second trimester markers. Recently, DNA sequencing methods have been introduced on free DNA in maternal plasma, yielding a high screening performance. These methods are expensive and there is a test failure rate. We determined the screening performance of merging the Integrated test with the newer DNA techniques in a protocol that substantially reduces the cost compared with universal DNA testing and still achieves high screening performance with no test failures. Methods Published data were used to model screening performance of a protocol in which all women receive the first stage of the Integrated test at about 11 weeks of pregnancy. On the basis of this higher risk women have reflex DNA testing and lower risk women as well as those with a failed DNA test complete the Integrated test at about 15 weeks. Results The overall detection rate was 95% with a 0.1% false-positive rate if 20% of women were selected to receive DNA testing. If all women had DNA testing the detection rate would be 3 to 4 percentage points higher with a false-positive rate 30 times greater if women with failed tests were treated as positive and offered a diagnostic amniocentesis, or 3 times greater if they had a second trimester screening test (Quadruple test) and treated as positive only if this were positive. The cost per women screened would be about one-fifth, compared with universal DNA testing, if the DNA test were 20 times the cost of the Integrated test. Conclusion The proposed screening protocol achieves a high screening performance without programme test failures and at a substantially lower cost than offering all women DNA testing. PMID:23527014
NASA Astrophysics Data System (ADS)
Philipsen, R. H. H. M.; Sánchez, C. I.; Maduskar, P.; Melendez, J.; Peters-Bax, L.; Peter, J. G.; Dawson, R.; Theron, G.; Dheda, K.; van Ginneken, B.
2015-07-01
Molecular tests hold great potential for tuberculosis (TB) diagnosis, but are costly, time consuming, and HIV-infected patients are often sputum scarce. Therefore, alternative approaches are needed. We evaluated automated digital chest radiography (ACR) as a rapid and cheap pre-screen test prior to Xpert MTB/RIF (Xpert). 388 suspected TB subjects underwent chest radiography, Xpert and sputum culture testing. Radiographs were analysed by computer software (CAD4TB) and specialist readers, and abnormality scores were allocated. A triage algorithm was simulated in which subjects with a score above a threshold underwent Xpert. We computed sensitivity, specificity, cost per screened subject (CSS), cost per notified TB case (CNTBC) and throughput for different diagnostic thresholds. 18.3% of subjects had culture positive TB. For Xpert alone, sensitivity was 78.9%, specificity 98.1%, CSS $13.09 and CNTBC $90.70. In a pre-screening setting where 40% of subjects would undergo Xpert, CSS decreased to $6.72 and CNTBC to $54.34, with eight TB cases missed and throughput increased from 45 to 113 patients/day. Specialists, on average, read 57% of radiographs as abnormal, reducing CSS ($8.95) and CNTBC ($64.84). ACR pre-screening could substantially reduce costs, and increase daily throughput with few TB cases missed. These data inform public health policy in resource-constrained settings.
ERIC Educational Resources Information Center
Foorman, Barbara R.; Kershaw, Sarah; Petscher, Yaacov
2013-01-01
Florida requires that students who do not meet grade-level reading proficiency standards on the end-of-year state assessment (Florida Comprehensive Assessment Test, FCAT) receive intensive reading intervention. With the stakes so high, teachers and principals are interested in using screening or diagnostic assessments to identify students with a…
Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen
2006-01-01
OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726
Screening and syndromic approaches to identify gonorrhea and chlamydial infection among women.
Sloan, N L; Winikoff, B; Haberland, N; Coggins, C; Elias, C
2000-03-01
The standard diagnostic tools to identify sexually transmitted infections are often expensive and have laboratory and infrastructure requirements that make them unavailable to family planning and primary health-care clinics in developing countries. Therefore, inexpensive, accessible tools that rely on symptoms, signs, and/or risk factors have been developed to identify and treat reproductive tract infections without the need for laboratory diagnostics. Studies were reviewed that used standard diagnostic tests to identify gonorrhea and cervical chlamydial infection among women and that provided adequate information about the usefulness of the tools for screening. Aggregation of the studies' results suggest that risk factors, algorithms, and risk scoring for syndromic management are poor indicators of gonorrhea and chlamydial infection in samples of both low and high prevalence and, consequently, are not effective mechanisms with which to identify or manage these conditions. The development and evaluation of other approaches to identify gonorrhea and chlamydial infections, including inexpensive and simple laboratory screening tools, periodic universal treatment, and other alternatives must be given priority.
Potential biases in colorectal cancer screening using faecal occult blood test.
Riboe, Dea Grip; Dogan, Tilde Steen; Brodersen, John
2013-04-01
Colorectal cancer (CRC) is one of the most common types of cancer in European countries and associated with a high mortality rate. A 16% relative risk reduction (RRR) of mortality was found in a meta-analysis based on four randomized controlled trials (RCT) on CRC screening. The aim of this paper was to scrutinize these trials for potential biases and assess their influence on the screening trials. The four RCTs were reviewed based on the principles of 'Critical Appraisal of the Medical Literature'. Principal investigators of the four RCTs were contacted to clarify uncertainties in their study. Data were collected from The Danish Data Archives. Authors of the Cochrane review were contacted. Six biases were identified, of which five favour screening. Three of the biases identified were specific to CRC screening: type of diagnostic method, place of surgery and diagnostic delay. The 16% RRR in CRC mortality found in the updated Cochrane review's meta-analysis is overestimated. © 2012 Blackwell Publishing Ltd.
Saliva as a non-invasive diagnostic tool for inflammation and insulin-resistance
Desai, Gauri S; Mathews, Suresh T
2014-01-01
Saliva has been progressively studied as a non-invasive and relatively stress-free diagnostic alternative to blood. Currently, saliva testing is used for clinical assessment of hormonal perturbations, detection of HIV antibodies, DNA analysis, alcohol screening, and drug testing. Recently, there has been increasing interest in evaluating the diagnostic potential of saliva in obesity, inflammation, and insulin-resistance. Current literature has demonstrated elevated levels of inflammatory biomarkers including C-reactive protein, tumor necrosis factor-α, interleukin-6, and interferon-γ in saliva of obese/overweight children and adults. Salivary antioxidant status has also been studied as a measure of oxidative stress in individuals with type 2 diabetes. Further, several studies have demonstrated correlations of salivary markers of stress and insulin resistance including cortisol, insulin, adiponectin, and resistin with serum concentrations. These findings suggest the potential diagnostic value of saliva in health screening and risk stratification studies, particularly in the pediatric population, with implications for inflammatory, metabolic and cardiovascular conditions. However, additional studies are required to standardize saliva collection and storage procedures, validate analytical techniques for biomarker detection, and establish reference ranges for routine clinical use. The purpose of this review is to summarize and evaluate recent advancements in using saliva as a diagnostic tool for inflammation and insulin-resistance. PMID:25512775
Diagnostic Yield of 2 Strategies for Adult Celiac Disease Identification in Primary Care.
Scoglio, Riccardo; Trifirò, Gianluca; Sandullo, Antonino; Marangio, Giovanni; D'Agate, Cinzia; Costa, Stefano; Pellegrino, Salvatore; Alibrandi, Angela; Aiello, Andrea; Currò, Giovanni; Cuzzupè, Chiara; Comisi, Fabrizio; Amato, Salvatore; Conti Nibali, Roberto; Oteri, Sergio; Magazzu, Giuseppe; Carroccio, Antonio
2017-12-18
To compare the diagnostic yield and cost-consequences of 2 strategies, screening regardless of symptoms versus case finding (CF), using a point-of-care test (POCT), for the detection of celiac disease (CD) in primary care, to bridge the diagnostic gap of CD in adults. All subjects under 75 years of age who consecutively went to their general practitioners' offices were offered POCT for anti-transglutaminase immunoglobulin A antibodies. The POCT was performed on all subjects who agreed, and then a systematic search for symptoms or conditions associated with higher risk for CD was performed, immediately after the test but before knowing the test results. The 2 resulting groups were: (a) POCT positive and (b) symptomatic subject at CF. Subjects were defined as symptomatic at CF in the presence of 1 or more symptoms. All POCT-positive or symptomatic subjects at CF were referred to the CD Centers for confirmation of CD. Data on resource consumption were gathered from patients' charts. Cost of examinations, and diagnostic and laboratory tests were estimated with regional outpatient tariffs (Sicily), and a price of &OV0556;2.5 was used for each POCT. Of a total of 2197 subjects who agreed to participate in the study, 36 (1.6%) and 671 (30.5%) were POCT positive and symptomatic at CF, respectively. The yield from the screening and CF was 5 new celiac patients. The total cost and mean cost for each new CD case were &OV0556;7497.35 and &OV0556;1499.47 for the POCT screening strategy, and &OV0556;9855.14 and &OV0556;1971.03 for the CF strategy, respectively. Assuming consecutive use of both strategies, performing POCT only in symptomatic subjects at CF, the calculated yield would be 4 new diagnoses with a total cost of &OV0556;2345.84 and a mean cost of &OV0556;586.46 for each newly diagnosed patient. Only 1 patient was celiac despite a negative POCT. Testing symptomatic subjects at CF only by POCT seems the most cost-effective strategy to bridge the diagnostic gap of adult CD in primary care.
Woś, Halina; Sankiewicz-Szkółka, Magda; Więcek, Sabina; Kordys-Darmolińska, Bożena; Grzybowska-Chlebowczyk, Urszula; Kniażewska, Maria
2015-01-01
Neonatal cystic fibrosis screening contributes to an early diagnosis of cystic fibrosis and to implementing appropriate therapeutic management. Long-standing screening tests have made it possible to identify a group of newborns in whom the diagnosis was ambiguous and required further specialised tests. The aim is to present cases of patients with a positive result of newborn screening for cystic fibrosis who were found to be carriers of the mutation in both alleles, however the lack of clinical symptoms and correct sweat testing values did not lead doctors to diagnosing cystic fibrosis and by the same token implementing the treatment. The analysis encompassed a group of 22 infants and children 3 months to 3 years of age, in whom, in spite of a positive result of newborn screening for cystic fibrosis and the presence of 2 mutations in the CFTR gene, the diagnosis of cystic fibrosis was not made, and appropriate treatment was not administered because of diagnostic doubts (due to correct concentration of chlorides in sweat, correct IRT level and lack of clinical signs of cystic fibrosis). The control group consisted of 55 children treated in our centre, in whom neonatal screening for cystic fibrosis was positive and the diagnosis was confirmed by genetic testing, sweat chloride testing and IRT concentration. There were no differences in birth body weight between the groups. The differences in chlorideion levels in sweat secretion tests and mean IRT values were statistically significant and were: 97.5 for the control group and 26.4 for the test group. At the present time there are no clinical symptoms to give a diagnosis of cystic fibrosis and start treatment in the test group. Newborn screening contributes not only to an early diagnosis of cystic fibrosis but also to CFTR-related metabolic syndromes (CRMS), which is a phenomenon requiring further observation. This fact constitutes a definite psychological problem for the parents of these patients. .
Malaria Diagnostics in Clinical Trials
Murphy, Sean C.; Shott, Joseph P.; Parikh, Sunil; Etter, Paige; Prescott, William R.; Stewart, V. Ann
2013-01-01
Malaria diagnostics are widely used in epidemiologic studies to investigate natural history of disease and in drug and vaccine clinical trials to exclude participants or evaluate efficacy. The Malaria Laboratory Network (MLN), managed by the Office of HIV/AIDS Network Coordination, is an international working group with mutual interests in malaria disease and diagnosis and in human immunodeficiency virus/acquired immunodeficiency syndrome clinical trials. The MLN considered and studied the wide array of available malaria diagnostic tests for their suitability for screening trial participants and/or obtaining study endpoints for malaria clinical trials, including studies of HIV/malaria co-infection and other malaria natural history studies. The MLN provides recommendations on microscopy, rapid diagnostic tests, serologic tests, and molecular assays to guide selection of the most appropriate test(s) for specific research objectives. In addition, this report provides recommendations regarding quality management to ensure reproducibility across sites in clinical trials. Performance evaluation, quality control, and external quality assessment are critical processes that must be implemented in all clinical trials using malaria tests. PMID:24062484
Kong, Ling-Ying; Du, Wei; Wang, Li; Yang, Zhi; Zhang, Hong-Sheng
2015-01-01
DNA methylation has been proposed as a potential biomarker for cervical cancer detection. This study aimed to evaluate the diagnostic role of paired boxed gene 1 (PAX1) methylation for cervical cancer screening in Asians. Eligible studies were retrieved by searching the electronic databases, and the quality of the enrolled studies was assessed via the quality assessment for studies of diagnostic accuracy (QUADAS) tool. The bivariate meta-analysis model was employed to generate the summary receiver operator characteristic (SROC) curve using Stata 12.0 software. Cochran's Q test and I2 statistics were applied to assess heterogeneity among studies. Publication bias was evaluated by the Deeks' funnel plot asymmetry test. A total of 9 articles containing 15 individual studies were included. The SROC analysis showed that single PAX1 methylation allowed for the discrimination between cancer/high-grade squamous intraepithelial lesion (HSIL) patients and normal individuals with a sensitivity (95% confidence interval) of 0.80 (0.70 - 0.87) and specificity of 0.89 (0.86 - 0.92), corresponding to an area under curve (AUC) of 0.92. Notably, our subgroup analysis suggested that combing parallel testing of PAX1 methylation and HPV DNA (AUC, sensitivity, and specificity of 0.90, 0.82, and 0.84, respectively) seemed to harbor higher accuracy than single HPV DNA testing (AUC, sensitivity, and specificity of 0.81, 0.86, and 0.67, respectively). PAX1 methylation hallmarks a potential diagnostic value for cervical cancer screening in Asians, and parallel testing of PAX1 methylation and HPV in cervical scrapings confers an improved accuracy than single HPV DNA testing.
Lou, Stina; Nielsen, Camilla P; Hvidman, Lone; Petersen, Olav B; Risør, Mette B
2016-10-21
It is well documented that pregnant women experience increased worry and uncertainty following a high-risk prenatal screening result. While waiting for diagnostic results this worry continues to linger. It has been suggested that high-risk women put the pregnancy mentally 'on hold' during this period, however, not enough is known about how high-risk women and their partners cope while waiting for diagnostic results. The aim of this study was to identify the strategies employed to cope with worry and uncertainty. Qualitative, semi-structured interviews with 16 high-risk couples who underwent diagnostic testing. The couples were recruited at a university hospital fetal medicine unit in Denmark. Data were analysed using thematic analysis. All couples reported feeling worried and sad upon receiving a high-risk screening result. While waiting for diagnostic results, the couples focused on coming to their own understanding of the situation and employed both social withdrawal and social engagement as strategies to prevent worry from escalating. Additionally, couples used gratitude, reassuring reasoning and selective memory as means to maintain hopes for a good outcome. Discussions about what to do in case of an abnormal test result were notably absent in the accounts of waiting. This bracketing of the potential abnormal result allowed the couples to hold on to a 'normal' pregnancy and to employ an 'innocent-till-proven-guilty' approach to their worries about the fetus's health. None of the interviewed couples regretted having prenatal screening and all of them expected to have prenatal screening in a future pregnancy. The couples in this study did not put the pregnancy mentally 'on hold'. Worry and uncertainty must be understood as managed through a diverse range of practical and emotional strategies that change and overlap in the process of waiting. Clinicians may support appropriate ways of coping with worry and waiting through empathetic and empowering clinical communication. In addition to providing adequate information and presenting options available, clinicians may support high-risk women/couples by encouraging them to seek their own personal understandings and management strategies as a way to gain some control in an uncertain situation.
Quirino, Isabel G; Silva, Jose Maria P; Diniz, Jose S; Lima, Eleonora M; Rocha, Ana Cristina S; Simões e Silva, Ana Cristina; Oliveira, Eduardo A
2011-01-01
The aim of this study was to evaluate the diagnostic accuracy of dimercapto-succinic acid renal scintigraphy and renal ultrasound in identifying high grade vesicoureteral reflux in children after a first episode of urinary tract infection. A total of 533 children following a first urinary tract infection were included in the analysis. Patients were assessed by 3 diagnostic imaging studies, renal ultrasound, dimercapto-succinic acid scan and voiding cystourethrography. The main event of interest was the presence of high grade (III to V) vesicoureteral reflux. The combined and separate diagnostic accuracy of screening methods was assessed by calculation of diagnostic OR, sensitivity, specificity, positive predictive value, negative predictive value and likelihood ratio. A total of 246 patients had reflux, of whom 144 (27%) had high grade (III to V) disease. Sensitivity, negative predictive value and diagnostic OR of ultrasound for high grade reflux were 83.3%, 90.8% and 7.9, respectively. Dimercapto-succinic acid scan had the same sensitivity as ultrasound but a higher negative predictive value (91.7%) and diagnostic OR (10.9). If both tests were analyzed in parallel by using the OR rule, ie a negative diagnosis was established only when both test results were normal, sensitivity increased to 97%, negative predictive value to 97% and diagnostic OR to 25.3. Only 9 children (6.3%) with dilating reflux had an absence of alterations in both tests. Our findings support the idea that ultrasound and dimercapto-succinic acid scan used in combination are reliable predictors of dilating vesicoureteral reflux. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Miglioretti, Diana L.; Rutter, Carolyn M.; Bradford, Susan Carol; Zauber, Ann G.; Kessler, Larry G.; Feuer, Eric J.; Grossman, David C.
2014-01-01
Background Screening for fecal occult blood can be effective in reducing colorectal cancer mortality only if positive tests are appropriately followed up with complete diagnostic evaluation (i.e., colonoscopy or flexible sigmoidoscopy with double contrast barium enema) and treatment. Objectives To examine whether rates of complete diagnostic evaluation following a positive fecal occult blood test (FOBT) have improved over time after the implementation of tracking systems and physician guidelines within a large integrated health care organization. Research Design From 1993 to 2005, 8513 positive FOBTs were identified on 8291 enrollees aged 50–79 of a large health care system. Automated records were used to identify repeat FOBTs, colonoscopy, flexible sigmoidoscopy, and double-contrast barium enema within one year after the positive FOBT. National rates of complete diagnostic evaluation were estimated from the 2005 National Health Interview Survey. Results In this integrated health care organization, the percentage of positive FOBTs followed by complete diagnostic evaluation within one year increased from 57%–64% in 1993–1996 to 82%–86% from 2000–2005. Use of repeat FOBT following a positive FOBT decreased from 28–31% in 1993–1996 to 6–11% in 2000–2005. Based on the National Health Interview Survey, only 52% of positive FOBTs from 2000–2005 were followed by complete diagnostic evaluation nationally. Conclusions Adherence to recommendations for complete diagnostic evaluation following a positive FOBT has greatly improved over time in an integrated group medical practice. Through the use of tracking systems and screening guidelines, it may be possible to reach levels of follow-up that are comparable to those observed in randomized trials. PMID:18725839
Todd, Catherine S; Mansoor, Ghulam Farooq; Buhler, Cyril; Rahimi, Habiburrahman; Zekria, Rohullah; Fernandez, Stefan; Mikhail, Amy F W; Scott, Paul T; Yingst, Samuel L
2016-08-01
To measure prevalence of prior/current Plasmodium vivax and Plasmodium falciparum (PV and PF), Brucella spp. (BR), dengue virus (DENV), Leishmania donovani (visceral leishmaniasis; VL), and Crimean-Congo hemorrhagic fever (CCHF) virus exposure among Afghan National Army (ANA) recruits. Randomly chosen, nationally representative serum samples from consenting men aged 18-40 years and who were screened between February 2010 and January 2011 were tested, with ∼25 samples/province. Samples were screened for PV and PF antigens and VL antibody with rapid diagnostic tests. Reactive malaria screening results were confirmed with polymerase chain reaction assay. Enzyme-linked immunosorbent assays were used to screen for CCHF and DENV antibodies; reactive DENV samples were confirmed with the plaque-reduction neutralization test. BR screening and confirmatory testing was performed with slide and tube agglutination, respectively. Correlates of BR titres >1:80 were analyzed using logistic regression. Of 809 participants contributing specimens, 62% had previously lived outside Afghanistan, predominantly in Pakistan and Iran. CCHF (4.1%, n = 33), DENV (2.1%, n = 17), and VL (1.0%, n = 8) antibody prevalence was low. For PV and PF, only 7 out of 56 reactive samples had detectable nucleic acid. For BR, 8.0% (n = 65) of samples had screening titers >1:40, of which 83.1% had confirmatory titers >1:80. Participants from Kabul and surrounding provinces had lower odds (OR = 0.19, 95% CI: 0.04-1.00) of BR antibody compared with other regions. BR exposure was relatively common with a nearly national distribution, whereas geographic distribution for other pathogens aligned roughly with the expected vector distribution. Public health protection measures should include vector control, food safety, and enhanced diagnostics for acute febrile illness.
"Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.
Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H
2016-01-01
To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.
[Models of the organization of neonatal screening].
Cassio, A; Piazzi, S; Colli, C; Balsamo, A; Bozza, D; Salardi, S; Sprovieri, G; Cacciari, E
1994-01-01
The authors evaluate the different organizational strategies of a congenital hypothyroidism screening program. Positive and negative aspects of laboratory screening tests (TSH only, T4-supplemental TSH, TSH and T4), organization strategies (centralization or decentralization), recall and first follow-up criteria are examined. The authors consider that the necessity for an early diagnostic confirmation can be associated with a precise etiologic diagnosis and an evaluation of the prenatal severity of congenital hypothyroidism factors. Some European and North-American experiences are compared with the activity of a regional Italian screening center.
Early Detection of Lung Cancer Using Nano-Nose - A Review
Fernandes, M. P.; Venkatesh, S; Sudarshan, B. G
2015-01-01
Lung cancer is one of the malignancies causing deaths worldwide. The yet to be developed non-invasive diagnostic techniques, are a challenge for early detection of cancer before it progresses to its later stages. The currently available diagnostic methods are expensive or invasive, and are not fit for general screening purposes. Early identification not only helps in detecting primary cancer, but also in treating its secondaries; which creates a need for easily applicable tests to screen individuals at risk. A detailed review of the various screening methods, including the latest trend of breath analysis using gold nanoparticles, to identify cancer at its early stage, are studied here. The VOC based breath biomarkers are used to analyze the exhaled breath of the patients. These biomarkers are utilized by Chemiresistors coated with gold nanoparticles, which are found to be the most suited technique for early detection of lung cancer. This technique is highly accurate and is relatively easy to operate and was tested on smokers and non-smokers. This review also gives as an outline of the fabrication and working of the device Na-Nose. The Chemiresistors coated with Gold nanoparticles, show a great potential in being an non-invasive and cost-effective diagnostic technique for early detection of lung cancer. PMID:26628933
Early Detection of Lung Cancer Using Nano-Nose - A Review.
Fernandes, M P; Venkatesh, S; Sudarshan, B G
2015-01-01
Lung cancer is one of the malignancies causing deaths worldwide. The yet to be developed non-invasive diagnostic techniques, are a challenge for early detection of cancer before it progresses to its later stages. The currently available diagnostic methods are expensive or invasive, and are not fit for general screening purposes. Early identification not only helps in detecting primary cancer, but also in treating its secondaries; which creates a need for easily applicable tests to screen individuals at risk. A detailed review of the various screening methods, including the latest trend of breath analysis using gold nanoparticles, to identify cancer at its early stage, are studied here. The VOC based breath biomarkers are used to analyze the exhaled breath of the patients. These biomarkers are utilized by Chemiresistors coated with gold nanoparticles, which are found to be the most suited technique for early detection of lung cancer. This technique is highly accurate and is relatively easy to operate and was tested on smokers and non-smokers. This review also gives as an outline of the fabrication and working of the device Na-Nose. The Chemiresistors coated with Gold nanoparticles, show a great potential in being an non-invasive and cost-effective diagnostic technique for early detection of lung cancer.
Langlois, Sylvie; Johnson, JoAnn; Audibert, François; Gekas, Jean; Forest, Jean-Claude; Caron, André; Harrington, Keli; Pastuck, Melanie; Meddour, Hasna; Tétu, Amélie; Little, Julian; Rousseau, François
2017-12-01
This study evaluates the impact of offering cell-free DNA (cfDNA) screening as a first-tier test for trisomies 21 and 18. This is a prospective study of pregnant women undergoing conventional prenatal screening who were offered cfDNA screening in the first trimester with clinical outcomes obtained on all pregnancies. A total of 1198 pregnant women were recruited. The detection rate of trisomy 21 with standard screening was 83% with a false positive rate (FPR) of 5.5% compared with 100% detection and 0% FPR for cfDNA screening. The FPR of cfDNA screening for trisomies 18 and 13 was 0.09% for each. Two percent of women underwent an invasive diagnostic procedure based on screening or ultrasound findings; without the cfDNA screening, it could have been as high as 6.8%. Amongst the 640 women with negative cfDNA results and a nuchal translucency (NT) ultrasound, only 3 had an NT greater or equal to 3.5 mm: one had a normal outcome and two lost their pregnancy before 20 weeks. cfDNA screening has the potential to be a highly effective first-tier screening approach leading to a significant reduction of invasive diagnostic procedures. For women with a negative cfDNA screening result, NT measurement has limited clinical utility. © 2017 John Wiley & Sons, Ltd.
Severson, Carl A; Pendharkar, Sachin R; Ronksley, Paul E; Tsai, Willis H
2015-01-01
To assess the ability of electronic health data and existing screening tools to identify clinically significant obstructive sleep apnea (OSA), as defined by symptomatic or severe OSA. The present retrospective cohort study of 1041 patients referred for sleep diagnostic testing was undertaken at a tertiary sleep centre in Calgary, Alberta. A diagnosis of clinically significant OSA or an alternative sleep diagnosis was assigned to each patient through blinded independent chart review by two sleep physicians. Predictive variables were identified from online questionnaire data, and diagnostic algorithms were developed. The performance of electronically derived algorithms for identifying patients with clinically significant OSA was determined. Diagnostic performance of these algorithms was compared with versions of the STOP-Bang questionnaire and adjusted neck circumference score (ANC) derived from electronic data. Electronic questionnaire data were highly sensitive (>95%) at identifying clinically significant OSA, but not specific. Sleep diagnostic testing-determined respiratory disturbance index was very specific (specificity ≥95%) for clinically relevant disease, but not sensitive (<35%). Derived algorithms had similar accuracy to the STOP-Bang or ANC, but required fewer questions and calculations. These data suggest that a two-step process using a small number of clinical variables (maximizing sensitivity) and objective diagnostic testing (maximizing specificity) is required to identify clinically significant OSA. When used in an online setting, simple algorithms can identify clinically relevant OSA with similar performance to existing decision rules such as the STOP-Bang or ANC.
Eeles, Eamonn; Gunn, Hayley; Sutt, Anna-Liisa; Pinsker, Donna; Flaws, Dylan; Jarrett, Paul; Lye, India; Fraser, John F
2018-06-01
Delirium is common in the intensive care unit (ICU), often affecting older patients. A bedside electronic tool has the potential to revolutionise delirium screening. Our group describe a novel approach to the design and development of delirium screening questions for the express purpose of use within an electronic device. Preliminary results are presented. Our group designed a series of tests which targeted the clinical criteria for delirium according to Diagnostic and Statistical Manual of Mental Disorders - Fifth Edition (DSM-5) criteria against predefined requirements, including applicability to older patients. Candidate questions, including tests of attention and awareness, were devised and then refined by an expert multidisciplinary group, including geriatricians. A scoring scheme was constructed, with testing to failure an indicator of delirium. The device was tested in healthy controls, aged 20-80 years, who were recorded as being without delirium. e-Screening for delirium requires a novel approach to instrument design but may revolutionise recognition of delirium in ICU. © 2018 AJA Inc.
von Fricken, Michael E.; Weppelmann, Thomas A.; Eaton, Will T.; Masse, Roseline; Beau de Rochars, Madsen V. E.; Okech, Bernard A.
2014-01-01
Administering primaquine (PQ) to treat malaria patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency can pose a serious risk of drug-induced hemolysis (DIH). New easy to use point-of-care rapid diagnostic tests are being developed as an alternative to labor-intensive spectrophotometric methods, but they require field testing before they can be used at scale. This study screened 456 participants in Gressier, Haiti using the Access Bio CareStart qualitative G6PD rapid detection test compared with the laboratory-based Trinity Biotech quantitative spectrophotometric assay. Findings suggest that the CareStart test was 90% sensitive for detecting individuals with severe deficiency and 84.8% sensitive for detecting individuals with moderate and severe deficiency compared with the Trinity Biotech assay. A high negative predictive value of 98.2% indicates excellent performance in determining those patients able to take PQ safely. The CareStart G6PD test holds much value for screening malaria patients to determine eligibility for PQ therapy. PMID:24778197
von Fricken, Michael E; Weppelmann, Thomas A; Eaton, Will T; Masse, Roseline; Beau de Rochars, Madsen V E; Okech, Bernard A
2014-07-01
Administering primaquine (PQ) to treat malaria patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency can pose a serious risk of drug-induced hemolysis (DIH). New easy to use point-of-care rapid diagnostic tests are being developed as an alternative to labor-intensive spectrophotometric methods, but they require field testing before they can be used at scale. This study screened 456 participants in Gressier, Haiti using the Access Bio CareStart qualitative G6PD rapid detection test compared with the laboratory-based Trinity Biotech quantitative spectrophotometric assay. Findings suggest that the CareStart test was 90% sensitive for detecting individuals with severe deficiency and 84.8% sensitive for detecting individuals with moderate and severe deficiency compared with the Trinity Biotech assay. A high negative predictive value of 98.2% indicates excellent performance in determining those patients able to take PQ safely. The CareStart G6PD test holds much value for screening malaria patients to determine eligibility for PQ therapy. © The American Society of Tropical Medicine and Hygiene.
Human Papillomavirus Laboratory Testing: the Changing Paradigm
2016-01-01
SUMMARY High-risk human papillomaviruses (HPVs) cause essentially all cervical cancers, most anal and oropharyngeal cancers, and some vaginal, vulvar, and penile cancers. Improved understanding of the pathogenesis of infection and the availability of newer tests are changing the approach to screening and diagnosis. Molecular tests to detect DNA from the most common high-risk HPVs are FDA approved for use in conjunction with cytology in cervical cancer screening programs. More-specific tests that detect RNA from high-risk HPV types are now also available. The use of molecular tests as the primary screening tests is being adopted in some areas. Genotyping to identify HPV16 and -18 has a recommended role in triaging patients for colposcopy who are high-risk HPV positive but have normal cytology. There are currently no recommended screening methods for anal, vulvar, vaginal, penile, or oropharyngeal HPV infections. HPV testing has limited utility in patients at high risk for anal cancer, but p16 immunohistochemistry is recommended to clarify lesions in tissue biopsy specimens that show moderate dysplasia or precancer mimics. HPV testing is recommended for oropharyngeal squamous cell tumors as a prognostic indicator. Ongoing research will help to improve the content of future guidelines for screening and diagnostic testing. PMID:26912568
Vijayan, Tara; Klausner, Jeffrey D.
2014-01-01
The success of antiretroviral therapy (ART) programs in the developing world is limited by the lack of adequate diagnostic tests to screen for life-threatening opportunistic infections such as tuberculosis (TB) and cryptococcal disease. Furthermore, there is an increasing need for implementation research in measuring the effectiveness of currently available rapid diagnostic tests. The recently developed lateral flow assays for both cryptococcal disease and TB have the potential to improve care and greatly reduce the time to initiation of ART among individuals who need it the most. However, we caution that the data on feasibility and effectiveness of these assays are limited and such research agendas must be prioritized. PMID:24065780
Sperandio, Evandro Fornias; Arantes, Rodolfo Leite; da Silva, Rodrigo Pereira; Matheus, Agatha Caveda; Lauria, Vinícius Tonon; Bianchim, Mayara Silveira; Romiti, Marcello; Gagliardi, Antônio Ricardo de Toledo; Dourado, Victor Zuniga
2016-01-01
Accelerometry provides objective measurement of physical activity levels, but is unfeasible in clinical practice. Thus, we aimed to identify physical fitness tests capable of predicting physical inactivity among adults. Diagnostic test study developed at a university laboratory and a diagnostic clinic. 188 asymptomatic subjects underwent assessment of physical activity levels through accelerometry, ergospirometry on treadmill, body composition from bioelectrical impedance, isokinetic muscle function, postural balance on a force platform and six-minute walk test. We conducted descriptive analysis and multiple logistic regression including age, sex, oxygen uptake, body fat, center of pressure, quadriceps peak torque, distance covered in six-minute walk test and steps/day in the model, as predictors of physical inactivity. We also determined sensitivity (S), specificity (Sp) and area under the curve of the main predictors by means of receiver operating characteristic curves. The prevalence of physical inactivity was 14%. The mean number of steps/day (≤ 5357) was the best predictor of physical inactivity (S = 99%; Sp = 82%). The best physical fitness test was a distance in the six-minute walk test and ≤ 96% of predicted values (S = 70%; Sp = 80%). Body fat > 25% was also significant (S = 83%; Sp = 51%). After logistic regression, steps/day and distance in the six-minute walk test remained predictors of physical inactivity. The six-minute walk test should be included in epidemiological studies as a simple and cheap tool for screening for physical inactivity.
Backscatter from metal surfaces in diagnostic radiology.
Kodera, Y; Schmidt, R A; Chan, H P; Doi, K
1984-01-01
Backscatter from four commonly used metals (aluminum, lead, copper, and iron) was measured under diagnostic imaging conditions, using screen-film systems as detectors. The results indicate that for an 80-kV filtered beam and Par Speed/XRP system, backscatter increases as aluminum (Al) thickness increases until it reaches a plateau of approximately 12% at 50 mm Al. The amount of backscatter from any of these four metals increases as the tube voltage is raised from 60 to 115 kV. Measured backscatter depends strongly on the screens used, possibly due to their attenuation and energy response. Backscatter from aluminum was significantly greater than that from the other metals tested.
Diagnosis of Helicobacter pylori infection: Current options and developments
Wang, Yao-Kuang; Kuo, Fu-Chen; Liu, Chung-Jung; Wu, Meng-Chieh; Shih, Hsiang-Yao; Wang, Sophie SW; Wu, Jeng-Yih; Kuo, Chao-Hung; Huang, Yao-Kang; Wu, Deng-Chyang
2015-01-01
Accurate diagnosis of Helicobacter pylori (H. pylori) infection is a crucial part in the effective management of many gastroduodenal diseases. Several invasive and non-invasive diagnostic tests are available for the detection of H. pylori and each test has its usefulness and limitations in different clinical situations. Although none can be considered as a single gold standard in clinical practice, several techniques have been developed to give the more reliable results. Invasive tests are performed via endoscopic biopsy specimens and these tests include histology, culture, rapid urease test as well as molecular methods. Developments of endoscopic equipment also contribute to the real-time diagnosis of H. pylori during endoscopy. Urea breathing test and stool antigen test are most widely used non-invasive tests, whereas serology is useful in screening and epidemiological studies. Molecular methods have been used in variable specimens other than gastric mucosa. More than detection of H. pylori infection, several tests are introduced into the evaluation of virulence factors and antibiotic sensitivity of H. pylori, as well as screening precancerous lesions and gastric cancer. The aim of this article is to review the current options and novel developments of diagnostic tests and their applications in different clinical conditions or for specific purposes. PMID:26523098
Nanotechnology-Based Surface Plasmon Resonance Affinity Biosensors for In Vitro Diagnostics
Antiochia, Riccarda; Bollella, Paolo; Favero, Gabriele
2016-01-01
In the last decades, in vitro diagnostic devices (IVDDs) became a very important tool in medicine for an early and correct diagnosis, a proper screening of targeted population, and also assessing the efficiency of a specific therapy. In this review, the most recent developments regarding different configurations of surface plasmon resonance affinity biosensors modified by using several nanostructured materials for in vitro diagnostics are critically discussed. Both assembly and performances of the IVDDs tested in biological samples are reported and compared. PMID:27594884
Main, C; Moxham, T; Wyatt, J C; Kay, J; Anderson, R; Stein, K
2010-10-01
Order communication systems (OCS) are computer applications used to enter diagnostic and therapeutic patient care orders and to view test results. Many potential benefits of OCS have been identified including improvements in clinician ordering patterns, optimisation of clinical time, and aiding communication processes between clinicians and different departments. Many OCS now include computerised decision support systems (CDSS), which are information systems designed to improve clinical decision-making. CDSS match individual patient characteristics to a computerised knowledge base, and software algorithms generate patient-specific recommendations. To investigate which CDSS in OCS are in use within the UK and the impact of CDSS in OCS for diagnostic, screening or monitoring test ordering compared to OCS without CDSS. To determine what features of CDSS are associated with clinician or patient acceptance of CDSS in OCS and what is known about the cost-effectiveness of CDSS in diagnostic, screening or monitoring test OCS compared to OCS without CDSS. A generic search to identify potentially relevant studies for inclusion was conducted using MEDLINE, EMBASE, Cochrane Controlled Trials Register (CCTR), CINAHL (Cumulative Index to Nursing and Allied Health Literature), DARE (Database of Abstracts of Reviews of Effects), Health Technology Assessment (HTA) database, IEEE (Institute of Electrical and Electronic Engineers) Xplore digital library, NHS Economic Evaluation Database (NHS EED) and EconLit, searched between 1974 and 2009 with a total of 22,109 titles and abstracts screened for inclusion. CDSS for diagnostic, screening and monitoring test ordering OCS in use in the UK were identified through contact with the 24 manufacturers/suppliers currently contracted by the National Project for Information Technology (NpfIT) to provide either national or specialist decision support. A generic search to identify potentially relevant studies for inclusion in the review was conducted on a range of medical, social science and economic databases. The review was undertaken using standard systematic review methods, with studies being screened for inclusion, data extracted and quality assessed by two reviewers. Results were broadly grouped according to the type of CDSS intervention and study design where possible. These were then combined using a narrative synthesis with relevant quantitative results tabulated. Results of the studies included in review were highly mixed and equivocal, often both within and between studies, but broadly showed a beneficial impact of the use of CDSS in conjunction with OCS over and above OCS alone. Overall, if the findings of both primary and secondary outcomes are taken into account, then CDSS significantly improved practitioner performance in 15 out of 24 studies (62.5%). Only two studies covered the cost-effectiveness of CDSS: a Dutch study reported a mean cost decrease of 3% for blood tests orders (639 euros) in each of the intervention clinics compared with a 2% (208 euros) increase in control clinics in test costs; and a Spanish study reported a significant increase in the cost of laboratory tests from 41.8 euros per patient per annum to 47.2 euros after implementation of the system. The response rate from the survey of manufacturers and suppliers was extremely low at only 17% and much of the feedback was classified as being commercial-in-confidence (CIC). No studies were identified which assessed the features of CDSS that are associated with clinician or patient acceptance of CDSS in OCS in the test ordering process and only limited data was available on the cost-effectiveness of CDSS plus OCS compared with OCS alone and the findings highly specific. Although CDSS appears to have a potentially small positive impact on diagnostic, screening or monitoring test ordering, the majority of studies come from a limited number of institutions in the USA. If the findings of both primary and secondary outcomes are taken into account then CDSS showed a statistically significant benefit on either process or practitioner performance outcomes in nearly two-thirds of the studies. Furthermore, in four studies that assessed adverse effects of either test cancellation or delay, no significant detrimental effects in terms of additional utilisation of health-care resources or adverse events were observed. We believe the key current need is for a well designed and comprehensive survey, and on the basis of the results of this potentially for evaluation studies in the form of cluster randomised controlled trials or randomised controlled trials which incorporate process, and patient outcomes, as well as full economic evaluations alongside the trials to assess the impact of CDSS in conjunction with OCS versus OCS alone for diagnostic, screening or monitoring test ordering in the NHS. The economic evaluation should incorporate the full costs of potentially developing, testing, and installing the system, including staff training costs. Study registration 61.
Lacbawan, Felicitas L; Weck, Karen E; Kant, Jeffrey A; Feldman, Gerald L; Schrijver, Iris
2012-01-01
The number of clinical laboratories introducing various molecular tests to their existing test menu is continuously increasing. Prior to offering a US Food and Drug Administration-approved test, it is necessary that performance characteristics of the test, as claimed by the company, are verified before the assay is implemented in a clinical laboratory. To provide an example of the verification of a specific qualitative in vitro diagnostic test: cystic fibrosis carrier testing using the Luminex liquid bead array (Luminex Molecular Diagnostics, Inc, Toronto, Ontario). The approach used by an individual laboratory for verification of a US Food and Drug Administration-approved assay is described. Specific verification data are provided to highlight the stepwise verification approach undertaken by a clinical diagnostic laboratory. Protocols for verification of in vitro diagnostic assays may vary between laboratories. However, all laboratories must verify several specific performance specifications prior to implementation of such assays for clinical use. We provide an example of an approach used for verifying performance of an assay for cystic fibrosis carrier screening.
Maxwell, Susannah; Dickinson, Jan E; Murch, Ashleigh; O'Leary, Peter
2015-10-01
To describe the potential impact of using noninvasive prenatal testing (NIPT) as a second-tier test, on the diagnosis and outcomes of pregnancies identified as high risk through first trimester screening (FTS) in a cohort of real pregnancies. Western Australian FTS and diagnostic data (2007-2009) were linked to pregnancy outcomes. Karyotype results from invasive prenatal testing in high-risk women were analysed. The outcomes of abnormal results that would not be detected by NIPT, assuming a panel of trisomy 21/18/13 and sex chromosome aneuploidies, and the likelihood of diagnosis in a screening model using NIPT as a second-tier test are described. Abnormal karyotype results were reported in 224 of 1488 (15%) women with high-risk pregnancies having invasive diagnostic testing. NIPT potentially would have identified 85%. The 33 abnormalities unidentifiable by NIPT were triploidies (n = 7, 21%), balanced (n = 8, 24%) and unbalanced rearrangements (n = 10, 30%) and level III mosaicisms (n = 8, 24%). For conditions not identifiable by NIPT, fetal sonographic appearance was likely to have led to invasive testing for 10 of 17 (59%) pathogenic abnormalities. If a policy was adopted recommending invasive testing for FTS risk >1:50 and/or ultrasound detected abnormality, the residual risk of an unidentified pathogenic chromosomal abnormality in those without a diagnosis would have been 0.33% (95% CI 0.01-0.65%). A screening model with NIPT as a second-tier for high-risk pregnancies would be unlikely to have changed the outcome for the majority of pregnancies. Optimising the diagnosis of rare pathogenic abnormalities requires clear indicators for invasive testing over NIPT. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
[Mammography screening of breast cancer in Tunisia. Results of first experience].
Kribi, Lilia; Sellami, Dorra; el Amri, Aïda; Mnif, Nejla; Ellouze, Thouraya; Chebbi, Ali; Ben Romdhane, Khaled; Hamza, Radhi
2003-01-01
This article reports the results of a mammography screening program of breast cancer, realized in the department of Radiology, Charles Nicolle hospital. A free screening mammography with two incidences was offered to women aged from 40 to 70 years old. 2200 mammographies were realized from May 1995 till July 1997. Women having a positive test benefited of a diagnostic explorations in the same unity. The positive test rate was 24%. Predictive positive value was 31%. This program allowed to detect 10 subclinical cancers, corresponding to a rate of detection of 4.5 cancers for 1000 women. This program is a first experience which demonstrated the feasibility of the mammography screening to wide scale and allowed the medical and paramedical team to acquire an experience.
Physiologic Screening Test for Eating Disorders/Disordered Eating Among Female Collegiate Athletes.
Black, David R.; Larkin, Laurie J.S.; Coster, Daniel C.; Leverenz, Larry J.; Abood, Doris A.
2003-12-01
OBJECTIVE: To develop and evaluate a physiologic screening test specifically designed for collegiate female athletes engaged in athletic competition or highly athletic performances in order to detect eating disorders/disordered eating. No such physiologically based test currently exists. METHODS: Subjects included 148 (84.5%) of 175 volunteer, National Collegiate Athletic Association Division I (n = 92), club (n = 15), and dance team (n = 41) athletes 18 to 25 years old who attended a large, Midwestern university. Participants completed 4 tests: 2 normed for the general population (Eating Disorders Inventory-2 and Bulimia Test-Revised); a new physiologic test, developed and pilot tested by the investigators, called the Physiologic Screening Test; and the Eating Disorder Exam 12.0D, a structured, validated, diagnostic interview used for criterion validity. RESULTS: The 18-item Physiologic Screening Test produced the highest sensitivity (87%) and specificity (78%) and was superior to the Eating Disorders Inventory-2 (sensitivity = 62%, specificity = 74%) and Bulimia Test-Revised (sensitivity = 27%, specificity = 99%). A substantial number (n = 51, 35%) of athletes were classified as eating disordered/disordered eating. CONCLUSIONS: The Physiologic Screening Test should be considered for screening athletes for eating disorders/disordered eating. The Physiologic Screening Test seems to be a viable alternative to existing tests because it is specifically designed for female athletes, it is brief (4 measurements and 14 items), and validity is enhanced and response bias is lessened because the purpose is less obvious, especially when included as part of a mandatory preparticipation examination.
Bush, Matthew L; Taylor, Zachary R; Noblitt, Bryce; Shackleford, Taylor; Gal, Thomas J; Shinn, Jennifer B; Creel, Liza M; Lester, Cathy; Westgate, Philip M; Jacobs, Julie A; Studts, Christina R
2017-11-01
To assess the efficacy of a patient navigator intervention to decrease nonadherence to obtain audiological testing following failed screening, compared to those receiving the standard of care. Using a randomized controlled design, guardian-infant dyads, in which the infants had abnormal newborn hearing screening, were recruited within the first week after birth. All participants were referred for definitive audiological diagnostic testing. Dyads were randomized into a patient navigator study arm or standard of care arm. The primary outcome was the percentage of patients with follow-up nonadherence to obtain diagnostic testing. Secondary outcomes were parental knowledge of infant hearing testing recommendations and barriers in obtaining follow-up testing. Sixty-one dyads were enrolled in the study (patient navigator arm = 27, standard of care arm = 34). The percentage of participants nonadherent to diagnostic follow-up during the first 6 months after birth was significantly lower in the patient navigator arm compared with the standard of care arm (7.4% vs. 38.2%) (P = .005). The timing of initial follow-up was significantly lower in the navigator arm compared with the standard of care arm (67.9 days after birth vs. 105.9 days, P = .010). Patient navigation increased baseline knowledge regarding infant hearing loss diagnosis recommendations compared with the standard of care (P = .004). Patient navigation decreases nonadherence rates following abnormal infant hearing screening and improves knowledge of follow-up recommendations. This intervention has the potential to improve the timeliness of delivery of infant hearing healthcare; future research is needed to assess the cost and feasibility of larger scale implementation. 1b. Laryngoscope, 127:S1-S13, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Cost-effectiveness of Chlamydia antibody tests in subfertile women.
Fiddelers, A A A; Land, J A; Voss, G; Kessels, A G H; Severens, J L
2005-02-01
For the evaluation of tubal function, Chlamydia antibody testing (CAT) has been introduced as a screening test. We compared six CAT screening strategies (five CAT tests and one combination of tests), with respect to their cost-effectiveness, by using IVF pregnancy rate as outcome measure. A decision analytic model was developed based on a source population of 1715 subfertile women. The model incorporates hysterosalpingography (HSG), laparoscopy and IVF. To calculate IVF pregnancy rates, costs, effects, cost-effectiveness and incremental costs per effect of the six different CAT screening strategies were determined. pELISA Medac turned out to be the most cost-effective CAT screening strategy (15 075 per IVF pregnancy), followed by MIF Anilabsystems (15 108). A combination of tests (pELISA Medac and MIF Anilabsystems; 15 127) did not improve the cost-effectiveness of the single strategies. Sensitivity analyses showed that the results are robust for changes in the baseline values of the model parameters. Only small differences were found between the screening strategies regarding the cost-effectiveness, although pELISA Medac was the most cost-effective strategy. Before introducing a particular CAT test into clinical practice, one should consider the effects and consequences of the entire screening strategy, instead of only the diagnostic accuracy of the test used.
Newborn screening for cystic fibrosis - The parent perspective.
