Sample records for diagnostic test evaluation

  1. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    PubMed Central

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  2. Pearls and pitfalls of allergy diagnostic testing: report from the American College of Allergy, Asthma and Immunology/American Academy of Allergy, Asthma and Immunology Specific IgE Test Task Force.

    PubMed

    Cox, Linda; Williams, Brock; Sicherer, Scott; Oppenheimer, John; Sher, Larry; Hamilton, Robert; Golden, David

    2008-12-01

    The intended purpose of this monograph is to provide a general overview of allergy diagnostics for health care professionals who care for patients with allergic disease. For a more comprehensive review of allergy diagnostic testing, readers can refer to the Allergy Diagnostic Practice Parameters. A key message is that a positive allergy test result (skin or blood) indicates only the presence of allergen specific IgE (called sensitization). It does not necessarily mean clinical allergy (ie, allergic symptoms with exposure). It is important for this reason that the allergy evaluation be based on the patient's history and directed by a health care professional with sufficient understanding of allergy diagnostic testing to use the information obtained from his/her evaluation of the patient to determine (1) what allergy diagnostic tests to order, (2) how to interpret the allergy diagnostic test results, and (3) how to use the information obtained from the allergy evaluation to develop an appropriate therapeutic treatment plan.

  3. Economic evaluations of point of care testing strategies for active tuberculosis.

    PubMed

    Zwerling, Alice; Dowdy, David

    2013-06-01

    Point of care (POC) diagnostics are often hailed as having the potential to transform tuberculosis (TB) control efforts. However, POC testing is better conceptualized as a system of diagnosis and treatment, not simply a test that can provide rapid, deployable results. Economic evaluations may help decision makers allocate scarce resources for TB control, but evaluations of POC testing face unique challenges that include evaluating the full diagnostic system, incorporating implementation costs, translating diagnostic results into health and accounting for downstream treatment costs. For economic evaluations to reach their full potential as decision-making tools for POC testing in TB, these challenges must be understood and addressed.

  4. Decision analysis to complete diagnostic research by closing the gap between test characteristics and cost-effectiveness.

    PubMed

    Schaafsma, Joanna D; van der Graaf, Yolanda; Rinkel, Gabriel J E; Buskens, Erik

    2009-12-01

    The lack of a standard methodology in diagnostic research impedes adequate evaluation before implementation of constantly developing diagnostic techniques. We discuss the methodology of diagnostic research and underscore the relevance of decision analysis in the process of evaluation of diagnostic tests. Overview and conceptual discussion. Diagnostic research requires a stepwise approach comprising assessment of test characteristics followed by evaluation of added value, clinical outcome, and cost-effectiveness. These multiple goals are generally incompatible with a randomized design. Decision-analytic models provide an important alternative through integration of the best available evidence. Thus, critical assessment of clinical value and efficient use of resources can be achieved. Decision-analytic models should be considered part of the standard methodology in diagnostic research. They can serve as a valid alternative to diagnostic randomized clinical trials (RCTs).

  5. Cheyletiella infestation in the dog: observations on diagnostic methods and clinical signs.

    PubMed

    Saevik, B K; Bredal, W; Ulstein, T L

    2004-10-01

    The aims of this study were to evaluate the ability of diagnostic methods to detect naturally occurring Cheyletiella infestation in dogs, and to quantify and relate the number of mites and eggs present to clinical signs. Privately owned dogs with skin problems were eligible for inclusion in the study. Four diagnostic tests were performed on each dog in the following order: tape impression, hair plucking, skin scraping and vacuum cleaning. Dogs with positive test results for Cheyletiella infestation in at least one of the tests under evaluation were included in the study (n=27). The severity of pruritus and scaling was graded on a four-point fixed scale. The diagnostic findings in vacuum cleaning samples provided a semiquantitative measure of the grade of infestation. The vacuum cleaning test gave a positive test result in all dogs and was significantly more efficient than the other tests evaluated (P<0.01). The number of diagnostic findings varied considerably among the different vacuum samples. No significant relationship between the number of diagnostic findings and severity of clinical signs was detected.

  6. Modeling companion diagnostics in economic evaluations of targeted oncology therapies: systematic review and methodological checklist.

    PubMed

    Doble, Brett; Tan, Marcus; Harris, Anthony; Lorgelly, Paula

    2015-02-01

    The successful use of a targeted therapy is intrinsically linked to the ability of a companion diagnostic to correctly identify patients most likely to benefit from treatment. The aim of this study was to review the characteristics of companion diagnostics that are of importance for inclusion in an economic evaluation. Approaches for including these characteristics in model-based economic evaluations are compared with the intent to describe best practice methods. Five databases and government agency websites were searched to identify model-based economic evaluations comparing a companion diagnostic and subsequent treatment strategy to another alternative treatment strategy with model parameters for the sensitivity and specificity of the companion diagnostic (primary synthesis). Economic evaluations that limited model parameters for the companion diagnostic to only its cost were also identified (secondary synthesis). Quality was assessed using the Quality of Health Economic Studies instrument. 30 studies were included in the review (primary synthesis n = 12; secondary synthesis n = 18). Incremental cost-effectiveness ratios may be lower when the only parameter for the companion diagnostic included in a model is the cost of testing. Incorporating the test's accuracy in addition to its cost may be a more appropriate methodological approach. Altering the prevalence of the genetic biomarker, specific population tested, type of test, test accuracy and timing/sequence of multiple tests can all impact overall model results. The impact of altering a test's threshold for positivity is unknown as it was not addressed in any of the included studies. Additional quality criteria as outlined in our methodological checklist should be considered due to the shortcomings of standard quality assessment tools in differentiating studies that incorporate important test-related characteristics and those that do not. There is a need to refine methods for incorporating the characteristics of companion diagnostics into model-based economic evaluations to ensure consistent and transparent reimbursement decisions are made.

  7. Diagnostic Approach to Acute Diarrheal Illness in a Military Population on Training Exercises in Thailand, a Region of Campylobacter Hyperendemicity▿

    PubMed Central

    Tribble, David R.; Baqar, Shahida; Pang, Lorrin W.; Mason, Carl; Houng, Huo-Shu H.; Pitarangsi, Chittima; Lebron, Carlos; Armstrong, Adam; Sethabutr, Orntipa; Sanders, John W.

    2008-01-01

    High rates of Campylobacter fluoroquinolone resistance highlight the need to evaluate diagnostic strategies that can be used to assist with clinical management. Diagnostic tests were evaluated with U.S. soldiers presenting with acute diarrhea during deployment in Thailand. The results of bedside and field laboratory diagnostic tests were compared to stool microbiology findings for 182 enrolled patients. Campylobacter jejuni was isolated from 62% of the cases. Clinical and laboratory findings at the time of presentation were evaluated to determine their impact on the posttest probability, defined as the likelihood of a diagnosis of Campylobacter infection. Clinical findings, the results of tests for inflammation (stool occult blood testing [Hemoccult], fecal leukocytes, fecal lactoferrin, plasma C-reactive protein), and the numbers of Campylobacter-specific antibody-secreting cells in peripheral blood failed to increase the posttest probability above 90% in this setting of Campylobacter hyperendemicity when these findings were present. Positive results by a Campylobacter-specific commercial enzyme immunoassay (EIA) and, less so, a research PCR were strong positive predictors. The negative predictive value for ruling out Campylobacter infection, defined as a posttest probability of less than 10%, was similarly observed with these Campylobacter-specific stool-based tests as well the fecal leukocyte test. Compared to the other tests evaluated, the Campylobacter EIA is a sensitive and specific rapid diagnostic test that may assist with diagnostic evaluation, with consideration of the epidemiological setting, logistics, and cost. PMID:18234869

  8. Comparing diagnostic tests on benefit-risk.

    PubMed

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  9. Reporting Diagnostic Scores in Educational Testing: Temptations, Pitfalls, and Some Solutions

    ERIC Educational Resources Information Center

    Sinharay, Sandip; Puhan, Gautam; Haberman, Shelby J.

    2010-01-01

    Diagnostic scores are of increasing interest in educational testing due to their potential remedial and instructional benefit. Naturally, the number of educational tests that report diagnostic scores is on the rise, as are the number of research publications on such scores. This article provides a critical evaluation of diagnostic score reporting…

  10. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments.

    PubMed

    Shinkins, Bethany; Yang, Yaling; Abel, Lucy; Fanshawe, Thomas R

    2017-04-14

    Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1) what evidence aside from test accuracy was searched for and synthesised, 2) which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3) how/whether threshold effects were explored, 4) how the potential dependency between multiple tests in a pathway was accounted for, and 5) for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings. The uptake of appropriate meta-analysis methods for synthesising evidence on diagnostic test accuracy in UK NIHR HTAs has improved in recent years. Future research should focus on other evidence requirements for cost-effectiveness assessment, threshold effects for quantitative tests and the impact of multiple diagnostic tests.

  11. Combined evaluation of commonly used techniques, including PCR, for diagnosis of mouse fur mites.

    PubMed

    Karlsson, Eleanor M; Pearson, Laura M; Kuzma, Kristen M; Burkholder, Tanya H

    2014-01-01

    Our study evaluated and compared the false-negative rates (FNR) of a wide array of fur-mite diagnostic tests, including 2 postmortem tests (pelt exam and sticky paper) and 3 antemortem tests (adhesive tape, fur pluck, and PCR). Past publications examining fur-mite diagnostic techniques primarily used paired comparisons, evaluating tests by their level of agreement with only one other test. However, different combinations or pairs of diagnostics are used in the different studies, making the results of these comparisons difficult to interpret across all available diagnostics. In the current study, mice from a conventionally maintained colony endemic for Myobia musculi were identified as positive based on at least one positive diagnostic test. From this pool of positive animals, the FNR of all tests were quantified. The PCR assay and the pelt exam performed the best, with 0% and 2% FNR respectively, whereas tape, fur-pluck, and sticky-paper tests showed 24%, 26%, and 36% FNR, respectively. Our study shows that for mice in a colony naturally infested with Myobia musculi, PCR testing can be used for reliable antemortem detection, and pelt exam performed by experienced examiners is reliable for postmortem detection.

  12. ACER Physics Unit Tests: Unit Tests, Diagnostic Aids, [and] Teachers Handbook.

    ERIC Educational Resources Information Center

    Australian Council for Educational Research, Hawthorn.

    The Physics Unit Tests are designed to assist in the diagnostic evaluation of students' progress in the study of physics during the last two years of secondary schooling. They consist of a collection of 21 separate tests, each related to a different topic, and 21 diagnostic aids corresponding to the tests. The topics covered are: physical…

  13. Special Educator's Complete Guide to 109 Diagnostic Tests: How To Select & Interpret Tests, Use Results in IEPs, and Remediate Specific Difficulties.

    ERIC Educational Resources Information Center

    Pierangelo, Roger; Giuliani, George

    This manual is a guide to the special education diagnostic process and covers the various stages of evaluation, interpretation, diagnosis, prescription, and remediation. Test information includes: explanations of the most commonly used diagnostic tests, coverage of the areas measured by each test, interpretation of test patterns for commonly used…

  14. Systematic Review of Health Economic Evaluations of Diagnostic Tests in Brazil: How accurate are the results?

    PubMed

    Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho

    2017-08-01

    The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.

  15. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference

    PubMed Central

    Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth

    2015-01-01

    Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275

  16. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.

    PubMed

    McInnes, Matthew D F; Moher, David; Thombs, Brett D; McGrath, Trevor A; Bossuyt, Patrick M; Clifford, Tammy; Cohen, Jérémie F; Deeks, Jonathan J; Gatsonis, Constantine; Hooft, Lotty; Hunt, Harriet A; Hyde, Christopher J; Korevaar, Daniël A; Leeflang, Mariska M G; Macaskill, Petra; Reitsma, Johannes B; Rodin, Rachel; Rutjes, Anne W S; Salameh, Jean-Paul; Stevens, Adrienne; Takwoingi, Yemisi; Tonelli, Marcello; Weeks, Laura; Whiting, Penny; Willis, Brian H

    2018-01-23

    Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. The 27-item PRISMA diagnostic test accuracy checklist provides specific guidance for reporting of systematic reviews. The PRISMA diagnostic test accuracy guideline can facilitate the transparent reporting of reviews, and may assist in the evaluation of validity and applicability, enhance replicability of reviews, and make the results from systematic reviews of diagnostic test accuracy studies more useful.

  17. Current approach in the diagnosis and management of posterior uveitis

    PubMed Central

    Sudharshan, S; Ganesh, Sudha K; Biswas, Jyotrimay

    2010-01-01

    Posterior uveitic entities are varied entities that are infective or non-infective in etiology. They can affect the adjacent structures such as the retina, vitreous, optic nerve head and retinal blood vessels. Thorough clinical evaluation gives a clue to the diagnosis while ancillary investigations and laboratory tests assist in confirming the diagnosis. Newer evolving techniques in the investigations and management have increased the diagnostic yield. In case of diagnostic dilemma, intraocular fluid evaluation for polymerase chain testing for the genome and antibody testing against the causative agent provide greater diagnostic ability. PMID:20029144

  18. The Quantitative Science of Evaluating Imaging Evidence.

    PubMed

    Genders, Tessa S S; Ferket, Bart S; Hunink, M G Myriam

    2017-03-01

    Cardiovascular diagnostic imaging tests are increasingly used in everyday clinical practice, but are often imperfect, just like any other diagnostic test. The performance of a cardiovascular diagnostic imaging test is usually expressed in terms of sensitivity and specificity compared with the reference standard (gold standard) for diagnosing the disease. However, evidence-based application of a diagnostic test also requires knowledge about the pre-test probability of disease, the benefit of making a correct diagnosis, the harm caused by false-positive imaging test results, and potential adverse effects of performing the test itself. To assist in clinical decision making regarding appropriate use of cardiovascular diagnostic imaging tests, we reviewed quantitative concepts related to diagnostic performance (e.g., sensitivity, specificity, predictive values, likelihood ratios), as well as possible biases and solutions in diagnostic performance studies, Bayesian principles, and the threshold approach to decision making. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. Evaluating a mobile application for improving clinical laboratory test ordering and diagnosis.

    PubMed

    Meyer, Ashley N D; Thompson, Pamela J; Khanna, Arushi; Desai, Samir; Mathews, Benji K; Yousef, Elham; Kusnoor, Anita V; Singh, Hardeep

    2018-04-20

    Mobile applications for improving diagnostic decision making often lack clinical evaluation. We evaluated if a mobile application improves generalist physicians' appropriate laboratory test ordering and diagnosis decisions and assessed if physicians perceive it as useful for learning. In an experimental, vignette study, physicians diagnosed 8 patient vignettes with normal prothrombin times (PT) and abnormal partial thromboplastin times (PTT). Physicians made test ordering and diagnosis decisions for 4 vignettes using each resource: a mobile app, PTT Advisor, developed by the Centers for Disease Control and Prevention (CDC)'s Clinical Laboratory Integration into Healthcare Collaborative (CLIHC); and usual clinical decision support. Then, physicians answered questions regarding their perceptions of the app's usefulness for diagnostic decision making and learning using a modified Kirkpatrick Training Evaluation Framework. Data from 368 vignettes solved by 46 physicians at 7 US health care institutions show advantages for using PTT Advisor over usual clinical decision support on test ordering and diagnostic decision accuracy (82.6 vs 70.2% correct; P < .001), confidence in decisions (7.5 vs 6.3 out of 10; P < .001), and vignette completion time (3:02 vs 3:53 min.; P = .06). Physicians reported positive perceptions of the app's potential for improved clinical decision making, and recommended it be used to address broader diagnostic challenges. A mobile app, PTT Advisor, may contribute to better test ordering and diagnosis, serve as a learning tool for diagnostic evaluation of certain clinical disorders, and improve patient outcomes. Similar methods could be useful for evaluating apps aimed at improving testing and diagnosis for other conditions.

  20. Towards improving diagnosis of memory loss in general practice: TIMeLi diagnostic test accuracy study protocol.

    PubMed

    Creavin, Sam T; Cullum, Sarah J; Haworth, Judy; Wye, Lesley; Bayer, Antony; Fish, Mark; Purdy, Sarah; Ben-Shlomo, Yoav

    2016-07-19

    People with cognitive problems, and their families, report distress and uncertainty whilst undergoing evaluation for dementia and perceive that traditional diagnostic evaluation in secondary care is insufficiently patient centred. The James Lind Alliance has prioritised research to investigate the role of primary care in supporting a more effective diagnostic pathway, and the topic is also of interest to health commissioners. However, there are very few studies that investigate the accuracy of diagnostic tests for dementia in primary care. We will conduct a prospective diagnostic test accuracy study to evaluate the accuracy of a range of simple tests for diagnosing all-cause-dementia in symptomatic people aged over 70 years who have consulted with their general practitioner (GP). We will invite eligible people to attend a research clinic where they will undergo a range of index tests that a GP could perform in the surgery and also be assessed by a specialist in memory disorders at the same appointment. Participating GPs will request neuroimaging and blood tests and otherwise manage patients in line with their usual clinical practice. The reference standard will be the consensus judgement of three experts (neurologist, psychiatrist and geriatrician) based on information from the specialist assessment, GP records and investigations, but not including items in the index test battery. The target condition will be all-cause dementia but we will also investigate diagnostic accuracy for sub-types where possible. We will use qualitative interviews with patients and focus groups with clinicians to help us understand the acceptability and feasibility of diagnosing dementia in primary care using the tests that we are investigating. Our results will help clinicians decide on which tests to perform in someone where there is concern about possible dementia and inform commissioning of diagnostic pathways.

  1. Effects of Training on the Test of Diagnostic Skills. Publication No. 30.

    ERIC Educational Resources Information Center

    Haley, John V.

    This report summarizes research performed on the Test of Diagnostic Skills, used to evaluate the clinical diagnostic skills of medical students. Forms of the test were administered to groups at different levels of medical experience to ascertain the effect of training on performance. A cross-sectional study was conducted with approximately 90…

  2. Diagnostic testing.

    PubMed

    Brewer, D E

    2000-09-01

    The results of cardiac tests must always be interpreted through the lens of pretest probabilities created by the history and the physical examination. Tests should be chosen with a clear diagnostic and prognostic purpose in mind. A clear understanding of the relationship between the history and physical examination and more technologic diagnostic testing improves the primary care physician's ability to evaluate potential cardiac disease in an efficient and cost-effective manner.

  3. Quality and reporting of diagnostic accuracy studies in TB, HIV and malaria: evaluation using QUADAS and STARD standards.

    PubMed

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-11-13

    Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004-2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.

  4. Quality and Reporting of Diagnostic Accuracy Studies in TB, HIV and Malaria: Evaluation Using QUADAS and STARD Standards

    PubMed Central

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-01-01

    Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases. PMID:19915664

  5. Advances Afoot in Microbiology

    PubMed Central

    Karon, Brad S.

    2017-01-01

    ABSTRACT In 2016, the American Academy of Microbiology convened a colloquium to examine point-of-care (POC) microbiology testing and to evaluate its effects on clinical microbiology. Colloquium participants included representatives from clinical microbiology laboratories, industry, and the government, who together made recommendations regarding the implementation, oversight, and evaluation of POC microbiology testing. The colloquium report is timely and well written (V. Dolen et al., Changing Diagnostic Paradigms for Microbiology, 2017, https://www.asm.org/index.php/colloquium-reports/item/6421-changing-diagnostic-paradigms-for-microbiology?utm_source=Commentary&utm_medium=referral&utm_campaign=diagnostics). Emerging POC microbiology tests, especially nucleic acid amplification tests, have the potential to advance medical care. PMID:28539341

  6. 20 CFR 404.1519m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DISABILITY INSURANCE (1950- ) Determining Disability and Blindness Standards for the Type of Referral and for Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic..., arteriograms, or cardiac catheterizations for the evaluation of disability under the Social Security program. A...

  7. Improvement in the Diagnostic Evaluation of a Positive Fecal Occult Blood Test in an Integrated Health Care Organization

    PubMed Central

    Miglioretti, Diana L.; Rutter, Carolyn M.; Bradford, Susan Carol; Zauber, Ann G.; Kessler, Larry G.; Feuer, Eric J.; Grossman, David C.

    2014-01-01

    Background Screening for fecal occult blood can be effective in reducing colorectal cancer mortality only if positive tests are appropriately followed up with complete diagnostic evaluation (i.e., colonoscopy or flexible sigmoidoscopy with double contrast barium enema) and treatment. Objectives To examine whether rates of complete diagnostic evaluation following a positive fecal occult blood test (FOBT) have improved over time after the implementation of tracking systems and physician guidelines within a large integrated health care organization. Research Design From 1993 to 2005, 8513 positive FOBTs were identified on 8291 enrollees aged 50–79 of a large health care system. Automated records were used to identify repeat FOBTs, colonoscopy, flexible sigmoidoscopy, and double-contrast barium enema within one year after the positive FOBT. National rates of complete diagnostic evaluation were estimated from the 2005 National Health Interview Survey. Results In this integrated health care organization, the percentage of positive FOBTs followed by complete diagnostic evaluation within one year increased from 57%–64% in 1993–1996 to 82%–86% from 2000–2005. Use of repeat FOBT following a positive FOBT decreased from 28–31% in 1993–1996 to 6–11% in 2000–2005. Based on the National Health Interview Survey, only 52% of positive FOBTs from 2000–2005 were followed by complete diagnostic evaluation nationally. Conclusions Adherence to recommendations for complete diagnostic evaluation following a positive FOBT has greatly improved over time in an integrated group medical practice. Through the use of tracking systems and screening guidelines, it may be possible to reach levels of follow-up that are comparable to those observed in randomized trials. PMID:18725839

  8. Study on validity of a rapid diagnostic test kit versus light microscopy for malaria diagnosis in Ahmedabad city, India.

    PubMed

    Vyas, S; Puwar, B; Patel, V; Bhatt, G; Kulkarni, S; Fancy, M

    2014-05-01

    Light microscopy of blood smears for diagnosis of malaria in the field has several limitations, notably delays in diagnosis. This study in Ahmedabad in Gujarat State, India, evaluated the diagnostic performance of a rapid diagnostic test for malaria (SD Bioline Malaria Ag P.f/Pan) versus blood smear examination as the gold standard. All fever cases presenting at 13 urban health centres were subjected to rapid diagnostic testing and thick and thin blood smears. A total of 677 cases with fever were examined; 135 (20.0%) tested positive by rapid diagnostic test and 86 (12.7%) by blood smear. The sensitivity of the rapid diagnostic test for malaria was 98.8%, specificity was 91.5%, positive predictive value 63.0% and negative predictive value 99.8%. For detection of Plasmodium falciparum the sensitivity of rapid diagnostic test was 100% and specificity was 97.3%. The results show the acceptability of the rapid test as an alternative to light microscopy in the field setting.

  9. Psychometric Analysis of the Diagnostic Evaluation of Language Variation-Screening Test: Extension to Low-Income African American Pre-Kindergarteners

    ERIC Educational Resources Information Center

    Terry, Nicole P.; Petscher, Yaacov; Rhodes, Katherine T.

    2017-01-01

    The purpose of this study was to extend a previous investigation of the psychometrics of the "Diagnostic Evaluation of Language Variation-Screening Test" (DELV-S) to include pre-kindergarten children (primarily African American and from low-income households). The previous study (Petscher, Connor, & Al Otaiba, 2012) included a…

  10. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    PubMed

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  11. Advances Afoot in Microbiology.

    PubMed

    Patel, Robin; Karon, Brad S

    2017-07-01

    In 2016, the American Academy of Microbiology convened a colloquium to examine point-of-care (POC) microbiology testing and to evaluate its effects on clinical microbiology. Colloquium participants included representatives from clinical microbiology laboratories, industry, and the government, who together made recommendations regarding the implementation, oversight, and evaluation of POC microbiology testing. The colloquium report is timely and well written (V. Dolen et al., Changing Diagnostic Paradigms for Microbiology , 2017, https://www.asm.org/index.php/colloquium-reports/item/6421-changing-diagnostic-paradigms-for-microbiology?utm_source=Commentary&utm_medium=referral&utm_campaign=diagnostics). Emerging POC microbiology tests, especially nucleic acid amplification tests, have the potential to advance medical care. Copyright © 2017 American Society for Microbiology.

  12. Development, Evaluation, and Integration of a Quantitative Reverse-Transcription Polymerase Chain Reaction Diagnostic Test for Ebola Virus on a Molecular Diagnostics Platform

    PubMed Central

    Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B.; Nauwelaers, David; Ariën, Kevin K.

    2016-01-01

    Background. The 2013–2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV). Methods. The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus. Results. The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%. Conclusions. The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. PMID:27247341

  13. How does study quality affect the results of a diagnostic meta-analysis?

    PubMed Central

    Westwood, Marie E; Whiting, Penny F; Kleijnen, Jos

    2005-01-01

    Background The use of systematic literature review to inform evidence based practice in diagnostics is rapidly expanding. Although the primary diagnostic literature is extensive, studies are often of low methodological quality or poorly reported. There has been no rigorously evaluated, evidence based tool to assess the methodological quality of diagnostic studies. The primary objective of this study was to determine the extent to which variations in the quality of primary studies impact the results of a diagnostic meta-analysis and whether this differs with diagnostic test type. A secondary objective was to contribute to the evaluation of QUADAS, an evidence-based tool for the assessment of quality in diagnostic accuracy studies. Methods This study was conducted as part of large systematic review of tests used in the diagnosis and further investigation of urinary tract infection (UTI) in children. All studies included in this review were assessed using QUADAS, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. The impact of individual components of QUADAS on a summary measure of diagnostic accuracy was investigated using regression analysis. The review divided the diagnosis and further investigation of UTI into the following three clinical stages: diagnosis of UTI, localisation of infection, and further investigation of the UTI. Each stage used different types of diagnostic test, which were considered to involve different quality concerns. Results Many of the studies included in our review were poorly reported. The proportion of QUADAS items fulfilled was similar for studies in different sections of the review. However, as might be expected, the individual items fulfilled differed between the three clinical stages. Regression analysis found that different items showed a strong association with test performance for the different tests evaluated. These differences were observed both within and between the three clinical stages assessed by the review. The results of regression analyses were also affected by whether or not a weighting (by sample size) was applied. Our analysis was severely limited by the completeness of reporting and the differences between the index tests evaluated and the reference standards used to confirm diagnoses in the primary studies. Few tests were evaluated by sufficient studies to allow meaningful use of meta-analytic pooling and investigation of heterogeneity. This meant that further analysis to investigate heterogeneity could only be undertaken using a subset of studies, and that the findings are open to various interpretations. Conclusion Further work is needed to investigate the influence of methodological quality on the results of diagnostic meta-analyses. Large data sets of well-reported primary studies are needed to address this question. Without significant improvements in the completeness of reporting of primary studies, progress in this area will be limited. PMID:15943861

  14. Diagnosis of aphasia in stroke populations: A systematic review of language tests

    PubMed Central

    2018-01-01

    Background and purpose Accurate aphasia diagnosis is important in stroke care. A wide range of language tests are available and include informal assessments, tests developed by healthcare institutions and commercially published tests available for purchase in pre-packaged kits. The psychometrics of these tests are often reported online or within the purchased test manuals, not the peer-reviewed literature, therefore the diagnostic capabilities of these measures have not been systematically evaluated. This review aimed to identify both commercial and non-commercial language tests and tests used in stroke care and to examine the diagnostic capabilities of all identified measures in diagnosing aphasia in stroke populations. Methods Language tests were identified through a systematic search of 161 publisher databases, professional and resource websites and language tests reported to be used in stroke care. Two independent reviewers evaluated test manuals or associated resources for cohort or cross-sectional studies reporting the tests’ diagnostic capabilities (sensitivity, specificity, likelihood ratios or diagnostic odds ratios) in differentiating aphasic and non-aphasic stroke populations. Results Fifty-six tests met the study eligibility criteria. Six “non-specialist” brief screening tests reported sensitivity and specificity information, however none of these measures reported to meet the specific diagnostic needs of speech pathologists. The 50 remaining measures either did not report validity data (n = 7); did not compare patient test performance with a comparison group (n = 17); included non-stroke participants within their samples (n = 23) or did not compare stroke patient performance against a language reference standard (n = 3). Diagnostic sensitivity analysis was completed for six speech pathology measures (WAB, PICA, CADL-2, ASHA-FACS, Adult FAVRES and EFA-4), however all studies compared aphasic performance with that of non-stroke healthy controls and were consequently excluded from the review. Conclusions No speech pathology test was found which reported diagnostic data for identifying aphasia in stroke populations. A diagnostically validated post-stroke aphasia test is needed. PMID:29566043

  15. Development and Use of Diagnostic Tests to Evaluate Students' Misconceptions in Science.

    ERIC Educational Resources Information Center

    Treagust, David F.

    1988-01-01

    Describes 10 steps for developing a diagnostic test of students' misconceptions and the use of two tests in chemistry (covalent bonding and structure) and in biology (photosynthesis and respiration in plants). Discusses the results and some implications for teaching science. (YP)

  16. Malaria Diagnostics in Clinical Trials

    PubMed Central

    Murphy, Sean C.; Shott, Joseph P.; Parikh, Sunil; Etter, Paige; Prescott, William R.; Stewart, V. Ann

    2013-01-01

    Malaria diagnostics are widely used in epidemiologic studies to investigate natural history of disease and in drug and vaccine clinical trials to exclude participants or evaluate efficacy. The Malaria Laboratory Network (MLN), managed by the Office of HIV/AIDS Network Coordination, is an international working group with mutual interests in malaria disease and diagnosis and in human immunodeficiency virus/acquired immunodeficiency syndrome clinical trials. The MLN considered and studied the wide array of available malaria diagnostic tests for their suitability for screening trial participants and/or obtaining study endpoints for malaria clinical trials, including studies of HIV/malaria co-infection and other malaria natural history studies. The MLN provides recommendations on microscopy, rapid diagnostic tests, serologic tests, and molecular assays to guide selection of the most appropriate test(s) for specific research objectives. In addition, this report provides recommendations regarding quality management to ensure reproducibility across sites in clinical trials. Performance evaluation, quality control, and external quality assessment are critical processes that must be implemented in all clinical trials using malaria tests. PMID:24062484

  17. Health Technology Assessment for Molecular Diagnostics: Practices, Challenges, and Recommendations from the Medical Devices and Diagnostics Special Interest Group.

    PubMed

    Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael

    2016-01-01

    Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA stakeholders, clearer links between HTA and funding decisions, explicit recognition of and rationale for differential approaches to laboratory-developed versus regulatory-approved test, and clear evidence requirements. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  18. Propulsion Diagnostic Method Evaluation Strategy (ProDiMES) User's Guide

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2010-01-01

    This report is a User's Guide for the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES). ProDiMES is a standard benchmarking problem and a set of evaluation metrics to enable the comparison of candidate aircraft engine gas path diagnostic methods. This Matlab (The Mathworks, Inc.) based software tool enables users to independently develop and evaluate diagnostic methods. Additionally, a set of blind test case data is also distributed as part of the software. This will enable the side-by-side comparison of diagnostic approaches developed by multiple users. The Users Guide describes the various components of ProDiMES, and provides instructions for the installation and operation of the tool.

  19. More Than Just Accuracy: A Novel Method to Incorporate Multiple Test Attributes in Evaluating Diagnostic Tests Including Point of Care Tests.

    PubMed

    Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole

    2016-01-01

    Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.

  20. Emergency coronary angioplasty with stenting using Cordis® diagnostic coronary catheters when there is difficulty in engaging guide catheters and bench evaluation of diagnostic and guide catheters.

    PubMed

    Arokiaraj, Mark Christopher

    2018-02-01

    Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Use of objective testing in the diagnosis of work-related asthma by physician specialty.

    PubMed

    Curwick, Christy C; Bonauto, David K; Adams, Darrin A

    2006-10-01

    Although early and accurate diagnosis of work-related asthma is critical to avoid unnecessary medical, legal, social, and economic consequences, little is currently known about the diagnostic practices of physicians treating workers with work-related asthma. To characterize the use of objective diagnostic testing for work-related asthma by physician specialty. A cross-sectional, descriptive, comparative evaluation was conducted of 301 workers' compensation claimants with work-related asthma. A few claimants (36.9%) were treated by specialists in work-related asthma (allergists, pulmonologists, or occupational medicine physicians) either initially or through the course of their claim. Workers with occupational asthma were more likely to have seen a specialist than those with work-aggravated asthma (47.9% vs 23.0%; P < .001). Less than half of the claimants with work-related asthma (43.2%) had received an objective evaluation of pulmonary function, through either pulmonary function testing or testing for reversible airflow limitation, for the evaluation of their work-related asthma. Claimants treated by specialists were significantly more likely to have received diagnostic testing during evaluation of their disease than those treated solely by generalists (82.9% vs 20.0%; P < .001). The results of this study point to the lack of appropriate diagnostic care received by workers with work-related asthma. Physicians who may have questions about diagnostic procedures should consider referral to a specialist. The development of referral networks for work-related asthma may be warranted and should be explored.

  2. Methods Used in Economic Evaluations of Testing and Diagnosis for Ovarian Cancer: A Systematic Review.

    PubMed

    Sharma, Vishal; Sundar, Sudha S; Breheny, Katie; Monahan, Mark; Sutton, Andrew John

    2016-06-01

    There are multiple tests available that can help diagnose ovarian cancer, and the cost-effective analysis of these diagnostic interventions is essential for making well-informed decisions regarding resource allocation. There are multiple factors that can impact on the conclusions drawn from economic evaluations including test accuracy, the impact of the testing pathway on patient costs and outcomes, and delays along the ovarian cancer test-treat pathway. The objective of this study was to evaluate how test accuracy, the choice of perspective, and delays along the testing and diagnostic pathway have been incorporated in economic evaluations of testing for ovarian cancer. A systematic review of published literature was undertaken to identify economic evaluations (eg, cost-effectiveness, cost-utility analysis) focused on testing and diagnosis for ovarian cancer. Seven studies met the inclusion criteria. Six studies incorporated test accuracy and its impact on patients to some extent. Four studies adopted a societal perspective, but only one considered the costs incurred by patients on the testing and diagnosis pathway. Where delays on the testing pathway were incorporated into the analysis, these were frequently due to false-negative test results leading to delays in patients accessing treatment. Any anxiety that patients might experience as a result of a positive test was not considered in these studies. The impact on patients of receiving a positive test in terms of anxiety and the costs incurred by patients having to attend for testing and diagnosis are rarely considered. Delays along the testing and diagnosis pathway can have a major effect on patient outcomes, and it is important that these are acknowledged in economic evaluations focused on testing. Future economic analysis should incorporate these key determinants in order that diagnostic tests for ovarian cancer can be robustly evaluated.

  3. Cognitive Diagnostic Models for Tests with Multiple-Choice and Constructed-Response Items

    ERIC Educational Resources Information Center

    Kuo, Bor-Chen; Chen, Chun-Hua; Yang, Chih-Wei; Mok, Magdalena Mo Ching

    2016-01-01

    Traditionally, teachers evaluate students' abilities via their total test scores. Recently, cognitive diagnostic models (CDMs) have begun to provide information about the presence or absence of students' skills or misconceptions. Nevertheless, CDMs are typically applied to tests with multiple-choice (MC) items, which provide less diagnostic…

  4. DECIDE: a software for computer-assisted evaluation of diagnostic test performance.

    PubMed

    Chiecchio, A; Bo, A; Manzone, P; Giglioli, F

    1993-05-01

    The evaluation of the performance of clinical tests is a complex problem involving different steps and many statistical tools, not always structured in an organic and rational system. This paper presents a software which provides an organic system of statistical tools helping evaluation of clinical test performance. The program allows (a) the building and the organization of a working database, (b) the selection of the minimal set of tests with the maximum information content, (c) the search of the model best fitting the distribution of the test values, (d) the selection of optimal diagnostic cut-off value of the test for every positive/negative situation, (e) the evaluation of performance of the combinations of correlated and uncorrelated tests. The uncertainty associated with all the variables involved is evaluated. The program works in a MS-DOS environment with EGA or higher performing graphic card.

  5. Development, Evaluation, and Integration of a Quantitative Reverse-Transcription Polymerase Chain Reaction Diagnostic Test for Ebola Virus on a Molecular Diagnostics Platform.

    PubMed

    Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B; Nauwelaers, David; Ariën, Kevin K

    2016-10-15

     The 2013-2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV).  The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus.  The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%.  The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  6. Molecular malaria diagnostics: A systematic review and meta-analysis.

    PubMed

    Roth, Johanna M; Korevaar, Daniël A; Leeflang, Mariska M G; Mens, Pètra F

    2016-01-01

    Accurate diagnosis of malaria is essential for identification and subsequent treatment of the disease. Currently, microscopy and rapid diagnostic tests are the most commonly used diagnostics, next to treatment based on clinical signs only. These tests are easy to deploy, but have a relatively high detection limit. With declining prevalence in many areas, there is an increasing need for more sensitive diagnostics. Molecular tools may be a suitable alternative, although costs and technical requirements currently hamper their implementation in resource limited settings. A range of (near) point-of-care diagnostics is therefore under development, including simplifications in sample preparation, amplification and/or read-out of the test. Accuracy data, in combination with technical characteristics, are essential in determining which molecular test, if any, would be the most promising to be deployed. This review presents a comprehensive overview of the currently available molecular malaria diagnostics, ranging from well-known tests to platforms in early stages of evaluation, and systematically evaluates their published accuracy. No important difference in accuracy was found between the most commonly used PCR-based assays (conventional, nested and real-time PCR), with most of them having high sensitivity and specificity, implying that there are no reasons other than practical ones to choose one technique over the other. Loop-mediated isothermal amplification and other (novel) diagnostics appear to be highly accurate as well, with some offering potential to be used in resource-limited settings.

  7. A novel modification of the Turing test for artificial intelligence and robotics in healthcare.

    PubMed

    Ashrafian, Hutan; Darzi, Ara; Athanasiou, Thanos

    2015-03-01

    The increasing demands of delivering higher quality global healthcare has resulted in a corresponding expansion in the development of computer-based and robotic healthcare tools that rely on artificially intelligent technologies. The Turing test was designed to assess artificial intelligence (AI) in computer technology. It remains an important qualitative tool for testing the next generation of medical diagnostics and medical robotics. Development of quantifiable diagnostic accuracy meta-analytical evaluative techniques for the Turing test paradigm. Modification of the Turing test to offer quantifiable diagnostic precision and statistical effect-size robustness in the assessment of AI for computer-based and robotic healthcare technologies. Modification of the Turing test to offer robust diagnostic scores for AI can contribute to enhancing and refining the next generation of digital diagnostic technologies and healthcare robotics. Copyright © 2014 John Wiley & Sons, Ltd.

  8. AST Combustion Workshop: Diagnostics Working Group Report

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Hanson, Ronald K.

    1996-01-01

    A workshop was convened under NASA's Advanced Subsonics Technologies (AST) Program. Many of the principal combustion diagnosticians from industry, academia, and government laboratories were assembled in the Diagnostics/Testing Subsection of this workshop to discuss the requirements and obstacles to the successful implementation of advanced diagnostic techniques to the test environment of the proposed AST combustor. The participants, who represented the major relevant areas of advanced diagnostic methods currently applied to combustion and related fields, first established the anticipated AST combustor flowfield conditions. Critical flow parameters were then examined and prioritized as to their importance to combustor/fuel injector design and manufacture, environmental concerns, and computational interests. Diagnostic techniques were then evaluated in terms of current status, merits and obstacles for each flow parameter. All evaluations are presented in tabular form and recommendations are made on the best-suited diagnostic method to implement for each flow parameter in order of applicability and intrinsic value.

  9. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    PubMed

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  10. Rapid diagnostic tests for malaria

    PubMed Central

    Daily, Jennifer; Hotte, Nora; Dolkart, Caitlin; Cunningham, Jane; Yadav, Prashant

    2015-01-01

    Abstract Maintaining quality, competitiveness and innovation in global health technology is a constant challenge for manufacturers, while affordability, access and equity are challenges for governments and international agencies. In this paper we discuss these issues with reference to rapid diagnostic tests for malaria. Strategies to control and eliminate malaria depend on early and accurate diagnosis. Rapid diagnostic tests for malaria require little training and equipment and can be performed by non-specialists in remote settings. Use of these tests has expanded significantly over the last few years, following recommendations to test all suspected malaria cases before treatment and the implementation of an evaluation programme to assess the performance of the malaria rapid diagnostic tests. Despite these gains, challenges exist that, if not addressed, could jeopardize the progress made to date. We discuss recent developments in rapid diagnostic tests for malaria, highlight some of the challenges and provide suggestions to address them. PMID:26668438

  11. Validation of Ten Noninvasive Diagnostic Models for Prediction of Liver Fibrosis in Patients with Chronic Hepatitis B

    PubMed Central

    Cheng, Jieyao; Hou, Jinlin; Ding, Huiguo; Chen, Guofeng; Xie, Qing; Wang, Yuming; Zeng, Minde; Ou, Xiaojuan; Ma, Hong; Jia, Jidong

    2015-01-01

    Background and Aims Noninvasive models have been developed for fibrosis assessment in patients with chronic hepatitis B. However, the sensitivity, specificity and diagnostic accuracy in evaluating liver fibrosis of these methods have not been validated and compared in the same group of patients. The aim of this study was to verify the diagnostic performance and reproducibility of ten reported noninvasive models in a large cohort of Asian CHB patients. Methods The diagnostic performance of ten noninvasive models (HALF index, FibroScan, S index, Zeng model, Youyi model, Hui model, APAG, APRI, FIB-4 and FibroTest) was assessed against the liver histology by ROC curve analysis in CHB patients. The reproducibility of the ten models were evaluated by recalculating the diagnostic values at the given cut-off values defined by the original studies. Results Six models (HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest) had AUROCs higher than 0.70 in predicting any fibrosis stage and 2 of them had best diagnostic performance with AUROCs to predict F≥2, F≥3 and F4 being 0.83, 0.89 and 0.89 for HALF index, 0.82, 0.87 and 0.87 for FibroScan, respectively. Four models (HALF index, FibroScan, Zeng model and Youyi model) showed good diagnostic values at given cut-offs. Conclusions HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest show a good diagnostic performance and all of them, except S index and FibroTest, have good reproducibility for evaluating liver fibrosis in CHB patients. Registration Number ChiCTR-DCS-07000039. PMID:26709706

  12. The 2016 Academic Emergency Medicine Consensus Conference, "Shared Decision Making in the Emergency Department: Development of a Policy-relevant Patient-centered Research Agenda" Diagnostic Testing Breakout Session Report.

    PubMed

    Barrett, Tyler W; Rising, Kristin L; Bellolio, M Fernanda; Hall, M Kennedy; Brody, Aaron; Dodd, Kenneth W; Grieser, Mira; Levy, Phillip D; Raja, Ali S; Self, Wesley H; Weingarten, Gail; Hess, Erik P; Hollander, Judd E

    2016-12-01

    Diagnostic testing is an integral component of patient evaluation in the emergency department (ED). Emergency clinicians frequently use diagnostic testing to more confidently exclude "worst-case" diagnoses rather than to determine the most likely etiology for a presenting complaint. Increased utilization of diagnostic testing has not been associated with reductions in disease-related mortality but has led to increased overall healthcare costs and other unintended consequences (e.g., incidental findings requiring further workup, unnecessary exposure to ionizing radiation or potentially nephrotoxic contrast). Shared decision making (SDM) presents an opportunity for clinicians to discuss the benefits and harms associated with diagnostic testing with patients to more closely tailor testing to patient risk. This article introduces the challenges and opportunities associated with incorporating SDM into emergency care by summarizing the conclusions of the diagnostic testing group at the 2016 Academic Emergency Medicine Consensus Conference on SDM. Three primary domains emerged: 1) characteristics of a condition or test appropriate for SDM, 2) critical elements of and potential barriers to SDM discussions on diagnostic testing, and 3) financial aspects of SDM applied to diagnostic testing. The most critical research questions to improve engagement of patients in their acute care diagnostic decisions were determined by consensus. © 2016 by the Society for Academic Emergency Medicine.

  13. System Related Interventions to Reduce Diagnostic Error: A Narrative Review

    PubMed Central

    Singh, Hardeep; Graber, Mark L.; Kissam, Stephanie M.; Sorensen, Asta V.; Lenfestey, Nancy F.; Tant, Elizabeth M.; Henriksen, Kerm; LaBresh, Kenneth A.

    2013-01-01

    Background Diagnostic errors (missed, delayed, or wrong diagnosis) have gained recent attention and are associated with significant preventable morbidity and mortality. We reviewed the recent literature to identify interventions that have been, or could be, implemented to address systems-related factors that contribute directly to diagnostic error. Methods We conducted a comprehensive search using multiple search strategies. We first identified candidate articles in English between 2000 and 2009 from a PubMed search that exclusively evaluated for articles related to diagnostic error or delay. We then sought additional papers from references in the initial dataset, searches of additional databases, and subject matter experts. Articles were included if they formally evaluated an intervention to prevent or reduce diagnostic error; however, we also included papers if interventions were suggested and not tested in order to inform the state-of-the science on the topic. We categorized interventions according to the step in the diagnostic process they targeted: patient-provider encounter, performance and interpretation of diagnostic tests, follow-up and tracking of diagnostic information, subspecialty and referral-related; and patient-specific. Results We identified 43 articles for full review, of which 6 reported tested interventions and 37 contained suggestions for possible interventions. Empirical studies, though somewhat positive, were non-experimental or quasi-experimental and included a small number of clinicians or health care sites. Outcome measures in general were underdeveloped and varied markedly between studies, depending on the setting or step in the diagnostic process involved. Conclusions Despite a number of suggested interventions in the literature, few empirical studies have tested interventions to reduce diagnostic error in the last decade. Advancing the science of diagnostic error prevention will require more robust study designs and rigorous definitions of diagnostic processes and outcomes to measure intervention effects. PMID:22129930

  14. Psychoacoustic Assessment of Speech Communication Systems. The Diagnostic Discrimination Test.

    ERIC Educational Resources Information Center

    Grether, Craig Blaine

    The present report traces the rationale, development and experimental evaluation of the Diagnostic Discrimination Test (DDT). The DDT is a three-choice test of consonant discriminability of the perceptual/acoustic dimensions of consonant phonemes within specific vowel contexts. The DDT was created and developed in an attempt to provide a…

  15. Diagnostic value of tendon thickness and structure in the sonographic diagnosis of supraspinatus tendinopathy: room for a two-step approach.

    PubMed

    Arend, Carlos Frederico; Arend, Ana Amalia; da Silva, Tiago Rodrigues

    2014-06-01

    The aim of our study was to systematically compare different methodologies to establish an evidence-based approach based on tendon thickness and structure for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. US was obtained from 164 symptomatic patients with supraspinatus tendinopathy detected at MRI and 42 asymptomatic controls with normal MRI. Diagnostic yield was calculated for either maximal supraspinatus tendon thickness (MSTT) and tendon structure as isolated criteria and using different combinations of parallel and sequential testing at US. Chi-squared tests were performed to assess sensitivity, specificity, and accuracy of different diagnostic approaches. Mean MSTT was 6.68 mm in symptomatic patients and 5.61 mm in asymptomatic controls (P<.05). When used as an isolated criterion, MSTT>6.0mm provided best results for accuracy (93.7%) when compared to other measurements of tendon thickness. Also as an isolated criterion, abnormal tendon structure (ATS) yielded 93.2% accuracy for diagnosis. The best overall yield was obtained by both parallel and sequential testing using either MSTT>6.0mm or ATS as diagnostic criteria at no particular order, which provided 99.0% accuracy, 100% sensitivity, and 95.2% specificity. Among these parallel and sequential tests that provided best overall yield, additional analysis revealed that sequential testing first evaluating tendon structure required assessment of 258 criteria (vs. 261 for sequential testing first evaluating tendon thickness and 412 for parallel testing) and demanded a mean of 16.1s to assess diagnostic criteria and reach the diagnosis (vs. 43.3s for sequential testing first evaluating tendon thickness and 47.4s for parallel testing). We found that using either MSTT>6.0mm or ATS as diagnostic criteria for both parallel and sequential testing provides the best overall yield for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. Among these strategies, a two-step sequential approach first assessing tendon structure was advantageous because it required a lower number of criteria to be assessed and demanded less time to assess diagnostic criteria and reach the diagnosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. QUADAS and STARD: evaluating the quality of diagnostic accuracy studies.

    PubMed

    Oliveira, Maria Regina Fernandes de; Gomes, Almério de Castro; Toscano, Cristiana Maria

    2011-04-01

    To compare the performance of two approaches, one based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and another on the Standards for Reporting Studies of Diagnostic Accuracy (STARD), in evaluating the quality of studies validating the OptiMal® rapid malaria diagnostic test. Articles validating the rapid test published until 2007 were searched in the Medline/PubMed database. This search retrieved 13 articles. A combination of 12 QUADAS criteria and three STARD criteria were compared with the 12 QUADAS criteria alone. Articles that fulfilled at least 50% of QUADAS criteria were considered as regular to good quality. Of the 13 articles retrieved, 12 fulfilled at least 50% of QUADAS criteria, and only two fulfilled the STARD/QUADAS criteria combined. Considering the two criteria combination (> 6 QUADAS and > 3 STARD), two studies (15.4%) showed good methodological quality. The articles selection using the proposed combination resulted in two to eight articles, depending on the number of items assumed as cutoff point. The STARD/QUADAS combination has the potential to provide greater rigor when evaluating the quality of studies validating malaria diagnostic tests, given that it incorporates relevant information not contemplated in the QUADAS criteria alone.

  17. Development and Application of a Novel Rasch-Based Methodology for Evaluating Multi-Tiered Assessment Instruments: Validation and Utilization of an Undergraduate Diagnostic Test of the Water Cycle

    ERIC Educational Resources Information Center

    Romine, William L.; Schaffer, Dane L.; Barrow, Lloyd

    2015-01-01

    We describe the development and validation of a three-tiered diagnostic test of the water cycle (DTWC) and use it to evaluate the impact of prior learning experiences on undergraduates' misconceptions. While most approaches to instrument validation take a positivist perspective using singular criteria such as reliability and fit with a measurement…

  18. Systematic Review and Meta-Analysis of Studies Evaluating Diagnostic Test Accuracy: A Practical Review for Clinical Researchers-Part II. Statistical Methods of Meta-Analysis

    PubMed Central

    Lee, Juneyoung; Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies. PMID:26576107

  19. [An evaluation of the effectiveness of laboratory diagnostic methods for brucellosis].

    PubMed

    Gandara, B; Zheludkov, M M; Chernysheva, M I

    1994-01-01

    The diagnostic value of bacteriological and serological methods for the laboratory diagnosis of brucellosis was studied. In the analysis of milk and cheese specimens Brucella cultures were isolated and differentiated as B.melitensis, biovar I, and B.abortus, biovar 4. In 25.6% of cases B.melitensis culture, biovar 1, was isolated from the blood of persons suspected for brucellosis. The isolation of B.melitensis culture from milk showed that this infective agent migrated from small animals to cattle, which was indicative of a high risk of human infection in the state of Zacatecas, Mexico. The comparative evaluation of serological diagnostic methods (the agglutination test in test tubes, Huddleson's slide test, the acidic rose bengal test and the 2-mercaptoethanol test) showed high sensitivity of rapid tests (Huddleson's test and the rose bengal test in 93.7% and 87.9% of cases respectively). The 2-mercaptoethanol test which gave positive results in 63.8% of cases provided additional information characterizing the course of infections process.

  20. Development of a framework for international certification by OIE of diagnostic tests validated as fit for purpose.

    PubMed

    Wright, P; Edwards, S; Diallo, A; Jacobson, R

    2006-01-01

    Historically, the OIE has focused on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants' meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.

  1. Development of a framework for international certification by the OIE of diagnostic tests validated as fit for purpose.

    PubMed

    Wright, P; Edwards, S; Diallo, A; Jacobson, R

    2007-01-01

    Historically, the OIE has focussed on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.

  2. [Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].

    PubMed

    Acevedo González, Juan C; Quintero Oliveros, Silvia

    2015-01-01

    Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  3. Economic evaluation of test-and-treat and empirical treatment strategies in the eradication of Helicobacter pylori infection; A Markov model in an Iranian adult population.

    PubMed

    Mazdaki, Alireza; Ghiasvand, Hesam; Sarabi Asiabar, Ali; Naghdi, Seyran; Aryankhesal, Aidin

    2016-01-01

    Helicobacter pylori may cause many gastrointestinal problems in developing countries such as Iran. We aimed to analyze the cost- effectiveness and cost- utility of the test-and-treat and empirical treatment strategies in managing Helicobacter pylori infection. This was a Markov based economic evaluation. Effectiveness was defined as the symptoms free numbers and QALYs in 100,000 hypothetical adults. The sensitivity analysis was based on Monte Carlo approach. In the test- and- treat strategy, if the serology is the first diagnostic test vs. histology, the cost per symptoms free number would be 291,736.1 Rials while the cost per QALYs would be 339,226.1 Rials. The cost per symptoms free number and cost per QALYs when the 13 C-UBT was used as the first diagnostic test vs. serology was 1,283,200 and 1,492,103 Rials, respectively. In the empirical strategy, if histology is used as the first diagnostic test vs. 13 CUBT, the cost per symptoms free numbers and cost per QALYs would be 793,234 and 955,698 Rials, respectively. If serology were used as the first diagnostic test vs. histology, the cost per symptoms free and QALYs would be 793,234 and 368941 Rials, respectively. There was no significant and considerable dominancy between the alternatives and the diagnostic tests.

  4. Estimation of diagnostic test accuracy without full verification: a review of latent class methods

    PubMed Central

    Collins, John; Huynh, Minh

    2014-01-01

    The performance of a diagnostic test is best evaluated against a reference test that is without error. For many diseases, this is not possible, and an imperfect reference test must be used. However, diagnostic accuracy estimates may be biased if inaccurately verified status is used as the truth. Statistical models have been developed to handle this situation by treating disease as a latent variable. In this paper, we conduct a systematized review of statistical methods using latent class models for estimating test accuracy and disease prevalence in the absence of complete verification. PMID:24910172

  5. Diagnostic accuracy of physical examination for anterior knee instability: a systematic review.

    PubMed

    Leblanc, Marie-Claude; Kowalczuk, Marcin; Andruszkiewicz, Nicole; Simunovic, Nicole; Farrokhyar, Forough; Turnbull, Travis Lee; Debski, Richard E; Ayeni, Olufemi R

    2015-10-01

    Determining diagnostic accuracy of Lachman, pivot shift and anterior drawer tests versus gold standard diagnosis (magnetic resonance imaging or arthroscopy) for anterior cruciate ligament (ACL) insufficiency cases. Secondarily, evaluating effects of: chronicity, partial rupture, awake versus anaesthetized evaluation. Searching MEDLINE, EMBASE and PubMed identified studies on diagnostic accuracy for ACL insufficiency. Studies identification and data extraction were performed in duplicate. Quality assessment used QUADAS tool, and statistical analyses were completed for pooled sensitivity and specificity. Eight studies were included. Given insufficient data, pooled analysis was only possible for sensitivity on Lachman and pivot shift test. During awake evaluation, sensitivity for the Lachman test was 89 % (95 % CI 0.76, 0.98) for all rupture types, 96 % (95 % CI 0.90, 1.00) for complete ruptures and 68 % (95 % CI 0.25, 0.98) for partial ruptures. For pivot shift in awake evaluation, results were 79 % (95 % CI 0.63, 0.91) for all rupture types, 86 % (95 % CI 0.68, 0.99) for complete ruptures and 67 % (95 % CI 0.47, 0.83) for partial ruptures. Decreased sensitivity of Lachman and pivot shift tests for partial rupture cases and for awake patients raised suspicions regarding the accuracy of these tests for diagnosis of ACL insufficiency. This may lead to further research aiming to improve the understanding of the true accuracy of these physical diagnostic tests and increase the reliability of clinical investigation for this pathology. IV.

  6. Difference of Diagnostic Rates and Analytical Methods in the Test Positions of Vestibular Evoked Myogenic Potentials

    PubMed Central

    Park, Jeong Mee; Yong, Sang Yeol; Kim, Jong Heon; Kim, Hee; Park, Sang-Yoo

    2014-01-01

    Objective To compare the differences of diagnostic rates, of the two widely used test positions, in measuring vestibular evoked myogenic potentials (VEMP) and selecting the most appropriate analytical method for diagnostic criteria for the patients with vertigo. Methods Thirty-two patients with vertigo were tested in two comparative testing positions: turning the head to the opposite side of the evaluating side and bowing while in seated position, and bowing while in supine positions. Abnormalities were determined by prolonged latency of p13 or n23, shortening of the interpeak latency, and absence of VEMP formation. Results Using the three criteria above for determining abnormalities, both the seated and supine positions showed no significant differences in diagnostic rates, however, the concordance correlation of the two positions was low. When using only the prolonged latency of p13 or n23 in the two positions, diagnostic rates were not significantly different and their concordance correlation was high. On the other hand, using only the shortened interpeak latency in both positions showed no significant difference of diagnostic rates, and the degree of agreement between two positions was low. Conclusion Bowing while in seated position with the head turned in the opposite direction to the area being evaluated is found to be the best VEMP test position due to the consistent level of sternocleidomastoid muscle tension and the high level of compliance. Also, among other diagnostic analysis methods, using prolonged latency of p13 or n23 as the criterion is found to be the most appropriate method of analysis for the VEMP test. PMID:24855617

  7. Disparities in the diagnostic process of Duchenne and Becker muscular dystrophy.

    PubMed

    Holtzer, Caleb; Meaney, F John; Andrews, Jennifer; Ciafaloni, Emma; Fox, Deborah J; James, Katherine A; Lu, Zhenqiang; Miller, Lisa; Pandya, Shree; Ouyang, Lijing; Cunniff, Christopher

    2011-11-01

    To determine whether sociodemographic factors are associated with delays at specific steps in the diagnostic process of Duchenne and Becker muscular dystrophy. We examined abstracted medical records for 540 males from population-based surveillance sites in Arizona, Colorado, Georgia, Iowa, and western New York. We used linear regressions to model the association of three sociodemographic characteristics with age at initial medical evaluation, first creatine kinase measurement, and earliest DNA analysis while controlling for changes in the diagnostic process over time. The analytical dataset included 375 males with information on family history of Duchenne and Becker muscular dystrophy, neighborhood poverty levels, and race/ethnicity. Black and Hispanic race/ethnicity predicted older ages at initial evaluation, creatine kinase measurement, and DNA testing (P < 0.05). A positive family history of Duchenne and Becker muscular dystrophy predicted younger ages at initial evaluation, creatine kinase measurement and DNA testing (P < 0.001). Higher neighborhood poverty was associated with earlier ages of evaluation (P < 0.05). Racial and ethnic disparities in the diagnostic process for Duchenne and Becker muscular dystrophy are evident even after adjustment for family history of Duchenne and Becker muscular dystrophy and changes in the diagnostic process over time. Black and Hispanic children are initially evaluated at older ages than white children, and the gap widens at later steps in the diagnostic process.

  8. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    PubMed

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  9. Laparoscopic management and its outcomes in cases with nonpalpable testis.

    PubMed

    Erdoğan, Cankat; Bahadır, Berktuğ; Taşkınlar, Hakan; Naycı, Ali

    2017-06-01

    Diagnostic laparoscopy is the gold standard in the algorithm of nonpalpable testis. Testicular tissue is examined and treatment is planned accordingly. In this study we reviewed the place of diagnostic laparoscopy, and evaluated the results and effectiveness of laparoscopy in the diagnosis and management of nonpalpable testis. Children who had diagnostic laparoscopy for nonpalpable testes were included in the study. Physical examination results, ultrasonography (USG) reports, age at surgery, laparoscopic and inguinal exploration findings, surgical procedures, orchiopexy results, early and late-term complications were evaluated. Follow-up visits were performed at 3-month intervals for the first, at 6-month intervals for the 2. year, then at yearly intervals. Testicular size and location was evaluated by during control examination. Overall 58 boys, and 68 testes (26 left: 44.8%; 22 right: 37.9%, and 10 bilateral: 17.2%) were included in the study. Mean age at surgery was 5.5 years (10 months-17 years). Diagnostic value of USG was 15.7%. Diagnostic laparoscopy findings were as follows: Group 1: blind-ended vessels, n=7 (10.2%); Group 2: intraabdominal testes, n=8 (11.7%); Group 3: vas and vessels entering internal ring, n=53 (77.9%). Overall 43 testes underwent orchiopexy, which were normal (n=8) or hypoplastic (n=35). Mean follow-up period was 19 months (1-12 years), and on an average 7 visits were performed (5-14). On follow-up, 5 testes were normal-sized and located in the scrotum, while 4 testes were atrophic and underwent orchiectomy. Two testes were found in the inguinal canal and redo orchiopexy was performed. Control USG revealed reduced testicular blood supply and volume. Laparoscopic surgery is safe and effective in the management of nonpalpable testes. In the majority, routine use of diagnostic laparoscopy in the algorithma does not confer any additional contributions in many patients.

  10. Validity Arguments for Diagnostic Assessment Using Automated Writing Evaluation

    ERIC Educational Resources Information Center

    Chapelle, Carol A.; Cotos, Elena; Lee, Jooyoung

    2015-01-01

    Two examples demonstrate an argument-based approach to validation of diagnostic assessment using automated writing evaluation (AWE). "Criterion"®, was developed by Educational Testing Service to analyze students' papers grammatically, providing sentence-level error feedback. An interpretive argument was developed for its use as part of…

  11. 20 CFR 416.919m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AGED, BLIND, AND DISABLED Determining Disability and Blindness Standards for the Type of Referral and for Report Content § 416.919m Diagnostic tests or procedures. We will request the results of any..., arteriograms, or cardiac catheterizations for the evaluation of disability under the Supplemental Security...

  12. The diagnostic plot analysis of artesian aquifers with case studies in Table Mountain Group of South Africa

    NASA Astrophysics Data System (ADS)

    Sun, Xiaobin; Xu, Yongxin; Lin, Lixiang

    2015-05-01

    Parameter estimates of artesian aquifers where piezometric head is above ground level are largely made through free-flowing and recovery tests. The straight-line method proposed by Jacob-Lohman is often used for interpretation of flow rate measured at flowing artesian boreholes. However, the approach fails to interpret the free-flowing test data from two artesian boreholes in the fractured-rock aquifer in Table Mountain Group (TMG) of South Africa. The diagnostic plot method using the reciprocal rate derivative is adapted to evaluate the artesian aquifer properties. The variation of the derivative helps not only identify flow regimes and discern the boundary conditions, but also facilitates conceptualization of the aquifer system and selection of an appropriate model for data interpretation later on. Test data from two free-flowing tests conducted in different sites in TMG are analysed using the diagnostic plot method. Based on the results, conceptual models and appropriate approaches are developed to evaluate the aquifer properties. The advantages and limitations of using the diagnostic plot method on free-flowing test data are discussed.

  13. Evaluation of Raman spectroscopy in comparison to commonly performed dengue diagnostic tests

    NASA Astrophysics Data System (ADS)

    Khan, Saranjam; Ullah, Rahat; Khurram, Muhammad; Ali, Hina; Mahmood, Arshad; Khan, Ajmal; Ahmed, Mushtaq

    2016-09-01

    This study demonstrates the evaluation of Raman spectroscopy as a rapid diagnostic test in comparison to commonly performed tests for an accurate detection of dengue fever in human blood sera. Blood samples of 104 suspected dengue patients collected from Holy Family Hospital, Rawalpindi, Pakistan, have been used in this study. Out of 104 samples, 52 (50%) were positive based on immunoglobulin G (IgG), whereas 54 (52%) were positive based on immunoglobulin M (IgM) antibody tests. For the determination of the diagnostic capabilities of Raman spectroscopy, accuracy, sensitivity, specificity and false positive rate have been calculated in comparison to normally performed IgM and IgG captured enzyme-linked immunosorbent assay tests. Accuracy, precision, specificity, and sensitivity for Raman spectroscopy in comparison to IgM were found to be 66%, 70%, 72%, and 61%, whereas based on IgG they were 47%, 46%, 52%, and 43%, respectively.

  14. Image processing and machine learning for fully automated probabilistic evaluation of medical images.

    PubMed

    Sajn, Luka; Kukar, Matjaž

    2011-12-01

    The paper presents results of our long-term study on using image processing and data mining methods in a medical imaging. Since evaluation of modern medical images is becoming increasingly complex, advanced analytical and decision support tools are involved in integration of partial diagnostic results. Such partial results, frequently obtained from tests with substantial imperfections, are integrated into ultimate diagnostic conclusion about the probability of disease for a given patient. We study various topics such as improving the predictive power of clinical tests by utilizing pre-test and post-test probabilities, texture representation, multi-resolution feature extraction, feature construction and data mining algorithms that significantly outperform medical practice. Our long-term study reveals three significant milestones. The first improvement was achieved by significantly increasing post-test diagnostic probabilities with respect to expert physicians. The second, even more significant improvement utilizes multi-resolution image parametrization. Machine learning methods in conjunction with the feature subset selection on these parameters significantly improve diagnostic performance. However, further feature construction with the principle component analysis on these features elevates results to an even higher accuracy level that represents the third milestone. With the proposed approach clinical results are significantly improved throughout the study. The most significant result of our study is improvement in the diagnostic power of the whole diagnostic process. Our compound approach aids, but does not replace, the physician's judgment and may assist in decisions on cost effectiveness of tests. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  15. Electrophysiology of Cranial Nerve Testing: Trigeminal and Facial Nerves.

    PubMed

    Muzyka, Iryna M; Estephan, Bachir

    2018-01-01

    The clinical examination of the trigeminal and facial nerves provides significant diagnostic value, especially in the localization of lesions in disorders affecting the central and/or peripheral nervous system. The electrodiagnostic evaluation of these nerves and their pathways adds further accuracy and reliability to the diagnostic investigation and the localization process, especially when different testing methods are combined based on the clinical presentation and the electrophysiological findings. The diagnostic uniqueness of the trigeminal and facial nerves is their connectivity and their coparticipation in reflexes commonly used in clinical practice, namely the blink and corneal reflexes. The other reflexes used in the diagnostic process and lesion localization are very nerve specific and add more diagnostic yield to the workup of certain disorders of the nervous system. This article provides a review of commonly used electrodiagnostic studies and techniques in the evaluation and lesion localization of cranial nerves V and VII.

  16. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    PubMed

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most effective test in MCI detection, especially for the population with symptoms of memory deterioration. They can be potentially used as the triage screening test for MCI in primary care setting. But when a patient shows cognitive impairments beyond memory deterioration, a more comprehensive test such as the MoCA should be used. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  17. Diagnostic laryngeal electromyography: The Wake Forest experience 1995-1999.

    PubMed

    Koufman, J A; Postma, G N; Whang, C S; Rees, C J; Amin, M R; Belafsky, P C; Johnson, P E; Connolly, K M; Walker, F O

    2001-06-01

    Laryngeal electromyography (LEMG) is a valuable diagnostic/prognostic test for patients with suspected laryngeal neuromuscular disorders. To report our experience with diagnostic LEMG at the Center for Voice Disorders of Wake Forest University and to evaluate the impact of LEMG on clinical management. Retrospective chart review of 415 patients who underwent diagnostic LEMG over a 5-year period (1995-1999). Of 415 studies, 83% (346 of 415) were abnormal, indicating a neuropathic process. LEMG results altered the diagnostic evaluation (eg, the type of radiographic imaging) in 11% (46 of 415) of the patients. Unexpected LEMG findings (eg, contralateral neuropathy) were found in 26% (107 of 415) of the patients, and LEMG results differentiated vocal fold paralysis from fixation in 12% (49 of 415). Finally, LEMG results altered the clinical management (eg, changed the timing and/or type of surgical procedure) in 40% (166 of 415) of the patients. LEMG is a valuable diagnostic test that aids the clinician in the diagnosis and management of laryngeal neuromuscular disorders.

  18. Outbreak!: Teaching Clinical and Diagnostic Microbiology Methodologies with an Interactive Online Game

    ERIC Educational Resources Information Center

    Clark, Sherri; Smith, Geoffrey Battle

    2004-01-01

    Outbreak! is an online, interactive educational game that helps students and teachers learn and evaluate clinical microbiology skills. When the game was used in introductory microbiology laboratories, qualitative evaluation by students showed very positive responses and increased learning. Outbreak! allows students to design diagnostic tests and…

  19. The diagnostic performance of coronary artery angiography with 64-MSCT and post 64-MSCT: systematic review and meta-analysis.

    PubMed

    Li, Min; Du, Xiang-Min; Jin, Zhi-Tao; Peng, Zhao-Hui; Ding, Juan; Li, Li

    2014-01-01

    To comprehensively investigate the diagnostic performance of coronary artery angiography with 64-MDCT and post 64-MDCT. PubMed was searched for all published studies that evaluated coronary arteries with 64-MDCT and post 64-MDCT. The clinical diagnostic role was evaluated by applying the likelihood ratios (LRs) to calculate the post-test probability based on Bayes' theorem. 91 studies that met our inclusion criteria were ultimately included in the analysis. The pooled positive and negative LRs at patient level were 8.91 (95% CI, 7.53, 10.54) and 0.02 (CI, 0.01, 0.03), respectively. For studies that did not claim that non-evaluable segments were included, the pooled positive and negative LRs were 11.16 (CI, 8.90, 14.00) and 0.01 (CI, 0.01, 0.03), respectively. For studies including uninterruptable results, the diagnostic performance decreased, with the pooled positive LR 7.40 (CI, 6.00, 9.13) and negative LR 0.02 (CI, 0.01, 0.03). The areas under the summary ROC curve were 0.98 (CI, 0.97 to 0.99) for 64-MDCT and 0.96 (CI, 0.94 to 0.98) for post 64-MDCT, respectively. For references explicitly stating that the non-assessable segments were included during analysis, a post-test probability of negative results >95% and a positive post-test probability <95% could be obtained for patients with a pre-test probability of <73% for coronary artery disease (CAD). On the other hand, when the pre-test probability of CAD was >73%, the diagnostic role was reversed, with a positive post-test probability of CAD >95% and a negative post-test probability of CAD <95%. The diagnostic performance of post 64-MDCT does not increase as compared with 64-MDCT. CTA, overall, is a test of exclusion for patients with a pre-test probability of CAD<73%, while for patients with a pre-test probability of CAD>73%, CTA is a test used to confirm the presence of CAD.

  20. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel ‘V-plot’ methodology to display accuracy values

    PubMed Central

    Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424

  1. Diagnostic efficacy of microscopy, rapid diagnostic test and polymerase chain reaction for malaria using bayesian latent class analysis.

    PubMed

    Saha, Sreemanti; Narang, Rahul; Deshmukh, Pradeep; Pote, Kiran; Anvikar, Anup; Narang, Pratibha

    2017-01-01

    The diagnostic techniques for malaria are undergoing a change depending on the availability of newer diagnostics and annual parasite index of infection in a particular area. At the country level, guidelines are available for selection of diagnostic tests; however, at the local level, this decision is made based on malaria situation in the area. The tests are evaluated against the gold standard, and if that standard has limitations, it becomes difficult to compare other available tests. Bayesian latent class analysis computes its internal standard rather than using the conventional gold standard and helps comparison of various tests including the conventional gold standard. In a cross-sectional study conducted in a tertiary care hospital setting, we have evaluated smear microscopy, rapid diagnostic test (RDT), and polymerase chain reaction (PCR) for diagnosis of malaria using Bayesian latent class analysis. We found the magnitude of malaria to be 17.7% (95% confidence interval: 12.5%-23.9%) among the study subjects. In the present study, the sensitivity of microscopy was 63%, but it had very high specificity (99.4%). Sensitivity and specificity of RDT and PCR were high with RDT having a marginally higher sensitivity (94% vs. 90%) and specificity (99% vs. 95%). On comparison of likelihood ratios (LRs), RDT had the highest LR for positive test result (175) and the lowest LR for negative test result (0.058) among the three tests. In settings like ours conventional smear microscopy may be replaced with RDT and as we move toward elimination and facilities become available PCR may be roped into detect cases with lower parasitaemia.

  2. Evaluating College Students' Conceptual Knowledge of Modern Physics: Test of Understanding on Concepts of Modern Physics (TUCO-MP)

    ERIC Educational Resources Information Center

    Akarsu, Bayram

    2011-01-01

    In present paper, we propose a new diagnostic test to measure students' conceptual knowledge of principles of modern physics topics. Over few decades since born of physics education research (PER), many diagnostic instruments that measure students' conceptual understanding of various topics in physics, the earliest tests developed in PER are Force…

  3. Diagnostic Accuracy of Chinese Medicine Diagnosis Scale of Phlegm and Blood Stasis Syndrome in Coronary Heart Disease: A Study Protocol.

    PubMed

    Liu, Xiao-Qi; Peng, Dan-Hong; Wang, Yan-Ping; Xie, Rong; Chen, Xin-Lin; Yu, Chun-Quan; Li, Xian-Tao

    2018-05-03

    Phlegm and blood stasis syndrome (PBSS) is one of the main syndromes in coronary heart disease (CHD). Syndromes of Chinese medicine (CM) are lack of quantitative and easyimplementation diagnosis standards. To quantify and standardize the diagnosis of PBSS, scales are usually applied. To evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. Six hundred patients with stable angina pectoris of CHD, 300 in case group and 300 in control group, will be recruited from 5 hospitals across China. Diagnosis from 2 experts will be considered as the "gold standard". The study design consists of 2 phases: pilot test is used to evaluate the reliability and validity, and diagnostic test is used to assess the diagnostic accuracy of the scale, including sensitivity, specififi city, likelihood ratio and area under the receiver operator characteristic (ROC) curve. This study will evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. The consensus of 2 experts may not be ideal as a "gold standard", and itself still requires further study. (No. ChiCTR-OOC-15006599).

  4. bcROCsurface: an R package for correcting verification bias in estimation of the ROC surface and its volume for continuous diagnostic tests.

    PubMed

    To Duc, Khanh

    2017-11-18

    Receiver operating characteristic (ROC) surface analysis is usually employed to assess the accuracy of a medical diagnostic test when there are three ordered disease status (e.g. non-diseased, intermediate, diseased). In practice, verification bias can occur due to missingness of the true disease status and can lead to a distorted conclusion on diagnostic accuracy. In such situations, bias-corrected inference tools are required. This paper introduce an R package, named bcROCsurface, which provides utility functions for verification bias-corrected ROC surface analysis. The shiny web application of the correction for verification bias in estimation of the ROC surface analysis is also developed. bcROCsurface may become an important tool for the statistical evaluation of three-class diagnostic markers in presence of verification bias. The R package, readme and example data are available on CRAN. The web interface enables users less familiar with R to evaluate the accuracy of diagnostic tests, and can be found at http://khanhtoduc.shinyapps.io/bcROCsurface_shiny/ .

  5. Accuracy of clinical tests in the diagnosis of anterior cruciate ligament injury: a systematic review

    PubMed Central

    2014-01-01

    Background Numerous clinical tests are used in the diagnosis of anterior cruciate ligament (ACL) injury but their accuracy is unclear. The purpose of this study is to evaluate the diagnostic accuracy of clinical tests for the diagnosis of ACL injury. Methods Study Design: Systematic review. The review protocol was registered through PROSPERO (CRD42012002069). Electronic databases (PubMed, MEDLINE, EMBASE, CINAHL) were searched up to 19th of June 2013 to identify diagnostic studies comparing the accuracy of clinical tests for ACL injury to an acceptable reference standard (arthroscopy, arthrotomy, or MRI). Risk of bias was appraised using the QUADAS-2 checklist. Index test accuracy was evaluated using a descriptive analysis of paired likelihood ratios and displayed as forest plots. Results A total of 285 full-text articles were assessed for eligibility, from which 14 studies were included in this review. Included studies were deemed to be clinically and statistically heterogeneous, so a meta-analysis was not performed. Nine clinical tests from the history (popping sound at time of injury, giving way, effusion, pain, ability to continue activity) and four from physical examination (anterior draw test, Lachman’s test, prone Lachman’s test and pivot shift test) were investigated for diagnostic accuracy. Inspection of positive and negative likelihood ratios indicated that none of the individual tests provide useful diagnostic information in a clinical setting. Most studies were at risk of bias and reported imprecise estimates of diagnostic accuracy. Conclusion Despite being widely used and accepted in clinical practice, the results of individual history items or physical tests do not meaningfully change the probability of ACL injury. In contrast combinations of tests have higher diagnostic accuracy; however the most accurate combination of clinical tests remains an area for future research. Clinical relevance Clinicians should be aware of the limitations associated with the use of clinical tests for diagnosis of ACL injury. PMID:25187877

  6. Accuracy of clinical tests in the diagnosis of anterior cruciate ligament injury: a systematic review.

    PubMed

    Swain, Michael S; Henschke, Nicholas; Kamper, Steven J; Downie, Aron S; Koes, Bart W; Maher, Chris G

    2014-01-01

    Numerous clinical tests are used in the diagnosis of anterior cruciate ligament (ACL) injury but their accuracy is unclear. The purpose of this study is to evaluate the diagnostic accuracy of clinical tests for the diagnosis of ACL injury. Systematic review. The review protocol was registered through PROSPERO (CRD42012002069). Electronic databases (PubMed, MEDLINE, EMBASE, CINAHL) were searched up to 19th of June 2013 to identify diagnostic studies comparing the accuracy of clinical tests for ACL injury to an acceptable reference standard (arthroscopy, arthrotomy, or MRI). Risk of bias was appraised using the QUADAS-2 checklist. Index test accuracy was evaluated using a descriptive analysis of paired likelihood ratios and displayed as forest plots. A total of 285 full-text articles were assessed for eligibility, from which 14 studies were included in this review. Included studies were deemed to be clinically and statistically heterogeneous, so a meta-analysis was not performed. Nine clinical tests from the history (popping sound at time of injury, giving way, effusion, pain, ability to continue activity) and four from physical examination (anterior draw test, Lachman's test, prone Lachman's test and pivot shift test) were investigated for diagnostic accuracy. Inspection of positive and negative likelihood ratios indicated that none of the individual tests provide useful diagnostic information in a clinical setting. Most studies were at risk of bias and reported imprecise estimates of diagnostic accuracy. Despite being widely used and accepted in clinical practice, the results of individual history items or physical tests do not meaningfully change the probability of ACL injury. In contrast combinations of tests have higher diagnostic accuracy; however the most accurate combination of clinical tests remains an area for future research. Clinicians should be aware of the limitations associated with the use of clinical tests for diagnosis of ACL injury.

  7. Objective speech quality evaluation of real-time speech coders

    NASA Astrophysics Data System (ADS)

    Viswanathan, V. R.; Russell, W. H.; Huggins, A. W. F.

    1984-02-01

    This report describes the work performed in two areas: subjective testing of a real-time 16 kbit/s adaptive predictive coder (APC) and objective speech quality evaluation of real-time coders. The speech intelligibility of the APC coder was tested using the Diagnostic Rhyme Test (DRT), and the speech quality was tested using the Diagnostic Acceptability Measure (DAM) test, under eight operating conditions involving channel error, acoustic background noise, and tandem link with two other coders. The test results showed that the DRT and DAM scores of the APC coder equalled or exceeded the corresponding test scores fo the 32 kbit/s CVSD coder. In the area of objective speech quality evaluation, the report describes the development, testing, and validation of a procedure for automatically computing several objective speech quality measures, given only the tape-recordings of the input speech and the corresponding output speech of a real-time speech coder.

