Sample records for diagnostic testing laboratories

  1. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  2. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  3. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...

  4. 42 CFR 414.506 - Procedures for public consultation for payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... a new clinical diagnostic laboratory test. 414.506 Section 414.506 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.506 Procedures for public consultation for payment for a new clinical diagnostic laboratory test...

  5. 76 FR 49491 - Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-10

    ...] Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration... code under the Treatment of Certain Complex Diagnostic Laboratory Tests Demonstration. The deadline for... interested parties of an opportunity to participate in the Treatment of Certain Complex Diagnostic Laboratory...

  6. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  7. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  8. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.509 Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory...

  9. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in the 80000 series of the Current Procedural Terminology published by the American Medical... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  10. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  11. 76 FR 61153 - Robert Raymond Reppy, D.O.; Decision and Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-03

    ... diagnostic and laboratory tests consistent with good medical care,'' ``[f]ormulate[] a therapeutic plan... examination and appropriate diagnostic and laboratory testing.'' Id. In May 2000, the Louisiana State Board of..., examination, physical examination and appropriate diagnostic and laboratory testing; Discussing with the...

  12. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    PubMed

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  13. Development and validation of an immunoperoxidase antigen detection test for improved diagnosis of rabies in Indonesia.

    PubMed

    Rahmadane, Ibnu; Certoma, Andrea F; Peck, Grantley R; Fitria, Yul; Payne, Jean; Colling, Axel; Shiell, Brian J; Beddome, Gary; Wilson, Susanne; Yu, Meng; Morrissy, Chris; Michalski, Wojtek P; Bingham, John; Gardner, Ian A; Allen, John D

    2017-11-01

    Rabies continues to pose a significant threat to human and animal health in regions of Indonesia. Indonesia has an extensive network of veterinary diagnostic laboratories and the 8 National laboratories are equipped to undertake diagnostic testing for rabies using the commercially-procured direct fluorescent antibody test (FAT), which is considered the reference (gold standard) test. However, many of the Indonesian Provincial diagnostic laboratories do not have a fluorescence microscope required to undertake the FAT. Instead, certain Provincial laboratories continue to screen samples using a chemical stain-based test (Seller's stain test, SST). This test has low diagnostic sensitivity, with negative SST-tested samples being forwarded to the nearest National laboratory resulting in significant delays for completion of testing and considerable additional costs. This study sought to develop a cost-effective and diagnostically-accurate immunoperoxidase antigen detection (RIAD) test for rabies that can be readily and quickly performed by the resource-constrained Provincial laboratories. This would reduce the burden on the National laboratories and allow more rapid diagnoses and implementation of post-exposure prophylaxis. The RIAD test was evaluated using brain smears fixed with acetone or formalin and its performance was validated by comparison with established rabies diagnostic tests used in Indonesia, including the SST and FAT. A proficiency testing panel was distributed between Provincial laboratories to assess the reproducibility of the test. The performance of the RIAD test was improved by using acetone fixation of brain smears rather than formalin fixation such that it was of equivalent accuracy to that of the World Organisation for Animal Health (OIE)-recommended FAT, with both tests returning median diagnostic sensitivity and specificity values of 0.989 and 0.993, respectively. The RIAD test and FAT had higher diagnostic sensitivity than the SST (median = 0.562). Proficiency testing using a panel of 6 coded samples distributed to 16 laboratories showed that the RIAD test had good reproducibility with an overall agreement of 97%. This study describes the successful development, characterisation and use of a novel RIAD test and its fitness for purpose as a screening test for use in provincial Indonesian veterinary laboratories.

  14. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... FOR PART B MEDICAL AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests...

  15. 42 CFR 414.509 - Reconsideration of basis for and amount of payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) or § 414.509(a)(3) that the basis for payment for a new test will be gapfilling, CMS posts interim... for a new clinical diagnostic laboratory test. 414.509 Section 414.509 Public Health CENTERS FOR... Laboratory Tests § 414.509 Reconsideration of basis for and amount of payment for a new clinical diagnostic...

  16. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    PubMed

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  17. 76 FR 76736 - Agency Forms Undergoing Paperwork Reduction Act Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-08

    ... Project Survey of Rapid Influenza Diagnostic Test (RIDT) Practices in Laboratories-NEW--the Office of...). Background and Brief Description The Survey of Rapid Influenza Diagnostic Testing Practices in Laboratories is a national systematic study investigating rapid influenza diagnostic testing practices in clinical...

  18. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    PubMed Central

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family physicians. Approaches to ensuring more rational testing are needed. PMID:29146654

  19. Use, location, and timeliness of clinical microbiology testing in Georgia for select infectious diseases.

    PubMed

    Brzozowski, Amanda K; Silk, Benjamin J; Berkelman, Ruth L; Loveys, Deborah A; Caliendo, Angela M

    2012-01-01

    Although clinical microbiology testing facilitates both public health surveillance of infectious diseases and patient care, research on testing patterns is scant. We surveyed hospital laboratories in Georgia to assess their diagnostic testing practices. Using e-mail, all directors of hospital laboratories in Georgia were invited to participate. The survey focused on timing and location of diagnostic testing in 2006 for 6 reportable diseases: giardiasis, legionellosis, meningococcal disease, pertussis, Rocky Mountain spotted fever, and West Nile virus disease. Of 141 laboratories, 62 (44%) responded to the survey. Hospitals varied widely in their use of diagnostic testing in 2006, with 95.1% testing for meningococcal disease, but only 66.1% and 63.3% testing for legionellosis and West Nile virus disease, respectively. Most laboratories (91%) performed gram stain/culture to diagnose meningococcal disease in-house and 23% performed ova and parasite panels for giardiasis were conducted in-house. Fewer than 11% of laboratories performed in-house testing for the remaining diseases. Laboratories affiliated with small hospitals (≤100 beds) were more likely to send specimens for outside testing compared with laboratories associated with large hospitals (>250 beds). Median turnaround time for ova and parasite panel testing for giardiasis was significantly shorter for in-house testing (1.0 days) than within-system (2.25 days) or outside laboratory (3.0 days) testing (P = .0003). No laboratories reported in-house testing for meningococcal disease, pertussis, or Rocky Mountain spotted fever using polymerase chain reaction. Many hospitals did not order diagnostic tests for important infectious diseases during 2006, even for relatively common diseases. In addition, hospital laboratories were unlikely to perform diagnostic testing in-house; sending specimens to an outside laboratory may result in substantial delays in receiving results. These unsettling findings have adverse implications for both patient care and public health surveillance; they indicate an immediate need to study nationally the use and timeliness of clinical microbiologic testing.

  20. Verification of performance specifications of a molecular test: cystic fibrosis carrier testing using the Luminex liquid bead array.

    PubMed

    Lacbawan, Felicitas L; Weck, Karen E; Kant, Jeffrey A; Feldman, Gerald L; Schrijver, Iris

    2012-01-01

    The number of clinical laboratories introducing various molecular tests to their existing test menu is continuously increasing. Prior to offering a US Food and Drug Administration-approved test, it is necessary that performance characteristics of the test, as claimed by the company, are verified before the assay is implemented in a clinical laboratory. To provide an example of the verification of a specific qualitative in vitro diagnostic test: cystic fibrosis carrier testing using the Luminex liquid bead array (Luminex Molecular Diagnostics, Inc, Toronto, Ontario). The approach used by an individual laboratory for verification of a US Food and Drug Administration-approved assay is described. Specific verification data are provided to highlight the stepwise verification approach undertaken by a clinical diagnostic laboratory. Protocols for verification of in vitro diagnostic assays may vary between laboratories. However, all laboratories must verify several specific performance specifications prior to implementation of such assays for clinical use. We provide an example of an approach used for verifying performance of an assay for cystic fibrosis carrier screening.

  1. 78 FR 60245 - Privacy Act Systems of Records; LabWare Laboratory Information Management System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    ... Services Laboratories (NVSL). Diagnostic testing provides official test results for animal imports, exports.... Diagnostic testing is also done in connection with suspected foreign animal disease investigations and... of Records; LabWare Laboratory Information Management System AGENCY: Animal and Plant Health...

  2. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-10-15

    With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.

  3. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    PubMed

    Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K

    2015-01-01

    Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  4. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-01-01

    Introduction With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. Materials and methods In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Results Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Conclusions Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia. PMID:27812306

  5. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...

  6. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...

  7. Pre-examination factors affecting molecular diagnostic test results and interpretation: A case-based approach.

    PubMed

    Payne, Deborah A; Baluchova, Katarina; Peoc'h, Katell H; van Schaik, Ron H N; Chan, K C Allen; Maekawa, Masato; Mamotte, Cyril; Russomando, Graciela; Rousseau, François; Ahmad-Nejad, Parviz

    2017-04-01

    Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. An electronic thesaurus of Evidence Based Laboratory Medicine hematological and biochemical diagnostic tests.

    PubMed

    Dorizzi, R M; Maconi, M; Giavarina, D; Loza, G; Aman, M; Moreira, J; Bisoffi, Z; Gennuso, C

    2009-10-01

    The adoption of Evidence Based Laboratory Medicine (EBLM) has been hampered until today by the lack of effective tools. The SIMeL EBLM e-Thesaurus (on-line Repertoire of the diagnostic effectiveness of the laboratory, radiology and cardiology test) provides a useful support to clinical laboratory professionals and to clinicians for the interpretation of the diagnostic tests. The e-Thesaurus is an application developed using Microsoft Active Server Pages technology and carried out with Web Server Microsoft Internet Information Server and is available at the SIMeL website using a browser running JavaScript scripts (Internet Explorer is recommended). It contains a database (in Italian, English and Spanish) of the sensitivity and specificity (including the 95% confidence interval), the positive and negative likelihood ratios, the Diagnostic Odds Ratio and the Number Needed to Diagnose of more than 2000 diagnostic (most laboratory but also cardiology and radiology) tests. The e-Thesaurus improves the previous SIMeL paper and CD Thesaurus; its main features are a three languages search and a continuous and an easy updating capability.

  9. Integration of next-generation sequencing in clinical diagnostic molecular pathology laboratories for analysis of solid tumours; an expert opinion on behalf of IQN Path ASBL.

    PubMed

    Deans, Zandra C; Costa, Jose Luis; Cree, Ian; Dequeker, Els; Edsjö, Anders; Henderson, Shirley; Hummel, Michael; Ligtenberg, Marjolijn Jl; Loddo, Marco; Machado, Jose Carlos; Marchetti, Antonio; Marquis, Katherine; Mason, Joanne; Normanno, Nicola; Rouleau, Etienne; Schuuring, Ed; Snelson, Keeda-Marie; Thunnissen, Erik; Tops, Bastiaan; Williams, Gareth; van Krieken, Han; Hall, Jacqueline A

    2017-01-01

    The clinical demand for mutation detection within multiple genes from a single tumour sample requires molecular diagnostic laboratories to develop rapid, high-throughput, highly sensitive, accurate and parallel testing within tight budget constraints. To meet this demand, many laboratories employ next-generation sequencing (NGS) based on small amplicons. Building on existing publications and general guidance for the clinical use of NGS and learnings from germline testing, the following guidelines establish consensus standards for somatic diagnostic testing, specifically for identifying and reporting mutations in solid tumours. These guidelines cover the testing strategy, implementation of testing within clinical service, sample requirements, data analysis and reporting of results. In conjunction with appropriate staff training and international standards for laboratory testing, these consensus standards for the use of NGS in molecular pathology of solid tumours will assist laboratories in implementing NGS in clinical services.

  10. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... Nonphysician practitioners (that is, clinical nurse specialists, clinical psychologists, clinical social... that do not involve the use of contrast media; and (iii) Diagnostic mammograms if the approved portable...

  11. Establishing Ebola Virus Disease (EVD) diagnostics using GeneXpert technology at a mobile laboratory in Liberia: Impact on outbreak response, case management and laboratory systems strengthening

    PubMed Central

    Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert

    2018-01-01

    The 2014–16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64–100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can be integrated into other national diagnostic algorithms. The technology has on average a 2-hour sample-to-result time and allows for single specimen testing to overcome potential delays of batching. This model of a mobile laboratory equipped with Xpert Ebola test, staffed by local laboratory technicians, could serve to strengthen outbreak preparedness and response for future outbreaks of EVD in Liberia and the region. PMID:29304039

  12. Establishing Ebola Virus Disease (EVD) diagnostics using GeneXpert technology at a mobile laboratory in Liberia: Impact on outbreak response, case management and laboratory systems strengthening.

    PubMed

    Raftery, Philomena; Condell, Orla; Wasunna, Christine; Kpaka, Jonathan; Zwizwai, Ruth; Nuha, Mahmood; Fallah, Mosoka; Freeman, Maxwell; Harris, Victoria; Miller, Mark; Baller, April; Massaquoi, Moses; Katawera, Victoria; Saindon, John; Bemah, Philip; Hamblion, Esther; Castle, Evelyn; Williams, Desmond; Gasasira, Alex; Nyenswah, Tolbert

    2018-01-01

    The 2014-16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64-100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can be integrated into other national diagnostic algorithms. The technology has on average a 2-hour sample-to-result time and allows for single specimen testing to overcome potential delays of batching. This model of a mobile laboratory equipped with Xpert Ebola test, staffed by local laboratory technicians, could serve to strengthen outbreak preparedness and response for future outbreaks of EVD in Liberia and the region.

  13. An audit of Cryptosporidium and Giardia detection in Scottish National Health Service Diagnostic Microbiology Laboratories.

    PubMed

    Alexander, C L; Currie, S; Pollock, K; Smith-Palmer, A; Jones, B L

    2017-06-01

    Giardia duodenalis and Cryptosporidium species are protozoan parasites capable of causing gastrointestinal disease in humans and animals through the ingestion of infective faeces. Whereas Cryptosporidium species can be acquired locally or through foreign travel, there is the mis-conception that giardiasis is considered to be largely travel-associated, which results in differences in laboratory testing algorithms. In order to determine the level of variation in testing criteria and detection methods between diagnostic laboratories for both pathogens across Scotland, an audit was performed. Twenty Scottish diagnostic microbiology laboratories were invited to participate with questions on sample acceptance criteria, testing methods, testing rates and future plans for pathogen detection. Reponses were received from 19 of the 20 laboratories representing each of the 14 territorial Health Boards. Detection methods varied between laboratories with the majority performing microscopy, one using a lateral flow immunochromatographic antigen assay, another using a manually washed plate-based enzyme immunoassay (EIA) and one laboratory trialling a plate-based EIA automated with an EIA plate washer. Whereas all laboratories except one screened every stool for Cryptosporidium species, an important finding was that significant variation in the testing algorithm for detecting Giardia was noted with only four laboratories testing all diagnostic stools. The most common criteria were 'travel history' (11 laboratories) and/or 'when requested' (14 laboratories). Despite only a small proportion of stools being examined in 15 laboratories for Giardia (2%-18% of the total number of stools submitted), of interest is the finding that a higher positivity rate was observed for Giardia than Cryptosporidium in 10 of these 15 laboratories. These findings highlight that the underreporting of Giardia in Scotland is likely based on current selection and testing algorithms.

  14. External quality assessment of dengue and chikungunya diagnostics in the Asia Pacific region, 2015

    PubMed Central

    Soh, Li Ting; Squires, Raynal C; Tan, Li Kiang; Pok, Kwoon Yong; Yang, HuiTing; Liew, Christina; Shah, Aparna Singh; Aaskov, John; Abubakar, Sazaly; Hasabe, Futoshi; Ng, Lee Ching

    2016-01-01

    Objective To conduct an external quality assessment (EQA) of dengue and chikungunya diagnostics among national-level public health laboratories in the Asia Pacific region following the first round of EQA for dengue diagnostics in 2013. Methods Twenty-four national-level public health laboratories performed routine diagnostic assays on a proficiency testing panel consisting of two modules. Module A contained serum samples spiked with cultured dengue virus (DENV) or chikungunya virus (CHIKV) for the detection of nucleic acid and DENV non-structural protein 1 (NS1) antigen. Module B contained human serum samples for the detection of anti-DENV antibodies. Results Among 20 laboratories testing Module A, 17 (85%) correctly detected DENV RNA by reverse transcription polymerase chain reaction (RT–PCR), 18 (90%) correctly determined serotype and 19 (95%) correctly identified CHIKV by RT–PCR. Ten of 15 (66.7%) laboratories performing NS1 antigen assays obtained the correct results. In Module B, 18/23 (78.3%) and 20/20 (100%) of laboratories correctly detected anti-DENV IgM and IgG, respectively. Detection of acute/recent DENV infection by both molecular (RT–PCR) and serological methods (IgM) was available in 19/24 (79.2%) participating laboratories. Discussion Accurate laboratory testing is a critical component of dengue and chikungunya surveillance and control. This second round of EQA reveals good proficiency in molecular and serological diagnostics of these diseases in the Asia Pacific region. Further comprehensive diagnostic testing, including testing for Zika virus, should comprise future iterations of the EQA. PMID:27508088

  15. First round of external quality assessment of dengue diagnostics in the WHO Western Pacific Region, 2013.

    PubMed

    Pok, Kwoon Yong; Squires, Raynal C; Tan, Li Kiang; Takasaki, Tomohiko; Abubakar, Sazaly; Hasebe, Futoshi; Partridge, Jeffrey; Lee, Chin Kei; Lo, Janice; Aaskov, John; Ng, Lee Ching; Konings, Frank

    2015-01-01

    Accurate laboratory testing is a critical component of dengue surveillance and control. The objective of this programme was to assess dengue diagnostic proficiency among national-level public health laboratories in the World Health Organization (WHO) Western Pacific Region. Nineteen national-level public health laboratories performed routine dengue diagnostic assays on a proficiency testing panel consisting of two modules: one containing commercial serum samples spiked with cultured dengue viruses for the detection of nucleic acid and non-structural protein 1 (NS1) (Module A) and one containing human serum samples for the detection of anti-dengue virus antibodies (Module B). A review of logistics arrangements was also conducted. All 16 laboratories testing Module A performed reverse transcriptase polymerase chain reaction (RT-PCR) for both RNA and serotype detection. Of these, 15 had correct results for RNA detection and all 16 correctly serotyped the viruses. All nine laboratories performing NS1 antigen detection obtained the correct results. Sixteen of the 18 laboratories using IgM assays in Module B obtained the correct results as did the 13 laboratories that performed IgG assays. Detection of ongoing/recent dengue virus infection by both molecular (RT-PCR) and serological methods (IgM) was available in 15/19 participating laboratories. This first round of external quality assessment of dengue diagnostics was successfully conducted in national-level public health laboratories in the WHO Western Pacific Region, revealing good proficiency in both molecular and serological testing. Further comprehensive diagnostic testing for dengue virus and other priority pathogens in the Region will be assessed during future rounds.

  16. The changing face of hemostasis testing in modern laboratories: consolidation, automation, and beyond.

    PubMed

    Lippi, Giuseppe; Plebani, Mario; Favaloro, Emmanuel J

    2015-04-01

    The reality of laboratory diagnostics as a whole, and hemostasis testing in particular, is evolving under new paradigms of efficiency. The driving forces of health care and laboratory diagnostics in the third millennium are mainly represented by macro- and microeconomics. In a world with limited resources, shattered by an unprecedented economic crisis, laboratory diagnostics is undergoing a substantial reorganization, with emergence of new models under the imperative of terms, such as bedside testing, consolidation, and networking. The paradigms under which these changes are being developed include a variety of environment, preanalytical, technological, professional, and health-care aspects. The maintenance of continued quality is indeed the major challenge to be faced in the foreseeable future. In fact, some challenges prepotently emerge during a consolidation process, which basically involve delayed testing, centrifugation, transportation, and stability of the specimens, as well as the potential mismatch of sample matrix. This article is aimed to provide an overview of the current economic scenario of laboratory diagnostics and discuss the changing face of hemostasis testing in modern laboratories, providing a synthetic overview about potential drawbacks of actualized solutions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. The role of diagnostic laboratories in support of animal disease surveillance systems.

    PubMed

    Zepeda, C

    2007-01-01

    Diagnostic laboratories are an essential component of animal disease surveillance systems. To understand the occurrence of disease in populations, surveillance systems rely on random or targeted surveys using three approaches: clinical, serological and virological surveillance. Clinical surveillance is the basis for early detection of disease and is usually centered on the detection of syndromes and clinical findings requiring confirmation by diagnostic laboratories. Although most of the tests applied usually perform to an acceptable standard, several have not been properly validated in terms of their diagnostic sensitivity and specificity. Sensitivity and specificity estimates can vary according to local conditions and, ideally, should be determined by national laboratories where the tests are to be applied. The importance of sensitivity and specificity estimates in the design and interpretation of statistically based surveys and risk analysis is fundamental to establish appropriate disease control and prevention strategies. The World Organisation for Animal Health's (OIE) network of reference laboratories acts as centers of expertise for the diagnosis of OIE listed diseases and have a role in promoting the validation of OIE prescribed tests for international trade. This paper discusses the importance of the epidemiological evaluation of diagnostic tests and the role of the OIE Reference Laboratories and Collaborating Centres in this process.

  18. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    PubMed Central

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  19. Clinical Laboratories – Production Factories or Specialized Diagnostic Centers

    PubMed Central

    Tóth, Judit

    2016-01-01

    Since a large proportion of medical decisions are based on laboratory results, clinical laboratories should meet the increasing demand of clinicians and their patients. Huge central laboratories may process over 10 million tests annually; they act as production factories, measuring emergency and routine tests with sufficient speed and accuracy. At the same time, they also serve as specialized diagnostic centers where well-trained experts analyze and interpret special test results. It is essential to improve and constantly monitor this complex laboratory service, by several methods. Sample transport by pneumatic tube system, use of an advanced laboratory information system and point-of-care testing may result in decreased total turnaround time. The optimization of test ordering may result in a faster and more cost-effective laboratory service. Autovalidation can save time for laboratory specialists, when the analysis of more complex results requires their attention. Small teams of experts responsible for special diagnostic work, and their interpretative reporting according to predetermined principles, may help to minimize subjectivity of these special reports. Although laboratory investigations have become so diversely developed in the past decades, it is essential that the laboratory can provide accurate results relatively quickly, and that laboratory specialists can support the diagnosis and monitoring of patients by adequate interpretation of esoteric laboratory methods. PMID:27683528

  20. Clinical pathologist in Korea--training program and its roles in laboratories.

    PubMed

    Cho, Han-Ik; Lee, Kap No; Park, Jong-Woo; Park, Hyosoon; Kwak, Yun Sik

    2002-01-01

    A rapid development of practice of laboratory medicine in Korea owes its success to the clinical pathologists (CP), who have played a role of a pathfinder for laboratories. The Korean CP postgraduate education (residency) program is unique in that it is exclusively for laboratory medicine. The training program for clinical pathologists includes diagnostic hematology, diagnostic immunology, clinical microbiology, clinical chemistry, blood bank, diagnostic genetics, informatics and laboratory management. The program has produced a strong group of about 600 laboratory physicians, officially clinical pathologists since 1963. Most of Korean clinical pathologists work as laboratory directors, directors of university hospital laboratories or teaching faculty members in medical schools. The roles of clinical pathologists are laboratory management, interpretation of laboratory test results, clinical consulting services to clinicians and patients, ordering secondary tests after reviews of requested test results and utilization management. The clinical pathologists have developed clinical laboratories to be a main contributor for improved medical practice. During the last 40 years under the turbulent healthcare system, clinical pathologists have significantly contributed to safeguard the laboratory interests. The education program and the role of clinical pathologists are described.

  1. 78 FR 20112 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ...-related information. The respondents would be clinical laboratory supervisors, nurses, and other.../60 300 Supervisors. Influenza Diagnostic Test Practices in Clinical Laboratories. Nurses Survey of... this notice. Proposed Project Survey of Rapid Influenza Diagnostic Test (RIDT) Practices in Clinical...

  2. Clinically expedient reporting of rapid diagnostic test information.

    PubMed

    Doern, G V

    1986-03-01

    With the development of rapid diagnostic tests in the clinical microbiology laboratory has come an awareness of the importance of rapid results reporting. Clearly, the potential clinical impact of rapid diagnostic tests is dependent on expeditious reporting. Traditional manual reporting systems are encumbered by the necessity of transcription of test information onto hard copy reports and then the subsequent distribution of such reports into the hands of the user. Laboratory computers when linked directly to CRTs located in nursing stations, ambulatory clinics, or physician's offices, both inside and outside of the hospital, permit essentially instantaneous transfer of test results from the laboratory to the clinician. Computer-assisted results reporting, while representing a significant advance over manual reporting systems is not, however, without problems. Concerns include validation of test information, authorization of users with access to test information, mechanical integrity, and cost. These issues notwithstanding, computerized results reporting will undoubtedly play a central role in optimizing the clinical impact of rapid diagnostic tests.

  3. Argonne Collaborative Center for Energy Storage Science (ACCESS)

    Science.gov Websites

    Analysis and Diagnostics Laboratory (EADL) Post- Test Facility Access Proven Capabilities Argonne has Analysis, Modeling and Prototyping (CAMP) Electrochemical Analysis and Diagnostics Laboratory (EADL) Post -Test Facility Argonne User Facilities Industries Transportation Consumer Electronics Defense Electric

  4. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories.

    PubMed

    Jang, Mi Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong Ho; Min, Won Ki; Lee, Ji Sung; Lee, Yong Wha; Lee, You Kyoung

    2017-05-01

    Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. © The Korean Society for Laboratory Medicine

  5. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories

    PubMed Central

    Jang, Mi-Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong-Ho; Min, Won-Ki; Lee, Ji Sung

    2017-01-01

    Background Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. Methods We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Results Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. Conclusions These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. PMID:28224767

  6. Concordance in diagnostic testing for respiratory pathogens of bighorn sheep

    USGS Publications Warehouse

    Walsh, Daniel P.; Cassirer, E. Frances; Bonds, Michael D.; Brown, Daniel R.; Edwards, William H.; Weiser, Glen C.; Drew, Mark L.; Briggs, Robert E.; Fox, Karen A.; Miller, Michael W.; Shanthalingam, Sudarvili; Srikumaran, Subramaniam; Besser, Thomas E.

    2016-01-01

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack of appropriate standardized commercial kits. Results of diagnostic testing may also be called into question when investigators report different etiologies for disease outbreaks, despite similar clinical and pathologic findings. To evaluate reliability of diagnostic testing for respiratory pathogens of bighorn sheep (Ovis canadensis), we conducted a series of ring tests across 6 laboratories routinely involved in detection of Mycoplasma ovipneumoniae, Pasteurellaceae, lktA (the Pasteurellaceae gene encoding leukotoxin), and 3 reference laboratories. Consistency of results for replicate samples within laboratories was high (median agreement = 1.0). Agreement between laboratories was high for polymerase chain reaction (PCR) detection of M. ovipneumoniae and culture isolation of Mannheimia spp. and Bibersteinia trehalosi(median agreement = 0.89–0.95, Kappa = 0.65–0.74), and lower for PCR detection of Mannheimiaspp. lktA (median agreement = 0.58, Kappa = 0.12). Most errors on defined status samples were false negatives, suggesting test sensitivity was a greater problem than specificity. However, tests for M. haemolytica and lktA yielded some false positive results. Despite differences in testing protocols, median agreement among laboratories and correct classification of controls for most agents was ≥0.80, meeting or exceeding the standard required by federal proficiency testing programs. This information is valuable for interpreting test results, laboratory quality assessments, and advancing diagnosis of respiratory disease in wild sheep. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  7. The cobas® 6800/8800 System: a new era of automation in molecular diagnostics.

    PubMed

    Cobb, Bryan; Simon, Christian O; Stramer, Susan L; Body, Barbara; Mitchell, P Shawn; Reisch, Natasa; Stevens, Wendy; Carmona, Sergio; Katz, Louis; Will, Stephen; Liesenfeld, Oliver

    2017-02-01

    Molecular diagnostics is a key component of laboratory medicine. Here, the authors review key triggers of ever-increasing automation in nucleic acid amplification testing (NAAT) with a focus on specific automated Polymerase Chain Reaction (PCR) testing and platforms such as the recently launched cobas® 6800 and cobas® 8800 Systems. The benefits of such automation for different stakeholders including patients, clinicians, laboratory personnel, hospital administrators, payers, and manufacturers are described. Areas Covered: The authors describe how molecular diagnostics has achieved total laboratory automation over time, rivaling clinical chemistry to significantly improve testing efficiency. Finally, the authors discuss how advances in automation decrease the development time for new tests enabling clinicians to more readily provide test results. Expert Commentary: The advancements described enable complete diagnostic solutions whereby specific test results can be combined with relevant patient data sets to allow healthcare providers to deliver comprehensive clinical recommendations in multiple fields ranging from infectious disease to outbreak management and blood safety solutions.

  8. 42 CFR 419.2 - Basis of payment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... prospective payment system establishes a national payment rate, standardized for geographic wage differences...) Capital-related costs; (9) Implantable items used in connection with diagnostic X-ray tests, diagnostic laboratory tests, and other diagnostic tests; (10) Durable medical equipment that is implantable; (11...

  9. Medical microbiology: laboratory diagnosis of invasive pneumococcal disease.

    PubMed

    Werno, Anja M; Murdoch, David R

    2008-03-15

    The laboratory diagnosis of invasive pneumococcal disease (IPD) continues to rely on culture-based methods that have been used for many decades. The most significant recent developments have occurred with antigen detection assays, whereas the role of nucleic acid amplification tests has yet to be fully clarified. Despite developments in laboratory diagnostics, a microbiological diagnosis is still not made in most cases of IPD, particularly for pneumococcal pneumonia. The limitations of existing diagnostic tests impact the ability to obtain accurate IPD burden data and to assess the effectiveness of control measures, such as vaccination, in addition to the ability to diagnose IPD in individual patients. There is an urgent need for improved diagnostic tests for pneumococcal disease--especially tests that are suitable for use in underresourced countries.

  10. 42 CFR 419.2 - Basis of payment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... prospective payment system establishes a national payment rate, standardized for geographic wage differences... X-ray tests, diagnostic laboratory tests, and other diagnostic tests; (10) Durable medical equipment...

  11. Preliminary assessment of the diagnostic performances of a new rapid diagnostic test for the serodiagnosis of human cystic echinococcosis.

    PubMed

    Vola, Ambra; Tamarozzi, Francesca; Noordin, Rahmah; Yunus, Muhammad Hafiznur; Khanbabaie, Sam; De Silvestri, Annalisa; Brunetti, Enrico; Mariconti, Mara

    2018-04-14

    Rapid diagnostic tests for cystic echinococcosis (CE) are convenient to support ultrasound diagnosis in uncertain cases, especially in resource-limited settings. We found comparable diagnostic performances of the experimental Hyd Rapid Test and the commercial VIRapid HYDATIDOSIS Test, used in our diagnostic laboratory, using samples from well-characterized hepatic CE cases. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Autoimmune diagnostics: the technology, the strategy and the clinical governance.

    PubMed

    Bizzaro, Nicola; Tozzoli, Renato; Villalta, Danilo

    2015-02-01

    In recent years, there has been a profound change in autoimmune diagnostics. From long, tiring and inaccurate manual methods, the art of diagnostics has turned to modern, rapid and automated technology. New antibody tests have been developed, and almost all autoimmune diseases now have some specific diagnostic markers. The current need to make the most of available economic and human resources has led to the production of diagnostic algorithms and guidelines designated for optimal strategic use of the tests and to increase the diagnostic appropriateness. An important role in this scenario was assumed by the laboratory autoimmunologist, whose task is not only to govern the analytical phase, but also to help clinicians in correctly choosing the most suitable test for each clinical situation and provide consultancy support. In this review, we summarize recent advances in technology, describe the diagnostic strategies and highlight the current role of the laboratory autoimmunologist in the clinical governance of autoimmune diagnostics.

  13. Advancing the education in molecular diagnostics: the IFCC-Initiative "Clinical Molecular Biology Curriculum" (C-CMBC); a ten-year experience.

    PubMed

    Lianidou, Evi; Ahmad-Nejad, Parviz; Ferreira-Gonzalez, Andrea; Izuhara, Kenji; Cremonesi, Laura; Schroeder, Maria-Eugenia; Richter, Karin; Ferrari, Maurizio; Neumaier, Michael

    2014-09-25

    Molecular techniques are becoming commonplace in the diagnostic laboratory. Their applications influence all major phases of laboratory medicine including predisposition/genetic risk, primary diagnosis, therapy stratification and prognosis. Readily available laboratory hardware and wetware (i.e. consumables and reagents) foster rapid dissemination to countries that are just establishing molecular testing programs. Appropriate skill levels extending beyond the technical procedure are required for analytical and diagnostic proficiency that is mandatory in molecular genetic testing. An international committee (C-CMBC) of the International Federation for Clinical Chemistry (IFCC) was established to disseminate skills in molecular genetic testing in member countries embarking on the respective techniques. We report the ten-year experience with different teaching and workshop formats for beginners in molecular diagnostics. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Laboratory development and testing of spacecraft diagnostics

    NASA Astrophysics Data System (ADS)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  15. Point of care investigations in pediatric care to improve health care in rural areas.

    PubMed

    Walia, Kamini

    2013-07-01

    The good quality laboratory services in developing countries are often limited to major urban centers. As a result, many commercially available high-quality diagnostic tests for infectious diseases are neither accessible nor affordable to patients in the rural areas. Health facilities in rural areas are compromised and this limits the usability and performance of the best medical diagnostic technologies in rural areas as they are designed for air-conditioned laboratories, refrigerated storage of chemicals, a constant supply of calibrators and reagents, stable electrical power, highly trained personnel and rapid transportation of samples. The advent of new technologies have allowed miniaturization and integration of complex functions, which has made it possible for sophisticated diagnostic tools to move out of the developed-world laboratory in the form of a "point of care"(POC) tests. Many diagnostic tests are being developed using these platforms. However, the challenge is to develop diagnostics which are inexpensive, rugged and well suited to the medical and social contexts of the developing world and do not compromise on accuracy and reliability. The already available POC tests which are reliable and affordable, like for HIV infection, malaria, syphilis, and some neglected tropical diseases, and POC tests being developed for other diseases if correctly used and effectively regulated after rigorous evaluation, have the potential to make a difference in clinical management and improve surveillance. In order to use these tests effectively they would need to be supported by technically competent manpower, availability of good-quality reagents, and healthcare providers who value and are able to interpret laboratory results to guide treatment; and a system for timely communication between the laboratory and the healthcare provider. Strengthening the laboratories at the rural level can enable utilization of these diagnostics for improving the diagnosis and management of infectious diseases among children which require prompt treatment and thus, considerably reduce morbidity and mortality among the pediatric age group.

  16. District, state or regional veterinary diagnostic laboratories.

    PubMed

    Gosser, H S; Morehouse, L G

    1998-08-01

    The district, regional or state laboratory is the local laboratory to which veterinarian practitioners usually submit samples, and consequently these laboratories are usually the first to observe a suspected disease problem. In most countries, these laboratories are under the jurisdiction of the State or region in which they are located. In the United States of America (USA), most veterinary diagnostic laboratories are State-associated and operate under the aegis of either the State Department of Agriculture or a university. The national laboratory provides reference assistance to the State laboratories. In the USA, the national Laboratory (the National Veterinary Services Laboratories) acts as a consultant to confirm difficult diagnoses and administer performance tests for State-associated laboratories. District, state or regional laboratories need to share information regarding technological advances in diagnostic procedures. This need was met in the USA by the formation of the American Association of Veterinary Laboratory Diagnosticians (AAVLD) in the late 1950s. Another requirement of district, state or regional diagnostic laboratories is a method to confirm quality assurance, which was fulfilled in the USA by an accreditation programme established through the AAVLD. The Accreditation Committee evaluates laboratories (on request) in terms of organisation, personnel, physical facilities and equipment, records, finance and budget. Those laboratories which meet the standards as established in the 'Essential Requirements for Accreditation' are given accreditation status, which indicates that they have the expertise and facilities to perform tests on food-producing animals for shipment in national or international commerce and on companion, laboratory or zoo animals. While confidentiality of test records is most important, it is becoming necessary to release certain types of animal disease test information if a country is to participate in the exportation of animals and animal products. As district, state and regional laboratories operate under many different administrative entities (i.e., universities, State governments and the Federal government), various checks at different administrative levels provide safeguards and reduce the possibility of faulty disease reporting.

  17. External quality assessment studies for laboratory performance of molecular and serological diagnosis of Chikungunya virus infection.

    PubMed

    Jacobsen, Sonja; Patel, Pranav; Schmidt-Chanasit, Jonas; Leparc-Goffart, Isabelle; Teichmann, Anette; Zeller, Herve; Niedrig, Matthias

    2016-03-01

    Since the re-emergence of Chikungunya virus (CHIKV) in Reunion in 2005 and the recent outbreak in the Caribbean islands with an expansion to the Americas the CHIK diagnostic became very important. We evaluate the performance of laboratories regarding molecular and serological diagnostic of CHIK worldwide. A panel of 12 samples for molecular and 13 samples for serology were provided to 60 laboratories in 40 countries for evaluating the sensitivity and specificity of molecular and serology testing. The panel for molecular diagnostic testing was analysed by 56 laboratories returning 60 data sets of results whereas the 56 and 60 data sets were returned for IgG and IgM diagnostic from the participating laboratories. Twenty-three from 60 data sets performed optimal, 7 acceptable and 30 sets of results require improvement. From 50 data sets only one laboratory shows an optimal performance for IgM detection, followed by 9 data sets with acceptable and the rest need for improvement. From 46 IgG serology data sets 20 provide an optimal, 2 an acceptable and 24 require improvement performance. The evaluation of some of the diagnostic performances allows linking the quality of results to the in-house methods or commercial assays used. The external quality assurance for CHIK diagnostics provides a good overview on the laboratory performance regarding sensitivity and specificity for the molecular and serology diagnostic required for the quick and reliable analysis of suspected CHIK patients. Nearly half of the laboratories have to improve their diagnostic profile to achieve a better performance. Copyright © 2016 Z. Published by Elsevier B.V. All rights reserved.

  18. Basic haemoglobinopathy diagnostics in Dutch laboratories; providing an informative test result.

    PubMed

    Kaufmann, J O; Smit, J W; Huisman, W; Idema, R N; Bakker, E; Giordano, P C

    2013-08-01

    After a first survey in 2001, the Dutch Association of Hematological Laboratory Research (VHL) advised its members to adopt a basic protocol for haemoglobinopathy carrier detection and to provide genetic information with all positive results to allow health-care professionals to inform carriers about potential genetic risks. This article reports on the compliance with these recommendations and their consequences. Clinical chemists of all 106 Dutch laboratories were invited to answer a survey on patient population, diagnostic techniques used, (self-reported) knowledge, use and effect of the additional information. The average increase in diagnostic output was over 60% and the recommended basic protocol was applied by 65% of the laboratories. Over 84% of the laboratories reported to be aware of the additional recommendations and 77% to be using them. Most laboratories with limited diagnostic requests were still sending their cases to other laboratories and included the genetic information received from these laboratories in their diagnostic reports. The effect of information on subsequent 'family analysis' was estimated to be between 26 and 50%. The present study shows an increase in diagnostic potential for haemoglobinopathy over the last decade, especially in the larger cities. Low 'family testing' rates were mostly found in areas with lower carrier prevalence or associated with local reluctance to pass the information to carriers. In spite of a dramatic improvement, too many carriers are still not informed because of lack of awareness among health-care providers and more education is needed. © 2012 John Wiley & Sons Ltd.

  19. Survey of laboratory practices for diagnosis of fungal infection in seven Asian countries: An Asia Fungal Working Group (AFWG) initiative.

    PubMed

    Chindamporn, Ariya; Chakrabarti, Arunaloke; Li, Ruoyu; Sun, Pei-Lun; Tan, Ban-Hock; Chua, Mitzi; Wahyuningsih, Retno; Patel, Atul; Liu, Zhengyin; Chen, Yee-Chun; Chayakulkeeree, Methee

    2018-06-01

    An online survey of mycology laboratories in seven Asian countries was conducted to assess the status, competence, and services available. Country representatives from the Asia Fungal Working Group (AFWG) contacted as many laboratories performing mycology diagnosis as possible in their respective countries, requesting that the laboratory heads complete the online survey. In total, 241 laboratories responded, including 71 in China, 104 in India, 11 in Indonesia, 26 in the Philippines, four in Singapore, 18 in Taiwan, and seven in Thailand. Overall, 129/241 (53.5%) surveyed mycology laboratories operate as separate designated mycology laboratories, 75/241 (31.1%) conduct regular formal staff training, 103/241 (42.7%) are accredited, and 88/157 (56.1%) participate in external quality assurance scheme (EQAS) programs. Microscopy and culture methods are available in nearly all laboratories, although few perform DNA sequencing (37/219; 16.9%) or use matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy (MALDI-TOF MS) (27/219; 12.3%) for isolate identification. Antifungal susceptibility testing is performed in 142/241 (58.9%) laboratories, mainly for yeasts. The most commonly performed nonculture diagnostic is cryptococcal antigen testing (66 laboratories), followed by galactomannan testing (55), polymerase chain reaction (PCR) diagnosis (37), and beta-D-glucan testing (24). Therapeutic drug monitoring is conducted in 21 laboratories. There is almost no access to advanced diagnostic tests, like galactomannan, β-D-glucan, and PCR, in the surveyed laboratories in Indonesia, the Philippines, and Thailand. These results highlight the need for development of quality laboratories, accreditation and training of manpower in existing laboratories, and access to advanced non-culture-based diagnostic tests to facilitate the diagnosis of fungal infections in Asia.

  20. How clinicians should use the diagnostic laboratory in a changing medical world.

    PubMed

    Lundberg, G D

    1999-02-01

    In developed countries, clinicians are faced with a plethora of diagnostic tests to apply to patients to guide their clinical management. The quality, effectiveness, and efficiency of patient care should be foremost in the clinician's mind. Laboratory directors should make every effort to guide clinicians in appropriate laboratory test ordering, interpretation, and resulting actions. Medicine, being at its center a moral enterprise grounded in a covenant of trust, and laboratory medicine being a subset of medicine, must first care and advocate for the patient, and consider clinical outcomes as most important.

  1. Roles of laboratories and laboratory systems in effective tuberculosis programmes.

    PubMed

    Ridderhof, John C; van Deun, Armand; Kam, Kai Man; Narayanan, P R; Aziz, Mohamed Abdul

    2007-05-01

    Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB.

  2. Methodology in diagnostic laboratory test research in clinical chemistry and clinical chemistry and laboratory medicine.

    PubMed

    Lumbreras-Lacarra, Blanca; Ramos-Rincón, José Manuel; Hernández-Aguado, Ildefonso

    2004-03-01

    The application of epidemiologic principles to clinical diagnosis has been less developed than in other clinical areas. Knowledge of the main flaws affecting diagnostic laboratory test research is the first step for improving its quality. We assessed the methodologic aspects of articles on laboratory tests. We included articles that estimated indexes of diagnostic accuracy (sensitivity and specificity) and were published in Clinical Chemistry or Clinical Chemistry and Laboratory Medicine in 1996, 2001, and 2002. Clinical Chemistry has paid special attention to this field of research since 1996 by publishing recommendations, checklists, and reviews. Articles were identified through electronic searches in Medline. The strategy combined the Mesh term "sensitivity and specificity" (exploded) with the text words "specificity", "false negative", and "accuracy". We examined adherence to seven methodologic criteria used in the study by Reid et al. (JAMA1995;274:645-51) of papers published in general medical journals. Three observers evaluated each article independently. Seventy-nine articles fulfilled the inclusion criteria. The percentage of studies that satisfied each criterion improved from 1996 to 2002. Substantial improvement was observed in reporting of the statistical uncertainty of indices of diagnostic accuracy, in criteria based on clinical information from the study population (spectrum composition), and in avoidance of workup bias. Analytical reproducibility was reported frequently (68%), whereas information about indeterminate results was rarely provided. The mean number of methodologic criteria satisfied showed a statistically significant increase over the 3 years in Clinical Chemistry but not in Clinical Chemistry and Laboratory Medicine. The methodologic quality of the articles on diagnostic test research published in Clinical Chemistry and Clinical Chemistry and Laboratory Medicine is comparable to the quality observed in the best general medical journals. The methodologic aspects that most need improvement are those linked to the clinical information of the populations studied. Editorial actions aimed to increase the quality of reporting of diagnostic studies could have a relevant positive effect, as shown by the improvement observed in Clinical Chemistry.

  3. Changes in laboratory test results and diagnostic imaging presentation before the detection of occupational cholangiocarcinoma.

    PubMed

    Kubo, Shoji; Takemura, Shigekazu; Sakata, Chikaharu; Urata, Yorihisa; Nishioka, Takayoshi; Nozawa, Akinori; Kinoshita, Masahiko; Hamano, Genya; Nakanuma, Yasuni; Endo, Ginji

    2014-01-01

    A cholangiocarcinoma outbreak among workers of an offset color proof-printing department in a printing company was recently reported. It is important to understand the clinical course leading to occupational cholangiocarcinoma development for investigation of the carcinogenesis process and for surveillance and early detection. We evaluated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma. We investigated the changes in laboratory test results and diagnostic imaging presentation before the detection of cholangiocarcinoma in 2 patients because the data were available. Results The clinical courses observed in the 2 participating patients showed persistent elevation of serum γ-glutamyl transpeptidase levels with or without elevated serum levels of alanine aminotransferase and/or aspartate aminotransferase before cholangiocarcinoma detection. Dilatation of the bile ducts without tumor-induced stenosis was observed several years before cholangiocarcinoma detection and progressed gradually in both patients. The serum concentration of carbohydrate 19-9 also increased prior to cholangiocarcinoma detection in both patients. Eventually, observation of stenosis of the bile duct and a space-occupying lesion strongly suggested cholangiocarcinoma. Pathological examination of the resected specimens showed chronic bile duct injury and neoplastic lesions, such as "biliary intraepithelial neoplasia" and "intraductal papillary neoplasm of the bile duct" in various sites of the bile ducts, particularly in the dilated bile ducts. The changes in laboratory test results and diagnostic imaging might be related to the development of cholangiocarcinoma. It is important to monitor diagnostic imaging presentation and laboratory test results in workers with extended exposure to organic solvents.

  4. Impact of clinical awareness and diagnostic tests on the underdiagnosis of Clostridium difficile infection.

    PubMed

    Alcalá, L; Reigadas, E; Marín, M; Martín, A; Catalán, P; Bouza, E

    2015-08-01

    A multicenter study of Clostridium difficile infection (CDI) performed during 2008 in Spain revealed that two of every three episodes went undiagnosed or were misdiagnosed owing to nonsensitive diagnostic tests or lack of clinical suspicion and request. Since then, efforts have been made to improve the diagnostic tests used by laboratories and to increase the awareness of this disease among both clinicians and microbiologists. Our objective was to evaluate the impact of these efforts by assessing the current magnitude of underdiagnosis of CDI in Spain using two point-prevalence studies performed on one day each in January and July of 2013. A total of 111 Spanish laboratories selected all unformed stool specimens received for microbiological diagnosis on these days, and toxigenic culture was performed at a central reference laboratory. Toxigenic isolates were characterized both pheno- and genotypically. The reference laboratory detected 103 episodes of CDI in patients aged 2 years or more. Half (50.5 %) of the episodes were not diagnosed in the participating laboratories, owing to insensitive diagnostic tests (15.5 %) or the lack of clinical suspicion and request (35.0 %). The main ribotypes were 014, 078/126, 001/072, and 106. Ribotype 027 caused 2.9 % of all cases. Despite all the interventions undertaken, CDI remains a highly neglected disease because of the lack of sensitive diagnostic tests in some institutions and, especially, the absence of clinical suspicion, mainly in patients with community-associated CDI. Toxigenic C. difficile should be routinely sought in unformed stools sent for microbiological diagnosis, regardless of their origin.

  5. External quality assurance for HIV point-of-care testing in Africa: A collaborative country-partner approach to strengthen diagnostic services

    PubMed Central

    2016-01-01

    It is important to consider the role of diagnostics and the critical need for quality diagnostics services in resource-limited settings. Accurate diagnostic tests play a key role in patient management and the prevention and control of most infectious diseases. As countries plan for implementation of HIV early infant diagnosis and viral load point-of-care testing, the London School of Hygiene & Tropical Medicine has worked with countries and partners with an interest in external quality assurance to support quality point-of-care testing on the continent. Through a series of collaborative consultations and workshops, the London School of Hygiene & Tropical Medicine has gathered lessons learned, tools, and resources and developed quality assurance models that will support point-of-care testing. The London School of Hygiene & Tropical Medicine is committed to the continued advancement of laboratory diagnostics in Africa and quality laboratory services and point-of-care testing. PMID:28879132

  6. External Quality Assessment beyond the analytical phase: an Australian perspective.

    PubMed

    Badrick, Tony; Gay, Stephanie; McCaughey, Euan J; Georgiou, Andrew

    2017-02-15

    External Quality Assessment (EQA) is the verification, on a recurring basis, that laboratory results conform to expectations for the quality required for patient care. It is now widely recognised that both the pre- and post-laboratory phase of testing, termed the diagnostic phases, are a significant source of laboratory errors. These errors have a direct impact on both the effectiveness of the laboratory and patient safety. Despite this, Australian laboratories tend to be focussed on very narrow concepts of EQA, primarily surrounding test accuracy, with little in the way of EQA programs for the diagnostic phases. There is a wide range of possibilities for the development of EQA for the diagnostic phases in Australia, such as the utilisation of scenarios and health informatics. Such programs can also be supported through advances in health information and communications technology, including electronic test ordering and clinical decision support systems. While the development of such programs will require consultation and support from the referring doctors, and their format will need careful construction to ensure that the data collected is de-identified and provides education as well as useful and informative data, we believe that there is high value in the development of such programs. Therefore, it is our opinion that all pathology laboratories should strive to be involved in an EQA program in the diagnostic phases to both monitor the diagnostic process and to identify, learn from and reduce errors and near misses in these phases in a timely fashion.

  7. External Quality Assessment beyond the analytical phase: an Australian perspective

    PubMed Central

    Gay, Stephanie; McCaughey, Euan J.; Georgiou, Andrew

    2017-01-01

    External Quality Assessment (EQA) is the verification, on a recurring basis, that laboratory results conform to expectations for the quality required for patient care. It is now widely recognised that both the pre- and post-laboratory phase of testing, termed the diagnostic phases, are a significant source of laboratory errors. These errors have a direct impact on both the effectiveness of the laboratory and patient safety. Despite this, Australian laboratories tend to be focussed on very narrow concepts of EQA, primarily surrounding test accuracy, with little in the way of EQA programs for the diagnostic phases. There is a wide range of possibilities for the development of EQA for the diagnostic phases in Australia, such as the utilisation of scenarios and health informatics. Such programs can also be supported through advances in health information and communications technology, including electronic test ordering and clinical decision support systems. While the development of such programs will require consultation and support from the referring doctors, and their format will need careful construction to ensure that the data collected is de-identified and provides education as well as useful and informative data, we believe that there is high value in the development of such programs. Therefore, it is our opinion that all pathology laboratories should strive to be involved in an EQA program in the diagnostic phases to both monitor the diagnostic process and to identify, learn from and reduce errors and near misses in these phases in a timely fashion. PMID:28392728

  8. Pretest expectations strongly influence interpretation of abnormal laboratory results and further management

    PubMed Central

    2010-01-01

    Background Abnormal results of diagnostic laboratory tests can be difficult to interpret when disease probability is very low. Although most physicians generally do not use Bayesian calculations to interpret abnormal results, their estimates of pretest disease probability and reasons for ordering diagnostic tests may - in a more implicit manner - influence test interpretation and further management. A better understanding of this influence may help to improve test interpretation and management. Therefore, the objective of this study was to examine the influence of physicians' pretest disease probability estimates, and their reasons for ordering diagnostic tests, on test result interpretation, posttest probability estimates and further management. Methods Prospective study among 87 primary care physicians in the Netherlands who each ordered laboratory tests for 25 patients. They recorded their reasons for ordering the tests (to exclude or confirm disease or to reassure patients) and their pretest disease probability estimates. Upon receiving the results they recorded how they interpreted the tests, their posttest probability estimates and further management. Logistic regression was used to analyse whether the pretest probability and the reasons for ordering tests influenced the interpretation, the posttest probability estimates and the decisions on further management. Results The physicians ordered tests for diagnostic purposes for 1253 patients; 742 patients had an abnormal result (64%). Physicians' pretest probability estimates and their reasons for ordering diagnostic tests influenced test interpretation, posttest probability estimates and further management. Abnormal results of tests ordered for reasons of reassurance were significantly more likely to be interpreted as normal (65.8%) compared to tests ordered to confirm a diagnosis or exclude a disease (27.7% and 50.9%, respectively). The odds for abnormal results to be interpreted as normal were much lower when the physician estimated a high pretest disease probability, compared to a low pretest probability estimate (OR = 0.18, 95% CI = 0.07-0.52, p < 0.001). Conclusions Interpretation and management of abnormal test results were strongly influenced by physicians' estimation of pretest disease probability and by the reason for ordering the test. By relating abnormal laboratory results to their pretest expectations, physicians may seek a balance between over- and under-reacting to laboratory test results. PMID:20158908

  9. Pretest expectations strongly influence interpretation of abnormal laboratory results and further management.

    PubMed

    Houben, Paul H H; van der Weijden, Trudy; Winkens, Bjorn; Winkens, Ron A G; Grol, Richard P T M

    2010-02-16

    Abnormal results of diagnostic laboratory tests can be difficult to interpret when disease probability is very low. Although most physicians generally do not use Bayesian calculations to interpret abnormal results, their estimates of pretest disease probability and reasons for ordering diagnostic tests may--in a more implicit manner--influence test interpretation and further management. A better understanding of this influence may help to improve test interpretation and management. Therefore, the objective of this study was to examine the influence of physicians' pretest disease probability estimates, and their reasons for ordering diagnostic tests, on test result interpretation, posttest probability estimates and further management. Prospective study among 87 primary care physicians in the Netherlands who each ordered laboratory tests for 25 patients. They recorded their reasons for ordering the tests (to exclude or confirm disease or to reassure patients) and their pretest disease probability estimates. Upon receiving the results they recorded how they interpreted the tests, their posttest probability estimates and further management. Logistic regression was used to analyse whether the pretest probability and the reasons for ordering tests influenced the interpretation, the posttest probability estimates and the decisions on further management. The physicians ordered tests for diagnostic purposes for 1253 patients; 742 patients had an abnormal result (64%). Physicians' pretest probability estimates and their reasons for ordering diagnostic tests influenced test interpretation, posttest probability estimates and further management. Abnormal results of tests ordered for reasons of reassurance were significantly more likely to be interpreted as normal (65.8%) compared to tests ordered to confirm a diagnosis or exclude a disease (27.7% and 50.9%, respectively). The odds for abnormal results to be interpreted as normal were much lower when the physician estimated a high pretest disease probability, compared to a low pretest probability estimate (OR = 0.18, 95% CI = 0.07-0.52, p < 0.001). Interpretation and management of abnormal test results were strongly influenced by physicians' estimation of pretest disease probability and by the reason for ordering the test. By relating abnormal laboratory results to their pretest expectations, physicians may seek a balance between over- and under-reacting to laboratory test results.

  10. Diagnostic tests in HIV management: a review of clinical and laboratory strategies to monitor HIV-infected individuals in developing countries.

    PubMed Central

    Kimmel, April D.; Losina, Elena; Freedberg, Kenneth A.; Goldie, Sue J.

    2006-01-01

    We conducted a systematic review on the performance of diagnostic tests for clinical and laboratory monitoring of HIV-infected adults in developing countries. Diagnostic test information collected from computerized databases, bibliographies and the Internet were categorized as clinical (non-laboratory patient information), immunologic (information from immunologic laboratory tests), or virologic (information from virologic laboratory tests). Of the 51 studies selected for the review 28 assessed immunologic tests, 12 virologic tests and seven clinical and immunologic tests. Methods of performance evaluation were primarily sensitivity and specificity for the clinical category and correlation coefficients for immunologic and virologic categories. In the clinical category, the majority of test performance measures was reported as >70% sensitive and >65% specific. In the immunologic category, correlation coefficients ranged from r=0.54 to r=0.99 for different CD4 count enumeration techniques, while correlation for CD4 and total lymphocyte counts was between r=0.23 and r=0.74. In the virologic category, correlation coefficients for different human immunodeficiency virus (HIV) ribonucleic acid (RNA) quantification techniques ranged from r=0.54 to r=0.90. Future research requires consensus on designing studies, and collecting and reporting data useful for decision-makers. We recommend classifying information into clinically relevant categories, using a consistent definition of disease across studies and providing measures of both association and accuracy. PMID:16878233

  11. Diagnostic trends in Clostridium difficile detection in Finnish microbiology laboratories.

    PubMed

    Könönen, Eija; Rasinperä, Marja; Virolainen, Anni; Mentula, Silja; Lyytikäinen, Outi

    2009-12-01

    Due to increased interest directed to Clostridium difficile-associated infections, a questionnaire survey of laboratory diagnostics of toxin-producing C. difficile was conducted in Finland in June 2006. Different aspects pertaining to C. difficile diagnosis, such as requests and criteria used for testing, methods used for its detection, yearly changes in diagnostics since 1996, and the total number of investigations positive for C. difficile in 2005, were asked in the questionnaire, which was sent to 32 clinical microbiology laboratories, including all hospital-affiliated and the relevant private clinical microbiology laboratories in Finland. The situation was updated by phone and email correspondence in September 2008. In June 2006, 28 (88%) laboratories responded to the questionnaire survey; 24 of them reported routinely testing requested stool specimens for C. difficile. Main laboratory methods included toxin detection (21/24; 88%) and/or anaerobic culture (19/24; 79%). In June 2006, 18 (86%) of the 21 laboratories detecting toxins directly from feces, from the isolate, or both used methods for both toxin A (TcdA) and B (TcdB), whereas only one laboratory did so in 1996. By September 2008, all of the 23 laboratories performing diagnostics for C. difficile used methods for both TcdA and TcdB. In 2006, the number of specimens processed per 100,000 population varied remarkably between different hospital districts. In conclusion, culturing C. difficile is common and there has been a favorable shift in toxin detection practice in Finnish clinical microbiology laboratories. However, the variability in diagnostic activity reported in 2006 creates a challenge for national monitoring of the epidemiology of C. difficile and related diseases.

  12. Current Guidelines, Common Clinical Pitfalls, and Future Directions for Laboratory Diagnosis of Lyme Disease, United States.

    PubMed

    Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul; Schriefer, Martin

    2016-07-01

    In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%-40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%-100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics.