Rueegg, Corina S; Barben, Jürg; Hafen, Gaudenz M; Moeller, Alexander; Jurca, Maja; Fingerhut, Ralph; Kuehni, Claudia E
2016-07-01
Newborn screening for CF started 01/2011 in Switzerland. We investigated the parents' opinions about the information received, their feelings, and overall approval of the screening. This is a prospective questionnaire survey of all parents of positively screened children. Parents were phoned by CF-centres and invited for diagnostic investigations. They completed a questionnaire after the visit to the CF-centre. From 2011-2013, 246 families received the questionnaire and 138 (56%) replied. Of these 77 (60%) found the information received at birth satisfactory; 124 (91%) found the information provided in the CF-centre satisfactory. Most parents (n=98, 78%) felt troubled or anxious when the CF-centre called, 51 (38%) remained anxious after the visit. Most parents (n=122; 88%) were satisfied with the screening, 4 (3%) were not, and 12 (9%) were unsure. The smooth organisation of the screening process, with personal information by a CF specialist and short delays between this information and the final diagnostic testing, might have contributed to reduce anxiety among parents. Most families were grateful that their child had been screened, and are happy with the process. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Li, Mei; Li, Jun; Xia, Zhigui; Xiao, Ning; Jiang, Weikang; Wen, Yongkang
2017-04-30
Early and accurate diagnosis of imported malaria cases in clusters is crucial for protecting the health of patients and local populations, especially confirmed parasitic persons who are asymptomatic. A total of 226 gold miners who had stayed in highly endemic areas of Ghana for more than six months and returned in clusters were selected randomly. Blood samples from them were tested with microscopy, nest polymerase chain reaction, and rapid diagnostic test (RDT). The sensitivity, specificity, predictive values, agreement rate, and Youden's index of each of three diagnostic methods were calculated and compared with the defined gold standard. A quick and efficient way to respond to screening such a clustered mobile population was predicted and analyzed by evaluating two assumed results of combining microscopy and RDT with or without symptoms of illness. The rate of the carriers of malaria parasites in the populations of gold miners was 19.47%, including 39 P. falciparum. Among the three diagnostic methods, the microscopy method showed the highest specificity, while the RDT method showed the highest sensitivity but the lowest specificity in detecting P. falciparum. The assumed results of combining RDT and microscopy with symptoms showed the best results among all the test results in screening P. falciparum. It was too complex and difficult to catch all parasite carriers in a short period of time among populations with such a complicated situation as that in Shanglin County. A strategy of combing microscopy and RDT for diagnosis is highly recommended.
Radiologists’ Interpretive Skills in Screening vs. Diagnostic Mammography: Are They Related?
Elmore, Joann G.; Cook, Andrea J.; Bogart, Andy; Carney, Patricia A.; Geller, Berta; Taplin, Stephen; Buist, Diana SM; Onega, Tracy; Lee, Christoph I.; Miglioretti, Diana L.
2016-01-01
Purpose To determine whether radiologists who perform well in screening also perform well in interpreting diagnostic mammography. Materials & Methods We evaluated the accuracy of 468 radiologists interpreting 2,234,947 screening and 196,164 diagnostic mammograms. Adjusting for site, radiologist, and patient characteristics, we identified radiologists with performance in the highest tertile and compared to those with lower performance. Results A moderate correlation was noted for radiologists’ accuracy when interpreting screening versus their accuracy on diagnostic exams: sensitivity (rspearman=0.51, 95% CI: 0.22, 0.80; P=0.0006), specificity (rspearman=0.40, 95% CI: 0.30, 0.49; P<0.0001). Conclusion Different educational approaches to screening and diagnostic imaging should be considered. PMID:27438069
Multiplex PCR Tests for Detection of Pathogens Associated with Gastroenteritis
Zhang, Hongwei; Morrison, Scott; Tang, Yi-Wei
2016-01-01
Synopsis A wide range of enteric pathogens can cause infectious gastroenteritis. Conventional diagnostic algorithms including culture, biochemical identification, immunoassay and microscopic examination are time consuming and often lack sensitivity and specificity. Advances in molecular technology have as allowed its use as clinical diagnostic tools. Multiplex PCR based testing has made its way to gastroenterology diagnostic arena in recent years. In this article we present a review of recent laboratory developed multiplex PCR tests and current commercial multiplex gastrointestinal pathogen tests. We will focus on two FDA cleared commercial syndromic multiplex tests: Luminex xTAG GPP and Biofire FimArray GI test. These multiplex tests can detect and identify multiple enteric pathogens in one test and provide results within hours. Multiplex PCR tests have shown superior sensitivity to conventional methods for detection of most pathogens. The high negative predictive value of these multiplex tests has led to the suggestion that they be used as screening tools especially in outbreaks. Although the clinical utility and benefit of multiplex PCR test are to be further investigated, implementing these multiplex PCR tests in gastroenterology diagnostic algorithm has the potential to improve diagnosis of infectious gastroenteritis. PMID:26004652
C.R. Lane; E. Hobden; L. Laurenson; V.C. Barton; K.J.D. Hughes; H. Swan; N. Boonham; A.J. Inman
2008-01-01
Plant health regulations to prevent the introduction and spread of Phytophthora ramorum and P. kernoviae require rapid, cost effective diagnostic methods for screening large numbers of plant samples at the time of inspection. Current on-site techniques require expensive equipment, considerable expertise and are not suited for plant...
Diagnosis of Periodontal Diseases: Building a Bridge from Today's Methods to Tomorrow's Technology.
ERIC Educational Resources Information Center
Jeffcoat, Marjorie K.
1994-01-01
A discussion of advancements in diagnosis of periodontal diseases looks first at the screening process, reviews specific periodontal diseases and their clinical signs and symptoms, and explains both traditional and newly developed diagnostic tests. A framework for understanding the tests' clinical usefulness is also presented. (MSE)
Hierarchical screening for multiple mental disorders.
Batterham, Philip J; Calear, Alison L; Sunderland, Matthew; Carragher, Natacha; Christensen, Helen; Mackinnon, Andrew J
2013-10-01
There is a need for brief, accurate screening when assessing multiple mental disorders. Two-stage hierarchical screening, consisting of brief pre-screening followed by a battery of disorder-specific scales for those who meet diagnostic criteria, may increase the efficiency of screening without sacrificing precision. This study tested whether more efficient screening could be gained using two-stage hierarchical screening than by administering multiple separate tests. Two Australian adult samples (N=1990) with high rates of psychopathology were recruited using Facebook advertising to examine four methods of hierarchical screening for four mental disorders: major depressive disorder, generalised anxiety disorder, panic disorder and social phobia. Using K6 scores to determine whether full screening was required did not increase screening efficiency. However, pre-screening based on two decision tree approaches or item gating led to considerable reductions in the mean number of items presented per disorder screened, with estimated item reductions of up to 54%. The sensitivity of these hierarchical methods approached 100% relative to the full screening battery. Further testing of the hierarchical screening approach based on clinical criteria and in other samples is warranted. The results demonstrate that a two-phase hierarchical approach to screening multiple mental disorders leads to considerable increases efficiency gains without reducing accuracy. Screening programs should take advantage of prescreeners based on gating items or decision trees to reduce the burden on respondents. © 2013 Elsevier B.V. All rights reserved.
Cettomai, Deanna; Kwasa, Judith; Kendi, Caroline; Birbeck, Gretchen L; Price, Richard W; Bukusi, Elizabeth A; Cohen, Craig R; Meyer, Ana-Claire
2010-12-08
Neuropathy is the most common neurologic complication of HIV but is widely under-diagnosed in resource-constrained settings. We aimed to identify tools that accurately distinguish individuals with moderate/severe peripheral neuropathy and can be administered by non-physician healthcare workers (HCW) in resource-constrained settings. We enrolled a convenience sample of 30 HIV-infected outpatients from a Kenyan HIV-care clinic. A HCW administered the Neuropathy Severity Score (NSS), Single Question Neuropathy Screen (Single-QNS), Subjective Peripheral Neuropathy Screen (Subjective-PNS), and Brief Peripheral Neuropathy Screen (Brief-PNS). Monofilament, graduated tuning fork, and two-point discrimination examinations were performed. Tools were validated against a neurologist's clinical assessment of moderate/severe neuropathy. The sample was 57% male, mean age 38.6 years, and mean CD4 count 324 cells/µL. Neurologist's assessment identified 20% (6/30) with moderate/severe neuropathy. Diagnostic utilities for moderate/severe neuropathy were: Single-QNS--83% sensitivity, 71% specificity; Subjective-PNS-total--83% sensitivity, 83% specificity; Subjective-PNS-max and NSS--67% sensitivity, 92% specificity; Brief-PNS--0% sensitivity, 92% specificity; monofilament--100% sensitivity, 88% specificity; graduated tuning fork--83% sensitivity, 88% specificity; two-point discrimination--75% sensitivity, 58% specificity. Pilot testing suggests Single-QNS, Subjective-PNS, and monofilament examination accurately identify HIV-infected patients with moderate/severe neuropathy and may be useful diagnostic tools in resource-constrained settings.
Drain, Paul K; Losina, Elena; Coleman, Sharon M; Giddy, Janet; Ross, Douglas; Katz, Jeffrey N; Walensky, Rochelle P; Freedberg, Kenneth A; Bassett, Ingrid V
2014-02-26
A rapid diagnostic test for active tuberculosis (TB) at the clinical point-of-care could expedite case detection and accelerate TB treatment initiation. We assessed the diagnostic accuracy of a rapid urine lipoarabinomannan (LAM) test for TB screening among HIV-infected adults in a TB-endemic setting. We prospectively enrolled newly-diagnosed HIV-infected adults (≥18 years) at 4 outpatient clinics in Durban from Oct 2011-May 2012, excluding those on TB therapy. A physician evaluated all participants and offered CD4 cell count testing. Trained study nurses collected a sputum sample for acid-fast bacilli smear microscopy (AFB) and mycobacterial culture, and performed urine LAM testing using Determine™ TB LAM in the clinic. The presence of a band regardless of intensity on the urine LAM test was considered positive. We defined as the gold standard for active pulmonary TB a positive sputum culture for Mycobacterium tuberculosis. Diagnostic accuracy of urine LAM was assessed, alone and in combination with smear microscopy, and stratified by CD4 cell count. Among 342 newly-diagnosed HIV-infected participants, 190 (56%) were male, mean age was 35.6 years, and median CD4 was 182/mm3. Sixty participants had culture-positive pulmonary TB, resulting in an estimated prevalence of 17.5% (95% CI 13.7-22.0%). Forty-five (13.2%) participants were urine LAM positive. Mean time from urine specimen collection to LAM test result was 40 minutes (95% CI 34-46 minutes). Urine LAM test sensitivity was 28.3% (95% CI 17.5-41.4) overall, and 37.5% (95% CI 21.1-56.3) for those with CD4 count <100/mm3, while specificity was 90.1% (95% CI 86.0-93.3) overall, and 86.9% (95% CI 75.8-94.2) for those with CD4 < 100/mm3. When combined with sputum AFB (either test positive), sensitivity increased to 38.3% (95% CI 26.0-51.8), but specificity decreased to 85.8% (95% CI 81.1-89.7). In this prospective, clinic-based study with trained nurses, a rapid urine LAM test had low sensitivity for TB screening among newly-diagnosed HIV-infected adults, but improved sensitivity when combined with sputum smear microscopy.
[Evaluation of quality of HIV diagnostic procedures in Poland].
Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna
2010-01-01
The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.
Govindarajan, S.; Sharath, B. N.; Tripathy, J. P.; Chinnakali, P.; Kumar, A. M. V.; Muthaiah, M.; Vivekananda, K.; Paulraj, A. K.; Roy, G.
2015-01-01
Setting: The Revised National Tuberculosis Control Programme, Puducherry, India, which has facilities for molecular diagnostic technique. Objective: To determine pre-diagnostic and pre-treatment attrition among presumptive multidrug-resistant tuberculosis (MDR-TB) patients and reasons for attrition. Methods: In this mixed-methods study, the quantitative component consisted of retrospective cohort analysis through record review of all presumptive MDR-TB patients recorded between October 2012 and September 2013. The qualitative component included in-depth interviews with key informants involved in programmatic management of drug-resistant tuberculosis services. Results: Of 341 eligible presumptive MDR-TB patients, pre-diagnostic and pre-treatment attrition was respectively 45.5% (155/341) and 29% (2/7). Patients with extra-pulmonary TB (RR = 2.3), those with human immuno-deficiency and TB co-infection (RR = 1.7), those registered during October–December 2012 (RR = 1.3) and those identified from primary/secondary health centres (RR = 1.8) were less likely to be tested. Themes that emerged during the analysis of the qualitative data were ‘lack of a systematic mechanism to track referrals for culture and drug susceptibility testing’, ‘absence of courier service to transport sputum’, ‘lack of knowledge and ownership among staff of general health system’, ‘shortage of diagnostic kits’ and ‘patient non-adherence’. Conclusion: Despite the introduction of molecular diagnostic techniques, operational issues in MDR-TB screening remain a concern and require urgent attention. PMID:26400385
Kuppermann, Miriam; Pena, Sherri; Bishop, Judith T; Nakagawa, Sanae; Gregorich, Steven E; Sit, Anita; Vargas, Juan; Caughey, Aaron B; Sykes, Susan; Pierce, Lasha; Norton, Mary E
2014-09-24
Prenatal genetic testing guidelines recommend providing patients with detailed information to allow informed, preference-based screening and diagnostic testing decisions. The effect of implementing these guidelines is not well understood. To analyze the effect of a decision-support guide and elimination of financial barriers to testing on use of prenatal genetic testing and decision making among pregnant women of varying literacy and numeracy levels. Randomized trial conducted from 2010-2013 at prenatal clinics at 3 county hospitals, 1 community clinic, 1 academic center, and 3 medical centers of an integrated health care delivery system in the San Francisco Bay area. Participants were English- or Spanish-speaking women who had not yet undergone screening or diagnostic testing and remained pregnant at 11 weeks' gestation (n = 710). A computerized, interactive decision-support guide and access to prenatal testing with no out-of-pocket expense (n = 357) or usual care as per current guidelines (n = 353). The primary outcome was invasive diagnostic test use, obtained via medical record review. Secondary outcomes included testing strategy undergone, and knowledge about testing, risk comprehension, and decisional conflict and regret at 24 to 36 weeks' gestation. Women randomized to the intervention group, compared with those randomized to the control group, were less likely to have invasive diagnostic testing (5.9% vs 12.3%; odds ratio [OR], 0.45 [95% CI, 0.25-0.80]) and more likely to forgo testing altogether (25.6% vs 20.4%; OR, 3.30 [95% CI, 1.43-7.64], reference group screening followed by invasive testing). Women randomized to the intervention group also had higher knowledge scores (9.4 vs 8.6 on a 15-point scale; mean group difference, 0.82 [95% CI, 0.34-1.31]) and were more likely to correctly estimate the amniocentesis-related miscarriage risk (73.8% vs 59.0%; OR, 1.95 [95% CI, 1.39-2.75]) and their estimated age-adjusted chance of carrying a fetus with trisomy 21 (58.7% vs 46.1%; OR, 1.66 [95% CI, 1.22-2.28]). Significant differences did not emerge in decisional conflict or regret. Full implementation of prenatal testing guidelines using a computerized, interactive decision-support guide in the absence of financial barriers to testing resulted in less test use and more informed choices. If validated in additional populations, this approach may result in more informed and preference-based prenatal testing decision making and fewer women undergoing testing. clinicaltrials.gov Identifier: NCT00505596.
Code of Federal Regulations, 2011 CFR
2011-04-01
... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IN VITRO DIAGNOSTIC PRODUCTS FOR HUMAN USE Requirements for Manufacturers and Producers § 809.40... set forth in this section. (b) Sample testing shall be performed in a laboratory using screening tests...
Code of Federal Regulations, 2010 CFR
2010-04-01
... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IN VITRO DIAGNOSTIC PRODUCTS FOR HUMAN USE Requirements for Manufacturers and Producers § 809.40... set forth in this section. (b) Sample testing shall be performed in a laboratory using screening tests...
ERIC Educational Resources Information Center
Koppitz, Elizabeth Munsterberg
Presented is a manual for scoring the Bender Gestalt Test and the Human Figure Drawing Test for screening and diagnostic uses with emotionally disturbed, brain damaged, or perceptually handicapped 5- to 11-year-old children. Given are suggestions for administering and scoring the Bender test which examines distortion of shape, rotation,…
Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M
2017-07-01
Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.
Acquired Cystic Kidney Disease
... care provider about when to begin screening. Eating, Diet, and Nutrition No specific diet will prevent or delay acquired ... Weight Management Liver Disease Urologic Diseases Endocrine Diseases Diet & Nutrition Blood Diseases Diagnostic Tests La información de la ...
Barrio, Pablo; Teixidor, Lídia; Ortega, Lluisa; Lligoña, Anna; Rico, Nayra; Bedini, José Luis; Vieta, Eduard; Gual, Antoni
2018-02-01
Efforts aimed at reducing alcohol-related harm include early detection of risky drinkers as well as detection of early relapse in patients with alcohol dependence. Ethyl glucuronide (EtG) has been proven to be a reliable biomarker for the detection of recent drinking; however, no randomized, diagnostic trial to date has tested its impact on drinking outcomes. The aim of this study was to assess, in a randomized design, the implications of EtG screening on alcohol outcomes, compared to screening with a low sensitivity biomarker such as ethanol. Alcohol dependent outpatients were randomized to either 24 weeks of continuous screening with EtG or ethanol. Patients were aware of screening methods and results. After 24 weeks, all participants were screened with EtG. Self-reports were also gathered. A logistic regression compared the rate of EtG positive results at study end between groups. Generalized estimating equations evaluated the descending monthly rate of EtG positive patients in the EtG group. A total of 162 patients were randomized. During the study period, the ethanol group showed less patients with positive screens (19/64 (29.7%) vs 58/98 (59%)). After 24 weeks, the EtG group showed a greater number of patients having a negative screening test compared to ethanol subjects when they were all screened with EtG (5/62 (8.1%) vs 13/39 (33.3%)). A significant decrease in the rate of EtG positive patients was found for the first three months of the study. Routine screening with EtG seems to reduce drinking and improve abstinence rates in alcohol dependent outpatients. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhong, Qiu-Yue; Karlson, Elizabeth W; Gelaye, Bizu; Finan, Sean; Avillach, Paul; Smoller, Jordan W; Cai, Tianxi; Williams, Michelle A
2018-05-29
We examined the comparative performance of structured, diagnostic codes vs. natural language processing (NLP) of unstructured text for screening suicidal behavior among pregnant women in electronic medical records (EMRs). Women aged 10-64 years with at least one diagnostic code related to pregnancy or delivery (N = 275,843) from Partners HealthCare were included as our "datamart." Diagnostic codes related to suicidal behavior were applied to the datamart to screen women for suicidal behavior. Among women without any diagnostic codes related to suicidal behavior (n = 273,410), 5880 women were randomly sampled, of whom 1120 had at least one mention of terms related to suicidal behavior in clinical notes. NLP was then used to process clinical notes for the 1120 women. Chart reviews were performed for subsamples of women. Using diagnostic codes, 196 pregnant women were screened positive for suicidal behavior, among whom 149 (76%) had confirmed suicidal behavior by chart review. Using NLP among those without diagnostic codes, 486 pregnant women were screened positive for suicidal behavior, among whom 146 (30%) had confirmed suicidal behavior by chart review. The use of NLP substantially improves the sensitivity of screening suicidal behavior in EMRs. However, the prevalence of confirmed suicidal behavior was lower among women who did not have diagnostic codes for suicidal behavior but screened positive by NLP. NLP should be used together with diagnostic codes for future EMR-based phenotyping studies for suicidal behavior.
Ramlall, S; Chipps, J; Bhigjee, A I; Pillay, B J
2013-01-01
The effectiveness of dementia screening depends on the availability of suitable screening tools with good sensitivity and specificity to confidently distinguish normal age-related cognitive decline from dementia. The aim of this study was to evaluate the discriminant validity of 7 screening measures for dementia. A sample of 140 participants aged ≥60 years living in a residential facility for the aged were assessed clinically and assigned caseness for dementia using the Diagnostic and Statistical Manual of Mental Disorders, 4th edition, text revised diagnostic criteria. Sensitivity and specificity of a selection of the following screening measures were tested using receiver operating characteristic (ROC) analysis for individual and combined tests: the Mini-Mental State Examination (MMSE), Six-Item Screener (SIS), Subjective Memory Complaint, Subjective Memory Complaint Clinical (SMCC), Subjective Memory Rating Scale (SMRS), Deterioration Cognitive Observee (DECO) and the Clock Drawing Test (CDT). Using ROC analyses, the SMCC, MMSE and CDT were found to be 'moderately accurate' in screening for dementia with an area under the curve (AUC) >0.70. The AUCs for the SIS (0.526), SMRS (0.661) and DECO (0.687) classified these measures as being 'less accurate'. At recommended cutoff scores, the SMCC had a sensitivity of 90.9% and specificity of 45.7%; the MMSE had a sensitivity of 63.6% and a specificity of 76.0%, and the CDT had a sensitivity of 44.4% and a specificity of 88.9%. Combining the SMCC and MMSE did not improve their predictive power except for a modest increase when using the sequential rule. The SMCC is composed of valid screening questions that have high sensitivity, are simple to administer and ideal for administration at the community or primary health care level as a first level of 'rule-out' screening. The MMSE can be included at a second stage of screening at the general hospital level and the CDT in specialist clinical settings. Sequential use of the SMCC and MMSE will improve the specificity of the former and the sensitivity of the latter. Copyright © 2013 S. Karger AG, Basel.
Genetic screening and testing in an episode-based payment model: preserving patient autonomy.
Sutherland, Sharon; Farrell, Ruth M; Lockwood, Charles
2014-11-01
The State of Ohio is implementing an episode-based payment model for perinatal care. All costs of care will be tabulated for each live birth and assigned to the delivering provider, creating a three-tiered model for reimbursement for care. Providers will be reimbursed as usual for care that is average in cost and quality, while instituting rewards or penalties for those outside the expected range in either domain. There are few exclusions, and all methods of genetic screening and diagnostic testing are included in the episode cost calculation as proposed. Prenatal ultrasonography, genetic screening, and diagnostic testing are critical components of the delivery of high-quality, evidence-based prenatal care. These tests provide pregnant women with key information about the pregnancy, which, in turn, allows them to work closely with their health care provider to determine optimal prenatal care. The concepts of informed consent and decision-making, cornerstones of the ethical practice of medicine, are founded on the principles of autonomy and respect for persons. These principles recognize that patients' rights to make choices and take actions are based on their personal beliefs and values. Given the personal nature of such decisions, it is critical that patients have unbarred access to prenatal genetic tests if they elect to use them as part of their prenatal care. The proposed restructuring of reimbursement creates a clear conflict between patient autonomy and physician financial incentives.
Comparison of diagnostic techniques for the detection of Cryptosporidium oocysts in animal samples
Mirhashemi, Marzieh Ezzaty; Zintl, Annetta; Grant, Tim; Lucy, Frances E.; Mulcahy, Grace; De Waal, Theo
2015-01-01
While a large number of laboratory methods for the detection of Cryptosporidium oocysts in faecal samples are now available, their efficacy for identifying asymptomatic cases of cryptosporidiosis is poorly understood. This study was carried out to determine a reliable screening test for epidemiological studies in livestock. In addition, three molecular tests were compared to identify Cryptosporidium species responsible for the infection in cattle, sheep and horses. A variety of diagnostic tests including microscopic (Kinyoun's staining), immunological (Direct Fluorescence Antibody tests or DFAT), enzyme-linked immunosorbent assay (ELISA), and molecular methods (nested PCR) were compared to assess their ability to detect Cryptosporidium in cattle, horse and sheep faecal samples. The results indicate that the sensitivity and specificity of each test is highly dependent on the input samples; while Kinyoun's and DFAT proved to be reliable screening tools for cattle samples, DFAT and PCR analysis (targeted at the 18S rRNA gene fragment) were more sensitive for screening sheep and horse samples. Finally different PCR primer sets targeted at the same region resulted in the preferential amplification of certain Cryptosporidium species when multiple species were present in the sample. Therefore, for identification of Cryptosporidium spp. in the event of asymptomatic cryptosporidiosis, the combination of different 18S rRNA nested PCR primer sets is recommended for further epidemiological applications and also tracking the sources of infection. PMID:25662435
Benefits and Limitations of Prenatal Screening for Prader-Willi Syndrome
Butler, Merlin G.
2016-01-01
This review the status of genetic laboratory testing in Prader-Willi syndrome (PWS) due to different genetic subtypes, most often a paternally derived 15q11-q13 deletion, with benefits and limitations related to prenatal screening. Medical literature was searched for prenatal screening and genetic laboratory testing methods in use or under development and discussed in relationship to PWS. Genetic testing includes six established laboratory diagnostic approaches for PWS with direct application to prenatal screening. Ultrasonographic, obstetric and cytogenetic reports were summarized in relationship to the cause of Prader-Willi syndrome and identification of specific genetic subtypes including maternal disomy 15. Advances in genetic technology were described for diagnosing PWS specifically DNA methylation and high-resolution chromosomal SNP microarrays as current tools for genetic screening and incorporating next generation DNA sequencing for noninvasive prenatal testing (NIPT) using cell-free fetal DNA. Positive experiences are reported with NIPT for detection of numerical chromosomal problems (aneuploidies) but not for structural problems (microdeletions). These reports will be discussed along with future directions for genetic screening of PWS. In summary, this review describes and discusses the status of established and ongoing genetic testing options for PWS applicable in prenatal screening including NIPT and future directions for early diagnosis in Prader-Willi syndrome. PMID:27537837
Benefits and limitations of prenatal screening for Prader-Willi syndrome.
Butler, Merlin G
2017-01-01
This review summarizes the status of genetic laboratory testing in Prader-Willi syndrome (PWS) with different genetic subtypes, most often a paternally derived 15q11-q13 deletion and discusses benefits and limitations related to prenatal screening. Medical literature was searched for prenatal screening and genetic laboratory testing methods in use or under development and discussed in relationship to PWS. Genetic testing includes six established laboratory diagnostic approaches for PWS with direct application to prenatal screening. Ultrasonographic, obstetric and cytogenetic reports were summarized in relationship to the cause of PWS and identification of specific genetic subtypes including maternal disomy 15. Advances in genetic technology were described for diagnosing PWS specifically DNA methylation and high-resolution chromosomal SNP microarrays as current tools for genetic screening and incorporating next generation DNA sequencing for noninvasive prenatal testing (NIPT) using cell-free fetal DNA. Positive experiences are reported with NIPT for detection of numerical chromosomal problems (aneuploidies) but not for structural problems (microdeletions). These reports will be discussed along with future directions for genetic screening of PWS. In summary, this review describes and discusses the status of established and ongoing genetic testing options for PWS applicable in prenatal screening including NIPT and future directions for early diagnosis in PWS. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.
Who attends a UK diabetes screening programme? Findings from the ADDITION-Cambridge study.
Sargeant, L A; Simmons, R K; Barling, R S; Butler, R; Williams, K M; Prevost, A T; Kinmonth, A L; Wareham, N J; Griffin, S J
2010-09-01
One of the factors influencing the cost-effectiveness of population screening for Type 2 diabetes may be uptake. We examined attendance and practice- and individual-level factors influencing uptake at each stage of a diabetes screening programme in general practice. A stepwise screening programme was undertaken among 135, 825 people aged 40-69 years without known diabetes in 49 general practices in East England. The programme included a score based on routinely available data (age, sex, body mass index and prescribed medication) to identify those at high risk, who were offered random capillary blood glucose (RBG) and glycosylated haemoglobin tests. Those screening positive were offered fasting capillary blood glucose (FBG) and confirmatory oral glucose tolerance tests (OGTT). There were 33 539 high-risk individuals invited for a RBG screening test; 24 654 (74%) attended. Ninety-four per cent attended the follow-up FBG test and 82% the diagnostic OGTT. Seventy per cent of individuals completed the screening programme. Practices with higher general practitioner staff complements and those located in more deprived areas had lower uptake for RBG and FBG tests. Male sex and a higher body mass index were associated with lower attendance for RBG testing. Older age, prescription of antihypertensive medication and a higher risk score were associated with higher attendance for FBG and RBG tests. High attendance rates can be achieved by targeted stepwise screening of individuals assessed as high risk by data routinely available in general practice. Different strategies may be required to increase initial attendance, ensure completion of the screening programme, and reduce the risk that screening increases health inequalities.
Negeri, Zelalem F; Shaikh, Mateen; Beyene, Joseph
2018-05-11
Diagnostic or screening tests are widely used in medical fields to classify patients according to their disease status. Several statistical models for meta-analysis of diagnostic test accuracy studies have been developed to synthesize test sensitivity and specificity of a diagnostic test of interest. Because of the correlation between test sensitivity and specificity, modeling the two measures using a bivariate model is recommended. In this paper, we extend the current standard bivariate linear mixed model (LMM) by proposing two variance-stabilizing transformations: the arcsine square root and the Freeman-Tukey double arcsine transformation. We compared the performance of the proposed methods with the standard method through simulations using several performance measures. The simulation results showed that our proposed methods performed better than the standard LMM in terms of bias, root mean square error, and coverage probability in most of the scenarios, even when data were generated assuming the standard LMM. We also illustrated the methods using two real data sets. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The role of human papillomavirus in screening for cervical cancer.
McFadden, S E; Schumann, L
2001-03-01
To review the options for effectively screening for cervical cancer, including human papilloma virus (HPV) identification, cytologic screening, colposcopy, or a combination approach. Current pathophysiology, diagnostic criteria, treatment approaches, and patient preparation and education related to cervical cancer screening and prevention are also included. Comprehensive review of current literature, including research and review articles. Because the Papanicolau (Pap) smear is a screening tool, not a diagnostic tool, further studies must be done to identify the actual nature of discovered abnormalities. Of particular concern is the classification of atypical squamous cells of undetermined significance (ASCUS), which may simply indicate inflammation, or may be the first indicator of serious pathology. Following ASCUS Pap smears with HPV screening will allow for a clarification of the best approach to treatment. A screening algorithm supported by a review of the literature is proposed. Cervical cancer is a preventable disease caused by certain forms of HPV. Current screening protocols are based on the use of the Pap smear; and in areas where this test is routine and available, morbidity and mortality rates have dropped dramatically. Many women throughout the world and in underserved regions of the U. S. do not have adequate access to routine screening with Pap smear technology. As long as women continue to die needlessly of cervical cancer, more comprehensive and accessible screening methods must be explored. (Cutting the unnecessary worldwide and in the U. S.).
Proposed biopsy performance benchmarks for MRI based on an audit of a large academic center.
Sedora Román, Neda I; Mehta, Tejas S; Sharpe, Richard E; Slanetz, Priscilla J; Venkataraman, Shambhavi; Fein-Zachary, Valerie; Dialani, Vandana
2018-05-01
Performance benchmarks exist for mammography (MG); however, performance benchmarks for magnetic resonance imaging (MRI) are not yet fully developed. The purpose of our study was to perform an MRI audit based on established MG and screening MRI benchmarks and to review whether these benchmarks can be applied to an MRI practice. An IRB approved retrospective review of breast MRIs was performed at our center from 1/1/2011 through 12/31/13. For patients with biopsy recommendation, core biopsy and surgical pathology results were reviewed. The data were used to derive mean performance parameter values, including abnormal interpretation rate (AIR), positive predictive value (PPV), cancer detection rate (CDR), percentage of minimal cancers and axillary node negative cancers and compared with MG and screening MRI benchmarks. MRIs were also divided by screening and diagnostic indications to assess for differences in performance benchmarks amongst these two groups. Of the 2455 MRIs performed over 3-years, 1563 were performed for screening indications and 892 for diagnostic indications. With the exception of PPV2 for screening breast MRIs from 2011 to 2013, PPVs were met for our screening and diagnostic populations when compared to the MRI screening benchmarks established by the Breast Imaging Reporting and Data System (BI-RADS) 5 Atlas ® . AIR and CDR were lower for screening indications as compared to diagnostic indications. New MRI screening benchmarks can be used for screening MRI audits while the American College of Radiology (ACR) desirable goals for diagnostic MG can be used for diagnostic MRI audits. Our study corroborates established findings regarding differences in AIR and CDR amongst screening versus diagnostic indications. © 2017 Wiley Periodicals, Inc.
Zbroch, Tomasz; Knapp, Paweł Grzegorz; Knapp, Piotr Andrzej
2007-09-01
Increasing knowledge concerning carcinogenesis within cervical epithelium has forced us to make continues modifications of cytology classification of the cervical smears. Eventually, new descriptions of the submicroscopic cytomorphological abnormalities have enabled the implementation of Bethesda System which was meant to take place of the former Papanicolaou classification although temporarily both are sometimes used simultaneously. The aim of this study was to compare results of these two classification systems in the aspect of diagnostic accuracy verified by further tests of the diagnostic algorithm for the cervical lesion evaluation. The study was conducted in the group of women selected from general population, the criteria being the place of living and cervical cancer age risk group, in the consecutive periods of mass screening in Podlaski region. The performed diagnostic tests have been based on the commonly used algorithm, as well as identical laboratory and methodological conditions. Performed assessment revealed comparable diagnostic accuracy of both analyzing classifications, verified by histological examination, although with marked higher specificity for dysplastic lesions with decreased number of HSIL results and increased diagnosis of LSILs. Higher number of performed colposcopies and biopsies were an additional consequence of TBS classification. Results based on Bethesda System made it possible to find the sources and reasons of abnormalities with much greater precision, which enabled causing agent treatment. Two evaluated cytology classification systems, although not much different, depicted higher potential of TBS and better, more effective communication between cytology laboratory and gynecologist, making reasonable implementation of The Bethesda System in the daily cytology screening work.
Lumbiganon, Pisake; Chongsomchai, Chompilas; Chumworathayee, Bundit; Thinkhamrop, Jadsada
2002-08-01
The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.
Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.
Iskandar, Livia; Braun, Kathryn L; Katz, Alan R
2015-04-01
Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.
Pettit, K E; Hull, A D; Korty, L; Jones, M C; Pretorius, D H
2014-10-01
To characterize the patient population utilizing circulating cell-free fetal DNA (ccffDNA) testing at a large academic center and evaluate trends in the performance of invasive diagnostic procedures. A retrospective cohort study of all patients who underwent cell-free DNA testing from May to December 2012 was performed. During the study period, 206 patients had cell-free DNA testing. Of those, 75% (155/206) were of ages ⩾ 35 years. Of those undergoing ccffDNA testing, 41% had positive aneuploidy screening and 38% had abnormal ultrasound findings. Only 7% of the patients with negative ccffDNA testing opted for an invasive diagnostic procedure compared with 60% with positive testing (P<0.01). The rate of invasive procedures decreased from 5.9% of all visits to the center during a similar 8-month period in 2010 to 4.1% of all visits during the study period (P<0.01). Our data suggest that ccffDNA testing leads to reduced uptake of invasive procedures.
Singh, Manju; Singh, Shoor Vir; Gupta, Saurabh; Chaubey, Kundan Kumar; Stephan, Bjorn John; Sohal, Jagdip Singh; Dutta, Manali
2018-04-26
Early rapid detection of Mycobacterium avium subspecies paratuberculosis (MAP) bacilli in milk samples is the major challenge since traditional culture method is time consuming and laboratory dependent. We report a simple, sensitive and specific nano-technology based 'Nano-immuno test' capable of detecting viable MAP bacilli in the milk samples within 10 h. Viable MAP bacilli were captured by MAP specific antibody-conjugated magnetic nano-particles using resazurin dye as chromogen. Test was optimized using true culture positive (10-bovine and 12-goats) and true culture negative (16-bovine and 25-goats) raw milk samples. Domestic livestock species in India are endemically infected with MAP. After successful optimization, sensitivity and specificity of the 'nano-immuno test' in goats with respect to milk culture was 91.7% and 96.0%, respectively. Whereas, it was 90.0% (sensitivity) and 92.6% (specificity) with respect to IS900 PCR. In bovine milk samples, sensitivity and specificity of 'nano-immuno test' with respect to milk culture was 90.0% and 93.7%, respectively. However, with respect to IS900 PCR, the sensitivity and specificity was 88.9% and 94.1%, respectively. Test was validated with field raw milk samples (goats-258 and bovine-138) collected from domestic livestock species to detect live/viable MAP bacilli. Of 138 bovine raw milk samples screened by six diagnostic tests, 81 (58.7%) milk samples were positive for MAP infection in one or more than one diagnostic tests. Of 81 (58.7%) positive bovine raw milk samples, only 24 (17.4%) samples were detected positive for the presence of viable MAP bacilli. Of 258 goats raw milk samples screened by six diagnostic tests, 141 (54.6%) were positive for MAP infection in one or more than one test. Of 141 (54.6%) positive raw milk samples from goats, only 48 (34.0%) were detected positive for live MAP bacilli. Simplicity and efficiency of this novel 'nano-immuno test' makes it suitable for wide-scale screening of milk samples in the field. Standardization, validation and re-usability of functionalized nano-particles and the test was successfully achieved in field samples. Test was highly specific, simple to perform and easy to read by naked eyes and does not require laboratory support in the performance of test. Test has potential to be used as screening test to estimate bio-load of MAP in milk samples at National level.
Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique
2017-01-01
In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.
Glucose-6-phosphate dehydrogenase laboratory assay: How, when, and why?
Minucci, Angelo; Giardina, Bruno; Zuppi, Cecilia; Capoluongo, Ettore
2009-01-01
Glucose 6-phosphate dehydrogenase (G6PD) deficiency is the most common defect of red blood cells. Although some different laboratory techniques or methods are employed for the biochemical screening, a strict relationship between biochemists, clinicians, and molecular biologists is necessary for a definitive diagnosis. This article represents an overview on the current laboratory tests finalized to the screening or to the definitive diagnosis of G6PD-deficiency, underlying the problems regarding the biochemical and molecular identification of heterozygote females other than those regarding the standardization of the clinical and laboratory diagnostic procedures. Finally, this review is aimed to give a flow-chart for the complete diagnostic approach of G6PD-deficiency.
Backscatter from metal surfaces in diagnostic radiology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kodera, Y.; Schmidt, R.A.; Chan, H.P.
Backscatter from four commonly used metals (aluminum, lead, copper, and iron) was measured under diagnostic imaging conditions, using screen-film systems as detectors. The results indicate that for an 80-kV filtered beam and Par Speed/XRP system, backscatter increases as aluminum (Al) thickness increases until it reaches a plateau of approximately 12% at 50 mm Al. The amount of backscatter from any of these four metals increases as the tube voltage is raised from 60 to 115 kV. Measured backscatter depends strongly on the screens used, possibly due to their attenuation and energy response. Backscatter from aluminum was significantly greater than thatmore » from the other metals tested.« less
Raifu, Amidu O.; El-Zein, Mariam; Sangwa-Lugoma, Ghislain; Ramanakumar, Agnihotram; Walter, Stephen D.
2017-01-01
Background Visual inspection with acetic acid (VIA) and Lugol’s iodine (VILI) are used to screen women for cervical cancer in low-resource settings. Little is known about correlates of their diagnostic accuracy by healthcare provider. We examined determinants of VIA and VILI screening accuracy by examiner in a cross-sectional screening study of 1528 women aged 30 years or older in a suburb of Kinshasa, Democratic Republic of Congo. Methods We used a logistic regression model for sensitivity and specificity to estimate the diagnostic accuracy of VIA and VILI, independently performed by nurse and physician, as a function of sociodemographic and reproductive health characteristics. Results Nurses rated tests as positive more often than physicians (36.3% vs 30.2% for VIA, 26.2% vs 25.2% for VILI). Women’s age was the most important determinant of performance. It was inversely associated with sensitivity (nurse’s VIA: p<0.001, nurse’s VILI: p = 0.018, physician’s VIA: p = 0.005, physician’s VILI: p = 0.006) but positively associated with specificity (all four combinations: p<0.001). Increasing parity adversely affected sensitivity and specificity, but the effects on sensitivity were significant for nurses only. The screening performance of physician’s assessment was significantly better than the nurse’s (difference in sensitivity: VIA = 13%, VILI = 16%; difference in specificity: VIA = 6%, VILI = 1%). Conclusions Age and parity influence the performance of visual tests for cervical cancer screening. Proper training of local healthcare providers in the conduct of these tests should take into account these factors for improved performance of VIA and VILI in detecting cervical precancerous lesions among women in limited-resource settings. PMID:28107486
Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.
Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B
2015-02-01
A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.
Adherence to Standards for Reporting Diagnostic Accuracy in Emergency Medicine Research.
Gallo, Lucas; Hua, Nadia; Mercuri, Mathew; Silveira, Angela; Worster, Andrew
2017-08-01
Diagnostic tests are used frequently in the emergency department (ED) to guide clinical decision making and, hence, influence clinical outcomes. The Standards for Reporting of Diagnostic Accuracy (STARD) criteria were developed to ensure that diagnostic test studies are performed and reported to best inform clinical decision making in the ED. The objective was to determine the extent to which diagnostic studies published in emergency medicine journals adhered to STARD 2003 criteria. Diagnostic studies published in eight MEDLINE-listed, peer-reviewed, emergency medicine journals over a 5-year period were reviewed for compliance to STARD criteria. A total of 12,649 articles were screened and 114 studies were included in our study. Twenty percent of these were randomly selected for assessment using STARD 2003 criteria. Adherence to STARD 2003 reporting standards for each criteria ranged from 8.7% adherence (criteria-reporting adverse events from performing index test or reference standard) to 100% (multiple criteria). Just over half of STARD criteria are reported in more than 80% studies. As poorly reported studies may negatively impact their clinical usefulness, it is essential that studies of diagnostic test accuracy be performed and reported adequately. Future studies should assess whether studies have improved compliance with the STARD 2015 criteria amendment. © 2017 by the Society for Academic Emergency Medicine.
Digital tomosynthesis in breast cancer: A systematic review.
García-León, F J; Llanos-Méndez, A; Isabel-Gómez, R
2015-01-01
To estimate and compare the diagnostic validity of tomosynthesis and digital mammography for screening and diagnosing breast cancer. We systematically searched MedLine, EMBASE, and Web of Science for the terms breast cancer, screening, tomosynthesis, mammography, sensitivity, and specificity in publications in the period comprising June 2010 through February 2013. We included studies on diagnostic tests and systematic reviews. Two reviewers selected and evaluated the articles. We used QUADAS 2 to evaluate the risk of bias and the NICE criteria to determine the level of evidence. We compiled a narrative synthesis. Of the 151 original studies identified, we selected 11 that included a total of 2475 women. The overall quality was low, with a risk of bias and follow-up and limitations regarding the applicability of the results. The level of evidence was not greater than level II. The sensitivity of tomosynthesis ranged from 69% to 100% and the specificity ranged from 54% to 100%. The negative likelihood ratio was good, and this makes tomosynthesis useful as a test to confirm a diagnosis. One-view tomosynthesis was no better than two-view digital mammography, and the evidence for the superiority of two-view tomosynthesis was inconclusive. The results for the diagnostic validity of tomosynthesis in the diagnosis of breast cancer were inconclusive and there were no results for its use in screening. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Lippi, Giuseppe; Pasalic, Leonardo; Favaloro, Emmanuel J
2015-08-01
Although assessment of prior personal and familial bleeding history is an important aspect of the diagnosis of bleeding disorders, patients with mild inherited bleeding disorders are sometimes clinically asymptomatic until presented with a hemostatic challenge. However, bleeding may occur after incursion of trauma or surgery, so detection of these conditions reflects an important facet of clinical and laboratory practice. Mild bleeding disorders may be detected as a result of family studies or following identification of abnormal values in first-line screening tests such as activated partial thromboplastin time, prothrombin time, fibrinogen and global platelet function screen testing, such as the platelet function analyzer. Following determination of abnormal screening tests, subsequent investigation should follow a systematic approach that targets specific diagnostic tests, and including factor assays, full platelet function assays and more extensive specialized hemostasis testing. The current report provides a personal overview on inherited disorders of blood coagulation and their detection.
Lees, Rosalind; Stott, David J; Quinn, Terence J; Broomfield, Niall M
2014-01-01
Depression/anxiety disorders are common after stroke and have a negative impact on outcomes. Guidelines recommend that all stroke survivors are screened for these problems. However, there is no consensus on timing or method of assessment. We investigated the feasibility and accuracy of a very early screening strategy and the diagnostic accuracy this has for depression/anxiety disorders at 1 month. Screening tools were Hospital Anxiety and Depression Scale (HADS) and Depression Intensity Scale Circles (DISCs); we also assessed cognition using the Montreal Cognitive Assessment (MoCA). Screening was offered to sequential stroke admissions. At 1 month we assessed for clinical depression/anxiety disorder using Mini-International Neuropsychiatric Interview (MINI) and retested screening tools. We described test accuracy of acute depression/anxiety screening for clinical diagnosis of depression/anxiety disorder at 1 month and described temporal change in screening test scores. We assessed feasibility by describing proportions that were able, agreed to and completed the screening tests. Over 4 months, 102/146 admissions were suitable for screening following initial medical assessment, 69 (68%) agreed to screening, of whom 33 (48%) required researcher assistance to complete the screening test battery. Median time to assessment was 2 days (IQR: 1-4). Early HADS suggested n = 9 (13%) with depression; DISCs n = 25 (37%). Median acute MoCA was 21/30. At 1 month, n = 61 (88%) provided data. Repeat scores showed improvement over time; HADS (anxiety) mean difference: 2.5 (95% CI: 1.2-3.7), HADS (depression) mean difference: 1.6 (95% CI: 0.3-2.9). MINI defined n = 12 (20%) with depression and n = 6 (10%) with anxiety disorder. Comparing baseline screening to 1-month clinical diagnosis, HADS sensitivity was 0.25 (95% CI: 0.09-0.53) and specificity 0.94 (95% CI: 0.84-0.98); DISCs sensitivity was 0.92 (95% CI: 0.65-0.99) and specificity 0.78 (95% CI: 0.64-0.87). Even amongst 'medically stable' stroke patients, depression/anxiety screening at the acute stage may not be feasible or accurate. Half of participants required assistance from the researcher to complete assessments. The poor predictive accuracy of HADS for depression/anxiety disorder at 1 month may be due in part to the high prevalence of cognitive impairment in our sample. Screening in the first few days after stroke does not appear useful for detecting clinically important and sustained depression/anxiety problems. © 2014 S. Karger AG, Basel.
Kesli, Recep; Polat, Hakki; Terzi, Yuksel; Kurtoglu, Muhammet Guzel; Uyar, Yavuz
2011-12-01
Hepatitis C virus (HCV) is a global health care problem. Diagnosis of HCV infection is mainly based on the detection of anti-HCV antibodies as a screening test with serum samples. Recombinant immunoblot assays are used as supplemental tests and for the final detection and quantification of HCV RNA in confirmatory tests. In this study, we aimed to compare the HCV core antigen test with the HCV RNA assay for confirming anti-HCV results to determine whether the HCV core antigen test may be used as an alternative confirmatory test to the HCV RNA test and to assess the diagnostic values of the total HCV core antigen test by determining the diagnostic specificity and sensitivity rates compared with the HCV RNA test. Sera from a total of 212 treatment-naive patients were analyzed for anti-HCV and HCV core antigen both with the Abbott Architect test and with the molecular HCV RNA assay consisting of a reverse transcription-PCR method as a confirmatory test. The diagnostic sensitivity, specificity, and positive and negative predictive values of the HCV core antigen assay compared to the HCV RNA test were 96.3%, 100%, 100%, and 89.7%, respectively. The levels of HCV core antigen showed a good correlation with those from the HCV RNA quantification (r = 0.907). In conclusion, the Architect HCV antigen assay is highly specific, sensitive, reliable, easy to perform, reproducible, cost-effective, and applicable as a screening, supplemental, and preconfirmatory test for anti-HCV assays used in laboratory procedures for the diagnosis of hepatitis C virus infection.