  8. Built-In-Test Equipment Requirements Workshop. Workshop Presentation

    DTIC Science & Technology

    1981-08-01

    quantitatively evaluated in test. (2) It is necessary to develop the statistical methods that should be used for predicting and confirming of diagnostic...of different performance levels of BIT peacetime and wartime applications, and the corresponding manpower and other support requirements should be...reports. The scope of the workshop involves the areas of require- ments for built-in-test and diagnostics, and the methods of testing to ensure that the

  9. Portable Health Algorithms Test System

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Wong, Edmond; Fulton, Christopher E.; Sowers, Thomas S.; Maul, William A.

    2010-01-01

    A document discusses the Portable Health Algorithms Test (PHALT) System, which has been designed as a means for evolving the maturity and credibility of algorithms developed to assess the health of aerospace systems. Comprising an integrated hardware-software environment, the PHALT system allows systems health management algorithms to be developed in a graphical programming environment, to be tested and refined using system simulation or test data playback, and to be evaluated in a real-time hardware-in-the-loop mode with a live test article. The integrated hardware and software development environment provides a seamless transition from algorithm development to real-time implementation. The portability of the hardware makes it quick and easy to transport between test facilities. This hard ware/software architecture is flexible enough to support a variety of diagnostic applications and test hardware, and the GUI-based rapid prototyping capability is sufficient to support development execution, and testing of custom diagnostic algorithms. The PHALT operating system supports execution of diagnostic algorithms under real-time constraints. PHALT can perform real-time capture and playback of test rig data with the ability to augment/ modify the data stream (e.g. inject simulated faults). It performs algorithm testing using a variety of data input sources, including real-time data acquisition, test data playback, and system simulations, and also provides system feedback to evaluate closed-loop diagnostic response and mitigation control.

  10. Diagnostic triage and the role of natriuretic peptide testing and echocardiography for suspected heart failure: an appropriateness ratings evaluation by UK GPs

    PubMed Central

    Campbell, Stephen M; Fuat, Ahmet; Summerton, Nick; Lancaster, Neil; Hobbs, FD Richard

    2011-01-01

    Background Some UK GPs are acquiring access to natriuretic peptide (NP) testing or echocardiography as diagnostic tests for heart failure. This study developed appropriateness ratings for the diagnostic application of these tests in routine general practice. Aim To develop appropriateness ratings for the diagnostic application of NP testing or echocardiography for heart failure in general practice. Design and setting An appropriateness ratings evaluation in UK general practice. Method Four presenting symptoms (cough, bilateral ankle swelling, dyspnoea, fatigue), three levels of risk of cardiovascular disease (low, intermediate, high), and dichotomous categorisations of cardiovascular/chest examination and electrocardiogram result, were used to create 540 appropriateness scenarios for patients in whom NP testing or echocardiography might be considered. These were rated by a 10-person expert panel, consisting of GPs and GPs with specialist interests in cardiology, in a two-round RAND Appropriateness Method. Results Onward referral for NP testing or echocardiography was rated as an appropriate next step in 217 (40.2%) of the 540 scenarios; in 194 (35.9%) it was rated inappropriate. The ratings also show where NP testing or echocardiography were ranked as equivalent next steps and when one test was seen as the more appropriate than the other. Conclusion NP testing should be the routine test for suspected heart failure where referral for diagnostic testing is considered appropriate. An abnormal electrocardiogram status makes referral to echocardiography an accompanying, or more appropriate, next step alongside NP testing, especially in the presence of dyspnoea. Abnormal NP testing should subsequently be followed up with referral for echocardiography. PMID:21722451

  11. How to: evaluate a diagnostic test.

    PubMed

    Leeflang, Mariska M G; Allerberger, Franz

    2018-06-12

    The development of an in vitro diagnostic test from a good idea to a clinically relevant tool takes several steps, with more stringent requirements at every step. This article aims to summarize the necessary questions to be asked about a test and to illustrate study designs answering these questions. We also aim to relate the Regulation (EU) 2017/746 to the needs of evidence-based diagnostic testing, where applicable. We used literature on evidence-based diagnostics, a text book on clinical trials in the development and marketing of medical devices and the English version of Regulation 2017/746 of the European Parliament and of the Council on in vitro diagnostic medical devices. The combination of different test uses and different stages of development determine the required test characteristics and suitability of study designs. In an earlier stage of test development it may be crucial to know whether a test can differentiate diseased persons from healthy controls, while this tells us little about how a test will perform in practice. Later stages focus on the diagnostic accuracy of a test in a clinically relevant situation. However, a test that perfectly distinguishes between patients with and without a certain condition may still have little effect on patient outcomes. Therefore, randomized controlled trials of testing may be needed, as well as post-marketing monitoring. Both researchers and users of tests need to be aware of the limitations of diagnostic test accuracy and realize that accuracy is only indirectly linked to people's health status. Copyright © 2018. Published by Elsevier Ltd.

  12. TOCUSO: Test of Conceptual Understanding on High School Optics Topics

    ERIC Educational Resources Information Center

    Akarsu, Bayram

    2012-01-01

    Physics educators around the world often need reliable diagnostic materials to measure students' understanding of physics concept in high school. The purpose of this study is to evaluate a new diagnostic tool on High School Optics concept. Test of Conceptual Understanding on High School Optics (TOCUSO) consists of 25 conceptual items that measures…

  13. INNOVATIVE TECHNOLOGY VERIFICATION REPORT "FIELD MEASUREMENT TECHNOLOGIES FOR TOTAL PETROLEUM HYDROCARBONS IN SOIL" STRATEGIC DIAGNOSTICS INC. ENSYS PETRO TEST SYSTEM

    EPA Science Inventory



    The EnSys Petro Test System developed by Strategic Diagnostics Inc. (SDI), was demonstrated under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in June 2000 at the Navy Base Ventura County site in Port Hueneme, California. The...

  14. A manifesto for cardiovascular imaging: addressing the human factor†

    PubMed Central

    Fraser, Alan G

    2017-01-01

    Abstract Our use of modern cardiovascular imaging tools has not kept pace with their technological development. Diagnostic errors are common but seldom investigated systematically. Rather than more impressive pictures, our main goal should be more precise tests of function which we select because their appropriate use has therapeutic implications which in turn have a beneficial impact on morbidity or mortality. We should practise analytical thinking, use checklists to avoid diagnostic pitfalls, and apply strategies that will reduce biases and avoid overdiagnosis. We should develop normative databases, so that we can apply diagnostic algorithms that take account of variations with age and risk factors and that allow us to calculate pre-test probability and report the post-test probability of disease. We should report the imprecision of a test, or its confidence limits, so that reference change values can be considered in daily clinical practice. We should develop decision support tools to improve the quality and interpretation of diagnostic imaging, so that we choose the single best test irrespective of modality. New imaging tools should be evaluated rigorously, so that their diagnostic performance is established before they are widely disseminated; this should be a shared responsibility of manufacturers with clinicians, leading to cost-effective implementation. Trials should evaluate diagnostic strategies against independent reference criteria. We should exploit advances in machine learning to analyse digital data sets and identify those features that best predict prognosis or responses to treatment. Addressing these human factors will reap benefit for patients, while technological advances continue unpredictably. PMID:29029029

  15. A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

    NASA Astrophysics Data System (ADS)

    Nam, Kyoung Won; Kim, In Young; Kang, Ho Chul; Yang, Hee Kyung; Yoon, Chang Ki; Hwang, Jeong Min; Kim, Young Jae; Kim, Tae Yun; Kim, Kwang Gi

    2012-10-01

    Accurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 < 0.05), but no statistically significant difference between the proposed method and the Krimsky test (p = 0.912 > 0.05). The measurements of the two methods were highly correlated (r = 0.969, p < 0.05). From the experimental results, we believe that the proposed diagnostic method has the potential to be a diagnostic tool that measures the physical disorder of the human eye to diagnose non-invasively the severity of strabismus.

  16. Evaluation of the accuracy of the EasyTest™ malaria Pf/Pan Ag, a rapid diagnostic test, in Uganda.

    PubMed

    Chong, Chom-Kyu; Cho, Pyo Yun; Na, Byoung-Kuk; Ahn, Seong Kyu; Kim, Jin Su; Lee, Jin-Soo; Lee, Sung-Keun; Han, Eun-Taek; Kim, Hak-Yong; Park, Yun-Kyu; Cha, Seok Ho; Kim, Tong-Soo

    2014-10-01

    In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest™ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ≤500 parasites/µl, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ≥100 parasites/µl. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan EasyTest™ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda.

  17. Evaluation of the Accuracy of the EasyTest™ Malaria Pf/Pan Ag, a Rapid Diagnostic Test, in Uganda

    PubMed Central

    Chong, Chom-Kyu; Cho, Pyo Yun; Na, Byoung-Kuk; Ahn, Seong Kyu; Kim, Jin Su; Lee, Jin-Soo; Lee, Sung-Keun; Han, Eun-Taek; Kim, Hak-Yong; Park, Yun-Kyu; Cha, Seok Ho

    2014-01-01

    In recent years, rapid diagnostic tests (RDTs) have been widely used for malaria detection, primarily because of their simple operation, fast results, and straightforward interpretation. The Asan EasyTest™ Malaria Pf/Pan Ag is one of the most commonly used malaria RDTs in several countries, including Korea and India. In this study, we tested the diagnostic performance of this RDT in Uganda to evaluate its usefulness for field diagnosis of malaria in this country. Microscopic and PCR analyses, and the Asan EasyTest™ Malaria Pf/Pan Ag rapid diagnostic test, were performed on blood samples from 185 individuals with suspected malaria in several villages in Uganda. Compared to the microscopic analysis, the sensitivity of the RDT to detect malaria infection was 95.8% and 83.3% for Plasmodium falciparum and non-P. falciparum, respectively. Although the diagnostic sensitivity of the RDT decreased when parasitemia was ≤500 parasites/µl, it showed 96.8% sensitivity (98.4% for P. falciparum and 93.8% for non-P. falciparum) in blood samples with parasitemia ≥100 parasites/µl. The specificity of the RDT was 97.3% for P. falciparum and 97.3% for non-P. falciparum. These results collectively suggest that the accuracy of the Asan EasyTest™ Malaria Pf/Pan Ag makes it an effective point-of-care diagnostic tool for malaria in Uganda. PMID:25352698

  18. Genetic Evaluation of Short Stature

    PubMed Central

    Rosenfeld, Ron G.

    2014-01-01

    Context: Genetics plays a major role in determining an individual's height. Although there are many monogenic disorders that lead to perturbations in growth and result in short stature, there is still no consensus as to the role that genetic diagnostics should play in the evaluation of a child with short stature. Evidence Acquisition: A search of PubMed was performed, focusing on the genetic diagnosis of short stature as well as on specific diagnostic subgroups included in this article. Consensus guidelines were reviewed. Evidence Synthesis: There are a multitude of rare genetic causes of severe short stature. There is no high-quality evidence to define the optimal approach to the genetic evaluation of short stature. We review genetic etiologies of a number of diagnostic subgroups and propose an algorithm for genetic testing based on these subgroups. Conclusion: Advances in genomic technologies are revolutionizing the diagnostic approach to short stature. Endocrinologists must become facile with the use of genetic testing in order to identify the various monogenic disorders that present with short stature. PMID:24915122

  19. 40 CFR 60.53b - Standards for municipal waste combustor operating practices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... for the purpose of evaluating system performance, testing new technology or control technologies... evaluating system performance, testing new technology or control technologies, diagnostic testing, or related... (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of...

  20. Higher cost of implementing Xpert(®) MTB/RIF in Ugandan peripheral settings: implications for cost-effectiveness.

    PubMed

    Hsiang, E; Little, K M; Haguma, P; Hanrahan, C F; Katamba, A; Cattamanchi, A; Davis, J L; Vassall, A; Dowdy, D

    2016-09-01

    Initial cost-effectiveness evaluations of Xpert(®) MTB/RIF for tuberculosis (TB) diagnosis have not fully accounted for the realities of implementation in peripheral settings. To evaluate costs and diagnostic outcomes of Xpert testing implemented at various health care levels in Uganda. We collected empirical cost data from five health centers utilizing Xpert for TB diagnosis, using an ingredients approach. We reviewed laboratory and patient records to assess outcomes at these sites and10 sites without Xpert. We also estimated incremental cost-effectiveness of Xpert testing; our primary outcome was the incremental cost of Xpert testing per newly detected TB case. The mean unit cost of an Xpert test was US$21 based on a mean monthly volume of 54 tests per site, although unit cost varied widely (US$16-58) and was primarily determined by testing volume. Total diagnostic costs were 2.4-fold higher in Xpert clinics than in non-Xpert clinics; however, Xpert only increased diagnoses by 12%. The diagnostic costs of Xpert averaged US$119 per newly detected TB case, but were as high as US$885 at the center with the lowest volume of tests. Xpert testing can detect TB cases at reasonable cost, but may double diagnostic budgets for relatively small gains, with cost-effectiveness deteriorating with lower testing volumes.

  1. Diagnostic Accuracy of Obstructive Airway Adult Test for Diagnosis of Obstructive Sleep Apnea.

    PubMed

    Gasparini, Giulio; Vicini, Claudio; De Benedetto, Michele; Salamanca, Fabrizio; Sorrenti, Giovanni; Romandini, Mario; Bosi, Marcello; Saponaro, Gianmarco; Foresta, Enrico; Laforì, Andreina; Meccariello, Giuseppe; Bianchi, Alessandro; Toraldo, Domenico Maurizio; Campanini, Aldo; Montevecchi, Filippo; Rizzotto, Grazia; Cervelli, Daniele; Moro, Alessandro; Arigliani, Michele; Gobbi, Riccardo; Pelo, Sandro

    2015-01-01

    The gold standard for the diagnosis of Obstructive Sleep Apnea (OSA) is polysomnography, whose access is however reduced by costs and limited availability, so that additional diagnostic tests are needed. To analyze the diagnostic accuracy of the Obstructive Airway Adult Test (OAAT) compared to polysomnography for the diagnosis of OSA in adult patients. Ninety patients affected by OSA verified with polysomnography (AHI ≥ 5) and ten healthy patients, randomly selected, were included and all were interviewed by one blind examiner with OAAT questions. The Spearman rho, evaluated to measure the correlation between OAAT and polysomnography, was 0.72 (p < 0.01). The area under the ROC curve (95% CI) was the parameter to evaluate the accuracy of the OAAT: it was 0.91 (0.81-1.00) for the diagnosis of OSA (AHI ≥ 5), 0.90 (0.82-0.98) for moderate OSA (AHI ≥ 15), and 0.84 (0.76-0.92) for severe OSA (AHI ≥ 30). The OAAT has shown a high correlation with polysomnography and also a high diagnostic accuracy for the diagnosis of OSA. It has also been shown to be able to discriminate among the different degrees of severity of OSA. Additional large studies aiming to validate this questionnaire as a screening or diagnostic test are needed.

  2. The AcCell series 2000 as a support system for training and evaluation in educational and clinical settings.

    PubMed

    Greening, S E; Grohs, D H; Guidos, B J

    1997-01-01

    Providing effective training, retraining and evaluation programs, including proficiency testing programs, for cytoprofessionals is a challenge shared by many academic and clinical educators internationally. In cytopathology the quality of training has immediately transferable and critically important impacts on satisfactory performance in the clinical setting. Well-designed interactive computer-assisted instruction and testing programs have been shown to enhance initial learning and to reinforce factual and conceptual knowledge. Computer systems designed not only to promote diagnostic accuracy but to integrate and streamline work flow in clinical service settings are candidates for educational adaptation. The AcCell 2000 system, designed as a diagnostic screening support system, offers technology that is adaptable to educational needs during basic and in-service training as well as testing of screening proficiency in both locator and identification skills. We describe the considerations, approaches and applications of the AcCell 2000 system in education programs for both training and evaluation of gynecologic diagnostic screening proficiency.

  3. History and Evolution of the Barium Swallow for Evaluation of the Pharynx and Esophagus.

    PubMed

    Levine, Marc S; Rubesin, Stephen E

    2017-02-01

    This article reviews the history of the barium swallow from its early role in radiology to its current status as an important diagnostic test in modern radiology practice. Though a variety of diagnostic procedures can be performed to evaluate patients with dysphagia or other pharyngeal or esophageal symptoms, the barium study has evolved into a readily available, non-invasive, and cost-effective technique that can facilitate the selection of additional diagnostic tests and guide decisions about medical, endoscopic, or surgical management. This article focuses on the evolution of fluoroscopic equipment, radiography, and contrast media for evaluating the pharynx and esophagus, the importance of understanding pharyngoesophageal relationships, and major advances that have occurred in the radiologic diagnosis of select esophageal diseases, including gastroesophageal reflux disease, infectious esophagitis, eosinophilic esophagitis, esophageal carcinoma, and esophageal motility disorders.

  4. Imaging modalities for the non-invasive diagnosis of endometriosis.

    PubMed

    Nisenblat, Vicki; Bossuyt, Patrick M M; Farquhar, Cindy; Johnson, Neil; Hull, M Louise

    2016-02-26

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can be used to accurately diagnose endometriosis are available in clinical practice. This is the first review of diagnostic test accuracy of imaging tests for endometriosis that uses Cochrane methods to provide an update on the rapidly expanding literature in this field. • To provide estimates of the diagnostic accuracy of imaging modalities for the diagnosis of pelvic endometriosis, ovarian endometriosis and deeply infiltrating endometriosis (DIE) versus surgical diagnosis as a reference standard.• To describe performance of imaging tests for mapping of deep endometriotic lesions in the pelvis at specific anatomical sites.Imaging tests were evaluated as replacement tests for diagnostic surgery and as triage tests that would assist decision making regarding diagnostic surgery for endometriosis. We searched the following databases to 20 April 2015: MEDLINE, CENTRAL, EMBASE, CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, MEDION, DARE, and PubMed. Searches were not restricted to a particular study design or language nor to specific publication dates. The search strategy incorporated words in the title, abstracts, text words across the record and medical subject headings (MeSH). We considered published peer-reviewed cross-sectional studies and randomised controlled trials of any size that included prospectively recruited women of reproductive age suspected of having one or more of the following target conditions: endometrioma, pelvic endometriosis, DIE or endometriotic lesions at specific intrapelvic anatomical locations. We included studies that compared the diagnostic test accuracy of one or more imaging modalities versus findings of surgical visualisation of endometriotic lesions. Two review authors independently collected and performed a quality assessment of data from each study. For each imaging test, data were classified as positive or negative for surgical detection of endometriosis, and sensitivity and specificity estimates were calculated. If two or more tests were evaluated in the same cohort, each was considered as a separate data set. We used the bivariate model to obtain pooled estimates of sensitivity and specificity when sufficient data sets were available. Predetermined criteria for a clinically useful imaging test to replace diagnostic surgery included sensitivity ≥ 94% and specificity ≥ 79%. Criteria for triage tests were set at sensitivity ≥ 95% and specificity ≥ 50%, ruling out the diagnosis with a negative result (SnNout test - if sensitivity is high, a negative test rules out pathology) or at sensitivity ≥ 50% with specificity ≥ 95%, ruling in the diagnosis with a positive result (SpPin test - if specificity is high, a positive test rules in pathology). We included 49 studies involving 4807 women: 13 studies evaluated pelvic endometriosis, 10 endometriomas and 15 DIE, and 33 studies addressed endometriosis at specific anatomical sites. Most studies were of poor methodological quality. The most studied modalities were transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI), with outcome measures commonly demonstrating diversity in diagnostic estimates; however, sources of heterogeneity could not be reliably determined. No imaging test met the criteria for a replacement or triage test for detecting pelvic endometriosis, albeit TVUS approached the criteria for a SpPin triage test. For endometrioma, TVUS (eight studies, 765 participants; sensitivity 0.93 (95% confidence interval (CI) 0.87, 0.99), specificity 0.96 (95% CI 0.92, 0.99)) qualified as a SpPin triage test and approached the criteria for a replacement and SnNout triage test, whereas MRI (three studies, 179 participants; sensitivity 0.95 (95% CI 0.90, 1.00), specificity 0.91 (95% CI 0.86, 0.97)) met the criteria for a replacement and SnNout triage test and approached the criteria for a SpPin test. For DIE, TVUS (nine studies, 12 data sets, 934 participants; sensitivity 0.79 (95% CI 0.69, 0.89) and specificity 0.94 (95% CI 0.88, 1.00)) approached the criteria for a SpPin triage test, and MRI (six studies, seven data sets, 266 participants; sensitivity 0.94 (95% CI 0.90, 0.97), specificity 0.77 (95% CI 0.44, 1.00)) approached the criteria for a replacement and SnNout triage test. Other imaging tests assessed in small individual studies could not be statistically evaluated.TVUS met the criteria for a SpPin triage test in mapping DIE to uterosacral ligaments, rectovaginal septum, vaginal wall, pouch of Douglas (POD) and rectosigmoid. MRI met the criteria for a SpPin triage test for POD and vaginal and rectosigmoid endometriosis. Transrectal ultrasonography (TRUS) might qualify as a SpPin triage test for rectosigmoid involvement but could not be adequately assessed for other anatomical sites because heterogeneous data were scant. Multi-detector computerised tomography enema (MDCT-e) displayed the highest diagnostic performance for rectosigmoid and other bowel endometriosis and met the criteria for both SpPin and SnNout triage tests, but studies were too few to provide meaningful results.Diagnostic accuracies were higher for TVUS with bowel preparation (TVUS-BP) and rectal water contrast (RWC-TVS) and for 3.0TMRI than for conventional methods, although the paucity of studies precluded statistical evaluation. None of the evaluated imaging modalities were able to detect overall pelvic endometriosis with enough accuracy that they would be suggested to replace surgery. Specifically for endometrioma, TVUS qualified as a SpPin triage test. MRI displayed sufficient accuracy to suggest utility as a replacement test, but the data were too scant to permit meaningful conclusions. TVUS could be used clinically to identify additional anatomical sites of DIE compared with MRI, thus facilitating preoperative planning. Rectosigmoid endometriosis was the only site that could be accurately mapped by using TVUS, TRUS, MRI or MDCT-e. Studies evaluating recent advances in imaging modalities such as TVUS-BP, RWC-TVS, 3.0TMRI and MDCT-e were observed to have high diagnostic accuracies but were too few to allow prudent evaluation of their diagnostic role. In view of the low quality of most of the included studies, the findings of this review should be interpreted with caution. Future well-designed diagnostic studies undertaken to compare imaging tests for diagnostic test accuracy and costs are recommended.

  5. [Potentialities of the vegetative resonance test for diagnostics of hyperplastic processes in vocal folds].

    PubMed

    Ukhankova, N I; Sotskaia, T Iu

    2010-01-01

    The objective of the present study was to evaluate potentialities of the vegetative resonance test (VRT) for the elucidation of metabolic aspects of the inflammatory process in different forms of chronic vocal fold hyperplasty. The proposed diagnostic criteria characterize the inflammatory process in the larynx, specific features of metabolism in patients presenting with catarrhal and oedematopolypous laryngitis, characteristic changes in oedematofibrous and fibrous polyps. The use of VRT allowed diagnostic criteria for precarcinogenic conditions in the larynx to be developed.

  6. Development and Evaluation of the Diagnostic Power for a Computer-Based Two-Tier Assessment

    ERIC Educational Resources Information Center

    Lin, Jing-Wen

    2016-01-01

    This study adopted a quasi-experimental design with follow-up interview to develop a computer-based two-tier assessment (CBA) regarding the science topic of electric circuits and to evaluate the diagnostic power of the assessment. Three assessment formats (i.e., paper-and-pencil, static computer-based, and dynamic computer-based tests) using…

  7. Clinical review: Distinguishing constitutional delay of growth and puberty from isolated hypogonadotropic hypogonadism: critical appraisal of available diagnostic tests.

    PubMed

    Harrington, Jennifer; Palmert, Mark R

    2012-09-01

    Determining the etiology of delayed puberty during initial evaluation can be challenging. Specifically, clinicians often cannot distinguish constitutional delay of growth and puberty (CDGP) from isolated hypogonadotropic hypogonadism (IHH), with definitive diagnosis of IHH awaiting lack of spontaneous puberty by age 18 yr. However, the ability to make a timely, correct diagnosis has important clinical implications. The aim was to describe and evaluate the literature regarding the ability of diagnostic tests to distinguish CDGP from IHH. A PubMed search was performed using key words "puberty, delayed" and "hypogonadotropic hypogonadism," and citations within retrieved articles were reviewed to identify studies that assessed the utility of basal and stimulation tests in the diagnosis of delayed puberty. Emphasis was given to a test's ability to distinguish prepubertal adolescents with CDGP from those with IHH. Basal gonadotropin and GnRH stimulation tests have limited diagnostic specificity, with overlap in gonadotropin levels between adolescents with CDGP and IHH. Stimulation tests using more potent GnRH agonists and/or human chorionic gonadotropin may have better discriminatory value, but small study size, lack of replication of diagnostic thresholds, and prolonged protocols limit clinical application. A single inhibin B level in two recent studies demonstrated good differentiation between groups. Distinguishing IHH from CDGP is an important clinical issue. Basal inhibin B may offer a simple, discriminatory test if results from recent studies are replicated. However, current literature does not allow for recommendation of any diagnostic test for routine clinical use, making this an important area for future investigation.

  8. Evaluation of Commercially Available Diagnostic Tests for the Detection of Dengue Virus NS1 Antigen and Anti-Dengue Virus IgM Antibody

    PubMed Central

    Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.

    2014-01-01

    Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157

  9. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial

    PubMed Central

    Di Santo, Pietro; Harnett, David T.; Simard, Trevor; Ramirez, F. Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G.; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong

    2018-01-01

    BACKGROUND: Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. METHODS: We compared the modified Allen test with a smartphone heart rate–monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient’s index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate–monitoring application. RESULTS: Among 438 patients who were included in the study, we found that the heart rate–monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). INTERPRETATION: A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient’s bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. PMID:29615421

  10. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial.

    PubMed

    Di Santo, Pietro; Harnett, David T; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong; Hibbert, Benjamin

    2018-04-03

    Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. We compared the modified Allen test with a smartphone heart rate-monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient's index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate-monitoring application. Among 438 patients who were included in the study, we found that the heart rate-monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient's bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. © 2018 Joule Inc. or its licensors.

  11. Next Generation Diagnostic System (NGDS) Increment 1 Early Fielding Report

    DTIC Science & Technology

    2017-06-07

    for a NGDS Warrior Panel test FOB 5- Marburg Virus 2 – Marburg 1 – Staph infection 1 – Flu Yes 5 days post -exposure 70 minutes after...Director, Operational Test and Evaluation Next Generation Diagnostic System (NGDS) Increment 1 Early Fielding Report   June 2017...Increment 1 Early Fielding Report Summary This report provides the Director, Operational Test and Evaluation’s (DOT&E) operational assessment of the

  12. [Companion diagnostics in the era of personalized medicine--chairmen's introductory remarks].

    PubMed

    Fukutsuka, Katsuhiro; Takubo, Takayuki

    2014-04-01

    Personalized medicine is a medical model that proposes the customization of treatment for individual patients. In this model, diagnostic tests are essential for selecting safer and more efficacious treatments. The term "companion diagnostics" has been used to describe these tests, whereby molecular assays that measure the levels of proteins or specific gene mutations are used to provide a specific therapy for an individual by stratifying the disease status, selecting the proper medication, and tailoring dosages. Examples of companion diagnostics in the field of cancer medicine for molecular targeted therapy include tests for the ALK-fusion gene in non-small cell lung cancer and expression of CCR4 in adult T-cell leukemia. For breast cancer, the expression of HER2 protein is evaluated by immunohistochemistry (IHC), and gene amplification of HER2 is tested by fluorescence in situ hybridization (FISH); both tests consist of pre-analysis, analysis, and post-analysis processes that require quality control to ensure the reliability of the results. This symposium includes: 1) future aspects of companion diagnostics addressing many of the problems that must be overcome, 2) companion diagnostics using FISH focusing on HER2 amplification and ALK alteration, 3) newly developed diagnostic tests using tumor specimens and cell-free DNA in serum, and 4) CCR4 expression detected by IHC and flow cytometry.

  13. Does McNemar's test compare the sensitivities and specificities of two diagnostic tests?

    PubMed

    Kim, Soeun; Lee, Woojoo

    2017-02-01

    McNemar's test is often used in practice to compare the sensitivities and specificities for the evaluation of two diagnostic tests. For correct evaluation of accuracy, an intuitive recommendation is to test the diseased and the non-diseased groups separately so that the sensitivities can be compared among the diseased, and specificities can be compared among the healthy group of people. This paper provides a rigorous theoretical framework for this argument and study the validity of McNemar's test regardless of the conditional independence assumption. We derive McNemar's test statistic under the null hypothesis considering both assumptions of conditional independence and conditional dependence. We then perform power analyses to show how the result is affected by the amount of the conditional dependence under alternative hypothesis.

  14. Diagnostic grand rounds: a new teaching concept to train diagnostic reasoning.

    PubMed

    Stieger, Stefan; Praschinger, Andrea; Kletter, Kurt; Kainberger, Franz

    2011-06-01

    Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  15. Diagnostic reasoning by hospital pharmacists: assessment of attitudes, knowledge, and skills.

    PubMed

    Chernushkin, Kseniya; Loewen, Peter; de Lemos, Jane; Aulakh, Amneet; Jung, Joanne; Dahri, Karen

    2012-07-01

    Hospital pharmacists participate in activities that may be considered diagnostic. Two reasoning approaches to diagnosis have been described: non-analytic and analytic. Of the 6 analytic traditions, the probabilistic tradition has been shown to improve diagnostic accuracy and reduce unnecessary testing. To the authors' knowledge, pharmacists' attitudes toward having a diagnostic role and their diagnostic knowledge and skills have never been studied. To describe pharmacists' attitudes toward the role of diagnosis in pharmacotherapeutic problem-solving and to characterize the extent of pharmacists' knowledge and skills related to diagnostic literacy. Pharmacists working within Lower Mainland Pharmacy Services (British Columbia) who spent at least 33% of their time in direct patient care were invited to participate in a prospective observational survey. The survey sought information about demographic characteristics and attitudes toward diagnosis. Diagnostic knowledge and skills were tested by means of 3 case scenarios. The analysis included simple descriptive statistics and inferential statistics to evaluate relationships between responses and experience and training. Of 266 pharmacists invited to participate, 94 responded. The attitudes section of the survey was completed by 90 pharmacists; of these, 80 (89%) agreed with the definition of "diagnosis" proposed in the survey, and 83 (92%) agreed that it is important for pharmacists to have diagnosis-related skills. Respondents preferred an analytic to a non-analytic approach to diagnostic decision-making. The probabilistic tradition was not the preferred method in any of the 3 cases. In evaluating 5 clinical scenarios that might require diagnostic skills, on average 84% of respondents agreed that they should be involved in assessing such problems. Respondents' knowledge of and ability to apply probabilistic diagnostic tools were highest for test sensitivity (average of 61% of respondents with the correct answers) and lower for test specificity (average of 48% with correct answers) and likelihood ratios (average of 39% with correct answers). Respondents to this survey strongly believed that diagnostic skills were important for solving drug-related problems, but they demonstrated low levels of knowledge and ability to apply concepts of probabilistic diagnostic reasoning. Opportunities to expand pharmacists' knowledge of diagnostic reasoning exist, and the findings reported here indicate that pharmacists would consider such professional development valuable.

  16. Bovine paratuberculosis: a review of the advantages and disadvantages of different diagnostic tests.

    PubMed

    Gilardoni, Liliana R; Paolicchi, Fernando A; Mundo, Silvia L

    2012-01-01

    Paratuberculosis (PTB), or Johne's disease, is a chronic infectious granulomatous enteritis of ruminants, caused by Mycobacterium avium subspecies paratuberculosis (Map). It is characterized by diarrhea and progressive cachexia, which may cause the death of the animal. Calves are the most susceptible to infection. Infected animals excrete Map mainly by the feces. PTB is endemic worldwide, with high prevalence levels, strong economic impact and public health relevance because of its possible association with Crohn's disease. Although the current reference diagnostic test is identification of Map in the bacterial culture, there are different diagnostic tests to identify infected individuals and/or herds. The sensitivity and specificity of these tests vary according to the stage of the disease in the animals to be evaluated. The correct choice and application of each of these diagnostic tests will ensure their success and may allow to establish a control program. The aim of this work is to review and discuss the different diagnostic tests used in the detection of Map-infected animals, focusing on their advantages and disadvantages.

  17. Clinical usefulness of a biomarker-based diagnostic test for acute stroke: the Biomarker Rapid Assessment in Ischemic Injury (BRAIN) study.

    PubMed

    Laskowitz, Daniel T; Kasner, Scott E; Saver, Jeffrey; Remmel, Kerri S; Jauch, Edward C

    2009-01-01

    One of the significant limitations in the evaluation and management of patients with suspected acute cerebral ischemia is the absence of a widely available, rapid, and sensitive diagnostic test. The objective of the current study was to assess whether a test using a panel of biomarkers might provide useful diagnostic information in the early evaluation of stroke by differentiating patients with cerebral ischemia from other causes of acute neurological deficit. A total of 1146 patients presenting with neurological symptoms consistent with possible stroke were prospectively enrolled at 17 different sites. Timed blood samples were assayed for matrix metalloproteinase 9, brain natriuretic factor, d-dimer, and protein S100beta. A separate cohort of 343 patients was independently enrolled to validate the multiple biomarker model approach. A diagnostic tool incorporating the values of matrix metalloproteinase 9, brain natriuretic factor, d-dimer, and S-100beta into a composite score was sensitive for acute cerebral ischemia. The multivariate model demonstrated modest discriminative capabilities with an area under the receiver operating characteristic curve of 0.76 for hemorrhagic stroke and 0.69 for all stroke (likelihood test P<0.001). When the threshold for the logistic model was set at the first quartile, this resulted in a sensitivity of 86% for detecting all stroke and a sensitivity of 94% for detecting hemorrhagic stroke. Moreover, results were reproducible in a separate cohort tested on a point-of-care platform. These results suggest that a biomarker panel may add valuable and time-sensitive diagnostic information in the early evaluation of stroke. Such an approach is feasible on a point-of-care platform. The rapid identification of patients with suspected stroke would expand the availability of time-limited treatment strategies. Although the diagnostic accuracy of the current panel is clearly imperfect, this study demonstrates the feasibility of incorporating a biomarker based point-of-care algorithm with readily available clinical data to aid in the early evaluation and management of patients at high risk for cerebral ischemia.

  18. Interactive visualisation for interpreting diagnostic test accuracy study results.

    PubMed

    Fanshawe, Thomas R; Power, Michael; Graziadio, Sara; Ordóñez-Mena, José M; Simpson, John; Allen, Joy

    2018-02-01

    Information about the performance of diagnostic tests is typically presented in the form of measures of test accuracy such as sensitivity and specificity. These measures may be difficult to translate directly into decisions about patient treatment, for which information presented in the form of probabilities of disease after a positive or a negative test result may be more useful. These probabilities depend on the prevalence of the disease, which is likely to vary between populations. This article aims to clarify the relationship between pre-test (prevalence) and post-test probabilities of disease, and presents two free, online interactive tools to illustrate this relationship. These tools allow probabilities of disease to be compared with decision thresholds above and below which different treatment decisions may be indicated. They are intended to help those involved in communicating information about diagnostic test performance and are likely to be of benefit when teaching these concepts. A substantive example is presented using C reactive protein as a diagnostic marker for bacterial infection in the older adult population. The tools may also be useful for manufacturers of clinical tests in planning product development, for authors of test evaluation studies to improve reporting and for users of test evaluations to facilitate interpretation and application of the results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease.

    PubMed

    Matías-Guiu, Jordi A; Valles-Salgado, María; Rognoni, Teresa; Hamre-Gil, Frank; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Our aim was to evaluate and compare the diagnostic properties of 5 screening tests for the diagnosis of mild Alzheimer disease (AD). We conducted a prospective and cross-sectional study of 92 patients with mild AD and of 68 healthy controls from our Department of Neurology. The diagnostic properties of the following tests were compared: Mini-Mental State Examination (MMSE), Addenbrooke's Cognitive Examination III (ACE-III), Memory Impairment Screen (MIS), Montreal Cognitive Assessment (MoCA), and Rowland Universal Dementia Assessment Scale (RUDAS). All tests yielded high diagnostic accuracy, with the ACE-III achieving the best diagnostic properties. The area under the curve was 0.897 for the ACE-III, 0.889 for the RUDAS, 0.874 for the MMSE, 0.866 for the MIS, and 0.856 for the MoCA. The Mini-ACE score from the ACE-III showed the highest diagnostic capacity (area under the curve 0.939). Memory scores of the ACE-III and of the RUDAS showed a better diagnostic accuracy than those of the MMSE and of the MoCA. All tests, especially the ACE-III, conveyed a higher diagnostic accuracy in patients with full primary education than in the less educated group. Implementing normative data improved the diagnostic accuracy of the ACE-III but not that of the other tests. The ACE-III achieved the highest diagnostic accuracy. This better discrimination was more evident in the more educated group. © 2017 S. Karger AG, Basel.

  20. Evaluating Malaria Prevalence Using Clinical Diagnosis Compared with Microscopy and Rapid Diagnostic Tests in a Tertiary Healthcare Facility in Rivers State, Nigeria.

    PubMed

    Wogu, M N; Nduka, F O

    2018-01-01

    The World Health Organization's policy on laboratory test of all suspected malaria cases before treatment has not yielded significant effects in several rural areas of Sub-Saharan Africa due to inadequate diagnostic infrastructure, leading to high morbidity and mortality rates. A cross-sectional randomized study was conducted to evaluate the validity of clinical malaria diagnosis through comparison with microscopy and rapid diagnostic test kits (RDTs) using 1000 consenting outpatients of a tertiary hospital in Nigeria. Physicians conducted clinical diagnosis, and blood samples were collected through venous procedure and analyzed for malaria parasites using Giemsa microscopy and RDT kits. Microscopy was considered the diagnostic "gold standard" and all data obtained were statistically analyzed using Chi-square test with a P value <0.05 considered significant. Malaria prevalence values of 20.1%, 43.1%, and 29.7% were obtained for clinical diagnosis, microscopy, and RDTs, respectively ( P < 0.05). Values of 47.2%, 95.9%, and 77.8% were obtained for sensitivity, specificity, and diagnostic accuracy, respectively, in clinical diagnosis, while RDTs had sensitivity, specificity, and diagnostic accuracy values of 73.7%, 97.3%, and 88.3%, respectively, when compared to microscopy ( P < 0.05). Clinical diagnosed malaria cases should be confirmed with a parasite-based laboratory diagnosis and more qualitative research is needed to explore why clinicians still use clinical diagnosis despite reported cases of its ineffectiveness.

  1. Neuropathy Tests

    MedlinePlus

    ... Mutation Mycophenolic Acid Mycoplasma Myoglobin Nicotine and Cotinine Non-High Density Lipoprotein Cholesterol Opioid Testing Osmolality Ova ... that make neuropathy worse Detect and evaluate complications Non-laboratory tests The diagnostic workup for neuropathy begins ...

  2. Assessment of the diagnostic value of a urinary adipsin rapid strip test for pre-eclampsia: A prospective multicenter study.

    PubMed

    Peng, Bing; Zhang, Li; Yan, Jianying; Qi, Hongbo; Zhang, Weiyuan; Fan, Ling; Hu, Yayi; Lin, Li; Li, Xiaotian; Hu, Rong; Xie, Lan; Zhang, Jianping; Wu, Yanqiao; Li, Li; Zhou, Rong

    2017-01-01

    The purpose of the present study was to evaluate the clinical value of the rapid strip test of urinary adipsin for the quick diagnosis of pre-eclampsia. In a multicenter diagnostic test study, we studied the diagnostic accuracy of the rapid strip test of urinary adipsin in women presenting with pre-eclampsia. A total of 204 pre-eclampsia patients and 254 healthy pregnant women were recruited for this study, respectively. The rapid strip test of urinary adipsin was used to detect the adipsin in the urine of each patient. The diagnostic value of the rapid strip test of urinary adipsin for pre-eclampsia was demonstrated by its high sensitivity and specificity (95.10% and 97.64%, respectively). The diagnostic accuracy was 96.51%. The consistency analysis showed that the kappa value was 0.93 compared with the gold standard diagnosis of pre-eclampsia. The rapid strip test of urinary adipsin is a non-invasive test for the diagnosis of pre-eclampsia with high sensitivity and specificity. It could help the quick diagnosis of pre-eclampsia in clinical practice greatly. © 2016 Japan Society of Obstetrics and Gynecology.

  3. The Importance of Rare Subtypes in Diagnosis and Treatment of Peripheral Neuropathy: A Review.

    PubMed

    Callaghan, Brian C; Price, Raymond S; Chen, Kevin S; Feldman, Eva L

    2015-12-01

    Peripheral neuropathy is a prevalent condition that usually warrants a thorough history and examination but has limited diagnostic evaluation. However, rare localizations of peripheral neuropathy often require more extensive diagnostic testing and different treatments. To describe rare localizations of peripheral neuropathy, including the appropriate diagnostic evaluation and available treatments. References were identified from PubMed searches conducted on May 29, 2015, with an emphasis on systematic reviews and randomized clinical trials. Articles were also identified through the use of the authors' own files. Search terms included common rare neuropathy localizations and their causes, as well as epidemiology, pathophysiology, diagnosis, and treatment. Diffuse, nonlength-dependent neuropathies, multiple mononeuropathies, polyradiculopathies, plexopathies, and radiculoplexus neuropathies are rare peripheral neuropathy localizations that often require extensive diagnostic testing. Atypical neuropathy features, such as acute/subacute onset, asymmetry, and/or motor predominant signs, are frequently present. The most common diffuse, nonlength-dependent neuropathies are Guillain-Barré syndrome, chronic inflammatory demyelinating polyneuropathy, multifocal motor neuropathy, and amyotrophic lateral sclerosis. Effective disease-modifying therapies exist for many diffuse, nonlength-dependent neuropathies including Guillain-Barré syndrome, chronic inflammatory demyelinating polyneuropathy, multifocal motor neuropathy, and some paraprotein-associated demyelinating neuropathies. Vasculitic neuropathy (multiple mononeuropathy) also has efficacious treatment options, but definitive evidence of a treatment effect for IgM anti-MAG neuropathy and diabetic amyotrophy (radiculoplexus neuropathy) is lacking. Recognition of rare localizations of peripheral neuropathy is essential given the implications for diagnostic testing and treatment. Electrodiagnostic studies are an important early step in the diagnostic evaluation and provide information on the localization and pathophysiology of nerve injury.

  4. A Self-Diagnostic System for the M6 Accelerometer

    NASA Technical Reports Server (NTRS)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  5. Looking for trouble? Diagnostics expanding disease and producing patients.

    PubMed

    Hofmann, Bjørn

    2018-05-23

    Novel tests give great opportunities for earlier and more precise diagnostics. At the same time, new tests expand disease, produce patients, and cause unnecessary harm in overdiagnosis and overtreatment. How can we evaluate diagnostics to obtain the benefits and avoid harm? One way is to pay close attention to the diagnostic process and its core concepts. Doing so reveals 3 errors that expand disease and increase overdiagnosis. The first error is to decouple diagnostics from harm, eg, by diagnosing insignificant conditions. The second error is to bypass proper validation of the relationship between test indicator and disease, eg, by introducing biomarkers for Alzheimer's disease before the tests are properly validated. The third error is to couple the name of disease to insignificant or indecisive indicators, eg, by lending the cancer name to preconditions, such as ductal carcinoma in situ. We need to avoid these errors to promote beneficial testing, bar harmful diagnostics, and evade unwarranted expansion of disease. Accordingly, we must stop identifying and testing for conditions that are only remotely associated with harm. We need more stringent verification of tests, and we must avoid naming indicators and indicative conditions after diseases. If not, we will end like ancient tragic heroes, succumbing because of our very best abilities. © 2018 John Wiley & Sons, Ltd.

  6. Testing Expert-Based versus Student-Based Cognitive Models for a Grade 3 Diagnostic Mathematics Assessment

    ERIC Educational Resources Information Center

    Roduta Roberts, Mary; Alves, Cecilia B.; Chu, Man-Wai; Thompson, Margaret; Bahry, Louise M.; Gotzmann, Andrea

    2014-01-01

    The purpose of this study was to evaluate the adequacy of three cognitive models, one developed by content experts and two generated from student verbal reports for explaining examinee performance on a grade 3 diagnostic mathematics test. For this study, the items were developed to directly measure the attributes in the cognitive model. The…

  7. Utility of a point-of-care malaria rapid diagnostic test for excluding malaria as the cause of fever among HIV-positive adults in rural Rakai, Uganda.

    PubMed

    Mills, Lisa A; Kagaayi, Joseph; Nakigozi, Gertrude; Galiwango, Ronald M; Ouma, Joseph; Shott, Joseph P; Ssempijja, Victor; Gray, Ronald H; Wawer, Maria J; Serwadda, David; Quinn, Thomas C; Reynolds, Steven J

    2010-01-01

    We compared results of a malaria rapid diagnostic test (Binax Now Malaria, Binax-M, Inverness Medical Innovations, Inc., Waltham, MA) performed at rural mobile clinics in Uganda by clinicians evaluating febrile adult HIV patients to thick smear evaluated at a central laboratory by trained microscopists. Two hundred forty-six samples were analyzed, including 14 (5.7%) which were thick-smear positive for falciparum malaria. Sensitivity of Binax-M compared with thick smear was 85.7% (95% CI: 57.2-98.2), specificity 97.8% (95% CI: 94.9-99.3), positive and negative predictive values were 70.6% (95% CI: 44.0-89.7) and 99.1% (95% CI: 96.8-99.9), respectively. The rapid diagnostic test accurately ruled malaria "in or out" at the point-of-care, facilitating appropriate clinical management and averting unnecessary anti-malarial therapy.

  8. Diagnostic Tests to Support Late-Stage Control Programs for Schistosomiasis and Soil-Transmitted Helminthiases.

    PubMed

    Hawkins, Kenneth R; Cantera, Jason L; Storey, Helen L; Leader, Brandon T; de Los Santos, Tala

    2016-12-01

    Global efforts to address schistosomiasis and soil-transmitted helminthiases (STH) include deworming programs for school-aged children that are made possible by large-scale drug donations. Decisions on these mass drug administration (MDA) programs currently rely on microscopic examination of clinical specimens to determine the presence of parasite eggs. However, microscopy-based methods are not sensitive to the low-intensity infections that characterize populations that have undergone MDA. Thus, there has been increasing recognition within the schistosomiasis and STH communities of the need for improved diagnostic tools to support late-stage control program decisions, such as when to stop or reduce MDA. Failure to adequately address the need for new diagnostics could jeopardize achievement of the 2020 London Declaration goals. In this report, we assess diagnostic needs and landscape potential solutions and determine appropriate strategies to improve diagnostic testing to support control and elimination programs. Based upon literature reviews and previous input from experts in the schistosomiasis and STH communities, we prioritized two diagnostic use cases for further exploration: to inform MDA-stopping decisions and post-MDA surveillance. To this end, PATH has refined target product profiles (TPPs) for schistosomiasis and STH diagnostics that are applicable to these use cases. We evaluated the limitations of current diagnostic methods with regards to these use cases and identified candidate biomarkers and diagnostics with potential application as new tools. Based on this analysis, there is a need to develop antigen-detecting rapid diagnostic tests (RDTs) with simplified, field-deployable sample preparation for schistosomiasis. Additionally, there is a need for diagnostic tests that are more sensitive than the current methods for STH, which may include either a field-deployable molecular test or a simple, low-cost, rapid antigen-detecting test.

  9. [Diagnostic kits in parasitology: which controls?].

    PubMed

    Rossi, P

    2004-06-01

    The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic diseases are not available at present, except for Toxoplasma antibodies. The first international standard reagent for Anti-Toxoplasma Serum was established in 1968 and at present, an international standard reference serum, Anti-toxoplasma serum, human TOXM is available at the National Institute for Biological Standards and Control (NIBSC) in UK. Several collaborative, multicenter studies were carried out to assess the performance of different methods and commercial tests for the diagnosis of toxoplasmosis, by providing to participating laboratories a panel of well-defined sera to be tested. A four-phase process following well-accepted methodological standards for the development of diagnostics, analogous to those internationally accepted for drugs and vaccines was recently proposed. The pre-clinical evaluation, the analytic study to assess sensitivity, specificity, predictive values in laboratory (phase I), should be followed by a proof of principle study to distinguish diseased from healthy persons in easily accessible populations (phase II). The evaluation of test performance in populations of intended use (phase III), and finally the delineation of cost-effectiveness and societal impact of new tests in comparison with existing tools (phase IV) should complete the validation procedure. In this context, national regulatory agencies play a major role in pre-market approval and post-market surveillance of IVDs. The European Community in 1998 approved a directive (Directive 98/79/EC) which rules the marketing of IVD medical devices, in order to harmonise the performance levels and standards in European countries. But, among IVDs for parasitic diseases, only those to detect congenital toxoplasmosis are submitted to defined procedures to provide the verification of products before their placing on the market and the surveillance after their marketing by a notified body, which perform appropriate examinations, tests and inspections to production facilities to verify if the device meets the requirements of the directive. In U.S.A., the Food and Drug Administration (FDA), through the Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD), provides a comprehensive and regulatory activity for IVDs through pre-market evaluation and post-market surveillance. In developing countries, the scarcity of resources limits the procedures through which the national control authority can assure safety, quality and efficacy of products marketed, both imported and locally manufactured.

  10. Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.

    PubMed

    Shivalli, Siddharudha

    2016-05-12

    Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.

  11. The methodological quality of diagnostic test accuracy studies for musculoskeletal conditions can be improved.

    PubMed

    Henschke, Nicholas; Keuerleber, Julia; Ferreira, Manuela; Maher, Christopher G; Verhagen, Arianne P

    2014-04-01

    To provide an overview of reporting and methodological quality in diagnostic test accuracy (DTA) studies in the musculoskeletal field and evaluate the use of the QUality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist. A literature review identified all systematic reviews that evaluated the accuracy of clinical tests to diagnose musculoskeletal conditions and used the QUADAS checklist. Two authors screened all identified reviews and extracted data on the target condition, index tests, reference standard, included studies, and QUADAS items. A descriptive analysis of the QUADAS checklist was performed, along with Rasch analysis to examine the construct validity and internal reliability. A total of 19 systematic reviews were included, which provided data on individual items of the QUADAS checklist for 392 DTA studies. In the musculoskeletal field, uninterpretable or intermediate test results are commonly not reported, with 175 (45%) studies scoring "no" to this item. The proportion of studies fulfilling certain items varied from 22% (item 11) to 91% (item 3). The interrater reliability of the QUADAS checklist was good and Rasch analysis showed excellent construct validity and internal consistency. This overview identified areas where the reporting and performance of diagnostic studies within the musculoskeletal field can be improved. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Whole Exome Sequencing in Pediatric Neurology Patients: Clinical Implications and Estimated Cost Analysis.

    PubMed

    Nolan, Danielle; Carlson, Martha

    2016-06-01

    Genetic heterogeneity in neurologic disorders has been an obstacle to phenotype-based diagnostic testing. The authors hypothesized that information compiled via whole exome sequencing will improve clinical diagnosis and management of pediatric neurology patients. The authors performed a retrospective chart review of patients evaluated in the University of Michigan Pediatric Neurology clinic between 6/2011 and 6/2015. The authors recorded previous diagnostic testing, indications for whole exome sequencing, and whole exome sequencing results. Whole exome sequencing was recommended for 135 patients and obtained in 53 patients. Insurance barriers often precluded whole exome sequencing. The most common indication for whole exome sequencing was neurodevelopmental disorders. Whole exome sequencing improved the presumptive diagnostic rate in the patient cohort from 25% to 48%. Clinical implications included family planning, medication selection, and systemic investigation. Compared to current second tier testing, whole exome sequencing can result in lower long-term charges and more timely diagnosis. Overcoming barriers related to whole exome sequencing insurance authorization could allow for more efficient and fruitful diagnostic neurological evaluations. © The Author(s) 2016.

  13. Network meta-analysis of diagnostic test accuracy studies identifies and ranks the optimal diagnostic tests and thresholds for health care policy and decision-making.

    PubMed

    Owen, Rhiannon K; Cooper, Nicola J; Quinn, Terence J; Lees, Rosalind; Sutton, Alex J

    2018-07-01

    Network meta-analyses (NMA) have extensively been used to compare the effectiveness of multiple interventions for health care policy and decision-making. However, methods for evaluating the performance of multiple diagnostic tests are less established. In a decision-making context, we are often interested in comparing and ranking the performance of multiple diagnostic tests, at varying levels of test thresholds, in one simultaneous analysis. Motivated by an example of cognitive impairment diagnosis following stroke, we synthesized data from 13 studies assessing the efficiency of two diagnostic tests: Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA), at two test thresholds: MMSE <25/30 and <27/30, and MoCA <22/30 and <26/30. Using Markov chain Monte Carlo (MCMC) methods, we fitted a bivariate network meta-analysis model incorporating constraints on increasing test threshold, and accounting for the correlations between multiple test accuracy measures from the same study. We developed and successfully fitted a model comparing multiple tests/threshold combinations while imposing threshold constraints. Using this model, we found that MoCA at threshold <26/30 appeared to have the best true positive rate, whereas MMSE at threshold <25/30 appeared to have the best true negative rate. The combined analysis of multiple tests at multiple thresholds allowed for more rigorous comparisons between competing diagnostics tests for decision making. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Accuracy of physical examination for chronic lumbar radiculopathy

    PubMed Central

    2013-01-01

    Background Clinical examination of patients with chronic lumbar radiculopathy aims to clarify whether there is nerve root impingement. The aims of this study were to investigate the association between findings at clinical examination and nerve root impingement, to evaluate the accuracy of clinical index tests in a specialised care setting, and to see whether imaging clarifies the cause of chronic radicular pain. Methods A total of 116 patients referred with symptoms of lumbar radiculopathy lasting more than 12 weeks and at least one positive index test were included. The tests were the straight leg raising test, and tests for motor muscle strength, dermatome sensory loss, and reflex impairment. Magnetic resonance imaging (n = 109) or computer tomography (n = 7) were imaging reference standards. Images were analysed at the level of single nerve root(s), and nerve root impingement was classified as present or absent. Sensitivities, specificities, and positive and negative likelihood ratios (LR) for detection of nerve root impingement were calculated for each individual index test. An overall clinical evaluation, concluding on the level and side of the radiculopathy, was performed. Results The prevalence of disc herniation was 77.8%. The diagnostic accuracy of individual index tests was low with no tests reaching positive LR >4.0 or negative LR <0.4. The overall clinical evaluation was slightly more accurate, with a positive LR of 6.28 (95% CI 1.06–37.21) for L4, 1.74 (95% CI 1.04–2.93) for L5, and 1.29 (95% CI 0.97–1.72) for S1 nerve root impingement. An overall clinical evaluation, concluding on the level and side of the radiculopathy was also performed, and receiver operating characteristic (ROC) analysis with area under the curve (AUC) calculation for diagnostic accuracy of this evaluation was performed. Conclusions The accuracy of individual clinical index tests used to predict imaging findings of nerve root impingement in patients with chronic lumbar radiculopathy is low when applied in specialised care, but clinicians’ overall evaluation improves diagnostic accuracy slightly. The tests are not very helpful in clarifying the cause of radicular pain, and are therefore inaccurate for guidance in the diagnostic workup of the patients. The study population was highly selected and therefore the results from this study should not be generalised to unselected patient populations in primary care nor to even more selected surgical populations. PMID:23837886

  15. Performance of seven serological assays for diagnosing tularemia

    PubMed Central

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  16. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    PubMed

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  17. Diagnostic and functional structure of a high-resolution thyroid nodule clinic.

    PubMed

    Fernández-García, José Carlos; Mancha-Doblas, Isabel; Ortega-Jiménez, María Victoria; Ruiz-Escalante, José Francisco; Castells-Fusté, Ignasi; Tofé-Povedano, Santiago; Argüelles-Jiménez, Iñaki; Tinahones, Francisco José

    2014-01-01

    Appearance of a thyroid nodule has become a daily occurrence in clinical practice. Adequate thyroid nodule assessment requires several diagnostic tests and multiple medical appointments, which results in a substantial delay in diagnosis. Implementation of a high-resolution thyroid nodule clinic largely avoids these drawbacks by condensing in a single appointment all tests required for adequate evaluation of thyroid nodule. This paper reviews the diagnostic and functional structure of a high-resolution thyroid nodule clinic. Copyright © 2013 SEEN. Published by Elsevier Espana. All rights reserved.

  18. Drug-device trials for infectious diseases: CDRH perspective.

    PubMed

    Meier, Kristen L; Gitterman, Steven

    2011-05-01

    Assessing the performance of new diagnostic tests for infectious diseases has traditionally focused on comparing the new assay against a reference standard such as culture. In this paper, we suggest that clinical trial designs with both a diagnostic and therapeutic component may be necessary to evaluate the safety and effectiveness of nonmicrobiologically based assays, with a specific emphasis on the test/marker-stratified design. General design challenges for trials of infectious diseases that simultaneously study both diagnostic and therapeutic components (eg, both devices and drugs) are also discussed.

  19. Evaluation Of The Diagnostic Performance Of A Multimedia Medical Communications System.

    NASA Astrophysics Data System (ADS)

    Robertson, John G.; Coristine, Marjorie; Goldberg, Morris; Beeton, Carolyn; Belanger, Garry; Tombaugh, Jo W.; Hickey, Nancy M.; Millward, Steven F.; Davis, Michael; Whittingham, David

    1989-05-01

    The central concern of radiologists when evaluating Picture Archiving Communication System (PACS) is the diagnostic performance of digital images compared to the original analog versions of the same images. Considerable work has been done comparing the ROC curves of various types of digital systems to the corresponding analog systems for the detection of specific phantoms or diseases. Although the studies may notify the radiologists that for a specific lesion a digital system may perform as well as the analog system, it tells the radiologists very little about the impact on diagnostic performance of a digital system in the general practice of radiology. We describe in this paper an alternative method for evaluating the diagnostic performance of a digital system and a preliminary experiment we conducted to test the methodology.

  20. Diagnostic Tools for Acute Anterior Cruciate Ligament Injury: GNRB, Lachman Test, and Telos.

    PubMed

    Ryu, Seung Min; Na, Ho Dong; Shon, Oog Jin

    2018-06-01

    The purpose of this study is to compare the accuracy of the GNRB arthrometer (Genourob), Lachman test, and Telos device (GmbH) in acute anterior cruciate ligament (ACL) injuries and to evaluate the accuracy of each diagnostic tool according to the length of time from injury to examination. From September 2015 to September 2016, 40 cases of complete ACL rupture were reviewed. We divided the time from injury to examination into three periods of 10 days each and analyzed the diagnostic tools according to the time frame. An analysis of the area under the curve (AUC) of a receiver operating characteristic curve showed that all diagnostic tools were fairly informative. The GNRB showed a higher AUC than other diagnostic tools. In 10 cases assessed within 10 days after injury, the GNRB showed statistically significant side-to-side difference in laxity (p<0.001), whereas the Telos test and Lachman test did not show significantly different laxity (p=0.541 and p=0.413, respectively). All diagnostic values of the GNRB were better than other diagnostic tools in acute ACL injuries. The GNRB was more effective in acute ACL injuries examined within 10 days of injury. The GNRB arthrometer can be a useful diagnostic tool for acute ACL injuries.

  1. Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design.

    PubMed

    Kim, Eunhee; Zhang, Zheng; Wang, Youdan; Zeng, Donglin

    2014-12-01

    Receiver operating characteristic (ROC) analysis is widely used to evaluate the performance of diagnostic tests with continuous or ordinal responses. A popular study design for assessing the accuracy of diagnostic tests involves multiple readers interpreting multiple diagnostic test results, called the multi-reader, multi-test design. Although several different approaches to analyzing data from this design exist, few methods have discussed the sample size and power issues. In this article, we develop a power formula to compare the correlated areas under the ROC curves (AUC) in a multi-reader, multi-test design. We present a nonparametric approach to estimate and compare the correlated AUCs by extending DeLong et al.'s (1988, Biometrics 44, 837-845) approach. A power formula is derived based on the asymptotic distribution of the nonparametric AUCs. Simulation studies are conducted to demonstrate the performance of the proposed power formula and an example is provided to illustrate the proposed procedure. © 2014, The International Biometric Society.

  2. Lessons learned developing a diagnostic tool for HIV-associated dementia feasible to implement in resource-limited settings: pilot testing in Kenya.

    PubMed

    Kwasa, Judith; Cettomai, Deanna; Lwanya, Edwin; Osiemo, Dennis; Oyaro, Patrick; Birbeck, Gretchen L; Price, Richard W; Bukusi, Elizabeth A; Cohen, Craig R; Meyer, Ana-Claire L

    2012-01-01

    To conduct a preliminary evaluation of the utility and reliability of a diagnostic tool for HIV-associated dementia (HAD) for use by primary health care workers (HCW) which would be feasible to implement in resource-limited settings. In resource-limited settings, HAD is an indication for anti-retroviral therapy regardless of CD4 T-cell count. Anti-retroviral therapy, the treatment for HAD, is now increasingly available in resource-limited settings. Nonetheless, HAD remains under-diagnosed likely because of limited clinical expertise and availability of diagnostic tests. Thus, a simple diagnostic tool which is practical to implement in resource-limited settings is an urgent need. A convenience sample of 30 HIV-infected outpatients was enrolled in Western Kenya. We assessed the sensitivity and specificity of a diagnostic tool for HAD as administered by a primary HCW. This was compared to an expert clinical assessment which included examination by a physician, neuropsychological testing, and in selected cases, brain imaging. Agreement between HCW and an expert examiner on certain tool components was measured using Kappa statistic. The sample was 57% male, mean age was 38.6 years, mean CD4 T-cell count was 323 cells/µL, and 54% had less than a secondary school education. Six (20%) of the subjects were diagnosed with HAD by expert clinical assessment. The diagnostic tool was 63% sensitive and 67% specific for HAD. Agreement between HCW and expert examiners was poor for many individual items of the diagnostic tool (K = .03-.65). This diagnostic tool had moderate sensitivity and specificity for HAD. However, reliability was poor, suggesting that substantial training and formal evaluations of training adequacy will be critical to enable HCW to reliably administer a brief diagnostic tool for HAD.

  3. Evaluation of the diagnostic yield of dental radiography and cone-beam computed tomography for the identification of anatomic landmarks in small to medium-sized brachycephalic dogs.

    PubMed

    Döring, Sophie; Arzi, Boaz; Barich, Catherine R; Hatcher, David C; Kass, Philip H; Verstraete, Frank J M

    2018-01-01

    OBJECTIVE To evaluate the diagnostic yield of dental radiography (Rad method) and 3 cone-beam CT (CBCT) methods for the identification of predefined anatomic landmarks in brachycephalic dogs. ANIMALS 19 client-owned brachycephalic dogs admitted for evaluation and treatment of dental disease. PROCEDURES 26 predefined anatomic landmarks were evaluated separately by use of the RAD method and 3 CBCT software modules (serial CBCT slices and custom cross sections, tridimensional rendering, and reconstructed panoramic views). A semiquantitative scoring system was used, and mean scores were calculated for each anatomic landmark and imaging method. The Friedman test was used to evaluate values for significant differences in diagnostic yield. For values that were significant, the Wilcoxon signed rank test was used with the Bonferroni-Holm multiple comparison adjustment to determine significant differences among each of the 6 possible pairs of diagnostic methods. RESULTS Differences of diagnostic yield among the Rad and 3 CBCT methods were significant for 19 of 26 anatomic landmarks. For these landmarks, Rad scores were significantly higher than scores for reconstructed panoramic views for 4 of 19 anatomic landmarks, but Rad scores were significantly lower than scores for reconstructed panoramic views for 8 anatomic landmarks, tridimensional rendering for 18 anatomic landmarks, and serial CBCT slices and custom cross sections for all 19 anatomic landmarks. CONCLUSIONS AND CLINICAL RELEVANCE CBCT methods were better suited than dental radiography for the identification of anatomic landmarks in brachycephalic dogs. Results of this study can serve as a basis for CBCT evaluation of dental disorders in brachycephalic dogs.

  4. Proband-only medical exome sequencing as a cost-effective first-tier genetic diagnostic test for patients without prior molecular tests and clinical diagnosis in a developing country: the China experience.

    PubMed

    Hu, Xuyun; Li, Niu; Xu, Yufei; Li, Guoqiang; Yu, Tingting; Yao, Ru-En; Fu, Lijun; Wang, Jiwen; Yin, Lei; Yin, Yong; Wang, Ying; Jin, Xingming; Wang, Xiumin; Wang, Jian; Shen, Yiping

    2017-11-02

    PurposeTo evaluate the performance of proband-only medical exome sequencing (POMES) as a cost-effective first-tier diagnostic test for pediatric patients with unselected conditions.MethodsA total of 1,323 patients were tested by POMES, which targeted 2,742 known disease-causing genes. Clinical relevant variants were Sanger-confirmed in probands and parents. We assessed the diagnostic validity and clinical utility of POMES by means of a survey questionnaire.ResultsPOMES, ordered by 136 physicians, identified 512 pathogenic or likely pathogenic variants associated with over 200 conditions. The overall diagnostic rate was 28.8%, ranging from 10% in neonatal intensive care unit patients to over 35% in pediatric intensive care unit patients. The test results had an impact on the management of the 45.1% of patients for whom there were positive findings. The average turnaround time was 57 days; the cost was $360/case.ConclusionWe adopted a relatively efficient and cost-effective approach in China for the molecular diagnosis of pediatric patients with suspected genetic conditions. While training for clinical geneticists and other specialists is lagging behind in China POMES is serving as a diagnostic equalizer for patients who do not normally receive extensive clinical evaluation and clinical diagnosis prior to testing. This Chinese experience should be applicable to other developing countries that are lacking clinical, financial, and personnel resources.GENETICS in MEDICINE advance online publication, 2 November 2017; doi:10.1038/gim.2017.195.

  5. Evidence report: Genetic and metabolic testing on children with global developmental delay: report of the Quality Standards Subcommittee of the American Academy of Neurology and the Practice Committee of the Child Neurology Society.

    PubMed

    Michelson, D J; Shevell, M I; Sherr, E H; Moeschler, J B; Gropman, A L; Ashwal, S

    2011-10-25

    To systematically review the evidence concerning the diagnostic yield of genetic and metabolic evaluation of children with global developmental delay or intellectual disability (GDD/ID). Relevant literature was reviewed, abstracted, and classified according to the 4-tiered American Academy of Neurology classification of evidence scheme. In patients with GDD/ID, microarray testing is diagnostic on average in 7.8% (Class III), G-banded karyotyping is abnormal in at least 4% (Class II and III), and subtelomeric fluorescence in situ hybridization is positive in 3.5% (Class I, II, and III). Testing for X-linked ID genes has a yield of up to 42% in males with an appropriate family history (Class III). FMR1 testing shows full expansion in at least 2% of patients with mild to moderate GDD/ID (Class II and III), and MeCP2 testing is diagnostic in 1.5% of females with moderate to severe GDD/ID (Class III). Tests for metabolic disorders have a yield of up to 5%, and tests for congenital disorders of glycosylation and cerebral creatine disorders have yields of up to 2.8% (Class III). Several genetic and metabolic screening tests have been shown to have a better than 1% diagnostic yield in selected populations of children with GDD/ID. These values should be among the many factors considered in planning the laboratory evaluation of such children.

  6. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    PubMed

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  7. [Implication of inverse-probability weighting method in the evaluation of diagnostic test with verification bias].

    PubMed

    Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin

    2014-03-01

    To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.

  8. Convergent and diagnostic validity of STAVUX, a word and pseudoword spelling test for adults.

    PubMed

    Östberg, Per; Backlund, Charlotte; Lindström, Emma

    2016-10-01

    Few comprehensive spelling tests are available in Swedish, and none have been validated in adults with reading and writing disorders. The recently developed STAVUX test includes word and pseudoword spelling subtests with high internal consistency and adult norms stratified by education. This study evaluated the convergent and diagnostic validity of STAVUX in adults with dyslexia. Forty-six adults, 23 with dyslexia and 23 controls, took STAVUX together with a standard word-decoding test and a self-rated measure of spelling skills. STAVUX subtest scores showed moderate to strong correlations with word-decoding scores and predicted self-rated spelling skills. Word and pseudoword subtest scores both predicted dyslexia status. Receiver-operating characteristic (ROC) analysis showed excellent diagnostic discriminability. Sensitivity was 91% and specificity 96%. In conclusion, the results of this study support the convergent and diagnostic validity of STAVUX.

  9. Reduced-cost Chlamydia trachomatis-specific multiplex real-time PCR diagnostic assay evaluated for ocular swabs and use by trachoma research programmes.

    PubMed

    Butcher, Robert; Houghton, Jo; Derrick, Tamsyn; Ramadhani, Athumani; Herrera, Beatriz; Last, Anna R; Massae, Patrick A; Burton, Matthew J; Holland, Martin J; Roberts, Chrissy H

    2017-08-01

    Trachoma, caused by the intracellular bacterium Chlamydia trachomatis (Ct), is the leading infectious cause of preventable blindness. Many commercial platforms are available that provide highly sensitive and specific detection of Ct DNA. However, the majority of these commercial platforms are inaccessible for population-level surveys in resource-limited settings typical to trachoma control programmes. We developed two low-cost quantitative PCR (qPCR) tests for Ct using readily available reagents on standard real-time thermocyclers. Each multiplex qPCR test targets one genomic and one plasmid Ct target in addition to an endogenous positive control for Homo sapiens DNA. The quantitative performance of the qPCR assays in clinical samples was determined by comparison to a previously evaluated droplet digital PCR (ddPCR) test. The diagnostic performance of the qPCR assays were evaluated against a commercial assay (artus C. trachomatis Plus RG PCR, Qiagen) using molecular diagnostics quality control standards and clinical samples. We examined the yield of Ct DNA prepared from five different DNA extraction kits and a cold chain-free dry-sample preservation method using swabs spiked with fixed concentrations of human and Ct DNA. The qPCR assay was highly reproducible (Ct plasmid and genomic targets mean total coefficients of variance 41.5% and 48.3%, respectively). The assay detected 8/8 core specimens upon testing of a quality control panel and performed well in comparison to commercially marketed comparator test (sensitivity and specificity>90%). Optimal extraction and sample preservation methods for research applications were identified. We describe a pipeline from collection to diagnosis providing the most efficient sample preservation and extraction with significant per test cost savings over a commercial qPCR diagnostic assay. The assay and its evaluation should allow control programs wishing to conduct independent research within the context of trachoma control, access to an affordable test with defined performance characteristics. Copyright © 2017. Published by Elsevier B.V.

  10. Urinary biomarkers for the non-invasive diagnosis of endometriosis.

    PubMed

    Liu, Emily; Nisenblat, Vicki; Farquhar, Cindy; Fraser, Ian; Bossuyt, Patrick M M; Johnson, Neil; Hull, M Louise

    2015-12-23

    About 10% of reproductive-aged women suffer from endometriosis which is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy is the 'gold standard' diagnostic test for endometriosis, but it is expensive and carries surgical risks. Currently, there are no simple non-invasive or minimally-invasive tests available in clinical practice that accurately diagnoses endometriosis. 1. To provide summary estimates of the diagnostic accuracy of urinary biomarkers for the diagnosis of pelvic endometriosis compared to surgical diagnosis as a reference standard.2. To assess the diagnostic utility of biomarkers that could differentiate ovarian endometrioma from other ovarian masses.Urinary biomarkers were evaluated as replacement tests for surgical diagnosis and as triage tests to inform decisions to undertake surgery for endometriosis. The searches were not restricted to particular study design, language or publication dates. We searched the following databases to 20 April - 31 July 2015: CENTRAL, MEDLINE, EMBASE, CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP and ClinicalTrials.gov (trial register). MEDION, DARE, and PubMed were also searched to identify reviews and guidelines as reference sources of potentially relevant studies. Recently published papers not yet indexed in the major databases were also sought. The search strategy incorporated words in the title, abstract, text words across the record and the medical subject headings (MeSH) and was modified for each database. Published peer-reviewed, randomised controlled or cross-sectional studies of any size were considered, which included prospectively collected samples from any population of reproductive-aged women suspected of having one or more of the following target conditions: ovarian, peritoneal or deep infiltrating endometriosis (DIE). We included studies comparing the diagnostic test accuracy of one or more urinary biomarkers with surgical visualisation of endometriotic lesions. Two authors independently collected and performed a quality assessment of the data from each study. For each diagnostic test, the data were classified as positive or negative for the surgical detection of endometriosis and sensitivity and specificity estimates were calculated. If two or more tests were evaluated in the same cohort, each was considered as a separate data set. The bivariate model was used to obtain pooled estimates of sensitivity and specificity whenever sufficient data sets were available. The predetermined criteria for a clinically useful urine test to replace diagnostic surgery was one with a sensitivity of 94% and a specificity of 79% to detect endometriosis. The criteria for triage tests were set at sensitivity of equal or greater than 95% and specificity of equal or greater than 50%, which in case of negative result rules out the diagnosis (SnOUT test) or sensitivity of equal or greater than 50% with specificity of equal or greater than 95%, which in case of positive result rules the diagnosis in (SpIN test). We included eight studies involving 646 participants, most of which were of poor methodological quality. The urinary biomarkers were evaluated either in a specific phase of menstrual cycle or irrespective of the cycle phase. Five studies evaluated the diagnostic performance of four urinary biomarkers for endometriosis, including three biomarkers distinguishing women with and without endometriosis (enolase 1 (NNE); vitamin D binding protein (VDBP); and urinary peptide profiling); and one biomarker (cytokeratin 19 (CK 19)) showing no significant difference between the two groups. All of these biomarkers were assessed in small individual studies and could not be statistically evaluated in a meaningful way. None of the biomarkers met the criteria for a replacement test or a triage test. Three studies evaluated three biomarkers that did not differentiate women with endometriosis from disease-free controls. There was insufficient evidence to recommend any urinary biomarker for use as a replacement or triage test in clinical practice for the diagnosis of endometriosis. Several urinary biomarkers may have diagnostic potential, but require further evaluation before being introduced into routine clinical practice. Laparoscopy remains the gold standard for the diagnosis of endometriosis, and diagnosis of endometriosis using urinary biomarkers should only be undertaken in a research setting.

  11. Implementation of an Integrated On-Board Aircraft Engine Diagnostic Architecture

    NASA Technical Reports Server (NTRS)

    Armstrong, Jeffrey B.; Simon, Donald L.

    2012-01-01

    An on-board diagnostic architecture for aircraft turbofan engine performance trending, parameter estimation, and gas-path fault detection and isolation has been developed and evaluated in a simulation environment. The architecture incorporates two independent models: a realtime self-tuning performance model providing parameter estimates and a performance baseline model for diagnostic purposes reflecting long-term engine degradation trends. This architecture was evaluated using flight profiles generated from a nonlinear model with realistic fleet engine health degradation distributions and sensor noise. The architecture was found to produce acceptable estimates of engine health and unmeasured parameters, and the integrated diagnostic algorithms were able to perform correct fault isolation in approximately 70 percent of the tested cases

  12. Evaluation of case management of uncomplicated malaria in Haiti: a national health facility survey, 2012.

    PubMed

    Landman, Keren Z; Jean, Samuel E; Existe, Alexandre; Akom, Eniko E; Chang, Michelle A; Lemoine, Jean Frantz; Mace, Kimberly E

    2015-10-09

    Malaria is a public health concern in Haiti, although there are limited data on its burden and case management. National malaria guidelines updated in 2012 recommend treatment with chloroquine and primaquine. In December 2012, a nationally-representative cross-sectional survey of health facilities (HFs) was conducted to determine malaria prevalence among febrile outpatients and malaria case management quality at baseline before scale-up of diagnostics and case management training. Among all 833 HFs nationwide, 30 were selected randomly, in proportion to total HFs per region, for 2-day evaluations. Survey teams inventoried HF material and human resources. Outpatients of all ages were screened for temperature >37.5 °C or history of fever; those without severe symptoms were consented and enrolled. Providers evaluated and treated enrolled patients according to HF standards; the survey teams documented provider-ordered diagnostic tests and treatment decisions. Facility-based test results [microscopy and malaria rapid diagnostic tests (RDTs)] were collected from HF laboratories. Blood smears for gold-standard microscopy, and dried blood spots for polymerase chain reaction (PCR) were obtained. Malaria diagnostic capacity, defined as completing a test for an enrolled patient or having adequate resources for RDTs or microscopy, was present in 11 (37 %) HFs. Among 459 outpatients screened, 257 (56 %) were febrile, of which 193 (75 %) were eligible, and 153 (80 %) were enrolled. Among 39 patients with facility-level malaria test results available on the survey day, 11 (28 %) were positive, of whom 6 (55 %) were treated with an anti-malarial. Twenty-seven (95 %) of the 28 patients testing negative were not treated with an anti-malarial. Of 114 patients without test results available, 35 (31 %) were presumptively treated for malaria. Altogether, 42 patients were treated with an anti-malarial, one (2 %) according to Haiti's 2012 guidelines. Of 140 gold-standard smears, none were positive, although one patient tested positive by PCR, a more sensitive technique. The national prevalence of malaria among febrile outpatients is estimated to be 0.5 % (95 % confidence interval 0-1.7 %). Malaria is an uncommon cause of fever in Haitian outpatients, and limited, often inaccurate, diagnostic capacity at baseline contributes to over diagnosis. Scale-up of diagnostics and training on new guidelines should improve malaria diagnosis and treatment in Haiti.

  13. Diagnostics for the detection and evaluation of laser induced damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheehan, L.; Kozlowski, M.; Rainer, F.

    1995-12-31

    The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less

  14. Diagnostics for the detection and evaluation of laser induced damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sheehan, L.; Kozlowski, M.; Rainer, F.