  13. The role of laboratory testing in detection and classification of chronic kidney disease: national recommendations

    PubMed Central

    Biljak, Vanja Radišić; Honović, Lorena; Matica, Jasminka; Krešić, Branka; Vojak, Sanela Šimić

    2017-01-01

    Chronic kidney disease (CKD) is a common clinical condition with significant adverse consequences for the patient and it is recognized as a significant public health problem. The role of laboratory medicine in diagnosis and management of CKD is of great importance: the diagnosis and staging are based on estimation of glomerular filtration rate (eGFR) and assessment of albuminuria (or proteinuria). Therefore, the joint working group of the Croatian society of medical biochemistry and laboratory medicine and Croatian chamber of medical biochemists for laboratory diagnostics in CKD issued this national recommendation regarding laboratory diagnostics of CKD.
Key factors for laboratories implementing the national guidelines for the diagnosis and management of CKD are:
1. Ensure good communication between laboratory professionals and clinicians, such as nephrologists or specialists in general/family medicine,
2. Ensure all patients are provided with the same availability of laboratory diagnostics,
3. Ensure creatinine assays are traceable to isotope dilution mass spectrometry (IDMS) method and have minimal bias and acceptable imprecision,
4. Select the appropriate GFR estimating formula. Recommended equation is the 2009 Chronic Kidney Disease Epidemiology Collaboration (CKD – EPI) equation,
5. In reporting the key laboratory tests (creatinine, eGFR, urine albumin-to-creatinine ratio, urine protein-to-creatinine ratio) use the appropriate reporting units,
6. Provide adequate information on limitations of creatinine measurement.
The manuscript has been organized to identify critical points in laboratory tests used in basic laboratory diagnostics of CKD and is based on the Kidney Disease: Improving Global Outcomes (KDIGO) 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease. PMID:28392738

  14. Missed diagnostic opportunities within South Africa's early infant diagnosis program, 2010-2015.

    PubMed

    Haeri Mazanderani, Ahmad; Moyo, Faith; Sherman, Gayle G

    2017-01-01

    Samples submitted for HIV PCR testing that fail to yield a positive or negative result represent missed diagnostic opportunities. We describe HIV PCR test rejections and indeterminate results, and the associated delay in diagnosis, within South Africa's early infant diagnosis (EID) program from 2010 to 2015. HIV PCR test data from January 2010 to December 2015 were extracted from the National Health Laboratory Service Corporate Data Warehouse, a central data repository of all registered test-sets within the public health sector in South Africa, by laboratory number, result, date, facility, and testing laboratory. Samples that failed to yield either a positive or negative result were categorized according to the rejection code on the laboratory information system, and descriptive analysis performed using Microsoft Excel. Delay in diagnosis was calculated for patients who had a missed diagnostic opportunity registered between January 2013 and December 2015 by means of a patient linking-algorithm employing demographic details. Between 2010 and 2015, 2 178 582 samples were registered for HIV PCR testing of which 6.2% (n = 134 339) failed to yield either a positive or negative result, decreasing proportionally from 7.0% (n = 20 556) in 2010 to 4.4% (n = 21 388) in 2015 (p<0.001). Amongst 76 972 coded missed diagnostic opportunities, 49 585 (64.4%) were a result of pre-analytical error and 27 387 (35.6%) analytical error. Amongst 49 694 patients searched for follow-up results, 16 895 (34.0%) had at least one subsequent HIV PCR test registered after a median of 29 days (IQR: 13-57), of which 8.4% tested positive compared with 3.6% of all samples submitted for the same period. Routine laboratory data provides the opportunity for near real-time surveillance and quality improvement within the EID program. Delay in diagnosis and wastage of resources associated with missed diagnostic opportunities must be addressed and infants actively followed-up as South Africa works towards elimination of mother-to-child transmission.

  15. Quantitative polymerase chain reaction (PCR) for detection of aquatic animal pathogens in a diagnostic laboratory setting

    USGS Publications Warehouse

    Purcell, Maureen K.; Getchell, Rodman G.; McClure, Carol A.; Weber, S.E.; Garver, Kyle A.

    2011-01-01

    Real-time, or quantitative, polymerase chain reaction (qPCR) is quickly supplanting other molecular methods for detecting the nucleic acids of human and other animal pathogens owing to the speed and robustness of the technology. As the aquatic animal health community moves toward implementing national diagnostic testing schemes, it will need to evaluate how qPCR technology should be employed. This review outlines the basic principles of qPCR technology, considerations for assay development, standards and controls, assay performance, diagnostic validation, implementation in the diagnostic laboratory, and quality assurance and control measures. These factors are fundamental for ensuring the validity of qPCR assay results obtained in the diagnostic laboratory setting.

  16. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.

    PubMed Central

    Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen

    2006-01-01

    OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726

  17. Roles of laboratories and laboratory systems in effective tuberculosis programmes

    PubMed Central

    van Deun, Armand; Kam, Kai Man; Narayanan, PR; Aziz, Mohamed Abdul

    2007-01-01

    Abstract Laboratories and laboratory networks are a fundamental component of tuberculosis (TB) control, providing testing for diagnosis, surveillance and treatment monitoring at every level of the health-care system. New initiatives and resources to strengthen laboratory capacity and implement rapid and new diagnostic tests for TB will require recognition that laboratories are systems that require quality standards, appropriate human resources, and attention to safety in addition to supplies and equipment. To prepare the laboratory networks for new diagnostics and expanded capacity, we need to focus efforts on strengthening quality management systems (QMS) through additional resources for external quality assessment programmes for microscopy, culture, drug susceptibility testing (DST) and molecular diagnostics. QMS should also promote development of accreditation programmes to ensure adherence to standards to improve both the quality and credibility of the laboratory system within TB programmes. Corresponding attention must be given to addressing human resources at every level of the laboratory, with special consideration being given to new programmes for laboratory management and leadership skills. Strengthening laboratory networks will also involve setting up partnerships between TB programmes and those seeking to control other diseases in order to pool resources and to promote advocacy for quality standards, to develop strategies to integrate laboratories’ functions and to extend control programme activities to the private sector. Improving the laboratory system will assure that increased resources, in the form of supplies, equipment and facilities, will be invested in networks that are capable of providing effective testing to meet the goals of the Global Plan to Stop TB. PMID:17639219

  18. Molecular pathology curriculum for medical laboratory scientists: A report of the association for molecular pathology training and education committee.

    PubMed

    Taylor, Sara; Bennett, Katie M; Deignan, Joshua L; Hendrix, Ericka C; Orton, Susan M; Verma, Shalini; Schutzbank, Ted E

    2014-05-01

    Molecular diagnostics is a rapidly growing specialty in the clinical laboratory assessment of pathology. Educational programs in medical laboratory science and specialized programs in molecular diagnostics must address the training of clinical scientists in molecular diagnostics, but the educational curriculum for this field is not well defined. Moreover, our understanding of underlying genetic contributions to specific diseases and the technologies used in molecular diagnostics laboratories change rapidly, challenging providers of training programs in molecular diagnostics to keep their curriculum current and relevant. In this article, we provide curriculum recommendations to molecular diagnostics training providers at both the baccalaureate and master's level of education. We base our recommendations on several factors. First, we considered National Accrediting Agency for Clinical Laboratory Sciences guidelines for accreditation of molecular diagnostics programs, because educational programs in clinical laboratory science should obtain its accreditation. Second, the guidelines of several of the best known certifying agencies for clinical laboratory scientists were incorporated into our recommendations. Finally, we relied on feedback from current employers of molecular diagnostics scientists, regarding the skills and knowledge that they believe are essential for clinical scientists who will be performing molecular testing in their laboratories. We have compiled these data into recommendations for a molecular diagnostics curriculum at both the baccalaureate and master's level of education. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  19. Wildlife specimen collection, preservation, and shipment

    USGS Publications Warehouse

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Prior to collecting samples, it is important to determine the capabilities and submission criteria of the laboratory receiving the samples. Some laboratories may specialize in a limited number of tests, be equipped to accept only certain types of tissues (instead of entire carcasses), or specialize in particular species or group of animals (e.g., reptiles, birds, mammals). Diagnostic laboratories have specific requirements regarding preparation, labeling, and shipping of samples. Adherence to these requirements helps ensure the usefulness of any submitted specimens. Although laboratories may vary in the cost and turnaround times for diagnostic tests, some laboratories may be able to prioritize samples and accommodate accelerated time frames if communicated at the time of submission. Keeping a prepacked kit with basic carcass-collection supplies, including a paper copy of the specimen history form (available for download from the Web sites of most diagnostic laboratories), in the office or vehicle will decrease the chances of forgetting an essential item and decrease response time for arriving at an event.

  20. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    PubMed

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  1. The demand for pregnancy testing: The Aschheim–Zondek reaction, diagnostic versatility, and laboratory services in 1930s Britain

    PubMed Central

    Olszynko-Gryn, Jesse

    2014-01-01

    The Aschheim–Zondek reaction is generally regarded as the first reliable hormone test for pregnancy and as a major product of the ‘heroic age’ of reproductive endocrinology. Invented in Berlin in the late 1920s, by the mid 1930s a diagnostic laboratory in Edinburgh was performing thousands of tests every year for doctors around Britain. In her classic history of antenatal care, sociologist Ann Oakley claimed that the Aschheim–Zondek test launched a ‘modern era’ of obstetric knowledge, which asserted its superiority over that of pregnant women. This article reconsiders Oakley’s claim by examining how pregnancy testing worked in practice. It explains the British adoption of the test in terms less of the medicalisation of pregnancy than of clinicians’ increasing general reliance on laboratory services for differential diagnosis. Crucially, the Aschheim–Zondek reaction was a test not directly for the fetus, but for placental tissue. It was used, less as a yes-or-no test for ordinary pregnancy, than as a versatile diagnostic tool for the early detection of malignant tumours and hormonal deficiencies believed to cause miscarriage. This test was as much a product of oncology and the little-explored world of laboratory services as of reproductive medicine. PMID:24388014

  2. Verification of performance specifications for a US Food and Drug Administration-approved molecular microbiology test: Clostridium difficile cytotoxin B using the Becton, Dickinson and Company GeneOhm Cdiff assay.

    PubMed

    Schlaberg, Robert; Mitchell, Michael J; Taggart, Edward W; She, Rosemary C

    2012-01-01

    US Food and Drug Administration (FDA)-approved diagnostic tests based on molecular genetic technologies are becoming available for an increasing number of microbial pathogens. Advances in technology and lower costs have moved molecular diagnostic tests formerly performed for research purposes only into much wider use in clinical microbiology laboratories. To provide an example of laboratory studies performed to verify the performance of an FDA-approved assay for the detection of Clostridium difficile cytotoxin B compared with the manufacturer's performance standards. We describe the process and protocols used by a laboratory for verification of an FDA-approved assay, assess data from the verification studies, and implement the assay after verification. Performance data from the verification studies conducted by the laboratory were consistent with the manufacturer's performance standards and the assay was implemented into the laboratory's test menu. Verification studies are required for FDA-approved diagnostic assays prior to use in patient care. Laboratories should develop a standardized approach to verification studies that can be adapted and applied to different types of assays. We describe the verification of an FDA-approved real-time polymerase chain reaction assay for the detection of a toxin gene in a bacterial pathogen.

  3. [Thalassaemia diagnostics].

    PubMed

    Kusters, Elske; Kerkhoffs, Jean-Louis H; van Rossum, André P

    2014-01-01

    The thalassaemias are characterised by quantitative aberrations in the production of the globin chains that make up haemoglobin, and are a subgroup of the haemoglobinopathies. In this LabQuiz we show how thalassaemia carrier status can be indicated in the results of regular laboratory tests, and discuss the laboratory diagnostics that can confirm or rule out thalassaemia. In these two cases we will present a man of Moroccan descent, and two brothers of Filipino descent, all with anaemia and microcytosis. We show it is possible to differentiate between iron-deficiency anaemia and thalassaemia carrier status on the basis of a complete blood count and measurement of ferritin levels, and which laboratory diagnostics can be subsequently performed in order to confirm a suspicion of thalassaemia. The background section discusses the properties and pitfalls of routine laboratory diagnostics for the thalassaemias, and thalassaemia diagnostics in the Dutch newborn screening programme.

  4. Interpretation of diagnostic data: 5. How to do it with simple maths.

    PubMed

    1983-11-01

    The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator.

  5. Interpretation of diagnostic data: 5. How to do it with simple maths.

    PubMed Central

    1983-01-01

    The use of simple maths with the likelihood ratio strategy fits in nicely with our clinical views. By making the most out of the entire range of diagnostic test results (i.e., several levels, each with its own likelihood ratio, rather than a single cut-off point and a single ratio) and by permitting us to keep track of the likelihood that a patient has the target disorder at each point along the diagnostic sequence, this strategy allows us to place patients at an extremely high or an extremely low likelihood of disease. Thus, the numbers of patients with ultimately false-positive results (who suffer the slings of labelling and the arrows of needless therapy) and of those with ultimately false-negative results (who therefore miss their chance for diagnosis and, possibly, efficacious therapy) will be dramatically reduced. The following guidelines will be useful in interpreting signs, symptoms and laboratory tests with the likelihood ratio strategy: Seek out, and demand from the clinical or laboratory experts who ought to know, the likelihood ratios for key symptoms and signs, and several levels (rather than just the positive and negative results) of diagnostic test results. Identify, when feasible, the logical sequence of diagnostic tests. Estimate the pretest probability of disease for the patient, and, using either the nomogram or the conversion formulas, apply the likelihood ratio that corresponds to the first diagnostic test result. While remembering that the resulting post-test probability or odds from the first test becomes the pretest probability or odds for the next diagnostic test, repeat the process for all the pertinent symptoms, signs and laboratory studies that pertain to the target disorder. However, these combinations may not be independent, and convergent diagnostic tests, if treated as independent, will combine to overestimate the final post-test probability of disease. You are now far more sophisticated in interpreting diagnostic tests than most of your teachers. In the last part of our series we will show you some rather complex strategies that combine diagnosis and therapy, quantify our as yet nonquantified ideas about use, and require the use of at least a hand calculator. PMID:6671182

  6. Laboratory diagnosis of Ebola virus disease and corresponding biosafety considerations in the China Ebola Treatment Center.

    PubMed

    Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing

    2016-10-01

    Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.

  7. Bottom-up or top-down: unit cost estimation of tuberculosis diagnostic tests in India.

    PubMed

    Rupert, S; Vassall, A; Raizada, N; Khaparde, S D; Boehme, C; Salhotra, V S; Sachdeva, K S; Nair, S A; Hoog, A H Van't

    2017-04-01

    Of 18 sites that participated in an implementation study of the Xpert® MTB/RIF assay in India, we selected five microscopy centres and two reference laboratories. To obtain unit costs of diagnostic tests for tuberculosis (TB) and drug-resistant TB. Laboratories were purposely selected to capture regional variations and different laboratory types. Both bottom-up and the top-down methods were used to estimate unit costs. At the microscopy centres, mean bottom-up unit costs were respectively US$0.83 (range US$0.60-US$1.10) and US$12.29 (US$11.61-US$12.89) for sputum smear microscopy and Xpert. At the reference laboratories, mean unit costs were US$1.69 for the decontamination procedure, US$9.83 for a solid culture, US$11.06 for a liquid culture, US$29.88 for a drug susceptibility test, and US$18.18 for a line-probe assay. Top-down mean unit cost estimates were higher for all tests, and for sputum smear microscopy and Xpert these increased to respectively US$1.51 and US$13.58. The difference between bottom-up and top-down estimates was greatest for tests performed at the reference laboratories. These unit costs for TB diagnostics can be used to estimate resource requirements and cost-effectiveness in India, taking into account geographical location, laboratory type and capacity utilisation.

  8. A UK NEQAS ICC and ISH multicentre study using the Kreatech Poseidon HER2 FISH probe: intersite variation can be rigorously controlled using FISH.

    PubMed

    Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith

    2010-02-01

    To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.

  9. Phosphorus blood test

    MedlinePlus

    ... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:878-880. Klemm ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 15. Kliegman RM, ...

  10. Comparison of species-level identification and antifungal susceptibility results from diagnostic and reference laboratories for bloodstream Candida surveillance isolates, South Africa, 2009-2010.

    PubMed

    Naicker, Serisha D; Govender, Nevashan; Patel, Jaymati; Zietsman, Inge L; Wadula, Jeannette; Coovadia, Yacoob; Kularatne, Ranmini; Seetharam, Sharona; Govender, Nelesh P

    2016-11-01

    From February 2009 through August 2010, we compared species-level identification of bloodstream Candida isolates and susceptibility to fluconazole, voriconazole, and caspofungin between diagnostic and reference South African laboratories during national surveillance for candidemia. Diagnostic laboratories identified isolates to genus/species level and performed antifungal susceptibility testing, as indicated. At a reference laboratory, viable Candida isolates were identified to species-level using automated systems, biochemical tests, or DNA sequencing; broth dilution susceptibility testing was performed. Categorical agreement (CA) was calculated for susceptibility results of isolates with concordant species identification. Overall, 2172 incident cases were detected, 773 (36%) by surveillance audit. The Vitek 2 YST system (bioMérieux Inc, Marcy l'Etoile, France) was used for identification (360/863, 42%) and susceptibility testing (198/473, 42%) of a large proportion of isolates. For the five most common species (n = 1181), species-level identification was identical in the majority of cases (Candida albicans: 98% (507/517); Candida parapsilosis: 92% (450/488); Candida glabrata: 89% (89/100); Candida tropicalis: 91% (49/54), and Candida krusei: 86% (19/22)). However, diagnostic laboratories were significantly less likely to correctly identify Candida species other than C. albicans versus C. albicans (607/664, 91% vs. 507/517, 98%; P < .001). Susceptibility data were compared for isolates belonging to the five most common species and fluconazole, voriconazole, and caspofungin in 860, 580, and 99 cases, respectively. Diagnostic laboratories significantly under-reported fluconazole resistance in C. parapsilosis (225/393, 57% vs. 239/393, 61%; P < .001) but over-reported fluconazole non-susceptibility in C. albicans (36/362, 10% vs. 3/362, 0.8%; P < .001). Diagnostic laboratories were less likely to correctly identify Candida species other than C. albicans, under-reported fluconazole resistance for C. parapsilosis and over-reported fluconazole resistance for C. albicans. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. A Gram Stain Hands-On Workshop Enhances First Year Medical Students' Technique Competency in Comprehension and Memorization.

    PubMed

    Delfiner, Matthew S; Martinez, Luis R; Pavia, Charles S

    2016-01-01

    Laboratory diagnostic tests have an essential role in patient care, and the increasing number of medical and health professions schools focusing on teaching laboratory medicine to pre-clinical students reflects this importance. However, data validating the pedagogical methods that best influence students' comprehension and interpretation of diagnostic tests have not been well described. The Gram stain is a simple yet significant and frequently used diagnostic test in the clinical setting that helps classify bacteria into two major groups, Gram positive and negative, based on their cell wall structure. We used this technique to assess which educational strategies may improve students' learning and competency in medical diagnostic techniques. Hence, in this randomized controlled study, we compared the effectiveness of several educational strategies (e.g. workshop, discussion, or lecture) in first year medical students' competency in comprehension and interpretation of the Gram stain procedure. We demonstrated that a hands-on practical workshop significantly enhances students' competency in memorization and overall comprehension of the technique. Interestingly, most students irrespective of their cohort showed difficulty in answering Gram stain-related analytical questions, suggesting that more emphasis should be allocated by the instructors to clearly explain the interpretation of the diagnostic test results to students in medical and health professional schools. This proof of principle study highlights the need of practical experiences on laboratory medical techniques during pre-clinical training to facilitate future medical doctors' and healthcare professionals' basic understanding and competency in diagnostic testing for better patient care.

  12. Antidiuretic hormone blood test

    MedlinePlus

    ... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:146. Guber HA, ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 24. Oh MS, ...

  13. Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, James H.

    2005-01-01

    An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.

  14. Compounding diagnostic delays: a qualitative study of point-of-care testing in South Africa.

    PubMed

    Engel, Nora; Davids, Malika; Blankvoort, Nadine; Pai, Nitika Pant; Dheda, Keertan; Pai, Madhukar

    2015-04-01

    Successful point-of-care (POC) testing (completion of test-and-treat cycle in one patient encounter) has immense potential to reduce diagnostic and treatment delays, and improve patient and public health outcomes. We explored what tests are done and how in public/private, rural/urban hospitals and clinics in South Africa and whether they can ensure successful POC testing. This qualitative research study examined POC testing across major diseases in Cape Town, Durban and Eastern Cape. We conducted 101 semi-structured interviews and seven focus group discussions with doctors, nurses, community health workers, patients, laboratory technicians, policymakers, hospital managers and diagnostic manufacturers. In South Africa, diagnostics are characterised by a centralised system. Most tests conducted on the spot can be made to work successfully as POC tests. The majority of public/private clinics and smaller hospitals send samples via couriers to centralised laboratories and retrieve results the same way, via internet, fax or phone. The main challenge to POC testing lies in transporting samples and results, while delays risk patient loss from diagnostic/treatment pathways. Strategies to deal with associated delays create new problems, such as artificially prolonged turnaround times, strains on human resources and quality of testing, compounding additional diagnostic and treatment delays. For POC testing to succeed, particular characteristics of diagnostic ecosystems and adaptations of professional practices to overcome associated challenges must be taken into account. © 2014 John Wiley & Sons Ltd.

  15. Integration of Diagnostic Microbiology in a Model of Total Laboratory Automation.

    PubMed

    Da Rin, Giorgio; Zoppelletto, Maira; Lippi, Giuseppe

    2016-02-01

    Although automation has become widely utilized in certain areas of diagnostic testing, its adoption in diagnostic microbiology has proceeded much more slowly. To describe our real-world experience of integrating an automated instrument for diagnostic microbiology (Walk-Away Specimen Processor, WASPLab) within a model of total laboratory automation (TLA). The implementation process was divided into 2 phases. The former period, lasting approximately 6 weeks, entailed the installation of the WASPLab processor to operate as a stand-alone instrumentation, whereas the latter, lasting approximately 2 weeks, involved physical connection of the WASPLab with the automation. Using the WASPLab instrument in conjunction with the TLA model, we obtained a time savings equivalent to the work of 1.2 full-time laboratory technicians for diagnostic microbiology. The connection of WASPLab to TLA allowed its management by a generalist or clinical chemistry technician, with no need for microbiology skills on the part of either worker. Hence, diagnostic microbiology could be performed by the staff that is already using the TLA, extending their activities to include processing urgent clinical chemistry and hematology specimens. The time to result was also substantially improved. According to our experience, using the WASPLab instrument as part of a TLA in diagnostic microbiology holds great promise for optimizing laboratory workflow and improving the quality of testing. © American Society for Clinical Pathology, 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Diagnosis of Ebola Virus Disease: Past, Present, and Future

    PubMed Central

    Brooks, Tim J. G.

    2016-01-01

    SUMMARY Laboratory diagnosis of Ebola virus disease plays a critical role in outbreak response efforts; however, establishing safe and expeditious testing strategies for this high-biosafety-level pathogen in resource-poor environments remains extremely challenging. Since the discovery of Ebola virus in 1976 via traditional viral culture techniques and electron microscopy, diagnostic methodologies have trended toward faster, more accurate molecular assays. Importantly, technological advances have been paired with increasing efforts to support decentralized diagnostic testing capacity that can be deployed at or near the point of patient care. The unprecedented scope of the 2014-2015 West Africa Ebola epidemic spurred tremendous innovation in this arena, and a variety of new diagnostic platforms that have the potential both to immediately improve ongoing surveillance efforts in West Africa and to transform future outbreak responses have reached the field. In this review, we describe the evolution of Ebola virus disease diagnostic testing and efforts to deploy field diagnostic laboratories in prior outbreaks. We then explore the diagnostic challenges pervading the 2014-2015 epidemic and provide a comprehensive examination of novel diagnostic tests that are likely to address some of these challenges moving forward. PMID:27413095

  17. [Assessment of a rapid diagnostic test and portable fluorescent microscopy for malaria diagnosis in Cotonou (Bénin)].

    PubMed

    Ogouyèmi-Hounto, A; Kinde-Gazard, D; Keke, C; Gonçalves, E; Alapini, N; Adjovi, F; Adisso, L; Bossou, C; Denon, Y V; Massougbodji, A

    2013-02-01

    The aim of the study was to determine the accuracy of a rapid diagnostic test (SD Bioline Malaria Ag P.f/ Pan®) and fluorescent microscopy (CyScope®) in confirming presumptive malaria diagnosis in Cotonou. Thick blood smear was used as the reference technique for comparison. Testing was conducted on persons between the ages of 6 months and 70 years at two hospitals from June to October 2010. If malaria was suspected in the sample by the nurse based on clinical findings and sent to laboratory for confirmation, one thick smear, one rapid diagnostic test and one slide for the fluorescent microscopy were performed. All tests were read in hospital laboratories involved with the quality control of thick blood smear in the parasitology laboratory of National University Hospital of Cotonou. A total of 354 patients with clinical diagnosis of malaria were included. Malaria prevalence determined by thick smear, rapid diagnostic test and fluorescent microscopy was 22.8%, 25.4%, and 25.1% respectively. The sensitivity, specificity, positive and negative predictive values compared to the thick smears were 96.3, 95.6, 86.7, and 98.9% for rapid diagnostic test; and 97.5, 96.7, 89.8, and 99.27% for fluorescent microscopy. With these performances, these tests meet acceptability standards recommended by WHO for rapid tests (sensitivity > 95%). These two methods have advantages for the confirmation of malaria diagnosis in peripheral health structures that lack the resources to conduct diagnosis confirmation by the thick blood smear.

  18. Reagent and labor cost optimization through automation of fluorescence in situ hybridization (FISH) with the VP 2000: an Italian case study.

    PubMed

    Zanatta, Lucia; Valori, Laura; Cappelletto, Eleonora; Pozzebon, Maria Elena; Pavan, Elisabetta; Dei Tos, Angelo Paolo; Merkle, Dennis

    2015-02-01

    In the modern molecular diagnostic laboratory, cost considerations are of paramount importance. Automation of complex molecular assays not only allows a laboratory to accommodate higher test volumes and throughput but also has a considerable impact on the cost of testing from the perspective of reagent costs, as well as hands-on time for skilled laboratory personnel. The following study tracked the cost of labor (hands-on time) and reagents for fluorescence in situ hybridization (FISH) testing in a routine, high-volume pathology and cytogenetics laboratory in Treviso, Italy, over a 2-y period (2011-2013). The laboratory automated FISH testing with the VP 2000 Processor, a deparaffinization, pretreatment, and special staining instrument produced by Abbott Molecular, and compared hands-on time and reagent costs to manual FISH testing. The results indicated significant cost and time saving when automating FISH with VP 2000 when more than six FISH tests were run per week. At 12 FISH assays per week, an approximate total cost reduction of 55% was observed. When running 46 FISH specimens per week, the cost saving increased to 89% versus manual testing. The results demonstrate that the VP 2000 processor can significantly reduce the cost of FISH testing in diagnostic laboratories. © 2014 Society for Laboratory Automation and Screening.

  19. The level of laboratory testing required for diagnosis or exclusion of a platelet function disorder using platelet aggregation and secretion assays.

    PubMed

    Mezzano, Diego; Quiroga, Teresa; Pereira, Jaime

    2009-03-01

    The major advances from research on platelet molecular and cell biology, physiology, and pathophysiology over the past decades have not been adequately translated to clinical laboratory diagnosis. Hereditary platelet function disorders (PFDs) are at least as prevalent in the general population as von Willebrand disease (VWD) although PFDs tend not be as well recognized or evaluated. Clinical mucous and skin bleeding in patients with PFDs is prototypic of primary hemostasis disorders, and the bleeding pattern is not distinguishable from that of other primary hemostasis disorders such as VWD. However, different treatment needs, between these discrete disorders, make a precise diagnosis mandatory. Currently, clinicians receive reliable laboratory reports when testing patients with severe PFDs, such as Glanzmann thrombasthenia and Bernard-Soulier syndrome, due to the distinctive laboratory defects that these disorders present, together with the availability of differential diagnostic tests. This is not the case for the majority of PFDs generically classified as "platelet secretion disorders," which are a heterogeneous group of "mild bleeding disorders," for which there are not universally accepted diagnostic criteria. An important reason for robust diagnostic tests is the high proportion (more than 50% in some reports) of patients with unequivocal bleeding who have no precise diagnosis established after a complete laboratory workup. It is paradoxical that the current "gold standard" test for PFD diagnosis, light transmission aggregometry (LTA), has not been standardized after more than four decades of worldwide clinical use. This review describes current diagnostic assays for PFD in a clinical hemostasis laboratory, relating these with current knowledge on platelet function and pathophysiology. Special emphasis will be given to LTA and platelet secretion tests, as well as to the reasons why sensitive tests are needed to explore the lesser known participation of platelets in blood clotting and fibrinolytic processes.

  20. Evaluation of Commercially Available Diagnostic Tests for the Detection of Dengue Virus NS1 Antigen and Anti-Dengue Virus IgM Antibody

    PubMed Central

    Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.

    2014-01-01

    Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157

  1. Self-Reported HIV-Positive Status But Subsequent HIV-Negative Test Result Using Rapid Diagnostic Testing Algorithms Among Seven Sub-Saharan African Military Populations

    DTIC Science & Technology

    2017-07-07

    RESEARCH ARTICLE Self-reported HIV-positive status but subsequent HIV-negative test result using rapid diagnostic testing algorithms among seven sub...America * judith.harbertson.ctr@mail.mil Abstract HIV rapid diagnostic tests (RDTs) combined in an algorithm are the current standard for HIV diagnosis...in many sub-Saharan African countries, and extensive laboratory testing has con- firmed HIV RDTs have excellent sensitivity and specificity. However

  2. Current Guidelines, Common Clinical Pitfalls, and Future Directions for Laboratory Diagnosis of Lyme Disease, United States

    PubMed Central

    Moore, Andrew; Nelson, Christina; Molins, Claudia; Mead, Paul

    2016-01-01

    In the United States, Lyme disease is caused by Borrelia burgdorferi and transmitted to humans by blacklegged ticks. Patients with an erythema migrans lesion and epidemiologic risk can receive a diagnosis without laboratory testing. For all other patients, laboratory testing is necessary to confirm the diagnosis, but proper interpretation depends on symptoms and timing of illness. The recommended laboratory test in the United States is 2-tiered serologic analysis consisting of an enzyme-linked immunoassay or immunofluorescence assay, followed by reflexive immunoblotting. Sensitivity of 2-tiered testing is low (30%–40%) during early infection while the antibody response is developing (window period). For disseminated Lyme disease, sensitivity is 70%–100%. Specificity is high (>95%) during all stages of disease. Use of other diagnostic tests for Lyme disease is limited. We review the rationale behind current US testing guidelines, appropriate use and interpretation of tests, and recent developments in Lyme disease diagnostics. PMID:27314832

  3. Association of Reference Pricing for Diagnostic Laboratory Testing With Changes in Patient Choices, Prices, and Total Spending for Diagnostic Tests.

    PubMed

    Robinson, James C; Whaley, Christopher; Brown, Timothy T

    2016-09-01

    Prices for laboratory and other clinical services vary widely. Employers and insurers increasingly are adopting "reference pricing" policies to create incentives for patients to select lower-priced facilities. To measure the association between implementation of reference pricing and patient choice of laboratory, test prices, patient out-of-pocket spending, and insurer spending. We conducted an observational study of changes in laboratory pricing and selection by employees of a large national grocery firm (n = 30 415) before and after the firm implemented a reference pricing policy for laboratory services and compared the findings with changes over the same period for policy holders of a large national insurer that did not implement reference pricing (n = 181 831). The grocery firm established a maximum payment limit at the 60th percentile of the distribution of prices for each laboratory test in each region. Employees were provided with data on prices at all laboratories through a mobile digital platform. Patients selecting a laboratory that charged more than the payment limit were required to pay the full difference themselves. A total of 2.13 million claims were analyzed for 285 types of in vitro diagnostic tests between 2010 and 2013. Patient choice of laboratory, price paid per test, patient out-of-pocket costs, and employer spending. Compared with trends in prices paid by insurance policy holders not subject to reference pricing, and after adjusting for characteristics of tests and patients, implementation of reference pricing was associated with a 31.9% reduction (95% CI, 20.6%-41.6%) in average price paid per test by the third year of the program. In these 3 years, total spending on laboratory tests declined by $2.57 million (95% CI, $1.59-$3.35 million). Out-of-pocket costs by patients declined by $1.05 million (95% CI, $0.73-$1.37 million). Spending by the employer declined by $1.70 million (95% CI, $0.92-$2.48 million). When combined with access to price information, reference pricing was associated with patient choice of lower-cost laboratories and reductions in prices and payments by both employer and employees.

  4. Antimicrobial Susceptibility Testing, Drug Resistance Mechanisms, and Therapy of Infections with Nontuberculous Mycobacteria

    PubMed Central

    Nash, Kevin A.; Wallace, Richard J.

    2012-01-01

    Summary: Within the past 10 years, treatment and diagnostic guidelines for nontuberculous mycobacteria have been recommended by the American Thoracic Society (ATS) and the Infectious Diseases Society of America (IDSA). Moreover, the Clinical and Laboratory Standards Institute (CLSI) has published and recently (in 2011) updated recommendations including suggested antimicrobial and susceptibility breakpoints. The CLSI has also recommended the broth microdilution method as the gold standard for laboratories performing antimicrobial susceptibility testing of nontuberculous mycobacteria. This article reviews the laboratory, diagnostic, and treatment guidelines together with established and probable drug resistance mechanisms of the nontuberculous mycobacteria. PMID:22763637

  5. Economic challenges associated with tuberculosis diagnostic development

    PubMed Central

    Hanrahan, Colleen F.; Shah, Maunank

    2015-01-01

    Tuberculosis remains a global health crisis in part due to underdiagnosis. Technological innovations are needed to improve diagnostic test accuracy and reduce the reliance on expensive laboratory infrastructure. However, there are significant economic challenges impeding the development and implementation of new diagnostics. The aim of this piece is to examine the current state of TB diagnostics, outline the unmet needs for new tests, and detail the economic challenges associated with development of new tests from the perspective of developers, policy makers and implementers. PMID:24766367

  6. Economic challenges associated with tuberculosis diagnostic development.

    PubMed

    Hanrahan, Colleen F; Shah, Maunank

    2014-08-01

    Tuberculosis remains a global health crisis in part due to underdiagnosis. Technological innovations are needed to improve diagnostic test accuracy and reduce the reliance on expensive laboratory infrastructure. However, there are significant economic challenges impeding the development and implementation of new diagnostics. The aim of this piece is to examine the current state of TB diagnostics, outline the unmet needs for new tests, and detail the economic challenges associated with development of new tests from the perspective of developers, policy makers and implementers.

  7. A Study on the Effects of Sympathetic Skin Response Parameters in Diagnosis of Fibromyalgia Using Artificial Neural Networks.

    PubMed

    Ozkan, Ozhan; Yildiz, Murat; Arslan, Evren; Yildiz, Sedat; Bilgin, Suleyman; Akkus, Selami; Koyuncuoglu, Hasan R; Koklukaya, Etem

    2016-03-01

    Fibromyalgia syndrome (FMS), usually observed commonly in females over age 30, is a rheumatic disease accompanied by extensive chronic pain. In the diagnosis of the disease non-objective psychological tests and physiological tests and laboratory test results are evaluated and clinical experiences stand out. However, these tests are insufficient in differentiating FMS with similar diseases that demonstrate symptoms of extensive pain. Thus, objective tests that would help the diagnosis are needed. This study analyzes the effect of sympathetic skin response (SSR) parameters on the auxiliary tests used in FMS diagnosis, the laboratory tests and physiological tests. The study was conducted in Suleyman Demirel University, Faculty of Medicine, Physical Medicine and Rehabilitation Clinic in Turkey with 60 patients diagnosed with FMS for the first time and a control group of 30 healthy individuals. In the study all participants underwent laboratory tests (blood tests), certain physiological tests (pulsation, skin temperature, respiration) and SSR measurements. The test data and SSR parameters obtained were classified using artificial neural network (ANN). Finally, in the ANN framework, where only laboratory and physiological test results were used as input, a simulation result of 96.51 % was obtained, which demonstrated diagnostic accuracy. This data, with the addition of SSR parameter values obtained increased to 97.67 %. This result including SSR parameters - meaning a higher diagnostic accuracy - demonstrated that SSR could be a new auxillary diagnostic method that could be used in the diagnosis of FMS.

  8. Concordance in diagnostic testing for respiratory pathogens of Bighorn Sheep

    USDA-ARS?s Scientific Manuscript database

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack ...

  9. Implementation of Rapid Molecular Infectious Disease Diagnostics: the Role of Diagnostic and Antimicrobial Stewardship.

    PubMed

    Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R

    2017-03-01

    New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics. Copyright © 2017 American Society for Microbiology.

  10. Ham test

    MedlinePlus

    Acid hemolysin test; Paroxysmal nocturnal hemoglobinuria - Ham test; PNH - Ham test ... BJ. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. Philadelphia, PA: Elsevier ...

  11. The impact of commercial rapid respiratory virus diagnostic tests on patient outcomes and health system utilization.

    PubMed

    Ko, Fiona; Drews, Steven J

    2017-10-01

    Acute respiratory tract infections due to influenza A/B and respiratory syncytial virus (RSV) are major causes of morbidity and mortality globally. Rapid tests for detection of these pathogens include antigen detection point of care tests (POC) and newer easy to use molecular tests. From experience, these assays improve both laboratory workflow and assay interpretation issues. However, the question of the benefits of using rapid test technology compared to routine laboratory testing for respiratory viral pathogens is still often asked. Areas covered: Specifically, this review aims to; 1) identify clinical/patient indicators that can be measured prior to and following the implementation of rapid diagnostic test for influenza and RSV, 2) provide multiple perspectives on the extent of impact of a rapid diagnostic test, including direct and indirect outcomes, and 3) identify the technological advancements in the development of rapid testing, demonstrating a timeline that transitions from antigen-based assays to molecular assays. Expert commentary: Key benefits to the use of either antigen-based or molecular rapid tests for patient care, patient flow within institutions, as well as laboratory utilization are identified. Due to improved test characteristics, the authors feel that rapid molecular tests have greater benefits than antigen-based detection methods.

  12. Multiplex molecular testing for management of infectious gastroenteritis in a hospital setting: a comparative diagnostic and clinical utility study.

    PubMed

    Halligan, E; Edgeworth, J; Bisnauthsing, K; Bible, J; Cliff, P; Aarons, E; Klein, J; Patel, A; Goldenberg, S

    2014-08-01

    Laboratory diagnosis and clinical management of inpatients with diarrhoea is complex and time consuming. Tests are often requested sequentially and undertaken in different laboratories. This causes prolonged unnecessary presumptive isolation of patients, because most cases are non-infectious. A molecular multiplex test (Luminex(®) Gastrointestinal Pathogen Panel (GPP)) was compared with conventional testing over 8 months to determine diagnostic accuracy, turnaround times, laboratory costs, use of isolation facilities and user acceptability. A total of 262 (12%) patients had a pathogen detected by conventional methods compared with 483 (22.1%) by GPP. Most additional cases were detected in patients developing symptoms in the first 4 days of admission. Additional cases were detected because of presumed improved diagnostic sensitivity but also because clinicians had not requested the correct pathogen. Turnaround time (41.8 h) was faster than bacterial culture (66.5 h) and parasite investigation (66.5 h) but slower than conventional testing for Clostridium difficile (17.3 h) and viruses (27 h). The test could allow simplified requesting by clinicians and a consolidated laboratory workflow, reducing the overall number of specimens received by the laboratory. A total of 154 isolation days were saved at an estimated cost of £30 800. Consumables and labour were estimated at £150 641 compared with £63 431 for conventional testing. Multiplex molecular testing using a panel of targets allowed enhanced detection and a consolidated laboratory workflow. This is likely to be of greater benefit to cases that present within the first 4 days of hospital admission. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  13. Initial Public Health Laboratory Response After Hurricane Maria - Puerto Rico, 2017.

    PubMed

    Concepción-Acevedo, Jeniffer; Patel, Anita; Luna-Pinto, Carolina; Peña, Rafael González; Cuevas Ruiz, Rosa Ivette; Arbolay, Héctor Rivera; Toro, Mayra; Deseda, Carmen; De Jesus, Victor R; Ribot, Efrain; Gonzalez, Jennifer-Quiñones; Rao, Gouthami; De Leon Salazar, Alfonsina; Ansbro, Marisela; White, Brunilís B; Hardy, Margaret C; Georgi, Joaudimir Castro; Stinnett, Rita; Mercante, Alexandra M; Lowe, David; Martin, Haley; Starks, Angela; Metchock, Beverly; Johnston, Stephanie; Dalton, Tracy; Joglar, Olga; Stafford, Cortney; Youngblood, Monica; Klein, Katherine; Lindstrom, Stephen; Berman, LaShondra; Galloway, Renee; Schafer, Ilana J; Walke, Henry; Stoddard, Robyn; Connelly, Robin; McCaffery, Elaine; Rowlinson, Marie-Claire; Soroka, Stephen; Tranquillo, Darin T; Gaynor, Anne; Mangal, Chris; Wroblewski, Kelly; Muehlenbachs, Atis; Salerno, Reynolds M; Lozier, Matthew; Sunshine, Brittany; Shapiro, Craig; Rose, Dale; Funk, Renee; Pillai, Satish K; O'Neill, Eduardo

    2018-03-23

    Hurricane Maria made landfall in Puerto Rico on September 20, 2017, causing major damage to infrastructure and severely limiting access to potable water, electric power, transportation, and communications. Public services that were affected included operations of the Puerto Rico Department of Health (PRDOH), which provides critical laboratory testing and surveillance for diseases and other health hazards. PRDOH requested assistance from CDC for the restoration of laboratory infrastructure, surveillance capacity, and diagnostic testing for selected priority diseases, including influenza, rabies, leptospirosis, salmonellosis, and tuberculosis. PRDOH, CDC, and the Association of Public Health Laboratories (APHL) collaborated to conduct rapid needs assessments and, with assistance from the CDC Foundation, implement a temporary transport system for shipping samples from Puerto Rico to the continental United States for surveillance and diagnostic and confirmatory testing. This report describes the initial laboratory emergency response and engagement efforts among federal, state, and nongovernmental partners to reestablish public health laboratory services severely affected by Hurricane Maria. The implementation of a sample transport system allowed Puerto Rico to reinitiate priority infectious disease surveillance and laboratory testing for patient and public health interventions, while awaiting the rebuilding and reinstatement of PRDOH laboratory services.

  14. The importance of quality assurance/quality control of diagnostics to increase the confidence in global foot-and-mouth disease control.

    PubMed

    De Clercq, K; Goris, N; Barnett, P V; MacKay, D K

    2008-01-01

    The last decade international trade in animals and animal products was liberated and confidence in this global trade can increase only if appropriate control measures are applied. As foot-and-mouth disease (FMD) diagnostics will play an essential role in this respect, the Food and Agriculture Organization European Commission for the Control of Foot-and-Mouth Disease (EUFMD) co-ordinates, in collaboration with the European Commission, several programmes to increase the quality of FMD diagnostics. A quality assurance (QA) system is deemed essential for laboratories involved in certifying absence of FMDV or antibodies against the virus. Therefore, laboratories are encouraged to validate their diagnostic tests fully and to install a continuous quality control (QC) monitoring system. Knowledge of performance characteristics of diagnostics is essential to interpret results correctly and to calculate sample rates in regional surveillance campaigns. Different aspects of QA/QC of classical and new FMD virological and serological diagnostics are discussed in respect to the EU FMD directive (2003/85/EC). We recommended accepting trade certificates only from laboratories participating in international proficiency testing on a regular basis.

  15. The future of hospital laboratories. Position statement from the Royal Belgian Society of Clinical Chemistry (RBSCC).

    PubMed

    Langlois, Michel R; Wallemacq, Pierre

    2009-01-01

    To face the economic pressures arising from the current socio-economic conjuncture, hospital laboratories are endangered by an increasing trend towards the outsourcing of clinical laboratory tests to external (mega-) laboratories. This should allow hospitals to meet their economic requirements, but with an increased risk of loss of medical quality and, mid- to long-term, loss of cost effectiveness of healthcare at the national level. To anticipate current developments (economical and technological) that inevitably will affect the future of laboratory medicine, hospital laboratories should be proactive and enhance efficiency, reduce costs by consolidation, integrate into regional networks, and form alliances or partnerships. To create additional value, the core competency of laboratory professionals must be refocused to provide medical knowledge services (consultative support to clinicians) related to in vitro diagnostic testing. To integrate cost-efficiency with medical quality, implementation of a matricial organization - operational vs. biomedical level - could be an interesting approach. This integrated structure should create total quality of laboratory testing, managing the entire medical diagnostic cycle from the pre-preanalytical to post-postanalytical phase.

  16. 42 CFR 414.510 - Laboratory date of service for clinical laboratory and pathology specimens.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Laboratory date of service for clinical laboratory... AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.510 Laboratory date of service for clinical laboratory and pathology specimens. The date of service for either a...

  17. [An evaluation of the effectiveness of laboratory diagnostic methods for brucellosis].

    PubMed

    Gandara, B; Zheludkov, M M; Chernysheva, M I

    1994-01-01

    The diagnostic value of bacteriological and serological methods for the laboratory diagnosis of brucellosis was studied. In the analysis of milk and cheese specimens Brucella cultures were isolated and differentiated as B.melitensis, biovar I, and B.abortus, biovar 4. In 25.6% of cases B.melitensis culture, biovar 1, was isolated from the blood of persons suspected for brucellosis. The isolation of B.melitensis culture from milk showed that this infective agent migrated from small animals to cattle, which was indicative of a high risk of human infection in the state of Zacatecas, Mexico. The comparative evaluation of serological diagnostic methods (the agglutination test in test tubes, Huddleson's slide test, the acidic rose bengal test and the 2-mercaptoethanol test) showed high sensitivity of rapid tests (Huddleson's test and the rose bengal test in 93.7% and 87.9% of cases respectively). The 2-mercaptoethanol test which gave positive results in 63.8% of cases provided additional information characterizing the course of infections process.

  18. European specialist porphyria laboratories: diagnostic strategies, analytical quality, clinical interpretation, and reporting as assessed by an external quality assurance program.

    PubMed

    Aarsand, Aasne K; Villanger, Jørild H; Støle, Egil; Deybach, Jean-Charles; Marsden, Joanne; To-Figueras, Jordi; Badminton, Mike; Elder, George H; Sandberg, Sverre

    2011-11-01

    The porphyrias are a group of rare metabolic disorders whose diagnosis depends on identification of specific patterns of porphyrin precursor and porphyrin accumulation in urine, blood, and feces. Diagnostic tests for porphyria are performed by specialized laboratories in many countries. Data regarding the analytical and diagnostic performance of these laboratories are scarce. We distributed 5 sets of multispecimen samples from different porphyria patients accompanied by clinical case histories to 18-21 European specialist porphyria laboratories/centers as part of a European Porphyria Network organized external analytical and postanalytical quality assessment (EQA) program. The laboratories stated which analyses they would normally have performed given the case histories and reported results of all porphyria-related analyses available, interpretative comments, and diagnoses. Reported diagnostic strategies initially showed considerable diversity, but the number of laboratories applying adequate diagnostic strategies increased during the study period. We found an average interlaboratory CV of 50% (range 12%-152%) for analytes in absolute concentrations. Result normalization by forming ratios to the upper reference limits did not reduce this variation. Sixty-five percent of reported results were within biological variation-based analytical quality specifications. Clinical interpretation of the obtained analytical results was accurate, and most laboratories established the correct diagnosis in all distributions. Based on a case-based EQA scheme, variations were apparent in analytical and diagnostic performance between European specialist porphyria laboratories. Our findings reinforce the use of EQA schemes as an essential tool to assess both analytical and diagnostic processes and thereby to improve patient care in rare diseases.

  19. Endorsing good quality assurance practices in molecular pathology: risks and recommendations for diagnostic laboratories and external quality assessment providers.

    PubMed

    Tembuyser, Lien; Dequeker, Elisabeth M C

    2016-01-01

    Quality assurance is an indispensable element in a molecular diagnostic laboratory. The ultimate goal is to warrant patient safety. Several risks that can compromise high quality procedures are at stake, from sample collection to the test performed by the laboratory, the reporting of test results to clinicians, and the organization of effective external quality assessment schemes. Quality assurance should therefore be safeguarded at each level and should imply a holistic multidisciplinary approach. This review aims to provide an overview of good quality assurance practices and discusses certain risks and recommendations to promote and improve quality assurance for both diagnostic laboratories and for external quality assessment providers. The number of molecular targets is continuously rising, and new technologies are evolving. As this poses challenges for clinical implementation and increases the demand for external quality assessment, the formation of an international association for improving quality assurance in molecular pathology is called for.

  20. Evaluating a mobile application for improving clinical laboratory test ordering and diagnosis.

    PubMed

    Meyer, Ashley N D; Thompson, Pamela J; Khanna, Arushi; Desai, Samir; Mathews, Benji K; Yousef, Elham; Kusnoor, Anita V; Singh, Hardeep

    2018-04-20

    Mobile applications for improving diagnostic decision making often lack clinical evaluation. We evaluated if a mobile application improves generalist physicians' appropriate laboratory test ordering and diagnosis decisions and assessed if physicians perceive it as useful for learning. In an experimental, vignette study, physicians diagnosed 8 patient vignettes with normal prothrombin times (PT) and abnormal partial thromboplastin times (PTT). Physicians made test ordering and diagnosis decisions for 4 vignettes using each resource: a mobile app, PTT Advisor, developed by the Centers for Disease Control and Prevention (CDC)'s Clinical Laboratory Integration into Healthcare Collaborative (CLIHC); and usual clinical decision support. Then, physicians answered questions regarding their perceptions of the app's usefulness for diagnostic decision making and learning using a modified Kirkpatrick Training Evaluation Framework. Data from 368 vignettes solved by 46 physicians at 7 US health care institutions show advantages for using PTT Advisor over usual clinical decision support on test ordering and diagnostic decision accuracy (82.6 vs 70.2% correct; P < .001), confidence in decisions (7.5 vs 6.3 out of 10; P < .001), and vignette completion time (3:02 vs 3:53 min.; P = .06). Physicians reported positive perceptions of the app's potential for improved clinical decision making, and recommended it be used to address broader diagnostic challenges. A mobile app, PTT Advisor, may contribute to better test ordering and diagnosis, serve as a learning tool for diagnostic evaluation of certain clinical disorders, and improve patient outcomes. Similar methods could be useful for evaluating apps aimed at improving testing and diagnosis for other conditions.

  1. Point-of-care diagnostics: extending the laboratory network to reach the last mile.

    PubMed

    Drain, Paul K; Rousseau, Christine

    2017-03-01

    More point-of-care (POC) diagnostic tests are becoming available for HIV diagnosis and treatment in resource-limited settings. These novel technologies have the potential to foster decentralized HIV care and treatment for the benefit of clinical laboratories, HIV clinics, and HIV-infected patients. There continue to be many business, technological, and operational challenges that limit product development and regulatory approval, which limits products available for the required operational and cost-effectiveness studies and delays policy adoption and implementation. Although the rapid HIV diagnostic test has been widely successful, the pathways for POC CD4 cell count and HIV viral load assay analyzers have been more challenging. We describe significant hurdles for product development, approval, and implementation, which include the business case, technical development, clinical impact, and integrating laboratory and clinical networks. The objective of this review is to highlight the obstacles for developing and implementing appropriate strategies for POC HIV testing assays to improve the clinical services for HIV-infected patients in resource-limited settings.

  2. 42 CFR 414.510 - Laboratory date of service for clinical laboratory and pathology specimens.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Laboratory date of service for clinical laboratory and pathology specimens. 414.510 Section 414.510 Public Health CENTERS FOR MEDICARE & MEDICAID... AND OTHER HEALTH SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.510 Laboratory...

  3. Clinical laboratory: bigger is not always better.

    PubMed

    Plebani, Mario

    2018-06-27

    Laboratory services around the world are undergoing substantial consolidation and changes through mechanisms ranging from mergers, acquisitions and outsourcing, primarily based on expectations to improve efficiency, increasing volumes and reducing the cost per test. However, the relationship between volume and costs is not linear and numerous variables influence the end cost per test. In particular, the relationship between volumes and costs does not span the entire platter of clinical laboratories: high costs are associated with low volumes up to a threshold of 1 million test per year. Over this threshold, there is no linear association between volumes and costs, as laboratory organization rather than test volume more significantly affects the final costs. Currently, data on laboratory errors and associated diagnostic errors and risk for patient harm emphasize the need for a paradigmatic shift: from a focus on volumes and efficiency to a patient-centered vision restoring the nature of laboratory services as an integral part of the diagnostic and therapy process. Process and outcome quality indicators are effective tools to measure and improve laboratory services, by stimulating a competition based on intra- and extra-analytical performance specifications, intermediate outcomes and customer satisfaction. Rather than competing with economic value, clinical laboratories should adopt a strategy based on a set of harmonized quality indicators and performance specifications, active laboratory stewardship, and improved patient safety.

  4. Laboratory Diagnosis of Infective Endocarditis

    PubMed Central

    Liesman, Rachael M.; Pritt, Bobbi S.; Maleszewski, Joseph J.

    2017-01-01

    ABSTRACT Infective endocarditis is life-threatening; identification of the underlying etiology informs optimized individual patient management. Changing epidemiology, advances in blood culture techniques, and new diagnostics guide the application of laboratory testing for diagnosis of endocarditis. Blood cultures remain the standard test for microbial diagnosis, with directed serological testing (i.e., Q fever serology, Bartonella serology) in culture-negative cases. Histopathology and molecular diagnostics (e.g., 16S rRNA gene PCR/sequencing, Tropheryma whipplei PCR) may be applied to resected valves to aid in diagnosis. Herein, we summarize recent knowledge in this area and propose a microbiologic and pathological algorithm for endocarditis diagnosis. PMID:28659319

  5. ASVCP quality assurance guidelines: external quality assessment and comparative testing for reference and in-clinic laboratories.

    PubMed

    Camus, Melinda S; Flatland, Bente; Freeman, Kathleen P; Cruz Cardona, Janice A

    2015-12-01

    The purpose of this document is to educate providers of veterinary laboratory diagnostic testing in any setting about comparative testing. These guidelines will define, explain, and illustrate the importance of a multi-faceted laboratory quality management program which includes comparative testing. The guidelines will provide suggestions for implementation of such testing, including which samples should be tested, frequency of testing, and recommendations for result interpretation. Examples and a list of vendors and manufacturers supplying control materials and services to veterinary laboratories are also included. © 2015 American Society for Veterinary Clinical Pathology.

  6. Evaluating laboratory approaches to the identification of lupus anticoagulants: a diagnostic challenge from the RCPA Haematology QAP.

    PubMed

    Bonar, Roslyn; Favaloro, Emmanuel; Zebeljan, Diane; Rosenfeld, David; Kershaw, Geoff; Mohammed, Soma; Marsden, Katherine; Hertzberg, Mark

    2012-04-01

    Laboratory identification of lupus anticoagulants (LA), an important component of the clinical diagnosis of the autoimmune disorder antiphospholipid syndrome (APS), is challenged by the heterogeneity of tests available, the diagnostic and laboratory approach undertaken, and the heterogeneity of the autoantibodies present. : To assess the laboratory approach for investigation of LA, as well as the utility of various tests and test approaches, given a difficult clinical scenario in which LA might or might not be present. Ninety-three participants in the Royal College of Pathologists of Australasia (RCPA) Haematology Quality Assurance Program (QAP) were sent 4  mL of a complex but strongly positive LA sample blinded to the nature of the abnormality. Seventy-three (79%) participants returned results and in most cases diagnostic interpretations. The laboratory approach to LA investigation of this sample was quite varied: 34.7% of participants concluded the sample was LA negative, with 91.7% of these performing dilute Russell viper venom time (dRVVT) testing without mixing, whereas 43.5% of participants identified a strong LA, with 96.7% of these having performed mixing studies. Most laboratories reporting negative LA instead identified the false presence of specific factor inhibitors against a variety of factors, including II, V and VIII. For this difficult challenge, performance of non-mixing dRVVT was associated with a high false negative LA rate. (C) 2012 Royal College of Pathologists of Australasia.

  7. Modeling Complex Workflow in Molecular Diagnostics

    PubMed Central

    Gomah, Mohamed E.; Turley, James P.; Lu, Huimin; Jones, Dan

    2010-01-01

    One of the hurdles to achieving personalized medicine has been implementing the laboratory processes for performing and reporting complex molecular tests. The rapidly changing test rosters and complex analysis platforms in molecular diagnostics have meant that many clinical laboratories still use labor-intensive manual processing and testing without the level of automation seen in high-volume chemistry and hematology testing. We provide here a discussion of design requirements and the results of implementation of a suite of lab management tools that incorporate the many elements required for use of molecular diagnostics in personalized medicine, particularly in cancer. These applications provide the functionality required for sample accessioning and tracking, material generation, and testing that are particular to the evolving needs of individualized molecular diagnostics. On implementation, the applications described here resulted in improvements in the turn-around time for reporting of more complex molecular test sets, and significant changes in the workflow. Therefore, careful mapping of workflow can permit design of software applications that simplify even the complex demands of specialized molecular testing. By incorporating design features for order review, software tools can permit a more personalized approach to sample handling and test selection without compromising efficiency. PMID:20007844

  8. 76 FR 33303 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-08

    ... comments should be received within 60 days of this notice. Proposed Project Survey of Rapid Influenza... Description The Survey of Rapid Influenza Diagnostic Testing Practices in Clinical Laboratories is a national systematic study investigating rapid influenza diagnostic testing practices in clinical [[Page 33304...

  9. Comparison of visual and automated Deki Reader interpretation of malaria rapid diagnostic tests in rural Tanzanian military health facilities.

    PubMed

    Kalinga, Akili K; Mwanziva, Charles; Chiduo, Sarah; Mswanya, Christopher; Ishengoma, Deus I; Francis, Filbert; Temu, Lucky; Mahikwano, Lucas; Mgata, Saidi; Amoo, George; Anova, Lalaine; Wurrapa, Eyako; Zwingerman, Nora; Ferro, Santiago; Bhat, Geeta; Fine, Ian; Vesely, Brian; Waters, Norman; Kreishman-Deitrick, Mara; Hickman, Mark; Paris, Robert; Kamau, Edwin; Ohrt, Colin; Kavishe, Reginald A

    2018-05-29

    Although microscopy is a standard diagnostic tool for malaria and the gold standard, it is infrequently used because of unavailability of laboratory facilities and the absence of skilled readers in poor resource settings. Malaria rapid diagnostic tests (RDT) are currently used instead of or as an adjunct to microscopy. However, at very low parasitaemia (usually < 100 asexual parasites/µl), the test line on malaria rapid diagnostic tests can be faint and consequently hard to visualize and this may potentially affect the interpretation of the test results. Fio Corporation (Canada), developed an automated RDT reader named Deki Reader™ for automatic analysis and interpretation of rapid diagnostic tests. This study aimed to compare visual assessment and automated Deki Reader evaluations to interpret malaria rapid diagnostic tests against microscopy. Unlike in the previous studies where expert laboratory technicians interpreted the test results visually and operated the device, in this study low cadre health care workers who have not attended any formal professional training in laboratory sciences were employed. Finger prick blood from 1293 outpatients with fever was tested for malaria using RDT and Giemsa-stained microscopy for thick and thin blood smears. Blood samples for RDTs were processed according to manufacturers' instructions automated in the Deki Reader. Results of malaria diagnoses were compared between visual and the automated devise reading of RDT and microscopy. The sensitivity of malaria rapid diagnostic test results interpreted by the Deki Reader was 94.1% and that of visual interpretation was 93.9%. The specificity of malaria rapid diagnostic test results was 71.8% and that of human interpretation was 72.0%. The positive predictive value of malaria RDT results by the Deki Reader and visual interpretation was 75.8 and 75.4%, respectively, while the negative predictive values were 92.8 and 92.4%, respectively. The accuracy of RDT as interpreted by DR and visually was 82.6 and 82.1%, respectively. There was no significant difference in performance of RDTs interpreted by either automated DR or visually by unskilled health workers. However, despite the similarities in performance parameters, the device has proven useful because it provides stepwise guidance on processing RDT, data transfer and reporting.

  10. Information engineering for molecular diagnostics.

    PubMed Central

    Sorace, J. M.; Ritondo, M.; Canfield, K.

    1994-01-01

    Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937

  11. Diagnostic Approach to Acute Diarrheal Illness in a Military Population on Training Exercises in Thailand, a Region of Campylobacter Hyperendemicity▿

    PubMed Central

    Tribble, David R.; Baqar, Shahida; Pang, Lorrin W.; Mason, Carl; Houng, Huo-Shu H.; Pitarangsi, Chittima; Lebron, Carlos; Armstrong, Adam; Sethabutr, Orntipa; Sanders, John W.