Bryant, Louise D; Green, Josephine M; Hewison, Jenny
2010-12-01
Research considering the role of attitudes in prenatal testing choices has commonly focused on the relationship between the attitude towards undergoing testing and actual testing behaviour. In contrast, this study focused on the relationship between testing behaviour and attitudes towards the targets of the behaviour (in this case people with Down syndrome (DS) and having a baby with DS). A cross-sectional, prospective survey of 197 pregnant women measured attitudes towards the targets of prenatal testing along with intentions to use screening and diagnostic testing, and the termination of an affected pregnancy. Screening uptake was established via patient records. Although attitudes towards DS and having a baby with DS were significantly associated with screening uptake and testing and termination intentions, unfavourable attitudes were better than favourable ones at predicting these outcomes. For example, in the quartile of women with the 'most favourable' attitude towards people with DS 67% used screening although only 8% said they would terminate an affected pregnancy. Qualitative data suggested that not all women considered personal attitudes towards DS to be relevant to their screening decisions. This finding has implications for the way in which informed choice is currently understood and measured in the prenatal testing context.
Clinical potential of proteomics in the diagnosis of ovarian cancer.
Ardekani, Ali M; Liotta, Lance A; Petricoin, Emanuel F
2002-07-01
The need for specific and sensitive markers of ovarian cancer is critical. Finding a sensitive and specific test for its detection has an important public health impact. Currently, there are no effective screening options available for patients with ovarian cancer. CA-125, the most widely used biomarker for ovarian cancer, does not have a high positive predictive value and it is only effective when used in combination with other diagnostic tests. However, pathologic changes taking place within the ovary may be reflected in biomarker patterns in the serum. Combination of mass spectra generated by new proteomic technologies, such as surface-enhanced laser desorption ionization time-of-flight (SELDI-TOF) and artificial-intelligence-based informatic algorithms, have been used to discover a small set of key protein values and discriminate normal from ovarian cancer patients. Serum proteomic pattern analysis might be applied ultimately in medical screening clinics, as a supplement to the diagnostic work-up and evaluation.
High-speed spectral nanocytology for early cancer screening
Subramanian, Hariharan; Maneval, Charles D.; White, Craig A.; Levenson, Richard M.; Backman, Vadim
2013-01-01
Abstract. High-throughput partial wave spectroscopy (HTPWS) is introduced as a high-speed spectral nanocytology technique that utilizes the field effect of carcinogenesis to perform minimally invasive cancer screening on at-risk populations. HTPWS uses fully automated hardware and an acousto-optic tunable filter to scan slides at low magnification, to select cells, and to rapidly acquire spectra at each spatial pixel in a cell between 450 and 700 nm, completing measurements of 30 cells in 40 min. Statistical quantitative analysis on the size and density of intracellular nanostructures extracted from the spectra at each pixel in a cell yields the diagnostic biomarker, disorder strength (Ld). Linear correlation between Ld and the length scale of nanostructures was measured in phantoms with R2=0.93. Diagnostic sensitivity was demonstrated by measuring significantly higher Ld from a human colon cancer cell line (HT29 control vector) than a less aggressive variant (epidermal growth factor receptor knockdown). Clinical diagnostic performance for lung cancer screening was tested on 23 patients, yielding a significant difference in Ld between smokers and cancer patients, p=0.02 and effect size=1.00. The high-throughput performance, nanoscale sensitivity, and diagnostic sensitivity make HTPWS a potentially clinically relevant modality for risk stratification of the large populations at risk of developing cancer. PMID:24193949
Computational diagnosis of canine lymphoma
NASA Astrophysics Data System (ADS)
Mirkes, E. M.; Alexandrakis, I.; Slater, K.; Tuli, R.; Gorban, A. N.
2014-03-01
One out of four dogs will develop cancer in their lifetime and 20% of those will be lymphoma cases. PetScreen developed a lymphoma blood test using serum samples collected from several veterinary practices. The samples were fractionated and analysed by mass spectrometry. Two protein peaks, with the highest diagnostic power, were selected and further identified as acute phase proteins, C-Reactive Protein and Haptoglobin. Data mining methods were then applied to the collected data for the development of an online computer-assisted veterinary diagnostic tool. The generated software can be used as a diagnostic, monitoring and screening tool. Initially, the diagnosis of lymphoma was formulated as a classification problem and then later refined as a lymphoma risk estimation. Three methods, decision trees, kNN and probability density evaluation, were used for classification and risk estimation and several preprocessing approaches were implemented to create the diagnostic system. For the differential diagnosis the best solution gave a sensitivity and specificity of 83.5% and 77%, respectively (using three input features, CRP, Haptoglobin and standard clinical symptom). For the screening task, the decision tree method provided the best result, with sensitivity and specificity of 81.4% and >99%, respectively (using the same input features). Furthermore, the development and application of new techniques for the generation of risk maps allowed their user-friendly visualization.
A Research Agenda for Malaria Eradication: Diagnoses and Diagnostics
2011-01-01
Many of malaria's signs and symptoms are indistinguishable from those of other febrile diseases. Detection of the presence of Plasmodium parasites is essential, therefore, to guide case management. Improved diagnostic tools are required to enable targeted treatment of infected individuals. In addition, field-ready diagnostic tools for mass screening and surveillance that can detect asymptomatic infections of very low parasite densities are needed to monitor transmission reduction and ensure elimination. Antibody-based tests for infection and novel methods based on biomarkers need further development and validation, as do methods for the detection and treatment of Plasmodium vivax. Current rapid diagnostic tests targeting P. vivax are generally less effective than those targeting Plasmodium falciparum. Moreover, because current drugs for radical cure may cause serious side effects in patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency, more information is needed on the distribution of G6PD-deficiency variants as well as tests to identify at-risk individuals. Finally, in an environment of very low or absent malaria transmission, sustaining interest in elimination and maintaining resources will become increasingly important. Thus, research is required into the context in which malaria diagnostic tests are used, into diagnostics for other febrile diseases, and into the integration of these tests into health systems. PMID:21311583
Current issues in diagnostic breast pathology.
Walker, Rosemary A; Hanby, Andy; Pinder, Sarah E; Thomas, Jeremy; Ellis, Ian O
2012-09-01
On behalf of the NHS Breast Screening Programme Pathology Coordinating Group we present recommendations for terminology and diagnostic criteria for a number of key areas of practice in breast pathology where terminology can be confusing and where accurate communication will ensure appropriate clinical management. These recommendations cover columnar cell lesions and the spectrum of changes that can be seen in these epithelial proliferations, lobular neoplasia, micrometastases and isolated tumour cells in axillary lymph nodes, the use of basal/myoepithelial markers in diagnostic practice and oestrogen receptor testing in ductal carcinoma in situ.
Prenatal diagnostic decision-making in adolescents.
Plaga, Stacey L; Demarco, Kristin; Shulman, Lee P
2005-04-01
We sought to evaluate the prenatal decision-making of pregnant adolescents identified at increased risk for identifiable fetal genetic abnormalities. A retrospective review of records of gravid women 19 years old or younger undergoing genetic counseling from 2001-2003 (inclusive) was undertaken. Hospital-based academic center. Thirty-seven women were identified; four cases did not meet inclusion criteria. None. Decision to undergo or forgo invasive prenatal testing. Of the 33 women included in this study, the average age was 17.6 years (range: 15-19). Eighteen were Latinas, eight were African-Americans, and seven were Caucasians. Sixteen women had positive maternal serum screening outcomes; nine women sought counseling because of personal/family histories of genetic abnormalities, seven sought counseling after fetal structural anomalies were detected by ultrasound, and one woman sought counseling because she and her partner were positive for Mendelian disorder screening (sickle cell disease). Sixteen of the women (48.5%) chose to undergo invasive testing (15 amniocenteses, one chorionic villus sampling) whereas 17 (51.5%) chose to forgo invasive testing. Adolescents offered invasive prenatal diagnosis will chose to undergo or forgo such testing based on diagnostic and personal criteria as do adult women. Nonetheless, unique adolescent issues may make the process by which information is obtained and communicated during counseling to be different from counseling provided to adults. The development of new genetic screening and diagnostic protocols has and will increase the number of pregnant adolescent women who will be offered genetic counseling during their pregnancies. Such an increase in numbers will place considerably more pressure on an already taxed genetic counseling system; accordingly, new counseling paradigms will need to be developed to provide service to an expanded patient population seeking information for an increasing number of genetic issues.
Clinical Utility of Urinary Cytology to Detect BK Viral Nephropathy.
Nankivell, Brian J; Renthawa, Jasveen; Jeoffreys, Neisha; Kable, Kathy; O'Connell, Philip J; Chapman, Jeremy R; Wong, Germaine; Sharma, Raghwa N
2015-08-01
Reactivation of BK polyoma virus can result in destructive viral allograft nephropathy (BKVAN) with limited treatment options. Screening programs using surrogate markers of viral replication are important preventive strategies, guiding immunosuppression reduction. We prospectively evaluated the diagnostic test performance of urinary decoy cells and urinary SV40T immunochemistry of exfoliated cells, to screen for BKVAN, (defined by reference histology with SV40 immunohistochemistry, n = 704 samples), compared with quantitative viremia, from 211 kidney and 141 kidney-pancreas transplant recipients. The disease prevalence of BKVAN was 2.6%. Decoy cells occurred in 95 of 704 (13.5%) samples, with a sensitivity of 66.7%, specificity of 88.6%, positive predictive value (PPV) of 11.7%, and negative predictive value of 98.5% to predict histologically proven BKVAN. Quantification of decoy cells improved the PPV to 32.1% (10 ≥ cells threshold). Immunohistochemical staining of urinary exfoliated cells for SV40T improved sensitivity to 85.7%, detecting atypical or degenerate infected cells (specificity of 92.3% and PPV of 33.3%), but was hampered by technical failures. Viremia occurred in 90 of 704 (12.8%) with sensitivity of 96.3%, specificity of 90.3%, PPV of 31.5%, and negative predictive value of 99.8%. The receiver-operator curve performance of quantitative viremia surpassed decoy cells (area under the curve of 0.95 and 0.79, respectively, P = 0.0018 for differences). Combining decoy cell and BK viremia in a diagnostic matrix improved prediction of BKVAN and diagnostic risk stratification, especially for high-level positive results. Although quantified decoy cells are acceptable surrogate markers of BK viral replication with unexceptional test performances, quantitative viremia displayed superior test characteristics and is suggested as the screening test of choice.
Gajjar, Ketan; Ahmadzai, Abdullah A.; Valasoulis, George; Trevisan, Júlio; Founta, Christina; Nasioutziki, Maria; Loufopoulos, Aristotelis; Kyrgiou, Maria; Stasinou, Sofia Melina; Karakitsos, Petros; Paraskevaidis, Evangelos; Da Gama-Rose, Bianca; Martin-Hirsch, Pierre L.; Martin, Francis L.
2014-01-01
Background Subjective visual assessment of cervical cytology is flawed, and this can manifest itself by inter- and intra-observer variability resulting ultimately in the degree of discordance in the grading categorisation of samples in screening vs. representative histology. Biospectroscopy methods have been suggested as sensor-based tools that can deliver objective assessments of cytology. However, studies to date have been apparently flawed by a corresponding lack of diagnostic efficiency when samples have previously been classed using cytology screening. This raises the question as to whether categorisation of cervical cytology based on imperfect conventional screening reduces the diagnostic accuracy of biospectroscopy approaches; are these latter methods more accurate and diagnose underlying disease? The purpose of this study was to compare the objective accuracy of infrared (IR) spectroscopy of cervical cytology samples using conventional cytology vs. histology-based categorisation. Methods Within a typical clinical setting, a total of n = 322 liquid-based cytology samples were collected immediately before biopsy. Of these, it was possible to acquire subsequent histology for n = 154. Cytology samples were categorised according to conventional screening methods and subsequently interrogated employing attenuated total reflection Fourier-transform IR (ATR-FTIR) spectroscopy. IR spectra were pre-processed and analysed using linear discriminant analysis. Dunn’s test was applied to identify the differences in spectra. Within the diagnostic categories, histology allowed us to determine the comparative efficiency of conventional screening vs. biospectroscopy to correctly identify either true atypia or underlying disease. Results Conventional cytology-based screening results in poor sensitivity and specificity. IR spectra derived from cervical cytology do not appear to discriminate in a diagnostic fashion when categories were based on conventional screening. Scores plots of IR spectra exhibit marked crossover of spectral points between different cytological categories. Although, significant differences between spectral bands in different categories are noted, crossover samples point to the potential for poor specificity and hampers the development of biospectroscopy as a diagnostic tool. However, when histology-based categories are used to conduct analyses, the scores plot of IR spectra exhibit markedly better segregation. Conclusions Histology demonstrates that ATR-FTIR spectroscopy of liquid-based cytology identifies the presence of underlying atypia or disease missed in conventional cytology screening. This study points to an urgent need for a future biospectroscopy study where categories are based on such histology. It will allow for the validation of this approach as a screening tool. PMID:24404130
Use of Preschool Preposition Test for Mentally Retarded and Other Handicapped Children.
ERIC Educational Resources Information Center
Aaronson, May; And Others
The usefulness of the Preschool Preposition Test (PPT) as a cognitive screening and diagnostic tool for handicapped children is demonstrated through results of eight independent studies. The subjects were 354 children and youths, aged two to 20 years, with various handicaps: mentally retarded, autistic-like, moderately emotionally disturbed,…
Lundman, Emma; Gaup, H Junita; Bakkeheim, Egil; Olafsdottir, Edda J; Rootwelt, Terje; Storrøsten, Olav Trond; Pettersen, Rolf D
2016-05-01
Norway introduced newborn screening for cystic fibrosis (CF) March 1, 2012. We present results from the first three years of the national newborn CF screening program. Positive primary screening of immunoreactive trypsinogen (IRT) was followed by DNA testing of the Cystic fibrosis transmembrane conductance regulator (CFTR) gene. Infants with two CFTR mutations were reported for diagnostic follow-up. Of 181,859 infants tested, 1454 samples (0.80%) were assessed for CFTR mutations. Forty children (1:4546) had two CFTR mutations, of which only 21 (1:8660) were confirmed to have a CF diagnosis. The CFTR mutations differed from previously clinically diagnosed CF patients, and p.R117H outnumbered p.F508del as the most frequent mutation. One child with a negative IRT screening test was later clinically diagnosed with CF. The CF screening program identified fewer children with a conclusive CF diagnosis than expected. Our data suggest a revision of the IRT/DNA protocol. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Baker, Cristina A; Thomas, William; Stauffer, William M; Peterson, Phillip K; Tsukayama, Dean T
2009-04-01
Screening for latent tuberculosis infection (LTBI) in refugee populations immigrating to low-incidence countries remains a challenge. We assessed the characteristics of the QuantiFERON-Gold In-Tube (QFT-GIT) compared with the tuberculin skin test (TST) in 198 refugees of all ages from tuberculosis-endemic countries. Diagnostic agreement between the first QFT-GIT and simultaneous TST was 78% (kappa = 0.56) and between serial QFT-GITs was 89% (kappa = 0.76). In serial QFT-GIT testing, 70% of subjects had an increased QFT-GIT value, perhaps the result of an antecedent TST in the setting of previous TB exposure. This boosting seemed to become less prevalent with time from TST and occurred less frequently in those with negative first QFT-GIT readings. Despite small changes in the quantitative results caused by nonspecific variation and boosting, the diagnostic result of the QFT-GIT was reliable. The QFT-GIT shows the potential to replace the TST for LTBI screening in refugees from tuberculosis-endemic areas.
Clark, Cheryl R; Tosteson, Tor D; Tosteson, Anna N A; Onega, Tracy; Weiss, Julie E; Harris, Kimberly A; Haas, Jennifer S
2017-05-01
Digital breast tomosynthesis (DBT) has shown potential to improve breast cancer screening and diagnosis compared to digital mammography (DM). The FDA approved DBT use in conjunction with conventional DM in 2011, but coverage was approved by CMS recently in 2015. Given changes in coverage policies, it is important to monitor diffusion of DBT by insurance type. This study examined DBT trends and estimated associations with insurance type. From June 2011 to September 2014, DBT use in 22 primary care centers in the Dartmouth -Brigham and Women's Hospital Population-based Research Optimizing Screening through Personalized Regimens research center (PROSPR) was examined among women aged 40-89. A longitudinal repeated measures analysis estimated the proportion of DBT performed for screening or diagnostic indications over time and by insurance type. During the study period, 93,182 mammograms were performed on 48,234 women. Of these exams, 16,506 DBT tests were performed for screening (18.1%) and 2537 were performed for diagnosis (15.7%). Between 2011 and 2014, DBT utilization increased in all insurance groups. However, by the latest observed period, screening DBT was used more frequently under private insurance (43.4%) than Medicaid (36.2%), Medicare (37.8%), other (38.6%), or no insurance (32.9%; P < 0.0001). No sustained differences in use of DBT for diagnostic testing were seen by insurance type. DBT is increasingly used for breast cancer screening and diagnosis. Use of screening DBT may be associated with insurance type. Surveillance is required to ensure that disparities in breast cancer screening are minimized as DBT becomes more widely available. © 2017 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.
The diagnostic accuracy of exercise electrocardiography - A review
NASA Technical Reports Server (NTRS)
Johnson, R. L.; Bungo, M. W.
1983-01-01
The cardiovascular 'stress test', and particularly the graded treadmill exercist test, has gained wide acceptance as a diagnostic aid in searching for ischemic heart disease and as a prognostic indicator for those with known coronary artery disease. Controversies still exist, however, in its use in mass screening and in interpreting equivocal tests. A review of the use and value of electrocardiographic exercise testing is presented. Topics such as its use in asymptomatic individuals, the adjuvant use of clinical examination, and the examination of ancillary treadmill parameters are presented. No attempt is made to detail the very significant contributions of radionuclide scanning. The positive exercise electrocardiogram in the asymptomatic subject is discussed and guidelines for clinical management are offered.
Slavkin, H C; Fox, C H; Meyer, D M
2011-10-01
Oral fluid-based (salivary) tests have the potential to create practical, point-of-care clinical instruments that are convenient, practical, and comfortable to use in dentistry and medicine. Currently, there are no simple, accurate, and inexpensive sampling, screening, or detection methods to support definitive diagnostic platforms across dental and medical disciplines. Though the benefits from advancing screening and detection technologies seem eminent, analytical, chemical, molecular, genetic, and protein markers are still under development. Clinical applications in patient care must be validated independently to ensure that they are clinically accurate, reliable, precise, and uniformly consistent for screening and detecting specific diseases or conditions. As technology designed to improve patient care through risk assessment, prevention, and disease management is transferred into clinical practice, dentistry may need to reassess its role in general health care. © International & American Associations for Dental Research
Role of Investigating Thrombophilic Disorders in Young Stroke
Ng, Kay W. P.; Loh, Pei K.; Sharma, Vijay K.
2011-01-01
Our knowledge about various inherited and acquired causes of thrombophilic disorders has increased significantly during the past decade. Technology for various diagnostic tests for these rare disorders has matched the rapid advances in our understanding about the thrombophilic disorders. Inherited thrombophilic disorders predispose young patients for various venous or arterial thrombotic and thromboembolic episodes. Our understanding has also improved about various gene-gene and gene-environment interactions and their impact on the resultant heterogenous clinical manifestations. We describe various thrombophilic disorders, their diagnostic tests, pathogenic potential in isolation or with other concurrent inherited/acquired defects and possible therapeutic and prophylactic strategies. Better understanding, optimal diagnostic and screening protocols are expected to improve the diagnostic yield and help to reduce morbidity, disability, and mortality in relatively younger patients harbouring these inherited and acquired thrombophilic disorders. PMID:21331344
Moreno, Courtney C; Mittal, Pardeep K; Sullivan, Patrick S; Rutherford, Robin; Staley, Charles A; Cardona, Kenneth; Hawk, Natalyn N; Dixon, W Thomas; Kitajima, Hiroumi D; Kang, Jian; Small, William C; Oshinski, John; Votaw, John R
2016-03-01
Rates of colorectal cancer screening are improving but remain suboptimal. Limited information is available regarding how patients are diagnosed with colorectal cancer (for example, asymptomatic screened patients or diagnostic workup because of the presence of symptoms). The purpose of this investigation was to determine how patients were diagnosed with colorectal cancer (screening colonoscopy, diagnostic colonoscopy, or emergent surgery) and tumor stage and size at diagnosis. Adults evaluated between 2011 and 2014 with a diagnosis of colorectal cancer were identified. Clinical notes, endoscopy reports, surgical reports, radiology reports, and pathology reports were reviewed. Sex, race, ethnicity, age at the time of initial diagnosis, method of diagnosis, presenting symptom(s), and primary tumor size and stage at diagnosis were recorded. Colorectal cancer screening history was also recorded. The study population was 54% male (265 of 492) with a mean age of 58.9 years (range, 25-93 years). Initial tissue diagnosis was established at the time of screening colonoscopy in 10.7%, diagnostic colonoscopy in 79.2%, and during emergent surgery in 7.1%. Cancers diagnosed at the time of screening colonoscopy were more likely to be stage 1 than cancers diagnosed at the time of diagnostic colonoscopy or emergent surgery (38.5%, 7.2%, and 0%, respectively). Median tumor size was 3.0 cm for the screening colonoscopy group, 4.6 cm for the diagnostic colonoscopy group, and 5.0 cm for the emergent surgery group. At least 31% of patients diagnosed at the time of screening colonoscopy, 19% of patients diagnosed at the time of diagnostic colonoscopy, and 26% of patients diagnosed at the time of emergent surgery had never undergone a screening colonoscopy. Nearly 90% of colorectal cancer patients were diagnosed after development of symptoms and had more advanced disease than asymptomatic screening patients. Colorectal cancer outcomes will be improved by improving rates of colorectal cancer screening. Copyright © 2016 Elsevier Inc. All rights reserved.
Diagnostic methods for platelet bacteria screening: current status and developments.
Störmer, Melanie; Vollmer, Tanja
2014-02-01
Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes.
Green, Beverly B; Wang, C Y; Horner, Kathryn; Catz, Sheryl; Meenan, Richard T; Vernon, Sally W; Carrell, David; Chubak, Jessica; Ko, Cynthia; Laing, Sharon; Bogart, Andy
2010-11-01
Screening decreases colorectal cancer (CRC) morbidity and mortality, yet remains underutilized. Screening breakdowns arise from lack of uptake and failure to follow-up after a positive screening test. Systems of support to increase colorectal cancer screening and follow-up (SOS) is a randomized trial designed to increase: (1) CRC screening and (2) follow-up of positive screening tests. The Chronic Care Model and the Preventive Health Model inform study design. The setting is a large nonprofit healthcare organization. In part-1 study, patients age 50-75 due for CRC screening are randomized to one of 4 study conditions. Arm 1 receives usual care. Arm 2 receives automated support (mailed information about screening choices and fecal occult blood tests (FOBT)). Arm 3 receives automated and assisted support (a medical assistant telephone call). Arm 4 receives automated, assisted, and care management support (a registered nurse provides behavioral activation and coordination of care). In part-2, study patients with a positive FOBT or adenomas on flexible sigmoidoscopy are randomized to receive either usual care or nurse care management. Primary outcomes are: 1) the proportion with CRC screening, 2) the proportion with a complete diagnostic evaluation after a positive screening test. We sent recruitment letters to 15,414 patients and 4675 were randomized. Randomly assigned treatment groups were similar in age, sex, race, education, self-reported health, and CRC screening history. We will determine the effectiveness and cost effectiveness of stepped increases in systems of support to increase CRC screening and follow-up after a positive screening test over 2years. Copyright © 2010 Elsevier Inc. All rights reserved.
Kim, Hyuncheol Bryant; Lee, Sun-Mi
2017-05-01
This study investigates the impact of and behavioral responses to cost sharing in Korea's National Cancer Screening Program, which provides free stomach and breast cancer screenings to those with an income below a certain cutoff. Free cancer screening substantially increases the screening take up rate, yielding more cancer detections. However, the increase in cancer detection is quickly crowded out by cancer detection through other channels such as diagnostic testing and private cancer screening. Further, compliers are much less likely to have cancer than never takers. Crowd-out and selection help explain why the program has been unable to reduce cancer mortality. Copyright © 2017 Elsevier B.V. All rights reserved.
First-trimester screening for chromosomal abnormalities: advantages of an instant results approach.
Norton, Mary E
2010-09-01
Protocols that include first trimester screening for fetal chromosome abnormalities have become standard of care throughout the United States. Earlier screening allows for first trimester diagnostic testing in cases found to be at increased risk. However, first trimester screening requires coordination of the nuchal translucency ultrasound screening (NT) and biochemical screening, during early, specific, narrow, but slightly different gestational age ranges. Instant results can often be provided at the time of the NT ultrasound if preceded by the programs that perform the biochemical analyses; this optimizes the benefits of the first trimester approach while improving efficiency and communication with the patient. This article discusses the benefits and logistics of such an approach. Copyright 2010 Elsevier Inc. All rights reserved.
2014-01-01
Background Active, population-wide mass screening and treatment (MSAT) for chronic Plasmodium falciparum carriage to eliminate infectious reservoirs of malaria transmission have proven difficult to apply on large national scales through trained clinicians from central health authorities. Methodology Fourteen population clusters of approximately 1,000 residents centred around health facilities (HF) in two rural Zambian districts were each provided with three modestly remunerated community health workers (CHWs) conducting active monthly household visits to screen and treat all consenting residents for malaria infection with rapid diagnostic tests (RDT). Both CHWs and HFs also conducted passive case detection among residents who self-reported for screening and treatment. Results Diagnostic positivity was higher among symptomatic patients self-reporting to CHWs (42.5%) and HFs (24%) than actively screened residents (20.3%), but spatial and temporal variations of diagnostic positivity were highly consistent across all three systems. However, most malaria infections (55.6%) were identified through active home visits by CHWs rather than self-reporting to CHWs or HFs. Most (62%) malaria infections detected actively by CHWs reported one or more symptoms of illness. Most reports of fever and vomiting, plus more than a quarter of history of fever, headache and diarrhoea, were attributable to malaria infection. The minority of residents who participated >12 times had lower rates of malaria infection and associated symptoms in later contacts but most residents were tested <4 times and high malaria diagnostic positivity (32%) in active surveys, as well as incidence (1.7 detected infections per person per year) persisted in the population. Per capita cost for active service delivery by CHWs was US$5.14 but this would rise to US$10.68 with full community compliance with monthly testing at current levels of transmission, and US$6.25 if pre-elimination transmission levels and negligible treatment costs were achieved. Conclusion Monthly active home visits by CHWs equipped with RDTs were insufficient to eliminate the human infection reservoir in this typical African setting, despite reasonably high LLIN/IRS coverage. However, dramatic impact upon infection and morbidity burden might be attainable and cost-effective if community participation in regular testing could be improved and the substantial, but not necessarily prohibitive, costs are affordable to national programmes. PMID:24678631
Manirakiza, Alexandre; Serdouma, Eugène; Heredeïbona, Luc Salva; Djalle, Djibrine; Madji, Nestor; Moyen, Methode; Soula, Georges; Le Faou, Alain; Delmont, Jean
2012-06-26
Both treatment and prevention strategies are recommended by the World Health Organization for the control of malaria during pregnancy in tropical areas. The aim of this study was to assess use of a rapid diagnostic test for prompt management of malaria in pregnancy in Bangui, Central African Republic. A cohort of 76 pregnant women was screened systematically for malaria with ParacheckPf® at each antenatal visit. The usefulness of the method was analysed by comparing the number of malaria episodes requiring treatment in the cohort with the number of prescriptions received by another group of pregnant women followed-up in routine antenatal care. In the cohort group, the proportion of positive ParacheckPf® episodes during antenatal clinics visits was 13.8%, while episodes of antimalarial prescriptions in the group which was followed-up routinely by antenatal personnel was estimated at 26.3%. Hence, the relative risk of the cohort for being prescribed an antimalarial drug was 0.53. Therefore, the attributable fraction of presumptive treatment avoided by systematic screening with ParacheckPf® was 47%. Use of a rapid diagnostic test is useful, affordable and easy for adequate treatment of malaria in pregnant women. More powerful studies of the usefulness of introducing the test into antenatal care are needed in all heath centres in the country and in other tropical areas.
Lawn, Stephen D; Kerkhoff, Andrew D; Burton, Rosie; Schutz, Charlotte; van Wyk, Gavin; Vogt, Monica; Pahlana, Pearl; Nicol, Mark P; Meintjes, Graeme
2015-08-14
Autopsy studies of HIV/AIDS-related hospital deaths in sub-Saharan Africa reveal frequent failure of pre-mortem diagnosis of tuberculosis (TB), which is found in 34-64 % of adult cadavers. We determined the overall prevalence and predictors of TB among consecutive unselected HIV-positive adults requiring acute hospital admission and the comparative diagnostic yield obtained by screening urine and sputum samples obtained on day 1 of admission with Xpert MTB/RIF (Xpert). To determine overall TB prevalence accurately, comprehensive clinical sampling (sputum, urine, blood plus other relevant samples) was done and TB was defined by detection of Mycobacterium tuberculosis in any sample using Xpert and/or mycobacterial liquid culture. To evaluate a rapid screening strategy, we compared the diagnostic yield of Xpert testing sputum samples and urine samples obtained with assistance from a respiratory study nurse in the first 24 h of admission. Unselected HIV-positive acute adult new medical admissions (n = 427) who were not receiving TB treatment were enrolled irrespective of clinical presentation or symptom profile. From 2,391 cultures and Xpert tests done (mean, 5.6 tests/patient) on 1,745 samples (mean, 4.1 samples/patient), TB was diagnosed in 139 patients (median CD4 cell count, 80 cells/μL). TB prevalence was very high (32.6 %; 95 % CI, 28.1-37.2 %; 139/427). However, patient symptoms and risk factors were poorly predictive for TB. Overall, ≥1 non-respiratory sample(s) tested positive in 115/139 (83 %) of all TB cases, including positive blood cultures in 41/139 (29.5 %) of TB cases. In the first 24 h of admission, sputum (spot and/or induced samples) and urine were obtainable from 37.0 % and 99.5 % of patients, respectively (P <0.001). From these, the proportions of total TB cases (n = 139) that were diagnosed by Xpert testing sputum, urine or both sputum and urine combined within the first 24 h were 39/139 (28.1 %), 89/139 (64.0 %) and 108/139 (77.7 %) cases, respectively (P <0.001). The very high prevalence of active TB and its non-specific presentation strongly suggest the need for routine microbiological screening for TB in all HIV-positive medical admissions in high-burden settings. The incremental diagnostic yield from Xpert testing urine was very high and this strategy might be used to rapidly screen new admissions, especially if sputum is difficult to obtain.
The social dynamics of genetic testing: the case of Fragile-X.
Nelkin, D
1996-12-01
This article considers a program to screen school children for Fragile-X Syndrome as a way to explore several features of the growing practice of genetic testing in American society. These include the common practice of predictive testing in nonclinical settings; the economic, entrepreneurial, and policy interests that are driving the development of genetic screening programs; and the public support for genetic testing even when there are no effective therapeutic interventions. Drawing from research on popular images of genetics, I argue that cultural beliefs and expectations, widely conveyed through popular narratives, are encouraging the search for diagnostic information and enhancing the appeal of genetic explanations for a growing range of conditions.
2010-01-01
Background Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. Methods A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Results Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. Conclusions The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration. PMID:20684792
Kuwahata, Melissa; Wijesinghe, Rushika; Ho, Mei-Fong; Pelecanos, Anita; Bobogare, Albino; Landry, Losi; Bugora, Hugo; Vallely, Andrew; McCarthy, James
2010-08-05
Glucose-6-phosphate dehydrogenase deficiency poses a significant impediment to primaquine use for the elimination of liver stage infection with Plasmodium vivax and for gametocyte clearance, because of the risk of life-threatening haemolytic anaemia that can occur in G6PD deficient patients. Although a range of methods for screening G6PD deficiency have been described, almost all require skilled personnel, expensive laboratory equipment, freshly collected blood, and are time consuming; factors that render them unsuitable for mass-screening purposes. A published WST8/1-methoxy PMS method was adapted to assay G6PD activity in a 96-well format using dried blood spots, and used it to undertake population screening within a malaria survey undertaken in Isabel Province, Solomon Islands. The assay results were compared to a biochemical test and a recently marketed rapid diagnostic test. Comparative testing with biochemical and rapid diagnostic test indicated that results obtained by filter paper assay were accurate providing that blood spots were assayed within 5 days when stored at ambient temperature and 10 days when stored at 4 degrees. Screening of 8541 people from 41 villages in Isabel Province, Solomon Islands revealed the prevalence of G6PD deficiency as defined by enzyme activity < 30% of normal control was 20.3% and a prevalence of severe deficiency that would predispose to primaquine-induced hemolysis (WHO Class I-II) of 6.9%. The assay enabled simple and quick semi-quantitative population screening in a malaria-endemic region. The study indicated a high prevalence of G6PD deficiency in Isabel Province and highlights the critical need to consider G6PD deficiency in the context of P. vivax malaria elimination strategies in Solomon Islands, particularly in light of the potential role of primaquine mass drug administration.
Diagnosis of aphasia in stroke populations: A systematic review of language tests
2018-01-01
Background and purpose Accurate aphasia diagnosis is important in stroke care. A wide range of language tests are available and include informal assessments, tests developed by healthcare institutions and commercially published tests available for purchase in pre-packaged kits. The psychometrics of these tests are often reported online or within the purchased test manuals, not the peer-reviewed literature, therefore the diagnostic capabilities of these measures have not been systematically evaluated. This review aimed to identify both commercial and non-commercial language tests and tests used in stroke care and to examine the diagnostic capabilities of all identified measures in diagnosing aphasia in stroke populations. Methods Language tests were identified through a systematic search of 161 publisher databases, professional and resource websites and language tests reported to be used in stroke care. Two independent reviewers evaluated test manuals or associated resources for cohort or cross-sectional studies reporting the tests’ diagnostic capabilities (sensitivity, specificity, likelihood ratios or diagnostic odds ratios) in differentiating aphasic and non-aphasic stroke populations. Results Fifty-six tests met the study eligibility criteria. Six “non-specialist” brief screening tests reported sensitivity and specificity information, however none of these measures reported to meet the specific diagnostic needs of speech pathologists. The 50 remaining measures either did not report validity data (n = 7); did not compare patient test performance with a comparison group (n = 17); included non-stroke participants within their samples (n = 23) or did not compare stroke patient performance against a language reference standard (n = 3). Diagnostic sensitivity analysis was completed for six speech pathology measures (WAB, PICA, CADL-2, ASHA-FACS, Adult FAVRES and EFA-4), however all studies compared aphasic performance with that of non-stroke healthy controls and were consequently excluded from the review. Conclusions No speech pathology test was found which reported diagnostic data for identifying aphasia in stroke populations. A diagnostically validated post-stroke aphasia test is needed. PMID:29566043
Marquis-Nicholson, Renate; Lai, Daniel; Love, Jennifer M.; Love, Donald R.
2013-01-01
Purpose. The aim of this study was to develop a streamlined mutation screening protocol for the DMD gene in order to confirm a clinical diagnosis of Duchenne or Becker muscular dystrophy in affected males and to clarify the carrier status of female family members. Methods. Sequence analysis and array comparative genomic hybridization (aCGH) were used to identify mutations in the dystrophin DMD gene. We analysed genomic DNA from six individuals with a range of previously characterised mutations and from eight individuals who had not previously undergone any form of molecular analysis. Results. We successfully identified the known mutations in all six patients. A molecular diagnosis was also made in three of the four patients with a clinical diagnosis who had not undergone prior genetic screening, and testing for familial mutations was successfully completed for the remaining four patients. Conclusion. The mutation screening protocol described here meets best practice guidelines for molecular testing of the DMD gene in a diagnostic laboratory. The aCGH method is a superior alternative to more conventional assays such as multiplex ligation-dependent probe amplification (MLPA). The combination of aCGH and sequence analysis will detect mutations in 98% of patients with the Duchenne or Becker muscular dystrophy. PMID:23476807
Surface electromyography as a screening method for evaluation of dysphagia and odynophagia
Vaiman, Michael; Eviatar, Ephraim
2009-01-01
Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090
Estimating the relative utility of screening mammography.
Abbey, Craig K; Eckstein, Miguel P; Boone, John M
2013-05-01
The concept of diagnostic utility is a fundamental component of signal detection theory, going back to some of its earliest works. Attaching utility values to the various possible outcomes of a diagnostic test should, in principle, lead to meaningful approaches to evaluating and comparing such systems. However, in many areas of medical imaging, utility is not used because it is presumed to be unknown. In this work, we estimate relative utility (the utility benefit of a detection relative to that of a correct rejection) for screening mammography using its known relation to the slope of a receiver operating characteristic (ROC) curve at the optimal operating point. The approach assumes that the clinical operating point is optimal for the goal of maximizing expected utility and therefore the slope at this point implies a value of relative utility for the diagnostic task, for known disease prevalence. We examine utility estimation in the context of screening mammography using the Digital Mammographic Imaging Screening Trials (DMIST) data. We show how various conditions can influence the estimated relative utility, including characteristics of the rating scale, verification time, probability model, and scope of the ROC curve fit. Relative utility estimates range from 66 to 227. We argue for one particular set of conditions that results in a relative utility estimate of 162 (±14%). This is broadly consistent with values in screening mammography determined previously by other means. At the disease prevalence found in the DMIST study (0.59% at 365-day verification), optimal ROC slopes are near unity, suggesting that utility-based assessments of screening mammography will be similar to those found using Youden's index.
Genetic testing in congenital heart disease: A clinical approach
Chaix, Marie A; Andelfinger, Gregor; Khairy, Paul
2016-01-01
Congenital heart disease (CHD) is the most common type of birth defect. Traditionally, a polygenic model defined by the interaction of multiple genes and environmental factors was hypothesized to account for different forms of CHD. It is now understood that the contribution of genetics to CHD extends beyond a single unified paradigm. For example, monogenic models and chromosomal abnormalities have been associated with various syndromic and non-syndromic forms of CHD. In such instances, genetic investigation and testing may potentially play an important role in clinical care. A family tree with a detailed phenotypic description serves as the initial screening tool to identify potentially inherited defects and to guide further genetic investigation. The selection of a genetic test is contingent upon the particular diagnostic hypothesis generated by clinical examination. Genetic investigation in CHD may carry the potential to improve prognosis by yielding valuable information with regards to personalized medical care, confidence in the clinical diagnosis, and/or targeted patient follow-up. Moreover, genetic assessment may serve as a tool to predict recurrence risk, define the pattern of inheritance within a family, and evaluate the need for further family screening. In some circumstances, prenatal or preimplantation genetic screening could identify fetuses or embryos at high risk for CHD. Although genetics may appear to constitute a highly specialized sector of cardiology, basic knowledge regarding inheritance patterns, recurrence risks, and available screening and diagnostic tools, including their strengths and limitations, could assist the treating physician in providing sound counsel. PMID:26981213
Chatzistamatiou, Kimon; Moysiadis, Theodoros; Moschaki, Viktoria; Panteleris, Nikolaos; Agorastos, Theodoros
2016-07-01
The objective of the present study was to identify the most effective cervical cancer screening algorithm incorporating different combinations of cytology, HPV testing and genotyping. Women 25-55years old recruited for the "HERMES" (HEllenic Real life Multicentric cErvical Screening) study were screened in terms of cytology and high-risk (hr) HPV testing with HPV 16/18 genotyping. Women positive for cytology or/and hrHPV were referred for colposcopy, biopsy and treatment. Ten screening algorithms based on different combinations of cytology, HPV testing and HPV 16/18 genotyping were investigated in terms of diagnostic accuracy. Three clusters of algorithms were formed according to the balance between effectiveness and harm caused by screening. The cluster showing the best balance included two algorithms based on co-testing and two based on HPV primary screening with HPV 16/18 genotyping. Among these, hrHPV testing with HPV 16/18 genotyping and reflex cytology (atypical squamous cells of undetermined significance - ASCUS threshold) presented the optimal combination of sensitivity (82.9%) and specificity relative to cytology alone (0.99) with 1.26 false positive rate relative to cytology alone. HPV testing with HPV 16/18 genotyping, referring HPV 16/18 positive women directly to colposcopy, and hrHPV (non 16/18) positive women to reflex cytology (ASCUS threshold), as a triage method to colposcopy, reflects the best equilibrium between screening effectiveness and harm. Algorithms, based on cytology as initial screening method, on co-testing or HPV primary without genotyping, and on HPV primary with genotyping but without cytology triage, are not supported according to the present analysis. Copyright © 2016 Elsevier Inc. All rights reserved.
Nadel, Marion R; Berkowitz, Zahava; Klabunde, Carrie N; Smith, Robert A; Coughlin, Steven S; White, Mary C
2010-08-01
Fecal occult blood testing (FOBT) is an important option for colorectal cancer screening that should be available in order to achieve high population screening coverage. However, results from a national survey of clinical practice in 1999-2000 indicated that many primary care physicians used inadequate methods to implement FOBT screening and follow-up. To determine whether methods to screen for fecal occult blood have improved, including the use of newer more sensitive stool tests. Cross-sectional national survey of primary care physicians. Participants consisted of 1,134 primary care physicians who reported ordering or performing FOBT in the 2006-2007 National Survey of Primary Care Physicians' Recommendations and Practices for Cancer Screening. Self-reported data on details of FOBT implementation and follow-up of positive results. Most physicians report using standard guaiac tests; higher sensitivity guaiac tests and immunochemical tests were reported by only 22.0% and 8.9%, respectively. In-office testing, that is, testing of a single specimen collected during a digital rectal examination in the office, is still widely used although inappropriate for screening: 24.9% of physicians report using only in-office tests and another 52.9% report using both in-office and home tests. Recommendations improved for follow-up after a positive test: fewer physicians recommend repeating the FOBT (17.8%) or using tests other than colonoscopy for the diagnostic work-up (6.6%). Only 44.3% of physicians who use home tests have reminder systems to ensure test completion and return. Many physicians continue to use inappropriate methods to screen for fecal occult blood. Intensified efforts to inform physicians of recommended technique and promote the use of tracking systems are needed.
Landman, Keren Z; Jean, Samuel E; Existe, Alexandre; Akom, Eniko E; Chang, Michelle A; Lemoine, Jean Frantz; Mace, Kimberly E
2015-10-09
Malaria is a public health concern in Haiti, although there are limited data on its burden and case management. National malaria guidelines updated in 2012 recommend treatment with chloroquine and primaquine. In December 2012, a nationally-representative cross-sectional survey of health facilities (HFs) was conducted to determine malaria prevalence among febrile outpatients and malaria case management quality at baseline before scale-up of diagnostics and case management training. Among all 833 HFs nationwide, 30 were selected randomly, in proportion to total HFs per region, for 2-day evaluations. Survey teams inventoried HF material and human resources. Outpatients of all ages were screened for temperature >37.5 °C or history of fever; those without severe symptoms were consented and enrolled. Providers evaluated and treated enrolled patients according to HF standards; the survey teams documented provider-ordered diagnostic tests and treatment decisions. Facility-based test results [microscopy and malaria rapid diagnostic tests (RDTs)] were collected from HF laboratories. Blood smears for gold-standard microscopy, and dried blood spots for polymerase chain reaction (PCR) were obtained. Malaria diagnostic capacity, defined as completing a test for an enrolled patient or having adequate resources for RDTs or microscopy, was present in 11 (37 %) HFs. Among 459 outpatients screened, 257 (56 %) were febrile, of which 193 (75 %) were eligible, and 153 (80 %) were enrolled. Among 39 patients with facility-level malaria test results available on the survey day, 11 (28 %) were positive, of whom 6 (55 %) were treated with an anti-malarial. Twenty-seven (95 %) of the 28 patients testing negative were not treated with an anti-malarial. Of 114 patients without test results available, 35 (31 %) were presumptively treated for malaria. Altogether, 42 patients were treated with an anti-malarial, one (2 %) according to Haiti's 2012 guidelines. Of 140 gold-standard smears, none were positive, although one patient tested positive by PCR, a more sensitive technique. The national prevalence of malaria among febrile outpatients is estimated to be 0.5 % (95 % confidence interval 0-1.7 %). Malaria is an uncommon cause of fever in Haitian outpatients, and limited, often inaccurate, diagnostic capacity at baseline contributes to over diagnosis. Scale-up of diagnostics and training on new guidelines should improve malaria diagnosis and treatment in Haiti.
Dendukuri, Nandini; Cheeran, Jacob Varghese; Sukumar, Raman
2012-01-01
Background Mycobacterium tuberculosis, a causative agent of chronic tuberculosis disease, is widespread among some animal species too. There is paucity of information on the distribution, prevalence and true disease status of tuberculosis in Asian elephants (Elephas maximus). The aim of this study was to estimate the sensitivity and specificity of serological tests to diagnose M. tuberculosis infection in captive elephants in southern India while simultaneously estimating sero-prevalence. Methodology/Principal Findings Health assessment of 600 elephants was carried out and their sera screened with a commercially available rapid serum test. Trunk wash culture of select rapid serum test positive animals yielded no animal positive for M. tuberculosis isolation. Under Indian field conditions where the true disease status is unknown, we used a latent class model to estimate the diagnostic characteristics of an existing (rapid serum test) and new (four in-house ELISA) tests. One hundred and seventy nine sera were randomly selected for screening in the five tests. Diagnostic sensitivities of the four ELISAs were 91.3–97.6% (95% Credible Interval (CI): 74.8–99.9) and diagnostic specificity were 89.6–98.5% (95% CI: 79.4–99.9) based on the model we assumed. We estimate that 53.6% (95% CI: 44.6–62.8) of the samples tested were free from infection with M. tuberculosis and 15.9% (97.5% CI: 9.8 - to 24.0) tested positive on all five tests. Conclusions/Significance Our results provide evidence for high prevalence of asymptomatic M. tuberculosis infection in Asian elephants in a captive Indian setting. Further validation of these tests would be important in formulating area-specific effective surveillance and control measures. PMID:23166708
Verma-Kumar, Shalu; Abraham, David; Dendukuri, Nandini; Cheeran, Jacob Varghese; Sukumar, Raman; Balaji, Kithiganahalli Narayanaswamy
2012-01-01
Mycobacterium tuberculosis, a causative agent of chronic tuberculosis disease, is widespread among some animal species too. There is paucity of information on the distribution, prevalence and true disease status of tuberculosis in Asian elephants (Elephas maximus). The aim of this study was to estimate the sensitivity and specificity of serological tests to diagnose M. tuberculosis infection in captive elephants in southern India while simultaneously estimating sero-prevalence. Health assessment of 600 elephants was carried out and their sera screened with a commercially available rapid serum test. Trunk wash culture of select rapid serum test positive animals yielded no animal positive for M. tuberculosis isolation. Under Indian field conditions where the true disease status is unknown, we used a latent class model to estimate the diagnostic characteristics of an existing (rapid serum test) and new (four in-house ELISA) tests. One hundred and seventy nine sera were randomly selected for screening in the five tests. Diagnostic sensitivities of the four ELISAs were 91.3-97.6% (95% Credible Interval (CI): 74.8-99.9) and diagnostic specificity were 89.6-98.5% (95% CI: 79.4-99.9) based on the model we assumed. We estimate that 53.6% (95% CI: 44.6-62.8) of the samples tested were free from infection with M. tuberculosis and 15.9% (97.5% CI: 9.8 - to 24.0) tested positive on all five tests. Our results provide evidence for high prevalence of asymptomatic M. tuberculosis infection in Asian elephants in a captive Indian setting. Further validation of these tests would be important in formulating area-specific effective surveillance and control measures.
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE. PMID:28273146
Jeong, Seri; Yang, Heeyoung; Hwang, Hyunyong
2017-01-01
This study aimed to evaluate the diagnostic utilities of the automated connective tissues disease screening assay, CTD screen, in patients with systemic rheumatic diseases. A total of 1093 serum samples were assayed using CTD screen and indirect immunofluorescent (IIF) methods. Among them, 162 were diagnosed with systemic rheumatic disease, including rheumatoid arthritis (RA), systemic lupus erythematosus (SLE), and mixed connective tissue disease (MCT). The remaining 931 with non-systemic rheumatic disease were assigned to the control group. The median ratios of CTD screen tests were significantly higher in the systemic rheumatic disease group than in the control group. The positive likelihood ratios of the CTD screen were higher than those of IIF in patients with total rheumatic diseases (4.1 vs. 1.6), including SLE (24.3 vs. 10.7). The areas under the receiver operating characteristic curves (ROC-AUCs) of the CTD screen for discriminating total rheumatic diseases, RA, SLE, and MCT from controls were 0.68, 0.56, 0.92 and 0.80, respectively. The ROC-AUCs of the combinations with IIF were significantly higher in patients with total rheumatic diseases (0.72) and MCT (0.85) than in those of the CTD screen alone. Multivariate analysis indicated that both the CTD screen and IIF were independent variables for predicting systemic rheumatic disease. CTD screen alone and in combination with IIF were a valuable diagnostic tool for predicting systemic rheumatic diseases, particularly for SLE.
Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Roy, Jean-Sébastien; Desmeules, François
2017-01-01
More evidence on diagnostic validity of physical examination tests for knee disorders is needed to lower frequently used and costly imaging tests. To conduct a systematic review of systematic reviews (SR) and meta-analyses (MA) evaluating the diagnostic validity of physical examination tests for knee disorders. A structured literature search was conducted in five databases until January 2016. Methodological quality was assessed using the AMSTAR. Seventeen reviews were included with mean AMSTAR score of 5.5 ± 2.3. Based on six SR, only the Lachman test for ACL injuries is diagnostically valid when individually performed (Likelihood ratio (LR+):10.2, LR-:0.2). Based on two SR, the Ottawa Knee Rule is a valid screening tool for knee fractures (LR-:0.05). Based on one SR, the EULAR criteria had a post-test probability of 99% for the diagnosis of knee osteoarthritis. Based on two SR, a complete physical examination performed by a trained health provider was found to be diagnostically valid for ACL, PCL and meniscal injuries as well as for cartilage lesions. When individually performed, common physical tests are rarely able to rule in or rule out a specific knee disorder, except the Lachman for ACL injuries. There is low-quality evidence concerning the validity of combining history elements and physical tests. Copyright © 2016 Elsevier Ltd. All rights reserved.
Testing for Drug Hypersensitivity Syndromes
Rive, Craig M; Bourke, Jack; Phillips, Elizabeth J
2013-01-01
Adverse drug reactions are a common cause of patient morbidity and mortality. Type B drug reactions comprise only 20% of all drug reactions but they tend to be primarily immunologically mediated and less dependent on the drug’s pharmacological action and dose. Common Type B reactions seen in clinical practice are those of the immediate, IgE, Gell-Coombs Type I reactions, and the delayed, T-cell mediated, Type IV reactions. Management of these types of reactions, once they have occurred, requires careful consideration and recognition of the utility of routine diagnostic tests followed by ancillary specialised diagnostic testing. For Type I, IgE mediated reactions this includes prick/intradermal skin testing and oral provocation. For Type IV, T-cell mediated reactions this includes a variety of in vivo (patch testing) and ex vivo tests, many of which are currently mainly used in highly specialised research laboratories. The recent association of many serious delayed (Type IV) hypersensitivity reactions to specific drugs with HLA class I and II alleles has created the opportunity for HLA screening to exclude high risk populations from exposure to the implicated drug and hence prevent clinical reactions. For example, the 100% negative predictive value of HLA-B*5701 for true immunologically mediated abacavir hypersensitivity and the development of feasible, inexpensive DNA-based molecular tests has led to incorporation of HLA-B*5701 screening in routine HIV clinical practice. The mechanism by which drugs specifically interact with HLA has been recently characterised and promises to lead to strategies for pre-clinical screening to inform drug development and design. PMID:23592889
Terrazas, Solana; Ibáñez, Carolina; Lagos, Marcela; Poggi, Helena; Brañes, Jorge; Barriga, María Isabel; Cartagena, Jaime; Núñez, Felipe; González, Francisca; Cook, Paz; Van De Wyngard, Vanessa; Ferreccio, Catterina
2015-01-01
Molecular techniques for human papillomavirus (HPV) detection have a good performance as screening tests and could be included in cervical cancer early detection programs. We conducted a population-based trial comparing HPV detection and Papanicolaou as primary screening tests, in a public health service in Santiago, Chile. To describe the experience of implementing this new molecular test and present the main results of the study. Women aged 25 to 64 enrolled in three public health centers were invited to participate. In all women, samples were collected for Papanicolaou and HPV DNA testing, and naked-eye visual inspection of the cervix with acetic acid was performed. Women with any positive screening test were referred to the local area hospital for diagnostic confirmation with colposcopy and biopsy of suspicious lesions. Screening results were obtained for 8265 women, of whom 931 (11.3%) were positive to any test. The prevalence of cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was 1.1%; nine women had invasive cervical cancer. Sensitivities for the detection of CIN2+ were 22.1% (95% confidence interval (CI) 16.4-29.2) for Papanicolaou and 92.7% (95% CI 84.4-96.8) for HPV testing; specificities were 98.9% (95% CI 98.7-99.0) and 92.0% (95% CI 91.4-92.6) respectively. This experience showed that the implementation of a molecular test for cervical cancer screening is not a major challenge in Chile: it was well accepted by both the health team and the participants, and it may improve the effectiveness of the screening program.
2007-01-01
Objective To evaluate the feasibility and diagnostic accuracy of screening for coeliac disease by rapid detection of IgA antibodies to tissue transglutaminase performed in primary care. Design District nurses screened 6 year old children using rapid antibody testing of finger prick blood. They also collected capillary blood samples for laboratory determination of IgA and IgG antibodies to endomysium and IgA antibodies to tissue transglutaminase. Children with positive rapid test results were directly sent for biopsy of the small intestine. Setting Primary care in Jász-Nagykun-Szolnok county, Hungary. Participants 2690 children (77% of 6 year olds living in the county) and 120 nurses. Main outcome measures Positivity for antibodies to endomysium or transglutaminase in the laboratory and coeliac disease confirmed at biopsy. Results 37 children (1.4%, 95% confidence interval 0.9% to 1.8%) had biopsy confirmed coeliac disease. Only five of these children had been diagnosed clinically before screening. Rapid testing had a 78.1% sensitivity (70.0% to 89.3%) and 100% specificity (88.4% to 100%) for a final diagnosis of coeliac disease by biopsy. Sensitivity was 65.1% (50.2% to 77.6%) and specificity was 100% (99.8% to 100%) compared with combined results of IgA and IgG laboratory tests. Trained laboratory workers detected 30 of the 31 newly diagnosed IgA competent patients with the rapid test kit used blindly. Median time to biopsy after a positive rapid test result was significantly shorter (20 days, range 4-148) than after a positive laboratory result (142 days, 70-256; P<0.001). Children with coeliac disease detected at screening were smaller and had worse health status than their peers but they improved on a gluten-free diet. Conclusions A simple rapid antibody test enabled primary care nurses to detect patients with coeliac disease in the community who were not picked up in clinical care. Extra training is needed to improve sensitivity. PMID:18063612
Validation of the Danish Addenbrooke's Cognitive Examination as a screening test in a memory clinic.
Stokholm, Jette; Vogel, Asmus; Johannsen, Peter; Waldemar, Gunhild
2009-01-01
Addenbrooke's Cognitive Examination (ACE) is a cognitive screening test developed to detect dementia. It has been validated in several countries. Validation studies have predominantly included patients with various degrees of dementia and healthy controls. The aim of this study was to evaluate the Danish version of ACE as a screening test for early dementia in an outpatient memory clinic. Further, we wanted to investigate the ability of the ACE to discriminate patients with early Alzheimer's disease (AD) from patients with depression. 78 patients with mild AD (MMSE >or=20), 30 non-demented patients diagnosed with depression (originally referred for evaluation of cognitive symptoms), and 63 healthy volunteers, all between 60 and 85 years of age, were included. All patients were given the ACE as a supplement to the standard diagnostic work-up. The cut-off points for optimal trade-off between sensitivity and specificity for ACE were 85/86 (sensitivity 0.99, specificity 0.94). When these cut-off points were applied to the group of depressive patients, the specificity dropped to 0.64, indicating a great overlap in individual test scores for demented and depressed patients. The optimal cut-off points for ACE found in this Danish study were close to what is reported in most other European studies. The great overlap in ACE scores for demented and depressed patients emphasize that test scores must be interpreted with great caution when used in diagnostic work-up.
Crome, Erica; Baillie, Andrew
2015-01-01
The prevalence of social anxiety disorder (SAD) is frequently higher in younger age groups and people with other anxiety or mood disorders; however, it is unclear whether these groups have a higher risk for developing SAD or are simply more likely to endorse diagnostic criteria than other people with similar levels of social anxiety. Explicitly testing the assumption all people respond to structured diagnostic interviews in comparable ways (measurement invariance) is essential in ensuring systematic response biases do not create spurious group differences. This research aims to systematically test whether age, comorbidity status, or types of social fears affect responses to a structured diagnostic interview. Responses from 1755 participants in a large-scale survey of mental health in Australia screening into the social phobia/SAD section of the Composite International Diagnostic Interview were used. Three series of multigroup confirmatory factor analyses for categorical data systematically tested for increasingly strict levels of measurement invariance. Overall, patterns of responding to diagnostic criteria were comparable across the groups, supporting assumptions of measurement invariance. Establishment of invariance supports the interpretation of differences between age, comorbidity status, and types of social situations feared as genuine differences in experience as opposed to measurement biases.
Abbreviated Combined MR Protocol: A New Faster Strategy for Characterizing Breast Lesions.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2016-06-01
The use of an abbreviated magnetic resonance (MR) protocol has been recently proposed for cancer screening. The aim of our study is to evaluate the diagnostic accuracy of an abbreviated MR protocol combining short TI inversion recovery (STIR), turbo-spin-echo (TSE)-T2 sequences, a pre-contrast T1, and a single intermediate (3 minutes after contrast injection) post-contrast T1 sequence for characterizing breast lesions. A total of 470 patients underwent breast MR examination for screening, problem solving, or preoperative staging. Two experienced radiologists evaluated both standard and abbreviated protocols in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for both protocols were calculated (with the histological findings and 6-month ultrasound follow-up as the reference standard) and compared with the McNemar test. The post-processing and interpretation times for the MR images were compared with the paired t test. In 177 of 470 (38%) patients, the MR sequences detected 185 breast lesions. Standard and abbreviated protocols obtained sensitivity, specificity, diagnostic accuracy, PPV, and NPV values respectively of 92%, 92%, 92%, 68%, and 98% and of 89%, 91%, 91%, 64%, and 98% with no statistically significant difference (P < .0001). The mean post-processing and interpretation time were, respectively, 7 ± 1 minutes and 6 ± 3.2 minutes for the standard protocol and 1 ± 1.2 minutes and 2 ± 1.2 minutes for the abbreviated protocol, with a statistically significant difference (P < .01). An abbreviated combined MR protocol represents a time-saving tool for radiologists and patients with the same diagnostic potential as the standard protocol in patients undergoing breast MRI for screening, problem solving, or preoperative staging. Copyright © 2016 Elsevier Inc. All rights reserved.
Legleye, Stéphane
2018-06-01
The Cannabis Abuse Screening Test (CAST) aims at screening the problematic use of cannabis. It has never been validated against the Diagnostic and Statistical Manual of Mental Disorders (DSM)-5 and its relationships with this latter have never been studied. We used a probabilistic telephone survey collected in 2014 (1351 past-year cannabis users aged 15-64) implementing the CAST and a DSM-5 adaptation of the Munich Composite International Diagnostic Interview assessing cannabis use disorders. Data were weighted, and CAST items were considered categorical. Factorial structures were assessed with confirmatory factor analyses; the relationships between the instruments were studied with multiple factor analysis (MFA). One factor for the DSM-5 and two correlated factors for the CAST were the best confirmatory factor analyses solutions. The CAST thresholds for screening moderate/severe and severe cannabis use disorders were 5 (sensitivity = 78.2% and specificity = 79.6%) and 8 (sensitivity = 86.0% and specificity = 86.7%), respectively. The MFA identified two orthogonal dimensions: The first was equally shared by both instruments; the second was the second CAST dimension (extreme frequencies of use before midday and alone, memory problems, and reproaches from friends/family). The CAST structure and screening properties were confirmed. The MFA explains its screening performances by its first dimension and identified the problematic patterns (the second dimension) that are not captured by the DSM-5. Copyright © 2017 John Wiley & Sons, Ltd.
Endoscopy in screening for digestive cancer
Lambert, René
2012-01-01
The aim of this study is to describe the role of endoscopy in detection and treatment of neoplastic lesions of the digestive mucosa in asymptomatic persons. Esophageal squamous cell cancer occurs in relation to nutritional deficiency and alcohol or tobacco consumption. Esophageal adenocarcinoma develops in Barrett’s esophagus, and stomach cancer in chronic gastric atrophy with Helicobacter pylori infection. Colorectal cancer is favoured by a high intake in calories, excess weight, low physical activity. In opportunistic or individual screening endoscopy is the primary detection procedure offered to an asymptomatic individual. In organized or mass screening proposed by National Health Authorities to a population, endoscopy is performed only in persons found positive to a filter selection test. The indications of primary upper gastrointestinal endoscopy and colonoscopy in opportunistic screening are increasingly developing over the world. Organized screening trials are proposed in some regions of China at high risk for esophageal cancer; the selection test is cytology of a balloon or sponge scrapping; they are proposed in Japan for stomach cancer with photofluorography as a selection test; and in Europe, America and Japan; for colorectal cancer with the fecal occult blood test as a selection test. Organized screening trials in a country require an evaluation: the benefit of the intervention assessed by its impact on incidence and on the 5 year survival for the concerned tumor site; in addition a number of bias interfering with the evaluation have to be controlled. Drawbacks of screening are in the morbidity of the diagnostic and treatment procedures and in overdetection of none clinically relevant lesions. The strategy of endoscopic screening applies to early cancer and to benign adenomatous precursors of adenocarcinoma. Diagnostic endoscopy is conducted in 2 steps: at first detection of an abnormal area through changes in relief, in color or in the course of superficial capillaries; then characterization of the morphology of the lesion according to the Paris classification and prediction of the risk of malignancy and depth of invasion, with the help of chromoscopy, magnification and image processing with neutrophil bactericidal index or FICE. Then treatment decision offers 3 options according to histologic prediction: abstention, endoscopic resection, surgery. The rigorous quality control of endoscopy will reduce the miss rate of lesions and the occurrence of interval cancer. PMID:23293721
Endeshaw, Tekola; Graves, Patricia M.; Ayele, Berhan; Mosher, Aryc W.; Gebre, Teshome; Ayalew, Firew; Genet, Asrat; Mesfin, Alemayehu; Shargie, Estifanos Biru; Tadesse, Zerihun; Teferi, Tesfaye; Melak, Berhanu; Richards, Frank O.; Emerson, Paul M.
2012-01-01
Background Diagnostic tests are recommended for suspected malaria cases before treatment, but comparative performance of microscopy and rapid diagnostic tests (RDTs) at rural health centers has rarely been studied compared to independent expert microscopy. Methods Participants (N = 1997) with presumptive malaria were recruited from ten health centers with a range of transmission intensities in Amhara Regional State, Northwest Ethiopia during October to December 2007. Microscopy and ParaScreen Pan/Pf® RDT were done immediately by health center technicians. Blood slides were re-examined later at a central laboratory by independent expert microscopists. Results Of 1,997 febrile patients, 475 (23.8%) were positive by expert microscopists, with 57.7% P.falciparum, 24.6% P.vivax and 17.7% mixed infections. Sensitivity of health center microscopists for any malaria species was >90% in five health centers (four of which had the highest prevalence), >70% in nine centers and 44% in one site with lowest prevalence. Specificity for health center microscopy was very good (>95%) in all centers. For ParaScreen RDT, sensitivity was ≥90% in three centers, ≥70% in six and <60% in four centers. Specificity was ≥90% in all centers except one where it was 85%. Conclusions Health center microscopists performed well in nine of the ten health centers; while for ParaScreen RDT they performed well in only six centers. Overall the accuracy of local microscopy exceeded that of RDT for all outcomes. This study supports the introduction of RDTs only if accompanied by appropriate training, frequent supervision and quality control at all levels. Deficiencies in RDT use at some health centers must be rectified before universal replacement of good routine microscopy with RDTs. Maintenance and strengthening of good quality microscopy remains a priority at health center level. PMID:22536317
Endeshaw, Tekola; Graves, Patricia M; Ayele, Berhan; Mosher, Aryc W; Gebre, Teshome; Ayalew, Firew; Genet, Asrat; Mesfin, Alemayehu; Shargie, Estifanos Biru; Tadesse, Zerihun; Teferi, Tesfaye; Melak, Berhanu; Richards, Frank O; Emerson, Paul M
2012-01-01
Diagnostic tests are recommended for suspected malaria cases before treatment, but comparative performance of microscopy and rapid diagnostic tests (RDTs) at rural health centers has rarely been studied compared to independent expert microscopy. Participants (N = 1997) with presumptive malaria were recruited from ten health centers with a range of transmission intensities in Amhara Regional State, Northwest Ethiopia during October to December 2007. Microscopy and ParaScreen Pan/Pf® RDT were done immediately by health center technicians. Blood slides were re-examined later at a central laboratory by independent expert microscopists. Of 1,997 febrile patients, 475 (23.8%) were positive by expert microscopists, with 57.7% P. falciparum, 24.6% P. vivax and 17.7% mixed infections. Sensitivity of health center microscopists for any malaria species was >90% in five health centers (four of which had the highest prevalence), >70% in nine centers and 44% in one site with lowest prevalence. Specificity for health center microscopy was very good (>95%) in all centers. For ParaScreen RDT, sensitivity was ≥90% in three centers, ≥70% in six and <60% in four centers. Specificity was ≥90% in all centers except one where it was 85%. Health center microscopists performed well in nine of the ten health centers; while for ParaScreen RDT they performed well in only six centers. Overall the accuracy of local microscopy exceeded that of RDT for all outcomes. This study supports the introduction of RDTs only if accompanied by appropriate training, frequent supervision and quality control at all levels. Deficiencies in RDT use at some health centers must be rectified before universal replacement of good routine microscopy with RDTs. Maintenance and strengthening of good quality microscopy remains a priority at health center level.
Bauer, Lyndsey; O'Bryant, Sid E; Lynch, Julie K; McCaffrey, Robert J; Fisher, Jerid M
2007-09-01
Assessing effort level during neuropsychological evaluations is critical to support the accuracy of cognitive test scores. Many instruments are designed to measure effort, yet they are not routinely administered in neuropsychological assessments. The Test of Memory Malingering (TOMM) and the Word Memory Test (WMT) are commonly administered symptom validity tests with sound psychometric properties. This study examines the use of the TOMM Trial 1 and the WMT Immediate Recognition (IR) trial scores as brief screening tools for insufficient effort through an archival analysis of a combined sample of mild head-injury litigants ( N = 105) who were assessed in forensic private practices. Results show that both demonstrate impressive diagnostic accuracy and calculations of positive and negative predictive power are presented for a range of base rates. These results support the utility of Trial 1 of the TOMM and the WMT IR trial as screening methods for the assessment of insufficient effort in neuropsychological assessments.
Wiwanitkit, Viroj; Udomsantisuk, Nibhond; Boonchalermvichian, Chaiyaporn
2005-06-01
The aim of this study was to evaluate the diagnostic properties of urine Gram stain and urine microscopic examination for screening for urinary tract infection (UTI), and to perform an additional cost utility analysis. This descriptive study was performed on 95 urine samples sent for urine culture to the Department of Microbiology, Faculty of Medicine, Chulalongkorn University. The first part of the study was to determine the diagnostic properties of two screening tests (urine Gram stain and urine microscopic examination). Urine culture was set as the gold standard and the results from both methods were compared to this. The second part of this study was to perform a cost utility analysis. The sensitivity of urine Gram stain was 96.2%, the specificity 93.0%, the positive predictive value 94.3% and the negative predictive value 95.2%. False positives occurred with a frequency of 7.0% and false negatives 3.8%. For the microscopic examination, the sensitivity was 65.4%, specificity 74.4%, positive predictive value 75.6% and negative predictive value 64.0%. False positives occurred with a frequency of 25.6% and false negatives 34.6%. Combining urine Gram stain and urine microscopic examination, the sensitivity was 98.1%, specificity 74.4%, positive predictive value 82.3% and negative predictive value 97.0%. False positives occurred with a frequency of 25.6% and false negatives 1.9%. However, the cost per utility of the combined method was higher than either urine microscopic examination or urine Gram stain alone. Urine Gram stain provided the lowest cost per utility. Economically, urine Gram stain is the proper screening tool for presumptive diagnosis of UTI.
Chen, Hongda; Zucknick, Manuela; Werner, Simone; Knebel, Phillip; Brenner, Hermann
2015-07-15
Novel noninvasive blood-based screening tests are strongly desirable for early detection of colorectal cancer. We aimed to conduct a head-to-head comparison of the diagnostic performance of 92 plasma-based tumor-associated protein biomarkers for early detection of colorectal cancer in a true screening setting. Among all available 35 carriers of colorectal cancer and a representative sample of 54 men and women free of colorectal neoplasms recruited in a cohort of screening colonoscopy participants in 2005-2012 (N = 5,516), the plasma levels of 92 protein biomarkers were measured. ROC analyses were conducted to evaluate the diagnostic performance. A multimarker algorithm was developed through the Lasso logistic regression model and validated in an independent validation set. The .632+ bootstrap method was used to adjust for the potential overestimation of diagnostic performance. Seventeen protein markers were identified to show statistically significant differences in plasma levels between colorectal cancer cases and controls. The adjusted area under the ROC curves (AUC) of these 17 individual markers ranged from 0.55 to 0.70. An eight-marker classifier was constructed that increased the adjusted AUC to 0.77 [95% confidence interval (CI), 0.59-0.91]. When validating this algorithm in an independent validation set, the AUC was 0.76 (95% CI, 0.65-0.85), and sensitivities at cutoff levels yielding 80% and 90% specificities were 65% (95% CI, 41-80%) and 44% (95% CI, 24-72%), respectively. The identified profile of protein biomarkers could contribute to the development of a powerful multimarker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.
Schwope, David M.; Milman, Garry; Huestis, Marilyn A.
2011-01-01
BACKGROUND Oral fluid (OF) is gaining prominence as an alternative matrix for monitoring drugs of abuse in the workplace, criminal justice, and driving under the influence of drugs programs. It is important to characterize assay performance and limitations of screening techniques for Δ9-tetrahydrocannabinol (THC) in OF. METHODS We collected OF specimens by use of the Quantisal™ OF collection device from 13 daily cannabis users after controlled oral cannabinoid administration. All specimens were tested with the Immunalysis Sweat/OF THC Direct ELISA and confirmed by 2-dimensional GC-MS. RESULTS The limit of detection was <1 µg/L THC equivalent, and the assay demonstrated linearity from 1 to 50 µg/L, with semiquantification to 200 µg/L. Intraplate imprecision (n = 7) ranged from 2.9% to 7.7% CV, and interplate imprecision (n = 20) was 3.0%–9.1%. Cross-reactivities at 4 µg/L were as follows: 11-hydroxy-THC, 198%; Δ8-tetrahydrocannabinol (Δ8-THC), 128%; 11-nor-9-carboxy-THC (THCCOOH), 121%; THC (target), 98%; cannabinol, 87%; THCCOOH-glucuronide, 11%; THC-glucuronide, 10%; and cannabidiol, 2.4%. Of 499 tested OF specimens, 52 confirmed positive (THC 2.0–290 µg/L), with 100% diagnostic sensitivity at the proposed Substance Abuse and Mental Health Services Administration screening cutoff of 4 µg/L cannabinoids and GC-MS cutoff of 2 µg/L THC. Forty-seven specimens screened positive but were not confirmed by 2D-GC-MS, yielding 89.5% diagnostic specificity and 90.6% diagnostic efficiency. Thirty-one of 47 unconfirmed immunoassay positive specimens were from 1 individual and contained >400 ng/L THCCOOH, potentially contributing to cross-reactivity. CONCLUSIONS The Immunalysis Sweat/OF THC Direct ELISA is an effective screening procedure for detecting cannabinoids in OF. PMID:20360126
Code of Federal Regulations, 2013 CFR
2013-01-01
... Nitrate/nitrite Test 66.00 67.00 68.00 70.00 72.00 Organic compound confirmation Test 88.00 90.00 92.00 94.00 96.00 Organic compound screen Test 151.00 155.00 158.00 161.00 165.00 Parasitology Test 29.00 29....00 103.00 105.00 107.00 Selenium Test 44.00 45.00 46.00 47.00 48.00 Silicate/carbonate disinfectant...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Nitrate/nitrite Test 66.00 67.00 68.00 70.00 72.00 Organic compound confirmation Test 88.00 90.00 92.00 94.00 96.00 Organic compound screen Test 151.00 155.00 158.00 161.00 165.00 Parasitology Test 29.00 29....00 103.00 105.00 107.00 Selenium Test 44.00 45.00 46.00 47.00 48.00 Silicate/carbonate disinfectant...
Code of Federal Regulations, 2014 CFR
2014-01-01
... Nitrate/nitrite Test 66.00 67.00 68.00 70.00 72.00 Organic compound confirmation Test 88.00 90.00 92.00 94.00 96.00 Organic compound screen Test 151.00 155.00 158.00 161.00 165.00 Parasitology Test 29.00 29....00 103.00 105.00 107.00 Selenium Test 44.00 45.00 46.00 47.00 48.00 Silicate/carbonate disinfectant...
Nah, Yong-Hwee; Young, Robyn L; Brewer, Neil; Berlingeri, Genna
2014-03-01
The Autism Detection in Early Childhood (ADEC; Young, 2007) was developed as a Level 2 clinician-administered autistic disorder (AD) screening tool that was time-efficient, suitable for children under 3 years, easy to administer, and suitable for persons with minimal training and experience with AD. A best estimate clinical Diagnostic and Statistical Manual of Mental Disorders (4th ed., text rev.; DSM-IV-TR; American Psychiatric Association, 2000) diagnosis of AD was made for 70 children using all available information and assessment results, except for the ADEC data. A screening study compared these children on the ADEC with 57 children with other developmental disorders and 64 typically developing children. Results indicated high internal consistency (α = .91). Interrater reliability and test-retest reliability of the ADEC were also adequate. ADEC scores reliably discriminated different diagnostic groups after controlling for nonverbal IQ and Vineland Adaptive Behavior Composite scores. Construct validity (using exploratory factor analysis) and concurrent validity using performance on the Autism Diagnostic Observation Schedule (Lord et al., 2000), the Autism Diagnostic Interview-Revised (Le Couteur, Lord, & Rutter, 2003), and DSM-IV-TR criteria were also demonstrated. Signal detection analysis identified the optimal ADEC cutoff score, with the ADEC identifying all children who had an AD (N = 70, sensitivity = 1.0) but overincluding children with other disabilities (N = 13, specificity ranging from .74 to .90). Together, the reliability and validity data indicate that the ADEC has potential to be established as a suitable and efficient screening tool for infants with AD. 2014 APA
Significance of HbA1c and its measurement in the diagnosis of diabetes mellitus: US experience.
Juarez, Deborah Taira; Demaris, Kendra M; Goo, Roy; Mnatzaganian, Christina Louise; Wong Smith, Helen
2014-01-01
The 2014 American Diabetes Association guidelines denote four means of diagnosing diabetes. The first of these is a glycosylated hemoglobin (HbA1c) >6.5%. This literature review summarizes studies (n=47) in the USA examining the significance, strengths, and limitations of using HbA1c as a diagnostic tool for diabetes, relative to other available means. Due to the relatively recent adoption of HbA1c as a diabetes mellitus diagnostic tool, a hybrid systematic, truncated review of the literature was implemented. Based on these studies, we conclude that HbA1c screening for diabetes has been found to be convenient and effective in diagnosing diabetes. HbA1c screening is particularly helpful in community-based and acute care settings where tests requiring fasting are not practical. Using HbA1c to diagnose diabetes also has some limitations. For instance, HbA1c testing may underestimate the prevalence of diabetes, particularly among whites. Because this bias differs by racial group, prevalence and resulting estimates of health disparities based on HbA1c screening differ from those based on other methods of diagnosis. In addition, existing evidence suggests that HbA1c screening may not be valid in certain subgroups, such as children, women with gestational diabetes, patients with human immunodeficiency virus, and those with prediabetes. Further guidelines are needed to clarify the appropriate use of HbA1c screening in these populations.
Cushing's Syndrome: Screening and Diagnosis.
Ceccato, Filippo; Boscaro, Marco
2016-09-01
Endogenous Cushing's syndrome (CS) is a rare disease, and usually characterized by hypertension, diabetes, obesity, osteoporosis, facial rounding, dorsocervical fat pad, thin skin, purple striae, hirsutism, and mood disorders. Efficient diagnostic and screening strategies lead to the diagnosis of a significantly higher number of cases of CS. As a screening test for CS, the Endocrine Society's Clinical Practice Guidelines recommend a single test with a high diagnostic accuracy, among the 1-mg dexamethasone suppression test (1-mg DST), late night salivary cortisol (LNSC), and 24 h urinary free cortisol (UFC). In normal subjects, administering a higher than physiological dose of glucocorticoids prompts the suppression of cortisol secretion. The 1-mg DST explores this normal feedback reaction from the hypothalamic-pituitary-adrenal axis (HPA). It is a simple dynamic test, usually performed in outpatients. A morning serum cortisol level <50 nmol/L suffices to exclude CS, unless there is a strong clinical suspicion to suggest otherwise. The HPA axis reaches a nadir just after a person has fallen asleep, but its circadian rhythm is impaired in CS patients, who feature higher cortisol values at night, which are easy to measure in saliva (the LNSC assay). Saliva collection is also suitable for outpatients since cortisol is stable at room temperature and the collection device can be mailed to the laboratory for analysis. UFC levels reflect the integrated tissue exposure to free cortisol over 24 h, and thus provide a particular picture of endogenous hypercortisolism. In most cases, high UFC levels coincide with severe hypercortisolism. UFC is used not only to diagnose CS, but also to monitor its response to medical treatment. All screening tests have procedural snares: some drugs can interfere with the DST; false-positive or false-negative LNSC results may be due to an inadequate soaking of the device or to cyclic CS; and in the case of UFC it is important to ensure that patients provide complete urine collections with appropriate total volumes. Measuring cortisol with antibody-based immunoassays can also generate false-positive results due to cross-reactivity between cortisol, cortisone and other metabolites. Structurally-based assays, such as liquid chromatography with tandem mass spectrometry, only measure cortisol and have only recently become available for use in routine clinical practice. This review summarizes the recent literature on the clinical and biochemical aspects of CS diagnostics with a view to helping physicians choose the best screening test for diagnosing endogenous hypercortisolism.
Díaz-Orueta, Unai; Blanco-Campal, Alberto; Burke, Teresa
2018-05-01
ABSTRACTBackground:A detailed neuropsychological assessment plays an important role in the diagnostic process of Mild Cognitive Impairment (MCI). However, available brief cognitive screening tests for this clinical population are administered and interpreted based mainly, or exclusively, on total achievement scores. This score-based approach can lead to erroneous clinical interpretations unless we also pay attention to the test taking behavior or to the type of errors committed during test performance. The goal of the current study is to perform a rapid review of the literature regarding cognitive screening tools for dementia in primary and secondary care; this will include revisiting previously published systematic reviews on screening tools for dementia, extensive database search, and analysis of individual references cited in selected studies. A subset of representative screening tools for dementia was identified that covers as many cognitive functions as possible. How these screening tools overlap with each other (in terms of the cognitive domains being measured and the method used to assess them) was examined and a series of process-based approach (PBA) modifications for these overlapping features was proposed, so that the changes recommended in relation to one particular cognitive task could be extrapolated to other screening tools. It is expected that future versions of cognitive screening tests, modified using a PBA, will highlight the benefits of attending to qualitative features of test performance when trying to identify subtle features suggestive of MCI and/or dementia.
Role of Urine Drug Testing in the Current Opioid Epidemic.
Mahajan, Gagan
2017-12-01
While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.
Vordenbäumen, Stefan; Lueking, Angelika; Budde, Petra; Zucht, Hans-Dieter; Goehler, Heike; Brinks, Ralph; Fischer-Betz, Rebecca; Richter, Jutta; Bleck, Ellen; Detert, Jacqueline; Langer, Hans-Eckhard; Sörgel, Anne; Burmester, Gerd-Rüdiger; Schulz-Knappe, Peter; Schneider, Matthias
2016-10-12
The aim was to identify novel diagnostic autoantibody candidates for rheumatoid arthritis (RA) by comprehensive screening for autoreactivity. We incubated 5892 recombinant proteins coupled to fluorescent beads, with patients' sera for the detection of IgG-autoantibodies in three independent patient cohorts: A (n = 72 patients with established RA); B/B- (n = 116 patients with early RA (B) and n = 51 CCP-negative patients with early RA from B (B-)); and C (n = 184 patients with early seronegative RA), in comparison to matched healthy controls. Intersects of significantly increased autoantibodies as determined by the Mann-Whitney test were sought. Screening of 5892 antigens in RA cohorts A and B, or the seronegative cohorts B- and C revealed intersects of 23 and 13 significantly increased autoantibodies, respectively. Reactivity to three antigens was increased in all cohorts tested: N-acetylglucosamine-1-phosphate transferase, gamma subunit (GNPTG), heterogeneous nuclear ribonucleoprotein A1-like 2 (HNRNPA1), and insulin-like growth factor binding protein 2 (IGFBP2). Comprehensive sequential screening for autoantibodies reveals novel candidates for diagnostic markers in both seropositive and seronegative RA and suggests new fields of research into the pathogenesis of RA.
McDonough, Patrick L.; Jacobson, Richard H.; Timoney, John F.; Mutalib, Ahmed; Kradel, David C.; Chang, Yung-fu; Shin, Sang J.; Lein, Donald H.; Trock, Susan; Wheeler, Kaye
1998-01-01
Many regulatory and diagnostic programs for the detection of Salmonella enterica serotype Enteritidis infection in commercial poultry flocks have relied on rapid Pullorum agglutination tests to screen birds because of the shared antigens of S. enterica Enteritidis and S. enterica Pullorum and Gallinarum; however, the use of the enzyme-linked immunosorbent assay (ELISA) format affords better analytical sensitivity than crude agglutination tests. In this study, we adapted our earlier conventional indirect ELISA, using gm flagellin as the antigen, to a kinetics-based, computer-controlled ELISA (KELA). The KELA was used to screen for flagellin antibody from three commercial flocks: (i) a large flock involved in a U.S. Department of Agriculture trace back from a human S. enterica Enteritidis foodborne outbreak (n = 3,209), (ii) a flock infected with the endemic S. enterica Enteritidis serotype but which also had multiple other salmonella serotypes (n = 65), and (iii) an S. enterica Pullorum-infected flock (n = 12). The first flock (S. enterica Enteritidis prevalence of 2.45% based on culture) provided a field test of the KELA and allowed the calculation of diagnostic sensitivity (D-Sn) and diagnostic specificity (D-Sp). With a cutoff of 10 (used for screening flocks [i.e., high sensitivity]), the KELA has a D-Sn of 95.2% and a D-Sp of 18.5%; with a cutoff of 140 (used in confirmatory flock testing [i.e., high specificity]), the KELA has a D-Sn of 28.0% and a D-Sp of 99.1%. We found that with a cutoff of 60 (D-Sn = 63.1%; D-Sp = 91.6%), we could eliminate reactions in the KELA caused by other non-S. enterica Enteritidis salmonellae. The KELA was also compared to two commercial rapid Pullorum tests, the Solvay (D-Sn = 94.9%; D-Sp = 55.5%) and the Vineland (D-Sn = 62.0%; D-Sp = 75.3%). PMID:9665965
Cui, Zhaolei; Xiao, Zhenzhou; Hu, Minhua; Jiang, Chuanhui; Lin, Yingying; Chen, Yansong
2016-01-01
Background Epigenetic alterations of gene or DNA methylation have been highlighted as promising biomarkers for early cervical cancer screening. Herein, we evaluated the diagnostic performance of paired boxed gene 1 (PAX1) and sex determining region Y-box 1 (SOX1) methylation for cervical cancer detection. Methods Eligible studies were retrieved by searching the electronic databases. Study quality was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist. The bivariate meta-analysis model was employed to plot the summary receiver operator characteristic (SROC) curve using Stata 12.0 software. Results The pooled sensitivity of PAX1 methylation was estimated to be 0.73 [95% confidence interval (CI): 0.70–0.75] in differentiating patients with HSIL (high-grade squamous intraepithelial lesion) or CIN3+ (cervical intraepithelial neoplasia type III/worse) or cervical cancer from normal individuals, corresponding to a specificity of 0.87 (95% CI: 0.85–0.89) and area under the curve (AUC) of 0.91. The SOX1 methylation test yielded an AUC of 0.82, under which, the pooled sensitivity was 0.71 (95% CI: 0.67–0.74) and specificity was 0.64 (95% CI: 0.61–0.67). Notably, the stratified analysis suggested that combing parallel testing of PAX1 methylation and human papillomavirus (HPV) DNA (AUC, sensitivity, and specificity of 0.89, 0.75, and 0.81, respectively) achieved higher accuracy than single HPV DNA testing (AUC, sensitivity, and specificity of 0.77, 0.81, and 0.70, respectively). Conclusions PAX1 or SOX1 methylation has a prospect to be an auxiliary biomarker for cervical cancer screening, and parallel testing of PAX1 methylation and HPV DNA in cervical swabs confers an improved diagnostic accuracy than single HPV DNA testing. PMID:27826568
McDonough, P L; Jacobson, R H; Timoney, J F; Mutalib, A; Kradel, D C; Chang, Y F; Shin, S J; Lein, D H; Trock, S; Wheeler, K
1998-07-01
Many regulatory and diagnostic programs for the detection of Salmonella enterica serotype Enteritidis infection in commercial poultry flocks have relied on rapid Pullorum agglutination tests to screen birds because of the shared antigens of S. enterica Enteritidis and S. enterica Pullorum and Gallinarum; however, the use of the enzyme-linked immunosorbent assay (ELISA) format affords better analytical sensitivity than crude agglutination tests. In this study, we adapted our earlier conventional indirect ELISA, using gm flagellin as the antigen, to a kinetics-based, computer-controlled ELISA (KELA). The KELA was used to screen for flagellin antibody from three commercial flocks: (i) a large flock involved in a U.S. Department of Agriculture trace back from a human S. enterica Enteritidis foodborne outbreak (n = 3,209), (ii) a flock infected with the endemic S. enterica Enteritidis serotype but which also had multiple other Salmonella serotypes (n = 65), and (iii) an S. enterica Pullorum-infected flock (n = 12). The first flock (S. enterica Enteritidis prevalence of 2.45% based on culture) provided a field test of the KELA and allowed the calculation of diagnostic sensitivity (D-Sn) and diagnostic specificity (D-Sp). With a cutoff of 10 (used for screening flocks [i.e., high sensitivity]), the KELA has a D-Sn of 95.2% and a D-Sp of 18.5%; with a cutoff of 140 (used in confirmatory flock testing [i.e., high specificity]), the KELA has a D-Sn of 28.0% and a D-Sp of 99.1%. We found that with a cutoff of 60 (D-Sn = 63.1%; D-Sp = 91.6%), we could eliminate reactions in the KELA caused by other non-S. enterica Enteritidis salmonellae. The KELA was also compared to two commercial rapid Pullorum tests, the Solvay (D-Sn = 94.9%; D-Sp = 55.5%) and the Vineland (D-Sn = 62.0%; D-Sp = 75.3%).
Sermet-Gaudelus, Isabelle; Girodon, Emmanuelle; Roussel, Delphine; Deneuville, Eric; Bui, Stéphanie; Huet, Frédéric; Guillot, Marcel; Aboutaam, Rola; Renouil, Michel; Munck, Anne; des Georges, Marie; Iron, Albert; Thauvin-Robinet, Christel; Fajac, Isabelle; Lenoir, Gerard; Roussey, Michel; Edelman, Aleksander
2010-06-01
A challenging problem arising from cystic fibrosis (CF) newborn screening is the significant number of infants with hypertrypsinaemia (HIRT) with sweat chloride levels in the intermediate range and only one or no identified CF-causing mutations. To investigate the diagnostic value for CF of assessing CF transmembrane conductance regulator (CFTR) protein function by measuring nasal potential difference in children with HIRT. A specially designed protocol was used to assess nasal potential difference (NPD) in 23 young children with HIRT (3 months-4 years) with inconclusive neonatal screening. Results were analysed with a composite score including CFTR-dependent sodium and chloride secretion. Results were correlated with genotype after extensive genetic screening and with clinical phenotype at follow-up 3 years later. NPD was interpretable for 21 children with HIRT: 13 had NPD composite scores in the CF range. All 13 were finally found to carry two CFTR mutations. At follow-up, nine had developed a chronic pulmonary disease consistent with a CF diagnosis. The sweat test could be repeated in nine children, and six had sweat chloride values >or=60 mmol/l. Of the eight children with normal NPD scores, only two had two CFTR mutations, both wide-spectrum mutations. None had developed a CF-like lung disease at follow-up. The sweat test could be reassessed in five of these eight children and all had sweat chloride values <60 mmol/l. CF diagnosis was ruled out in six of these eight children. Evaluation of CFTR function in the nasal epithelium of young children with inconclusive results at CF newborn screening is a useful diagnostic tool for CF.
Antenatal screening and predicting hypertension in pregnancy for midwives.
Peacock, Ann S; Bogossian, Fiona
2010-09-01
The cause of hypertension in pregnancy remains unknown and results in increased risk of complications for mother and baby. Symptoms of developing pre-eclampsia, such as an elevated blood pressure, can be vague and singular. The purpose of this literature review is to evaluate research investigating antenatal screening practices for hypertension which fall within the midwives scope of practice. Inclusion criteria for this literature review were English language, peer reviewed primary research journal articles, published in the previous 20 years where the population under study was pregnant with reported outcomes of prevention, screening or prediction of hypertension in pregnancy. A large number of papers (n=201) were identified and these were screened and subsequently excluded if they addressed diagnostic testing, screening and interpretation that depended solely on a medical practitioner. There was no single predictive factor found, however the relevant papers included in this review (n=33) found evidence of modifiable, non-modifiable and clinical assessment factors for inclusion in a midwifery screening model. Further research should be focused on the factors observed by midwives during history taking and the antenatal course in the second and third trimesters and whether or not these can be synthesised in to a hypertension-specific diagnostic tool for use in midwifery practice. Copyright (c) 2009 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.
Plumb, Andrew A; Ghanouni, Alex; Rainbow, Sandra; Djedovic, Natasha; Marshall, Sarah; Stein, Judith; Taylor, Stuart A; Halligan, Steve; Lyratzopoulos, Georgios; von Wagner, Christian
2017-03-01
Background Screening participants with abnormal faecal occult blood test results who do not attend further testing are at high risk of colorectal cancer, yet little is known about their reasons for non-attendance. Methods We conducted a medical record review of 170 patients from two English Bowel Cancer Screening Programme centres who had abnormal guaiac faecal occult blood test screening tests between November 2011 and April 2013 but did not undergo colonoscopy. Using information from patient records, we coded and categorized reasons for non-attendance. Results Of the 170 patients, 82 were eligible for review, of whom 66 had at least one recorded reason for lack of colonoscopy follow-up. Reasons fell into seven main categories: (i) other commitments, (ii) unwillingness to have the test, (iii) a feeling that the faecal occult blood test result was a false positive, (iv) another health issue taking priority, (v) failing to complete bowel preparation, (vi) practical barriers (e.g. lack of transport), and (vii) having had or planning colonoscopy elsewhere. The most common single reasons were unwillingness to have a colonoscopy and being away. Conclusions We identify a range of apparent reasons for colonoscopy non-attendance after a positive faecal occult blood test screening. Education regarding the interpretation of guaiac faecal occult blood test findings, offer of alternative confirmatory test options, and flexibility in the timing or location of subsequent testing might decrease non-attendance of diagnostic testing following positive faecal occult blood test.
Floridia, Marco; Ciccacci, Fausto; Andreotti, Mauro; Hassane, Archa; Sidumo, Zita; Magid, Nurja A; Sotomane, Horacio; David, Muhlavasse; Mutemba, Elsa; Cebola, Junia; Mugunhe, Remigio Josè; Riccardi, Fabio; Marazzi, Maria Cristina; Giuliano, Marina; Palombi, Leonardo; Mancinelli, Sandro
2017-11-13
Tuberculosis is a major health concern in several countries, and effective diagnostic algorithms for use in human immunodeficiency virus (HIV)-positive patients are urgently needed. At prescription of antiretroviral therapy, all patients in 3 Mozambican health centers were screened for tuberculosis, with a combined approach: World Health Organization (WHO) 4-symptom screening (fever, cough, night sweats, and weight loss), a rapid test detecting mycobacterial lipoarabinomannan in urine (Determine TB LAM), and a molecular assay performed on a sputum sample (Xpert MTB/RIF; repeated if first result was negative). Patients with positive LAM or Xpert MTB/RIF results were referred for tuberculosis treatment. Among 972 patients with a complete diagnostic algorithm (58.5% female; median CD4 cell count, 278/μL; WHO HIV stage I, 66.8%), 98 (10.1%) tested positive with Xpert (90, 9.3%) or LAM (34, 3.5%) assays. Compared with a single-test Xpert strategy, dual Xpert tests improved case finding by 21.6%, LAM testing alone improved it by 13.5%, and dual Xpert tests plus LAM testing improved it by 32.4%. Rifampicin resistance in Xpert-positive patients was infrequent (2.5%). Among patients with positive results, 22 of 98 (22.4%) had no symptoms at WHO 4-symptom screening. Patients with tuberculosis diagnosed had significantly lower CD4 cell counts and hemoglobin levels, more advanced WHO stage, and higher HIV RNA levels. Fifteen (15.3%) did not start tuberculosis treatment, mostly owing to rapidly deteriorating clinical conditions or logistical constraints. The median interval between start of the diagnostic algorithm and start of tuberculosis treatment was 7 days. The prevalence of tuberculosis among Mozambican HIV-positive patients starting antiretroviral therapy was 10%, with limited rifampicin resistance. Use of combined point-of-care tests increased case finding, with a short time to treatment. Interventions are needed to remove logistical barriers and prevent presentation in very advanced HIV/tuberculosis disease. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
A systematic review of the PTSD Checklist's diagnostic accuracy studies using QUADAS.
McDonald, Scott D; Brown, Whitney L; Benesek, John P; Calhoun, Patrick S
2015-09-01
Despite the popularity of the PTSD Checklist (PCL) as a clinical screening test, there has been no comprehensive quality review of studies evaluating its diagnostic accuracy. A systematic quality assessment of 22 diagnostic accuracy studies of the English-language PCL using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) assessment tool was conducted to examine (a) the quality of diagnostic accuracy studies of the PCL, and (b) whether quality has improved since the 2003 STAndards for the Reporting of Diagnostic accuracy studies (STARD) initiative regarding reporting guidelines for diagnostic accuracy studies. Three raters independently applied the QUADAS tool to each study, and a consensus among the 4 authors is reported. Findings indicated that although studies generally met standards in several quality areas, there is still room for improvement. Areas for improvement include establishing representativeness, adequately describing clinical and demographic characteristics of the sample, and presenting better descriptions of important aspects of test and reference standard execution. Only 2 studies met each of the 14 quality criteria. In addition, study quality has not appreciably improved since the publication of the STARD Statement in 2003. Recommendations for the improvement of diagnostic accuracy studies of the PCL are discussed. (c) 2015 APA, all rights reserved).
Levin, Carol E; Sellors, John; Shi, Ju-Fang; Ma, Li; Qiao, You-lin; Ortendahl, Jesse; O'Shea, Meredith K H; Goldie, Sue J
2010-09-01
This study assessed the cost-effectiveness of a new, rapid human papillomavirus (HPV)-DNA screening test for cervical cancer prevention in the high-risk region of Shanxi, China. Using micro-costing methods, we estimated the resources needed to implement preventive strategies using cervical cytology or HPV-DNA testing, including the Hybrid Capture 2 (hc2) test (QIAGEN Corp., Gaithersburg, MD) and the rapid HPV-DNA careHPV test (QIAGEN). Data were used in a previously published model and empirically calibrated to country-specific epidemiological data. Strategies differed by initial test, targeted age, frequency of screening, number of clinic visits required (1, 2 or 3) and service delivery setting (national, county and township levels). Outcomes included lifetime risk of cancer, years of life saved (YLS), lifetime costs and incremental cost-effectiveness ratios (cost per YLS). For all screening frequencies, the most efficient strategy used 2-visit rapid HPV-DNA testing at the county level, including screening and diagnostics in the first visit, and treatment in the second visit. Screening at ages 35, 40 and 45 reduced cancer risk by 50% among women compliant with all 3 screening rounds, and was US$ 150 per YLS, compared with this same strategy applied twice per lifetime. This would be considered very cost-effective evaluated against China's per-capita gross domestic product (US$ 1,702). By enhancing the linkage between screening and treatment through a reduced number of visits, rapid HPV-DNA testing 3 times per lifetime is more effective than traditional cytology, and is likely to be cost-effective in high-risk regions of China.