    1995-01-03

    The Laser Damage and Conditioning Group at LLNL is evaluating diagnostics which will help make damage testing more efficient and reduce the risk of damage during laser conditioning. The work to date has focused on photoacoustic and scattered light measurements on 1064-nm wavelength HfO{sub 2}/SiO{sub 2} multilayer mirror and polarizer coatings. Both the acoustic and scatter diagnostics have resolved 10 {mu}m diameter damage points in these coatings. Using a scanning stage, the scatter diagnostic can map both intrinsic and laser-induced scatter. Damage threshold measurements obtained using scatter diagnostics compare within experimental error with those measured using 100x Nomarski microscopy. Scattermore » signals measured during laser conditioning can be used to detect damage related to nodular defects.« less

  15. Value of physical tests in diagnosing cervical radiculopathy: a systematic review.

    PubMed

    Thoomes, Erik J; van Geest, Sarita; van der Windt, Danielle A; Falla, Deborah; Verhagen, Arianne P; Koes, Bart W; Thoomes-de Graaf, Marloes; Kuijper, Barbara; Scholten-Peeters, Wendy G M; Vleggeert-Lankamp, Carmen L

    2018-01-01

    In clinical practice, the diagnosis of cervical radiculopathy is based on information from the patient's history, physical examination, and diagnostic imaging. Various physical tests may be performed, but their diagnostic accuracy is unknown. This study aimed to summarize and update the evidence on diagnostic performance of tests carried out during a physical examination for the diagnosis of cervical radiculopathy. A review of the accuracy of diagnostic tests was carried out. The study sample comprised diagnostic studies comparing results of tests performed during a physical examination in diagnosing cervical radiculopathy with a reference standard of imaging or surgical findings. Sensitivity, specificity, likelihood ratios are presented, together with pooled results for sensitivity and specificity. A literature search up to March 2016 was performed in CENTRAL, PubMed (MEDLINE), Embase, CINAHL, Web of Science, and Google Scholar. The methodological quality of studies was assessed using the QUADAS-2. Five diagnostic accuracy studies were identified. Only Spurling's test was evaluated in more than one study, showing high specificity ranging from 0.89 to 1.00 (95% confidence interval [CI]: 0.59-1.00); sensitivity varied from 0.38 to 0.97 (95% CI: 0.21-0.99). No studies were found that assessed the diagnostic accuracy of widely used neurological tests such as key muscle strength, tendon reflexes, and sensory impairments. There is limited evidence for accuracy of physical examination tests for the diagnosis of cervical radiculopathy. When consistent with patient history, clinicians may use a combination of Spurling's, axial traction, and an Arm Squeeze test to increase the likelihood of a cervical radiculopathy, whereas a combined results of four negative neurodynamics tests and an Arm Squeeze test could be used to rule out the disorder. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. A portable hardware-in-the-loop (HIL) device for automotive diagnostic control systems.

    PubMed

    Palladino, A; Fiengo, G; Lanzo, D

    2012-01-01

    In-vehicle driving tests for evaluating the performance and diagnostic functionalities of engine control systems are often time consuming, expensive, and not reproducible. Using a hardware-in-the-loop (HIL) simulation approach, new control strategies and diagnostic functions on a controller area network (CAN) line can be easily tested in real time, in order to reduce the effort and the cost of the testing phase. Nowadays, spark ignition engines are controlled by an electronic control unit (ECU) with a large number of embedded sensors and actuators. In order to meet the rising demand of lower emissions and fuel consumption, an increasing number of control functions are added into such a unit. This work aims at presenting a portable electronic environment system, suited for HIL simulations, in order to test the engine control software and the diagnostic functionality on a CAN line, respectively, through non-regression and diagnostic tests. The performances of the proposed electronic device, called a micro hardware-in-the-loop system, are presented through the testing of the engine management system software of a 1.6 l Fiat gasoline engine with variable valve actuation for the ECU development version. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Develop Advanced Nonlinear Signal Analysis Topographical Mapping System

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1997-01-01

    During the development of the SSME, a hierarchy of advanced signal analysis techniques for mechanical signature analysis has been developed by NASA and AI Signal Research Inc. (ASRI) to improve the safety and reliability for Space Shuttle operations. These techniques can process and identify intelligent information hidden in a measured signal which is often unidentifiable using conventional signal analysis methods. Currently, due to the highly interactive processing requirements and the volume of dynamic data involved, detailed diagnostic analysis is being performed manually which requires immense man-hours with extensive human interface. To overcome this manual process, NASA implemented this program to develop an Advanced nonlinear signal Analysis Topographical Mapping System (ATMS) to provide automatic/unsupervised engine diagnostic capabilities. The ATMS will utilize a rule-based Clips expert system to supervise a hierarchy of diagnostic signature analysis techniques in the Advanced Signal Analysis Library (ASAL). ASAL will perform automatic signal processing, archiving, and anomaly detection/identification tasks in order to provide an intelligent and fully automated engine diagnostic capability. The ATMS has been successfully developed under this contract. In summary, the program objectives to design, develop, test and conduct performance evaluation for an automated engine diagnostic system have been successfully achieved. Software implementation of the entire ATMS system on MSFC's OISPS computer has been completed. The significance of the ATMS developed under this program is attributed to the fully automated coherence analysis capability for anomaly detection and identification which can greatly enhance the power and reliability of engine diagnostic evaluation. The results have demonstrated that ATMS can significantly save time and man-hours in performing engine test/flight data analysis and performance evaluation of large volumes of dynamic test data.

  18. Diagnostic Lumbar Puncture

    PubMed Central

    Doherty, Carolynne M; Forbes, Raeburn B

    2014-01-01

    Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138

  19. Magnetic resonance defecography versus videodefecography in the study of obstructed defecation syndrome: Is videodefecography still the test of choice after 50 years?

    PubMed

    Martín-Martín, G P; García-Armengol, J; Roig-Vila, J V; Espí-Macías, A; Martínez-Sanjuán, V; Mínguez-Pérez, M; Lorenzo-Liñán, M Á; Mulas-Fernández, C; González-Argenté, F X

    2017-10-01

    The aim of the present study was to evaluate the diagnostic accuracy of magnetic resonance (MR) defecography and compare it with videodefecography in the evaluation of obstructed defecation syndrome. This was a prospective cohort test accuracy study conducted at one major tertiary referral center on patients with a diagnosis of obstructed defecation syndrome who were referred to the colorectal surgery clinic in a consecutive series from 2009 to 2012. All patients underwent a clinical examination, videodefecography, and MR defecography in the supine position. We analyzed diagnostic accuracy for MR defecography and performed an agreement analysis using Cohen's kappa index (κ) for each diagnostic imaging examination performed with videodefecography and MR defecography. We included 40 patients with Rome III diagnostic criteria of obstructed defecation syndrome. The degree of agreement between the two tests was as follows: almost perfect for anismus (κ = 0.88) and rectal prolapse (κ = 0.83), substantial for enterocele (κ = 0.80) and rectocele grade III (κ = 0.65), moderate for intussusception (κ = 0.50) and rectocele grade II (κ = 0.49), and slight for rectocele grade I (κ = 0.30) and excessive perineal descent (κ = 0.22). Eighteen cystoceles and 11 colpoceles were diagnosed only by MR defecography. Most patients (54%) stated that videodefecography was the more uncomfortable test. MR defecography could become the imaging test of choice for evaluating obstructed defecation syndrome.

  20. Diagnostic value of isoproterenol testing in arrhythmogenic right ventricular cardiomyopathy.

    PubMed

    Denis, Arnaud; Sacher, Frédéric; Derval, Nicolas; Lim, Han S; Cochet, Hubert; Shah, Ashok J; Daly, Matthew; Pillois, Xavier; Ramoul, Khaled; Komatsu, Yuki; Zemmoura, Adlane; Amraoui, Sana; Ritter, Philippe; Ploux, Sylvain; Bordachar, Pierre; Hocini, Mélèze; Jaïs, Pierre; Haïssaguerre, Michel

    2014-08-01

    Although the Task Force Criteria for arrhythmogenic right ventricular cardiomyopathy (ARVC) have recently been updated, the diagnosis remains challenging in the early stages. The aim of this study was to evaluate the diagnostic value of β-adrenergic stimulation in ARVC. We evaluated 412 consecutive patients (213 men, age 41.5±16 years) referred for premature ventricular contractions evaluation or suspected ARVC. Isoproterenol testing was performed with continuous infusion of isoproterenol (45 μg/min) for 3 minutes. It was considered positive if there were either (1) polymorphic premature ventricular contractions with ≥1 couplet or (2) sustained or nonsustained ventricular tachycardia with left bundle branch block excluding right ventricular outflow tract ventricular tachycardia. ARVC was diagnosed in 35 patients at initial evaluation (23 men, aged 42±15 years). Isoproterenol testing was positive in 32 of 35 (91.4%) patients with ARVC and in 42 of 377 (11.1%) patients without ARVC (P<0.0001). Sensitivity, specificity, positive, and negative predictive values of isoproterenol testing to diagnose ARVC were 91.4%, 88.9%, 43.2%, and 99.1%, respectively. During a mean follow-up period of 5.6±4.4 years, 6 additional patients met diagnostic criteria for ARVC. Importantly, initial isoproterenol testing was positive in 6 of 6 (100%) of these patients. Survival free from ARVC diagnosis was significantly lower in the positive isoproterenol group than in the negative isoproterenol group (P<0.0001, exact log-rank test). Ventricular arrhythmogenicity during isoproterenol testing is highly sensitive (sensitivity, 91.4%) for the diagnosis of ARVC, particularly in its early stages. © 2014 American Heart Association, Inc.

  1. Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia.

    PubMed

    Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D

    2017-11-01

    Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.

  2. BASIC BIOCHEMICAL AND CLINICAL ASPECTS OF NONINVASIVE TESTS HELIC.

    PubMed

    Dmitrienko, M A; Dmitrienko, V S; Kornienko, E A; Parolova, N I; Colomina, E O; Aronov, E B

    Biochemical process that lay in the core of non-invasive detection of Helico ho cter pylod with the help of HELIC Ammonia breath test, manufactured by AMA Co Ltd., St.Petersburg, is shown. Patents from various countries, describing ammonia as H.pyiori diagnostic marker, are reviewed. Approaches for evaluation of efficacy of the test-system are analyzed, validation and verification data is provided. High diagnostic characteristics are confirmed by the results of comparative studies on patients of different age groups, reaching 97% sensitivity and 96% specificity.

  3. Evaluation of phenotypic detection methods for metallo-β-lactamases (MBLs) in clinical isolates of Pseudomonas aeruginosa.

    PubMed

    Peter, S; Lacher, A; Marschal, M; Hölzl, F; Buhl, M; Autenrieth, I; Kaase, M; Willmann, M

    2014-07-01

    Metallo-beta-lactamase (MBL) production in Pseudomonas aeruginosa is a growing issue across the globe. Fast and reliable diagnostic tools are needed for appropriate implementation of infection control measures. In this study we evaluated the performance of three commercial combined disk tests, two EDTA based in-house combined disk tests and the Carba NP test in comparison to molecular detection of MBL genes on 133 meropenem non-susceptible non-duplicate P. aeruginosa clinical isolates. The meropenem/DPA based commercial KPC + MBL-confirm ID kit (Rosco Diagnostica, Denmark) and the MASTDISCS™ ID carbapenemase (Enterobacteriaceae) detection disc set (MAST Diagnostics, UK) showed sensitivities of 31.1 % and 28.8 % and specificities of 69.3 % and 79.6 %, respectively. The total MBL confirm kit (Rosco Diagnostica, Denmark) contains imipenem/DPA and imipenem/EDTA combination disks. Evaluation of the single disk combinations revealed 84.4 % sensitivity and 81.8 % specificity for the imipenem/DPA assay and 86.7 % sensitivity and 51.1 % specificity for the imipenem/EDTA test. Applying both tests simultaneously resulted in a slightly higher sensitivity of 88.9 % but a lower specificity of 48.9 % when compared to the single tests alone. The Carba NP test showed 93.3 % sensitivity and 96.6 % specificity. All phenotypic combined disk tests lacked either sensitivity or specificity for the detection of MBL in P. aeruginosa. The Carba NP test showed excellent test properties, but suffers from drawbacks in handling and high costs. The optimal diagnostic approach needs to be chosen depending on the epidemiological situation, laboratory resources and availability of molecular confirmation tests.

  4. Improving the Efficiency and Quality of the Value Assessment Process for Companion Diagnostic Tests: The Companion test Assessment Tool (CAT).

    PubMed

    Canestaro, William J; Pritchard, Daryl E; Garrison, Louis P; Dubois, Robert; Veenstra, David L

    2015-08-01

    Companion diagnostic tests (CDTs) have emerged as a vital technology in the effective use of an increasing number of targeted drug therapies. Although CDTs can offer a multitude of potential benefits, assessing their value within a health technology appraisal process can be challenging because of a complex array of factors that influence clinical and economic outcomes. To develop a user-friendly tool to assist managed care and other health care decision makers in screening companion tests and determining whether an intensive technology review is necessary and, if so, where the review should be focused to improve efficiency. First, we conducted a systematic literature review of CDT cost-effectiveness studies to identify value drivers. Second, we conducted key informant interviews with a diverse group of stakeholders to elicit feedback and solicit any additional value drivers and identify desirable attributes for an evidence review tool. A draft tool was developed based on this information that captured value drivers, usability features, and had a particular focus on practical use by nonexperts. Finally, the tool was pilot tested with test developers and managed care evidence evaluators to assess face-validity and usability. The tool was also evaluated using several diverse examples of existing companion diagnostics and refined accordingly. We identified 65 cost-effectiveness studies of companion diagnostic technologies. The following factors were most commonly identified as value drivers from our literature review: clinical validity of testing; efficacy, safety, and cost of baseline and alternative treatments; cost and mortality of health states; and biomarker prevalence and testing cost. Stakeholders identified the following additional factors that they believed influenced the overall value of a companion test: regulatory status, actionability, utility, and market penetration. These factors were used to maximize the efficiency of the evidence review process. Stakeholders also stated that a tool should be easy to use and time efficient. Cognitive interviews with stakeholders led to minor changes in the draft tool to improve usability and relevance. The final tool consisted of 4 sections: (1) eligibility for review (2 questions), (2) prioritization of review (3 questions), (3) clinical review (3 questions), and (4) economic review (5 questions). Although the evaluation of CDTs can be challenging because of limited evidence and the added complexity of incorporating a diagnostic test into drug treatment decisions, using a pragmatic tool to identify tests that do not need extensive evaluation may improve the efficiency and effectiveness of CDT value assessments.

  5. Diagnostic tests and algorithms used in the investigation of haematuria: systematic reviews and economic evaluation.

    PubMed

    Rodgers, M; Nixon, J; Hempel, S; Aho, T; Kelly, J; Neal, D; Duffy, S; Ritchie, G; Kleijnen, J; Westwood, M

    2006-06-01

    To determine the most effective diagnostic strategy for the investigation of microscopic and macroscopic haematuria in adults. Electronic databases from inception to October 2003, updated in August 2004. A systematic review was undertaken according to published guidelines. Decision analytic modelling was undertaken, based on the findings of the review, expert opinion and additional information from the literature, to assess the relative cost-effectiveness of plausible alternative tests that are part of diagnostic algorithms for haematuria. A total of 118 studies met the inclusion criteria. No studies that evaluated the effectiveness of diagnostic algorithms for haematuria or the effectiveness of screening for haematuria or investigating its underlying cause were identified. Eighteen out of 19 identified studies evaluated dipstick tests and data from these suggested that these are moderately useful in establishing the presence of, but cannot be used to rule out, haematuria. Six studies using haematuria as a test for the presence of a disease indicated that the detection of microhaematuria cannot alone be considered a useful test either to rule in or rule out the presence of a significant underlying pathology (urinary calculi or bladder cancer). Forty-eight of 80 studies addressed methods to localise the source of bleeding (renal or lower urinary tract). The methods and thresholds described in these studies varied greatly, precluding any estimate of a 'best performance' threshold that could be applied across patient groups. However, studies of red blood cell morphology that used a cut-off value of 80% dysmorphic cells for glomerular disease reported consistently high specificities (potentially useful in ruling in a renal cause for haematuria). The reported sensitivities were generally low. Twenty-eight studies included data on the accuracy of laboratory tests (tumour markers, cytology) for the diagnosis of bladder cancer. The majority of tumour marker studies evaluated nuclear matrix protein 22 or bladder tumour antigen. The sensitivity and specificity ranges suggested that neither of these would be useful either for diagnosing bladder cancer or for ruling out patients for further investigation (cystoscopy). However, the evidence remains sparse and the diagnostic accuracy estimates varied widely between studies. Fifteen studies evaluating urine cytology as a test for urinary tract malignancies were heterogeneous and poorly reported. The calculated specificity values were generally high, suggesting some possible utility in confirming malignancy. However, the evidence suggests that urine cytology has no application in ruling out malignancy or excluding patients from further investigation. Fifteen studies evaluated imaging techniques [computed tomography (CT), intravenous urography (IVU) or ultrasound scanning (US)] to detect the underlying cause of haematuria. The target condition and the reference standard varied greatly between these studies. The diagnostic accuracy data for several individual studies appeared promising but meaningful comparison of the available imaging technologies was impossible. Eight studies met the inclusion criteria but addressed different parts of the diagnostic chain (e.g. screening programmes, laboratory investigations, full urological work-up). No single study addressed the complete diagnostic process. The review also highlighted a number of methodological limitations of these studies, including their lack of generalisability to the UK context. Separate decision analytic models were therefore developed to progress estimation of the optimal strategy for the diagnostic management of haematuria. The economic model for the detection of microhaematuria found that immediate microscopy following a positive dipstick test would improve diagnostic efficiency as it eliminates the high number of false positives produced by dipstick testing. Strategies that use routine microscopy may be associated with high numbers of false results, but evidence was lacking regarding the accuracy of routine microscopy and estimates were adopted for the model. The model for imaging the upper urinary tract showed that US detects more tumours than IVU at one-third of the cost, and is also associated with fewer false results. For any cause of haematuria, CT was shown to have a mean incremental cost-effectiveness ratio of pounds sterling 9939 in comparison with the next best option, US. When US is followed up with CT for negative results with persistent haematuria, it dominates the initial use of CT alone, with a saving of pounds sterling 235,000 for the evaluation of 1000 patients. The model for investigation of the lower urinary tract showed that for low-risk patients the use of immediate cystoscopy could be avoided if cystoscopy were used for follow-up patients with a negative initial test using tumour markers and/or cytology, resulting in a saving of pounds sterling 483,000 for the evaluation of 1000 patients. The clinical and economic impact on delayed detection of both upper and lower urinary tract tumours through the use of follow-up testing should be evaluated in future studies. There are insufficient data currently available to derive an evidence-based algorithm of the diagnostic pathway for haematuria. A hypothetical algorithm based on the opinion and practice of clinical experts in the review team, other published algorithms and the results of economic modelling is presented in this report. This algorithm is presented, for comparative purposes, alongside current US and UK guidelines. The ideas contained in these algorithms and the specific questions outlined should form the basis of future research. Quality assessment of the diagnostic accuracy studies included in this review highlighted several areas of deficiency.

  6. Tapered Roller Bearing Damage Detection Using Decision Fusion Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Kreider, Gary; Fichter, Thomas

    2006-01-01

    A diagnostic tool was developed for detecting fatigue damage of tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. A diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests conducted using health monitoring hardware. Failure progression tests were performed with tapered roller bearings under simulated engine load conditions. Tests were performed on one healthy bearing and three pre-damaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor and three accelerometers were monitored and recorded for the occurrence of bearing failure. The bearing was removed and inspected periodically for damage progression throughout testing. Using data fusion techniques, two different monitoring technologies, oil debris analysis and vibration, were integrated into a health monitoring system for detecting bearing surface fatigue pitting damage. The data fusion diagnostic tool was evaluated during bearing failure progression tests under simulated engine load conditions. This integrated system showed improved detection of fatigue damage and health assessment of the tapered roller bearings as compared to using individual health monitoring technologies.

  7. Hyperventilation-induced nystagmus in vestibular schwannoma and unilateral sensorineural hearing loss.

    PubMed

    Mandalà, Marco; Giannuzzi, Annalisa; Astore, Serena; Trabalzini, Franco; Nuti, Daniele

    2013-07-01

    We evaluated the incidence and characteristics of hyperventilation-induced nystagmus (HVN) in 49 patients with gadolinium-enhanced magnetic resonance imaging evidence of vestibular schwannoma and 53 patients with idiopathic unilateral sensorineural hearing loss and normal radiological findings. The sensitivity and specificity of the hyperventilation test were compared with other audio-vestibular diagnostic tests (bedside examination of eye movements, caloric test, auditory brainstem responses) in the two groups of patients. The hyperventilation test scored the highest diagnostic efficiency (sensitivity 65.3 %; specificity 98.1 %) of the four tests in the differential diagnosis of vestibular schwannoma and idiopathic unilateral sensorineural hearing loss. Small tumors with a normal caloric response or caloric paresis were associated with ipsilateral HVN and larger tumors and severe caloric deficits with contralateral HVN. These results confirm that the hyperventilation test is a useful diagnostic test for predicting vestibular schwannoma in patients with unilateral sensorineural hearing loss.

  8. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  9. Clinical Application of Genome and Exome Sequencing as a Diagnostic Tool for Pediatric Patients: a Scoping Review of the Literature.

    PubMed

    Smith, Hadley Stevens; Swint, J Michael; Lalani, Seema R; Yamal, Jose-Miguel; de Oliveira Otto, Marcia C; Castellanos, Stephan; Taylor, Amy; Lee, Brendan H; Russell, Heidi V

    2018-05-14

    Availability of clinical genomic sequencing (CGS) has generated questions about the value of genome and exome sequencing as a diagnostic tool. Analysis of reported CGS application can inform uptake and direct further research. This scoping literature review aims to synthesize evidence on the clinical and economic impact of CGS. PubMed, Embase, and Cochrane were searched for peer-reviewed articles published between 2009 and 2017 on diagnostic CGS for infant and pediatric patients. Articles were classified according to sample size and whether economic evaluation was a primary research objective. Data on patient characteristics, clinical setting, and outcomes were extracted and narratively synthesized. Of 171 included articles, 131 were case reports, 40 were aggregate analyses, and 4 had a primary economic evaluation aim. Diagnostic yield was the only consistently reported outcome. Median diagnostic yield in aggregate analyses was 33.2% but varied by broad clinical categories and test type. Reported CGS use has rapidly increased and spans diverse clinical settings and patient phenotypes. Economic evaluations support the cost-saving potential of diagnostic CGS. Multidisciplinary implementation research, including more robust outcome measurement and economic evaluation, is needed to demonstrate clinical utility and cost-effectiveness of CGS.

  10. External quality assessment studies for laboratory performance of molecular and serological diagnosis of Chikungunya virus infection.

    PubMed

    Jacobsen, Sonja; Patel, Pranav; Schmidt-Chanasit, Jonas; Leparc-Goffart, Isabelle; Teichmann, Anette; Zeller, Herve; Niedrig, Matthias

    2016-03-01

    Since the re-emergence of Chikungunya virus (CHIKV) in Reunion in 2005 and the recent outbreak in the Caribbean islands with an expansion to the Americas the CHIK diagnostic became very important. We evaluate the performance of laboratories regarding molecular and serological diagnostic of CHIK worldwide. A panel of 12 samples for molecular and 13 samples for serology were provided to 60 laboratories in 40 countries for evaluating the sensitivity and specificity of molecular and serology testing. The panel for molecular diagnostic testing was analysed by 56 laboratories returning 60 data sets of results whereas the 56 and 60 data sets were returned for IgG and IgM diagnostic from the participating laboratories. Twenty-three from 60 data sets performed optimal, 7 acceptable and 30 sets of results require improvement. From 50 data sets only one laboratory shows an optimal performance for IgM detection, followed by 9 data sets with acceptable and the rest need for improvement. From 46 IgG serology data sets 20 provide an optimal, 2 an acceptable and 24 require improvement performance. The evaluation of some of the diagnostic performances allows linking the quality of results to the in-house methods or commercial assays used. The external quality assurance for CHIK diagnostics provides a good overview on the laboratory performance regarding sensitivity and specificity for the molecular and serology diagnostic required for the quick and reliable analysis of suspected CHIK patients. Nearly half of the laboratories have to improve their diagnostic profile to achieve a better performance. Copyright © 2016 Z. Published by Elsevier B.V. All rights reserved.

  11. Assessment of Diverse Biological Indicators in Gulf War Illness: Are They Replicable Are They Related

    DTIC Science & Technology

    2016-04-01

    compared to 50 healthy veteran controls in a protocol that includes physical and neuropsychological evaluations, neuroimaging (MRI, fMRI, DTI), adrenal...SUBJECT TERMS Gulf War illness, neuroimaging, neuropsychological testing, immune function, hypothalamic-pituitary-adrenal testing 16. SECURITY... neuropsychological evaluations, assessment of hypothalamic-pituitary-adrenal function, standard clinical diagnostic laboratory tests, and research

  12. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    PubMed

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  13. A computational framework for converting textual clinical diagnostic criteria into the quality data model.

    PubMed

    Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian

    2016-10-01

    Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. A hybrid model for combining case-control and cohort studies in systematic reviews of diagnostic tests

    PubMed Central

    Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao

    2014-01-01

    Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179

  15. New method for detection of gastric cancer by hyperspectral imaging: a pilot study

    NASA Astrophysics Data System (ADS)

    Kiyotoki, Shu; Nishikawa, Jun; Okamoto, Takeshi; Hamabe, Kouichi; Saito, Mari; Goto, Atsushi; Fujita, Yusuke; Hamamoto, Yoshihiko; Takeuchi, Yusuke; Satori, Shin; Sakaida, Isao

    2013-02-01

    We developed a new, easy, and objective method to detect gastric cancer using hyperspectral imaging (HSI) technology combining spectroscopy and imaging A total of 16 gastroduodenal tumors removed by endoscopic resection or surgery from 14 patients at Yamaguchi University Hospital, Japan, were recorded using a hyperspectral camera (HSC) equipped with HSI technology Corrected spectral reflectance was obtained from 10 samples of normal mucosa and 10 samples of tumors for each case The 16 cases were divided into eight training cases (160 training samples) and eight test cases (160 test samples) We established a diagnostic algorithm with training samples and evaluated it with test samples Diagnostic capability of the algorithm for each tumor was validated, and enhancement of tumors by image processing using the HSC was evaluated The diagnostic algorithm used the 726-nm wavelength, with a cutoff point established from training samples The sensitivity, specificity, and accuracy rates of the algorithm's diagnostic capability in the test samples were 78.8% (63/80), 92.5% (74/80), and 85.6% (137/160), respectively Tumors in HSC images of 13 (81.3%) cases were well enhanced by image processing Differences in spectral reflectance between tumors and normal mucosa suggested that tumors can be clearly distinguished from background mucosa with HSI technology.

  16. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    PubMed

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  17. Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria

    PubMed Central

    Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.

    2013-01-01

    Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403

  18. The impact of a computerised test of attention and activity (QbTest) on diagnostic decision-making in children and young people with suspected attention deficit hyperactivity disorder: single-blind randomised controlled trial.

    PubMed

    Hollis, Chris; Hall, Charlotte L; Guo, Boliang; James, Marilyn; Boadu, Janet; Groom, Madeleine J; Brown, Nikki; Kaylor-Hughes, Catherine; Moldavsky, Maria; Valentine, Althea Z; Walker, Gemma M; Daley, David; Sayal, Kapil; Morriss, Richard

    2018-04-26

    Diagnosis of attention deficit hyperactivity disorder (ADHD) relies on subjective methods which can lead to diagnostic uncertainty and delay. This trial evaluated the impact of providing a computerised test of attention and activity (QbTest) report on the speed and accuracy of diagnostic decision-making in children with suspected ADHD. Randomised, parallel, single-blind controlled trial in mental health and community paediatric clinics in England. Participants were 6-17 years-old and referred for ADHD diagnostic assessment; all underwent assessment-as-usual, plus QbTest. Participants and their clinician were randomised to either receive the QbTest report immediately (QbOpen group) or the report was withheld (QbBlind group). The primary outcome was number of consultations until a diagnostic decision confirming/excluding ADHD within 6-months from baseline. Health economic cost-effectiveness and cost utility analysis was conducted. Assessing QbTest Utility in ADHD: A Randomised Controlled Trial was registered at ClinicalTrials.gov (https://clinicaltrials.gov/ct2/show/NCT02209116). One hundred and thirty-two participants were randomised to QbOpen group (123 analysed) and 135 to QbBlind group (127 analysed). Clinicians with access to the QbTest report (QbOpen) were more likely to reach a diagnostic decision about ADHD (hazard ratio 1.44, 95% CI 1.04-2.01). At 6-months, 76% of those with a QbTest report had received a diagnostic decision, compared with 50% without. QbTest reduced appointment length by 15% (time ratio 0.85, 95% CI 0.77-0.93), increased clinicians' confidence in their diagnostic decisions (odds ratio 1.77, 95% CI 1.09-2.89) and doubled the likelihood of excluding ADHD. There was no difference in diagnostic accuracy. Health economic analysis showed a position of strict dominance; however, cost savings were small suggesting that the impact of providing the QbTest report within this trial can best be viewed as 'cost neutral'. QbTest may increase the efficiency of ADHD assessment pathway allowing greater patient throughput with clinicians reaching diagnostic decisions faster without compromising diagnostic accuracy. © 2018 The Authors. Journal of Child Psychology and Psychiatry published by John Wiley & Sons Ltd on behalf of Association for Child and Adolescent Mental Health.

  19. Carpal tunnel syndrome: Investigating the sensitivity of initial-diagnosis with electro-diagnostic tests in 600 cases and associated risk factors especially manual milking.

    PubMed

    Tunç, Abdulkadir; Güngen, Belma Doğan

    2017-01-01

    Electro-diagnostic studies are the most reliable methods in diagnosis of carpal tunnel syndrome (CTS). Although there are many risk factors associated with CTS, there are a limited number of studies in the literature indicating that manual milking, which is frequently seen in Turkey, is a risk factor for CTS. The purpose of this study was to evaluate demographic findings of cases referred due to initial diagnosis of CTS as well as aetiological data especially manual milking and to investigate the sensitivity of initial diagnosis of CTS. Six hundred patients, who were referred to our electromyography laboratory due to initial diagnosis of CTS, were included. Demographic findings, duration of complaints, existence of diabetes mellitus, and manual milking histories of all patients were recorded. Sensitivity of initial diagnosis was investigated based on electro-diagnostic test results. According to electro-diagnostic test results, 289 of the patients were diagnosed with CTS (48.17%). 110 (18.3%) of 600 patients had a history of manual milking. In 94 of this group (85.4%), CTS was detected. Statistically significant correlation was found between CTS and age, female gender, duration of complaints, obesity and manual milking. This study confirms that manual milking is an important risk factor for CTS in addition to female gender, age, symptom duration and obesity. The fact that sensitivity of initial diagnosis of CTS was found to be low according to electro-diagnostic test results indicates importance of detailed clinical evaluation.

  20. Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.

    PubMed

    Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu

    2017-09-01

    The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  1. Conversion-Integration of MSFC Nonlinear Signal Diagnostic Analysis Algorithms for Realtime Execution of MSFC's MPP Prototype System

    NASA Technical Reports Server (NTRS)

    Jong, Jen-Yi

    1996-01-01

    NASA's advanced propulsion system Small Scale Magnetic Disturbances/Advanced Technology Development (SSME/ATD) has been undergoing extensive flight certification and developmental testing, which involves large numbers of health monitoring measurements. To enhance engine safety and reliability, detailed analysis and evaluation of the measurement signals are mandatory to assess its dynamic characteristics and operational condition. Efficient and reliable signal detection techniques will reduce the risk of catastrophic system failures and expedite the evaluation of both flight and ground test data, and thereby reduce launch turn-around time. During the development of SSME, ASRI participated in the research and development of several advanced non- linear signal diagnostic methods for health monitoring and failure prediction in turbomachinery components. However, due to the intensive computational requirement associated with such advanced analysis tasks, current SSME dynamic data analysis and diagnostic evaluation is performed off-line following flight or ground test with a typical diagnostic turnaround time of one to two days. The objective of MSFC's MPP Prototype System is to eliminate such 'diagnostic lag time' by achieving signal processing and analysis in real-time. Such an on-line diagnostic system can provide sufficient lead time to initiate corrective action and also to enable efficient scheduling of inspection, maintenance and repair activities. The major objective of this project was to convert and implement a number of advanced nonlinear diagnostic DSP algorithms in a format consistent with that required for integration into the Vanderbilt Multigraph Architecture (MGA) Model Based Programming environment. This effort will allow the real-time execution of these algorithms using the MSFC MPP Prototype System. ASRI has completed the software conversion and integration of a sequence of nonlinear signal analysis techniques specified in the SOW for real-time execution on MSFC's MPP Prototype. This report documents and summarizes the results of the contract tasks; provides the complete computer source code; including all FORTRAN/C Utilities; and all other utilities/supporting software libraries that are required for operation.

  2. Achievement Testing--A Look at Trends.

    ERIC Educational Resources Information Center

    Bligh, Harold F.

    The strengths and weakness of standardized tests, and trends in achievement testing in the last 15 years are examined. The discussion of achievement tests includes survey, instructional, diagnostic, and basic skills tests, as well as tests used for formative and summative evaluation. Minimum competency tests are not examined in detail. Advantages…

  3. Diagnostic, therapeutic and economic consequences of a positive urinary antigen test for Legionella spp. in patients admitted with community-acquired pneumonia: a 7-year retrospective evaluation.

    PubMed

    Engel, M F; van Manen, L; Hoepelman, A I M; Thijsen, S; Oosterheert, J J

    2013-09-01

    A positive urinary antigen test for Legionella spp. (Legionella urinary antigen test; LUAT) allows an early switch from empiric to targeted treatment (TT) in hospitalised, community-acquired pneumonia (CAP) patients. We aimed to evaluate the diagnostic, therapeutic and economic consequences of this frequently used test 7 years after its implementation. We retrospectively evaluated LUATs performed between 2005 and 2011 in two teaching hospitals. All tests performed in hospitalised CAP patients were used in the economic evaluation and positive tests were included in the treatment evaluation. Data on patient characteristics, admission and outcome were retrieved from the patients' files. The number of days gained by making a rapid aetiological diagnosis, the number of days TT could be provided and their costs were calculated. Of 4485 LUATs, 2504 (56%) were performed for CAP including 55 (1%) positive tests (€1041/positive test). In 26 (60%) of the 43 included positive tests, LUAT was the only test showing Legionella spp. Subsequently, earlier TT was possible in the remaining cases during 209 cumulative admission days (€274/TT day). LUAT led to detection of Legionella spp. 13 days earlier per case (€203/day) as compared with culture/serology alone. Timely LUAT use in accordance with current guidelines allows early detection and treatment of CAP caused by Legionella spp. at considerable expense.

  4. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  5. Accuracy of the radioactive copper incorporation test in the diagnosis of Wilson disease.

    PubMed

    Członkowska, Anna; Rodo, Maria; Wierzchowska-Ciok, Agata; Smolinski, Lukasz; Litwin, Tomasz

    2018-02-08

    In Wilson disease (WD), copper accumulates in the liver and other tissues because of mutations in the ATP7B copper transporter gene. Early and effective anticopper treatment is crucial. However, routine diagnostic methods based on clinical findings, copper metabolism tests, liver biopsies and DNA analyses do not always provide a conclusive diagnosis. The aim was to evaluate radioactive copper incorporation as a diagnostic test. We included cases with a diagnosis of WD supported by radiocopper testing and later, when available, confirmed by DNA analysis. Incorporation of 64 Cu was measured at 2, 24 and 48 hours following intravenous injection. Diagnostic accuracy (area under the receiver operating characteristic curve [AUC]), sensitivity, specificity and predictive value were assessed for 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios and compared with serum measurements of ceruloplasmin, copper, non-ceruloplasmin-bound copper and urinary 24-hours copper excretion. Patients having two pathogenic ATP7B mutations (homozygotes/compound heterozygotes) (n = 74) had significantly lower 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios than heterozygote controls (n = 21) (mean 0.14 and 0.12 vs 0.49 and 0.63, respectively; both P < .001). Of note, 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios had excellent diagnostic accuracy, with AUCs approaching 1, and only 24-hours urinary copper excretion displayed similar positive features. Other copper metabolism tests studied had lower accuracy, specificity and sensitivity. The radioactive copper test had excellent diagnostic accuracy and may be useful in the evaluation of new therapies aimed at restoring ATP7B function. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. Diagnostic-test evaluation of immunoassays for anti-Toxoplasma gondii IgG antibodies in a random sample of Mexican population.

    PubMed

    Caballero-Ortega, Heriberto; Castillo-Cruz, Rocío; Murieta, Sandra; Ortíz-Alegría, Luz Belinda; Calderón-Segura, Esther; Conde-Glez, Carlos J; Cañedo-Solares, Irma; Correa, Dolores

    2014-05-14

    There are few articles on evaluation of Toxoplasma gondii serological tests. Besides, commercially available tests are not always useful and are expensive for studies in open population. The aim of this study was to evaluate in-house ELISA and western blot for IgG antibodies in a representative sample of people living in Mexico. Three hundred and five serum samples were randomly selected from two national seroepidemiological survey banks; they were taken from men and women of all ages and from all areas of the country. ELISA cut-off was established using the mean plus three standard deviations of negative samples. Western blots were analysed by two experienced technicians and positivity was established according to the presence of at least three diagnostic bands. A commercial ELISA kit was used as a third test. Two reference standards were built up: one using concordant results of two assays leaving the evaluated test out and the other in which the evaluated test was included (IN) with at least two concordant results to define diagnosis. the lowest values of diagnostic parameters were obtained with the OUT reference standards: in-house ELISA had 96.9% sensitivity, 62.1% specificity, 49.6% PPV, 98.1% NPV and 71.8% accuracy, while western blot presented 81.8%, 89.7%, 84.0%, 88.2% and 86.6% values and the best kappa coefficient (0.72-0.82). The in-house ELISA is useful for screening people of Mexico, due to its high sensitivity, while western blot may be used to confirm diagnosis. These techniques might prove useful in other Latin American countries.

  7. Efficient strategies to find diagnostic test accuracy studies in kidney journals.

    PubMed

    Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C

    2015-08-01

    Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.

  8. Component-resolved diagnostics in vernal conjunctivitis.

    PubMed

    Armentia, Alicia; Sanchís, Eugenia; Montero, Javier A

    2016-10-01

    Conventional diagnostic tests in allergy are insufficient to clarify the cause of vernal conjunctivitis. Component-resolved diagnostic (CRD) by microarray allergen assay may be useful in detecting allergens that might be involved in the inflammatory process. In a recent trial in patients suffered from eosinophilic esophagitis, after 2 years of the CRD-guided exclusion diet and specific immunotherapy, significant clinical improvement was observed, and 68% of patients were discharged (cure based on negative biopsy, no symptoms, and no medication intake). Our new objective was to evaluate IgE-mediated hypersensitivity by CRD in tears and serum from patients with vernal conjunctivitis and treat patients with identified triggering allergens by specific immunotherapy. Twenty-five patients with vernal conjunctivitis were evaluated. The identified triggering allergens were n Lol p 1 (11 cases), n Cyn d 1 (eight cases), group 4 and 6 grasses (six cases) and group 5 of grasses (five cases). Prick test and pollen IgE were positive in one case. Clinical improvement was observed in 13/25 vernal conjunctivitis patients after 1-year specific immunotherapy. CRD seems to be a more sensitive diagnostic tool compared with prick test and IgE detection. Specific CRD-led immunotherapy may achieve clinical improvements in vernal conjunctivitis patients.

  9. Identification student’s misconception of heat and temperature using three-tier diagnostic test

    NASA Astrophysics Data System (ADS)

    Suliyanah; Putri, H. N. P. A.; Rohmawati, L.

    2018-03-01

    The objective of this research is to develop a Three-Tier Diagnostic Test (TTDT) to identify the student's misconception of heat and temperature. Stages of development include: analysis, planning, design, development, evaluation and revise. The results of this study show that (1) the quality of the three-tier type diagnostic test instrument developed has been expressed well with the following details: (a) Internal validity of 88.19% belonging to the valid category. (b) External validity of empirical construct validity test using Pearson Product Moment obtained 0.43 is classified and result of empirical construct validity test obtained false positives 6.1% and false negatives 5.9% then the instrument was valid. (c) Test reliability by using Cronbach’s Alpha of 0.98 which means acceptable. (d) The 80% difficulty level test is quite difficult. (2) Student misconceptions on the temperature of heat and displacement materials based on the II test the highest (84%), the lowest (21%), and the non-misconceptions (7%). (3) The highest cause of misconception among students is associative thinking (22%) and the lowest is caused by incomplete or incomplete reasoning (11%). Three-Tier Diagnostic Test (TTDT) could identify the student's misconception of heat and temperature.

  10. A multimedia patient simulation for teaching and assessing endodontic diagnosis.

    PubMed

    Littlefield, John H; Demps, Elaine L; Keiser, Karl; Chatterjee, Lipika; Yuan, Cheng H; Hargreaves, Kenneth M

    2003-06-01

    Teaching and assessing diagnostic skills are difficult due to relatively small numbers of total clinical experiences and a shortage of clinical faculty. Patient simulations could help teach and assess diagnosis by displaying a well-defined diagnostic task, then providing informative feedback and opportunities for repetition and correction of errors. This report describes the development and initial evaluation of SimEndo I, a multimedia patient simulation program that could be used for teaching or assessing endodontic diagnosis. Students interact with a graphical interface that has four pull-down menus and related submenus. In response to student requests, the program presents patient information. Scoring is based on diagnosis of each case by endodontists. Pilot testing with seventy-four junior dental students identified numerous needed improvements to the user interface program. A multi-school field test of the interface program using three patient cases addressed three research questions: 1) How did the field test students evaluate SimEndo I? Overall mean evaluation was 8.1 on a 0 to 10 scale; 2) How many cases are needed to generate a reproducible diagnostic proficiency score for an individual student using the Rimoldi scoring procedure? Mean diagnostic proficiency scores by case ranged from .27 to .40 on a 0 to 1 scale; five cases would produce a score with a 0.80 reliability coefficient; and 3) Did students accurately diagnose each case? Mean correct diagnosis scores by case ranged from .54 to .78 on a 0 to 1 scale. We conclude that multimedia patient simulations offer a promising alternative for teaching and assessing student diagnostic skills.

  11. Compression evaluation of surgery video recordings retaining diagnostic credibility (compression evaluation of surgery video)

    NASA Astrophysics Data System (ADS)

    Duplaga, M.; Leszczuk, M. I.; Papir, Z.; Przelaskowski, A.

    2008-12-01

    Wider dissemination of medical digital video libraries is affected by two correlated factors, resource effective content compression that directly influences its diagnostic credibility. It has been proved that it is possible to meet these contradictory requirements halfway for long-lasting and low motion surgery recordings at compression ratios close to 100 (bronchoscopic procedures were a case study investigated). As the main supporting assumption, it has been accepted that the content can be compressed as far as clinicians are not able to sense a loss of video diagnostic fidelity (a visually lossless compression). Different market codecs were inspected by means of the combined subjective and objective tests toward their usability in medical video libraries. Subjective tests involved a panel of clinicians who had to classify compressed bronchoscopic video content according to its quality under the bubble sort algorithm. For objective tests, two metrics (hybrid vector measure and hosaka Plots) were calculated frame by frame and averaged over a whole sequence.

  12. Use of 3×2 tables with an intention to diagnose approach to assess clinical performance of diagnostic tests: meta-analytical evaluation of coronary CT angiography studies

    PubMed Central

    Schuetz, Georg M; Schlattmann, Peter

    2012-01-01

    Objective To determine whether a 3×2 table, using an intention to diagnose approach, is better than the “classic” 2×2 table at handling transparent reporting and non-evaluable results, when assessing the accuracy of a diagnostic test. Design Based on a systematic search for diagnostic accuracy studies of coronary computed tomography (CT) angiography, full texts of relevant studies were evaluated to determine whether they could calculate an alternative 3×2 table. To quantify an overall effect, we pooled diagnostic accuracy values according to a meta-analytical approach. Data sources Medline (via PubMed), Embase (via Ovid), and ISI Web of Science electronic databases. Eligibility criteria Prospective English or German language studies comparing coronary CT with conventional coronary angiography in all patients and providing sufficient data for a patient level analysis. Results 120 studies (10 287 patients) were eligible. Studies varied greatly in their approaches to handling non-evaluable findings. We found 26 studies (including 2298 patients) that allowed us to calculate both 2×2 tables and 3×2 tables. Using a bivariate random effects model, we compared the 2×2 table with the 3×2 table, and found significant differences for pooled sensitivity (98.2 (95% confidence interval 96.7 to 99.1) v 92.7 (88.5 to 95.3)), area under the curve (0.99 (0.98 to 1.00) v 0.93 (0.91 to 0.95)), positive likelihood ratio (9.1 (6.2 to 13.3) v 4.4 (3.3 to 6.0)), and negative likelihood ratio (0.02 (0.01 to 0.04) v 0.09 (0.06 to 0.15); (P<0.05)). Conclusion Parameters for diagnostic performance significantly decrease if non-evaluable results are included by a 3×2 table for analysis (intention to diagnose approach). This approach provides a more realistic picture of the clinical potential of diagnostic tests. PMID:23097549

  13. Use of clinical prediction rules and D-dimer tests in the diagnostic management of pregnant patients with suspected acute pulmonary embolism.

    PubMed

    Van der Pol, L M; Mairuhu, A T A; Tromeur, C; Couturaud, F; Huisman, M V; Klok, F A

    2017-03-01

    Because pregnant women have an increased risk of venous thromboembolism (VTE) and at the same time normal pregnancy is associated with symptoms, mimicking those present in the setting of acute pulmonary embolism (PE), the latter diagnosis is frequently suspected in this patient category. Since imaging tests expose both mother and foetus to ionizing radiation, the ability to rule out PE based on non-radiological diagnostic tests is of paramount importance. However, clinical decision rules have only been scarcely evaluated in the pregnant population with suspected PE, while D-dimer levels lose diagnostic accuracy due to a physiological increase during normal pregnancy. Consequently, clinical guidelines provide contradicting and weak recommendations on this subject and the optimal diagnostic strategy remains highly debated. With this systematic review, we aimed to summarize current evidence on the safety and efficacy of clinical decision rules and biomarkers used in the diagnostic management of suspected acute PE in pregnant patients. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  15. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  16. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  17. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  18. 21 CFR 890.1925 - Isokinetic testing and evaluation system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Isokinetic testing and evaluation system. 890.1925 Section 890.1925 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Diagnostic Devices § 890.1925...

  19. Uncertainty during breast diagnostic evaluation: state of the science.

    PubMed

    Montgomery, Mariann

    2010-01-01

    To present the state of the science on uncertainty in relationship to the experiences of women undergoing diagnostic evaluation for suspected breast cancer. Published articles from Medline, CINAHL, PubMED, and PsycINFO from 1983-2008 using the following key words: breast biopsy, mammography, uncertainty, reframing, inner strength, and disruption. Fifty research studies were examined with all reporting the presence of anxiety persisting throughout the diagnostic evaluation until certitude is achieved through the establishment of a definitive diagnosis. Indirect determinants of uncertainty for women undergoing breast diagnostic evaluation include measures of anxiety, depression, social support, emotional responses, defense mechanisms, and the psychological impact of events. Understanding and influencing the uncertainty experience have been suggested to be key in relieving psychosocial distress and positively influencing future screening behaviors. Several studies examine correlational relationships among anxiety, selection of coping methods, and demographic factors that influence uncertainty. A gap exists in the literature with regard to the relationship of inner strength and uncertainty. Nurses can be invaluable in assisting women in coping with the uncertainty experience by providing positive communication and support. Nursing interventions should be designed and tested for their effects on uncertainty experienced by women undergoing a breast diagnostic evaluation.

  20. Evaluating the diagnostic accuracy of Arabic SNAP test for children with hypernasality.

    PubMed

    Abou-Elsaad, Tamer; Afsah, Omayma; Baz, Hemmat; Mansy, Alzahraa

    2016-06-01

    Nasometry is a method of measuring the acoustic correlates of resonance through a computer-based instrument called nasometer. High nasalance scores in comparison to normative data suggest hypernasality and/or other nasality disorders, while low scores suggest hyponasality. Normative values of nasalance for Egyptian Arabic speakers were established using the Arabic SNAP (Simplified Nasometric Assessment Procedures) test. to evaluate the diagnostic accuracy of Arabic SNAP test to allow for its use in the differentiation between normal and hypernasal speech in Egyptian Arabic-speaking children. Nasalance scores of normal children (n=92) on Arabic SNAP test were compared to those of 30 children with velopharyngeal insufficiency due to cleft palate. Receiver operating characteristic (ROC) curve was used to determine cutoff points with the highest sensitivity and specificity. Statistically significant differences were found between both groups for all items in nasometric evaluation (p<0.05) except for prolonged/m/sound (p>0.05). Cutoff points were determined and certain items were selected for routine nasometric evaluation. The Arabic SNAP test is a sensitive and specific tool for evaluation of children with hypernasality and can be used for both diagnosis and follow up of these cases. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Test-retest reliability of a standardized psychiatric interview (DIS/CIDI).

    PubMed

    Semler, G; Wittchen, H U; Joschke, K; Zaudig, M; von Geiso, T; Kaiser, S; von Cranach, M; Pfister, H

    1987-01-01

    The reliability of DSM-III diagnoses using an expanded version of the Diagnostic Interview Schedule (DIS), called the Composite International Diagnostic Interview (CIDI), was evaluated by examining 60 psychiatric inpatients on a test-retest basis. Acceptable agreement coefficients of (kappa) 0.5 or above were found for all but two disorders: dysthymic disorder and generalized anxiety disorder. The subclassification of DSM-III affective disorders also revealed some discrepancies between the test and the retest interviews. When compared with results from earlier versions of the DIS, diagnostic reliability was found to have improved for the DSM-III anxiety disorders in particular. These improvements can possibly be attributed to some changes in the wording of the respective items of this section. Several reasons for lowered test-retest reliability are discussed.

  2. Auditory brainstem response (ABR) profiling tests as diagnostic support for schizophrenia and adult attention-deficit hyperactivity disorder (ADHD).

    PubMed

    Juselius Baghdassarian, Eva; Nilsson Markhed, Maria; Lindström, Eva; Nilsson, Björn M; Lewander, Tommy

    2018-06-01

    To evaluate the performances of two auditory brainstem response (ABR) profiling tests as potential biomarkers and diagnostic support for schizophrenia and adult attention-deficit hyperactivity disorder (ADHD), respectively, in an investigator-initiated blinded study design. Male and female patients with schizophrenia (n=26) and adult ADHD (n=24) meeting Diagnostic and Statistical Manual of Mental Disorders Fourth Edition (DSM IV) diagnostic criteria and healthy controls (n=58) comprised the analysis set (n=108) of the total number of study participants (n=119). Coded sets of randomized ABR recordings were analysed by an independent party blinded to clinical diagnoses before a joint code-breaking session. The ABR profiling test for schizophrenia identified schizophrenia patients versus controls with a sensitivity of 84.6% and a specificity of 93.1%. The ADHD test identified patients with adult ADHD versus controls with a sensitivity of 87.5% and a specificity of 91.4%. The ABR profiling tests discriminated schizophrenia and ADHD versus healthy controls with high sensitivity and specificity. The methods deserve to be further explored in larger clinical studies including a broad range of psychiatric disorders to determine their utility as potential diagnostic biomarkers.

  3. Diagnostic accuracy of three monoclonal stool tests in a large series of untreated Helicobacter pylori infected patients.

    PubMed

    Lario, Sergio; Ramírez-Lázaro, María José; Montserrat, Antònia; Quílez, María Elisa; Junquera, Félix; Martínez-Bauer, Eva; Sanfeliu, Isabel; Brullet, Enric; Campo, Rafael; Segura, Ferran; Calvet, Xavier

    2016-06-01

    Immunochromatographic tests need to be improved in order to enhance their reliability. Recently, several new kits have appeared on the market. The objective was to evaluate the diagnostic accuracy of three monoclonal rapid stool tests - the new Uni-Gold™ H.pylori Antigen (Trinity Biotech, Ireland), the RAPID Hp StAR (Oxoid Ltd., UK) and the ImmunoCard STAT! HpSA (Meridian Diagnostics, USA) - for detecting H. pylori infection prior to eradication treatment. Diagnostic accuracy (sensitivity and specificity) and reliability (concordance between observers) were evaluated in 250 untreated consecutive dyspeptic patients. The gold standard for diagnosing H. pylori infection was defined as the concordance of two or more of rapid urease test (RUT), histopathology and urease breath test (UBT) or positive culture in isolation. Readings of immunochromatographic tests were performed by two different observers. Sensitivity, specificity, positive and negative predictive values and 95% confidence intervals were calculated. Sensitivity and specificity were compared using the McNemar test. The three tests showed a good correlation, with Kappa values>0.9. RAPID Hp StAR had a sensitivity of 91%-92% and a specificity ranging from 77% to 85%. Its sensitivity was higher than that of Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA (p<0.01). Uni-Gold™ H.pylori Antigen kit showed a sensitivity of 83%, similar to ImmunoCard STAT! HpSA. Specificity of Uni-Gold™ H.pylori Antigen approached 90% (87-89%) and was superior to that of RAPID Hp StAR (p<0.01). Uni-Gold™ H.pylori Antigen and ImmunoCard STAT! HpSA present similar levels of diagnostic accuracy. RAPID Hp StAR was the most sensitive but less reliable of the three immunochromatographic stool tests. None are as accurate and reliable as UBT, RUT and histology. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. A comparison of diagnostic tests for lactose malabsorption - which one is the best?

    PubMed Central

    2009-01-01

    Background Perceived milk intolerance is a common complaint, and tests for lactose malabsorption (LM) are unreliable. This study assesses the agreement between diagnostic tests for LM and describes the diagnostic properties of the tests. Methods Patients above 18 years of age with suspected LM were included. After oral intake of 25 g lactose, a combined test with measurement of serum glucose (s-glucose) and hydrogen (H2) and methane (CH4) in expired air was performed and symptoms were recorded. In patients with discrepancies between the results, the combined test was repeated and a gene test for lactose non-persistence was added. The diagnosis of LM was based on an evaluation of all tests. The following tests were compared: Increase in H2, CH4, H2+CH4 and H2+CH4x2 in expired air, increase in s-glucose, and symptoms. The agreement was calculated and the diagnostic properties described. Results Sixty patients were included, seven (12%) had LM. The agreement (kappa-values) between the methods varied from 0.25 to 0.91. The best test was the lactose breath test with measurement of the increase in H2 + CH4x2 in expired air. With a cut-off level < 18 ppm, the area under the ROC-curve was 0.967 and sensitivity was 100%. This shows that measurement of CH4 in addition to H2 improves the diagnostic properties of the breath test. Conclusion The agreement between commonly used methods for the diagnosis of LM was unsatisfactory. A lactose breath test with measurement of H2 + CH4x2 in expired air had the best diagnostic properties. PMID:19878587

  5. Endometrial biomarkers for the non-invasive diagnosis of endometriosis.

    PubMed

    Gupta, Devashana; Hull, M Louise; Fraser, Ian; Miller, Laura; Bossuyt, Patrick M M; Johnson, Neil; Nisenblat, Vicki

    2016-04-20

    About 10% of reproductive-aged women suffer from endometriosis, which is a costly, chronic disease that causes pelvic pain and subfertility. Laparoscopy is the gold standard diagnostic test for endometriosis, but it is expensive and carries surgical risks. Currently, there are no non-invasive tests available in clinical practice that accurately diagnose endometriosis. This is the first diagnostic test accuracy review of endometrial biomarkers for endometriosis that utilises Cochrane methodologies, providing an update on the rapidly expanding literature in this field. To determine the diagnostic accuracy of the endometrial biomarkers for pelvic endometriosis, using a surgical diagnosis as the reference standard. We evaluated the tests as replacement tests for diagnostic surgery and as triage tests to inform decisions to undertake surgery for endometriosis. We did not restrict the searches to particular study designs, language or publication dates. To identify trials, we searched the following databases: CENTRAL (2015, July), MEDLINE (inception to May 2015), EMBASE (inception to May 2015), CINAHL (inception to April 2015), PsycINFO (inception to April 2015), Web of Science (inception to April 2015), LILACS (inception to April 2015), OAIster (inception to April 2015), TRIP (inception to April 2015) and ClinicalTrials.gov (inception to April 2015). We searched DARE and PubMed databases up to April 2015 to identify reviews and guidelines as sources of references to potentially relevant studies. We also performed searches for papers recently published and not yet indexed in the major databases. The search strategies incorporated words in the title, abstract, text words across the record and the medical subject headings (MeSH). We considered published peer-reviewed, randomised controlled or cross-sectional studies of any size that included prospectively collected samples from any population of reproductive-aged women suspected of having one or more of the following target conditions: ovarian, peritoneal or deep infiltrating endometriosis (DIE). Two authors independently extracted data from each study and performed a quality assessment. For each endometrial diagnostic test, we classified the data as positive or negative for the surgical detection of endometriosis and calculated the estimates of sensitivity and specificity. We considered two or more tests evaluated in the same cohort as separate data sets. We used the bivariate model to obtain pooled estimates of sensitivity and specificity whenever sufficient data were available. The predetermined criteria for a clinically useful test to replace diagnostic surgery was one with a sensitivity of 94% and a specificity of 79%. The criteria for triage tests were set at sensitivity at or above 95% and specificity at or above 50%, which in case of negative results rules out the diagnosis (SnOUT test) or sensitivity at or above 50% with specificity at or above 95%, which in case of positive result rules in the diagnosis (SpIN test). We included 54 studies involving 2729 participants, most of which were of poor methodological quality. The studies evaluated endometrial biomarkers either in specific phases of the menstrual cycle or outside of it, and the studies tested the biomarkers either in menstrual fluid, in whole endometrial tissue or in separate endometrial components. Twenty-seven studies evaluated the diagnostic performance of 22 endometrial biomarkers for endometriosis. These were angiogenesis and growth factors (PROK-1), cell-adhesion molecules (integrins α3β1, α4β1, β1 and α6), DNA-repair molecules (hTERT), endometrial and mitochondrial proteome, hormonal markers (CYP19, 17βHSD2, ER-α, ER-β), inflammatory markers (IL-1R2), myogenic markers (caldesmon, CALD-1), neural markers (PGP 9.5, VIP, CGRP, SP, NPY, NF) and tumour markers (CA-125). Most of these biomarkers were assessed in single studies, whilst only data for PGP 9.5 and CYP19 were available for meta-analysis. These two biomarkers demonstrated significant diversity for the diagnostic estimates between the studies; however, the data were too limited to reliably determine the sources of heterogeneity. The mean sensitivities and specificities of PGP 9.5 (7 studies, 361 women) were 0.96 (95% confidence interval (CI) 0.91 to 1.00) and 0.86 (95% CI 0.70 to 1.00), after excluding one outlier study, and for CYP19 (8 studies, 444 women), they were were 0.77 (95% CI 0.70 to 0.85) and 0.74 (95% CI 0.65 to 84), respectively. We could not statistically evaluate other biomarkers in a meaningful way. An additional 31 studies evaluated 77 biomarkers that showed no evidence of differences in expression levels between the groups of women with and without endometriosis. We could not statistically evaluate most of the biomarkers assessed in this review in a meaningful way. In view of the low quality of most of the included studies, the findings of this review should be interpreted with caution. Although PGP 9.5 met the criteria for a replacement test, it demonstrated considerable inter study heterogeneity in diagnostic estimates, the source of which could not be determined. Several endometrial biomarkers, such as endometrial proteome, 17βHSD2, IL-1R2, caldesmon and other neural markers (VIP, CGRP, SP, NPY and combination of VIP, PGP 9.5 and SP) showed promising evidence of diagnostic accuracy, but there was insufficient or poor quality evidence for any clinical recommendations. Laparoscopy remains the gold standard for the diagnosis of endometriosis, and using any non-invasive tests should only be undertaken in a research setting. We have also identified a number of biomarkers that demonstrated no diagnostic value for endometriosis. We recommend that researchers direct future studies towards biomarkers with high diagnostic potential in good quality diagnostic studies.

  6. Applications of Diagnostic Classification Models: A Literature Review and Critical Commentary

    ERIC Educational Resources Information Center

    Sessoms, John; Henson, Robert A.

    2018-01-01

    Diagnostic classification models (DCMs) classify examinees based on the skills they have mastered given their test performance. This classification enables targeted feedback that can inform remedial instruction. Unfortunately, applications of DCMs have been criticized (e.g., no validity support). Generally, these evaluations have been brief and…

  7. Evaluation of molecular markers for Phytophthora ramorum detection and identification: Testing for specificity using a standardized library of isolates

    Treesearch

    F.N. Martin; M.D. Coffey; K. Zeller; R.C. Hamelin; P. Tooley; M. Garbelotto; K.J.D. Hughes; T. Kubisiak; G.J. Bilodeau; L. Levy; C. Blomquist; P.H. Berger

    2009-01-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World...

  8. Update on diagnostic value of breath test in gastrointestinal and liver diseases

    PubMed Central

    Siddiqui, Imran; Ahmed, Sibtain; Abid, Shahab

    2016-01-01

    In the field of gastroenterology, breath tests (BTs) are used intermittently as diagnostic tools that allow indirect, non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered. The aim of this review is to have an insight into the principles, methods of analysis and performance parameters of various hydrogen, methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection, small intestinal bacterial overgrowth, and carbohydrate malabsorption. Evaluation of gastric emptying is routinely performed by scintigraphy which is however, difficult to perform and not suitable for children and pregnant women, this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges. A new development such as electronic nose test is also highlighted. Moreover we have also explored the limitations and constraints restraining the wide use of these BT. We conclude that breath testing has an enormous potential to be used as a diagnostic modality. In addition it offers distinct advantages over the traditional invasive methods commonly employed. PMID:27574563

  9. Designs and adaptive analysis plans for pivotal clinical trials of therapeutics and companion diagnostics.

    PubMed

    Simon, Richard

    2008-06-01

    Developments in genomics and biotechnology provide unprecedented opportunities for the development of effective therapeutics and companion diagnostics for matching the right drug to the right patient. Effective co-development involves many new challenges with increased opportunity for success as well as delay and failure. Clinical trial designs and adaptive analysis plans for the prospective design of pivotal trials of new therapeutics and companion diagnostics are reviewed. Effective co-development requires careful prospective planning of the design and analysis strategy for pivotal clinical trials. Randomized clinical trials continue to be important for evaluating the effectiveness of new treatments, but the target populations for analysis should be prospectively specified based on the companion diagnostic. Post hoc analyses of traditionally designed randomized clinical trials are often deeply problematic. Clear separation is generally required of the data used for developing the diagnostic test, including their threshold of positivity, from the data used for evaluating treatment effectiveness in subsets determined by the test. Adaptive analysis can be used to provide flexibility to the analysis but the use of such methods requires careful planning and prospective definition in order to assure that the pivotal trial adequately limits the chance of erroneous conclusions.

  10. Variation in Results Release and Patient Portal Access to Diagnostic Test Results at an Academic Medical Center

    PubMed Central

    Krasowski, Matthew D.; Grieme, Caleb V.; Cassady, Brian; Dreyer, Nicholas R.; Wanat, Karolyn A.; Hightower, Maia; Nepple, Kenneth G.

    2017-01-01

    Background: Electronic health records (EHRs) are commonplace in industrialized countries. Many hospitals are granting their patients access to their medical information through online patient portals. In this report, we describe a retrospective analysis of patient access to diagnostic test results released through the patient portal (MyChart; Epic, Inc.) at a state academic medical center. Methods: We analyzed 6 months of data for anatomic pathology, clinical laboratory, and radiology test results to evaluate variations in results release (automated vs. manual) and subsequent patient access to the institutional patient portal. During this period, diagnostic test results were released for all patient encounters including inpatient units, outpatient clinics, and the emergency department. Results: Manual results release by providers before automated release time occurred most commonly in the outpatient setting. The highest rates of access of diagnostic test results occurred for outpatients (about 30% overall view rate), females (two times or more compared to males in nearly every age bracket), and 20–45-year-old. Access rates of diagnostic tests in the emergency department or inpatient units were <10% across all populations. Access of diagnostic test results was very low for 12–17-year-old, likely influenced by institutional policies limiting parental proxy access within this pediatric age range. Approximately 20% of outpatient laboratory results were viewed by patients within 8 h of release from the EHR to the patient portal and 10% within 2 h of release. Conclusions: Patient accessing of diagnostic test results were generally higher for females, outpatients, and 20–45-year-old. Approximately, 20% of outpatient results were viewed quickly by patients after release to the EHR. PMID:29226008

  11. Variation in Results Release and Patient Portal Access to Diagnostic Test Results at an Academic Medical Center.

    PubMed

    Krasowski, Matthew D; Grieme, Caleb V; Cassady, Brian; Dreyer, Nicholas R; Wanat, Karolyn A; Hightower, Maia; Nepple, Kenneth G

    2017-01-01

    Electronic health records (EHRs) are commonplace in industrialized countries. Many hospitals are granting their patients access to their medical information through online patient portals. In this report, we describe a retrospective analysis of patient access to diagnostic test results released through the patient portal (MyChart; Epic, Inc.) at a state academic medical center. We analyzed 6 months of data for anatomic pathology, clinical laboratory, and radiology test results to evaluate variations in results release (automated vs. manual) and subsequent patient access to the institutional patient portal. During this period, diagnostic test results were released for all patient encounters including inpatient units, outpatient clinics, and the emergency department. Manual results release by providers before automated release time occurred most commonly in the outpatient setting. The highest rates of access of diagnostic test results occurred for outpatients (about 30% overall view rate), females (two times or more compared to males in nearly every age bracket), and 20-45-year-old. Access rates of diagnostic tests in the emergency department or inpatient units were <10% across all populations. Access of diagnostic test results was very low for 12-17-year-old, likely influenced by institutional policies limiting parental proxy access within this pediatric age range. Approximately 20% of outpatient laboratory results were viewed by patients within 8 h of release from the EHR to the patient portal and 10% within 2 h of release. Patient accessing of diagnostic test results were generally higher for females, outpatients, and 20-45-year-old. Approximately, 20% of outpatient results were viewed quickly by patients after release to the EHR.

  12. Assessing Old and New Diagnostic Tests for Gastroesophageal Reflux Disease.

    PubMed

    Vaezi, Michael F; Sifrim, Daniel

    2018-01-01

    A detailed critique of objective measurements of gastroesophageal reflux disease (GERD) would improve management of patients suspecting of having reflux, leading to rational selection of treatment and better outcomes. Many diagnostic tests for GERD have been developed over the past decades. We analyze their development, positive- and negative-predictive values, and ability to predict response to treatment. These features are important for development of medical, surgical, and endoscopic therapies for GERD. We discuss the value of available diagnostic tests and review their role in management of patients with persistent reflux symptoms despite adequate medical or surgical treatment. This is becoming a significant health economic problem, due to the widespread use of proton pump inhibitors. GERD is believed to cause nonesophageal symptoms, such as those provoked by ear, nose, throat, or respiratory disorders. We analyze the value of GERD diagnostic tests in evaluation of these troublesome, nonesophageal symptoms. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  13. Diagnostic validity of physical examination tests for common knee disorders: An overview of systematic reviews and meta-analysis.

    PubMed

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Roy, Jean-Sébastien; Desmeules, François

    2017-01-01

    More evidence on diagnostic validity of physical examination tests for knee disorders is needed to lower frequently used and costly imaging tests. To conduct a systematic review of systematic reviews (SR) and meta-analyses (MA) evaluating the diagnostic validity of physical examination tests for knee disorders. A structured literature search was conducted in five databases until January 2016. Methodological quality was assessed using the AMSTAR. Seventeen reviews were included with mean AMSTAR score of 5.5 ± 2.3. Based on six SR, only the Lachman test for ACL injuries is diagnostically valid when individually performed (Likelihood ratio (LR+):10.2, LR-:0.2). Based on two SR, the Ottawa Knee Rule is a valid screening tool for knee fractures (LR-:0.05). Based on one SR, the EULAR criteria had a post-test probability of 99% for the diagnosis of knee osteoarthritis. Based on two SR, a complete physical examination performed by a trained health provider was found to be diagnostically valid for ACL, PCL and meniscal injuries as well as for cartilage lesions. When individually performed, common physical tests are rarely able to rule in or rule out a specific knee disorder, except the Lachman for ACL injuries. There is low-quality evidence concerning the validity of combining history elements and physical tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Demystifying the Clinical Diagnosis of Greater Trochanteric Pain Syndrome in Women.

    PubMed

    Ganderton, Charlotte; Semciw, Adam; Cook, Jill; Pizzari, Tania

    2017-06-01

    To evaluate the diagnostic accuracy of 10 clinical tests that can be used in the diagnosis of greater trochanteric pain syndrome (GTPS) in women, and to compare these clinical tests to magnetic resonance imaging (MRI) findings. Twenty-eight participants with GTPS (49.5 ± 22.0 years) and 18 asymptomatic participants (mean age ± standard deviation [SD], 52.5 ± 22.8 years) were included. A blinded physiotherapist performed 10 pain provocation tests potentially diagnostic for GTPS-palpation of the greater trochanter, resisted external derotation test, modified resisted external derotation test, standard and modified Ober's tests, Patrick's or FABER test, resisted hip abduction, single-leg stance test, and the resisted hip internal rotation test. A sample of 16 symptomatic and 17 asymptomatic women undertook a hip MRI scan. Gluteal tendons were evaluated and categorized as no pathology, mild tendinosis, moderate tendinosis/partial tear, or full-thickness tear. Clinical test analyses show high specificity, high positive predictive value, low to moderate sensitivity, and negative predictive value for most clinical tests. All symptomatic and 88% of asymptomatic participants had pathological gluteal tendon changes on MRI, from mild tendinosis to full-thickness tear. The study found the Patrick's or FABER test, palpation of the greater trochanter, resisted hip abduction, and the resisted external derotation test to have the highest diagnostic test accuracy for GTPS. Tendon pathology on MRI is seen in both symptomatic and asymptomatic women.

  15. Investigation of Gear and Bearing Fatigue Damage Using Debris Particle Distributions

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Lewicki, David G.; Decker, Harry J.

    2004-01-01

    A diagnostic tool was developed for detecting fatigue damage to spur gears, spiral bevel gears, and rolling element bearings. This diagnostic tool was developed and evaluated experimentally by collecting oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Rig, Spiral Bevel Gear Test Facility, and the 500hp Helicopter Transmission Test Stand. During each test, data from an online, in-line, inductance type oil debris sensor was monitored and recorded for the occurrence of pitting damage. Results indicate oil debris alone cannot discriminate between bearing and gear fatigue damage.

  16. Introducing new diagnostics into STI control programmes: the importance of programme science.

    PubMed

    Peeling, Rosanna W; Mabey, David; Ballard, Ronald C

    2013-03-01

    Many innovative diagnostic technologies will become commercially available over the next 5-10 years. These tests can potentially transform the diagnosis of sexually transmitted infections but their introduction into control programmes can be hampered by health system constraints, and political, cultural, socioeconomic and behavioural factors. We used the introduction of syphilis rapid tests to illustrate the importance of programme science to address the gap between accruing evidence of acceptable test performance and the complexity of programme design, implementation and evaluation of test deployment to address public health needs and improve patient-important outcomes.

  17. Diagnosis of Caprine Arthritis Encephalitis Virus infection in dairy goats by ELISA, PCR and Viral Culture.

    PubMed

    Panneum, S; Rukkwamsuk, T

    2017-03-01

    For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.

  18. Diagnostic accuracy and prognostic significance of blood fibrosis tests and liver stiffness measurement by FibroScan in non-alcoholic fatty liver disease.

    PubMed

    Boursier, Jérôme; Vergniol, Julien; Guillet, Anne; Hiriart, Jean-Baptiste; Lannes, Adrien; Le Bail, Brigitte; Michalak, Sophie; Chermak, Faiza; Bertrais, Sandrine; Foucher, Juliette; Oberti, Frédéric; Charbonnier, Maude; Fouchard-Hubert, Isabelle; Rousselet, Marie-Christine; Calès, Paul; de Lédinghen, Victor

    2016-09-01

    NAFLD is highly prevalent but only a small subset of patients develop advanced liver fibrosis with impaired liver-related prognosis. We aimed to compare blood fibrosis tests and liver stiffness measurement (LSM) by FibroScan for the diagnosis of liver fibrosis and the evaluation of prognosis in NAFLD. Diagnostic accuracy was evaluated in a cross-sectional study including 452 NAFLD patients with liver biopsy (NASH-CRN fibrosis stage), LSM, and eight blood fibrosis tests (BARD, NAFLD fibrosis score, FibroMeter(NAFLD), aspartate aminotransferase to platelet ratio index (APRI), FIB4, FibroTest, Hepascore, FibroMeter(V2G)). Prognostic accuracy was evaluated in a longitudinal study including 360 NAFLD patients. LSM and FibroMeter(V2G) were the two best-performing tests in the cross-sectional study: AUROCs for advanced fibrosis (F3/4) were, respectively, 0.831±0.019 and 0.817±0.020 (p⩽0.041 vs. other tests); rates of patients with ⩾90% negative/positive predictive values for F3/4 were 56.4% and 46.7% (p<0.001 vs. other tests); Obuchowski indexes were 0.834±0.014 and 0.798±0.016 (p⩽0.036 vs. other tests). Two fibrosis classifications were developed to precisely estimate the histological fibrosis stage from LSM or FibroMeter(V2G) results without liver biopsy (diagnostic accuracy, respectively: 80.8% vs. 77.4%, p=0.190). Kaplan-Meier curves in the longitudinal study showed that both classifications categorised NAFLD patients into subgroups with significantly different prognoses (p<0.001): the higher was the class of the fibrosis classification, the worse was the prognosis. LSM and FibroMeter(V2G) were the most accurate of nine evaluated tests for the non-invasive diagnosis of liver fibrosis in NAFLD. LSM and FibroMeter(V2G) fibrosis classifications help physicians estimate both fibrosis stage and patient prognosis in clinical practice. The amount of liver fibrosis is the main determinant of the liver-related prognosis in patients with non-alcoholic fatty liver disease (NAFLD). We evaluated eight blood tests and FibroScan in a cross-sectional diagnostic study and found that FibroScan and the blood test FibroMeter(V2G) were the two most accurate tests for the non-invasive evaluation of liver fibrosis in NAFLD. A longitudinal prognostic study showed these two tests initially developed for the diagnosis are also prognostic markers as they allow for the stratification of NAFLD patients in several subgroups with significantly different prognosis. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  19. High diagnostic accuracy of subcutaneous Triptorelin test compared with GnRH test for diagnosing central precocious puberty in girls.

    PubMed

    Freire, Analía Verónica; Escobar, María Eugenia; Gryngarten, Mirta Graciela; Arcari, Andrea Josefina; Ballerini, María Gabriela; Bergadá, Ignacio; Ropelato, María Gabriela

    2013-03-01

    The GnRH test is the gold standard to confirm the diagnosis of central precocious puberty (CPP); however, this compound is not always readily available. Diagnostic accuracy of subcutaneous GnRH analogues tests compared to classical GnRH test has not been reported. To evaluate the diagnostic accuracy of Triptorelin test (index test) compared to the GnRH test (reference test) in girls with suspicion of CPP. A prospective, case-control, randomized clinical trial was performed. CPP or precocious thelarche (PT) was diagnosed according to maximal LH response to GnRH test and clinical characteristics during follow-up. Forty-six girls with premature breast development randomly underwent two tests: (i) intravenous GnRH 100 μg, (ii) subcutaneous Triptorelin acetate (0.1 mg/m(2), to a maximum of 0.1 mg) with blood sampling at 0, 3 and 24 h for LH, FSH and estradiol ascertainment. Gonadotrophins and estradiol responses to Triptorelin test were measured by ultrasensitive assays. Clinical features were similar between CPP (n = 33) and PT (n = 13) groups. Using receiver operating characteristic curves, maximal LH response (LH-3 h) under Triptorelin test ≥ 7 IU/l by immunofluorometric assay (IFMA) or ≥ 8 IU/l by electrochemiluminescence immunoassay (ECLIA) confirmed the diagnosis of CPP with specificity of 1.00 (95% CI: 0.75-1.00) and sensitivity 0.76 (95% CI: 0.58-0.89). Considering either LH-3 h or maximal estradiol response at 24 h (cut-off value, 295 pm), maintaining the specificity at 1.00, the test sensitivity increased to 0.94 (95% CI: 0.80-0.99) and the diagnostic efficiency to 96%. The Triptorelin test had high accuracy for the differential diagnosis of CPP vs PT in girls providing a valid alternative to the classical GnRH test. This test also allowed a comprehensive evaluation of the pituitary-ovarian axis. © 2012 Blackwell Publishing Ltd.

  20. The utilization of circulating cell-free fetal DNA testing and decrease in invasive diagnostic procedures: an institutional experience.

    PubMed

    Pettit, K E; Hull, A D; Korty, L; Jones, M C; Pretorius, D H

    2014-10-01

    To characterize the patient population utilizing circulating cell-free fetal DNA (ccffDNA) testing at a large academic center and evaluate trends in the performance of invasive diagnostic procedures. A retrospective cohort study of all patients who underwent cell-free DNA testing from May to December 2012 was performed. During the study period, 206 patients had cell-free DNA testing. Of those, 75% (155/206) were of ages ⩾ 35 years. Of those undergoing ccffDNA testing, 41% had positive aneuploidy screening and 38% had abnormal ultrasound findings. Only 7% of the patients with negative ccffDNA testing opted for an invasive diagnostic procedure compared with 60% with positive testing (P<0.01). The rate of invasive procedures decreased from 5.9% of all visits to the center during a similar 8-month period in 2010 to 4.1% of all visits during the study period (P<0.01). Our data suggest that ccffDNA testing leads to reduced uptake of invasive procedures.

  1. Skin Testing for Allergic Rhinitis: A Health Technology Assessment

    PubMed Central

    Kabali, Conrad; Chan, Brian; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    Background Allergic rhinitis is the most common type of allergy worldwide. The accuracy of skin testing for allergic rhinitis is still debated. This health technology assessment had two objectives: to determine the diagnostic accuracy of skin-prick and intradermal testing in patients with suspected allergic rhinitis and to estimate the costs to the Ontario health system of skin testing for allergic rhinitis. Methods We searched All Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment Database, Cochrane Central Register of Controlled Trials, and NHS Economic Evaluation Database for studies that evaluated the diagnostic accuracy of skin-prick and intradermal testing for allergic rhinitis using nasal provocation as the reference standard. For the clinical evidence review, data extraction and quality assessment were performed using the QUADAS-2 tool. We used the bivariate random-effects model for meta-analysis. For the economic evidence review, we assessed studies using a modified checklist developed by the (United Kingdom) National Institute for Health and Care Excellence. We estimated the annual cost of skin testing for allergic rhinitis in Ontario for 2015 to 2017 using provincial data on testing volumes and costs. Results We meta-analyzed seven studies with a total of 430 patients that assessed the accuracy of skin-prick testing. The pooled pair of sensitivity and specificity for skin-prick testing was 85% and 77%, respectively. We did not perform a meta-analysis for the diagnostic accuracy of intradermal testing due to the small number of studies (n = 4). Of these, two evaluated the accuracy of intradermal testing in confirming negative skin-prick testing results, with sensitivity ranging from 27% to 50% and specificity ranging from 60% to 100%. The other two studies evaluated the accuracy of intradermal testing as a stand-alone tool for diagnosing allergic rhinitis, with sensitivity ranging from 60% to 79% and specificity ranging from 68% to 69%. We estimated the budget impact of continuing to publicly fund skin testing for allergic rhinitis in Ontario to be between $2.5 million and $3.0 million per year. Conclusions Skin-prick testing is moderately accurate in identifying subjects with or without allergic rhinitis. The diagnostic accuracy of intradermal testing could not be well established from this review. Our best estimate is that publicly funding skin testing for allergic rhinitis costs the Ontario government approximately $2.5 million to $3.0 million per year. PMID:27279928

  2. Skin Testing for Allergic Rhinitis: A Health Technology Assessment.

    PubMed

    2016-01-01

    Allergic rhinitis is the most common type of allergy worldwide. The accuracy of skin testing for allergic rhinitis is still debated. This health technology assessment had two objectives: to determine the diagnostic accuracy of skin-prick and intradermal testing in patients with suspected allergic rhinitis and to estimate the costs to the Ontario health system of skin testing for allergic rhinitis. We searched All Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment Database, Cochrane Central Register of Controlled Trials, and NHS Economic Evaluation Database for studies that evaluated the diagnostic accuracy of skin-prick and intradermal testing for allergic rhinitis using nasal provocation as the reference standard. For the clinical evidence review, data extraction and quality assessment were performed using the QUADAS-2 tool. We used the bivariate random-effects model for meta-analysis. For the economic evidence review, we assessed studies using a modified checklist developed by the (United Kingdom) National Institute for Health and Care Excellence. We estimated the annual cost of skin testing for allergic rhinitis in Ontario for 2015 to 2017 using provincial data on testing volumes and costs. We meta-analyzed seven studies with a total of 430 patients that assessed the accuracy of skin-prick testing. The pooled pair of sensitivity and specificity for skin-prick testing was 85% and 77%, respectively. We did not perform a meta-analysis for the diagnostic accuracy of intradermal testing due to the small number of studies (n = 4). Of these, two evaluated the accuracy of intradermal testing in confirming negative skin-prick testing results, with sensitivity ranging from 27% to 50% and specificity ranging from 60% to 100%. The other two studies evaluated the accuracy of intradermal testing as a stand-alone tool for diagnosing allergic rhinitis, with sensitivity ranging from 60% to 79% and specificity ranging from 68% to 69%. We estimated the budget impact of continuing to publicly fund skin testing for allergic rhinitis in Ontario to be between $2.5 million and $3.0 million per year. Skin-prick testing is moderately accurate in identifying subjects with or without allergic rhinitis. The diagnostic accuracy of intradermal testing could not be well established from this review. Our best estimate is that publicly funding skin testing for allergic rhinitis costs the Ontario government approximately $2.5 million to $3.0 million per year.