    2008-01-01

    High rates of Campylobacter fluoroquinolone resistance highlight the need to evaluate diagnostic strategies that can be used to assist with clinical management. Diagnostic tests were evaluated with U.S. soldiers presenting with acute diarrhea during deployment in Thailand. The results of bedside and field laboratory diagnostic tests were compared to stool microbiology findings for 182 enrolled patients. Campylobacter jejuni was isolated from 62% of the cases. Clinical and laboratory findings at the time of presentation were evaluated to determine their impact on the posttest probability, defined as the likelihood of a diagnosis of Campylobacter infection. Clinical findings, the results of tests for inflammation (stool occult blood testing [Hemoccult], fecal leukocytes, fecal lactoferrin, plasma C-reactive protein), and the numbers of Campylobacter-specific antibody-secreting cells in peripheral blood failed to increase the posttest probability above 90% in this setting of Campylobacter hyperendemicity when these findings were present. Positive results by a Campylobacter-specific commercial enzyme immunoassay (EIA) and, less so, a research PCR were strong positive predictors. The negative predictive value for ruling out Campylobacter infection, defined as a posttest probability of less than 10%, was similarly observed with these Campylobacter-specific stool-based tests as well the fecal leukocyte test. Compared to the other tests evaluated, the Campylobacter EIA is a sensitive and specific rapid diagnostic test that may assist with diagnostic evaluation, with consideration of the epidemiological setting, logistics, and cost. PMID:18234869

  12. Perspective for the development of companion diagnostics and regulatory landscape to encourage personalized medicine in Japan.

    PubMed

    Tazawa, Yoshiaki

    2016-01-01

    On July 1st, 2013, the Ministry of Health, Labor and Welfare (MHLW) issued an official notification regarding the co-development of companion diagnostics (CDx) with a drug which requires any exclusive diagnostic test or medical device to predict efficacy or adverse reactions to the drug. The main frame and contents in the MHLW's notification are quite similar to the summaries in the final guidance issued by the US Food and Drug Administration (FDA) on August 6th, 2014 Guidance for Industry and Food and Drug Administration Staff (In Vitro Companion Diagnostic Devices, [2014] ), and these recommend industries to develop, study and submit CDx and the corresponding drug contemporaneously as much as possible. Following the MHLW's notification, the Pharmaceutical and Medical Device Agency (PMDA) notified on December 26th, 2013, "the technical guidance for co-development of CDx and the drug" that mentioned the regulatory requirements for clinical trial of the drug and CDx as well as analytical validity of CDx required for the trials. These official notifications from the Ministry and the Agency may be useful for pharmaceutical and diagnostics makers to understand how they should co-develop and validate CDx for clinical trials and regulatory submission. However, since the most anticipated technologies such as the next generation sequencer (NGS) are more complex and its medical risks could be high level, the existing regulatory system focusing on only diagnostics reagents and devices that are developed and manufactured by in vitro diagnostics (IVD) makers may be no longer suitable for the characteristics of CDx for the future.As an increase of clinical needs for multiple biomarkers assay by DNA sequencer, on November 19th, 2013, the FDA cleared 510 K for NGS and its universal kit. On October 3rd, 2014, moreover, the agency notified two drafts of guidance (Anticipated Details of the Draft Guidance for Industry, Food and Drug Administration Staff, and Clinical Laboratory in Framework for Regulatory Oversight of Laboratory Developed Tests (LDTs), [2014]; Anticipated Details of the Draft Guidance for Industry, Food and Drug Administration Staff, and Clinical Laboratory in FDA Notification and Medical Device Reporting for Laboratory Developed Tests (LDT), [2014]) for oversight of laboratory developed tests (LDTs) with medium or high medical risks. These FDA's strategic decisions and new regulatory frameworks may allow the clinical laboratories to develop and perform more easily NGS-based CDx under the certification of Clinical Laboratory Improvement Amendments (CLIA). However, neither law nor regulated quality management system similar to the CLIA exists in Japan. To effectively validate LDTs and NGS for medical practice, Japan should learn more the current regulatory changes and initiatives in the US, as well as to reform the regulatory frameworks and create any regulated quality management system for clinical laboratory testing to be reimbursed.

  13. Requirements for diagnosis of malaria at different levels of the laboratory network in Africa.

    PubMed

    Long, Earl G

    2009-06-01

    The rapid increase of resistance to cheap, reliable antimalarials, the increasing cost of effective drugs, and the low specificity of clinical diagnosis has increased the need for more reliable diagnostic methods for malaria. The most commonly used and most reliable remains microscopic examination of stained blood smears, but this technique requires skilled personnel, precision instruments, and ideally a source of electricity. Microscopy has the advantage of enabling the examiner to identify the species, stage, and density of an infection. An alternative to microscopy is the rapid diagnostic test (RDT), which uses a labeled monoclonal antibody to detect circulating parasitic antigens. This test is most commonly used to detect Plasmodium falciparum infections and is available in a plastic cassette format. Both microscopy and RDTs should be available at all levels of laboratory service in endemic areas, but in peripheral laboratories with minimally trained staff, the RDT may be a more practical diagnostic method.

  14. [Evaluation of quality of HIV diagnostic procedures in Poland].

    PubMed

    Parczewski, Miłosz; Madaliński, Kazimierz; Leszczyszyn-Pynka, Magdalena; Boroń-Kaczmarska, Anna

    2010-01-01

    The aim of this work was quality assessment of HIV diagnostic procedures in Poland, including human and technical resources as well as laboratory practice. Sixty questionnaires were distributed among diagnostic centers to obtain qualitative data. Basing on the survey data serological control using coded panels of HIV-1/2 samples was performed. Thirty-one filled questionnaires were received (50.8%). Surveyed laboratories perform from 350 to 5500 serological screening tests per year. In most of laboratories fourth generation assays are available, while Blood Donation Centers screen the blood both with serological assays and by HIV-RNA detection. Sanitary and Epidemiological Stations and academic laboratories hold the ISO/IEC 17025 or IS0 9001:2001 accreditation, five of the surveyed centers participate in Labquality assurance and two in Quality Control in Molecular Diagnostics programs. Data of control serological testing were received from 21 centers. In the quality control assessment 194 analyses were performed with 91 true negative, 2 false negative, 96 true positive and 5 false positive results. False negative rate of % and false positive rate of 5.2% was noted for this study. Currently, virtually no guidelines related to the HIV-diagnostics quality assurance and control in Poland are in delineated. Development of the national unified quality control system, basing on the central institution is highly desirable. National certification within the frames of the quality control and assurance program should be mandatory for all the diagnostic labs, and aim at improvement of reliability of the result distributed among clinicians and patients.

  15. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    PubMed

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  16. 77 FR 41188 - Clinical Laboratory Improvement Advisory Committee (CLIAC)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ... technological advances, such as new test methods and the electronic transmission of laboratory information... potential need for educational materials and resources for sites that test under a Provider-performed Microscopy Certificate; and the increased use of culture-independent microbiology diagnostics and the impact...

  17. RPR test

    MedlinePlus

    Rapid plasma reagin test; Syphilis screening test ... Chernecky CC, Berger BJ. Rapid plasma regain (RPR) test – blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier ...

  18. Skull x-ray

    MedlinePlus

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... Chernecky CC, Berger BJ. Radiography of skull, chest, and cervical spine - diagnostic. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. ...

  19. Evidence of clinical utility: an unmet need in molecular diagnostics for patients with cancer.

    PubMed

    Parkinson, David R; McCormack, Robert T; Keating, Susan M; Gutman, Steven I; Hamilton, Stanley R; Mansfield, Elizabeth A; Piper, Margaret A; Deverka, Patricia; Frueh, Felix W; Jessup, J Milburn; McShane, Lisa M; Tunis, Sean R; Sigman, Caroline C; Kelloff, Gary J

    2014-03-15

    This article defines and describes best practices for the academic and business community to generate evidence of clinical utility for cancer molecular diagnostic assays. Beyond analytical and clinical validation, successful demonstration of clinical utility involves developing sufficient evidence to demonstrate that a diagnostic test results in an improvement in patient outcomes. This discussion is complementary to theoretical frameworks described in previously published guidance and literature reports by the U.S. Food and Drug Administration, Centers for Disease Control and Prevention, Institute of Medicine, and Center for Medical Technology Policy, among others. These reports are comprehensive and specifically clarify appropriate clinical use, adoption, and payer reimbursement for assay manufacturers, as well as Clinical Laboratory Improvement Amendments-certified laboratories, including those that develop assays (laboratory developed tests). Practical criteria and steps for establishing clinical utility are crucial to subsequent decisions for reimbursement without which high-performing molecular diagnostics will have limited availability to patients with cancer and fail to translate scientific advances into high-quality and cost-effective cancer care. See all articles in this CCR Focus section, "The Precision Medicine Conundrum: Approaches to Companion Diagnostic Co-development." ©2014 AACR.

  20. Recent advances in tuberculosis diagnostics in resource-limited settings.

    PubMed

    Seki, Mitsuko; Kim, Chang-Ki; Hayakawa, Satoshi; Mitarai, Satoshi

    2018-04-19

    Smear-negative and drug-resistant cases of tuberculosis (TB) disease necessitate the development of new diagnostic methods, especially in resource-limited settings. To improve the current TB situations, sensitive and specific TB point-of-care tests (POCTs) should be developed. This review addresses the current status of TB, novel diagnostic methodologies for TB, and the impact of those new diagnostics on TB control in such situations. Moreover, the perspective of TB management based on laboratory examinations is described. Smear microscopy with sputum samples is the only laboratory examination available in many resource-limited settings and is still used globally. Several nucleic acid amplification tests (NATs) have been developed. The World Health Organization (WHO) endorsed novel diagnostics based on NATs and updated their definition of a bacteriologically confirmed case requiring the biological specimen to be positive by smear microscopy, culture, or the WHO-recommended rapid diagnostic protocols. The use of new diagnostics increased the number of bacteriologically confirmed TB cases. Novel diagnostics are now available, but their sensitivity is still lower than that of conventional liquid culture method. To address the increasing incidence of TB, more resources including novel diagnostics as POCTs with higher sensitivity must be allocated to healthcare systems.

  1. A computational framework for converting textual clinical diagnostic criteria into the quality data model.

    PubMed

    Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian

    2016-10-01

    Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. External quality assessment for arbovirus diagnostics in the World Health Organization Western Pacific Region, 2013–2016: improving laboratory quality over the years

    PubMed Central

    Abdad, Mohammad Yazid; Squires, Raynal C; Cognat, Sebastien; Oxenford, Christopher John

    2017-01-01

    Arboviruses continue to pose serious public health threats in the World Health Organization (WHO) Western Pacific Region. As such, laboratories need to be equipped for their accurate detection. In 2011, to ensure test proficiency, the WHO Regional Office for the Western Pacific piloted an external quality assessment (EQA) programme for arbovirus diagnostics. By 2016, it had grown into a global programme with participation of 96 laboratories worldwide, including 25 laboratories from 19 countries, territories and areas in the Region. The test performance of the 25 laboratories in the Region in 2016 was high with 23 (92%) reporting correct results in all specimens for dengue and chikungunya viruses. For Zika virus, 18 (72%) of the 25 laboratories reported correct results in all specimens, while seven (28%) demonstrated at least one error. When comparing iterations of this EQA programme in the Region between 2013 and 2016, the number of participating laboratories increased from 18 to 25. The first round only included dengue virus, while the latest round additionally included chikungunya, Zika and yellow fever viruses. Proficiency for molecular detection of dengue virus remained high (83–94%) over the four-year period. The observed proficiency for arbovirus diagnostics between 2013 and 2016 is an indicator of laboratory quality improvement in the Region. PMID:29051839

  3. [Laboratory accreditation and proficiency testing].

    PubMed

    Kuwa, Katsuhiko

    2003-05-01

    ISO/TC 212 covering clinical laboratory testing and in vitro diagnostic test systems will issue the international standard for medical laboratory quality and competence requirements, ISO 15189. This standard is based on the ISO/IEC 17025, general requirements for competence of testing and calibration laboratories and ISO 9001, quality management systems-requirements. Clinical laboratory services are essential to patient care and therefore should be available to meet the needs of all patients and clinical personnel responsible for human health care. If a laboratory seeks accreditation, it should select an accreditation body that operates according to this international standard and in a manner which takes into account the particular requirements of clinical laboratories. Proficiency testing should be available to evaluate the calibration laboratories and reference measurement laboratories in clinical medicine. Reference measurement procedures should be of precise and the analytical principle of measurement applied should ensure reliability. We should be prepared to establish a quality management system and proficiency testing in clinical laboratories.

  4. Practical diagnostic testing for human immunodeficiency virus.

    PubMed Central

    Jackson, J B; Balfour, H H

    1988-01-01

    Since the discovery of human immunodeficiency virus (HIV) as the causative agent of acquired immunodeficiency syndrome in 1983, there has been a proliferation of diagnostic tests. These assays can be used to detect the presence of HIV antibody, HIV antigen, HIV ribonucleic and deoxyribonucleic acids, and HIV reverse transcriptase. Enzyme-linked immunosorbent assays, Western blot, radioimmunoprecipitation assays, indirect immunofluorescence assays, reverse transcriptase assays, and several molecular hybridization techniques are currently available. Enzyme-linked immunosorbent, Western blot, and indirect immunofluorescence assays for HIV antibody are very sensitive, specific, and adaptable to most laboratories. An enzyme-linked immunosorbent assay for HIV antigen is also readily adaptable to most laboratories and will be commercially available soon. While the other assays are more tedious, they are valuable confirmatory tests and are suitable for reference laboratories. The biohazards of performing HIV testing can be minimized with proper biosafety measures. Images PMID:3060241

  5. External Quality Assessment for Zika Virus Molecular Diagnostic Testing, Brazil.

    PubMed

    Fischer, Carlo; Pedroso, Celia; Mendrone, Alfredo; Bispo de Filippis, Ana Maria; Vallinoto, Antonio Carlos Rosário; Ribeiro, Bergmann Morais; Durigon, Edison Luiz; Marques, Ernesto T A; Campos, Gubio S; Viana, Isabelle F T; Levi, José Eduardo; Scarpelli, Luciano Cesar; Nogueira, Mauricio Lacerda; Bastos, Michele de Souza; Souza, Nathalia C Santiago; Khouri, Ricardo; Lira, Sanny; Komninakis, Shirley Vasconcelos; Baronti, Cécile; Charrel, Rémi N; Kümmerer, Beate M; Drosten, Christian; Brites, Carlos; de Lamballerie, Xavier; Niedrig, Matthias; Netto, Eduardo Martins; Drexler, Jan Felix

    2018-05-01

    We conducted an external quality assessment of Zika virus molecular diagnostic tests in Brazil using a new Zika virus standard. Of 15 laboratories, 73% showed limited sensitivity and specificity. Viral load estimates varied significantly. Continuous quality assurance is needed to adequately estimate risk for Zika virus-associated disease and determine patient care.

  6. OIE Collaborating Centre for Biorisk Management Strategic Plan.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brass, Van Hildren

    Due to efforts by individual nations and the international community to monitor and control natural occurring outbreaks of animal and zoonotic diseases, any number and variety of select agents and especially dangerous pathogens can be found at diagnostic laboratories around the world. Diagnostic testing is a crucial aspect of disease surveillance, but the organized collection and testing of diagnostic samples from the animal and human population at laboratories has created a repository of disease agents and toxins that could cause serious harm if released or acquired by nefarious means. The delicate balance between public health disease surveillance and the managementmore » of biorisks at facilities utilized in surveillance is a necessary goal of veterinary public health.« less

  7. A review of current and future molecular diagnostic tests for use in the microbiology laboratory.

    PubMed

    Jannes, Geert; De Vos, Daniel

    2006-01-01

    Nucleic acid-based diagnostics gradually are replacing or complementing culture-based, biochemical, and immunological assays in routine microbiology laboratories. Similar to conventional tests, the first-generation deoxyribonucleic acid assays determined only a single analyte. Recent improvements in detection technologies have paved the way for the development of multiparameter assays using macroarrays or micro-arrays, while the introduction of closed-tube real-time polymerase chain reaction systems has resulted in the development of rapid microbial diagnostics with a reduced contamination risk. The use of these new molecular technologies is not restricted to detection and identification of microbial pathogens but also can be used for genotyping, allowing one to determine antibiotic resistance or to perform microbial fingerprinting.

  8. Variation in Results Release and Patient Portal Access to Diagnostic Test Results at an Academic Medical Center

    PubMed Central

    Krasowski, Matthew D.; Grieme, Caleb V.; Cassady, Brian; Dreyer, Nicholas R.; Wanat, Karolyn A.; Hightower, Maia; Nepple, Kenneth G.

    2017-01-01

    Background: Electronic health records (EHRs) are commonplace in industrialized countries. Many hospitals are granting their patients access to their medical information through online patient portals. In this report, we describe a retrospective analysis of patient access to diagnostic test results released through the patient portal (MyChart; Epic, Inc.) at a state academic medical center. Methods: We analyzed 6 months of data for anatomic pathology, clinical laboratory, and radiology test results to evaluate variations in results release (automated vs. manual) and subsequent patient access to the institutional patient portal. During this period, diagnostic test results were released for all patient encounters including inpatient units, outpatient clinics, and the emergency department. Results: Manual results release by providers before automated release time occurred most commonly in the outpatient setting. The highest rates of access of diagnostic test results occurred for outpatients (about 30% overall view rate), females (two times or more compared to males in nearly every age bracket), and 20–45-year-old. Access rates of diagnostic tests in the emergency department or inpatient units were <10% across all populations. Access of diagnostic test results was very low for 12–17-year-old, likely influenced by institutional policies limiting parental proxy access within this pediatric age range. Approximately 20% of outpatient laboratory results were viewed by patients within 8 h of release from the EHR to the patient portal and 10% within 2 h of release. Conclusions: Patient accessing of diagnostic test results were generally higher for females, outpatients, and 20–45-year-old. Approximately, 20% of outpatient results were viewed quickly by patients after release to the EHR. PMID:29226008

  9. Variation in Results Release and Patient Portal Access to Diagnostic Test Results at an Academic Medical Center.

    PubMed

    Krasowski, Matthew D; Grieme, Caleb V; Cassady, Brian; Dreyer, Nicholas R; Wanat, Karolyn A; Hightower, Maia; Nepple, Kenneth G

    2017-01-01

    Electronic health records (EHRs) are commonplace in industrialized countries. Many hospitals are granting their patients access to their medical information through online patient portals. In this report, we describe a retrospective analysis of patient access to diagnostic test results released through the patient portal (MyChart; Epic, Inc.) at a state academic medical center. We analyzed 6 months of data for anatomic pathology, clinical laboratory, and radiology test results to evaluate variations in results release (automated vs. manual) and subsequent patient access to the institutional patient portal. During this period, diagnostic test results were released for all patient encounters including inpatient units, outpatient clinics, and the emergency department. Manual results release by providers before automated release time occurred most commonly in the outpatient setting. The highest rates of access of diagnostic test results occurred for outpatients (about 30% overall view rate), females (two times or more compared to males in nearly every age bracket), and 20-45-year-old. Access rates of diagnostic tests in the emergency department or inpatient units were <10% across all populations. Access of diagnostic test results was very low for 12-17-year-old, likely influenced by institutional policies limiting parental proxy access within this pediatric age range. Approximately 20% of outpatient laboratory results were viewed by patients within 8 h of release from the EHR to the patient portal and 10% within 2 h of release. Patient accessing of diagnostic test results were generally higher for females, outpatients, and 20-45-year-old. Approximately, 20% of outpatient results were viewed quickly by patients after release to the EHR.

  10. Survey of Clinical Laboratory Practices for 2015 Middle East Respiratory Syndrome Coronavirus Outbreak in the Republic of Korea.

    PubMed

    Lee, Mi-Kyung; Kim, Sinyoung; Kim, Mi-Na; Kweon, Oh Joo; Lim, Yong Kwan; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Sung, Heungsup; Yong, Dongeun; Lee, Hyukmin; Choi, Jong-Rak; Kim, Jeong-Ho

    2016-03-01

    It is crucial to understand the current status of clinical laboratory practices for the largest outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) infections in the Republic of Korea to be well prepared for future emerging infectious diseases. We conducted a survey of 49 clinical laboratories in medical institutions and referral medical laboratories. A short questionnaire to survey clinical laboratory practices relating to MERS-CoV diagnostic testing was sent by email to the directors and clinical pathologists in charge of the clinical laboratories performing MERS-CoV testing. The survey focused on testing volume, reporting of results, resources, and laboratory safety. A total of 40 clinical laboratories responded to the survey. A total of 27,009 MERS-CoV real-time reverse transcription PCR (rRT-PCR) tests were performed. Most of the specimens were sputum (73.5%). The median turnaround time (TAT) was 5.29 hr (first and third quartile, 4.11 and 7.48 hr) in 26 medical institutions. The median TAT of more than a half of the laboratories (57.7%) was less than 6 hr. Many laboratories were able to perform tests throughout the whole week. Laboratory biosafety preparedness included class II biosafety cabinets (100%); separated pre-PCR, PCR, and post-PCR rooms (88.6%); negative pressure pretreatment rooms (48.6%); and negative pressure sputum collection rooms (20.0%). Clinical laboratories were able to quickly expand their diagnostic capacity in response to the 2015 MERS-CoV outbreak. Our results show that clinical laboratories play an important role in the maintenance and enhancement of laboratory response in preparation for future emerging infections.

  11. Survey of Clinical Laboratory Practices for 2015 Middle East Respiratory Syndrome Coronavirus Outbreak in the Republic of Korea

    PubMed Central

    Lee, Mi-Kyung; Kim, Sinyoung; Kim, Mi-Na; Kweon, Oh Joo; Lim, Yong Kwan; Ki, Chang-Seok; Kim, Jae-Seok; Seong, Moon-Woo; Sung, Heungsup; Yong, Dongeun; Lee, Hyukmin; Choi, Jong-Rak

    2016-01-01

    Background It is crucial to understand the current status of clinical laboratory practices for the largest outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) infections in the Republic of Korea to be well prepared for future emerging infectious diseases. Methods We conducted a survey of 49 clinical laboratories in medical institutions and referral medical laboratories. A short questionnaire to survey clinical laboratory practices relating to MERS-CoV diagnostic testing was sent by email to the directors and clinical pathologists in charge of the clinical laboratories performing MERS-CoV testing. The survey focused on testing volume, reporting of results, resources, and laboratory safety. Results A total of 40 clinical laboratories responded to the survey. A total of 27,009 MERS-CoV real-time reverse transcription PCR (rRT-PCR) tests were performed. Most of the specimens were sputum (73.5%). The median turnaround time (TAT) was 5.29 hr (first and third quartile, 4.11 and 7.48 hr) in 26 medical institutions. The median TAT of more than a half of the laboratories (57.7%) was less than 6 hr. Many laboratories were able to perform tests throughout the whole week. Laboratory biosafety preparedness included class II biosafety cabinets (100%); separated pre-PCR, PCR, and post-PCR rooms (88.6%); negative pressure pretreatment rooms (48.6%); and negative pressure sputum collection rooms (20.0%). Conclusions Clinical laboratories were able to quickly expand their diagnostic capacity in response to the 2015 MERS-CoV outbreak. Our results show that clinical laboratories play an important role in the maintenance and enhancement of laboratory response in preparation for future emerging infections. PMID:26709263

  12. Willingness to pay for diagnostic technologies: a review of the contingent valuation literature.

    PubMed

    Lin, Pei-Jung; Cangelosi, Michael J; Lee, David W; Neumann, Peter J

    2013-01-01

    To understand how people value information from diagnostic technologies, we reviewed and analyzed published willingness-to-pay (WTP) studies on the topic. We searched PubMed for English-language articles related to WTP for diagnostic laboratory tests published from 1985 through 2011. We characterized methodological differences across studies, examined individual- and technology-level factors associated with WTP, and summarized median WTP values across different diagnostic tests. We identified 66 relevant WTP studies. Half focused on oncology, while others analyzed infectious diseases (n = 11, 16.1%) and obstetric or gynecological conditions (n = 8, 11.7%), among others. Most laboratory tests included in studies were biological samples/genetic testing (n = 44, 61.1%) or imaging tests (n = 23, 31.9%). Approximately one third of the analyses (n = 20, 30.3%) used discrete-choice questions to elicit WTP values. Higher income, education, disease severity, perceived disease risk, family history, and more accurate tests were in general associated with higher WTP values for diagnostic information. Of the 44 studies with median WTP values available, most reported a median WTP value below $100. The median WTP value for colon or colorectal cancer screening ranged from below $100 to over $1000. The contingent valuation literature in diagnostics has grown rapidly, and suggests that many respondents place considerable value on diagnostic information. There exists, however, great variation in studies with respect to the type of technologies and diseases assessed, respondent characteristics, and study methodology. The perceived value of diagnostic technologies is also influenced by the study design and elicitation methods. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  13. International External Quality Assurance for Laboratory Diagnosis of Diphtheria ▿

    PubMed Central

    Neal, S. E.; Efstratiou, A.

    2009-01-01

    The diphtheria surveillance network (DIPNET) encompassing National Diphtheria Reference Centers from 25 European countries is a Dedicated Surveillance Network recognized by the European Commission. A key DIPNET objective is the quality assessment of microbiological procedures for diphtheria across the European Union and beyond. A detailed questionnaire on the level of reference laboratory services and an external quality assessment (EQA) panel comprising six simulated throat specimens were sent to 34 centers. Twenty-three centers are designated National Diphtheria Reference Centers, with the laboratory in the United Kingdom being the only WHO Collaborating Centre. A variety of screening and identification tests were used, including the cysteinase test (20/34 centers), pyrazinamidase test (17/34 centers), and commercial kits (25/34 centers). The classic Elek test for toxigenicity testing is mostly used (28/34 centers), with variations in serum sources and antitoxin concentrations. Many laboratories reported problems obtaining Elek reagents or media. Only six centers produced acceptable results for all six specimens. Overall, 21% of identification and 13% of toxigenicity reports were unacceptable. Many centers could not isolate the target organism, and most found difficulties with the specimens that contained Corynebacterium striatum as a commensal contaminant. Nineteen centers generated either false-positive or negative toxigenic results, which may have caused inappropriate medical management. The discrepancies in this diphtheria diagnostics EQA alarmingly reflect the urgent need to improve laboratory performance in diphtheria diagnostics in Europe, standardize feasible and robust microbiological methods, and build awareness among public health authorities. Therefore, DIPNET recommends that regular workshops and EQA distributions for diphtheria diagnostics should be supported and maintained. PMID:19828749

  14. Neuropathy Tests

    MedlinePlus

    ... Mutation Mycophenolic Acid Mycoplasma Myoglobin Nicotine and Cotinine Non-High Density Lipoprotein Cholesterol Opioid Testing Osmolality Ova ... that make neuropathy worse Detect and evaluate complications Non-laboratory tests The diagnostic workup for neuropathy begins ...

  15. [Laboratory diagnostics of urogenital clamidiosis].

    PubMed

    Churakov, A A; Kulichenko, A N; Kzakova, E S; Serebrianik, N E; Suvorov, A P; Kutyrev, V V; Glybochko, P V

    2005-02-01

    Laboratory diagnostic tools of urogenital clamidiosis--PCR, ELISA (IgG and IgM) and direct immunofluorescence (DIF)--were comparatively analyzed. The positive PCR result was checked by another PCR test with a different primer; 5 false positive responses were registered (specificity 99.6%). As against PCR, the sensitivity of ELISA made 53%, its specificity -75.5%, the diagnostic value of positive result -58%, the diagnostic value of negative result -71.6% and the diagnostics accuracy -66.7%. The respective DIF parameters were as follows: 36%, 90%, 81.5%, 54.2% and 60.9%. A high rate of detection (above 90%) of the conditionally pathogenic microflora associated with Chlamydia trachomatis (above 110 microbe cells/ml) was pointed out. Hardnerelli and ureaplasms were more often found in female smears, staphylococci and enterococci--in male sperm. It is underlined as important to hold complex examinations for Chlamidia (PCR, ELISA and DIC as an additional test) combined with bacteriological quantification of the conditionally pathogenic microflora and determination of its resistance to antibiotics.

  16. Painful Shoulder in Swimmers: A Diagnostic Challenge.

    ERIC Educational Resources Information Center

    McMaster, William C.

    1986-01-01

    This article discusses the incidence, diagnosis, and treatment of painful shoulder in swimmers, including: regional problems that can cause shoulder pain; physical, clinical, and laboratory tests for diagnostic use; and approaches to management of the problem. (Author/CB)

  17. HLA-B27 antigen

    MedlinePlus

    ... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:654-655. Fagoaga ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 49. Inman RD. ...

  18. Status and test report on the LANL-Boeing APLE/HPO flying-wire beam-profile monitor. Status report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilke, M.; Barlow, D.; Fortgang, C.

    1994-07-01

    The High-Power Oscillator (HPO) demonstration of the Average Power Laser Experiment (APLE) is a collaboration by Los Alamos National Laboratory and Boeing to demonstrate a 10 kW average power, 10 {mu}m free electron laser (FEL). As part of the collaboration, Los Alamos National Laboratory (LANL) is responsible for many of the electron beam diagnostics in the linac, transport, and laser sections. Because of the high duty factor and power of the electron beam, special diagnostics are required. This report describes the flying wire diagnostic required to monitor the beam profile during high-power, high-duty operation. The authors describe the diagnostic andmore » prototype tests on the Los Alamos APLE Prototype Experiment (APEX) FEL. They also describe the current status of the flying wires being built for APLE.« less

  19. Diagnostic Testing and Interpretation of Tests for Autoimmunity

    PubMed Central

    Castro, Christine; Gourley, Mark

    2010-01-01

    Laboratory testing is of great value when evaluating a patient with a suspected autoimmune disease. The results can confirm a diagnosis, estimate disease severity, aid in assessing prognosis and are useful to follow disease activity. Components of the laboratory exam include complete blood count with differential, comprehensive metabolic panel, inflammatory markers, autoantibodies, and flow cytometry. This chapter discusses these components and includes a discussion about organ-specific immunologic diseases where immunological laboratory testing is employed. Comprehensive laboratory evaluation of a suspected autoimmune illness in conjunction with a thorough clinical evaluation provides a better understanding of a patient's immunologic disease. PMID:20061009

  20. Porphyrins blood test

    MedlinePlus

    Chernecky CC, Berger BJ. Porphyrins, quantitative - blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. Philadelphia, PA: Elsevier Saunders; 2013:891-892. ...

  1. Laboratory Tests

    MedlinePlus

    ... Medical Devices Radiation-Emitting Products Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Medical Devices Home Medical Devices Products and Medical Procedures In Vitro Diagnostics Tests Used In Clinical Care Tests Used In Clinical Care ...

  2. Human rabies in India: an audit from a rabies diagnostic laboratory.

    PubMed

    Mani, Reeta Subramaniam; Anand, Ashwini Manoor; Madhusudana, Shampur Narayan

    2016-04-01

    Rabies, an acute progressive encephalomyelitis, continues to be a serious public health problem in India and many other countries in Asia and Africa. The low level of commitment to rabies control is partly attributable to challenges in laboratory diagnosis and lack of adequate surveillance to indicate the disease burden. A laboratory audit of human rabies cases was undertaken to disseminate information on the clinical, demographic, prophylactic and most importantly the laboratory diagnostic aspects of rabies. A retrospective analysis of all clinically suspected human rabies cases, whose samples were received at a rabies diagnostic laboratory in South India in the last 3 years, was performed. Clinical and demographic details of patients were obtained. The clinical samples included cerebrospinal fluid (CSF), serum, saliva and nuchal skin biopsy collected antemortem, and brain tissue obtained post-mortem. Various laboratory tests were performed for diagnosis. Clinical samples from 128 patients with suspected rabies, from 11 states in India, were received for diagnostic confirmation. About 94% of the victims reported dog-bites, more than a third of them were children and most of the victims did not receive adequate post-exposure prophylaxis. Antemortem confirmation of rabies by a combination of laboratory diagnostic assays (detection of viral RNA in CSF, skin and saliva, and neutralising antibodies in CSF) could be achieved in 40.6% cases. Increasing awareness about adequate post-exposure prophylaxis, additional rabies diagnostic facilities, and enhanced human and animal rabies surveillance to indicate the true disease burden are essential to control this fatal disease. © 2016 John Wiley & Sons Ltd.

  3. Molecular Methods and Platforms for Infectious Diseases Testing

    PubMed Central

    Emmadi, Rajyasree; Boonyaratanakornkit, Jerry B.; Selvarangan, Rangaraj; Shyamala, Venkatakrishna; Zimmer, Barbara L.; Williams, Laurina; Bryant, Bonita; Schutzbank, Ted; Schoonmaker, Michele M.; Amos Wilson, Jean A.; Hall, Leslie; Pancholi, Preeti; Bernard, Kathryn

    2011-01-01

    The superior sensitivity and specificity associated with the use of molecular assays has greatly improved the field of infectious disease diagnostics by providing clinicians with results that are both accurate and rapidly obtained. Herein, we review molecularly based infectious disease diagnostic tests that are Food and Drug Administration approved or cleared and commercially available in the United States as of December 31, 2010. We describe specific assays and their performance, as stated in the Food and Drug Administration's Summary of Safety and Effectiveness Data or the Office of In Vitro Diagnostic Device Evaluation and Safety's decision summaries, product inserts, or peer-reviewed literature. We summarize indications for testing, limitations, and challenges related to implementation in a clinical laboratory setting for a wide variety of common pathogens. The information presented in this review will be particularly useful for laboratories that plan to implement or expand their molecular offerings in the near term. PMID:21871973

  4. To test or not to test? Laboratory support for the diagnosis of Lyme borreliosis: a position paper of ESGBOR, the ESCMID study group for Lyme borreliosis.

    PubMed

    Dessau, R B; van Dam, A P; Fingerle, V; Gray, J; Hovius, J W; Hunfeld, K-P; Jaulhac, B; Kahl, O; Kristoferitsch, W; Lindgren, P-E; Markowicz, M; Mavin, S; Ornstein, K; Rupprecht, T; Stanek, G; Strle, F

    2018-02-01

    Lyme borreliosis (LB) is a tick-borne infection caused by Borrelia burgdorferi sensu lato. The most frequent clinical manifestations are erythema migrans and Lyme neuroborreliosis. Currently, a large volume of diagnostic testing for LB is reported, whereas the incidence of clinically relevant disease manifestations is low. This indicates overuse of diagnostic testing for LB with implications for patient care and cost-effective health management. The recommendations provided in this review are intended to support both the clinical diagnosis and initiatives for a more rational use of laboratory testing in patients with clinically suspected LB. This is a narrative review combining various aspects of the clinical and laboratory diagnosis with an educational purpose. The literature search was based on existing systematic reviews, national and international guidelines and supplemented with specific citations. The main recommendations according to current European case definitions for LB are as follows. Typical erythema migrans should be diagnosed clinically and does not require laboratory testing. The diagnosis of Lyme neuroborreliosis requires laboratory investigation of the spinal fluid including intrathecal antibody production, and the remaining disease manifestations require testing for serum antibodies to B. burgdorferi. Testing individuals with non-specific subjective symptoms is not recommended, because of a low positive predictive value. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. All rights reserved.

  5. Current approach in the diagnosis and management of posterior uveitis

    PubMed Central

    Sudharshan, S; Ganesh, Sudha K; Biswas, Jyotrimay

    2010-01-01

    Posterior uveitic entities are varied entities that are infective or non-infective in etiology. They can affect the adjacent structures such as the retina, vitreous, optic nerve head and retinal blood vessels. Thorough clinical evaluation gives a clue to the diagnosis while ancillary investigations and laboratory tests assist in confirming the diagnosis. Newer evolving techniques in the investigations and management have increased the diagnostic yield. In case of diagnostic dilemma, intraocular fluid evaluation for polymerase chain testing for the genome and antibody testing against the causative agent provide greater diagnostic ability. PMID:20029144

  6. Prospects for Nonlinear Laser Diagnostics in the Jet Noise Laboratory

    NASA Technical Reports Server (NTRS)

    Herring, Gregory C.; Hart, Roger C.; Fletcher, mark T.; Balla, R. Jeffrey; Henderson, Brenda S.

    2007-01-01

    Two experiments were conducted to test whether optical methods, which rely on laser beam coherence, would be viable for off-body flow measurement in high-density, compressible-flow wind tunnels. These tests measured the effects of large, unsteady density gradients on laser diagnostics like laser-induced thermal acoustics (LITA). The first test was performed in the Low Speed Aeroacoustics Wind Tunnel (LSAWT) of NASA Langley Research Center's Jet Noise Laboratory (JNL). This flow facility consists of a dual-stream jet engine simulator (with electric heat and propane burners) exhausting into a simulated flight stream, reaching Mach numbers up to 0.32. A laser beam transited the LSAWT flow field and was imaged with a high-speed gated camera to measure beam steering and transverse mode distortion. A second, independent test was performed on a smaller laboratory jet (Mach number < 1.2 and mass flow rate < 0.1 kg/sec). In this test, time-averaged LITA velocimetry and thermometry were performed at the jet exit plane, where the effect of unsteady density gradients is observed on the LITA signal. Both experiments show that LITA (and other diagnostics relying on beam overlap or coherence) faces significant hurdles in the high-density, compressible, and turbulent flow environments similar to those of the JNL.

  7. Implementation science: the laboratory as a command centre.

    PubMed

    Boeras, Debrah I; Nkengasong, John N; Peeling, Rosanna W

    2017-03-01

    Recent advances in point-of-care technologies to ensure universal access to affordable quality-assured diagnostics have the potential to transform patient management, surveillance programmes, and control of infectious diseases. Decentralization of testing can put tremendous stresses on fragile health systems if the laboratory is not involved in the planning, introduction, and scale-up strategies. The impact of investments in novel technologies can only be realized if these tests are evaluated, adopted, and scaled up within the healthcare system with appropriate planning and understanding of the local contexts in which these technologies will be used. In this digital age, the laboratory needs to take on the role of the Command Centre for technology introduction and implementation. Implementation science is needed to understand the political, cultural, economic, and behavioural context for technology introduction. The new paradigm should include: building a comprehensive system of laboratories and point-of-care testing sites to provide quality-assured diagnostic services with good laboratory-clinic interface to build trust in test results and linkage to care; building and coordinating a comprehensive national surveillance and communication system for disease control and global health emergencies; conducting research to monitor the impact of new tools and interventions on improving patient care.

  8. Accuracy of dengue clinical diagnosis with and without NS1 antigen rapid test: Comparison between human and Bayesian network model decision.

    PubMed

    Sa-Ngamuang, Chaitawat; Haddawy, Peter; Luvira, Viravarn; Piyaphanee, Watcharapong; Iamsirithaworn, Sopon; Lawpoolsri, Saranath

    2018-06-18

    Differentiating dengue patients from other acute febrile illness patients is a great challenge among physicians. Several dengue diagnosis methods are recommended by WHO. The application of specific laboratory tests is still limited due to high cost, lack of equipment, and uncertain validity. Therefore, clinical diagnosis remains a common practice especially in resource limited settings. Bayesian networks have been shown to be a useful tool for diagnostic decision support. This study aimed to construct Bayesian network models using basic demographic, clinical, and laboratory profiles of acute febrile illness patients to diagnose dengue. Data of 397 acute undifferentiated febrile illness patients who visited the fever clinic of the Bangkok Hospital for Tropical Diseases, Thailand, were used for model construction and validation. The two best final models were selected: one with and one without NS1 rapid test result. The diagnostic accuracy of the models was compared with that of physicians on the same set of patients. The Bayesian network models provided good diagnostic accuracy of dengue infection, with ROC AUC of 0.80 and 0.75 for models with and without NS1 rapid test result, respectively. The models had approximately 80% specificity and 70% sensitivity, similar to the diagnostic accuracy of the hospital's fellows in infectious disease. Including information on NS1 rapid test improved the specificity, but reduced the sensitivity, both in model and physician diagnoses. The Bayesian network model developed in this study could be useful to assist physicians in diagnosing dengue, particularly in regions where experienced physicians and laboratory confirmation tests are limited.

  9. Evaluation of an external quality assessment program for HIV testing in Haiti, 2006-2011.

    PubMed

    Louis, Frantz Jean; Anselme, Renette; Ndongmo, Clement; Buteau, Josiane; Boncy, Jacques; Dahourou, Georges; Vertefeuille, John; Marston, Barbara; Balajee, S Arunmozhi

    2013-12-01

    To evaluate an external quality assessment (EQA) program for human immunodeficiency virus (HIV) rapid diagnostics testing by the Haitian National Public Health Laboratory (French acronym: LNSP). Acceptable performance was defined as any proficiency testing (PT) score more than 80%. The PT database was reviewed and analyzed to assess the testing performance of the participating laboratories and the impact of the program over time. A total of 242 laboratories participated in the EQA program from 2006 through 2011; participation increased from 70 laboratories in 2006 to 159 in 2011. In 2006, 49 (70%) laboratories had a PT score of 80% or above; by 2011, 145 (97.5%) laboratories were proficient (P < .05). The EQA program for HIV testing ensures quality of testing and allowed the LNSP to document improvements in the quality of HIV rapid testing over time.

  10. Serotonin blood test

    MedlinePlus

    5-HT level; 5-hydroxytryptamine level; Serotonin test ... Chernecky CC, Berger BJ. Serotonin (5-hydroxytryptamine) - serum or blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier ...

  11. Improving diagnostic capability for HPV disease internationally within the NIH-NIAID-Division of AIDS Clinical Trial Networks

    PubMed Central

    Godfrey, Catherine C.; Michelow, Pamela M.; Godard, Mandana; Sahasrabuddhe, Vikrant V.; Darden, Janice; Firnhaber, Cynthia S.; Wetherall, Neal T.; Bremer, James; Coombs, Robert W.; Wilkin, Timothy

    2014-01-01

    Objectives To evaluate an external quality assurance (EQA) program for the laboratory diagnosis of human papillomavirus (HPV) disease that was established to improve international research capability within the Division of AIDS at the National Institute of Allergy and Infectious Disease–supported Adult AIDS Clinical Trials Group network. Methods A three-component EQA scheme was devised comprising assessments of diagnostic accuracy of cytotechnologists and pathologists using available EQA packages, review of quality and accuracy of clinical slides from local sites by an outside expert, and HPV DNA detection using the commercially available HPV test kit. Results Seven laboratories and 17 pathologists in Africa, India, and South America participated. EQA scores were suboptimal for standard packages in three of seven laboratories. There was good agreement between the local laboratory and the central reader 70% of the time (90% confidence interval, 42%-98%). Performance on the College of American Pathologists’ HPV DNA testing panel was successful in all laboratories tested. Conclusions The prequalifying EQA round identified correctable issues that will improve the laboratory diagnosis of HPV related cervical disease at the international sites and will provide a mechanism for ongoing education and continuous quality improvement. PMID:24225757

  12. Diagnostic microbiology in veterinary dermatology: present and future.

    PubMed

    Guardabassi, Luca; Damborg, Peter; Stamm, Ivonne; Kopp, Peter A; Broens, Els M; Toutain, Pierre-Louis

    2017-02-01

    The microbiology laboratory can be perceived as a service provider rather than an integral part of the healthcare team. The aim of this review is to discuss the current challenges of providing a state-of-the-art diagnostic veterinary microbiology service including the identification (ID) and antimicrobial susceptibility testing (AST) of key pathogens in veterinary dermatology. The Study Group for Veterinary Microbiology (ESGVM) of the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) identified scientific, technological, educational and regulatory issues impacting the predictive value of AST and the quality of the service offered by microbiology laboratories. The advent of mass spectrometry has significantly reduced the time required for ID of key pathogens such as Staphylococcus pseudintermedius. However, the turnaround time for validated AST methods has remained unchanged for many years. Beyond scientific and technological constraints, AST methods are not harmonized and clinical breakpoints for some antimicrobial drugs are either missing or inadequate. Small laboratories, including in-clinic laboratories, are usually not adequately equipped to run up-to-date clinical microbiologic diagnostic tests. ESGVM recommends the use of laboratories employing mass spectrometry for ID and broth micro-dilution for AST, and offering assistance by expert microbiologists on pre- and post-analytical issues. Setting general standards for veterinary clinical microbiology, promoting antimicrobial stewardship, and the development of new, validated and rapid diagnostic methods, especially for AST, are among the missions of ESGVM. © 2017 The Authors. Veterinary Dermatology published by John Wiley & Sons Ltd on behalf of the ESVD and ACVD.

  13. Quality Control of Direct Molecular Diagnostics for Methicillin-Resistant Staphylococcus aureus▿

    PubMed Central

    van Belkum, Alex; Niesters, Hubert G. M.; MacKay, William G.; van Leeuwen, Willem B.

    2007-01-01

    Ten samples containing various amounts of methicillin-resistant Staphylococcus aureus (MRSA), methicillin-susceptible S. aureus, methicillin-resistant Staphylococcus epidermidis (MRSE), and combinations thereof were distributed to 51 laboratories for molecular diagnostics testing. Samples containing 102 to 103 MRSA cells were frequently reported to be negative. MRSE samples were scored as negative by all commercial tests but by only two out of three in-house tests. PMID:17581936

  14. Lyssaviruses: special emphasis on rabies virus and other members of the lyssavirus genus.

    PubMed

    Harkess, Graeme; Fooks, Anthony R

    2011-01-01

    Rabies is routinely diagnosed based on the clinical description and history of exposure in a rabies-endemic country. A negative diagnostic test for rabies virus or a related lyssavirus does not exclude the clinical diagnosis. Diagnostic tests are never optimal and are entirely dependent on the nature and quality of the sample supplied. Often, only a sample from a single time point is investigated reducing the overall sensitivity of any diagnosis. With the advent of molecular biology, tests have been developed that are rapid, robust, and sensitive in support of the rapid detection and strain identification of rabies virus from clinical specimens. These molecular tests complement conventional tests in rabies diagnosis, particularly for human cases, for which an early laboratory diagnosis is critical and may decrease the number of unnecessary contacts with the patient, reduce the requirement for invasive and costly interventions, and enable the appropriate medical treatment regimen to be administered for the patient. The barrier to success is in transferring the technology for the latest techniques in rabies diagnosis to rabies-endemic countries. These barriers are not insurmountable and in liaison with international organisations, especially OIE, FAO, and WHO, these diagnostic tests will be validated for rabies diagnosis and surveillance, and implemented in modern and well-equipped diagnostic laboratories throughout the world.

  15. External quality assurance of HER2 fluorescence in situ hybridisation testing: results of a UK NEQAS pilot scheme.

    PubMed

    Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith

    2007-07-01

    Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over-express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the "real world".

  16. Ceruloplasmin blood test

    MedlinePlus

    CP - serum ... Chernecky CC, Berger BJ. Ceruloplasmin (CP) - serum. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier; 2013:321. McPherson ...

  17. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    PubMed

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  18. Development of a miRNA-based diagnostic assay for pancreatic ductal adenocarcinoma.

    PubMed

    Szafranska-Schwarzbach, Anna E; Adai, Alex T; Lee, Linda S; Conwell, Darwin L; Andruss, Bernard F

    2011-04-01

    Diagnosis of pancreatic cancer remains a clinical challenge. Both chronic pancreatitis and pancreatic cancer may present with similar symptoms and similar imaging features, often leading to incorrect interpretation. Thus, the use of an objective molecular test that can discriminate between chronic pancreatitis and pancreatic cancer will be a valuable asset in obtaining a definitive diagnosis of pancreatic cancer. Following Clinical Laboratory Improvement Amendments and College of American Pathologists guidelines, Asuragen Clinical Services Laboratory has developed and validated a laboratory-developed test, miRInform(®) Pancreas, to aid in the identification of pancreatic ductal adenocarcinoma. This molecular diagnostic tool uses reverse-transcription quantitative PCR to measure the expression difference between two miRNAs, miR-196a and miR-217, in fixed tissue specimens. This article describes the test validation process as well as determination of performance parameters of miRInform Pancreas.

  19. Diagnosis of Dengue Infection Using Conventional and Biosensor Based Techniques

    PubMed Central

    Parkash, Om; Hanim Shueb, Rafidah

    2015-01-01

    Dengue is an arthropod-borne viral disease caused by four antigenically different serotypes of dengue virus. This disease is considered as a major public health concern around the world. Currently, there is no licensed vaccine or antiviral drug available for the prevention and treatment of dengue disease. Moreover, clinical features of dengue are indistinguishable from other infectious diseases such as malaria, chikungunya, rickettsia and leptospira. Therefore, prompt and accurate laboratory diagnostic test is urgently required for disease confirmation and patient triage. The traditional diagnostic techniques for the dengue virus are viral detection in cell culture, serological testing, and RNA amplification using reverse transcriptase PCR. This paper discusses the conventional laboratory methods used for the diagnosis of dengue during the acute and convalescent phase and highlights the advantages and limitations of these routine laboratory tests. Subsequently, the biosensor based assays developed using various transducers for the detection of dengue are also reviewed. PMID:26492265

  20. South African Ebola diagnostic response in Sierra Leone: A modular high biosafety field laboratory

    PubMed Central

    Jansen van Vuren, Petrus; Meier, Gunther H.; le Roux, Chantel; Conteh, Ousman S.; Kemp, Alan; Fourie, Cardia; Naidoo, Prabha; Naicker, Serisha; Ohaebosim, Phumza; Storm, Nadia; Hellferscee, Orienka; Ming Sun, Lisa K.; Mogodi, Busisiwe; Prabdial-Sing, Nishi; du Plessis, Desiree; Greyling, Deidre; Loubser, Shayne; Goosen, Mark; McCulloch, Stewart D.; Scott, Terence P.; Moerdyk, Alexandra; Dlamini, Wesley; Konneh, Kelfala; Kamara, Idrissa L.; Sowa, Dauda; Sorie, Samuel; Kargbo, Brima; Madhi, Shabir A.

    2017-01-01

    Background In August 2014, the National Institute for Communicable Diseases (NICD) in South Africa established a modular high-biosafety field Ebola diagnostic laboratory (SA FEDL) near Freetown, Sierra Leone in response to the rapidly increasing number of Ebola virus disease (EVD) cases. Methods and findings The SA FEDL operated in the Western Area of Sierra Leone, which remained a “hotspot” of the EVD epidemic for months. The FEDL was the only diagnostic capacity available to respond to the overwhelming demand for rapid EVD laboratory diagnosis for several weeks in the initial stages of the EVD crisis in the capital of Sierra Leone. Furthermore, the NICD set out to establish local capacity amongst Sierra Leonean nationals in all aspects of the FEDL functions from the outset. This led to the successful hand-over of the FEDL to the Sierra Leone Ministry of Health and Sanitation in March 2015. Between 25 August 2014 and 22 June 2016, the laboratory tested 11,250 specimens mostly from the Western Urban and Western Rural regions of Sierra Leone, of which 2,379 (21.14%) tested positive for Ebola virus RNA. Conclusions The bio-safety standards and the portability of the SA FEDL, offered a cost-effective and practical alternative for the rapid deployment of a field-operated high biocontainment facility. The SA FEDL teams demonstrated that it is highly beneficial to train the national staff in the course of formidable disease outbreak and accomplished their full integration into all operational and diagnostic aspects of the laboratory. This initiative contributed to the international efforts in bringing the EVD outbreak under control in Sierra Leone, as well as capacitating local African scientists and technologists to respond to diagnostic needs that might be required in future outbreaks of highly contagious pathogens. PMID:28628619

  1. South African Ebola diagnostic response in Sierra Leone: A modular high biosafety field laboratory.

    PubMed

    Paweska, Janusz T; Jansen van Vuren, Petrus; Meier, Gunther H; le Roux, Chantel; Conteh, Ousman S; Kemp, Alan; Fourie, Cardia; Naidoo, Prabha; Naicker, Serisha; Ohaebosim, Phumza; Storm, Nadia; Hellferscee, Orienka; Ming Sun, Lisa K; Mogodi, Busisiwe; Prabdial-Sing, Nishi; du Plessis, Desiree; Greyling, Deidre; Loubser, Shayne; Goosen, Mark; McCulloch, Stewart D; Scott, Terence P; Moerdyk, Alexandra; Dlamini, Wesley; Konneh, Kelfala; Kamara, Idrissa L; Sowa, Dauda; Sorie, Samuel; Kargbo, Brima; Madhi, Shabir A

    2017-06-01

    In August 2014, the National Institute for Communicable Diseases (NICD) in South Africa established a modular high-biosafety field Ebola diagnostic laboratory (SA FEDL) near Freetown, Sierra Leone in response to the rapidly increasing number of Ebola virus disease (EVD) cases. The SA FEDL operated in the Western Area of Sierra Leone, which remained a "hotspot" of the EVD epidemic for months. The FEDL was the only diagnostic capacity available to respond to the overwhelming demand for rapid EVD laboratory diagnosis for several weeks in the initial stages of the EVD crisis in the capital of Sierra Leone. Furthermore, the NICD set out to establish local capacity amongst Sierra Leonean nationals in all aspects of the FEDL functions from the outset. This led to the successful hand-over of the FEDL to the Sierra Leone Ministry of Health and Sanitation in March 2015. Between 25 August 2014 and 22 June 2016, the laboratory tested 11,250 specimens mostly from the Western Urban and Western Rural regions of Sierra Leone, of which 2,379 (21.14%) tested positive for Ebola virus RNA. The bio-safety standards and the portability of the SA FEDL, offered a cost-effective and practical alternative for the rapid deployment of a field-operated high biocontainment facility. The SA FEDL teams demonstrated that it is highly beneficial to train the national staff in the course of formidable disease outbreak and accomplished their full integration into all operational and diagnostic aspects of the laboratory. This initiative contributed to the international efforts in bringing the EVD outbreak under control in Sierra Leone, as well as capacitating local African scientists and technologists to respond to diagnostic needs that might be required in future outbreaks of highly contagious pathogens.

  2. The Use of a Mobile Laboratory Unit in Support of Patient Management and Epidemiological Surveillance during the 2005 Marburg Outbreak in Angola

    PubMed Central

    Grolla, Allen; Jones, Steven M.; Fernando, Lisa; Strong, James E.; Ströher, Ute; Möller, Peggy; Paweska, Janusz T.; Burt, Felicity; Pablo Palma, Pedro; Sprecher, Armand; Formenty, Pierre; Roth, Cathy; Feldmann, Heinz

    2011-01-01

    Background Marburg virus (MARV), a zoonotic pathogen causing severe hemorrhagic fever in man, has emerged in Angola resulting in the largest outbreak of Marburg hemorrhagic fever (MHF) with the highest case fatality rate to date. Methodology/Principal Findings A mobile laboratory unit (MLU) was deployed as part of the World Health Organization outbreak response. Utilizing quantitative real-time PCR assays, this laboratory provided specific MARV diagnostics in Uige, the epicentre of the outbreak. The MLU operated over a period of 88 days and tested 620 specimens from 388 individuals. Specimens included mainly oral swabs and EDTA blood. Following establishing on site, the MLU operation allowed a diagnostic response in <4 hours from sample receiving. Most cases were found among females in the child-bearing age and in children less than five years of age. The outbreak had a high number of paediatric cases and breastfeeding may have been a factor in MARV transmission as indicated by the epidemiology and MARV positive breast milk specimens. Oral swabs were a useful alternative specimen source to whole blood/serum allowing testing of patients in circumstances of resistance to invasive procedures but limited diagnostic testing to molecular approaches. There was a high concordance in test results between the MLU and the reference laboratory in Luanda operated by the US Centers for Disease Control and Prevention. Conclusions/Significance The MLU was an important outbreak response asset providing support in patient management and epidemiological surveillance. Field laboratory capacity should be expanded and made an essential part of any future outbreak investigation. PMID:21629730

  3. Advances in in vitro diagnostics in allergy, asthma, and immunology in 2012.

    PubMed

    Renz, Harald

    2013-12-01

    Laboratory tests play an increasing role in risk assessment, diagnostics, and disease monitoring. Great advances have been achieved lately, particularly in the field of clinical immunology and allergy. These include neonatal screening of immunodeficiencies and asthma biomarkers and investigation into the role of recombinant allergens in in vitro testing. The latter area has implications for the diagnostics of food allergy, pollen-induced allergies, asthma, and insect allergies. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  4. Leucine aminopeptidase blood test

    MedlinePlus

    Serum leucine aminopeptidase; LAP - serum ... Chernecky CC, Berger BJ. Leucine aminopeptidase (LAP) - blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier ...

  5. Maintaining Life-saving Testing for Patients With Infectious Diseases: Infectious Diseases Society of America, American Society for Microbiology, and Pan American Society for Clinical Virology Recommendations on the Regulation of Laboratory-developed Tests.

    PubMed

    Caliendo, Angela M; Couturier, Marc R; Ginocchio, Christine C; Hanson, Kimberly E; Miller, Melissa B; Walker, Kimberly E; Frank, Gregory M

    2016-07-15

    In 2014, the US Food and Drug Administration (FDA) proposed to regulate laboratory-developed tests (LDTs)-diagnostics designed, manufactured, and used within a single laboratory. The Infectious Diseases Society of America, the American Society for Microbiology, and the Pan American Society for Clinical Virology recognize that the FDA is committed to protecting patients. However, our societies are concerned that the proposed regulations will limit access to testing and negatively impact infectious diseases (ID) LDTs. In this joint commentary, our societies discuss why LDTs are critical for ID patient care, hospital infection control, and public health responses. We also highlight how the FDA's proposed regulation of LDTs could impair patient access to life-saving tests and stifle innovation in ID diagnostics. Finally, our societies make specific recommendations for the FDA's consideration to reduce the burden of the proposed new rules on clinical laboratories and protect patients' access to state-of-the art, quality LDTs. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  6. The role of the independent clinical laboratory in new assay development and commercialization.

    PubMed

    Ellis, David G

    2003-01-01

    Most would agree that these are exciting times in the field of laboratory medicine. As the body of scientific knowledge expands and research activities, such as those catalyzed by the sequencing of the human genome, bring us closer to the promise of personalized medicine, the clinical laboratory industry will have increasing opportunities to partner with owners of intellectual property to develop and commercialize new diagnostic tests. The large, independent clinical laboratories are particularly well positioned to commercialize important new tests, with their broad market penetration, infrastructure, and the scale to run esoteric tests cost-effectively.

  7. False positive malaria rapid diagnostic test in returning traveler with typhoid fever.

    PubMed

    Meatherall, Bonnie; Preston, Keith; Pillai, Dylan R

    2014-07-09

    Rapid diagnostic tests play a pivotal role in the early diagnosis of malaria where microscopy or polymerase chain reaction are not immediately available. We report the case of a 39 year old traveler to Canada who presented with fever, headache, and abdominal pain after visiting friends and relatives in India. While in India, the individual was not ill and had no signs or symptoms of malaria. Laboratory testing upon his return to Canada identified a false positive malaria rapid diagnostic (BinaxNOW® malaria) result for P. falciparum with coincident Salmonella Typhi bacteraemia without rheumatoid or autoimmune factors. Rapid diagnostic test false positivity for malaria coincided with the presence or absence of Salmonella Typhi in the blood. Clinicians should be aware that Salmonella Typhi infection may result in a false positive malaria rapid diagnostic test. The mechanism of this cross-reactivity is not clear.

  8. An alternative perspective on how laboratory medicine can contribute to solve the health care crisis: a model to save costs by acquiring excellence in diagnostic systems.

    PubMed

    Mussap, Michele

    2014-01-01

    The rapid escalation in health care costs has led to the idea to deliver better care at lower costs, reshaping the responsibilities of the health care system to achieve the goal of creating value for the patient. The pressure for fiscal containment and the progressive reduction in available health care resources originated very short term strategies consisting of abrupt reductions in expenditure, specifically in the provision of clinical pathology laboratory medicine services. However, the impact of laboratory test results on diagnostic and therapeutic interventions has increased enormously in the past decade, due to advances in personalized medicine and to the strictly correlated requirement to use new biomarkers with increasing sensitivity and specificity in clinical practice. In order to create savings by delivering better care there is the need to invest financial resources in purchasing high technology and new sophisticated tests and to promote the expertise of clinical pathologists and laboratory medicine professionals. This approach to creating value in patient health care is more productive and sustainable ethically, morally and economically as a long-term strategy. It can be successfully achieved by applying defined rules that make public-private cooperation clearer, skipping incompatible solutions such as transforming clinical laboratories to 'industrially productive premises', outsourcing laboratory medicine services and using central acquisition of diagnostic systems. © 2013.