Cantor, Amy G; Pappas, Miranda; Daeges, Monica; Nelson, Heidi D
2016-06-07
Screening for syphilis infection is currently recommended for high-risk individuals, including those with previous syphilis infection, an infected sexual partner, HIV infection, or more than 4 sex partners in the preceding year. To update a 2004 systematic review of studies of syphilis screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews through October 2015 and Ovid MEDLINE (January 2004 to October 2015), with updated search through March 2016. English-language trials and observational studies of screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. One investigator abstracted data, a second checked data for accuracy, and 2 investigators independently assessed study quality using predefined criteria. Transmission of disease, including HIV; complications of syphilis; diagnostic accuracy; and harms of screening. No evidence was identified regarding the effectiveness of screening on clinical outcomes or the effectiveness of risk assessment instruments; the harms of screening; or the effectiveness of screening in average-risk, nonpregnant adolescents or adults or high-risk individuals other than men who have sex with men (MSM) or men who are HIV positive. Four non-US studies indicated higher rates of syphilis detection with screening every 3 months vs 6 or 12 months for early syphilis in HIV-positive men or MSM. For example, there was an increased proportion of asymptomatic, higher-risk MSM in Australia (n = 6789 consultations) receiving a diagnosis of early syphilis when tested every 3 months vs annually (53% vs 16%, P = .001), but no difference among low-risk MSM. Treponemal and nontreponemal tests were accurate in asymptomatic individuals (sensitivity >85%, specificity >91%) in 3 studies but required confirmatory testing. Reverse sequence testing with an initial automated treponemal test yielded more false reactive test results than with rapid plasma reagin in 2 studies, one with a low-prevalence US population (0.6% vs 0.0%, P = .03) and another in a higher-prevalence Canadian population (0.26% vs 0.13%). Screening HIV-positive men or MSM for syphilis every 3 months is associated with improved syphilis detection. Treponemal or nontreponemal tests are accurate screening tests but require confirmation. Research is needed on the effect of screening on clinical outcomes; effective screening strategies, including reverse sequence screening, in various patient populations; and harms of screening.
Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno
2012-07-09
Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.
Fenske, Wiebke; Allolio, Bruno
2012-10-01
The differential diagnosis of diabetes insipidus (DI) is often challenging but essential, because treatment may vary substantially. This article analyzes the database and performance of currently used differential diagnostic tests for DI and discusses future perspectives for diagnostic improvement. A review of electronic and print data comprising original and review articles retrieved from the PubMed or Cochrane Library database up to January 2012 was conducted. The search term "polyuria polydipsia syndrome" was cross-referenced with underlying forms of disease and associated clinical, diagnostic, and therapeutic MeSH terms. In addition, references from review articles and textbook chapters were screened for papers containing original data. Search results were narrowed to articles containing primary data with a description of criteria for the differential diagnosis of DI. Fifteen articles on differential diagnosis of DI were identified, mainly consisting of small series of patients, and mostly covering only part of the differential diagnostic spectrum of DI. Test protocols differed, and prospective validation of diagnostic criteria was consistently missing. Inconsistent data were reported on the diagnostic superiority of direct plasma arginine vasopressin determination over the indirect water deprivation test. Both test methods revealed limitations, especially in the differentiation of disorders with a milder phenotype. The available data demonstrate limitations of current biochemical tests for the differential diagnosis of DI, potentially leading to incorrect diagnosis and treatment. The newly available assay for copeptin, the C terminus of the vasopressin precursor, holds promise for a higher diagnostic specificity and simplification of the differential diagnostic protocol in DI.
Hewetson, Michael; Sykes, Ben William; Hallowell, Gayle Davina; Tulamo, Riitta-Mari
2017-03-11
Equine gastric ulcer syndrome (EGUS) is common in adult horses, particularly those involved in performance disciplines. Currently, detection of EGUS by gastroscopy is the only reliable ante mortem method for definitive diagnosis; however it is unsuitable as a screening test because it is expensive, time consuming, and is not readily available to most veterinarians. Sucrose permeability testing represents a simple, economical alternative to gastroscopy for screening purposes, and the feasibility of this approach in the horse has been previously reported. The aim of this study was to determine the diagnostic accuracy of blood sucrose as a screening test for EGUS in a large group of adult horses with and without naturally occurring gastric disease. One hundred and one adult horses with or without naturally occurring gastric ulceration were studied. The diagnostic accuracy of blood sucrose for diagnosis of gastric lesions (GL), glandular lesions (GDL), squamous lesions (SQL), and clinically significant lesions (CSL) at 45 and 90 min after administration of 1 g/kg of sucrose via nasogastric intubation was assessed using receiver operator characteristics (ROC) curves and calculating the area under the curve (AUC). For each lesion type, sucrose concentration in blood was compared to gastroscopy, as the gold standard, and sensitivities (Se) and specificities (Sp) were calculated across a range of sucrose concentrations. Ulcer grading was performed blindly by one observer; and the results were validated by comparing them with that of two other observers, and calculating the level of agreement. Cut-off values were selected manually to optimize Se. The prevalence of GL, GDL, SQL, and CSL was 83, 70, 53 and 58% respectively. At the selected cut-offs, Se ranged from 51 to 79% and Sp ranged from 43 to 72%, depending upon the lesion type and time of sampling. Blood sucrose is neither a sensitive or specific test for detecting EGUS in this population of adult horses with naturally occurring gastric ulceration. Further studies aimed at evaluating the performance characteristics of the test in different study populations are warranted. Given the limitations of endoscopy, due consideration should also be given to alternative methods for comparison of blood sucrose with a gold standard.
Pereira, Gilberto de Araujo; Louzada-Neto, Francisco; Barbosa, Valdirene de Fátima; Ferreira-Silva, Márcia Maria; de Moraes-Souza, Helio
2012-01-01
The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.
[Ethical aspects of disclosing information on prenatal screening for Down's syndrome].
Tóth, Adél; Szabó, János
2005-02-06
Giving detailed information on prenatal screening for Down's syndrome is considered as paramount since this medical procedure intends to enhance the patient's self-governance in reproductive issues. Not only the respect for autonomy, but also the increased maternal anxiety and the reproductive decisions following the positive test result demand from the genetic professional to offer the test through genetic counselling. The counsellor's awareness about the expectations of pregnant women and the clarification of her own attitude concerning the screening can contribute to the effectiveness of counselling. The content of information embraces the technical aspects of screening and its consequences, like the description of Down's syndrome, the method of screening, the way of risk assessment, the detection rate, the false positive and false negative test results, the diagnostic procedures, and the termination of pregnancy. Written information leaflets should be completed by personal communication as the combination of these two forms has proved to be the most useful. The process of consultation is influenced by the communication skill of the genetic professional and the information seeking activity of the patient, so doctors should be trained to communicate better and patients should be encouraged to get more information about the screening.
Cushing's syndrome: Stepwise approach to diagnosis
Lila, Anurag R.; Sarathi, Vijaya; Jagtap, Varsha S.; Bandgar, Tushar; Menon, Padmavathy; Shah, Nalini S.
2011-01-01
The projected prevalence of Cushing's syndrome (CS) inclusive of subclinical cases in the adult population ranges from 0.2–2% and it may no longer be considered as an orphan disease (2–3 cases/million/year). The recognition of CS by physicians is important for early diagnosis and treatment. Late-night salivary cortisol, dexamethasone suppressiontesti, or 24-h urine free cortisol are good screening tests. Positively screened cases need stepwise evaluation by an endocrinologist. This paper discusses the importance of screening for CS and suggests a stepwise diagnostic approach to a case of suspected hypercortisolism. PMID:22145134
Markowicz, Mateusz; Grilnberger, Evelyn; Huber, Florian; Leibl, Gabriele; Abrahamian, Heidemarie; Gartner, Manfred; Huber, Monika; Chott, Andreas; Reiter, Michael; Stanek, Gerold
2013-08-01
Proctitis caused by Chlamydia trachomatis L2b can manifest with very mild, nonspecific symptoms, and appropriate diagnostic evaluation is crucial. The case report demonstrates that rapid screening test, detection of specific antibodies in serum, and direct pathogen identification by PCR performed on tissue sample or rectal swab allow successful diagnosis of the still emerging sexually transmitted disease among homosexual patients. Copyright © 2013 Elsevier Inc. All rights reserved.
[Faecal occult blood test for colorectal cancer screening: high quality for a good price].
van Veldhuizen, Harriët; Bonfrer, J M G Hans; Kuipers, Ernst J
2013-01-01
The Dutch National Institute for Public Health and the Environment (RIVM) awarded the immunochemical faecal occult blood test (IFOBT) to FOB Gold of Sentinel following a European call for tenders. The contract-awarding procedure included the application of quality knock-out criteria, which were met by two suppliers. The decisive factor was the best price/quality ratio. A recent review indicated that, at present, no single IFOBT is better than any other. The decision to opt for a test manufactured by a different supplier than was used in the previous screening pilots made it necessary to re-determine the cut-off value. This value has now been set (88 ng/ml) and is confirmed by a laboratory test. Colonoscopy-related capacity planning, as well as its diagnostic yield, depends on numerous factors; therefore, the RIVM is currently monitoring the referral percentage and number of adenomas detected and is collaborating on quality terms. Any necessary adjustments are to be made during the introduction of the screening test.
Diagnostic Methods for Platelet Bacteria Screening: Current Status and Developments
Störmer, Melanie; Vollmer, Tanja
2014-01-01
Summary Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes. PMID:24659944
Web-based mammography audit feedback.
Geller, Berta M; Ichikawa, Laura; Miglioretti, Diana L; Eastman, David
2012-06-01
Interpreting screening mammography accurately is challenging and requires ongoing education to maintain and improve interpretative skills. Recognizing this, many countries with organized breast screening programs have developed audit and feedback systems using national performance data to help radiologists assess and improve their skills. We developed and tested an interactive Website to provide screening and diagnostic mammography audit feedback with comparisons to national and regional benchmarks. Radiologists who participate in three Breast Cancer Surveillance Consortium registries in the United States were invited during 2009 and 2010 to use a Website that provides tabular and graphical displays of mammography audit reports with comparisons to national and regional performance measures. We collected data about the use and perceptions of the Website. Thirty-five of 111 invited radiologists used the Website from one to five times in a year. The most popular measure was sensitivity for both screening and diagnostic mammography, whereas a table with all measures was the most visited page. Of the 13 radiologists who completed the postuse survey, all found the Website easy to use and navigate, 11 found the benchmarks useful, and nine reported that they intended to improve a specific outcome measure that year. An interactive Website to provide customized mammography audit feedback reports to radiologists has the potential to be a powerful tool in improving interpretive performance. The conceptual framework of customized audit feedback reports can also be generalized to other imaging tests.
Ghosh, Chiranjit; Maity, Abhijit; Banik, Gourab D; Som, Suman; Chakraborty, Arpita; Selvan, Chitra; Ghosh, Shibendu; Ghosh, Barnali; Chowdhury, Subhankar; Pradhan, Manik
2014-09-01
We report, for the first time, the clinical feasibility of a novel residual gas analyzer mass spectrometry (RGA-MS) method for accurate evaluation of the (13)C-glucose breath test ((13)C-GBT) in the diagnosis of pre-diabetes (PD) and type 2 diabetes mellitus (T2D). In T2D or PD, glucose uptake is impaired and results in blunted isotope enriched (13)CO2 production in exhaled breath samples. Using the Receiver operating characteristics (ROC) curve analysis, an optimal diagnostic cut-off point of the (13)CO2/(12)CO2 isotope ratios expressed as the delta-over-baseline (DOB) value, was determined to be δDOB(13)C‰ = 28.81‰ for screening individuals with non-diabetes controls (NDC) and pre-diabetes (PD), corresponding to a sensitivity of 100% and specificity of 94.4%. We also determined another optimal diagnostic cut-off point of δDOB(13)C‰ = 19.88‰ between individuals with PD and T2D, which exhibited 100% sensitivity and 95.5% specificity. Our RGA-MS methodology for the (13)C-GBT also manifested a typical diagnostic positive and negative predictive value of 96% and 100%, respectively. The diagnostic accuracy, precision and validity of the results were also confirmed by high-resolution optical cavity enhanced integrated cavity output spectroscopy (ICOS) measurements. The δDOB(13)C‰ values measured with RGA-MS method, correlated favourably (R(2) = 0.979) with those determined by the laser based ICOS method. Moreover, we observed that the effects of endogenous CO2 production related to basal metabolic rates in individuals were statistically insignificant (p = 0.37 and 0.73) on the diagnostic accuracy. Our findings suggest that the RGA-MS is a valid and sufficiently robust method for the (13)C-GBT which may serve as an alternative non-invasive point-of-care diagnostic tool for routine clinical practices as well as for large-scale diabetes screening purposes in real-time.
Relativity Screens for Misvalued Medical Services: Impact on Noninvasive Diagnostic Radiology.
Rosenkrantz, Andrew B; Silva, Ezequiel; Hawkins, C Matthew
2017-11-01
In 2006, the AMA/Specialty Society Relative Value Scale Update Committee (RUC) introduced ongoing relativity screens to identify potentially misvalued medical services for payment adjustments. We assess the impact of these screens upon the valuation of noninvasive diagnostic radiology services. Data regarding relativity screens and relative value unit (RVU) changes were obtained from the 2016 AMA Relativity Assessment Status Report. All global codes in the 2016 Medicare Physician Fee Schedule with associated work RVUs were classified as noninvasive diagnostic radiology services versus remaining services. The frequency of having ever undergone a screen was compared between the two groups. Screened radiology codes were further evaluated regarding the RVU impact of subsequent revaluation. Of noninvasive diagnostic radiology codes, 46.0% (201 of 437) were screened versus 22.2% (1,460 of 6,575) of remaining codes (P < .001). Most common screens for which radiology codes were identified as potentially misvalued were (1) high expenditures (27.5%) and (2) high utilization (25.6%). The modality and body region most likely to be identified in a screen were CT (82.1%) and breast (90.9%), respectively. Among screened radiology codes, work RVUs, practice expense RVUs, and nonfacility total RVUs decreased in 20.3%, 65.9%, and 75.3%, respectively. All screened CT, MRI, brain, and spine codes exhibited decreased total RVUs. Policymakers' ongoing search for potentially misvalued medical services has disproportionately impacted noninvasive diagnostic radiology services, risking the introduction of unintended or artificial shifts in physician practice. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Lorincz, Attila; Raison, Claire
2015-01-01
Interview with Attila Lorincz by Claire Raison (Commissioning Editor) To mark the beginning of the 15th year of Expert Review of Molecular Diagnostics, the journal's Editor-in-Chief shares his expert knowledge on translational diagnostics, his opinion on recent controversies and his predictions for molecular diagnostics in 2015 and beyond. Attila Lorincz received his doctorate from Trinity College, Dublin, Republic of Ireland, and went on to become a research fellow at the University of California, Santa Barbara, CA, USA. During Professor Lorincz's research on human papillomavirus (HPV), he found several important and novel carcinogenic HPV types and pioneered the use of HPV DNA testing for clinical diagnostics. In 1988, Professor Lorincz's team produced the first HPV test to be FDA-approved for patients and in 2003, for general population cervical precancer screening. Now Professor of Molecular Epidemiology at the Centre for Cancer Prevention, Queen Mary University of London, UK, he and his team are furthering translational research into DNA methylation assays for cancer risk prediction.
Biasutti, Maria; Dufour, Natacha; Ferroud, Clotilde; Dab, William; Temime, Laura
2012-01-01
Used as contrast agents for brain magnetic resonance imaging (MRI), markers for beta-amyloid deposits might allow early diagnosis of Alzheimer's disease (AD). We evaluated the cost-effectiveness of such a diagnostic test, MRI+CLP (contrastophore-linker-pharmacophore), should it become clinically available. We compared the cost-effectiveness of MRI+CLP to that of standard diagnosis using currently available cognition tests and of standard MRI, and investigated the impact of a hypothetical treatment efficient in early AD. The primary analysis was based on the current French context for 70-year-old patients with Mild Cognitive Impairment (MCI). In alternative "screen and treat" scenarios, we analyzed the consequences of systematic screenings of over-60 individuals (either population-wide or restricted to the ApoE4 genotype population). We used a Markov model of AD progression; model parameters, as well as incurred costs and quality-of-life weights in France were taken from the literature. We performed univariate and probabilistic multivariate sensitivity analyses. The base-case preferred strategy was the standard MRI diagnosis strategy. In the primary analysis however, MRI+CLP could become the preferred strategy under a wide array of scenarios involving lower cost and/or higher sensitivity or specificity. By contrast, in the "screen and treat" analyses, the probability of MRI+CLP becoming the preferred strategy remained lower than 5%. It is thought that anti-beta-amyloid compounds might halt the development of dementia in early stage patients. This study suggests that, even should such treatments become available, systematically screening the over-60 population for AD would only become cost-effective with highly specific tests able to diagnose early stages of the disease. However, offering a new diagnostic test based on beta-amyloid markers to elderly patients with MCI might prove cost-effective.
Willingness to pay for diagnostic technologies: a review of the contingent valuation literature.
Lin, Pei-Jung; Cangelosi, Michael J; Lee, David W; Neumann, Peter J
2013-01-01
To understand how people value information from diagnostic technologies, we reviewed and analyzed published willingness-to-pay (WTP) studies on the topic. We searched PubMed for English-language articles related to WTP for diagnostic laboratory tests published from 1985 through 2011. We characterized methodological differences across studies, examined individual- and technology-level factors associated with WTP, and summarized median WTP values across different diagnostic tests. We identified 66 relevant WTP studies. Half focused on oncology, while others analyzed infectious diseases (n = 11, 16.1%) and obstetric or gynecological conditions (n = 8, 11.7%), among others. Most laboratory tests included in studies were biological samples/genetic testing (n = 44, 61.1%) or imaging tests (n = 23, 31.9%). Approximately one third of the analyses (n = 20, 30.3%) used discrete-choice questions to elicit WTP values. Higher income, education, disease severity, perceived disease risk, family history, and more accurate tests were in general associated with higher WTP values for diagnostic information. Of the 44 studies with median WTP values available, most reported a median WTP value below $100. The median WTP value for colon or colorectal cancer screening ranged from below $100 to over $1000. The contingent valuation literature in diagnostics has grown rapidly, and suggests that many respondents place considerable value on diagnostic information. There exists, however, great variation in studies with respect to the type of technologies and diseases assessed, respondent characteristics, and study methodology. The perceived value of diagnostic technologies is also influenced by the study design and elicitation methods. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
A Comparison of Methods to Screen Middle School Students for Reading and Math Difficulties
ERIC Educational Resources Information Center
Nelson, Peter M.; Van Norman, Ethan R.; Lackner, Stacey K.
2016-01-01
The current study explored multiple ways in which middle schools can use and integrate data sources to predict proficiency on future high-stakes state achievement tests. The diagnostic accuracy of (a) prior achievement data, (b) teacher rating scale scores, (c) a composite score combining state test scores and rating scale responses, and (d) two…
[Evaluation of peruvian money test in screening of cognitive impairment among older adults].
Oscanoa, Teodoro J; Cieza, Edwin; Parodi, José F; Paredes, Napoleón
2016-03-01
Objectives To evaluate the Peruvian adaptation of the money test (Eurotest) for identifying cognitive impairment among >60-year-old adults. Materials and methods This is a phase I study of diagnostic test, with a convenience sampling and calculation of the test´s sensitivity and specificity, based on a pretest prevalence of 50%. The criteria of the Diagnostic and Statistical Manual of Mental Disorders (DSM IV) and Global Deterioration Scale (GDS) were used for the operational definition of patients with cognitive impairment. Receiver operating characteristic (ROC) curve analysis was used to identify the optimal cut-off value. Results The study evaluated 42 cases and 42 controls; there was no significant difference between age (77.88 ± 6.01 years vs. 6.49 76.14 ± years) and years of education (13.69 ± 3.70 years vs. 8.17 ± 4.71 years). The Peruvian version of the Eurotest has a sensitivity of 90.5% and specificity of 83.3% with cut-off value of 24. Conclusions The Peruvian adapted version of the Eurotest, called prueba de la moneda peruana could be useful in screening for cognitive impairment among older adults.
Rogé, Stijn; Van Nieuwenhove, Liesbeth; Meul, Magali; Heykers, Annick; Brouwer de Koning, Annette; Bebronne, Nicolas; Guisez, Yves; Büscher, Philippe
2014-07-01
Screening tests for gambiense sleeping sickness, such as the CATT/T. b. gambiense and a recently developed lateral flow tests, are hitherto based on native variant surface glycoproteins (VSGs), namely LiTat 1.3 and LiTat 1.5, purified from highly virulent trypanosome strains grown in rodents. We have expressed SUMO (small ubiquitin-like modifier) fusion proteins of the immunogenic N-terminal part of these antigens in the yeast Pichia pastoris. The secreted recombinant proteins were affinity purified with yields up to 10 mg per liter cell culture. The diagnostic potential of each separate antigen and a mixture of both antigens was confirmed in ELISA on sera from 88 HAT patients and 74 endemic non-HAT controls. Replacement of native antigens in the screening tests for sleeping sickness by recombinant proteins will eliminate both the infection risk for the laboratory staff during antigen production and the need for laboratory animals. Upscaling production of recombinant antigens, e.g. in biofermentors, is straightforward thus leading to improved standardisation of antigen production and reduced production costs, which on their turn will increase the availability and affordability of the diagnostic tests needed for the elimination of gambiense HAT.
Krill, Michael K; Rosas, Samuel; Kwon, KiHyun; Dakkak, Andrew; Nwachukwu, Benedict U; McCormick, Frank
2018-02-01
The clinical examination of the shoulder joint is an undervalued diagnostic tool for evaluating acromioclavicular (AC) joint pathology. Applying evidence-based clinical tests enables providers to make an accurate diagnosis and minimize costly imaging procedures and potential delays in care. The purpose of this study was to create a decision tree analysis enabling simple and accurate diagnosis of AC joint pathology. A systematic review of the Medline, Ovid and Cochrane Review databases was performed to identify level one and two diagnostic studies evaluating clinical tests for AC joint pathology. Individual test characteristics were combined in series and in parallel to improve sensitivities and specificities. A secondary analysis utilized subjective pre-test probabilities to create a clinical decision tree algorithm with post-test probabilities. The optimal special test combination to screen and confirm AC joint pathology combined Paxinos sign and O'Brien's Test, with a specificity of 95.8% when performed in series; whereas, Paxinos sign and Hawkins-Kennedy Test demonstrated a sensitivity of 93.7% when performed in parallel. Paxinos sign and O'Brien's Test demonstrated the greatest positive likelihood ratio (2.71); whereas, Paxinos sign and Hawkins-Kennedy Test reported the lowest negative likelihood ratio (0.35). No combination of special tests performed in series or in parallel creates more than a small impact on post-test probabilities to screen or confirm AC joint pathology. Paxinos sign and O'Brien's Test is the only special test combination that has a small and sometimes important impact when used both in series and in parallel. Physical examination testing is not beneficial for diagnosis of AC joint pathology when pretest probability is unequivocal. In these instances, it is of benefit to proceed with procedural tests to evaluate AC joint pathology. Ultrasound-guided corticosteroid injections are diagnostic and therapeutic. An ultrasound-guided AC joint corticosteroid injection may be an appropriate new standard for treatment and surgical decision-making. II - Systematic Review.
Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy.
Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum
2017-01-01
The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Retrospective study. Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% ( P < 0.0001); specificity, 98.53% and 86.76% ( P = 0.0026); accuracy, 77.04% and 85.93% ( P = 0.0423), respectively. The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test.
2012-01-01
Background Both treatment and prevention strategies are recommended by the World Health Organization for the control of malaria during pregnancy in tropical areas. The aim of this study was to assess use of a rapid diagnostic test for prompt management of malaria in pregnancy in Bangui, Central African Republic. Methods A cohort of 76 pregnant women was screened systematically for malaria with ParacheckPf® at each antenatal visit. The usefulness of the method was analysed by comparing the number of malaria episodes requiring treatment in the cohort with the number of prescriptions received by another group of pregnant women followed-up in routine antenatal care. Results In the cohort group, the proportion of positive ParacheckPf® episodes during antenatal clinics visits was 13.8%, while episodes of antimalarial prescriptions in the group which was followed-up routinely by antenatal personnel was estimated at 26.3%. Hence, the relative risk of the cohort for being prescribed an antimalarial drug was 0.53. Therefore, the attributable fraction of presumptive treatment avoided by systematic screening with ParacheckPf® was 47%. Conclusions Use of a rapid diagnostic test is useful, affordable and easy for adequate treatment of malaria in pregnant women. More powerful studies of the usefulness of introducing the test into antenatal care are needed in all heath centres in the country and in other tropical areas. PMID:22734602
JAK2 mutations and clinical practice in myeloproliferative neoplasms.
Tefferi, Ayalew
2007-01-01
With the discovery in the last 3 years of novel Janus kinase 2 (JAK2) and thrombopoietin receptor (MPL) mutations, the pathogenetic understanding of and clinical practice for myeloproliferative neoplasms (MPNs) have entered a new era. Each one of these newly discovered mutations, including JAK2V617F, MPLW515L, and a JAK2 exon 12 mutation, has been shown to result in constitutive activation of JAK-STAT signaling and also induce a MPN phenotype in mice. Thus, JAK2 is now considered to be a legitimate target for drug development in MPNs, and small molecule JAK2 inhibitors have already gone through successful preclinical testing, and early-phase human trials in primary myelofibrosis have already begun. Furthermore, JAK2 mutation screening has now become a front-line diagnostic test in the evaluation of both "erythrocytosis" and thrombocytosis and the 2001 World Health Organization diagnostic criteria for polycythemia vera, essential thrombocythemia, and primary myelofibrosis have now been revised to incorporate JAK2V617F mutation screening.
Metabolic emergencies and the emergency physician.
Fletcher, Janice Mary
2016-02-01
Fifty percent of inborn errors of metabolism are present in later childhood and adulthood, with crises commonly precipitated by minor viral illnesses or increased protein ingestion. Many physicians only consider IEM after more common conditions (such as sepsis) have been considered. In view of the large number of inborn errors, it might appear that their diagnosis requires precise knowledge of a large number of biochemical pathways and their interrelationship. As a matter of fact, an adequate diagnostic approach can be based on the proper use of only a few screening tests. A detailed history of antecedent events, together with these simple screening tests, can be diagnostic, leading to life-saving, targeted treatments for many disorders. Unrecognised, IEM can lead to significant mortality and morbidity. Advice is available 24/7 through the metabolic service based at the major paediatric hospital in each state and Starship Children's Health in New Zealand. © 2016 The Author. Journal of Paediatrics and Child Health © 2016 Paediatrics and Child Health Division (Royal Australasian College of Physicians).
Freund, Romain; Granger, Benjamin; Francois, Cécile; Carcelain, Guislaine; Ravaud, Philippe; Mariette, Xavier; Fautrel, Bruno
2018-02-01
Several tests have been proposed to detect latent tuberculosis (LTB). To evaluate the cost-effectiveness of different interferon-gamma release assays based strategies used to screen LTB before tumour necrosis factor (TNF) blockers initiation. Consecutive patients with rheumatoid arthritis, spondyloarthritis or Crohn's disease for whom TNF-blockers were considered, were recruited in 15 tertiary care centres. All were screened for LTB with tuberculin skin test (TST), QuantiFERON TB Gold ® in tube (QFT) and T-SPOT.TB ® (TSpot) on the same day. Cost-minimization and cost-effectiveness analysis, testing 8 screening test combinations, were conducted. Effectiveness was defined as the percentage of LTB treatment avoided and compared with TST alone. Cost were elicited in the payer perspective, included all the costs related to the screening procedure. No tuberculosis reactivation was observed after TNF-blocker initiation. TST followed by QFT if TST was positive was found as the best screening strategy, i.e. the less costly (-54€ compared to reference) and most effective (effectiveness 0.93), resulting in an incremental cost-effectiveness ratio of -192€ per treatment avoided. A probabilistic sensitivity analysis confirmed this result in 72.3% of simulations. TST followed by QFT if TST was positive is the most cost-effective strategy in screening for LTB in patients before starting anti-TNF therapy. NCT00811343. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Niimi, Hideki; Ogawa, Tomomi; Note, Rhougou; Hayashi, Shirou; Ueno, Tomohiro; Harada, Kenu; Uji, Yoshinori; Kitajima, Isao
2010-12-01
In recent years, genetic diagnostics of pathogenic splicing abnormalities are increasingly recognized as critically important in the clinical genetic diagnostics. It is reported that approximately 10% of pathogenic mutations causing human inherited diseases are splicing mutations. Nonetheless, it is still difficult to identify splicing abnormalities in routine genetic diagnostic settings. Here, we studied two different kinds of cases with splicing abnormalities. The first case is a protein S deficiency. Nucleotide analyses revealed that the proband had a previously reported G to C substitution in the invariant AG dinucleotide at the splicing acceptor site of intronl/exon2, which produces multiple splicing abnormalities resulting in protein S deficiency. The second case is an antithrombin (AT) deficiency. This proband had a previously reported G to A substitution, at nucleotide position 9788 in intron 4, 14 bp in front of exon 5, which created a de novo exon 5 splice site and resulted in AT deficiency. From a practical standpoint, we discussed the pitfalls, attentions, and screening approaches in genetic diagnostics of pathogenic splicing abnormalities. Due to the difficulty with full-length sequence analysis of introns, and the lack of RNA samples, splicing mutations may escape identification. Although current genetic testing remains to be improved, to screen for splicing abnormalities more efficiently, it is significant to use an appropriate combination of various approaches such as DNA and/or RNA samples, splicing mutation databases, bioinformatic tools to detect splice sites and cis-regulatory elements, and in vitro and/or in vivo experimentally methods as needed.
Evaluation of the LDBIO point of care test for the combined detection of toxoplasmic IgG and IgM.
Chapey, Emmanuelle; Wallon, Martine; Peyron, François
2017-01-01
The toxoplasma ICT IgG-IgM rapid diagnostic test for the simultaneous detection of specific toxoplasmic immunoglobulin (Ig) G and IgM was compared with the Architect fully automated chemiluminescence test. Four hundred sera were included, among which 248 scored negative in Architect. The cassettes were easily read with the naked eye. Diagnostic sensitivity and specificity were 97% and 96%, respectively. The test scored 8 false-positive IgG and yielded negative results in 3 sera displaying unspecific IgM in Architect. The LDBIO appears to be a reliable first line test, although the false-positive results for IgG deserve further investigation. Such an easily performed test could be used advantageously for screening for toxoplasmosis in pregnant women. Copyright © 2016 Elsevier B.V. All rights reserved.
Kitchen, A D; Lowe, P H J; Lalloo, K; Chiodini, P L
2004-10-01
A new recombinant Plasmodium antigen enzyme immunoassay (EIA) for the detection of malarial antibodies was evaluated for the screening of 'malaria-risk' blood and tissue donations. A total of 13,269 donor and patient samples were tested by both the EIA and the standard diagnostic antibody immunofluorescence test (IFAT). A total of 114/138 (82.6%) samples from patients with P. falciparum and 11/13 (84.6%) samples from patients with P. vivax tested positive. A total of 714/13,053 (5.47%) samples from donors identified as 'malaria risk', owing to residency or travel, were reactive in the EIA. The assay is more sensitive than a previously implemented malarial antibody EIA (73% in acute P. falciparum and 56% in acute P. vivax infections). The sensitivity of this new EIA is comparable to that of the IFAT, and the specificity is sufficient to screen 'malaria-risk' donors.
Mens, Petra F; Matelon, Raphael J; Nour, Bakri Y M; Newman, Dave M; Schallig, Henk D F H
2010-07-19
This study describes the laboratory evaluation of a novel diagnostic platform for malaria. The Magneto Optical Test (MOT) is based on the bio-physical detection of haemozoin in clinical samples. Having an assay time of around one minute, it offers the potential of high throughput screening. Blood samples of confirmed malaria patients from different regions of Africa, patients with other diseases and healthy non-endemic controls were used in the present study. The samples were analysed with two reference tests, i.e. an histidine rich protein-2 based rapid diagnostic test (RDT) and a conventional Pan-Plasmodium PCR, and the MOT as index test. Data were entered in 2 x 2 tables and analysed for sensitivity and specificity. The agreement between microscopy, RDT and PCR and the MOT assay was determined by calculating Kappa values with a 95% confidence interval. The observed sensitivity/specificity of the MOT test in comparison with clinical description, RDT or PCR ranged from 77.2 - 78.8% (sensitivity) and from 72.5 - 74.6% (specificity). In general, the agreement between MOT and the other assays is around 0.5 indicating a moderate agreement between the reference and the index test. However, when RDT and PCR are compared to each other, an almost perfect agreement can be observed (k = 0.97) with a sensitivity and specificity of >95%. Although MOT sensitivity and specificity are currently not yet at a competing level compared to other diagnostic test, such as PCR and RDTs, it has a potential to rapidly screen patients for malaria in endemic as well as non-endemic countries.
Hirtzlin, I; Fagot-Campagna, A; Girard-Le Gallo, I; Vallier, N; Poutignat, N; Weill, A; Le Laidier, S
2004-04-01
Type 2 diabetes mellitus may go undiagnosed for several Years while complications are silently developing. In France, from 2 to 3.7% of adults aged 35-65 are unaware they have diabetes. Nevertheless fasting serum glucose is a simple diagnostic test. We described people who underwent opportunist diabetes screening (serum glucose) within 2 Years (2000-2001). We used the administrative EPAS cohort from the employee National Health Insurance System which covers 70% of the total population in France. The data are based on reimbursements of glucose testing and hospitalization among people who did not received reimbursements of treatment for diabetes but used medical services during the 2 Years. The opportunistic screening rate within 2 Years was 48.6% overall and increased with age. Among those 45 Years old or older, it was 71.2%. The screening rate was higher among women than men. Opportunistic screening for diabetes is commonly practised in France, despite the lack of official guidelines. Several hypotheses may explain the discrepancy between common opportunist screening and high prevalence of undiagnosed diabetes: 1). undiagnosed diabetes is mostly present in people who do not use medical services; 2). opportunistic screening is not performed among the most at-risk population; 3). testing is not performed on fasting samples or results are neglected; 4). results of testing are overlooked by doctors/patients; 5). epidemiological studies based on self-report of diagnosis and only one testing overestimate undiagnosed diabetes.
CT colonography: accuracy, acceptance, safety and position in organised population screening.
de Haan, Margriet C; Pickhardt, Perry J; Stoker, Jaap
2015-02-01
Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. The introduction of CRC screening programmes using stool tests and flexible sigmoidoscopy, have been shown to reduce CRC-related mortality substantially. In several European countries, population-based CRC screening programmes are ongoing or being rolled out. Stool tests like faecal occult blood testing are non-invasive and simple to perform, but are primarily designed to detect early invasive cancer. More invasive tests like colonoscopy and CT colonography (CTC) aim at accurately detecting both CRC and cancer precursors, thus providing for cancer prevention. This review focuses on the accuracy, acceptance and safety of CTC as a CRC screening technique and on the current position of CTC in organised population screening. Based on the detection characteristics and acceptability of CTC screening, it might be a viable screening test. The potential disadvantage of radiation exposure is probably overemphasised, especially with newer technology. At this time-point, it is not entirely clear whether the detection of extracolonic findings at CTC is of net benefit and is cost effective, but with responsible handling, this may be the case. Future efforts will seek to further improve the technique, refine appropriate diagnostic algorithms and study cost-effectiveness. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
A New Interactive Screening Test for Autism Spectrum Disorders in Toddlers.
Choueiri, Roula; Wagner, Sheldon
2015-08-01
To develop a clinically valid interactive level 2 screening assessment for autism spectrum disorders (ASD) in toddlers that is brief, easily administered, and scored by clinicians. We describe the development, training, standardization, and validation of the Rapid Interactive Screening Test for Autism in Toddlers (RITA-T) with ASD-specific diagnostic instruments. The RITA-T can be administered and scored in 10 minutes. We studied the validity of the RITA-T to distinguish between toddlers with ASD from toddlers with developmental delay (DD)/non-ASD in an early childhood clinic. We also evaluated the test's performance in toddlers with no developmental concerns. We identified a cutoff score based on sensitivity, specificity, and positive predictive value of the RITA-T that best differentiates between ASD and DD/non-ASD. A total of 61 toddlers were enrolled. RITA-T scores were correlated with ASD-specific diagnostic tools (r = 0.79; P < .01) and ASD clinical diagnoses (r = 0.77; P < .01). Mean scores were significantly different in subjects with ASD, those with DD/non-ASD, and those with no developmental concerns (20.8 vs 13 vs 10.6, respectively; P < .0001). At a cutoff score of >14 , the RITA-T had a sensitivity of 1.00, specificity of 0.84, and positive predictive value of 0.88 for identifying ASD risk in a high-risk group. The RITA-T is a promising new level 2 interactive screening tool for improving the early identification of ASD in toddlers in general pediatric and early intervention settings and allowing access to treatment. Copyright © 2015 Elsevier Inc. All rights reserved.
The value of the first trimester ultrasound in the era of cell free DNA screening.
Rao, Rashmi R; Valderramos, Stephanie G; Silverman, Neil S; Han, Christina S; Platt, Lawrence D
2016-12-01
To describe the clinically relevant findings detected by the first trimester ultrasound (FTU) and to determine the additional value of the FTU compared to cell free DNA (cfDNA) alone. Retrospective cohort study of patients undergoing a FTU at a maternal-fetal medicine referral practice. Fetal, gynecologic, and placental findings detected by ultrasound were analyzed with available cfDNA and diagnostic testing results. A subgroup analysis of positive ultrasound findings and cfDNA results was performed to assess the additional benefit of ultrasound evaluation in FT prenatal screening. There were 1906 FTU between 1 October 2013 and 1 October 2014. CfDNA results were available for 959 (50%) patients. FTU detected: 42 fetal (2.2%), 286 gynecologic (15.0%), and 317 placental (16.6%) findings. CfDNA results were discordant with invasive testing results in 8/61 cases (13%) and with ultrasound findings in 18/42 (42%) cases. There were six false positive and two false negative cfDNA results confirmed by diagnostic testing. Subgroup analysis revealed that cfDNA as the sole method of prenatal screening in the FT would miss 95% of the fetal findings detected with ultrasound. The comprehensive FTU provides valuable clinical information about fetal and maternal anatomy that cannot be detected with cfDNA alone. © 2016 John Wiley & Sons, Ltd. © 2016 John Wiley & Sons, Ltd.
21 CFR 884.2980 - Telethermographic system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...
21 CFR 884.2980 - Telethermographic system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...
21 CFR 884.2980 - Telethermographic system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...
21 CFR 884.2980 - Telethermographic system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...
21 CFR 884.2980 - Telethermographic system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... screening for detection of breast cancer or other uses—(1) Identification. A telethermographic system for adjunctive diagnostic screening for detection of breast cancer or other uses is an electrically powered... system intended for use alone in diagnostic screening for detection of breast cancer or other uses—(1...
The diagnosis of cystic fibrosis.
De Boeck, Kris; Vermeulen, Francois; Dupont, Lieven
2017-06-01
Establishing the diagnosis of cystic fibrosis (CF) is straight forward in the majority of patients: they present with a clear clinical picture (most frequently chronic respiratory symptoms plus malabsorption), the sweat chloride value is>60mmol/L and two known disease causing CFTR mutations are identified. In less than 5% of subjects, mainly those with a milder or limited phenotype, the diagnostic process is more complex, because initial diagnostic test results are inconclusive: sweat chloride concentration in the intermediate range, less than 2 CF causing mutations identified or both. These patients should be referred to expert centers where bioassays of CFTR function like nasal potential difference measurement or intestinal current measurement can be done. Still, in some patients, despite symptoms compatible with CF and some indication of CFTR dysfunction (e.g. only intermediate sweat chloride value), diagnostic criteria are not met (e.g. only 1 CFTR mutation identified). For these subjects, the term CFTR related disorder (CFTR-RD) is used. Patients with disseminated bronchiectasis, congenital bilateral absence of the vas deferens and acute or recurrent pancreatitis may fall in this category. CF has a very wide disease spectrum and increasingly the diagnosis is being made during adult life, mainly in subjects with milder phenotypes. In many countries, nationwide CF newborn screening (NBS) has been introduced. In screen positive babies, the diagnosis of CF must be confirmed by a sweat test demonstrating a sweat chloride concentration above 60mmol/L. To achieve the benefit of NBS, every baby in whom the diagnosis of CF is confirmed must receive immediate follow-up and treatment in a CF reference center. CF NBS is not full proof: some diagnoses will be missed and in some babies the diagnosis cannot be confirmed nor ruled out with certainty. Screening algorithms that include gene sequencing will detect a high number of such babies that are screen positive with an inconclusive diagnosis (CFSPID). Even in 2016, the most reliable and widely available diagnostic test for CF is the measurement of chloride concentration in sweat. The method of choice is sweat induction by pilocarpine iontophoresis, followed by sweat collection on a gauze or filter paper or in a Macroduct coil. Since mutation specific therapies have become available, it is important to identify the mutations responsible for CF in each individual patient. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Validation of the Cross-Cultural Alcoholism Screening Test (CCAST).
Gorenc, K D; Peredo, S; Pacurucu, S; Llanos, R; Vincente, B; López, R; Abreu, L F; Paez, E
1999-01-01
When screening instruments that are used in the assessment and diagnosis of alcoholism of individuals from different ethnicities, some cultural variables based on norms and societal acceptance of drinking behavior can play an important role in determining the outcome. The accepted diagnostic criteria of current market testing are based on Western standards. In this study, the Munich Alcoholism Test (31 items) was the base instrument applied to subjects from several Hispanic-American countries (Bolivia, Chile, Ecuador, Mexico, and Peru). After the sample was submitted to several statistical procedures, these 31 items were reduced to a culture-free, 31-item test named the Cross-Cultural Alcohol Screening Test (CCAST). The results of this Hispanic-American sample (n = 2,107) empirically demonstrated that CCAST measures alcoholism with an adequate degree of accuracy when compared to other available cross-cultural tests. CCAST is useful in the diagnosis of alcoholism in Spanish-speaking immigrants living in countries where English is spoken. CCAST can be used in general hospitals, psychiatric wards, emergency services and police stations. The test can be useful for other professionals, such as psychological consultants, researchers, and those conducting expertise appraisal.
Demilie, Tazebew; Beyene, Getenet; Melaku, Selabat; Tsegaye, Wondewosen
2014-07-29
Untreated bacteriuria during pregnancy has been shown to be associated with low birth-weight and premature delivery. Therefore, routine screening for bacteriuria is advocated. The decision about how to screen pregnant women for bacteriuria has always been a balance between the cost of screening versus the sensitivity and specificity. This study was designed to evaluate the diagnostic accuracy of the rapid dipstick test to predict urinary tract infection in pregnancy against the gold standard urine culture. A total of 367 mid stream urine samples were collected, inoculated on MacConkey, Manitol salt agar (MSA) and blood agar and incubated aerobically at 37°C for overnight. Specimens were classified as "positive" for urinary tract infection (UTI) if the growth of the pathogen(s) was at a count ≥ 10(5) colony-forming units per milliliter (cfu/mL) of urine and classified as "negative" with growth of <10(5) cfu/mL. Urine samples were tested for the presence of nitrite and leukocyte esterase using dipstick rapid test in accordance to the manufacturer's instructions. From the total study participants, 37 pregnant women were symptomatic and the remaining 330 pregnant women were asymptomatic. The sensitivity and specificity of dipstick tests of leukocyte esterase was 50% and 89.1% for pregnant women with asymptomatic UTI(ABU) and 71.4% and 86.7% for symptomatic UTI respectively and for nitrite 35.7% and 98.0% for ABU and 57.1% and 96.7% symptomatic UTI. This study revealed that the use of dipstick leukocyte esterase and nitrite for screening UTI particularly asymptomatic bacteriuria was associated with many false positive and negative results when it was compared against the gold standard culture method. The low sensitivity and positive predictive value of urine dipstick test proved that culture should be used for the diagnosis of UTI.
Laboratory screening markers in gastroenterology--state of the art.
Kocna, Petr; Vanickova, Zdislava; Zima, Tomas
2013-06-01
Screening tests for gastrointestinal diseases acceptable for population with a high sensitivity and high specificity can now be offered by clinical laboratories. This paper summarizes major recent advances in this area of laboratory medicine. Relevant articles published within the last 5 years in the NLM (National Library of Medicine) PubMed - Medline database covering the three gastrointestinal diseases - colorectal cancer, coeliac disease, and atrophic gastritis were included for this overview. In Europe, colorectal cancer (CRCA) is the second most frequent malignant disease. Quantitative immunochemical analysis of the stool for haemoglobin provides the best screening test to date, with both sensitivity and specificity approaching 95%. Even though coeliac disease (CD) affects approximately 1% of the general population, it remains largely unrecognised. Recommended methods for screening currently involve the detection of IgA and IgG antibodies against tissue transglutaminase and deamidated gliadin peptide. Evaluations of screening are now discussed for other diseases of the gastrointestinal tract - such as chronic atrophic gastritis (CAG), and inflammatory bowel disease (IBD). Detection of infection by Helicobacter pylori and stomach-specific plasmatic biomarkers, especially pepsinogen I/II ratio, could help with the prevention of gastric carcinomas. The use of faecal calprotectin as a screening test could substantially reduce the number of invasive methods necessary for the diagnostic work-up of patients with IBD. Screening tests for CRCA and CD have been used worldwide for many years. Screening strategies for gastrointestinal diseases are suggested in the text, based on recent basic science, clinical papers as well as our own experience.
Efficient screening for COPD using three steps: a cross-sectional study in Mexico City.
Franco-Marina, Francisco; Fernandez-Plata, Rosario; Torre-Bouscoulet, Luis; García-Sancho, Cecilia; Sanchez-Gallen, Elisa; Martinez, David; Perez-Padilla, Rogelio
2014-05-20
Underdiagnosis of chronic obstructive pulmonary disease (COPD) in primary care can be improved by a more efficient screening strategy. To evaluate a three-step method of screening for COPD consisting of an initial short questionnaire followed by measurement of forced expiratory volume in 1s/forced expiratory volume in 6s (FEV1/FEV6) using an inexpensive pocket spirometer in those with high risk, and diagnostic quality spirometry in those with a low FEV1/FEV6. We analysed two related Mexico City cross-sectional samples. The 2003 Mexico City PLATINO survey (n=542) was used to develop a short questionnaire to determine the risk of COPD and a 2010 survey (n=737) additionally used a pocket spirometer. The discriminatory power of the two instruments was assessed with receiver operator characteristic (ROC) curves using three COPD definitions. The developed COPD scale included two variables from a simple questionnaire and, in ROC analysis, an area under the curve (AUC) between 0.64 and 0.77 was found to detect COPD. The pocket spirometer had an AUC between 0.85 and 0.88 to detect COPD. Using the COPD scale as a first screening step excluded 35-48% of the total population from further testing at the cost of not detecting 8-18% of those with COPD. Using the pocket spirometer and sending those with a FEV1/FEV6<0.80 for diagnostic quality spirometry is very efficient, and substantially improved the positive predictive value at the cost of not detecting one-third of COPD cases. A three-step screening strategy for COPD substantially reduces the need for spirometry testing when only a COPD scale is used for screening.