  3. (13)C breath tests in personalized medicine: fiction or reality?

    PubMed

    Modak, Anil S

    2009-11-01

    The concept of personalized medicine is gathering momentum as various biomarkers are being discovered and developed to lead to genotype and phenotype diagnostic tests, which will enable physicians to individualize therapy. Noninvasive, rapid (13)C breath tests have the potential to serve as clinically significant diagnostic tools, especially for evaluating the enzyme activity of polymorphic enzymes. This would enable physicians to rapidly identify responders/nonresponders to various drugs primarily metabolized by these enzymes prior to initiation of therapy. With the information on enzyme activity, the physician can prescribe the right drug, at the right dose, at the right time, to the right individual, for the right clinical outcome. However, the promise of the era of personalized medicine, including the novel (13)C breath tests, will have to overcome several regulatory, business and financial hurdles for diagnostic tests to become part of routine mainstream clinical practice over the next decade.

  4. [Peripheral lymphadenopathy in childhood--recommendations for diagnostic evaluation].

    PubMed

    Benesch, M; Kerbl, R; Wirnsberger, A; Stünzner, D; Mangge, H; Schenkeli, R; Deutsch, J

    2000-01-01

    Enlargement of peripheral lymph nodes most commonly caused by a local inflammatory process is frequently seen in childhood. The aim of the present study was to analyze the most common causes of peripheral lymphadenopathy and to develop a simple algorithm for the primary diagnostic evaluation of peripheral lymph node enlargement in this age group. Between April and September 1999 87 unselected children (median age: 5 1/2 years) with peripheral lymphadenopathy were referred to the Department of Pediatrics, University of Graz, for further investigation. EBV infection was diagnosed in 20 (23.0%) children. 19 (21.8%) patients had acute bacterial lymphadenitis. In 21 (24.1%) patients lymph node enlargement was classified as "post/parainfectious (viral)". Four patients each had toxoplasmosis and cat scratch disease. In 11 (12.6%) patients neither physical nor laboratory examinations revealed pathologic results. Among the remaining 8 children sarcoidosis and Hodgkin disease was diagnosed in one patient each. Small, soft, mobile, nontender, cervical, axillary or inguinal lymph nodes do not require further investigations. In case of enlarged, tender lymph nodes with overlying skin erythema and fever diagnostic evaluation should include complete blood count, erythrocyte sedimentation rate and/or c-reactive protein level, supplemented by appropriate antibody testing (EBV, CMV, Toxoplasma gondii, Bartonella henselae). Firm, enlarged, painless lymph nodes which are matted together and fixed to the skin or underlying tissues necessitate a more detailed diagnostic evaluation in order to exclude malignant or granulomatous diseases. Our study demonstrated that primary diagnostic evaluation of childhood peripheral lymphadenopathy is mainly based on clinical grounds. In most cases a small number of additionally performed laboratory tests allow to correctly identify the cause of the peripheral lymph node enlargement.

  5. Evaluation of a Diagnostic Encyclopedia Workstation for ovarian pathology.

    PubMed

    van Ginneken, A M; Baak, J P; Jansen, W; Smeulders, A W

    1990-10-01

    The Diagnostic Encyclopedia Workstation (DEW) is a computer system that provides completely integrated pictorial and textual information as reference knowledge in the field of ovarian pathology. The textual component comprises information per diagnosis such as descriptions of macroscopic and microscopic images, clinical signs, and prognosis. In addition, the system offers lists of differential diagnoses and criteria to differentiate among lists of differential diagnoses and criteria to differentiate among them. The present study evaluates to what extent the system influences the diagnostic process in efficiency and outcome. Therefore, two groups of six pathologists each, covering a wide spectrum of experience in ovarian pathology, participated in the evaluation of the DEW. The quality of the resulting diagnoses was statistically analyzed with the Wilcoxon rank sum test with respect to five different viewpoints: classification, morphology, clinical consequences, duration of diagnostic process, and consensus among the participants. The results are discussed and it is concluded that classification and morphology showed better results when books were used. The evaluation experiment was, however, very rigid and negatively biased with respect to the DEW system. Positive aspects of the encyclopedia are the easy access to diagnostic and differential diagnostic information and the large set of illustrations. Insight is acquired with respect to existing bottlenecks and how they may be overcome.

  6. Development of an antigen-based rapid diagnostic test for the identification of blowfly (Calliphoridae) species of forensic significance.

    PubMed

    McDonagh, Laura; Thornton, Chris; Wallman, James F; Stevens, Jamie R

    2009-06-01

    In this study we examine the limitations of currently used sequence-based approaches to blowfly (Calliphoridae) identification and evaluate the utility of an immunological approach to discriminate between blowfly species of forensic importance. By investigating antigenic similarity and dissimilarity between the first instar larval stages of four forensically important blowfly species, we have been able to identify immunoreactive proteins of potential use in the development of species-specific immuno-diagnostic tests. Here we outline our protein-based approach to species determination, and describe how it may be adapted to develop rapid diagnostic assays for the 'on-site' identification of blowfly species.

  7. Iridology: A systematic review.

    PubMed

    Ernst, E

    1999-02-01

    Iridologists claim to be able to diagnose medical conditions through abnormalities of pigmentation in the iris. This technique is popular in many countries. Therefore it is relevant to ask whether it is valid. To systematically review all interpretable tests of the validity of iridology as a diagnostic tool. DATA SOURCE AND EXTRACTION: Three independent literature searches were performed to identify all blinded tests. Data were extracted in a predefined, standardized fashion. Four case control studies were found. The majority of these investigations suggests that iridology is not a valid diagnostic method. The validity of iridology as a diagnostic tool is not supported by scientific evaluations. Patients and therapists should be discouraged from using this method.

  8. From accuracy to patient outcome and cost-effectiveness evaluations of diagnostic tests and biomarkers: an exemplary modelling study

    PubMed Central

    2013-01-01

    Background Proper evaluation of new diagnostic tests is required to reduce overutilization and to limit potential negative health effects and costs related to testing. A decision analytic modelling approach may be worthwhile when a diagnostic randomized controlled trial is not feasible. We demonstrate this by assessing the cost-effectiveness of modified transesophageal echocardiography (TEE) compared with manual palpation for the detection of atherosclerosis in the ascending aorta. Methods Based on a previous diagnostic accuracy study, actual Dutch reimbursement data, and evidence from literature we developed a Markov decision analytic model. Cost-effectiveness of modified TEE was assessed for a life time horizon and a health care perspective. Prevalence rates of atherosclerosis were age-dependent and low as well as high rates were applied. Probabilistic sensitivity analysis was applied. Results The model synthesized all available evidence on the risk of stroke in cardiac surgery patients. The modified TEE strategy consistently resulted in more adapted surgical procedures and, hence, a lower risk of stroke and a slightly higher number of life-years. With 10% prevalence of atherosclerosis the incremental cost-effectiveness ratio was €4,651 and €481 per quality-adjusted life year in 55-year-old men and women, respectively. In all patients aged 65 years or older the modified TEE strategy was cost saving and resulted in additional health benefits. Conclusions Decision analytic modelling to assess the cost-effectiveness of a new diagnostic test based on characteristics, costs and effects of the test itself and of the subsequent treatment options is both feasible and valuable. Our case study on modified TEE suggests that it may reduce the risk of stroke in cardiac surgery patients older than 55 years at acceptable cost-effectiveness levels. PMID:23368927

  9. Diagnostic accuracy of clinical tests of the hip: a systematic review with meta-analysis.

    PubMed

    Reiman, Michael P; Goode, Adam P; Hegedus, Eric J; Cook, Chad E; Wright, Alexis A

    2013-09-01

    Hip Physical Examination (HPE) tests have long been used to diagnose a myriad of intra-and extra-articular pathologies of the hip joint. Useful clinical utility is necessary to support diagnostic imaging and subsequent surgical decision making. Summarise and evaluate the current research and utility on the diagnostic accuracy of HPE tests for the hip joint germane to sports related injuries and pathology. A computer-assisted literature search of MEDLINE, CINHAL and EMBASE databases (January 1966 to January 2012) using keywords related to diagnostic accuracy of the hip joint. This systematic review with meta-analysis utilised the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for the search and reporting phases of the study. Der-Simonian and Laird random effects models were used to summarise sensitivities (SN), specificities (SP), likelihood ratios and diagnostic OR. The employed search strategy revealed 25 potential articles, with 10 demonstrating high quality. Fourteen articles qualified for meta-analysis. The meta-analysis demonstrated that most tests possess weak diagnostic properties with the exception of the patellar-pubic percussion test, which had excellent pooled SN 95 (95% CI 92 to 97%) and good specificity 86 (95% CI 78 to 92%). Several studies have investigated pathology in the hip. Few of the current studies are of substantial quality to dictate clinical decision-making. Currently, only the patellar-pubic percussion test is supported by the data as a stand-alone HPE test. Further studies involving high quality designs are needed to fully assess the value of HPE tests for patients with intra- and extra-articular hip dysfunction.

  10. Differential Diagnosis of Malaria on Truelab Uno®, a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications.

    PubMed

    Nair, Chandrasekhar Bhaskaran; Manjula, Jagannath; Subramani, Pradeep Annamalai; Nagendrappa, Prakash B; Manoj, Mulakkapurath Narayanan; Malpani, Sukriti; Pullela, Phani Kumar; Subbarao, Pillarisetti Venkata; Ramamoorthy, Siva; Ghosh, Susanta K

    2016-01-01

    Sensitive and specific detection of malarial parasites is crucial in controlling the significant malaria burden in the developing world. Also important is being able to identify life threatening Plasmodium falciparum malaria quickly and accurately to reduce malaria related mortality. Existing methods such as microscopy and rapid diagnostic tests (RDTs) have major shortcomings. Here, we describe a new real-time PCR-based diagnostic test device at point-of-care service for resource-limited settings. Truenat® Malaria, a chip-based microPCR test, was developed by bigtec Labs, Bangalore, India, for differential identification of Plasmodium falciparum and Plasmodium vivax parasites. The Truenat Malaria tests runs on bigtec's Truelab Uno® microPCR device, a handheld, battery operated, and easy-to-use real-time microPCR device. The performance of Truenat® Malaria was evaluated versus the WHO nested PCR protocol. The Truenat® Malaria was further evaluated in a triple-blinded study design using a sample panel of 281 specimens created from the clinical samples characterized by expert microscopy and a rapid diagnostic test kit by the National Institute of Malaria Research (NIMR). A comparative evaluation was done on the Truelab Uno® and a commercial real-time PCR system. The limit of detection of the Truenat Malaria assay was found to be <5 parasites/μl for both P. falciparum and P. vivax. The Truenat® Malaria test was found to have sensitivity and specificity of 100% each, compared to the WHO nested PCR protocol based on the evaluation of 100 samples. The sensitivity using expert microscopy as the reference standard was determined to be around 99.3% (95% CI: 95.5-99.9) at the species level. Mixed infections were identified more accurately by Truenat Malaria (32 samples identified as mixed) versus expert microscopy and RDTs which detected 4 and 5 mixed samples, respectively. The Truenat® Malaria microPCR test is a valuable diagnostic tool and implementation should be considered not only for malaria diagnosis but also for active surveillance and epidemiological intervention.

  11. Differential Diagnosis of Malaria on Truelab Uno®, a Portable, Real-Time, MicroPCR Device for Point-Of-Care Applications

    PubMed Central

    Nair, Chandrasekhar Bhaskaran; Manjula, Jagannath; Subramani, Pradeep Annamalai; Nagendrappa, Prakash B.; Manoj, Mulakkapurath Narayanan; Malpani, Sukriti; Pullela, Phani Kumar; Subbarao, Pillarisetti Venkata; Ramamoorthy, Siva; Ghosh, Susanta K.

    2016-01-01

    Background Sensitive and specific detection of malarial parasites is crucial in controlling the significant malaria burden in the developing world. Also important is being able to identify life threatening Plasmodium falciparum malaria quickly and accurately to reduce malaria related mortality. Existing methods such as microscopy and rapid diagnostic tests (RDTs) have major shortcomings. Here, we describe a new real-time PCR-based diagnostic test device at point-of-care service for resource-limited settings. Methods Truenat® Malaria, a chip-based microPCR test, was developed by bigtec Labs, Bangalore, India, for differential identification of Plasmodium falciparum and Plasmodium vivax parasites. The Truenat Malaria tests runs on bigtec’s Truelab Uno® microPCR device, a handheld, battery operated, and easy-to-use real-time microPCR device. The performance of Truenat® Malaria was evaluated versus the WHO nested PCR protocol. The Truenat® Malaria was further evaluated in a triple-blinded study design using a sample panel of 281 specimens created from the clinical samples characterized by expert microscopy and a rapid diagnostic test kit by the National Institute of Malaria Research (NIMR). A comparative evaluation was done on the Truelab Uno® and a commercial real-time PCR system. Results The limit of detection of the Truenat Malaria assay was found to be <5 parasites/μl for both P. falciparum and P. vivax. The Truenat® Malaria test was found to have sensitivity and specificity of 100% each, compared to the WHO nested PCR protocol based on the evaluation of 100 samples. The sensitivity using expert microscopy as the reference standard was determined to be around 99.3% (95% CI: 95.5–99.9) at the species level. Mixed infections were identified more accurately by Truenat Malaria (32 samples identified as mixed) versus expert microscopy and RDTs which detected 4 and 5 mixed samples, respectively. Conclusion The Truenat® Malaria microPCR test is a valuable diagnostic tool and implementation should be considered not only for malaria diagnosis but also for active surveillance and epidemiological intervention. PMID:26784111

  12. [Chronic diarrhoea: Definition, classification and diagnosis].

    PubMed

    Fernández-Bañares, Fernando; Accarino, Anna; Balboa, Agustín; Domènech, Eugeni; Esteve, Maria; Garcia-Planella, Esther; Guardiola, Jordi; Molero, Xavier; Rodríguez-Luna, Alba; Ruiz-Cerulla, Alexandra; Santos, Javier; Vaquero, Eva

    2016-10-01

    Chronic diarrhoea is a common presenting symptom in both primary care medicine and in specialized gastroenterology clinics. It is estimated that >5% of the population has chronic diarrhoea and nearly 40% of these patients are older than 60 years. Clinicians often need to select the best diagnostic approach to these patients and choose between the multiple diagnostic tests available. In 2014 the Catalan Society of Gastroenterology formed a working group with the main objective of creating diagnostic algorithms based on clinical practice and to evaluate diagnostic tests and the scientific evidence available for their use. The GRADE system was used to classify scientific evidence and strength of recommendations. The consensus document contains 28 recommendations and 6 diagnostic algorithms. The document also describes criteria for referral from primary to specialized care. Copyright © 2015 Elsevier España, S.L.U. y AEEH y AEG. All rights reserved.

  13. Specialized data analysis for the Space Shuttle Main Engine and diagnostic evaluation of advanced propulsion system components

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The Marshall Space Flight Center is responsible for the development and management of advanced launch vehicle propulsion systems, including the Space Shuttle Main Engine (SSME), which is presently operational, and the Space Transportation Main Engine (STME) under development. The SSME's provide high performance within stringent constraints on size, weight, and reliability. Based on operational experience, continuous design improvement is in progress to enhance system durability and reliability. Specialized data analysis and interpretation is required in support of SSME and advanced propulsion system diagnostic evaluations. Comprehensive evaluation of the dynamic measurements obtained from test and flight operations is necessary to provide timely assessment of the vibrational characteristics indicating the operational status of turbomachinery and other critical engine components. Efficient performance of this effort is critical due to the significant impact of dynamic evaluation results on ground test and launch schedules, and requires direct familiarity with SSME and derivative systems, test data acquisition, and diagnostic software. Detailed analysis and evaluation of dynamic measurements obtained during SSME and advanced system ground test and flight operations was performed including analytical/statistical assessment of component dynamic behavior, and the development and implementation of analytical/statistical models to efficiently define nominal component dynamic characteristics, detect anomalous behavior, and assess machinery operational condition. In addition, the SSME and J-2 data will be applied to develop vibroacoustic environments for advanced propulsion system components, as required. This study will provide timely assessment of engine component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. This contract will be performed through accomplishment of negotiated task orders.

  14. Chromosomal Microarray With Clinical Diagnostic Utility in Children With Developmental Delay or Intellectual Disability.

    PubMed

    Lee, Jin Sook; Hwang, Hee; Kim, Soo Yeon; Kim, Ki Joong; Choi, Jin Sun; Woo, Mi Jung; Choi, Young Min; Jun, Jong Kwan; Lim, Byung Chan; Chae, Jong Hee

    2018-09-01

    Chromosomal microarray (CMA) testing is a first-tier test for patients with developmental delay, autism, or congenital anomalies. It increases diagnostic yield for patients with developmental delay or intellectual disability. In some countries, including Korea, CMA testing is not yet implemented in clinical practice. We assessed the diagnostic utility of CMA testing in a large cohort of patients with developmental delay or intellectual disability in Korea. We conducted a genome-wide microarray analysis of 649 consecutive patients with developmental delay or intellectual disability at the Seoul National University Children's Hospital. Medical records were reviewed retrospectively. Pathogenicity of detected copy number variations (CNVs) was evaluated by referencing previous reports or parental testing using FISH or quantitative PCR. We found 110 patients to have pathogenic CNVs, which included 100 deletions and 31 duplications of 270 kb to 30 Mb. The diagnostic yield was 16.9%, demonstrating the diagnostic utility of CMA testing in clinic. Parental testing was performed in 66 patients, 86.4% of which carried de novo CNVs. In eight patients, pathogenic CNVs were inherited from healthy parents with a balanced translocation, and genetic counseling was provided to these families. We verified five rarely reported deletions on 2p21p16.3, 3p21.31, 10p11.22, 14q24.2, and 21q22.13. This study demonstrated the clinical utility of CMA testing in the genetic diagnosis of patients with developmental delay or intellectual disability. CMA testing should be included as a clinical diagnostic test for all children with developmental delay or intellectual disability. © The Korean Society for Laboratory Medicine.

  15. Inter-laboratory evaluation of the performance parameters of a Lateral Flow Test device for the detection of Bluetongue virus-specific antibodies.

    PubMed

    Hanon, Jean-Baptiste; Vandenberge, Valerie; Deruelle, Matthias; De Leeuw, Ilse; De Clercq, Kris; Van Borm, Steven; Koenen, Frank; Liu, Lihong; Hoffmann, Bernd; Batten, Carrie Anne; Zientara, Stéphan; Breard, Emmanuel; Van der Stede, Yves

    2016-02-01

    Bluetongue (BT) is a viral vector-borne disease affecting domestic and wild ruminants worldwide. In this study, a commercial rapid immuno-chromatographic method or Lateral Flow Test (LFT) device, for the detection of BT virus-specific antibodies in animal serum, was evaluated in an international inter-laboratory proficiency test. The evaluation was done with sera samples of variable background (ruminant species, serotype, field samples, experimental infections, vaccinated animals). The diagnostic sensitivity was 100% (95% C.I. [90.5-100]) and the diagnostic specificity was 95.2% (95% C.I. [76.2-99.9]). The repeatability (accordance) and reproducibility (concordance) were 100% for seropositive samples but were lower for two of the seronegative samples (45% and 89% respectively). The analytical sensitivity, evaluated by testing positive sera at increasing dilutions was better for the BT LFT compared to some commercial ELISAs. Seroconversion of an infected sheep was detected at 4 days post infection. Analytical specificity was impaired by cross-reactions observed with some of the samples seropositive for Epizootic Haemorrhagic Disease Virus (EHDV). The agreement (Cohen's kappa) between the LFT and a commercial BT competitive ELISA was 0.79 (95% CI [0.62-0.95]). Based on these results, it can be concluded that the BT LFT device is a rapid and sensitive first-line serological test that can be used in the field, especially in areas endemic for the disease where there is a lack of diagnostic facilities. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Exploration of Analysis Methods for Diagnostic Imaging Tests: Problems with ROC AUC and Confidence Scores in CT Colonography

    PubMed Central

    Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.

    2014-01-01

    Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643

  17. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    PubMed

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  18. Knowledge and Adherence to the National Guidelines for Malaria Diagnosis in Pregnancy among Health-Care Providers and Drug-Outlet Dispensers in Rural Western Kenya.

    PubMed

    Riley, Christina; Dellicour, Stephanie; Ouma, Peter; Kioko, Urbanus; Omar, Ahmeddin; Kariuki, Simon; Ng'ang'a, Zipporah; Desai, Meghna; Buff, Ann M; Gutman, Julie R

    2018-05-01

    Prompt diagnosis and effective treatment of acute malaria in pregnancy (MiP) is important for the mother and fetus; data on health-care provider adherence to diagnostic guidelines in pregnancy are limited. From September to November 2013, a cross-sectional survey was conducted in 51 health facilities and 39 drug outlets in Western Kenya. Provider knowledge of national diagnostic guidelines for uncomplicated MiP were assessed using standardized questionnaires. The use of parasitologic testing was assessed in health facilities via exit interviews with febrile women of childbearing age and in drug outlets via simulated-client scenarios, posing as pregnant women or their spouses. Overall, 93% of providers tested for malaria or accurately described signs and symptoms consistent with clinical malaria. Malaria was parasitologically confirmed in 77% of all patients presenting with febrile illness at health facilities and 5% of simulated clients at drug outlets. Parasitological testing was available in 80% of health facilities; 92% of patients evaluated at these facilities were tested. Only 23% of drug outlets had malaria rapid diagnostic tests (RDTs); at these outlets, RDTs were offered in 17% of client simulations. No differences were observed in testing rates by pregnancy trimester. The study highlights gaps among health providers in diagnostic knowledge and practice related to MiP, and the lack of malaria diagnostic capacity, particularly in drug outlets. The most important factor associated with malaria testing of pregnant women was the availability of diagnostics at the point of service. Interventions that increase the availability of malaria diagnostic services might improve malaria case management in pregnant women.

  19. Measurement of hepatic functional mass by means of 13C-methacetin and 13C-phenylalanine breath tests in chronic liver disease: Comparison with Child-Pugh score and serum bile acid levels

    PubMed Central

    Festi, D.; Capodicasa, S.; Sandri, L.; Colaiocco-Ferrante, L.; Staniscia, T.; Vitacolonna, E.; Vestito, A.; Simoni, P.; Mazzella, G.; Portincasa, P.; Roda, E.; Colecchia, A.

    2005-01-01

    AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels. METHODS: One hundred and forty patients (50 HCV- related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated. RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids. Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test. CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients. PMID:15609414

  20. Utility of dengue NS1 antigen rapid diagnostic test for use in difficult to reach areas and its comparison with dengue NS1 ELISA and qRT-PCR.

    PubMed

    Shukla, Mohan K; Singh, Neeru; Sharma, Ravendra K; Barde, Pradip V

    2017-07-01

    The objective of this study was to demonstrate the utility of dengue virus (DENV) non structural protein 1 (NS1) based rapid diagnostic test (RDT) for use in tribal and difficult to reach areas for early dengue (DEN) diagnosis in acute phase patients and evaluate its sensitivity and specificity against DENV NS1 enzyme linked immune sorbent assay (ELISA) and real time reverse transcriptase polymerase chain reaction (qRT-PCR). The DENV NS1 RDT was used for preliminary diagnosis during outbreaks in difficult to reach rural and tribal areas. The diagnosis was confirmed by DENV NS1 ELISA in the laboratory. The samples were also tested and serotyped by qRT-PCR. The results were evaluated using statistical tests. The DENV NS1 RDT showed 99.2% sensitivity and 96.0% specificity when analyzed using DENV NS1 ELISA as standard. The specificity and sensitivity of the RDT when compared with qRT-PCR was 93.6% and 91.1%, respectively. The serotype specific evaluation showed more than 90% sensitivity and specificity for DENV-1, 2, and 3. The RDT proved a good diagnostic tool in difficult to reach rural and tribal areas. Further evaluation studies with different commercially available RDTs in different field conditions are essential, that will help clinicians and patients for treatment and programme managers for timely intervention. © 2017 Wiley Periodicals, Inc.

  1. The accuracy and cost-effectiveness of strategies used to identify peripheral artery disease among patients with diabetic foot ulcers.

    PubMed

    Barshes, Neal R; Flores, Everardo; Belkin, Michael; Kougias, Panos; Armstrong, David G; Mills, Joseph L

    2016-12-01

    Patients with diabetic foot ulcers (DFUs) should be evaluated for peripheral artery disease (PAD). We sought to estimate the overall diagnostic accuracy for various strategies that are used to identify PAD in this population. A Markov model with probabilistic and deterministic sensitivity analyses was used to simulate the clinical events in a population of 10,000 patients with diabetes. One of 14 different diagnostic strategies was applied to those who developed DFUs. Baseline data on diagnostic accuracy of individual noninvasive tests were based on a meta-analysis of previously reported studies. The overall sensitivity and cost-effectiveness of the 14 strategies were then compared. The overall sensitivity of various combinations of diagnostic testing strategies ranged from 32.6% to 92.6%. Cost-effective strategies included ankle-brachial indices for all patients; skin perfusion pressures (SPPs) or toe-brachial indices (TBIs) for all patients; and SPPs or TBIs to corroborate normal pulse examination findings, a strategy that lowered leg amputation rates by 36%. Strategies that used noninvasive vascular testing to investigate only abnormal pulse examination results had low overall diagnostic sensitivity and were weakly dominated in cost-effectiveness evaluations. Population prevalence of PAD did not alter strategy ordering by diagnostic accuracy or cost-effectiveness. TBIs or SPPs used uniformly or to corroborate a normal pulse examination finding are among the most sensitive and cost-effective strategies to improve the identification of PAD among patients presenting with DFUs. These strategies may significantly reduce leg amputation rates with only modest increases in cost. Published by Elsevier Inc.

  2. Evaluation of Physical Examination Tests for Thumb Basal Joint Osteoarthritis

    PubMed Central

    Model, Zina; Liu, Andrew Y.; Kang, Lana; Wolfe, Scott W.; Burket, Jayme C.; Lee, Steve K.

    2016-01-01

    Background: We compare the ability of 3 diagnostic tests to reproduce the pain of basilar joint arthritis (BJA): the grind test, the lever test (grasping the first metacarpal just distal to the basal joint and shucking back and forth in radial and ulnar directions), and the metacarpophalangeal extension test. Methods: Sixty-two patients with thumb BJA were enrolled. The 3 tests were performed in a random order on both hands of each patient. Prior to testing, patients reported their typical pain level and subsequently rated their pain after each test on a 0 to 10 scale, also specifying the extent to which the test reproduced their thumb pain (fully, partially, not at all). All patients had radiographs that displayed basal joint arthritis. A test was defined as positive for BJA if pain produced was greater than 0. Sensitivity and specificity for each test were calculated using the patients’ history of pain localized to the basal joint and BJA diagnosis on radiographs as the gold standard. Results: The lever test produced the greatest level of pain and best reproduced the presenting pain. The lever test also had the highest sensitivity, high specificity, and the lowest false-negative rate. The grind test had the lowest sensitivity, highest specificity, and highest false-negative rate. Conclusions: The lever test was the diagnostic test that best reproduced the pain caused by thumb basal joint osteoarthritis. We recommend using the lever physical examination test when evaluating the patient with suspected basal joint osteoarthritis. The often-quoted grind test is of limited diagnostic value. PMID:27418899

  3. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    PubMed

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  4. Development of life prediction capabilities for liquid propellant rocket engines. Post-fire diagnostic system for the SSME system architecture study

    NASA Technical Reports Server (NTRS)

    Gage, Mark; Dehoff, Ronald

    1991-01-01

    This system architecture task (1) analyzed the current process used to make an assessment of engine and component health after each test or flight firing of an SSME, (2) developed an approach and a specific set of objectives and requirements for automated diagnostics during post fire health assessment, and (3) listed and described the software applications required to implement this system. The diagnostic system described is a distributed system with a database management system to store diagnostic information and test data, a CAE package for visual data analysis and preparation of plots of hot-fire data, a set of procedural applications for routine anomaly detection, and an expert system for the advanced anomaly detection and evaluation.

  5. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever

    PubMed Central

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-01-01

    Background Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. Objectives To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. Selection criteria We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Data collection and analysis Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Main results Thirty-seven studies met the inclusion criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence rates in the study populations ranged from 1% to 75% (median prevalence 24%, interquartile range (IQR) 11% to 46%). The included studies evaluated 16 different RDTs, and 16 studies compared two or more different RDTs. Only three studies used the Grade 1 reference standard, and only 11 studies recruited unselected febrile patients. Most included studies were from Asia, with five studies from sub-Saharan Africa. All of the RDTs were designed to detect S.Typhi infection only. Most studies evaluated three RDTs and their variants: TUBEX in 14 studies; Typhidot (Typhidot, Typhidot-M, and TyphiRapid-Tr02) in 22 studies; and the Test-It Typhoid immunochromatographic lateral flow assay, and its earlier prototypes (dipstick, latex agglutination) developed by the Royal Tropical Institute, Amsterdam (KIT) in nine studies. Meta-analyses showed an average sensitivity of 78% (95% confidence interval (CI) 71% to 85%) and specificity of 87% (95% CI 82% to 91%) for TUBEX; and an average sensitivity of 69% (95% CI 59% to 78%) and specificity of 90% (95% CI 78% to 93%) for all Test-It Typhoid and prototype tests (KIT). Across all forms of the Typhidot test, the average sensitivity was 84% (95% CI 73% to 91%) and specificity was 79% (95% CI 70% to 87%). When we based the analysis on the 13 studies of the Typhidot test that either reported indeterminate test results or where the test format means there are no indeterminate results, the average sensitivity was 78% (95% CI 65% to 87%) and specificity was 77% (95% CI 66% to 86%). We did not identify any difference in either sensitivity or specificity between TUBEX, Typhidot, and Test-it Typhoid tests when based on comparison to the 13 Typhidot studies where indeterminate results are either reported or not applicable. If TUBEX and Test-it Typhoid are compared to all Typhidot studies, the sensitivity of Typhidot was higher than Test-it Typhoid (15% (95% CI 2% to 28%), but other comparisons did not show a difference at the 95% level of CIs. In a hypothetical cohort of 1000 patients presenting with fever where 30% (300 patients) have enteric fever, on average Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results will miss the diagnosis in 66 patients with enteric fever, TUBEX will miss 66, and Test-It Typhoid and prototype (KIT) tests will miss 93. In the 700 people without enteric fever, the number of people incorrectly diagnosed with enteric fever would be 161 with Typhidot tests, 91 with TUBEX, and 70 with Test-It Typhoid and prototype (KIT) tests. The CIs around these estimates were wide, with no difference in false positive results shown between tests. The quality of the data for each study was evaluated using a standardized checklist called QUADAS-2. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. Authors' conclusions In 37 studies that evaluated the diagnostic accuracy of RDTs for enteric fever, few studies were at a low risk of bias. The three main RDT tests and variants had moderate diagnostic accuracy. There was no evidence of a difference between the average sensitivity and specificity of the three main RDT tests. More robust evaluations of alternative RDTs for enteric fever are needed. The accuracy of rapid diagnostic tests for detecting typhoid and paratyphoid (enteric) fever Cochrane researchers assessed the accuracy of commercially-available rapid diagnostic tests and their prototypes (including TUBEX, Typhidot, Typhidot-M, Test-it Typhoid, and other tests) for detecting typhoid and paratyphoid (enteric) fever in people living in countries where the estimated number of individuals with the disease at any one time is greater than 10 per 100,000 population. If accurate, they could replace the current World Health Organization (WHO)-recommended diagnostic test: culture (growing the bacteria that causes the infection from a patient’s blood or bone marrow). Background Typhoid fever and paratyphoid fever are infections caused by the bacteria Salmonella Typhi and Salmonella Paratyphi A respectively. The term ‘enteric fever’ is used to describe both infections. Enteric fever can be difficult to diagnose as the signs and symptoms are similar to those of other infectious diseases that cause fever such as malaria. The recommended test to confirm if a person has enteric fever is to grow the Salmonella from their blood. It takes at least 48 hours to give a result, so cannot help healthcare workers make a diagnosis the same day the blood culture is taken. Blood cultures may give a negative result even though a person has enteric fever. The test also requires a laboratory and trained staff, which are often unavailable in communities where enteric fever is common. Rapid diagnostic tests (RDTs) are designed to be easy to use, and to deliver a quick result without the need for a blood culture laboratory. The cost of an enteric fever RDT would be significantly less than a blood culture, and requires less training to perform. Study characteristics Cochrane researchers searched the available literature up to 4 March 2016 and included 37 studies. Most studies recruited participants from South Asia. Most participants were adults, with 22 studies including children. All of the RDTs evaluated detected Salmonella Typhi (typhoid fever) only. Quality of the evidence The Cochrane researchers evaluated the quality of the data for each study using a standardized checklist called QUADAS-2. High quality studies that compared different types of RDT in the same patients were few in number. Two-thirds of the included studies did not evaluate the RDTs in the context of patients who are typically tested for the disease. Many studies utilized a particular study design (a case control study) which risks overestimating RDT accuracy. In the studies evaluating the Typhidot RDT, it was often unclear how many test results were indeterminate, when the test cannot distinguish a current episode of infection from a previous disease episode. Overall, the certainty of the evidence in the studies that evaluated enteric fever RDTs was low. Key results Sensitivity indicates the percentage of patients with a positive test result who are correctly diagnosed with disease. Specificity indicates the percentage of patients who are correctly identified as not having disease. TUBEX showed an average sensitivity of 78% and specificity of 87%. Typhidot studies, grouped together to include Typhidot, Typhidot-M, and TyphiRapid-Tr02, showed an average sensitivity of 84% and specificity of 79%. When Typhidot studies with clear reporting of indeterminate results are considered, the average sensitivity and specificity of Typhidot was 78% and 77% respectively. Test-It Typhoid and prototypes (KIT) showed an average sensitivity of 69% and specificity of 90%. Based on these results, in 1000 patients with fever where 30% (300 patients) have enteric fever, we would expect Typhidot tests reporting indeterminate results or where tests do not produce indeterminate results to, on average, miss the diagnosis (give a false negative result) in 66 patients with enteric fever, TUBEX to miss 66, and Test-It Typhoid and prototypes (KIT) to miss 93. In the 700 people without enteric fever, the number of people incorrectly given a diagnosis of enteric fever (a false positive result) would be on average 161 with these Typhidot tests, 91 with TUBEX, and 70 with the Test-It Typhoid and prototypes (KIT). These differences in the number of false negative and false positive results in patients from the different tests are not statistically important. The RDTs evaluated are not sufficiently accurate to replace blood culture as a diagnostic test for enteric fever. PMID:28545155

  6. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  7. Un Test contrastif oral pour l'evaluation des difficultes lexicales dans l'apprentissage de l'anglais L2 (An Oral Contrastive Test for the Evaluation of Lexical Difficulties in Learning English as a Second Language).

    ERIC Educational Resources Information Center

    Haeusser, Christiane

    1978-01-01

    The test described here is a particular type of diagnostic test; it is part of a series of tests designed to explore systematically areas of potential lexical difficulty in the English language for French-speaking students of English. The lexical units are considered under their formal, morphological, syntactic and semantic aspects. The test has…

  8. Cost-effectiveness of alternative test strategies for the diagnosis of coronary artery disease.

    PubMed

    Garber, A M; Solomon, N A

    1999-05-04

    The appropriate roles for several diagnostic tests for coronary disease are uncertain. To evaluate the cost-effectiveness of alternative approaches to diagnosis of coronary disease. Meta-analysis of the accuracy of alternative diagnostic tests plus decision analysis to assess the health outcomes and costs of alternative diagnostic strategies for patients at intermediate pretest risk for coronary disease. Studies of test accuracy that met inclusion criteria; published information on treatment effectiveness and disease prevalence. Men and women 45, 55, and 65 years of age with a 25% to 75% pretest risk for coronary disease. 30 years. Societal. Diagnostic strategies were initial angiography and initial testing with one of five noninvasive tests--exercise treadmill testing, planar thallium imaging, single-photon emission computed tomography (SPECT), stress echocardiography, and positron emission tomography (PET)--followed by coronary angiography if noninvasive test results were positive. Testing was followed by observation, medical treatment, or revascularization. Life-years, quality-adjusted life-years (QALYs), costs, and costs per QALY. Life expectancy varied little with the initial diagnostic test; for a 55-year-old man, the best-performing test increased life expectancy by 7 more days than the worst-performing test. More sensitive tests increased QALYs more. Echocardiography improved health outcomes and reduced costs relative to stress testing and planar thallium imaging. The incremental cost-effectiveness ratio was $75,000/QALY for SPECT relative to echocardiography and was greater than $640,000 for PET relative to SPECT. Compared with SPECT, immediate angiography had an incremental cost-effectiveness ratio of $94,000/QALY. Qualitative findings varied little with age, sex, pretest probability of disease, or the test indeterminancy rate. Results varied most with sensitivity to severe coronary disease. Echocardiography, SPECT, and immediate angiography are cost-effective alternatives to PET and other diagnostic approaches. Test selection should reflect local variation in test accuracy.

  9. Immunodiagnosis of toxocarosis in humans: evaluation of a new enzyme-linked immunosorbent assay kit.

    PubMed Central

    Jacquier, P; Gottstein, B; Stingelin, Y; Eckert, J

    1991-01-01

    Excretory/secretory (E/S) antigen derived from second-stage larvae of Toxocara canis maintained in defined medium in vitro has been well established worldwide for the immunodiagnosis of human toxocarosis by enzyme-linked immunosorbent assay. Such an enzyme-linked immunosorbent assay, based on the detection of human anti-T. canis (E/S antigen) serum immunoglobulin G, has recently been commercialized by Biokema-Affinity Products (Crissier-Lausanne, Switzerland). This commercial test kit was evaluated with regard to its application in a routine diagnostic laboratory and the reliability of the results. Of 78 patients with suspected clinical toxocarosis, 71 had anti-T. canis antibodies (positive serological result) corresponding to a diagnostic sensitivity of 91%; 14% of serum samples (n = 199) from patients with protozoan or with helminthic infections also showed positive reactions mainly related to infections with Trichinella, Strongyloides, and Fasciola species. An epidemiological study with 1,000 serum samples from randomly selected healthy blood donors and children in Switzerland demonstrated a seroprevalence of 2.7%. The test kit under evaluation had an overall diagnostic sensitivity of 91% and a relative specificity of 86%, the latter being related to some protozoan and helminthic infections. Because of the scarcity of such infections, potential cross-reactivity does not play a major role under the conditions found in the middle part of Europe. In conclusion, the application of the test kit provided for use in this study can be recommended for routine diagnostic use. PMID:1774303

  10. Physical examination tests for the diagnosis of posterior cruciate ligament rupture: a systematic review.

    PubMed

    Kopkow, Christian; Freiberg, Alice; Kirschner, Stephan; Seidler, Andreas; Schmitt, Jochen

    2013-11-01

    Systematic literature review. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of posterior cruciate ligament (PCL) tear. Rupture of the PCL is a severe knee injury that can lead to delayed rehabilitation, instability, or chronic knee pathologies. To our knowledge, there is currently no systematic review of studies on the diagnostic accuracy of clinical examination tests to evaluate the integrity of the PCL. A comprehensive systematic literature search was conducted in MEDLINE from 1946, Embase from 1974, and the Allied and Complementary Medicine Database from 1985 until April 30, 2012. Studies were considered eligible if they compared the results of physical examination tests performed in the context of a PCL physical examination to those of a reference standard (arthroscopy, arthrotomy, magnetic resonance imaging). Methodological quality assessment was performed by 2 independent reviewers using the revised version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The search strategy revealed 1307 articles, of which 11 met the inclusion criteria for this review. In these studies, 11 different physical examination tests were identified. Due to differences in study types, different patient populations, and methodological quality, meta-analysis was not indicated. Presently, most physical examination tests have not been evaluated sufficiently enough to be confident in their ability to either confirm or rule out a PCL tear. The diagnostic accuracy of physical examination tests to assess the integrity of the PCL is largely unknown. There is a strong need for further research in this area. Level of Evidence Diagnosis, level 3a.

  11. Test of memory malingering (TOMM) trial 1 as a screening measure for insufficient effort.

    PubMed

    O'Bryant, Sid E; Engel, Lisa R; Kleiner, Jennifer S; Vasterling, Jennifer J; Black, F William

    2007-05-01

    The identification of insufficient effort is critical to neuropsychological evaluation, and several existing instruments assess effort on neuropsychological tasks. Yet instruments designed to detect insufficient effort are underutilized in standard neuropsychological assessments, perhaps in part because they typically require significant administration time and are, therefore, not ideally suited to screening contexts. The Test of Memory Malingering (TOMM) is a commonly administered, well-validated symptom validity test. This study evaluates the utility of TOMM Trial 1 as a relatively brief screening measure of insufficient effort. Results suggest that TOMM Trial 1 demonstrates high diagnostic accuracy and is a viable option for screening insufficient effort. Diagnostic accuracy estimates are presented for a range of base rates. The need for more comprehensive SVT assessment in most clinical and forensic situation is discussed.

  12. Comparative Evaluation of 11 Commercialized Rapid Diagnostic Tests for Detecting Trypanosoma cruzi Antibodies in Serum Banks in Areas of Endemicity and Nonendemicity

    PubMed Central

    Albajar-Viñas, Pedro; Wilkins, Patricia P.; Nieto, Javier; Leiby, David A.; Paris, Luc; Scollo, Karenina; Flórez, Carolina; Guzmán-Bracho, Carmen; Luquetti, Alejandro O.; Calvo, Nidia; Tadokoro, Kenji; Saez-Alquezar, Amadeo; Palma, Pedro Pablo; Martin, Miguel

    2014-01-01

    Chagas disease is one of the main public health issues in Latin America. Increasingly during the past few decades, Trypanosoma cruzi infection has been detected in North America, Europe, and the Western Pacific, mainly as a result of population movement. The limited availability of rapid serological diagnostic tests hinders rapid diagnosis and early treatment in areas of endemicity and nonendemicity. In collaboration with 11 national reference laboratories (NRLs) from different geographical areas, we evaluated the performances of commercialized serological rapid diagnostic tests (RDT) for T. cruzi infection. Eleven commercialized T. cruzi infection RDTs were evaluated on a total of 474 samples extensively tested with at least three different techniques for Chagas disease, maintained at controlled low temperatures, and stored in the serum banks of the 11 NRLs. We measured the sensitivity, specificity, and concordance of each RDT and provided an additional questionnaire to evaluate its ease of use. The selected RDTs in this study were performed under controlled laboratory conditions. Out of the 11 RDTs, we found 8 of them to be useful, with the cassette format favored over the strip. We did not observe significant differences in RDT performances in the different regions. Overall, the performance results were lower than those disclosed by the manufacturers. The results of this evaluation validate the possibility of using RDTs to diagnose Chagas disease, thereby decreasing the time to treatment at a primary health care facility for patients who are willing to be treated. Further studies should be conducted in the laboratory and in the field to confirm these data, expressly to evaluate reproducibility in resource-limited settings, or using whole blood in clinical settings in areas of endemicity and nonendemicity. PMID:24808239

  13. Using a web-based application to define the accuracy of diagnostic tests when the gold standard is imperfect.

    PubMed

    Lim, Cherry; Wannapinij, Prapass; White, Lisa; Day, Nicholas P J; Cooper, Ben S; Peacock, Sharon J; Limmathurotsakul, Direk

    2013-01-01

    Estimates of the sensitivity and specificity for new diagnostic tests based on evaluation against a known gold standard are imprecise when the accuracy of the gold standard is imperfect. Bayesian latent class models (LCMs) can be helpful under these circumstances, but the necessary analysis requires expertise in computational programming. Here, we describe open-access web-based applications that allow non-experts to apply Bayesian LCMs to their own data sets via a user-friendly interface. Applications for Bayesian LCMs were constructed on a web server using R and WinBUGS programs. The models provided (http://mice.tropmedres.ac) include two Bayesian LCMs: the two-tests in two-population model (Hui and Walter model) and the three-tests in one-population model (Walter and Irwig model). Both models are available with simplified and advanced interfaces. In the former, all settings for Bayesian statistics are fixed as defaults. Users input their data set into a table provided on the webpage. Disease prevalence and accuracy of diagnostic tests are then estimated using the Bayesian LCM, and provided on the web page within a few minutes. With the advanced interfaces, experienced researchers can modify all settings in the models as needed. These settings include correlation among diagnostic test results and prior distributions for all unknown parameters. The web pages provide worked examples with both models using the original data sets presented by Hui and Walter in 1980, and by Walter and Irwig in 1988. We also illustrate the utility of the advanced interface using the Walter and Irwig model on a data set from a recent melioidosis study. The results obtained from the web-based applications were comparable to those published previously. The newly developed web-based applications are open-access and provide an important new resource for researchers worldwide to evaluate new diagnostic tests.

  14. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network

    PubMed Central

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-01

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method. PMID:26761006

  15. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network.

    PubMed

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-08

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method.

  16. Next generation diagnostic molecular pathology: critical appraisal of quality assurance in Europe.

    PubMed

    Dubbink, Hendrikus J; Deans, Zandra C; Tops, Bastiaan B J; van Kemenade, Folkert J; Koljenović, S; van Krieken, Han J M; Blokx, Willeke A M; Dinjens, Winand N M; Groenen, Patricia J T A

    2014-06-01

    Tumor evaluation in pathology is more and more based on a combination of traditional histopathology and molecular analysis. Due to the rapid development of new cancer treatments that specifically target aberrant proteins present in tumor cells, treatment decisions are increasingly based on the molecular features of the tumor. Not only the number of patients eligible for targeted precision medicine, but also the number of molecular targets per patient and tumor type is rising. Diagnostic molecular pathology, the discipline that determines the molecular aberrations present in tumors for diagnostic, prognostic or predictive purposes, is faced with true challenges. The laboratories have to meet the need of comprehensive molecular testing using only limited amount of tumor tissue, mostly fixed in formalin and embedded in paraffin (FFPE), in short turnaround time. Choices must be made for analytical methods that provide accurate, reliable and cost-effective results. Validation of the test procedures and results is essential. In addition, participation and good performance in internal (IQA) and external quality assurance (EQA) schemes is mandatory. In this review, we critically evaluate the validation procedure for comprehensive molecular tests as well as the organization of quality assurance and assessment of competence of diagnostic molecular pathology laboratories within Europe. Copyright © 2014 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  17. Bayesian estimation of diagnostic sensitivity and specificity of a nervous necrosis virus antibody ELISA.

    PubMed

    Jaramillo, Diana; Dürr, Salome; Hick, Paul; Whittington, Richard

    2016-01-01

    Diagnosis of nervous necrosis virus (NNV) infection in susceptible fish species is mostly performed post-mortem due to the neurotropism of the causative agent and the only validated diagnostic assays require samples from brain and retinal tissue. However, a non-lethal alternative to test for exposure of fish to NNV is needed. An indirect ELISA for the detection of anti-NNV antibodies in was recently developed and evaluated to detect responses in the sera from immunized fish. For this study, we assessed the accuracy of the assay at detecting specific antibodies from naturally exposed fish using field samples from populations with differing infection status. We applied a Bayesian model, using RTqPCR as a second test. Median estimates of the diagnostic sensitivity and specificity of the VNN ELISA were 81.8% and 86.7%, respectively. We concluded that the assay was fit for the purpose of identifying animals in naturally exposed populations. With further evaluation in larger populations the test might be used to inform implementation of control measures, and for estimating infection prevalence to facilitate risk analysis. To our knowledge this is the first report on the diagnostic accuracy of an antibody ELISA for an infectious disease in finfish. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Cost-effectiveness of using a molecular diagnostic test to improve preoperative diagnosis of thyroid cancer.

    PubMed

    Najafzadeh, Mehdi; Marra, Carlo A; Lynd, Larry D; Wiseman, Sam M

    2012-12-01

    Fine-needle aspiration biopsy (FNAB) is a safe and inexpensive diagnostic procedure for evaluating thyroid nodules.Up to 25% of the results from an FNAB, however, may not be diagnostic or may be indeterminate, leading to a subsequent diagnostic thyroid surgery. A new molecularly based diagnostic test could potentially reduce indeterminate cytological results and, with high accuracy, provide a definitive diagnosis for cancer in thyroid nodules. The aim of the study was to estimate the cost-effectiveness of utilizing a molecular diagnostic (DX) test as an adjunct to FNAB, compared with NoDX, to improve the preoperative diagnosis of thyroid nodules. We constructed a patient-level simulation model to estimate the clinical and economic outcomes of using a DX test compared with current practice (NoDX) for the diagnosis of thyroid nodules. By using a cost-effectiveness framework, we measured incremental clinical benefits in terms of quality-adjusted life-years and incremental costs over a 10-year time horizon. Assuming 95% sensitivity and specificity of the Dx test when used as an adjunct to FNAB, the utilization of the DX test resulted in a gain of 0.046 quality-adjusted life-years (95% confidence interval 0.019-0.078) and a saving of $1087 (95% confidence interval $691-$1533) in direct costs per patient. If the cost of the Dx test is less than $1087 per test, we expect to save quality-adjusted life-years and reduce costs when it is utilized. Sensitivity of the DX test, compared with specificity, had a larger influence on the overall outcomes. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  19. Evaluation of a 5-Marker Blood Test for Colorectal Cancer Early Detection in a Colorectal Cancer Screening Setting.

    PubMed

    Werner, Simone; Krause, Friedemann; Rolny, Vinzent; Strobl, Matthias; Morgenstern, David; Datz, Christian; Chen, Hongda; Brenner, Hermann

    2016-04-01

    In initial studies that included colorectal cancer patients undergoing diagnostic colonoscopy, we had identified a serum marker combination able to detect colorectal cancer with similar diagnostic performance as fecal immunochemical test (FIT). In this study, we aimed to validate the results in participants of a large colorectal cancer screening study conducted in the average-risk, asymptomatic screening population. We tested serum samples from 1,200 controls, 420 advanced adenoma patients, 4 carcinoma in situ patients, and 36 colorectal cancer patients with a 5-marker blood test [carcinoembryonic antigen (CEA)+anti-p53+osteopontin+seprase+ferritin]. The diagnostic performance of individual markers and marker combinations was assessed and compared with stool test results. AUCs for the detection of colorectal cancer and advanced adenomas with the 5-marker blood test were 0.78 [95% confidence interval (CI), 0.68-0.87] and 0.56 (95% CI, 0.53-0.59), respectively, which now is comparable with guaiac-based fecal occult blood test (gFOBT) but inferior to FIT. With cutoffs yielding specificities of 80%, 90%, and 95%, the sensitivities for the detection of colorectal cancer were 64%, 50%, and 42%, and early-stage cancers were detected as well as late-stage cancers. For osteopontin, seprase, and ferritin, the diagnostic performance in the screening setting was reduced compared with previous studies in diagnostic settings while CEA and anti-p53 showed similar diagnostic performance in both settings. Performance of the 5-marker blood test under screening conditions is inferior to FIT even though it is still comparable with the performance of gFOBT. CEA and anti-p53 could contribute to the development of a multiple marker blood-based test for early detection of colorectal cancer. ©2015 American Association for Cancer Research.

  20. Comparing the economic and health benefits of different approaches to diagnosing Clostridium difficile infection.

    PubMed

    Bartsch, Sarah M; Umscheid, Craig A; Nachamkin, Irving; Hamilton, Keith; Lee, Bruce Y

    2015-01-01

    Accurate diagnosis of Clostridium difficile infection (CDI) is essential to effectively managing patients and preventing transmission. Despite the availability of several diagnostic tests, the optimal strategy is debatable and their economic values are unknown. We modified our previously existing C. difficile simulation model to determine the economic value of different CDI diagnostic approaches from the hospital perspective. We evaluated four diagnostic methods for a patient suspected of having CDI: 1) toxin A/B enzyme immunoassay, 2) glutamate dehydrogenase (GDH) antigen/toxin AB combined in one test, 3) nucleic acid amplification test (NAAT), and 4) GDH antigen/toxin AB combination test with NAAT confirmation of indeterminate results. Sensitivity analysis varied the proportion of those tested with clinically significant diarrhoea, the probability of CDI, NAAT cost and CDI treatment delay resulting from a false-negative test, length of stay and diagnostic sensitivity and specificity. The GDH/toxin AB plus NAAT approach leads to the timeliest treatment with the fewest unnecessary treatments given, resulted in the best bed management and generated the lowest cost. The NAAT-alone approach also leads to timely treatment. The GDH/toxin AB diagnostic (without NAAT confirmation) approach resulted in a large number of delayed treatments, but results in the fewest secondary colonisations. Results were robust to the sensitivity analysis. Choosing the right diagnostic approach is a matter of cost and test accuracy. GDH/toxin AB plus NAAT diagnosis led to the timeliest treatment and was the least costly. Copyright © 2014 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  1. Rapid molecular diagnostics for multi-drug resistant tuberculosis in India.

    PubMed

    Ramachandran, Rajeswari; Muniyandi, M

    2018-03-01

    Rapid molecular diagnostic methods help in the detection of TB and Rifampicin resistance. These methods detect TB early, are accurate and play a crucial role in reducing the burden of drug resistant tuberculosis. Areas covered: This review analyses rapid molecular diagnostic tools used in the diagnosis of MDR-TB in India, such as the Line Probe Assay and GeneXpert. We have discussed the burden of MDR-TB and the impact of recent diagnostic tools on case detection and treatment outcomes. This review also discusses the costs involved in establishing these new techniques in India. Expert commentary: Molecular methods have considerable advantages for the programmatic management of drug resistant TB. These include speed, standardization of testing, potentially high throughput and reduced laboratory biosafety requirements. There is a desperate need for India to adopt modern, rapid, molecular tools with point-of-care tests being currently evaluated. New molecular diagnostic tests appear to be cost effective and also help in detecting missing cases. There is enough evidence to support the scaling up of these new tools in India.

  2. Commentary: Reducing diagnostic errors: another role for checklists?

    PubMed

    Winters, Bradford D; Aswani, Monica S; Pronovost, Peter J

    2011-03-01

    Diagnostic errors are a widespread problem, although the true magnitude is unknown because they cannot currently be measured validly. These errors have received relatively little attention despite alarming estimates of associated harm and death. One promising intervention to reduce preventable harm is the checklist. This intervention has proven successful in aviation, in which situations are linear and deterministic (one alarm goes off and a checklist guides the flight crew to evaluate the cause). In health care, problems are multifactorial and complex. A checklist has been used to reduce central-line-associated bloodstream infections in intensive care units. Nevertheless, this checklist was incorporated in a culture-based safety program that engaged and changed behaviors and used robust measurement of infections to evaluate progress. In this issue, Ely and colleagues describe how three checklists could reduce the cognitive biases and mental shortcuts that underlie diagnostic errors, but point out that these tools still need to be tested. To be effective, they must reduce diagnostic errors (efficacy) and be routinely used in practice (effectiveness). Such tools must intuitively support how the human brain works, and under time pressures, clinicians rarely think in conditional probabilities when making decisions. To move forward, it is necessary to accurately measure diagnostic errors (which could come from mapping out the diagnostic process as the medication process has done and measuring errors at each step) and pilot test interventions such as these checklists to determine whether they work.

  3. A concise evidence-based physical examination for diagnosis of acromioclavicular joint pathology: a systematic review.

    PubMed

    Krill, Michael K; Rosas, Samuel; Kwon, KiHyun; Dakkak, Andrew; Nwachukwu, Benedict U; McCormick, Frank

    2018-02-01

    The clinical examination of the shoulder joint is an undervalued diagnostic tool for evaluating acromioclavicular (AC) joint pathology. Applying evidence-based clinical tests enables providers to make an accurate diagnosis and minimize costly imaging procedures and potential delays in care. The purpose of this study was to create a decision tree analysis enabling simple and accurate diagnosis of AC joint pathology. A systematic review of the Medline, Ovid and Cochrane Review databases was performed to identify level one and two diagnostic studies evaluating clinical tests for AC joint pathology. Individual test characteristics were combined in series and in parallel to improve sensitivities and specificities. A secondary analysis utilized subjective pre-test probabilities to create a clinical decision tree algorithm with post-test probabilities. The optimal special test combination to screen and confirm AC joint pathology combined Paxinos sign and O'Brien's Test, with a specificity of 95.8% when performed in series; whereas, Paxinos sign and Hawkins-Kennedy Test demonstrated a sensitivity of 93.7% when performed in parallel. Paxinos sign and O'Brien's Test demonstrated the greatest positive likelihood ratio (2.71); whereas, Paxinos sign and Hawkins-Kennedy Test reported the lowest negative likelihood ratio (0.35). No combination of special tests performed in series or in parallel creates more than a small impact on post-test probabilities to screen or confirm AC joint pathology. Paxinos sign and O'Brien's Test is the only special test combination that has a small and sometimes important impact when used both in series and in parallel. Physical examination testing is not beneficial for diagnosis of AC joint pathology when pretest probability is unequivocal. In these instances, it is of benefit to proceed with procedural tests to evaluate AC joint pathology. Ultrasound-guided corticosteroid injections are diagnostic and therapeutic. An ultrasound-guided AC joint corticosteroid injection may be an appropriate new standard for treatment and surgical decision-making. II - Systematic Review.

  4. Evaluation and comparison of native and recombinant LipL21 protein-based ELISAs for diagnosis of bovine leptospirosis.

    PubMed

    Joseph, Siju; Thomas, Naicy; Thangapandian, E; Singh, Vijendra P; Verma, Rishendra; Srivastava, S K

    2012-03-01

    A 21-kDa leptospiral lipoprotein (LipL21) was evaluated for its diagnostic potential to detect bovine leptospirosis by ELISA. Both native LipL21 (nLipL21) and recombinant LipL21 (rLipL21) proteins were tested and compared regarding diagnostic efficiency, and no statistically significant difference was observed. The sensitivity of rLipL21 ELISA for 62 microscopic agglutination test (MAT) positive sera was 100% and the specificity with 378 MAT negative sera was 97.09%. Thus, rLipL21 protein-based ELISA could be used as an alternative to MAT for the diagnosis of bovine leptospirosis.

  5. Effects on costs of frontline diagnostic evaluation in patients suspected of angina: coronary computed tomography angiography vs. conventional ischaemia testing.

    PubMed

    Nielsen, Lene H; Olsen, Jens; Markenvard, John; Jensen, Jesper M; Nørgaard, Bjarne L

    2013-05-01

    The aim of this study was to investigate in patients with stable angina the effects on costs of frontline diagnostics by exercise-stress testing (ex-test) vs. coronary computed tomography angiography (CTA). In two coronary units at Lillebaelt Hospital, Denmark, 498 patients were identified in whom either ex-test (n = 247) or CTA (n = 251) were applied as the frontline diagnostic strategy in symptomatic patients with a low-intermediate pre-test probability of coronary artery disease (CAD). During 12 months of follow-up, death, myocardial infarction and costs associated with downstream diagnostic utilization (DTU), treatment, ambulatory visits, and hospitalizations were registered. There was no difference between cohorts in demographic characteristics or the pre-test probability of significant CAD. The mean (SD) age was 56 (11) years; 52% were men; and 96% were at low-intermediate pre-test probability of CAD. All serious cardiac events (n = 3) during follow-up occurred in patients with a negative ex-test result. Mean costs per patient associated with DTU, ambulatory visits, and cardiovascular medication were significantly higher in the ex-test than in the CTA group. The mean (SD) total costs per patient at the end of the follow-up were 14% lower in the CTA group than in the ex-test group, € 1510 (3474) vs. €1777 (3746) (P = 0.03). Diagnostic assessment of symptomatic patients with a low-intermediate probability of CAD by CTA incurred lower costs when compared with the ex-test. These findings need confirmation in future prospective trials.

  6. Parkinson's Disease Diagnostic Observations (PADDO): study rationale and design of a prospective cohort study for early differentiation of parkinsonism.

    PubMed

    van Rumund, Anouke; Aerts, Marjolein B; Esselink, Rianne A J; Meijer, Frederick J A; Verbeek, Marcel M; Bloem, Bastiaan R

    2018-05-16

    Differentiation of Parkinson's disease (PD) from the various types of atypical parkinsonism (AP) such as multiple system atrophy (MSA), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB), corticobasal syndrome (CBS) and vascular parkinsonism (VP), can be challenging, especially early in the disease course when symptoms overlap. A major unmet need in the diagnostic workup of these disorders is a diagnostic tool that differentiates the various disorders, preferably in the earliest disease stages when the clinical presentation is similar. Many diagnostic tests have been evaluated, but their added value was studied mostly in retrospective case-control studies that included patients with a straightforward clinical diagnosis. Here, we describe the design of a prospective cohort study in patients with parkinsonism in an early disease stage who have an uncertain clinical diagnosis. Our aim is to evaluate the diagnostic accuracy of (1) detailed clinical examination by a movement disorder specialist, (2) magnetic resonance imaging (MRI) techniques and (3) cerebrospinal fluid (CSF) biomarkers. Patients with parkinsonism with an uncertain clinical diagnosis and a disease course less than three years will be recruited. Patients will undergo extensive neurological examination, brain MRI including conventional and advanced sequences, and a lumbar puncture. The diagnosis (including level of certainty) will be defined by a movement disorders expert, neuroradiologist and neurochemist based on clinical data, MRI results and CSF results, respectively. The clinical diagnosis after three years' follow-up will serve as the "gold standard" reference diagnosis, based on consensus criteria and as established by two movement disorder specialists (blinded to the test results). Diagnostic accuracy of individual instruments and added value of brain MRI and CSF analysis after evaluation by a movement disorder expert will be calculated, expressed as the change in percentage of individuals that are correctly diagnosed with PD or AP. This study will yield new insights into the diagnostic value of clinical evaluation by a movement disorder specialist, brain MRI and CSF analysis in discriminating PD from AP in early disease stages. The outcome has the potential to help clinicians in choosing the optimal diagnostic strategy for patients with an uncertain clinical diagnosis. NCT01249768, registered November 26 2010.

  7. Evaluation of an Immunocapture-Agglutination Test (Brucellacapt) for Serodiagnosis of Human Brucellosis

    PubMed Central

    Orduña, Antonio; Almaraz, Ana; Prado, Ana; Gutierrez, M. Purificación; Garcia-Pascual, Agustina; Dueñas, Ana; Cuervo, Milagros; Abad, Ramon; Hernández, Beatriz; Lorenzo, Belen; Bratos, Miguel A.; Torres, Antonio Rodriguez

    2000-01-01

    We evaluated the validity and the usefulness of a new test for the diagnosis of human brucellosis based on an immunocapture-agglutination technique. A total of 315 sera from 82 patients with a diagnosis of brucellosis, 157 sera from patients in whom brucellosis was suspected but not confirmed, and 412 sera from people living in rural areas with endemic brucellosis were studied. The seroagglutination test (SAT), Coombs anti-Brucella test, and Brucellacapt test were evaluated. All the initial sera from the 82 patients proved to be positive in Brucellacapt and Coombs tests, while only 75 (91.4%) were positive in the SAT. If a ≥1/160 diagnostic threshold titer was defined for the Brucellacapt test, Coombs test, and SAT, the sensitivities were 95.1, 91.5, and 65.8%, respectively. Taking the same diagnostic threshold titer for the 157 sera from the unconfirmed but suspected patients, the specificities of the Brucellacapt, Coombs, and SAT were 81.5, 96.2, and 100%, respectively; for the 412 control sera, the specificities were 99.0, 99.8, and 100%. The diagnostic efficiency (area below the receiver operating characteristic curve) of Brucellacapt was 0.987852 (95% confidence interval [CI], 0.95109 to 0.99286), very similar to the diagnostic efficiency of the Coombs test (0.97611; 95% CI, 0.94781 to 0.99146) and higher than that of SAT (0.91013; 95% CI, 0.86649 to 0.94317). The results of the Brucellacapt test were compared with those of the Coombs test (correlation coefficient, 0.956; P = 0.000) and SAT (correlation coefficient, 0.866; P = 0.000). The study shows very good correlation between the Brucellacapt and Coombs tests, with a high concordance between titers obtained in the two tests. Nevertheless, lower correlation and concordance were found between the Brucellacapt and Coombs tests when the results for titers of ≥1/160 were compared (0.692; P = 0.000). In acute brucellosis, the Brucellacapt and Coombs tests render positive titers of ≥1/160. When the titers are lower, they increase significantly in the following 30 days, despite the evolution of SAT titers. In contrast, Brucellacapt and Coombs titers are always high (≥1/640) in brucellosis with long evolution, whether SAT titers are higher or lower than 1/160. PMID:11060059

  8. Diagnostics of Polymer Composite Materials and Analysis of Their Production Technology by Using the Method of Acoustic Emission

    NASA Astrophysics Data System (ADS)

    Bashkov, O. V.; Protsenko, A. E.; Bryanskii, A. A.; Romashko, R. V.

    2017-09-01

    The strength properties of glass-fiber-reinforced plastics produced by vacuum and vacuum autoclave molding techniques are studied. Based on acoustic emission data, a method of diagnostic and prediction of the bearing capacity of polymer composite materials by using data from three-point bending tests is developed. The method is based on evaluating changes in the exponent of a power function relating the total acoustic emission to the test stress.

  9. Near patient testing in general practice: a review.

    PubMed Central

    Hilton, S

    1990-01-01

    Until recently, technological advances in general practice have generally been thought of as the applications of microcomputers in practice organization and record keeping. Advances in miniaturization and versatility of diagnostic technology will have a similarly large impact on the way general practitioners practice medicine in the next decade. This article reviews some of the newer tests that are already available to general practitioners, particularly in diagnostic biochemistry and microbiology. Preliminary evaluative work and research studies in general practice are also described. PMID:2107838

  10. Accuracy of biochemical markers for predicting nasogastric tube placement in adults--a systematic review of diagnostic studies.

    PubMed

    Fernandez, Ritin S; Chau, Janita Pak-Chun; Thompson, David R; Griffiths, Rhonda; Lo, Hoi-Shan

    2010-08-01

    The objective of this study was to investigate the diagnostic performance of biochemical tests used to determine placement of nasogastric (NG) tubes after insertion in adults. A systematic review of diagnostic studies was undertaken. A literature search of the bibliographic databases and the World Wide Web was performed to locate original diagnostic studies in English or Chinese on biochemical markers for detecting NG tube location. Studies in which one or more different tests were evaluated with a reference standard, and diagnostic values were reported or could be calculated were included. Two reviewers independently checked all abstracts and full text studies for inclusion criteria. Included studies were assessed for their quality using the QUADAS tool. Study features and diagnostic values were extracted from the included studies. Of the 10 studies included in this review, seven investigated the diagnostic accuracy of pH, one investigated the diagnostic accuracy of pH and bilirubin respectively, two a combination of pH and bilirubin and one a combination of pH, pepsin and trypsin levels in identifying NG tube location. All studies used X-rays as the reference standard for comparison. Pooled results demonstrated that a pH of

  11. Time-Motion Analysis of Four Automated Systems for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by Nucleic Acid Amplification Testing.

    PubMed

    Williams, James A; Eddleman, Laura; Pantone, Amy; Martinez, Regina; Young, Stephen; Van Der Pol, Barbara

    2014-08-01

    Next-generation diagnostics for Chlamydia trachomatis and Neisseria gonorrhoeae are available on semi- or fully-automated platforms. These systems require less hands-on time than older platforms and are user friendly. Four automated systems, the ABBOTT m2000 system, Becton Dickinson Viper System with XTR Technology, Gen-Probe Tigris DTS system, and Roche cobas 4800 system, were evaluated for total run time, hands-on time, and walk-away time. All of the systems evaluated in this time-motion study were able to complete a diagnostic test run within an 8-h work shift, instrument setup and operation were straightforward and uncomplicated, and walk-away time ranged from approximately 90 to 270 min in a head-to-head comparison of each system. All of the automated systems provide technical staff with increased time to perform other tasks during the run, offer easy expansion of the diagnostic test menu, and have the ability to increase specimen throughput. © 2013 Society for Laboratory Automation and Screening.

  12. Ocular Pharmacology of Tear Film, Dry Eye, and Allergic Conjunctivitis.

    PubMed

    Gulati, Shilpa; Jain, Sandeep

    2017-01-01

    Dry Eye Disease (DED) is "a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbance, and tear-film instability with potential damage to the ocular surface." DED comprises two etiologic categories: aqueous-deficient dry eye (ADDE) and evaporative dry eye (EDE). Diagnostic workup of DED should include clinical history, symptom questionnaire, fluorescein TBUT, ocular surface staining grading, Schirmer I/II, lid and meibomian pathology, meibomian expression, followed by other available tests. New diagnostic tests employ the Oculus Keratograph, which performs non-invasive tear-film analysis and a bulbar redness (BR). The TearLab Osmolarity Test enables rapid clinical evaluation of tear osmolarity. Lipiview is a recently developed diagnostic tool that uses interferometry to quantitatively evaluate tear-film thickness. In DED, epithelial and inflammatory cells produce a variety of inflammatory mediators. A stagnant tear film and decreased concentration of mucin result in the accumulation of inflammatory factors that can penetrate tight junctions and cause epithelial cell death. DED treatment algorithms are based on severity of clinical signs and symptoms, and disease etiology. Therapeutic approaches include lubricating artificial tears and immunomodulatory agents.

  13. Relationship between histopathological changes in post partum renal biopsies and renal function tests of African women with early onset pre-eclampsia.

    PubMed

    Khedun, S M; Naicker, T; Moodley, J

    2000-05-01

    To improve the diagnostic accuracy of concurrent renal disease in hypertension of pregnancy, biopsy evaluation is essential. In addition, establishing underlying renal disease is important for prognosis on future pregnancies. We therefore designed a study to determine the diagnostic yield of postpartum renal biopsy and the nature and frequency of complications associated with this procedure. Also, to determine relationships, if any, between renal function tests and ultrastructural and histopathological findings. Fifty renal biopsies were performed in the immediate postpartum period in black African women with early onset pre-eclampsia. Each biopsy specimen was placed in a separate container and coded so that sampling was unknown to the electron microscopist. Each biopsy specimen was divided into three parts, and processed and stained for light, fluorescent and transmission electron microscopy using conventional techniques. Renal tissue biopsies were adequate for diagnostic purposes in all cases. There were no complications in any of the 50 patients studied. Ultrastructural examination confirmed the light microscopy findings. In addition the ultrastructural findings showed intramembranous deposits, foot process fusion and mesangial deposits. In 16 patients with normal renal function tests; the biopsies evaluation from these patients showed ultrastructural changes. In the remaining 34 patients with abnormal renal function tests of varying severity; biopsy evaluation from these patients showed both ultrastructural and histopathological changes. Renal biopsy procedure is safe, and ultrastructural and histological findings obtained from postpartum renal biopsies are more informative than the routine renal function tests.

  14. Diagnostic methods for atmospheric inversions of long-lived greenhouse gases

    NASA Astrophysics Data System (ADS)

    Michalak, Anna M.; Randazzo, Nina A.; Chevallier, Frédéric

    2017-06-01

    The ability to predict the trajectory of climate change requires a clear understanding of the emissions and uptake (i.e., surface fluxes) of long-lived greenhouse gases (GHGs). Furthermore, the development of climate policies is driving a need to constrain the budgets of anthropogenic GHG emissions. Inverse problems that couple atmospheric observations of GHG concentrations with an atmospheric chemistry and transport model have increasingly been used to gain insights into surface fluxes. Given the inherent technical challenges associated with their solution, it is imperative that objective approaches exist for the evaluation of such inverse problems. Because direct observation of fluxes at compatible spatiotemporal scales is rarely possible, diagnostics tools must rely on indirect measures. Here we review diagnostics that have been implemented in recent studies and discuss their use in informing adjustments to model setup. We group the diagnostics along a continuum starting with those that are most closely related to the scientific question being targeted, and ending with those most closely tied to the statistical and computational setup of the inversion. We thus begin with diagnostics based on assessments against independent information (e.g., unused atmospheric observations, large-scale scientific constraints), followed by statistical diagnostics of inversion results, diagnostics based on sensitivity tests, and analyses of robustness (e.g., tests focusing on the chemistry and transport model, the atmospheric observations, or the statistical and computational framework), and close with the use of synthetic data experiments (i.e., observing system simulation experiments, OSSEs). We find that existing diagnostics provide a crucial toolbox for evaluating and improving flux estimates but, not surprisingly, cannot overcome the fundamental challenges associated with limited atmospheric observations or the lack of direct flux measurements at compatible scales. As atmospheric inversions are increasingly expected to contribute to national reporting of GHG emissions, the need for developing and implementing robust and transparent evaluation approaches will only grow.

  15. Diagnostic Accuracy of Abdominal Ultrasound for Diagnosis of Acute Appendicitis: Systematic Review and Meta-analysis.

    PubMed

    Giljaca, Vanja; Nadarevic, Tin; Poropat, Goran; Nadarevic, Vesna Stefanac; Stimac, Davor

    2017-03-01

    To determine the diagnostic accuracy of abdominal ultrasound (US) for the diagnosis of acute appendicitis (AA), in terms of sensitivity, specificity and post-test probabilities for positive and negative result. A systematic search of MEDLINE, Embase, The Cochrane library and Science Citation Index Expanded from January 1994 to October 2014 was performed. Two authors independently evaluated studies for inclusion, extracted data and performed analyses. The reference standard for evaluation of final diagnosis was pathohistological report on tissue obtained at appendectomy. Summary sensitivity, specificity and post-test probability of AA after positive and negative result of US with corresponding 95% confidence intervals (CI) were calculated. Out of 3306 references identified through electronic searches, 17 reports met the inclusion criteria, with 2841 included participants. The summary sensitivity and specificity of US for diagnosis of AA were 69% (95% CI 59-78%) and 81% (95% CI 73-88%), respectively. At the median pretest probability of AA of 76.4%, the post-test probability for a positive and negative result of US was 92% (95% CI 88-95%) and 55% (95% CI 46-63%), respectively. Abdominal ultrasound does not seem to have a role in the diagnostic pathway for diagnosis of AA in suspected patients. The summary sensitivity and specificity of US do not exceed that of physical examination. Patients that require additional diagnostic workup should be referred to more sensitive and specific diagnostic procedures, such as computed tomography.

  16. Structured syncope care pathways based on lean six sigma methodology optimises resource use with shorter time to diagnosis and increased diagnostic yield.

    PubMed

    Martens, Leon; Goode, Grahame; Wold, Johan F H; Beck, Lionel; Martin, Georgina; Perings, Christian; Stolt, Pelle; Baggerman, Lucas

    2014-01-01

    To conduct a pilot study on the potential to optimise care pathways in syncope/Transient Loss of Consciousness management by using Lean Six Sigma methodology while maintaining compliance with ESC and/or NICE guidelines. Five hospitals in four European countries took part. The Lean Six Sigma methodology consisted of 3 phases: 1) Assessment phase, in which baseline performance was mapped in each centre, processes were evaluated and a new operational model was developed with an improvement plan that included best practices and change management; 2) Improvement phase, in which optimisation pathways and standardised best practice tools and forms were developed and implemented. Staff were trained on new processes and change-management support provided; 3) Sustaining phase, which included support, refinement of tools and metrics. The impact of the implementation of new pathways was evaluated on number of tests performed, diagnostic yield, time to diagnosis and compliance with guidelines. One hospital with focus on geriatric populations was analysed separately from the other four. With the new pathways, there was a 59% reduction in the average time to diagnosis (p = 0.048) and a 75% increase in diagnostic yield (p = 0.007). There was a marked reduction in repetitions of diagnostic tests and improved prioritisation of indicated tests. Applying a structured Lean Six Sigma based methodology to pathways for syncope management has the potential to improve time to diagnosis and diagnostic yield.

  17. Structured Syncope Care Pathways Based on Lean Six Sigma Methodology Optimises Resource Use with Shorter Time to Diagnosis and Increased Diagnostic Yield

    PubMed Central

    Martens, Leon; Goode, Grahame; Wold, Johan F. H.; Beck, Lionel; Martin, Georgina; Perings, Christian; Stolt, Pelle; Baggerman, Lucas

    2014-01-01

    Aims To conduct a pilot study on the potential to optimise care pathways in syncope/Transient Loss of Consciousness management by using Lean Six Sigma methodology while maintaining compliance with ESC and/or NICE guidelines. Methods Five hospitals in four European countries took part. The Lean Six Sigma methodology consisted of 3 phases: 1) Assessment phase, in which baseline performance was mapped in each centre, processes were evaluated and a new operational model was developed with an improvement plan that included best practices and change management; 2) Improvement phase, in which optimisation pathways and standardised best practice tools and forms were developed and implemented. Staff were trained on new processes and change-management support provided; 3) Sustaining phase, which included support, refinement of tools and metrics. The impact of the implementation of new pathways was evaluated on number of tests performed, diagnostic yield, time to diagnosis and compliance with guidelines. One hospital with focus on geriatric populations was analysed separately from the other four. Results With the new pathways, there was a 59% reduction in the average time to diagnosis (p = 0.048) and a 75% increase in diagnostic yield (p = 0.007). There was a marked reduction in repetitions of diagnostic tests and improved prioritisation of indicated tests. Conclusions Applying a structured Lean Six Sigma based methodology to pathways for syncope management has the potential to improve time to diagnosis and diagnostic yield. PMID:24927475

  18. Diagnostic potential of nested PCR, galactomannan EIA, and beta-D-glucan for invasive aspergillosis in pediatric patients.