  9. Laboratory Diagnosis of Tuberculosis in Resource-Poor Countries: Challenges and Opportunities

    PubMed Central

    Parsons, Linda M.; Somoskövi, Ákos; Gutierrez, Cristina; Lee, Evan; Paramasivan, C. N.; Abimiku, Alash'le; Spector, Steven; Roscigno, Giorgio; Nkengasong, John

    2011-01-01

    Summary: With an estimated 9.4 million new cases globally, tuberculosis (TB) continues to be a major public health concern. Eighty percent of all cases worldwide occur in 22 high-burden, mainly resource-poor settings. This devastating impact of tuberculosis on vulnerable populations is also driven by its deadly synergy with HIV. Therefore, building capacity and enhancing universal access to rapid and accurate laboratory diagnostics are necessary to control TB and HIV-TB coinfections in resource-limited countries. The present review describes several new and established methods as well as the issues and challenges associated with implementing quality tuberculosis laboratory services in such countries. Recently, the WHO has endorsed some of these novel methods, and they have been made available at discounted prices for procurement by the public health sector of high-burden countries. In addition, international and national laboratory partners and donors are currently evaluating other new diagnostics that will allow further and more rapid testing in point-of-care settings. While some techniques are simple, others have complex requirements, and therefore, it is important to carefully determine how to link these new tests and incorporate them within a country's national diagnostic algorithm. Finally, the successful implementation of these methods is dependent on key partnerships in the international laboratory community and ensuring that adequate quality assurance programs are inherent in each country's laboratory network. PMID:21482728

  10. An overview of serological tests currently available for laboratory diagnosis of parasitic infections.

    PubMed

    Fox, J C; Jordan, H E; Kocan, K M; George, T J; Mullins, S T; Barnett, C E; Glenn, B L; Cowell, R L

    1986-03-01

    Current methods and commercial test systems for the diagnosis of parasitic infections in both animals and humans are reviewed. Lists of test kits and their manufacturers are provided along with ordering information: the only commercially available test kits are for the diagnosis of toxoplasmosis in humans or animals and dirofilariasis (heartworm) in dogs. A partial list of diagnostic laboratories and the parasite tests they perform is also provided. Complete lists of diagnostic tests that could be obtained in the private sector are not available but would be useful. Two microfluorometric solid-phase assay systems are reviewed, and adaptations to custom assays for several kinds of parasites are briefly described. User problems in performing tests and interpreting results are stressed with emphasis placed on diagnosis of dirofilariasis in dogs. False-positive serology in dogs without heartworms and negative antibody responses in micro-filariae-positive animals are discussed with respect to proper interpretation of results.

  11. 42 CFR 493.833 - Condition: Diagnostic immunology.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Diagnostic immunology. 493.833 Section 493.833 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...

  12. 42 CFR 493.833 - Condition: Diagnostic immunology.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Diagnostic immunology. 493.833 Section 493.833 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...

  13. An audit of the laboratory diagnosis of cryptosporidiosis in England and Wales.

    PubMed

    Chalmers, Rachel M; Atchison, Christina; Barlow, Katrina; Young, Yvonne; Roche, Anita; Manuel, Rohini

    2015-07-01

    To assess the level of practice consistent with UK national standards for Cryptosporidium testing, an audit was performed of 156 publicly funded clinical microbiology laboratories in England and Wales between August 2013 and April 2014. Responses were received from 85 (54 %) laboratories. First line diagnostic methods used were mainly microscopy with modified Ziehl-Neelsen (mZN) or auramine phenol (AP) staining (68/85, 80 %), enzyme immunoassays (EIAs) (16/85, 19 %) or in-house PCR (1/85, 1 %). The use of EIAs was more widespread than reported previously. Various methods were used for confirmation of positive EIA reactions and laboratories frequently resorted to sending samples to the national reference laboratory for this purpose, indicating that guidance is required for performance monitoring and confirmation of positive reactions. Laboratory positivity rates were related to the diagnostic test used, with highest median rates reported by those using PCR, EIAs or AP microscopy, and the lowest by those using mZN microscopy. One-third of responding laboratories (28/85, 33 %) routinely tested all stools for Cryptosporidium. However, 16 (19 %) laboratories used stool consistency to decide whether to test for this parasite. Other selection criteria included patient age (n = 18; 21 % laboratories), history or clinical details (n = 40; 47 %), duration of hospitalization (n = 18; 21 %) or clinician requests (n = 25; 29 %). To encourage laboratories to test all stools submitted for the investigation of diarrhoeal illness for Cryptosporidium, revision of the guidance in the national standards is under way. This will enable improved assessment of the burden of illness and ability to monitor outbreaks, and measure changes in reported cases.

  14. Point-of-care diagnostics: an advancing sector with nontechnical issues.

    PubMed

    Huckle, David

    2008-11-01

    The particular reasons for the relative lack in development of point-of-care (PoC) diagnostics in a business context were discussed in our sister journal, Expert Review of Medical Devices, over 2 years ago. At that time, it could be seen that the concept of PoC testing was being revisited for at least the fifth time in the last 20 years. There had been important advances in technology but, with changes in global healthcare structures and funding, the overall in vitro diagnostics sector has had sluggish growth. Only molecular diagnostics and PoC testing are growing strongly. PoC testing is now a quarter of the total global in vitro diagnostics market, but largely due to use in diabetes monitoring. An increased focus on areas other than glucose self-testing has created a disturbance in the market. An implementation issue from this disturbance is that of control between central laboratories and the proposed sites for PoC testing. Evidence is presented to show that the first step is likely to be increased use in clinics and outpatient facilities closely linked with the laboratory. The aim will be to control the quality of the test, maintenance of equipment and provide support for the clinician in interpretation. The major problem for effective PoC implementation will be the significant changes to patient pathways that are required. The changes will benefit the patient and clinical outcomes but will require healthcare professionals to change their work patterns. This will be an uphill task!

  15. Background review for diagnostic test development for Zika virus infection.

    PubMed

    Charrel, Rémi N; Leparc-Goffart, Isabelle; Pas, Suzan; de Lamballerie, Xavier; Koopmans, Marion; Reusken, Chantal

    2016-08-01

    To review the state of knowledge about diagnostic testing for Zika virus infection and identify areas of research needed to address the current gaps in knowledge. We made a non-systematic review of the published literature about Zika virus and supplemented this with information from commercial diagnostic test kits and personal communications with researchers in European preparedness networks. The review covered current knowledge about the geographical spread, pathogen characteristics, life cycle and infection kinetics of the virus. The available molecular and serological tests and biosafety issues are described and discussed in the context of the current outbreak strain. We identified the following areas of research to address current knowledge gaps: (i) an urgent assessment of the laboratory capacity and capability of countries to detect Zika virus; (ii) rapid and extensive field validation of the available molecular and serological tests in areas with and without Zika virus transmission, with a focus on pregnant women; (iii) monitoring the genomic diversity of circulating Zika virus strains; (iv) prospective studies into the virus infection kinetics, focusing on diagnostic sampling (specimen types, combinations and timings); and (v) developing external quality assessments for molecular and serological testing, including differential diagnosis for similar viruses and symptom clusters. The availability of reagents for diagnostic development (virus strains and antigens, quantified viral ribonucleic acid) needs to be facilitated. An international laboratory response is needed, including preparation of protocols for prospective studies to address the most pressing information needs.

  16. Background review for diagnostic test development for Zika virus infection

    PubMed Central

    Charrel, Rémi N; Leparc-Goffart, Isabelle; Pas, Suzan; de Lamballerie, Xavier; Koopmans, Marion; Reusken, Chantal

    2016-01-01

    Abstract Objective To review the state of knowledge about diagnostic testing for Zika virus infection and identify areas of research needed to address the current gaps in knowledge. Methods We made a non-systematic review of the published literature about Zika virus and supplemented this with information from commercial diagnostic test kits and personal communications with researchers in European preparedness networks. The review covered current knowledge about the geographical spread, pathogen characteristics, life cycle and infection kinetics of the virus. The available molecular and serological tests and biosafety issues are described and discussed in the context of the current outbreak strain. Findings We identified the following areas of research to address current knowledge gaps: (i) an urgent assessment of the laboratory capacity and capability of countries to detect Zika virus; (ii) rapid and extensive field validation of the available molecular and serological tests in areas with and without Zika virus transmission, with a focus on pregnant women; (iii) monitoring the genomic diversity of circulating Zika virus strains; (iv) prospective studies into the virus infection kinetics, focusing on diagnostic sampling (specimen types, combinations and timings); and (v) developing external quality assessments for molecular and serological testing, including differential diagnosis for similar viruses and symptom clusters. The availability of reagents for diagnostic development (virus strains and antigens, quantified viral ribonucleic acid) needs to be facilitated. Conclusion An international laboratory response is needed, including preparation of protocols for prospective studies to address the most pressing information needs. PMID:27516635

  17. Glucose-6-phosphate dehydrogenase laboratory assay: How, when, and why?

    PubMed

    Minucci, Angelo; Giardina, Bruno; Zuppi, Cecilia; Capoluongo, Ettore

    2009-01-01

    Glucose 6-phosphate dehydrogenase (G6PD) deficiency is the most common defect of red blood cells. Although some different laboratory techniques or methods are employed for the biochemical screening, a strict relationship between biochemists, clinicians, and molecular biologists is necessary for a definitive diagnosis. This article represents an overview on the current laboratory tests finalized to the screening or to the definitive diagnosis of G6PD-deficiency, underlying the problems regarding the biochemical and molecular identification of heterozygote females other than those regarding the standardization of the clinical and laboratory diagnostic procedures. Finally, this review is aimed to give a flow-chart for the complete diagnostic approach of G6PD-deficiency.

  18. Survey of the Diagnostic Retooling Process in National TB Reference Laboratories, with Special Focus on Rapid Speciation Tests Endorsed by WHO in 2007

    PubMed Central

    van Kampen, Sanne C.; Oskam, Linda; Tuijn, Coosje J.; Klatser, Paul R.

    2012-01-01

    Background Successful integration of new diagnostics in national tuberculosis (TB) control programs, also called ‘retooling’, is highly dependent on operational aspects related to test availability, accessibility and affordability. This survey aimed to find out whether recommendations to use new diagnostics lead to successful retooling in high TB endemic countries, using immunochromatographic tests (ICTs) for TB culture speciation as a case study. ICTs are recommended to accurately confirm the presence of bacteria of the Mycobacterium tuberculosis complex in liquid culture isolates. Methods and Findings Questionnaires were sent to national TB reference laboratories (NRLs) in 42 high TB endemic countries to address their access to information on ICT implementation, logistics related to availability, accessibility and affordability of ICTs, and testing algorithms. Results from 16 responding countries indicated that half of the NRLs were aware of the contents of WHO guidance documents on liquid culture and ICT implementation, as well as their eligibility for a negotiated pricing agreement for ICT procurement. No major issues with availability and accessibility of ICTs were raised. When asked about testing algorithms, ICTs were not used as stand-alone or first test for TB culture identification as recommended by WHO. Conclusions The low response rate was a limitation of this survey and together with NRLs managers' unawareness of global guidance, suggests a lack of effective communication between partners of the global laboratory network and NRLs. TB tests could become more affordable to high TB endemic countries, if the possibility to negotiate lower prices for commercial products is communicated to them more successfully. NRLs need additional guidance to identify where available technologies can be most usefully implemented and in what order, taking into account long-term laboratory strategies. PMID:22937050

  19. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories

    PubMed Central

    Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N’Faly; Martel, Lise D.; Dahourou, Anicet George

    2017-01-01

    Background Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Methods and findings Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. Conclusions The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation. PMID:29190713

  20. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    PubMed

    VanSteelandt, Amanda; Aho, Josephine; Franklin, Kristyn; Likofata, Jacques; Kamgang, Jean Baptiste; Keita, Sakoba; Koivogui, Lamine; Magassouba, N'Faly; Martel, Lise D; Dahourou, Anicet George

    2017-01-01

    Rapid Diagnostic Tests (RDTs) for Ebola Virus Disease (EVD) at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program. Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1) a technical questionnaire filled by the lab technicians who performed the RDTs, (2) a checklist filled by the evaluator during the site visits, and (3) direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8%) expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8) but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program. The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  1. Advances Afoot in Microbiology

    PubMed Central

    Karon, Brad S.

    2017-01-01

    ABSTRACT In 2016, the American Academy of Microbiology convened a colloquium to examine point-of-care (POC) microbiology testing and to evaluate its effects on clinical microbiology. Colloquium participants included representatives from clinical microbiology laboratories, industry, and the government, who together made recommendations regarding the implementation, oversight, and evaluation of POC microbiology testing. The colloquium report is timely and well written (V. Dolen et al., Changing Diagnostic Paradigms for Microbiology, 2017, https://www.asm.org/index.php/colloquium-reports/item/6421-changing-diagnostic-paradigms-for-microbiology?utm_source=Commentary&utm_medium=referral&utm_campaign=diagnostics). Emerging POC microbiology tests, especially nucleic acid amplification tests, have the potential to advance medical care. PMID:28539341

  2. Multicentre evaluation of a direct agglutination test prototype kit (DAT-LPC) for diagnosis of visceral leishmaniasis.

    PubMed

    Oliveira, E; Oliveira, D; Cardoso, F A; Barbosa, J R; Marcelino, A P; Dutra, T; Araujo, T; Fernandes, L; Duque, D; Rabello, A

    2017-12-01

    In this study, we assessed the sensitivity, specificity, and diagnostic accuracy of a previously developed direct agglutination test (DAT) using a freeze-dried antigen derived from Leishmania infantum promastigotes and composed in a prototype kit for visceral leishmaniasis (VL) diagnosis, named DAT-LPC. To evaluate DAT-LPC reproducibility, the kit was used to analyse 207 serum samples from VL patients and 80 serum samples from patients with other parasitic infections or healthy subjects in four laboratories from different public health institutions in Brazil. DAT-LPC showed sensitivity between 96·2 and 99·5% (P = 0·14), specificity ranging from 96·2 to 97·5% (P = 0·95), and diagnostic accuracy ranging from 96·5 to 99% (P = 0·34). The inter-laboratory reproducibility of qualitative results was classified as excellent (κ index: 0·94-0·97). The reproducibility of the end-titre results in relation to the reference laboratory, ranged from 31 to 85%. These results demonstrate an excellent performance of the DAT-LPC, and validate it for the diagnosis of VL that could replace the immunofluorescent antibody test as the routine diagnostic test in the Brazilian public health system.

  3. Laboratory simulation of space plasma phenomena*

    NASA Astrophysics Data System (ADS)

    Amatucci, B.; Tejero, E. M.; Ganguli, G.; Blackwell, D.; Enloe, C. L.; Gillman, E.; Walker, D.; Gatling, G.

    2017-12-01

    Laboratory devices, such as the Naval Research Laboratory's Space Physics Simulation Chamber, are large-scale experiments dedicated to the creation of large-volume plasmas with parameters realistically scaled to those found in various regions of the near-Earth space plasma environment. Such devices make valuable contributions to the understanding of space plasmas by investigating phenomena under carefully controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. By working in collaboration with in situ experimentalists to create realistic conditions scaled to those found during the observations of interest, the microphysics responsible for the observed events can be investigated in detail not possible in space. To date, numerous investigations of phenomena such as plasma waves, wave-particle interactions, and particle energization have been successfully performed in the laboratory. In addition to investigations such as plasma wave and instability studies, the laboratory devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this presentation, we will describe several examples of the laboratory investigation of space plasma waves and instabilities and diagnostic development. *This work supported by the NRL Base Program.

  4. Selling biotechnology in the dental medicine marketplace: the OmniGene Diagnostics DNA probe tests for periodontal pathogens.

    PubMed

    Van Arsdell, S W; DiFronzo, F; Backman, K C; Mahler, P H

    1996-09-01

    OmniGene Diagnostics, Inc. has applied the principles of genetic engineering to develop species-specific DNA probe tests for eight periodontal pathogens (Porphyromonas gingivalis, Prevotella intermedia, Actinobacillus actinomycetem-comitans, Fusobacterium nucleatum, Eikenella corrodens, Campylobacter rectus, Bacteroides forsythus, and Treponema denticola). The test requires minimal effort on the part of the clinician: subgingival plaque samples are collected from the patient and sent through the mail for analysis by OmniGene Diagnostics' fully licensed clinical reference laboratory. Results are transmitted to the practitioner by phone, fax, or mail. The use of diagnostic tests for periodontal pathogens is a relatively new concept in dentistry and acceptance of the OmniGene Diagnostics tests by the dental marketplace has been slower than anticipated. OmniGene Diagnostics' challenge for the future is to persuade the dental community that monitoring periodontal pathogen levels, as well as other clinical indicators of disease, is essential to providing optimal care to the periodontitis patient.

  5. Molecular diagnostic methods for invasive fungal disease: the horizon draws nearer?

    PubMed

    Halliday, C L; Kidd, S E; Sorrell, T C; Chen, S C-A

    2015-04-01

    Rapid, accurate diagnostic laboratory tests are needed to improve clinical outcomes of invasive fungal disease (IFD). Traditional direct microscopy, culture and histological techniques constitute the 'gold standard' against which newer tests are judged. Molecular diagnostic methods, whether broad-range or fungal-specific, have great potential to enhance sensitivity and speed of IFD diagnosis, but have varying specificities. The use of PCR-based assays, DNA sequencing, and other molecular methods including those incorporating proteomic approaches such as matrix-assisted laser desorption ionisation-time of flight mass spectroscopy (MALDI-TOF MS) have shown promising results. These are used mainly to complement conventional methods since they require standardisation before widespread implementation can be recommended. None are incorporated into diagnostic criteria for defining IFD. Commercial assays may assist standardisation. This review provides an update of molecular-based diagnostic approaches applicable to biological specimens and fungal cultures in microbiology laboratories. We focus on the most common pathogens, Candida and Aspergillus, and the mucormycetes. The position of molecular-based approaches in the detection of azole and echinocandin antifungal resistance is also discussed.

  6. [Principles of cooperation between the specialties of internal medicine, pathology and clinical biochemistry].

    PubMed

    Hölzel, W; Baumgarten, R; Fiedler, H; Zimmermann, S

    1985-12-01

    The optimal utilization of the knowledge and possibilities of pathological and clinical biochemistry presumes a close cooperation between it and the clinical specialties. The common working team of the GDR Society of Internal Medicine and the GDR Society for Clinical Chemistry and Laboratory Diagnostics makes theses of the central points of the cooperation in care, education, further education and postgraduate study and in research a subject for discussion. As essential tasks in the process of medical care are regarded the balance of the examination programme standing at the disposal, the establishment of diagnostic programmes, the establishment of organisational measures, the ascertainment of a use according to indication, the guarantee of the representance of examination material, the control of plausibility and the interpretation of test results. Since the realization of the tasks to a large extent depends on the cooperation of the specialities in education, further education and postgraduate study during the further education the clinician should become acquainted with the possibilities, the limits and the prerequisites for the performance of laboratory diagnostic investigations, the clinical biochemist with the problems of medical care and the value of the laboratory diagnosis in the total process of the treatment. In the field of research the result is a necessary cooperation in the clarification of patho-biochemical mechanisms, in the search for suitable laboratory diagnostic parameters for diagnostics and control of the course as well as in the statement of the validity of laboratory diagnostic parameters and parameter combinations taking into consideration the factors expenses, benefit and risk as well as further diagnostic possibilities.

  7. Standardization of Laboratory Methods for the PERCH Study

    PubMed Central

    Karron, Ruth A.; Morpeth, Susan C.; Bhat, Niranjan; Levine, Orin S.; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Knoll, Maria Deloria; Kotloff, Karen L.; Madhi, Shabir A.; Scott, J. Anthony G.; Thea, Donald M.; Adrian, Peter V.; Ahmed, Dilruba; Alam, Muntasir; Anderson, Trevor P.; Antonio, Martin; Baillie, Vicky L.; Dione, Michel; Endtz, Hubert P.; Gitahi, Caroline; Karani, Angela; Kwenda, Geoffrey; Maiga, Abdoul Aziz; McClellan, Jessica; Mitchell, Joanne L.; Morailane, Palesa; Mugo, Daisy; Mwaba, John; Mwansa, James; Mwarumba, Salim; Nyongesa, Sammy; Panchalingam, Sandra; Rahman, Mustafizur; Sawatwong, Pongpun; Tamboura, Boubou; Toure, Aliou; Whistler, Toni; O’Brien, Katherine L.; Murdoch, David R.

    2017-01-01

    Abstract The Pneumonia Etiology Research for Child Health study was conducted across 7 diverse research sites and relied on standardized clinical and laboratory methods for the accurate and meaningful interpretation of pneumonia etiology data. Blood, respiratory specimens, and urine were collected from children aged 1–59 months hospitalized with severe or very severe pneumonia and community controls of the same age without severe pneumonia and were tested with an extensive array of laboratory diagnostic tests. A standardized testing algorithm and standard operating procedures were applied across all study sites. Site laboratories received uniform training, equipment, and reagents for core testing methods. Standardization was further assured by routine teleconferences, in-person meetings, site monitoring visits, and internal and external quality assurance testing. Targeted confirmatory testing and testing by specialized assays were done at a central reference laboratory. PMID:28575358

  8. Growth hormone stimulation test

    MedlinePlus

    ... Philadelphia, PA: Elsevier Saunders; 2016:chap 23. Chernecky CC, Berger BJ. Growth hormone (somatotropin, GH) and growth hormone-releasing hormone (GHRH) - blood. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . ...

  9. Standing of nucleic acid testing strategies in veterinary diagnosis laboratories to uncover Mycobacterium tuberculosis complex members

    PubMed Central

    Costa, Pedro; Botelho, Ana; Couto, Isabel; Viveiros, Miguel; Inácio, João

    2014-01-01

    Nucleic acid testing (NAT) designate any molecular approach used for the detection, identification, and characterization of pathogenic microorganisms, enabling the rapid, specific, and sensitive diagnostic of infectious diseases, such as tuberculosis. These assays have been widely used since the 90s of the last century in human clinical laboratories and, subsequently, also in veterinary diagnostics. Most NAT strategies are based in the polymerase chain reaction (PCR) and its several enhancements and variations. From the conventional PCR, real-time PCR and its combinations, isothermal DNA amplification, to the nanotechnologies, here we review how the NAT assays have been applied to decipher if and which member of the Mycobacterium tuberculosis complex is present in a clinical sample. Recent advances in DNA sequencing also brought new challenges and have made possible to generate rapidly and at a low cost, large amounts of sequence data. This revolution with the high-throughput sequencing (HTS) technologies makes whole genome sequencing (WGS) and metagenomics the trendiest NAT strategies, today. The ranking of NAT techniques in the field of clinical diagnostics is rising, and we provide a SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis with our view of the use of molecular diagnostics for detecting tuberculosis in veterinary laboratories, notwithstanding the gold standard being still the classical culture of the agent. The complementary use of both classical and molecular diagnostics approaches is recommended to speed the diagnostic, enabling a fast decision by competent authorities and rapid tackling of the disease. PMID:25988157

  10. Standing of nucleic acid testing strategies in veterinary diagnosis laboratories to uncover Mycobacterium tuberculosis complex members.

    PubMed

    Costa, Pedro; Botelho, Ana; Couto, Isabel; Viveiros, Miguel; Inácio, João

    2014-01-01

    Nucleic acid testing (NAT) designate any molecular approach used for the detection, identification, and characterization of pathogenic microorganisms, enabling the rapid, specific, and sensitive diagnostic of infectious diseases, such as tuberculosis. These assays have been widely used since the 90s of the last century in human clinical laboratories and, subsequently, also in veterinary diagnostics. Most NAT strategies are based in the polymerase chain reaction (PCR) and its several enhancements and variations. From the conventional PCR, real-time PCR and its combinations, isothermal DNA amplification, to the nanotechnologies, here we review how the NAT assays have been applied to decipher if and which member of the Mycobacterium tuberculosis complex is present in a clinical sample. Recent advances in DNA sequencing also brought new challenges and have made possible to generate rapidly and at a low cost, large amounts of sequence data. This revolution with the high-throughput sequencing (HTS) technologies makes whole genome sequencing (WGS) and metagenomics the trendiest NAT strategies, today. The ranking of NAT techniques in the field of clinical diagnostics is rising, and we provide a SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis with our view of the use of molecular diagnostics for detecting tuberculosis in veterinary laboratories, notwithstanding the gold standard being still the classical culture of the agent. The complementary use of both classical and molecular diagnostics approaches is recommended to speed the diagnostic, enabling a fast decision by competent authorities and rapid tackling of the disease.

  11. Tuberculous otitis media: a significant diagnostic challenge.

    PubMed

    Vaamonde, Pedro; Castro, Crisanto; García-Soto, Nicolas; Labella, Torcuato; Lozano, Ascensión

    2004-06-01

    This study was undertaken to revise the diagnostic characteristics of tuberculous otitis media (TOM), a disorder that is often diagnosed late, leading to delay in specific treatment. Retrospective study of a longitudinal series of 10 TOM patients over a 7-year period at an institutional referral center. Most patients showed intractable otorrhea, moderately severe hearing loss, and necrotic eardrums with granulation tissue and single perforations. Multiple perforations, facial palsy, and cervical adenopathies were rare (<10% of patients). CT generally showed soft tissue involvement of the middle ear without bone erosion. The most effective laboratory test microbiological culture of exudate (diagnostic efficacy 71%). Specific antibiotic treatment was effective in all cases. The diagnosis of TOM remains a significant challenge for otorhinolaryngologists. If there are strong clinical grounds for suspicion, standard laboratory tests for tuberculosis should be repeated even if initially negative.

  12. Leading Antibacterial Laboratory Research by Integrating Conventional and Innovative Approaches: The Laboratory Center of the Antibacterial Resistance Leadership Group.

    PubMed

    Manca, Claudia; Hill, Carol; Hujer, Andrea M; Patel, Robin; Evans, Scott R; Bonomo, Robert A; Kreiswirth, Barry N

    2017-03-15

    The Antibacterial Resistance Leadership Group (ARLG) Laboratory Center (LC) leads the evaluation, development, and implementation of laboratory-based research by providing scientific leadership and supporting standard/specialized laboratory services. The LC has developed a physical biorepository and a virtual biorepository. The physical biorepository contains bacterial isolates from ARLG-funded studies located in a centralized laboratory and they are available to ARLG investigators. The Web-based virtual biorepository strain catalogue includes well-characterized gram-positive and gram-negative bacterial strains published by ARLG investigators. The LC, in collaboration with the ARLG Leadership and Operations Center, developed procedures for review and approval of strain requests, guidance during the selection process, and for shipping strains from the distributing laboratories to the requesting investigators. ARLG strains and scientific and/or technical guidance have been provided to basic research laboratories and diagnostic companies for research and development, facilitating collaboration between diagnostic companies and the ARLG Master Protocol for Evaluating Multiple Infection Diagnostics (MASTERMIND) initiative for evaluation of multiple diagnostic devices from a single patient sampling event. In addition, the LC has completed several laboratory-based studies designed to help evaluate new rapid molecular diagnostics by developing, testing, and applying a MASTERMIND approach using purified bacterial strains. In collaboration with the ARLG's Statistical and Data Management Center (SDMC), the LC has developed novel analytical strategies that integrate microbiologic and genetic data for improved and accurate identification of antimicrobial resistance. These novel approaches will aid in the design of future ARLG studies and help correlate pathogenic markers with clinical outcomes. The LC's accomplishments are the result of a successful collaboration with the ARLG's Leadership and Operations Center, Diagnostics and Devices Committee, and SDMC. This interactive approach has been pivotal for the success of LC projects. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  13. Molecular diagnostics: the changing culture of medical microbiology.

    PubMed

    Bullman, Susan; Lucey, Brigid; Sleator, Roy D

    2012-01-01

    Diagnostic molecular biology is arguably the fastest growing area in current laboratory-based medicine. Growth of the so called 'omics' technologies has, over the last decade, led to a gradual migration away from the 'one test, one pathogen' paradigm, toward multiplex approaches to infectious disease diagnosis, which have led to significant improvements in clinical diagnostics and ultimately improved patient care.

  14. Evaluating Malaria Prevalence Using Clinical Diagnosis Compared with Microscopy and Rapid Diagnostic Tests in a Tertiary Healthcare Facility in Rivers State, Nigeria.

    PubMed

    Wogu, M N; Nduka, F O

    2018-01-01

    The World Health Organization's policy on laboratory test of all suspected malaria cases before treatment has not yielded significant effects in several rural areas of Sub-Saharan Africa due to inadequate diagnostic infrastructure, leading to high morbidity and mortality rates. A cross-sectional randomized study was conducted to evaluate the validity of clinical malaria diagnosis through comparison with microscopy and rapid diagnostic test kits (RDTs) using 1000 consenting outpatients of a tertiary hospital in Nigeria. Physicians conducted clinical diagnosis, and blood samples were collected through venous procedure and analyzed for malaria parasites using Giemsa microscopy and RDT kits. Microscopy was considered the diagnostic "gold standard" and all data obtained were statistically analyzed using Chi-square test with a P value <0.05 considered significant. Malaria prevalence values of 20.1%, 43.1%, and 29.7% were obtained for clinical diagnosis, microscopy, and RDTs, respectively ( P < 0.05). Values of 47.2%, 95.9%, and 77.8% were obtained for sensitivity, specificity, and diagnostic accuracy, respectively, in clinical diagnosis, while RDTs had sensitivity, specificity, and diagnostic accuracy values of 73.7%, 97.3%, and 88.3%, respectively, when compared to microscopy ( P < 0.05). Clinical diagnosed malaria cases should be confirmed with a parasite-based laboratory diagnosis and more qualitative research is needed to explore why clinicians still use clinical diagnosis despite reported cases of its ineffectiveness.

  15. The role of standards in the development and implementation of clinical laboratory tests: a domestic and global perspective.

    PubMed

    Michaud, Ginette Y

    2005-01-01

    In the field of clinical laboratory medicine, standardization is aimed at increasing the trueness and reliability of measured values. Standardization relies on the use of written standards, reference measurement procedures and reference materials. These are important tools for the design and validation of new tests, and for establishing the metrological traceability of diagnostic assays. Their use supports the translation of research technologies into new diagnostic assays and leads to more rapid advances in science and medicine, as well as improvements in the quality of patient care. The various standardization tools are described, as are the procedures by which written standards, reference procedures and reference materials are developed. Recent efforts to develop standards for use in the field of molecular diagnostics are discussed. The recognition of standardization tools by the FDA and other regulatory authorities is noted as evidence of their important role in ensuring the safety and performance of in vitro diagnostic devices.

  16. Deployment of a Reverse Transcription Loop-Mediated Isothermal Amplification Test for Ebola Virus Surveillance in Remote Areas in Guinea.

    PubMed

    Kurosaki, Yohei; Magassouba, N'Faly; Bah, Hadja Aïssatou; Soropogui, Barré; Doré, Amadou; Kourouma, Fodé; Cherif, Mahamoud Sama; Keita, Sakoba; Yasuda, Jiro

    2016-10-15

    To strengthen the laboratory diagnostic capacity for Ebola virus disease (EVD) in the remote areas of Guinea, we deployed a mobile field laboratory and implemented reverse transcription loop-mediated isothermal amplification (RT-LAMP) for postmortem testing. We tested 896 oral swab specimens and 21 serum samples, using both RT-LAMP and reverse transcription-polymerase chain reaction (RT-PCR). Neither test yielded a positive result, and the results from RT-LAMP and RT-PCR were consistent. More than 95% of the samples were tested within 2 days of sample collection. These results highlight the usefulness of the RT-LAMP assay as an EVD diagnostic testing method in the field or remote areas. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  17. Particles and microfluidics merged: perspectives of highly sensitive diagnostic detection

    PubMed Central

    Bale, Shyam Sundhar; Bhushan, Abhinav; Shen, Keyue; Seker, Erkin; Polyak, Boris

    2014-01-01

    There is a growing need for diagnostic technologies that provide laboratories with solutions that improve quality, enhance laboratory system productivity, and provide accurate detection of a broad range of infectious diseases and cancers. Recent advances in micro- and nanoscience and engineering, in particular in the areas of particles and microfluidic technologies, have advanced the “lab-on-a-chip” concept towards the development of a new generation of point-of-care diagnostic devices that could significantly enhance test sensitivity and speed. In this review, we will discuss many of the recent advances in microfluidics and particle technologies with an eye towards merging these two technologies for application in medical diagnostics. Although the potential diagnostic applications are virtually unlimited, the most important applications are foreseen in the areas of biomarker research, cancer diagnosis, and detection of infectious microorganisms. PMID:25378716

  18. Performance specifications for the extra-analytical phases of laboratory testing: Why and how.

    PubMed

    Plebani, Mario

    2017-07-01

    An important priority in the current healthcare scenario should be to address errors in laboratory testing, which account for a significant proportion of diagnostic errors. Efforts made in laboratory medicine to enhance the diagnostic process have been directed toward improving technology, greater volumes and more accurate laboratory tests being achieved, but data collected in the last few years highlight the need to re-evaluate the total testing process (TTP) as the unique framework for improving quality and patient safety. Valuable quality indicators (QIs) and extra-analytical performance specifications are required for guidance in improving all TTP steps. Yet in literature no data are available on extra-analytical performance specifications based on outcomes, and nor is it possible to set any specification using calculations involving biological variability. The collection of data representing the state-of-the-art based on quality indicators is, therefore, underway. The adoption of a harmonized set of QIs, a common data collection and standardised reporting method is mandatory as it will not only allow the accreditation of clinical laboratories according to the International Standard, but also assure guidance for promoting improvement processes and guaranteeing quality care to patients. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Metagenomics: The Next Culture-Independent Game Changer

    PubMed Central

    Forbes, Jessica D.; Knox, Natalie C.; Ronholm, Jennifer; Pagotto, Franco; Reimer, Aleisha

    2017-01-01

    A trend towards the abandonment of obtaining pure culture isolates in frontline laboratories is at a crossroads with the ability of public health agencies to perform their basic mandate of foodborne disease surveillance and response. The implementation of culture-independent diagnostic tests (CIDTs) including nucleic acid and antigen-based assays for acute gastroenteritis is leaving public health agencies without laboratory evidence to link clinical cases to each other and to food or environmental substances. This limits the efficacy of public health epidemiology and surveillance as well as outbreak detection and investigation. Foodborne outbreaks have the potential to remain undetected or have insufficient evidence to support source attribution and may inadvertently increase the incidence of foodborne diseases. Next-generation sequencing of pure culture isolates in clinical microbiology laboratories has the potential to revolutionize the fields of food safety and public health. Metagenomics and other ‘omics’ disciplines could provide the solution to a cultureless future in clinical microbiology, food safety and public health. Data mining of information obtained from metagenomics assays can be particularly useful for the identification of clinical causative agents or foodborne contamination, detection of AMR and/or virulence factors, in addition to providing high-resolution subtyping data. Thus, metagenomics assays may provide a universal test for clinical diagnostics, foodborne pathogen detection, subtyping and investigation. This information has the potential to reform the field of enteric disease diagnostics and surveillance and also infectious diseases as a whole. The aim of this review will be to present the current state of CIDTs in diagnostic and public health laboratories as they relate to foodborne illness and food safety. Moreover, we will also discuss the diagnostic and subtyping utility and concomitant bias limitations of metagenomics and comparable detection techniques in clinical microbiology, food and public health laboratories. Early advances in the discipline of metagenomics, however, have indicated noteworthy challenges. Through forthcoming improvements in sequencing technology and analytical pipelines among others, we anticipate that within the next decade, detection and characterization of pathogens via metagenomics-based workflows will be implemented in routine usage in diagnostic and public health laboratories. PMID:28725217

  20. Performance of health laboratories in provision of HIV diagnostic and supportive services in selected districts of Tanzania.

    PubMed

    Ishengoma, Deus S; Kamugisha, Mathias L; Rutta, Acleus S M; Kagaruki, Gibson B; Kilale, Andrew M; Kahwa, Amos; Kamugisha, Erasmus; Baraka, Vito; Mandara, Celine I; Materu, Godlisten S; Massaga, Julius J; Magesa, Stephen M; Lemnge, Martha M; Mboera, Leonard E G

    2017-01-23

    Roll-out and implementation of antiretroviral therapy (ART) necessitated many countries in Sub-Saharan Africa to strengthen their national health laboratory systems (NHLSs) to provide high quality HIV diagnostic and supportive services. This study was conducted to assess the performance of health laboratories in provision of HIV diagnostic and supportive services in eight districts (from four regions of Iringa, Mtwara, Tabora and Tanga), after nine years of implementation of HIV/AIDS care and treatment plan in Tanzania. In this cross-sectional study, checklists and observations were utilized to collect information from health facilities (HFs) with care and treatment centres (CTCs) for HIV/AIDS patients; on availability of laboratories, CTCs, laboratory personnel, equipment and reagents. A checklist was also used to collect information on implementation of quality assurance (QA) systems at all levels of the NHLS in the study areas. The four regions had 354 HFs (13 hospitals, 41 Health Centres (HCs) and 300 dispensaries); whereby all hospitals had laboratories and 11 had CTCs while 97.5 and 61.0% of HCs had both laboratories and CTCs, respectively. Of the dispensaries, 36.0 and 15.0% had laboratories and CTCs (mainly in urban areas). Thirty nine HFs (12 hospitals, 21 HCs and six dispensaries) were assessed and 56.4% were located in urban areas. The assessed HFs had 199 laboratory staff of different cadres (laboratory assistants = 35.7%; technicians =32.7%; attendants = 22.6%; and others = 9.1%); with >61% of the staff and 72.3% of the technicians working in urban areas. All laboratories were using rapid diagnostic tests for HIV testing. Over 74% of the laboratories were performing internal quality control and 51.4% were participating in external QA programmes. Regional and district laboratories had all key equipment and harmonization was maintained for Fluorescence-Activated Cell Sorting (FACS) machines. Most of the biochemical (58.0%) and haematological analysers (74.1%) were available in urban areas. Although >81% of the equipment were functional with no mechanical faulty, 62.6% had not been serviced in the past three years. Diagnostic and supportive services for HIV were available in most of the HCs and hospitals while few dispensaries were providing the services. Due to limitations such as shortage of staff, serving of equipment and participation in QA programmes, the NHLS should be strengthened to ensure adequate human resource, implementation of QA and sustainable preventive maintenance services of equipment.

  1. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Specificity tests and avidity tests. 660.26... (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.26 Specificity tests and avidity tests. Specificity and avidity tests shall be performed...

  2. TESTING PRACTICES AND VOLUME OF NON-LYME TICKBORNE DISEASES IN THE UNITED STATES

    PubMed Central

    Connally, Neeta P.; Hinckley, Alison F.; Feldman, Katherine A.; Kemperman, Melissa; Neitzel, David; Wee, Siok-Bi; White, Jennifer L.; Mead, Paul S.; Meek, James I.

    2015-01-01

    Large commercial laboratories in the United States were surveyed regarding the number of specimens tested for eight tickborne diseases in 2008. Seven large commercial laboratories reported testing a total of 2,927,881 specimens nationally (including Lyme disease). Of these, 495,585 specimens (17 percent) were tested for tickborne diseases other than Lyme disease. In addition to large commercial laboratories, another 1,051 smaller commercial, hospital, and government laboratories in four states (CT, MD, MN, and NY) were surveyed regarding tickborne disease testing frequency, practices, and results. Ninety-two of these reported testing a total of 10,091 specimens for four tickborne diseases other than Lyme disease. We estimate the cost of laboratory diagnostic testing for non-Lyme disease tickborne diseases in 2008 to be $9.6 million. These data provide a baseline to evaluate trends in tickborne disease test utilization and insight into the burden of these diseases. PMID:26565931

  3. External quality assurance of HER2 fluorescence in situ hybridisation testing: results of a UK NEQAS pilot scheme

    PubMed Central

    Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith

    2007-01-01

    Background and Aims Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over‐express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. Methods FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Results Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. Conclusions The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the “real world”. PMID:16963466

  4. When BVD doesn't look like BVD

    USDA-ARS?s Scientific Manuscript database

    Due to the sheer number of different clinical presentations existing under the BVD umbrella, diagnosing BVD based on clinical signs is not advisable. Thus diagnosis relies upon testing of samples in diagnostic laboratories. In the US, most of the diagnostic effort has been focused on identifying a...

  5. Rapid deployment of a mobile biosafety level-3 laboratory in Sierra Leone during the 2014 Ebola virus epidemic

    PubMed Central

    Zhang, Yi; Gong, Yan; Wang, Chengyu; Liu, Wensen; Wang, Zhongyi; Xia, Zhiping; Bu, Zhaoyang; Lu, Huijun; Sun, Yang; Zhang, Xiaoguang; Cao, Yuxi; Yang, Fan; Su, Haoxiang; Hu, Yi; Deng, Yongqiang; Zhou, Bo; Zhao, Zongzheng; Fu, Yingying; Kargbo, David; Dafae, Foday; Kargbo, Brima; Kanu, Alex; Qian, Jun; Guo, Zhendong

    2017-01-01

    Background Ebola virus emerged in West Africa in December 2013. The high population mobility and poor public health infrastructure in this region led to the development of the largest Ebola virus disease (EVD) outbreak to date. Methodology/Principal findings On September 26, 2014, China dispatched a Mobile Biosafety Level-3 Laboratory (MBSL-3 Lab) and a well-trained diagnostic team to Sierra Leone to assist in EVD diagnosis using quantitative real-time PCR, which allowed the diagnosis of suspected EVD cases in less than 4 hours from the time of sample receiving. This laboratory was composed of three container vehicles equipped with advanced ventilation system, communication system, electricity and gas supply system. We strictly applied multiple safety precautions to reduce exposure risks. Personnel, materials, water and air flow management were the key elements of the biosafety measures in the MBSL-3 Lab. Air samples were regularly collected from the MBSL-3 Lab, but no evidence of Ebola virus infectious aerosols was detected. Potentially contaminated objects were also tested by collecting swabs. On one occasion, a pipette tested positive for EVD. A total of 1,635 suspected EVD cases (824 positive [50.4%]) were tested from September 28 to November 11, 2014, and no member of the diagnostic team was infected with Ebola virus or other pathogens, including Lassa fever. The specimens tested included blood (69.2%) and oral swabs (30.8%) with positivity rates of 54.2% and 41.9%, respectively. The China mobile laboratory was thus instrumental in the EVD outbreak response by providing timely and reliable diagnostics. Conclusions/Significance The MBSL-3 Lab significantly contributed to establishing a suitable laboratory response capacity during the emergence of EVD in Sierra Leone. PMID:28505171

  6. Rapid deployment of a mobile biosafety level-3 laboratory in Sierra Leone during the 2014 Ebola virus epidemic.

    PubMed

    Zhang, Yi; Gong, Yan; Wang, Chengyu; Liu, Wensen; Wang, Zhongyi; Xia, Zhiping; Bu, Zhaoyang; Lu, Huijun; Sun, Yang; Zhang, Xiaoguang; Cao, Yuxi; Yang, Fan; Su, Haoxiang; Hu, Yi; Deng, Yongqiang; Zhou, Bo; Zhao, Zongzheng; Fu, Yingying; Kargbo, David; Dafae, Foday; Kargbo, Brima; Kanu, Alex; Liu, Linna; Qian, Jun; Guo, Zhendong

    2017-05-01

    Ebola virus emerged in West Africa in December 2013. The high population mobility and poor public health infrastructure in this region led to the development of the largest Ebola virus disease (EVD) outbreak to date. On September 26, 2014, China dispatched a Mobile Biosafety Level-3 Laboratory (MBSL-3 Lab) and a well-trained diagnostic team to Sierra Leone to assist in EVD diagnosis using quantitative real-time PCR, which allowed the diagnosis of suspected EVD cases in less than 4 hours from the time of sample receiving. This laboratory was composed of three container vehicles equipped with advanced ventilation system, communication system, electricity and gas supply system. We strictly applied multiple safety precautions to reduce exposure risks. Personnel, materials, water and air flow management were the key elements of the biosafety measures in the MBSL-3 Lab. Air samples were regularly collected from the MBSL-3 Lab, but no evidence of Ebola virus infectious aerosols was detected. Potentially contaminated objects were also tested by collecting swabs. On one occasion, a pipette tested positive for EVD. A total of 1,635 suspected EVD cases (824 positive [50.4%]) were tested from September 28 to November 11, 2014, and no member of the diagnostic team was infected with Ebola virus or other pathogens, including Lassa fever. The specimens tested included blood (69.2%) and oral swabs (30.8%) with positivity rates of 54.2% and 41.9%, respectively. The China mobile laboratory was thus instrumental in the EVD outbreak response by providing timely and reliable diagnostics. The MBSL-3 Lab significantly contributed to establishing a suitable laboratory response capacity during the emergence of EVD in Sierra Leone.

  7. Current methods of laboratory diagnosis of Chlamydia trachomatis infections.

    PubMed Central

    Black, C M

    1997-01-01

    Infections caused by Chlamydia trachomatis are probably the most common sexually transmitted diseases in the United States. Commonly unrecognized and often inadequately treated, chlamydial infections can ascend the reproductive tract and cause pelvic inflammatory disease, which often results in the devastating consequences of infertility, ectopic pregnancy, or chronic pelvic pain. C. trachomatis infections are also known to increase the risk for human immunodeficiency virus infection. The obligate intracellular life cycle of C. trachomatis has traditionally required laboratory diagnostic tests that are technically demanding, labor-intensive, expensive, and difficult to access. In spite of these historical challenges, however, laboratory diagnosis of C. trachomatis has been a rapidly advancing area in which there is presently a wide array of commercial diagnostic technologies, costs, manufacturers. This review describes and compares the diagnostic methods for C. trachomatis infection that are currently approved for use in the United States, including the newest DNA amplification technologies which are yet to be licensed for commercial use. Issues to consider in selecting a test for purposes of screening versus diagnosis based on prevalence, performance, legal, social, and cost issues are also discussed. PMID:8993862

  8. Magnesium blood test

    MedlinePlus

    ... serum. In: Chernecky CC, Berger BJ, eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:750-751. Klemm KM, Klein MJ. Biochemical markers of bone metabolism. In: McPherson RA, Pincus ...

  9. Tests and calibration of NIF neutron time of flight detectors.

    PubMed

    Ali, Z A; Glebov, V Yu; Cruz, M; Duffy, T; Stoeckl, C; Roberts, S; Sangster, T C; Tommasini, R; Throop, A; Moran, M; Dauffy, L; Horsefield, C

    2008-10-01

    The National Ignition Facility (NIF) neutron time of flight (NTOF) diagnostic will measure neutron yield and ion temperature in all NIF campaigns in DD, DT, and THD(*) implosions. The NIF NTOF diagnostic is designed to measure neutron yield from 1x10(9) to 2x10(19). The NTOF consists of several detectors of varying sensitivity located on the NIF at about 5 and 20 m from the target. Production, testing, and calibration of the NIF NTOF detectors have begun at the Laboratory for Laser Energetics (LLE). Operational tests of the NTOF detectors were performed on several facilities including the OMEGA laser at LLE and the Titan laser at Lawrence Livermore National Laboratory. Neutron calibrations were carried out on the OMEGA laser. Results of the NTOF detector tests and calibration will be presented.

  10. Progress in the molecular diagnosis of Lyme disease.

    PubMed

    Ružić-Sabljić, Eva; Cerar, Tjaša

    2017-01-01

    Current laboratory testing of Lyme borreliosis mostly relies on serological methods with known limitations. Diagnostic modalities enabling direct detection of pathogen at the onset of the clinical signs could overcome some of the limitations. Molecular methods detecting borrelial DNA seem to be the ideal solution, although there are some aspects that need to be considered. Areas covered: This review represent summary and discussion of the published data obtained from literature searches from PubMed and The National Library of Medicine (USA) together with our own experience on molecular diagnosis of Lyme disease. Expert commentary: Molecular methods are promising and currently serve as supporting diagnostic testing in Lyme borreliosis. Since the field of molecular diagnostics is under rapid development, molecular testing could become an important diagnostic modality.

  11. Alchemy: A Web 2.0 Real-time Quality Assurance Platform for Human Immunodeficiency Virus, Hepatitis C Virus, and BK Virus Quantitation Assays.

    PubMed

    Agosto-Arroyo, Emmanuel; Coshatt, Gina M; Winokur, Thomas S; Harada, Shuko; Park, Seung L

    2017-01-01

    The molecular diagnostics laboratory faces the challenge of improving test turnaround time (TAT). Low and consistent TATs are of great clinical and regulatory importance, especially for molecular virology tests. Laboratory information systems (LISs) contain all the data elements necessary to do accurate quality assurance (QA) reporting of TAT and other measures, but these reports are in most cases still performed manually: a time-consuming and error-prone task. The aim of this study was to develop a web-based real-time QA platform that would automate QA reporting in the molecular diagnostics laboratory at our institution, and minimize the time expended in preparing these reports. Using a standard Linux, Nginx, MariaDB, PHP stack virtual machine running atop a Dell Precision 5810, we designed and built a web-based QA platform, code-named Alchemy. Data files pulled periodically from the LIS in comma-separated value format were used to autogenerate QA reports for the human immunodeficiency virus (HIV) quantitation, hepatitis C virus (HCV) quantitation, and BK virus (BKV) quantitation. Alchemy allowed the user to select a specific timeframe to be analyzed and calculated key QA statistics in real-time, including the average TAT in days, tests falling outside the expected TAT ranges, and test result ranges. Before implementing Alchemy, reporting QA for the HIV, HCV, and BKV quantitation assays took 45-60 min of personnel time per test every month. With Alchemy, that time has decreased to 15 min total per month. Alchemy allowed the user to select specific periods of time and analyzed the TAT data in-depth without the need of extensive manual calculations. Alchemy has significantly decreased the time and the human error associated with QA report generation in our molecular diagnostics laboratory. Other tests will be added to this web-based platform in future updates. This effort shows the utility of informatician-supervised resident/fellow programming projects as learning opportunities and workflow improvements in the molecular laboratory.

  12. Collection and Characterization of Samples for Establishment of a Serum Repository for Lyme Disease Diagnostic Test Development and Evaluation

    PubMed Central

    Molins, Claudia R.; Sexton, Christopher; Young, John W.; Ashton, Laura V.; Pappert, Ryan; Beard, Charles B.

    2014-01-01

    Serological assays and a two-tiered test algorithm are recommended for laboratory confirmation of Lyme disease. In the United States, the sensitivity of two-tiered testing using commercially available serology-based assays is dependent on the stage of infection and ranges from 30% in the early localized disease stage to near 100% in late-stage disease. Other variables, including subjectivity in reading Western blots, compliance with two-tiered recommendations, use of different first- and second-tier test combinations, and use of different test samples, all contribute to variation in two-tiered test performance. The availability and use of sample sets from well-characterized Lyme disease patients and controls are needed to better assess the performance of existing tests and for development of improved assays. To address this need, the Centers for Disease Control and Prevention and the National Institutes of Health prospectively collected sera from patients at all stages of Lyme disease, as well as healthy donors and patients with look-alike diseases. Patients and healthy controls were recruited using strict inclusion and exclusion criteria. Samples from all included patients were retrospectively characterized by two-tiered testing. The results from two-tiered testing corroborated the need for novel and improved diagnostics, particularly for laboratory diagnosis of earlier stages of infection. Furthermore, the two-tiered results provide a baseline with samples from well-characterized patients that can be used in comparing the sensitivity and specificity of novel diagnostics. Panels of sera and accompanying clinical and laboratory testing results are now available to Lyme disease serological test users and researchers developing novel tests. PMID:25122862

  13. A comprehensive assessment of the malaria microscopy system of Aceh, Indonesia, in preparation for malaria elimination.

    PubMed

    Ekawati, Lenny L; Herdiana, Herdiana; Sumiwi, Maria E; Barussanah, Cut; Ainun, Cut; Sabri, Sabri; Maulana, Teuku; Rahmadyani, Rahmadyani; Maneh, Cut; Yani, Muhammad; Valenti, Paola; Elyazar, Iqbal R F; Hawley, William A

    2015-06-11

    The Health Office of Aceh aims to eliminate malaria from Aceh Province, Indonesia by 2015. Malaria was formerly common in Aceh (population 4.5 million), but has declined dramatically in recent years consequent to post-tsunami control efforts. Successful elimination will depend upon rapid and accurate diagnosis and case follow-up at community level. A prerequisite to this is widespread coverage of high quality malaria diagnosis. This study describes the results of a comprehensive assessment of the malaria diagnostic capacity in Aceh as the province moves towards malaria elimination. The study was conducted in 23 districts in Aceh from October 2010 to July 2011. Six types of questionnaires were used to collect data on competency of microscopists and laboratory capacity. Standardized slides were used to evaluate the proficiency of all microscopists. In addition, site visits to 17 primary health centres (PHC) assessed diagnostic practice and logistics capacity. Five hundred and seventy four malaria microscopists have been officially registered and assigned to duty in the 23 districts in Aceh Province. They work in 345 laboratories, predominantly in PHCs (69 %) and hospitals (25 %). Three laboratories were evaluated as adequate for all 30 elements, while 29 laboratories were adequate for less than five of 30 elements. Standardized proficiency tests showed that 413 microscopists were at basic (in training) level, with 10 advanced and 9 reference level. No microscopist achieved expert level. Neither the province nor any of Aceh's districts has a standardized inventory and logistics database for malaria diagnostics, nor did any of the surveyed laboratories operate a quality assurance programme for either microscopy or rapid diagnostic tests. The study highlights the importance of careful assessment of diagnostic capacity when embarking upon a large-scale malaria elimination programme. Aceh's laboratories have minimal infrastructure with nearly all microscopists still in training. On the positive side, a large workforce of microscopists has been assigned to laboratories with the needed equipment. Aceh will need to embark on a large-scale comprehensive quality assurance scheme if it is to achieve malaria elimination.

  14. Advances Afoot in Microbiology.

    PubMed

    Patel, Robin; Karon, Brad S

    2017-07-01

    In 2016, the American Academy of Microbiology convened a colloquium to examine point-of-care (POC) microbiology testing and to evaluate its effects on clinical microbiology. Colloquium participants included representatives from clinical microbiology laboratories, industry, and the government, who together made recommendations regarding the implementation, oversight, and evaluation of POC microbiology testing. The colloquium report is timely and well written (V. Dolen et al., Changing Diagnostic Paradigms for Microbiology , 2017, https://www.asm.org/index.php/colloquium-reports/item/6421-changing-diagnostic-paradigms-for-microbiology?utm_source=Commentary&utm_medium=referral&utm_campaign=diagnostics). Emerging POC microbiology tests, especially nucleic acid amplification tests, have the potential to advance medical care. Copyright © 2017 American Society for Microbiology.

  15. Diagnostic Yield of Laboratory Methods and Value of Viral Genotyping during an Outbreak of Mumps in a Partially Vaccinated Population in British Columbia, Canada.

    PubMed

    Nunn, Alexandra; Masud, Shazia; Krajden, Mel; Naus, Monika; Jassem, Agatha N

    2018-05-01

    Mumps remains endemic in North America despite routine use of the measles, mumps, and rubella (MMR) vaccine. In 2016, an outbreak of mumps in British Columbia, Canada, provided an opportunity to determine the diagnostic utility of laboratory testing methods. Specimens from patients with clinical mumps were tested for infection using a commercial enzyme-linked immunosorbent assay (ELISA) for antibody detection and an in-house reverse transcriptase PCR (RT-PCR) targeting viral fusion and small hydrophobic (SH) genes. Viral genotyping was performed by SH gene sequencing. Laboratory data was linked with epidemiologic case data. Of the 139 confirmed cases, 94 (68%) had reported or documented history of MMR vaccination. Specimens were typically collected 1 day (for buccal and IgM tests) or 2 days (for urine tests) after symptom onset. Most confirmed cases (69%) were confirmed by buccal swab RT-PCR. Among cases tested by multiple methods, the percent positivity for buccal swab RT-PCR was 90% (96/107) compared to 43% (30/69) for both IgM ELISA and urine RT-PCR. Mumps IgM detection was higher in confirmed cases with no history of vaccination than in those with history (64% versus 34%, P = 0.02). The outbreak strain was identified as genotype G related to MuVi/Sheffield.GBR/1.05 but with conserved variations in five nucleotides within the SH gene that allowed linkage of geographically distinct cases. In conclusion, RT-PCR of buccal specimens had the highest diagnostic yield during a mumps outbreak in a partially vaccinated population. To optimize mumps diagnostic potential, clinicians should collect specimens depending on when the patient presents for care and their immunization history. © Crown copyright 2018.

  16. Changing needs, opportunities and constraints for the 21st century microbiology laboratory.

    PubMed

    Van Eldere, J

    2005-04-01

    Clinical microbiologists and microbiology laboratories are experiencing changes due to evolving views on 'healthcare delivery' as an economic activity, due to changes in the medical environment and the demographics of the workforce, and technical evolution. Cost-effectiveness of laboratory procedures has been achieved through consolidation and integration of laboratories. Consolidation offers economy of scale and reduction in numbers of on-site staff, but also leads to separation of microbiologists from their clinical colleagues. Integration puts different laboratory disciplines under a single management, and leads to reorganisation of laboratories along common work-lines. Cost-savings combined with on-site availability of laboratories are achieved at the expense of a reduction in the influence of microbiologists in the daily running of the laboratory. Medically, there is growing emphasis on evidence-based diagnostics. Because of time-delays inherent in culturing, microbiology through rapid testing is mandatory. There is an increasing shortage in Europe and the USA of trained microbiology laboratory technicians and microbiologists. This reinforces the trend towards more automation and integration. Technological advances, particularly in molecular diagnostics, offer the possibility of rapid reporting and improvement of the impact of clinical microbiology on patient management. Molecular tests, however, fit perfectly the concept of an integrated laboratory and may further loosen the link between microbiologist and microbiology tests. The challenge for clinical microbiology will be to use new techniques to improve its cost-effectiveness and impact on infectious disease management. The future organisation of microbiology laboratories must support this but is itself of secondary importance. The training of future microbiologist must prepare them for this changing environment.