Barbee, Lindley A; Tat, Susana; Dhanireddy, Shireesha; Marrazzo, Jeanne M
2016-06-01
Rates of screening for bacterial sexually transmitted infections (STI) among men who have sex with men in HIV care settings remain low despite high prevalence of these infections. STI self-testing may help increase screening rates in clinical settings. We implemented an STI self-testing program at a large, urban HIV care clinic and evaluated its effectiveness and acceptability. We compared measures obtained during the first year of the STI self-testing program (Intervention Year, April 1, 2013-March 31, 2014) to Baseline Year (January 1, 2012-December 31, 2012) to determine: (1) overall clinic change in STI testing coverage and diagnostic yield and; (2) program-specific outcomes including appropriate anatomic site screening and patient-reported acceptability. Overall, testing for gonorrhea and chlamydia increased significantly between Baseline and Intervention Year, and 50% more gonococcal and 47% more chlamydial infections were detected. Syphilis testing coverage remained unchanged. Nearly 95% of 350 men who participated in the STI self-testing program completed site-specific testing appropriately based on self-reported exposures, and 92% rated their self-testing experience as "good" or "very good." STI self-testing in HIV care settings significantly increases testing coverage and detection of gonorrhea and chlamydia, and the program is acceptable to patients. Additional interventions to increase syphilis screening rates are needed.
Diagnostic Accuracy of Obstructive Airway Adult Test for Diagnosis of Obstructive Sleep Apnea.
Gasparini, Giulio; Vicini, Claudio; De Benedetto, Michele; Salamanca, Fabrizio; Sorrenti, Giovanni; Romandini, Mario; Bosi, Marcello; Saponaro, Gianmarco; Foresta, Enrico; Laforì, Andreina; Meccariello, Giuseppe; Bianchi, Alessandro; Toraldo, Domenico Maurizio; Campanini, Aldo; Montevecchi, Filippo; Rizzotto, Grazia; Cervelli, Daniele; Moro, Alessandro; Arigliani, Michele; Gobbi, Riccardo; Pelo, Sandro
2015-01-01
The gold standard for the diagnosis of Obstructive Sleep Apnea (OSA) is polysomnography, whose access is however reduced by costs and limited availability, so that additional diagnostic tests are needed. To analyze the diagnostic accuracy of the Obstructive Airway Adult Test (OAAT) compared to polysomnography for the diagnosis of OSA in adult patients. Ninety patients affected by OSA verified with polysomnography (AHI ≥ 5) and ten healthy patients, randomly selected, were included and all were interviewed by one blind examiner with OAAT questions. The Spearman rho, evaluated to measure the correlation between OAAT and polysomnography, was 0.72 (p < 0.01). The area under the ROC curve (95% CI) was the parameter to evaluate the accuracy of the OAAT: it was 0.91 (0.81-1.00) for the diagnosis of OSA (AHI ≥ 5), 0.90 (0.82-0.98) for moderate OSA (AHI ≥ 15), and 0.84 (0.76-0.92) for severe OSA (AHI ≥ 30). The OAAT has shown a high correlation with polysomnography and also a high diagnostic accuracy for the diagnosis of OSA. It has also been shown to be able to discriminate among the different degrees of severity of OSA. Additional large studies aiming to validate this questionnaire as a screening or diagnostic test are needed.
Comparing Computer-Adaptive and Curriculum-Based Measurement Methods of Assessment
ERIC Educational Resources Information Center
Shapiro, Edward S.; Gebhardt, Sarah N.
2012-01-01
This article reported the concurrent, predictive, and diagnostic accuracy of a computer-adaptive test (CAT) and curriculum-based measurements (CBM; both computation and concepts/application measures) for universal screening in mathematics among students in first through fourth grade. Correlational analyses indicated moderate to strong…
Urine tests for Down's syndrome screening.
Alldred, S Kate; Guo, Boliang; Takwoingi, Yemisi; Pennant, Mary; Wisniewski, Susanna; Deeks, Jonathan J; Neilson, James P; Alfirevic, Zarko
2015-12-10
Down's syndrome occurs when a person has three copies of chromosome 21, or the specific area of chromosome 21 implicated in causing Down's syndrome, rather than two. It is the commonest congenital cause of mental disability and also leads to numerous metabolic and structural problems. It can be life-threatening, or lead to considerable ill health, although some individuals have only mild problems and can lead relatively normal lives. Having a baby with Down's syndrome is likely to have a significant impact on family life. The risk of a Down's syndrome affected pregnancy increases with advancing maternal age.Noninvasive screening based on biochemical analysis of maternal serum or urine, or fetal ultrasound measurements, allows estimates of the risk of a pregnancy being affected and provides information to guide decisions about definitive testing. Before agreeing to screening tests, parents need to be fully informed about the risks, benefits and possible consequences of such a test. This includes subsequent choices for further tests they may face, and the implications of both false positive and false negative screening tests (i.e. invasive diagnostic testing, and the possibility that a miscarried fetus may be chromosomally normal). The decisions that may be faced by expectant parents inevitably engender a high level of anxiety at all stages of the screening process, and the outcomes of screening can be associated with considerable physical and psychological morbidity. No screening test can predict the severity of problems a person with Down's syndrome will have. To estimate and compare the accuracy of first and second trimester urine markers for the detection of Down's syndrome. We carried out a sensitive and comprehensive literature search of MEDLINE (1980 to 25 August 2011), EMBASE (1980 to 25 August 2011), BIOSIS via EDINA (1985 to 25 August 2011), CINAHL via OVID (1982 to 25 August 2011), The Database of Abstracts of Reviews of Effectiveness (The Cochrane Library 2011, Issue 7), MEDION (25 August 2011), The Database of Systematic Reviews and Meta-Analyses in Laboratory Medicine (25 August 2011), The National Research Register (archived 2007), Health Services Research Projects in Progress database (25 August 2011). We studied reference lists and published review articles. Studies evaluating tests of maternal urine in women up to 24 weeks of gestation for Down's syndrome, compared with a reference standard, either chromosomal verification or macroscopic postnatal inspection. We extracted data as test positive or test negative results for Down's and non-Down's pregnancies allowing estimation of detection rates (sensitivity) and false positive rates (1-specificity). We performed quality assessment according to QUADAS (Quality Assessment of Diagnostic Accuracy Studies) criteria. We used hierarchical summary ROC (receiver operating characteristic) meta-analytical methods to analyse test performance and compare test accuracy. We performed analysis of studies allowing direct comparison between tests. We investigated the impact of maternal age on test performance in subgroup analyses. We included 19 studies involving 18,013 pregnancies (including 527 with Down's syndrome). Studies were generally of high quality, although differential verification was common with invasive testing of only high-risk pregnancies. Twenty-four test combinations were evaluated formed from combinations of the following seven different markers with and without maternal age: AFP (alpha-fetoprotein), ITA (invasive trophoblast antigen), ß-core fragment, free ßhCG (beta human chorionic gonadotrophin), total hCG, oestriol, gonadotropin peptide and various marker ratios. The strategies evaluated included three double tests and seven single tests in combination with maternal age, and one triple test, two double tests and 11 single tests without maternal age. Twelve of the 19 studies only evaluated the performance of a single test strategy while the remaining seven evaluated at least two test strategies. Two marker combinations were evaluated in more than four studies; second trimester ß-core fragment (six studies), and second trimester ß-core fragment with maternal age (five studies).In direct test comparisons, for a 5% false positive rate (FPR), the diagnostic accuracy of the double marker second trimester ß-core fragment and oestriol with maternal age test combination was significantly better (ratio of diagnostic odds ratio (RDOR): 2.2 (95% confidence interval (CI) 1.1 to 4.5), P = 0.02) (summary sensitivity of 73% (CI 57 to 85) at a cut-point of 5% FPR) than that of the single marker test strategy of second trimester ß-core fragment and maternal age (summary sensitivity of 56% (CI 45 to 66) at a cut-point of 5% FPR), but was not significantly better (RDOR: 1.5 (0.8 to 2.8), P = 0.21) than that of the second trimester ß-core fragment to oestriol ratio and maternal age test strategy (summary sensitivity of 71% (CI 51 to 86) at a cut-point of 5% FPR). Tests involving second trimester ß-core fragment and oestriol with maternal age are significantly more sensitive than the single marker second trimester ß-core fragment and maternal age, however, there were few studies. There is a paucity of evidence available to support the use of urine testing for Down's syndrome screening in clinical practice where alternatives are available.
Shete, Anita M; Yadav, Pragya; Kumar, Vimal; Nikam, Tushar; Mehershahi, Kurosh; Kokate, Prasad; Patil, Deepak; Mourya, Devendra T
2017-01-01
Bats are recognized as important reservoirs for emerging infectious disease and some unknown viral diseases. Two novel viruses, Malsoor virus (family Bunyaviridae, genus, Phlebovirus) and a novel adenovirus (AdV) (family, Adenoviridae genus, Mastadenovirus), were identified from Rousettus bats in the Maharashtra State of India. This study was done to develop and optimize real time reverse transcription - polymerase chain reaction (RT-PCR) assays for Malsoor virus and real time and nested PCR for adenovirus from Rousettus bats. For rapid and accurate screening of Malsoor virus and adenovirus a nested polymerase chain reaction and TaqMan-based real-time PCR were developed. Highly conserved region of nucleoprotein gene of phleboviruses and polymerase gene sequence from the Indian bat AdV isolate polyprotein gene were selected respectively for diagnostic assay development of Malsoor virus and AdV. Sensitivity and specificity of assays were calculated and optimized assays were used to screen bat samples. Molecular diagnostic assays were developed for screening of Malsoor virus and AdV and those were found to be specific. Based on the experiments performed with different parameters, nested PCR was found to be more sensitive than real-time PCR; however, for rapid screening, real-time PCR can be used and further nested PCR can be used for final confirmation or in those laboratories where real-time facility/expertise is not existing. This study reports the development and optimization of nested RT-PCR and a TaqMan-based real-time PCR for Malsoor virus and AdV. The diagnostic assays can be used for rapid detection of these novel viruses to understand their prevalence among bat population.
Haemoglobinopathy diagnosis: algorithms, lessons and pitfalls.
Bain, Barbara J
2011-09-01
Diagnosis of haemoglobinopathies, including thalassaemias, can result from either a clinical suspicion of a disorder of globin chain synthesis or from follow-up of an abnormality detected during screening. Screening may be carried out as part of a well defined screening programme or be an ad hoc or opportunistic test. Screening may be preoperative, neonatal, antenatal, preconceptual, premarriage or targeted at specific groups perceived to be at risk. Screening in the setting of haemoglobinopathies may be directed at optimising management of a disorder by early diagnosis, permitting informed reproductive choice or preventing a serious disorder by offering termination of pregnancy. Diagnostic methods and algorithms will differ according to the setting. As the primary test, high performance liquid chromatography is increasingly used and haemoglobin electrophoresis less so with isoelectric focussing being largely confined to screening programmes and referral centres, particularly in newborns. Capillary electrophoresis is being increasingly used. All these methods permit only a presumptive diagnosis with definitive diagnosis requiring either DNA analysis or protein analysis, for example by tandem mass spectrometry. Copyright © 2011 Elsevier Ltd. All rights reserved.
Ade, Maria Paz; Baird, J. Kevin; Cheng, Qin; Cunningham, Jane; Dhorda, Mehul; Drakeley, Chris; Felger, Ingrid; Gamboa, Dionicia; Harbers, Matthias; Herrera, Socrates; Lucchi, Naomi; Mayor, Alfredo; Mueller, Ivo; Sattabongkot, Jetsumon; Ratsimbason, Arsène; Richards, Jack; Tanner, Marcel; González, Iveth J.
2017-01-01
The global prevalence of malaria has decreased over the past fifteen years, but similar gains have not been realized against Plasmodium vivax because this species is less responsive to conventional malaria control interventions aimed principally at P. falciparum. Approximately half of all malaria cases outside of Africa are caused by P. vivax. This species places dormant forms in human liver that cause repeated clinical attacks without involving another mosquito bite. The diagnosis of acute patent P. vivax malaria relies primarily on light microscopy. Specific rapid diagnostic tests exist but typically perform relatively poorly compared to those for P. falciparum. Better diagnostic tests are needed for P. vivax. To guide their development, FIND, in collaboration with P. vivax experts, identified the specific diagnostic needs associated with this species and defined a series of three distinct target product profiles, each aimed at a particular diagnostic application: (i) point-of-care of acutely ill patients for clinical care purposes; (ii) point-of-care asymptomatic and otherwise sub-patent residents for public health purposes, e.g., mass screen and treat campaigns; and (iii) ultra-sensitive not point-of-care diagnosis for epidemiological research/surveillance purposes. This report presents and discusses the rationale for these P. vivax-specific diagnostic target product profiles. These contribute to the rational development of fit-for-purpose diagnostic tests suitable for the clinical management, control and elimination of P. vivax malaria. PMID:28369085
McLennan, Andrew; Palma-Dias, Ricardo; da Silva Costa, Fabricio; Meagher, Simon; Nisbet, Debbie L; Scott, Fergus
2016-02-01
There are limited data regarding noninvasive prenatal testing (NIPT) in low-risk populations, and the ideal aneuploidy screening model for a pregnant population has yet to be established. To assess the implementation of NIPT into clinical practice utilising both first- and second-line screening models. Three private practices specialising in obstetric ultrasound and prenatal diagnosis in Australia offered NIPT as a first-line test, ideally followed by combined first-trimester screening (cFTS), or as a second-line test following cFTS, particularly in those with a calculated risk between 1:50 and 1:1000. NIPT screening was performed in 5267 women and as a first-line screening method in 3359 (63.8%). Trisomies 21 and 13 detection was 100% and 88% for trisomy 18. Of cases with known karyotypes, the positive predictive value (PPV) of the test was highest for trisomy 21 (97.7%) and lowest for monosomy X (25%). Ultrasound detection of fetal structural abnormality resulted in the detection of five additional chromosome abnormalities, two of which had high-risk cFTS results. For all chromosomal abnormalities, NIPT alone detected 93.4%, a contingent model detected 81.8% (P = 0.097), and cFTS alone detected 65.9% (P < 0.005). NIPT achieved 100% T21 detection and had a higher DR of all aneuploidy when used as a first-line test. Given the false-positive rate for all aneuploidies, NIPT is an advanced screening test, rather than a diagnostic test. The benefit of additional cFTS was the detection of fetal structural abnormalities and some unusual chromosomal abnormalities. © 2016 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
The impact of digital imaging in the field of cytopathology.
Pantanowitz, Liron; Hornish, Maryanne; Goulart, Robert A
2009-03-06
With the introduction of digital imaging, pathology is undergoing a digital transformation. In the field of cytology, digital images are being used for telecytology, automated screening of Pap test slides, training and education (e.g. online digital atlases), and proficiency testing. To date, there has been no systematic review on the impact of digital imaging on the practice of cytopathology. This article critically addresses the emerging role of computer-assisted screening and the application of digital imaging to the field of cytology, including telecytology, virtual microscopy, and the impact of online cytology resources. The role of novel diagnostic techniques like image cytometry is also reviewed.
A single-question screening test for drug use in primary care.
Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard
2010-07-12
Drug use (illicit drug use and nonmedical use of prescription drugs) is common but underrecognized in primary care settings. We validated a single-question screening test for drug use and drug use disorders in primary care. Adult patients recruited from primary care waiting rooms were asked the single screening question, "How many times in the past year have you used an illegal drug or used a prescription medication for nonmedical reasons?" A response of at least 1 time was considered positive for drug use. They were also asked the 10-item Drug Abuse Screening Test (DAST-10). The reference standard was the presence or absence of current (past year) drug use or a drug use disorder (abuse or dependence) as determined by a standardized diagnostic interview. Drug use was also determined by oral fluid testing for common drugs of abuse. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single screening question was 100% sensitive (95% confidence interval [CI], 90.6%-100%) and 73.5% specific (95% CI, 67.7%-78.6%) for the detection of a drug use disorder. It was less sensitive for the detection of self-reported current drug use (92.9%; 95% CI, 86.1%-96.5%) and drug use detected by oral fluid testing or self-report (81.8%; 95% CI, 72.5%-88.5%). Test characteristics were similar to those of the DAST-10 and were affected very little by participant demographic characteristics. The single screening question accurately identified drug use in this sample of primary care patients, supporting the usefulness of this brief screen in primary care.
Berg, Wendie A.; Blume, Jeffrey D.; Cormack, Jean B.; Mendelson, Ellen B.; Lehrer, Daniel; Böhm-Vélez, Marcela; Pisano, Etta D.; Jong, Roberta A.; Evans, W. Phil; Morton, Marilyn J.; Mahoney, Mary C.; Larsen, Linda Hovanessian; Barr, Richard G.; Farria, Dione M.; Marques, Helga S.; Boparai, Karan
2008-01-01
Context Screening ultrasound (US) may depict small, node-negative breast cancers not seen on mammography (M). Objective To compare the diagnostic yield (proportion of women with a positive screen test and positive reference standard) and performance of screening with US+M compared to M alone in women at elevated risk of breast cancer. Design, Setting, and Participants From April 2004 to February 2006, 2809 women at elevated risk for breast cancer, with at least heterogeneously dense breast tissue in at least one quadrant, were recruited from 21 IRB-approved sites to undergo mammography (M) and physician-performed ultrasound (US) exams in randomized order by a radiologist masked to the results of the other exam. Reference standard was defined as a combination of pathology and 12 month follow-up, and was available for 2637 out of the 2725 eligible participants. Main Outcome Measure Diagnostic yield, sensitivity, specificity, and AUC of combined M+US compared to M alone; PPV of biopsy recommendations for M+US compared to M alone. Results Forty participants (41 breasts) were diagnosed with cancer: 8 suspicious on both US and M, 12 on US alone, 12 on M alone, and 8 participants (9 breasts) on neither (interval cancers). The diagnostic yield for M was 7.6 per 1000 women screened (20/2637) and increased to 11.8 per 1000 (31/2637) for combined US+M; the supplemental yield was 4.2 per 1000 women screened (95% CI 1.1 to 7.2 per 1000; p = 0.003 that the supplemental yield is zero). The diagnostic accuracy (AUC) for M was 0.78 (95% CI 0.67 to 0.87) and increased to 0.91 (95% CI 0.84 to 0.96) for US+M (p = 0.003 that difference is zero). Of 12 supplemental cancers seen only by US, 11 (92%) were invasive with median size 10 mm (range 5 to 40 mm; mean 12.6, SE 3.0) and 8/9 (89%) reported had negative nodes. PPV of biopsy recommendation after full diagnostic workup (PPV2) was 84/276 for M (22.6%, 95% CI 14.2 to 33%), 21/235 for US (8.9%, 95% CI 5.6 to 13.3%), and 31/276 for combined US+M (11.2%, 95% CI 7.8 to 15.6%). Conclusions Adding a single screening US to M will yield an additional 1.1 to 7.2 cancers per 1000 high-risk women, but will also substantially increase the number of false positives. Evaluation of the role of annual screening US is ongoing in this patient population. [Clinicaltrials.gov registry # NCT00072501] PMID:18477782
Taif, Sawsan; Tufail, Fatma; Alnuaimi, Ahmed Sameer
2016-06-01
The aim of this study is to assess mammography performance in Oman by estimating the breast cancer rate and the positive predictive value (PPV) with the influence of some variables. This cross-sectional study was conducted on mammograms done in one of the three main breast imaging centers in Oman between January 2008 and July 2012. Diagnostic and screening groups were identified and assessed separately. Rate of abnormal mammograms, rate of breast cancer and the PPV were estimated according to Breast Imaging Reporting and Data System (BIRADS) score, presence of breast lump and patient's age. Total of 653 mammograms were included, 254 diagnostic and 399 screening. Abnormal mammograms (BIRADS 4 and 5) form 31.9% of the diagnostic examinations compared with 6.8% of screening examinations. Breast cancer was present in 17.9% of the diagnostic compared with 1.0% of the screening group. The PPV of BIRADS 5 was 94.1%, and for BIRADS 4 was 37.1 and 26.7% for diagnostic and screening studies. Overall PPV for abnormal mammograms was 65.2% in the diagnostic and 26.7% in the screening group. Mammography PPV shows positive association with age (P = 0.039) while presence of breast lump has no significant effect on the PPV (P = 0.38). BIRADS 5 score was found to have a high cancer yield making it a strong predictor of cancer. Different results were obtained in the diagnostic compared with screening mammography with higher rates of abnormal mammograms and breast cancer. Mammography performance should be better in the older women. © 2014 Wiley Publishing Asia Pty Ltd.
Array-on-a-disk? How Blu-ray technology can be applied to molecular diagnostics.
Morais, Sergi; Tortajada-Genaro, Luis; Maquieira, Angel
2014-09-01
This editorial comments on the balance and perspectives of compact disk technology applied to molecular diagnostics. The development of sensitive, rapid and multiplex assays using Blu-ray technology for the determination of biomarkers, drug allergens, pathogens and detection of infections would have a direct impact on diagnostics. Effective tests for use in clinical, environmental and food applications require versatile and low-cost platforms as well as cost-effective detectors. Blu-ray technology accomplishes those requirements and advances on the concept of high density arrays for massive screening to achieve the demands of point of care or in situ analysis.
Pastakia, Sonak D; Njuguna, Benson; Onyango, Beryl Ajwang'; Washington, Sierra; Christoffersen-Deb, Astrid; Kosgei, Wycliffe K; Saravanan, Ponnusamy
2017-07-14
Early diagnosis of gestational diabetes mellitus (GDM) is crucial to prevent short term delivery risks and long term effects such as cardiovascular and metabolic diseases in the mother and infant. Diagnosing GDM in Sub-Saharan Africa (SSA) however, remains sub-optimal due to associated logistical and cost barriers for resource-constrained populations. A cost-effective strategy to screen for GDM in such settings are therefore urgently required. We conducted this study to determine the prevalence of gestational diabetes mellitus (GDM) and assess utility of various GDM point of care (POC) screening strategies in a resource-constrained setting. Eligible women aged ≥18 years, and between 24 and 32 weeks of a singleton pregnancy, prospectively underwent testing over two days. On day 1, a POC 1-h 50 g glucose challenge test (GCT) and a POC glycated hemoglobin (HbA1c) was assessed. On day 2, fasting blood glucose, 1-h and 2-h 75 g oral glucose tolerance test (OGTT) were determined using both venous and POC tests, along with a venous HbA1c. The International Association of Diabetes in Pregnancy Study Group (IADPSG) criteria was used to diagnose GDM. GDM prevalence was reported with 95% confidence interval (CI). Specificity, sensitivity, positive predictive value, and negative predictive value of the various POC testing strategies were determined using IADPSG testing as the standard reference. Six hundred-sixteen eligible women completed testing procedures. GDM was diagnosed in 18 women, a prevalence of 2.9% (95% CI, 1.57% - 4.23%). Compared to IADPSG testing, POC IADPSG had a sensitivity and specificity of 55.6% and 90.6% respectively while that of POC 1-h 50 g GCT (using a diagnostic cut-off of ≥7.2 mmol/L [129.6 mg/dL]) was 55.6% and 63.9%. All other POC tests assessed showed poor sensitivity. POC screening strategies though feasible, showed poor sensitivity for GDM detection in our resource-constrained population of low GDM prevalence. Studies to identify sensitive and specific POC GDM screening strategies using adverse pregnancy outcomes as end points are required. Clinical trials.gov : NCT02978807 , Registered 29 November 2016.
Bickelhaupt, Sebastian; Laun, Frederik B; Tesdorff, Jana; Lederer, Wolfgang; Daniel, Heidi; Stieber, Anne; Delorme, Stefan; Schlemmer, Heinz-Peter
2016-03-01
To evaluate the ability of a diagnostic abbreviated magnetic resonance (MR) imaging protocol consisting of maximum intensity projections (MIPs) from diffusion-weighted imaging with background suppression (DWIBS) and unenhanced morphologic sequences to help predict the likelihood of malignancy on suspicious screening x-ray mammograms, as compared with an abbreviated contrast material-enhanced MR imaging protocol and a full diagnostic breast MR imaging protocol. This prospective institutional review board-approved study included 50 women (mean age, 57.1 years; range, 50-69 years), who gave informed consent and who had suspicious screening mammograms and an indication for biopsy, from September 2014 to January 2015. Before biopsy, full diagnostic contrast-enhanced MR imaging was performed that included DWIBS (b = 1500 sec/mm(2)). Two abbreviated protocols (APs) based on MIPs were evaluated regarding the potential to exclude malignancy: DWIBS (AP1) and subtraction images from the first postcontrast and the unenhanced series (AP2). Diagnostic indexes of both methods were examined by using the McNemar test and were compared with those of the full diagnostic protocol and histopathologic findings. Twenty-four of 50 participants had a breast carcinoma. With AP1 (DWIBS), the sensitivity was 0.92 (95% confidence interval [CI]: 0.73, 0.98), the specificity was 0.94 (95% CI: 0.77, 0.99), the negative predictive value (NPV) was 0.92 (95% CI: 0.75, 0.99), and the positive predictive value (PPV) was 0.93 (95% CI: 0.75, 0.99). The mean reading time was 29.7 seconds (range, 4.9-110.0 seconds) and was less than 3 seconds (range, 1.2-7.6 seconds) in the absence of suspicious findings on the DWIBS MIPs. With the AP2 protocol, the sensitivity was 0.85 (95% CI: 0.78, 0.95), the specificity was 0.90 (95% CI: 0.72, 0.97), the NPV was 0.87 (95% CI: 0.69, 0.95), the PPV was 0.89 (95% CI: 0.69, 0.97), and the mean reading time was 29.6 seconds (range, 6.0-100.0 seconds). Unenhanced diagnostic MR imaging (DWIBS mammography), with an NPV of 0.92 and an acquisition time of less than 7 minutes, could help exclude malignancy in women with suspicious x-ray screening mammograms. The method has the potential to reduce unnecessary invasive procedures and emotional distress for breast cancer screening participants if it is used as a complement after the regular screening clarification procedure.
Yakes, B J; Buijs, J; Elliott, C T; Campbell, K
2016-08-15
Research in biosensing approaches as alternative techniques for food diagnostics for the detection of chemical contaminants and foodborne pathogens has increased over the last twenty years. The key component of such tests is the biorecognition element whereby polyclonal or monoclonal antibodies still dominate the market. Traditionally the screening of sera or cell culture media for the selection of polyclonal or monoclonal candidate antibodies respectively has been performed by enzyme immunoassays. For niche toxin compounds, enzyme immunoassays can be expensive and/or prohibitive methodologies for antibody production due to limitations in toxin supply for conjugate production. Automated, self-regenerating, chip-based biosensors proven in food diagnostics may be utilised as rapid screening tools for antibody candidate selection. This work describes the use of both single channel and multi-channel surface plasmon resonance (SPR) biosensors for the selection and characterisation of antibodies, and their evaluation in shellfish tissue as standard techniques for the detection of domoic acid, as a model toxin compound. The key advantages in the use of these biosensor techniques for screening hybridomas in monoclonal antibody production were the real time observation of molecular interaction and rapid turnaround time in analysis compared to enzyme immunoassays. The multichannel prototype instrument was superior with 96 analyses completed in 2h compared to 12h for the single channel and over 24h for the ELISA immunoassay. Antibodies of high sensitivity, IC50's ranging from 4.8 to 6.9ng/mL for monoclonal and 2.3-6.0ng/mL for polyclonal, for the detection of domoic acid in a 1min analysis time were selected. Although there is a progression for biosensor technology towards low cost, multiplexed portable diagnostics for the food industry, there remains a place for laboratory-based SPR instrumentation for antibody development for food diagnostics as shown herein. Copyright © 2016 Elsevier B.V. All rights reserved.
2003-03-22
e.g., tuberculosis screening or a maximal treadmill test ); and 3) tertiary prevention limits disability and rehabilitation where the disease or injury...major city/county laboratories to develop the capacity to conduct rapid and accurate diagnostic and reference testing for select biologic agents likely...system, but it has not been thoroughly tested and coordinated in the civilian sector. The association of mass casualty care with hospital
Huhn, E A; Fischer, T; Göbl, C S; Todesco Bernasconi, M; Kreft, M; Kunze, M; Schoetzau, A; Dölzlmüller, E; Eppel, W; Husslein, P; Ochsenbein-Koelble, N; Zimmermann, R; Bäz, E; Prömpeler, H; Bruder, E; Hahn, S; Hoesli, I
2016-10-12
As the accurate diagnosis and treatment of gestational diabetes mellitus (GDM) is of increasing importance; new diagnostic approaches for the assessment of GDM in early pregnancy were recently suggested. We evaluate the diagnostic power of an 'early' oral glucose tolerance test (OGTT) 75 g and glycosylated fibronectin (glyFn) for GDM screening in a normal cohort. In a prospective cohort study, 748 singleton pregnancies are recruited in 6 centres in Switzerland, Austria and Germany. Women are screened for pre-existing diabetes mellitus and GDM by an 'early' OGTT 75 g and/or the new biomarker, glyFn, at 12-15 weeks of gestation. Different screening strategies are compared to evaluate the impact on detection of GDM by an OGTT 75 g at 24-28 weeks of gestation as recommended by the International Association of Diabetes and Pregnancy Study Groups (IADPSG). A new screening algorithm is created by using multivariable risk estimation based on 'early' OGTT 75 g and/or glyFn results, incorporating maternal risk factors. Recruitment began in May 2014. This study received ethical approval from the ethics committees in Basel, Zurich, Vienna, Salzburg and Freiburg. It was registered under http://www.ClinicalTrials.gov (NCT02035059) on 12 January 2014. Data will be presented at international conferences and published in peer-reviewed journals. NCT02035059. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Diagnostic accuracy of a two-item Drug Abuse Screening Test (DAST-2).
Tiet, Quyen Q; Leyva, Yani E; Moos, Rudolf H; Smith, Brandy
2017-11-01
Drug use is prevalent and costly to society, but individuals with drug use disorders (DUDs) are under-diagnosed and under-treated, particularly in primary care (PC) settings. Drug screening instruments have been developed to identify patients with DUDs and facilitate treatment. The Drug Abuse Screening Test (DAST) is one of the most well-known drug screening instruments. However, similar to many such instruments, it is too long for routine use in busy PC settings. This study developed and validated a briefer and more practical DAST for busy PC settings. We recruited 1300 PC patients in two Department of Veterans Affairs (VA) clinics. Participants responded to a structured diagnostic interview. We randomly selected half of the sample to develop and the other half to validate the new instrument. We employed signal detection techniques to select the best DAST items to identify DUDs (based on the MINI) and negative consequences of drug use (measured by the Inventory of Drug Use Consequences). Performance indicators were calculated. The two-item DAST (DAST-2) was 97% sensitive and 91% specific for DUDs in the development sample and 95% sensitive and 89% specific in the validation sample. It was highly sensitive and specific for DUD and negative consequences of drug use in subgroups of patients, including gender, age, race/ethnicity, marital status, educational level, and posttraumatic stress disorder status. The DAST-2 is an appropriate drug screening instrument for routine use in PC settings in the VA and may be applicable in broader range of PC clinics. Published by Elsevier Ltd.
Barry, Eleanor; Roberts, Samantha; Oke, Jason; Vijayaraghavan, Shanti; Normansell, Rebecca; Greenhalgh, Trisha
2017-01-04
To assess diagnostic accuracy of screening tests for pre-diabetes and efficacy of interventions (lifestyle or metformin) in preventing onset of type 2 diabetes in people with pre-diabetes. Systematic review and meta-analysis. Medline, PreMedline, and Embase. Study protocols and seminal papers were citation-tracked in Google Scholar to identify definitive trials and additional publications. Data on study design, methods, and findings were extracted onto Excel spreadsheets; a 20% sample was checked by a second researcher. Data extracted for screening tests included diagnostic accuracy and population prevalence. Two meta-analyses were performed, one summarising accuracy of screening tests (with the oral glucose tolerance test as the standard) for identification of pre-diabetes, and the other assessing relative risk of progression to type 2 diabetes after either lifestyle intervention or treatment with metformin. Empirical studies evaluating accuracy of tests for identification of pre-diabetes. Interventions (randomised trials and interventional studies) with a control group in people identified through screening. No language restrictions. 2874 titles were scanned and 148 papers (covering 138 studies) reviewed in full. The final analysis included 49 studies of screening tests (five of which were prevalence studies) and 50 intervention trials. HbA 1c had a mean sensitivity of 0.49 (95% confidence interval 0.40 to 0.58) and specificity of 0.79 (0.73 to 0.84), for identification of pre-diabetes, though different studies used different cut-off values. Fasting plasma glucose had a mean sensitivity of 0.25 (0.19 to 0.32) and specificity of 0.94 (0.92 to 0.96). Different measures of glycaemic abnormality identified different subpopulations (for example, 47% : of people with abnormal HbA 1c had no other glycaemic abnormality). Lifestyle interventions were associated with a 36% (28% to 43%) reduction in relative risk of type 2 diabetes over six months to six years, attenuating to 20% (8% to 31%) at follow-up in the period after the trails. HbA 1c is neither sensitive nor specific for detecting pre-diabetes; fasting glucose is specific but not sensitive. Interventions in people classified through screening as having pre-diabetes have some efficacy in preventing or delaying onset of type 2 diabetes in trial populations. As screening is inaccurate, many people will receives an incorrect diagnosis and be referred on for interventions while others will be falsely reassured and not offered the intervention. These findings suggest that "screen and treat" policies alone are unlikely to have substantial impact on the worsening epidemic of type 2 diabetes. PROSPERO (No CRD42016042920). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Etminan-Bakhsh, Mina; Tadi, Sima; Darabi, Roksana
2017-11-01
Asymptomatic bacteriuria is one of the common problems in pregnancy. Asymptomatic bacteriuria is associated with pyelonephritis, preterm labor and low birth weight infants. The physiological and anatomical changes in pregnancy facilitate urinary tract infection (UTI) during pregnancy. Several tests are available for diagnosis of asymptomatic bacteriuria. The urine culture is a gold standard diagnostic test for asymptomatic bacteriuria but it is expensive and time-consuming. Screening methods may be useful in detecting high-risk pregnant women for asymptomatic bacteriuria. The aim of the present study was to compare urine analysis as a rapid screening test to urine culture in diagnosis of asymptomatic bacteriuria. A total of 123 pregnant women attending the obstetrics clinic of Boo-Ali hospital in Tehran, Iran from March 2013 to September 2014 were included in the present diagnostic cross-sectional study. One hundred twenty three mid-stream urine samples were inoculated into cultures and were processed by dipstick (nitrite test and leucocyte esterase test) and microscopic pus cell count. The sensitivity, specificity, positive predictive value and negative predictive value of nitrite test, leucocyte esterase test and microscopic pus cell count were compared with urine culture in diagnosis of asymptomatic bacteriuria by using SPSS version 19. Of 123 urine samples, significant asymptomatic bacteriuria (≥10 4 cfu/Ml) was detected in 8 (6.5%) subjects. The sensitivity and specificity of nitrite test were 37% and 100% respectively. The sensitivity of pus cell count alone and leucocyte esterase test alone were 100% but the specificity of them were 64% and 65% respectively. We found high negative predictive value by Pus cell count and the leucocyte esterase test (100%) and low positive predictive value by them (16% and 17% respectively). Urine culture is the most useful test for diagnosis of asymptomatic bacteriuria. None of our screening tests had a sensitivity and specificity of 100%, whereas we can only refer the pregnant women with positive leucocyte esterase test and significant pyuria to the urine culture.
Screening for tuberculosis and testing for human immunodeficiency virus in Zambian prisons
Maggard, Katie R; Hatwiinda, Sisa; Harris, Jennifer B; Phiri, Winifreda; Krüüner, Annika; Kaunda, Kaunda; Topp, Stephanie M; Kapata, Nathan; Ayles, Helen; Chileshe, Chisela; Henostroza, German
2015-01-01
Abstract Objective To improve the Zambia Prisons Service’s implementation of tuberculosis screening and human immunodeficiency virus (HIV) testing. Methods For both tuberculosis and HIV, we implemented mass screening of inmates and community-based screening of those residing in encampments adjacent to prisons. We also established routine systems – with inmates as peer educators – for the screening of newly entered or symptomatic inmates. We improved infection control measures, increased diagnostic capacity and promoted awareness of tuberculosis in Zambia’s prisons. Findings In a period of 9 months, we screened 7638 individuals and diagnosed 409 new patients with tuberculosis. We tested 4879 individuals for HIV and diagnosed 564 cases of infection. An additional 625 individuals had previously been found to be HIV-positive. Including those already on tuberculosis treatment at the time of screening, the prevalence of tuberculosis recorded in the prisons and adjacent encampments – 6.4% (6428/100 000) – is 18 times the national prevalence estimate of 0.35%. Overall, 22.9% of the inmates and 13.8% of the encampment residents were HIV-positive. Conclusion Both tuberculosis and HIV infection are common within Zambian prisons. We enhanced tuberculosis screening and improved the detection of tuberculosis and HIV in this setting. Our observations should be useful in the development of prison-based programmes for tuberculosis and HIV elsewhere. PMID:25883402
Nshimyumukiza, L; Menon, S; Hina, H; Rousseau, F; Reinharz, D
2018-07-01
Although noninvasive prenatal testing (NIPT) for aneuploidies using cell-free fetal DNA in maternal blood has been reported to have a high accuracy, only little evidence about its cost-effectiveness is available. We systematically reviewed and assessed quality of economic evaluation studies published between January 1, 2009 and January 1, 2016 where NIPT was compared to the current screening practices consisting of biochemical markers with or without nuchal translucency (NT) and/or maternal age. We included 16 studies and we found that, at current level of NIPT prices, contingent NIPT provide the best value for money, especially for publicly funded screening programs. NIPT as first-line test was found not cost-effective in the majority of studies. The NIPT unit cost, the risk cut-offs for current screening practice, the screening uptake rates (first- and second-line screening) as well as the costs and uptake rates of invasive diagnostic screening were the most common uncertain variables. The overall quality of included studies was fair. Considering a possible drop in prices and an ongoing NIPT expansion to include other chromosomes abnormalities other than T21, T18, T13 and sex chromosomes aneuploidies, future research are needed to examine the potential cost-effectiveness of implementing NIPT as first-line test. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Rex, Douglas K; Boland, C Richard; Dominitz, Jason A; Giardiello, Francis M; Johnson, David A; Kaltenbach, Tonya; Levin, Theodore R; Lieberman, David; Robertson, Douglas J
2017-07-01
This document updates the colorectal cancer (CRC) screening recommendations of the U.S. Multi-Society Task Force of Colorectal Cancer (MSTF), which represents the American College of Gastroenterology, the American Gastroenterological Association, and The American Society for Gastrointestinal Endoscopy. CRC screening tests are ranked in 3 tiers based on performance features, costs, and practical considerations. The first-tier tests are colonoscopy every 10 years and annual fecal immunochemical test (FIT). Colonoscopy and FIT are recommended as the cornerstones of screening regardless of how screening is offered. Thus, in a sequential approach based on colonoscopy offered first, FIT should be offered to patients who decline colonoscopy. Colonoscopy and FIT are recommended as tests of choice when multiple options are presented as alternatives. A risk-stratified approach is also appropriate, with FIT screening in populations with an estimated low prevalence of advanced neoplasia and colonoscopy screening in high prevalence populations. The second-tier tests include CT colonography every 5 years, the FIT-fecal DNA test every 3 years, and flexible sigmoidoscopy every 5 to 10 years. These tests are appropriate screening tests, but each has disadvantages relative to the tier 1 tests. Because of limited evidence and current obstacles to use, capsule colonoscopy every 5 years is a third-tier test. We suggest that the Septin9 serum assay (Epigenomics, Seattle, Wash) not be used for screening. Screening should begin at age 50 years in average-risk persons, except in African Americans in whom limited evidence supports screening at 45 years. CRC incidence is rising in persons under age 50, and thorough diagnostic evaluation of young persons with suspected colorectal bleeding is recommended. Discontinuation of screening should be considered when persons up to date with screening, who have prior negative screening (particularly colonoscopy), reach age 75 or have <10 years of life expectancy. Persons without prior screening should be considered for screening up to age 85, depending on age and comorbidities. Persons with a family history of CRC or a documented advanced adenoma in a first-degree relative age <60 years or 2 first-degree relatives with these findings at any age are recommended to undergo screening by colonoscopy every 5 years, beginning 10 years before the age at diagnosis of the youngest affected relative or age 40, whichever is earlier. Persons with a single first-degree relative diagnosed at ≥60 years with CRC or an advanced adenoma can be offered average-risk screening options beginning at age 40 years.
Cardona-Arias, Jaiberth Antonio; Carrasquilla-Agudelo, Yoneida Elena; Restrepo-Posada, Deisy Cristina
2017-02-01
The screening of neurocysticercosis is complex and immunological methods have varying validity. To evaluate the validity of ELISA for antigen and antibody, and EITB for antibody in the screening of neurocysticercosis. Meta-analysis of diagnostic tests with an ex-ante protocol implemented in five databases with 15 search strategies, ensuring reproducibility in the selection and extraction of information. Sensitivity, specificity, likelihood ratios (LR), diagnostic odds ratio and ROC curve were estimated in MetaDiSc, and predictive values, and Youden index were estimated in Epidat. EITB presented sensitivity of 85.7% (95% CI 83.5-87.7), specificity 93.9% (95% CI = 92.7-95.0), PLR 19.6 (95% CI = 8,6-44.6), NLR 0.16 (95% CI = 0.12-0.21), OR diagnostic 136.2 (95% CI = 54.7-342.6) and area under the curve 0.926. In ELISA for antibody sensitivity was 87.5% (95% CI = 86.1-88.8), specificity 92.2% (95% CI = 91.4-93.0), PLR 11.3 (95% CI = 8.45-15.11), NLR 0.15 (95% CI = 0.13-0.18), diagnostic OR 87.4 (95% CI = 60.1-127.1) and area under the curve 0.950. ELISA for antigen showed low diagnostic validity. No differences were found in these parameters by sample, antigen or antibody type. ELISA for antibodies and EITB have a similar diagnostic value, detection of serum and CSF showed a similar validity.
Towards a systematic nationwide screening strategy for MODY.
Shields, Beverley; Colclough, Kevin
2017-04-01
MODY is an early-onset monogenic form of diabetes. Correctly identifying MODY is of considerable importance as diagnosing the specific genetic subtype can inform the optimal treatment, with many patients being able to discontinue unnecessary insulin treatment. Diagnostic molecular genetic testing to confirm MODY is expensive, so screening strategies are required to identify the most appropriate patients for testing. In this issue of Diabetologia, Johansson and colleagues (DOI 10.1007/s00125-016-4167-1 ) describe a nationwide systematic screening approach to identify individuals with MODY in the paediatric age range. They focused testing on patients negative for both GAD and islet antigen 2 (IA-2) islet autoantibodies, thereby ruling out those with markers of type 1 diabetes, the most common form of diabetes in this age group. This commentary discusses the advantages and limitations of the approach, and the caution required when interpreting variants of uncertain pathogenicity identified from testing whole populations rather than targeting only patients with a strong MODY phenotype.
Johnson, Susan L; Tabaei, Bahman P; Herman, William H
2005-02-01
To simulate the outcomes of alternative strategies for screening the U.S. population 45-74 years of age for type 2 diabetes. We simulated screening with random plasma glucose (RPG) and cut points of 100, 130, and 160 mg/dl and a multivariate equation including RPG and other variables. Over 15 years, we simulated screening at intervals of 1, 3, and 5 years. All positive screening tests were followed by a diagnostic fasting plasma glucose or an oral glucose tolerance test. Outcomes include the numbers of false-negative, true-positive, and false-positive screening tests and the direct and indirect costs. At year 15, screening every 3 years with an RPG cut point of 100 mg/dl left 0.2 million false negatives, an RPG of 130 mg/dl or the equation left 1.3 million false negatives, and an RPG of 160 mg/dl left 2.8 million false negatives. Over 15 years, the absolute difference between the most sensitive and most specific screening strategy was 4.5 million true positives and 476 million false-positives. Strategies using RPG cut points of 130 mg/dl or the multivariate equation every 3 years identified 17.3 million true positives; however, the equation identified fewer false-positives. The total cost of the most sensitive screening strategy was $42.7 billion and that of the most specific strategy was $6.9 billion. Screening for type 2 diabetes every 3 years with an RPG cut point of 130 mg/dl or the multivariate equation provides good yield and minimizes false-positive screening tests and costs.
Point-of-care urine tests for smoking status and isoniazid treatment monitoring in adult patients.
Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar
2012-01-01
Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference.
Point-of-Care Urine Tests for Smoking Status and Isoniazid Treatment Monitoring in Adult Patients
Nicolau, Ioana; Tian, Lulu; Menzies, Dick; Ostiguy, Gaston; Pai, Madhukar
2012-01-01
Background Poor adherence to isoniazid (INH) preventive therapy (IPT) is an impediment to effective control of latent tuberculosis (TB) infection. TB patients who smoke are at higher risk of latent TB infection, active disease, and TB mortality, and may have lower adherence to their TB medications. The objective of our study was to validate IsoScreen and SmokeScreen (GFC Diagnostics, UK), two point-of-care tests for monitoring INH intake and determining smoking status. The tests could be used together in the same individual to help identify patients with a high-risk profile and provide a tailored treatment plan that includes medication management, adherence interventions, and smoking cessation programs. Methodology/Principal Findings 200 adult outpatients attending the TB and/or the smoking cessation clinic were recruited at the Montreal Chest Institute. Sensitivity and specificity were measured for each test against the corresponding composite reference standard. Test reliability was measured using kappa statistic for intra-rater and inter-rater agreement. Univariate and multivariate logistic regression models were used to explore possible covariates that might be related to false-positive and false-negative test results. IsoScreen had a sensitivity of 93.2% (95% confidence interval [CI] 80.3, 98.2) and specificity of 98.7% (94.8, 99.8). IsoScreen had intra-rater agreement (kappa) of 0.75 (0.48, 0.94) and inter-rater agreement of 0.61 (0.27, 0.90). SmokeScreen had a sensitivity of 69.2% (56.4, 79.8), specificity of 81.6% (73.0, 88.0), intra-rater agreement of 0.77 (0.56, 0.94), and inter-rater agreement of 0.66 (0.42, 0.88). False-positive SmokeScreen tests were strongly associated with INH treatment. Conclusions IsoScreen had high validity and reliability, whereas SmokeScreen had modest validity and reliability. SmokeScreen tests did not perform well in a population receiving INH due to the association between INH treatment and false-positive SmokeScreen test results. Development of the next generation SmokeScreen assay should account for this potential interference. PMID:23029310
Bisser, Sylvie; Lumbala, Crispin; Nguertoum, Etienne; Kande, Victor; Flevaud, Laurence; Vatunga, Gedeao; Boelaert, Marleen; Büscher, Philippe; Josenando, Theophile; Bessell, Paul R; Biéler, Sylvain; Ndung'u, Joseph M
2016-04-01
A major challenge in the control of human African trypanosomiasis (HAT) is lack of reliable diagnostic tests that are rapid and easy to use in remote areas where the disease occurs. In Trypanosoma brucei gambiense HAT, the Card Agglutination Test for Trypanosomiasis (CATT) has been the reference screening test since 1978, usually on whole blood, but also in a 1/8 dilution (CATT 1/8) to enhance specificity. However, the CATT is not available in a single format, requires a cold chain for storage, and uses equipment that requires electricity. A solution to these challenges has been provided by rapid diagnostic tests (RDT), which have recently become available. A prototype immunochromatographic test, the SD BIOLINE HAT, based on two native trypanosomal antigens (VSG LiTat 1.3 and VSG LiTat 1.5) has been developed. We carried out a non-inferiority study comparing this prototype to the CATT 1/8 in field settings. The prototype SD BIOLINE HAT, the CATT Whole Blood and CATT 1/8 were systematically applied on fresh blood samples obtained from 14,818 subjects, who were prospectively enrolled through active and passive screening in clinical studies in three endemic countries of central Africa: Angola, the Democratic Republic of the Congo and the Central African Republic. One hundred and forty nine HAT cases were confirmed by parasitology. The sensitivity and specificity of the prototype SD BIOLINE HAT was 89.26% (95% confidence interval (CI) = 83.27-93.28) and 94.58% (95% CI = 94.20-94.94) respectively. The sensitivity and specificity of the CATT on whole blood were 93.96% (95% CI = 88.92-96.79) and 95.91% (95% CI = 95.58-96.22), and of the CATT 1/8 were 89.26% (95% CI = 83.27-93.28) and 98.88% (95% CI = 98.70-99.04) respectively. After further optimization, the prototype SD BIOLINE HAT could become an alternative to current screening methods in primary healthcare settings in remote, resource-limited regions where HAT typically occurs.