    PubMed

    Badiee, Parisa; Alborzi, Abdolvahab; Karimi, Mahammad; Pourabbas, Bahman; Haddadi, Pedram; Mardaneh, Jalal; Moieni, Mahsa

    2012-04-13

    Limited specific data and investigations are available for invasive aspergillosis (IA) in pediatric patients. We evaluated the diagnostic potential of three noninvasive tests including the Platelia Aspergillus EIA kit for using galactomannan antigen, (1,3)-β-D-glucan Detection Reagent Kit, and nested-PCR for Aspergillus DNA in sera. We evaluated the diagnostic potential of three noninvasive tests including EIA for galactomannan antigen  (Platelia Aspergillus), nested  PCR assay for Aspergillus DNA and test for (1→3)-β-D-glucan (Glucatell assay Kit). All pediatric patients treated at the hematology/oncology unit who were at increased risk of developing invasive aspergillosis were enrolled. Clinical samples were examined for Aspergillus infections by mycological methods. Serial blood samples were collected twice weekly and evaluated by noninvasive tests. We analyzed 230 consecutive blood samples from 62 pediatric patients. The incidence rate of invasive aspergillosis in the patients was found to be 27.4%, and the etiologic agents were Aspergillus flavus, Aspergillus fumigatus, and Aspergillus spp.  The sensitivity, specificity, positive and negative predictive values, and likelihood ratios for positive and negative results of galactomannan in patients with proven and probable IA were 90%, 92%, 81.8%, 96%, 11.25, and 0.1; for beta-D-glucan they were 50%, 46%, 26%, 70.6%, 0.9, 0.9; and for nested-PCR they were 80%, 96.2%, 88.9%, 92.6%, 21, and 0.2, respectively. The conventional methods are not able to detect IA, due to the lack of valid and proper sampling. Galactomannan and nested-PCR tests in serum, with enough accuracy and reliability, can serve as noninvasive methods for the detection of IA in pediatric patients. However, the beta-D-glucan test cannot serve as an efficient diagnostic tool in those with hematologic disorders. 

  19. Investigation of Tapered Roller Bearing Damage Detection Using Oil Debris Analysis

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Krieder, Gary; Fichter, Thomas

    2006-01-01

    A diagnostic tool was developed for detecting fatigue damage to tapered roller bearings. Tapered roller bearings are used in helicopter transmissions and have potential for use in high bypass advanced gas turbine aircraft engines. This diagnostic tool was developed and evaluated experimentally by collecting oil debris data from failure progression tests performed by The Timken Company in their Tapered Roller Bearing Health Monitoring Test Rig. Failure progression tests were performed under simulated engine load conditions. Tests were performed on one healthy bearing and three predamaged bearings. During each test, data from an on-line, in-line, inductance type oil debris sensor was monitored and recorded for the occurrence of debris generated during failure of the bearing. The bearing was removed periodically for inspection throughout the failure progression tests. Results indicate the accumulated oil debris mass is a good predictor of damage on tapered roller bearings. The use of a fuzzy logic model to enable an easily interpreted diagnostic metric was proposed and demonstrated.

  20. Evaluation of the Cobas TaqMan MTB Test for the Detection of Mycobacterium tuberculosis Complex According to Acid-Fast-Bacillus Smear Grades in Respiratory Specimens

    PubMed Central

    Huh, Hee Jae; Koh, Won-Jung; Song, Dong Joon

    2014-01-01

    We evaluated the performance of the Cobas TaqMan MTB test (Roche Diagnostics, Basel, Switzerland), stratified by acid-fast bacilli (AFB) smear grades. The sensitivity of this test in smear-positive specimens was >95% in all grades, while that in trace and negative specimens was 85.3% and 34.4%, respectively. PMID:25428157

  1. Diagnostic reliability of 3.0-T MRI for detecting osseous abnormalities of the temporomandibular joint.

    PubMed

    Sawada, Kunihiko; Amemiya, Toshihiko; Hirai, Shigenori; Hayashi, Yusuke; Suzuki, Toshihiro; Honda, Masahiko; Sisounthone, Johnny; Matsumoto, Kunihito; Honda, Kazuya

    2018-01-01

    We compared the diagnostic reliability of 3.0-T magnetic resonance imaging (MRI) for detection of osseous abnormalities of the temporomandibular joint (TMJ) with that of the gold standard, cone-beam computed tomography (CBCT). Fifty-six TMJs were imaged with CBCT and MRI, and images of condyles and fossae were independently assessed for the presence of osseous abnormalities. The accuracy, sensitivity, and specificity of 3.0-T MRI were 0.88, 1.0, and 0.73, respectively, in condyle evaluation and 0.91, 0.75, and 0.95 in fossa evaluation. The McNemar test showed no significant difference (P > 0.05) between MRI and CBCT in the evaluation of osseous abnormalities in condyles and fossae. The present results indicate that 3.0-T MRI is equal to CBCT in the diagnostic evaluation of osseous abnormalities of the mandibular condyle.

  2. Diagnostic value of ST-segment deviations during cardiac exercise stress testing: Systematic comparison of different ECG leads and time-points.

    PubMed

    Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias

    2017-07-01

    Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, p<0.001). When using ECG stress testing for evaluation of patients with suspected myocardial ischemia, the diagnostic accuracy of ST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Field evaluation of a recombinase polymerase amplification assay for the diagnosis of Schistosoma japonicum infection in Hunan province of China.

    PubMed

    Xing, Weiwei; Yu, Xinling; Feng, Jingtao; Sun, Kui; Fu, Wenliang; Wang, Yuanyuan; Zou, Minji; Xia, Wenrong; Luo, Zhihong; He, Hongbin; Li, Yuesheng; Xu, Donggang

    2017-02-21

    Current diagnostic methods for Schistosoma japonicum infection are insensitive for low-density infections. Therefore, a new diagnostic assay based on recombinase polymerase amplification (RPA) technology was established and assessed for field applification. The S.japonicum RPA assay was developed to target highly repetitive retrotransposon SjR2 gene of S japonicum, and its sensitivity and specificity were assessed by serial dilution of S. japonicum genomic DNA and other related worm genomic DNA respectively. The RPA diagnostic validity was first evaluated in 60 fecal samples from healthy people and patients, and then compared with other diagnostic tests in 200 high-risk individuals living in endemic areas. The real time RPA assay could detect 0.9 fg S. japonicum DNA within 15 min and distinguish S. japonicum from other worms. The validity analysis of RPA for the detection of S. japonicum in stool samples from 30 S. japonicum-infected patients and 30 healthy persons indicated 100% sensitivity and specificity. When testing 200 fecal or serum samples from a high-risk population, the percentage sensitivity of RPA was 100%, whereas that of indirect hemagglutination assay (IHA) and enzyme-linked immunosorbent assay (ELISA) were 80.3% and 85.2% respectively. In addition, the RPA presented better consistency with the stool-based tests than IHA and ELISA. Overall, the RPA was superior to other detection methods with respect to detection time, sensitivity, and convenience. This is the first time we applied the RPA technology to the field evaluation of S. japonicum infection. And the results suggest that RPA-based assays can be used as a promising point-of-care test for the diagnosis of schistosomiasis.

  4. The Diagnostic Performance of Stool DNA Testing for Colorectal Cancer: A Systematic Review and Meta-Analysis.

    PubMed

    Zhai, Rong-Lin; Xu, Fei; Zhang, Pei; Zhang, Wan-Li; Wang, Hui; Wang, Ji-Liang; Cai, Kai-Lin; Long, Yue-Ping; Lu, Xiao-Ming; Tao, Kai-Xiong; Wang, Guo-Bin

    2016-02-01

    This meta-analysis was designed to evaluate the diagnostic performance of stool DNA testing for colorectal cancer (CRC) and compare the performance between single-gene and multiple-gene tests.MEDLINE, Cochrane, EMBASE databases were searched using keywords colorectal cancers, stool/fecal, sensitivity, specificity, DNA, and screening. Sensitivity analysis, quality assessments, and performance bias were performed for the included studies.Fifty-three studies were included in the analysis with a total sample size of 7524 patients. The studies were heterogeneous with regard to the genes being analyzed for fecal genetic biomarkers of CRC, as well as the laboratory methods being used for each assay. The sensitivity of the different assays ranged from 2% to 100% and the specificity ranged from 81% to 100%. The meta-analysis found that the pooled sensitivities for single- and multigene assays were 48.0% and 77.8%, respectively, while the pooled specificities were 97.0% and 92.7%. Receiver operator curves and diagnostic odds ratios showed no significant difference between both tests with regard to sensitivity or specificity.This meta-analysis revealed that using assays that evaluated multiple genes compared with single-gene assays did not increase the sensitivity or specificity of stool DNA testing in detecting CRC.

  5. Provision of personalized genomic diagnostic technologies for breast and colorectal cancer: an analysis of patient needs, expectations and priorities.

    PubMed

    Issa, Amalia M; Hutchinson, Janis F; Tufail, Waqas; Fletcher, Erica; Ajike, Roseline; Tenorio, Jose

    2011-07-01

    Several novel pharmacogenomic diagnostic tests are commercially available for breast and colorectal cancer, and are increasingly being used in clinical practice for improving treatment decisions. However, there is little evidence evaluating the value of these new genomic technologies from the perspective of patients. As part of an ongoing effort to understand the continuum of the process of adoption of genomic diagnostics, our aim in this study was to examine the value of genomic diagnostics to breast and colorectal cancer patients, and their willingness to adopt and use genomic diagnostics. We conducted six focus groups of breast and colorectal cancer patients from the oncology clinics at The Methodist Hospital, Houston, TX, USA. An adapted Q-sort instrument was also administered to focus group participants. The majority of breast and colorectal cancer patients are interested in using novel genomic diagnostics for deciding about treatment options. Most participants in our study expressed a willingness to pay out-of-pocket for genomic testing (z = 0.736). Reliability and validity of genomic testing were of significant concern (z = 1.32) for the majority of breast and colorectal cancer patients. Participants identified several facilitators and barriers within health systems that might either facilitate or impede the widespread adoption and use of genomic diagnostics in healthcare delivery. This study demonstrates breast and colorectal cancer patients' willingness to adopt and pay for novel genomic diagnostics, as well as identifies several salient factors associated with patient preferences for genomic diagnostics.

  6. Evaluation of the painful athletic hip: imaging options and imaging-guided injections.

    PubMed

    Jacobson, Jon A; Bedi, Asheesh; Sekiya, Jon K; Blankenbaker, Donna G

    2012-09-01

    This article reviews diagnostic imaging tests and injections that provide important information for clinical management of patients with sports-related hip pain. In the evaluation of sports-related hip symptoms, MR arthrography is often used to evaluate intraarticular pathology of the hip. The addition of short- and long-acting anesthetic agents with the MR arthrography injection adds additional information that can distinguish between symptomatic and asymptomatic imaging findings. Osseous abnormalities can be characterized with radiography, MRI, or CT. Ultrasound is important in the assessment of iliopsoas abnormalities, including tendon snapping, and to guide diagnostic anesthetic injection.

  7. Molecular diagnostics for hereditary hearing loss in children.

    PubMed

    Sommen, Manou; Wuyts, Wim; Van Camp, Guy

    2017-08-01

    Hearing loss (HL) is the most common birth defect in industrialized countries with far-reaching social, psychological and cognitive implications. It is an extremely heterogeneous disease, complicating molecular testing. The introduction of next-generation sequencing (NGS) has resulted in great progress in diagnostics allowing to study all known HL genes in a single assay. The diagnostic yield is currently still limited, but has the potential to increase substantially. Areas covered: In this review the utility of NGS and the problems for comprehensive molecular testing for HL are evaluated and discussed. Expert commentary: Different publications have proven the appropriateness of NGS for molecular testing of heterogeneous diseases such as HL. However, several problems still exist, such as pseudogenic background of some genes and problematic copy number variant analysis on targeted NGS data. Another main challenge for the future will be the establishment of population specific mutation-spectra to achieve accurate personalized comprehensive molecular testing for HL.

  8. ALK evaluation in the world of multiplex testing: Network Genomic Medicine (NGM): the Cologne model for implementing personalised oncology.

    PubMed

    Heydt, C; Kostenko, A; Merkelbach-Bruse, S; Wolf, J; Büttner, R

    2016-09-01

    Comprehensive molecular genotyping of lung cancers has become a key requirement for guiding therapeutic decisions. As a paradigm model of implementing next-generation comprehensive diagnostics, Network Genomic Medicine (NGM) has established central diagnostic and clinical trial platforms for centralised testing and decentralised personalised treatment in clinical practice. Here, we describe the structures of the NGM network and give a summary of technologies to identify patients with anaplastic lymphoma kinase (ALK) fusion-positive lung adenocarcinomas. As unifying test platforms will become increasingly important for delivering reliable, quick and affordable tests, the NGM diagnostic platform is currently implementing a comprehensive hybrid capture-based parallel sequencing pan-cancer assay. © The Author 2016. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  9. Advanced Techniques in Pulmonary Function Test Analysis Interpretation and Diagnosis

    PubMed Central

    Gildea, T.J.; Bell, C. William

    1980-01-01

    The Pulmonary Functions Analysis and Diagnostic System is an advanced clinical processing system developed for use at the Pulmonary Division, Department of Medicine at the University of Nebraska Medical Center. The system generates comparative results and diagnostic impressions for a variety of routine and specialized pulmonary functions test data. Routine evaluation deals with static lung volumes, breathing mechanics, diffusing capacity, and blood gases while specialized tests include lung compliance studies, small airways dysfunction studies and dead space to tidal volume ratios. Output includes tabular results of normal vs. observed values, clinical impressions and commentary and, where indicated, a diagnostic impression. A number of pulmonary physiological and state variables are entered or sampled (A to D) with periodic status reports generated for the test supervisor. Among the various physiological variables sampled are respiratory frequency, minute ventilation, oxygen consumption, carbon dioxide production, and arterial oxygen saturation.

  10. Clinical Diagnostic Utility of IP-10 and LAM Antigen Levels for the Diagnosis of Tuberculous Pleural Effusions in a High Burden Setting

    PubMed Central

    Dheda, Keertan; Van-Zyl Smit, Richard N.; Sechi, Leonardo A.; Badri, Motasim; Meldau, Richard; Symons, Gregory; Khalfey, Hoosein; Carr, Igshaan; Maredza, Alice; Dawson, Rodney; Wainright, Helen; Whitelaw, Andrew; Bateman, Eric D.; Zumla, Alimuddin

    2009-01-01

    Background Current tools for the diagnosis of tuberculosis pleural effusions are sub-optimal. Data about the value of new diagnostic technologies are limited, particularly, in high burden settings. Preliminary case control studies have identified IFN-γ-inducible-10kDa protein (IP-10) as a promising diagnostic marker; however, its diagnostic utility in a day-to-day clinical setting is unclear. Detection of LAM antigen has not previously been evaluated in pleural fluid. Methods We investigated the comparative diagnostic utility of established (adenosine deaminase [ADA]), more recent (standardized nucleic-acid-amplification-test [NAAT]) and newer technologies (a standardized LAM mycobacterial antigen-detection assay and IP-10 levels) for the evaluation of pleural effusions in 78 consecutively recruited South African tuberculosis suspects. All consenting participants underwent pleural biopsy unless contra-indicated or refused. The reference standard comprised culture positivity for M. tuberculosis or histology suggestive of tuberculosis. Principal Findings Of 74 evaluable subjects 48, 7 and 19 had definite, probable and non-TB, respectively. IP-10 levels were significantly higher in TB vs non-TB participants (p<0.0001). The respective outcomes [sensitivity, specificity, PPV, NPV %] for the different diagnostic modalities were: ADA at the 30 IU/L cut-point [96; 69; 90; 85], NAAT [6; 93; 67; 28], IP-10 at the 28,170 pg/ml ROC-derived cut-point [80; 82; 91; 64], and IP-10 at the 4035 pg/ml cut-point [100; 53; 83; 100]. Thus IP-10, using the ROC-derived cut-point, missed ∼20% of TB cases and mis-diagnosed ∼20% of non-TB cases. By contrast, when a lower cut-point was used a negative test excluded TB. The NAAT had a poor sensitivity but high specificity. LAM antigen-detection was not diagnostically useful. Conclusion Although IP-10, like ADA, has sub-optimal specificity, it may be a clinically useful rule-out test for tuberculous pleural effusions. Larger multi-centric studies are now required to confirm our findings. PMID:19277111

  11. Saliva as a non-invasive diagnostic tool for inflammation and insulin-resistance

    PubMed Central

    Desai, Gauri S; Mathews, Suresh T

    2014-01-01

    Saliva has been progressively studied as a non-invasive and relatively stress-free diagnostic alternative to blood. Currently, saliva testing is used for clinical assessment of hormonal perturbations, detection of HIV antibodies, DNA analysis, alcohol screening, and drug testing. Recently, there has been increasing interest in evaluating the diagnostic potential of saliva in obesity, inflammation, and insulin-resistance. Current literature has demonstrated elevated levels of inflammatory biomarkers including C-reactive protein, tumor necrosis factor-α, interleukin-6, and interferon-γ in saliva of obese/overweight children and adults. Salivary antioxidant status has also been studied as a measure of oxidative stress in individuals with type 2 diabetes. Further, several studies have demonstrated correlations of salivary markers of stress and insulin resistance including cortisol, insulin, adiponectin, and resistin with serum concentrations. These findings suggest the potential diagnostic value of saliva in health screening and risk stratification studies, particularly in the pediatric population, with implications for inflammatory, metabolic and cardiovascular conditions. However, additional studies are required to standardize saliva collection and storage procedures, validate analytical techniques for biomarker detection, and establish reference ranges for routine clinical use. The purpose of this review is to summarize and evaluate recent advancements in using saliva as a diagnostic tool for inflammation and insulin-resistance. PMID:25512775

  12. Bile acid malabsorption in patients with chronic diarrhoea: clinical value of SeHCAT test.

    PubMed

    Wildt, S; Nørby Rasmussen, S; Lysgård Madsen, J; Rumessen, J J

    2003-08-01

    Bile acid malabsorption (BAM), a cause of chronic diarrhoea, can be diagnosed by the SeHCAT test. The purpose of this study was to evaluate the usefulness of SeHCAT testing by assessing the extent of BAM and describing the clinical characteristics in a group of patients with chronic diarrhoea. Clinical outcome after treatment with cholestyramine was also evaluated. During a 5-year period (1997-2001) the SeHCAT test was performed in 135 patients in whom a primary programme for diagnostic evaluation of chronic diarrhoea had not revealed a cause. File data from 133 patients could be evaluated. In 44% of patients, bile acid absorption was normal with SeHCAT retention > or = 15%. Impaired SeHCAT retention was found in 56%. All patients with ileocaecal resections had retention values < 10%. Patients with microscopic colitis presented with BAM in 39%. Only one patient with idiopathic BAM presented with steatorrhoea as opposed to 11 patients with type 1 and 3 BAM. Patients with idiopathic BAM and/or SeHCAT retention values < 5% had the best response to treatment with cholestyramine. The SeHCAT test is of value in evaluation of patients with chronic diarrhoea as a second-line investigation with a high diagnostic yield. The only a priori parameter to predict BAM was the existence of ileocaecal resections. The result of the SeHCAT test seems to predict the benefit of treatment with cholestyramine.

  13. The development of a quality appraisal tool for studies of diagnostic reliability (QAREL).

    PubMed

    Lucas, Nicholas P; Macaskill, Petra; Irwig, Les; Bogduk, Nikolai

    2010-08-01

    In systematic reviews of the reliability of diagnostic tests, no quality assessment tool has been used consistently. The aim of this study was to develop a specific quality appraisal tool for studies of diagnostic reliability. Key principles for the quality of studies of diagnostic reliability were identified with reference to epidemiologic principles, existing quality appraisal checklists, and the Standards for Reporting of Diagnostic Accuracy (STARD) and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) resources. Specific items that encompassed each of the principles were developed. Experts in diagnostic research provided feedback on the items that were to form the appraisal tool. This process was iterative and continued until consensus among experts was reached. The Quality Appraisal of Reliability Studies (QAREL) checklist includes 11 items that explore seven principles. Items cover the spectrum of subjects, spectrum of examiners, examiner blinding, order effects of examination, suitability of the time interval among repeated measurements, appropriate test application and interpretation, and appropriate statistical analysis. QAREL has been developed as a specific quality appraisal tool for studies of diagnostic reliability. The reliability of this tool in different contexts needs to be evaluated. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  14. A systematic review of the PTSD Checklist's diagnostic accuracy studies using QUADAS.

    PubMed

    McDonald, Scott D; Brown, Whitney L; Benesek, John P; Calhoun, Patrick S

    2015-09-01

    Despite the popularity of the PTSD Checklist (PCL) as a clinical screening test, there has been no comprehensive quality review of studies evaluating its diagnostic accuracy. A systematic quality assessment of 22 diagnostic accuracy studies of the English-language PCL using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) assessment tool was conducted to examine (a) the quality of diagnostic accuracy studies of the PCL, and (b) whether quality has improved since the 2003 STAndards for the Reporting of Diagnostic accuracy studies (STARD) initiative regarding reporting guidelines for diagnostic accuracy studies. Three raters independently applied the QUADAS tool to each study, and a consensus among the 4 authors is reported. Findings indicated that although studies generally met standards in several quality areas, there is still room for improvement. Areas for improvement include establishing representativeness, adequately describing clinical and demographic characteristics of the sample, and presenting better descriptions of important aspects of test and reference standard execution. Only 2 studies met each of the 14 quality criteria. In addition, study quality has not appreciably improved since the publication of the STARD Statement in 2003. Recommendations for the improvement of diagnostic accuracy studies of the PCL are discussed. (c) 2015 APA, all rights reserved).

  15. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study

    PubMed Central

    Shimelis, Techalew; Tadesse, Endale

    2015-01-01

    Objective To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. Design A hospital-based cross-sectional study. Setting This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Participants Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. Outcome measures HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). Results The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. Conclusions The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. PMID:25908677

  16. The diagnostic performance evaluation of the SD BIOLINE HIV/syphilis Duo rapid test in southern Ethiopia: a cross-sectional study.

    PubMed

    Shimelis, Techalew; Tadesse, Endale

    2015-04-23

    To determine the diagnostic performance of the SD BIOLINE HIV/syphilis Duo rapid test. A hospital-based cross-sectional study. This evaluation was conducted at one of the largest hospitals in southern Ethiopia. Serum samples obtained from clients attending the antiretroviral therapy and voluntary counselling and testing centres were used. Sera were originally collected for the purpose of investigating syphilis epidemiology. The performance of the test to detect HIV was evaluated using 400 sera (200 HIV positives and 200 HIV negatives). Also, its performance to detect syphilis was evaluated using 85 syphilis positive and 100 syphilis negative serum samples. Individuals <15 years of age or syphilis treated or those with ≤50 cells/µL CD4 cell count were originally excluded. HIV screening was carried out according to the national rapid diagnostic testing (RDT) algorithm: Shenghai Kehua Bioengineering (KHB) test kit as a screening test, followed by the HIV1/2 STAT-PAK assay if positive. Where the result of the STAT-PAK is discordant with KHB, Unigold HIV is used as a tiebreaker to determine the result. We also used ELISA to resolve discordant HIV results. Syphilis serostatus was determined using the Treponema pallidum haemagglutination assay (TPHA). The respective sensitivity, specificity, positive predictive value and negative predictive value of the SD BIOLINE HIV/syphilis Duo test were 100, 99.5, 99.5 and 100% for HIV and 97.6, 96, 95.4 and 98% for syphilis testing, respectively. In reference to TPHA, the test kit reported 4 false positives and 2 false negative results for syphilis. The κ values were 0.99 for HIV testing and 0.94 for syphilis testing. The excellent performance of the SD BIOLINE HIV/syphilis Duo test to detect HIV as well as syphilis facilitates the integration of syphilis testing and treatment to the already established HIV prevention programme, ultimately contributing to the dual HIV and syphilis elimination goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Predictive Validity of Self-Report Questionnaires in the Assessment of Autism Spectrum Disorders in Adults

    ERIC Educational Resources Information Center

    Sizoo, Bram B.; Horwitz, E. H.; Teunisse, J. P.; Kan, C. C.; Vissers, C. T. W. M.; Forceville, E. J. M.; Van Voorst, A. J. P.; Geurts, H. M.

    2015-01-01

    While various screening instruments for autism spectrum disorders are widely used in diagnostic assessments, their psychometric properties have not been simultaneously evaluated in the outpatient setting where these instruments are used most. In this study, we tested the Ritvo Autism Asperger Diagnostic Scale-Revised and two short versions of the…

  18. Acquiring, Representing, and Evaluating a Competence Model of Diagnostic Strategy.

    ERIC Educational Resources Information Center

    Clancey, William J.

    This paper describes NEOMYCIN, a computer program that models one physician's diagnostic reasoning within a limited area of medicine. NEOMYCIN's knowledge base and reasoning procedure constitute a model of how human knowledge is organized and how it is used in diagnosis. The hypothesis is tested that such a procedure can be used to simulate both…

  19. Accuracy of Immunofluorescence in the Diagnosis of Primary Ciliary Dyskinesia

    PubMed Central

    Frost, Emily; Dixon, Mellisa; Ollosson, Sarah; Kilpin, Kate; Patel, Mitali; Scully, Juliet; Rogers, Andrew V.; Mitchison, Hannah M.; Bush, Andrew; Hogg, Claire

    2017-01-01

    Rationale: The standard approach to diagnosis of primary ciliary dyskinesia (PCD) in the United Kingdom consists of assessing ciliary function by high-speed microscopy and ultrastructure by election microscopy, but equipment and expertise is not widely available internationally. The identification of biallelic disease-causing mutations is also diagnostic, but many disease-causing genes are unknown, and testing is not widely available outside the United States. Fluorescent antibodies to ciliary proteins are used to validate research genetic studies, but diagnostic utility in this disease has not been systematically evaluated. Objectives: To determine utility of a panel of six fluorescent labeled antibodies as a diagnostic tool for PCD. Methods: The study used immunofluorescent labeling of nasal brushings from a discovery cohort of 35 patients diagnosed with PCD by ciliary ultrastructure, and a diagnostic accuracy cohort of 386 patients referred with symptoms suggestive of disease. The results were compared with diagnostic outcome. Measurements and Main Results: Immunofluorescence correctly identified mislocalized or absent staining in 100% of the discovery cohort. In the diagnostic cohort immunofluorescence successfully identified 22 of 25 patients with PCD and normal staining in all 252 in whom PCD was considered highly unlikely. In addition, immunofluorescence provided a result in 55% (39) of cases that were previously inconclusive. Immunofluorescence results were available within 14 days, costing $187 per sample compared with electron microscopy (27 days; cost $1,452). Conclusions: Immunofluorescence is a highly specific diagnostic test for PCD, and it improves the speed and availability of diagnostic testing. However, sensitivity is limited and immunofluorescence is not suitable as a stand-alone test. PMID:28199173

  20. Development of a molecular diagnostic test for Retinitis Pigmentosa in the Japanese population.

    PubMed

    Maeda, Akiko; Yoshida, Akiko; Kawai, Kanako; Arai, Yuki; Akiba, Ryutaro; Inaba, Akira; Takagi, Seiji; Fujiki, Ryoji; Hirami, Yasuhiko; Kurimoto, Yasuo; Ohara, Osamu; Takahashi, Masayo

    2018-05-21

    Retinitis Pigmentosa (RP) is the most common form of inherited retinal dystrophy caused by different genetic variants. More than 60 causative genes have been identified to date. The establishment of cost-effective molecular diagnostic tests with high sensitivity and specificity can be beneficial for patients and clinicians. Here, we developed a clinical diagnostic test for RP in the Japanese population. Evaluation of diagnostic technology, Prospective, Clinical and experimental study. A panel of 39 genes reported to cause RP in Japanese patients was established. Next generation sequence (NGS) technology was applied for the analyses of 94 probands with RP and RP-related diseases. After interpretation of detected genetic variants, molecular diagnosis based on a study of the genetic variants and a clinical phenotype was made by a multidisciplinary team including clinicians, researchers and genetic counselors. NGS analyses found 14,343 variants from 94 probands. Among them, 189 variants in 83 probands (88.3% of all cases) were selected as pathogenic variants and 64 probands (68.1%) have variants which can cause diseases. After the deliberation of these 64 cases, molecular diagnosis was made in 43 probands (45.7%). The final molecular diagnostic rate with the current system combining supplemental Sanger sequencing was 47.9% (45 of 94 cases). The RP panel provides the significant advantage of detecting genetic variants with a high molecular diagnostic rate. This type of race-specific high-throughput genotyping allows us to conduct a cost-effective and clinically useful genetic diagnostic test.

  1. A systematic review of the clinical, public health and cost-effectiveness of rapid diagnostic tests for the detection and identification of bacterial intestinal pathogens in faeces and food.

    PubMed

    Abubakar, I; Irvine, L; Aldus, C F; Wyatt, G M; Fordham, R; Schelenz, S; Shepstone, L; Howe, A; Peck, M; Hunter, P R

    2007-09-01

    To determine the diagnostic accuracy of tests for the rapid diagnosis of bacterial food poisoning in clinical and public health practice and to estimate the cost-effectiveness of these assays in a hypothetical population in order to inform policy on the use of these tests. Studies evaluating diagnostic accuracy of rapid tests were retrieved using electronic databases and handsearching reference lists and key journals. Hospital laboratories and test manufacturers were contacted for cost data, and clinicians involved in the care of patients with food poisoning were invited to discuss the conclusions of this review using the nominal group technique. A systematic review of the current medical literature on assays used for the rapid diagnosis of bacterial food poisoning was carried out. Specific organisms under review were Salmonella, Campylobacter, Escherichia coli O157, Staphylococcus aureus, Clostridium perfringens and Bacillus cereus. Data extraction was undertaken using standardised data extraction forms. Where a sufficient number of studies evaluating comparable tests were identified, meta-analysis was performed. A decision analytic model was developed, using effectiveness data from the review and cost data from hospitals and manufacturers, which contributed to an assessment of the cost-effectiveness of rapid tests in a hypothetical UK population. Finally, diagnostic accuracy and cost-effectiveness results were presented to a focus group of GPs, microbiologists and consultants in communicable disease control, to assess professional opinion on the use of rapid tests in the diagnosis of food poisoning. Good test performance levels were observed with rapid test methods, especially for polymerase chain reaction (PCR) assays. The estimated levels of diagnostic accuracy using the area under the curve of the summary receiver operating characteristic curve was very high. Indeed, although traditional culture is the natural reference test to use for comparative statistical analysis, on many occasions the rapid test outperforms culture, detecting additional 'truly' positive cases of food-borne illness. The significance of these additional positives requires further investigation. Economic modelling suggests that adoption of rapid tests in combination with routine culture is unlikely to be cost-effective, however, as the cost of rapid technologies decreases; total replacement with rapid technologies may be feasible. Despite the relatively poor quality of reporting of studies evaluating rapid detection methods, the reviewed evidence shows that PCR for Campylobacter, Salmonella and E. coli O157 is potentially very successful in identifying pathogens, possibly detecting more than the number currently reported using culture. Less is known about the benefits of testing for B. cereus, C. perfringens and S. aureus. Further investigation is needed on how clinical outcomes may be altered if test results are available more quickly and at a greater precision than in the current practice of bacterial culture.

  2. Performance of the High-Energy Single-Event Effects Test Facility (SEETF) at Michigan State University's National Superconducting Cyclotron Laboratory (NSCL)

    NASA Technical Reports Server (NTRS)

    Ladbury, R.; Reed, R. A.; Marshall, P. W.; LaBel, K. A.; Anantaraman, R.; Fox, R.; Sanderson, D. P.; Stolz, A.; Yurkon, J.; Zeller, A. F.; hide

    2004-01-01

    The performance of Michigan State University's Single-Event Effects Test Facility (SEETF) during its inaugural runs is evaluated. Beam profiles and other diagnostics are presented, and prospects for future development and testing are discussed.

  3. Comparative Evaluation of Bivalent Malaria Rapid Diagnostic Tests versus Traditional Methods in Field with Special Reference to Heat Stability Testing in Central India

    PubMed Central

    Singh, Neeru; Bharti, Praveen K.; Singh, Mrigendra P.; Mishra, Sweta; Shukla, Man M.; Sharma, Ravendra K.; Singh, Rajesh K.

    2013-01-01

    Background Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs) showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability. Methodology/Principal Findings This study was undertaken in four forested districts of central India (July, 2011– March, 2012). All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9–98.8) and lowest sensitivity was 76% (95% CI; 71.7–79.6). For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9) and 20% (95% CI; 15.6–24.5) respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6–0.9). Conclusion This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely. PMID:23472135

  4. Evaluation of the Clearview® Malaria pLDH Malaria Rapid Diagnostic Test in a non-endemic setting.

    PubMed

    Houzé, Sandrine; Hubert, Véronique; Cohen, Dorit Pessler; Rivetz, Baruch; Le Bras, Jacques

    2011-09-27

    Malaria Rapid Diagnostic Tests (RDTs) are widely used to diagnose malaria. The present study evaluated a new RDT, the Clearview® Malaria pLDH test targeting the pan-Plasmodium antigen lactate dehydrogenase (pLDH). The Clearview® Malaria pLDH test was evaluated on fresh samples obtained in returned international travellers using microscopy corrected by PCR as the reference method. Included samples were Plasmodium falciparum (139), Plasmodium vivax (22), Plasmodium ovale (20), Plasmodium malariae (7), and 102 negative. Overall sensitivity for the detection of Plasmodium spp was 93.2%. For P. falciparum, the sensitivity was 98.6%; for P. vivax, P. ovale and P. malariae, overall sensitivities were 90.9%, 60.0% and 85.7% respectively. For P. falciparum and for P. vivax, the sensitivities increased to 100% at parasite densities above 100/μl. The specificity was 100%. The test was easily to perform and the result was stable for at least 1 hour. The Clearview® Malaria pLDH was efficient for the diagnosis of malaria. The test was very sensitive for P. falciparum and P. vivax detection. The sensitivities for P. ovale and P. malariae were better than other RDTs.

  5. "Combined Diagnostic Tool" APPlication to a Retrospective Series of Patients Undergoing Total Joint Revision Surgery.

    PubMed

    Gallazzi, Enrico; Drago, Lorenzo; Baldini, Andrea; Stockley, Ian; George, David A; Scarponi, Sara; Romanò, Carlo L

    2017-01-01

    Background : Differentiating between septic and aseptic joint prosthesis may be challenging, since no single test is able to confirm or rule out infection. The choice and interpretation of the panel of tests performed in any case often relies on empirical evaluation and poorly validated scores. The "Combined Diagnostic Tool (CDT)" App, a smartphone application for iOS, was developed to allow to automatically calculate the probability of having a of periprosthetic joint infection, on the basis of the relative sensitivity and specificity of the positive and negative diagnostic tests performed in any given patient. Objective : The aim of the present study was to apply the CDT software to investigate the ability of the tests routinely performed in three high-volume European centers to diagnose a periprosthetic infection. Methods : This three-center retrospective study included 120 consecutive patients undergoing total hip or knee revision, and included 65 infected patients (Group A) and 55 patients without infection (Group B). The following parameters were evaluated: number and type of positive and negative diagnostic tests performed pre-, intra- and post-operatively and resultant probability calculated by the CDT App of having a peri-prosthetic joint infection, based on pre-, intra- and post-operative combined tests. Results : Serological tests were the most common performed, with an average 2.7 tests per patient for Group A and 2.2 for Group B, followed by joint aspiration (0.9 and 0.8 tests per patient, respectively) and imaging techniques (0.5 and 0.2 test per patient). Mean CDT App calculated probability of having an infection based on pre-operative tests was 79.4% for patients in Group A and 35.7 in Group B. Twenty-nine patients in Group A had > 10% chance of not having an infection, and 29 of Group B had > 10% chance of having an infection. Conclusion : This is the first retrospective study focused on investigating the number and type of tests commonly performed prior to joint revision surgery and aimed at evaluating their combined ability to diagnose a peri-prosthetic infection. CDT App allowed us to demonstrate that, on average, the routine combination of commonly used tests is unable to diagnose pre-operatively a peri-prosthetic infection with a probability higher than 90%.

  6. [Diagnostic evaluation of the developmental level in children identified at risk of delay through the Child Development Evaluation Test].

    PubMed

    Rizzoli-Córdoba, Antonio; Campos-Maldonado, Martha Carmen; Vélez-Andrade, Víctor Hugo; Delgado-Ginebra, Ismael; Baqueiro-Hernández, César Iván; Villasís-Keever, Miguel Ángel; Reyes-Morales, Hortensia; Ojeda-Lara, Lucía; Davis-Martínez, Erika Berenice; O'Shea-Cuevas, Gabriel; Aceves-Villagrán, Daniel; Carrasco-Mendoza, Joaquín; Villagrán-Muñoz, Víctor Manuel; Halley-Castillo, Elizabeth; Sidonio-Aguayo, Beatriz; Palma-Tavera, Josuha Alexander; Muñoz-Hernández, Onofre

    The Child Development Evaluation (or CDE Test) was developed in Mexico as a screening tool for child developmental problems. It yields three possible results: normal, slow development or risk of delay. The modified version was elaborated using the information obtained during the validation study but its properties according to the base population are not known. The objective of this work was to establish diagnostic confirmation of developmental delay in children 16- to 59-months of age previously identified as having risk of delay through the CDE Test in primary care facilities. A population-based cross-sectional study was conducted in one Mexican state. CDE test was administered to 11,455 children 16- to 59-months of age from December/2013 to March/2014. The eligible population represented the 6.2% of the children (n=714) who were identified at risk of delay through the CDE Test. For inclusion in the study, a block randomization stratified by sex and age group was performed. Each participant included in the study had a diagnostic evaluation using the Battelle Development Inventory, 2 nd edition. From the 355 participants included with risk of delay, 65.9% were male and 80.2% were from rural areas; 6.5% were false positives (Total Development Quotient ˃90) and 6.8% did not have any domain with delay (Domain Developmental Quotient <80). The proportion of delay for each domain was as follows: communication 82.5%; cognitive 80.8%; social-personal 33.8%; motor 55.5%; and adaptive 41.7%. There were significant differences in the percentages of delay both by age and by domain/subdomain evaluated. In 93.2% of the participants, developmental delay was corroborated in at least one domain evaluated. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  7. Accuracy, risk and the intrinsic value of diagnostic imaging: a review of the cost-utility literature.

    PubMed

    Otero, Hansel J; Fang, Chi H; Sekar, Meera; Ward, Robert J; Neumann, Peter J

    2012-05-01

    The aim of this study was to systematically review the reporting of the value of imaging unrelated to treatment consequences and test characteristics in all imaging-related published cost-utility analyses (CUAs) in the medical literature. All CUAs published between 1976 and 2008 evaluating diagnostic imaging technologies contained in the CEA Registry, a publicly available comprehensive database of health related CUAs, were screened. Publication characteristics, imaging modality, and the inclusion of test characteristics including accuracy, costs, risks, and the potential value unrelated to treatment consequences (eg, reassurance or anxiety) were assessed. Ninety-six published CUAs evaluating 155 different imaging technologies were included in the final sample; 27 studies were published in imaging-specialized journals. Fifty-two studies (54%) evaluated the performance of a single imaging modality, while 44 studies (46%) compared two or more different imaging modalities. The most common areas of interest were cardiovascular (45%) and neuroradiology (17%). Forty-two technologies (27%) concerned ultrasound, while 34 (22%) concerned magnetic resonance. Seventy-nine (51%) technologies used ionizing radiation. Test accuracy was reported or calculated for 90% (n = 133 and n = 5, respectively) and assumed perfect (reference test or gold-standard test without alternative testing strategy to capture false-negatives and false-positives) for 8% (n = 12) of technologies. Only 22 studies (23%) assessing 40 imaging technologies (26%) considered inconclusive or indeterminate results. The risk of testing was reported for 32 imaging technologies (21%). Fifteen studies (16%) considered the value of diagnostic imaging unrelated to treatment. Four studies incorporated it as quality-of-life adjustments, while 10 studies mentioned it only in their discussions or as a limitation. The intrinsic value of imaging (the value of imaging unrelated to treatment) has not been appropriately defined or incorporated in the existing cost-utility literature, which could be due to a lack of evidence on the issue. Thus, more research is needed on metrics for a more comprehensive evaluation of diagnostic imaging. Similarly, the incorporation of variations in imaging tests accuracy, inconclusive results and associated risks has lacked uniformity in the cost-utility literature. Acknowledgment of these characteristics in future cost-utility publications will enhance their value and provide results that more closely resemble routine clinical practice. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  8. Costs of unstructured investigation of unexplained syncope: insights from a micro-costing analysis of the observational PICTURE registry.

    PubMed

    Edvardsson, Nils; Wolff, Claudia; Tsintzos, Stelios; Rieger, Guido; Linker, Nicholas J

    2015-07-01

    The observational PICTURE (Place of Reveal In the Care pathway and Treatment of patients with Unexplained Recurrent Syncope) registry enrolled 570 patients with unexplained syncope, documented their care pathway and the various tests they underwent before the insertion of an implantable loop recorder (ILR). The aims were to describe the extent and cost of diagnostic tests performed before the implant. Actual costs of 17 predefined diagnostic tests were characterized based on a combination of data from PICTURE and a micro-costing study performed at a medium-sized UK university hospital in the UK. The median cost of diagnostic tests per patient was £1114 (95% CI £995-£1233). As many patients received more than the median number of tests, the mean expenditure per patient was higher with £1613 (95% CI £1494-£1732), and for 10% of the patients the cost exceeded £3539. Tests were frequently repeated, and early use of specific and expensive tests was common. In the 12% of patients with types of tests entirely within the recommendations for an initial evaluation before ILR implant, the mean cost was £710. Important opportunities to reduce test-related costs before an ILR implant were identified, e.g. by more appropriate use of tests recommended in the initial evaluation, by decreasing repetition of tests, and by avoiding early use of specialized and expensive tests. A structured multidisciplinary approach would be the best model to achieve an optimal outcome. © The Author 2015. Published by Oxford University Press on behalf of the European Society of Cardiology.

  9. Costs of unstructured investigation of unexplained syncope: insights from a micro-costing analysis of the observational PICTURE registry

    PubMed Central

    Edvardsson, Nils; Wolff, Claudia; Tsintzos, Stelios; Rieger, Guido; Linker, Nicholas J.

    2015-01-01

    Aims The observational PICTURE (Place of Reveal In the Care pathway and Treatment of patients with Unexplained Recurrent Syncope) registry enrolled 570 patients with unexplained syncope, documented their care pathway and the various tests they underwent before the insertion of an implantable loop recorder (ILR). The aims were to describe the extent and cost of diagnostic tests performed before the implant. Methods and results Actual costs of 17 predefined diagnostic tests were characterized based on a combination of data from PICTURE and a micro-costing study performed at a medium-sized UK university hospital in the UK. The median cost of diagnostic tests per patient was £1114 (95% CI £995–£1233). As many patients received more than the median number of tests, the mean expenditure per patient was higher with £1613 (95% CI £1494–£1732), and for 10% of the patients the cost exceeded £3539. Tests were frequently repeated, and early use of specific and expensive tests was common. In the 12% of patients with types of tests entirely within the recommendations for an initial evaluation before ILR implant, the mean cost was £710. Conclusion Important opportunities to reduce test-related costs before an ILR implant were identified, e.g. by more appropriate use of tests recommended in the initial evaluation, by decreasing repetition of tests, and by avoiding early use of specialized and expensive tests. A structured multidisciplinary approach would be the best model to achieve an optimal outcome. PMID:25759408

  10. Utility of Intelligence Tests for Treatment Planning, Classification, and Placement Decisions: Recent Empirical Findings and Future Directions.

    ERIC Educational Resources Information Center

    Gresham, Frank M.; Witt, Joseph C.

    1997-01-01

    Maintains that intelligence tests contribute little to the planning, implementation, and evaluation of instructional interventions for children. Suggests that intelligence tests are not useful in making differential diagnostic and classification determinations for children with mild learning problems and that such testing is not a cost-beneficial…

  11. Case-finding for cognitive impairment among people with Type 2 diabetes in primary care using the Test Your Memory and Self-Administered Gerocognitive Examination questionnaires: the Cog-ID study.

    PubMed

    Koekkoek, P S; Janssen, J; Kooistra, M; Biesbroek, J M; Groeneveld, O; van den Berg, E; Kappelle, L J; Biessels, G J; Rutten, G E H M

    2016-06-01

    To evaluate two cognitive tests for case-finding for cognitive impairment in older patients with Type 2 diabetes. Of 1243 invited patients with Type 2 diabetes, aged ≥70 years, 228 participated in a prospective cohort study. Exclusion criteria were: diagnosis of dementia; previous investigation at a memory clinic; and inability to write or read. Patients first filled out two self-administered cognitive tests (Test Your Memory and Self-Administered Gerocognitive Examination). Secondly, a general practitioner, blinded to Test Your Memory and Self-Administered Gerocognitive Examination scores, performed a structured evaluation using the Mini-Mental State Examination. Subsequently, patients suspected of cognitive impairment (on either the cognitive tests or general practitioner evaluation) and a random sample of 30% of patients not suspected of cognitive impairment were evaluated at a memory clinic. Diagnostic accuracy and area under the curve were determined for the Test Your Memory, Self-Administered Gerocognitive Examination and general practitioner evaluation compared with a memory clinic evaluation to detect cognitive impairment (mild cognitive impairment or dementia). A total of 44 participants were diagnosed with cognitive impairment. The Test Your Memory and Self-Administered Gerocognitive Examination questionnaires had negative predictive values of 81 and 85%, respectively. Positive predictive values were 39 and 40%, respectively. The general practitioner evaluation had a negative predictive value of 83% and positive predictive value of 64%. The area under the curve was ~0.70 for all tests. Both the tests evaluated in the present study can easily be used in case-finding strategies for cognitive impairment in patients with Type 2 diabetes in primary care. The Self-Administered Gerocognitive Examination had the best diagnostic accuracy and therefore we would have a slight preference for this test. Applying the Self-Administered Gerocognitive Examination would considerably reduce the number of patients in whom the general practitioner needs to evaluate cognitive functioning to tailor diabetes treatment. © 2015 Diabetes UK.

  12. Diagnostic properties of the methacholine and mannitol bronchial challenge tests: a comparison study.

    PubMed

    Kim, Min-Hye; Song, Woo-Jung; Kim, Tae-Wan; Jin, Hyun-Jung; Sin, You-Seob; Ye, Young-Min; Kim, Sang-Heon; Park, Heung-Woo; Lee, Byung-Jae; Park, Hae-Sim; Yoon, Ho-Joo; Choi, Dong-Chull; Min, Kyung-Up; Cho, Sang-Heon

    2014-08-01

    Airway hyperresponsiveness is a common feature of asthma. Methacholine and mannitol are two representative agonists for bronchial challenge. They have theoretically different mechanisms of action, and may have different diagnostic properties. However, their difference has not been directly evaluated among Korean adults. In this study, we compare the diagnostic properties of methacholine and mannitol bronchial provocation tests. Asthmatic patients and non-asthmatic controls were recruited prospectively from four referral hospitals in Korea. Participants were challenged with each of methacholine and mannitol inhalation on different days. Their diagnostic utility was evaluated by calculating their sensitivity and specificity for asthma diagnosis. Response-dose ratio was also compared. A total of 50 asthmatic adults and 54 controls were enrolled (mean age 43.8 years). The sensitivity and specificity of mannitol challenge (defined by a PD15 of <635 mg) were 48.0% and 92.6%, respectively, whereas those of methacholine (defined by a PC20 of <16 mg/mL) were 42.0% and 98.1%, respectively. Twenty asthmatic participants (24%) showed positive response to a single agonist only. In the receiver operating curve analyses using response-dose ratio values, area under the curve was 0.77 (95% confidence interval (CI): 0.68-0.86) for mannitol, and 0.89 (95% CI: 0.83-0.95) for methacholine. The correlations between log- transformed mannitol and methacholine response-dose ratios were significant but moderate (r = 0.683, P < 0.001). The present study demonstrated overall similar diagnostic properties of two diagnostic tests, but also suggested their intercomplementary roles for asthma. The clinical trial registration number at ClinicalTrial.gov is NCT02104284. © 2014 Asian Pacific Society of Respirology.

  13. Progress towards implementation of ACT malaria case-management in public health facilities in the Republic of Sudan: a cluster-sample survey

    PubMed Central

    2012-01-01

    Background Effective malaria case-management based on artemisinin-based combination therapy (ACT) and parasitological diagnosis is a major pillar within the 2007-2012 National Malaria Strategic Plan in the Sudan. Three years after the launch of the strategy a health facility survey was undertaken to evaluate case-management practices and readiness of the health facilities and health workers to implement a new malaria case-management strategy. Methods A cross-sectional, cluster sample survey was undertaken at public health facilities in 15 states of Sudan. Data were collected using quality-of-care assessment methods. The main outcomes were the proportions of facilities with ACTs and malaria diagnostics; proportions of health workers exposed to malaria related health systems support activities; and composite and individual indicators of case-management practices for febrile outpatients stratified by age, availability of ACTs and diagnostics, use of malaria diagnostics, and test result. Results We evaluated 244 facilities, 294 health workers and 1,643 consultations for febrile outpatients (425 < 5 years and 1,218 ≥ 5 years). Health facility and health worker readiness was variable: chloroquine was available at only 5% of facilities, 73% stocked recommended artesunate and sulfadoxine/pyrimethamine (AS+SP), 51% had the capacity to perform parasitological diagnosis, 53% of health workers had received in-service training on ACTs, 24% were trained in the use of malaria Rapid Diagnostic Tests, and 19% had received a supervisory visit including malaria case-management. At all health facilities 46% of febrile patients were parasitologically tested and 35% of patients were both, tested and treated according to test result. At facilities where AS+SP and malaria diagnostics were available 66% of febrile patients were tested and 51% were both, tested and treated according to test result. Among test positive patients 64% were treated with AS+SP but 24% were treated with artemether monotherapy. Among test negative patients only 17% of patients were treated for malaria. The majority of ACT dispensing and counseling practices were suboptimal. Conclusions Five years following change of the policy from chloroquine to ACTs and 3 years before the end of the new malaria strategic plan chloroquine was successfully phased out from public facilities in Sudan, however, an important gap remained in the availability of ACTs, diagnostic capacities and coverage with malaria case-management activities. The national scale-up of diagnostics, using the findings of this survey as well as future qualitative research, should present an opportunity not only to expand existing testing capacities but also to implement effective support interventions to bridge the health systems gaps and support corrective case-management measures, including the discontinuation of artemether monotherapy treatment. PMID:22221821

  14. Detection of spring viraemia of carp virus (SVCV) by loop-mediated isothermal amplification (LAMP) in koi carp, Cyprinus carpio L

    USGS Publications Warehouse

    Shivappa, R.B.; Savan, R.; Kono, T.; Sakai, M.; Emmenegger, E.; Kurath, G.; Levine, Jay F.

    2008-01-01

    Spring viraemia of carp virus (SVCV) is a rhabdovirus associated with systemic illness and mortality in cyprinids. Several diagnostic tests are available for detection of SVCV. However, most of these tests are time consuming and are not well adapted for field-based diagnostics. In this study, a diagnostic tool for SVCV detection based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) has been developed. Based on the nucleotide sequence of the glycoprotein (G) gene of SVCV North Carolina (NC) isolate, four sets (each set containing two outer and two inner) of primers were designed. Temperature and time conditions were optimized to 65 ??C and 60 min, respectively, for LAMP and RT-LAMP using one primer set. In vitro specificity was evaluated using four different strains of fish rhabdoviruses and RT-LAMP was found to be specific to SVCV. Serial dilutions of SVCV NC isolate was used to evaluate the in vitro sensitivity of RT-LAMP. Sensitivity of the assays was similar to RT-PCR and detected SVCV even at the lowest dilution of 10 1 TCID50 mL-1. The ability of RT-LAMP to detect SVCV from infected carp was also tested and the assay detected SVCV from all infected fish. The isothermal temperature requirements, high specificity and sensitivity, and short incubation time of the RT-LAMP assay make it an excellent choice as a field diagnostic test for SVCV. ?? 2008 The Authors.

  15. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    PubMed

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  16. Hybrid Bearing Prognostic Test Rig

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Certo, Joseph M.; Handschuh, Robert F.; Dimofte, Florin

    2005-01-01

    The NASA Glenn Research Center has developed a new Hybrid Bearing Prognostic Test Rig to evaluate the performance of sensors and algorithms in predicting failures of rolling element bearings for aeronautics and space applications. The failure progression of both conventional and hybrid (ceramic rolling elements, metal races) bearings can be tested from fault initiation to total failure. The effects of different lubricants on bearing life can also be evaluated. Test conditions monitored and recorded during the test include load, oil temperature, vibration, and oil debris. New diagnostic research instrumentation will also be evaluated for hybrid bearing damage detection. This paper summarizes the capabilities of this new test rig.

  17. The Diagnostic and Prognostic Value of Hematological and Chemical Abnormalities in Soft Tissue Sarcoma: A Comparative Study in Patients with Benign and Malignant Soft Tissue Tumors.

    PubMed

    Ariizumi, Takashi; Kawashima, Hiroyuki; Ogose, Akira; Sasaki, Taro; Hotta, Tetsuo; Hatano, Hiroshi; Morita, Tetsuro; Endo, Naoto

    2018-01-01

    The value of routine blood tests in malignant soft tissue tumors remains uncertain. To determine if these tests can be used for screening, the routine pretreatment blood test findings were retrospectively investigated in 359 patients with benign and malignant soft tissue tumors. Additionally, the prognostic potential of pretreatment blood abnormalities was evaluated in patients with soft tissue sarcomas. We compared clinical factors and blood tests findings between patients with benign and malignant soft tissue tumors using univariate and multivariate analysis. Subsequently, patients with malignant tumors were divided into two groups based on blood test reference values, and the prognostic significance of each parameter was evaluated. In the univariate analysis, age, tumor size, and tumor depth were significant clinical diagnostic factors. Significant increases in the granulocyte count, C-reactive protein (CRP) level, erythrocyte sedimentation rate (ESR), and γ-glutamyl transpeptidase (γ-GTP) levels were found in patients with malignant soft tissue tumors. Multiple logistic regression showed that tumor size and ESR were independent factors that predicted malignant soft tissue tumors. The Kaplan-Meier survival analysis revealed that granulocyte counts, γ-GTP levels, and CRP levels correlated significantly with overall survival. Thus, pretreatment routine blood tests are useful diagnostic and prognostic markers for diagnosing soft tissue sarcoma. © 2018 by the Association of Clinical Scientists, Inc.

  18. Impact of target organ damage assessment in the evaluation of global risk in patients with essential hypertension.

    PubMed

    Viazzi, Francesca; Leoncini, Giovanna; Parodi, Denise; Ratto, Elena; Vettoretti, Simone; Vaccaro, Valentina; Parodi, Angelica; Falqui, Valeria; Tomolillo, Cinzia; Deferrari, Giacomo; Pontremoli, Roberto

    2005-03-01

    Accurate assessment of cardiovascular risk is a key step toward optimizing the treatment of hypertensive patients. We analyzed the impact and cost-effectiveness of routine, thorough assessment of target organ damage (TOD) in evaluating risk profile in hypertension. A total of 380 never-treated patients with essential hypertension underwent routine work-up plus evaluation of albuminuria and ultrasonography of cardiac and vascular structures. The impact of these tests on risk stratification, as indicated by European Society of Hypertension-European Society of Cardiology guidelines, was assessed in light of their cost and sensitivity. The combined use of all of these tests greatly improved the detection of TOD, therefore leading to the identification of a higher percentage of patients who were at high/very high risk, as compared with those who were detected by routine clinical work-up (73% instead of 42%; P < 0.0001). Different signs of TOD only partly cluster within the same subgroup of patients; thus, all three tests should be performed to maximize the sensitivity of the evaluation process. The diagnostic algorithm yielding the lowest cost per detected case of TOD is the search for microalbuminuria, followed by echocardiography and then carotid ultrasonography. Adopting lower cut-off values to define microalbuminuria allows us to optimize further the cost-effectiveness of diagnostic algorithms. In conclusion, because of its low cost and widespread availability, measuring albuminuria is an attractive and cost-effective screening test that is especially suitable as the first step in the large-scale diagnostic work-up of hypertensive patients.

  19. PROMISE of Coronary CT Angiography: Precise and Accurate Diagnosis and Prognosis in Coronary Artery Disease.

    PubMed

    Thomas, Dustin M; Branch, Kelley R; Cury, Ricardo C

    2016-04-01

    Coronary computed tomography angiography (CCTA) is a rapidly growing and powerful diagnostic test that offers a great deal of precision with respect to diagnosing coronary artery disease (CAD). Guideline statements for patients with stable ischemic heart disease have recommended CCTA for only a limited portion of intermediate-risk patients who have relative or absolute contraindications for exercise or vasodilator stress testing. The publication of two large, prospective randomized clinical trials, the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial are likely to expand these indications. These new data from large trials, in addition to other studies, show that CCTA is highly sensitive for the detection of CAD, identifies high-risk patients for cardiac events based on extent or plaque morphology of CAD that would not be identified by other noninvasive means, and provides significantly greater diagnostic certainty for proper treatment, including referral for invasive coronary angiography with revascularization more appropriately. Superior diagnostic accuracy and prognostic data with CCTA, when compared with other functional stress tests, may result in a reduction in unnecessary downstream testing and cost savings. In addition, newer CCTA applications hold the promise of providing a complete evaluation of a patient's coronary anatomy as well as a per-vessel ischemic evaluation. This review focuses on the interval knowledge obtained from newer data on CCTA in patients with stable ischemic heart disease, primarily focusing on the contributions of the Prospective Multicenter Imaging Study for Evaluation of Chest Pain and the Scottish Computed Tomography of the Heart Trial.

  20. Evaluation of the Effect of Diagnostic Molecular Testing on the Surgical Decision-Making Process for Patients With Thyroid Nodules.

    PubMed

    Noureldine, Salem I; Najafian, Alireza; Aragon Han, Patricia; Olson, Matthew T; Genther, Dane J; Schneider, Eric B; Prescott, Jason D; Agrawal, Nishant; Mathur, Aarti; Zeiger, Martha A; Tufano, Ralph P

    2016-07-01

    Diagnostic molecular testing is used in the workup of thyroid nodules. While these tests appear to be promising in more definitively assigning a risk of malignancy, their effect on surgical decision making has yet to be demonstrated. To investigate the effect of diagnostic molecular profiling of thyroid nodules on the surgical decision-making process. A surgical management algorithm was developed and published after peer review that incorporated individual Bethesda System for Reporting Thyroid Cytopathology classifications with clinical, laboratory, and radiological results. This algorithm was created to formalize the decision-making process selected herein in managing patients with thyroid nodules. Between April 1, 2014, and March 31, 2015, a prospective study of patients who had undergone diagnostic molecular testing of a thyroid nodule before being seen for surgical consultation was performed. The recommended management undertaken by the surgeon was then prospectively compared with the corresponding one in the algorithm. Patients with thyroid nodules who did not undergo molecular testing and were seen for surgical consultation during the same period served as a control group. All pertinent treatment options were presented to each patient, and any deviation from the algorithm was recorded prospectively. To evaluate the appropriateness of any change (deviation) in management, the surgical histopathology diagnosis was correlated with the surgery performed. The study cohort comprised 140 patients who underwent molecular testing. Their mean (SD) age was 50.3 (14.6) years, and 75.0% (105 of 140) were female. Over a 1-year period, 20.3% (140 of 688) had undergone diagnostic molecular testing before surgical consultation, and 79.7% (548 of 688) had not undergone molecular testing. The surgical management deviated from the treatment algorithm in 12.9% (18 of 140) with molecular testing and in 10.2% (56 of 548) without molecular testing (P = .37). In the group with molecular testing, the surgical management plan of only 7.9% (11 of 140) was altered as a result of the molecular test. All but 1 of those patients were found to be overtreated relative to the surgical histopathology analysis. Molecular testing did not significantly affect the surgical decision-making process in this study. Among patients whose treatment was altered based on these markers, there was evidence of overtreatment.

  1. Evaluation of an Intervention Instructional Program to Facilitate Understanding of Basic Particle Concepts among Students Enrolled in Several Levels of Study

    ERIC Educational Resources Information Center

    Treagust, David F.; Chandrasegaran, A. L.; Zain, Ahmad N. M.; Ong, Eng Tek; Karpudewan, Mageswary; Halim, Lilia

    2011-01-01

    The efficacy of an intervention instructional program was evaluated to facilitate understanding of particle theory concepts among students (N = 190) using a diagnostic instrument consisting of eleven two-tier multiple-choice items in a pre-test--post-test design. The students involved were high school students, undergraduates and postgraduates…

  2. Cost-effectiveness of tubal patency tests.

    PubMed

    Verhoeve, H R; Moolenaar, L M; Hompes, P; van der Veen, F; Mol, B W J

    2013-04-01

    Guidelines are not in agreement on the most effective diagnostic scenario for tubal patency testing; therefore, we evaluated the cost-effectiveness of invasive tubal testing in subfertile couples compared with no testing and treatment. Cost-effectiveness analysis. Decision analytic framework. Computer-simulated cohort of subfertile women. We evaluated six scenarios: (1) no tests and no treatment; (2) immediate treatment without tubal testing; (3) delayed treatment without tubal testing; (4) hysterosalpingogram (HSG), followed by immediate or delayed treatment, according to diagnosis (tailored treatment); (5) HSG and a diagnostic laparoscopy (DL) in case HSG does not prove tubal patency, followed by tailored treatment; and (6) DL followed by tailored treatment. Expected cumulative live births after 3 years. Secondary outcomes were cost per couple and the incremental cost-effectiveness ratio. For a 30-year-old woman with otherwise unexplained subfertility for 12 months, 3-year cumulative live birth rates were 51.8, 78.1, 78.4, 78.4, 78.6 and 78.4%, and costs per couple were €0, €6968, €5063, €5410, €5405 and €6163 for scenarios 1, 2, 3, 4, 5 and 6, respectively. The incremental cost-effectiveness ratios compared with scenario 1 (reference strategy), were €26,541, €19,046, €20,372, €20,150 and €23,184 for scenarios 2, 3, 4, 5 and 6, respectively. Sensitivity analysis showed the model to be robust over a wide range of values for the variables. The most cost-effective scenario is to perform no diagnostic tubal tests and to delay in vitro fertilisation (IVF) treatment for at least 12 months for women younger than 38 years old, and to perform no tubal tests and start immediate IVF treatment from the age of 39 years. If an invasive diagnostic test is planned, HSG followed by tailored treatment, or a DL if HSG shows no tubal patency, is more cost-effective than DL. © 2013 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2013 RCOG.

  3. Diagnostic accuracy of patch test in children with food allergy.

    PubMed

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Quantitative polymerase chain reaction (PCR) for detection of aquatic animal pathogens in a diagnostic laboratory setting

    USGS Publications Warehouse

    Purcell, Maureen K.; Getchell, Rodman G.; McClure, Carol A.; Weber, S.E.; Garver, Kyle A.

    2011-01-01

    Real-time, or quantitative, polymerase chain reaction (qPCR) is quickly supplanting other molecular methods for detecting the nucleic acids of human and other animal pathogens owing to the speed and robustness of the technology. As the aquatic animal health community moves toward implementing national diagnostic testing schemes, it will need to evaluate how qPCR technology should be employed. This review outlines the basic principles of qPCR technology, considerations for assay development, standards and controls, assay performance, diagnostic validation, implementation in the diagnostic laboratory, and quality assurance and control measures. These factors are fundamental for ensuring the validity of qPCR assay results obtained in the diagnostic laboratory setting.

  5. Serving the Needs of Various Groups of Stakeholders.

    ERIC Educational Resources Information Center

    Geva-May, Iris; Peretz, Hannah

    1991-01-01

    The extent to which evaluation results answer different stakeholders' needs was explored in the evaluation of a business English course at Van Leer Institute for the Development of Executive Assistants in Tel-Aviv (Israel), using diagnostic tests. Students (n=52), teachers, curriculum team, and administrators could use the evaluation results. (SLD)

  6. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories

    PubMed Central

    Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N’Faly; Martel, Lise D.; Dahourou, Anicet George

    2017-01-01

    Background Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Methods and findings Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. Conclusions The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation. PMID:29190713

  7. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    PubMed

    VanSteelandt, Amanda; Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N'Faly; Martel, Lise D; Dahourou, Anicet George

    2017-01-01

    Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  8. Evaluation of the Performance of Five Diagnostic Tests for Fasciola hepatica Infection in Naturally Infected Cattle Using a Bayesian No Gold Standard Approach.

    PubMed

    Mazeri, Stella; Sargison, Neil; Kelly, Robert F; Bronsvoort, Barend M deC; Handel, Ian

    2016-01-01

    The clinical and economic importance of fasciolosis has been recognised for centuries, yet diagnostic tests available for cattle are far from perfect. Test evaluation has mainly been carried out using gold standard approaches or under experimental settings, the limitations of which are well known. In this study, a Bayesian no gold standard approach was used to estimate the diagnostic sensitivity and specificity of five tests for fasciolosis in cattle. These included detailed liver necropsy including gall bladder egg count, faecal egg counting, a commercially available copro-antigen ELISA, an in-house serum excretory/secretory antibody ELISA and routine abattoir liver inspection. In total 619 cattle slaughtered at one of Scotland's biggest abattoirs were sampled, during three sampling periods spanning summer 2013, winter 2014 and autumn 2014. Test sensitivities and specificities were estimated using an extension of the Hui Walter no gold standard model, where estimates were allowed to vary between seasons if tests were a priori believed to perform differently for any reason. The results of this analysis provide novel information on the performance of these tests in a naturally infected cattle population and at different times of the year where different levels of acute or chronic infection are expected. Accurate estimates of sensitivity and specificity will allow for routine abattoir liver inspection to be used as a tool for monitoring the epidemiology of F. hepatica as well as evaluating herd health planning. Furthermore, the results provide evidence to suggest that the copro-antigen ELISA does not cross-react with Calicophoron daubneyi rumen fluke parasites, while the serum antibody ELISA does.

  9. [The model of perioperative risk assessment in elderly patients - interim analysis].

    PubMed

    Grabowska, Izabela; Ścisło, Lucyna; Pietruszka, Szymon; Walewska, Elzbieta; Paszko, Agata; Siarkiewicz, Benita; Richter, Piotr; Budzyński, Andrzej; Szczepanik, Antoni M

    2017-04-21

    Demographic changes in contemporary society require implementation of proper perioperative care of elderly patients due to an increased risk of perioperative complications in this group. Preoperative assessment of health status identifies risks and enables preventive interventions, improving outcomes of surgical treatment. The Comprehensive Geriatric Assessment contains numerous diagnostic tests and consultations, which is expensive and difficult to use in everyday practice. The development of a simplified model of perioperative assessment of elderly patients will help identifying the group of patients who require further diagnostic workup. The aim of the study is to evaluate the usefulness of the tests used in a proposed model of perioperative risk assessment in elderly patients. In a group of 178 patients older than 64 years admitted for surgical procedures, a battery of tests was performed. The proposed model of perioperative risk assessment included: Charlson Comorbidity Index, ADL (activities of daily living), TUG test (timed "up and go" test), MNA (mini nutritional assessment), AMTS (abbreviated mental test score), spirometry measurement of respiratory muscle strength (Pimax, Pemax). Distribution of abnormal results of each test has been analysed. The Charlson Index over 6 points was recorded in 10.1% of patients (15.1% in cancer patients). Abnormal result of the TUG test was observed in 32.1%. The risk of malnutrition in MNA test has been identified in 29.7% (39.2% in cancer patients). Abnormal test results at the level of 10-30% indicate potential diagnostic value of Charlson Comorbidity Index, TUG test and MNA in the evaluation of perioperative risk in elderly patients.

  10. Imaging techniques for evaluation of the uterine cavity and endometrium in premenopausal patients before minimally invasive surgery.

    PubMed

    Dueholm, Margit; Lundorf, Erik; Olesen, Frede

    2002-06-01

    A literature review compared the diagnostic effectiveness and accuracy of transvaginal sonography (TVS) hysterosonographic examination (HSE), hysteroscopy (HY), and magnetic resonance imaging (MRI) in abnormalities of the uterine cavity and endometrium in premenopausal patients referred to surgery and women with abnormal uterine bleeding. The studies varied much in terms of patient selection, number of observers, blinding and experience of observers, and definition of abnormality criteria. The diagnostic effectiveness of the techniques reviewed varied: TVS only reached intermediate quality levels as a diagnostic tool for exclusion of uterine cavity abnormalities and no data support that MRI, TVS, HY, or HSE may exclude hyperplasia without concomitant endometrial sampling. HY and HSE were equally effective and apparently outperformed TVS, especially for identification of polyps. However, all techniques carried a significant number of false positive results. MRI does not satisfy current diagnostic demands for detection of endometrial abnormalities, but it is sufficiently accurate for submucous myoma (SM) evaluation. TVS, HSE, and HY carry much observer variation as opposed to MRI. In experienced hands TVS should be a first choice modality, but its precision and consistency fall short of current needs and it should therefore be supplemented by other techniques. HSE or HY performed by experienced clinicians should be used as supplements to TVS for exclusion of polyps. MRI can be recommended as the first choice modality for exact evaluation of SM uterine in-growth before advanced minimal invasive treatment of myomas. Clinicians should be aware that modern imaging techniques may yield highly idiosyncratic results when used by inexperienced staff, and efforts should be made to reduce such observer variation. Obstetricians & Gynecologists, Family Physicians. After completion of this article, the reader will be able to describe the diagnostic strengths and weaknesses of the various diagnostic tests in the evaluation of abnormal uterine bleeding and to compare the accuracy of each test to the others.

  11. Aminopenicillin-associated exanthem: lymphocyte transformation testing revisited.

    PubMed

    Trautmann, A; Seitz, C S; Stoevesandt, J; Kerstan, A

    2014-12-01

    The lymphocyte transformation test (LTT) has been promoted as in-vitro test for diagnosis of drug hypersensitivity. For determination of statistical LTT sensitivity, series of patients with clinically uniform reactions followed by complete drug hypersensitivity work-up are mandatory. Assessment of LTT specificity requires control patients who tolerated exposure to the drug studied. To prospectively determine the diagnostic value of the LTT in a clinically and diagnostically well-defined series of patients. Patients with exanthematous skin eruptions after ampicillin (AMP) intake were included in this study. After exclusion or confirmation of delayed-onset allergic AMP hypersensitivity by skin and provocation testing, two independent LTTs were performed: one standard LTT and a modified LTT with additional anti-CD3/anti-CD28 monoclonal antibody stimulation. By testing, delayed-onset allergic AMP hypersensitivity was diagnosed in 11 patients and definitely ruled out in 26. The standard LTT reached a diagnostic sensitivity of 54.5% while the modified LTT yielded 72.7%. However, the methodical test modification resulted in a decline of specificity from 92.3% (standard LTT) to 76.9%. In cases of AMP-associated exanthems, the diagnostic value of the LTT compared with routine allergy testing is limited. When evaluating such exanthems, provocation testing remains the gold standard. Delayed reading of intradermal skin tests remains most useful to avoid positive provocation reactions. © 2014 John Wiley & Sons Ltd.

  12. An embedded barcode for "connected" malaria rapid diagnostic tests.

    PubMed

    Scherr, Thomas F; Gupta, Sparsh; Wright, David W; Haselton, Frederick R

    2017-03-29

    Many countries are shifting their efforts from malaria control to disease elimination. New technologies will be necessary to meet the more stringent demands of elimination campaigns, including improved quality control of malaria diagnostic tests, as well as an improved means for communicating test results among field healthcare workers, test manufacturers, and national ministries of health. In this report, we describe and evaluate an embedded barcode within standard rapid diagnostic tests as one potential solution. This information-augmented diagnostic test operates on the familiar principles of traditional lateral flow assays and simply replaces the control line with a control grid patterned in the shape of a QR (quick response) code. After the test is processed, the QR code appears on both positive or negative tests. In this report we demonstrate how this multipurpose code can be used not only to fulfill the control line role of test validation, but also to embed test manufacturing details, serve as a trigger for image capture, enable registration for image analysis, and correct for lighting effects. An accompanying mobile phone application automatically captures an image of the test when the QR code is recognized, decodes the QR code, performs image processing to determine the concentration of the malarial biomarker histidine-rich protein 2 at the test line, and transmits the test results and QR code payload to a secure web portal. This approach blends automated, sub-nanomolar biomarker detection, with near real-time reporting to provide quality assurance data that will help to achieve malaria elimination.

  13. THE DIAGNOSTIC ACCURACY OF THE LEVER SIGN FOR DETECTING ANTERIOR CRUCIATE LIGAMENT INJURY

    PubMed Central

    Anderson, Amanda; Watson, Seth; Dimeff, Robert J.

    2017-01-01

    Background An alternative physical examination procedure for evaluating the integrity of the anterior cruciate ligament (ACL) has been proposed in the literature but has not been validated in a broad population of patients with a symptomatic complaint of knee pain for its diagnostic value. Purpose To investigate the diagnostic accuracy of the Lever Sign to detect ACL tears and compare the results to Lachman testing in both supine and prone positions. Study design Prospective, blinded, diagnostic accuracy study. Methods Sixty-two consecutive patients with a complaint of knee pain were independently evaluated for the status of the ACL's integrity with the Lever Sign and the Lachman test in a prone and supine by a blinded examiner before any other diagnostic assessments were completed. Results Twenty-four of the 60 patients included in the analysis had a torn ACL resulting in a prevalence of 40%. The sensitivity of the Lever Sign, prone, and supine Lachman tests were 38, 83, and 67 % respectively and the specificity was 72, 89, and 97% resulting in positive likelihood ratios of 1.4, 7.5, and 24 and negative likelihood ratios of 0.86, 0.19, and 0.34 respectively. The positive predictive values were 47, 83, and 94% and the negative predictive values were 63, 89, and 81% respectively. The diagnostic odds ratios were 1.6, 40, and 70 with a number needed to diagnose of 10.3, 1.4, and 1.6 respectively. Conclusions The results of this study suggest that Lever Sign, in isolation, does not accurately detect the status of the ACL. During the clinical examination, the Lever Sign should be used as an adjunct to the gold standard assessment technique of anterior tibial translation assessment as employed in the Lachman tests in either prone or supine position. Level of Evidence 2 PMID:29234557

  14. Evaluation of the diagnostic value of serologic microagglutination testing and a polymerase chain reaction assay for diagnosis of acute leptospirosis in dogs in a referral center.

    PubMed

    Fraune, Claudia Kümmerle; Schweighauser, Ariane; Francey, Thierry

    2013-05-15

    To determine the diagnostic value of a serologic microagglutination test (MAT) and a PCR assay on urine and blood for the diagnosis of leptospirosis in dogs with acute kidney injury (AKI). Cross-sectional study. Animals-76 dogs with AKI in a referral hospital (2008 to 2009). Dogs' leptospirosis status was defined with a paired serologic MAT against a panel of 11 Leptospira serovars as leptospirosis-associated (n = 30) or nonleptospirosis-associated AKI (12). In 34 dogs, convalescent serologic testing was not possible, and leptospirosis status was classified as undetermined. The diagnostic value of the MAT single acute or convalescent blood sample was determined in dogs in which leptospirosis status could be classified. The diagnostic value of a commercially available genus-specific PCR assay was evaluated by use of 36 blood samples and 20 urine samples. Serologic acute testing of an acute blood sample had a specificity of 100% (95% CI, 76% to 100%), a sensitivity of 50% (33% to 67%), and an accuracy of 64% (49% to 77%). Serologic testing of a convalescent blood sample had a specificity of 92% (65% to 99%), a sensitivity of 100% (87% to 100%), and an accuracy of 98% (88% to 100%). Results of the Leptospira PCR assay were negative for all samples from dogs for which leptospirosis status could be classified. Serologic MAT results were highly accurate for diagnosis of leptospirosis in dogs, despite a low sensitivity for early diagnosis. In this referral setting of dogs pretreated with antimicrobials, testing of blood and urine samples with a commercially available genus-specific PCR assay did not improve early diagnosis.

  15. Diagnostic performance of a rapid in-clinic test for the detection of Canine Parvovirus under different storage conditions and vaccination status.

    PubMed

    Kantere, Maria C; Athanasiou, Labrini V; Spyrou, Vassiliki; Kyriakis, Constantinos S; Kontos, Vassilios; Chatzopoulos, Dimitrios C; Tsokana, Constantina N; Billinis, Charalambos

    2015-04-01

    Canine parvovirus (CPV) is one of the most common causes of acute haemorrhagic enteritis in young dogs, while clinical diagnosis is often indecisive. The aim of our study was to evaluate the diagnostic accuracy of an in-clinic rapid test in the detection of CPV infection in dogs. To this end, we compared the Rapid Diagnostic Kit of Canine Parvovirus, Coronavirus and Rotavirus antigen (Quicking(®)) to PCR, which is considered as the most reliable diagnostic method. A total of 78 duplicated faecal samples were collected from diarrhoeic dogs. Vaccination history within a month prior to the onset of diarrhoea was reported for 12 of the sampled dogs. The rapid diagnostic test was performed in 23 of the faecal samples directly, while the rest were placed into a sterile cotton tipped swab suitable for collection and transportation of viruses (Sigma Σ-VCM(®)) and stored at -20 °C. The sensitivity of the Quicking rapid diagnostic test compared to PCR in the total number of samples, in samples from non-vaccinated dogs and in samples tested directly after collection were 22.22% (95% CI: 13.27-33.57%), 26.67% (95% CI: 16.08-39.66%) and 76.47% (95% CI: 50.10-93.04%) respectively, while the specificity of the test was 100% in any case. In conclusion, negative results do not exclude parvoenteritis from the differential diagnosis, especially in dogs with early vaccination history, but a positive result almost certainly indicates CPV infection. An improved sensitivity may be expected when the test is performed immediately. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Use of a pLDH-based dipstick in the diagnostic and therapeutic follow-up of malaria patients in Mali

    PubMed Central

    2011-01-01

    Background Malaria is a major public health problem in Mali and diagnosis is typically based on microscopy. Microscopy requires a well trained technician, a reliable power source, a functioning microscope and adequate supplies. The scarcity of resources of community health centres (CHC) does not allow for such a significant investment in only one aspect of malaria control. In this context, Rapid Diagnostic Tests (RDTs) may improve case management particularly in remote areas. Methods This multicentre study included 725 patients simultaneously screened with OptiMal-IT test and thick smears for malaria parasite detection. While evaluating the therapeutic efficacy of choroquine in 2 study sites, we compared the diagnostic values of thick smear microscopy to OptiMal-IT test applying the WHO 14 days follow-up scheme using samples collected from 344 patients. Results The sensitivity and the specificity of OptiMal-IT compared to thick smear was 97.2% and 95.4%, whereas the positive and negative predictive values were 96.7 and 96.1%, respectively. The percent agreement between the two diagnostic tests was 0.93. The two tests were comparable in detecting malaria at day 0, day 3 and day 14. The only difference was observed at day 7 due to high gametocytemia. Subjectively, health care providers found OptiMal-IT easier to use and store under field conditions. Conclusion OptiMal-IT test revealed similar results when compared to microscopy which is considered the gold standard for malaria diagnostics. The test was found to have a short processing time and was easier to use. These advantages may improve malaria case management by providing a diagnostic and drug efficacy follow-up tool to peripheral health centres with limited resources. PMID:22114867

  17. INCLEN diagnostic tool for attention deficit hyperactivity disorder (INDT-ADHD): development and validation.

    PubMed

    Mukherjee, Sharmila; Aneja, Satinder; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K

    2014-06-01

    To develop and validate INCLEN Diagnostic Tool for Attention Deficit Hyperactivity Disorder (INDT-ADHD). Diagnostic test evaluation by cross sectional design. Tertiary care pediatric centers. 156 children aged 65-117 months. After randomization, INDT-ADHD and Connors 3 Parent Rating Scale (C3PS) were administered, followed by an expert evaluation by DSM-IV-TR diagnostic criteria. Psychometric evaluation of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. INDT-ADHD had 18 items that quantified symptoms and impairment. Attention deficit hyperactivity disorder was identified in 57, 87 and 116 children by expert evaluation, INDT-ADHD and C3PS, respectively. Psychometric parameters of INDT-ADHD for differentiating attention deficit hyperactivity disorder and normal children were: sensitivity 87.7%, specificity 97.2%, positive predictive value 98.0% and negative predictive value 83.3%, whereas for differentiating from other neuro-developmental disorders were 87.7%, 42.9%, 58.1% and 79.4%, respectively. Internal consistency was 0.91. INDT-ADHD has a 4-factor structure explaining 60.4% of the variance. Convergent validity with Conner's Parents Rating Scale was moderate (r =0.73, P= 0.001). INDT-ADHD is suitable for diagnosing attention deficit hyperactivity disorder in Indian children between the ages of 6 to 9 years.