  17. Outbreak!: Teaching Clinical and Diagnostic Microbiology Methodologies with an Interactive Online Game

    ERIC Educational Resources Information Center

    Clark, Sherri; Smith, Geoffrey Battle

    2004-01-01

    Outbreak! is an online, interactive educational game that helps students and teachers learn and evaluate clinical microbiology skills. When the game was used in introductory microbiology laboratories, qualitative evaluation by students showed very positive responses and increased learning. Outbreak! allows students to design diagnostic tests and…

  18. Opportunities for Improved Serodiagnosis of Human Tuberculosis, Bovine Tuberculosis, and Paratuberculosis

    PubMed Central

    Wadhwa, Ashutosh; Hickling, Graham J.; Eda, Shigetoshi

    2012-01-01

    Mycobacterial infections—tuberculosis (TB), bovine tuberculosis (bTB), and Johne's disease (JD)—are major infectious diseases of both human and animals. Methods presently in use for diagnosis of mycobacterial infections include bacterial culture, nucleic acid amplification, tuberculin skin test, interferon-γ assay, and serology. Serological tests have several advantages over other methods, including short turn-around time, relatively simple procedures, and low cost. However, current serodiagnostic methods for TB, bTB and JD exhibit low sensitivity and/or specificity. Recent studies that have aimed to develop improved serodiagnostic tests have mostly focused on identifying useful species-specific protein antigens. A review of recent attempts to improve diagnostic test performance indicates that the use of multiple antigens can improve the accuracy of serodiagnosis of these mycobacterial diseases. Mycobacteria also produce a variety of species-specific nonprotein molecules; however, only a few such molecules (e.g., cord factor and lipoarabinomannan) have so far been evaluated for their effectiveness as diagnostic antigens. For TB and bTB, there has been recent progress in developing laboratory-free diagnostic methods. New technologies such as microfluidics and “Lab-on-Chip” are examples of promising new technologies that can underpin development of laboratory-free diagnostic devices for these mycobacterial infections. PMID:22720192

  19. Trichinella diagnostics and control: mandatory and best practices for ensuring food safety.

    PubMed

    Gajadhar, Alvin A; Pozio, Edoardo; Gamble, H Ray; Nöckler, Karsten; Maddox-Hyttel, Charlotte; Forbes, Lorry B; Vallée, Isabelle; Rossi, Patrizia; Marinculić, Albert; Boireau, Pascal

    2009-02-23

    Because of its role in human disease, there are increasing global requirements for reliable diagnostic and control methods for Trichinella in food animals to ensure meat safety and to facilitate trade. Consequently, there is a need for standardization of methods, programs, and best practices used in the control of Trichinella and trichinellosis. This review article describes the biology and epidemiology of Trichinella, and describes recommended test methods as well as modified and optimized procedures that are used in meat inspection programs. The use of ELISA for monitoring animals for infection in various porcine and equine pre- and post-slaughter programs, including farm or herd certification programs is also discussed. A brief review of the effectiveness of meat processing methods, such as freezing, cooking and preserving is provided. The importance of proper quality assurance and its application in all aspects of a Trichinella diagnostic system is emphasized. It includes the use of international quality standards, test validation and standardization, critical control points, laboratory accreditation, certification of analysts and proficiency testing. Also described, are the roles and locations of international and regional reference laboratories for trichinellosis where expert advice and support on research and diagnostics are available.

  20. Development and Validation of Targeted Next-Generation Sequencing Panels for Detection of Germline Variants in Inherited Diseases.

    PubMed

    Santani, Avni; Murrell, Jill; Funke, Birgit; Yu, Zhenming; Hegde, Madhuri; Mao, Rong; Ferreira-Gonzalez, Andrea; Voelkerding, Karl V; Weck, Karen E

    2017-06-01

    - The number of targeted next-generation sequencing (NGS) panels for genetic diseases offered by clinical laboratories is rapidly increasing. Before an NGS-based test is implemented in a clinical laboratory, appropriate validation studies are needed to determine the performance characteristics of the test. - To provide examples of assay design and validation of targeted NGS gene panels for the detection of germline variants associated with inherited disorders. - The approaches used by 2 clinical laboratories for the development and validation of targeted NGS gene panels are described. Important design and validation considerations are examined. - Clinical laboratories must validate performance specifications of each test prior to implementation. Test design specifications and validation data are provided, outlining important steps in validation of targeted NGS panels by clinical diagnostic laboratories.

  1. Verification of examination procedures in clinical laboratory for imprecision, trueness and diagnostic accuracy according to ISO 15189:2012: a pragmatic approach.

    PubMed

    Antonelli, Giorgia; Padoan, Andrea; Aita, Ada; Sciacovelli, Laura; Plebani, Mario

    2017-08-28

    Background The International Standard ISO 15189 is recognized as a valuable guide in ensuring high quality clinical laboratory services and promoting the harmonization of accreditation programmes in laboratory medicine. Examination procedures must be verified in order to guarantee that their performance characteristics are congruent with the intended scope of the test. The aim of the present study was to propose a practice model for implementing procedures employed for the verification of validated examination procedures already used for at least 2 years in our laboratory, in agreement with the ISO 15189 requirement at the Section 5.5.1.2. Methods In order to identify the operative procedure to be used, approved documents were identified, together with the definition of performance characteristics to be evaluated for the different methods; the examination procedures used in laboratory were analyzed and checked for performance specifications reported by manufacturers. Then, operative flow charts were identified to compare the laboratory performance characteristics with those declared by manufacturers. Results The choice of performance characteristics for verification was based on approved documents used as guidance, and the specific purpose tests undertaken, a consideration being made of: imprecision and trueness for quantitative methods; diagnostic accuracy for qualitative methods; imprecision together with diagnostic accuracy for semi-quantitative methods. Conclusions The described approach, balancing technological possibilities, risks and costs and assuring the compliance of the fundamental component of result accuracy, appears promising as an easily applicable and flexible procedure helping laboratories to comply with the ISO 15189 requirements.

  2. The 'real-world' impact of improved diagnostic techniques for Chlamydia trachomatis infection in Glasgow.

    PubMed

    Scoular, A; McCartney, R; Kinn, S; Carr, S; Walker, A

    2001-09-01

    In April 1997, the main chlamydia laboratory in Glasgow introduced ligase chain reaction (LCR) as its standard diagnostic test. The diagnostic effectiveness and health economic impact of introduction of LCR testing was assessed. Between April 1996 to March 2000, results of all chlamydia detection tests on genital specimens sent from general practitioners and the two main sexual healthcare providers (Genitourinary Medicine and Family Planning services) were reviewed. A preliminary economic assessment, inclusive of staff, reagents, consumables and laboratory overheads was conducted. Overall, testing activity increased four and a half times between 1996-97 and 1999-2000; the proportionate rise was greatest in general practice. Although chlamydia testing in both genders increased over the review period, testing activity rose disproportionately in women (59%, compared with a 31% increase in men). The overall Chlamydia trachomatis detection rate rose from 4.8% in 1996-97 to 7.8% in 1999-2000. Following introduction of LCR testing, an estimated additional 331 men and 844 women were diagnosed during the study period. The cost per additional diagnosis made was estimated at 162 Pounds for men and 263 Pounds for women. Substantial health gains are likely to be achieved, at both an individual and public health level, as a result of introduction of LCR testing for genital chlamydial infection.

  3. Factoring quality laboratory diagnosis into the malaria control agenda for sub-Saharan Africa.

    PubMed

    Aidoo, Michael

    2013-09-01

    Recent progress in malaria control in sub-Saharan Africa has been achieved primarily through provision of insecticide-treated nets, indoor residual spraying, and antimalarial drugs. Although these interventions are important, proper case identification and accurate measurement of their impact depend on quality diagnostic testing. Current availability of diagnostic testing for malaria in sub-Saharan Africa is inadequate to support disease management, prevention programs, and surveillance needs. Challenges faced include a dearth of skilled workforce, inadequate health systems infrastructure, and lack of political will. A coordinated approach to providing pre-service clinical and laboratory training together with systems that support a scale-up of laboratory services could provide means not only for effective malaria case management but also, management of non-malaria febrile illnesses, disease surveillance, and accurate control program evaluation. A synthesis of the challenges faced in ensuring quality malaria testing and how to include this information in the malaria control and elimination agenda are presented.

  4. Statistical analysis of Turbine Engine Diagnostic (TED) field test data

    NASA Astrophysics Data System (ADS)

    Taylor, Malcolm S.; Monyak, John T.

    1994-11-01

    During the summer of 1993, a field test of turbine engine diagnostic (TED) software, developed jointly by U.S. Army Research Laboratory and the U.S. Army Ordnance Center and School, was conducted at Fort Stuart, GA. The data were collected in conformance with a cross-over design, some of whose considerations are detailed. The initial analysis of the field test data was exploratory, followed by a more formal investigation. Technical aspects of the data analysis insights that were elicited are reported.

  5. IBS and Non-GI Functional Disorders

    MedlinePlus

    ... than is considered normal). Most diagnostic tests (laboratory tests, radiology, endoscopy, and isotope scans) are designed to identify structural problems, but not disorders of function. There are many examples of functional disorders in the gastrointestinal (GI) tract. ...

  6. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices.

    PubMed

    Verhees, Bart; van Kuijk, Kees; Simonse, Lianne

    2017-12-21

    Point-of-care testing (POCT)-laboratory tests performed with new mobile devices and online technologies outside of the central laboratory-is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP's network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre.

  7. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    PubMed

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  8. 21 CFR 660.4 - Potency test.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.4 Potency test. To be satisfactory for release, each filling of Antibody to Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Surface Antigen Panel and shall be sufficiently potent...

  9. 21 CFR 660.4 - Potency test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.4 Potency test. To be satisfactory for release, each filling of Antibody to Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Surface Antigen Panel and shall be sufficiently potent...

  10. 21 CFR 660.43 - Potency test.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.43 Potency test. To be satisfactory for release, each filling of Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Antiserum Panel and shall be sufficiently potent to be able to detect the...

  11. 21 CFR 660.43 - Potency test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.43 Potency test. To be satisfactory for release, each filling of Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Antiserum Panel and shall be sufficiently potent to be able to detect the...

  12. 21 CFR 660.4 - Potency test.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.4 Potency test. To be satisfactory for release, each filling of Antibody to Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Surface Antigen Panel and shall be sufficiently potent...

  13. 21 CFR 660.43 - Potency test.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.43 Potency test. To be satisfactory for release, each filling of Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Antiserum Panel and shall be sufficiently potent to be able to detect the...

  14. 21 CFR 660.4 - Potency test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.4 Potency test. To be satisfactory for release, each filling of Antibody to Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Surface Antigen Panel and shall be sufficiently potent...

  15. 21 CFR 660.43 - Potency test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.43 Potency test. To be satisfactory for release, each filling of Hepatitis B Surface Antigen shall be tested against the Reference Hepatitis B Antiserum Panel and shall be sufficiently potent to be able to detect the...

  16. Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application.

    PubMed

    Gong, Max M; Sinton, David

    2017-06-28

    Infectious diseases are a major global health issue. Diagnosis is a critical first step in effectively managing their spread. Paper-based microfluidic diagnostics first emerged in 2007 as a low-cost alternative to conventional laboratory testing, with the goal of improving accessibility to medical diagnostics in developing countries. In this review, we examine the advances in paper-based microfluidic diagnostics for medical diagnosis in the context of global health from 2007 to 2016. The theory of fluid transport in paper is first presented. The next section examines the strategies that have been employed to control fluid and analyte transport in paper-based assays. Tasks such as mixing, timing, and sequential fluid delivery have been achieved in paper and have enabled analytical capabilities comparable to those of conventional laboratory methods. The following section examines paper-based sample processing and analysis. The most impactful advancement here has been the translation of nucleic acid analysis to a paper-based format. Smartphone-based analysis is another exciting development with potential for wide dissemination. The last core section of the review highlights emerging health applications, such as male fertility testing and wearable diagnostics. We conclude the review with the future outlook, remaining challenges, and emerging opportunities.

  17. Rolling Out Xpert® MTB/RIF for TB Detection in HIV-Infected Populations:An Opportunity for Systems Strengthening.

    PubMed

    Pathmanathan, Ishani; Date, Anand; Coggin, William L; Nkengasong, John; Piatek, Amy S; Alexander, Heather

    2017-03-31

    To eliminate preventable deaths, disease and suffering due to tuberculosis (TB), improved diagnostic capacity is critical. The Cepheid Xpert ® MTB/RIF assay is recommended by the World Health Organization as the initial diagnostic test for people with suspected HIV-associated TB. However, despite high expectations, its scale-up in real-world settings has faced challenges, often due to the systems that support it. In this commentary we discuss needs and opportunities for systems strengthening to support widespread scale-up of Xpert ® MTB/RIF as they relate to each step within the TB diagnostic cascade, from finding presumptive patients, to collecting, transporting and testing sputum specimens, to reporting and receiving results, to initiating and monitoring treatment and, ultimately, to ensuring successful and timely treatment and cure. Investments in evidence-based interventions at each step along the cascade and within the system as a whole will augment not only the utility of Xpert ® MTB/RIF, but also the successful implementation of future diagnostic tests. Xpert ® MTB/RIF will only improve patient outcomes if optimally implemented within the context of strong TB programs and systems. Roll-out of this technology to people living with HIV and others in resource-limited settings offers the opportunity to leverage current TB and HIV laboratory, diagnostic and programmatic investments, while also addressing challenges and strengthening coordination between laboratory systems, laboratory-program interfaces, and TB-HIV program interfaces. If successful, the benefits of this tool could extend beyond progress towards global End TB Strategy goals, to improve system-wide capacity for global disease detection and control.

  18. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  19. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  20. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  1. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  2. 21 CFR 660.25 - Potency tests without reference preparations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... manufacturer's package insert using red blood cells showing heterozygous or diminished expression of the... SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.25 Potency tests without reference preparations. Products for which Reference Blood...

  3. Adoption of Lean Principles in a High-Volume Molecular Diagnostic Microbiology Laboratory

    PubMed Central

    Mitchell, P. Shawn; Mandrekar, Jayawant N.

    2014-01-01

    Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved. PMID:24829247

  4. Teaching pediatric laboratory medicine to pathology residents.

    PubMed

    Pysher, Theodore J; Bach, Philip R; Geaghan, Sharon M; Hamilton, Marilyn S; Laposata, Michael; Lockitch, Gillian; Brugnara, Carlo; Coffin, Cheryl M; Pasquali, Marzia; Rinaldo, Piero; Roberts, William L; Rutledge, Joe C; Ashwood, Edward R; Blaylock, Robert C; Campos, Joseph M; Goldsmith, Barbara; Jones, Patricia M; Lim, Megan; Meikle, A Wayne; Perkins, Sherrie L; Perry, Deborah A; Petti, Cathy A; Rogers, Beverly B; Steele, Paul E; Weiss, Ronald L; Woods, Gail

    2006-07-01

    Laboratory data are essential to the medical care of fetuses, infants, children, and adolescents. However, the performance and interpretation of laboratory tests on specimens from these patients, which may constitute a significant component of the workload in general hospitals and integrated health care systems as well as specialized perinatal or pediatric centers, present unique challenges to the clinical pathologist and the laboratory. Therefore, pathology residents should receive training in pediatric laboratory medicine. Children's Health Improvement through Laboratory Diagnostics, a group of pathologists and laboratory scientists with interest and expertise in pediatric laboratory medicine, convened a task force to develop a list of curriculum topics, key resources, and training experiences in pediatric laboratory medicine for trainees in anatomic and clinical pathology or straight clinical pathology residency programs and in pediatric pathology fellowship programs. Based on the experiences of 11 training programs, we have compiled a comprehensive list of pediatric topics in the areas of clinical chemistry, endocrinology, hematology, urinalysis, coagulation medicine, transfusion medicine, immunology, microbiology and virology, biochemical genetics, cytogenetics and molecular diagnostics, point of care testing, and laboratory management. This report also includes recommendations for training experiences and a list of key texts and other resources in pediatric laboratory medicine. Clinical pathologists should be trained to meet the laboratory medicine needs of pediatric patients and to assist the clinicians caring for these patients with the selection and interpretation of laboratory studies. This review helps program directors tailor their curricula to more effectively provide this training.

  5. Clonality Testing in Veterinary Medicine: A Review With Diagnostic Guidelines.

    PubMed

    Keller, S M; Vernau, W; Moore, P F

    2016-07-01

    The accurate distinction of reactive and neoplastic lymphoid proliferations can present challenges. Given the different prognoses and treatment strategies, a correct diagnosis is crucial. Molecular clonality assays assess rearranged lymphocyte antigen receptor gene diversity and can help differentiate reactive from neoplastic lymphoid proliferations. Molecular clonality assays are commonly used to assess atypical, mixed, or mature lymphoid proliferations; small tissue fragments that lack architecture; and fluid samples. In addition, clonality testing can be utilized to track neoplastic clones over time or across anatomic sites. Molecular clonality assays are not stand-alone tests but useful adjuncts that follow clinical, morphologic, and immunophenotypic assessment. Even though clonality testing provides valuable information in a variety of situations, the complexities and pitfalls of this method, as well as its dependency on the experience of the interpreter, are often understated. In addition, a lack of standardized terminology, laboratory practices, and interpretational guidelines hinders the reproducibility of clonality testing across laboratories in veterinary medicine. The objectives of this review are twofold. First, the review is intended to familiarize the diagnostic pathologist or interested clinician with the concepts, potential pitfalls, and limitations of clonality testing. Second, the review strives to provide a basis for future harmonization of clonality testing in veterinary medicine by providing diagnostic guidelines. © The Author(s) 2016.

  6. The SUCCESS model for laboratory performance and execution of rapid molecular diagnostics in patients with sepsis.

    PubMed

    Dekmezian, Mhair; Beal, Stacy G; Damashek, Mary Jane; Benavides, Raul; Dhiman, Neelam

    2015-04-01

    Successful performance and execution of rapid diagnostics in a clinical laboratory hinges heavily on careful validation, accurate and timely communication of results, and real-time quality monitoring. Laboratories must develop strategies to integrate diagnostics with stewardship and evidence-based clinical practice guidelines. We present a collaborative SUCCESS model for execution and monitoring of rapid sepsis diagnostics to facilitate timely treatment. Six months after execution of the Verigene Gram-Positive Blood Culture (BC-GP) and the AdvanDx PNA-FISH assays, data were collected on 579 and 28 episodes of bacteremia and fungemia, respectively. Clinical testing was executed using a SUCCESS model comprising the following components: stewardship, utilization of resources, core strategies, concierge services, education, support, and surveillance. Stewardship needs were identified by evaluating the specialty services benefiting from new testing. Utilization of resources was optimized by reviewing current treatment strategies and antibiogram and formulary options. Core strategies consisted of input from infectious disease leadership, pharmacy, and laboratory staff. Concierge services included automated Micro-eUpdate and physician-friendly actionable reports. Education modules were user-specific, and support was provided through a dedicated 24/7 microbiology hotline. Surveillance was performed by daily audit by the director. Using the SUCCESS model, the turnaround time for the detailed report with actionable guidelines to the physician was ∼3 hours from the time of culture positivity. The overall correlation between rapid methods and culture was 94% (546/579). Discrepant results were predominantly contaminants such as a coagulase-negative staphylococci or viridans streptococci in mixed cultures. SUCCESS is a cost-effective and easily adaptable model for clinical laboratories with limited stewardship resources.

  7. Use of diagnostic accuracy as a metric for evaluating laboratory proficiency with microarray assays using mixed-tissue RNA reference samples.

    PubMed

    Pine, P S; Boedigheimer, M; Rosenzweig, B A; Turpaz, Y; He, Y D; Delenstarr, G; Ganter, B; Jarnagin, K; Jones, W D; Reid, L H; Thompson, K L

    2008-11-01

    Effective use of microarray technology in clinical and regulatory settings is contingent on the adoption of standard methods for assessing performance. The MicroArray Quality Control project evaluated the repeatability and comparability of microarray data on the major commercial platforms and laid the groundwork for the application of microarray technology to regulatory assessments. However, methods for assessing performance that are commonly applied to diagnostic assays used in laboratory medicine remain to be developed for microarray assays. A reference system for microarray performance evaluation and process improvement was developed that includes reference samples, metrics and reference datasets. The reference material is composed of two mixes of four different rat tissue RNAs that allow defined target ratios to be assayed using a set of tissue-selective analytes that are distributed along the dynamic range of measurement. The diagnostic accuracy of detected changes in expression ratios, measured as the area under the curve from receiver operating characteristic plots, provides a single commutable value for comparing assay specificity and sensitivity. The utility of this system for assessing overall performance was evaluated for relevant applications like multi-laboratory proficiency testing programs and single-laboratory process drift monitoring. The diagnostic accuracy of detection of a 1.5-fold change in signal level was found to be a sensitive metric for comparing overall performance. This test approaches the technical limit for reliable discrimination of differences between two samples using this technology. We describe a reference system that provides a mechanism for internal and external assessment of laboratory proficiency with microarray technology and is translatable to performance assessments on other whole-genome expression arrays used for basic and clinical research.

  8. Chronic myelogenous leukemia: laboratory diagnosis and monitoring.

    PubMed

    Wang, Y L; Bagg, A; Pear, W; Nowell, P C; Hess, J L

    2001-10-01

    Rapid developments have occurred both in laboratory medicine and in therapeutic interventions for the management of patients with chronic myelogenous leukemia (CML). With a wide array of laboratory tests available, selecting the appropriate test for a specific diagnostic or therapeutic setting has become increasingly difficult. In this review, we first discuss, from the point of view of laboratory medicine, the advantages and disadvantages of several commonly used laboratory assays, including cytogenetics, fluorescence in situ hybridization (FISH), and qualitative and quantitative reverse transcriptase-polymerase chain reaction (RT-PCR). We then discuss, from the point of view of clinical care, the test(s) of choice for the most common clinical scenarios, including diagnosis and monitoring of the therapeutic response and minimal residual disease in patients treated with different therapies. The purpose of this review is to help clinicians and laboratory physicians select appropriate tests for the diagnosis and monitoring of CML, with the ultimate goal of improving the cost-effective usage of clinical laboratories and improving patient care. Copyright 2001 Wiley-Liss, Inc.

  9. A Focused Ethnographic Study of Alberta Cattle Veterinarians’ Decision Making about Diagnostic Laboratory Submissions and Perceptions of Surveillance Programs

    PubMed Central

    Sawford, Kate; Vollman, Ardene Robinson; Stephen, Craig

    2013-01-01

    The animal and public health communities need to address the challenge posed by zoonotic emerging infectious diseases. To minimize the impacts of future events, animal disease surveillance will need to enable prompt event detection and response. Diagnostic laboratory-based surveillance systems targeting domestic animals depend in large part on private veterinarians to submit samples from cases to a laboratory. In contexts where pre-diagnostic laboratory surveillance systems have been implemented, this group of veterinarians is often asked to input data. This scenario holds true in Alberta where private cattle veterinarians have been asked to participate in the Alberta Veterinary Surveillance Network-Veterinary Practice Surveillance, a platform to which pre-diagnostic disease and non-disease case data are submitted. Consequently, understanding the factors that influence these veterinarians to submit cases to a laboratory and the complex of factors that affect their participation in surveillance programs is foundational to interpreting disease patterns reported by laboratories and engaging veterinarians in surveillance. A focused ethnographic study was conducted with ten cattle veterinarians in Alberta. Individual in-depth interviews with participants were recorded and transcribed to enable thematic analysis. Laboratory submissions were biased toward outbreaks of unknown cause, cases with unusual mortality rates, and issues with potential herd-level implications. Decreasing cattle value and government support for laboratory testing have contributed to fewer submissions over time. Participants were willing participants in surveillance, though government support and collaboration were necessary. Changes in the beef industry and veterinary profession, as well as cattle producers themselves, present both challenges and opportunities in surveillance. PMID:23741397

  10. Update on diagnostics for Phytophthora ramorum

    Treesearch

    Philip Berger

    2006-01-01

    Diagnostics used by the U.S. Department of Agriculture (USDA), to determine absence or presence of Phytophthora ramorum in plant samples, are based on a combination of tests and depend on collaboration with external laboratories. The system currently in place attempts to maximize limited resources and at the same time provide the most scientifically...

  11. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics.

    PubMed

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J; Sobrinho Simoes, Manuel

    2017-07-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF , NRAS , HRAS , KRAS , PAX8/PPARG , RET/PTC ) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation.

  12. European Thyroid Association Guidelines regarding Thyroid Nodule Molecular Fine-Needle Aspiration Cytology Diagnostics

    PubMed Central

    Paschke, Ralf; Cantara, Silvia; Crescenzi, Anna; Jarzab, Barbara; Musholt, Thomas J.; Sobrinho Simoes, Manuel

    2017-01-01

    Molecular fine-needle aspiration (FNA) cytology diagnostics has the potential to address the inherent limitation of FNA cytology which is an indeterminate (atypia of undetermined significance/follicular lesion of undetermined significance follicular neoplasm) cytology. Because of the emerging role of molecular FNA cytology diagnostics, the European Thyroid Association convened a panel of international experts to review methodological aspects, indications, results, and limitations of molecular FNA cytology diagnostics. The panel reviewed the evidence for the diagnostic value of mutation panel assessment (including at least BRAF, NRAS, HRAS, KRAS, PAX8/PPARG, RET/PTC) of targeted next generation sequencing and of a microarray gene expression classifier (GEC) test in the diagnostic assessment of an indeterminate cytology thyroid nodule. Moreover, possible surgical consequences of molecular FNA diagnostic results of thyroid nodules and the evidence that analysis of a molecular FNA diagnostic panel of somatic mutations or a microarray GEC test can alter the follow-up were reviewed. Molecular tests may help clinicians to drive patient care and the surgical decision if the analysis is performed in specialized laboratories. These molecular tests require standardization of performance characteristics and appropriate calibration as well as analytic validation before clinical interpretation. PMID:28785538

  13. Laboratory evaluation of suspected motor neuron disease: A survey of physicians.

    PubMed

    Sanderson, Alan B; Novak, John C; Nash, Steven M; Kolb, Stephen J; Kissel, John T

    2015-07-01

    The clinical diagnosis of amyotrophic lateral sclerosis (ALS) relies on exclusion of mimic syndromes, but there are no specific guidelines regarding the extent of laboratory testing required. A survey was sent to 274 physicians listed in the Neuromuscular Section of the American Academy of Neurology. The survey asked how often they order 21 different laboratory tests in patients suspected of having ALS. Ninety-nine responses were received (36% response rate). Greater than 75% ordered serum creatine kinase, chemistry panel, and thyroid functions often or always. Fewer than 25% tested for serum complement, hexosaminidase A, spinal muscular atrophy, Kennedy disease, heavy metals, or human T-cell lymphotrophic virus often or always. Twelve other tests had intermediate responses. There is a lack of consensus among respondents regarding the laboratory evaluation of suspected ALS. Prospective studies are needed to define the diagnostic yield and cost-effectiveness of laboratory testing in this population. © 2015 Wiley Periodicals, Inc.

  14. 76 FR 38342 - Medicare Program; Clinical Laboratory Fee Schedule: Signature on Requisition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-30

    ... cases, the physician may keep abreast of the patient's condition by calling the nursing staff. If a patient's condition indicates that a clinical diagnostic laboratory test is required, the nursing staff... signature on the requisition. Another example that occurs in many settings, including nursing homes, all...

  15. Modeling Canadian Quality Control Test Program for Steroid Hormone Receptors in Breast Cancer: Diagnostic Accuracy Study.

    PubMed

    Pérez, Teresa; Makrestsov, Nikita; Garatt, John; Torlakovic, Emina; Gilks, C Blake; Mallett, Susan

    The Canadian Immunohistochemistry Quality Control program monitors clinical laboratory performance for estrogen receptor and progesterone receptor tests used in breast cancer treatment management in Canada. Current methods assess sensitivity and specificity at each time point, compared with a reference standard. We investigate alternative performance analysis methods to enhance the quality assessment. We used 3 methods of analysis: meta-analysis of sensitivity and specificity of each laboratory across all time points; sensitivity and specificity at each time point for each laboratory; and fitting models for repeated measurements to examine differences between laboratories adjusted by test and time point. Results show 88 laboratories participated in quality control at up to 13 time points using typically 37 to 54 histology samples. In meta-analysis across all time points no laboratories have sensitivity or specificity below 80%. Current methods, presenting sensitivity and specificity separately for each run, result in wide 95% confidence intervals, typically spanning 15% to 30%. Models of a single diagnostic outcome demonstrated that 82% to 100% of laboratories had no difference to reference standard for estrogen receptor and 75% to 100% for progesterone receptor, with the exception of 1 progesterone receptor run. Laboratories with significant differences to reference standard identified with Generalized Estimating Equation modeling also have reduced performance by meta-analysis across all time points. The Canadian Immunohistochemistry Quality Control program has a good design, and with this modeling approach has sufficient precision to measure performance at each time point and allow laboratories with a significantly lower performance to be targeted for advice.

  16. Testing practices and volume of non-Lyme tickborne diseases in the United States.

    PubMed

    Connally, Neeta P; Hinckley, Alison F; Feldman, Katherine A; Kemperman, Melissa; Neitzel, David; Wee, Siok-Bi; White, Jennifer L; Mead, Paul S; Meek, James I

    2016-02-01

    Large commercial laboratories in the United States were surveyed regarding the number of specimens tested for eight tickborne diseases in 2008. Seven large commercial laboratories reported testing a total of 2,927,881 specimens nationally (including Lyme disease). Of these, 495,585 specimens (17%) were tested for tickborne diseases other than Lyme disease. In addition to large commercial laboratories, another 1051 smaller commercial, hospital, and government laboratories in four states (CT, MD, MN, and NY) were surveyed regarding tickborne disease testing frequency, practices, and results. Ninety-two of these reported testing a total of 10,091 specimens for four tickborne diseases other than Lyme disease. We estimate the cost of laboratory diagnostic testing for non-Lyme disease tickborne diseases in 2008 to be $9.6 million. These data provide a baseline to evaluate trends in tickborne disease test utilization and insight into the burden of these diseases. Copyright © 2015 Elsevier GmbH. All rights reserved.

  17. Development and assessment of molecular diagnostic tests for 15 enteropathogens causing childhood diarrhoea: a multicentre study.

    PubMed

    Liu, Jie; Kabir, Furqan; Manneh, Jainaba; Lertsethtakarn, Paphavee; Begum, Sharmin; Gratz, Jean; Becker, Steve M; Operario, Darwin J; Taniuchi, Mami; Janaki, Lalitha; Platts-Mills, James A; Haverstick, Doris M; Kabir, Mamun; Sobuz, Shihab U; Nakjarung, Kaewkanya; Sakpaisal, Pimmada; Silapong, Sasikorn; Bodhidatta, Ladaporn; Qureshi, Shahida; Kalam, Adil; Saidi, Queen; Swai, Ndealilia; Mujaga, Buliga; Maro, Athanasia; Kwambana, Brenda; Dione, Michel; Antonio, Martin; Kibiki, Gibson; Mason, Carl J; Haque, Rashidul; Iqbal, Najeeha; Zaidi, Anita K M; Houpt, Eric R

    2014-08-01

    Childhood diarrhoea can be caused by many pathogens that are difficult to assay in the laboratory. Molecular diagnostic techniques provide a uniform method to detect and quantify candidate enteropathogens. We aimed to develop and assess molecular tests for identification of enteropathogens and their association with disease. We developed and assessed molecular diagnostic tests for 15 enteropathogens across three platforms-PCR-Luminex, multiplex real-time PCR, and TaqMan array card-at five laboratories worldwide. We judged the analytical and clinical performance of these molecular techniques against comparator methods (bacterial culture, ELISA, and PCR) using 867 diarrhoeal and 619 non-diarrhoeal stool specimens. We also measured molecular quantities of pathogens to predict the association with diarrhoea, by univariate logistic regression analysis. The molecular tests showed very good analytical and clinical performance at all five laboratories. Comparator methods had limited sensitivity compared with the molecular techniques (20-85% depending on the target) but good specificity (median 97·3%, IQR 96·5-98·9; mean 95·2%, SD 9·1). Positive samples by comparator methods usually had higher molecular quantities of pathogens than did negative samples, across almost all platforms and for most pathogens (p<0·05). The odds ratio for diarrhoea at a given quantity (measured by quantification cycle, Cq) showed that for most pathogens associated with diarrhoea-including Campylobacter jejuni and Campylobacter coli, Cryptosporidium spp, enteropathogenic Escherichia coli, heat-stable enterotoxigenic E coli, rotavirus, Shigella spp and enteroinvasive E coli, and Vibrio cholerae-the strength of association with diarrhoea increased at higher pathogen loads. For example, Shigella spp at a Cq range of 15-20 had an odds ratio of 8·0 (p<0·0001), but at a Cq range of 25-30 the odds ratio fell to 1·7 (p=0·043). Molecular diagnostic tests can be implemented successfully and with fidelity across laboratories around the world. In the case of diarrhoea, these techniques can detect pathogens with high sensitivity and ascribe diarrhoeal associations based on quantification, including in mixed infections, providing rich and unprecedented measurements of infectious causes. Bill & Melinda Gates Foundation Next Generation Molecular Diagnostics Project. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Impact of providing fee data on laboratory test ordering: a controlled clinical trial.

    PubMed

    Feldman, Leonard S; Shihab, Hasan M; Thiemann, David; Yeh, Hsin-Chieh; Ardolino, Margaret; Mandell, Steven; Brotman, Daniel J

    2013-05-27

    Inpatient care providers often order laboratory tests without any appreciation for the costs of the tests. To determine whether we could decrease the number of laboratory tests ordered by presenting providers with test fees at the time of order entry in a tertiary care hospital, without adding extra steps to the ordering process. Controlled clinical trial. Tertiary care hospital. All providers, including physicians and nonphysicians, who ordered laboratory tests through the computerized provider order entry system at The Johns Hopkins Hospital. We randomly assigned 61 diagnostic laboratory tests to an "active" arm (fee displayed) or to a control arm (fee not displayed). During a 6-month baseline period (November 10, 2008, through May 9, 2009), we did not display any fee data. During a 6-month intervention period 1 year later (November 10, 2009, through May 9, 2010), we displayed fees, based on the Medicare allowable fee, for active tests only. We examined changes in the total number of orders placed, the frequency of ordered tests (per patient-day), and total charges associated with the orders according to the time period (baseline vs intervention period) and by study group (active test vs control). For the active arm tests, rates of test ordering were reduced from 3.72 tests per patient-day in the baseline period to 3.40 tests per patient-day in the intervention period (8.59% decrease; 95% CI, -8.99% to -8.19%). For control arm tests, ordering increased from 1.15 to 1.22 tests per patient-day from the baseline period to the intervention period (5.64% increase; 95% CI, 4.90% to 6.39%) (P < .001 for difference over time between active and control tests). Presenting fee data to providers at the time of order entry resulted in a modest decrease in test ordering. Adoption of this intervention may reduce the number of inappropriately ordered diagnostic tests.

  19. Laboratory Innovation Towards Quality Program Sustainability.

    PubMed

    Abimiku, Alash'le; Timperi, Ralph; Blattner, William

    2016-08-01

    Laboratory innovation significantly affects program sustainability of HIV programs in low and middle income countries (LMICs) far beyond its immediate sphere of impact. Innovation in rapid development of diagnostic technologies, improved quality management systems, strengthened laboratory management, affordable external quality assurance and accreditation schemes, and building local capacity have reduced costs, brought quality improvement to point-of-care testing, increased access to testing services, reduced treatment and prevention costs and opened the door to the real possibility of ending the AIDS epidemic. However, for effectively implemented laboratory innovation to contribute to HIV quality program sustainability, it must be implemented within the overall context of the national strategic plan and HIV treatment programs. The high quality of HIV rapid diagnostic test was a breakthrough that made it possible for more persons to learn their HIV status, receive counseling, and if infected to receive treatment. Likewise, the use of dried blood spots made the shipment of samples easier for the assessment of different variables of HIV infection-molecular diagnosis, CD4+ cell counts, HIV antibodies, drug resistance surveillance, and even antiretroviral drug level measurements. Such advancement is critical for to reaching the UNAIDS target of 90-90-90 and for bringing the AIDS epidemic to an end, especially in LMICs.

  20. Laboratory hemostasis: milestones in Clinical Chemistry and Laboratory Medicine.

    PubMed

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2013-01-01

    Hemostasis is a delicate, dynamic and intricate system, in which pro- and anti-coagulant forces cooperate for either maintaining blood fluidity under normal conditions, or else will prompt blood clot generation to limit the bleeding when the integrity of blood vessels is jeopardized. Excessive prevalence of anticoagulant forces leads to hemorrhage, whereas excessive activation of procoagulant forces triggers excessive coagulation and thrombosis. The hemostasis laboratory performs a variety of first, second and third line tests, and plays a pivotal role in diagnostic and monitoring of most hemostasis disturbances. Since the leading targets of Clinical Chemistry and Laboratory Medicine include promotion of progress in fundamental and applied research, along with publication of guidelines and recommendations in laboratory diagnostics, this journal is an ideal source of information on current developments in the laboratory technology of hemostasis, and this article is aimed to celebrate some of the most important and popular articles ever published by the journal in the filed of laboratory hemostasis.

  1. Standardizing in vitro diagnostics tasks in clinical trials: a call for action.

    PubMed

    Lippi, Giuseppe; Simundic, Ana-Maria; Rodriguez-Manas, Leocadio; Bossuyt, Patrick; Banfi, Giuseppe

    2016-05-01

    Translational research is defined as the process of applying ideas, insights and discoveries generated through basic scientific inquiry to treatment or prevention of human diseases. Although precise information is lacking, several lines of evidence attest that up to 95% early-phase studies may not translate into tangible outcomes for improving clinical management. Major theoretical hurdles exist in the translational process, but is it also undeniable that many studies may have failed for practical reasons, such as the use of inappropriate diagnostic testing for evaluating efficacy, effectiveness or safety of a given medical intervention, or poor quality in laboratory testing. This can generate biased test results and result in misconceptions during data interpretation, eventually leading to no clinical benefit, possible harm, and a waste of valuable resources. From a genuine economic perspective, it can be estimated that over 10 million euros of funding may be lost each year in clinical trials in the European Union due to preanalytical and analytical problems. These are mostly attributions to the heterogeneity of current guidelines and recommendations for the testing process, to the poor evidence base for basic pre-analytical, analytical and post-analytical requirements in clinical trials, and to the failure to thoughtfully integrate the perspectives of clinicians, patients, nurses and diagnostic companies in laboratory best practices. The most rational means for filling the gap between what we know and what we practice in clinical trials cannot discount the development of multidisciplinary teams including research scientists, clinicians, nurses, patients associations and representative of in vitro diagnostic (IVD) companies, who should actively interplay and collaborate with laboratory professionals to adapt and disseminate evidence-based recommendations about biospecimen collection and management into the research settings, from preclinical to phase III studies.

  2. An analysis of reference laboratory (send out) testing: an 8-year experience in a large academic medical center.

    PubMed

    MacMillan, Donna; Lewandrowski, Elizabeth; Lewandrowski, Kent

    2004-01-01

    Utilization of outside reference laboratories for selected laboratory testing is common in the United States. However, relatively little data exist in the literature describing the scope and impact of these services. In this study, we reviewed use of reference laboratory testing at the Massachusetts General Hospital, a large urban academic medical center in Boston, Massachusetts. A retrospective review of hospital and laboratory administrative records over an 8-year period from fiscal years (FY) 1995-2002. Over the 8 years studied, reference laboratory expenses increased 4.2-fold and totaled 12.4% of the total laboratory budget in FY 2002. Total reference laboratory test volume increased 4-fold to 68,328 tests in FY 2002 but represented only 1.06% of the total test volume in the hospital. The menu of reference laboratory tests comprised 946 tests (65.7% of the hospital test menu) compared to 494 (34.3%) of tests performed in house. The average unit cost of reference laboratory tests was essentially unchanged but was approximately 13 times greater than the average unit cost in the hospital laboratory. Much of the growth in reference laboratory cost can be attributed to the addition of new molecular, genetic, and microbiological assays. Four of the top 10 tests with the highest total cost in 2002 were molecular diagnostic tests that were recently added to the test menu. Reference laboratory testing comprises a major component of hospital clinical laboratory services. Although send out tests represent a small percentage of the total test volume, these services account for the majority of the hospital laboratory test menu and a disproportionate percentage of laboratory costs.

  3. Validation of a Rapid Rabies Diagnostic Tool for Field Surveillance in Developing Countries

    PubMed Central

    Léchenne, Monique; Naïssengar, Kemdongarti; Lepelletier, Anthony; Alfaroukh, Idriss Oumar; Bourhy, Hervé; Zinsstag, Jakob; Dacheux, Laurent

    2016-01-01

    Background One root cause of the neglect of rabies is the lack of adequate diagnostic tests in the context of low income countries. A rapid, performance friendly and low cost method to detect rabies virus (RABV) in brain samples will contribute positively to surveillance and consequently to accurate data reporting, which is presently missing in the majority of rabies endemic countries. Methodology/Principal findings We evaluated a rapid immunodiagnostic test (RIDT) in comparison with the standard fluorescent antibody test (FAT) and confirmed the detection of the viral RNA by real time reverse transcription polymerase chain reaction (RT-qPCR). Our analysis is a multicentre approach to validate the performance of the RIDT in both a field laboratory (N’Djamena, Chad) and an international reference laboratory (Institut Pasteur, Paris, France). In the field laboratory, 48 samples from dogs were tested and in the reference laboratory setting, a total of 73 samples was tested, representing a wide diversity of RABV in terms of animal species tested (13 different species), geographical origin of isolates with special emphasis on Africa, and different phylogenetic clades. Under reference laboratory conditions, specificity was 93.3% and sensitivity was 95.3% compared to the gold standard FAT test. Under field laboratory conditions, the RIDT yielded a higher reliability than the FAT test particularly on fresh and decomposed samples. Viral RNA was later extracted directly from the test filter paper and further used successfully for sequencing and genotyping. Conclusion/Significance The RIDT shows excellent performance qualities both in regard to user friendliness and reliability of the result. In addition, the test cassettes can be used as a vehicle to ship viral RNA to reference laboratories for further laboratory confirmation of the diagnosis and for epidemiological investigations using nucleotide sequencing. The potential for satisfactory use in remote locations is therefore very high to improve the global knowledge of rabies epidemiology. However, we suggest some changes to the protocol, as well as careful further validation, before promotion and wider use. PMID:27706156

  4. 21 CFR 660.43 - Potency test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Potency test. 660.43 Section 660.43 Food and Drugs... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.43 Potency test... antibody in the appropriate sera of the reference panel by all test methods recommended by the manufacturer...

  5. 21 CFR 660.33 - Testing of source material.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...

  6. 21 CFR 660.33 - Testing of source material.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...

  7. 21 CFR 660.33 - Testing of source material.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...

  8. 21 CFR 660.33 - Testing of source material.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...

  9. 21 CFR 660.33 - Testing of source material.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660... incorporated into the Reagent Red Blood Cell product shall be individually tested, with no fewer than two donor... tests for each factor. The Reagent Red Blood Cell product may be tested with a single donor source of...

  10. Feline Genetics: Clinical Applications and Genetic Testing

    PubMed Central

    Lyons, Leslie A.

    2010-01-01

    DNA testing for domestic cat diseases and appearance traits is a rapidly growing asset for veterinary medicine. Approximately thirty-three genes contain fifty mutations that cause feline health problems or alterations in the cat’s appearance. A variety of commercial laboratories can now perform cat genetic diagnostics, allowing both the veterinary clinician and the private owner to obtain DNA test results. DNA is easily obtained from a cat via a buccal swab using a standard cotton bud or cytological brush, allowing DNA samples to be easily sent to any laboratory in the world. The DNA test results identify carriers of the traits, predict the incidence of traits from breeding programs, and influence medical prognoses and treatments. An overall goal of identifying these genetic mutations is the correction of the defect via gene therapies and designer drug therapies. Thus, genetic testing is an effective preventative medicine and a potential ultimate cure. However, genetic diagnostic tests may still be novel for many veterinary practitioners and their application in the clinical setting needs to have the same scrutiny as any other diagnostic procedure. This article will review the genetic tests for the domestic cat, potential sources of error for genetic testing, and the pros and cons of DNA results in veterinary medicine. Highlighted are genetic tests specific to the individual cat, which are a part of the cat’s internal genome. PMID:21147473

  11. Feline genetics: clinical applications and genetic testing.

    PubMed

    Lyons, Leslie A

    2010-11-01

    DNA testing for domestic cat diseases and appearance traits is a rapidly growing asset for veterinary medicine. Approximately 33 genes contain 50 mutations that cause feline health problems or alterations in the cat's appearance. A variety of commercial laboratories can now perform cat genetic diagnostics, allowing both the veterinary clinician and the private owner to obtain DNA test results. DNA is easily obtained from a cat via a buccal swab with a standard cotton bud or cytological brush, allowing DNA samples to be easily sent to any laboratory in the world. The DNA test results identify carriers of the traits, predict the incidence of traits from breeding programs, and influence medical prognoses and treatments. An overall goal of identifying these genetic mutations is the correction of the defect via gene therapies and designer drug therapies. Thus, genetic testing is an effective preventative medicine and a potential ultimate cure. However, genetic diagnostic tests may still be novel for many veterinary practitioners and their application in the clinical setting needs to have the same scrutiny as any other diagnostic procedure. This article will review the genetic tests for the domestic cat, potential sources of error for genetic testing, and the pros and cons of DNA results in veterinary medicine. Highlighted are genetic tests specific to the individual cat, which are a part of the cat's internal genome. Copyright © 2010 Elsevier Inc. All rights reserved.

  12. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 7 2011-04-01 2010-04-01 true Specificity tests and avidity tests. 660.26 Section 660.26 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.26 Specificity tests and avidity test...

  13. Laboratory automation: trajectory, technology, and tactics.

    PubMed

    Markin, R S; Whalen, S A

    2000-05-01

    Laboratory automation is in its infancy, following a path parallel to the development of laboratory information systems in the late 1970s and early 1980s. Changes on the horizon in healthcare and clinical laboratory service that affect the delivery of laboratory results include the increasing age of the population in North America, the implementation of the Balanced Budget Act (1997), and the creation of disease management companies. Major technology drivers include outcomes optimization and phenotypically targeted drugs. Constant cost pressures in the clinical laboratory have forced diagnostic manufacturers into less than optimal profitability states. Laboratory automation can be a tool for the improvement of laboratory services and may decrease costs. The key to improvement of laboratory services is implementation of the correct automation technology. The design of this technology should be driven by required functionality. Automation design issues should be centered on the understanding of the laboratory and its relationship to healthcare delivery and the business and operational processes in the clinical laboratory. Automation design philosophy has evolved from a hardware-based approach to a software-based approach. Process control software to support repeat testing, reflex testing, and transportation management, and overall computer-integrated manufacturing approaches to laboratory automation implementation are rapidly expanding areas. It is clear that hardware and software are functionally interdependent and that the interface between the laboratory automation system and the laboratory information system is a key component. The cost-effectiveness of automation solutions suggested by vendors, however, has been difficult to evaluate because the number of automation installations are few and the precision with which operational data have been collected to determine payback is suboptimal. The trend in automation has moved from total laboratory automation to a modular approach, from a hardware-driven system to process control, from a one-of-a-kind novelty toward a standardized product, and from an in vitro diagnostics novelty to a marketing tool. Multiple vendors are present in the marketplace, many of whom are in vitro diagnostics manufacturers providing an automation solution coupled with their instruments, whereas others are focused automation companies. Automation technology continues to advance, acceptance continues to climb, and payback and cost justification methods are developing.

  14. Identifying an outbreak of a novel swine disease using test requests for porcine reproductive and respiratory syndrome as a syndromic surveillance tool

    PubMed Central

    2012-01-01

    Background Animal disease monitoring and surveillance are crucial for ensuring the health of animals, humans and the environment. Many studies have investigated the utility of monitoring syndromes associated with data from veterinary laboratory submissions, but no research has focused on how negative test results from a veterinary diagnostic laboratory data can be used to improve our knowledge of disease outbreaks. For example, if a diagnostic laboratory was seeing a disproportionate number of negative test results for a known disease could this information be an indication of a novel disease outbreak? The objective of this study was to determine the association between the porcine circovirus associated disease (PCVAD) outbreak in Ontario 2004–2006 and the results of porcine reproductive and respiratory syndrome virus (PPRSV) enzyme-linked immunosorbent assay (ELISA) and the results of PRRSV polymerase chain reaction (PCR) diagnostic tests requested by veterinarians. Results Retrospective data were collected from the Animal Health Laboratory (AHL) at the University of Guelph, Guelph, Ontario Canada and were comprised of weekly counts of PRRSV ELISA and PRRSV PCR diagnostic tests requested by swine practitioners from 2000–2007. The results of the PRRSV ELISA and PRRSV PCRs were analysed separately in two models using logistic regression with the dependent variables being: the weekly probability of PRRSV ELISA positivity, and the weekly probability of PRRSV PCR positivity, respectively. The weekly probability of PRRSV PCR positivity decreased during the PVCAD outbreak (OR=0.66, P=0.01). The weekly probability of PRRSV ELISA positivity was not associated with the PCVAD outbreak. Conclusions The results of this study showed that during the PCVAD outbreak in Ontario from December 2004-May 2006, the probability of a positive PRRSV PCR at the AHL decreased. We conclude that when a decrease in test positivity occurs for a known disease, it may suggest that a new disease agent is emerging in the population. Hence, monitoring the test results of commonly used first-order tests for a known disease (e.g. PRRSV) has the potential to be a unique form of syndromic data for the timely identification of novel disease outbreaks in swine populations. PMID:23072647

  15. Incidence and Trends of Infections with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance - Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2013-2016.

    PubMed

    Marder, Ellyn P; Cieslak, Paul R; Cronquist, Alicia B; Dunn, John; Lathrop, Sarah; Rabatsky-Ehr, Therese; Ryan, Patricia; Smith, Kirk; Tobin-D'Angelo, Melissa; Vugia, Duc J; Zansky, Shelley; Holt, Kristin G; Wolpert, Beverly J; Lynch, Michael; Tauxe, Robert; Geissler, Aimee L

    2017-04-21

    Foodborne diseases represent a substantial public health concern in the United States. CDC's Foodborne Diseases Active Surveillance Network (FoodNet) monitors cases reported from 10 U.S. sites* of laboratory-diagnosed infections caused by nine enteric pathogens commonly transmitted through food. This report describes preliminary surveillance data for 2016 on the nine pathogens and changes in incidences compared with 2013-2015. In 2016, FoodNet identified 24,029 infections, 5,512 hospitalizations, and 98 deaths caused by these pathogens. The use of culture-independent diagnostic tests (CIDTs) by clinical laboratories to detect enteric pathogens has been steadily increasing since FoodNet began surveying clinical laboratories in 2010 (1). CIDTs complicate the interpretation of FoodNet surveillance data because pathogen detection could be affected by changes in health care provider behaviors or laboratory testing practices (2). Health care providers might be more likely to order CIDTs because these tests are quicker and easier to use than traditional culture methods, a circumstance that could increase pathogen detection (3). Similarly, pathogen detection could also be increasing as clinical laboratories adopt DNA-based syndromic panels, which include pathogens not often included in routine stool culture (4,5). In addition, CIDTs do not yield isolates, which public health officials rely on to distinguish pathogen subtypes, determine antimicrobial resistance, monitor trends, and detect outbreaks. To obtain isolates for infections identified by CIDTs, laboratories must perform reflex culture † ; if clinical laboratories do not, the burden of culturing falls to state public health laboratories, which might not be able to absorb that burden as the adoption of these tests increases (2). Strategies are needed to preserve access to bacterial isolates for further characterization and to determine the effect of changing trends in testing practices on surveillance.

  16. Laboratory diagnosis of ophthalmic sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinreb, R.N.; Tessler, H.

    Because the eye is involved in about 25% of patients with active sarcoid, the ophthalmologist is often the first physician to see these patients. Although clinical findings may suggest sarcoid, laboratory tests (e.g., x-ray, skin tests, blood chemistries, etc.) may be normal or inconclusive. Thus, it is important that the ophthalmologist be aware of the availability and limitations of the various biochemical, immunological, radiological, and histopathological tests that contribute to the early diagnosis of sarcoidosis. The authors review diagnostic procedures and present a flowchart detailing indications for each.

  17. Diagnostic Strategy Used To Establish Etiologies of Encephalitis in a Prospective Cohort of Patients in England▿

    PubMed Central

    Ambrose, H. E.; Granerod, J.; Clewley, J. P.; Davies, N. W. S.; Keir, G.; Cunningham, R.; Zuckerman, M.; Mutton, K. J.; Ward, K. N.; Ijaz, S.; Crowcroft, N. S.; Brown, D. W. G.

    2011-01-01

    The laboratory diagnostic strategy used to determine the etiology of encephalitis in 203 patients is reported. An etiological diagnosis was made by first-line laboratory testing for 111 (55%) patients. Subsequent testing, based on individual case reviews, resulted in 17 (8%) further diagnoses, of which 12 (71%) were immune-mediated and 5 (29%) were due to infection. Seventy-five cases were of unknown etiology. Sixteen (8%) of 203 samples were found to be associated with either N-methyl-d-aspartate receptor or voltage-gated potassium channel complex antibodies. The most common viral causes identified were herpes simplex virus (HSV) (19%) and varicella-zoster virus (5%), while the most important bacterial cause was Mycobacterium tuberculosis (5%). The diagnostic value of testing cerebrospinal fluid (CSF) for antibody was assessed using 139 samples from 99 patients, and antibody was detected in 46 samples from 37 patients. Samples collected at 14 to 28 days were more likely to be positive than samples taken 0 to 6 days postadmission. Three PCR-negative HSV cases were diagnosed by the presence of virus-specific antibody in the central nervous system (CNS). It was not possible to make an etiological diagnosis for one-third of the cases; these were therefore considered to be due to unknown causes. Delayed sampling did not contribute to these cases. Twenty percent of the patients with infections with an unknown etiology showed evidence of localized immune activation within the CNS, but no novel viral DNA or RNA sequences were found. We conclude that a good standard of clinical investigation and thorough first-line laboratory testing allows the diagnosis of most cases of infectious encephalitis; testing for CSF antibodies allows further cases to be diagnosed. It is important that testing for immune-mediated causes also be included in a diagnostic algorithm. PMID:21865429

  18. Malaria Diagnostics in Clinical Trials

    PubMed Central

    Murphy, Sean C.; Shott, Joseph P.; Parikh, Sunil; Etter, Paige; Prescott, William R.; Stewart, V. Ann

    2013-01-01

    Malaria diagnostics are widely used in epidemiologic studies to investigate natural history of disease and in drug and vaccine clinical trials to exclude participants or evaluate efficacy. The Malaria Laboratory Network (MLN), managed by the Office of HIV/AIDS Network Coordination, is an international working group with mutual interests in malaria disease and diagnosis and in human immunodeficiency virus/acquired immunodeficiency syndrome clinical trials. The MLN considered and studied the wide array of available malaria diagnostic tests for their suitability for screening trial participants and/or obtaining study endpoints for malaria clinical trials, including studies of HIV/malaria co-infection and other malaria natural history studies. The MLN provides recommendations on microscopy, rapid diagnostic tests, serologic tests, and molecular assays to guide selection of the most appropriate test(s) for specific research objectives. In addition, this report provides recommendations regarding quality management to ensure reproducibility across sites in clinical trials. Performance evaluation, quality control, and external quality assessment are critical processes that must be implemented in all clinical trials using malaria tests. PMID:24062484

  19. Performance of the High-Energy Single-Event Effects Test Facility (SEETF) at Michigan State University's National Superconducting Cyclotron Laboratory (NSCL)

    NASA Technical Reports Server (NTRS)

    Ladbury, R.; Reed, R. A.; Marshall, P. W.; LaBel, K. A.; Anantaraman, R.; Fox, R.; Sanderson, D. P.; Stolz, A.; Yurkon, J.; Zeller, A. F.; hide

    2004-01-01

    The performance of Michigan State University's Single-Event Effects Test Facility (SEETF) during its inaugural runs is evaluated. Beam profiles and other diagnostics are presented, and prospects for future development and testing are discussed.

  20. A data-driven algorithm integrating clinical and laboratory features for the diagnosis and prognosis of necrotizing enterocolitis.

    PubMed

    Ji, Jun; Ling, Xuefeng B; Zhao, Yingzhen; Hu, Zhongkai; Zheng, Xiaolin; Xu, Zhening; Wen, Qiaojun; Kastenberg, Zachary J; Li, Ping; Abdullah, Fizan; Brandt, Mary L; Ehrenkranz, Richard A; Harris, Mary Catherine; Lee, Timothy C; Simpson, B Joyce; Bowers, Corinna; Moss, R Lawrence; Sylvester, Karl G

    2014-01-01

    Necrotizing enterocolitis (NEC) is a major source of neonatal morbidity and mortality. Since there is no specific diagnostic test or risk of progression model available for NEC, the diagnosis and outcome prediction of NEC is made on clinical grounds. The objective in this study was to develop and validate new NEC scoring systems for automated staging and prognostic forecasting. A six-center consortium of university based pediatric teaching hospitals prospectively collected data on infants under suspicion of having NEC over a 7-year period. A database comprised of 520 infants was utilized to develop the NEC diagnostic and prognostic models by dividing the entire dataset into training and testing cohorts of demographically matched subjects. Developed on the training cohort and validated on the blind testing cohort, our multivariate analyses led to NEC scoring metrics integrating clinical data. Machine learning using clinical and laboratory results at the time of clinical presentation led to two nec models: (1) an automated diagnostic classification scheme; (2) a dynamic prognostic method for risk-stratifying patients into low, intermediate and high NEC scores to determine the risk for disease progression. We submit that dynamic risk stratification of infants with NEC will assist clinicians in determining the need for additional diagnostic testing and guide potential therapies in a dynamic manner. http://translationalmedicine.stanford.edu/cgi-bin/NEC/index.pl and smartphone application upon request.

  1. Combination of culture, antigen and toxin detection, and cytotoxin neutralization assay for optimal Clostridium difficile diagnostic testing

    PubMed Central

    Alfa, Michelle J; Sepehri, Shadi

    2013-01-01

    BACKGROUND: There has been a growing interest in developing an appropriate laboratory diagnostic algorithm for Clostridium difficile, mainly as a result of increases in both the number and severity of cases of C difficile infection in the past decade. A C difficile diagnostic algorithm is necessary because diagnostic kits, mostly for the detection of toxins A and B or glutamate dehydrogenase (GDH) antigen, are not sufficient as stand-alone assays for optimal diagnosis of C difficile infection. In addition, conventional reference methods for C difficile detection (eg, toxigenic culture and cytotoxin neutralization [CTN] assays) are not routinely practiced in diagnostic laboratory settings. OBJECTIVE: To review the four-step algorithm used at Diagnostic Services of Manitoba sites for the laboratory diagnosis of toxigenic C difficile. RESULT: One year of retrospective C difficile data using the proposed algorithm was reported. Of 5695 stool samples tested, 9.1% (n=517) had toxigenic C difficile. Sixty per cent (310 of 517) of toxigenic C difficile stools were detected following the first two steps of the algorithm. CTN confirmation of GDH-positive, toxin A- and B-negative assays resulted in detection of an additional 37.7% (198 of 517) of toxigenic C difficile. Culture of the third specimen, from patients who had two previous negative specimens, detected an additional 2.32% (12 of 517) of toxigenic C difficile samples. DISCUSSION: Using GDH antigen as the screening and toxin A and B as confirmatory test for C difficile, 85% of specimens were reported negative or positive within 4 h. Without CTN confirmation for GDH antigen and toxin A and B discordant results, 37% (195 of 517) of toxigenic C difficile stools would have been missed. Following the algorithm, culture was needed for only 2.72% of all specimens submitted for C difficile testing. CONCLUSION: The overview of the data illustrated the significance of each stage of this four-step C difficile algorithm and emphasized the value of using CTN assay and culture as parts of an algorithm that ensures accurate diagnosis of toxigenic C difficile. PMID:24421808

  2. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 7 2012-04-01 2012-04-01 false Specificity tests and avidity tests. 660.26 Section 660.26 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.26 Specificity tests and avidity...

  3. 21 CFR 660.26 - Specificity tests and avidity tests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 7 2014-04-01 2014-04-01 false Specificity tests and avidity tests. 660.26 Section 660.26 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.26 Specificity tests and avidity...

  4. National and international veterinary reference laboratories for infectious diseases.

    PubMed

    Edwards, S; Alexander, D

    1998-08-01

    Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.

  5. Next generation diagnostic molecular pathology: critical appraisal of quality assurance in Europe.

    PubMed

    Dubbink, Hendrikus J; Deans, Zandra C; Tops, Bastiaan B J; van Kemenade, Folkert J; Koljenović, S; van Krieken, Han J M; Blokx, Willeke A M; Dinjens, Winand N M; Groenen, Patricia J T A

    2014-06-01

    Tumor evaluation in pathology is more and more based on a combination of traditional histopathology and molecular analysis. Due to the rapid development of new cancer treatments that specifically target aberrant proteins present in tumor cells, treatment decisions are increasingly based on the molecular features of the tumor. Not only the number of patients eligible for targeted precision medicine, but also the number of molecular targets per patient and tumor type is rising. Diagnostic molecular pathology, the discipline that determines the molecular aberrations present in tumors for diagnostic, prognostic or predictive purposes, is faced with true challenges. The laboratories have to meet the need of comprehensive molecular testing using only limited amount of tumor tissue, mostly fixed in formalin and embedded in paraffin (FFPE), in short turnaround time. Choices must be made for analytical methods that provide accurate, reliable and cost-effective results. Validation of the test procedures and results is essential. In addition, participation and good performance in internal (IQA) and external quality assurance (EQA) schemes is mandatory. In this review, we critically evaluate the validation procedure for comprehensive molecular tests as well as the organization of quality assurance and assessment of competence of diagnostic molecular pathology laboratories within Europe. Copyright © 2014 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.