Larner, A J
2016-01-01
Calculation of correlation coefficients is often undertaken as a way of comparing different cognitive screening instruments (CSIs). However, test scores may correlate but not agree, and high correlation may mask lack of agreement between scores. The aim of this study was to use the methodology of Bland and Altman to calculate limits of agreement between the scores of selected CSIs and contrast the findings with Pearson's product moment correlation coefficients between the test scores of the same instruments. Datasets from three pragmatic diagnostic accuracy studies which examined the Mini-Mental State Examination (MMSE) vs. the Montreal Cognitive Assessment (MoCA), the MMSE vs. the Mini-Addenbrooke's Cognitive Examination (M-ACE), and the M-ACE vs. the MoCA were analysed to calculate correlation coefficients and limits of agreement between test scores. Although test scores were highly correlated (all >0.8), calculated limits of agreement were broad (all >10 points), and in one case, MMSE vs. M-ACE, was >15 points. Correlation is not agreement. Highly correlated test scores may conceal broad limits of agreement, consistent with the different emphases of different tests with respect to the cognitive domains examined. Routine incorporation of limits of agreement into diagnostic accuracy studies which compare different tests merits consideration, to enable clinicians to judge whether or not their agreement is close. © 2016 S. Karger AG, Basel.
Ho, Jennifer; Nguyen, Phuong Thi Bich; Nguyen, Thu Anh; Tran, Khoa Hien; Van Nguyen, Son; Nguyen, Nhung Viet; Nguyen, Hoa Binh; Luu, Khanh Boi; Fox, Greg J; Marks, Guy B
2016-09-01
Community-wide screening for tuberculosis with Xpert MTB/RIF as a primary screening tool overcomes some of the limitations of conventional screening. However, concerns exist about the low positive predictive value of this test in screening settings. We did a cross-sectional assessment of this diagnostic test to directly estimate the actual positive predictive value of Xpert MTB/RIF when used in the setting of community-wide screening for tuberculosis, and to draw an inference about the specificity of the test for tuberculosis detection. Field staff visited households in 60 randomly selected villages in Ca Mau province, Vietnam. We included people aged 15 years or older who provided written informed consent and were able to produce 0·5 mL or more of sputum, irrespective of reported symptoms. Participants were tested with Xpert MTB/RIF, then those with positive results had two further sputum samples tested for smear microscopy and culture, and underwent chest radiography at the provincial TB Health Center. The positive predictive value of Xpert MTB/RIF was compared against two reference standards for tuberculosis diagnosis-a positive sputum culture for Mycobacterium tuberculosis, and a positive sputum culture or a chest radiograph consistent with active pulmonary tuberculosis. We then calculated the specificity of Xpert MTB/RIF for tuberculosis detection on the basis of these positive predictive values and disease prevalence in this setting. 43 435 adults consented to screening with Xpert MTB/RIF. Sputum samples of 0·5 mL or greater were collected from 23 202 participants, producing 22 673 valid results. 169 participants had positive Xpert MTB/RIF results (0·39% of those screened and 0·75% of those with valid sputum results). The positive predictive value of Xpert MTB/RIF was 61·0% (95% CI 52·8-68·7) when compared against a positive sputum culture and 83·9% (76·8-89·2) when compared against a positive sputum culture or chest radiograph consistent with active tuberculosis. On the basis of these positive predictive values, the specificity of Xpert MTB/RIF was determined to be between 99·78% (95% CI 99·71-99·84) and 99·93% (99·88-99·96). The positive predictive value and specificity of Xpert MTB/RIF in the context of community-wide screening for tuberculosis is substantially higher than that predicted in previous studies. Our findings support the potential role of Xpert MTB/RIF as a primary screening tool to detect prevalent cases of tuberculosis in the community. Australian National Health and Medical Research Council. Copyright © 2016 Elsevier Ltd. All rights reserved.
The role of neurologists and diagnostic tests in the management of distal symmetric polyneuropathy
Callaghan, Brian C.; Kerber, Kevin A.; Lisabeth, Lynda L.; Morgenstern, Lewis B.; Longoria, Ruth; Rodgers, Ann; Longwell, Paxton; Feldman, Eva L.
2014-01-01
Importance Distal symmetric polyneuropathy (DSP) is a prevalent condition resulting in high costs from diagnostic testing. However, the role of neurologists and diagnostic tests on patient care is unknown. Objective To determine how often neurologists and diagnostic tests influence the diagnosis and management of DSP patients in a community setting. Design We utilized a validated case-capture method (ICD-9 screening technique with subsequent medical chart abstraction) to identify patients with a new DSP diagnosis (retrospective cohort). Using a structured data abstraction process, diagnostic testing, diagnoses rendered (before and after testing), and subsequent management were recorded. Setting Community neurologist’s outpatient offices in Corpus Christi, Texas. Participants Patients meeting the Toronto consensus criteria for probable DSP. Main Outcome Measure Changes in etiology and management after diagnostic testing by neurologists. Results Between 1/1/2010–3/31/2011, we identified 458 DSP patients followed for mean (SD) 435.3 (44.1) days. Neurologists identified a cause of DSP in 63.5% of cases prior to their diagnostic testing. Seventy-one patients (15.5%) had a new DSP cause discovered after testing by neurologists. The most common new diagnoses were pre-diabetes (N=28), B12 deficiency (N=20), diabetes (N=8), and thyroid disease (N=8). Management changes were common (63.1%), usually related to neuropathic pain management (77.5%). Disease modifying management changes occurred in 24.7% with diabetes management (N=45), starting vitamins (N=39), advising diet/exercise (N=33), and adjusting thyroid medications (N=10) the most common. Electrodiagnostic testing and MRIs of the neuroaxis rarely led to management changes. Conclusions and Relevance Neurologists diagnosed the cause of DSP in almost two-thirds of patients prior to their diagnostic testing. Inexpensive blood tests for diabetes, thyroid dysfunction, and B12 deficiency, allowed neurologists to identify a new etiology in 15.5% of patients. In contrast, expensive electrodiagnostic tests and MRIs rarely changed patient care. Neurologists also frequently made pain medication changes utilizing best evidence medications. PMID:25048157
Morgan, Marjorie S.; Rider, S. Dean; Arlian, Larry G.
2017-01-01
Background Scabies, caused by the mite, Sarcoptes scabiei, infects millions of humans, and many wild and domestic mammals. Scabies mites burrow in the lower stratum corneum of the epidermis of the skin and are the source of substances that are antigenic or modulate aspects of the protective response of the host. Ordinary scabies is a difficult disease to diagnose. Objective The goal of this project was to identify S. scabiei proteins that may be candidate antigens for use in a diagnostic test or may be used by the mite to modulate the host’s protective response. Methods An aqueous extract of S. scabiei was separated by 2-dimensional electrophoresis and proteins were identified by mass spectrometry. A parallel immunoblot was probed with serum from patients with ordinary scabies to identify IgM and/or IgG-binding antigens. The genes coding for 23 selected proteins were cloned into E. coli and the expressed recombinant proteins were screened with serum from patients with confirmed ordinary scabies. Results We identified 50 different proteins produced by S. scabiei, 34 of which were not previously identified, and determined that 66% were recognized by patient IgM and/or IgG. Fourteen proteins were screened for use in a diagnostic test but none possessed enough sensitivity and specificity to be useful. Six of the 9 proteins selected for the possibility that they may be immunomodulatory were not recognized by antibodies in patient serum. Conclusions Thirty-three proteins that bound IgM and/or IgG from the serum of patients with ordinary scabies were identified. None of the 14 tested were useful for inclusion in a diagnostic test. The identities of 16 proteins that are not recognized as antigens by infected patients were also determined. These could be among the molecules that are responsible for this mite’s ability to modulate its host’s innate and adaptive immune responses. PMID:28604804
Chang, Ming; Wong, Audrey J S; Raugi, Dana N; Smith, Robert A; Seilie, Annette M; Ortega, Jose P; Bogusz, Kyle M; Sall, Fatima; Ba, Selly; Seydi, Moussa; Gottlieb, Geoffrey S; Coombs, Robert W
2017-01-01
The 2014 CDC 4th generation HIV screening algorithm includes an orthogonal immunoassay to confirm and discriminate HIV-1 and HIV-2 antibodies. Additional nucleic acid testing (NAT) is recommended to resolve indeterminate or undifferentiated HIV seroreactivity. HIV-2 NAT requires a second-line assay to detect HIV-2 total nucleic acid (TNA) in patients' blood cells, as a third of untreated patients have undetectable plasma HIV-2 RNA. To validate a qualitative HIV-2 TNA assay using peripheral blood mononuclear cells (PBMC) from HIV-2-infected Senegalese study participants. We evaluated the assay precision, sensitivity, specificity, and diagnostic performance of an HIV-2 TNA assay. Matched plasma and PBMC samples were collected from 25 HIV-1, 30 HIV-2, 8 HIV-1/-2 dual-seropositive and 25 HIV seronegative individuals. Diagnostic performance was evaluated by comparing the outcome of the TNA assay to the results obtained by the 4th generation HIV screening and confirmatory immunoassays. All PBMC from 30 HIV-2 seropositive participants tested positive for HIV-2 TNA including 23 patients with undetectable plasma RNA. Of the 30 matched plasma specimens, one was HIV non-reactive. Samples from 50 non-HIV-2 infected individuals were confirmed as non-reactive for HIV-2 Ab and negative for HIV-2 TNA. The agreement between HIV-2 TNA and the combined immunoassay results was 98.8% (79/80). Furthermore, HIV-2 TNA was detected in 7 of 8 PBMC specimens from HIV-1/HIV-2 dual-seropositive participants. Our TNA assay detected HIV-2 DNA/RNA in PBMC from serologically HIV-2 reactive, HIV indeterminate or HIV undifferentiated individuals with undetectable plasma RNA, and is suitable for confirming HIV-2 infection in the HIV testing algorithm. Copyright © 2016 Elsevier B.V. All rights reserved.
De Souza, Mark S; Phanuphak, Nittaya; Pinyakorn, Suteeraporn; Trichavaroj, Rapee; Pattanachaiwit, Supanit; Chomchey, Nitiya; Fletcher, James L; Kroon, Eugene D; Michael, Nelson L; Phanuphak, Praphan; Kim, Jerome H; Ananworanich, Jintanat
2015-04-24
To assess the addition of HIV nucleic acid testing (NAT) to fourth-generation (4thG) HIV antigen/antibody combination immunoassay in improving detection of acute HIV infection (AHI). Participants attending a major voluntary counseling and testing site in Thailand were screened for AHI using 4thG HIV antigen/antibody immunoassay and sequential less sensitive HIV antibody immunoassay. Samples nonreactive by 4thG antigen/antibody immunoassay were further screened using pooled NAT to identify additional AHI. HIV infection status was verified following enrollment into an AHI study with follow-up visits and additional diagnostic tests. Among 74 334 clients screened for HIV infection, HIV prevalence was 10.9% and the overall incidence of AHI (N = 112) was 2.2 per 100 person-years. The inclusion of pooled NAT in the testing algorithm increased the number of acutely infected patients detected, from 81 to 112 (38%), relative to 4thG HIV antigen/antibody immunoassay. Follow-up testing within 5 days of screening marginally improved the 4thG immunoassay detection rate (26%). The median CD4 T-cell count at the enrollment visit was 353 cells/μl and HIV plasma viral load was 598 289 copies/ml. The incorporation of pooled NAT into the HIV testing algorithm in high-risk populations may be beneficial in the long term. The addition of pooled NAT testing resulted in an increase in screening costs of 22% to identify AHI: from $8.33 per screened patient to $10.16. Risk factors of the testing population should be considered prior to NAT implementation given the additional testing complexity and costs.
Critical Discussion of Essentials of Diagnosis and Recording in Periodontics.
ERIC Educational Resources Information Center
Ellen, Richard P.
1994-01-01
Issues to be addressed before writing standards of care for the diagnosis of adult periodontal disease are discussed. These include considerations in screening and examination; arriving at diagnosis and prognosis, informing the patient, and referral; monitoring outcomes using diagnostic signs and tests; and new technology for and approaches to…
Miller, Jacqueline W.; Hanson, Vivien; Johnson, Gale D.; Royalty, Janet E.; Richardson, Lisa C.
2015-01-01
The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) provides breast and cervical cancer screening and diagnostic services to low-income and underserved women through a network of providers and health care organizations. Although the program serves women 40-64 years old for breast cancer screening and 21-64 years old for cervical cancer screening, the priority populations are women 50-64 years old for breast cancer and women who have never or rarely been screened for cervical cancer. From 1991 through 2011, the NBCCEDP provided screening and diagnostic services to more than 4.3 million women, diagnosing 54,276 breast cancers, 2554 cervical cancers, and 123,563 precancerous cervical lesions. A critical component of providing screening services is to ensure that all women with abnormal screening results receive appropriate and timely diagnostic evaluations. Case management is provided to assist women with overcoming barriers that would delay or prevent follow-up care. Women diagnosed with cancer receive treatment through the states' Breast and Cervical Cancer Treatment Programs (a special waiver for Medicaid) if they are eligible. The NBCCEDP has performance measures that serve as benchmarks to monitor the completeness and timeliness of care. More than 90% of the women receive complete diagnostic care and initiate treatment less than 30 days from the time of their diagnosis. Provision of effective screening and diagnostic services depends on effective program management, networks of providers throughout the community, and the use of evidence-based knowledge, procedures, and technologies. PMID:25099897
Kim, Jane J.; Campos, Nicole G.; Sy, Stephen; Burger, Emily A.; Cuzick, Jack; Castle, Philip E.; Hunt, William C.; Waxman, Alan; Wheeler, Cosette M.
2016-01-01
Background Studies suggest that cervical cancer screening practice in the United States is inefficient. The cost and health implications of non-compliance in the screening process compared to recommended guidelines are uncertain. Objective To estimate the benefits, costs, and cost-effectiveness of current cervical cancer screening practice and assess the value of screening improvements. Design Model-based cost-effectiveness analysis. Data Sources New Mexico HPV Pap Registry; medical literature. Target Population Cohort of women eligible for routine screening. Time Horizon Lifetime. Perspective Societal. Interventions Current cervical cancer screening practice; improved compliance to guidelines-based screening interval, triage testing, diagnostic referrals, and precancer treatment referrals. Outcome Measures Reductions in lifetime cervical cancer risk, quality-adjusted life-years (QALYs), lifetime costs, incremental cost-effectiveness ratios (ICERs), incremental net monetary benefits (INMBs Results of Base-Case Analysis Current screening practice was associated with lower health benefit and was not cost-effective relative to guidelines-based strategies. Improvements in the screening process were associated with higher QALYs and small changes in costs. Perfect c4mpliance to a 3-yearly screening interval and to colposcopy/biopsy referrals were associated with the highest INMBs ($759 and $741, respectively, at a willingness-to-pay threshold of $100,000 per QALY gained); together, the INMB increased to $1,645. Results of Sensitivity Analysis Current screening practice was inefficient in 100% of simulations. The rank ordering of screening improvements according to INMBs was stable over a range of screening inputs and willingness-to-pay thresholds. Limitations The impact of HPV vaccination was not considered. Conclusions The added health benefit of improving compliance to guidelines, especially the 3-yearly interval for cytology screening and diagnostic follow-up, may justify additional investments in interventions to improve U.S. cervical cancer screening practice. Funding Source U.S. National Cancer Institute. PMID:26414147
Kusters, Elske; Kerkhoffs, Jean-Louis H; van Rossum, André P
2014-01-01
The thalassaemias are characterised by quantitative aberrations in the production of the globin chains that make up haemoglobin, and are a subgroup of the haemoglobinopathies. In this LabQuiz we show how thalassaemia carrier status can be indicated in the results of regular laboratory tests, and discuss the laboratory diagnostics that can confirm or rule out thalassaemia. In these two cases we will present a man of Moroccan descent, and two brothers of Filipino descent, all with anaemia and microcytosis. We show it is possible to differentiate between iron-deficiency anaemia and thalassaemia carrier status on the basis of a complete blood count and measurement of ferritin levels, and which laboratory diagnostics can be subsequently performed in order to confirm a suspicion of thalassaemia. The background section discusses the properties and pitfalls of routine laboratory diagnostics for the thalassaemias, and thalassaemia diagnostics in the Dutch newborn screening programme.
Magyar, Caroline I; Pandolfi, Vincent; Dill, Charles A
2012-02-01
This study investigated the psychometric properties of the Social Communication Questionnaire (SCQ) in a sample of children with Down syndrome (DS), many of whom had a co-occurring autism spectrum disorder (ASD). The SCQ is a widely used ASD screening measure; however, its measurement properties have not been comprehensively evaluated specifically in children with DS, a group that seems to be at higher risk for an ASD. Exploratory and confirmatory factor analyses, scale reliability, convergent and discriminant correlations, significance tests between groups of children with DS and DS + ASD, and diagnostic accuracy analyses were conducted. Factor analyses identified 2 reliable factors that we labeled Social-Communication and Stereotyped Behavior and Unusual Interests. Pearson correlations with Autism Diagnostic Interview-Revised subscales indicated support for the SCQ's convergent validity and some support for the discriminant validity of the factor-based scales. Significance tests and receiver operating characteristic analyses indicated that children with DS + ASD obtained significantly higher SCQ factor-based and total scores than children with DS alone, and that the SCQ Total Score evidenced good sensitivity and adequate specificity. Results indicated initial psychometric support for the SCQ as an ASD screening measure in children with DS. The SCQ should be considered as part of a multimethod evaluation when screening children with DS.
Detection of scabies: A systematic review of diagnostic methods
Leung, Victor; Miller, Mark
2011-01-01
BACKGROUND: Accurate diagnosis of scabies infection is important for patient treatment and for public health control of scabies epidemics. OBJECTIVE: To systematically review the accuracy and precision of history, physical examination and tests for diagnosing scabies. METHODS: Using a structured search strategy, Medline and Embase databases were searched for English and French language articles that included a diagnosis of scabies. Studies comparing history, physical examination and/or any diagnostic tests with the reference standard of microscopic visualization of mites, eggs or fecal elements obtained from skin scrapings or biopsies were included for analysis. Data were extracted using standard criteria. RESULTS: History and examination of pruritic dermatoses failed to accurately diagnose scabies infection. Dermatoscopy by a trained practitioner has a positive likelihood ratio of 6.5 (95% CI 4.1 to 10.3) and a negative likelihood ratio of 0.1 (95% CI 0.06 to 0.2) for diagnosing scabies. The accuracy of other diagnostic tests could not be calculated from the data in the literature. CONCLUSIONS: In the face of such diagnostic inaccuracy, clinical judgment is still practical in diagnosing scabies. Two tests are used – the burrow ink test and handheld dermatoscopy. The burrow ink test is a simple, rapid, noninvasive test that can be used to screen a large number of patients. Handheld dermatoscopy is an accurate test, but requires special equipment and trained practitioners. Given the morbidity and costs of scabies infection, and that studies to date lack adequate internal and external validity, research to identify or develop accurate diagnostic tests for scabies infection is needed and justifiable. PMID:23205026
Detection of scabies: A systematic review of diagnostic methods.
Leung, Victor; Miller, Mark
2011-01-01
Accurate diagnosis of scabies infection is important for patient treatment and for public health control of scabies epidemics. To systematically review the accuracy and precision of history, physical examination and tests for diagnosing scabies. Using a structured search strategy, Medline and Embase databases were searched for English and French language articles that included a diagnosis of scabies. Studies comparing history, physical examination and/or any diagnostic tests with the reference standard of microscopic visualization of mites, eggs or fecal elements obtained from skin scrapings or biopsies were included for analysis. Data were extracted using standard criteria. History and examination of pruritic dermatoses failed to accurately diagnose scabies infection. Dermatoscopy by a trained practitioner has a positive likelihood ratio of 6.5 (95% CI 4.1 to 10.3) and a negative likelihood ratio of 0.1 (95% CI 0.06 to 0.2) for diagnosing scabies. The accuracy of other diagnostic tests could not be calculated from the data in the literature. In the face of such diagnostic inaccuracy, clinical judgment is still practical in diagnosing scabies. Two tests are used - the burrow ink test and handheld dermatoscopy. The burrow ink test is a simple, rapid, noninvasive test that can be used to screen a large number of patients. Handheld dermatoscopy is an accurate test, but requires special equipment and trained practitioners. Given the morbidity and costs of scabies infection, and that studies to date lack adequate internal and external validity, research to identify or develop accurate diagnostic tests for scabies infection is needed and justifiable.
Katz, Lior H.; Burton-Chase, Allison M.; Advani, Shailesh; Fellman, Bryan; Polivka, Katrina M.; Yuan, Ying; Lynch, Patrick M.; Peterson, Susan K.
2016-01-01
Background Cancer screening recommendations for patients with Lynch-like syndrome (LLS) are not well defined. We evaluated adherence to Lynch syndrome (LS) screening recommendations, cancer risk perceptions, and communication within the families among colorectal cancer (CRC) survivors with LLS. Methods Thirty-four participants with LLS completed a questionnaire about risk perception, adherence to LS screening recommendations, and communication with relatives. Clinical data were obtained from medical records. Results Most participants (76%) believed they should undergo colonoscopy every 1-2 years. Only 41% correctly interpreted their genetic tests as uninformative negative or as variant of unknown significance for LS. Less than half had had an upper GI endoscopy for screening purpose. Among female participants, 86% had been screened for endometrial cancer and 71% for ovarian cancer. Most participants had informed relatives about the CRC diagnosis and advised them to undergo CRC screening, but only 50% advised female relatives to be screened for endometrial cancer and only one-third advised relatives to have genetic counseling. Conclusions Most CRC survivors with LLS follow the same cancer screening recommended for LS patients but do not understand the meaning of LLS. Greater care must be devoted to communicating the implications of non-diagnostic germline mutation testing among patients with LLS. PMID:26272410
Computer-aided testing of pilot response to critical in-flight events
NASA Technical Reports Server (NTRS)
Giffin, W. C.; Rockwell, T. H.
1984-01-01
This research on pilot response to critical in-flight events employs a unique methodology including an interactive computer-aided scenario-testing system. Navigation displays, instrument-panel displays, and assorted textual material are presented on a touch-sensitive CRT screen. Problem diagnosis scenarios, destination-diversion scenarios and combined destination/diagnostic tests are available. A complete time history of all data inquiries and responses is maintained. Sample results of diagnosis scenarios obtained from testing 38 licensed pilots are presented and discussed.
Evaluation of 9 rapid diagnostic tests for screening HIV infection, in Lomé, Togo.
Dagnra, A Y; Dossim, S; Salou, M; Nyasenu, T; Ali-Edje, K; Ouro-Médeli, A; Doufan, M; Ehlan, A; Prince-David, M
2014-12-01
HIV rapid diagnostic tests (RDT) could be greatly contributive for a universal access to HIV diagnosis. However, according to the WHO, these tests need to be assessed before they can be used in routine. We assessed 9 RDT in routine clinical use between 2009 and 2013. The sensitivity and specificity observed for 7 tests were≥99% and≥98%, respectively: FIRST RESPONSE HIV1-2-O PMC Medical, India, GENIE Fast HIV 1-2 and GENIE™ III HIV(1/2) Bio-Rad, France, HIV TRI-DOT+Ag;J. Mitra, INDIA; SD BIOLINE HIV(1/2) 3.0 and SD BIOLINE HIV/SYPHILIS DUO Standard Diagnostic, Korea; and VIKIA HIV(1/2); BioMérieux, France. Two tests had performances inferior to WHO recommendations: INSTI HIV1/2 Biolytical Canada; sensitivity=97.8% and HEXAGON HIV HUMAN GmbH Germany; specificity=94.8%. Seven of 9 RDT had excellent performances. Nevertheless, they can be used only after training staff, and taking into account national algorithm for their safe use. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Basehore, Monica J; Marlowe, Natalia M; Jones, Julie R; Behlendorf, Deborah E; Laver, Thomas A; Friez, Michael J
2012-06-01
Most individuals with intellectual disability and/or autism are tested for Fragile X syndrome at some point in their lifetime. Greater than 99% of individuals with Fragile X have an expanded CGG trinucleotide repeat motif in the promoter region of the FMR1 gene, and diagnostic testing involves determining the size of the CGG repeat as well as methylation status when an expansion is present. Using a previously described triplet repeat-primed polymerase chain reaction, we have performed additional validation studies using two cohorts with previous diagnostic testing results available for comparison purposes. The first cohort (n=88) consisted of both males and females and had a high percentage of abnormal samples, while the second cohort (n=624) consisted of only females and was not enriched for expansion mutations. Data from each cohort were completely concordant with the results previously obtained during the course of diagnostic testing. This study further demonstrates the utility of using laboratory-developed triplet repeat-primed FMR1 testing in a clinical setting.
Klein, Britt; Meyer, Denny; Austin, David William; Abbott, Jo-Anne M
2015-01-01
Background Internet-based assessment has the potential to assist with the diagnosis of mental health disorders and overcome the barriers associated with traditional services (eg, cost, stigma, distance). Further to existing online screening programs available, there is an opportunity to deliver more comprehensive and accurate diagnostic tools to supplement the assessment and treatment of mental health disorders. Objective The aim was to evaluate the diagnostic criterion validity and test-retest reliability of the electronic Psychological Assessment System (e-PASS), an online, self-report, multidisorder, clinical assessment and referral system. Methods Participants were 616 adults residing in Australia, recruited online, and representing prospective e-PASS users. Following e-PASS completion, 158 participants underwent a telephone-administered structured clinical interview and 39 participants repeated the e-PASS within 25 days of initial completion. Results With structured clinical interview results serving as the gold standard, diagnostic agreement with the e-PASS varied considerably from fair (eg, generalized anxiety disorder: κ=.37) to strong (eg, panic disorder: κ=.62). Although the e-PASS’ sensitivity also varied (0.43-0.86) the specificity was generally high (0.68-1.00). The e-PASS sensitivity generally improved when reducing the e-PASS threshold to a subclinical result. Test-retest reliability ranged from moderate (eg, specific phobia: κ=.54) to substantial (eg, bulimia nervosa: κ=.87). Conclusions The e-PASS produces reliable diagnostic results and performs generally well in excluding mental disorders, although at the expense of sensitivity. For screening purposes, the e-PASS subclinical result generally appears better than a clinical result as a diagnostic indicator. Further development and evaluation is needed to support the use of online diagnostic assessment programs for mental disorders. Trial Registration Australian and New Zealand Clinical Trials Registry ACTRN121611000704998; http://www.anzctr.org.au/trial_view.aspx?ID=336143 (Archived by WebCite at http://www.webcitation.org/618r3wvOG). PMID:26392066
Alkaline phosphatase as a screening test for osteomalacia.
Chinoy, Muhammad Amin; Javed, Muhammad Imran; Khan, Alamzeb; Sadruddin, Nooruddin
2011-01-01
Vitamin D deficiency remains common in children and adults in Pakistan despite adequate sunlight exposure. Diagnosis in adults is usually delayed and is made following pathological fractures that result in significant morbidity. The objective of this study was to see whether Serum Alkaline Phosphatase levels could be used as a screening test for osteomalacia. The Study was conducted at Fatima Hospital, Baqai Medical University, Gadap, Karachi, between July 2002 and June 2005. Serum calcium levels are commonly used to screen patients suspected of osteomalacia, and raised serum alkaline phosphatase (SALP) is considered a diagnostic finding. We used SALP to screen patients who presented with back or non-specific aches and pain of more than six months duration. Three hundred thirty-four (334) patients were screened of which 116 (35%) had raised SALP. Osteomalacia was diagnosed in 92 (79.3%) of these 116 either by plain radiographs, bone biopsy or isotope bone scan. Fifty-four (53.4%) of the 101 cases had a normal level of serum calcium. Osteomalacia is likely to be missed if only serum calcium is used to screen patients. Serum Alkaline Phosphate should be used as the preferred method for screening these patients.
Screening or Symptoms? How Do We Detect Colorectal Cancer in an Equal Access Health Care System?
Hatch, Quinton M; Kniery, Kevin R; Johnson, Eric K; Flores, Shelly A; Moeil, David L; Thompson, John J; Maykel, Justin A; Steele, Scott R
2016-02-01
Detection of colorectal cancer ideally occurs at an early stage through proper screening. We sought to establish methods by which colorectal cancers are diagnosed within an equal access military health care population and evaluate the correlation between TNM stage at colorectal cancer diagnosis and diagnostic modality (i.e., symptomatic detection vs screen detection). A retrospective chart review of all newly diagnosed colorectal cancer patients from January 2007 to August 2014 was conducted at the authors' equal access military institution. We evaluated TNM stage relative to diagnosis by screen detection (fecal occult blood test, flexible sigmoidoscopy, CT colonography, colonoscopy) or symptomatic evaluation (diagnostic colonoscopy or surgery). Of 197 colorectal cancers diagnosed (59 % male; mean age 62 years), 50 (25 %) had stage I, 47 (24 %) had stage II, 70 (36 %) had stage III, and 30 (15 %) had stage IV disease. Twenty-five percent of colorectal cancers were detected via screen detection (3 % by fecal occult blood testing (FOBT), 0.5 % by screening CT colonography, 17 % by screening colonoscopy, and 5 % by surveillance colonoscopy). One hundred forty-eight (75 %) were diagnosed after onset of signs or symptoms. The preponderance of these was advanced-stage disease (stages III-IV), although >50 % of stage I-II disease also had signs or symptoms at diagnosis. The most common symptoms were rectal bleeding (45 %), abdominal pain (35 %), and change in stool caliber (27 %). The most common overall sign was anemia (60 %). Screening FOBT (odds ratio (OR) 8.7, 95 % confidence interval (CI) 1.0-78.3; P = 0.05) independently predicted early diagnosis with stage I-II disease. Patient gender and ethnicity were not associated with cancer stage at diagnosis. Despite equal access to colorectal cancer screening, diagnosis after development of symptomatic cancer remains more common. Fecal occult blood screen detection is associated with early stage at colorectal cancer diagnosis and is the focus for future initiatives.
Medical training fails to prepare providers to care for patients with chronic hepatitis B infection
Chao, Stephanie D; Wang, Bing-Mei; Chang, Ellen T; Ma, Li; So, Samuel K
2015-01-01
AIM: To investigate physicians’ knowledge including chronic hepatitis B (CHB) diagnosis, screening, and management in various stages of their training. METHODS: A voluntary 20-question survey was administered in Santa Clara County, CA where Asian and Pacific Islanders (API) account for a third of the population. Among the 219 physician participants, there were 63 interns, 60 second-year residents, 26 chief residents and 70 attending physicians. The survey asked questions regarding respondents’ demographics, general hepatitis B virus knowledge questions (i.e., transmission, prevalence, diagnostic testing, prevention, and treatment options), as well as, self-reported practice behavior and confidence in knowledge. RESULTS: Knowledge about screening and managing patients with CHB was poor: only 24% identified the correct tests to screen for CHB, 13% knew the next steps for patients testing positive for CHB, 18% knew the high prevalence rate among API, and 31% knew how to screen for liver cancer. Wald chi-square analysis determined the effect of training level on knowledge; in all cases except for knowledge of liver cancer screening (P = 0.0032), knowledge did not significantly increase with length in residency training or completion of residency. CONCLUSION: Even in a high-risk region, both medical school and residency training have not adequately prepared physicians in the screening and management of CHB. PMID:26078568
Odenbach, Jeffrey; Newton, Amanda; Gokiert, Rebecca; Falconer, Cathy; Courchesne, Craig; Campbell, Sandra; Curtis, Sarah J
2014-03-02
Pediatric injury is highly prevalent and has significant impact both physically and emotionally. The majority of pediatric injuries are treated in emergency departments (EDs), where treatment of physical injuries is the main focus. In addition to physical trauma, children often experience significant psychological trauma, and the development of acute stress disorder (ASD) and post-traumatic stress disorder (PTSD) is common. The consequences of failing to recognize and treat children with ASD and PTSD are significant and extend into adulthood. Currently, screening guidelines to identify children at risk for developing these stress disorders are not evident in the pediatric emergency setting. The goal of this systematic review is to summarize evidence on the psychometric properties, diagnostic accuracy, and clinical utility of screening tools that identify or predict PTSD secondary to physical injury in children. Specific research objectives are to: (1) identify, describe, and critically evaluate instruments available to screen for PTSD in children; (2) review and synthesize the test-performance characteristics of these tools; and (3) describe the clinical utility of these tools with focus on ED suitability. Computerized databases including MEDLINE, EMBASE, CINAHL, ISI Web of Science and PsycINFO will be searched in addition to conference proceedings, textbooks, and contact with experts. Search terms will include MeSH headings (post-traumatic stress or acute stress), (pediatric or children) and diagnosis. All articles will be screened by title/abstract and articles identified as potentially relevant will be retrieved in full text and assessed by two independent reviewers. Quality assessment will be determined using the QUADAS-2 tool. Screening tool characteristics, including type of instrument, number of items, administration time and training administrators level, will be extracted as well as gold standard diagnostic reference properties and any quantitative diagnostic data (specificity, positive and negative likelihood/odds ratios) where appropriate. Identifying screening tools to recognize children at risk of developing stress disorders following trauma is essential in guiding early treatment and minimizing long-term sequelae of childhood stress disorders. This review aims to identify such screening tools in efforts to improve routine stress disorder screening in the pediatric ED setting. PROSPERO registration: CRD42013004893.
Nygren, David; Isaksson, Arvid Lissel
2014-02-04
During the last decade much progress has been made in reducing malaria transmission in Macha, Southern Province, Zambia. Introduction of artemisinin combination therapies as well as mass screenings of asymptomatic carriers is believed to have contributed the most. When an endemic malaria situation is moving towards a non-endemic situation the resident population loses acquired immunity and therefore active case detection and efficient surveillance is crucial to prevent epidemic outbreaks. Our purpose was to evaluate the impact of cell phone surveillance and geographical information systems on malaria control in Macha. Furthermore, it evaluates what screening and treatment of asymptomatic carriers and implementation of rapid diagnostic tests in rural health care has led to. Ten in-depth semi-structured interviews, field observations and data collection were performed at the Macha Research Trust and at surrounding rural health centers. This qualitative method was inspired by rapid assessment procedure. The cell phone surveillance has been easily integrated in health care, and its integration with Geographical Information Systems has provided the ability to follow malaria transmission on a weekly basis. In addition, active case detection of asymptomatic carriers has been fruitful, which is reflected in it soon being applied nationwide. Furthermore, rapid diagnostic tests have provided rural health centers with reliable malaria diagnostics, thereby decreasing excessive malaria treatments and selection for drug resistance. This report reflects the importance of asymptomatic carriers in targeting malaria elimination, as well as development of effective surveillance systems when transmission decreases. Such an approach would be cost-efficient in the long run through positive effects in reduced child mortality and relief in health care.
Gestational diabetes mellitus screening, management and outcomes in the Cook Islands.
Aung, Yin Yin May; Sowter, Martin; Kenealy, Timothy; Herman, Josephine; Ekeroma, Alec
2015-04-17
To describe current practices for screening for gestational diabetes mellitus in the Cook Islands and consider the implications of alternative screening strategies. Eligible women had antenatal care from January 2009 to December 2012. A non-fasting 50 g glucose challenge between 24 and 28 weeks gestation (positive if 1-hour glucose greater than or equal to 7.8 mmol/L) was followed by a 75 g oral glucose tolerance test (gestational diabetes mellitus diagnosed if fasting glucose greater than or equal to 5.2 mmol/L or 2-hour glucose greater than or equal to 8.0 mmol/L; pregnancy impaired glucose tolerance if positive screen and negative diagnostic test). Uptake of the screening programme rose from 49.0% to 99.6% by the end of the study period. 646 women had a glucose challenge; for 186/646 (28.8%) the challenge was positive; 183 had an oral glucose tolerance test; 89/646 (13.8%) had pregnancy impaired glucose tolerance; 94/646 (13.9%) had gestational diabetes mellitus. Median maternal weight gain was 6 kg (gestational diabetes mellitus) and 10 kg (normal glucose tolerance); caesarean section rates were 25% and 11% respectively; baby birthweights were not significantly different. 59 women with gestational diabetes mellitus had a post-natal glucose tolerance test at their 6-week check and 21 (35.6%) had diabetes confirmed. The gestational diabetes mellitus screening programme has a high uptake and current management appears effective in reducing maternal and fetal weight gain. A proposed new screening programme is outlined.
Leblanc, Judith; Rousseau, Alexandra; Hejblum, Gilles; Durand-Zaleski, Isabelle; de Truchis, Pierre; Lert, France; Costagliola, Dominique; Simon, Tabassome; Crémieux, Anne-Claude
2016-02-01
In 2010, to reduce late HIV diagnosis, the French national health agency endorsed non-targeted HIV screening in health care settings. Despite these recommendations, non-targeted screening has not been implemented and only physician-directed diagnostic testing is currently performed. A survey conducted in 2010 in 29 French Emergency Departments (EDs) showed that non-targeted nurse-driven screening was feasible though only a few new HIV diagnoses were identified, predominantly among high-risk groups. A strategy targeting high-risk groups combined with current practice could be shown to be feasible, more efficient and cost-effective than current practice alone. DICI-VIH (acronym for nurse-driven targeted HIV screening) is a multicentre, cluster-randomized, two-period crossover trial. The primary objective is to compare the effectiveness of 2 strategies for diagnosing HIV among adult patients visiting EDs: nurse-driven targeted HIV screening combined with current practice (physician-directed diagnostic testing) versus current practice alone. Main secondary objectives are to compare access to specialist consultation and how early HIV diagnosis occurs in the course of the disease between the 2 groups, and to evaluate the implementation, acceptability and cost-effectiveness of nurse-driven targeted screening. The 2 strategies take place during 2 randomly assigned periods in 8 EDs of metropolitan Paris, where 42 % of France's new HIV patients are diagnosed every year. All patients aged 18 to 64, not presenting secondary to HIV exposure are included. During the intervention period, patients are invited to fill a 7-item questionnaire (country of birth, sexual partners and injection drug use) in order to select individuals who are offered a rapid test. If the rapid test is reactive, a follow-up visit with an infectious disease specialist is scheduled within 72 h. Assuming an 80 % statistical power and a 5 % type 1 error, with 1.04 and 3.38 new diagnoses per 10,000 patients in the control and targeted groups respectively, a sample size of 140,000 patients was estimated corresponding to 8,750 patients per ED and per period. Inclusions started in June 2014. Results are expected by mid-2016. The DICI-VIH study is the first large randomized controlled trial designed to assess nurse-driven targeted HIV screening. This study can provide valuable information on HIV screening in health care settings. ClinicalTrials.gov: NCT02127424 (29 April 2014).
Bensink, Mark E.; Ramsey, Scott D.; Battaglia, Tracy; Fiscella, Kevin; Hurd, Thelma C.; McKoy, June M.; Patierno, Steven R.; Raich, Peter C.; Seiber, Eric E.; Mears, Victoria Warren; Whitley, Elizabeth; Paskett, Electra D.; Mandelblatt, Jeanne S.
2013-01-01
Background Navigators can facilitate timely access to cancer services but there are little data on their economic impact. Methods We conduct a cost-consequence analysis of navigation vs. usual care among 10,521 individuals with abnormal breast, cervix, colorectal or prostate cancer screening results who enrolled in the Patient Navigation Research Program study from January 1 2006 to March 31 2010. Navigation costs included diagnostic evaluation, patient and staff time, materials, and overhead. Consequences or outcomes were time to diagnostic resolution and probability of resolution. Differences in costs and outcomes were evaluated using multi-level, mixed-effects regression adjusting for age, race/ethnicity, language, marital status, insurance, cancer, and site clustering. Results Most individuals were minority (70.7%) and un- or publically-insured (72.7%). Diagnostic resolution was higher for navigation vs. usual care at 180 (56.2% vs. 53.8%, p=0.008) and 270 days: 70.0% vs. 68.2%, p<0.001). While there were no differences in average days to resolution (110 vs. 109 days, p=.63), the probability of ever having diagnostic resolution was higher for navigation vs. usual care (84.5% vs. 79.6%, p <0.001). The added cost of navigation vs. usual care was $275 per patient (95% CI $260 – $290, p <0.001). There was no significant difference in stage distribution among the 12.4% of navigated vs. 11% of usual care patients diagnosed with cancer. Conclusions Navigation adds costs and modestly increases the probability of diagnostic resolution among patients with abnormal screening tests. Navigation is only likely to be cost-effective if improved resolution translates into earlier cancer stage at diagnosis. PMID:24166217
White, Helen E; Hall, Victoria J; Cross, Nicholas C P
2007-11-01
Angelman syndrome (AS) and Prader-Willi syndrome (PWS) are 2 distinct neurodevelopmental disorders caused primarily by deficiency of specific parental contributions at an imprinted domain within the chromosomal region 15q11.2-13. Lack of paternal contribution results in PWS either by paternal deletion (approximately 70%) or maternal uniparental disomy (UPD) (approximately 25%). Most cases of AS result from the lack of a maternal contribution from this same region, by maternal deletion (70%) or paternal UPD (approximately 5%). Analysis of allelic methylation differences at the small nuclear ribonucleoprotein polypeptide N (SNRPN) locus differentiates the maternally and paternally inherited chromosome 15 and can be used as a diagnostic test for AS and PWS. Methylation-sensitive high-resolution melting-curve analysis (MS-HRM) using the DNA binding dye EvaGreen was used to analyze methylation differences at the SNRPN locus in anonymized DNA samples from individuals with PWS (n = 39) or AS (n = 31) and from healthy control individuals (n = 95). Results from the MS-HRM assay were compared to those obtained by use of a methylation-specific PCR (MSP) protocol that is used commonly in diagnostic practice. With the MS-HRM assay 97.6% of samples were unambiguously assigned to the 3 diagnostic categories (AS, PWS, normal) by use of automated calling with an 80% confidence percentage threshold, and the failure rate was 0.6%. One PWS sample showed a discordant result for the MS-HRM assay compared to MSP data. MS-HRM is a simple, rapid, and robust method for screening methylation differences at the SNRPN locus and could be used as a diagnostic screen for PWS and AS.
Focused use of drug screening in overdose patients increases impact on management.
Erdmann, Andreas; Werner, Dominique; Hugli, Olivier; Yersin, Bertrand
2015-01-01
Drug poisoning is a common cause for attendance in the emergency department. Several toxicology centres suggest performing urinary drug screens, even though they rarely influence patient management. Measuring the impact on patient management, in a University Emergency Department with approximately 40 000 admissions annually, of a rapid urinary drug screening test using specifically focused indications. Drug screening was restricted to patients having a first psychotic episode or cases demonstrating respiratory failure, coma, seizures, a sympathomimetic toxidrome, severe opiate overdose necessitating naloxone, hypotension, ventricular arrhythmia, acquired long QT or QRS >100 ms, and high-degree heart block. Retrospective analysis of Triage® TOX drug screen tests performed between September 2009 and November 2011, and between January 2013 and March 2014. A total of 262 patients were included, mean age 35 ± 14.6 (standard deviation) years, 63% men; 29% poisoning with alcohol, and 2.3% deaths. Indications for testing were as follows: 34% were first psychotic episodes; 20% had acute respiratory failure; 16% coma; 8% seizures; 8% sympathomimetic toxidromes; 7% severe opioid toxidromes; 4% hypotension; 3% ventricular arrhythmias or acquired long QT intervals on electrocardiogram. A total of 78% of the tests were positive (median two substances, maximum five). The test resulted in drug-specific therapy in 6.1%, drug specific diagnostic tests in 13.3 %, prolonged monitoring in 10.7% of methadone-positive tests, and psychiatric admission in 4.2%. Overall, 34.3% tests influenced patient management. In contrast to previous studies showing modest effects of toxicological testing, restricted use of rapid urinary drug testing increases the impact on management of suspected overdose patients in the ED.
Clinical Utility of Fungal Screening Assays in Adults with Severe Burns
2013-01-01
available test, FungitellTM Glucan Assay for (1,3) b D glucan (BG) in serum (Associates of Cape Cod Inc., East Falmouth, MA), is a qualitative...considered a positive test in the United States and was used as a positive value in this study. A positive test is reported with a b D glucan concentration... Glucan as a diagnostic adjunct for invasive fungal infections: validation, cutoff development, and performance in patients with acute myelogenous
Evaluation of a Rapid Diagnostic Test for Yaws Infection in a Community Surveillance Setting
Marks, Michael; Goncalves, Adriana; Vahi, Ventis; Sokana, Oliver; Puiahi, Elliot; Zhang, Zaixing; Dalipanda, Tenneth; Bottomley, Christian; Mabey, David; Solomon, Anthony W.
2014-01-01
Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT) for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR) and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA) setting. PMID:25211018
Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.
Marks, Michael; Goncalves, Adriana; Vahi, Ventis; Sokana, Oliver; Puiahi, Elliot; Zhang, Zaixing; Dalipanda, Tenneth; Bottomley, Christian; Mabey, David; Solomon, Anthony W
2014-09-01
Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT) for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR) and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA) setting.
Henschke, Nicholas; Keuerleber, Julia; Ferreira, Manuela; Maher, Christopher G; Verhagen, Arianne P
2014-04-01
To provide an overview of reporting and methodological quality in diagnostic test accuracy (DTA) studies in the musculoskeletal field and evaluate the use of the QUality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist. A literature review identified all systematic reviews that evaluated the accuracy of clinical tests to diagnose musculoskeletal conditions and used the QUADAS checklist. Two authors screened all identified reviews and extracted data on the target condition, index tests, reference standard, included studies, and QUADAS items. A descriptive analysis of the QUADAS checklist was performed, along with Rasch analysis to examine the construct validity and internal reliability. A total of 19 systematic reviews were included, which provided data on individual items of the QUADAS checklist for 392 DTA studies. In the musculoskeletal field, uninterpretable or intermediate test results are commonly not reported, with 175 (45%) studies scoring "no" to this item. The proportion of studies fulfilling certain items varied from 22% (item 11) to 91% (item 3). The interrater reliability of the QUADAS checklist was good and Rasch analysis showed excellent construct validity and internal consistency. This overview identified areas where the reporting and performance of diagnostic studies within the musculoskeletal field can be improved. Copyright © 2014 Elsevier Inc. All rights reserved.
Li, Pei-Chun; Chen, Wei-I; Huang, Chih-Ming; Liu, Ching-Ju; Chang, Hsiu-wen; Lin, Hung-Ching
2016-01-01
Objectives To determine whether newborn hearing screening in a well-baby nursery (WBN) and neonatal intensive care unit (NICU) nursery: 1) meet three targeted, screening, referral, and diagnostic follow-up rates; 2) compare the average age of diagnosis for infants admitted to the WIN and NICU; and 3) determine prevalence of hearing loss in neonatal population; and 4) try to find a practical newborn hearing screening time algorithm to reduce refer rate in NICU Materials and Methods It examined 15,624 newborns in the WBN (13,676) and NICU (1948) screened for congenital HL using AABR. The variables analyzed in it were the screening rate, referral rate, follow-up rate, diagnostic rate and diagnostic age, prevalence rate, degrees of congenital bilateral HL. The study was approved by the hospital’s institutional review board (13MMHISO23). Results The screening rates were 99.8% and 99.6% in the WBN and NICU groups, respectively, without significant difference. The referral rates were 0.7% and 2.8% in the WBN and NICU groups, with significant difference. Furthermore, the diagnostic follow-up rates were 76.7% and 89.1% in the WBN and NICU groups, without significant difference. The average initial diagnostic ages were 1.9 months and 3.8 months in the WBN and NICU groups, with significant difference. The prevalence of congenital bilateral hearing loss were 0.27% and 1.6% in the WBN and NICU groups, with significant difference. Conclusion The screening, referral and follow-up rate in the WBN and NICU groups were equivalent to the quality indicators. For NICU group, screening and diagnostic follow up were performed later than those in WBN group; however the lower referral rate in our NICU group was successfully achieved in this study and can be applied clinically. The prevalence of congenital bilateral hearing loss was higher in the NICU group than in the WBN group. PMID:27023324
Li, Pei-Chun; Chen, Wei-I; Huang, Chih-Ming; Liu, Ching-Ju; Chang, Hsiu-wen; Lin, Hung-Ching
2016-01-01
To determine whether newborn hearing screening in a well-baby nursery (WBN) and neonatal intensive care unit (NICU) nursery: 1) meet three targeted, screening, referral, and diagnostic follow-up rates; 2) compare the average age of diagnosis for infants admitted to the WIN and NICU; and 3) determine prevalence of hearing loss in neonatal population; and 4) try to find a practical newborn hearing screening time algorithm to reduce refer rate in NICU. It examined 15,624 newborns in the WBN (13,676) and NICU (1948) screened for congenital HL using AABR. The variables analyzed in it were the screening rate, referral rate, follow-up rate, diagnostic rate and diagnostic age, prevalence rate, degrees of congenital bilateral HL. The study was approved by the hospital's institutional review board (13MMHISO23). The screening rates were 99.8% and 99.6% in the WBN and NICU groups, respectively, without significant difference. The referral rates were 0.7% and 2.8% in the WBN and NICU groups, with significant difference. Furthermore, the diagnostic follow-up rates were 76.7% and 89.1% in the WBN and NICU groups, without significant difference. The average initial diagnostic ages were 1.9 months and 3.8 months in the WBN and NICU groups, with significant difference. The prevalence of congenital bilateral hearing loss were 0.27% and 1.6% in the WBN and NICU groups, with significant difference. The screening, referral and follow-up rate in the WBN and NICU groups were equivalent to the quality indicators. For NICU group, screening and diagnostic follow up were performed later than those in WBN group; however the lower referral rate in our NICU group was successfully achieved in this study and can be applied clinically. The prevalence of congenital bilateral hearing loss was higher in the NICU group than in the WBN group.