  18. The role of diagnostic laboratories in support of animal disease surveillance systems.

    PubMed

    Zepeda, C

    2007-01-01

    Diagnostic laboratories are an essential component of animal disease surveillance systems. To understand the occurrence of disease in populations, surveillance systems rely on random or targeted surveys using three approaches: clinical, serological and virological surveillance. Clinical surveillance is the basis for early detection of disease and is usually centered on the detection of syndromes and clinical findings requiring confirmation by diagnostic laboratories. Although most of the tests applied usually perform to an acceptable standard, several have not been properly validated in terms of their diagnostic sensitivity and specificity. Sensitivity and specificity estimates can vary according to local conditions and, ideally, should be determined by national laboratories where the tests are to be applied. The importance of sensitivity and specificity estimates in the design and interpretation of statistically based surveys and risk analysis is fundamental to establish appropriate disease control and prevention strategies. The World Organisation for Animal Health's (OIE) network of reference laboratories acts as centers of expertise for the diagnosis of OIE listed diseases and have a role in promoting the validation of OIE prescribed tests for international trade. This paper discusses the importance of the epidemiological evaluation of diagnostic tests and the role of the OIE Reference Laboratories and Collaborating Centres in this process.

  19. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    USGS Publications Warehouse

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  20. Bootstrap-based procedures for inference in nonparametric receiver-operating characteristic curve regression analysis.

    PubMed

    Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G

    2018-03-01

    Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.

  1. The diagnostic performance of perfusion MRI for differentiating glioma recurrence from pseudoprogression: A meta-analysis.

    PubMed

    Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo

    2017-03-01

    The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.

  2. INCLEN Diagnostic Tool for Autism Spectrum Disorder (INDT-ASD): development and validation.

    PubMed

    Juneja, Monica; Mishra, Devendra; Russell, Paul S S; Gulati, Sheffali; Deshmukh, Vaishali; Tudu, Poma; Sagar, Rajesh; Silberberg, Donald; Bhutani, Vinod K; Pinto, Jennifer M; Durkin, Maureen; Pandey, Ravindra M; Nair, M K C; Arora, Narendra K

    2014-05-01

    To develop and validate INCLEN Diagnostic Tool for Autism Spectrum Disorder (INDT-ASD). Diagnostic test evaluation by cross sectional design. Four tertiary pediatric neurology centers in Delhi and Thiruvanthapuram, India. Children aged 2-9 years were enrolled in the study. INDT-ASD and Childhood Autism Rating Scale (CARS) were administered in a randomly decided sequence by trained psychologist, followed by an expert evaluation by DSM-IV TR diagnostic criteria (gold standard). Psychometric parameters of diagnostic accuracy, validity (construct, criterion and convergent) and internal consistency. 154 children (110 boys, mean age 64.2 mo) were enrolled. The overall diagnostic accuracy (AUC=0.97, 95% CI 0.93, 0.99; P<0.001) and validity (sensitivity 98%, specificity 95%, positive predictive value 91%, negative predictive value 99%) of INDT-ASD for Autism spectrum disorder were high, taking expert diagnosis using DSM-IV-TR as gold standard. The concordance rate between the INDT-ASD and expert diagnosis for 'ASD group' was 82.52% [Cohen's k=0.89; 95% CI (0.82, 0.97); P=0.001]. The internal consistency of INDT-ASD was 0.96. The convergent validity with CARS (r = 0.73, P= 0.001) and divergent validity with Binet-Kamat Test of intelligence (r = -0.37; P=0.004) were significantly high. INDT-ASD has a 4-factor structure explaining 85.3% of the variance. INDT-ASD has high diagnostic accuracy, adequate content validity, good internal consistency high criterion validity and high to moderate convergent validity and 4-factor construct validity for diagnosis of Autistm spectrum disorder.

  3. Benchmarking Diagnostic Algorithms on an Electrical Power System Testbed

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Narasimhan, Sriram; Poll, Scott; Garcia, David; Wright, Stephanie

    2009-01-01

    Diagnostic algorithms (DAs) are key to enabling automated health management. These algorithms are designed to detect and isolate anomalies of either a component or the whole system based on observations received from sensors. In recent years a wide range of algorithms, both model-based and data-driven, have been developed to increase autonomy and improve system reliability and affordability. However, the lack of support to perform systematic benchmarking of these algorithms continues to create barriers for effective development and deployment of diagnostic technologies. In this paper, we present our efforts to benchmark a set of DAs on a common platform using a framework that was developed to evaluate and compare various performance metrics for diagnostic technologies. The diagnosed system is an electrical power system, namely the Advanced Diagnostics and Prognostics Testbed (ADAPT) developed and located at the NASA Ames Research Center. The paper presents the fundamentals of the benchmarking framework, the ADAPT system, description of faults and data sets, the metrics used for evaluation, and an in-depth analysis of benchmarking results obtained from testing ten diagnostic algorithms on the ADAPT electrical power system testbed.

  4. Contribution of diagnostic tests for the etiological assessment of uveitis, data from the ULISSE study (Uveitis: Clinical and medicoeconomic evaluation of a standardized strategy of the etiological diagnosis).

    PubMed

    Grumet, Pierre; Kodjikian, Laurent; de Parisot, Audrey; Errera, Marie-Hélène; Sedira, Neila; Heron, Emmanuel; Pérard, Laurent; Cornut, Pierre-Loïc; Schneider, Christelle; Rivière, Sophie; Ollé, Priscille; Pugnet, Grégory; Cathébras, Pascal; Manoli, Pierre; Bodaghi, Bahram; Saadoun, David; Baillif, Stéphanie; Tieulie, Nathalie; Andre, Marc; Chiambaretta, Frédéric; Bonin, Nicolas; Bielefeld, Philip; Bron, Alain; Mouriaux, Frédéric; Bienvenu, Boris; Vicente, Stéphanie; Bin, Sylvie; Labetoulle, Marc; Broussolle, Christiane; Jamilloux, Yvan; Decullier, Evelyne; Sève, Pascal

    2018-04-01

    ULISSE is the only study that prospectively assessed the efficiency of a standardized strategy, compared to an open strategy for the etiologic diagnosis of uveitis. Our aim was to evaluate the diagnostic yield of the tests prescribed in the ULISSE study to clarify their relevance. ULISSE is a non-inferiority, prospective, multicenter and cluster randomized study. The standardized strategy is a two-steps strategy: in the first step, common standard tests were performed, and in the second step, tests were guided by the clinical and anatomic type of uveitis. We reported the relevance of the diagnostic tests used in the standardized strategy, as well as the profitability of the tests that were prescribed to more than twenty patients in each group. Based on diagnostic criteria, either an ophthalmologist, or an internist, established the profitability of a test by considering whether the test lead to a diagnosis or not. Among the 676 patients included (standardized 303; open 373), a diagnosis was made for 152 (50.4%) in the standardized group and 203 (54.4%) in the open group. The most common entities were HLA-B27 associated uveitis (22%), spondyloarthritis (11%), sarcoidosis (18%), tuberculosis (10.7%) and herpes virus infections (8.5%). Among the first step's systematic tests, tuberculin skin test was the most contributive investigation (17.1%), followed by chest X-ray (8.4%), C reactive protein and ESR (6.6% and 5.1%), complete blood count (2.2%) and VDRL (2.0%). The second step's most often contributive tests were: HLA B27 (56.3%), chest-CT (30.3%) and angiotensin converting enzyme (ACE) (16.5%). HLA B27 and ACE were significantly more contributive in the standardized group than in the open group. Immunological tests were never contributive. Among the free investigations, or among the investigations guided by clinical or paraclinical findings, the most often contributive tests were: Quantiferon® (24%), electrophoresis of serum protein (7.8%) and sacroiliac imagery (46.4%). Intracellular serologies (1.7%), serum calcium (2.1%) and hepatic tests (3.3%) were exceptionally contributive. Among the third intention tests, labial salivary gland biopsies were contributive in 17.9% of cases, but the profitability of other invasive investigations (anterior chamber tap, vitrectomy, bronchoscopy and lumbar puncture) or specialized imagery (18F-FDG PET, Brain MRI) could not be determined since these test were rarely performed. Only a few diagnostic tests are useful for the etiological assessment of uveitis. They are often cheap, simple, more often guided by the clinical findings, and lead to an etiological diagnosis in most patients. On the other hand, some tests are never or exceptionally contributive, such as immunological tests or intracellular serologies. Further studies are required to evaluate the profitability of third intention imagery and invasive investigations. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. [Value of desmopressin stimulation test and high dose dexamethasone suppression testin the etiologic diagnosis of ACTH dependent Cushing's syndrome].

    PubMed

    Zhang, Weiwei; Yu, Yerong; Tan, Huiwen; Wang, Chun; Li, Jianwei; An, Zhenmei; Liu, Yuping

    2016-03-22

    To investigate the value of desmopressin (DDAVP) stimulation test and high dose dexamethasone suppression test (HDDST) in establishing the cause of ACTH dependent Cushing's syndrome. The clinical data of patients with ACTH dependent Cushing's syndrome at West China Hospital from January 1, 2010 to September 30, 2015 was analyzed. The sensitivity and specificity of DDAVP stimulation test, HDDST, and the diagnostic accordance rate when the two tests were combined, were evaluated based on the diagnostic gold standard. A total of 85 patients with Cushing's disease and 10 patients with ectopic ACTH syndrome were included. The sensitivity and specificity of DDAVP stimulation test were 87% and 5/5, respectively, whereas those of HDDST were 79% and 8/10, respectively. The standard high dose dexamethasone suppression test showed a higher sensitivity than overnight 8 mg dexamethasone suppression test. When the two tests had consistent results, the diagnostic accordance rate was 100%. DDAVP stimulation test and HDDST are both efficient modalities for the diagnosis of Cushing's Disease and ectopic ACTH syndrome. The accuracy of diagnosis can be further improved by combining the two tests.

  6. Comparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields

    PubMed Central

    Rowe, Fiona J.; Rowlands, Alison

    2014-01-01

    Purpose. To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. Methods. Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of test duration and type of visual field classification for Octopus versus Goldmann perimetry. Results were independently graded for presence/absence of field defect and for type and location of defect. Statistical evaluation comprised of ANOVA and paired t test for evaluation of parametric data with Bonferroni adjustment. Bland Altman and Kappa tests were used for measurement of agreement between data. Results. Octopus 5°/sec perimetry had comparable test duration to Goldmann perimetry. Octopus perimetry reliably detected type and location of visual field loss with visual fields matched to Goldmann results in 88.8% of results (K = 0.775). Conclusions. Kinetic perimetry requires individual tailoring to ensure accuracy. Octopus perimetry was reproducible for presence/absence of visual field defect. Our screening protocol when using Octopus perimetry is 5°/sec for determining boundaries of peripheral isopters and 3°/sec for blind spot mapping with further evaluation of area of field loss for defect depth and size. PMID:24587983

  7. Comprehensive evaluation of the child with intellectual disability or global developmental delays.

    PubMed

    Moeschler, John B; Shevell, Michael

    2014-09-01

    Global developmental delay and intellectual disability are relatively common pediatric conditions. This report describes the recommended clinical genetics diagnostic approach. The report is based on a review of published reports, most consisting of medium to large case series of diagnostic tests used, and the proportion of those that led to a diagnosis in such patients. Chromosome microarray is designated as a first-line test and replaces the standard karyotype and fluorescent in situ hybridization subtelomere tests for the child with intellectual disability of unknown etiology. Fragile X testing remains an important first-line test. The importance of considering testing for inborn errors of metabolism in this population is supported by a recent systematic review of the literature and several case series recently published. The role of brain MRI remains important in certain patients. There is also a discussion of the emerging literature on the use of whole-exome sequencing as a diagnostic test in this population. Finally, the importance of intentional comanagement among families, the medical home, and the clinical genetics specialty clinic is discussed. Copyright © 2014 by the American Academy of Pediatrics.

  8. Evaluation of the Cepheid® Xpert®C. difficile binary toxin (BT) diagnostic assay.

    PubMed

    McGovern, Alan M; Androga, Grace O; Moono, Peter; Collins, Deirdre A; Foster, Niki F; Chang, Barbara J; Riley, Thomas V

    2018-06-01

    Strains of Clostridium difficile producing only binary toxin (CDT) are found commonly in animals but not humans. However, human diagnostic tests rarely look for CDT. The Cepheid Xpert C. difficile BT assay detects CDT with equal sensitivity (≥92%) in human and animal faecal samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Pain symptoms and stooling patterns do not drive diagnostic costs for children with functional abdominal pain and irritable bowel syndrome in primary or tertiary care.

    PubMed

    Lane, Mariella M; Weidler, Erica M; Czyzewski, Danita I; Shulman, Robert J

    2009-03-01

    The objectives of this study were to (1) compare the cost of medical evaluation for children with functional abdominal pain or irritable bowel syndrome brought to a pediatric gastroenterologist versus children who remained in the care of their pediatrician, (2) compare symptom characteristics for the children in primary versus tertiary care, and (3) examine if symptom characteristics predicted the cost of medical evaluation. Eighty-nine children aged 7 to 10 years with functional abdominal pain or irritable bowel syndrome seen by a gastroenterologist (n = 46) or seen only by a pediatrician (n = 43) completed daily pain and stool diaries for 2 weeks. Mothers provided retrospective reports of their children's symptoms in the previous year. Cost of medical evaluation was calculated via chart review of diagnostic tests and application of prices as if the patients were self-pay. Child-reported diary data reflected no significant group differences with respect to pain, interference with activities, or stool characteristics. In contrast, mothers of children evaluated by a gastroenterologist viewed their children as having higher maximum pain intensity in the previous year. Excluding endoscopy costs, cost of medical evaluation was fivefold higher for children evaluated by a gastroenterologist, with higher cost across blood work, stool studies, breath testing, and diagnostic imaging. Symptom characteristics did not predict cost of care for either group. Despite the lack of difference in symptom characteristics between children in primary and tertiary care, a notable differential in cost of evaluation exists in accordance with level of care. Symptom characteristics do not seem to drive diagnostic evaluation in either primary or tertiary care. Given the lack of differences in child-reported symptoms and the maternal perspective that children evaluated by a gastroenterologist had more severe pain, we speculate that parent perception of child symptoms may be a primary factor in seeking tertiary care.

  10. Diagnostic Testing and Interpretation of Tests for Autoimmunity

    PubMed Central

    Castro, Christine; Gourley, Mark

    2010-01-01

    Laboratory testing is of great value when evaluating a patient with a suspected autoimmune disease. The results can confirm a diagnosis, estimate disease severity, aid in assessing prognosis and are useful to follow disease activity. Components of the laboratory exam include complete blood count with differential, comprehensive metabolic panel, inflammatory markers, autoantibodies, and flow cytometry. This chapter discusses these components and includes a discussion about organ-specific immunologic diseases where immunological laboratory testing is employed. Comprehensive laboratory evaluation of a suspected autoimmune illness in conjunction with a thorough clinical evaluation provides a better understanding of a patient's immunologic disease. PMID:20061009

  11. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites

    PubMed Central

    Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure

    2017-01-01

    Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437

  12. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.

    PubMed

    Kosack, Cara S; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng'ang'a, Anne; Andre, Bita; Zahinda, Jean-Paul Bn; Fransen, Katrien; Page, Anne-Laure

    2017-07-03

    We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy.

  13. Prognostic relevance of motor talent predictors in early adolescence: A group- and individual-based evaluation considering different levels of achievement in youth football.

    PubMed

    Höner, Oliver; Votteler, Andreas

    2016-12-01

    In the debate about the usefulness of motor diagnostics in the talent identification process, the prognostic validity for tests conducted in early adolescence is of critical interest. Using a group- and individual-based statistical approach, this prospective cohort study evaluated a nationwide assessment of speed abilities and technical skills regarding its relevance for future achievement levels. The sample consisted of 22,843 U12-players belonging to the top 4% in German football. The U12-results in five tests served as predictors for players' selection levels in U16-U19 (youth national team, regional association, youth academy, not selected). Group-mean differences proved the prognostic relevance for all predictors. Low individual selection probabilities demonstrated limited predictive values, while excellent test results proved their particular prognostic relevance. Players scoring percentile ranks (PRs) ≥ 99 had a 12 times higher chance to become youth national team players than players scoring PR < 99. Simulating increasing score cut-off values not only enhanced specificity (correctly identified non-talents) but also led to lower sensitivity (loss of talents). Extending the current research, these different approaches revealed the ambiguity of the diagnostics' prognostic relevance, representing both the usefulness and several pitfalls of nationwide diagnostics. Therefore, the present diagnostics can support but not substitute for coaches' subjective decisions for talent identification, and multidisciplinary designs are required.

  14. A Framework to Debug Diagnostic Matrices

    NASA Technical Reports Server (NTRS)

    Kodal, Anuradha; Robinson, Peter; Patterson-Hine, Ann

    2013-01-01

    Diagnostics is an important concept in system health and monitoring of space operations. Many of the existing diagnostic algorithms utilize system knowledge in the form of diagnostic matrix (D-matrix, also popularly known as diagnostic dictionary, fault signature matrix or reachability matrix) gleaned from physical models. But, sometimes, this may not be coherent to obtain high diagnostic performance. In such a case, it is important to modify this D-matrix based on knowledge obtained from other sources such as time-series data stream (simulated or maintenance data) within the context of a framework that includes the diagnostic/inference algorithm. A systematic and sequential update procedure, diagnostic modeling evaluator (DME) is proposed to modify D-matrix and wrapper logic considering least expensive solution first. This iterative procedure includes conditions ranging from modifying 0s and 1s in the matrix, or adding/removing the rows (failure sources) columns (tests). We will experiment this framework on datasets from DX challenge 2009.

  15. European Respiratory Society guidelines for the diagnosis of primary ciliary dyskinesia.

    PubMed

    Lucas, Jane S; Barbato, Angelo; Collins, Samuel A; Goutaki, Myrofora; Behan, Laura; Caudri, Daan; Dell, Sharon; Eber, Ernst; Escudier, Estelle; Hirst, Robert A; Hogg, Claire; Jorissen, Mark; Latzin, Philipp; Legendre, Marie; Leigh, Margaret W; Midulla, Fabio; Nielsen, Kim G; Omran, Heymut; Papon, Jean-Francois; Pohunek, Petr; Redfern, Beatrice; Rigau, David; Rindlisbacher, Bernhard; Santamaria, Francesca; Shoemark, Amelia; Snijders, Deborah; Tonia, Thomy; Titieni, Andrea; Walker, Woolf T; Werner, Claudius; Bush, Andrew; Kuehni, Claudia E

    2017-01-01

    The diagnosis of primary ciliary dyskinesia is often confirmed with standard, albeit complex and expensive, tests. In many cases, however, the diagnosis remains difficult despite the array of sophisticated diagnostic tests. There is no "gold standard" reference test. Hence, a Task Force supported by the European Respiratory Society has developed this guideline to provide evidence-based recommendations on diagnostic testing, especially in light of new developments in such tests, and the need for robust diagnoses of patients who might enter randomised controlled trials of treatments. The guideline is based on pre-defined questions relevant for clinical care, a systematic review of the literature, and assessment of the evidence using the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach. It focuses on clinical presentation, nasal nitric oxide, analysis of ciliary beat frequency and pattern by high-speed video-microscopy analysis, transmission electron microscopy, genotyping and immunofluorescence. It then used a modified Delphi survey to develop an algorithm for the use of diagnostic tests to definitively confirm and exclude the diagnosis of primary ciliary dyskinesia; and to provide advice when the diagnosis was not conclusive. Finally, this guideline proposes a set of quality criteria for future research on the validity of diagnostic methods for primary ciliary dyskinesia. Copyright ©ERS 2017.

  16. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    PubMed

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  17. Pediatric Baseline Patch Test Series: Initial Findings of the Pediatric Contact Dermatitis Workgroup.

    PubMed

    Yu, JiaDe; Atwater, Amber Reck; Brod, Bruce; Chen, Jennifer K; Chisolm, Sarah S; Cohen, David E; de la Feld, Salma; Gaspari, Anthony A; Martin, Kari Lyn; Montanez-Wiscovich, Marjorie; Sheehan, Michael; Silverberg, Nanette; Lugo-Somolinos, Aida; Thakur, Binod K; Watsky, Kalman; Jacob, Sharon E

    2018-06-21

    Allergic contact dermatitis is a challenging diagnostic problem in children. Although epicutaneous patch testing is the diagnostic standard for confirmation of contact sensitization, it is less used in children by dermatologists treating children, pediatric dermatologists, and pediatricians, when compared with adult practitioners. The aim of the study was to create and evaluate standardization of a pediatric patch test series for children older than 6 years. We surveyed dermatologists and allergists conducting epicutaneous patch testing in children attending the 2017 American Contact Dermatitis Society meeting held in Washington, DC. This was followed by discussion of collected data and consensus review by a pediatric contact dermatitis working group at the conference. A baseline pediatric patch test panel was established through working group consensus.

  18. Clinical Practice Guideline for Diagnostic Testing for Adult Obstructive Sleep Apnea: An American Academy of Sleep Medicine Clinical Practice Guideline

    PubMed Central

    Kapur, Vishesh K.; Auckley, Dennis H.; Chowdhuri, Susmita; Kuhlmann, David C.; Mehra, Reena; Ramar, Kannan; Harrod, Christopher G.

    2017-01-01

    Introduction: This guideline establishes clinical practice recommendations for the diagnosis of obstructive sleep apnea (OSA) in adults and is intended for use in conjunction with other American Academy of Sleep Medicine (AASM) guidelines on the evaluation and treatment of sleep-disordered breathing in adults. Methods: The AASM commissioned a task force of experts in sleep medicine. A systematic review was conducted to identify studies, and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) process was used to assess the evidence. The task force developed recommendations and assigned strengths based on the quality of evidence, the balance of benefits and harms, patient values and preferences, and resource use. In addition, the task force adopted foundational recommendations from prior guidelines as “good practice statements”, that establish the basis for appropriate and effective diagnosis of OSA. The AASM Board of Directors approved the final recommendations. Recommendations: The following recommendations are intended as a guide for clinicians diagnosing OSA in adults. Under GRADE, a STRONG recommendation is one that clinicians should follow under most circumstances. A WEAK recommendation reflects a lower degree of certainty regarding the outcome and appropriateness of the patient-care strategy for all patients. The ultimate judgment regarding propriety of any specific care must be made by the clinician in light of the individual circumstances presented by the patient, available diagnostic tools, accessible treatment options, and resources. Good Practice Statements: Diagnostic testing for OSA should be performed in conjunction with a comprehensive sleep evaluation and adequate follow-up. Polysomnography is the standard diagnostic test for the diagnosis of OSA in adult patients in whom there is a concern for OSA based on a comprehensive sleep evaluation. Recommendations: We recommend that clinical tools, questionnaires and prediction algorithms not be used to diagnose OSA in adults, in the absence of polysomnography or home sleep apnea testing. (STRONG)We recommend that polysomnography, or home sleep apnea testing with a technically adequate device, be used for the diagnosis of OSA in uncomplicated adult patients presenting with signs and symptoms that indicate an increased risk of moderate to severe OSA. (STRONG)We recommend that if a single home sleep apnea test is negative, inconclusive, or technically inadequate, polysomnography be performed for the diagnosis of OSA. (STRONG)We recommend that polysomnography, rather than home sleep apnea testing, be used for the diagnosis of OSA in patients with significant cardiorespiratory disease, potential respiratory muscle weakness due to neuromuscular condition, awake hypoventilation or suspicion of sleep related hypoventilation, chronic opioid medication use, history of stroke or severe insomnia. (STRONG)We suggest that, if clinically appropriate, a split-night diagnostic protocol, rather than a full-night diagnostic protocol for polysomnography be used for the diagnosis of OSA. (WEAK)We suggest that when the initial polysomnogram is negative and clinical suspicion for OSA remains, a second polysomnogram be considered for the diagnosis of OSA. (WEAK) Citation: Kapur VK, Auckley DH, Chowdhuri S, Kuhlmann DC, Mehra R, Ramar K, Harrod CG. Clinical practice guideline for diagnostic testing for adult obstructive sleep apnea: an American Academy of Sleep Medicine clinical practice guideline. J Clin Sleep Med. 2017;13(3):479–504. PMID:28162150

  19. Diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B: a meta-analysis of diagnostic test.

    PubMed

    Yin, Zhi; Zou, Jin; Li, Qiongxuan; Chen, Lizhang

    2017-04-04

    This study is aimed at evaluating the diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B through a meta-analysis of diagnostic test. We conducted a comprehensive search in the Pubmed, Embase, Web of Science, and Chinese National Knowledge Infrastructure before October 31, 2016. Stata 14.0 software was used for calculation and statistical analyses. We used the sensitivity, specificity, positive and negative likelihood ratio (PLR, NLR), diagnostic odds ratio (DOR) and 95% confidence intervals (CIs) to evaluate the diagnostic value of FIB-4 for liver fibrosis in patients with hepatitis B. Twenty-six studies were included in the final analyses, with a total of 8274 individuals. The pooled parameters are calculated from all studies: sensitivity of 0.69 (95%CI:0.63-0.75), specificity of 0.81 (95%CI: 0.73-0.87), PLR of 3.63 (95%CI:2.66-4.94), NLR of 0.38 (95%CI:0.32-0.44), DOR of 9.57 (95%CI: 6.67-13.74), and area under the curve (AUC) of 0.80 (95%CI: 0.76-0.83). We also conducted subgroup based on the range of cut-off values. Results from subgroup analysis showed that cut-off was the source of heterogeneity in the present study. The sensitivity and specificity of cut-off>2 were 0.69 and 0.95 with the AUC of 0.90 (95%CI: 0.87-0.92). The overall diagnostic value of FIB-4 is not very high for liver fibrosis in patients with hepatitis B. However, the diagnostic value is affected by the cut-off value. FIB-4 has relatively high diagnostic value for detecting liver fibrosis in patients with hepatitis B when the diagnostic threshold value is more than 2.0.

  20. Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma.

    PubMed

    Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S

    2015-08-01

    To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.

  1. Methodology and preliminary results of a systematic literature review of ante-mortem and post-mortem diagnostic tests for bovine tuberculosis.

    PubMed

    Downs, Sara H; Parry, Jessica E; Upton, Paul A; Broughan, Jennifer M; Goodchild, Anthony V; Nuñez-Garcia, Javier; Greiner, Matthias; Abernethy, Darrell A; Cameron, Angus R; Cook, Alasdair J; de la Rua-Domenech, Ricardo; Gunn, Jane; Pritchard, Elizabeth; Rhodes, Shelley; Rolfe, Simon; Sharp, Michael; Vordermeier, H Martin; Watson, Eamon; Welsh, Michael; Whelan, Adam O; Woolliams, John A; More, Simon J; Clifton-Hadley, Richard S

    2018-05-01

    A systematic review was conducted to identify studies with data for statistical meta-analyses of sensitivity (Se) and specificity (Sp) of ante-mortem and post-mortem diagnostic tests for bovine tuberculosis (bTB) in cattle. Members of a working group (WG) developed and tested search criteria and developed a standardised two-stage review process, to identify primary studies with numerator and denominator data for test performance and an agreed range of covariate data. No limits were applied to year, language, region or type of test in initial searches of electronic databases. In stage 1, titles and available abstracts were reviewed. References that complied with stage 1 selection criteria were reviewed in entirety and agreed data were extracted from references that complied with stage 2 selection criteria. At stage 1, 9782 references were reviewed and 261 (2.6%) passed through to stage 2 where 215 English language references were each randomly allocated to two of 18 WG reviewers and 46 references in other languages were allocated to native speakers. Agreement regarding eligibility between reviewers of the same reference at stage 2 was moderate (Kappa statistic = 0.51) and a resolution procedure was conducted. Only 119 references (published 1934-2009) were identified with eligible performance estimates for one or more of 14 different diagnostic test types; despite a comprehensive search strategy and the global impact of bTB. Searches of electronic databases for diagnostic test performance data were found to be nonspecific with regard to identifying references with diagnostic test Se or Sp data. Guidelines for the content of abstracts to research papers reporting diagnostic test performance are presented. The results of meta-analyses of the sensitivity and specificity of the tests, and of an evaluation of the methodological quality of the source references, are presented in accompanying papers (Nuñez-Garcia et al., 2017; Downs et al., 2017). Copyright © 2017. Published by Elsevier B.V.

  2. Joint confidence region estimation for area under ROC curve and Youden index.

    PubMed

    Yin, Jingjing; Tian, Lili

    2014-03-15

    In the field of diagnostic studies, the area under the ROC curve (AUC) serves as an overall measure of a biomarker/diagnostic test's accuracy. Youden index, defined as the overall correct classification rate minus one at the optimal cut-off point, is another popular index. For continuous biomarkers of binary disease status, although researchers mainly evaluate the diagnostic accuracy using AUC, for the purpose of making diagnosis, Youden index provides an important and direct measure of the diagnostic accuracy at the optimal threshold and hence should be taken into consideration in addition to AUC. Furthermore, AUC and Youden index are generally correlated. In this paper, we initiate the idea of evaluating diagnostic accuracy based on AUC and Youden index simultaneously. As the first step toward this direction, this paper only focuses on the confidence region estimation of AUC and Youden index for a single marker. We present both parametric and non-parametric approaches for estimating joint confidence region of AUC and Youden index. We carry out extensive simulation study to evaluate the performance of the proposed methods. In the end, we apply the proposed methods to a real data set. Copyright © 2013 John Wiley & Sons, Ltd.

  3. Costs and clinical outcomes for non-invasive versus invasive diagnostic approaches to patients with suspected in-stent restenosis.

    PubMed

    Min, James K; Hasegawa, James T; Machacz, Susanne F; O'Day, Ken

    2016-02-01

    This study compared costs and clinical outcomes of invasive versus non-invasive diagnostic evaluations for patients with suspected in-stent restenosis (ISR) after percutaneous coronary intervention. We developed a decision model to compare 2 year diagnosis-related costs for patients who presented with suspected ISR and were evaluated by: (1) invasive coronary angiography (ICA); (2) non-invasive stress testing strategy of myocardial perfusion imaging (MPI) with referral to ICA based on MPI; (3) coronary CT angiography-based testing strategy with referral to ICA based on CCTA. Costs were modeled from the payer's perspective using 2014 Medicare rates. 56 % of patients underwent follow-up diagnostic testing over 2 years. Compared to ICA, MPI (98.6 %) and CCTA (98.1 %) exhibited lower rates of correct diagnoses. Non-invasive strategies were associated with reduced referrals to ICA and costs compared to an ICA-based strategy, with diagnostic costs lower for CCTA than MPI. Overall 2-year costs were highest for ICA for both metallic as well as BVS stents ($1656 and $1656, respectively) when compared to MPI ($1444 and $1411) and CCTA. CCTA costs differed based upon stent size and type, and were highest for metallic stents >3.0 mm followed by metallic stents <3.0 mm, BVS < 3.0 mm and BVS > 3.0 mm ($1466 vs. $1242 vs. $855 vs. $490, respectively). MPI for suspected ISR results in lower costs and rates of complications than invasive strategies using ICA while maintaining high diagnostic performance. Depending upon stent size and type, CCTA results in lower costs than MPI.

  4. Meta-analysis of diagnostic accuracy studies accounting for disease prevalence: alternative parameterizations and model selection.

    PubMed

    Chu, Haitao; Nie, Lei; Cole, Stephen R; Poole, Charles

    2009-08-15

    In a meta-analysis of diagnostic accuracy studies, the sensitivities and specificities of a diagnostic test may depend on the disease prevalence since the severity and definition of disease may differ from study to study due to the design and the population considered. In this paper, we extend the bivariate nonlinear random effects model on sensitivities and specificities to jointly model the disease prevalence, sensitivities and specificities using trivariate nonlinear random-effects models. Furthermore, as an alternative parameterization, we also propose jointly modeling the test prevalence and the predictive values, which reflect the clinical utility of a diagnostic test. These models allow investigators to study the complex relationship among the disease prevalence, sensitivities and specificities; or among test prevalence and the predictive values, which can reveal hidden information about test performance. We illustrate the proposed two approaches by reanalyzing the data from a meta-analysis of radiological evaluation of lymph node metastases in patients with cervical cancer and a simulation study. The latter illustrates the importance of carefully choosing an appropriate normality assumption for the disease prevalence, sensitivities and specificities, or the test prevalence and the predictive values. In practice, it is recommended to use model selection techniques to identify a best-fitting model for making statistical inference. In summary, the proposed trivariate random effects models are novel and can be very useful in practice for meta-analysis of diagnostic accuracy studies. Copyright 2009 John Wiley & Sons, Ltd.

  5. Diagnostic accuracy of clinical tests for assessment of hamstring injury: a systematic review.

    PubMed

    Reiman, Michael P; Loudon, Janice K; Goode, Adam P

    2013-04-01

    Systematic literature review. The diagnosis of a hamstring injury has traditionally relied on various clinical measures (eg, palpation, swelling, manual resistance), as well as the use of diagnostic imaging. But a few studies have suggested the use of specific clinical tests that may be helpful for the diagnostic process. To summarize the current literature on the diagnostic accuracy of orthopaedic special tests for hamstring injuries and to determine their clinical utility. A computer-assisted literature search of the MEDLINE, CINAHL, and Embase databases (along with a manual search of grey literature) was conducted using key words related to diagnostic accuracy of hamstring injuries. To be considered for inclusion in the review, the study required (1) patients with hamstring or posterior thigh pain; (2) a cohort, case-control, or cross-sectional design; (3) inclusion of at least 1 clinical examination test used to evaluate hamstring pathology; (4) comparison against an acceptable reference standard; (5) reporting of diagnostic accuracy of the measures (sensitivity [SN], specificity [SP], or likelihood ratios); and (6) publication in English. SN, SP, and positive and negative likelihood ratios were calculated for each diagnostic test. The search strategy identified 602 potential articles, of which only 3 articles met the inclusion criteria, with only 1 of these 3 articles being of high quality. Two of the studies investigated a single special test, whereas the third article examined a composite clinical assessment employing various special tests. The SN values ranged from 0.55 (95% confidence interval [CI]: 0.46, 0.69) for the active range-of-motion test to 1.00 (95% CI: 0.97, 1.00) for the taking-off-the-shoe test. The SP values ranged from 0.03 (95% CI: 0.00, 0.22) for the composite clinical assessment to 1.00 (95% CI: 0.97, 1.00) for the taking-off-the-shoe test, active range-of-motion test, passive range-of-motion test, and resisted range-of-motion test. The use of a single special test demonstrated stronger SP than SN properties, whereas the composite clinical assessment demonstrated stronger SN than SP properties. Very few studies have investigated the utilization of clinical special tests for the diagnosis of hamstring injuries. Further studies of higher quality design are suggested prior to advocating independent clinical utilization of these special tests. Diagnosis, level 3b.

  6. Comparison of visual and automated Deki Reader interpretation of malaria rapid diagnostic tests in rural Tanzanian military health facilities.

    PubMed

    Kalinga, Akili K; Mwanziva, Charles; Chiduo, Sarah; Mswanya, Christopher; Ishengoma, Deus I; Francis, Filbert; Temu, Lucky; Mahikwano, Lucas; Mgata, Saidi; Amoo, George; Anova, Lalaine; Wurrapa, Eyako; Zwingerman, Nora; Ferro, Santiago; Bhat, Geeta; Fine, Ian; Vesely, Brian; Waters, Norman; Kreishman-Deitrick, Mara; Hickman, Mark; Paris, Robert; Kamau, Edwin; Ohrt, Colin; Kavishe, Reginald A

    2018-05-29

    Although microscopy is a standard diagnostic tool for malaria and the gold standard, it is infrequently used because of unavailability of laboratory facilities and the absence of skilled readers in poor resource settings. Malaria rapid diagnostic tests (RDT) are currently used instead of or as an adjunct to microscopy. However, at very low parasitaemia (usually < 100 asexual parasites/µl), the test line on malaria rapid diagnostic tests can be faint and consequently hard to visualize and this may potentially affect the interpretation of the test results. Fio Corporation (Canada), developed an automated RDT reader named Deki Reader™ for automatic analysis and interpretation of rapid diagnostic tests. This study aimed to compare visual assessment and automated Deki Reader evaluations to interpret malaria rapid diagnostic tests against microscopy. Unlike in the previous studies where expert laboratory technicians interpreted the test results visually and operated the device, in this study low cadre health care workers who have not attended any formal professional training in laboratory sciences were employed. Finger prick blood from 1293 outpatients with fever was tested for malaria using RDT and Giemsa-stained microscopy for thick and thin blood smears. Blood samples for RDTs were processed according to manufacturers' instructions automated in the Deki Reader. Results of malaria diagnoses were compared between visual and the automated devise reading of RDT and microscopy. The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively. There was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting.

  7. Protein electrophoresis as a diagnostic and prognostic tool in raptor medicine.

    PubMed

    Tatum, L M; Zaias, J; Mealey, B K; Cray, C; Bossart, G D

    2000-12-01

    Plasma proteins of 139 healthy adult birds of prey from 10 species were separated by electrophoresis to characterize and document normal reference ranges and species-specific electrophoretic patternsand to evaluate the value of this technique for health screening, disease diagnosis, and prognostic indication. Species studied included bald eagle (Haliaeetus leucocephalus), red-tailed hawk (Buteo jamaicensis), barn owl (Tyto alba), great horned owl (Bubo virginianus), turkey vulture (Cathartes aura), Harris' hawk (Parabuteo unicinctus), Stellar's sea eagle (Haliaeetus pelagicus), barred owl (Strix varia), screech owl (Otus asio), and black vulture (Coragyps atratus). Several clinical cases show the diagnostic/therapeutic value of protein electrophoresis in raptors. This study establishes species-specific reference ranges for several birds of prey and discusses the benefit of electrophoresis as a diagnostic technique in health screens, as a diagnostic aid in conjunction with other tests, and as a prognostic indicator in clinical evaluation of raptors.

  8. DEVELOPMENT OF DIAGNOSTIC ANALYTICAL AND MECHANICAL ABILITY TESTS THROUGH FACET DESIGN AND ANALYSIS.

    ERIC Educational Resources Information Center

    GUTTMAN, LOUIS,; SCHLESINGER, I.M.

    METHODOLOGY BASED ON FACET THEORY (MODIFIED SET THEORY) WAS USED IN TEST CONSTRUCTION AND ANALYSIS TO PROVIDE AN EFFICIENT TOOL OF EVALUATION FOR VOCATIONAL GUIDANCE AND VOCATIONAL SCHOOL USE. THE TYPE OF TEST DEVELOPMENT UNDERTAKEN WAS LIMITED TO THE USE OF NONVERBAL PICTORIAL ITEMS. ITEMS FOR TESTING ABILITY TO IDENTIFY ELEMENTS BELONGING TO AN…

  9. Michael's Inform Test of Student Ability (M.I.T.O.S.A.). Tester's Manual.

    ERIC Educational Resources Information Center

    Grafius, Thomas M.

    Michael's Informal Test of Student Ability (MITOSA) is a diagnostic evaluative tool for adult students designed to test nine skills abilities in adult students functioning below a tenth grade level. The nine test sections are approximate reading level, understanding of basic math concepts and symbols, general thinking/reasoning ability, eye-hand…

  10. The poppy seed test for colovesical fistula: big bang, little bucks!

    PubMed

    Kwon, Eric O; Armenakas, Noel A; Scharf, Stephen C; Panagopoulos, Georgia; Fracchia, John A

    2008-04-01

    Diagnosis of a colovesical fistula is often challenging, and usually involves numerous invasive and expensive tests and procedures. The poppy seed test stands out as an exception to this rule. We evaluated the accuracy and cost-effectiveness of various established diagnostic tests used to evaluate a suspected colovesical fistula. We identified 20 prospectively entered patients with surgically confirmed colovesical fistulas between 2000 and 2006. Each patient was evaluated preoperatively with a (51)chromium nuclear study, computerized tomography of the abdomen and pelvis with oral and intravenous contrast medium, and the poppy seed test. Costs were calculated using institutional charges, 2006 Medicare limiting approved charges and the market price, respectively. The z test was used to compare the proportion of patients who tested positive for a fistula with each of these modalities. The chromium study was positive in 16 of 20 patients (80%) at a cost of $490.83 per study. Computerized tomography was positive in 14 of 20 patients (70%) at a cost of $652.92 per study. The poppy seed test was positive in 20 of 20 patients (100%) at a cost of $5.37 per study. The difference in the proportion of patients who tested positive for a fistula on computerized tomography and the poppy seed test was statistically significant (p = 0.03). There was no difference between the chromium group and the computerized tomography or poppy seed group (p = 0.72 and 0.12, respectively). The poppy seed test is an accurate, convenient and inexpensive diagnostic test. It is an ideal initial consideration for evaluating a suspected colovesical fistula.

  11. An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

    NASA Technical Reports Server (NTRS)

    Rinehart, Aidan W.; Simon, Donald L.

    2015-01-01

    This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

  12. An Integrated Architecture for Aircraft Engine Performance Monitoring and Fault Diagnostics: Engine Test Results

    NASA Technical Reports Server (NTRS)

    Rinehart, Aidan W.; Simon, Donald L.

    2014-01-01

    This paper presents a model-based architecture for performance trend monitoring and gas path fault diagnostics designed for analyzing streaming transient aircraft engine measurement data. The technique analyzes residuals between sensed engine outputs and model predicted outputs for fault detection and isolation purposes. Diagnostic results from the application of the approach to test data acquired from an aircraft turbofan engine are presented. The approach is found to avoid false alarms when presented nominal fault-free data. Additionally, the approach is found to successfully detect and isolate gas path seeded-faults under steady-state operating scenarios although some fault misclassifications are noted during engine transients. Recommendations for follow-on maturation and evaluation of the technique are also presented.

  13. Uncertainty evaluation of dead zone of diagnostic ultrasound equipment

    NASA Astrophysics Data System (ADS)

    Souza, R. M.; Alvarenga, A. V.; Braz, D. S.; Petrella, L. I.; Costa-Felix, R. P. B.

    2016-07-01

    This paper presents a model for evaluating measurement uncertainty of a feature used in the assessment of ultrasound images: dead zone. The dead zone was measured by two technicians of the INMETRO's Laboratory of Ultrasound using a phantom and following the standard IEC/TS 61390. The uncertainty model was proposed based on the Guide to the Expression of Uncertainty in Measurement. For the tested equipment, results indicate a dead zone of 1.01 mm, and based on the proposed model, the expanded uncertainty was 0.17 mm. The proposed uncertainty model contributes as a novel way for metrological evaluation of diagnostic imaging by ultrasound.

  14. Multicentre evaluation of a direct agglutination test prototype kit (DAT-LPC) for diagnosis of visceral leishmaniasis.

    PubMed

    Oliveira, E; Oliveira, D; Cardoso, F A; Barbosa, J R; Marcelino, A P; Dutra, T; Araujo, T; Fernandes, L; Duque, D; Rabello, A

    2017-12-01

    In this study, we assessed the sensitivity, specificity, and diagnostic accuracy of a previously developed direct agglutination test (DAT) using a freeze-dried antigen derived from Leishmania infantum promastigotes and composed in a prototype kit for visceral leishmaniasis (VL) diagnosis, named DAT-LPC. To evaluate DAT-LPC reproducibility, the kit was used to analyse 207 serum samples from VL patients and 80 serum samples from patients with other parasitic infections or healthy subjects in four laboratories from different public health institutions in Brazil. DAT-LPC showed sensitivity between 96·2 and 99·5% (P = 0·14), specificity ranging from 96·2 to 97·5% (P = 0·95), and diagnostic accuracy ranging from 96·5 to 99% (P = 0·34). The inter-laboratory reproducibility of qualitative results was classified as excellent (κ index: 0·94-0·97). The reproducibility of the end-titre results in relation to the reference laboratory, ranged from 31 to 85%. These results demonstrate an excellent performance of the DAT-LPC, and validate it for the diagnosis of VL that could replace the immunofluorescent antibody test as the routine diagnostic test in the Brazilian public health system.

  15. Systematic review, meta-analysis and economic modelling of molecular diagnostic tests for antibiotic resistance in tuberculosis.

    PubMed

    Drobniewski, Francis; Cooke, Mary; Jordan, Jake; Casali, Nicola; Mugwagwa, Tendai; Broda, Agnieszka; Townsend, Catherine; Sivaramakrishnan, Anand; Green, Nathan; Jit, Mark; Lipman, Marc; Lord, Joanne; White, Peter J; Abubakar, Ibrahim

    2015-05-01

    Drug-resistant tuberculosis (TB), especially multidrug-resistant (MDR, resistance to rifampicin and isoniazid) disease, is associated with a worse patient outcome. Drug resistance diagnosed using microbiological culture takes days to weeks, as TB bacteria grow slowly. Rapid molecular tests for drug resistance detection (1 day) are commercially available and may promote faster initiation of appropriate treatment. To (1) conduct a systematic review of evidence regarding diagnostic accuracy of molecular genetic tests for drug resistance, (2) conduct a health-economic evaluation of screening and diagnostic strategies, including comparison of alternative models of service provision and assessment of the value of targeting rapid testing at high-risk subgroups, and (3) construct a transmission-dynamic mathematical model that translates the estimates of diagnostic accuracy into estimates of clinical impact. A standardised search strategy identified relevant studies from EMBASE, PubMed, MEDLINE, Bioscience Information Service (BIOSIS), System for Information on Grey Literature in Europe Social Policy & Practice (SIGLE) and Web of Science, published between 1 January 2000 and 15 August 2013. Additional 'grey' sources were included. Quality was assessed using quality assessment of diagnostic accuracy studies version 2 (QUADAS-2). For each diagnostic strategy and population subgroup, a care pathway was constructed to specify which medical treatments and health services that individuals would receive from presentation to the point where they either did or did not complete TB treatment successfully. A total cost was estimated from a health service perspective for each care pathway, and the health impact was estimated in terms of the mean discounted quality-adjusted life-years (QALYs) lost as a result of disease and treatment. Costs and QALYs were both discounted at 3.5% per year. An integrated transmission-dynamic and economic model was used to evaluate the cost-effectiveness of introducing rapid molecular testing (in addition to culture and drug sensitivity testing). Probabilistic sensitivity analysis was performed to evaluate the impact on cost-effectiveness of diagnostic and treatment time delays, diagnosis and treatment costs, and associated QALYs. A total of 8922 titles and abstracts were identified, with 557 papers being potentially eligible. Of these, 56 studies contained sufficient test information for analysis. All three commercial tests performed well when detecting drug resistance in clinical samples, although with evidence of heterogeneity between studies. Pooled sensitivity for GenoType® MTBDRplus (Hain Lifescience, Nehren, Germany) (isoniazid and rifampicin resistance), INNO-LiPA Rif.TB® (Fujirebio Europe, Ghent, Belgium) (rifampicin resistance) and Xpert® MTB/RIF (Cepheid Inc., Sunnyvale, CA, USA) (rifampicin resistance) was 83.4%, 94.6%, 95.4% and 96.8%, respectively; equivalent pooled specificity was 99.6%, 98.2%, 99.7% and 98.4%, respectively. Results of the transmission model suggest that all of the rapid assays considered here, if added to the current diagnostic pathway, would be cost-saving and achieve a reduction in expected QALY loss compared with current practice. GenoType MTBDRplus appeared to be the most cost-effective of the rapid tests in the South Asian population, although results were similar for GeneXpert. In all other scenarios GeneXpert appeared to be the most cost-effective strategy. Rapid molecular tests for rifampicin and isoniazid resistance were sensitive and specific. They may also be cost-effective when added to culture drug susceptibility testing in the UK. There is global interest in point-of-care testing and further work is needed to review the performance of emerging tests and the wider health-economic impact of decentralised testing in clinics and primary care, as well as non-health-care settings, such as shelters and prisons. This study is registered as PROSPERO CRD42011001537. The National Institute for Health Research Health Technology Assessment programme.

  16. Multi-site evaluation of the LN34 pan-lyssavirus real-time RT-PCR assay for post-mortem rabies diagnostics

    PubMed Central

    Dettinger, Lisa; Powell, James W.; Seiders, Melanie; Condori, Rene Edgar Condori; Griesser, Richard; Okogi, Kenneth; Carlos, Maria; Pesko, Kendra; Breckenridge, Mike; Simon, Edson Michael M.; Chu, Maria Yna Joyce V.; Davis, April D.; Brunt, Scott J.; Orciari, Lillian; Yager, Pamela; Carson, William C.; Hartloge, Claire; Saliki, Jeremiah T.; Deldari, Mojgan; Hsieh, Kristina; Wadhwa, Ashutosh; Wilkins, Kimberly; Rabideau, Patricia; Gruhn, Nina; Cadet, Rolain; Isloor, Shrikrishna; Nath, Sujith S.; Joseph, Tomy; Gao, Jinxin; Wallace, Ryan; Reynolds, Mary; Olson, Victoria A.

    2018-01-01

    Rabies is a fatal zoonotic disease that requires fast, accurate diagnosis to prevent disease in an exposed individual. The current gold standard for post-mortem diagnosis of human and animal rabies is the direct fluorescent antibody (DFA) test. While the DFA test has proven sensitive and reliable, it requires high quality antibody conjugates, a skilled technician, a fluorescence microscope and diagnostic specimen of sufficient quality. The LN34 pan-lyssavirus real-time RT-PCR assay represents a strong candidate for rabies post-mortem diagnostics due to its ability to detect RNA across the diverse Lyssavirus genus, its high sensitivity, its potential for use with deteriorated tissues, and its simple, easy to implement design. Here, we present data from a multi-site evaluation of the LN34 assay in 14 laboratories. A total of 2,978 samples (1,049 DFA positive) from Africa, the Americas, Asia, Europe, and the Middle East were tested. The LN34 assay exhibited low variability in repeatability and reproducibility studies and was capable of detecting viral RNA in fresh, frozen, archived, deteriorated and formalin-fixed brain tissue. The LN34 assay displayed high diagnostic specificity (99.68%) and sensitivity (99.90%) when compared to the DFA test, and no DFA positive samples were negative by the LN34 assay. The LN34 assay produced definitive findings for 80 samples that were inconclusive or untestable by DFA; 29 were positive. Five samples were inconclusive by the LN34 assay, and only one sample was inconclusive by both tests. Furthermore, use of the LN34 assay led to the identification of one false negative and 11 false positive DFA results. Together, these results demonstrate the reliability and robustness of the LN34 assay and support a role for the LN34 assay in improving rabies diagnostics and surveillance. PMID:29768505

  17. Meta-analyses of the sensitivity and specificity of ante-mortem and post-mortem diagnostic tests for bovine tuberculosis in the UK and Ireland.

    PubMed

    Nuñez-Garcia, Javier; Downs, Sara H; Parry, Jessica E; Abernethy, Darrell A; Broughan, Jennifer M; Cameron, Angus R; Cook, Alasdair J; de la Rua-Domenech, Ricardo; Goodchild, Anthony V; Gunn, Jane; More, Simon J; Rhodes, Shelley; Rolfe, Simon; Sharp, Michael; Upton, Paul A; Vordermeier, H Martin; Watson, Eamon; Welsh, Michael; Whelan, Adam O; Woolliams, John A; Clifton-Hadley, Richard S; Greiner, Matthias

    2018-05-01

    Bovine Tuberculosis (bTB) in cattle is a global health problem and eradication of the disease requires accurate estimates of diagnostic test performance to optimize their efficiency. The objective of this study was, through statistical meta-analyses, to obtain estimates of sensitivity (Se) and specificity (Sp), for 14 different ante-mortem and post-mortem diagnostic tests for bTB in cattle. Using data from a systematic review of the scientific literature (published 1934-2009) diagnostic Se and Sp were estimated using Bayesian logistic regression models adjusting for confounding factors. Random effect terms were used to account for unexplained heterogeneity. Parameters in the models were implemented using Markov Chain Monte Carlo (MCMC), and posterior distributions for the diagnostic parameters with adjustment for covariates (confounding factors) were obtained using the inverse logit function. Estimates for Se and/or Sp of the tuberculin skin tests and the IFN-γ blood test were compared with estimates published 2010-2015. Median Se for the single intradermal comparative cervical tuberculin skin (SICCT) test (standard interpretation) was 0.50 and Bayesian credible intervals (CrI) were wide (95% CrI 0.26, 0.78). Median Sp for the SICCT test was 1.00 (95% CrI 0.99, 1.00). Estimates for the IFN-γ blood test Bovine Purified Protein Derivative (PPD)-Avian PPD and Early Secreted Antigen target 6 and Culture Filtrate Protein 10 (ESAT-6/CFP10) ESAT6/CFP10 were 0.67 (95% CrI 0.49, 0.82) and 0.78 (95% CrI 0.60, 0.90) respectively for Se, and 0.98 (95% CrI 0.96, 0.99) and 0.99 (95% CrI 0.99, 1.00) for Sp. The study provides an overview of the accuracy of a range of contemporary diagnostic tests for bTB in cattle. Better understanding of diagnostic test performance is essential for the design of effective control strategies and their evaluation. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  18. Validation of the Italian version of the Coma Recovery Scale-Revised (CRS-R).

    PubMed

    Sacco, Simona; Altobelli, Emma; Pistarini, Caterina; Cerone, Davide; Cazzulani, Benedetta; Carolei, Antonio

    2011-01-01

    To validate the Italian version of the Coma Recovery Scale-Revised (CRS-R). Two observers applied the Italian version of the CRS-R to selected patients. On day 1, observer A and B independently scored each patient; the comparison of their observations was used to evaluate inter-observer agreement. On day 2, observer A completed a second evaluation and the comparison of this observation with that obtained on day 1 by the same observer was used to evaluate test-re-test agreement. For each evaluation, also diagnostic impression (vegetative state/minimally conscious state) was reported. Thirty-eight patients were evaluated (mean age ± SD, 58.9 ± 13.8 years). Inter-observer (ρ = 0.81; p < 0.001) as well as test-re-test agreement (ρ = 0.97; p < 0.001) for the total score was high. Inter-observer agreement was excellent for the communication sub-scale, good for the auditory, visual and motor sub-scales and moderate for the oromotor/verbal and arousal sub-scales. Test-re-test agreement was excellent for the visual, motor, oromotor/verbal and communication sub-scales, good for the auditory sub-scale and moderate for the arousal sub-scale. When considering the diagnostic impression, inter-observer agreement was good (κ = 0.75; p < 0.001) and test-re-test agreement was excellent (κ = 0.92; p < 0.001). The Italian version of the CRS-R can be administered reliably and can be also employed to discriminate patients in vegetative and in minimally conscious state.

  19. Evaluation of the Cobas TaqMan MTB test for the detection of Mycobacterium tuberculosis complex according to acid-fast-bacillus smear grades in respiratory specimens.

    PubMed

    Huh, Hee Jae; Koh, Won-Jung; Song, Dong Joon; Ki, Chang-Seok; Lee, Nam Yong

    2015-02-01

    We evaluated the performance of the Cobas TaqMan MTB test (Roche Diagnostics, Basel, Switzerland), stratified by acid-fast bacilli (AFB) smear grades. The sensitivity of this test in smear-positive specimens was >95% in all grades, while that in trace and negative specimens was 85.3% and 34.4%, respectively. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Accuracy of malaria diagnosis by microscopy, rapid diagnostic test, and PCR methods and evidence of antimalarial overprescription in non-severe febrile patients in two Tanzanian hospitals.

    PubMed

    Nicastri, Emanuele; Bevilacqua, Nazario; Sañé Schepisi, Monica; Paglia, Maria G; Meschi, Silvia; Ame, Shaali M; Mohamed, Jape A; Mangi, Sabina; Fumakule, Robert; Di Caro, Antonino; Capobianchi, Maria R; Kitua, Andrew; Molteni, Fabrizio; Racalbuto, Vincenzo; Ippolito, Giuseppe

    2009-05-01

    The study was aimed to evaluate the malaria over/underdiagnosis and over/underprescription of antimalarial drugs. Between February and March 2007 blood samples were collected from 336 non-severe febrile outpatients attended in two peripheral Tanzanian hospitals. Microscopy and a rapid diagnostic test (RDT) were done locally and the accuracy evaluated by qualitative polymerase chain reaction (PCR) for Plasmodium spp. The testing was performed at National Institute for Infectious Diseases Lazzaro Spallanzani (INMI), Rome, Italy. As a result of PCR, we identified 26 malaria cases out of 336 (7.7%) patients. Microscopy and RDT accuracies were 93.5% and 97.6%, respectively. Overprescription and underdiagnosis rates were 29.3% and 30.8%, respectively. On-field training, clinical management of febrile illness, and malaria microscopy in remote settings should be considered.

  1. Aphasia and Cognitive Sciences: Problems of Appraisal Tests in Indian Context.

    ERIC Educational Resources Information Center

    Gupta, Santosh

    2000-01-01

    Discusses the urgency of therapeutic appraisal tests for various types of aphasia in India, where the clinical population comes from multilingual, multiethnic, and multicultural backgrounds; has a low literacy level; and hails from various geographical regions. The need for good diagnostic tests is imperative for a detailed evaluation of language…

  2. Fetal aneuploidy detection by maternal plasma DNA sequencing: a technology assessment.

    PubMed

    Walsh, Judith M E; Goldberg, James D

    2013-06-01

    The American College of Obstetricians and Gynecologists currently recommends that all pregnant women be offered screening for chromosomal abnormalities, regardless of maternal age. Traditional screening tests have detection rates ranging from 85% to 90% and false-positive rates of 3% to 5%. A woman with an abnormal noninvasive test is offered a diagnostic test, but diagnostic tests are associated with a risk of pregnancy loss. Recently, analysis of cell-free fetal DNA (cffDNA) in maternal blood has been shown to have potential for the accurate detection of some of the common fetal autosomal aneuploidies. As part of a technology assessment for the California Technology Assessment Forum, we critically reviewed the evidence for the use of cffDNA as a prenatal screening test. We evaluated the evidence for its use as either a 'primary' or an 'advanced' screening test and for its use in screening for three different trisomies: 21, 18, and 13. We evaluated whether the use of cffDNA met established technology assessment criteria and established conclusions about evidence-based use of this new technology. © 2013 John Wiley & Sons, Ltd.

  3. Comparison of rapid diagnostic tests for the detection of Plasmodium vivax malaria in South Korea.

    PubMed

    Kim, Jung-Yeon; Ji, So-Young; Goo, Youn-Kyoung; Na, Byoung-Kuk; Pyo, Hyo-Joo; Lee, Han-Na; Lee, Juyoung; Kim, Nam Hee; von Seidlein, Lorenz; Cheng, Qin; Cho, Shin-Hyung; Lee, Won-Ja

    2013-01-01

    South Korea is one of many countries with endemic Plasmodium vivax malaria. Here we report the evaluation of four rapid diagnostic tests (RDTs) for diagnosis of this disease. A total of 253 subjects were enrolled in the study. The sensitivities, specificities and agreement frequencies were estimated by comparing the four RDTs against the standard of nested-PCR and microscopic examination. The CareStart(TM) and SD Bioline had higher test sensitivities (99.4 and 98.8%, respectively) compared with the NanoSign and Asan Easy tests (93.0 and 94.7%, respectively). The CareStart(TM) and SD Bioline tests could detect P. vivax in samples with parasite densities <150/μl, which was a slightly better performance than the other two RDTs. The quantitative accuracy of the four RDTs was also estimated by comparing results with P. vivax counts from blood samples. Lower test price would result in increased use of these RDTs in the field. The results of this study contribute valuable information that will aid in the selection of a diagnostic method for the detection of malaria.

  4. Comparison of Rapid Diagnostic Tests for the Detection of Plasmodium vivax Malaria in South Korea

    PubMed Central

    Goo, Youn-Kyoung; Na, Byoung-Kuk; Pyo, Hyo-Joo; Lee, Han-Na; Lee, Juyoung; Kim, Nam Hee; von Seidlein, Lorenz; Cheng, Qin; Cho, Shin-Hyung; Lee, Won-Ja

    2013-01-01

    South Korea is one of many countries with endemic Plasmodium vivax malaria. Here we report the evaluation of four rapid diagnostic tests (RDTs) for diagnosis of this disease. A total of 253 subjects were enrolled in the study. The sensitivities, specificities and agreement frequencies were estimated by comparing the four RDTs against the standard of nested-PCR and microscopic examination. The CareStartTM and SD Bioline had higher test sensitivities (99.4 and 98.8%, respectively) compared with the NanoSign and Asan Easy tests (93.0 and 94.7%, respectively). The CareStartTM and SD Bioline tests could detect P. vivax in samples with parasite densities <150/μl, which was a slightly better performance than the other two RDTs. The quantitative accuracy of the four RDTs was also estimated by comparing results with P. vivax counts from blood samples. Lower test price would result in increased use of these RDTs in the field. The results of this study contribute valuable information that will aid in the selection of a diagnostic method for the detection of malaria. PMID:23667710

  5. A systematic review and meta-analysis of studies evaluating the performance and operational characteristics of dual point-of-care tests for HIV and syphilis.

    PubMed

    Gliddon, Harriet D; Peeling, Rosanna W; Kamb, Mary L; Toskin, Igor; Wi, Teodora E; Taylor, Melanie M

    2017-12-01

    Mother-to-child transmission (MTCT) of syphilis and HIV continue to be important yet preventable causes of perinatal and infant morbidity and mortality. To systematically review, critically appraise and perform a meta-analysis to evaluate the operational characteristics of dual rapid diagnostic tests (RDTs) for HIV/syphilis and evaluate whether they are cost effective, acceptable and easy to use. Systematic review and meta-analysis. We searched seven electronic bibliographic databases from 2012 to December 2016 with no language restrictions. Search keywords included HIV, syphilis and diagnosis. We included studies that evaluated the operational characteristics of dual HIV/syphilis RDTs. Outcomes included diagnostic test accuracy, cost effectiveness, ease of use and interpretation and acceptability. All studies were assessed against quality criteria and assessed for risk of bias. Of 1914 identified papers, 18 were included for the meta-analysis of diagnostic accuracy for HIV and syphilis. All diagnostic accuracy evaluation studies showed a very high sensitivity and specificity for HIV and a lower, yet adequate, sensitivity and specificity for syphilis, with some variation among types of test. Dual screening for HIV and syphilis was more cost effective than single rapid tests for HIV and syphilis and prevented more adverse pregnancy outcomes. Qualitative data suggested dual RDTs were highly acceptable to clients, who cited time to result, cost and the requirement of a single finger prick as important characteristics of dual RDTs. The results of this systematic review and meta-analysis can be used by policy-makers and national programme managers who are considering implementing dual RDTs for HIV and syphilis. PROSPERO 2016:CRD42016049168. © World Health Organization 2017. Licensee BMJ Publishing Group Limited. This is an open access article distributed under the terms of the Creative Commons Attribution IGO License (https://creativecommons.org/licenses/by/3.0/igo), which permits use, distribution, and reproduction for non-commercial purposes in any medium, provided the original work is properly cited. In any reproduction of this article there should not be any suggestion that WHO or this article endorse any specific organization or products. The use of the WHO logo is not permitted. This notice should be preserved along with the article’s original URL.

  6. Usefulness of an inexpensive, Paracheck test in detecting asymptomatic infectious reservoir of plasmodium falciparum during dry season in an inaccessible terrain in central India.

    PubMed

    Singh, N; Saxena, A; Sharma, V P

    2002-10-01

    The performance of a new indigenous rapid diagnostic test, Paracheck Pf was evaluated in detection of Plasmodium falciparum in asymptomatic children in remote forest villages of Mandla district, central India to determine the lower limits of sensitivity and specificity of rapid test. A finger prick blood sample was collected to prepare blood smear and for testing with the Paracheck test. The blood smears were read by an experienced technician blinded to the Paracheck results. The figures for specificity, sensitivity, accuracy and predictive values were calculated using microscopy as gold standard. The new diagnostic test had a sensitivity of 94% and a specificity of 89%. The positive and negative predictive values were 71% and 98%, respectively. The J -index was 0.83%. The rapid test was found to be very easy to perform and the result could be read reliably by field workers. The field evaluation with this new inexpensive test, ($0.65/test) indicates that it could be used as an epidemiological tool in the management of malaria particularly in areas where microscopy is not operationally feasible to attain the goal of the roll back malaria initiative.

  7. Design of a Tablet Computer App for Facilitation of a Molecular Blood Culture Test in Clinical Microbiology and Preliminary Usability Evaluation.

    PubMed

    Samson, Lasse L; Pape-Haugaard, Louise; Meltzer, Michelle C; Fuchs, Martin; Schønheyder, Henrik C; Hejlesen, Ole

    2016-03-18

    User mobility is an important aspect of the development of clinical information systems for health care professionals. Mobile phones and tablet computers have obtained widespread use by health care professionals, offering an opportunity for supporting the access to patient information through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). The objective of the study was to describe the design considerations of the MuxBCT app and the results of a preliminary usability evaluation. The MuxBCT tablet app was developed and set up for use in a clinical microbiology laboratory. A near-live simulation study was conducted in the clinical microbiology laboratory to evaluate the usability of the MuxBCT app. The study was designed to achieve a high degree of realism as participants carried out a scenario representing the context of use for the MuxBCT app. As the MuxBCT was under development, the scenario involved the use of molecular blood culture tests similar to the MuxBCT for identification of microorganisms from positive blood culture samples. The study participants were observed, and their interactions with the app were recorded. After the study, the participants were debriefed to clarify observations. Four medical laboratory technicians, for example, representative of end users of the app, participated in the clinical simulation study. Using the MuxBCT app, the study participants successfully identified and reported all microorganisms from the positive blood cultures examined. Three of the four participants reported that they found the app useful, while one study participant reported that she would prefer to make notes on paper and later enter them into the LIS. The preliminary usability evaluation results indicate that use of the MuxBCT tablet app can facilitate the workflow of the MuxBCT diagnostic test.

  8. Evaluation of the methodological quality of studies of the performance of diagnostic tests for bovine tuberculosis using QUADAS.

    PubMed

    Downs, Sara H; More, Simon J; Goodchild, Anthony V; Whelan, Adam O; Abernethy, Darrell A; Broughan, Jennifer M; Cameron, Angus; Cook, Alasdair J; Ricardo de la Rua-Domenech, R; Greiner, Matthias; Gunn, Jane; Nuñez-Garcia, Javier; Rhodes, Shelley; Rolfe, Simon; Sharp, Michael; Upton, Paul; Watson, Eamon; Welsh, Michael; Woolliams, John A; Clifton-Hadley, Richard S; Parry, Jessica E

    2018-05-01

    There has been little assessment of the methodological quality of studies measuring the performance (sensitivity and/or specificity) of diagnostic tests for animal diseases. In a systematic review, 190 studies of tests for bovine tuberculosis (bTB) in cattle (published 1934-2009) were assessed by at least one of 18 reviewers using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) checklist adapted for animal disease tests. VETQUADAS (VQ) included items measuring clarity in reporting (n = 3), internal validity (n = 9) and external validity (n = 2). A similar pattern for compliance was observed in studies of different diagnostic test types. Compliance significantly improved with year of publication for all items measuring clarity in reporting and external validity but only improved in four of the nine items measuring internal validity (p < 0.05). 107 references, of which 83 had performance data eligible for inclusion in a meta-analysis were reviewed by two reviewers. In these references, agreement between reviewers' responses was 71% for compliance, 32% for unsure and 29% for non-compliance. Mean compliance with reporting items was 2, 5.2 for internal validity and 1.5 for external validity. The index test result was described in sufficient detail in 80.1% of studies and was interpreted without knowledge of the reference standard test result in only 33.1%. Loss to follow-up was adequately explained in only 31.1% of studies. The prevalence of deficiencies observed may be due to inadequate reporting but may also reflect lack of attention to methodological issues that could bias the results of diagnostic test performance estimates. QUADAS was a useful tool for assessing and comparing the quality of studies measuring the performance of diagnostic tests but might be improved further by including explicit assessment of population sampling strategy. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  9. Physical examination tests for the diagnosis of femoroacetabular impingement. A systematic review.

    PubMed

    Pacheco-Carrillo, Aitana; Medina-Porqueres, Ivan

    2016-09-01

    Numerous clinical tests have been proposed to diagnose FAI, but little is known about their diagnostic accuracy. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of FAI. A search of the PubMed, SPORTDiscus and CINAHL databases was performed. Studies were considered eligible if they compared the results of physical examination tests to those of a reference standard. Methodological quality and internal validity assessment was performed by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. The systematic search strategy revealed 298 potential articles, five of which articles met the inclusion criteria. After assessment using the QUADAS score, four of the five articles were of high quality. Clinical tests included were Impingement sign, IROP test (Internal Rotation Over Pressure), FABER test (Flexion-Abduction-External Rotation), Stinchfield/RSRL (Resisted Straight Leg Raise) test, Scour test, Maximal squat test, and the Anterior Impingement test. IROP test, impingement sign, and FABER test showed the most sensitive values to identify FAI. The diagnostic accuracy of physical examination tests to assess FAI is limited due to its heterogenecity. There is a strong need for sound research of high methodological quality in this area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Stress myocardial perfusion imaging in the emergency department--new techniques for speed and diagnostic accuracy.

    PubMed

    Harrison, Sheri D; Harrison, Mark A; Duvall, W Lane

    2012-05-01

    Emergency room evaluations of patients presenting with chest pain continue to rise, and these evaluations which often include cardiac imaging, are an increasing area of resource utilization in the current health system. Myocardial perfusion imaging from the emergency department remains a vital component of the diagnosis or exclusion of coronary artery disease as the etiology of chest pain. Recent advances in camera technology, and changes to the imaging protocols have allowed MPI to become a more efficient way of providing this diagnostic information. Compared with conventional SPECT, new high-efficiency CZT cameras provide a 3-5 fold increase in photon sensitivity, 1.65-fold improvement in energy resolution and a 1.7-2.5-fold increase in spatial resolution. With stress-only imaging, rest images are eliminated if stress images are normal, as they provide no additional prognostic or diagnostic value and cancelling the rest images would shorten the length of the test which is of particular importance to the ED population. The rapid but accurate triage of patients in an ED CPU is essential to their care, and stress-only imaging and new CZT cameras allow for shorter test time, lower radiation doses and lower costs while demonstrating good clinical outcomes. These changes to nuclear stress testing can allow for faster throughput of patients through the emergency department while providing a safe and efficient evaluation of chest pain.

  11. Malaria rapid diagnostic test in children: The Zamfara, Nigeria experience.

    PubMed

    Abdulkadir, Isa; Rufai, Hafsah Ahmad; Ochapa, Sunday Onazi; Malam, Mado Sani; Garba, Bilkisu Ilah; Oloko, Adebayo Ganiyu Yusuf; George, Idemudia Itoya

    2015-01-01

    Malaria remains a major cause of under-five morbidity and mortality in Nigeria, and prompt diagnosis occupies a strategic position in its management. Malaria rapid diagnostic test (RDT), a nontechnical, easy to perform test promises to meet this need. It is important to locally document the usefulness of the use of RDT in making prompt malaria diagnosis in children. To determine the prevalence of malaria and evaluate the diagnostic performance of malaria RDT kit in febrile under-five children presenting to a Tertiary Health Facility in Gusau, North-Western Nigeria. A cross-sectional study of children aged 6-59 months, evaluated for malaria in a tertiary health facility from August 2012 to January 2013. Information was obtained from care providers of all subjects with fever and a presumptive diagnosis of malaria. All subjects were investigated using Giemsa stain microscopy and Carestart™ malaria RDT. The prevalence of malaria in 250 febrile under-five children was 54%. Three-quarter (79%) of the children received inappropriate nonrecommended antimalaria prior to their presentation, including 20% who received chloroquine. The overall sensitivity of RDT was 40.3%. The specificity, positive and negative predictive values were 89.6%, 81.8%, and 56.5%, respectively. Use of RDT should be encouraged for screening and diagnosis using a protocol such that febrile children with positive RDT results are confirmed as having malaria while those with negative results are further evaluated using microscopy.

  12. Molecular Methods and Platforms for Infectious Diseases Testing

    PubMed Central

    Emmadi, Rajyasree; Boonyaratanakornkit, Jerry B.; Selvarangan, Rangaraj; Shyamala, Venkatakrishna; Zimmer, Barbara L.; Williams, Laurina; Bryant, Bonita; Schutzbank, Ted; Schoonmaker, Michele M.; Amos Wilson, Jean A.; Hall, Leslie; Pancholi, Preeti; Bernard, Kathryn

    2011-01-01

    The superior sensitivity and specificity associated with the use of molecular assays has greatly improved the field of infectious disease diagnostics by providing clinicians with results that are both accurate and rapidly obtained. Herein, we review molecularly based infectious disease diagnostic tests that are Food and Drug Administration approved or cleared and commercially available in the United States as of December 31, 2010. We describe specific assays and their performance, as stated in the Food and Drug Administration's Summary of Safety and Effectiveness Data or the Office of In Vitro Diagnostic Device Evaluation and Safety's decision summaries, product inserts, or peer-reviewed literature. We summarize indications for testing, limitations, and challenges related to implementation in a clinical laboratory setting for a wide variety of common pathogens. The information presented in this review will be particularly useful for laboratories that plan to implement or expand their molecular offerings in the near term. PMID:21871973

  13. Atomic Resonance Radiation Energetics Investigation as a Diagnostic Method for Non-Equilibrium Hypervelocity Flows

    NASA Technical Reports Server (NTRS)

    Meyer, Scott A.; Bershader, Daniel; Sharma, Surendra P.; Deiwert, George S.

    1996-01-01

    Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.

  14. Fasting Triglycerides and Glucose Index as a Diagnostic Test for Insulin Resistance in Young Adults.

    PubMed

    Guerrero-Romero, Fernando; Villalobos-Molina, Rafael; Jiménez-Flores, J Rafael; Simental-Mendia, Luis E; Méndez-Cruz, René; Murguía-Romero, Miguel; Rodríguez-Morán, Martha

    2016-07-01

    Although the Glucose and Triglyceride levels (TyG) index is useful for identification of insulin resistance (IR) in different ethnic groups, it has not been evaluated in young adults. We undertook this study to evaluate the TyG index as a diagnostic test for IR in young adults. A total of 5,538 healthy young adults, 3,795 (68.5%) non-pregnant women and 1,743 (31.5%) men, with an average age of 19.2 ± 1.4 years, were enrolled in a population-based cross-sectional study. To estimate diagnostic characteristics of the TyG index, a randomized subsample of the target population (n = 75) was under euglycemic-hyperinsulinemic clamp test. Using the cutoff values obtained in the clamp study, the diagnostic concordance between TyG index and HOMA-IR was evaluated in the overall population. The TyG index was calculated as the Ln[fasting triglycerides (mg/dL) × fasting glucose (mg/dL)]/2. Normal weight, overweight, and obesity were identified in 3,632 (65.6%), 1,355 (24.5%), and 551 (9.9%) participants. A total of 346 (9.1%) men and 278 (15.9%) women exhibited IR. The best cutoff value of TyG index for diagnosis of IR was 4.55 (sensitivity 0.687, negative predictive value (NPV) 0.844, and negative likelihood ratio (NLR) 0.47) for women and 4.68 (sensitivity 0.673, NPV 0.900, and NLR 0.45) for men. In normal-weight individuals the diagnostic concordance between TyG index and HOMA-IR was 0.934 and 0.915, in the overweight subjects was 0.908 and 0.895 and, in the obese participants 0.916 and 0.950, for men and women, respectively. TyG index may be useful for screening IR in young adults. Copyright © 2016 IMSS. Published by Elsevier Inc. All rights reserved.

  15. Evaluation of a rapid diagnostic field test kit for identification of Phytophthora ramorum, P. kernoviae and other Phytophthora species at the point of inspection

    Treesearch

    C.R. Lane; E. Hobden; L. Laurenson; V.C. Barton; K.J.D. Hughes; H. Swan; N. Boonham; A.J. Inman

    2008-01-01

    Plant health regulations to prevent the introduction and spread of Phytophthora ramorum and P. kernoviae require rapid, cost effective diagnostic methods for screening large numbers of plant samples at the time of inspection. Current on-site techniques require expensive equipment, considerable expertise and are not suited for plant...