  6. Laboratory Surge Response to Pandemic (H1N1) 2009 Outbreak, New York City Metropolitan Area, USA

    PubMed Central

    Crawford, James M.; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D.; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M.

    2010-01-01

    The North Shore–Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments. PMID:20031036

  7. Laboratory surge response to pandemic (H1N1) 2009 outbreak, New York City metropolitan area, USA.

    PubMed

    Crawford, James M; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M; Ginocchio, Christine C

    2010-01-01

    The North Shore-Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments.

  8. Specialized sperm function tests in varicocele and the future of andrology laboratory.

    PubMed

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele.

  9. Centralization of a regional clinical microbiology service: The Calgary experience

    PubMed Central

    Church, Deirdre L; Hall, Paula

    1999-01-01

    Diagnostic laboratory services in Alberta have been dramatically restructured over the past five years. In 1994, Alberta Health embarked on an aggressive laboratory restructuring that cut back approximately 30% of the overall monies previously paid to the laboratory service sector in Calgary. A unique service delivery model consolidated all institutional and community-based diagnostic testing in a company called Calgary Laboratory Services (CLS) in late 1996. CLS was formed by a public/private partnership between the Calgary Regional Health Care Authority (CRHA) and MDS-Kasper Laboratories. By virtue of its customer service base and scope of testing, CLS provides comprehensive regional laboratory services to the entire populace. Regional microbiology services within CLS have been successfully consolidated over the past three years into a centralized high volume laboratory (HVL). Because the HVL is not located in a hospital, rapid response laboratories (RRLs) are operated at each acute care site. Although the initial principle behind the proposed test menus for the RRLs was that only procedures requiring a clinical turnaround time of more than 2 h stay on-site, many other principles had to be used to develop and implement an efficient and clinically relevant RRL model for microbiology. From these guiding principles, a detailed assessment of the needs of each institution and extensive networking with user groups, the functions of the microbiology RRLs were established and a detailed implementation plan drawn up. The experience at CLS with regards to restructuring a regional microbiology service is described herein. A post-hoc analysis provides the pros and cons of directing and operating a regionalized microbiology service. PMID:22346397

  10. The Daniel K. Inouye College of Pharmacy Scripts: Updates on Clostridium difficile Infection: Advances in Laboratory Testing to Aid Diagnosis and Treatment.

    PubMed

    Lteif, Louis

    2017-02-01

    Clostridium difficile remains a major source of nosocomial infections and associated diarrhea. More recently, community-acquired cases are on the rise creating a concern for a serious public health threat. Appropriate infection control precautions as well as prevention and optimal management may help to avoid detrimental outbreaks. A key step is utilizing laboratory testing for quick and accurate diagnosis of potential cases. This overview article describes Clostridium difficile infection control and prevention methods and updates the most recent management strategies including a focus on the utilization and interpretation of laboratory diagnostic testing and appropriate treatment.

  11. 21 CFR 660.4 - Potency test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Potency test. 660.4 Section 660.4 Food and Drugs... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.4 Potency test. To be satisfactory for release, each filling of Antibody to Hepatitis B Surface Antigen...

  12. Emerging Technologies for the Clinical Microbiology Laboratory

    PubMed Central

    Buchan, Blake W.

    2014-01-01

    SUMMARY In this review we examine the literature related to emerging technologies that will help to reshape the clinical microbiology laboratory. These topics include nucleic acid amplification tests such as isothermal and point-of-care molecular diagnostics, multiplexed panels for syndromic diagnosis, digital PCR, next-generation sequencing, and automation of molecular tests. We also review matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) and electrospray ionization (ESI) mass spectrometry methods and their role in identification of microorganisms. Lastly, we review the shift to liquid-based microbiology and the integration of partial and full laboratory automation that are beginning to impact the clinical microbiology laboratory. PMID:25278575

  13. [Laboratory diagnostics and monitoring of virus circulation in surveillance system for rubella in Belarus].

    PubMed

    Samoĭlovich, E O; Semeĭko, G V; Ermolovich, M A; Svirchevskaia, E Iu

    2010-01-01

    To summarize data on laboratory diagnostics of prenatal and postnatal rubella and molecular monitoring of rubella virus circulation in Belarus obtained during implementation of rubella elimination program. Serum samples from 2314 persons were tested on the presence of IgM to rubella virus and measles virus (in case of negative result on rubella) using respective enzyme immunoassays. Virological testing using RT-PCR as well as genotyping on the basis of E1 gene fragment sequencing were also performed. Two viruses isolated in Belarus were set as reference strains of genotypes 1G and 1h. Implementation of laboratory diagnostics allowed to differentiate cases of rubella from other exanthematous infections, significantly increase the number of laboratory-confirmed cases among all reported cases, and show presence of endemic circulation of rubella virus strains of 3 different genotypes (1G, 1E, and 1h) in Belarus (2004-2006). In 2006, when relatively high incidence of rubella was reported in the country (24.39 per 100,000 population), the risk of congenital rubella syndrome was not less than 9 per 100,000 births. Conducted in October 2005-May 2006 additional rounds of immunization against rubella (>1 million people were vaccinated) decreased incidence to single cases. Obtained data show achievability of indigenous rubella elemination by 2010. Revealed genetic diversity of rubella virus strains allowed to update the International classification of wild rubella viruses.

  14. Diagnosing pulmonary embolisms: the clinician's point of view.

    PubMed

    Carrillo Alcaraz, A; Martínez, A López; Solano, F J Sotos

    Pulmonary thromboembolism is common and potentially severe. To ensure the correct approach to the diagnostic workup of pulmonary thromboembolism, it is essential to know the basic concepts governing the use of the different tests available. The diagnostic approach to pulmonary thromboembolism is an example of the application of the conditional probabilities of Bayes' theorem in daily practice. To interpret the available diagnostic tests correctly, it is necessary to analyze different concepts that are fundamental for decision making. Thus, it is necessary to know what the likelihood ratios, 95% confidence intervals, and decision thresholds mean. Whether to determine the D-dimer concentration or to do CT angiography or other imaging tests depends on their capacity to modify the pretest probability of having the disease to a posttest probability that is higher or lower than the thresholds for action. This review aims to clarify the diagnostic sequence of thromboembolic pulmonary disease, analyzing the main diagnostic tools (clinical examination, laboratory tests, and imaging tests), placing special emphasis on the principles that govern evidence-based medicine. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Health laboratories in the Tanga region of Tanzania: the quality of diagnostic services for malaria and other communicable diseases.

    PubMed

    Ishengoma, D R S; Rwegoshora, R T; Mdira, K Y; Kamugisha, M L; Anga, E O; Bygbjerg, I C; Rønn, A M; Magesa, S M

    2009-07-01

    Although critical for good case management and the monitoring of health interventions, the health-laboratory services in sub-Saharan Africa are grossly compromised by poor infrastructures and a lack of trained personnel, essential reagents and other supplies. The availability and quality of diagnostic services in 37 health laboratories in three districts of the Tanga region of Tanzania have recently been assessed. The results of the survey, which involved interviews with health workers, observations and a documentary review, revealed that malaria accounted for >50% of admissions and out-patient visits. Most (92%) of the laboratories were carrying out malaria diagnosis and 89% were measuring haemoglobin concentrations but only one (3%) was conducting culture and sensitivity tests, and those only on urine and pus samples. Only 14 (17%) of the 84 people found working in the visited laboratories were laboratory technologists with a diploma certificate or higher qualification. Sixteen (43%) of the study laboratories each had five or fewer types of equipment and only seven (19%) had more than 11 types each. Although 11 (30%) of the laboratories reported that they conducted internal quality control, none had standard operating procedures (SOP) on display or evidence of such quality assurance. Although malaria was the main health problem, diagnostic services for malaria and other diseases were inadequate and of poor quality because of the limited human resources, poor equipment and shortage of supplies. If the health services in Tanga are not to be overwhelmed by the progressively increasing burden of HIV/AIDS, malaria, tuberculosis and other emerging and re-emerging diseases, more funding and appropriate policies to improve the availability and quality of the area's diagnostic services will clearly be required.

  16. Superior Diagnostic Performance of Malaria Rapid Diagnostic Tests as compared to Blood Smears in U.S. Clinical Practice

    PubMed Central

    Stauffer, William M.; Cartwright, Charles P.; Olson, Douglas; Juni, Billie Anne; Taylor, Charlotte M; Bowers, Susan H.; Hanson, Kevan L.; Rosenblatt, Jon E.; Boulware, David R.

    2010-01-01

    Background Approximately 4 million U.S. travelers to developing countries are ill enough to seek healthcare with 1,500 malaria cases reported in the U.S. annually. The diagnosis of malaria is frequently delayed due to the time to prepare malaria blood films and lack of technical expertise. An easy, reliable rapid diagnostic test (RDT) with high sensitivity and negative predictive value (NPV), particularly for Plasmodium falciparum, would be clinically useful. The study objective was to determine the diagnostic performance of the FDA-approved NOW® Malaria Test in comparison to traditional thick and thin blood smears for malaria diagnosis. Methods This prospective study tested 852 consecutive blood samples sent for thick and thin smears with blinded, malaria rapid tests at three hospital laboratories during 2003–2006. Polymerase chain reaction (PCR) verified positive tests and discordant results. Results Malaria occurred in 11% (95/852). The rapid test had superior performance than the standard Giemsa thick blood smear (P=.003). The rapid test’s sensitivity for all malaria was 97% (92/95) vs. 85% (81/95) by blood smear, and the RDT had superior NPV of 99.6% vs. 98.2% (P=.001). The P. falciparum performance was excellent with 100% rapid test sensitivity versus only 88% (65/74) by blood smear (P=.003). Conclusions This operational study demonstrates the FDA-approved rapid malaria test is superior to a single set of blood smears performed under routine U.S. clinical laboratory conditions. The most valuable clinical role of the RDT is in the rapid diagnosis or the exclusion of P. falciparum malaria, which is particularly useful in outpatient settings when evaluating febrile travelers. PMID:19686072

  17. Novel molecular diagnostic tools for malaria elimination: a review of options from the point of view of high-throughput and applicability in resource limited settings.

    PubMed

    Britton, Sumudu; Cheng, Qin; McCarthy, James S

    2016-02-16

    As malaria transmission continues to decrease, an increasing number of countries will enter pre-elimination and elimination. To interrupt transmission, changes in control strategies are likely to require more accurate identification of all carriers of Plasmodium parasites, both symptomatic and asymptomatic, using diagnostic tools that are highly sensitive, high throughput and with fast turnaround times preferably performed in local health service settings. Currently available immunochromatographic lateral flow rapid diagnostic tests and field microscopy are unlikely to consistently detect infections at parasite densities less than 100 parasites/µL making them insufficiently sensitive for detecting all carriers. Molecular diagnostic platforms, such as PCR and LAMP, are currently available in reference laboratories, but at a cost both financially and in turnaround time. This review describes the recent progress in developing molecular diagnostic tools in terms of their capacity for high throughput and potential for performance in non-reference laboratories for malaria elimination.

  18. Diagnostic methods for insect sting allergy.

    PubMed

    Hamilton, Robert G

    2004-08-01

    This review overviews advances from mid-2002 to the present in the validation and performance methods used in the diagnosis of Hymenoptera venom-induced immediate-type hypersensitivity. The general diagnostic algorithm for insect sting allergy is initially discussed with an examination of the AAAAI's 2003 revised practice parameter guidelines. Changes as a result of a greater recognition of skin test negative systemic reactors include repeat analysis of all testing and acceptance of serology as a complementary diagnostic test to the skin test. Original data examining concordance of venom-specific IgE results produced by the second-generation Pharmacia CAP System with the Johns Hopkins University radioallergosorbent test are presented. Diagnostic performance of honeybee venom-specific IgE assays used in clinical laboratories in North America is discussed using data from the Diagnostic Allergy Proficiency Survey conducted by the College of American Pathologists. Validity of venom-specific IgE antibody in postmortem blood specimens is demonstrated. The utility of alternative in-vivo (provocation) and in-vitro (basophil-based) diagnostic testing methods is critiqued. This overview supports the following conclusions. Improved practice parameter guidelines include serology and skin test as complementary in supporting a positive clinical history during the diagnostic process. Data are provided which support the analytical performance of commercially available venom-specific IgE antibody serology-based assays. Intentional sting challenge in-vivo provocation, in-vitro basophil flow cytometry (CD63, CD203c) based assays, and in-vitro basophil histamine and sulfidoleukotriene release assays have their utility in the study of difficult diagnostic cases, but their use will remain as supplementary, secondary diagnostic tests.

  19. AST Combustion Workshop: Diagnostics Working Group Report

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Hanson, Ronald K.

    1996-01-01

    A workshop was convened under NASA's Advanced Subsonics Technologies (AST) Program. Many of the principal combustion diagnosticians from industry, academia, and government laboratories were assembled in the Diagnostics/Testing Subsection of this workshop to discuss the requirements and obstacles to the successful implementation of advanced diagnostic techniques to the test environment of the proposed AST combustor. The participants, who represented the major relevant areas of advanced diagnostic methods currently applied to combustion and related fields, first established the anticipated AST combustor flowfield conditions. Critical flow parameters were then examined and prioritized as to their importance to combustor/fuel injector design and manufacture, environmental concerns, and computational interests. Diagnostic techniques were then evaluated in terms of current status, merits and obstacles for each flow parameter. All evaluations are presented in tabular form and recommendations are made on the best-suited diagnostic method to implement for each flow parameter in order of applicability and intrinsic value.

  20. Universal reverse-transcriptase real-time PCR for infectious hematopoietic necrosis virus (IHNV)

    USGS Publications Warehouse

    Purcell, Maureen K.; Thompson, Rachel L.; Garver, Kyle A.; Hawley, Laura M.; Batts, William N.; Sprague, Laura; Sampson, Corie; Winton, James R.

    2013-01-01

    Infectious hematopoietic necrosis virus (IHNV) is an acute pathogen of salmonid fishes in North America, Europe and Asia and is reportable to the World Organization for Animal Health (OIE). Phylogenetic analysis has identified 5 major virus genogroups of IHNV worldwide, designated U, M, L, E and J; multiple subtypes also exist within those genogroups. Here, we report the development and validation of a universal IHNV reverse-transcriptase real-time PCR (RT-rPCR) assay targeting the IHNV nucleocapsid (N) gene. Properties of diagnostic sensitivity (DSe) and specificity (DSp) were defined using laboratory-challenged steelhead trout Oncorhynchus mykiss, and the new assay was compared to the OIE-accepted conventional PCR test and virus isolation in cell culture. The IHNV N gene RT-rPCR had 100% DSp and DSe and a higher estimated diagnostic odds ratio (DOR) than virus culture or conventional PCR. The RT-rPCR assay was highly repeatable within a laboratory and highly reproducible between laboratories. Field testing of the assay was conducted on a random sample of juvenile steelhead collected from a hatchery raceway experiencing an IHN epizootic. The RT-rPCR detected a greater number of positive samples than cell culture and there was 40% agreement between the 2 tests. Overall, the RT-rPCR assay was highly sensitive, specific, repeatable and reproducible and is suitable for use in a diagnostic setting.

  1. Diagnostics in a digital age: an opportunity to strengthen health systems and improve health outcomes.

    PubMed

    Peeling, Rosanna W

    2015-11-01

    Diagnostics play a critical role in clinical decision making, and in disease control and prevention. Rapid point-of-care (POC) tests for infectious diseases can improve access to diagnosis and patient management, but the quality of these tests vary, quality of testing is often not assured and there are few mechanisms to capture test results for surveillance when the testing is so decentralised. A new generation of POC molecular tests that are highly sensitive and specific, robust and easy to use are now available for deployment in low resource settings. Decentralisation of testing outside of the laboratory can put tremendous stress on the healthcare system and presents challenges for training and quality assurance. A feature of many of these POC molecular devices is that they are equipped with data transmission capacities. In a digital age, it is possible to link data from diagnostic laboratories and POC test readers and devices to provide data on testing coverage, disease trends and timely information for early warning of infectious disease outbreaks to inform design or optimisation of disease control and elimination programmes. Data connectivity also allows control programmes to monitor the quality of tests and testing, and optimise supply chain management; thus, increasing the efficiency of healthcare systems and improving patient outcomes. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  2. Alchemy: A Web 2.0 Real-time Quality Assurance Platform for Human Immunodeficiency Virus, Hepatitis C Virus, and BK Virus Quantitation Assays

    PubMed Central

    Agosto-Arroyo, Emmanuel; Coshatt, Gina M.; Winokur, Thomas S.; Harada, Shuko; Park, Seung L.

    2017-01-01

    Background: The molecular diagnostics laboratory faces the challenge of improving test turnaround time (TAT). Low and consistent TATs are of great clinical and regulatory importance, especially for molecular virology tests. Laboratory information systems (LISs) contain all the data elements necessary to do accurate quality assurance (QA) reporting of TAT and other measures, but these reports are in most cases still performed manually: a time-consuming and error-prone task. The aim of this study was to develop a web-based real-time QA platform that would automate QA reporting in the molecular diagnostics laboratory at our institution, and minimize the time expended in preparing these reports. Methods: Using a standard Linux, Nginx, MariaDB, PHP stack virtual machine running atop a Dell Precision 5810, we designed and built a web-based QA platform, code-named Alchemy. Data files pulled periodically from the LIS in comma-separated value format were used to autogenerate QA reports for the human immunodeficiency virus (HIV) quantitation, hepatitis C virus (HCV) quantitation, and BK virus (BKV) quantitation. Alchemy allowed the user to select a specific timeframe to be analyzed and calculated key QA statistics in real-time, including the average TAT in days, tests falling outside the expected TAT ranges, and test result ranges. Results: Before implementing Alchemy, reporting QA for the HIV, HCV, and BKV quantitation assays took 45–60 min of personnel time per test every month. With Alchemy, that time has decreased to 15 min total per month. Alchemy allowed the user to select specific periods of time and analyzed the TAT data in-depth without the need of extensive manual calculations. Conclusions: Alchemy has significantly decreased the time and the human error associated with QA report generation in our molecular diagnostics laboratory. Other tests will be added to this web-based platform in future updates. This effort shows the utility of informatician-supervised resident/fellow programming projects as learning opportunities and workflow improvements in the molecular laboratory. PMID:28480121

  3. Point-of-care oral-based diagnostics

    PubMed Central

    Hart, RW; Mauk, MG; Liu, C; Qiu, X; Thompson, JA; Chen, D; Malamud, D; Abrams, WR; Bau, HH

    2014-01-01

    Many of the target molecules that reside in blood are also present in oral fluids, albeit at lower concentrations. Oral fluids are, however, relatively easy and safe to collect without the need for specialized equipment and training. Thus, oral fluids provide convenient samples for medical diagnostics. Recent advances in lab-on-a-chip technologies have made minute, fully integrated diagnostic systems practical for an assortment of point-of-care tests. Such systems can perform either immunoassays or molecular diagnostics outside centralized laboratories within time periods ranging from minutes to an hour. The article briefly reviews recent advances in devices for point-of-care testing with a focus on work that has been carried out by the authors as part of a NIH program. PMID:21521419

  4. The Air Force Phillips Laboratory multimegawatt quasi-steady MPD thruster facility

    NASA Astrophysics Data System (ADS)

    Castillo, Salvador; Tilley, Dennis L.

    1992-07-01

    The operational multimegawatt quasi-steady MPD thruster facility is described in terms of its general design emphasizing the impulse thrust stand and diagnostics capabilities. The vacuum, propellant, and electrical systems are discussed with schematic diagrams of the respective component configurations and explanations of the needs of MPD thruster testing. The impulse thrust stand comprises an accelerometer/pendulum-impulse stand which can be used to correlate thruster impulse with accelerometer readings and thereby reduce measurement uncertainties. The diagnostics of the terminal characteristics of the thruster operation are complemented by diagnostics platforms that study plasma properties in the plume and the thruster. Preliminary tests indicate that the MPD thruster facility is prepared for detailed investigations of MPD thruster performance and plume diagnostics.

  5. Exploring New Ways to Deliver Value to Healthcare Organizations: Algorithmic Testing, Data Integration, and Diagnostic E-consult Service.

    PubMed

    Risin, Semyon A; Chang, Brian N; Welsh, Kerry J; Kidd, Laura R; Moreno, Vanessa; Chen, Lei; Tholpady, Ashok; Wahed, Amer; Nguyen, Nghia; Kott, Marylee; Hunter, Robert L

    2015-01-01

    As the USA Health Care System undergoes transformation and transitions to value-based models it is critical for laboratory medicine/clinical pathology physicians to explore opportunities and find new ways to deliver value, become an integral part of the healthcare team. This is also essential for ensuring financial health and stability of the profession when the payment paradigm changes from fee-for-service to fee-for-performance. About 5 years ago we started searching for ways to achieve this goal. Among other approaches, the search included addressing the laboratory work-ups for specialists' referrals in the HarrisHealth System, a major safety net health care organization serving mostly indigent and underserved population of Harris County, TX. We present here our experience in improving the efficiency of laboratory testing for the referral process and in building a prototype of a diagnostic e-consult service using rheumatologic diseases as a starting point. The service incorporates algorithmic testing, integration of clinical, laboratory and imaging data, issuing structured comprehensive consultation reports, incorporating all the relevant information, and maintaining personal contacts and an e-line of communications with the primary providers and referral center personnel. Ongoing survey of providers affords testimony of service value in terms of facilitating their work and increasing productivity. Analysis of the cost effectiveness and of other value indicators is currently underway. We also discuss our pioneering experience in building pathology residents and fellows training in integrated diagnostic consulting service. © 2015 by the Association of Clinical Scientists, Inc.

  6. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...

  7. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...

  8. 42 CFR 414.502 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...

  9. Dengue

    MedlinePlus

    ... and laboratorians... Dengue Training Opportunities Dengue educational tools... Dengue Travel Health Notices Other travel health notices Get ... Clinicians Laboratory Guidance and Diagnostic Testing Epidemiologists Journalists Dengue Branch News Dengue and Climate Dengue Update About ...

  10. Laboratory capacity for diagnosis of foot-and-mouth disease in Eastern Africa: implications for the progressive control pathway.

    PubMed

    Namatovu, Alice; Wekesa, Sabenzia Nabalayo; Tjørnehøj, Kirsten; Dhikusooka, Moses Tefula; Muwanika, Vincent B; Siegsmund, Hans Redlef; Ayebazibwe, Chrisostom

    2013-01-24

    Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006-2010. The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples.

  11. Laboratory capacity for diagnosis of foot-and-mouth disease in Eastern Africa: implications for the progressive control pathway

    PubMed Central

    2013-01-01

    Background Accurate diagnosis is pertinent to any disease control programme. If Eastern Africa is to work towards control of foot-and-mouth disease (FMD) using the Progressive Control Pathway for FMD (PCP-FMD) as a tool, then the capacity of national reference laboratories (NRLs) mandated to diagnose FMD should match this task. This study assessed the laboratory capacity of 14 NRLs of the Eastern Africa Region Laboratory Network member countries using a semi-structured questionnaire and retrospective data from the World Reference Laboratory for FMD annual reports and Genbank® through National Centre for Biotechnology Information for the period 2006–2010. Results The questionnaire response rate was 13/14 (93%). Twelve out of the 13 countries/regions had experienced at least one outbreak in the relevant five year period. Only two countries (Ethiopia and Kenya) had laboratories at biosecurity level 3 and only three (Ethiopia, Kenya and Sudan) had identified FMD virus serotypes for all reported outbreaks. Based on their own country/region assessment, 12/13 of these countries /regions were below stage 3 of the PCP-FMD. Quarantine (77%) and vaccination (54%) were the major FMD control strategies employed. The majority (12/13) of the NRLs used serological techniques to diagnose FMD, seven used antigen ELISA and three of these (25%) also used molecular techniques which were the tests most frequently requested from collaborating laboratories by the majority (69%) of the NRLs. Only 4/13 (31%) participated in proficiency testing for FMD. Four (31%) laboratories had no quality management systems (QMS) in place and where QMS existed it was still deficient, thus, none of the laboratories had achieved accreditation for FMD diagnosis. Conclusions This study indicates that FMD diagnostic capacity in Eastern Africa is still inadequate and largely depends on antigen and antibody ELISAs techniques undertaken by the NRLs. Hence, for the region to progress on the PCP-FMD, there is need to: implement regional control measures, improve the serological diagnostic test performance and laboratory capacity of the NRLs (including training of personnel as well as upgrading of equipment and methods, especially strengthening the molecular diagnostic capacity), and to establish a regional reference laboratory to enforce QMS and characterization of FMD virus containing samples. PMID:23347795

  12. Evaluation of the NanoCHIP® Gastrointestinal Panel (GIP) Test for Simultaneous Detection of Parasitic and Bacterial Enteric Pathogens in Fecal Specimens

    PubMed Central

    Ken Dror, Shifra; Pavlotzky, Elsa; Barak, Mira

    2016-01-01

    Infectious gastroenteritis is a global health problem associated with high morbidity and mortality rates. Rapid and accurate diagnosis is crucial to allow appropriate and timely treatment. Current laboratory stool testing has a long turnaround time (TAT) and demands highly qualified personnel and multiple techniques. The need for high throughput and the number of possible enteric pathogens compels the implementation of a molecular approach which uses multiplex technology, without compromising performance requirements. In this work we evaluated the feasibility of the NanoCHIP® Gastrointestinal Panel (GIP) (Savyon Diagnostics, Ashdod, IL), a molecular microarray-based screening test, to be used in the routine workflow of our laboratory, a big outpatient microbiology laboratory. The NanoCHIP® GIP test provides simultaneous detection of nine major enteric bacteria and parasites: Campylobacter spp., Salmonella spp., Shigella spp., Giardia sp., Cryptosporidium spp., Entamoeba histolytica, Entamoeba dispar, Dientamoeba fragilis, and Blastocystis spp. The required high-throughput was obtained by the NanoCHIP® detection system together with the MagNA Pure 96 DNA purification system (Roche Diagnostics Ltd., Switzerland). This combined system has demonstrated a higher sensitivity and detection yield compared to the conventional methods in both, retrospective and prospective samples. The identification of multiple parasites and bacteria in a single test also enabled increased efficiency of detecting mixed infections, as well as reduced hands-on time and work load. In conclusion, the combination of these two automated systems is a proper response to the laboratory needs in terms of improving laboratory workflow, turn-around-time, minimizing human errors and can be efficiently integrated in the routine work of the laboratory. PMID:27447173

  13. Antenatal screening for Down syndrome: a quantitative demonstration of the improvements over the past 20 years.

    PubMed

    Renshaw, Richard; Ellis, Katrina; Jacobs, Patricia; Morris, Joan

    2013-10-01

    Pregnant women who receive a high screening risk result for Down, Edwards or Patau syndrome are offered diagnostic tests that carry a procedure-related risk of miscarriage. This study quantifies the improvement in the screening tests by calculating the number of women who had such tests per syndrome diagnosis from 1991 to 2010. Routinely stored data on prenatal chorionic villus sampling (CVS) and amniocentesis samples performed from 1991 to 2010 from the Wessex Regional Genetics Laboratory in England were extracted from the laboratory database. The numbers of diagnostic tests performed per Down, Edwards or Patau syndrome diagnosis were calculated according to the type of diagnostic test, and were adjusted for maternal age and gestational age at diagnosis. A total of 32,345 CVSs and amniocenteses identified 872 diagnoses of Down syndrome and 328 of Edwards and Patau syndrome. In 1991, there were 46 (95%CI: 16-111) CVSs per syndrome diagnosis compared with five (95%CI: 4-7) in 2010. For amniocenteses, the number fell from 53 (37-78) to 15 (11-22). This analysis demonstrates the improvements in antenatal screening for Down syndrome that have been made over the past 20 years, resulting in a reduction in the number of women tested and thus in the number of foetal deaths attributable to the testing procedure.

  14. Adoption of lean principles in a high-volume molecular diagnostic microbiology laboratory.

    PubMed

    Mitchell, P Shawn; Mandrekar, Jayawant N; Yao, Joseph D C

    2014-07-01

    Clinical laboratories are constantly facing challenges to do more with less, enhance quality, improve test turnaround time, and reduce operational expenses. Experience with adopting and applying lean concepts and tools used extensively in the manufacturing industry is described for a high-volume clinical molecular microbiology laboratory, illustrating how operational success and benefits can be achieved. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  15. The role of postictal laboratory blood analyses in the diagnosis and prognosis of seizures.

    PubMed

    Nass, Robert D; Sassen, Robert; Elger, Christian E; Surges, Rainer

    2017-04-01

    Epileptic seizures (ES) lead to alterations in the blood laboratory values and reflect changes in different organ systems. Here, we review the diagnostic and prognostic value of various blood laboratory values within the context of epilepsy. Narrative review and literature search on PubMed using the term, "seizure" and various laboratory values. Laboratory markers can help clinicians determine whether an unwitnessed event was more likely to be epileptic or non-epileptic. Prolactin testing helps differentiate ES from psychogenic non-epileptic seizures (PNES) in adults and adolescents, and is associated with high specificity and moderate sensitivity. Elevations in the creatine kinase (CK) levels are common after generalized tonic-clonic seizures (GTCS) and display high specificity and moderate sensitivity. Metabolic markers such as ammonia and lactate may have diagnostic potential for postictal blood tests. Analyzing blood postictally is important for identifying the cause of the symptomatic seizures due to endocrine, metabolic, toxic or infectious etiologies. Finally, laboratory analyses are used for identifying patients who are at risk for developing rare, threatening complications such as rhabdomyolysis, acute renal failure (ARF) or cardiomyopathy. Presently, no postictal laboratory values can definitively prove or rule out the diagnosis of an epileptic seizure. For seizures with unknown causes, simple blood tests can be a valuable aid for quickly defining the etiology, particularly with certain metabolic and toxic encephalopathies. For this reason, CK, electrolytes, creatinine, liver and renal function tests should be measured on at least one occasion. Further research is needed in order to identify new biomarkers that improve the diagnosis and prognosis of seizures and seizure-related complications. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  16. Laboratory diagnostics of malaria

    NASA Astrophysics Data System (ADS)

    Siahaan, L.

    2018-03-01

    Even now, malaria treatment should only be administered after laboratory confirmation. There are several principal methods for diagnosing malaria. All these methods have their disadvantages.Presumptive treatment of malaria is widely practiced where laboratory tests are not readily available. Microscopy of Giemsa-stained thick and thin blood films remains the gold standard for the diagnosis of malaria infection. The technique of slide preparation, staining and reading are well known and standardized, and so is the estimate of the parasite density and parasite stages. Microscopy is not always available or feasible at primary health services in limited resource settings due to cost, lack of skilled manpower, accessories and reagents required. Rapid diagnostic tests (RDTs) are potential tools for parasite-based diagnosis since the tests are accurate in detecting malaria infections and are easy to use. The test is based on the capture of parasite antigen that released from parasitized red blood cells using monoclonal antibodies prepared against malaria antigen target. Polymerase Chain Reaction (PCR), depend on DNA amplification approaches and have higher sensitivity than microscopy. PCR it is not widely used due to the lack of a standardized methodology, high costs, and the need for highly-trained staff.

  17. Legionnaire's Disease: A Clinical Diagnostic Approach.

    PubMed

    Cunha, Burke A; Cunha, Cheston B

    2017-03-01

    Legionnaire's disease is a nonzoonotic atypical pneumonia caused by Legionella sp that occurs sporadically or in outbreaks. Legionnaire's disease pneumonia is accompanied by several extrapulmonary clinical and laboratory findings. Rather than testing all pneumonias for Legionnaire's disease, the clinical challenge is to recognize the diagnostic significance of Legionnaire's disease's. The pretest probability of Legionnaire's disease is increased if several characteristic extrapulmonary findings are present. Similarly, if certain key findings are absent, Legionnaire's disease may be eliminated from further diagnostic consideration. If characteristic clinical findings are present, then specific tests should be ordered to confirm or rule out Legionnaire's disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  19. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  20. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  1. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  2. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  3. Lyme Disease Testing in a High-Incidence State: Clinician Knowledge and Patterns.

    PubMed

    Conant, Joanna L; Powers, Julia; Sharp, Gregory; Mead, Paul S; Nelson, Christina A

    2018-02-17

    Lyme disease (LD) incidence is increasing, but data suggest some clinicians are not fully aware of recommended procedures for ordering and interpreting diagnostic tests. The study objective was to assess clinicians' knowledge and practices regarding LD testing in a high-incidence region. We distributed surveys to 1,142 clinicians in the University of Vermont Medical Center region, of which 144 were completed (12.6% response rate). We also examined LD laboratory test results and logs of calls to laboratory customer service over a period of 2.5 years and 6 months, respectively. Most clinicians demonstrated basic knowledge of diagnostic protocols, but many misinterpreted Western blot results. For example, 42.4% incorrectly interpreted a positive immunoglobulin M result as an overall positive test in a patient with longstanding symptoms. Many also reported receiving patient requests for unvalidated tests. Additional education and modifications to LD test ordering and reporting systems would likely reduce errors and improve patient care. © American Society for Clinical Pathology, 2018. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  4. Improving Accuracy of Influenza-Associated Hospitalization Rate Estimates

    PubMed Central

    Reed, Carrie; Kirley, Pam Daily; Aragon, Deborah; Meek, James; Farley, Monica M.; Ryan, Patricia; Collins, Jim; Lynfield, Ruth; Baumbach, Joan; Zansky, Shelley; Bennett, Nancy M.; Fowler, Brian; Thomas, Ann; Lindegren, Mary L.; Atkinson, Annette; Finelli, Lyn; Chaves, Sandra S.

    2015-01-01

    Diagnostic test sensitivity affects rate estimates for laboratory-confirmed influenza–associated hospitalizations. We used data from FluSurv-NET, a national population-based surveillance system for laboratory-confirmed influenza hospitalizations, to capture diagnostic test type by patient age and influenza season. We calculated observed rates by age group and adjusted rates by test sensitivity. Test sensitivity was lowest in adults >65 years of age. For all ages, reverse transcription PCR was the most sensitive test, and use increased from <10% during 2003–2008 to ≈70% during 2009–2013. Observed hospitalization rates per 100,000 persons varied by season: 7.3–50.5 for children <18 years of age, 3.0–30.3 for adults 18–64 years, and 13.6–181.8 for adults >65 years. After 2009, hospitalization rates adjusted by test sensitivity were ≈15% higher for children <18 years, ≈20% higher for adults 18–64 years, and ≈55% for adults >65 years of age. Test sensitivity adjustments improve the accuracy of hospitalization rate estimates. PMID:26292017

  5. Diagnostic doses and times for Phlebotomus papatasi and Lutzomyia longipalpis sand flies (Diptera: Psychodidae: Phlebotominae) using the CDC bottle bioassay to assess insecticide resistance.

    PubMed

    Denlinger, David S; Creswell, Joseph A; Anderson, J Laine; Reese, Conor K; Bernhardt, Scott A

    2016-04-15

    Insecticide resistance to synthetic chemical insecticides is a worldwide concern in phlebotomine sand flies (Diptera: Psychodidae), the vectors of Leishmania spp. parasites. The CDC bottle bioassay assesses resistance by testing populations against verified diagnostic doses and diagnostic times for an insecticide, but the assay has been used limitedly with sand flies. The objective of this study was to determine diagnostic doses and diagnostic times for laboratory Lutzomyia longipalpis (Lutz & Nieva) and Phlebotomus papatasi (Scopoli) to ten insecticides, including pyrethroids, organophosphates, carbamates, and DDT, that are used worldwide to control vectors. Bioassays were conducted in 1,000-ml glass bottles each containing 10-25 sand flies from laboratory colonies of L. longipalpis or P. papatasi. Four pyrethroids, three organophosphates, two carbamates and one organochlorine, were evaluated. A series of concentrations were tested for each insecticide, and four replicates were conducted for each concentration. Diagnostic doses were determined only during the exposure bioassay for the organophosphates and carbamates. For the pyrethroids and DDT, diagnostic doses were determined for both the exposure bioassay and after a 24-hour recovery period. Both species are highly susceptible to the carbamates as their diagnostic doses are under 7.0 μg/ml. Both species are also highly susceptible to DDT during the exposure assay as their diagnostic doses are 7.5 μg/ml, yet their diagnostic doses for the 24-h recovery period are 650.0 μg/ml for Lu. longipalpis and 470.0 μg/ml for P. papatasi. Diagnostic doses and diagnostic times can now be incorporated into vector management programs that use the CDC bottle bioassay to assess insecticide resistance in field populations of Lu. longipalpis and P. papatasi. These findings provide initial starting points for determining diagnostic doses and diagnostic times for other sand fly vector species and wild populations using the CDC bottle bioassay.

  6. 21 CFR 660.44 - Specificity.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.44 Specificity. Each filling of the product shall be specific for Hepatitis B Surface Antigen as determined by...

  7. 21 CFR 660.44 - Specificity.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.44 Specificity. Each filling of the product shall be specific for Hepatitis B Surface Antigen as determined by...

  8. 21 CFR 660.44 - Specificity.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.44 Specificity. Each filling of the product shall be specific for Hepatitis B Surface Antigen as determined by...

  9. 21 CFR 660.44 - Specificity.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.44 Specificity. Each filling of the product shall be specific for Hepatitis B Surface Antigen as determined by...

  10. [Diagnostic kits in parasitology: which controls?].

    PubMed

    Rossi, P

    2004-06-01

    The development of new diagnostic tools particularly for some parasitic "neglected diseases", is slowed or even hindered by limited resources assigned for basic and applied research in public institution and private sector. Even if the time-line and costs needed for developing a new In Vitro Diagnostic (IVD) test are generally lower compared to vaccines or new drugs, industry is poorly engaged in investing resources due to the perception of limited markets. To accelerate the development of diagnostics for the world's most deadly diseases, the World Health Organization's (WHO) Special Programme for Research and Training in Tropical Diseases (TDR), the United Nations Development Programme, the World Bank and the Gates Foundation, last year launched a new initiative, FIND (Foundation for Innovative New Diagnostics, www.finddiagnostics.org). The aim is to "apply the latest biotechnology innovations to develop and validate affordable diagnostic tests for diseases of the developing world". Ideally, a new diagnostic test should be accurately evaluated prior to use in medical practice. The first step would be a pre-clinical evaluation, an analytic study to determine its laboratory performance. A crucial point in this phase is the calibration of reagents (antigens, antibodies, DNA probes, etc.) against a standard reference preparation. WHO, through the WHO International Laboratories for Biological Standards, "provides International Biological Reference Preparations which serve as reference sources of defined biological activity expressed in an internationally agreed unit" (www.who.int/biologicals/IBRP/index.htm). Standardization allows "comparison of biological measurements worldwide" and ensures the reliability of diagnostic procedures. These preparations are generally intended for use in the characterization of the activity of secondary reference preparations (regional, national or in-house working standards). Unfortunately, international reference standards for parasitic diseases are not available at present, except for Toxoplasma antibodies. The first international standard reagent for Anti-Toxoplasma Serum was established in 1968 and at present, an international standard reference serum, Anti-toxoplasma serum, human TOXM is available at the National Institute for Biological Standards and Control (NIBSC) in UK. Several collaborative, multicenter studies were carried out to assess the performance of different methods and commercial tests for the diagnosis of toxoplasmosis, by providing to participating laboratories a panel of well-defined sera to be tested. A four-phase process following well-accepted methodological standards for the development of diagnostics, analogous to those internationally accepted for drugs and vaccines was recently proposed. The pre-clinical evaluation, the analytic study to assess sensitivity, specificity, predictive values in laboratory (phase I), should be followed by a proof of principle study to distinguish diseased from healthy persons in easily accessible populations (phase II). The evaluation of test performance in populations of intended use (phase III), and finally the delineation of cost-effectiveness and societal impact of new tests in comparison with existing tools (phase IV) should complete the validation procedure. In this context, national regulatory agencies play a major role in pre-market approval and post-market surveillance of IVDs. The European Community in 1998 approved a directive (Directive 98/79/EC) which rules the marketing of IVD medical devices, in order to harmonise the performance levels and standards in European countries. But, among IVDs for parasitic diseases, only those to detect congenital toxoplasmosis are submitted to defined procedures to provide the verification of products before their placing on the market and the surveillance after their marketing by a notified body, which perform appropriate examinations, tests and inspections to production facilities to verify if the device meets the requirements of the directive. In U.S.A., the Food and Drug Administration (FDA), through the Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD), provides a comprehensive and regulatory activity for IVDs through pre-market evaluation and post-market surveillance. In developing countries, the scarcity of resources limits the procedures through which the national control authority can assure safety, quality and efficacy of products marketed, both imported and locally manufactured.

  11. Simpler score of routine laboratory tests predicts liver fibrosis in patients with chronic hepatitis B.

    PubMed

    Zhou, Kun; Gao, Chun-Fang; Zhao, Yun-Peng; Liu, Hai-Lin; Zheng, Rui-Dan; Xian, Jian-Chun; Xu, Hong-Tao; Mao, Yi-Min; Zeng, Min-De; Lu, Lun-Gen

    2010-09-01

    In recent years, a great interest has been dedicated to the development of noninvasive predictive models to substitute liver biopsy for fibrosis assessment and follow-up. Our aim was to provide a simpler model consisting of routine laboratory markers for predicting liver fibrosis in patients chronically infected with hepatitis B virus (HBV) in order to optimize their clinical management. Liver fibrosis was staged in 386 chronic HBV carriers who underwent liver biopsy and routine laboratory testing. Correlations between routine laboratory markers and fibrosis stage were statistically assessed. After logistic regression analysis, a novel predictive model was constructed. This S index was validated in an independent cohort of 146 chronic HBV carriers in comparison to the SLFG model, Fibrometer, Hepascore, Hui model, Forns score and APRI using receiver operating characteristic (ROC) curves. The diagnostic values of each marker panels were better than single routine laboratory markers. The S index consisting of gamma-glutamyltransferase (GGT), platelets (PLT) and albumin (ALB) (S-index: 1000 x GGT/(PLT x ALB(2))) had a higher diagnostic accuracy in predicting degree of fibrosis than any other mathematical model tested. The areas under the ROC curves (AUROC) were 0.812 and 0.890 for predicting significant fibrosis and cirrhosis in the validation cohort, respectively. The S index, a simpler mathematical model consisting of routine laboratory markers predicts significant fibrosis and cirrhosis in patients with chronic HBV infection with a high degree of accuracy, potentially decreasing the need for liver biopsy.

  12. Multiplex PCR Tests for Detection of Pathogens Associated with Gastroenteritis

    PubMed Central

    Zhang, Hongwei; Morrison, Scott; Tang, Yi-Wei

    2016-01-01

    Synopsis A wide range of enteric pathogens can cause infectious gastroenteritis. Conventional diagnostic algorithms including culture, biochemical identification, immunoassay and microscopic examination are time consuming and often lack sensitivity and specificity. Advances in molecular technology have as allowed its use as clinical diagnostic tools. Multiplex PCR based testing has made its way to gastroenterology diagnostic arena in recent years. In this article we present a review of recent laboratory developed multiplex PCR tests and current commercial multiplex gastrointestinal pathogen tests. We will focus on two FDA cleared commercial syndromic multiplex tests: Luminex xTAG GPP and Biofire FimArray GI test. These multiplex tests can detect and identify multiple enteric pathogens in one test and provide results within hours. Multiplex PCR tests have shown superior sensitivity to conventional methods for detection of most pathogens. The high negative predictive value of these multiplex tests has led to the suggestion that they be used as screening tools especially in outbreaks. Although the clinical utility and benefit of multiplex PCR test are to be further investigated, implementing these multiplex PCR tests in gastroenterology diagnostic algorithm has the potential to improve diagnosis of infectious gastroenteritis. PMID:26004652

  13. Quality in the molecular microbiology laboratory.

    PubMed

    Wallace, Paul S; MacKay, William G

    2013-01-01

    In the clinical microbiology laboratory advances in nucleic acid detection, quantification, and sequence analysis have led to considerable improvements in the diagnosis, management, and monitoring of infectious diseases. Molecular diagnostic methods are routinely used to make clinical decisions based on when and how to treat a patient as well as monitor the effectiveness of a therapeutic regime and identify any potential drug resistant strains that may impact on the long term patient treatment program. Therefore, confidence in the reliability of the result provided by the laboratory service to the clinician is essential for patient treatment. Hence, suitable quality assurance and quality control measures are important to ensure that the laboratory methods and service meet the necessary regulatory requirements both at the national and international level. In essence, the modern clinical microbiology laboratory ensures the appropriateness of its services through a quality management system that monitors all aspects of the laboratory service pre- and post-analytical-from patient sample receipt to reporting of results, from checking and upholding staff competency within the laboratory to identifying areas for quality improvements within the service offered. For most European based clinical microbiology laboratories this means following the common International Standard Organization (ISO9001) framework and ISO15189 which sets out the quality management requirements for the medical laboratory (BS EN ISO 15189 (2003) Medical laboratories-particular requirements for quality and competence. British Standards Institute, Bristol, UK). In the United States clinical laboratories performing human diagnostic tests are regulated by the Centers for Medicare and Medicaid Services (CMS) following the requirements within the Clinical Laboratory Improvement Amendments document 1988 (CLIA-88). This chapter focuses on the key quality assurance and quality control requirements within the modern microbiology laboratory providing molecular diagnostics.

  14. Battery testing at Argonne National Laboratory

    NASA Astrophysics Data System (ADS)

    Deluca, W. H.; Gillie, K. R.; Kulaga, J. E.; Smaga, J. A.; Tummillo, A. F.; Webster, C. E.

    1993-03-01

    Argonne National Laboratory's Analysis & Diagnostic Laboratory (ADL) tests advanced batteries under simulated electric and hybrid vehicle operating conditions. The ADL facilities also include a post-test analysis laboratory to determine, in a protected atmosphere if needed, component compositional changes and failure mechanisms. The ADL provides a common basis for battery performance characterization and life evaluations with unbiased application of tests and analyses. The battery evaluations and post-test examinations help identify factors that limit system performance and life and the most-promising R&D approaches for overcoming these limitations. Since 1991, performance characterizations and/or life evaluations have been conducted on eight battery technologies: Na/S, Li/S, Zn/Br, Ni/MH, Ni/Zn, Ni/Cd, Ni/Fe, and lead-acid. These evaluations were performed for the Department of Energy's. Office of Transportation Technologies, Electric and Hybrid Propulsion Division (DOE/OTT/EHP), and Electric Power Research Institute (EPRI) Transportation Program. The results obtained are discussed.

  15. Nonproliferative and Proliferative Lesions of the Gastrointestinal Tract, Pancreas and Salivary Glands of the Rat and Mouse.

    PubMed

    Nolte, Thomas; Brander-Weber, Patricia; Dangler, Charles; Deschl, Ulrich; Elwell, Michael R; Greaves, Peter; Hailey, Richard; Leach, Michael W; Pandiri, Arun R; Rogers, Arlin; Shackelford, Cynthia C; Spencer, Andrew; Tanaka, Takuji; Ward, Jerrold M

    2016-01-01

    The INHAND (International Harmonization of Nomenclature and Diagnostic Criteria for Lesions in Rats and Mice) project is a joint initiative of the Societies of Toxicologic Pathology from Europe (ESTP), Great Britain (BSTP), Japan (JSTP), and North America (STP) to develop an internationally accepted nomenclature and diagnostic criteria for nonproliferative and proliferative lesions in laboratory animals. The purpose of this publication is to provide a standardized nomenclature and diagnostic criteria for classifying lesions in the digestive system including the salivary glands and the exocrine pancreas of laboratory rats and mice. Most lesions are illustrated by color photomicrographs. The standardized nomenclature, the diagnostic criteria, and the photomicrographs are also available electronically on the Internet (http://www.goreni.org/). Sources of material included histopathology databases from government, academia, and industrial laboratories throughout the world. Content includes spontaneous and age related lesions as well as lesions induced by exposure to test items. Relevant infectious and parasitic lesions are included as well. A widely accepted and utilized international harmonization of nomenclature and diagnostic criteria for the digestive system will decrease misunderstandings among regulatory and scientific research organizations in different countries and provide a common language to increase and enrich international exchanges of information among toxicologists and pathologists.

  16. Nonproliferative and Proliferative Lesions of the Gastrointestinal Tract, Pancreas and Salivary Glands of the Rat and Mouse

    PubMed Central

    Nolte, Thomas; Brander-Weber, Patricia; Dangler, Charles; Deschl, Ulrich; Elwell, Michael R.; Greaves, Peter; Hailey, Richard; Leach, Michael W.; Pandiri, Arun R.; Rogers, Arlin; Shackelford, Cynthia C.; Spencer, Andrew; Tanaka, Takuji; Ward, Jerrold M.

    2016-01-01

    The INHAND (International Harmonization of Nomenclature and Diagnostic Criteria for Lesions in Rats and Mice) project is a joint initiative of the Societies of Toxicologic Pathology from Europe (ESTP), Great Britain (BSTP), Japan (JSTP), and North America (STP) to develop an internationally accepted nomenclature and diagnostic criteria for nonproliferative and proliferative lesions in laboratory animals. The purpose of this publication is to provide a standardized nomenclature and diagnostic criteria for classifying lesions in the digestive system including the salivary glands and the exocrine pancreas of laboratory rats and mice. Most lesions are illustrated by color photomicrographs. The standardized nomenclature, the diagnostic criteria, and the photomicrographs are also available electronically on the Internet (http://www.goreni.org/). Sources of material included histopathology databases from government, academia, and industrial laboratories throughout the world. Content includes spontaneous and age related lesions as well as lesions induced by exposure to test items. Relevant infectious and parasitic lesions are included as well. A widely accepted and utilized international harmonization of nomenclature and diagnostic criteria for the digestive system will decrease misunderstandings among regulatory and scientific research organizations in different countries and provide a common language to increase and enrich international exchanges of information among toxicologists and pathologists. PMID:26973378

  17. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 – 2016 Ebola outbreak in West Africa

    PubMed Central

    Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-01-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied. PMID:28459810

  18. External quality assessment study for ebolavirus PCR-diagnostic promotes international preparedness during the 2014 - 2016 Ebola outbreak in West Africa.

    PubMed

    Ellerbrok, Heinz; Jacobsen, Sonja; Patel, Pranav; Rieger, Toni; Eickmann, Markus; Becker, Stephan; Günther, Stephan; Naidoo, Dhamari; Schrick, Livia; Keeren, Kathrin; Targosz, Angelina; Teichmann, Anette; Formenty, Pierre; Niedrig, Matthias

    2017-05-01

    During the recent Ebola outbreak in West Africa several international mobile laboratories were deployed to the mainly affected countries Guinea, Sierra Leone and Liberia to provide ebolavirus diagnostic capacity. Additionally, imported cases and small outbreaks in other countries required global preparedness for Ebola diagnostics. Detection of viral RNA by reverse transcription polymerase chain reaction has proven effective for diagnosis of ebolavirus disease and several assays are available. However, reliability of these assays is largely unknown and requires serious evaluation. Therefore, a proficiency test panel of 11 samples was generated and distributed on a global scale. Panels were analyzed by 83 expert laboratories and 106 data sets were returned. From these 78 results were rated optimal and 3 acceptable, 25 indicated need for improvement. While performance of the laboratories deployed to West Africa was superior to the overall performance there was no significant difference between the different assays applied.

  19. New Mexico Small Business Assistance (NMSBA) September 2016 Advisory Council Update

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larkin, Ariana Kayla

    This is an update on two projects headed by Los Alamos National Laboratory and Sandia National Laboratories. The two projects are: The Electrochemical Based Gas Analyzer for Automotive Diagnostic and Maximizing the Production of High Value and High Demand Guar Gum on Marginal Lands in New Mexico. The Electrochemical Based Gas Analyzer for Automotive Diagnostic NMSBA leveraged project is made up of Albuquerque companies, Automotive Test Solutions, Inc. (ATS), ATS Mobile Diagnostics and Thoma Technologies and Los Alamos small business, VI Control Systems, to develop a new sensor system for the automotive industry. The Guar Gum NMSBA Leveraged Project beganmore » in January 2016 with the goal to develop biotechnology to enable a genetic modification of prairie cordgrass, a renewable feedstock for bioenergy and bio-manufacturing. In the long term, the companies hope to use the technology to bio-manufacture high value products in the stem of the plant. This document describes the laboratories' cooperation with small businesses on these projects.« less

  20. Antimicrobial susceptibility of Escherichia coli F4, Pasteurella multocida, and Streptococcus suis isolates from a diagnostic veterinary laboratory and recommendations for a surveillance system

    PubMed Central

    Glass-Kaastra, Shiona K.; Pearl, David L.; Reid-Smith, Richard J.; McEwen, Beverly; Slavic, Durda; McEwen, Scott A.; Fairles, Jim

    2014-01-01

    Antimicrobial susceptibility data on Escherichia coli F4, Pasteurella multocida, and Streptococcus suis isolates from Ontario swine (January 1998 to October 2010) were acquired from a comprehensive diagnostic veterinary laboratory in Ontario, Canada. In relation to the possible development of a surveillance system for antimicrobial resistance, data were assessed for ease of management, completeness, consistency, and applicability for temporal and spatial statistical analyses. Limited farm location data precluded spatial analyses and missing demographic data limited their use as predictors within multivariable statistical models. Changes in the standard panel of antimicrobials used for susceptibility testing reduced the number of antimicrobials available for temporal analyses. Data consistency and quality could improve over time in this and similar diagnostic laboratory settings by encouraging complete reporting with sample submission and by modifying database systems to limit free-text data entry. These changes could make more statistical methods available for disease surveillance and cluster detection. PMID:24688133

  1. Antimicrobial susceptibility of Escherichia coli F4, Pasteurella multocida, and Streptococcus suis isolates from a diagnostic veterinary laboratory and recommendations for a surveillance system.

    PubMed

    Glass-Kaastra, Shiona K; Pearl, David L; Reid-Smith, Richard J; McEwen, Beverly; Slavic, Durda; McEwen, Scott A; Fairles, Jim

    2014-04-01

    Antimicrobial susceptibility data on Escherichia coli F4, Pasteurella multocida, and Streptococcus suis isolates from Ontario swine (January 1998 to October 2010) were acquired from a comprehensive diagnostic veterinary laboratory in Ontario, Canada. In relation to the possible development of a surveillance system for antimicrobial resistance, data were assessed for ease of management, completeness, consistency, and applicability for temporal and spatial statistical analyses. Limited farm location data precluded spatial analyses and missing demographic data limited their use as predictors within multivariable statistical models. Changes in the standard panel of antimicrobials used for susceptibility testing reduced the number of antimicrobials available for temporal analyses. Data consistency and quality could improve over time in this and similar diagnostic laboratory settings by encouraging complete reporting with sample submission and by modifying database systems to limit free-text data entry. These changes could make more statistical methods available for disease surveillance and cluster detection.

  2. Screening and syndromic approaches to identify gonorrhea and chlamydial infection among women.

    PubMed

    Sloan, N L; Winikoff, B; Haberland, N; Coggins, C; Elias, C

    2000-03-01

    The standard diagnostic tools to identify sexually transmitted infections are often expensive and have laboratory and infrastructure requirements that make them unavailable to family planning and primary health-care clinics in developing countries. Therefore, inexpensive, accessible tools that rely on symptoms, signs, and/or risk factors have been developed to identify and treat reproductive tract infections without the need for laboratory diagnostics. Studies were reviewed that used standard diagnostic tests to identify gonorrhea and cervical chlamydial infection among women and that provided adequate information about the usefulness of the tools for screening. Aggregation of the studies' results suggest that risk factors, algorithms, and risk scoring for syndromic management are poor indicators of gonorrhea and chlamydial infection in samples of both low and high prevalence and, consequently, are not effective mechanisms with which to identify or manage these conditions. The development and evaluation of other approaches to identify gonorrhea and chlamydial infections, including inexpensive and simple laboratory screening tools, periodic universal treatment, and other alternatives must be given priority.

  3. Design of a Tablet Computer App for Facilitation of a Molecular Blood Culture Test in Clinical Microbiology and Preliminary Usability Evaluation.

    PubMed

    Samson, Lasse L; Pape-Haugaard, Louise; Meltzer, Michelle C; Fuchs, Martin; Schønheyder, Henrik C; Hejlesen, Ole

    2016-03-18

    User mobility is an important aspect of the development of clinical information systems for health care professionals. Mobile phones and tablet computers have obtained widespread use by health care professionals, offering an opportunity for supporting the access to patient information through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). The objective of the study was to describe the design considerations of the MuxBCT app and the results of a preliminary usability evaluation. The MuxBCT tablet app was developed and set up for use in a clinical microbiology laboratory. A near-live simulation study was conducted in the clinical microbiology laboratory to evaluate the usability of the MuxBCT app. The study was designed to achieve a high degree of realism as participants carried out a scenario representing the context of use for the MuxBCT app. As the MuxBCT was under development, the scenario involved the use of molecular blood culture tests similar to the MuxBCT for identification of microorganisms from positive blood culture samples. The study participants were observed, and their interactions with the app were recorded. After the study, the participants were debriefed to clarify observations. Four medical laboratory technicians, for example, representative of end users of the app, participated in the clinical simulation study. Using the MuxBCT app, the study participants successfully identified and reported all microorganisms from the positive blood cultures examined. Three of the four participants reported that they found the app useful, while one study participant reported that she would prefer to make notes on paper and later enter them into the LIS. The preliminary usability evaluation results indicate that use of the MuxBCT tablet app can facilitate the workflow of the MuxBCT diagnostic test.

  4. Obstacles in the diagnostics and therapy of heparin-induced thrombocytopenia.

    PubMed

    Antonijević, Nebojsa M; Radovanović, Nebojsa; Obradović, Slobodan; Vucelić, Dragica; Stojanović, Bojan; Miković, Danijela; Kovac, Mirjana; Kocica, Tina; Tadić, Svetlana; Antonijević, Irina; Drasković, Snezana; Djordjević, Valentina; Calija, Branko; Perunicić, Jovan; Vasiljević, Zorana

    2010-01-01

    An immune-mediated, severe, acquired prothrombotic disorder, heparin-induced thrombocytopenia type II (HIT II) occurs in 0.5-5% of patients exposed to unfractionated heparin longer than 5-7 days. Arterial and venous thromboses are induced by HIT II in about 35-50% of patients. Typical death rate for HIT is about 29%, while 21% of HIT patients result in amputation of a limb. The trend towards the occurrence of HIT due to the administration of low molecular weight heparins (LMWH) taking ever conspicuous place in the standard venous thromboembolism (VTE) prophylaxis has been more frequently observed recently. It is considered that LMWH may cause HIT II in about 0.25-1%. The need for further modification of HIPA assays with LMWH has been imposed in the HIT laboratory diagnostics, heretofore overburdened with complexity. There are several constantly opposing problems arising in HIT laboratory diagnostics, one of which is that in a certain number of patients immunologic assays detect nonpathogenic antibodies (mainly IgM or IgA heparin-PF4 antibodies) while, on the other hand, the occurrence of HIT pathogenetically mediated by minor antigens (neutrophil-activating peptide 2 or interleukin 8) may be neglected in certain cases. The following factors play an important role in the interpretation of each laboratory HIT assays performed: 1. correlation with HIT clinical probability test, the best known of which is 4T'score, 2. the interpretation of the laboratory findings dependent on the time of the thrombocytopenia onset, as well as 3. the sensitivity and specificity of each test respectively. The HIT diagnostics in the presence of other comorbid states which may also induce thrombocytopenia, more precisely known as pseudo HIT (cancer, sepsis, disseminated intravascular coagulation, pulmonary embolism, antiphospholipid syndrome, etc), represents a specific clinical problem.