Ho, Sirikit; Lukacs, Zoltan; Hoffmann, Georg F; Lindner, Martin; Wetter, Thomas
2007-07-01
In newborn screening with tandem mass spectrometry, multiple intermediary metabolites are quantified in a single analytical run for the diagnosis of fatty-acid oxidation disorders, organic acidurias, and aminoacidurias. Published diagnostic criteria for these disorders normally incorporate a primary metabolic marker combined with secondary markers, often analyte ratios, for which the markers have been chosen to reflect metabolic pathway deviations. We applied a procedure to extract new markers and diagnostic criteria for newborn screening to the data of newborns with confirmed medium-chain acyl-CoA dehydrogenase deficiency (MCADD) and a control group from the newborn screening program, Heidelberg, Germany. We validated the results with external data of the screening center in Hamburg, Germany. We extracted new markers by performing a systematic search for analyte combinations (features) with high discriminatory performance for MCADD. To select feature thresholds, we applied automated procedures to separate controls and cases on the basis of the feature values. Finally, we built classifiers from these new markers to serve as diagnostic criteria in screening for MCADD. On the basis of chi(2) scores, we identified approximately 800 of >628,000 new analyte combinations with superior discriminatory performance compared with the best published combinations. Classifiers built with the new features achieved diagnostic sensitivities and specificities approaching 100%. Feature construction methods provide ways to disclose information hidden in the set of measured analytes. Other diagnostic tasks based on high-dimensional metabolic data might also profit from this approach.
Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy
Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum
2017-01-01
Background: The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. Objectives: The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Design: Retrospective study. Methods: Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. Results: The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% (P < 0.0001); specificity, 98.53% and 86.76% (P = 0.0026); accuracy, 77.04% and 85.93% (P = 0.0423), respectively. Conclusions: The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test. PMID:28824298
Prince, Mark; Lester, Lynn; Chiniwala, Rupal; Berger, Barry
2017-01-01
AIM To determine the uptake of noninvasive multitarget stool DNA (mt-sDNA) in a cohort of colorectal cancer (CRC) screening non-compliant average-risk Medicare patients. METHODS This cross sectional primary care office-based study examined mt-sDNA uptake in routine clinical practice among 393 colorectal cancer screening non-compliant Medicare patients ages 50-85 ordered by 77 physicians in a multispecialty group practice (USMD Physician Services, Dallas, TX) from October, 2014-September, 2015. Investigators performed a Health Insurance Portability and Accountability Act compliant retrospective review of electronic health records to identify mt-sDNA use in patients who were either > 10 years since last colonoscopy and/or > 1 year since last fecal occult blood test. Test positive patients were advised to get diagnostic colonoscopy and thereafter patients were characterized by the most clinically significant lesion documented on histopathology of biopsies or excisional tissue. Descriptive statistics were employed. Key outcome measures included mt-sDNA compliance and diagnostic colonoscopy compliance on positive cases. RESULTS Over 12 mo, 77 providers ordered 393 mt-sDNA studies with 347 completed (88.3% compliance). Patient mean age was 69.8 (50-85) and patients were 64% female. Mt-sDNA was negative in 85.3% (296/347) and positive in 14.7% (51/347). Follow-up colonoscopy was performed in 49 positive patients (96.1% colonoscopy compliance) with two patients lost to follow up. Index findings included: colon cancer (4/49, 8.2%), advanced adenomas (21/49, 42.9%), non-advanced adenomas (15/49, 30.6%), and negative results (9/49, 18.4%). The positive predictive value for advanced colorectal lesions was 51.0% and for any colorectal neoplasia was 81.6%. The mean age of patients with colorectal cancer was 70.3 and all CRC's were localized Stage I (2) and Stage II (2), three were located in the proximal colon and one was located in the distal colon. CONCLUSION Mt-sDNA provided medical benefit to screening noncompliant Medicare population. High compliance with mt-sDNA and subsequent follow-up diagnostic colonoscopy identified patients with clinically critical advanced colorectal neoplasia. PMID:28210082
Prince, Mark; Lester, Lynn; Chiniwala, Rupal; Berger, Barry
2017-01-21
To determine the uptake of noninvasive multitarget stool DNA (mt-sDNA) in a cohort of colorectal cancer (CRC) screening non-compliant average-risk Medicare patients. This cross sectional primary care office-based study examined mt-sDNA uptake in routine clinical practice among 393 colorectal cancer screening non-compliant Medicare patients ages 50-85 ordered by 77 physicians in a multispecialty group practice (USMD Physician Services, Dallas, TX) from October, 2014-September, 2015. Investigators performed a Health Insurance Portability and Accountability Act compliant retrospective review of electronic health records to identify mt-sDNA use in patients who were either > 10 years since last colonoscopy and/or > 1 year since last fecal occult blood test. Test positive patients were advised to get diagnostic colonoscopy and thereafter patients were characterized by the most clinically significant lesion documented on histopathology of biopsies or excisional tissue. Descriptive statistics were employed. Key outcome measures included mt-sDNA compliance and diagnostic colonoscopy compliance on positive cases. Over 12 mo, 77 providers ordered 393 mt-sDNA studies with 347 completed (88.3% compliance). Patient mean age was 69.8 (50-85) and patients were 64% female. Mt-sDNA was negative in 85.3% (296/347) and positive in 14.7% (51/347). Follow-up colonoscopy was performed in 49 positive patients (96.1% colonoscopy compliance) with two patients lost to follow up. Index findings included: colon cancer (4/49, 8.2%), advanced adenomas (21/49, 42.9%), non-advanced adenomas (15/49, 30.6%), and negative results (9/49, 18.4%). The positive predictive value for advanced colorectal lesions was 51.0% and for any colorectal neoplasia was 81.6%. The mean age of patients with colorectal cancer was 70.3 and all CRC's were localized Stage I (2) and Stage II (2), three were located in the proximal colon and one was located in the distal colon. Mt-sDNA provided medical benefit to screening noncompliant Medicare population. High compliance with mt-sDNA and subsequent follow-up diagnostic colonoscopy identified patients with clinically critical advanced colorectal neoplasia.
Use of a pLDH-based dipstick in the diagnostic and therapeutic follow-up of malaria patients in Mali
2011-01-01
Background Malaria is a major public health problem in Mali and diagnosis is typically based on microscopy. Microscopy requires a well trained technician, a reliable power source, a functioning microscope and adequate supplies. The scarcity of resources of community health centres (CHC) does not allow for such a significant investment in only one aspect of malaria control. In this context, Rapid Diagnostic Tests (RDTs) may improve case management particularly in remote areas. Methods This multicentre study included 725 patients simultaneously screened with OptiMal-IT test and thick smears for malaria parasite detection. While evaluating the therapeutic efficacy of choroquine in 2 study sites, we compared the diagnostic values of thick smear microscopy to OptiMal-IT test applying the WHO 14 days follow-up scheme using samples collected from 344 patients. Results The sensitivity and the specificity of OptiMal-IT compared to thick smear was 97.2% and 95.4%, whereas the positive and negative predictive values were 96.7 and 96.1%, respectively. The percent agreement between the two diagnostic tests was 0.93. The two tests were comparable in detecting malaria at day 0, day 3 and day 14. The only difference was observed at day 7 due to high gametocytemia. Subjectively, health care providers found OptiMal-IT easier to use and store under field conditions. Conclusion OptiMal-IT test revealed similar results when compared to microscopy which is considered the gold standard for malaria diagnostics. The test was found to have a short processing time and was easier to use. These advantages may improve malaria case management by providing a diagnostic and drug efficacy follow-up tool to peripheral health centres with limited resources. PMID:22114867
McDonald, Yolanda J; Goldberg, Daniel W; Scarinci, Isabel C; Castle, Philip E; Cuzick, Jack; Robertson, Michael; Wheeler, Cosette M
2017-09-01
Multiple intrapersonal and structural barriers, including geography, may prevent women from engaging in cervical cancer preventive care such as screening, diagnostic colposcopy, and excisional precancer treatment procedures. Geographic accessibility, stratified by rural and nonrural areas, to necessary services across the cervical cancer continuum of preventive care is largely unknown. Health care facility data for New Mexico (2010-2012) was provided by the New Mexico Human Papillomavirus Pap Registry (NMHPVPR), the first population-based statewide cervical cancer screening registry in the United States. Travel distance and time between the population-weighted census tract centroid to the nearest facility providing screening, diagnostic, and excisional treatment services were examined using proximity analysis by rural and nonrural census tracts. Mann-Whitney test (P < .05) was used to determine if differences were significant and Cohen's r to measure effect. Across all cervical cancer preventive health care services and years, women who resided in rural areas had a significantly greater geographic accessibility burden when compared to nonrural areas (4.4 km vs 2.5 km and 4.9 minutes vs 3.0 minutes for screening; 9.9 km vs 4.2 km and 10.4 minutes vs 4.9 minutes for colposcopy; and 14.8 km vs 6.6 km and 14.4 minutes vs 7.4 minutes for precancer treatment services, all P < .001). Improvements in cervical cancer prevention should address the potential benefits of providing the full spectrum of screening, diagnostic and precancer treatment services within individual facilities. Accessibility, assessments distinguishing rural and nonrural areas are essential when monitoring and recommending changes to service infrastructures (eg, mobile versus brick and mortar). © 2016 National Rural Health Association.
Uysal-Cantürk, P; Hanağası, H A; Bilgiç, B; Gürvit, H; Emre, M
2018-01-01
Cognitive impairment is one of the most disabling non-motor symptoms of Parkinson's disease. Mild cognitive impairment constitutes a major risk for the development of Parkinson's disease dementia in the course of the disease. A Movement Disorder Society Task Force proposed diagnostic criteria for mild cognitive impairment in Parkinson's disease (PD-MCI), comprising two operational levels: Level I and Level II. The objective of our study was to test the accuracy of Level I versus Level II diagnostic criteria. Eighty-six consecutive patients with Parkinson's disease were screened and 68 patients without dementia or depression were included in the study. We used the Montreal Cognitive Assessment, Mini-Mental State Examination and Addenbrooke's Cognitive Evaluation-R screening tools for Level I and an extensive neuropsychological battery for Level II assessment. We first diagnosed PD-MCI on the basis of Level II assessment and then calculated sensitivity, specificity and area under the receiver-operator characteristics curve, comparing the performance of the three screening batteries. None of the three screening batteries proposed for Level I assessment provided satisfactory combined sensitivity and specificity for detecting PD-MCI, and their performance was similar. Using the Level II criteria, 29 patients (43%) were diagnosed as having PD-MCI. Lowest cut-off levels that provided at least 80% sensitivity were 24 for the Montreal Cognitive Assessment, 29 for the Mini-Mental State Examination and 87 for the Addenbrooke's Cognitive Evaluation-R. However, specificity levels were below 80% at these cut-off levels. We conclude that Level I assessment alone using screening batteries is not sufficiently sensitive/specific to detect PD-MCI. © 2017 EAN.
McDonald, Yolanda J.; Goldberg, Daniel W.; Scarinci, Isabel C.; Castle, Philip E.; Cuzick, Jack; Robertson, Michael; Wheeler, Cosette M.
2018-01-01
Purpose Multiple intrapersonal and structural barriers, including geography, may prevent women from engaging in cervical cancer preventive care such as screening, diagnostic colposcopy, and excisional precancer treatment procedures. Geographic accessibility, stratified by rural and nonrural areas, to necessary services across the cervical cancer continuum of preventive care is largely unknown. Methods Health care facility data for New Mexico (2010-2012) was provided by the New Mexico Human Papillomavirus Pap Registry (NMHPVPR), the first population-based statewide cervical cancer screening registry in the United States. Travel distance and time between the population-weighted census tract centroid to the nearest facility providing screening, diagnostic, and excisional treatment services were examined using proximity analysis by rural and nonrural census tracts. Mann-Whitney test (P < .05) was used to determine if differences were significant and Cohen's r to measure effect. Findings Across all cervical cancer preventive health care services and years, women who resided in rural areas had a significantly greater geographic accessibility burden when compared to nonrural areas (4.4 km vs 2.5 km and 4.9 minutes vs 3.0 minutes for screening; 9.9 km vs 4.2 km and 10.4 minutes vs 4.9 minutes for colposcopy; and 14.8 km vs 6.6 km and 14.4 minutes vs 7.4 minutes for precancer treatment services, all P < .001). Conclusion Improvements in cervical cancer prevention should address the potential benefits of providing the full spectrum of screening, diagnostic and precancer treatment services within individual facilities. Accessibility, assessments distinguishing rural and nonrural areas are essential when monitoring and recommending changes to service infrastructures (eg, mobile versus brick and mortar). PMID:27557124
Miguez, Melissa; Weber, Béatrice; Debbané, Martin; Balanzin, Dario; Gex-Fabry, Marianne; Raiola, Fulvia; Barbe, Rémy P; Vital Bennour, Marylène; Ansermet, François; Eliez, Stephan; Aubry, Jean-Michel
2013-08-01
Screening instruments for bipolar disorders (BDs) in children and adolescents have been developed recently. The present study examined performances of the French versions of the mood disorder questionnaire-adolescent version (MDQ-A) and child bipolar questionnaire (CBQ) in a sample of in- and outpatients. Seventy-six adolescents (age 13-18) and parents first completed the MDQ-A (adolescent and parent versions) and CBQ screening instruments. About 3 weeks later, they had a diagnostic interview with the Kiddie-schedule for affective disorders and schizophrenia-present and lifetime (K-SADS-PL), and the adolescent MDQ-A self-report was completed a second time. Eight of 76 patients (10.5%) met K-SADS-PL diagnostic criteria for BD. Test-retest reliability of the adolescent MDQ-A self-report was moderate (kappa = 0.66), whereas agreement between adolescent and parent reports was poor (kappa = 0.07). Sensitivity and specificity of the MDQ-A with respect to K-SADS-PL were 75.0% and 57.4% for the adolescent version, and 87.5% and 63.2% for the parent version. Corresponding figures were 50.0% and 73.5% for the CBQ. All three screening instruments had low positive predictive values (17.1% for the MDQ-A adolescent version; 21.9% for the MDQ-A parent version; 18.2% for the CBQ), whereas negative predictive values were higher than 90%. The present study points to modest performances of the MDQ-A and CBQ to detect BDs in adolescents, with diagnostic criteria for BD being unmet for a majority of patients who screened positive. © 2012 Wiley Publishing Asia Pty Ltd.
Blozik, Eva; Scherer, Martin; Lacruz, Maria E; Ladwig, Karl-Heinz
2013-12-23
Screening for depressive disorders in the general adult population is recommended, however, it is unclear which instruments combine user friendliness and diagnostic utility. We evaluated the test performance of a yes/no single item screener for depressive disorders ("Have you felt depressed or sad much of the time in the past year?") in comparison to the depressive disorder module of the Patient Health Questionnaire (PHQ-9). Data from 3184 participants of the population-based KORA F3 survey in Augsburg/ Germany were used to analyse sensitivity, specificity, ROC area, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), and negative predictive value (NPV) of the single item screener in comparison with "depressive mood" and "major depressive disorder" defined according to PHQ-9 (both interviewer-administered versions). In comparison to PHQ-9 "depressive mood", sensitivity was low (46%) with an excellent specificity (94%), (PPV 76%; NPV 82%; LR + 8.04; LR- .572, ROC area .702). When using the more conservative definition for "major depressive disorder", sensitivity increased to 83% with a specificity of 88%. The PPV under the conservative definition was low (32%), but NPV was 99% (LR + 6.65; LR- .196; ROC area .852). Results varied across age groups and between males and females. The single item screener is able to moderately decrease post-test probability of major depressive disorders and to identify populations that should undergo additional, more detailed evaluation for depression. It may have limited utility in combination with additional screening tests or for selection of at-risk populations, but cannot be recommended for routine use as a screening tool in clinical practice.
2012-01-01
Introduction Pre-emptive isolation of suspected methicillin-resistant Staphylococcus aureus (MRSA) carriers is a cornerstone of successful MRSA control policies. Implementation of such strategies is hampered when using conventional cultures with diagnostic delays of three to five days, as many non-carriers remain unnecessarily isolated. Rapid diagnostic testing (RDT) reduces the amount of unnecessary isolation days, but costs and benefits have not been accurately determined in intensive care units (ICUs). Methods Embedded in a multi-center hospital-wide study in 12 Dutch hospitals we quantified cost per isolation day avoided using RDT for MRSA, added to conventional cultures, in ICUs. BD GeneOhm™ MRSA PCR (IDI) and Xpert MRSA (GeneXpert) were subsequently used during 17 and 14 months, and their test characteristics were calculated with conventional culture results as reference. We calculated the number of pre-emptive isolation days avoided and incremental costs of adding RDT. Results A total of 163 patients at risk for MRSA carriage were screened and MRSA prevalence was 3.1% (n = 5). Duration of isolation was 27.6 and 21.4 hours with IDI and GeneXpert, respectively, and would have been 96.0 hours when based on conventional cultures. The negative predictive value was 100% for both tests. Numbers of isolation days were reduced by 44.3% with PCR-based screening at the additional costs of €327.84 (IDI) and €252.14 (GeneXpert) per patient screened. Costs per isolation day avoided were €136.04 (IDI) and €121.76 (GeneXpert). Conclusions In a low endemic setting for MRSA, RDT safely reduced the number of unnecessary isolation days on ICUs by 44%, at the costs of €121.76 to €136.04 per isolation day avoided. PMID:22314204
2013-01-01
Background Screening for depressive disorders in the general adult population is recommended, however, it is unclear which instruments combine user friendliness and diagnostic utility. We evaluated the test performance of a yes/no single item screener for depressive disorders (“Have you felt depressed or sad much of the time in the past year?”) in comparison to the depressive disorder module of the Patient Health Questionnaire (PHQ-9). Methods Data from 3184 participants of the population-based KORA F3 survey in Augsburg/ Germany were used to analyse sensitivity, specificity, ROC area, positive likelihood ratio (LR+), negative likelihood ratio (LR-), positive predictive value (PPV), and negative predictive value (NPV) of the single item screener in comparison with “depressive mood” and “major depressive disorder” defined according to PHQ-9 (both interviewer-administered versions). Results In comparison to PHQ-9 “depressive mood”, sensitivity was low (46%) with an excellent specificity (94%), (PPV 76%; NPV 82%; LR + 8.04; LR- .572, ROC area .702). When using the more conservative definition for “major depressive disorder”, sensitivity increased to 83% with a specificity of 88%. The PPV under the conservative definition was low (32%), but NPV was 99% (LR + 6.65; LR- .196; ROC area .852). Results varied across age groups and between males and females. Conclusions The single item screener is able to moderately decrease post-test probability of major depressive disorders and to identify populations that should undergo additional, more detailed evaluation for depression. It may have limited utility in combination with additional screening tests or for selection of at-risk populations, but cannot be recommended for routine use as a screening tool in clinical practice. PMID:24359193
Zhang, Michael Y.; Keel, Siobán B.; Walsh, Tom; Lee, Ming K.; Gulsuner, Suleyman; Watts, Amanda C.; Pritchard, Colin C.; Salipante, Stephen J.; Jeng, Michael R.; Hofmann, Inga; Williams, David A.; Fleming, Mark D.; Abkowitz, Janis L.; King, Mary-Claire; Shimamura, Akiko
2015-01-01
Accurate and timely diagnosis of inherited bone marrow failure and inherited myelodysplastic syndromes is essential to guide clinical management. Distinguishing inherited from acquired bone marrow failure/myelodysplastic syndrome poses a significant clinical challenge. At present, diagnostic genetic testing for inherited bone marrow failure/myelodysplastic syndrome is performed gene-by-gene, guided by clinical and laboratory evaluation. We hypothesized that standard clinically-directed genetic testing misses patients with cryptic or atypical presentations of inherited bone marrow failure/myelodysplastic syndrome. In order to screen simultaneously for mutations of all classes in bone marrow failure/myelodysplastic syndrome genes, we developed and validated a panel of 85 genes for targeted capture and multiplexed massively parallel sequencing. In patients with clinical diagnoses of Fanconi anemia, genomic analysis resolved subtype assignment, including those of patients with inconclusive complementation test results. Eight out of 71 patients with idiopathic bone marrow failure or myelodysplastic syndrome were found to harbor damaging germline mutations in GATA2, RUNX1, DKC1, or LIG4. All 8 of these patients lacked classical clinical stigmata or laboratory findings of these syndromes and only 4 had a family history suggestive of inherited disease. These results reflect the extensive genetic heterogeneity and phenotypic complexity of bone marrow failure/myelodysplastic syndrome phenotypes. This study supports the integration of broad unbiased genetic screening into the diagnostic workup of children and young adults with bone marrow failure and myelodysplastic syndromes. PMID:25239263
Gravitt, Patti E.; Belinson, Jerome L.; Salmeron, Jorge; Shah, Keerti V.
2012-01-01
Even in the era of highly effective HPV prophylactic vaccines, substantial reduction in worldwide cervical cancer mortality will only be realized if effective early detection and treatment of the millions of women already infection and the millions who may not receive vaccination in the next decade can be broadly implemented through sustainable cervical cancer screening programs. Effective programs must meet three targets: 1) at least 70% of the targeted population should be screened at least once in a lifetime, 2) screening assays and diagnostic tests must be reproducible and sufficiently sensitive and specific for the detection of high-grade precursor lesions (i.e., CIN2+), and 3) effective treatment must be provided. We review the evidence that HPV DNA screening from swabs collected by the women in their home or village is sufficiently sound for consideration as a primary screening strategy in the developing world, with sensitivity and specificity for detection of CIN2+ as good or better than Pap smear cytology and VIA. A key feature of a self-collected HPV testing strategy (SC-HPV) is the move of the primary screening activities from the clinic to the community. Efforts to increase the affordability and availability of HPV DNA tests, community education and awareness, development of strong partnerships between community advocacy groups, health care centers and regional or local laboratories, and resource appropriate strategies to identify and treat screen-positive women should now be prioritized to ensure successful public health translation of the technologic advancements in cervical cancer prevention. PMID:21384341
Rojas, Jorge A; Bernal, Jaime E; García, Mary A; Zarante, Ignacio; Ramírez, Natalia; Bernal, Constanza; Gelvez, Nancy; Tamayo, Marta L
2014-10-01
The aim of this study was to investigate the characteristics and performance of transient evoked oto-acoustic emission (TEOAE) hearing screening in newborns in Colombia, and analyze all possible variables and factors affecting the results. An observational, descriptive and retrospective study with bivariate analysis was performed. The study population consisted of 56,822 newborns evaluated at the private institution, PREGEN. TEOAE testing was carried out as a pediatric hearing screening test from December 2003 to March 2012. The database from PREGEN was revised, and the protocol for evaluation included the same screening test performed twice. Demographic characteristics were recorded and the newborn's background was evaluated. Basic statistics of the qualitative and quantitative variables, and statistical analysis were obtained using the chi-square test. Of the 56,822 records examined, 0.28% were classed as abnormal, which corresponded to a prevalence of 1 in 350. In the screened newborns, 0.08% had a major abnormality or other clinical condition diagnosed, and 0.29% reported a family history of hearing loss. A prevalence of 6.7 in 10,000 was obtained for microtia, which is similar to the 6.4 in 10,000 previously reported in Colombia (database of the Latin-American Collaborative Study of Congenital Malformations - ECLAMC). Statistical analysis demonstrated an association between presenting with a major anomaly and a higher frequency of abnormal results on both TEOAE tests. Newborns in Colombia do not currently undergo screening for the early detection of hearing impairment. The results from this study suggest TEOAE screening tests, when performed twice, are able to detect hearing abnormalities in newborns. This highlights the need to improve the long-term evaluation and monitoring of patients in Colombia through diagnostic tests, and to provide tests that are both sensitive and specific. Furthermore, the use of TEOAE screening is justified by the favorable cost: benefit ratio demonstrated in many countries worldwide. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Beltrame, Anna; Guerriero, Massimo; Angheben, Andrea; Gobbi, Federico; Requena-Mendez, Ana; Zammarchi, Lorenzo; Formenti, Fabio; Perandin, Francesca; Bisoffi, Zeno
2017-01-01
Background Schistosomiasis is a neglected infection affecting millions of people, mostly living in sub-Saharan Africa. Morbidity and mortality due to chronic infection are relevant, although schistosomiasis is often clinically silent. Different diagnostic tests have been implemented in order to improve screening and diagnosis, that traditionally rely on parasitological tests with low sensitivity. Aim of this study was to evaluate the accuracy of different tests for the screening of schistosomiasis in African migrants, in a non endemic setting. Methodology/Principal findings A retrospective study was conducted on 373 patients screened at the Centre for Tropical Diseases (CTD) in Negrar, Verona, Italy. Biological samples were tested with: stool/urine microscopy, Circulating Cathodic Antigen (CCA) dipstick test, ELISA, Western blot, immune-chromatographic test (ICT). Test accuracy and predictive values of the immunological tests were assessed primarily on the basis of the results of microscopy (primary reference standard): ICT and WB resulted the test with highest sensitivity (94% and 92%, respectively), with a high NPV (98%). CCA showed the highest specificity (93%), but low sensitivity (48%). The analysis was conducted also using a composite reference standard, CRS (patients classified as infected in case of positive microscopy and/or at least 2 concordant positive immunological tests) and Latent Class Analysis (LCA). The latter two models demonstrated excellent agreement (Cohen’s kappa: 0.92) for the classification of the results. In fact, they both confirmed ICT as the test with the highest sensitivity (96%) and NPV (97%), moreover PPV was reasonably good (78% and 72% according to CRS and LCA, respectively). ELISA resulted the most specific immunological test (over 99%). The ICT appears to be a suitable screening test, even when used alone. Conclusions The rapid test ICT was the most sensitive test, with the potential of being used as a single screening test for African migrants. PMID:28582412
The investigation and differential diagnosis of Asperger syndrome in adults.
Lehnhardt, Fritz-Georg; Gawronski, Astrid; Pfeiffer, Kathleen; Kockler, Hanna; Schilbach, Leonhard; Vogeley, Kai
2013-11-08
As a result of the increased public interest in autism spectrum disorders (ASD), certain core manifestations of ASD--impaired social interaction and communication, bizarre interests--are now commonly recognized as being typical of autism, not only in children, but in adults as well. More often than before, general practitioners, neurologists, and psychiatrists find themselves being asked whether a patient is suffering from previously unrecognized Asperger syndrome (AS). The prevalence of ASD is estimated at 1%, and the ratio of diagnosed to undiagnosed cases at about 3:2. Little is known about the diagnostic evaluation of AS in adulthood. We selectively searched the Medline database for pertinent literature, paying special attention to diagnostic manuals and to the guideline of the United Kingdom's National Institute for Health and Care Excellence (NICE). Centrally important aspects of the diagnosis of AS include an assessment of the patient's ability to assume the emotional perspectives of others, non-verbal modes of expression, repetitive behavior patterns, and childhood social behavioral history. The autism quotient (AQ) is now established as a simple but nonspecific screening test. Up to 70% of all affected adults have comorbid disturbances, most often depression and anxiety disorders. The differential diagnosis includes personality disorders, anxiety disorders, obsessive-compulsive disorder, and attention deficit-hyperactivity disorder. The diagnostic assessment should proceed in stepwise fashion, starting from simple screening in primary care and then moving on to evaluation of the suspected diagnosis by a mental health care specialist, followed by extensive further investigation in an outpatient clinic specifically devoted to patients with autism spectrum disorders. The diagnostic assessment of autism in adults requires knowledge of the core and accompanying manifestations of autism and of their differential diagnoses. More research is needed for the development of further screening tests and the precise determination of diagnosis rates, differential diagnoses, nd comorbidities.
Efficiency of the Bethesda System for Thyroid Cytopathology.
Mora-Guzmán, Ismael; Muñoz de Nova, José Luis; Marín-Campos, Cristina; Jiménez-Heffernan, José Antonio; Cuesta Pérez, Juan Julián; Lahera Vargas, Marcos; Torres Mínguez, Emma; Martín-Pérez, Elena
2018-03-28
Fine-needle aspiration biopsies are a key tool for preoperative assessment of thyroid nodules, and the Bethesda system is the preferred method to report cytological analysis. The purpose of this study is to assess the efficiency of the Bethesda system to identify the malignancy risk of thyroid nodules. Patients who underwent thyroid surgery between June 2010 and June 2017 were included. Samples were classified into 6categories according to rates of malignancy associated with each diagnostic category. In order to investigate the correlation between categories, a statistical analysis compared the categories with pathology reports. Diagnostic indicators were calculated as a screening test (categories IV, V, VI as true-positive) and as a method to identify malignancy (V, VI as true-positive). In a series of 522 patients, we found 184 (35.2%) malignant tumours, papillary carcinoma being the most prevalent with 155 cases (84.2%). Malignant rates for diagnostic categories were: I, 0%; II, 1.5%; III, 6.4%; IV, 31%; V, 86.5%; VI, 100%. A robust correlation was identified between categories on statistical analysis. For the «screening test» analysis, sensitivity was 98.9%, specificity 84.4%, positive predictive value 69.6%, negative predictive value 99.5%, and diagnostic accuracy 88.2%. Analysing the accuracy to detect malignancy, values were: sensitivity 98.6%, specificity 97.6%, positive predictive value 93.5%, negative predictive value 99.5%, diagnostic accuracy 97.9%. The Bethesda system is a clear and reliable approach to report thyroid cytology and therefore is an effective tool to identify malignancy risk and guide clinical management. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study
Carnero-Pardo, Cristobal; Gurpegui, Manuel; Sanchez-Cantalejo, Emilio; Frank, Ana; Mola, Santiago; Barquero, M Sagrario; Montoro-Rios, M Teresa
2006-01-01
Background Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. Methods A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn), specificity (Sp) and area under the ROC curves (aROC) with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. Results Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84–0.96), Sp = 0.82 (0.77–0.85), and aROC = 0.93 (0.91–0.95). Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. Conclusion This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity. PMID:16606455
Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E
2009-04-01
The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (< or = 100 microg kg(-1)). Performance in a proficiency test for the detection of sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.
Donofrio, J Joelle; Horeczko, Timothy; Kaji, Amy; Santillanes, Genevieve; Claudius, Ilene
2015-05-01
We examined the patient characteristics and hospital charges associated with routine medical clearance laboratory screening tests in 1,082 children younger than age eighteen who were brought to the emergency department (ED) for involuntary mental health holds--that is, each patient was brought to the ED to be evaluated for being a danger to him- or herself or to others, for being gravely disabled (unable to meet his or her basic needs due to a mental disorder), or both--from July 2009 to December 2010. Testing was performed on 871 of the children; all patients also received a clinical examination. The median charge for blood and urine testing together was $1,235, and the most frequent ordering pattern was the full comprehensive panel of tests. Of the patients with a nonconcerning clinical examination, 94.3 percent also had clinically nonsignificant test results. When we extrapolated cost savings to the national level, omitting routine screening laboratory tests in the population of pediatric patients presenting to the ED on an involuntary psychiatric hold with nonconcerning clinical exams could represent up to $90 million in savings annually, without reducing the ability to screen for emergency medical conditions. Provider-initiated diagnostic testing instead of routine screening would lead to significantly lower charges to the ED and the patient. Project HOPE—The People-to-People Health Foundation, Inc.
Internet-Based Cervical Cytology Screening Program
2005-04-01
and Second Trials of Each Pathologist. * Reference diagnostic category: NEG, ASCUS , LSIL > HSIL Pathologist 1 Interpretation. Negative or LSIL 24 (22...Principal Investigator: David C. Wdlbbur, M.D. Description of Subject Population: Women above the age of l18 years having Pap tests performe PURPOSE We...Subject Population: Women above the age of 18 years having Pay tests performed IRB Protocol Number: 2003P-001658 Sponsor Protocol Number: n/a Consent Form
Adjorlolo, Samuel
2018-06-01
The sociocultural differences between Western and sub-Saharan African countries make it imperative to standardize neuropsychological tests in the latter. However, Western-normed tests are frequently administered in sub-Saharan Africa because of challenges hampering standardization efforts. Yet a salient topical issue in the cross-cultural neuropsychology literature relates to the utility of Western-normed neuropsychological tests in minority groups, non-Caucasians, and by extension Ghanaians. Consequently, this study investigates the diagnostic accuracy, sensitivity, and specificity of executive function (EF) tests (The Stroop Test, Trail Making Test, and Controlled Oral Word Association Test), and a Revised Quick Cognitive Screening Test (RQCST) in a sample of 50 patients diagnosed with moderate traumatic brain injury and 50 healthy controls in Ghana. The EF test scores showed good diagnostic accuracy, with area under the curve (AUC) values of the Trail Making Test scores ranging from .746 to .902. With respect to the Stroop Test scores, the AUC values ranged from .793 to .898, while Controlled Oral Word Association Test had AUC value of .787. The RQCST scores discriminated between the groups, with AUC values ranging from .674 to .912. The AUC values of composite EF score and a neuropsychological score created from EF and RQCST scores were .936 and. 942, respectively. Additionally, the Stroop Test, Trail Making Test, EF composite score, and RQCST scores showed good to excellent sensitivities and specificities. In general, this study has shown that commonly used EF tests in Western countries have diagnostic accuracy, sensitivity, and specificity when administered in Ghanaian samples. The findings and implications of the study are discussed.
Pfundt, Rolph; del Rosario, Marisol; Vissers, Lisenka E.L.M.; Kwint, Michael P.; Janssen, Irene M.; de Leeuw, Nicole; Yntema, Helger G.; Nelen, Marcel R.; Lugtenberg, Dorien; Kamsteeg, Erik-Jan; Wieskamp, Nienke; Stegmann, Alexander P.A.; Stevens, Servi J.C.; Rodenburg, Richard J.T.; Simons, Annet; Mensenkamp, Arjen R.; Rinne, Tuula; Gilissen, Christian; Scheffer, Hans; Veltman, Joris A.; Hehir-Kwa, Jayne Y.
2017-01-01
Purpose: Copy-number variation is a common source of genomic variation and an important genetic cause of disease. Microarray-based analysis of copy-number variants (CNVs) has become a first-tier diagnostic test for patients with neurodevelopmental disorders, with a diagnostic yield of 10–20%. However, for most other genetic disorders, the role of CNVs is less clear and most diagnostic genetic studies are generally limited to the study of single-nucleotide variants (SNVs) and other small variants. With the introduction of exome and genome sequencing, it is now possible to detect both SNVs and CNVs using an exome- or genome-wide approach with a single test. Methods: We performed exome-based read-depth CNV screening on data from 2,603 patients affected by a range of genetic disorders for which exome sequencing was performed in a diagnostic setting. Results: In total, 123 clinically relevant CNVs ranging in size from 727 bp to 15.3 Mb were detected, which resulted in 51 conclusive diagnoses and an overall increase in diagnostic yield of ~2% (ranging from 0 to –5.8% per disorder). Conclusions: This study shows that CNVs play an important role in a broad range of genetic disorders and that detection via exome-based CNV profiling results in an increase in the diagnostic yield without additional testing, bringing us closer to single-test genomics. Genet Med advance online publication 27 October 2016 PMID:28574513
2013-01-01
Background Diagnosis of early-stage hepatocellular carcinoma (HCC) followed by curative resection or liver transplantation offers the best chance for long-term patient survival. Clinically, ultrasonography has suboptimal sensitivity for detecting early-stage HCC. Several serological tests including alpha-fetoprotein (AFP), the ratio of lens culinaris agglutinin-reactive alpha-fetoprotein to total AFP (AFP-L3/AFP), des-gamma carboxyprothrombin (DCP), and glypican-3 (GPC-3) have been widely investigated as diagnostic biomarkers for early-stage HCC in at-risk populations. However, these tests are not recommended for routine HCC screening. Our objective is to determine the diagnostic performance of AFP, AFP-L3/AFP, DCP, and GPC-3 for the detection of HCC, particularly early-stage tumors meeting the Milan criteria. Methods/design We will include cross-sectional studies that consecutively or randomly recruit target populations. We will search the Cochrane Library, Medline, Embase, Science Citation Index, and the Chinese National Knowledge Infrastructure. We will also search the MEDION and ARIF databases to identify diagnostic systematic reviews that include primary studies. Reference lists of relevant reviews will be searched for additional trials. Language restrictions will not be applied. Two reviewers will independently screen study eligibility and extract data. Methodological quality will be assessed according to the revised tool for the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). Two authors will apply the QUADAS-2 assessment to all the included studies, and any discrepancies will be resolved by the third author. The following test characteristics will be extracted into 2 × 2 tables for all included studies: true positives, false positives, true negatives, and false negatives. Study-specific estimates of sensitivity and specificity with 95% confidence intervals will be displayed in forest plots. When possible, we will use the bivariate random-effects model or the Rutter and Gatsonis hierarchical summary receiver operating characteristic model for statistical analysis. To investigate heterogeneity, we will include study designs, population characteristics, test characteristics, and types of reference standard as the study-level variables. Discussion Our systematic review will allow patients, clinicians, and researchers to determine the diagnostic performance of AFP, AFP-L3/AFP, DCP, and GPC-3 for the detection of early-stage HCC and the potential roles of these diagnostic biomarkers in the existing diagnostic pathways. Systematic Review Registration: PROSPERO 2013; CRD42013003879 PMID:23738605
Yiadom, Maame Yaa A B; Mumma, Bryn E; Baugh, Christopher W; Patterson, Brian W; Mills, Angela M; Salazar, Gilberto; Tanski, Mary; Jenkins, Cathy A; Vogus, Timothy J; Miller, Karen F; Jackson, Brittney E; Lehmann, Christoph U; Dorner, Stephen C; West, Jennifer L; Wang, Thomas J; Collins, Sean P; Dittus, Robert S; Bernard, Gordon R; Storrow, Alan B; Liu, Dandan
2018-05-03
Advances in ST-segment elevation myocardial infarction (STEMI) management have involved improving the clinical processes connecting patients with timely emergency cardiovascular care. Screening upon emergency department (ED) arrival for an early ECG to diagnose STEMI, however, is not optimal for all patients. In addition, the degree to which timely screening and diagnosis are associated with improved time to intervention and postpercutaneous coronary intervention outcomes, under more contemporary practice conditions, is not known. We present the methods for a retrospective multicentre cohort study anticipated to include 1220 patients across seven EDs to (1) evaluate the relationship between timely screening and diagnosis with treatment and postintervention clinical outcomes; (2) introduce novel measures for cross-facility performance comparisons of screening and diagnostic care team performance including: door-to-screening, door-to-diagnosis and door-to-catheterisation laboratory arrival times and (3) describe the use of electronic health record data in tandem with an existing disease registry. The completion of this study will provide critical feedback on the quality of screening and diagnostic performance within the contemporary STEMI care pathway that can be used to (1) improve emergency care delivery for patients with STEMI presenting to the ED, (2) present novel metrics for the comparison of screening and diagnostic care and (3) inform the development of screening and diagnostic support tools that could be translated to other care environments. We will disseminate our results via publication and quality performance data sharing with each site. Institutional ethics review approval was received prior to study initiation. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Prenatal screening: current practice, new developments, ethical challenges.
de Jong, Antina; Maya, Idit; van Lith, Jan M M
2015-01-01
Prenatal screening pathways, as nowadays offered in most Western countries consist of similar tests. First, a risk-assessment test for major aneuploides is offered to pregnant women. In case of an increased risk, invasive diagnostic tests, entailing a miscarriage risk, are offered. For decades, only conventional karyotyping was used for final diagnosis. Moreover, several foetal ultrasound scans are offered to detect major congenital anomalies, but the same scans also provide relevant information for optimal support of the pregnancy and the delivery. Recent developments in prenatal screening include the application of microarrays that allow for identifying a much broader range of abnomalities than karyotyping, and non-invasive prenatal testing (NIPT) that enables reducing the number of invasive tests for aneuploidies considerably. In the future, broad NIPT may become possible and affordable. This article will briefly address the ethical issues raised by these technological developments. First, a safe NIPT may lead to routinisation and as such challenge the central issue of informed consent and the aim of prenatal screening: to offer opportunity for autonomous reproductive choice. Widening the scope of prenatal screening also raises the question to what extent 'reproductive autonomy' is meant to expand. Finally, if the same test is used for two different aims, namely detection of foetal anomalies and pregnancy-related problems, non-directive counselling can no longer be taken as a standard. Our broad outline of the ethical issues is meant as an introduction into the more detailed ethical discussions about prenatal screening in the other articles of this special issue. © 2014 John Wiley & Sons Ltd.
Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin
2016-01-01
Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.
Benhalima, Katrien; Mathieu, Chantal; Damm, Peter; Van Assche, André; Devlieger, Roland; Desoye, Gernot; Corcoy, Rosa; Mahmood, Tahir; Nizard, Jacky; Savona-Ventura, Charles; Dunne, Fidelma
2015-07-01
Screening and diagnostic criteria for gestational diabetes (GDM) are inconsistent across Europe, and the development of a uniform GDM screening strategy is necessary. Such a strategy would create opportunities for more women to receive timely treatment for GDM. Developing a consensus on screening for GDM in Europe is challenging, as populations are diverse and healthcare delivery systems also differ. The European Board & College of Obstetrics and Gynaecology (EBCOG) has responded to this challenge by appointing a steering committee, including members of the EBCOG and the Diabetic Pregnancy Study Group (DPSG) associated with the EASD, to develop a proposal for the use of uniform diagnostic criteria for GDM in Europe. A proposal has been developed and has now been approved by the Council of the EBCOG. The current proposal is to screen for overt diabetes at the first prenatal contact using cut-off values for diabetes outside pregnancy, with particular efforts made to screen high-risk groups. When screening for GDM is performed at 24 weeks' gestation or later, the proposal is now to use the 75 g OGTT with the new WHO diagnostic criteria for GDM. However, more research is necessary to evaluate the best GDM screening strategy for different populations in Europe. Therefore, no clear recommendation has been made on whether a universal one-step, two-step or a risk-factor-based screening approach should be used. The use of the same WHO diagnostic GDM criteria across Europe will be an important step towards uniformity.
Marquez-Davila, G; Martinez-Barreda, C E
1985-01-01
Although still controversial, an etiologic role of Gardnerella vaginalis is imputed in vaginitis. Besides isolation of the organism by culture, two alternative diagnostic procedures have been claimed to be useful: the investigation of "clue cells" in clinical specimens and the amine volatilization test or fishy odor perception in genital secretions. Herein we report on the findings of the simultaneous use of G. vaginalis isolation, the clue cell test and amine volatilization perception in specimens from 1,263 consecutive female patients referred to our clinic. Our results show that the simultaneous use of both alternative tests is very useful as a screening procedure. A negative result of both tests predicts a negative culture result in 99% of the cases. However, a positive result of either or both should be considered as an indication to proceed to culture and not as diagnostic of infection. PMID:3878365
Kentala, E; Pyykkö, I; Auramo, Y; Juhola, M
1995-03-01
An interactive database has been developed to assist the diagnostic procedure for vertigo and to store the data. The database offers a possibility to split and reunite the collected information when needed. It contains detailed information about a patient's history, symptoms, and findings in otoneurologic, audiologic, and imaging tests. The symptoms are classified into sets of questions on vertigo (including postural instability), hearing loss and tinnitus, and provoking factors. Confounding disorders are screened. The otoneurologic tests involve saccades, smooth pursuit, posturography, and a caloric test. In addition, findings from specific antibody tests, clinical neurotologic tests, magnetic resonance imaging, brain stem audiometry, and electrocochleography are included. The input information can be applied to workups for vertigo in an expert system called ONE. The database assists its user in that the input of information is easy. If not only can be used for diagnostic purposes but is also beneficial for research, and in combination with the expert system, it provides a tutorial guide for medical students.
AIMING FOR THE BULL'S EYE: The Cost-Utility of Screening for Hydroxychloroquine Retinopathy.
McClellan, Andrew J; Chang, Jonathan S; Smiddy, William E
2016-10-01
Throughout medicine, the cost of various treatments has been increasingly studied with the result that certain management guidelines might be reevaluated in their context. Cost-utility is a term referring to the expense of preventing the loss of quality of life, quantified in dollars per quality-adjusted life year. In 2002, the American Academy of Ophthalmology published hydroxychloroquine screening recommendations which were revised in 2011. The purpose of this report is to estimate the cost-utility of these recommendations. A hypothetical care model of screening for hydroxychloroquine retinopathy was formulated. The costs of screening components were calculated using 2016 Medicare fee schedules from the Centers for Medicare and Medicaid Services. The cost-utility of screening for hydroxychloroquine retinopathy with the 2011 American Academy of Ophthalmology guidelines was found to vary from 33,155 to 344,172 dollars per quality-adjusted life year depending on the type and number of objective screening tests chosen, practice setting, and the duration of hydroxychloroquine use. Screening had a more favorable cost-utility when the more sensitive and specific diagnostics were used, and for patients with an increased risk of toxicity. American Academy of Ophthalmology guidelines have a wide-ranging cost-utility. Prudent clinical judgment of risk stratification and tests chosen is necessary to optimize cost-utility without compromising the efficacy of screening.
Cervical screening in HPV-vaccinated populations.
Canfell, K
2018-06-01
Cervical screening with cytology has been the basis for substantial reductions in cervical cancer incidence and mortality in most high-income countries over the last few decades. More recently, there have been two key, parallel developments which have prompted a major re-consideration of cervical screening. The first is the emergence of evidence on the improved sensitivity of human papillomavirus (HPV) DNA testing compared to cytology, and the second is the large-scale deployment of prophylactic vaccination against HPV. A key challenge to be overcome before HPV screening could be introduced into national cervical screening programs was the specificity of an infection, for detection of precancerous lesions. This has been done in three ways: (1) by considering the appropriate age for starting HPV screening (30 years in unvaccinated populations and 25 years in populations with mature vaccination programs and high vaccine uptake) and the appropriate screening interval; (2) via development of clinical HPV tests, which are (by design) not as sensitive to low viral loads; and (3) by introducing effective triaging for HPV-positive women, which further risk-stratifies women before referral for diagnostic evaluation. This review discusses these major developments and describes how the benefits of HPV screening are being optimized in both unvaccinated and vaccinated populations.
ERIC Educational Resources Information Center
Klingbeil, David A.; Nelson, Peter M.; Van Norman, Ethan R.; Birr, Chris
2017-01-01
We examined the diagnostic accuracy and efficiency of three approaches to universal screening for reading difficulties using retrospective data from 1,307 students in Grades 3 through 5. School staff collected screening data using the Measures of Academic Progress (MAP), a curriculum-based measure (CBM), and running records (RR). The criterion…