  16. What Is behind the Diagnosis of Learning Disability in Austrian Schools? An Empirical Evaluation of the Results of the Diagnostic Process

    ERIC Educational Resources Information Center

    Gebhardt, Markus; Krammer, Mathias; Schwab, Susanne; Rossmann, Peter; Klicpera, Barbara Gasteiger; Klatten, Susanne

    2013-01-01

    Every school system has to deal with children with Learning Disabilities (LD). However, the concepts of LD, the assessment procedures, the diagnostic criteria as well as their interpretation vary widely from country to country. What they usually seem to have in common is that general cognitive abilities, as measured by standardized IQ tests, are…

  17. What Is behind the Diagnosis of Learning Disability in Austrian Schools? An Empirical Evaluation of the Results of the Diagnostic Process

    ERIC Educational Resources Information Center

    Gebhardt, Markus; Krammer, Mathias; Schwab, Susanne; Rossmann, Peter; Gasteiger Klicpera, Barbara

    2013-01-01

    Every school system has to deal with children with Learning Disabilities (LD). However, the concepts of LD, the assessment procedures, the diagnostic criteria as well as their interpretation vary widely from country to country. What they usually have in common is that general cognitive abilities, as measured by standardized IQ tests, are seen as…

  18. Diagnostic performance characteristics of a rapid field test for anthrax in cattle.

    PubMed

    Muller, Janine; Gwozdz, Jacek; Hodgeman, Rachel; Ainsworth, Catherine; Kluver, Patrick; Czarnecki, Jill; Warner, Simone; Fegan, Mark

    2015-07-01

    Although diagnosis of anthrax can be made in the field with a peripheral blood smear, and in the laboratory with bacterial culture or molecular based tests, these tests require either considerable experience or specialised equipment. Here we report on the evaluation of the diagnostic sensitivity and specificity of a simple and rapid in-field diagnostic test for anthrax, the anthrax immunochromatographic test (AICT). The AICT detects the protective antigen (PA) component of the anthrax toxin present within the blood of an animal that has died from anthrax. The test provides a result in 15min and offers the advantage of avoiding the necessity for on-site necropsy and subsequent occupational risks and environmental contamination. The specificity of the test was determined by testing samples taken from 622 animals, not infected with Bacillus anthracis. Diagnostic sensitivity was estimated on samples taken from 58 animals, naturally infected with B. anthracis collected over a 10-year period. All samples used to estimate the diagnostic sensitivity and specificity of the AICT were also tested using the gold standard of bacterial culture. The diagnostic specificity of the test was estimated to be 100% (99.4-100%; 95% CI) and the diagnostic sensitivity was estimated to be 93.1% (83.3-98.1%; 95% CI) (Clopper-Pearson method). Four samples produced false negative AICT results. These were among 9 samples, all of which tested positive for B. anthracis by culture, where there was a time delay between collection and testing of >48h and/or the samples were collected from animals that were >48h post-mortem. A statistically significant difference (P<0.001; Fishers exact test) was found between the ability of the AICT to detect PA in samples from culture positive animals <48h post-mortem, 49 of 49, Se=100% (92.8-100%; 95% CI) compared with samples tested >48h post-mortem 5 of 9 Se=56% (21-86.3%; 95% CI) (Clopper-Pearson method). Based upon these results a post hoc cut-off for use of the AICT of 48h post-mortem was applied, Se=100% (92.8-100%; 95% CI) and Sp=100% (99.4-100%; 95% CI). The high diagnostic sensitivity and specificity and the simplicity of the AICT enables it to be used for active surveillance in areas with a history of anthrax, or used as a preliminary tool in investigating sudden, unexplained death in cattle. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Medically Underserved Girls Receive Less Evaluation for Short Stature

    PubMed Central

    Feemster, Kristen A.; Pati, Susmita; Ramos, Mark; Grundmeier, Robert; Cucchiara, Andrew J.; Stallings, Virginia A.

    2011-01-01

    OBJECTIVE: To determine if gender is associated with diagnostic evaluation by primary care pediatricians caring for children with growth-faltering. PATIENTS AND METHODS: This was a retrospective study of children who were attending 4 urban pediatric primary care practices affiliated with a tertiary pediatric hospital. Growth-faltering was defined as height at the <5th percentile or a z-score decrease of ≥1.5 SDs before 18 months of age or ≥1 SD thereafter. For each child, height z score, age, gender, race, insurance, diagnostic tests, and subspecialist appointments were examined. RESULTS: Of 33 476 children, 3007 had growth-faltering (mean height: −1.5 ± 1.0 vs 0.3 ± 0.9 SDs in those without growth-faltering). Boys comprised 53% of the growth-faltering group (vs 51% of the nonfaltering group; P < .01). Among children with growth-faltering, 2.8% had endocrinology appointments (vs 0.8% of others; P < .0001) and 6% had gastroenterology appointments (vs 1.5% of others; P < .0001). Subspecialty care was not associated with gender. Pediatricians ordered diagnostic tests for a significantly greater proportion of children with growth-faltering than others. In multivariate analysis of height z score among children with growth-faltering, tests for chromosomes (1.4% of short girls vs 0.4% of short boys; P < .005) and growth hormone/insulin-like growth factor axis (0.9% of short girls vs 1.8% of short boys; P < .05) were associated with gender. Thirty-five percent of the girls for whom chromosome testing was performed were 12 years old or older. CONCLUSIONS: Patterns in diagnostic testing of children with growth-faltering by their pediatricians may lead to underdiagnosis of Turner syndrome and growth hormone deficiency among girls. PMID:21422085

  20. Celiac Disease: Diagnostic Standards and Dilemmas

    PubMed Central

    Kaswala, Dharmesh H.; Veeraraghavan, Gopal; Kelly, Ciaran P.; Leffler, Daniel A.

    2015-01-01

    Celiac Disease (CD) affects at least 1% of the population and evidence suggests that prevalence is increasing. The diagnosis of CD depends on providers being alert to both typical and atypical presentations and those situations in which patients are at high risk for the disease. Because of variable presentation, physicians need to have a low threshold for celiac testing. Robust knowledge of the pathogenesis of this autoimmune disease has served as a catalyst for the development of novel diagnostic tools. Highly sensitive and specific serological assays including Endomysial Antibody (EMA), tissue transglutaminase (tTG), and Deamidated Gliadin Peptide (DGP) have greatly simplified testing for CD and serve as the foundation for celiac diagnosis. In addition, genetic testing for HLA DQ2 and DQ8 has become more widely available and there has been refinement of the gluten challenge for use in diagnostic algorithms. While diagnosis is usually straightforward, in special conditions including IgA deficiency, very young children, discrepant histology and serology, and adoption of a gluten free diet prior to testing, CD can be difficult to diagnose. In this review, we provide an overview of the history and current state of celiac disease diagnosis and provide guidance for evaluation of CD in difficult diagnostic circumstances. PMID:28943611

  1. Molecular and Nonmolecular Diagnostic Methods for Invasive Fungal Infections

    PubMed Central

    Arvanitis, Marios; Anagnostou, Theodora; Fuchs, Beth Burgwyn; Caliendo, Angela M.

    2014-01-01

    SUMMARY Invasive fungal infections constitute a serious threat to an ever-growing population of immunocompromised individuals and other individuals at risk. Traditional diagnostic methods, such as histopathology and culture, which are still considered the gold standards, have low sensitivity, which underscores the need for the development of new means of detecting fungal infectious agents. Indeed, novel serologic and molecular techniques have been developed and are currently under clinical evaluation. Tests like the galactomannan antigen test for aspergillosis and the β-glucan test for invasive Candida spp. and molds, as well as other antigen and antibody tests, for Cryptococcus spp., Pneumocystis spp., and dimorphic fungi, have already been established as important diagnostic approaches and are implemented in routine clinical practice. On the other hand, PCR and other molecular approaches, such as matrix-assisted laser desorption ionization (MALDI) and fluorescence in situ hybridization (FISH), have proved promising in clinical trials but still need to undergo standardization before their clinical use can become widespread. The purpose of this review is to highlight the different diagnostic approaches that are currently utilized or under development for invasive fungal infections and to identify their performance characteristics and the challenges associated with their use. PMID:24982319

  2. Evaluation of the Clearview® malaria pLDH malaria rapid diagnostic test in a non-endemic setting

    PubMed Central

    2011-01-01

    Background Malaria Rapid Diagnostic Tests (RDTs) are widely used to diagnose malaria. The present study evaluated a new RDT, the Clearview® Malaria pLDH test targeting the pan-Plasmodium antigen lactate dehydrogenase (pLDH). Methods The Clearview® Malaria pLDH test was evaluated on fresh samples obtained in returned international travellers using microscopy corrected by PCR as the reference method. Included samples were Plasmodium falciparum (139), Plasmodium vivax (22), Plasmodium ovale (20), Plasmodium malariae (7), and 102 negative. Results Overall sensitivity for the detection of Plasmodium spp was 93.2%. For P. falciparum, the sensitivity was 98.6%; for P. vivax, P. ovale and P. malariae, overall sensitivities were 90.9%, 60.0% and 85.7% respectively. For P. falciparum and for P. vivax, the sensitivities increased to 100% at parasite densities above 100/μl. The specificity was 100%. The test was easily to perform and the result was stable for at least 1 hour. Conclusion The Clearview® Malaria pLDH was efficient for the diagnosis of malaria. The test was very sensitive for P. falciparum and P. vivax detection. The sensitivities for P. ovale and P. malariae were better than other RDTs PMID:21951996

  3. A novel metric that quantifies risk stratification for evaluating diagnostic tests: The example of evaluating cervical-cancer screening tests across populations.

    PubMed

    Katki, Hormuzd A; Schiffman, Mark

    2018-05-01

    Our work involves assessing whether new biomarkers might be useful for cervical-cancer screening across populations with different disease prevalences and biomarker distributions. When comparing across populations, we show that standard diagnostic accuracy statistics (predictive values, risk-differences, Youden's index and Area Under the Curve (AUC)) can easily be misinterpreted. We introduce an intuitively simple statistic for a 2 × 2 table, Mean Risk Stratification (MRS): the average change in risk (pre-test vs. post-test) revealed for tested individuals. High MRS implies better risk separation achieved by testing. MRS has 3 key advantages for comparing test performance across populations with different disease prevalences and biomarker distributions. First, MRS demonstrates that conventional predictive values and the risk-difference do not measure risk-stratification because they do not account for test-positivity rates. Second, Youden's index and AUC measure only multiplicative relative gains in risk-stratification: AUC = 0.6 achieves only 20% of maximum risk-stratification (AUC = 0.9 achieves 80%). Third, large relative gains in risk-stratification might not imply large absolute gains if disease is rare, demonstrating a "high-bar" to justify population-based screening for rare diseases such as cancer. We illustrate MRS by our experience comparing the performance of cervical-cancer screening tests in China vs. the USA. The test with the worst AUC = 0.72 in China (visual inspection with acetic acid) provides twice the risk-stratification (i.e. MRS) of the test with best AUC = 0.83 in the USA (human papillomavirus and Pap cotesting) because China has three times more cervical precancer/cancer. MRS could be routinely calculated to better understand the clinical/public-health implications of standard diagnostic accuracy statistics. Published by Elsevier Inc.

  4. Optimizing Patient-centered Communication and Multidisciplinary Care Coordination in Emergency Diagnostic Imaging: A Research Agenda.

    PubMed

    Sabbatini, Amber K; Merck, Lisa H; Froemming, Adam T; Vaughan, William; Brown, Michael D; Hess, Erik P; Applegate, Kimberly E; Comfere, Nneka I

    2015-12-01

    Patient-centered emergency diagnostic imaging relies on efficient communication and multispecialty care coordination to ensure optimal imaging utilization. The construct of the emergency diagnostic imaging care coordination cycle with three main phases (pretest, test, and posttest) provides a useful framework to evaluate care coordination in patient-centered emergency diagnostic imaging. This article summarizes findings reached during the patient-centered outcomes session of the 2015 Academic Emergency Medicine consensus conference "Diagnostic Imaging in the Emergency Department: A Research Agenda to Optimize Utilization." The primary objective was to develop a research agenda focused on 1) defining component parts of the emergency diagnostic imaging care coordination process, 2) identifying gaps in communication that affect emergency diagnostic imaging, and 3) defining optimal methods of communication and multidisciplinary care coordination that ensure patient-centered emergency diagnostic imaging. Prioritized research questions provided the framework to define a research agenda for multidisciplinary care coordination in emergency diagnostic imaging. © 2015 by the Society for Academic Emergency Medicine.

  5. Evaluation of the indirect fluorescent antibody test as a diagnostic tool for East Coast fever in eastern Zambia.

    PubMed

    Billiouw, M; Brandt, J; Vercruysse, J; Speybroeck, N; Marcotty, T; Mulumba, M; Berkvens, D

    2005-02-28

    Serological surveys using the schizont indirect fluorescence antibody test (IFAt) are routinely carried out to monitor the Theileria parva infection prevalence. The present study evaluates the diagnostic accuracy of the IFAt in eastern Zambia, where the transmission of T. parva is highly seasonal. The data set resulted from a sentinel herd (n = 105 animals) study carried out between 1995 and 2000 and was split into an epidemic period, during which the majority of the cattle became infected, and an endemic period with seasonal disease incidence in calves. In the epidemic period the T. parva seroprevalence followed closely the build up of the herd immunity. In the endemic period the seroprevalence fluctuates considerably although most of the animals had been infected. Overall, the diagnostic sensitivity of the IFA test was 55% at cut-off titre 1:40 and 28% at cut-off 1:160. The specificity of the test was 86 and 95%, respectively. A logistic regression model demonstrates that the sensitivity is significantly lower when the T. parva transmission is low (p < 0.01). The analysis of receiver operator characteristic curves classifies the test as moderately accurate (area under the curve, AUC = 0.79) during the epidemic period and less accurate in the endemic period (AUC = 0.63). Neonatal serology surveys yield a better estimate of the infection prevalence. The sensitivity of the neonatal test was 73% at cut-off titre 1:40 and 24% at cut-off 1:160.

  6. Evaluation of a rapid IgM detection test for diagnosis of acute leptospirosis in dogs.

    PubMed

    Lizer, J; Grahlmann, M; Hapke, H; Velineni, S; Lin, D; Kohn, B

    2017-05-27

    Recently, a lateral flow assay (LFA) for detection of Leptospira -specific IgM in canine sera became commercially available in Europe. The present study aims to evaluate the diagnostic performance of this assay using canine sera from a collection of diagnostic accessions. Diagnostic sensitivity was assessed by testing 37 acute-phase and 9 corresponding convalescent-phase sera from dogs with a confirmed diagnosis of leptospirosis. Specificity was determined by testing sera from sick dogs with non-leptospiral infections (n=15) and healthy dogs with incomplete history of vaccination (n=45). During acute phase of illness, LFA scored positive for 28/37 sera with a sensitivity of 75.7 per cent while only 9/37 (24.3 per cent) samples were positive on microscopic agglutination test. The specificity of the LFA was 98.3 per cent (59/60). This test showed 89.7 and 100 per cent overall agreements with clinical diagnosis for acute-phase and convalescent-phase sera, respectively. The impact of vaccination on the LFA was also determined and vaccine-stimulated IgM responses were negative in 19/25 (76 per cent) dogs at 12 weeks post vaccination. In conclusion, the LFA is a rapid and reliable test for early detection of Leptospira -specific IgM during acute phase of canine leptospirosis. However, interpretation of a positive result must be made in the context of clinical signs and vaccination history. British Veterinary Association.

  7. [Evaluation (assessment) of three tests for diagnosis of geohelmints in Colombia].

    PubMed

    López, Myriam Consuelo; Moncada, Ligia Inés; Ariza-Araújo, Yoseth; Fernández-Niño, Julián Alfredo; Reyes, Patricia; Nicholls, Rubén Santiago

    2013-01-01

    Soil-transmitted helminth infections are considered a public health problem in developing countries. The diagnostic tests, both for individual parient diagnosis as for population studies should be evaluated in terms of validity and reliability. To compare the direct examination, the modified Ritchie-Frick method, a Kato-Katz designed by a Brazilian group and one designed by the WHO, for the diagnosis of soil-transmitted helminthes. A diagnostic test reliability study was performed. The same stool sample was analyzed by the same observer using four diagnostic tests. 204 samples were obtained, 194 of those fulfilled the inclusion criteria and were analyzed. The observers did not know the participants' identity neither the other tests results. For the analysis the Kato-Katz (WHO) was considered as the gold standard. For the reliability assessment percent agreement, positive percent agreement, Kappa statistic, and intraclass correlation were performed. The Brazilian Kato-Katz showed a good performance with high sensitivity and specificity for T. trichiura and Hookworm with values of 0.97 and 0.96 respectively, and a high specificity with mild sensitivity for A. lumbricoides (0.95 and 0.79) meanwhile the direct examination and the Ritche-Frick method showed a performance between mild and poor. The differences were higher for hookworm and Trichiuris trichiura than for Ascaris lumbricoides. The Brazilian Kato Katz test could be implemented, but further studies are needed to correlate its operative capacity with its feasibility, availability and cost.

  8. Test-treatment RCTs are susceptible to bias: a review of the methodological quality of randomized trials that evaluate diagnostic tests.

    PubMed

    Ferrante di Ruffano, Lavinia; Dinnes, Jacqueline; Sitch, Alice J; Hyde, Chris; Deeks, Jonathan J

    2017-02-24

    There is a growing recognition for the need to expand our evidence base for the clinical effectiveness of diagnostic tests. Many international bodies are calling for diagnostic randomized controlled trials to provide the most rigorous evidence of impact to patient health. Although these so-called test-treatment RCTs are very challenging to undertake due to their methodological complexity, they have not been subjected to a systematic appraisal of their methodological quality. The extent to which these trials may be producing biased results therefore remains unknown. We set out to address this issue by conducting a methodological review of published test-treatment trials to determine how often they implement adequate methods to limit bias and safeguard the validity of results. We ascertained all test-treatment RCTs published 2004-2007, indexed in CENTRAL, including RCTs which randomized patients to diagnostic tests and measured patient outcomes after treatment. Tests used for screening, monitoring or prognosis were excluded. We assessed adequacy of sequence generation, allocation concealment and intention-to-treat, appropriateness of primary analyses, blinding and reporting of power calculations, and extracted study characteristics including the primary outcome. One hundred three trials compared 105 control with 119 experimental interventions, and reported 150 primary outcomes. Randomization and allocation concealment were adequate in 57 and 37% of trials. Blinding was uncommon (patients 5%, clinicians 4%, outcome assessors 21%), as was an adequate intention-to-treat analysis (29%). Overall 101 of 103 trials (98%) were at risk of bias, as judged using standard Cochrane criteria. Test-treatment trials are particularly susceptible to attrition and inadequate primary analyses, lack of blinding and under-powering. These weaknesses pose much greater methodological and practical challenges to conducting reliable RCT evaluations of test-treatment strategies than standard treatment interventions. We suggest a cautious approach that first examines whether a test-treatment intervention can accommodate the methodological safeguards necessary to minimize bias, and highlight that test-treatment RCTs require different methods to ensure reliability than standard treatment trials. Please see the companion paper to this article: http://bmcmedresmethodol.biomedcentral.com/articles/10.1186/s12874-016-0286-0 .

  9. MPT64 antigen detection test improves routine diagnosis of extrapulmonary tuberculosis in a low-resource setting: A study from the tertiary care hospital in Zanzibar.

    PubMed

    Jørstad, Melissa Davidsen; Marijani, Msafiri; Dyrhol-Riise, Anne Ma; Sviland, Lisbet; Mustafa, Tehmina

    2018-01-01

    Extrapulmonary tuberculosis (EPTB) is a diagnostic challenge. An immunochemistry-based MPT64 antigen detection test (MPT64 test) has reported higher sensitivity in the diagnosis of EPTB compared with conventional methods. The objective of this study was to implement and evaluate the MPT64 test in routine diagnostics in a low-resource setting. Patients with presumptive EPTB were prospectively enrolled at Mnazi Mmoja Hospital, Zanzibar, and followed to the end of treatment. Specimens collected were subjected to routine diagnostics, GeneXpert® MTB/RIF assay and the MPT64 test. The performance of the MPT64 test was assessed using a composite reference standard, defining the patients as tuberculosis (TB) cases or non-TB cases. Patients (n = 132) were classified as confirmed TB (n = 12), probable TB (n = 34), possible TB (n = 18), non-TB (n = 62) and uncategorized (n = 6) cases. Overall, in comparison to the composite reference standard for diagnosis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the MPT64 test was 69%, 95%, 94%, 75% and 82%, respectively. The MPT64 test performance was best in TB lymphadenitis cases (n = 67, sensitivity 79%, specificity 97%) and in paediatric TB (n = 41, sensitivity 100%, specificity 96%). We show that the MPT64 test can be implemented in routine diagnostics in a low-resource setting and improves the diagnosis of EPTB, especially in TB lymphadenitis and in children.

  10. Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

    PubMed

    Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C

    2007-01-01

    After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.

  11. [Evaluation of the toxoplasmosis seroprevalence in pregnant women and creating a diagnostic algorithm].

    PubMed

    Mumcuoglu, Ipek; Toyran, Alparslan; Cetin, Feyza; Coskun, Feride Alaca; Baran, Irmak; Aksu, Neriman; Aksoy, Altan

    2014-04-01

    Toxoplasma gondii, an obligatory intracellular protozoon is widely distributed around the world and can infect all mammals and birds. While acquired toxoplasmosis is usually asymptomatic in healthy subjects, acute infection during pregnancy may lead to abortion, stillbirth, fetal neurological and ocular damages. For the prevention of congenital toxoplasmosis it is recommended that a screening programme and a diagnostic algorithm in pregnant women should be implemented while considering the cost effectiveness. Thus, it is necessary to determine the seroprevalence of toxoplasmosis in pregnant women and the actual risk of T.gondii transmission during pregnancy in a certain area. The aims of this study were to detect the T.gondii seropositivity in the pregnant women admitted to our hospital and to create a diagnostic algorithm in order to solve the problems arising from interpretation of the serological test results. A total of 6140 women aged 15-49 years who were admitted to our hospital between April 1st, 2010 to July 31st, 2013, were evaluated retrospectively. In the serum samples, T.gondii IgM, IgG and IgG avidity tests were performed by VIDAS automated analyzer using TOXO IgM, TOXO IgG II and TOXO IgG avidity kits (bioMerieux, France). It was noted that, both T.gondii IgM and IgG tests were requested from 4758 (77.5%) of the pregnant women, while only IgM test from 1382 (22.5%) cases. Sole IgM positivity was found as 0.2% (11/6140), IgG as 26.4% (1278/4758) and both IgM + IgG as 0.9% (44/4758). T.gondii IgG avidity tests were requested from 12 of 44 women who were found both IgM and IgG positive and eight of them revealed high avidity and four low avidity. Avidity test was ordered for the 91 (7.1%) of 1278 sole IgG positive cases and four of them were found to have low avidity. IgG avidity test was ordered for 554 (16.2%) of IgM and/or IgG negative subjects, however, the test was not performed according to rejection criteria of the laboratory. It was noticed that no re-testing was requested for none of the seronegative cases (3428/4758; 72%) during their follow-up. In our study, total Toxoplasma seropositivity rate among pregnant women was detected as 28% (1330/4758), showing statistically significant increase (p< 0.05) with age. There was no significant difference (p> 0.05) in the seropositivity rate between the years (2010-2013). Following the evaluation of the test orders, the problems related to test orders and interpretation of the test results were determined and a diagnostic algorithm to be used in our hospital, was established to minimize such problems in toxoplasma serology. It was concluded that a diagnostic algorithm related to toxoplasmosis serology should be implemented for the appropriate evaluation of the risk of acute toxoplasmosis during pregnancy. Such an approach is necessary to support the clinical diagnosis and to minimize the anxiety in pregnant women about congenital toxoplasmosis.

  12. Meta-analysis of diagnostic test data: a bivariate Bayesian modeling approach.

    PubMed

    Verde, Pablo E

    2010-12-30

    In the last decades, the amount of published results on clinical diagnostic tests has expanded very rapidly. The counterpart to this development has been the formal evaluation and synthesis of diagnostic results. However, published results present substantial heterogeneity and they can be regarded as so far removed from the classical domain of meta-analysis, that they can provide a rather severe test of classical statistical methods. Recently, bivariate random effects meta-analytic methods, which model the pairs of sensitivities and specificities, have been presented from the classical point of view. In this work a bivariate Bayesian modeling approach is presented. This approach substantially extends the scope of classical bivariate methods by allowing the structural distribution of the random effects to depend on multiple sources of variability. Meta-analysis is summarized by the predictive posterior distributions for sensitivity and specificity. This new approach allows, also, to perform substantial model checking, model diagnostic and model selection. Statistical computations are implemented in the public domain statistical software (WinBUGS and R) and illustrated with real data examples. Copyright © 2010 John Wiley & Sons, Ltd.

  13. Adjusting for partial verification or workup bias in meta-analyses of diagnostic accuracy studies.

    PubMed

    de Groot, Joris A H; Dendukuri, Nandini; Janssen, Kristel J M; Reitsma, Johannes B; Brophy, James; Joseph, Lawrence; Bossuyt, Patrick M M; Moons, Karel G M

    2012-04-15

    A key requirement in the design of diagnostic accuracy studies is that all study participants receive both the test under evaluation and the reference standard test. For a variety of practical and ethical reasons, sometimes only a proportion of patients receive the reference standard, which can bias the accuracy estimates. Numerous methods have been described for correcting this partial verification bias or workup bias in individual studies. In this article, the authors describe a Bayesian method for obtaining adjusted results from a diagnostic meta-analysis when partial verification or workup bias is present in a subset of the primary studies. The method corrects for verification bias without having to exclude primary studies with verification bias, thus preserving the main advantages of a meta-analysis: increased precision and better generalizability. The results of this method are compared with the existing methods for dealing with verification bias in diagnostic meta-analyses. For illustration, the authors use empirical data from a systematic review of studies of the accuracy of the immunohistochemistry test for diagnosis of human epidermal growth factor receptor 2 status in breast cancer patients.

  14. Systematic review of patient history and physical examination to diagnose chronic low back pain originating from the facet joints.

    PubMed

    Maas, E T; Juch, J N S; Ostelo, R W J G; Groeneweg, J G; Kallewaard, J W; Koes, B W; Verhagen, A P; Huygen, F J P M; van Tulder, M W

    2017-03-01

    Patient history and physical examination are frequently used procedures to diagnose chronic low back pain (CLBP) originating from the facet joints, although the diagnostic accuracy is controversial. The aim of this systematic review is to determine the diagnostic accuracy of patient history and/or physical examination to identify CLBP originating from the facet joints using diagnostic blocks as reference standard. We searched MEDLINE, EMBASE, CINAHL, Web of Science and the Cochrane Collaboration database from inception until June 2016. Two review authors independently selected studies for inclusion, extracted data and assessed the risk of bias. We calculated sensitivity and specificity values, with 95% confidence intervals (95% CI). Twelve studies were included, in which 129 combinations of index tests and reference standards were presented. Most of these index tests have only been evaluated in single studies with a high risk of bias. Four studies evaluated the diagnostic accuracy of the Revel's criteria combination. Because of the clinical heterogeneity, results were not pooled. The published sensitivities ranged from 0.11 (95% CI 0.02-0.29) to 1.00 (95% CI 0.75-1.00), and the specificities ranged from 0.66 (95% CI 0.46-0.82) to 0.91 (95% CI 0.83-0.96). Due to clinical heterogeneity, the evidence for the diagnostic accuracy of patient history and/or physical examination to identify facet joint pain is inconclusive. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. Patient history and physical examination cannot be used to limit the need of a diagnostic block. The validity of the diagnostic facet joint block should be studied, and high quality studies are required to confirm the results of single studies. © 2016 European Pain Federation - EFIC®.

  15. Evidence-Based Toxicology.

    PubMed

    Hoffmann, Sebastian; Hartung, Thomas; Stephens, Martin

    Evidence-based toxicology (EBT) was introduced independently by two groups in 2005, in the context of toxicological risk assessment and causation as well as based on parallels between the evaluation of test methods in toxicology and evidence-based assessment of diagnostics tests in medicine. The role model of evidence-based medicine (EBM) motivated both proposals and guided the evolution of EBT, whereas especially systematic reviews and evidence quality assessment attract considerable attention in toxicology.Regarding test assessment, in the search of solutions for various problems related to validation, such as the imperfectness of the reference standard or the challenge to comprehensively evaluate tests, the field of Diagnostic Test Assessment (DTA) was identified as a potential resource. DTA being an EBM discipline, test method assessment/validation therefore became one of the main drivers spurring the development of EBT.In the context of pathway-based toxicology, EBT approaches, given their objectivity, transparency and consistency, have been proposed to be used for carrying out a (retrospective) mechanistic validation.In summary, implementation of more evidence-based approaches may provide the tools necessary to adapt the assessment/validation of toxicological test methods and testing strategies to face the challenges of toxicology in the twenty first century.

  16. Combined diagnostic performance of coronary computed tomography angiography and computed tomography derived fractional flow reserve for the evaluation of myocardial ischemia: A meta-analysis.

    PubMed

    Tan, Xiao Wei; Zheng, Qishi; Shi, Luming; Gao, Fei; Allen, John Carson; Coenen, Adriaan; Baumann, Stefan; Schoepf, U Joseph; Kassab, Ghassan S; Lim, Soo Teik; Wong, Aaron Sung Lung; Tan, Jack Wei Chieh; Yeo, Khung Keong; Chin, Chee Tang; Ho, Kay Woon; Tan, Swee Yaw; Chua, Terrance Siang Jin; Chan, Edwin Shih Yen; Tan, Ru San; Zhong, Liang

    2017-06-01

    To evaluate the combined diagnostic accuracy of coronary computed tomography angiography (CCTA) and computed tomography derived fractional flow reserve (FFRct) in patients with suspected or known coronary artery disease (CAD). PubMed, The Cochrane library, Embase and OpenGray were searched to identify studies comparing diagnostic accuracy of CCTA and FFRct. Diagnostic test measurements of FFRct were either extracted directly from the published papers or calculated from provided information. Bivariate models were conducted to synthesize the diagnostic performance of combined CCTA and FFRct at both "per-vessel" and "per-patient" levels. 7 articles were included for analysis. The combined diagnostic outcomes from "both positive" strategy, i.e. a subject was considered as "positive" only when both CCTA and FFRct were "positive", demonstrated relative high specificity (per-vessel: 0.91; per-patient: 0.81), high positive likelihood ratio (LR+, per-vessel: 7.93; per-patient: 4.26), high negative likelihood ratio (LR-, per-vessel: 0.30; per patient: 0.24) and high accuracy (per-vessel: 0.91; per-patient: 0.81) while "either positive" strategy, i.e. a subject was considered as "positive" when either CCTA or FFRct was "positive", demonstrated relative high sensitivity (per-vessel: 0.97; per-patient: 0.98), low LR+ (per-vessel: 1.50; per-patient: 1.17), low LR- (per-vessel: 0.07; per-patient: 0.09) and low accuracy (per-vessel: 0.57; per-patient: 0.54). "Both positive" strategy showed better diagnostic performance to rule in patients with non-significant stenosis compared to "either positive" strategy, as it efficiently reduces the proportion of testing false positive subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. A 'difficult' insect allergy patient: reliable history of a sting, but all testing negative.

    PubMed

    Tracy, James M; Olsen, Jonathan A; Carlson, John

    2015-08-01

    Few conditions are as treatable as allergy to stinging insects, with venom immunotherapy (VIT) providing up to 98% protection to subsequent stings. The challenge with VIT is not in the treatment, but in the diagnosis. To offer VIT, one must determine a history of a systemic reaction to a stinging insect in conjunction with the presence venom-specific IgE. Current diagnostic methods, although sensitive and specific, are imperfect, and some newer testing options are not widely available. A conundrum occasionally faced is the patient with a reliable and compelling history of a systemic allergic reaction yet negative venom-specific testing. This diagnostic dilemma presents an opportunity to consider possible causes for this diagnostic challenge. Our evolving understanding of the role of occult mast cell disease may begin to help us understand this situation and develop appropriate management strategies. Venom-specific skin testing has long been the cornerstone of the evaluation of venom sensitivity and is often combined with in-vitro assays to add clarity, but even these occasionally may fall short. Exploring novel venom diagnostic testing methods may help to fill in some of the diagnostic gaps. Do currently available venom vaccines contain all the key venom species? Are there enough differences between insect species that we may simply be missing the relevant allergens? What is the significance of the antigenicity of carbohydrate moieties in venoms? What is the role of recombinant venom extracts? VIT is the definitive treatment for insect allergic individuals. To utilize VIT, identification of the relevant Hymenoptera is necessary. Unfortunately, this cannot always be accomplished. This deficiency can have several causes: a potential comorbid condition such as occult mast cell disease, limitations of currently available diagnostic resources, or testing vaccines with an insufficient coverage of relevant venom allergens. Exploring these potential causes may help to provide important insight into this important diagnostic conundrum. The use of a case report may help clarify this challenge.

  18. Evaluation of molecular markers for Phytophthora ramorum detection and identification: testing for specificity using a standardized library of isolates.

    PubMed

    Martin, F N; Coffey, M D; Zeller, K; Hamelin, R C; Tooley, P; Garbelotto, M; Hughes, K J D; Kubisiak, T; Bilodeau, G J; Levy, L; Blomquist, C; Berger, P H

    2009-04-01

    Given the importance of Phytophthora ramorum from a regulatory standpoint, it is imperative that molecular markers for pathogen detection are fully tested to evaluate their specificity in detection of the pathogen. In an effort to evaluate 11 reported diagnostic techniques, we assembled a standardized DNA library using accessions from the World Phytophthora Genetic Resource Collection for 315 isolates representing 60 described Phytophthora spp. as well as 11 taxonomically unclassified isolates. These were sent blind to collaborators in seven laboratories to evaluate published diagnostic procedures using conventional (based on internal transcribed spacer [ITS] and cytochrome oxidase gene [cox]1 and 2 spacer regions) and real-time polymerase chain reaction (based on ITS and cox1 and 2 spacer regions as well as beta-tubulin and elicitin genes). Single-strand conformation polymorphism (SSCP) analysis using an automated sequencer for data collection was also evaluated for identification of all species tested. In general, the procedures worked well, with varying levels of specificity observed among the different techniques. With few exceptions, all assays correctly identified all isolates of P. ramorum and low levels of false positives were observed for the mitochondrial cox spacer markers and most of the real-time assays based on nuclear markers (diagnostic specificity between 96.9 and 100%). The highest level of false positives was obtained with the conventional nested ITS procedure; however, this technique is not stand-alone and is used in conjunction with two other assays for diagnostic purposes. The results indicated that using multiple assays improved the accuracy of the results compared with looking at a single assay alone, in particular when the markers represented different genetic loci. The SSCP procedure accurately identified P. ramorum and was helpful in classification of a number of isolates to a species level. With one exception, all procedures accurately identified P. ramorum in blind evaluations of 60 field samples that included examples of plant infection by 11 other Phytophthora spp. The SSCP analysis identified eight of these species, with three identified to a species group.

  19. Evaluation of a diagnostic flow chart applying medical thoracoscopy, adenosine deaminase and T-SPOT.TB in diagnosis of tuberculous pleural effusion.

    PubMed

    He, Y; Zhang, W; Huang, T; Wang, X; Wang, M

    2015-10-01

    To evaluate a diagnostic flow chart applying medical thoracoscoy (MT), adenosine deaminase (ADA) and T-SPOT.TB in diagnosis of tuberculous pleural effusion (TPE) at a high TB burden country. 136 patients with pleural effusion (PE) were enrolled and divided into TPE and Non-TPE group. MT (histology), PE ADA and T-SPOT.TB were conducted on all patients. ROC analysis was performed for the best cut-off value of PE ADA in detection of TPE. The diagnostic flow chart applying MT, ADA and T-SPOT.TB was evaluated for improving the limitations of each diagnostic method. ROC analysis showed that the best cut-off value of PE ADA was 30U/L. The sensitivity and specificity of these tests were calculated respectively to be: 71.4% (58.5%-81.6%) and 100% (95.4-100.0%) for MT, 92.9% (83.0-97.2%) and 68.8% (57.9-77.9%) for T-SPOT.TB, and 80.0% (69.6-88.1%) and 92.9% (82.7-98.0%) for PE ADA. The sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, positive predictive value and negative predictive value of the diagnostic flow chart were 96.4% (87.9-99.0%), 96.3% (89.6-98.7%), 25.714, 0.037, 97.4 and 94.9, respectively. The diagnostic flow chart applying MT, ADA and T-SPOT.TB is an accurate and rapid diagnostic method in detection of TPE.

  20. Recommended reporting standards for test accuracy studies of infectious diseases of finfish, amphibians, molluscs and crustaceans: the STRADAS-aquatic checklist

    USGS Publications Warehouse

    Gardner, Ian A; Whittington, Richard J; Caraguel, Charles G B; Hick, Paul; Moody, Nicholas J G; Corbeil, Serge; Garver, Kyle A.; Warg, Janet V.; Arzul, Isabelle; Purcell, Maureen; St. J. Crane, Mark; Waltzek, Thomas B.; Olesen, Niels J; Lagno, Alicia Gallardo

    2016-01-01

    Complete and transparent reporting of key elements of diagnostic accuracy studies for infectious diseases in cultured and wild aquatic animals benefits end-users of these tests, enabling the rational design of surveillance programs, the assessment of test results from clinical cases and comparisons of diagnostic test performance. Based on deficiencies in the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines identified in a prior finfish study (Gardner et al. 2014), we adapted the Standards for Reporting of Animal Diagnostic Accuracy Studies—paratuberculosis (STRADAS-paraTB) checklist of 25 reporting items to increase their relevance to finfish, amphibians, molluscs, and crustaceans and provided examples and explanations for each item. The checklist, known as STRADAS-aquatic, was developed and refined by an expert group of 14 transdisciplinary scientists with experience in test evaluation studies using field and experimental samples, in operation of reference laboratories for aquatic animal pathogens, and in development of international aquatic animal health policy. The main changes to the STRADAS-paraTB checklist were to nomenclature related to the species, the addition of guidelines for experimental challenge studies, and the designation of some items as relevant only to experimental studies and ante-mortem tests. We believe that adoption of these guidelines will improve reporting of primary studies of test accuracy for aquatic animal diseases and facilitate assessment of their fitness-for-purpose. Given the importance of diagnostic tests to underpin the Sanitary and Phytosanitary agreement of the World Trade Organization, the principles outlined in this paper should be applied to other World Organisation for Animal Health (OIE)-relevant species.

  1. Recommended reporting standards for test accuracy studies of infectious diseases of finfish, amphibians, molluscs and crustaceans: the STRADAS-aquatic checklist.

    PubMed

    Gardner, Ian A; Whittington, Richard J; Caraguel, Charles G B; Hick, Paul; Moody, Nicholas J G; Corbeil, Serge; Garver, Kyle A; Warg, Janet V; Arzul, Isabelle; Purcell, Maureen K; Crane, Mark St J; Waltzek, Thomas B; Olesen, Niels J; Gallardo Lagno, Alicia

    2016-02-25

    Complete and transparent reporting of key elements of diagnostic accuracy studies for infectious diseases in cultured and wild aquatic animals benefits end-users of these tests, enabling the rational design of surveillance programs, the assessment of test results from clinical cases and comparisons of diagnostic test performance. Based on deficiencies in the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines identified in a prior finfish study (Gardner et al. 2014), we adapted the Standards for Reporting of Animal Diagnostic Accuracy Studies-paratuberculosis (STRADAS-paraTB) checklist of 25 reporting items to increase their relevance to finfish, amphibians, molluscs, and crustaceans and provided examples and explanations for each item. The checklist, known as STRADAS-aquatic, was developed and refined by an expert group of 14 transdisciplinary scientists with experience in test evaluation studies using field and experimental samples, in operation of reference laboratories for aquatic animal pathogens, and in development of international aquatic animal health policy. The main changes to the STRADAS-paraTB checklist were to nomenclature related to the species, the addition of guidelines for experimental challenge studies, and the designation of some items as relevant only to experimental studies and ante-mortem tests. We believe that adoption of these guidelines will improve reporting of primary studies of test accuracy for aquatic animal diseases and facilitate assessment of their fitness-for-purpose. Given the importance of diagnostic tests to underpin the Sanitary and Phytosanitary agreement of the World Trade Organization, the principles outlined in this paper should be applied to other World Organisation for Animal Health (OIE)-relevant species.

  2. Compare diagnostic tests using transformation-invariant smoothed ROC curves⋆

    PubMed Central

    Tang, Liansheng; Du, Pang; Wu, Chengqing

    2012-01-01

    Receiver operating characteristic (ROC) curve, plotting true positive rates against false positive rates as threshold varies, is an important tool for evaluating biomarkers in diagnostic medicine studies. By definition, ROC curve is monotone increasing from 0 to 1 and is invariant to any monotone transformation of test results. And it is often a curve with certain level of smoothness when test results from the diseased and non-diseased subjects follow continuous distributions. Most existing ROC curve estimation methods do not guarantee all of these properties. One of the exceptions is Du and Tang (2009) which applies certain monotone spline regression procedure to empirical ROC estimates. However, their method does not consider the inherent correlations between empirical ROC estimates. This makes the derivation of the asymptotic properties very difficult. In this paper we propose a penalized weighted least square estimation method, which incorporates the covariance between empirical ROC estimates as a weight matrix. The resulting estimator satisfies all the aforementioned properties, and we show that it is also consistent. Then a resampling approach is used to extend our method for comparisons of two or more diagnostic tests. Our simulations show a significantly improved performance over the existing method, especially for steep ROC curves. We then apply the proposed method to a cancer diagnostic study that compares several newly developed diagnostic biomarkers to a traditional one. PMID:22639484

  3. A fast Monte Carlo EM algorithm for estimation in latent class model analysis with an application to assess diagnostic accuracy for cervical neoplasia in women with AGC

    PubMed Central

    Kang, Le; Carter, Randy; Darcy, Kathleen; Kauderer, James; Liao, Shu-Yuan

    2013-01-01

    In this article we use a latent class model (LCM) with prevalence modeled as a function of covariates to assess diagnostic test accuracy in situations where the true disease status is not observed, but observations on three or more conditionally independent diagnostic tests are available. A fast Monte Carlo EM (MCEM) algorithm with binary (disease) diagnostic data is implemented to estimate parameters of interest; namely, sensitivity, specificity, and prevalence of the disease as a function of covariates. To obtain standard errors for confidence interval construction of estimated parameters, the missing information principle is applied to adjust information matrix estimates. We compare the adjusted information matrix based standard error estimates with the bootstrap standard error estimates both obtained using the fast MCEM algorithm through an extensive Monte Carlo study. Simulation demonstrates that the adjusted information matrix approach estimates the standard error similarly with the bootstrap methods under certain scenarios. The bootstrap percentile intervals have satisfactory coverage probabilities. We then apply the LCM analysis to a real data set of 122 subjects from a Gynecologic Oncology Group (GOG) study of significant cervical lesion (S-CL) diagnosis in women with atypical glandular cells of undetermined significance (AGC) to compare the diagnostic accuracy of a histology-based evaluation, a CA-IX biomarker-based test and a human papillomavirus (HPV) DNA test. PMID:24163493

  4. McGraw-Hill Programmed Reading Evaluation.

    ERIC Educational Resources Information Center

    Norfolk Public Schools, VA.

    One of the programs included in "Effective Reading Programs...," this program, begun in 1972, serves about 3,600 disadvantaged first through fourth grade students. The independent learning approach is featured in this program. Placement tests help teachers determine each child's needs, and diagnostic tests monitor student progress.…

  5. EVALUATION AND IMPORTANCE OF SELECTED MICROBIOLOGICAL METHODS IN THE DIAGNOSIS OF HUMAN BRUCELLOSIS

    PubMed Central

    Šiširak, Maida; Hukić, Mirsada

    2009-01-01

    Brucellosis is an important public health problem in Bosnia and Herzegovina. The diagnosis of bru-cellosis in the country without any experiences with this kind of infection may be very difficult. The aim of this study was to evaluate diagnostic methods: Rose Bengal test, blood cultures and ELISA IgM and IgG in the patients with brucellosis. The study included 91 brucellosis patients in the period 2004 to 2007. All the patients were treated at the Clinic for Infectious Diseases, University of Sarajevo Clinics Centre. Blood cultures were positive in 28/91 (30, 8%) patients. This method often needs a long period of incubation and specimens need to be obtained early. These limitations make serology the most useful tool for the laboratory diagnosis of Brucella infection. Rose Bengal is a rapid plate agglutination test, very sensitive irrespective of the stage of the disease. In our study, Rose Bengal test was positive in all patients 91/91 (100, 0%). Brucella IgM antibodies with ELISA were positive in 59/91 (64, 8%). Brucella IgG antibodies with ELISA were positive in 51/91 (56%). In order to determine the diagnostic value of the different tests, we compared the sensitivity among test-methods: Rose Bengal test-100.0%, blood culture-30.8%, ELISA IgM-64.8% and ELISA IgG-56.1%. Sensitivity of test methods was different in the different stages of illness. It is necessary to use combination of different tests such are blood culture, Rose Bengal test and ELISA in order to ensure the diagnosis. Rose Bengal test is excellent for the screening. Blood culture is a method of choice for the diagnosis acute infection. ELISA is a very good method for the diagnostic chronic disease and relapse. PMID:19754473

  6. Diagnostic Accuracy of Molecular Amplification Tests for Human African Trypanosomiasis—Systematic Review

    PubMed Central

    Boer, Kimberly R.; Dyserinck, Heleen C.; Büscher, Philippe; Schallig, Henk D. H. F.; Leeflang, Mariska M. G.

    2012-01-01

    Background A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Methodology Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. Results 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Conclusion Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately. PMID:22253934

  7. Diagnostic accuracy of molecular amplification tests for human African trypanosomiasis--systematic review.

    PubMed

    Mugasa, Claire M; Adams, Emily R; Boer, Kimberly R; Dyserinck, Heleen C; Büscher, Philippe; Schallig, Henk D H F; Leeflang, Mariska M G

    2012-01-01

    A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately.

  8. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    PubMed

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  9. TSI test

    MedlinePlus

    ... JE, ed. Guyton and Hall Textbook of Medical Physiology . 13th ed. Philadelphia, PA: Elsevier; 2016:chap 77. ... TF, Schlumberger MJ, Hay ID, Larsen PR. Thyroid physiology and diagnostic evaluation of patients with thyroid disorders. ...

  10. Effects of Home Gluten Immunogenic Peptide Testing on Children With Celiac Disease

    ClinicalTrials.gov

    2018-04-18

    Celiac Disease; Gluten Sensitivity; Gluten Enteropathy; Gastrointestinal Disease; Digestive System Disease; Diet Modification; Intestinal Disease; Malabsorption Syndromes; Patient Compliance; Diagnostic Self Evaluation; Quality of Life

  11. Diagnosing periprosthetic joint infection: has the era of the biomarker arrived?

    PubMed

    Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad

    2014-11-01

    The diagnosis of periprosthetic joint infection (PJI) remains a serious clinical challenge. There is a pressing need for improved diagnostic testing methods; biomarkers offer one potentially promising approach. We evaluated the diagnostic characteristics of 16 promising synovial fluid biomarkers for the diagnosis of PJI. Synovial fluid was collected from 95 patients meeting the inclusion criteria of this prospective diagnostic study. All patients were being evaluated for a revision hip or knee arthroplasty, including patients with systemic inflammatory disease and those already receiving antibiotic treatment. The Musculoskeletal Infection Society (MSIS) definition was used to classify 29 PJIs and 66 aseptic joints. Synovial fluid samples were tested by immunoassay for 16 biomarkers optimized for use in synovial fluid. Sensitivity, specificity, and receiver operating characteristic curve analysis were performed to assess for diagnostic performance. Five biomarkers, including human α-defensin 1-3, neutrophil elastase 2, bactericidal/permeability-increasing protein, neutrophil gelatinase-associated lipocalin, and lactoferrin, correctly predicted the MSIS classification of all patients in this study, with 100% sensitivity and specificity for the diagnosis of PJI. An additional eight biomarkers demonstrated excellent diagnostic strength, with an area under the curve of greater than 0.9. Synovial fluid biomarkers exhibit a high accuracy in diagnosing PJI, even when including patients with systemic inflammatory disease and those receiving antibiotic treatment. Considering that these biomarkers match the results of the more complex MSIS definition of PJI, we believe that synovial fluid biomarkers can be a valuable addition to the methods utilized for the diagnosis of infection. Level II, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  12. Outcomes of non-invasive diagnostic modalities for the detection of coronary artery disease: network meta-analysis of diagnostic randomised controlled trials

    PubMed Central

    Siontis, George CM; Mavridis, Dimitris; Greenwood, John P; Coles, Bernadette; Nikolakopoulou, Adriani; Jüni, Peter; Salanti, Georgia

    2018-01-01

    Abstract Objective To evaluate differences in downstream testing, coronary revascularisation, and clinical outcomes following non-invasive diagnostic modalities used to detect coronary artery disease. Design Systematic review and network meta-analysis. Data sources Medline, Medline in process, Embase, Cochrane Library for clinical trials, PubMed, Web of Science, SCOPUS, WHO International Clinical Trials Registry Platform, and Clinicaltrials.gov. Eligibility criteria for selecting studies Diagnostic randomised controlled trials comparing non-invasive diagnostic modalities in patients presenting with symptoms suggestive of low risk acute coronary syndrome or stable coronary artery disease. Data synthesis A random effects network meta-analysis synthesised available evidence from trials evaluating the effect of non-invasive diagnostic modalities on downstream testing and patient oriented outcomes in patients with suspected coronary artery disease. Modalities included exercise electrocardiograms, stress echocardiography, single photon emission computed tomography-myocardial perfusion imaging, real time myocardial contrast echocardiography, coronary computed tomographic angiography, and cardiovascular magnetic resonance. Unpublished outcome data were obtained from 11 trials. Results 18 trials of patients with low risk acute coronary syndrome (n=11 329) and 12 trials of those with suspected stable coronary artery disease (n=22 062) were included. Among patients with low risk acute coronary syndrome, stress echocardiography, cardiovascular magnetic resonance, and exercise electrocardiograms resulted in fewer invasive referrals for coronary angiography than coronary computed tomographic angiography (odds ratio 0.28 (95% confidence interval 0.14 to 0.57), 0.32 (0.15 to 0.71), and 0.53 (0.28 to 1.00), respectively). There was no effect on the subsequent risk of myocardial infarction, but estimates were imprecise. Heterogeneity and inconsistency were low. In patients with suspected stable coronary artery disease, an initial diagnostic strategy of stress echocardiography or single photon emission computed tomography-myocardial perfusion imaging resulted in fewer downstream tests than coronary computed tomographic angiography (0.24 (0.08 to 0.74) and 0.57 (0.37 to 0.87), respectively). However, exercise electrocardiograms yielded the highest downstream testing rate. Estimates for death and myocardial infarction were imprecise without clear discrimination between strategies. Conclusions For patients with low risk acute coronary syndrome, an initial diagnostic strategy of stress echocardiography or cardiovascular magnetic resonance is associated with fewer referrals for invasive coronary angiography and revascularisation procedures than non-invasive anatomical testing, without apparent impact on the future risk of myocardial infarction. For suspected stable coronary artery disease, there was no clear discrimination between diagnostic strategies regarding the subsequent need for invasive coronary angiography, and differences in the risk of myocardial infarction cannot be ruled out. Systematic review registration PROSPERO registry no CRD42016049442. PMID:29467161

  13. Cost-effective Diagnostic Checklists for Meningitis in Resource Limited Settings

    PubMed Central

    Durski, Kara N.; Kuntz, Karen M.; Yasukawa, Kosuke; Virnig, Beth A.; Meya, David B.; Boulware, David R.

    2013-01-01

    Background Checklists can standardize patient care, reduce errors, and improve health outcomes. For meningitis in resource-limited settings, with high patient loads and limited financial resources, CNS diagnostic algorithms may be useful to guide diagnosis and treatment. However, the cost-effectiveness of such algorithms is unknown. Methods We used decision analysis methodology to evaluate the costs, diagnostic yield, and cost-effectiveness of diagnostic strategies for adults with suspected meningitis in resource limited settings with moderate/high HIV prevalence. We considered three strategies: 1) comprehensive “shotgun” approach of utilizing all routine tests; 2) “stepwise” strategy with tests performed in a specific order with additional TB diagnostics; 3) “minimalist” strategy of sequential ordering of high-yield tests only. Each strategy resulted in one of four meningitis diagnoses: bacterial (4%), cryptococcal (59%), TB (8%), or other (aseptic) meningitis (29%). In model development, we utilized prevalence data from two Ugandan sites and published data on test performance. We validated the strategies with data from Malawi, South Africa, and Zimbabwe. Results The current comprehensive testing strategy resulted in 93.3% correct meningitis diagnoses costing $32.00/patient. A stepwise strategy had 93.8% correct diagnoses costing an average of $9.72/patient, and a minimalist strategy had 91.1% correct diagnoses costing an average of $6.17/patient. The incremental cost effectiveness ratio was $133 per additional correct diagnosis for the stepwise over minimalist strategy. Conclusions Through strategically choosing the order and type of testing coupled with disease prevalence rates, algorithms can deliver more care more efficiently. The algorithms presented herein are generalizable to East Africa and Southern Africa. PMID:23466647

  14. [Evaluation of peruvian money test in screening of cognitive impairment among older adults].

    PubMed

    Oscanoa, Teodoro J; Cieza, Edwin; Parodi, José F; Paredes, Napoleón

    2016-03-01

    Objectives To evaluate the Peruvian adaptation of the money test (Eurotest) for identifying cognitive impairment among >60-year-old adults. Materials and methods This is a phase I study of diagnostic test, with a convenience sampling and calculation of the test´s sensitivity and specificity, based on a pretest prevalence of 50%. The criteria of the Diagnostic and Statistical Manual of Mental Disorders (DSM IV) and Global Deterioration Scale (GDS) were used for the operational definition of patients with cognitive impairment. Receiver operating characteristic (ROC) curve analysis was used to identify the optimal cut-off value. Results The study evaluated 42 cases and 42 controls; there was no significant difference between age (77.88 ± 6.01 years vs. 6.49 76.14 ± years) and years of education (13.69 ± 3.70 years vs. 8.17 ± 4.71 years). The Peruvian version of the Eurotest has a sensitivity of 90.5% and specificity of 83.3% with cut-off value of 24. Conclusions The Peruvian adapted version of the Eurotest, called prueba de la moneda peruana could be useful in screening for cognitive impairment among older adults.

  15. An adaptive toolkit for image quality evaluation in system performance test of digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Zhang, Guozhi; Petrov, Dimitar; Marshall, Nicholas; Bosmans, Hilde

    2017-03-01

    Digital breast tomosynthesis (DBT) is a relatively new diagnostic imaging modality for women. Currently, various models of DBT systems are available on the market and the number of installations is rapidly increasing. EUREF, the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services, has proposed a preliminary Guideline - protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, with an ultimate aim of providing limiting values guaranteeing proper performance for different applications of DBT. In this work, we introduce an adaptive toolkit developed in accordance with this guideline to facilitate the process of image quality evaluation in DBT performance test. This toolkit implements robust algorithms to quantify various technical parameters of DBT images and provides a convenient user interface in practice. Each test is built into a separate module with configurations set corresponding to the European guideline, which can be easily adapted to different settings and extended with additional tests. This toolkit largely improves the efficiency for image quality evaluation of DBT. It is also going to evolve with the development of protocols in quality control of DBT systems.

  16. Comparison of 2-limb versus 3-limb electrodiagnostic studies in the evaluation of chronic inflammatory demyelinating polyneuropathy.

    PubMed

    Vo, Mary L; Hanineva, Aneliya; Chin, Russell L; Carey, Bridget T; Latov, Norman; Langsdorf, Jennifer A

    2015-04-01

    European Federation of Neurological Societies/Peripheral Nerve Society electrodiagnostic (EDx) criteria for the definite diagnosis of chronic inflammatory demyelinating polyneuropathy (CIDP) require the presence of demyelinating findings (DF) in at least 2 nerves. Data are lacking, however, regarding the optimal number of nerves to test. We retrospectively reviewed EDx data from 53 patients with CIDP and compared the number of DF found on 2- and 3-limb testing. A median of 3 (range 2-5) DF were found on 2-limb testing compared with 5 (range 4-7) DF when 3 limbs were evaluated. Two-limb EDx studies were sufficient to diagnose definite CIDP in 92.3% of typical, 84.2% of asymmetric, and 66.7% of distal phenotypes. Testing a third limb increased diagnostic certainty in 11 patients (20.8%) to definite CIDP. Three-limb testing may increase diagnostic sensitivity of definite CIDP, especially in patients with atypical phenotypes. Larger prospective studies are needed to better assess the benefit of performing 3-limb EDx studies. © 2014 Wiley Periodicals, Inc.

  17. Indications for endoscopic third ventriculostomy in normal pressure hydrocephalus.

    PubMed

    Paidakakos, Nikolaos; Borgarello, S; Naddeo, M

    2012-01-01

    Controversies remain regarding the proper diagnostic studies and prediction of outcome in patients with normal pressure hydrocephalus (NPH), and their management remains controversial. We propose a preoperative assessment routine the aim of which is to correctly select NPH patients, and to differentiate between them in terms of surgical treatment, identifying probable endoscopic third ventriculostomy (ETV) responders. We prospectively considered a group of 44 patients with suspected NPH on the basis of clinical symptoms and neuroradiological evidence, who have undergone supplemental diagnostic testing (tap test, external lumbar drainage, cerebrospinal fluid outflow resistance [Rout] determination through lumbar and ventricular infusion test). All 44 of these patients were treated with either shunt procedures or ETV. To choose the kind of treatment (shunt or ETV), we evaluated the individual response during infusion tests. The efficacy of both surgical techniques was approximately 70%, with a significantly lower complication rate for ETV. We evaluated the correlation between the various tests and the postoperative outcomes both for shunting and for ETV. Rout proved useful for preoperative assessment and choice of treatment. In carefully selected patients, ETV had qualitative results similar to shunting, presenting significantly fewer complications.

  18. Potential impact of amyloid imaging on diagnosis and intended management in patients with progressive cognitive decline.

    PubMed

    Grundman, Michael; Pontecorvo, Michael J; Salloway, Stephen P; Doraiswamy, P Murali; Fleisher, Adam S; Sadowsky, Carl H; Nair, Anil K; Siderowf, Andrew; Lu, Ming; Arora, Anupa K; Agbulos, Abigail; Flitter, Matthew L; Krautkramer, Michael J; Sarsour, Khaled; Skovronsky, Daniel M; Mintun, Mark A

    2013-01-01

    Florbetapir F18 has been approved by the Food and Drug Administration for in vivo assessment of amyloid pathology in patients undergoing evaluation for Alzheimer disease (AD). The aim of this study was to determine the impact of amyloid imaging on the diagnoses and management of patients undergoing evaluation for cognitive decline. Patients were recruited to participate at 19 clinical sites. The site physician provided a provisional diagnosis, an estimate of their diagnostic confidence, and their plan for diagnostic evaluation and management both before and after receiving the results from amyloid imaging with florbetapir F18. Analyses compared the frequency of AD and non-AD diagnoses, plans for ancillary testing, and intended patient management before and after florbetapir imaging. A total of 229 patients participated in the trial (113 amyloid positive, 116 amyloid negative). After receiving the results of the florbetapir scan, diagnosis changed in 125/229, or 54.6% [95% confidence intervals (CI), 48.1%-60.9%], of cases, and diagnostic confidence increased by an average of 21.6% (95% CI, 18.3%-24.8%). A total of 199/229 or 86.9% (95% CI, 81.9%-90.7%) of cases had at least 1 change in their management plan. Intended cholinesterase inhibitor or memantine treatment increased by 17.7% (95% CI, 11.8%-25.8%) of all cases with positive scans and decreased by 23.3% (95% CI, 16.5%-31.8%) of all those with negative scans. Among subjects who had not yet undergone a completed work up, planned brain structural imaging (computed tomographic/magnetic resonance imaging) decreased by 24.4% (95% CI, 17.5%-32.8%) and planned neuropsychological testing decreased by 32.8% (95% CI, 25.0%-41.6%). In summary, amyloid imaging results altered physician's diagnostic thinking, intended testing, and management of patients undergoing evaluation for cognitive decline.

  19. Performance of an HRP-2 Rapid Diagnostic Test in Nigerian Children Less Than 5 Years of Age

    PubMed Central

    Ajumobi, Olufemi; Sabitu, Kabir; Nguku, Patrick; Kwaga, Jacob; Ntadom, Godwin; Gitta, Sheba; Elizeus, Rutebemberwa; Oyibo, Wellington; Nsubuga, Peter; Maire, Mark; Poggensee, Gabriele

    2015-01-01

    The diagnostic performance of histidine-rich protein 2 (HRP-2)–based malaria rapid diagnostic test (RDT) was evaluated in a mesoendemic area for malaria, Kaduna, Nigeria. We compared RDT results with expert microscopy results of blood samples from 295 febrile children under 5 years. Overall, 11.9% (35/295) tested positive with RDT compared with 10.5% (31/295) by microscopy: sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100%, 98.5%, 88.6%, and 100%, respectively. The RDT sensitivity was not affected by transmission season, parasite density, and age. Specificity and positive PV decreased slightly during the high-transmission season (97.5% and 83.3%). The RDT test positivity rates in the low- and high-transmission seasons were 9.4% and 13.5%, respectively. Overall, the test performance of this RDT was satisfactory. The findings of a low proportion of RDT false positives, no invalid and no false-negative results should validate the performance of RDTs in this context. PMID:25711608

  20. Evaluation of 9 rapid diagnostic tests for screening HIV infection, in Lomé, Togo.

    PubMed

    Dagnra, A Y; Dossim, S; Salou, M; Nyasenu, T; Ali-Edje, K; Ouro-Médeli, A; Doufan, M; Ehlan, A; Prince-David, M

    2014-12-01

    HIV rapid diagnostic tests (RDT) could be greatly contributive for a universal access to HIV diagnosis. However, according to the WHO, these tests need to be assessed before they can be used in routine. We assessed 9 RDT in routine clinical use between 2009 and 2013. The sensitivity and specificity observed for 7 tests were≥99% and≥98%, respectively: FIRST RESPONSE HIV1-2-O PMC Medical, India, GENIE Fast HIV 1-2 and GENIE™ III HIV(1/2) Bio-Rad, France, HIV TRI-DOT+Ag;J. Mitra, INDIA; SD BIOLINE HIV(1/2) 3.0 and SD BIOLINE HIV/SYPHILIS DUO Standard Diagnostic, Korea; and VIKIA HIV(1/2); BioMérieux, France. Two tests had performances inferior to WHO recommendations: INSTI HIV1/2 Biolytical Canada; sensitivity=97.8% and HEXAGON HIV HUMAN GmbH Germany; specificity=94.8%. Seven of 9 RDT had excellent performances. Nevertheless, they can be used only after training staff, and taking into account national algorithm for their safe use. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Diagnosis of stinging insect allergy: utility of cellular in-vitro tests.

    PubMed

    Scherer, Kathrin; Bircher, Andreas J; Heijnen, Ingmar Afm

    2009-08-01

    Diagnosis of stinging insect allergy is based on a detailed history, venom skin tests, and detection of venom-specific IgE. As an additional diagnostic tool, basophil responsiveness to venom allergens has been shown to be helpful in selected patients. This review summarizes the current diagnostic procedures for stinging insect allergy and discusses the latest developments in cellular in-vitro tests. Cellular assays have been evaluated in patients with Hymenoptera venom allergy. The diagnostic performance of the cellular mediator release test is similar to that of the flow cytometric basophil activation test (BAT), but the BAT has been the most intensively studied. BAT offers the possibility to assess basophil reactivity to allergens in their natural environment and to simultaneously analyze surface marker expression and intracellular signaling. It has been demonstrated that BAT represents a valuable additional diagnostic tool in selected patients when used in combination with other well established tests. A major limitation is the current lack of unified, standardized protocols. Flow cytometry offers huge possibilities to enhance knowledge of basophil functions. The BAT may be used as an additional test to confirm the diagnosis of stinging insect allergy in selected patients, provided that it is performed by an experienced laboratory using a validated assay. Test results have to be interpreted by clinicians familiar with the methodological aspects. The utility of the BAT to confirm allergy diagnosis and to predict the risk of subsequent systemic reactions may be improved by combined analysis of multiple surface markers and intracellular signaling pathways.

  2. Preliminary evaluation of the impact of a Web-based HIV testing programme in Abruzzo Region on the prevention of late HIV presentation and associated mortality.

    PubMed

    Polilli, Ennio; Sozio, Federica; Di Stefano, Paola; Clerico, Luigi; Di Iorio, Giancarlo; Parruti, Giustino

    2018-04-01

    This study aimed to analyze the efficacy of a Web-based testing programme in terms of the prevention of late HIV presentation. The clinical characteristics of patients diagnosed with HIV via the Web-based testing programme were compared to those of patients diagnosed in parallel via standard diagnostic care procedures. This study included the clinical and demographic data of newly diagnosed HIV patients enrolled at the study clinic between February 2014 and June 2017. These patients were diagnosed either via standard diagnostic procedures or as a result of the Web-based testing programme. Eighty-eight new cases of HIV were consecutively enrolled; their mean age was 39.1±13.0 years. Fifty-nine patients (67%) were diagnosed through standard diagnostic procedures and 29 (33%) patients came from the Web-based testing programme. Late presentation (62% vs. 34%, p=0.01) and AIDS-defining conditions at presentation (13 vs. 1, p=0.02) were significantly more frequent in the standard care group than in the Web-based group; four of 13 patients with AIDS diagnosed under standard diagnostic procedures died, versus none in the Web-based testing group (p<0.001). Web-based recruitment for voluntary and free HIV testing helped to diagnose patients with less advanced HIV disease and no risk of death, from all at-risk groups, in comparison with standard care testing. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Evaluation of the LDBIO point of care test for the combined detection of toxoplasmic IgG and IgM.

    PubMed

    Chapey, Emmanuelle; Wallon, Martine; Peyron, François

    2017-01-01

    The toxoplasma ICT IgG-IgM rapid diagnostic test for the simultaneous detection of specific toxoplasmic immunoglobulin (Ig) G and IgM was compared with the Architect fully automated chemiluminescence test. Four hundred sera were included, among which 248 scored negative in Architect. The cassettes were easily read with the naked eye. Diagnostic sensitivity and specificity were 97% and 96%, respectively. The test scored 8 false-positive IgG and yielded negative results in 3 sera displaying unspecific IgM in Architect. The LDBIO appears to be a reliable first line test, although the false-positive results for IgG deserve further investigation. Such an easily performed test could be used advantageously for screening for toxoplasmosis in pregnant women. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Diagnostic accuracy of the Eurotest for dementia: a naturalistic, multicenter phase II study

    PubMed Central

    Carnero-Pardo, Cristobal; Gurpegui, Manuel; Sanchez-Cantalejo, Emilio; Frank, Ana; Mola, Santiago; Barquero, M Sagrario; Montoro-Rios, M Teresa

    2006-01-01

    Background Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. Methods A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn), specificity (Sp) and area under the ROC curves (aROC) with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. Results Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84–0.96), Sp = 0.82 (0.77–0.85), and aROC = 0.93 (0.91–0.95). Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. Conclusion This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity. PMID:16606455

  5. Time-resolved fluorescence monitoring of cholesterol in peripheral blood mononuclear cells

    NASA Astrophysics Data System (ADS)

    Martinakova, Z.; Horilova, J.; Lajdova, I.; Marcek Chorvatova, A.

    2014-12-01

    Precise evaluation of intracellular cholesterol distribution is crucial for improving diagnostics of diseased states associated with cholesterol alteration. Time-resolved fluorescence techniques are tested for non-invasive investigation of cholesterol in living cells. Fluorescent probe NBD attached to cholesterol was employed to evaluate cholesterol distribution in peripheral blood mononuclear cells (PBMC) isolated from the human blood. Fluorescence Lifetime Imaging Microscopy (FLIM) was successfully applied to simultaneously monitor the spatial distribution and the timeresolved characteristics of the NBD-cholesterol fluorescence in PBMC. Gathered data are the first step in the development of a new perspective non-invasive diagnostic method for evaluation of cholesterol modifications in diseases associated with disorders of lipid metabolism.

  6. A traditionally administered short course failed to improve medical students' diagnostic performance. A quantitative evaluation of diagnostic thinking.

    PubMed

    Noguchi, Yoshinori; Matsui, Kunihiko; Imura, Hiroshi; Kiyota, Masatomo; Fukui, Tsuguya

    2004-05-01

    Quite often medical students or novice residents have difficulty in ruling out diseases even though they are quite unlikely and, due to this difficulty, such students and novice residents unnecessarily repeat laboratory or imaging tests. To explore whether or not a carefully designed short training course teaching Bayesian probabilistic thinking improves the diagnostic ability of medical students. Ninety students at 2 medical schools were presented with clinical scenarios of coronary artery disease corresponding to high, low, and intermediate pretest probabilities. The students' estimates of test characteristics of exercise stress test, and pretest and posttest probability for each scenario were evaluated before and after the short course. The pretest probability estimates by the students, as well as their proficiency in applying Bayes's theorem, were improved in the high pretest probability scenario after the short course. However, estimates of pretest probability in the low pretest probability scenario, and their proficiency in applying Bayes's theorem in the intermediate and low pretest probability scenarios, showed essentially no improvement. A carefully designed, but traditionally administered, short course could not improve the students' abilities in estimating pretest probability in a low pretest probability setting, and subsequently students remained incompetent in ruling out disease. We need to develop educational methods that cultivate a well-balanced clinical sense to enable students to choose a suitable diagnostic strategy as needed in a clinical setting without being one-sided to the "rule-in conscious paradigm."

  7. A standard test case suite for two-dimensional linear transport on the sphere: results from a collection of state-of-the-art schemes

    NASA Astrophysics Data System (ADS)

    Lauritzen, P. H.; Ullrich, P. A.; Jablonowski, C.; Bosler, P. A.; Calhoun, D.; Conley, A. J.; Enomoto, T.; Dong, L.; Dubey, S.; Guba, O.; Hansen, A. B.; Kaas, E.; Kent, J.; Lamarque, J.-F.; Prather, M. J.; Reinert, D.; Shashkin, V. V.; Skamarock, W. C.; Sørensen, B.; Taylor, M. A.; Tolstykh, M. A.

    2013-09-01

    Recently, a standard test case suite for 2-D linear transport on the sphere was proposed to assess important aspects of accuracy in geophysical fluid dynamics with a "minimal" set of idealized model configurations/runs/diagnostics. Here we present results from 19 state-of-the-art transport scheme formulations based on finite-difference/finite-volume methods as well as emerging (in the context of atmospheric/oceanographic sciences) Galerkin methods. Discretization grids range from traditional regular latitude-longitude grids to more isotropic domain discretizations such as icosahedral and cubed-sphere tessellations of the sphere. The schemes are evaluated using a wide range of diagnostics in idealized flow environments. Accuracy is assessed in single- and two-tracer configurations using conventional error norms as well as novel diagnostics designed for climate and climate-chemistry applications. In addition, algorithmic considerations that may be important for computational efficiency are reported on. The latter is inevitably computing platform dependent, The ensemble of results from a wide variety of schemes presented here helps shed light on the ability of the test case suite diagnostics and flow settings to discriminate between algorithms and provide insights into accuracy in the context of global atmospheric/ocean modeling. A library of benchmark results is provided to facilitate scheme intercomparison and model development. Simple software and data-sets are made available to facilitate the process of model evaluation and scheme intercomparison.

  8. A standard test case suite for two-dimensional linear transport on the sphere: results from a collection of state-of-the-art schemes

    NASA Astrophysics Data System (ADS)

    Lauritzen, P. H.; Ullrich, P. A.; Jablonowski, C.; Bosler, P. A.; Calhoun, D.; Conley, A. J.; Enomoto, T.; Dong, L.; Dubey, S.; Guba, O.; Hansen, A. B.; Kaas, E.; Kent, J.; Lamarque, J.-F.; Prather, M. J.; Reinert, D.; Shashkin, V. V.; Skamarock, W. C.; Sørensen, B.; Taylor, M. A.; Tolstykh, M. A.

    2014-01-01

    Recently, a standard test case suite for 2-D linear transport on the sphere was proposed to assess important aspects of accuracy in geophysical fluid dynamics with a "minimal" set of idealized model configurations/runs/diagnostics. Here we present results from 19 state-of-the-art transport scheme formulations based on finite-difference/finite-volume methods as well as emerging (in the context of atmospheric/oceanographic sciences) Galerkin methods. Discretization grids range from traditional regular latitude-longitude grids to more isotropic domain discretizations such as icosahedral and cubed-sphere tessellations of the sphere. The schemes are evaluated using a wide range of diagnostics in idealized flow environments. Accuracy is assessed in single- and two-tracer configurations using conventional error norms as well as novel diagnostics designed for climate and climate-chemistry applications. In addition, algorithmic considerations that may be important for computational efficiency are reported on. The latter is inevitably computing platform dependent. The ensemble of results from a wide variety of schemes presented here helps shed light on the ability of the test case suite diagnostics and flow settings to discriminate between algorithms and provide insights into accuracy in the context of global atmospheric/ocean modeling. A library of benchmark results is provided to facilitate scheme intercomparison and model development. Simple software and data sets are made available to facilitate the process of model evaluation and scheme intercomparison.

  9. Determinants of Practice Patterns and Quality Gaps in Lung Cancer Staging and Diagnosis

    PubMed Central

    Niu, Jiangong; Elting, Linda S.; Buchholz, Thomas A.; Giordano, Sharon H.

    2014-01-01

    Background: Guidelines recommend mediastinal lymph node sampling as the first invasive diagnostic procedure in patients with suspected lung cancer with mediastinal lymphadenopathy without distant metastases. Methods: Patients were a retrospective cohort of 15,316 patients with lung cancer with regional spread without metastatic disease in the National Cancer Institute’s Surveillance, Epidemiology, and End Results (SEER) or Texas Cancer Registry Medicare-linked databases. Patients were categorized based on the sequencing of invasive diagnostic tests performed: (1) evaluation consistent with guidelines, mediastinal sampling done first; (2) evaluation inconsistent with guidelines, non-small cell lung cancer (NSCLC) present, mediastinal sampling performed but not as part of the first invasive test; (3) evaluation inconsistent with guidelines, NSCLC present, mediastinal sampling never done; and (4) evaluation inconsistent with guidelines, small cell lung cancer. The primary outcome was whether guideline-consistent care was delivered. Secondary outcomes included whether patients with NSCLC ever had mediastinal sampling and use of transbronchial needle aspiration (TBNA) among pulmonologists. Results: Only 21% of patients had a diagnostic evaluation consistent with guidelines. Only 56% of patients with NSCLC had mediastinal sampling prior to treatment. There was significant regional variability in guideline-consistent care (range, 12%-29%). Guideline-consistent care was associated with lower patient age, metropolitan areas, and if the physician ordering or performing the test was male, trained in the United States, had seen more patients with lung cancer, and was a pulmonologist or thoracic surgeon who had graduated more recently. More recent pulmonary graduates were also more likely to perform TBNA (P < .001). Conclusions: Guideline-consistent care varied regionally and was associated with physician-level factors, suggesting that a lack of effective physician training may be contributing to the quality gaps observed. PMID:24202651

  10. Evaluation of a blocking ELISA for the detection of antibodies against Lawsonia intracellularis in pig sera.

    PubMed

    Jacobson, Magdalena; Wallgren, Per; Nordengrahn, Ann; Merza, Malik; Emanuelson, Ulf

    2011-04-01

    Lawsonia intracellularis is a common cause of chronic diarrhoea and poor performance in young growing pigs. Diagnosis of this obligate intracellular bacterium is based on the demonstration of the microbe or microbial DNA in tissue specimens or faecal samples, or the demonstration of L. intracellularis-specific antibodies in sera. The aim of the present study was to evaluate a blocking ELISA in the detection of serum antibodies to L. intracellularis, by comparison to the previously widely used immunofluorescent antibody test (IFAT). Sera were collected from 176 pigs aged 8-12 weeks originating from 24 herds with or without problems with diarrhoea and poor performance in young growing pigs. Sera were analyzed by the blocking ELISA and by IFAT. Bayesian modelling techniques were used to account for the absence of a gold standard test and the results of the blocking ELISA was modelled against the IFAT test with a "2 dependent tests, 2 populations, no gold standard" model. At the finally selected cut-off value of percent inhibition (PI) 35, the diagnostic sensitivity of the blocking ELISA was 72% and the diagnostic specificity was 93%. The positive predictive value was 0.82 and the negative predictive value was 0.89, at the observed prevalence of 33.5%. The sensitivity and specificity as evaluated by Bayesian statistic techniques differed from that previously reported. Properties of diagnostic tests may well vary between countries, laboratories and among populations of animals. In the absence of a true gold standard, the importance of validating new methods by appropriate statistical methods and with respect to the target population must be emphasized.

  11. Practical mental health assessment in primary care. Validity and utility of the Quick PsychoDiagnostics Panel.

    PubMed

    Shedler, J; Beck, A; Bensen, S

    2000-07-01

    Many case-finding instruments are available to help primary care physicians (PCPs) diagnose depression, but they are not widely used. Physicians often consider these instruments too time consuming or feel they do not provide sufficient diagnostic information. Our study examined the validity and utility of the Quick PsychoDiagnostics (QPD) Panel, an automated mental health test designed to meet the special needs of PCPs. The test screens for 9 common psychiatric disorders and requires no physician time to administer or score. We evaluated criterion validity relative to the Structured Clinical Interview for DSM-IV (SCID), and evaluated convergent validity by correlating QPD Panel scores with established mental health measures. Sensitivity to change was examined by readministering the test to patients pretreatment and posttreatment. Utility was evaluated through physician and patient satisfaction surveys. For major depression, sensitivity and specificity were 81% and 96%, respectively. For other disorders, sensitivities ranged from 69% to 98%, and specificities ranged from 90% to 97%. The depression severity score correlated highly with the Beck, Hamilton, Zung, and CES-D depression scales, and the anxiety score correlated highly with the Spielberger State-Trait Anxiety Inventory and the anxiety subscale of the Symptom Checklist 90 (Ps <.001). The test was sensitive to change. All PCPs agreed or strongly agreed that the QPD Panel "is convenient and easy to use," "can be used immediately by any physician," and "helps provide better patient care." Patients also rated the test favorably. The QPD Panel is a valid mental health assessment tool that can diagnose a range of common psychiatric disorders and is practical for routine use in primary care.

  12. Integrating Oil Debris and Vibration Gear Damage Detection Technologies Using Fuzzy Logic

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Afjeh, Abdollah A.

    2002-01-01

    A diagnostic tool for detecting damage to spur gears was developed. Two different measurement technologies, wear debris analysis and vibration, were integrated into a health monitoring system for detecting surface fatigue pitting damage on gears. This integrated system showed improved detection and decision-making capabilities as compared to using individual measurement technologies. This diagnostic tool was developed and evaluated experimentally by collecting vibration and oil debris data from fatigue tests performed in the NASA Glenn Spur Gear Fatigue Test Rig. Experimental data were collected during experiments performed in this test rig with and without pitting. Results show combining the two measurement technologies improves the detection of pitting damage on spur gears.

  13. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  14. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  15. On the Estimation of Disease Prevalence by Latent Class Models for Screening Studies Using Two Screening Tests with Categorical Disease Status Verified in Test Positives Only

    PubMed Central

    Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.

    2010-01-01

    Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614

  16. Diagnostics of Technical Condition of Gear Units of Belt Conveyors for the Aggregate of Methods of Nondestructive Testing

    NASA Astrophysics Data System (ADS)

    Kuzin, Evgeny G.; Gerike, Boris L.; Drozdenko, Yuriy V.; Lupiy, Michael G.; Grigoryeva, Natalya V.

    2017-10-01

    The article reviews the issues of complex use of methods of technical diagnostics of gearboxes for belt conveyors, with the aim of creating an effective system of maintenance. The article is showing the results of the evaluation of the technical condition of the drives of belt conveyors based on vibration monitoring and thermal parameters, and analysis of lubricating oil.

  17. Diagnostic performance of automated liquid culture and molecular line probe assay in smear-negative pulmonary tuberculosis.