  5. Diagnostic performance of serological assays for anti-HBs testing: Results from a quality assessment program.

    PubMed

    Raven, Stijn; Hautvast, Jeannine; Steenbergen, Jim van; Akkermans, Reinier; Weykamp, Cas; Smits, Francis; Hoebe, Christian; Vossen, Ann

    2017-02-01

    Post-vaccination testing after hepatitis B vaccination is indispensable to evaluate long-term immunological protection. Using a threshold level of antibodies against hepatitis B surface antigen (anti-HBs) to define serological protection, implies reproducible and valid measurements of different diagnostic assays. In this study we assess the performance of currently used anti-HBs assays. In 2013, 45 laboratories participated in an external quality assessment program using pooled anti-HBs serum samples around the cutoff values 10IU/l and 100IU/l. Laboratories used either Axsym (Abbott Laboratories), Architect (Abbott Laboratories), Access (Beckman-Coulter), ADVIA Centaur anti-HBs2 (Siemens Healthcare Diagnostics), Elecsys, Modular or Cobas (Roche Diagnostics) or Vidas Total Quick (Biomerieux) for anti-HBs titre quantification. We analysed covariance using mixed-model repeated measures. To assess sensitivity/specificity and agreement, a true positive or true negative result was defined as an anti-HBs titre respectively above or below the cutoff value by ≥4 of 6 assays. Different anti-HBs assays were associated with statistically significant (P<0.05) differences in anti-HBs titres in all dilutions. Sensitivity and specificity ranged respectively from 64%-100% and 95%-100%. Agreement between assays around an anti-HBs titre cutoff value of 10IU/l ranged from 93%-100% and was 44% for a cutoff value of 100IU/l. Around a cutoff value of 10IU/l use of the Access assay may result in false-negative results. Concerning the cutoff value of 100IU/l, a sample being classified below or above this cutoff relied heavily on the specific assay used, with both the Architect and the Access resulting in false-negative results. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Trends in Testing for Mycobacterium tuberculosis Complex From US Public Health Laboratories, 2009-2013.

    PubMed

    Tyrrell, Frances; Stafford, Cortney; Yakrus, Mitchell; Youngblood, Monica; Hill, Andrew; Johnston, Stephanie

    We investigated data from US public health laboratories funded through the Centers for Disease Control and Prevention's Tuberculosis Elimination and Laboratory Cooperative Agreement to document trends and challenges in meeting national objectives in tuberculosis (TB) laboratory diagnoses. We examined data on workload and turnaround time from public health laboratories' progress reports during 2009-2013. We reviewed methodologies, laboratory roles, and progress toward rapid detection of Mycobacterium tuberculosis complex through nucleic acid amplification (NAA) testing. We compared selected data with TB surveillance reports to estimate public health laboratories' contribution to national diagnostic services. During the study period, culture and drug susceptibility tests decreased, but NAA testing increased. Public health laboratories achieved turnaround time benchmarks for drug susceptibility tests at lower levels than for acid-fast bacilli smear and identification from culture. NAA positivity in laboratories among surveillance-reported culture-positive TB cases increased from 26.6% (2355 of 8876) in 2009 to 40.0% (2948 of 7358) in 2013. Public health laboratories provided an estimated 50.9% (4285 of 8413 in 2010) to 57.2% (4210 of 7358 in 2013) of culture testing and 88.3% (6822 of 7727 in 2011) to 94.4% (6845 of 7250 in 2012) of drug susceptibility tests for all US TB cases. Public health laboratories contribute substantially to TB diagnoses in the United States. Although testing volumes mostly decreased, the increase in NAA testing indicates continued progress in rapid M tuberculosis complex detection.

  7. Diagnostic methods of TSH in thyroid screening tests.

    PubMed

    Matyjaszek-Matuszek, Beata; Pyzik, Aleksandra; Nowakowski, Andrzej; Jarosz, Mirosław J

    2013-01-01

    Reliable and quick thyreologic diagnostics, as well as verification of the effectiveness of the therapy undertaken, is of great importance for the state of health of society. The measurement of plasma TSH is the commonly accepted and most sensitive screening test for primary thyroid disorders, which are the most frequent diseases related to the endocrine glands. At present, the available methods for the determination of TSH are characterized by high sensitivity ≤0.01 µIU/ml and lack of cross-reactivity. However, many drugs and substances, as well as pathological conditions, may affect the TSH level. evaluation of contemporary laboratory methods for the determination of TSH and the principles of interpretation of screening tests. In many countries, the TSH test is the only test performed in the diagnostics of thyroid function; nevertheless, it seems that for genuine and objective assessment of thyroid status the TSH level, together with FT4 level, should be absolutely determined, which allows the differentiation and assessment of the intensity of thyroid function disorders and foresee its consequences. The interpretation of TSH results in screening tests is different in such population groups as: children aged under 14, pregnant women, the elderly, and patients with non-thyroidal illnesses. From among currently used laboratory methods for determination of TSH levels, third generation non-isotopic methods are most frequently recommended, especially the method of immunochemiluminescence.

  8. Guidelines for safe work practices in human and animal medical diagnostic laboratories. Recommendations of a CDC-convened, Biosafety Blue Ribbon Panel.

    PubMed

    Miller, J Michael; Astles, Rex; Baszler, Timothy; Chapin, Kimberle; Carey, Roberta; Garcia, Lynne; Gray, Larry; Larone, Davise; Pentella, Michael; Pollock, Anne; Shapiro, Daniel S; Weirich, Elizabeth; Wiedbrauk, Danny

    2012-01-06

    Prevention of injuries and occupational infections in U.S. laboratories has been a concern for many years. CDC and the National Institutes of Health addressed the topic in their publication Biosafety in Microbiological and Biomedical Laboratories, now in its 5th edition (BMBL-5). BMBL-5, however, was not designed to address the day-to-day operations of diagnostic laboratories in human and animal medicine. In 2008, CDC convened a Blue Ribbon Panel of laboratory representatives from a variety of agencies, laboratory organizations, and facilities to review laboratory biosafety in diagnostic laboratories. The members of this panel recommended that biosafety guidelines be developed to address the unique operational needs of the diagnostic laboratory community and that they be science based and made available broadly. These guidelines promote a culture of safety and include recommendations that supplement BMBL-5 by addressing the unique needs of the diagnostic laboratory. They are not requirements but recommendations that represent current science and sound judgment that can foster a safe working environment for all laboratorians. Throughout these guidelines, quality laboratory science is reinforced by a common-sense approach to biosafety in day-to-day activities. Because many of the same diagnostic techniques are used in human and animal diagnostic laboratories, the text is presented with this in mind. All functions of the human and animal diagnostic laboratory--microbiology, chemistry, hematology, and pathology with autopsy and necropsy guidance--are addressed. A specific section for veterinary diagnostic laboratories addresses the veterinary issues not shared by other human laboratory departments. Recommendations for all laboratories include use of Class IIA2 biological safety cabinets that are inspected annually; frequent hand washing; use of appropriate disinfectants, including 1:10 dilutions of household bleach; dependence on risk assessments for many activities; development of written safety protocols that address the risks of chemicals in the laboratory; the need for negative airflow into the laboratory; areas of the laboratory in which use of gloves is optional or is recommended; and the national need for a central site for surveillance and nonpunitive reporting of laboratory incidents/exposures, injuries, and infections.

  9. Theoretical and practical considerations for teaching diagnostic electronic-nose technologies to clinical laboratory technicians

    Treesearch

    Alphus D. Wilson

    2012-01-01

    The rapid development of new electronic technologies and instruments, utilized to perform many current clinical operations in the biomedical field, is changing the way medical health care is delivered to patients. The majority of test results from laboratory analyses, performed with these analytical instruments often prior to clinical examinations, are frequently used...

  10. Epidemic outbreaks, diagnostics, and control measures of the H5N1 highly pathogenic avian influenza in the Kingdom of Saudi Arabia, 2007-08.

    PubMed

    Lu, Huaguang; Ismail, Mahmoud Moussa; Khan, Owais Ahmed; Al Hammad, Yousef; Abdel Rhman, Salah Shaban; Al-Blowi, Mohamed Hamad

    2010-03-01

    The first outbreak of H5N1 highly pathogenic avian influenza (HPAI) in the Kingdom of Saudi Arabia (KSA) occurred in two "backyard" flocks of Houbara bustards and falcons in February 2007. Subsequent outbreaks were seen through the end of 2007 in "backyard" birds including native chickens, ostriches, turkeys, ducks, and peacocks. From November 2007 through January 2008, H5N1 HPAI outbreaks occurred in 19 commercial poultry premises, including two broiler breeder farms, one layer breeder farm, one ostrich farm, and 15 commercial layer farms, with approximately 4.75 million birds affected. Laboratory diagnosis of all H5N1-positive cases was conducted at the Central Veterinary Diagnostic Laboratory (CVDL) in Riyadh, Saudi Arabia. A combination of diagnostic tests was used to confirm the laboratory diagnosis. A rapid antigen-capture test and real-time reverse transcriptase-PCR (rtRT-PCR) assay on clinical and field specimens were conducted initially. Meanwhile, virus isolation in specific-pathogen-free embryonating chicken eggs was performed and was followed by hemagglutinin (HA) and hemagglutination inhibition tests, then rapid antigen-capture and rtRT-PCR tests on HA-positive allantoic fluid samples. In most HPAI cases, a complete laboratory diagnosis was made within 24-48 hr at the CVDL. Saudi Arabian government officials made immediate decisions to depopulate all H5N1-affected and nonaffected flocks within a 5-km radius area and applied quarantine zones to prevent the virus from spreading to other areas. Other control measures, such as closure of live bird markets and intensive surveillance tests on all poultry species within quarantine zones, were in place during the outbreaks. As a result, the HPAI outbreaks were quickly controlled, and no positive cases were detected after January 29, 2008. The KSA was declared free of HPAI on April 30, 2008, by the World Animal Health Organization.

  11. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    PubMed

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  12. Benefits and challenges of molecular diagnostics for childhood tuberculosis.

    PubMed

    Gutierrez, Cristina

    2016-12-01

    Expanding tuberculosis (TB)-diagnostic services, including access to rapid tests, is a World Health Organization (WHO) strategy to accelerate progress toward ending TB. Faster and more sensitive molecular tests capable of diagnosing TB and drug-resistant TB have the technical capacity to address limitations associated with smears and cultures by increasing accuracy and shortening turnaround times as compared with those of these conventional laboratory methods. Nucleic acid amplification assays used to detect and analyze Mycobacterium tuberculosis (MTB)-complex nucleic acids can be used directly on specimens from patients suspected of having TB. Recently, several commercial molecular tests were developed to detect MTB and determine the drug resistance (DR) based on detection of specific genetic mutations conferring resistance. The first to be endorsed by the WHO was molecular line-probe assay technology. This test uses polymerase chain reaction (PCR) and reverse-hybridization methods to rapidly identify MTB and DR-related mutations simultaneously. More recently, the WHO endorsed Xpert MTB/RIF, Cepheid Inc, CA, USA, a fully automated assay used for TB diagnosis that relies upon PCR techniques for detection of TB and rifampicin resistance-related mutations. Other promising molecular TB assays for simplifying PCR-based testing protocols and increasing their accuracy are under development and evaluation. Although we lack a practical gold standard for the diagnosis of childhood TB, its bacteriological confirmation is always recommended to be sought whenever possible prior to a diagnostic decision being made. Conventional diagnostic laboratory TB tests are less efficient for children as compared with adults, because sufficient sputum samples are more difficult to collect from infants and young children, and their disease is often paucibacillary, resulting in smear-negative disease. These inherent challenges associated with childhood TB are due to immunological- and pathophysiological-response differences relative to those observed in adults. Several recent meta-analyses showed low sensitivity estimates of PCR-based TB assays for paucibacillary forms of TB (extrapulmonary TB and smear-negative pulmonary disease), which represent the vast majority of childhood TB cases. Despite the lack of evidence regarding use of the rapid molecular assays to identify TB and detect DR in children, and due to the clinical nature of childhood TB, TB-expert groups recommend including rapid methods for TB identification and DR detection in diagnostic algorithms for children suspected of both smear-positive and -negative pulmonary or extrapulmonary TB, both with or without human immunodeficiency virus (HIV)-coinfection, when combined with standard methods (including clinical, microbiological, and radiological assessment) for diagnosing active TB and conventional DR. Since 2011, the WHO has specifically recommended use of the Xpert MTB/RIF test as an initial diagnostic tool for children with suspected HIV-associated TB or multidrug-resistant TB based on successful treatment data related to adults. Implementation of the rapid molecular assays for rapid detection of TB and DR should occur in laboratories with proven capability to run molecular tests and where quality control systems are implemented. Molecular approaches should be more largely tested in children, given their status as the group in whom the diagnostic dilemma is most pronounced. These tests should also be included in specific childhood TB diagnostic algorithms adapted to the local/national context in combination with other strategies for improving diagnostics, including more effective specimen collection. Copyright © 2016.

  13. 21 CFR 660.5 - Specificity.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.5 Specificity. Each filling of the product shall be specific for antibody to hepatitis B surface antigen, as...

  14. 21 CFR 660.5 - Specificity.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.5 Specificity. Each filling of the product shall be specific for antibody to hepatitis B surface antigen, as...

  15. 21 CFR 660.5 - Specificity.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.5 Specificity. Each filling of the product shall be specific for antibody to hepatitis B surface antigen, as...

  16. 21 CFR 660.5 - Specificity.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Antibody to Hepatitis B Surface Antigen § 660.5 Specificity. Each filling of the product shall be specific for antibody to hepatitis B surface antigen, as...

  17. Biosafety principles and practices for the veterinary diagnostic laboratory.

    PubMed

    Kozlovac, Joseph; Schmitt, Beverly

    2015-01-01

    Good biosafety and biocontainment programs and practices are critical components of the successful operation of any veterinary diagnostic laboratory. In this chapter we provide information and guidance on critical biosafety management program elements, facility requirements, protective equipment, and procedures necessary to ensure that the laboratory worker and the environment are adequately protected in the challenging work environment of the veterinary diagnostic laboratory in general and provide specific guidance for those laboratories employing molecular diagnostic techniques.

  18. Molecular methods for somatic mutation testing in lung adenocarcinoma: EGFR and beyond

    PubMed Central

    Rogers, Toni-Maree; Fellowes, Andrew; Bell, Anthony; Fox, Stephen

    2015-01-01

    Somatic mutational profiling in cancer has revolutionized the practice of clinical oncology. The discovery of driver mutations in non-small cell lung cancer (NSCLC) is an example of this. Molecular testing of lung adenocarcinoma is now considered standard of care and part of the diagnostic algorithm. This article provides an overview of the workflow of molecular testing in a clinical diagnostic laboratory discussing in particular novel assays that are currently in use for somatic mutation detection in NSCLC focussing on epidermal growth factor receptor (EGFR) mutations and anaplastic lymphoma kinase (ALK), ROS1 and RET rearrangements. PMID:25870795

  19. Evaluation of a laboratory quality assurance pilot programme for malaria diagnostics in low-transmission areas of Kenya, 2013.

    PubMed

    Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M

    2017-05-25

    One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.

  20. Launching a Laboratory Testing Process Quality Improvement Toolkit: From the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP).

    PubMed

    Fernald, Douglas; Hamer, Mika; James, Kathy; Tutt, Brandon; West, David

    2015-01-01

    Family medicine and internal medicine physicians order diagnostic laboratory tests for nearly one-third of patient encounters in an average week, yet among medical errors in primary care, an estimated 15% to 54% are attributed to laboratory testing processes. From a practice improvement perspective, we (1) describe the need for laboratory testing process quality improvements from the perspective of primary care practices, and (2) describe the approaches and resources needed to implement laboratory testing process quality improvements in practice. We applied practice observations, process mapping, and interviews with primary care practices in the Shared Networks of Colorado Ambulatory Practices and Partners (SNOCAP)-affiliated practice-based research networks that field-tested in 2013 a laboratory testing process improvement toolkit. From the data collected in each of the 22 participating practices, common testing quality issues included, but were not limited to, 3 main testing process steps: laboratory test preparation, test tracking, and patient notification. Three overarching qualitative themes emerged: practices readily acknowledge multiple laboratory testing process problems; practices know that they need help addressing the issues; and practices face challenges with finding patient-centered solutions compatible with practice priorities and available resources. While practices were able to get started with guidance and a toolkit to improve laboratory testing processes, most did not seem able to achieve their quality improvement aims unassisted. Providing specific guidance tools with practice facilitation or other rapid-cycle quality improvement support may be an effective approach to improve common laboratory testing issues in primary care. © Copyright 2015 by the American Board of Family Medicine.

  1. External Quality Assessment for the Detection of Measles Virus by Reverse Transcription-PCR Using Armored RNA

    PubMed Central

    Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming

    2015-01-01

    In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus. PMID:26244795

  2. External Quality Assessment for the Detection of Measles Virus by Reverse Transcription-PCR Using Armored RNA.

    PubMed

    Zhang, Dong; Sun, Yu; Jia, Tingting; Zhang, Lei; Wang, Guojing; Zhang, Rui; Zhang, Kuo; Lin, Guigao; Xie, Jiehong; Wang, Lunan; Li, Jinming

    2015-01-01

    In recent years, nucleic acid tests for detection of measles virus RNA have been widely applied in laboratories belonging to the measles surveillance system of China. An external quality assessment program was established by the National Center for Clinical Laboratories to evaluate the performance of nucleic acid tests for measles virus. The external quality assessment panel, which consisted of 10 specimens, was prepared using armored RNAs, complex of noninfectious MS2 bacteriophage coat proteins encapsulated RNA of measles virus, as measles virus surrogate controls. Conserved sequences amplified from a circulating measles virus strain or from a vaccine strain were encapsulated into these armored RNAs. Forty-one participating laboratories from 15 provinces, municipalities, or autonomous regions that currently conduct molecular detection of measles virus enrolled in the external quality assessment program, including 40 measles surveillance system laboratories and one diagnostic reagent manufacturer. Forty laboratories used commercial reverse transcription-quantitative PCR kits, with only one laboratory applying a conventional PCR method developed in-house. The results indicated that most of the participants (38/41, 92.7%) were able to accurately detect the panel with 100% sensitivity and 100% specificity. Although a wide range of commercially available kits for nucleic acid extraction and reverse transcription polymerase chain reaction were used by the participants, only two false-negative results and one false-positive result were generated; these were generated by three separate laboratories. Both false-negative results were obtained with tests performed on specimens with the lowest concentration (1.2 × 104 genomic equivalents/mL). In addition, all 18 participants from Beijing achieved 100% sensitivity and 100% specificity. Overall, we conclude that the majority of the laboratories evaluated have reliable diagnostic capacities for the detection of measles virus.

  3. Economic evaluation of laboratory testing strategies for hospital-associated Clostridium difficile infection.

    PubMed

    Schroeder, Lee F; Robilotti, Elizabeth; Peterson, Lance R; Banaei, Niaz; Dowdy, David W

    2014-02-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI.

  4. Economic Evaluation of Laboratory Testing Strategies for Hospital-Associated Clostridium difficile Infection

    PubMed Central

    Robilotti, Elizabeth; Peterson, Lance R.; Banaei, Niaz; Dowdy, David W.

    2014-01-01

    Clostridium difficile infection (CDI) is the most common cause of infectious diarrhea in health care settings, and for patients presumed to have CDI, their isolation while awaiting laboratory results is costly. Newer rapid tests for CDI may reduce this burden, but the economic consequences of different testing algorithms remain unexplored. We used decision analysis from the hospital perspective to compare multiple CDI testing algorithms for adult inpatients with suspected CDI, assuming patient management according to laboratory results. CDI testing strategies included combinations of on-demand PCR (odPCR), batch PCR, lateral-flow diagnostics, plate-reader enzyme immunoassay, and direct tissue culture cytotoxicity. In the reference scenario, algorithms incorporating rapid testing were cost-effective relative to nonrapid algorithms. For every 10,000 symptomatic adults, relative to a strategy of treating nobody, lateral-flow glutamate dehydrogenase (GDH)/odPCR generated 831 true-positive results and cost $1,600 per additional true-positive case treated. Stand-alone odPCR was more effective and more expensive, identifying 174 additional true-positive cases at $6,900 per additional case treated. All other testing strategies were dominated by (i.e., more costly and less effective than) stand-alone odPCR or odPCR preceded by lateral-flow screening. A cost-benefit analysis (including estimated costs of missed cases) favored stand-alone odPCR in most settings but favored odPCR preceded by lateral-flow testing if a missed CDI case resulted in less than $5,000 of extended hospital stay costs and <2 transmissions, if lateral-flow GDH diagnostic sensitivity was >93%, or if the symptomatic carrier proportion among the toxigenic culture-positive cases was >80%. These results can aid guideline developers and laboratory directors who are considering rapid testing algorithms for diagnosing CDI. PMID:24478478

  5. Infection with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance--Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2012-2015.

    PubMed

    Huang, Jennifer Y; Henao, Olga L; Griffin, Patricia M; Vugia, Duc J; Cronquist, Alicia B; Hurd, Sharon; Tobin-D'Angelo, Melissa; Ryan, Patricia; Smith, Kirk; Lathrop, Sarah; Zansky, Shelley; Cieslak, Paul R; Dunn, John; Holt, Kristin G; Wolpert, Beverly J; Patrick, Mary E

    2016-04-15

    To evaluate progress toward prevention of enteric and foodborne illnesses in the United States, the Foodborne Diseases Active Surveillance Network (FoodNet) monitors the incidence of laboratory-confirmed infections caused by nine pathogens transmitted commonly through food in 10 U.S. sites. This report summarizes preliminary 2015 data and describes trends since 2012. In 2015, FoodNet reported 20,107 confirmed cases (defined as culture-confirmed bacterial infections and laboratory-confirmed parasitic infections), 4,531 hospitalizations, and 77 deaths. FoodNet also received reports of 3,112 positive culture-independent diagnostic tests (CIDTs) without culture-confirmation, a number that has markedly increased since 2012. Diagnostic testing practices for enteric pathogens are rapidly moving away from culture-based methods. The continued shift from culture-based methods to CIDTs that do not produce the isolates needed to distinguish between strains and subtypes affects the interpretation of public health surveillance data and ability to monitor progress toward prevention efforts. Expanded case definitions and strategies for obtaining bacterial isolates are crucial during this transition period.

  6. The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays.

    PubMed

    Zhan, Li; Guo, Shuang-Zhuang; Song, Fayi; Gong, Yan; Xu, Feng; Boulware, David R; McAlpine, Michael C; Chan, Warren C W; Bischof, John C

    2017-12-13

    Rapid, simple, and cost-effective diagnostics are needed to improve healthcare at the point of care (POC). However, the most widely used POC diagnostic, the lateral flow immunoassay (LFA), is ∼1000-times less sensitive and has a smaller analytical range than laboratory tests, requiring a confirmatory test to establish truly negative results. Here, a rational and systematic strategy is used to design the LFA contrast label (i.e., gold nanoparticles) to improve the analytical sensitivity, analytical detection range, and antigen quantification of LFAs. Specifically, we discovered that the size (30, 60, or 100 nm) of the gold nanoparticles is a main contributor to the LFA analytical performance through both the degree of receptor interaction and the ultimate visual or thermal contrast signals. Using the optimal LFA design, we demonstrated the ability to improve the analytical sensitivity by 256-fold and expand the analytical detection range from 3 log 10 to 6 log 10 for diagnosing patients with inflammatory conditions by measuring C-reactive protein. This work demonstrates that, with appropriate design of the contrast label, a simple and commonly used diagnostic technology can compete with more expensive state-of-the-art laboratory tests.

  7. 78 FR 54487 - Abbott Laboratories; Diagnostic-Hematology; Including On-Site Leased Workers From Manpower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-04

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-82,379] Abbott Laboratories... February 22, 2013, applicable to workers of Abbott Laboratories, Diagnostic--Hematology division, including... Clara, California location of Abbott Laboratories, Diagnostic--Hematology Division. The Department has...

  8. Diagnostic schemes for reducing epidemic size of African viral hemorrhagic fever outbreaks.

    PubMed

    Okeke, Iruka N; Manning, Robert S; Pfeiffer, Thomas

    2014-09-12

    Viral hemorrhagic fever (VHF) outbreaks, with high mortality rates, have often been amplified in African health institutions due to person-to-person transmission via infected body fluids.  By collating and analyzing epidemiological data from documented outbreaks, we observed that diagnostic delay contributes to epidemic size for Ebola and Marburg hemorrhagic fever outbreaks. We used a susceptible-exposed-infectious-removed (SEIR) model and data from the 1995 outbreak in Kikwit, Democratic Republic of Congo, to simulate Ebola hemorrhagic fever epidemics. Our model allows us to describe the dynamics for hospital staff separately from that for the general population, and to implement health worker-specific interventions. The model illustrates that implementing World Health Organization/US Centers for Disease Control and Prevention guidelines of isolating patients who do not respond to antimalarial and antibacterial chemotherapy reduces total outbreak size, from a median of 236, by 90% or more. Routinely employing diagnostic testing in post-mortems of patients that died of refractory fevers reduces the median outbreak size by a further 60%. Even greater reductions in outbreak size were seen when all febrile patients were tested for endemic infections or when febrile health-care workers were tested.  The effect of testing strategies was not impaired by the 1-3 day delay that would occur if testing were performed by a reference laboratory. In addition to improving the quality of care for common causes of febrile infections, increased and strategic use of laboratory diagnostics for fever could reduce the chance of hospital amplification of VHFs in resource-limited African health systems.

  9. Using a CAI Network for Statewide Remediation: GRI in South Carolina.

    ERIC Educational Resources Information Center

    Rumford, John

    1988-01-01

    Describes South Carolina's Governor's Remediation Initiative (GRI), an instructional management system that links diagnostic tests and teaching modules for use by high school mathematics and reading laboratories. (TW)

  10. 21 CFR 660.32 - Collection of source material.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...

  11. 21 CFR 660.32 - Collection of source material.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...

  12. 21 CFR 660.32 - Collection of source material.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...

  13. 21 CFR 660.32 - Collection of source material.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.32 Collection of source material. Blood for Reagent Red Blood Cells from donors of peripheral blood...

  14. Diagnosis of vulvovaginitis: comparison of clinical and microbiological diagnosis.

    PubMed

    Esim Buyukbayrak, Esra; Kars, Bulent; Karsidag, Ayse Yasemin Karageyim; Karadeniz, Bernan Ilkay; Kaymaz, Ozge; Gencer, Serap; Pirimoglu, Zehra Meltem; Unal, Orhan; Turan, Mehmet Cem

    2010-11-01

    The purpose of the present study was to compare the current diagnostic clinical and laboratory approaches to women with vulvovaginal discharge complaint. The secondary outcomes were to determine the prevalence of infections in our setting and to look for the relation between vulvovaginal infections and predisposing factors if present. Premenopausal women applying to our gynecology outpatient clinic with vaginal discharge complaint were enrolled prospectively into the study. Each patient evaluated clinically with direct observation of vaginal secretions, wet mount examination, whiff test, vaginal pH testing and chlamydia rapid antigen test. Each patient also evaluated microbiologically with vaginal discharge culture and gram staining. Clinical diagnosis was compared with the microbiological diagnosis (the gold standard). Diagnostic accuracy was measured with sensitivity, specificity, positive (ppv) and negative predictive values (npv). 460 patients were included in the study. 89.8% of patients received a clinical diagnosis whereas only 36% of them had microbiological diagnosis. The sensitivity, specificity, ppv, npv of clinical diagnosis over microbiological culture results were 95, 13, 38, 82%, respectively. The most commonly encountered microorganisms by culture were Candida species (17.4%) and Gardnerella vaginalis (10.2%). Clinically, the most commonly made diagnoses were mixed infection (34.1%), bacterial vaginosis (32.4%) and fungal infection (14.1%). Symptoms did not predict laboratory results. Predisposing factors (DM, vaginal douching practice, presence of IUD and usage of oral contraceptive pills) were not found to be statistically important influencing factors for vaginal infections. Clinical diagnosis based on combining symptoms with office-based testing improves diagnostic accuracy but is insufficient. The most effective approach also incorporates laboratory testing as an adjunct when a diagnosis is in question or treatment is failing.

  15. Using cytology to increase small animal practice revenue.

    PubMed

    Hodges, Joanne

    2013-11-01

    Diagnostic cytology is a useful, noninvasive test with practical foundations in high-quality medicine and applications to practice building. Cytology will generate practice revenue whether assessed in-house or sent to a clinical pathologist. Thorough in-house evaluation is adequate in some cases, but expert opinion is important in many cases. Specimen slides should at least be reviewed in-house for assessment of cellularity and potential artifacts before submission to a reference laboratory. Reference laboratories also provide special stains and advanced molecular diagnostics to help further characterize many neoplastic processes, search for organisms, identify pigments, and address other important aspects of the lesion. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Present status and perspective of laboratory hematology in Japan: On the standardization of blood cell morphology including myelodysplasia: On behalf of the Japanese Society for Laboratory Hematology.

    PubMed

    Tohyama, K

    2018-05-01

    The Japanese Society for Laboratory Hematology (JSLH) was launched in 2000 and has been developed by a mutual collaboration of hematologists, medical technologists, and the companies involved in hematological laboratory testing. The aim of JSLH is the progress and development of laboratory hematology by academic conferences, periodic publication of academic journal, training and education (in the meeting, the journal, or the website), promotion of the standardization of laboratory hematology, and certification of the laboratory hematology specialists. Among 3 specialized committees organized for the standardization of laboratory hematology, the standardization committee on blood cell morphology has been dealing with the various projects on peripheral/bone marrow blood cells and normal/abnormal morphology. Another independent organization, the Japanese National Research Group on idiopathic bone marrow failure syndromes (BMF), has raised the importance of the dysplasia of myelodysplastic syndromes (MDS) and has been conducting the prospective registration, central review, and follow-up study of MDS. This group recently proposed the grading system for diagnostic accuracy of MDS, and the detailed procedure of morphological diagnosis of MDS is presented in the specialized color atlas with typical photographs of various dysplasia. JSLH has also approved the grading system for diagnostic accuracy of MDS and adopted this standardized diagnostic system to the educational item for certification of the laboratory hematology specialists, aiming at a nationwidely expanding morphological evaluation of myelodysplasia. Further and significant progress in the standardization of blood cell morphology will be expected in Japan through the activity of JSLH. © 2018 John Wiley & Sons Ltd.

  17. A Structural Health Monitoring Software Tool for Optimization, Diagnostics and Prognostics

    DTIC Science & Technology

    2011-01-01

    A Structural Health Monitoring Software Tool for Optimization, Diagnostics and Prognostics Seth S . Kessler1, Eric B. Flynn2, Christopher T...technology more accessible, and commercially practical. 1. INTRODUCTION Currently successful laboratory non- destructive testing and monitoring...PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES

  18. Biomarker Discovery in Gulf War Veterans: Development of a War Illness Diagnostic Panel

    DTIC Science & Technology

    2016-12-01

    with GWI reflect a persistent disruption in central nervous system (CNS) proinflammatory and neuroendocrine parameters. These processes can...differences in these systems are more subtle than the frank “abnormalities” identified with standard diagnostic tests (e.g., measures indicating...the coagulation system in Gulf War Illness: a potential pathophysiologic link with chronic fatigue syndrome. A laboratory approach to diagnosis. Blood

  19. Central nervous system Aspergillus infection after epidural analgesia: diagnosis, therapeutic challenges, and literature review

    PubMed Central

    Genzen, Jonathan R.; Kenney, Barton

    2009-01-01

    Aspergillus terreus was identified in an intra-dural spinal biopsy specimen from an African female with recurrent headache and hydrocephalus. Prior laboratory testing of cerebrospinal fluid (CSF) was non-diagnostic, despite extensive central nervous system (CNS) involvement. CNS Aspergillus infection presents a diagnostic and therapeutic challenge and is reviewed in the context of this particularly instructive and difficult case. PMID:19717262

  20. Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcome.

    PubMed

    Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola

    2016-08-01

    In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  1. 21 CFR 660.31 - Suitability of the donor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...

  2. 21 CFR 660.31 - Suitability of the donor.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...

  3. 21 CFR 660.31 - Suitability of the donor.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...

  4. 21 CFR 660.31 - Suitability of the donor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) BIOLOGICS ADDITIONAL STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.31 Suitability of the donor. Donors of peripheral blood for Reagent Red Blood Cells shall meet the...

  5. [Detecting the markers of HIV infection with the new enzyme immunoassay diagnostic kit "DS-EIA-HIV-AB-AG-SPECTRUM" at the laboratories of AIDS prevention and control centers in the Volga Federal District].

    PubMed

    Ivanova, N I; Peksheva, O Iu

    2009-03-01

    A possibility of simultaneously detecting specific antibodies to HIV-1 and HIV-2 by enzyme immunoassay (EIA) at lower concentrations than those by immunoblotting (IB), and well as an additional possibility of earlier diagnosis of HIV infection, by identifying the HIV-1 antigen p24 lay the foundation of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system made by OOO "Research-and-Production Association "Diagnosticheskiye Sistemy" (Diagnostic Systems). These peculiarities were compared with those of IB at a number of laboratories of AIDS prevention and control centers in the Volga Federal District, by using native serum/plasma samples and a specially designed control panel. The analysis of the conducted studies to identify HIV-1 and HIV-2 antibodies and HIV-1 antigen p24 in 65 plasma/serum samples in the "DS-EIA-HIV-AB-AG-SPECTRUM" and "LIA-HIV-1/2" (OOO "Niarmedik plus") test systems while confirming the positive result indicated agreement in 57 (87.7%) cases. The diagnostic possibilities of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system versus the "New Lav-Blot I" one to make a laboratory diagnosis of HIV infection were studied. Irrefragable answers as to the availability of HIV-1 markers in the study serum samples on the enciphered panel were provided by IB in 73.3% of cases and EIA in 92%.

  6. Clostridium botulinum and the clinical laboratorian: a detailed review of botulism, including biological warfare ramifications of botulinum toxin.

    PubMed

    Caya, James G; Agni, Rashmi; Miller, Joan E

    2004-06-01

    This review article is designed to thoroughly familiarize all health care professionals with the history, classification, epidemiology, clinical characteristics, differential diagnosis, diagnostic evaluation (including laboratory-based testing), treatment, and prognosis of botulism. It is especially targeted toward clinical laboratorians and includes a detailed enumeration of the important clinical laboratory contributions to the diagnosis, treatment, and monitoring of patients with botulism. Finally, the bioterrorism potential for botulism is discussed, with an emphasis on the clinical laboratory ramifications of this possibility. Included medical periodicals and textbooks accessioned from computerized and manual medical literature searches. More than 1000 medical works published from the 1800s through 2003 were retrieved and reviewed in this process. Pertinent data are presented in textual and tabular formats, the latter including 6 tables presenting detailed information regarding the clinical parameters, differential diagnosis, diagnostic studies, laboratory testing, and therapeutic approaches to botulism. Because botulism is such a rare disease, a keen awareness of its manifestations and prompt diagnosis are absolutely crucial for its successful treatment. The bioterrorism potential of botulism adds further urgency to the need for all health care professionals to be familiar with this disease, its proper evaluation, and timely treatment; the need for such urgency clearly includes the clinical laboratory.

  7. 77 FR 4368 - Abbott Laboratories, Diagnostics Division, Including On-Site Leased Workers From Manpower...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-27

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-75,201] Abbott Laboratories..., applicable to workers of Abbott Laboratories, Diagnostics Division, including on-site leased workers from... (clerical) were employed on-site at the Irving, Texas location of Abbott Laboratories, Diagnostics Division...

  8. Specialized sperm function tests in varicocele and the future of andrology laboratory

    PubMed Central

    Majzoub, Ahmad; Esteves, Sandro C; Gosálvez, Jaime; Agarwal, Ashok

    2016-01-01

    Varicocele is a common medical condition entangled with many controversies. Though it is highly prevalent in men with infertility, still it marks its presence in males who do have normal fertility. Determining which patients are negatively affected by varicocele would enable clinicians to better select those men who benefitted the most from surgery. Since conventional semen analysis has been limited in its ability to evaluate the negative effects of varicocele on fertility, a multitude of specialized laboratory tests have emerged. In this review, we examine the role and significance of specialized sperm function tests with regards to varicocele. Among the various tests, analysis of sperm DNA fragmentation and measurements of oxidative stress markers provide an independent measure of fertility in men with varicocele. These diagnostic modalities have both diagnostic and prognostic information complementary to, but distinct from conventional sperm parameters. Test results can guide management and aid in monitoring intervention outcomes. Proteomics, metabolomics, and genomics are areas; though still developing, holding promise to revolutionize our understanding of reproductive physiology, including varicocele. PMID:26780873

  9. MALDI-TOF mass spectrometry and high-consequence bacteria: safety and stability of biothreat bacterial sample testing in clinical diagnostic laboratories.

    PubMed

    Tracz, Dobryan M; Tober, Ashley D; Antonation, Kym S; Corbett, Cindi R

    2018-03-01

    We considered the application of MALDI-TOF mass spectrometry for BSL-3 bacterial diagnostics, with a focus on the biosafety of live-culture direct-colony testing and the stability of stored extracts. Biosafety level 2 (BSL-2) bacterial species were used as surrogates for BSL-3 high-consequence pathogens in all live-culture MALDI-TOF experiments. Viable BSL-2 bacteria were isolated from MALDI-TOF mass spectrometry target plates after 'direct-colony' and 'on-plate' extraction testing, suggesting that the matrix chemicals alone cannot be considered sufficient to inactivate bacterial culture and spores in all samples. Sampling of the instrument interior after direct-colony analysis did not recover viable organisms, suggesting that any potential risks to the laboratory technician are associated with preparation of the MALDI-TOF target plate before or after testing. Secondly, a long-term stability study (3 years) of stored MALDI-TOF extracts showed that match scores can decrease below the threshold for reliable species identification (<1.7), which has implications for proficiency test panel item storage and distribution.

  10. 'Multiple-test' approach to the laboratory diagnosis of tuberculosis -perception of medical doctors from Ujjain, India.

    PubMed

    Purohit, Manju Raj; Sharma, Megha; Rosales-Klintz, Senia; Lundborg, Cecilia Stålsby

    2015-08-11

    Delay in diagnosis is one of the most important factors for the control of tuberculosis (TB) in endemic countries like India. As laboratory diagnosis is the mainstay for identification of active disease, we aim to explore and understand the opinions of medical doctors about the laboratory diagnosis of TB in Ujjain, India. Sixteen qualified specialist medical doctors from Ujjain were purposefully selected for the study. Individual interviews with the doctors (13 men and 3 women), were conducted. As one interview could not be completed, data from 15 interviews were analyzed using manifest and latent content analysis. Based on perception of the doctors, the theme; 'challenges and need for the laboratory diagnosis of TB' emerged from the following subthemes: (i) Relationship between basic element of the TB diseases process such as 'Symptoms prior to diagnoses' and 'Clinical characteristics of TB', which were not specific enough to diagnose TB (ii) The prevailing conditions such as lack of explicit diagnostic tools, lead to the doctors using the 'multiple tests' or 'empiric treatment' approach (iii) The doctors proposed that there is a need for access to a rapid, single and simple diagnostic test, and a need for awareness and knowledge of the practitioners regarding specific TB investigations, and early referral to improve the situation at resource-limited settings. The medical specialists use a 'multiple test' or 'empiric treatment' approach to diagnose TB. According to the participants, there is a low dependence and uptake of the available laboratory TB investigations by medical practitioners. There is an urgent need to have a specific, simple and reliable test, and a protocol, to improve diagnosis of TB and to prevent development of resistant TB.

  11. Interlaboratory and between-specimen comparisons of diagnostic tests for leptospirosis in sheep and cattle.

    PubMed

    Fang, Fang; Collins-Emerson, Julie M; Heuer, Cord; Hill, Fraser I; Tisdall, David J; Wilson, Peter R; Benschop, Jackie

    2014-11-01

    A study was performed to investigate interlaboratory test agreement between a research and a commercial veterinary diagnostic laboratory on blood and urine samples, and to investigate test agreement between blood, urine, and kidney samples (research laboratory) for leptospirosis diagnosis. Samples were sourced from 399 sheep and 146 beef cattle from a local abattoir. Interlaboratory agreement for real-time quantitative polymerase chain reaction (qPCR) results on urine samples was almost perfect (kappa = 0.90), despite the use of different amplification targets (DNA gyrase subunit B gene vs. 16s ribosomal RNA gene), chemistries (SYTO9 vs. TaqMan probe), and pre-PCR processing. Interlaboratory agreement for microscopic agglutination test (MAT) positivity was almost perfect (kappa = 0.93) for Leptospira borgpetersenii serovar Hardjo subtype Hardjobovis (Hardjobovis) but moderate (kappa = 0.53) for Leptospira interrogans serovar Pomona (Pomona). Among animals that had different titers recorded, higher Hardjobovis and lower Pomona titers were reported by the commercial laboratory than by the research laboratory (P < 0.005). These interlaboratory comparisons can assist researchers and diagnosticians in interpreting the sometimes discrepant test results. Within the research laboratory, the comparison of qPCR results on urine and kidney showed almost perfect agreement (kappa = 0.84), suggesting that the qPCR on these 2 specimens can be used interchangeably. The agreement between MAT positivity and urine and kidney qPCR results was fair (kappa = 0.32 and kappa = 0.33, respectively). However, the prevalence ratio of urine and kidney qPCR positivity in Hardjobovis-seropositive versus Hardjobovis-seronegative sheep indicated that Hardjobovis seropositivity found in sheep may be able to predict shedding or renal carriage. © 2014 The Author(s).

  12. A modified Elek test for detection of toxigenic corynebacteria in the diagnostic laboratory.

    PubMed

    Engler, K H; Glushkevich, T; Mazurova, I K; George, R C; Efstratiou, A

    1997-02-01

    The detection of toxigenicity among Corynebacterium diphtheriae and Corynebacterium ulcerans strains is the most important test for the microbiological diagnosis of diphtheria. Difficulties with current methods, in particular the Elek test, are well documented. We therefore describe a modified Elek test which provides an accurate result after only 16 h of incubation, in contrast to 48 h for the conventional test.

  13. Food Microbiology--Design and Testing of a Virtual Laboratory Exercise

    ERIC Educational Resources Information Center

    Flint, Steve; Stewart, Terry

    2010-01-01

    A web-based virtual laboratory exercise in identifying an unknown microorganism was designed for use with a cohort of 3rd-year university food-technology students. They were presented with a food-contamination case, and then walked through a number of diagnostic steps to identify the microorganism. At each step, the students were asked to select 1…

  14. A real-time PCR diagnostic method for detection of Naegleria fowleri.

    PubMed

    Madarová, Lucia; Trnková, Katarína; Feiková, Sona; Klement, Cyril; Obernauerová, Margita

    2010-09-01

    Naegleria fowleri is a free-living amoeba that can cause primary amoebic meningoencephalitis (PAM). While, traditional methods for diagnosing PAM still rely on culture, more current laboratory diagnoses exist based on conventional PCR methods; however, only a few real-time PCR processes have been described as yet. Here, we describe a real-time PCR-based diagnostic method using hybridization fluorescent labelled probes, with a LightCycler instrument and accompanying software (Roche), targeting the Naegleria fowleriMp2Cl5 gene sequence. Using this method, no cross reactivity with other tested epidemiologically relevant prokaryotic and eukaryotic organisms was found. The reaction detection limit was 1 copy of the Mp2Cl5 DNA sequence. This assay could become useful in the rapid laboratory diagnostic assessment of the presence or absence of Naegleria fowleri. Copyright 2009 Elsevier Inc. All rights reserved.

  15. 76 FR 39110 - Medicare Program; Section 3113: The Treatment of Certain Complex Diagnostic Laboratory Tests...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-05

    ... access to care, quality of care, health outcomes, and expenditures. DATES: Supporting information to... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services [CMS-5058-N... Tests Demonstration. The Demonstration is mandated by section 3113 of the Affordable Care Act. This...

  16. Students as Technicians: Screening Newborns for Cystic Fibrosis

    ERIC Educational Resources Information Center

    Gusky, Sharon

    2014-01-01

    In this activity, freshman college students learn biotechnology techniques while playing the role of a laboratory technician. They perform simulations of three diagnostic tests used to screen newborns for cystic fibrosis. By performing an ELISA, a PCR analysis, and a conductivity test, students learn how biotechnology techniques can be used to…

  17. 21 CFR 660.28 - Labeling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.28 Labeling. In... white, except that all or a portion of the final container label of the following Blood Grouping... panel. Blood grouping reagent Color of label paper Anti-A Blue. Anti-B Yellow. Slide and rapid tube test...

  18. 21 CFR 660.28 - Labeling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.28 Labeling. In... white, except that all or a portion of the final container label of the following Blood Grouping... panel. Blood grouping reagent Color of label paper Anti-A Blue. Anti-B Yellow. Slide and rapid tube test...

  19. 21 CFR 660.28 - Labeling.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.28 Labeling. In... white, except that all or a portion of the final container label of the following Blood Grouping... panel. Blood grouping reagent Color of label paper Anti-A Blue. Anti-B Yellow. Slide and rapid tube test...

  20. 21 CFR 660.28 - Labeling.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Blood Grouping Reagent § 660.28 Labeling. In... white, except that all or a portion of the final container label of the following Blood Grouping... panel. Blood grouping reagent Color of label paper Anti-A Blue. Anti-B Yellow. Slide and rapid tube test...

  1. Assessment of Diverse Biological Indicators in Gulf War Illness: Are They Replicable Are They Related

    DTIC Science & Technology

    2016-04-01

    compared to 50 healthy veteran controls in a protocol that includes physical and neuropsychological evaluations, neuroimaging (MRI, fMRI, DTI), adrenal...SUBJECT TERMS Gulf War illness, neuroimaging, neuropsychological testing, immune function, hypothalamic-pituitary-adrenal testing 16. SECURITY... neuropsychological evaluations, assessment of hypothalamic-pituitary-adrenal function, standard clinical diagnostic laboratory tests, and research

  2. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IN VITRO DIAGNOSTIC PRODUCTS FOR HUMAN USE Requirements for Manufacturers and Producers § 809.40... set forth in this section. (b) Sample testing shall be performed in a laboratory using screening tests...

  3. 21 CFR 809.40 - Restrictions on the sale, distribution, and use of OTC test sample collection systems for drugs...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IN VITRO DIAGNOSTIC PRODUCTS FOR HUMAN USE Requirements for Manufacturers and Producers § 809.40... set forth in this section. (b) Sample testing shall be performed in a laboratory using screening tests...

  4. [Building and implementation of management system in laboratories of the National Institute of Hygiene].

    PubMed

    Rozbicka, Beata; Brulińska-Ostrowska, Elzbieta

    2008-01-01

    The rules of good laboratory practice have always been observed in the laboratories of National Institute of Hygiene (NIH) and the reliability of the results has been carefully cared after when performing tests for clients. In 2003 the laboratories performing analyses related to food safety were designated as the national reference laboratories. This, added to the necessity of compliance with work standards and requirements of EU legislation and to the need of confirmation of competence by an independent organisation, led to a decision to seek accreditation of Polish Centre of Accreditation (PCA). The following stages of building and implementation of management system were presented: training, modifications of Institute's organisational structure, elaboration of management system's documentation, renovation and refurbishment of laboratory facilities, implementation of measuring and test equipment's supervision, internal audits and management review. The importance of earlier experiences and achievements with regard to validation of analytical methods and guarding of the quality of the results through organisation and participation in proficiency tests was highlighted. Current status of accreditation of testing procedures used in NIH laboratories that perform analyses in the field of chemistry, microbiology, radiobiology and medical diagnostic tests was presented.

  5. miRNA assays in the clinical laboratory: workflow, detection technologies and automation aspects.

    PubMed

    Kappel, Andreas; Keller, Andreas

    2017-05-01

    microRNAs (miRNAs) are short non-coding RNA molecules that regulate gene expression in eukaryotes. Their differential abundance is indicative or even causative for a variety of pathological processes including cancer or cardiovascular disorders. Due to their important biological function, miRNAs represent a promising class of novel biomarkers that may be used to diagnose life-threatening diseases, and to monitor disease progression. Further, they may guide treatment selection or dosage of drugs. miRNAs from blood or derived fractions are particularly interesting candidates for routine laboratory applications, as they can be measured in most clinical laboratories already today. This assures a good accessibility of respective tests. Albeit their great potential, miRNA-based diagnostic tests have not made their way yet into the clinical routine, and hence no standardized workflows have been established to measure miRNAs for patients' benefit. In this review we summarize the detection technologies and workflow options that exist to measure miRNAs, and we describe the advantages and disadvantages of each of these options. Moreover, we also provide a perspective on data analysis aspects that are vital for translation of raw data into actionable diagnostic test results.

  6. Commercial Molecular Tests for Fungal Diagnosis from a Practical Point of View.

    PubMed

    Lackner, Michaela; Lass-Flörl, Cornelia

    2017-01-01

    The increasing interest in molecular diagnostics is a result of tremendously improved knowledge on fungal infections in the past 20 years and the rapid development of new methods, in particular polymerase chain reaction. High expectations have been placed on molecular diagnostics, and the number of laboratories now using the relevant technology is rapidly increasing-resulting in an obvious need for standardization and definition of laboratory organization. In the past 10 years, multiple new molecular tools were marketed for the detection of DNA, antibodies, cell wall components, or other antigens. In contrast to classical culture methods, molecular methods do not detect a viable organisms, but only molecules which indicate its presence; this can be nucleic acids, cell components (antigens), or antibodies (Fig. 1). In this chapter, an overview is provided on commercially available detection tools, their strength and how to use them. A main focus is laid on providing tips and tricks that make daily life easier. We try to focus and mention methodical details which are not highlighted in the manufacturer's instructions of these test kits, but are based on our personal experience in the laboratory. Important to keep in mind is that molecular tools cannot replace culture, microscopy, or a critical view on patients' clinical history, signs, and symptoms, but provide a valuable add on tool. Diagnosis should not be based solely on a molecular test, but molecular tools might deliver an important piece of information that helps matching the diagnostic puzzle to a diagnosis, in particular as few tests are in vitro diagnostic tests (IVD) or only part of the whole test carries the IVD certificate (e.g., DNA extraction is often not included). Please be aware that the authors do not claim to provide a complete overview on all commercially available diagnostic assays being currently marketed for fungal detection, as those are subject to constant change. A main focus is put on commonly used panfungal assays and pathogen-specific assays, including Aspergillus-specific, Candida-specific, Cryptococcus specific, Histoplasma-specific, and Pneumocystis-specific assays. Assays are categorized according to their underlying principle in either antigen-detecting or antibody-detecting or DNA-detecting (Fig. 1). Other non-DNA-detecting nucleic acid methods such as FISH and PNA FISH are not summarized in this chapter and an overview on test performance, common false positives, and the clinical evaluation of commercial tests in studies is provided already in a previous book series by Javier Yugueros Marcos and David H. Pincus (Marcos and Pincus, Methods Mol Biol 968:25-54, 2013).

  7. Microfluidic technology for molecular diagnostics.

    PubMed

    Robinson, Tom; Dittrich, Petra S

    2013-01-01

    Molecular diagnostics have helped to improve the lives of millions of patients worldwide by allowing clinicians to diagnose patients earlier as well as providing better ongoing therapies. Point-of-care (POC) testing can bring these laboratory-based techniques to the patient in a home setting or to remote settings in the developing world. However, despite substantial progress in the field, there still remain many challenges. Progress in molecular diagnostics has benefitted greatly from microfluidic technology. This chapter aims to summarise the more recent advances in microfluidic-based molecular diagnostics. Sections include an introduction to microfluidic technology, the challenges of molecular diagnostics, how microfluidic advances are working to solve these issues, some alternative design approaches, and detection within these systems.

  8. Automation, consolidation, and integration in autoimmune diagnostics.

    PubMed

    Tozzoli, Renato; D'Aurizio, Federica; Villalta, Danilo; Bizzaro, Nicola

    2015-08-01

    Over the past two decades, we have witnessed an extraordinary change in autoimmune diagnostics, characterized by the progressive evolution of analytical technologies, the availability of new tests, and the explosive growth of molecular biology and proteomics. Aside from these huge improvements, organizational changes have also occurred which brought about a more modern vision of the autoimmune laboratory. The introduction of automation (for harmonization of testing, reduction of human error, reduction of handling steps, increase of productivity, decrease of turnaround time, improvement of safety), consolidation (combining different analytical technologies or strategies on one instrument or on one group of connected instruments) and integration (linking analytical instruments or group of instruments with pre- and post-analytical devices) opened a new era in immunodiagnostics. In this article, we review the most important changes that have occurred in autoimmune diagnostics and present some models related to the introduction of automation in the autoimmunology laboratory, such as automated indirect immunofluorescence and changes in the two-step strategy for detection of autoantibodies; automated monoplex immunoassays and reduction of turnaround time; and automated multiplex immunoassays for autoantibody profiling.

  9. Recent Progress in the Development of Diagnostic Tests for Malaria.

    PubMed

    Krampa, Francis D; Aniweh, Yaw; Awandare, Gordon A; Kanyong, Prosper

    2017-09-19

    The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the need for accurate diagnosis of malaria due to the continuous increase in the cost of medication, and the emergence and spread of drug resistant strains. However, the widely utilized Giemsa-stained microscopy and immunochromatographic tests for malaria are liable to several drawbacks, including inadequate sensitivity and false-positive outcomes. Alternative methods that offer improvements in performance are either expensive, have longer turnaround time or require a level of expertise that makes them unsuitable for point-of-care (POC) applications. These gaps necessitate exploration of more efficient detection techniques with the potential of POC applications, especially in resource-limited settings. This minireview discusses some of the recent trends and new approaches that are seeking to improve the clinical diagnosis of malaria.

  10. [The quality management in clinical diagnostic laboratory in conditions of the Federal Center of traumatology, orthopedics and endoprosthesis replacement of Minzdrav of Russia (Cheboksary)].

    PubMed

    Nikolaev, N S; Nazarova, V V; Dobrovol'skaia, N Iu; Orlova, A V; Pchelova, N N

    2014-10-01

    The article presents experience of clinical diagnostic laboratory of the Federal Center of traumatology, orthopedics and endoprosthesis replacement of Minzdrav of Russia (Cheboksary) in the area of quality management of medical laboratory services on the basis of evaluation of efficacy and effectiveness of processes. The factors effecting quality of functioning of clinical diagnostic laboratory are indicated. The criteria and indicators of efficacy of work of employees of clinical diagnostic laboratory are presented.

  11. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  12. Rubella Surveillance and Diagnostic Testing among a Low-Prevalence Population, New York City, 2012–2013

    PubMed Central

    Zucker, Jane R.; Giancotti, Francesca R.; Abernathy, Emily; Icenogle, Joseph; Rakeman, Jennifer L.; Rosen, Jennifer B.

    2017-01-01

    ABSTRACT The New York City Department of Health and Mental Hygiene (DOHMH) receives clinical and laboratory reports for rubella. Because rubella immunoglobulin M (IgM) assays may produce false-positive results and rubella infections may be asymptomatic, interpretation of positive IgM results can be challenging. Rubella reports received by DOHMH in 2012 to 2013 were reviewed. The rubella IgM testing purpose was determined through case investigation. Results of IgM testing by indirect enzyme-linked immunosorbent assay (ELISA) and capture enzyme immunoassay (EIA) were compared to determine positive predictive value (PPV) and specificity. DOHMH received 199 rubella reports; 2 were true cases. Of all reports, 77.9% were tested for rubella IgM erroneously, 19.6% were tested for diagnostic purposes, 2.0% had unknown test purpose, and 0.5% were not tested. PPV of indirect ELISA was 6% overall, 14% for diagnostic tests, and 0% for tests ordered erroneously. PPV of capture EIA was 29% overall, 50% for diagnostic tests, and 0% for tests ordered erroneously. Overall, specificity was 52% for indirect ELISA and 85% for capture EIA. Limiting rubella IgM testing to patients for whom rubella diagnosis is suspected and using a more specific IgM assay have the potential to reduce false-positive rubella IgM results. PMID:28701468

  13. Current and Projected Modes of Delivery of Veterinary Medical Services to Animal Agriculture: Diagnostic Laboratory Services.

    ERIC Educational Resources Information Center

    Seaton, Vaughn A.

    1980-01-01

    The veterinary diagnostic laboratory's prime role has been diagnosis and/or laboratory findings to assist a diagnosis. Interpretation and evaluation and more involvement with decision-making in monitoring groups of animals and their health status are seen as future roles for diagnostic laboratories. (MLW)

  14. Computerized provider order entry in the clinical laboratory

    PubMed Central

    Baron, Jason M.; Dighe, Anand S.

    2011-01-01

    Clinicians have traditionally ordered laboratory tests using paper-based orders and requisitions. However, paper orders are becoming increasingly incompatible with the complexities, challenges, and resource constraints of our modern healthcare systems and are being replaced by electronic order entry systems. Electronic systems that allow direct provider input of diagnostic testing or medication orders into a computer system are known as Computerized Provider Order Entry (CPOE) systems. Adoption of laboratory CPOE systems may offer institutions many benefits, including reduced test turnaround time, improved test utilization, and better adherence to practice guidelines. In this review, we outline the functionality of various CPOE implementations, review the reported benefits, and discuss strategies for using CPOE to improve the test ordering process. Further, we discuss barriers to the implementation of CPOE systems that have prevented their more widespread adoption. PMID:21886891

  15. Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine: Part 4: Tissue Tools for Quality Assurance in Immunohistochemistry.

    PubMed

    Cheung, Carol C; D'Arrigo, Corrado; Dietel, Manfred; Francis, Glenn D; Fulton, Regan; Gilks, C Blake; Hall, Jacqueline A; Hornick, Jason L; Ibrahim, Merdol; Marchetti, Antonio; Miller, Keith; van Krieken, J Han; Nielsen, Soren; Swanson, Paul E; Taylor, Clive R; Vyberg, Mogens; Zhou, Xiaoge; Torlakovic, Emina E

    2017-04-01

    The numbers of diagnostic, prognostic, and predictive immunohistochemistry (IHC) tests are increasing; the implementation and validation of new IHC tests, revalidation of existing tests, as well as the on-going need for daily quality assurance monitoring present significant challenges to clinical laboratories. There is a need for proper quality tools, specifically tissue tools that will enable laboratories to successfully carry out these processes. This paper clarifies, through the lens of laboratory tissue tools, how validation, verification, and revalidation of IHC tests can be performed in order to develop and maintain high quality "fit-for-purpose" IHC testing in the era of precision medicine. This is the final part of the 4-part series "Evolution of Quality Assurance for Clinical Immunohistochemistry in the Era of Precision Medicine."

  16. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.

  17. [Peculiarities of the early diagnostics of malignant nasopharyngal neoplasms].

    PubMed

    Baryshev, V V; Andreev, V G; Sevryukov, F E; Buyakova, M E; Akki, E D

    The authors consider the risk factors and the specific clinical symptoms of the malignant nasopharyngal neoplasms as well as the methods for instrumental, laboratory, and pathomorphological diagnostics of this pathology. The full scale implementation of the recommendations for the timely detection of the tumours using the aforementioned diagnostic procedures and tests makes it possible to reduce to a minimum the interval between the establishment of the diagnosis and the onset of the relevant treatment at the early stages of the disease and thereby to ensure the improvement of its long-term outcomes.