    PubMed

    Kotwal, Aarti; Biswas, Debasis; Raghuvanshi, Shailendra; Sindhwani, Girish; Kakati, Barnali; Sharma, Shweta

    2017-04-01

    The diagnosis of smear-negative pulmonary tuberculosis (PTB) is particularly challenging, and automated liquid culture and molecular line probe assays (LPA) may prove particularly useful. The objective of our study was to evaluate the diagnostic potential of automated liquid culture (ALC) technology and commercial LPA in sputum smear-negative PTB suspects. Spot sputum samples were collected from 145 chest-symptomatic smear-negative patients and subjected to ALC, direct drug susceptibility test (DST) testing and LPA, as per manufacturers' instructions. A diagnostic yield of 26.2% was observed among sputum smear-negative TB suspects with 47.4% of the culture isolates being either INH- and/or rifampicin-resistant. Complete agreement was observed between the results of ALC assay and LPA except for two isolates which demonstrated sensitivity to INH and rifampicin at direct DST but were rifampicin-resistant in LPA. Two novel mutations were also detected among the multidrug isolates by LPA. In view of the diagnostic challenges associated with the diagnosis of TB in sputum smear-negative patients, our study demonstrates the applicability of ALC and LPA in establishing diagnostic evidence of TB.

  18. Development and Testing of an LED-Based Near-Infrared Sensor for Human Kidney Tumor Diagnostics

    PubMed Central

    Zabarylo, Urszula; Kirsanov, Dmitry; Belikova, Valeria; Ageev, Vladimir; Usenov, Iskander; Galyanin, Vladislav; Minet, Olaf; Sakharova, Tatiana; Danielyan, Georgy; Feliksberger, Elena; Artyushenko, Viacheslav

    2017-01-01

    Optical spectroscopy is increasingly used for cancer diagnostics. Tumor detection feasibility in human kidney samples using mid- and near-infrared (NIR) spectroscopy, fluorescence spectroscopy, and Raman spectroscopy has been reported (Artyushenko et al., Spectral fiber sensors for cancer diagnostics in vitro. In Proceedings of the European Conference on Biomedical Optics, Munich, Germany, 21–25 June 2015). In the present work, a simplification of the NIR spectroscopic analysis for cancer diagnostics was studied. The conventional high-resolution NIR spectroscopic method of kidney tumor diagnostics was replaced by a compact optical sensing device constructively represented by a set of four light-emitting diodes (LEDs) at selected wavelengths and one detecting photodiode. Two sensor prototypes were tested using 14 in vitro clinical samples of 7 different patients. Statistical data evaluation using principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) confirmed the general applicability of the LED-based sensing approach to kidney tumor detection. An additional validation of the results was performed by means of sample permutation. PMID:28825612

  19. A global comparative evaluation of commercial immunochromatographic rapid diagnostic tests for visceral leishmaniasis.

    PubMed

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen

    2012-11-15

    Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Commercial VL RDTs containing bound rK39 or rKE16 antigen were evaluated using archived human sera from confirmed VL cases (n = 750) and endemic non-VL controls (n = 754) in the Indian subcontinent (ISC), Brazil, and East Africa to assess sensitivity and specificity with 95% confidence intervals. A subset of RDTs were also evaluated after 60 days' heat incubation (37°C, 45°C). Interlot and interobserver variability was assessed. All test brands performed well against ISC panels (sensitivity range, 92.8%-100%; specificity range, 96%-100%); however, sensitivity was lower against Brazil and East African panels (61.5%-91% and 36.8%-87.2%, respectively). Specificity was consistently > 95% in Brazil and ranged between 90.8% and 98% in East Africa. Performance of some products was adversely affected by high temperatures. Agreement between lots and readers was good to excellent (κ > 0.73-0.99). Diagnostic accuracy of VL RDTs varies between the major endemic regions. Many tests performed well and showed good heat stability in the ISC; however, reduced sensitivity against Brazilian and East African panels suggests that in these regions, used alone, several RDTs are inadequate for excluding a VL diagnosis. More research is needed to assess ease of use and to compare performance using whole blood instead of serum and in patients coinfected with human immunodeficiency virus.

  20. Beamlet diagnostics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Theys, M.

    1994-05-06

    Beamlet is a high power laser currently being built at Lawrence Livermore National Lab as a proof of concept for the National Ignition Facility (NIF). Beamlet is testing several areas of laser advancements, such as a 37cm Pockels cell, square amplifier, and propagation of a square beam. The diagnostics on beamlet tell the operators how much energy the beam has in different locations, the pulse shape, the energy distribution, and other important information regarding the beam. This information is being used to evaluate new amplifier designs, and extrapolate performance to the NIF laser. In my term at Lawrence Livermore Nationalmore » Laboratory I have designed and built a diagnostic, calibrated instruments used on diagnostics, setup instruments, hooked up communication lines to the instruments, and setup computers to control specific diagnostics.« less

  1. Evaluation of Genotypic and Phenotypic Protease Virulence Tests for Dichelobacter nodosus Infection in Sheep

    PubMed Central

    McPherson, Andrew S.; Dhungyel, Om P.

    2017-01-01

    ABSTRACT Dichelobacter nodosus is a fastidious, strictly anaerobic bacterium, an obligate parasite of the ruminant hoof, and the essential causative agent of virulent ovine footrot. The clinical disease results from a complex interplay between the pathogen, the environment, and the host. Sheep flocks diagnosed with virulent but not benign footrot in Australia may be quarantined and required to undergo a compulsory eradication program, with costs met by the farmer. Virulence of D. nodosus at least partially depends on the elaboration of a protease encoded by aprV2 and manifests as elastase activity. Laboratory virulence tests are used to assist diagnosis because clinical differentiation of virulent and benign footrot can be challenging during the early stages of disease or when the disease is not fully expressed due to unfavorable pasture conditions. Using samples collected from foot lesions from 960 sheep from 40 flocks in four different geographic regions, we evaluated the analytical characteristics of qPCR tests for the protease gene alleles aprV2 and aprB2, and compared these with results from phenotypic protease (elastase and gelatin gel) tests. There was a low level of agreement between clinical diagnosis and quantitative PCR (qPCR) test outcomes at both the flock and sample levels and poor agreement between qPCR test outcomes and the results of phenotypic virulence tests. The diagnostic specificity of the qPCR test was low at both the flock and individual swab levels (31.3% and 18.8%, respectively). By contrast, agreement between the elastase test and clinical diagnosis was high at both the flock level (diagnostic sensitivity [DSe], 100%; diagnostic specificity [DSp], 78.6%) and the isolate level (DSe, 69.5%; DSp, 80.5%). PMID:28202796

  2. Evaluation of Genotypic and Phenotypic Protease Virulence Tests for Dichelobacter nodosus Infection in Sheep.

    PubMed

    McPherson, Andrew S; Dhungyel, Om P; Whittington, Richard J

    2017-05-01

    Dichelobacter nodosus is a fastidious, strictly anaerobic bacterium, an obligate parasite of the ruminant hoof, and the essential causative agent of virulent ovine footrot. The clinical disease results from a complex interplay between the pathogen, the environment, and the host. Sheep flocks diagnosed with virulent but not benign footrot in Australia may be quarantined and required to undergo a compulsory eradication program, with costs met by the farmer. Virulence of D. nodosus at least partially depends on the elaboration of a protease encoded by aprV2 and manifests as elastase activity. Laboratory virulence tests are used to assist diagnosis because clinical differentiation of virulent and benign footrot can be challenging during the early stages of disease or when the disease is not fully expressed due to unfavorable pasture conditions. Using samples collected from foot lesions from 960 sheep from 40 flocks in four different geographic regions, we evaluated the analytical characteristics of qPCR tests for the protease gene alleles aprV2 and aprB2 , and compared these with results from phenotypic protease (elastase and gelatin gel) tests. There was a low level of agreement between clinical diagnosis and quantitative PCR (qPCR) test outcomes at both the flock and sample levels and poor agreement between qPCR test outcomes and the results of phenotypic virulence tests. The diagnostic specificity of the qPCR test was low at both the flock and individual swab levels (31.3% and 18.8%, respectively). By contrast, agreement between the elastase test and clinical diagnosis was high at both the flock level (diagnostic sensitivity [DSe], 100%; diagnostic specificity [DSp], 78.6%) and the isolate level (DSe, 69.5%; DSp, 80.5%). Copyright © 2017 McPherson et al.

  3. Design issues in a randomized controlled trial of a pre-emptive versus empiric antifungal strategy for invasive aspergillosis in patients with high-risk hematologic malignancies.

    PubMed

    Morrissey, C Orla; Chen, Sharon C-A; Sorrell, Tania C; Bradstock, Kenneth F; Szer, Jeffrey; Halliday, Catriona L; Gilroy, Nicole M; Schwarer, Anthony P; Slavin, Monica A

    2011-02-01

    Invasive aspergillosis (IA) is a major cause of mortality in patients with hematological malignancies, due largely to the inability of traditional culture and biopsy methods to make an early or accurate diagnosis. Diagnostic accuracy studies suggest that Aspergillus galactomannan (GM) enzyme immunoassay (ELISA) and Aspergillus PCR-based methods may overcome these limitations, but their impact on patient outcomes should be evaluated in a diagnostic randomized controlled trial (D-RCT). This article describes the methodology of a D-RCT which compares a new pre-emptive strategy (GM-ELISA- and Aspergillus PCR-driven antifungal therapy) with the standard fever-driven empiric antifungal treatment strategy. Issues including primary end-point and patient selection, duration of screening, choice of tests for the pre-emptive strategy, antifungal prophylaxis and bias control, which were considered in the design of the trial, are discussed. We suggest that the template presented herein is considered by researchers when evaluating the utility of new diagnostic tests (ClinicalTrials.gov number, NCT00163722).

  4. Molecular testing for Lynch syndrome in people with colorectal cancer: systematic reviews and economic evaluation.

    PubMed

    Snowsill, Tristan; Coelho, Helen; Huxley, Nicola; Jones-Hughes, Tracey; Briscoe, Simon; Frayling, Ian M; Hyde, Chris

    2017-09-01

    Inherited mutations in deoxyribonucleic acid (DNA) mismatch repair (MMR) genes lead to an increased risk of colorectal cancer (CRC), gynaecological cancers and other cancers, known as Lynch syndrome (LS). Risk-reducing interventions can be offered to individuals with known LS-causing mutations. The mutations can be identified by comprehensive testing of the MMR genes, but this would be prohibitively expensive in the general population. Tumour-based tests - microsatellite instability (MSI) and MMR immunohistochemistry (IHC) - are used in CRC patients to identify individuals at high risk of LS for genetic testing. MLH1 (MutL homologue 1) promoter methylation and BRAF V600E testing can be conducted on tumour material to rule out certain sporadic cancers. To investigate whether testing for LS in CRC patients using MSI or IHC (with or without MLH1 promoter methylation testing and BRAF V600E testing) is clinically effective (in terms of identifying Lynch syndrome and improving outcomes for patients) and represents a cost-effective use of NHS resources. Systematic reviews were conducted of the published literature on diagnostic test accuracy studies of MSI and/or IHC testing for LS, end-to-end studies of screening for LS in CRC patients and economic evaluations of screening for LS in CRC patients. A model-based economic evaluation was conducted to extrapolate long-term outcomes from the results of the diagnostic test accuracy review. The model was extended from a model previously developed by the authors. Ten studies were identified that evaluated the diagnostic test accuracy of MSI and/or IHC testing for identifying LS in CRC patients. For MSI testing, sensitivity ranged from 66.7% to 100.0% and specificity ranged from 61.1% to 92.5%. For IHC, sensitivity ranged from 80.8% to 100.0% and specificity ranged from 80.5% to 91.9%. When tumours showing low levels of MSI were treated as a positive result, the sensitivity of MSI testing increased but specificity fell. No end-to-end studies of screening for LS in CRC patients were identified. Nine economic evaluations of screening for LS in CRC were identified. None of the included studies fully matched the decision problem and hence a new economic evaluation was required. The base-case results in the economic evaluation suggest that screening for LS in CRC patients using IHC, BRAF V600E and MLH1 promoter methylation testing would be cost-effective at a threshold of £20,000 per quality-adjusted life-year (QALY). The incremental cost-effectiveness ratio for this strategy was £11,008 per QALY compared with no screening. Screening without tumour tests is not predicted to be cost-effective. Most of the diagnostic test accuracy studies identified were rated as having a risk of bias or were conducted in unrepresentative samples. There was no direct evidence that screening improves long-term outcomes. No probabilistic sensitivity analysis was conducted. Systematic review evidence suggests that MSI- and IHC-based testing can be used to identify LS in CRC patients, although there was heterogeneity in the methods used in the studies identified and the results of the studies. There was no high-quality empirical evidence that screening improves long-term outcomes and so an evidence linkage approach using modelling was necessary. Key determinants of whether or not screening is cost-effective are the accuracy of tumour-based tests, CRC risk without surveillance, the number of relatives identified for cascade testing, colonoscopic surveillance effectiveness and the acceptance of genetic testing. Future work should investigate screening for more causes of hereditary CRC and screening for LS in endometrial cancer patients. This study is registered as PROSPERO CRD42016033879. The National Institute for Health Research Health Technology Assessment programme.

  5. The after breakfast 50-g, 1-hour glucose challenge test in urban Mexican pregnant women: its sensitivity and specificity evaluated by three diagnostic criteria for gestational diabetes mellitus.

    PubMed

    Espinosa de los Monteros, A; Parra, A; Hidalgo, R; Zambrana, M

    1999-04-01

    To study the sensitivity and specificity of the 50-g, 1-hour gestational glucose challenge test performed 1 to 2 hours after a non-standardized home breakfast in urban Mexican women by using three different gestational diabetes mellitus diagnostic criteria. Four hundred and forty-five consecutive women of 24-28 weeks gestation were studied. The glucose challenge test was performed in the fed state and a week later a fasting 100-g, 3-hours oral glucose tolerance test was carried out in all of them. Duplicate serum glucose concentrations were determined by a glucose-oxidase method. Sensitivity and specificity were calculated using three different diagnostic criteria for gestational diabetes mellitus. The glucose challenge test performed as indicated, with a cutoff of 7.8 mmol/L, had 88-89% sensitivity and 85-87% specificity when using as diagnostic criteria those proposed by the National Diabetes Data Group and by Carpenter & Coustan; by using Sacks et al. criteria, the values were 82% and 88%, respectively. Considering only pregnant women > or = 25 years of age, the sensitivity increased to 92% with the National Diabetes Data Group criteria. Pregnant women < 25 years of age had significantly lower blood glucose values than those with age > or = 25 years during the glucose tolerance test. For the general group the sensitivity of the glucose challenge test performed 1 to 2 hours after breakfast was similar, based on the National Diabetes Data Group and the Carpenter & Coustan's diagnostic criteria for gestational diabetes mellitus. However, when pregnant women > or = 25 years of age were considered, the use of the former criteria yielded a slightly better sensitivity.

  6. Evaluation of an Intelligent Tutoring System in Pathology: Effects of External Representation on Performance Gains, Metacognition, and Acceptance

    PubMed Central

    Crowley, Rebecca S.; Legowski, Elizabeth; Medvedeva, Olga; Tseytlin, Eugene; Roh, Ellen; Jukic, Drazen

    2007-01-01

    Objective Determine effects of computer-based tutoring on diagnostic performance gains, meta-cognition, and acceptance using two different problem representations. Describe impact of tutoring on spectrum of diagnostic skills required for task performance. Identify key features of student-tutor interaction contributing to learning gains. Design Prospective, between-subjects study, controlled for participant level of training. Resident physicians in two academic pathology programs spent four hours using one of two interfaces which differed mainly in external problem representation. The case-focused representation provided an open-learning environment in which students were free to explore evidence-hypothesis relationships within a case, but could not visualize the entire diagnostic space. The knowledge-focused representation provided an interactive representation of the entire diagnostic space, which more tightly constrained student actions. Measurements Metrics included results of pretest, post-test and retention-test for multiple choice and case diagnosis tests, ratios of performance to student reported certainty, results of participant survey, learning curves, and interaction behaviors during tutoring. Results Students had highly significant learning gains after one tutoring session. Learning was retained at one week. There were no differences between the two interfaces in learning gains on post-test or retention test. Only students in the knowledge-focused interface exhibited significant metacognitive gains from pretest to post-test and pretest to retention test. Students rated the knowledge-focused interface significantly higher than the case-focused interface. Conclusions Cognitive tutoring is associated with improved diagnostic performance in a complex medical domain. The effect is retained at one-week post-training. Knowledge-focused external problem representation shows an advantage over case-focused representation for metacognitive effects and user acceptance. PMID:17213494

  7. Evaluation of an intelligent tutoring system in pathology: effects of external representation on performance gains, metacognition, and acceptance.

    PubMed

    Crowley, Rebecca S; Legowski, Elizabeth; Medvedeva, Olga; Tseytlin, Eugene; Roh, Ellen; Jukic, Drazen

    2007-01-01

    Determine effects of computer-based tutoring on diagnostic performance gains, meta-cognition, and acceptance using two different problem representations. Describe impact of tutoring on spectrum of diagnostic skills required for task performance. Identify key features of student-tutor interaction contributing to learning gains. Prospective, between-subjects study, controlled for participant level of training. Resident physicians in two academic pathology programs spent four hours using one of two interfaces which differed mainly in external problem representation. The case-focused representation provided an open-learning environment in which students were free to explore evidence-hypothesis relationships within a case, but could not visualize the entire diagnostic space. The knowledge-focused representation provided an interactive representation of the entire diagnostic space, which more tightly constrained student actions. Metrics included results of pretest, post-test and retention-test for multiple choice and case diagnosis tests, ratios of performance to student reported certainty, results of participant survey, learning curves, and interaction behaviors during tutoring. Students had highly significant learning gains after one tutoring session. Learning was retained at one week. There were no differences between the two interfaces in learning gains on post-test or retention test. Only students in the knowledge-focused interface exhibited significant metacognitive gains from pretest to post-test and pretest to retention test. Students rated the knowledge-focused interface significantly higher than the case-focused interface. Cognitive tutoring is associated with improved diagnostic performance in a complex medical domain. The effect is retained at one-week post-training. Knowledge-focused external problem representation shows an advantage over case-focused representation for metacognitive effects and user acceptance.

  8. A prospective evaluation of whole-exome sequencing as a first-tier molecular test in infants with suspected monogenic disorders.

    PubMed

    Stark, Zornitza; Tan, Tiong Y; Chong, Belinda; Brett, Gemma R; Yap, Patrick; Walsh, Maie; Yeung, Alison; Peters, Heidi; Mordaunt, Dylan; Cowie, Shannon; Amor, David J; Savarirayan, Ravi; McGillivray, George; Downie, Lilian; Ekert, Paul G; Theda, Christiane; James, Paul A; Yaplito-Lee, Joy; Ryan, Monique M; Leventer, Richard J; Creed, Emma; Macciocca, Ivan; Bell, Katrina M; Oshlack, Alicia; Sadedin, Simon; Georgeson, Peter; Anderson, Charlotte; Thorne, Natalie; Melbourne Genomics Health Alliance; Gaff, Clara; White, Susan M

    2016-11-01

    To prospectively evaluate the diagnostic and clinical utility of singleton whole-exome sequencing (WES) as a first-tier test in infants with suspected monogenic disease. Singleton WES was performed as a first-tier sequencing test in infants recruited from a single pediatric tertiary center. This occurred in parallel with standard investigations, including single- or multigene panel sequencing when clinically indicated. The diagnosis rate, clinical utility, and impact on management of singleton WES were evaluated. Of 80 enrolled infants, 46 received a molecular genetic diagnosis through singleton WES (57.5%) compared with 11 (13.75%) who underwent standard investigations in the same patient group. Clinical management changed following exome diagnosis in 15 of 46 diagnosed participants (32.6%). Twelve relatives received a genetic diagnosis following cascade testing, and 28 couples were identified as being at high risk of recurrence in future pregnancies. This prospective study provides strong evidence for increased diagnostic and clinical utility of singleton WES as a first-tier sequencing test for infants with a suspected monogenic disorder. Singleton WES outperformed standard care in terms of diagnosis rate and the benefits of a diagnosis, namely, impact on management of the child and clarification of reproductive risks for the extended family in a timely manner.Genet Med 18 11, 1090-1096.

  9. Evaluation of Coronary Artery Stenosis by Quantitative Flow Ratio During Invasive Coronary Angiography: The WIFI II Study (Wire-Free Functional Imaging II).

    PubMed

    Westra, Jelmer; Tu, Shengxian; Winther, Simon; Nissen, Louise; Vestergaard, Mai-Britt; Andersen, Birgitte Krogsgaard; Holck, Emil Nielsen; Fox Maule, Camilla; Johansen, Jane Kirk; Andreasen, Lene Nyhus; Simonsen, Jo Krogsgaard; Zhang, Yimin; Kristensen, Steen Dalby; Maeng, Michael; Kaltoft, Anne; Terkelsen, Christian Juhl; Krusell, Lars Romer; Jakobsen, Lars; Reiber, Johan H C; Lassen, Jens Flensted; Bøttcher, Morten; Bøtker, Hans Erik; Christiansen, Evald Høj; Holm, Niels Ramsing

    2018-03-01

    Quantitative flow ratio (QFR) is a novel diagnostic modality for functional testing of coronary artery stenosis without the use of pressure wires and induction of hyperemia. QFR is based on computation of standard invasive coronary angiographic imaging. The purpose of WIFI II (Wire-Free Functional Imaging II) was to evaluate the feasibility and diagnostic performance of QFR in unselected consecutive patients. WIFI II was a predefined substudy to the Dan-NICAD study (Danish Study of Non-Invasive Diagnostic Testing in Coronary Artery Disease), referring 362 consecutive patients with suspected coronary artery disease on coronary computed tomographic angiography for diagnostic invasive coronary angiography. Fractional flow reserve (FFR) was measured in all segments with 30% to 90% diameter stenosis. Blinded observers calculated QFR (Medis Medical Imaging bv, The Netherlands) for comparison with FFR. FFR was measured in 292 lesions from 191 patients. Ten (5%) and 9 patients (5%) were excluded because of FFR and angiographic core laboratory criteria, respectively. QFR was successfully computed in 240 out of 255 lesions (94%) with a mean diameter stenosis of 50±12%. Mean difference between FFR and QFR was 0.01±0.08. QFR correctly classified 83% of the lesions using FFR with cutoff at 0.80 as reference standard. The area under the receiver operating characteristic curve was 0.86 (95% confidence interval, 0.81-0.91) with a sensitivity, specificity, negative predictive value, and positive predictive value of 77%, 86%, 75%, and 87%, respectively. A QFR-FFR hybrid approach based on the present results enables wire-free and adenosine-free procedures in 68% of cases. Functional lesion evaluation by QFR assessment showed good agreement and diagnostic accuracy compared with FFR. Studies comparing clinical outcome after QFR- and FFR-based diagnostic strategies are required. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02264717. © 2018 The Authors.

  10. Yield and cost of individual common diagnostic tests in new primary care outpatients in Japan.

    PubMed

    Takemura, Yuzuru; Ishida, Haku; Inoue, Yuji; Beck, J Robert

    2002-01-01

    Appropriate diagnostic testing involves considerations of cost-effectiveness. We examined the cost-effectiveness of individual tests in a panel of tests defined by the Japan Society of Clinical Pathology. We studied 540 new, symptomatic primary care outpatients with a set of 30 common diagnostic tests [the Essential Laboratory Tests (2); ELT(2) panel] for clinical evaluation and identification of occult disease. A useful result (UR) of testing was defined as a finding that contributed to a change in a physician's diagnosis or decision-making relating to a "tentative initial diagnosis" obtained from history and physical examination alone. The ELT(2) panel testing yielded 398 URs and uncovered 261 occult diseases among 540 patients. In total, 1592 tests contributed to either UR-generation or discovery of occult disease. The cost per effective test (cost required per test that contributed to either definition of effectiveness) ranged from 108 yen (approximately 0.92 US dollars) for total cholesterol to 6200 yen (approximately 52.50 dollars) for chest x-ray. Contribution rates and the cost per effective test varied among disease categories. We restructured panel components considering the effectiveness of each test. Subsets of the ELT(2) would have improved cost-effectiveness and achieved cost savings in five of eight disease categories. Assembly of tests based on cost-effectiveness can improve clinical efficiency and decrease total cost of panel testing for selected patient groups.

  11. Limitations of Rapid Diagnostic Testing in Patients with Suspected Malaria: A Diagnostic Accuracy Evaluation from Swaziland, a Low-Endemicity Country Aiming for Malaria Elimination

    PubMed Central

    Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan

    2017-01-01

    Abstract Background. The performance of Plasmodium falciparum–specific histidine-rich protein 2–based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Methods. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2–based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. Results. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. Conclusions. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. PMID:28369268

  12. Limitations of Rapid Diagnostic Testing in Patients with Suspected Malaria: A Diagnostic Accuracy Evaluation from Swaziland, a Low-Endemicity Country Aiming for Malaria Elimination.

    PubMed

    Ranadive, Nikhil; Kunene, Simon; Darteh, Sarah; Ntshalintshali, Nyasatu; Nhlabathi, Nomcebo; Dlamini, Nomcebo; Chitundu, Stanley; Saini, Manik; Murphy, Maxwell; Soble, Adam; Schwartz, Alanna; Greenhouse, Bryan; Hsiang, Michelle S

    2017-05-01

    The performance of Plasmodium falciparum-specific histidine-rich protein 2-based rapid diagnostic tests (RDTs) to evaluate suspected malaria in low-endemicity settings has not been well characterized. Using dried blood spot samples from patients with suspected malaria at 37 health facilities from 2012 to 2014 in the low-endemicity country of Swaziland, we investigated the diagnostic accuracy of histidine-rich protein 2-based RDTs using qualitative polymerase chain reaction (PCR) (nested PCR targeting the cytochrome b gene) and quantitative PCR as reference standards. To explore reasons for false-negative and/or false-positive results, we used pfhrp2/3-specific PCR and logistic regression analyses of potentially associated epidemiological factors. From 1353 patients, 93.0% of RDT-positive (n = 185) and 31.2% of RDT-negative samples (n = 340) were available and selected for testing. Compared with nested PCR, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of RDTs were 51.7%, 94.1%, 67.3%, and 89.1%, respectively. After exclusion of samples with parasite densities <100/μL, which accounted for 75.7% of false-negative results and 33.3% of PCR-detectable infections, the sensitivity, specificity, PPV, and NPV were 78.8%, 93.7%, 62.3%, and 97.1%. Deletions of pfhrp2 were not detected. False-positivity was more likely during the second year and was not associated with demographics, recent malaria, health facility testing characteristics, or potential DNA degradation. In the low-transmission setting of Swaziland, we demonstrated low sensitivity of RDT for malaria diagnosis, owing to an unexpectedly high proportion of low-density infection among symptomatic subjects. The PPV was also low, requiring further investigation. A more accurate point-of-care diagnostic may be needed to support malaria elimination efforts. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  13. Evaluation of the diagnostic accuracy of CareStart G6PD deficiency Rapid Diagnostic Test (RDT) in a malaria endemic area in Ghana, Africa.

    PubMed

    Adu-Gyasi, Dennis; Asante, Kwaku Poku; Newton, Sam; Dosoo, David; Amoako, Sabastina; Adjei, George; Amoako, Nicholas; Ankrah, Love; Tchum, Samuel Kofi; Mahama, Emmanuel; Agyemang, Veronica; Kayan, Kingsley; Owusu-Agyei, Seth

    2015-01-01

    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most widespread enzyme defect that can result in red cell breakdown under oxidative stress when exposed to certain medicines including antimalarials. We evaluated the diagnostic accuracy of CareStart G6PD deficiency Rapid Diagnostic Test (RDT) as a point-of-care tool for screening G6PD deficiency. A cross-sectional study was conducted among 206 randomly selected and consented participants from a group with known G6PD deficiency status between February 2013 and June 2013. A maximum of 1.6ml of capillary blood samples were used for G6PD deficiency screening using CareStart G6PD RDT and Trinity qualitative with Trinity quantitative methods as the "gold standard". Samples were also screened for the presence of malaria parasites. Data entry and analysis were done using Microsoft Access 2010 and Stata Software version 12. Kintampo Health Research Centre Institutional Ethics Committee granted ethical approval. The sensitivity (SE) and specificity (SP) of CareStart G6PD deficiency RDT was 100% and 72.1% compared to Trinity quantitative method respectively and was 98.9% and 96.2% compared to Trinity qualitative method. Malaria infection status had no significant (P=0.199) change on the performance of the G6PD RDT test kit compared to the "gold standard". The outcome of this study suggests that the diagnostic performance of the CareStart G6PD deficiency RDT kit was high and it is acceptable at determining the G6PD deficiency status in a high malaria endemic area in Ghana. The RDT kit presents as an attractive tool for point-of-care G6PD deficiency for rapid testing in areas with high temperatures and less expertise. The CareStart G6PD deficiency RDT kit could be used to screen malaria patients before administration of the fixed dose primaquine with artemisinin-based combination therapy.

  14. ACCURACY OF PLASMA FREE METANEPHRINES IN THE DIAGNOSIS OF PHEOCHROMOCYTOMA AND PARAGANGLIOMA: A SYSTEMATIC REVIEW AND META-ANALYSIS.

    PubMed

    Chen, Yan; Xiao, Huangmeng; Zhou, Xieda; Huang, Xiaoyu; Li, Yanbing; Xiao, Haipeng; Cao, Xiaopei

    2017-10-01

    Various studies have validated plasma free metanephrines (MNs) as biomarkers for pheochromocytoma and paraganglioma (PPGL). This meta-analysis aimed to estimate the overall diagnostic accuracy of this biochemical test for PPGL. We searched the PubMed, the Cochrane Library, Web of Science, Embase, Scopus, OvidSP, and ProQuest Dissertations & Theses databases from January 1, 1995 to December 2, 2016 and selected studies written in English that assessed plasma free MNs in the diagnosis of PPGL. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate the quality of the included studies. We calculated pooled sensitivities, specificities, positive and negative likelihood ratios, diagnostic odds ratios (DORs) and areas under curve (AUCs) with their 95% confidence intervals (95% CIs). Heterogeneity was assessed by I 2 . To identify the source of heterogeneity, we evaluated the threshold effect and performed a meta-regression. Deeks' funnel plot was selected for investigating any potential publication bias. Although the combination of metanephrine (MN) and normetanephrine (NMN) carried lower specificity (0.94, 95% CI 0.90-0.97) than NMN (0.97, 95% CI 0.92-0.99), NMN was generally more accurate than individual tests, with the highest AUC (0.99, 95% CI 0.97-0.99), DOR (443.35, 95% CI 216.9-906.23), and pooled sensitivity (0.97, 95% CI 0.94-0.98) values. Threshold effect and meta-regression analyses showed that different cut-offs, blood sampling positions, study types and test methods contributed to heterogeneity. This meta-analysis suggested an effective value for combined plasma free MNs for the diagnosis of PPGL, but testing for MNs requires more standardization using tightly regulated studies. AUC = area under curve; CI = confidence interval; DOR = diagnostic odds ratio; EIA = enzyme immunoassay; LC-ECD = liquid chromatography-electrochemical detection; LC-MS/MS = liquid chromatography-tandem mass spectrometry; MN = metanephrine; NMN = normetaneprhine; PPGL = pheochromocytoma and paraganglioma; QUADAS-2 = Quality Assessment of Diagnostic Accuracy Studies 2.

  15. Fecal immunochemical test for predicting mucosal healing in ulcerative colitis patients: A systematic review and meta-analysis.

    PubMed

    Dai, Cong; Jiang, Min; Sun, Ming-Jun; Cao, Qin

    2018-05-01

    Fecal immunochemical test (FIT) is a promising marker for assessment of inflammatory bowel disease activity. However, the utility of FIT for predicting mucosal healing (MH) of ulcerative colitis (UC) patients has yet to be clearly demonstrated. The objective of our study was to perform a diagnostic test accuracy test meta-analysis evaluating the diagnostic accuracy of FIT in predicting MH of UC patients. We systematically searched the databases from inception to November 2017 that evaluated MH in UC. The methodological quality of each study was assessed according to the Quality Assessment of Diagnostic Accuracy Studies checklist. The extracted data were pooled using a summary receiver operating characteristic curve model. Random-effects model was used to summarize the diagnostic odds ratio, sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Six studies comprising 625 UC patients were included in the meta-analysis. The pooled sensitivity and specificity values for predicting MH in UC were 0.77 (95% confidence interval [CI], 0.72-0.81) and 0.81 (95% CI, 0.76-0.85), respectively. The FIT level had a high rule-in value (positive likelihood ratio, 3.79; 95% CI, 2.85-5.03) and a moderate rule-out value (negative likelihood ratio, 0.26; 95% CI, 0.16-0.43) for predicting MH in UC. The results of the receiver operating characteristic curve analysis (area under the curve, 0.88; standard error of the mean, 0.02) and diagnostic odds ratio (18.08; 95% CI, 9.57-34.13) also revealed improved discrimination for identifying MH in UC with FIT concentration. Our meta-analysis has found that FIT is a simple, reliable non-invasive marker for predicting MH in UC patients. © 2018 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  16. "Eyeball test" of thermographic patterns for predicting a successful lateral infraclavicular block.

    PubMed

    Andreasen, Asger M; Linnet, Karen E; Asghar, Semera; Rothe, Christian; Rosenstock, Charlotte V; Lange, Kai H W; Lundstrøm, Lars H

    2017-11-01

    Increased distal skin temperature can be used to predict the success of lateral infraclavicular (LIC) block. We hypothesized that an "eyeball test" of specific infrared thermographic patterns after LIC block could be used to determine block success. In this observational study, five observers trained in four distinct thermographic patterns independently evaluated thermographic images of the hands of 40 patients at baseline and at one-minute intervals for 30 min after a LIC block. Sensitivity, specificity, and predictive values of a positive and a negative test were estimated to evaluate the validity of specific thermographic patterns for predicting a successful block. Sensory and motor block of the musculocutaneous, radial, ulnar, and median nerves defined block success. Fleiss' kappa statistics of multiple interobserver agreements were used to evaluate reliability. As a diagnostic test, the defined specific thermographic patterns of the hand predicted a successful block with increasing accuracy over the 30-min observation period. Block success was predicted with a sensitivity of 92.4% (95% confidence interval [CI], 86.8 to 96.2) and with a specificity of 84.0% (95% CI, 70.3 to 92.4) at min 30. The Fleiss' kappa for the five observers was 0.87 (95% CI, 0.77 to 0.96). We conclude that visual evaluation by an eyeball test of specific thermographic patterns of the blocked hands may be useful as a valid and reliable diagnostic test for predicting a successful LIC block.

  17. Determining the Optimal Number of Core Needle Biopsy Passes for Molecular Diagnostics.

    PubMed

    Hoang, Nam S; Ge, Benjamin H; Pan, Lorraine Y; Ozawa, Michael G; Kong, Christina S; Louie, John D; Shah, Rajesh P

    2018-03-01

    The number of core biopsy passes required for adequate next-generation sequencing is impacted by needle cut, needle gauge, and the type of tissue involved. This study evaluates diagnostic adequacy of core needle lung biopsies based on number of passes and provides guidelines for other tissues based on simulated biopsies in ex vivo porcine organ tissues. The rate of diagnostic adequacy for pathology and molecular testing from lung biopsy procedures was measured for eight operators pre-implementation (September 2012-October 2013) and post-implementation (December 2013-April 2014) of a standard protocol using 20-gauge side-cut needles for ten core biopsy passes at a single academic hospital. Biopsy pass volume was then estimated in ex vivo porcine muscle, liver, and kidney using side-cut devices at 16, 18, and 20 gauge and end-cut devices at 16 and 18 gauge to estimate minimum number of passes required for adequate molecular testing. Molecular diagnostic adequacy increased from 69% (pre-implementation period) to 92% (post-implementation period) (p < 0.001) for lung biopsies. In porcine models, both 16-gauge end-cut and side-cut devices require one pass to reach the validated volume threshold to ensure 99% adequacy for molecular characterization, while 18- and 20-gauge devices require 2-5 passes depending on needle cut and tissue type. Use of 20-gauge side-cut core biopsy needles requires a significant number of passes to ensure diagnostic adequacy for molecular testing across all tissue types. To ensure diagnostic adequacy for molecular testing, 16- and 18-gauge needles require markedly fewer passes.

  18. Comparison of Biotinylated Monoclonal and Polyclonal Antibodies in an Evaluation of a Direct Rapid Immunohistochemical Test for the Routine Diagnosis of Rabies in Southern Africa

    PubMed Central

    Coetzer, Andre; Sabeta, Claude T.; Markotter, Wanda; Rupprecht, Charles E.; Nel, Louis H.

    2014-01-01

    The major etiological agent of rabies, rabies virus (RABV), accounts for tens of thousands of human deaths per annum. The majority of these deaths are associated with rabies cycles in dogs in resource-limited countries of Africa and Asia. Although routine rabies diagnosis plays an integral role in disease surveillance and management, the application of the currently recommended direct fluorescent antibody (DFA) test in countries on the African and Asian continents remains quite limited. A novel diagnostic assay, the direct rapid immunohistochemical test (dRIT), has been reported to have a diagnostic sensitivity and specificity equal to that of the DFA test while offering advantages in cost, time and interpretation. Prior studies used the dRIT utilized monoclonal antibody (MAb) cocktails. The objective of this study was to test the hypothesis that a biotinylated polyclonal antibody (PAb) preparation, applied in the dRIT protocol, would yield equal or improved results compared to the use of dRIT with MAbs. We also wanted to compare the PAb dRIT with the DFA test, utilizing the same PAb preparation with a fluorescent label. The PAb dRIT had a diagnostic sensitivity and specificity of 100%, which was shown to be marginally higher than the diagnostic efficacy observed for the PAb DFA test. The classical dRIT, relying on two-biotinylated MAbs, was applied to the same panel of samples and a reduced diagnostic sensitivity (83.50% and 90.78% respectively) was observed. Antigenic typing of the false negative samples indicated all of these to be mongoose RABV variants. Our results provided evidence that a dRIT with alternative antibody preparations, conjugated to a biotin moiety, has a diagnostic efficacy equal to that of a DFA relying on the same antibody and that the antibody preparation should be optimized for virus variants specific to the geographical area of focus. PMID:25254652

  19. Comparison of biotinylated monoclonal and polyclonal antibodies in an evaluation of a direct rapid immunohistochemical test for the routine diagnosis of rabies in southern Africa.

    PubMed

    Coetzer, Andre; Sabeta, Claude T; Markotter, Wanda; Rupprecht, Charles E; Nel, Louis H

    2014-09-01

    The major etiological agent of rabies, rabies virus (RABV), accounts for tens of thousands of human deaths per annum. The majority of these deaths are associated with rabies cycles in dogs in resource-limited countries of Africa and Asia. Although routine rabies diagnosis plays an integral role in disease surveillance and management, the application of the currently recommended direct fluorescent antibody (DFA) test in countries on the African and Asian continents remains quite limited. A novel diagnostic assay, the direct rapid immunohistochemical test (dRIT), has been reported to have a diagnostic sensitivity and specificity equal to that of the DFA test while offering advantages in cost, time and interpretation. Prior studies used the dRIT utilized monoclonal antibody (MAb) cocktails. The objective of this study was to test the hypothesis that a biotinylated polyclonal antibody (PAb) preparation, applied in the dRIT protocol, would yield equal or improved results compared to the use of dRIT with MAbs. We also wanted to compare the PAb dRIT with the DFA test, utilizing the same PAb preparation with a fluorescent label. The PAb dRIT had a diagnostic sensitivity and specificity of 100%, which was shown to be marginally higher than the diagnostic efficacy observed for the PAb DFA test. The classical dRIT, relying on two-biotinylated MAbs, was applied to the same panel of samples and a reduced diagnostic sensitivity (83.50% and 90.78% respectively) was observed. Antigenic typing of the false negative samples indicated all of these to be mongoose RABV variants. Our results provided evidence that a dRIT with alternative antibody preparations, conjugated to a biotin moiety, has a diagnostic efficacy equal to that of a DFA relying on the same antibody and that the antibody preparation should be optimized for virus variants specific to the geographical area of focus.

  20. Validity of Combining History Elements and Physical Examination Tests to Diagnose Patellofemoral Pain.

    PubMed

    Décary, Simon; Frémont, Pierre; Pelletier, Bruno; Fallaha, Michel; Belzile, Sylvain; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Feldman, Debbie; Sylvestre, Marie-Pierre; Vendittoli, Pascal-André; Desmeules, François

    2018-04-01

    To assess the validity of diagnostic clusters combining history elements and physical examination tests to diagnose or exclude patellofemoral pain (PFP). Prospective diagnostic study. Orthopedic outpatient clinics, family medicine clinics, and community-dwelling. Consecutive patients (N=279) consulting one of the participating orthopedic surgeons (n=3) or sport medicine physicians (n=2) for any knee complaint. Not applicable. History elements and physical examination tests were obtained by a trained physiotherapist blinded to the reference standard: a composite diagnosis including both physical examination tests and imaging results interpretation performed by an expert physician. Penalized logistic regression (least absolute shrinkage and selection operator) was used to identify history elements and physical examination tests associated with the diagnosis of PFP, and recursive partitioning was used to develop diagnostic clusters. Diagnostic accuracy measures including sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios with associated 95% confidence intervals (CIs) were calculated. Two hundred seventy-nine participants were evaluated, and 75 had a diagnosis of PFP (26.9%). Different combinations of history elements and physical examination tests including the age of participants, knee pain location, difficulty descending stairs, patellar facet palpation, and passive knee extension range of motion were associated with a diagnosis of PFP and used in clusters to accurately discriminate between individuals with PFP and individuals without PFP. Two diagnostic clusters developed to confirm the presence of PFP yielded a positive likelihood ratio of 8.7 (95% CI, 5.2-14.6) and 3 clusters to exclude PFP yielded a negative likelihood ratio of .12 (95% CI, .06-.27). Diagnostic clusters combining common history elements and physical examination tests that can accurately diagnose or exclude PFP compared to various knee disorders were developed. External validation is required before clinical use. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  1. Molecular Testing for miRNA, mRNA, and DNA on Fine-Needle Aspiration Improves the Preoperative Diagnosis of Thyroid Nodules With Indeterminate Cytology.

    PubMed

    Labourier, Emmanuel; Shifrin, Alexander; Busseniers, Anne E; Lupo, Mark A; Manganelli, Monique L; Andruss, Bernard; Wylie, Dennis; Beaudenon-Huibregtse, Sylvie

    2015-07-01

    Molecular testing for oncogenic mutations or gene expression in fine-needle aspirations (FNAs) from thyroid nodules with indeterminate cytology identifies a subset of benign or malignant lesions with high predictive value. This study aimed to evaluate a novel diagnostic algorithm combining mutation detection and miRNA expression to improve the diagnostic yield of molecular cytology. Surgical specimens and preoperative FNAs (n = 638) were tested for 17 validated gene alterations using the miRInform Thyroid test and with a 10-miRNA gene expression classifier generating positive (malignant) or negative (benign) results. Cross-sectional sampling of thyroid nodules with atypia of undetermined significance/follicular lesion of undetermined significance (AUS/FLUS) or follicular neoplasm/suspicious for a follicular neoplasm (FN/SFN) cytology (n = 109) was conducted at 12 endocrinology centers across the United States. Qualitative molecular results were compared with surgical histopathology to determine diagnostic performance and model clinical effect. Mutations were detected in 69% of nodules with malignant outcome. Among mutation-negative specimens, miRNA testing correctly identified 64% of malignant cases and 98% of benign cases. The diagnostic sensitivity and specificity of the combined algorithm was 89% (95% confidence interval [CI], 73-97%) and 85% (95% CI, 75-92%), respectively. At 32% cancer prevalence, 61% of the molecular results were benign with a negative predictive value of 94% (95% CI, 85-98%). Independently of variations in cancer prevalence, the test increased the yield of true benign results by 65% relative to mRNA-based gene expression classification and decreased the rate of avoidable diagnostic surgeries by 69%. Multiplatform testing for DNA, mRNA, and miRNA can accurately classify benign and malignant thyroid nodules, increase the diagnostic yield of molecular cytology, and further improve the preoperative risk-based management of benign nodules with AUS/FLUS or FN/SFN cytology.

  2. Special physical examination tests for superior labrum anterior-posterior shoulder tears: an examination of clinical usefulness.

    PubMed

    Sandrey, Michelle A

    2013-01-01

    Calvert E, Chambers GK, Regan W, Hawkins RH, Leith JM. Special physical examination tests for superior labrum anterior-posterior shoulder injuries are clinically limited and invalid: a diagnostic systematic review. J Clin Epidemiol. 2009;62(5):558-563. The systematic review focused on diagnostic accuracy studies to determine if evidence was sufficient to support the use of superior labrum anterior-posterior (SLAP) physical examination tests as valid and reliable. The primary question was whether there was sufficient evidence in the published literature to support the use of SLAP physical examination tests as valid and reliable diagnostic test procedures. Studies published in English were identified through database searches on MEDLINE, EMBASE, and the Cochrane database (1970-2004) using the search term SLAP lesions. The medical subject headings of arthroscopy, shoulder joint, and athletic injuries were combined with test or testing, physical examination, and sensitivity and specificity to locate additional sources. Other sources were identified by rereviewing the reference lists of included studies and review articles. Studies were eligible based on the following criteria: (1) published in English, (2) focused on the physical examination of SLAP lesions, and (3) presented original data. A study was excluded if the article was limited to a clinical description of 1 or more special tests without any research focus to provide clinical accuracy data or if it did not focus on the topic. The abstracts that were located through the search strategies were reviewed, and potentially relevant abstracts were selected. Strict epidemiologic methods were used to obtain and collate all relevant studies; the authors developed a study questionnaire to record study name, year of publication, study design, sample size, and statistics. Validity of the diagnostic test study was determined by applying the 5 criteria proposed by Calvert et al. If the study met the inclusion and validity criteria, 95% confidence intervals were calculated for each sensitivity, specificity, and positive and negative likelihood ratio reported. No specific information was provided about the procedure if the reviewers disagreed on how the evaluation criteria were applied. The specific search criteria led to the identification of 29 full-text articles. The studies were reviewed, and inclusion and exclusion criteria were applied. This resulted in 14 excluded studies and 15 eligible studies for analysis. Of the 15 eligible studies, 1 evaluated only a single physical examination test for a SLAP lesion or biceps tendon injury, and 10 studies evaluated 2 to 6 physical examination tests for a SLAP lesion or biceps tendon injury. Nine studies reported sensitivities and specificities greater than 75%, 4 had sensitivities less than 75%, 3 had specificities less than 75%, 1 did not report sensitivity, and 2 did not report specificities. When validity was assessed for those 15 papers, only 1 study that evaluated the biceps tendon met the 5 critical appraisal criteria of Calvert et al and calculated 95% confidence intervals. When the Speed and Yergason tests were each compared with the gold standard (arthroscopy), the confidence intervals for the positive and negative likelihood ratios spanned 1. This indicated that the test result is unlikely to change the odds of having or not having the condition, respectively. The literature currently used as a reference for teaching in medical schools and continuing education lacks the necessary validity to help rule in or out a SLAP lesion or biceps tendon involvement. Based on the results from the systematic review conducted by Calvert et al, no tests clinically diagnose a SLAP lesion. This is a cause for concern as magnetic resonance imaging or magnetic resonance arthrography, which are frequently used to assess a possible SLAP lesion, may also have diagnostic flaws and may be cost prohibitive. Performing arthroscopy on every patient to rule the condition in or out is unethical, especially if a SLAP lesion is not present. More rigorous validity studies should be conducted for SLAP lesion physical examination tests using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool or Standards for Reporting Diagnostic Accuracy (STARD) criteria.

  3. Special Physical Examination Tests for Superior Labrum Anterior-Posterior Shoulder Tears: An Examination of Clinical Usefulness

    PubMed Central

    Sandrey, Michelle A.

    2013-01-01

    Reference/Citation: Calvert E, Chambers GK, Regan W, Hawkins RH, Leith JM. Special physical examination tests for superior labrum anterior-posterior shoulder injuries are clinically limited and invalid: a diagnostic systematic review. J Clin Epidemiol. 2009;62(5):558–563. Clinical Question: The systematic review focused on diagnostic accuracy studies to determine if evidence was sufficient to support the use of superior labrum anterior-posterior (SLAP) physical examination tests as valid and reliable. The primary question was whether there was sufficient evidence in the published literature to support the use of SLAP physical examination tests as valid and reliable diagnostic test procedures. Data Sources: Studies published in English were identified through database searches on MEDLINE, EMBASE, and the Cochrane database (1970–2004) using the search term SLAP lesions. The medical subject headings of arthroscopy, shoulder joint, and athletic injuries were combined with test or testing, physical examination, and sensitivity and specificity to locate additional sources. Other sources were identified by rereviewing the reference lists of included studies and review articles. Study Selection: Studies were eligible based on the following criteria: (1) published in English, (2) focused on the physical examination of SLAP lesions, and (3) presented original data. A study was excluded if the article was limited to a clinical description of 1 or more special tests without any research focus to provide clinical accuracy data or if it did not focus on the topic. Data Extraction: The abstracts that were located through the search strategies were reviewed, and potentially relevant abstracts were selected. Strict epidemiologic methods were used to obtain and collate all relevant studies; the authors developed a study questionnaire to record study name, year of publication, study design, sample size, and statistics. Validity of the diagnostic test study was determined by applying the 5 criteria proposed by Calvert et al. If the study met the inclusion and validity criteria, 95% confidence intervals were calculated for each sensitivity, specificity, and positive and negative likelihood ratio reported. No specific information was provided about the procedure if the reviewers disagreed on how the evaluation criteria were applied. Main Results: The specific search criteria led to the identification of 29 full-text articles. The studies were reviewed, and inclusion and exclusion criteria were applied. This resulted in 14 excluded studies and 15 eligible studies for analysis. Of the 15 eligible studies, 1 evaluated only a single physical examination test for a SLAP lesion or biceps tendon injury, and 10 studies evaluated 2 to 6 physical examination tests for a SLAP lesion or biceps tendon injury. Nine studies reported sensitivities and specificities greater than 75%, 4 had sensitivities less than 75%, 3 had specificities less than 75%, 1 did not report sensitivity, and 2 did not report specificities. When validity was assessed for those 15 papers, only 1 study that evaluated the biceps tendon met the 5 critical appraisal criteria of Calvert et al and calculated 95% confidence intervals. When the Speed and Yergason tests were each compared with the gold standard (arthroscopy), the confidence intervals for the positive and negative likelihood ratios spanned 1. This indicated that the test result is unlikely to change the odds of having or not having the condition, respectively. Conclusions: The literature currently used as a reference for teaching in medical schools and continuing education lacks the necessary validity to help rule in or out a SLAP lesion or biceps tendon involvement. Based on the results from the systematic review conducted by Calvert et al, no tests clinically diagnose a SLAP lesion. This is a cause for concern as magnetic resonance imaging or magnetic resonance arthrography, which are frequently used to assess a possible SLAP lesion, may also have diagnostic flaws and may be cost prohibitive. Performing arthroscopy on every patient to rule the condition in or out is unethical, especially if a SLAP lesion is not present. More rigorous validity studies should be conducted for SLAP lesion physical examination tests using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool or Standards for Reporting Diagnostic Accuracy (STARD) criteria. PMID:23914880

  4. Non-invasive diagnostic assessment tools for the detection of liver fibrosis in patients with suspected alcohol-related liver disease: a systematic review and economic evaluation.

    PubMed

    Stevenson, M; Lloyd-Jones, M; Morgan, M Y; Wong, R

    2012-01-01

    Excessive alcohol consumption may lead to the development of alcohol-related liver disease (ALD). Liver biopsy may be used in patients with suspected ALD to confirm the diagnosis, exclude other or additional liver pathologies, and provide accurate staging of the degree of liver injury in order to enable the prediction of prognosis and inform treatment decisions. However, as it is an invasive procedure that carries the risk of morbidity and mortality, current UK guidance recommends that biopsy is not required to confirm the diagnosis in patients with a high clinical suspicion of ALD in whom blood tests have excluded other causes of liver disease, unless it is necessary to confirm a diagnosis of acute alcoholic hepatitis in order to inform specific treatment decisions. To evaluate the diagnostic accuracy, cost-effectiveness, and effect on patient outcomes of four non-invasive tests for liver fibrosis [the Enhanced Liver Fibrosis (ELF™) test (Siemens Healthcare Diagnostic Inc., Tarrytown, NY, USA), FibroTest (BioPredictive, Paris, France), FibroMAX (BioPredictive, Paris, France) and transient elastography (FibroScan(®); produced by EchoSens, Paris, France and distributed in the UK by Artemis Medical Ltd, Kent, UK)] in patients suspected of having ALD. A systematic review was undertaken to identify studies reporting the diagnostic and prognostic accuracy of the ELF test, FibroTest, FibroMAX, and FibroScan for the identification of liver fibrosis and associated conditions in patients with suspected ALD. The following databases were searched in January 2010: MEDLINE (from 1950 to January 2010), MEDLINE In-Process & Other Non-Indexed Citations (from 1950 to January 2010), EMBASE (from 1980 to January 2010), Cochrane Database of Systematic Reviews (from 1996 to January 2010), Cochrane Central Register of Controlled Trials (from 1898 to January 2010), Cochrane Methodology Register (from 1904 to January 2010), Database of Abstracts of Reviews of Effects (from 1995 to January 2010), HTA Database (from 1995 to January 2010), NHS Economic Evaluation Database (from 1995 to January 2010), Cumulative Index to Nursing and Allied Health Literature (from 1982 to January 2010), Web of Knowledge and Science Citation Index (from 1969 to January 2010). Study quality was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) checklist. Owing to the heterogeneity of the studies, no formal meta-analysis was undertaken. A de novo mathematical model was constructed to estimate the incremental costs and incremental quality-adjusted life-years (QALYs) associated with alternative strategies compared with a biopsy-all strategy. The tests are assessed first as a replacement for liver biopsy, and secondly as an additional test prior to liver biopsy. Thirty-six scenarios were assessed for each non-invasive test strategy, which varied the sensitivity of biopsy, the anxiety associated with biopsy, sensitivity and specificity values and whether or not the biopsy was percutaneous or transjugular. For each scenario, threshold levels were reported where biopsying all patients was more cost-effective than the strategy for two parameters (the decreased level of abstinence associated with the strategy compared with biopsying all and the level of incidental QALY gain associated with biopsy). No studies were identified that specifically assessed the ELF test, although a study was identified that evaluated the diagnostic accuracy of the European Liver Fibrosis Test (essentially, the ELF test with the addition of age to the algorithm) compared with biopsy. Three studies of FibroTest, no relevant studies of FibroMax, and six studies of FibroScan assessing accuracy compared with biopsy in patients with known or suspected alcohol-related liver disease were identified. In all studies, the number of patients with suspected ALD was small, meaning that the estimated sensitivities and specificities were not robust. No conclusive estimate of the cost per QALY of each non-invasive test could be provided. Scenarios exist in which each of the strateg

  5. Drug Induced Liver Injury: Can Biomarkers Assist RUCAM in Causality Assessment?

    PubMed Central

    Teschke, Rolf; Schulze, Johannes; Eickhoff, Axel; Danan, Gaby

    2017-01-01

    Drug induced liver injury (DILI) is a potentially serious adverse reaction in a few susceptible individuals under therapy by various drugs. Health care professionals facing DILI are confronted with a wealth of drug-unrelated liver diseases with high incidence and prevalence rates, which can confound the DILI diagnosis. Searching for alternative causes is a key element of RUCAM (Roussel Uclaf Causality Assessment Method) to assess rigorously causality in suspected DILI cases. Diagnostic biomarkers as blood tests would be a great help to clinicians, regulators, and pharmaceutical industry would be more comfortable if, in addition to RUCAM, causality of DILI can be confirmed. High specificity and sensitivity are required for any diagnostic biomarker. Although some risk factors are available to evaluate liver safety of drugs in patients, no valid diagnostic or prognostic biomarker exists currently for idiosyncratic DILI when a liver injury occurred. Identifying a biomarker in idiosyncratic DILI requires detailed knowledge of cellular and biochemical disturbances leading to apoptosis or cell necrosis and causing leakage of specific products in blood. As idiosyncratic DILI is typically a human disease and hardly reproducible in animals, pathogenetic events and resulting possible biomarkers remain largely undisclosed. Potential new diagnostic biomarkers should be evaluated in patients with DILI and RUCAM-based established causality. In conclusion, causality assessment in cases of suspected idiosyncratic DILI is still best achieved using RUCAM since specific biomarkers as diagnostic blood tests that could enhance RUCAM results are not yet available. PMID:28398242

  6. Does clinical pretest probability influence image quality and diagnostic accuracy in dual-source coronary CT angiography?

    PubMed

    Thomas, Christoph; Brodoefel, Harald; Tsiflikas, Ilias; Bruckner, Friederike; Reimann, Anja; Ketelsen, Dominik; Drosch, Tanja; Claussen, Claus D; Kopp, Andreas; Heuschmid, Martin; Burgstahler, Christof

    2010-02-01

    To prospectively evaluate the influence of the clinical pretest probability assessed by the Morise score onto image quality and diagnostic accuracy in coronary dual-source computed tomography angiography (DSCTA). In 61 patients, DSCTA and invasive coronary angiography were performed. Subjective image quality and accuracy for stenosis detection (>50%) of DSCTA with invasive coronary angiography as gold standard were evaluated. The influence of pretest probability onto image quality and accuracy was assessed by logistic regression and chi-square testing. Correlations of image quality and accuracy with the Morise score were determined using linear regression. Thirty-eight patients were categorized into the high, 21 into the intermediate, and 2 into the low probability group. Accuracies for the detection of significant stenoses were 0.94, 0.97, and 1.00, respectively. Logistic regressions and chi-square tests showed statistically significant correlations between Morise score and image quality (P < .0001 and P < .001) and accuracy (P = .0049 and P = .027). Linear regression revealed a cutoff Morise score for a good image quality of 16 and a cutoff for a barely diagnostic image quality beyond the upper Morise scale. Pretest probability is a weak predictor of image quality and diagnostic accuracy in coronary DSCTA. A sufficient image quality for diagnostic images can be reached with all pretest probabilities. Therefore, coronary DSCTA might be suitable also for patients with a high pretest probability. Copyright 2010 AUR. Published by Elsevier Inc. All rights reserved.

  7. Potential Application of Digitally Linked Tuberculosis Diagnostics for Real-Time Surveillance of Drug-Resistant Tuberculosis Transmission: Validation and Analysis of Test Results.

    PubMed

    Ng, Kamela Charmaine; Meehan, Conor Joseph; Torrea, Gabriela; Goeminne, Léonie; Diels, Maren; Rigouts, Leen; de Jong, Bouke Catherine; André, Emmanuel

    2018-02-27

    Tuberculosis (TB) is the highest-mortality infectious disease in the world and the main cause of death related to antimicrobial resistance, yet its surveillance is still paper-based. Rifampicin-resistant TB (RR-TB) is an urgent public health crisis. The World Health Organization has, since 2010, endorsed a series of rapid diagnostic tests (RDTs) that enable rapid detection of drug-resistant strains and produce large volumes of data. In parallel, most high-burden countries have adopted connectivity solutions that allow linking of diagnostics, real-time capture, and shared repository of these test results. However, these connected diagnostics and readily available test results are not used to their full capacity, as we have yet to capitalize on fully understanding the relationship between test results and specific rpoB mutations to elucidate its potential application to real-time surveillance. We aimed to validate and analyze RDT data in detail, and propose the potential use of connected diagnostics and associated test results for real-time evaluation of RR-TB transmission. We selected 107 RR-TB strains harboring 34 unique rpoB mutations, including 30 within the rifampicin resistance-determining region (RRDR), from the Belgian Coordinated Collections of Microorganisms, Antwerp, Belgium. We subjected these strains to Xpert MTB/RIF, GenoType MTBDRplus v2.0, and Genoscholar NTM + MDRTB II, the results of which were validated against the strains' available rpoB gene sequences. We determined the reproducibility of the results, analyzed and visualized the probe reactions, and proposed these for potential use in evaluating transmission. The RDT probe reactions detected most RRDR mutations tested, although we found a few critical discrepancies between observed results and manufacturers' claims. Based on published frequencies of probe reactions and RRDR mutations, we found specific probe reactions with high potential use in transmission studies: Xpert MTB/RIF probes A, Bdelayed, C, and Edelayed; Genotype MTBDRplus v2.0 WT2, WT5, and WT6; and Genoscholar NTM + MDRTB II S1 and S3. Inspection of probe reactions of disputed mutations may potentially resolve discordance between genotypic and phenotypic test results. We propose a novel approach for potential real-time detection of RR-TB transmission through fully using digitally linked TB diagnostics and shared repository of test results. To our knowledge, this is the first pragmatic and scalable work in response to the consensus of world-renowned TB experts in 2016 on the potential of diagnostic connectivity to accelerate efforts to eliminate TB. This is evidenced by the ability of our proposed approach to facilitate comparison of probe reactions between different RDTs used in the same setting. Integrating this proposed approach as a plug-in module to a connectivity platform will increase usefulness of connected TB diagnostics for RR-TB outbreak detection through real-time investigation of suspected RR-TB transmission cases based on epidemiologic linking. ©Kamela Charmaine Ng, Conor Joseph Meehan, Gabriela Torrea, Léonie Goeminne, Maren Diels, Leen Rigouts, Bouke Catherine de Jong, Emmanuel André. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 27.02.2018.

  8. Non-invasive diagnostic platforms in management of non-small cell lung cancer: opportunities and challenges

    PubMed Central

    Pennell, Nathan A.

    2017-01-01

    Several non-invasive diagnostic platforms are already being incorporated in routine clinical practice in the work up and monitoring of patients with lung cancer. These approaches have great potential to improve patient selection and monitor patients while on therapy, however several challenges exist in clinical validation and standardization of such platforms. In this review, we summarize the current technologies available for non-invasive diagnostic evaluation from the blood of patients with non-small cell lung cancer (NSCLC), and discuss the technical and logistical challenges associated incorporating such testing in clinical practice. PMID:29057238

  9. Diagnostic value of two commercial chromatographic "patient-side" tests in the diagnosis of acute canine leptospirosis.

    PubMed

    Gloor, C I; Schweighauser, A; Francey, T; Rodriguez-Campos, S; Vidondo, B; Bigler, B; Schuller, S

    2017-03-01

    To determine the diagnostic performance of two patient-side tests (RDT-1: Test-it™ and RDT-2 Witness®Lepto) in the early diagnosis of canine leptospirosis. Retrospective study of 108 dogs with leptospirosis and 53 controls. Leptospirosis was diagnosed based on compatible clinical and clinicopathologic signs and either a single microscopic agglutination test titre_ >800 (n=49), seroconversion (n=53), positive urine real time PCR (RT-PCR) (n=1), evidence of spirochaetes in silver-stained tissues (n=1) or a combination of these (n=4). Leptospirosis was excluded in dogs with a convincing alternative diagnosis and single microscopic agglutination testing titres _<200 (n=46) or lack of seroconversion (n=7). Indices of diagnostic accuracy of the rapid diagnostic tests were calculated by comparing admission rapid diagnostic test results to the final disease status. Rapid diagnostic test-1 was performed in 118 dogs, rapid diagnostic test-2 in 69 dogs and both tests in 26 dogs. Weak positive results occurred frequently representing 22·6% (rapid diagnostic test-1) and 32·3% (rapid diagnostic test-2) of all positive tests in dogs with leptospirosis. If weak positive rapid diagnostic tests were considered positive, rapid diagnostic test-1 and rapid diagnostic test-2 had sensitivities of 82 and 76%, specificities of 91 and 100%, positive predictive values of 94% and 100% and negative predictive values of 73% and 74%, respectively. There were some technical problems with rapid diagnostic test-1. The diagnostic performance of the rapid diagnostic tests is similar to that reported for the microscopic agglutination test. Both can support a diagnosis of leptospirosis with high specificity but leptospirosis cannot be excluded based on a negative admission test result. Both RDTs are useful in conjunction with other confirmatory tests. © 2017 British Small Animal Veterinary Association.

  10. The development, evaluation and performance of molecular diagnostics for detection of Mycobacterium tuberculosis.

    PubMed

    Bates, Matthew; Zumla, Alimuddin

    2016-01-01

    The unique pathogenesis of tuberculosis (TB) poses several barriers to the development of accurate diagnostics: a) the establishment of life-long latency by Mycobacterium tuberculosis (M.tb) after primary infection confounds the development of classical antibody or antigen based assays; b) our poor understanding of the molecular pathways that influence progression from latent to active disease; c) the intracellular nature of M.tb infection in tissues means that M.tb and/or its components, are not readily detectable in peripheral specimens; and d) the variable presence of M.tb bacilli in specimens from patients with extrapulmonary TB or children. The literature on the current portfolio of molecular diagnostics tests for TB is reviewed here and the developmental pipeline is summarized. Also reviewed are data from recently published operational research on the GeneXpert MTB/RIF assay and discussed are the lessons that can be taken forward for the design of studies to evaluate the impact of TB diagnostics.

  11. Evaluation of four rapid tests for diagnosis and differentiation of HIV-1 and HIV-2 infections in Guinea-Conakry, West Africa.

    PubMed

    Chaillet, Pascale; Tayler-Smith, Katie; Zachariah, Rony; Duclos, Nanfack; Moctar, Diallo; Beelaert, Greet; Fransen, Katrien

    2010-09-01

    With both HIV-1 and HV-2 prevalent in Guinea-Conakry, accurate diagnosis and differentiation is crucial for treatment purposes. Thus, four rapid HIV tests were evaluated for their HIV-1 and HIV-2 diagnostic and discriminative capacity for use in Guinea-Conakry. These included SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), Genie II HIV1/HIV2 (Bio-Rad), First Response HIV Card Test 1-2.0 (PMC Medical) and Immunoflow HIV1-HIV2 (Core Diagnostics). Results were compared with gold standard tests (INNO-LIA HIV-I/II Score) and NEW LAV BLOT II (Bio-Rad). Four hundred and forty three sequential stored HIV-positive serum samples, of known HIV-type, were evaluated. Genie II HIV1/HIV2, Immunoflow HIV1-HIV2 and SD Bioline HIV 1/2 3.0 had 100% sensitivity (95% CI, 98.9-100%) while for First Response HIV Card Test 1-2.0 this was 99.5% (95% CI, 98.2%-99.9%). In terms of discriminatory capacity, Genie II HIV1/HIV2 identified 382/ 384(99.5%) HIV-1 samples, 49/ 52(95%) HIV-2 and 7/7(100%) HIV-positive untypable samples. Immunoflow HIV1-HIV2 identified 99% HIV-1, 67% HIV-2 and all HIV-positive untypable samples. First Response HIV Card Test 1-2.0 identified 94% HIV-1, 64% HIV-2 and 57% HIV-positive untypable samples. SD-Bioline HIV 1/2 3.0 was the worst overall performer identifying 65% HIV-1, 69% HIV-2 and all HIV-positive untypable samples. The use of SD Bioline HIV 1/2 3.0 (the current standard in Guinea-Conakry) as a discriminatory HIV test is poor and may be best replaced by Immunoflow HIV1-HIV2. Copyright 2010 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  12. Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

    PubMed

    Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

    2008-11-01

    Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

  13. What is an ROC curve?

    PubMed

    Hoo, Zhe Hui; Candlish, Jane; Teare, Dawn

    2017-06-01

    The paper by Body et al is concerned with the evaluation of decision aids, which can be used to identify potential acute coronary syndromes (ACS) in the ED. The authors previously developed the Manchester Acute Coronary Syndromes model (MACS) decision aid, which uses several clinical variables and two biomarkers to 'rule in' and 'rule out' ACS. However, one of the two biomarkers (heart-type fatty acid bindingprotein, H-FABP) is not widely used so a revised decision aid has been developed (Troponin-only Manchester Acute Coronary Syndromes, T-MACS), which include a single biomarker hs-cTnT. In this issue, the authors show how they derive a revised decision aid and describe its performance in a number of independent diagnostic cohort studies. Decision aids (as well as other types of 'diagnostic tests') are often evaluated in terms of diagnostic testing parameters such as the area under the receiver operating characteristic (ROC) curve, sensitivity and specificity. In this article, we explain how the ROC analysis is conducted and why it is an essential step towards developing a test with the desirable levels of sensitivity and specificity. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea

    PubMed Central

    Kurosaki, Yohei; Magassouba, N’Faly; Oloniniyi, Olamide K.; Cherif, Mahamoud S.; Sakabe, Saori; Takada, Ayato; Hirayama, Kenji; Yasuda, Jiro

    2016-01-01

    Given the current absence of specific drugs or vaccines for Ebola virus disease (EVD), rapid, sensitive, and reliable diagnostic methods are required to stem the transmission chain of the disease. We have developed a rapid detection assay for Zaire ebolavirus based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and coupled with a novel portable isothermal amplification and detection platform. The RT-LAMP assay is based on primer sets that target the untranscribed trailer region or nucleoprotein coding region of the viral RNA. The test could specifically detect viral RNAs of Central and West African Ebola virus strains within 15 minutes with no cross-reactivity to other hemorrhagic fever viruses and arboviruses, which cause febrile disease. The assay was evaluated using a total of 100 clinical specimens (serum, n = 44; oral swab, n = 56) collected from suspected EVD cases in Guinea. The specificity of this diagnostic test was 100% for both primer sets, while the sensitivity was 100% and 97.9% for the trailer and nucleoprotein primer sets, respectively, compared with a reference standard RT-PCR test. These observations suggest that our diagnostic assay is useful for identifying EVD cases, especially in the field or in settings with insufficient infrastructure. PMID:26900929

  15. Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay Coupled with a Portable Device for Rapid Diagnosis of Ebola Virus Disease in Guinea.

    PubMed

    Kurosaki, Yohei; Magassouba, N'Faly; Oloniniyi, Olamide K; Cherif, Mahamoud S; Sakabe, Saori; Takada, Ayato; Hirayama, Kenji; Yasuda, Jiro

    2016-02-01

    Given the current absence of specific drugs or vaccines for Ebola virus disease (EVD), rapid, sensitive, and reliable diagnostic methods are required to stem the transmission chain of the disease. We have developed a rapid detection assay for Zaire ebolavirus based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and coupled with a novel portable isothermal amplification and detection platform. The RT-LAMP assay is based on primer sets that target the untranscribed trailer region or nucleoprotein coding region of the viral RNA. The test could specifically detect viral RNAs of Central and West African Ebola virus strains within 15 minutes with no cross-reactivity to other hemorrhagic fever viruses and arboviruses, which cause febrile disease. The assay was evaluated using a total of 100 clinical specimens (serum, n = 44; oral swab, n = 56) collected from suspected EVD cases in Guinea. The specificity of this diagnostic test was 100% for both primer sets, while the sensitivity was 100% and 97.9% for the trailer and nucleoprotein primer sets, respectively, compared with a reference standard RT-PCR test. These observations suggest that our diagnostic assay is useful for identifying EVD cases, especially in the field or in settings with insufficient infrastructure.

  16. Assessing stakeholder perceptions of the acceptability and feasibility of national scale-up for a dual HIV/syphilis rapid diagnostic test in Malawi.

    PubMed

    Maddox, Brandy L Peterson; Wright, Shauntā S; Namadingo, Hazel; Bowen, Virginia B; Chipungu, Geoffrey A; Kamb, Mary L

    2017-12-01

    The WHO recommends pregnant women receive both HIV and syphilis testing at their first antenatal care visit, as untreated maternal infections can lead to severe, adverse pregnancy outcomes. One strategy for increasing testing for both HIV and syphilis is the use of point-of-care (rapid) diagnostic tests that are simple, proven effective and inexpensive. In Malawi, pregnant women routinely receive HIV testing, but only 10% are tested for syphilis at their first antenatal care visit. This evaluation explores stakeholder perceptions of a novel, dual HIV/syphilis rapid diagnostic test and potential barriers to national scale-up of the dual test in Malawi. During June and July 2015, we conducted 15 semistructured interviews with 25 healthcare workers, laboratorians, Ministry of Health leaders and partner agency representatives working in prevention of mother-to-child transmission in Malawi. We asked stakeholders about the importance of a dual rapid diagnostic test, concerns using and procuring the dual test and recommendations for national expansion. Stakeholders viewed the test favourably, citing the importance of a dual rapid test in preventing missed opportunities for syphilis diagnosis and treatment, improving infant outcomes and increasing syphilis testing coverage. Primary technical concerns were about the additional procedural steps needed to perform the test, the possibility that testers may not adhere to required waiting times before interpreting results and difficulty reading and interpreting test results. Stakeholders thought national scale-up would require demonstration of cost-savings, uniform coordination, revisions to testing guidelines and algorithms, training of testers and a reliable supply chain. Stakeholders largely support implementation of a dual HIV/syphilis rapid diagnostic test as a feasible alternative to current antenatal testing. Scale-up will require addressing perceived barriers; negotiating changes to existing algorithms and guidelines; and Ministry of Health approval and funding to support training of staff and procurement of supplies. © Article author(s) (or their employer(s) unless otherwise stated in the text of thearticle) 2017. All rights reserved. No commercial use is permitted unless otherwiseexpressly granted.

  17. In Vitro Gluten Challenge Test for Celiac Disease Diagnosis.

    PubMed

    Khalesi, Maryam; Jafari, Seyed Ali; Kiani, Mohammadali; Picarelli, Antonio; Borghini, Raffaele; Sadeghi, Ramin; Eghtedar, Alireza; Ayatollahi, Hosein; Kianifar, Hamid R

    2016-02-01

    The in vitro gluten challenge test is an important diagnostic modality in celiac disease (CD), especially in patients who begin treatment with a gluten-free diet before adequate diagnostic workup or in cases with atypical CD. Available literature was reviewed regarding the accuracy of the in vitro gluten challenge test for CD diagnosis. MEDLINE, Scopus, and Google Scholar were searched, and studies that used serology and bowel biopsy as the criterion standard for diagnosis were included in our study. Data on authors, publication year, characteristics of the patient and control groups, patients' diet, duration of the gluten challenge test, histology findings, endomysial antibody (EMA) and anti-tissue transglutaminase (tTG) levels, CD markers, and intercellular cell adhesion molecule-1, and human leukocyte antigens before and after the gluten challenge test were extracted. Overall, 15 studies were included in this meta-analysis. Pooled sensitivity %/specificity % was 84/99 for EMA after the challenge, 52/96 for EMA without the challenge, 95.5/98.3 for anti-tTG after the challenge, and 95.1/98.3 for anti-tTG without the challenge test. Sensitivity/specificity for immunological markers were 89/97 for the percentage of CD25⁺-lamina propria lymphocytes, 96/91 for the percentage of CD3⁺-lamina propria lymphocytes, and 96.1/85.7 for the percentage of intercellular cell adhesion molecule-1-lamina propria lymphocytes. The factors that increased the sensitivity of EMA were longer test duration, and the evaluation of patients on a gluten-containing diet or short-term gluten-free diet. The in vitro gluten challenge test can be a useful part of the diagnostic workup of CD, rather than only a model to evaluate its mechanisms.

  18. Thiopurine S-methyltransferase testing for averting drug toxicity: a meta-analysis of diagnostic test accuracy

    PubMed Central

    Zur, RM; Roy, LM; Ito, S; Beyene, J; Carew, C; Ungar, WJ

    2016-01-01

    Thiopurine S-methyltransferase (TPMT) deficiency increases the risk of serious adverse events in persons receiving thiopurines. The objective was to synthesize reported sensitivity and specificity of TPMT phenotyping and genotyping using a latent class hierarchical summary receiver operating characteristic meta-analysis. In 27 studies, pooled sensitivity and specificity of phenotyping for deficient individuals was 75.9% (95% credible interval (CrI), 58.3–87.0%) and 98.9% (96.3–100%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 90.4% (79.1–99.4%) and 100.0% (99.9–100%), respectively. For individuals with deficient or intermediate activity, phenotype sensitivity and specificity was 91.3% (86.4–95.5%) and 92.6% (86.5–96.6%), respectively. For genotype tests evaluating TPMT*2 and TPMT*3, sensitivity and specificity was 88.9% (81.6–97.5%) and 99.2% (98.4–99.9%), respectively. Genotyping has higher sensitivity as long as TPMT*2 and TPMT*3 are tested. Both approaches display high specificity. Latent class meta-analysis is a useful method for synthesizing diagnostic test performance data for clinical practice guidelines. PMID:27217052

  19. Our experience with atopy patch tests with aeroallergens.

    PubMed

    Celakovská, Jarmila; Ettlerová, Kvetuse; Ettler, Karel; Vanecková, Jaroslava

    2013-01-01

    Aim of our study was to evaluate the importance of atopy patch testing with aeroallergens as a diagnostic method in patients suffering from atopic dermatitis. The complet dermatological and allergological examinations were performed in 29 patients; 10 men, 19 women with the average age of 27.8 years, min. 17, max. 57 years; with the median SCORAD 24.2 points, s.d. 13.3 points. Wormwood, grass, dog dander, cat dander, dermatophagoides pharinae, dermatophagoides pteronyssinus and birch pollen were examined in diagnostic procedures. Skin prick tests, specific IgE were examined; the atopy patch tests were performed with aeroallergens for skin prick tests in concentration 1 x skin prick tests. Specific IgE and skin prick tests to one or more tested aeroallergens were positive altogether in 27 patients; atopy patch tests were positive only in one of these patients. For atopy patch testing with aeroallergens the concentration of 1 x skin prick tests is low to confirme the eczematic reaction in patients suffering from allergy to inhallant allergens.

  20. Evaluation of patients with methamphetamine- and cocaine-related chest pain in a chest pain observation unit.

    PubMed

    Diercks, Deborah B; Kirk, J Douglas; Turnipseed, Samuel D; Amsterdam, Ezra A

    2007-12-01

    Risk of acute coronary events in patients with methamphetamine and cocaine intoxication has been described. Little is known about the need for additional evaluation in these patients who do not have evidence of myocardial infarction after the initial emergency department evaluation. We herein describe our experience with these patients in a chest pain unit (CPU) and the rate of cardiac-related chest pain in this group. Retrospective analysis of patients evaluated in our CPU from January 1, 2000 to December 16, 2004 with a history of chest pain. Patients who had a positive urine toxicologic screen for methamphetamine or cocaine were included. No patients had ECG or cardiac injury marker evidence of myocardial infarction or ischemia during the initial emergency department evaluation. A diagnosis of cardiac-related chest pain was based upon positive diagnostic testing (exercise stress testing, nuclear perfusion imaging, stress echocardiography, or coronary artery stenosis >70%). During the study period, 4568 patients were evaluated in the CPU. A total of 1690 (37%) of patients admitted to the CPU underwent urine toxicologic testing. The result of urine toxicologic test was positive for cocaine or methamphetamine in 224 (5%). In the 2871 patients who underwent diagnostic testing for coronary artery disease (CAD), 401 (14%) were found to have positive results. There was no difference in the prevalence of CAD between those with positive result for toxicology screens (26/156, 17%) and those without (375/2715, 13%, RR 1.2, 95% CI 0.8-1.7). These findings suggest a relatively high rate of CAD in patients with methamphetamine and cocaine use evaluated in a CPU.

Top