  18. Diagnostic sampling and gross pathology of New World camelids.

    PubMed

    Bildfell, Robert J; Löhr, Christiane V; Tornquist, Susan J

    2012-11-01

    This article provides an overview of tests and appropriate samples to send to a Veterinary Diagnostic Laboratory for the diagnosis of common diseases of New World Camelids (NWC) such as abortions, congenital anomalies, anemia, enteritis, endoparasitism, gastric ulcer, hepatic lipidosis, encephalitis, pneumonia, dermatosis, neoplasia and cryptococcosis. Unique anatomic features of NWC and common findings encountered during gross necropsy examination are briefly reviewed. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. Implications of the introduction of laboratory demand management at primary care clinics in South Africa on laboratory expenditure

    PubMed Central

    Lekalakala, Ruth; Asmall, Shaidah; Cassim, Naseem

    2016-01-01

    Background Diagnostic health laboratory services are regarded as an integral part of the national health infrastructure across all countries. Clinical laboratory tests contribute substantially to health system goals of increasing quality of care and improving patient outcomes. Objectives This study aimed to analyse current laboratory expenditures at the primary healthcare (PHC) level in South Africa as processed by the National Health Laboratory Service and to determine the potential cost savings of introducing laboratory demand management. Methods A retrospective cross-sectional analysis of laboratory expenditures for the 2013/2014 financial year across 11 pilot National Health Insurance health districts was conducted. Laboratory expenditure tariff codes were cross-tabulated to the PHC essential laboratory tests list (ELL) to determine inappropriate testing. Data were analysed using a Microsoft Access database and Excel software. Results Approximately R35 million South African Rand (10%) of the estimated R339 million in expenditures was for tests that were not listed within the ELL. Approximately 47% of expenditure was for laboratory tests that were indicated in the algorithmic management of patients on antiretroviral treatment. The other main cost drivers for non-ELL testing included full blood count and urea, as well as electrolyte profiles usually requested to support management of patients on antiretroviral treatment. Conclusions Considerable annual savings of up to 10% in laboratory expenditure are possible at the PHC level by implementing laboratory demand management. In addition, to achieve these savings, a standardised PHC laboratory request form and some form of electronic gatekeeping system that must be supported by an educational component should be implemented. PMID:28879107

  20. ROC curves in clinical chemistry: uses, misuses, and possible solutions.

    PubMed

    Obuchowski, Nancy A; Lieber, Michael L; Wians, Frank H

    2004-07-01

    ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas >/=0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.

  1. Rapid molecular diagnostics for multi-drug resistant tuberculosis in India.

    PubMed

    Ramachandran, Rajeswari; Muniyandi, M

    2018-03-01

    Rapid molecular diagnostic methods help in the detection of TB and Rifampicin resistance. These methods detect TB early, are accurate and play a crucial role in reducing the burden of drug resistant tuberculosis. Areas covered: This review analyses rapid molecular diagnostic tools used in the diagnosis of MDR-TB in India, such as the Line Probe Assay and GeneXpert. We have discussed the burden of MDR-TB and the impact of recent diagnostic tools on case detection and treatment outcomes. This review also discusses the costs involved in establishing these new techniques in India. Expert commentary: Molecular methods have considerable advantages for the programmatic management of drug resistant TB. These include speed, standardization of testing, potentially high throughput and reduced laboratory biosafety requirements. There is a desperate need for India to adopt modern, rapid, molecular tools with point-of-care tests being currently evaluated. New molecular diagnostic tests appear to be cost effective and also help in detecting missing cases. There is enough evidence to support the scaling up of these new tools in India.

  2. Mobile device for disease diagnosis and data tracking in resource-limited settings.

    PubMed

    Chin, Curtis D; Cheung, Yuk Kee; Laksanasopin, Tassaneewan; Modena, Mario M; Chin, Sau Yin; Sridhara, Archana A; Steinmiller, David; Linder, Vincent; Mushingantahe, Jules; Umviligihozo, Gisele; Karita, Etienne; Mwambarangwe, Lambert; Braunstein, Sarah L; van de Wijgert, Janneke; Sahabo, Ruben; Justman, Jessica E; El-Sadr, Wafaa; Sia, Samuel K

    2013-04-01

    Collection of epidemiological data and care of patients are hampered by lack of access to laboratory diagnostic equipment and patients' health records in resource-limited settings. We engineered a low-cost mobile device that combines cell-phone and satellite communication technologies with fluid miniaturization techniques for performing all essential ELISA functions. We assessed the device's ability to perform HIV serodiagnostic testing in Rwanda and synchronize results in real time with electronic health records. We tested serum, plasma, and whole blood samples collected in Rwanda and on a commercially available sample panel made of mixed antibody titers. HIV testing on 167 Rwandan patients evaluated for HIV, viral hepatitis, and sexually transmitted infections yielded diagnostic sensitivity and specificity of 100% and 99%, respectively. Testing on 40 Rwandan whole-blood samples-using 1 μL of sample per patient-resulted in diagnostic sensitivity and specificity of 100% and 100%. The mobile device also successfully transmitted all whole-blood test results from a Rwandan clinic to a medical records database stored on the cloud. For all samples in the commercial panel, the device produced results in agreement with a leading ELISA test, including detection of weakly positive samples that were missed by existing rapid tests. The device operated autonomously with minimal user input, produced each result 10 times faster than benchtop ELISA, and consumed as little power as a mobile phone. A low-cost mobile device can perform a blood-based HIV serodiagnostic test with laboratory-level accuracy and real-time synchronization of patient health record data. © 2012 American Association for Clinical Chemistry

  3. Application of Immunohistochemistry and Molecular Diagnostics to Clinically Relevant Problems in Endometrial Cancer Bojana Djordjevic, Shannon Westin, Russell R. Broaddus

    PubMed Central

    Djordjevic, Bojana; Westin, Shannon; Broaddus, Russell R.

    2012-01-01

    Synopsis A number of different clinical scenarios are presented in which lab-based analyses beyond the usual diagnosis based on light microscopic examination of H&E stained slides – immunohistochemistry and PCR-based assays such as sequencing, mutation testing, microsatellite instability analysis, and determination of MLH1 methylation - are most helpful for guiding diagnosis and treatment of endometrial cancer. The central goal of this information is to provide a practical guide of key current and emerging issues in diagnostic endometrial cancer pathology that require the use of ancillary laboratory techniques, such as immunohistochemistry and molecular testing. The authors present the common diagnostic problems in endometrial carcinoma pathology, types of endometrial carcinoma, description of tissue testing and markers, pathological features, and targeted therapy. PMID:23687522

  4. Application of the MALDI Biotyper to clinical microbiology: progress and potential.

    PubMed

    Kostrzewa, Markus

    2018-03-01

    The introduction of the MALDI Biotyper in laboratories substantially changed microbiology practice, this has been called a revolution. The system accelerated diagnostic while costs were reduced and accuracy was increased. In just a few years MALDI-TOF MS became the first-line identification tool for microorganisms. Ten years after its introduction, more than 2000 MALDI Biotyper systems are installed in laboratories which are performing routine diagnostic, and the number is still increasing. Areas covered: This article summarises changes in clinical microbiology introduced by the MALDI Biotyper and its effects, as it has been published in peer reviewed articles found in PubMed. Further, the potential of novel developments to increase the value of the system is described. Expert commentary: The MALDI Biotyper has significantly improved clinical microbiology in the area of microorganism identification. Now new developments and applications, e.g. for typing and resistance testing, might further increase its value in clinical microbiology. The systems might get the central diagnostic analyser which is getting integrated into the widely automated microbiology laboratories of the future.

  5. Performance of Dengue Diagnostic Tests in a Single-Specimen Diagnostic Algorithm.

    PubMed

    Hunsperger, Elizabeth A; Muñoz-Jordán, Jorge; Beltran, Manuela; Colón, Candimar; Carrión, Jessica; Vazquez, Jesus; Acosta, Luz Nereida; Medina-Izquierdo, Juan F; Horiuchi, Kalanthe; Biggerstaff, Brad J; Margolis, Harold S

    2016-09-15

    Anti-dengue virus (DENV) immunoglobulin M (IgM) seroconversion has been the reference standard for dengue diagnosis. However, paired specimens are rarely obtained, and the interval for this testing negates its usefulness in guiding clinical case management. The presence of DENV viremia and appearance of IgM during the febrile phase of dengue provides the framework for dengue laboratory diagnosis by using a single serum specimen. Archived paired serum specimens (n = 1234) from patients with laboratory-confirmed dengue from 2005 through 2011 were used to determine the diagnostic performance of real-time reverse transcription polymerase chain reaction (RT-PCR), for detection of DENV serotypes 1-4, and enzyme-linked immunosorbent assays (ELISAs), for detection of DENV nonstructural protein 1 (NS1) antigen and anti-DENV IgM. During 1-3 days after illness onset, real-time RT-PCR and NS1 antigen testing detected 82%-69% and 90%-84% of cases, respectively, as viremia levels declined, while anti-DENV IgM ELISA detected 5%-41% of cases as antibody appeared. Over the 10-day period of the febrile phase of dengue, the cumulative effect of using these 3 types of tests in a diagnostic algorithm confirmed ≥90% of dengue cases. The use of molecular or NS1 antigen tests to detect DENV and one to detect anti-DENV IgM in a single serum specimen collected during the first 10 days of illness accurately identified ≥90% of dengue primary and secondary cases. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  6. UK NEQAS survey of allergen component testing across the United Kingdom and other European countries

    PubMed Central

    Saleem, R.; Keymer, C.; Patel, D.; Egner, W.

    2017-01-01

    Summary The clinical utility of molecular diagnostic approaches in allergy investigation is being recognized increasingly to play a significant role in the management of allergic patients. Determining the sensitization pattern, which is best achieved through the use of component resolved diagnostics (CRD), allows effective risk stratification, appropriate treatment and patient selection for immunotherapy. In order to assess the diagnostic service provisions for in‐vitro allergy testing across Europe, a survey was carried out via the total immunoglobulin (Ig)E and specific IgE external quality assurance schemes run by UK National External Quality Assessment Service (NEQAS) Immunology, Immunochemistry and Allergy. This survey assessed allergy testing, and in particular allergen components offered by the laboratories, and found a wide variability in service provision, particularly between the United Kingdom and other European Union (EU) countries. Furthermore, there was lack of standardization for acquisition of clinical information to aid allergen (and component) selection, gating strategy, testing algorithms and clinical interpretation. Interestingly, a significant proportion of laboratories (the majority from EU) stated that they ‘used’ the results for peanut components for risk stratification. However, the vast majority of participants were unaware of guidelines relating to the use of allergen component testing, and agreed that further education would assist in reaching a common platform. Hence, this survey has highlighted that although CRD has been adopted into routine diagnostics across Europe, it is potentially compromised by lack of standardized protocols and guidance sources. Consequently, there is a need for local or national standards and education through External Quality Assurance services on the performance and application of CRD into allergy investigation. PMID:28423454

  7. Company profile: labceutics.

    PubMed

    Reis, Mark; Fe Paz, Maria; Olson, Tiffany

    2012-11-01

    Laboratories are often the forgotten partners in the delivery of personalized therapies to physicians worldwide, yet the research and quality of their service in delivering seamless test results to physicians can either enhance the value proposition of a targeted therapy or destroy it. The need for integrated highest quality laboratory networks in fragmented markets such as Europe and Asia are needed to truly leverage the power of companion diagnostics.

  8. [Blood volume for biochemistry determinations--laboratory needs and everyday practice].

    PubMed

    Sztefko, Krystyna; Mamica, Katarzyna; Bugajska, Jolanta; Maziarz, Barbara; Tomasik, Przemysław

    2014-01-01

    Blood loss due to diagnostic phlebotomy jest a very serious problem, especially for newborn, infants and critically ill patients on intensive care units. Although single blood loss can be easily tolerated in adults, in small babies and in patients who are frequently monitored based on laboratory tests iatrogenic anaemia can occur. To evaluate the blood volume drawn for routine biochemistry tests in relation to patient age and the number of parameters requested. Blood volume drawn for routine biochemistry measurements from patients hospitalized in University Children's Hospital (N = 2980, children age from one day to 18 years) and in University Hospital (N = 859, adults, aged > 1.8 years) in Cracow has been analyzed. Blood volume was calculated based on regular tube diameter and blood heights in the tube. In case of microvettes the blood volume was 0.2 ml. Statistical analysis has been performed by using PRISM 5.0. The statistical significance was set at p < 0.05. The mean values of blood volume were 3.02 +/- 0.92 ml and 4.12 +/- 0.68 ml in children and adults, respectively. Analyzing blood volume drawn in children using both microvettes and regular tubes, significant correlation between blood volume and patient age (p < 0.001) as well the number of requested parameters (p < 0.001). The latest relationship was true only for up to five parameters. However, analyzing the blood volume drawn into only into regular tubes blood volume was not related to patients age and number of laboratory tests requested. The proportion of microvettes used for blood collection was highest for newborns and infants, and in all cases where only one to three laboratory tests were requested. 1. All educational programs for nurses and doctors should include the information about current laboratory automation and methods miniaturization; 2) The amount of blood volume needed by laboratory for the requested number of tests should always be taken into account when diagnostic phlebotomy is necessary.

  9. Design of a Tablet Computer App for Facilitation of a Molecular Blood Culture Test in Clinical Microbiology and Preliminary Usability Evaluation

    PubMed Central

    Pape-Haugaard, Louise; Meltzer, Michelle C; Fuchs, Martin; Schønheyder, Henrik C; Hejlesen, Ole

    2016-01-01

    Background User mobility is an important aspect of the development of clinical information systems for health care professionals. Mobile phones and tablet computers have obtained widespread use by health care professionals, offering an opportunity for supporting the access to patient information through specialized applications (apps) while supporting the mobility of the users. The use of apps for mobile phones and tablet computers may support workflow of complex tasks, for example, molecular-based diagnostic tests in clinical microbiology. Multiplex Blood Culture Test (MuxBCT) is a molecular-based diagnostic test used for rapid identification of pathogens in positive blood cultures. To facilitate the workflow of the MuxBCT, a specialized tablet computer app was developed as an accessory to the diagnostic test. The app aims to reduce the complexity of the test by step-by-step guidance of microscopy and to assist users in reaching an exact bacterial or fungal diagnosis based on blood specimen observations and controls. Additionally, the app allows for entry of test results, and communication thereof to the laboratory information system (LIS). Objective The objective of the study was to describe the design considerations of the MuxBCT app and the results of a preliminary usability evaluation. Methods The MuxBCT tablet app was developed and set up for use in a clinical microbiology laboratory. A near-live simulation study was conducted in the clinical microbiology laboratory to evaluate the usability of the MuxBCT app. The study was designed to achieve a high degree of realism as participants carried out a scenario representing the context of use for the MuxBCT app. As the MuxBCT was under development, the scenario involved the use of molecular blood culture tests similar to the MuxBCT for identification of microorganisms from positive blood culture samples. The study participants were observed, and their interactions with the app were recorded. After the study, the participants were debriefed to clarify observations. Results Four medical laboratory technicians, for example, representative of end users of the app, participated in the clinical simulation study. Using the MuxBCT app, the study participants successfully identified and reported all microorganisms from the positive blood cultures examined. Three of the four participants reported that they found the app useful, while one study participant reported that she would prefer to make notes on paper and later enter them into the LIS. Conclusions The preliminary usability evaluation results indicate that use of the MuxBCT tablet app can facilitate the workflow of the MuxBCT diagnostic test. PMID:26993432

  10. First external quality assurance program for bloodstream Real-Time PCR monitoring of treatment response in clinical trials of Chagas disease.

    PubMed

    Ramírez, Juan C; Parrado, Rudy; Sulleiro, Elena; de la Barra, Anabelle; Rodríguez, Marcelo; Villarroel, Sandro; Irazu, Lucía; Alonso-Vega, Cristina; Alves, Fabiana; Curto, María A; García, Lineth; Ortiz, Lourdes; Torrico, Faustino; Gascón, Joaquim; Flevaud, Laurence; Molina, Israel; Ribeiro, Isabela; Schijman, Alejandro G

    2017-01-01

    Real-Time PCR (qPCR) testing is recommended as both a diagnostic and outcome measurement of etiological treatment in clinical practice and clinical trials of Chagas disease (CD), but no external quality assurance (EQA) program provides performance assessment of the assays in use. We implemented an EQA system to evaluate the performance of molecular biology laboratories involved in qPCR based follow-up in clinical trials of CD. An EQA program was devised for three clinical trials of CD: the E1224 (NCT01489228), a pro-drug of ravuconazole; the Sampling Study (NCT01678599), that used benznidazole, both conducted in Bolivia; and the CHAGASAZOL (NCT01162967), that tested posaconazole, conducted in Spain. Four proficiency testing panels containing negative controls and seronegative blood samples spiked with 1, 10 and 100 parasite equivalents (par. eq.)/mL of four Trypanosoma cruzi stocks, were sent from the Core Lab in Argentina to the participating laboratories located in Bolivia and Spain. Panels were analyzed simultaneously, blinded to sample allocation, at 4-month intervals. In addition, 302 random blood samples from both trials carried out in Bolivia were sent to Core Lab for retesting analysis. The analysis of proficiency testing panels gave 100% of accordance (within laboratory agreement) and concordance (between laboratory agreement) for all T. cruzi stocks at 100 par. eq./mL; whereas their values ranged from 71 to 100% and from 62 to 100% at 1 and 10 par. eq./mL, respectively, depending on the T. cruzi stock. The results obtained after twelve months of preparation confirmed the stability of blood samples in guanidine-EDTA buffer. No significant differences were found between qPCR results from Bolivian laboratory and Core Lab for retested clinical samples. This EQA program for qPCR analysis of CD patient samples may significantly contribute to ensuring the quality of laboratory data generated in clinical trials and molecular diagnostics laboratories of CD.

  11. Comparative Evaluation of 11 Commercialized Rapid Diagnostic Tests for Detecting Trypanosoma cruzi Antibodies in Serum Banks in Areas of Endemicity and Nonendemicity

    PubMed Central

    Albajar-Viñas, Pedro; Wilkins, Patricia P.; Nieto, Javier; Leiby, David A.; Paris, Luc; Scollo, Karenina; Flórez, Carolina; Guzmán-Bracho, Carmen; Luquetti, Alejandro O.; Calvo, Nidia; Tadokoro, Kenji; Saez-Alquezar, Amadeo; Palma, Pedro Pablo; Martin, Miguel

    2014-01-01

    Chagas disease is one of the main public health issues in Latin America. Increasingly during the past few decades, Trypanosoma cruzi infection has been detected in North America, Europe, and the Western Pacific, mainly as a result of population movement. The limited availability of rapid serological diagnostic tests hinders rapid diagnosis and early treatment in areas of endemicity and nonendemicity. In collaboration with 11 national reference laboratories (NRLs) from different geographical areas, we evaluated the performances of commercialized serological rapid diagnostic tests (RDT) for T. cruzi infection. Eleven commercialized T. cruzi infection RDTs were evaluated on a total of 474 samples extensively tested with at least three different techniques for Chagas disease, maintained at controlled low temperatures, and stored in the serum banks of the 11 NRLs. We measured the sensitivity, specificity, and concordance of each RDT and provided an additional questionnaire to evaluate its ease of use. The selected RDTs in this study were performed under controlled laboratory conditions. Out of the 11 RDTs, we found 8 of them to be useful, with the cassette format favored over the strip. We did not observe significant differences in RDT performances in the different regions. Overall, the performance results were lower than those disclosed by the manufacturers. The results of this evaluation validate the possibility of using RDTs to diagnose Chagas disease, thereby decreasing the time to treatment at a primary health care facility for patients who are willing to be treated. Further studies should be conducted in the laboratory and in the field to confirm these data, expressly to evaluate reproducibility in resource-limited settings, or using whole blood in clinical settings in areas of endemicity and nonendemicity. PMID:24808239

  12. Evaluation of Targeted Next-Generation Sequencing for Detection of Bovine Pathogens in Clinical Samples.

    PubMed

    Anis, Eman; Hawkins, Ian K; Ilha, Marcia R S; Woldemeskel, Moges W; Saliki, Jeremiah T; Wilkes, Rebecca P

    2018-07-01

    The laboratory diagnosis of infectious diseases, especially those caused by mixed infections, is challenging. Routinely, it requires submission of multiple samples to separate laboratories. Advances in next-generation sequencing (NGS) have provided the opportunity for development of a comprehensive method to identify infectious agents. This study describes the use of target-specific primers for PCR-mediated amplification with the NGS technology in which pathogen genomic regions of interest are enriched and selectively sequenced from clinical samples. In the study, 198 primers were designed to target 43 common bovine and small-ruminant bacterial, fungal, viral, and parasitic pathogens, and a bioinformatics tool was specifically constructed for the detection of targeted pathogens. The primers were confirmed to detect the intended pathogens by testing reference strains and isolates. The method was then validated using 60 clinical samples (including tissues, feces, and milk) that were also tested with other routine diagnostic techniques. The detection limits of the targeted NGS method were evaluated using 10 representative pathogens that were also tested by quantitative PCR (qPCR), and the NGS method was able to detect the organisms from samples with qPCR threshold cycle ( C T ) values in the 30s. The method was successful for the detection of multiple pathogens in the clinical samples, including some additional pathogens missed by the routine techniques because the specific tests needed for the particular organisms were not performed. The results demonstrate the feasibility of the approach and indicate that it is possible to incorporate NGS as a diagnostic tool in a cost-effective manner into a veterinary diagnostic laboratory. Copyright © 2018 Anis et al.

  13. Late diagnosis of influenza in adult patients during a seasonal outbreak.

    PubMed

    Choi, Seong-Ho; Chung, Jin-Won; Kim, Tark; Park, Ki-Ho; Lee, Mi Suk; Kwak, Yee Gyung

    2018-03-01

    Due to advances in diagnostic techniques, clinicians are more frequently performing influenza diagnostic tests and referring to their test results ahead of the administration of neuraminidase inhibitors (NAIs). To investigate the clinical significance of the time from symptom onset to laboratory diagnosis, we reviewed the clinical characteristics of adult patients with influenza who had an early laboratory diagnosis (ED) or a late laboratory diagnosis (LD) at one of four tertiary care centers during a seasonal outbreak of influenza. Clinical data were collected from 1,405 adults during the 2013 to 2014 influenza season. A patient was regarded as receiving an ED or LD if he/she received an influenza diagnostic test at 0 to 1 or 4 to 7 days after symptom onset, respectively. Early NAI therapy and late NAI therapy were defined as the administration of NAI ≤ 2 or > 2 days after symptom onset, respectively. Nearly half of the patients (47.0%) received an ED (n = 661), whereas 13.5% (n = 190) received a LD. Patients with a LD had initial symptoms of cough, sputum production, and dyspnea and experienced pneumonia, antibiotic therapy, hospitalization, and admission to the intensive care unit more often than those with an ED. NAI therapy and early NAI therapy were less frequent in patients with a LD than those with an ED. Of the analyzed baseline characteristics, age ≥ 50 years, influenza B infection, and diagnosis using a polymerase chain reaction test were significantly associated with a LD. LD was associated with inappropriate antiviral therapy and complicated presenting features in adult patients with seasonal influenza. ED of influenza should be emphasized, especially for older adults.

  14. Clinical Chemistry of Patients With Ebola in Monrovia, Liberia

    PubMed Central

    de Wit, Emmie; Kramer, Shelby; Prescott, Joseph; Rosenke, Kyle; Falzarano, Darryl; Marzi, Andrea; Fischer, Robert J.; Safronetz, David; Hoenen, Thomas; Groseth, Allison; van Doremalen, Neeltje; Bushmaker, Trenton; McNally, Kristin L.; Feldmann, Friederike; Williamson, Brandi N.; Best, Sonja M.; Ebihara, Hideki; Damiani, Igor A. C.; Adamson, Brett; Zoon, Kathryn C.; Nyenswah, Tolbert G.; Bolay, Fatorma K.; Massaquoi, Moses; Sprecher, Armand; Feldmann, Heinz; Munster, Vincent J.

    2016-01-01

    The development of point-of-care clinical chemistry analyzers has enabled the implementation of these ancillary tests in field laboratories in resource-limited outbreak areas. The Eternal Love Winning Africa (ELWA) outbreak diagnostic laboratory, established in Monrovia, Liberia, to provide Ebola virus and Plasmodium spp. diagnostics during the Ebola epidemic, implemented clinical chemistry analyzers in December 2014. Clinical chemistry testing was performed for 68 patients in triage, including 12 patients infected with Ebola virus and 18 infected with Plasmodium spp. The main distinguishing feature in clinical chemistry of Ebola virus–infected patients was the elevation in alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, and γ-glutamyltransferase levels and the decrease in calcium. The implementation of clinical chemistry is probably most helpful when the medical supportive care implemented at the Ebola treatment unit allows for correction of biochemistry derangements and on-site clinical chemistry analyzers can be used to monitor electrolyte balance. PMID:27471319

  15. Blood glucose measurement by glucometer in comparison with standard method in diagnosis of neonatal hypoglycemia.

    PubMed

    Nayeri, Fatemeh; Shariat, Mamak; Mousavi Behbahani, Hamid Modarres; Dehghan, Padideh; Ebrahim, Bita

    2014-01-01

    Hypoglycemia is considered as a serious risk factor in neonates. In the majority of cases, it occurs with no clinical symptoms. Accordingly, early diagnosis is extremely imperative, which can also lead to less morbidity and mortality. The aim of this study was to assess the importance of screening blood glucose using glucometer (known as a quick and cost-effective diagnostic test) in comparison with laboratory method. A total of 219 neonates at risk of hypoglycemia were included in this study. Blood glucose was measured by glucometer and laboratory. In addition glucose level of capillary blood was measured by glucometer at the same time. Sensitivity and specificity of capillary blood glucose measurement by glucometer were 83.5%, 97.5% respectively (ppv=80%), (npv=98%). Capillary blood glucose measured by glucometer has an acceptable sensitivity and specificity in measurement of neonatal blood glucose. Therefore measurement by glucometer is recommended as a proper diagnostic test.

  16. Biosafety standards for working with Crimean-Congo hemorrhagic fever virus.

    PubMed

    Weidmann, Manfred; Avsic-Zupanc, Tatjana; Bino, Silvia; Bouloy, Michelle; Burt, Felicity; Chinikar, Sadegh; Christova, Iva; Dedushaj, Isuf; El-Sanousi, Ahmed; Elaldi, Nazif; Hewson, Roger; Hufert, Frank T; Humolli, Isme; Jansen van Vuren, Petrus; Koçak Tufan, Zeliha; Korukluoglu, Gülay; Lyssen, Pieter; Mirazimi, Ali; Neyts, Johan; Niedrig, Matthias; Ozkul, Aykut; Papa, Anna; Paweska, Janusz; Sall, Amadou A; Schmaljohn, Connie S; Swanepoel, Robert; Uyar, Yavuz; Weber, Friedemann; Zeller, Herve

    2016-11-01

    In countries from which Crimean-Congo haemorrhagic fever (CCHF) is absent, the causative virus, CCHF virus (CCHFV), is classified as a hazard group 4 agent and handled in containment level (CL)-4. In contrast, most endemic countries out of necessity have had to perform diagnostic tests under biosafety level (BSL)-2 or -3 conditions. In particular, Turkey and several of the Balkan countries have safely processed more than 100 000 samples over many years in BSL-2 laboratories. It is therefore advocated that biosafety requirements for CCHF diagnostic procedures should be revised, to allow the tests required to be performed under enhanced BSL-2 conditions with appropriate biosafety laboratory equipment and personal protective equipment used according to standardized protocols in the countries affected. Downgrading of CCHFV research work from CL-4, BSL-4 to CL-3, BSL-3 should also be considered.

  17. Emerging technologies in point-of-care molecular diagnostics for resource-limited settings.

    PubMed

    Peeling, Rosanna W; McNerney, Ruth

    2014-06-01

    Emerging molecular technologies to diagnose infectious diseases at the point at which care is delivered have the potential to save many lives in developing countries where access to laboratories is poor. Molecular tests are needed to improve the specificity of syndromic management, monitor progress towards disease elimination and screen for asymptomatic infections with the goal of interrupting disease transmission and preventing long-term sequelae. In simplifying laboratory-based molecular assays for use at point-of-care, there are inevitable compromises between cost, ease of use and test performance. Despite significant technological advances, many challenges remain for the development of molecular diagnostics for resource-limited settings. There needs to be more advocacy for these technologies to be applied to infectious diseases, increased efforts to lower the barriers to market entry through streamlined and harmonized regulatory approaches, faster policy development for adoption of new technologies and novel financing mechanisms to enable countries to scale up implementation.

  18. Global Foot-and-Mouth Disease Research Update and Gap Analysis: 4 - Diagnostics.

    PubMed

    Knight-Jones, T J D; Robinson, L; Charleston, B; Rodriguez, L L; Gay, C G; Sumption, K J; Vosloo, W

    2016-06-01

    This study assessed knowledge gaps in foot-and-mouth disease (FMD) research in the field of diagnostics. The study took the form of a literature review (2011-15) combined with research updates collected in 2014 from 33 institutes from around the world. Findings were used to identify priority areas for future FMD research. Molecular and genetic technologies, including sequencing, are developing at an increasing rate both in terms of capability and affordability. These advances potentiate progress in many other fields of research, from vaccine development to epidemiology. The development of RT-LAMP represents an important breakthrough allowing greater use and access to molecular diagnostics. It is now possible to determine virus serotype using PCR, although only for certain virus pools, continued progress is needed to cover the global spectrum of FMD viruses. Progress has also been made in the development of pen-side rapid diagnostics, some with the ability to determine serotype. However, further advances in pen-side serotype or strain determination would benefit both FMD-free countries and endemic countries with limited access to well-resourced laboratories. Novel sampling methods that show promise include air sampling and baited ropes, the latter may aid sampling in wildlife and swine. Studies of infrared thermography for the early detection of FMD have not been encouraging, although investigations are ongoing. Multiplex tests have been developed that are able to simultaneously screen for multiple pathogens with similar clinical signs. Crucial for assessing FMDV freedom, tests exist to detect animals that have been infected with FMDV regardless of vaccination status; however, limitations exist, particularly when testing previously vaccinated animals. Novel vaccines are being developed with complementary DIVA tests for this purpose. Research is also needed to improve the current imprecise approaches to FMD vaccine matching. The development of simple, affordable tests increases access to FMD diagnostics, greatly benefiting regions with limited laboratory capacity. © 2016 Blackwell Verlag GmbH.

  19. Disk Crack Detection for Seeded Fault Engine Test

    NASA Technical Reports Server (NTRS)

    Luo, Huageng; Rodriguez, Hector; Hallman, Darren; Corbly, Dennis; Lewicki, David G. (Technical Monitor)

    2004-01-01

    Work was performed to develop and demonstrate vibration diagnostic techniques for the on-line detection of engine rotor disk cracks and other anomalies through a real engine test. An existing single-degree-of-freedom non-resonance-based vibration algorithm was extended to a multi-degree-of-freedom model. In addition, a resonance-based algorithm was also proposed for the case of one or more resonances. The algorithms were integrated into a diagnostic system using state-of-the- art commercial analysis equipment. The system required only non-rotating vibration signals, such as accelerometers and proximity probes, and the rotor shaft 1/rev signal to conduct the health monitoring. Before the engine test, the integrated system was tested in the laboratory by using a small rotor with controlled mass unbalances. The laboratory tests verified the system integration and both the non-resonance and the resonance-based algorithm implementations. In the engine test, the system concluded that after two weeks of cycling, the seeded fan disk flaw did not propagate to a large enough size to be detected by changes in the synchronous vibration. The unbalance induced by mass shifting during the start up and coast down was still the dominant response in the synchronous vibration.

  20. [Clinical microbiology laboratory and imported parasitic diseases].

    PubMed

    Martín-Rabadán, Pablo; Martínez-Ruiz, Rocío; Cuadros, Juan; Cañavate, Carmen

    2010-12-01

    Imported parasitosis represents an increasingly frequent diagnostic challenge for microbiology laboratories. A surge in immigration and international travel has led to a rise in the number of imported cases of parasitosis, and this trend is expected to continue in the future. The present article addresses this challenge by reviewing recommended diagnostic approaches and tests. Currently, microscopy is always recommended when analysing blood samples for parasites. If malaria is suspected, rapid antigen testing (including at least HRP2 antigen) should also be performed. The work-up for suspected leishmaniasis should include serology, culture, and in selected cases detection of antigen in urine. In suspected Chagas disease, two different serological tests should be performed. PCR for blood protozoa is highly sensitive, although it cannot be used to rule out Chagas disease, since this condition may be present without parasitemia. Accurate diagnosis of intestinal amebiasis usually requires PCR or antigen detection tests. In helminthiasis, traditional microscopy may need to be complemented with other tests, such as agar plate culture for strongyloidiasis, Og4C3 antigen detection for bancroftian filariasis, and antibody detection test for filariasis and schistosomiasis. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  1. 32 CFR 199.7 - Claims submission, review, and payment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....g., M.D., Ph.D., R.N., etc.) and provider number, if the individual signing the claim is not the... rendering the care, along with the individual's professional status (e.g., M.D., Ph.D., R.N., etc.). (xi... the beneficiary's signature. (1) Claims for laboratory and diagnostic tests and test interpretations...

  2. 32 CFR 199.7 - Claims submission, review, and payment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....g., M.D., Ph.D., R.N., etc.) and provider number, if the individual signing the claim is not the... rendering the care, along with the individual's professional status (e.g., M.D., Ph.D., R.N., etc.). (xi... the beneficiary's signature. (1) Claims for laboratory and diagnostic tests and test interpretations...

  3. 32 CFR 199.7 - Claims submission, review, and payment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....g., M.D., Ph.D., R.N., etc.) and provider number, if the individual signing the claim is not the... rendering the care, along with the individual's professional status (e.g., M.D., Ph.D., R.N., etc.). (xi... the beneficiary's signature. (1) Claims for laboratory and diagnostic tests and test interpretations...

  4. Specific Pathogen Free Macaque Colonies: A Review of Principles and Recent Advances for Viral Testing and Colony Management

    PubMed Central

    Yee, JoAnn L.; Vandeford, Thomas H.; Didier, Elizabeth S.; Gray, Stanton; Lewis, Anne; Roberts, Jeffrey; Taylor, Kerry; Bohm, Rudolf P.

    2016-01-01

    Specific Pathogen Free (SPF) macaques provide valuable animal models for biomedical research. In 1989 the National Center for Research Resources (now Office of Research Infrastructure Programs ORIP) of the National Institutes of Health initiated experimental research contracts to establish and maintain SPF colonies. The derivation and maintenance of SPF macaque colonies is a complex undertaking requiring knowledge of the biology of the agents for exclusion and normal physiology and behavior of macaques, application of the latest diagnostic technology, facilities management, and animal husbandry. This review provides information on the biology of the four viral agents targeted for exclusion in ORIP SPF macaque colonies, describes current state-of-the-art viral diagnostic algorithms, presents data from proficiency testing of diagnostic assays between laboratories at institutions participating in the ORIP SPF program, and outlines management strategies for maintaining the integrity of SPF colonies using results of diagnostic testing as a guide to decision making. PMID:26932456

  5. Monitoring and investigating natural disease by veterinary pathologists in diagnostic laboratories.

    PubMed

    O'Toole, D

    2010-01-01

    Many emerging diseases in animals are initially recognized by diagnostic pathologists in animal health laboratories using routine laboratory submissions, in conjunction with clinical veterinarians and wildlife biologists. Familiar recent examples are chronic wasting disease, bovine spongiform encephalopathy, West Nile encephalomyelitis in North America, and postweaning multisystemic wasting syndrome in pigs. The recognition of new diseases in animals requires that the curiosity of diagnosticians be articulated with the capacity of animal health laboratories to create effective diagnostic teams, solicit additional cases from the field at minimal cost to clients, and develop relationships with basic researchers. Bovine neosporosis is used as an example to illustrate how a disease investigation triggered by routine clinical accessions can have international ramifications. Between the late 1980s and 1995, diagnosticians with California's animal health laboratory system identified neosporosis as a cause of reproductive wastage in cattle, characterized the lesions, isolated the agent, defined routes of transmission, met Koch's postulates, and developed diagnostic assays. Diagnostic pathologists catalyzed the process. The neosporosis investigation in California suggests useful attributes of veterinary diagnostic laboratories that pursue emerging diseases identified through routine laboratory accessions.

  6. The Development of a Post-Baccalaureate Certificate Program in Molecular Diagnostics

    PubMed Central

    Williams, Gail S.; Brown, Judith D.; Keagle, Martha B.

    2000-01-01

    A post-baccalaureate certificate program in diagnostic molecular sciences was created in 1995 by the Diagnostic Genetic Sciences Program in the School of Allied Health at the University of Connecticut. The required on-campus lecture and laboratory courses include basic laboratory techniques, health care issues, cell biology, immunology, human genetics, research, management, and molecular diagnostic techniques and laboratory in molecular diagnostics. These courses precede a 6-month, full-time practicum at an affiliated full-service molecular laboratory. The practicum includes amplification and blotting methods, a research project, and a choice of specialized electives including DNA sequencing, mutagenesis, in situ hybridization methods, or molecular diagnostic applications in microbiology. Graduates of the program are immediately eligible to sit for the National Credentialing Agency examination in molecular biology to obtain the credential Clinical Laboratory Specialist in Molecular Biology (CLSp(MB). This description of the University of Connecticut program may assist other laboratory science programs in creating similar curricula. PMID:11232107

  7. Development and validation of an anti-N3 indirect immunofluorescent antibody test to be used as a companion diagnostic test in the framework of a "DIVA" vaccination strategy for avian influenza infections in poultry.

    PubMed

    Cattoli, Giovanni; Milani, Adelaide; Bettini, Francesca; Serena Beato, Maria; Mancin, Marzia; Terregino, Calogero; Capua, Ilaria

    2006-04-01

    Avian influenza (AI) infections have become of growing importance both for animal and human health. Vaccination has become a recommended tool to support eradication efforts and limit the economic losses caused by this disease. The "DIVA" system, using a vaccine containing a heterologous neuraminidase to the field virus, has been shown to be an effective tool in increasing the resistance of birds to field challenge, preventing clinical signs and reducing viral shedding in the environment. The companion diagnostic test to the vaccine, however, has been only partially validated in the field against one subtype of neuraminidase (N1). The present paper presents the results of a full laboratory and field validation of the diagnostic test developed to detect antibodies to the N3 subtype of AI in vaccinated and unvaccinated chickens and turkeys. Antibody kinetic studies conducted in the laboratory have shown that antibodies to the N protein may be detected earlier than antibodies to the haemagglutinin. The data derived from this extensive validation trial indicate the excellent capability of this assay in detecting the presence of active AI infection at an early stage in both unvaccinated and vaccinated birds and the lack of interference with vaccine-induced antibodies.

  8. Care Model Design for E-Health: Integration of Point-of-Care Testing at Dutch General Practices

    PubMed Central

    Verhees, Bart; van Kuijk, Kees

    2017-01-01

    Point-of-care testing (POCT)—laboratory tests performed with new mobile devices and online technologies outside of the central laboratory—is rapidly outpacing the traditional laboratory test market, growing at a rate of 12 to 15% each year. POCT impacts the diagnostic process of care providers by yielding high efficiency benefits in terms of turnaround time and related quality improvements in the reduction of errors. However, the implementation of this disruptive eHealth technology requires the integration and transformation of diagnostic services across the boundaries of healthcare organizations. Research has revealed both advantages and barriers of POCT implementations, yet to date, there is no business model for the integration of POCT within general practice. The aim of this article is to contribute with a design for a care model that enables the integration of POCT in primary healthcare. In this research, we used a design modelling toolkit for data collection at five general practices. Through an iterative design process, we modelled the actors and value transactions, and designed an optimized care model for the dynamic integration of POCTs into the GP’s network of care delivery. The care model design will have a direct bearing on improving the integration of POCT through the connectivity and norm guidelines between the general practice, the POC technology, and the diagnostic centre. PMID:29267224

  9. Diagnostic performances of clinical laboratory tests using Triton X-100 to reduce the biohazard associated with routine testing of Ebola virus-infected patients.

    PubMed

    Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo

    2015-11-01

    Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.

  10. [Revolution of the health care delivery system and its impacts on laboratory testing in the United States].

    PubMed

    Takemura, Y; Ishibashi, M

    2000-02-01

    Failure to slow the exponential growth of total health care expenditures in the United States through the government policies resulted in a rapid and progressive penetration of managed care organizations(MCOs) in the early 1990s. Diagnostic testing is viewed as a "commodity" rather than a medical service under the managed care environment. Traditional hospital-based laboratories are placed in a downward spiral with the advent of managed care era. A massive reduction of in-house testing resulted from shorter lengths of patients' hospital stay and a marked decrease in admission under the dominance of managed care urges them to develop strategies for restoring tests deprived by the managed care-associated new businesses: consolidation and networking, participation in the outreach-testing market, and point-of-care/satellite laboratory testing in non-traditional, ambulatory settings are major strategies for survival of hospital laboratories. A number of physicians' office laboratories(POLs) have been closed owing to regulatory restrictions imposed by the Clinical Laboratory Improvement Amendments of 1988(CLIA '88), and to the expanded penetration of MCOs which limit reimbursement to a very few in-house procedures. It seems likely that POLs and hospital laboratories continue to reduce test volumes, while commercial reference laboratories(CRLs) gain more tests through contracting with MCOs. In the current stream of managed care dominance in the United States, clinical laboratories are changing their basic operation focus and mission in response to the aggressively changing landscape. Traditional laboratories which are unwilling to adapt themselves to the new environment will not survive in this country.

  11. Establishing diagnostic cut-off criteria for the COBAS AmpliPrep/COBAS TaqMan HIV-1 Qualitative test through validation against the Amplicor DNA test v1.5 for infant diagnosis using dried blood spots.

    PubMed

    Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U

    2012-02-01

    As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Diagnostic value of screening tests in subgroups of women with recurrent pregnancy loss.

    PubMed

    Guzel, Ali Irfan; Erkılınç, Selçuk; Özer, Irfan; Celik, Yusuf; Yılmaz, Nafiye; Doğanay, Melike

    2015-03-01

    To evaluate the diagnostic value of screening laboratory tests in women who had recurrent pregnancy loss (RPL). A total of 252 women with RPL managed in our tertiary referral research and education hospital were included in the study. Risk factors recorded involved age, gravidity, parity, number of prior live births, number of pregnancy losses, and thrombophlia tests. The cases were divided into three different groups and each group was analyzed separately. There was no statistically significant difference between the first and second groups in terms of clinical and laboratory parameters (p > 0.05). In the third group, there was a statistically significant difference among cases in terms of parity, gravidity, number of pregnancy losses, serum AT III levels, APCR, and age of the women. According to the logistic regression model, odds ratios (95% CI) were 6.116 (3.797-9.852), 5.665 (2.657-12.079), 4.763 (3.099-7.321), 4.729 (3.080-7.260), 2.820 (1.836-4.333), and 1.911 (1.232-2.965), respectively. We do not recommend the screening of all women with RPL, but in women with high parity and those who had prior live birth pregnancies, increased AT III, and APCR may be diagnostic markers for subsequent pregnancy loss.

  13. Autoantibodies and their Judicious Use in Pediatric Rheumatology Practice.

    PubMed

    Saikia, Biman; Rawat, Amit; Vignesh, Pandiarajan

    2016-01-01

    Autoantibody testing forms an important part of diagnostic workup of patients in Pediatric rheumatology practice. However it is important to understand that the mere presence of autoantibodies does not necessarily mean the presence of an underlying autoimmune disease. Autoantibodies may be present decades before the development of clinical manifestations of an autoimmune disease and may be viewed as harbingers of Autoimmune disease. On the other hand, low-affinity autoantibodies may be present in normal healthy individuals; these natural autoantibodies serve an important function in immune regulation and tolerance. Autoantibody testing in pediatric practice mainly includes testing for anti-nuclear antibodies, anti-dsDNA antibodies, anti-neutrophil cytoplasmic autoantibodies and antiphospholipid antibodies. Rheumatoid factor and anti-CCP do not have much significance in the diagnostic schema in pediatric rheumatology, except perhaps for classification of juvenile idiopathic arthritis (JIA) and prognostication in late-onset polyarticular JIA. The positive predictive value (PPV) of any laboratory test depends on the prevalence of the disease in the population being tested. Hence, test ordering practices greatly impact the performance characteristics and positive predictive value of any laboratory test. A restricted test ordering only in patients with clinical signs and symptoms suggestive of autoimmune disease would thus greatly increase the PPV of tests such as antinuclear antibody used for diagnosing autoimmunity.

  14. Diagnosis of coccidioidomycosis by culture: safety considerations, traditional methods, and susceptibility testing.

    PubMed

    Sutton, Deanna A

    2007-09-01

    The recovery of Coccidioides spp. by culture and confirmation utilizing the AccuProbe nucleic acid hybridization method by GenProbe remain the definitive diagnostic method. Biosafety considerations from specimen collection through culture confirmation in the mycology laboratory are critical, as acquisition of coccidioidomycosis by laboratory workers is well documented. The designation of Coccidioides spp. as select agents of potential bioterrorism has mandated strict regulation of their transport and inventory. The genus appears generally susceptible, in vitro, although no defined breakpoints exist. Susceptibility testing may assist in documenting treatment failures.

  15. Diagnosis and treatment of dementia: 2. Diagnosis

    PubMed Central

    Feldman, Howard H.; Jacova, Claudia; Robillard, Alain; Garcia, Angeles; Chow, Tiffany; Borrie, Michael; Schipper, Hyman M.; Blair, Mervin; Kertesz, Andrew; Chertkow, Howard

    2008-01-01

    Background Dementia can now be accurately diagnosed through clinical evaluation, cognitive screening, basic laboratory evaluation and structural imaging. A large number of ancillary techniques are also available to aid in diagnosis, but their role in the armamentarium of family physicians remains controversial. In this article, we provide physicians with practical guidance on the diagnosis of dementia based on recommendations from the Third Canadian Consensus Conference on the Diagnosis and Treatment of Dementia, held in March 2006. Methods We developed evidence-based guidelines using systematic literature searches, with specific criteria for study selection and quality assessment, and a clear and transparent decision-making process. We selected studies published from January 1996 to December 2005 that pertained to key diagnostic issues in dementia. We graded the strength of evidence using the criteria of the Canadian Task Force on Preventive Health Care. Results Of the 1591 articles we identified on all aspects of dementia diagnosis, 1095 met our inclusion criteria; 620 were deemed to be of good or fair quality. From a synthesis of the evidence in these studies, we made 32 recommendations related to the diagnosis of dementia. There are clinical criteria for diagnosing most forms of dementia. A standard diagnostic evaluation can be performd by family physicians over multiple visits. It involves a clinical history (from patient and caregiver), a physical examination and brief cognitive testing. A list of core laboratory tests is recommended. Structural imaging with computed tomography or magnetic resonance imaging is recommended in selected cases to rule out treatable causes of dementia or to rule in cerebrovascular disease. There is insufficient evidence to recommend routine functional imaging, measurement of biomarkers or neuropsychologic testing. Interpretation The diagnosis of dementia remains clinically integrative based on history, physical examination and brief cognitive testing. A number of core laboratory tests are also recommended. Structural neuroimaging is advised in selected cases. Other diagnostic approaches, including functional neuroimaging, neuropsychological testing and measurement of biomarkers, have shown promise but are not yet recommended for routine use by family physicians. PMID:18362376

  16. Mechanical DT and NDT: characterisation of building stones and research of correlation for in situ analysis of ancient masonries

    NASA Astrophysics Data System (ADS)

    Vasanelli, E.; Calia, A.; Aiello, M. A.; Sileo, M.; Leucci, G.

    2012-04-01

    Restoration works of the historical-architectural built heritage move from the typological and mechanical qualification of the buildings. Minimum destructive impact is required in preliminary diagnostic studies for the interventions, as it is possible. The use of the undestructive and non-invasive diagnostic techniques has always advantages in the activities on pre-existing buildings, in terms of sustainability; moreover, it is a need with respect to the conservation constraints when we act on the historical-architectural heritage. This work deals with destructive and non-destructive tests for the mechanical characterisation of some traditional soft stones, used as building materials in the Southern Italy; it is a part of a larger activity devoted to set up non-invasive diagnostic procedures for the mechanical analysis and qualification of ancient masonries. The laboratory experimental activity is based on the use of mechanical compressive tests, ultrasonic and Schmidt-Hammer tests, and the research of correlation between the results obtained by these crossed tests. It is aimed to verify the effectiveness and/or to point out critical aspects and limits of the above mentioned non-destructive tests - already applied in the field of the concrete and compact stones - with reference to the characterisation of the soft stones. The research of correlations between the results of destructive and non destructive tests has the final aim to reduce the use of destructive analyses on the masonries, by acquiring substitutive information derivable from performing NDT in laboratory, as well as in situ conditions. Finally, data gathered by the mechanical characterisation give reference values for the evaluation and control of the effectiveness of restoration interventions and their monitoring. This activity is carried out in an interdisciplinary way within the AITECH network (Applied Innovation Technologies for Diagnosis and Conservation of Built Heritage), a regional research laboratory infrastructure (Apulian region, Southern Italy) funded within the FSE and FESR programs and realised by the contribution of the Italian CNR and Salento University.

  17. How patients navigate the diagnostic ecosystem in a fragmented health system: a qualitative study from India

    PubMed Central

    Yellapa, Vijayashree; Devadasan, Narayanan; Krumeich, Anja; Pant Pai, Nitika; Vadnais, Caroline; Pai, Madhukar; Engel, Nora

    2017-01-01

    ABSTRACT Background: Depending on a country’s diagnostic infrastructure, patients and providers play different roles in ensuring that correct and timely diagnosis is made. However, little is known about the work done by patients in accessing diagnostic services and completing the ‘test and treat’ loop. Objective: To address this knowledge gap, we traced the diagnostic journeys of patients with tuberculosis, diabetes, hypertension and typhoid, and examined the work they had to do to arrive at a diagnosis. Methods: This paper draws on a qualitative study, which included 78 semi-structured interviews and 13 focus group discussions with patients, public and private healthcare providers, community health workers, test manufacturers, laboratory technicians, program managers and policymakers. Data were collected between January and June 2013 in rural and urban Karnataka, South India, as part of a larger project on barriers to point-of-care testing. We reconstructed patient diagnostic processes retrospectively and analyzed emerging themes and patterns. Results: The journey to access diagnostic services requires a high level of involvement and immense work from patients and/or their caretakers. This process entails overcoming cost and distance, negotiating social relations, continuously making sense of their illness and diagnosis, producing and transporting samples, dealing with the social consequences of diagnosis, and returning results to the treating provider. The quality and content of interactions with providers were crucial for completion of test and treat loops. If the tasks became overwhelming, patients opted out, delayed being tested, switched providers and/or reverted to self-testing or self-treatment practices. Conclusion: Our study demonstrated how difficult it can be for patients to complete diagnostic journeys and how the health system works as far as diagnostics are concerned. If new point-of-care tests are to be implemented successfully, policymakers, program officers and test developers need to find ways to ease patient navigation through diagnostic services. PMID:28762894

  18. Rapid molecular assays for detection of tuberculosis.

    PubMed

    Eddabra, Rkia; Ait Benhassou, Hassan

    2018-01-01

    Tuberculosis (TB) is an infectious disease that remains an important public health problem at the global level. It is one of the main causes of morbidity and mortality, due to the emergence of antibiotic resistant Mycobacterium strains and HIV co-infection. Over the past decade, important progress has been made for better control of the disease. While microscopy and culture continue to be indispensible for laboratory diagnosis of tuberculosis, the range of several molecular diagnostic tests, including the nucleic acid amplification test (NAAT) and whole-genome sequencing (WGS), have expanded tremendously. They are becoming more accessible not only for detection and identification of Mycobacterium tuberculosis complex in clinical specimens, but now extend to diagnosing multi-drug resistant strains. Molecular diagnostic tests provide timely results useful for high-quality patient care, low contamination risk, and ease of performance and speed. This review focuses on the current diagnostic tests in use, including emerging technologies used for detection of tuberculosis in clinical specimens. The sensitivity and specificity of these tests have also been taken into consideration.

  19. 78 FR 1824 - Notice of Request for Approval of an Information Collection; National Veterinary Services...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ... disease that affects the central nervous system of cattle. As part of the surveillance program, NVSL tests... accurate laboratory support is provided by their nationwide animal health diagnostic system. In 2006, APHIS...

  20. Decision Modeling in Sleep Apnea: The Critical Roles of Pretest Probability, Cost of Untreated Obstructive Sleep Apnea, and Time Horizon.

    PubMed

    Moro, Marilyn; Westover, M Brandon; Kelly, Jessica; Bianchi, Matt T

    2016-03-01

    Obstructive sleep apnea (OSA) is associated with increased morbidity and mortality, and treatment with positive airway pressure (PAP) is cost-effective. However, the optimal diagnostic strategy remains a subject of debate. Prior modeling studies have not consistently supported the widely held assumption that home sleep testing (HST) is cost-effective. We modeled four strategies: (1) treat no one; (2) treat everyone empirically; (3) treat those testing positive during in-laboratory polysomnography (PSG) via in-laboratory titration; and (4) treat those testing positive during HST with auto-PAP. The population was assumed to lack independent reasons for in-laboratory PSG (such as insomnia, periodic limb movements in sleep, complex apnea). We considered the third-party payer perspective, via both standard (quality-adjusted) and pure cost methods. The preferred strategy depended on three key factors: pretest probability of OSA, cost of untreated OSA, and time horizon. At low prevalence and low cost of untreated OSA, the treat no one strategy was favored, whereas empiric treatment was favored for high prevalence and high cost of untreated OSA. In-laboratory backup for failures in the at-home strategy increased the preference for the at-home strategy. Without laboratory backup in the at-home arm, the in-laboratory strategy was increasingly preferred at longer time horizons. Using a model framework that captures a broad range of clinical possibilities, the optimal diagnostic approach to uncomplicated OSA depends on pretest probability, cost of untreated OSA, and time horizon. Estimating each of these critical factors remains a challenge warranting further investigation. © 2016 American Academy of Sleep Medicine.

  1. Market assessment of tuberculosis diagnostics in Brazil in 2012.

    PubMed

    2014-01-01

    Improved diagnostics for the diagnosis of tuberculosis (TB) are urgently needed. However, test developers and investors require market size data to support new product development. This study assessed the served available market for TB diagnostics in Brazil in 2012 and the market segmentation in the public and private sectors. Data were collected on test volumes done in the public and private sectors for the diagnosis of latent and active TB, drug susceptibility testing and treatment follow-up. Tests included were tuberculin skin tests, interferon-gamma releases assays, smear microscopy, solid and liquid cultures, nucleic acid amplification tests and phenotypic drug susceptibility tests. The data were collected by means of an electronic survey via the Brazilian State laboratories and from sales information provided by manufacturers. Test costs for the public sector were calculated using a components approach, while costs for the private sector were based on prices paid by patients. The overall market value (expenditure) for the entire country was calculated using the public sector test costs. During 2012, an estimated total of 2.4 million TB diagnostic tests were done in Brazil, resulting in an estimated overall market value of USD 17.2 million. The public sector accounted for 91% of the test volumes and 88% of the market value. Smear microscopy was the most commonly test (n = 1.3 million; 55% of total) at an estimated value of USD 3.7 million. Culture overall (n = 302,761) represented 13% of test volumes and 40% (USD 6.9 million) of the market value. On average, USD 208 was spent on TB diagnostics for every notified TB patient in Brazil, in 2012. The TB diagnostics market value in Brazil in 2012 was over USD 17 million. These study results will help test developers to understand the current and potential market for replacement or add-on diagnostic technologies.

  2. Market Assessment of Tuberculosis Diagnostics in Brazil in 2012

    PubMed Central

    2014-01-01

    Background Improved diagnostics for the diagnosis of tuberculosis (TB) are urgently needed. However, test developers and investors require market size data to support new product development. This study assessed the served available market for TB diagnostics in Brazil in 2012 and the market segmentation in the public and private sectors. Methods Data were collected on test volumes done in the public and private sectors for the diagnosis of latent and active TB, drug susceptibility testing and treatment follow-up. Tests included were tuberculin skin tests, interferon-gamma releases assays, smear microscopy, solid and liquid cultures, nucleic acid amplification tests and phenotypic drug susceptibility tests. The data were collected by means of an electronic survey via the Brazilian State laboratories and from sales information provided by manufacturers. Test costs for the public sector were calculated using a components approach, while costs for the private sector were based on prices paid by patients. The overall market value (expenditure) for the entire country was calculated using the public sector test costs. Results During 2012, an estimated total of 2.4 million TB diagnostic tests were done in Brazil, resulting in an estimated overall market value of USD 17.2 million. The public sector accounted for 91% of the test volumes and 88% of the market value. Smear microscopy was the most commonly test (n = 1.3 million; 55% of total) at an estimated value of USD 3.7 million. Culture overall (n = 302,761) represented 13% of test volumes and 40% (USD 6.9 million) of the market value. On average, USD 208 was spent on TB diagnostics for every notified TB patient in Brazil, in 2012. Conclusion The TB diagnostics market value in Brazil in 2012 was over USD 17 million. These study results will help test developers to understand the current and potential market for replacement or add-on diagnostic technologies. PMID:25099237

  3. Informatics applied to cytology

    PubMed Central

    Hornish, Maryanne; Goulart, Robert A.

    2008-01-01

    Automation and emerging information technologies are being adopted by cytology laboratories to augment Pap test screening and improve diagnostic accuracy. As a result, informatics, the application of computers and information systems to information management, has become essential for the successful operation of the cytopathology laboratory. This review describes how laboratory information management systems can be used to achieve an automated and seamless workflow process. The utilization of software, electronic databases and spreadsheets to perform necessary quality control measures are discussed, as well as a Lean production system and Six Sigma approach, to reduce errors in the cytopathology laboratory. PMID:19495402

  4. NCCN Oncology Research Program's Investigator Steering Committee and NCCN Best Practices Committee Molecular Profiling Surveys.

    PubMed

    Kurzrock, Razelle; Colevas, A Dimitrios; Olszanski, Anthony; Akerley, Wallace; Arteaga, Carlos L; Carson, William E; Clark, Jeffrey W; DiPersio, John F; Ettinger, David S; Morgan, Robert J; Schwartzberg, Lee S; Venook, Alan P; Gocke, Christopher D; Tait, Jonathan; Stewart, F Marc

    2015-11-01

    With advances such as next-generation sequencing (NGS) increasing understanding of the basis of cancer and its response to treatment, NCCN believes it is important to understand how molecular profiling/diagnostic testing is being performed and used at NCCN Member Institutions and their community affiliates. The NCCN Oncology Research Program's Investigator Steering Committee and the NCCN Best Practices Committee gathered baseline information on the use of cancer-related molecular testing at NCCN Member Institutions and community members of the NCCN Affiliate Research Consortium through 2 separate surveys distributed in December 2013 and September 2014, respectively. A total of 24 NCCN Member Institutions and 8 affiliate sites provided quantitative and qualitative data. In the context of these surveys, "molecular profiling/diagnostics" was defined as a panel of at least 10 genes examined as a diagnostic DNA test in a Clinical Laboratory Improvement Amendments (CLIA)-certified laboratory. Results indicated that molecular profiling/diagnostics are used at 100% of survey respondents' institutions to make patient care decisions. However, challenges relating to reimbursement, lack of data regarding actionable targets and targeted therapies, and access to drugs on or off clinical trials were cited as barriers to integration of molecular profiling into patient care. Frameworks for using molecular diagnostic results based on levels of evidence, alongside continued research into the predictive value of biomarkers and targeted therapies, are recommended to advance understanding of the role of genomic biomarkers. Greater evidence and consensus regarding the clinical and cost-effectiveness of molecular profiling may lead to broader insurance coverage and increased integration into patient care. Copyright © 2015 by the National Comprehensive Cancer Network.

  5. Practical issues in implementing whole-genome-sequencing in routine diagnostic microbiology.

    PubMed

    Rossen, J W A; Friedrich, A W; Moran-Gilad, J

    2018-04-01

    Next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology adopted in microbiology, the integration of NGS into clinical and routine workflows must be carefully managed. To review the practical aspects of implementing bacterial whole genome sequencing (WGS) in routine diagnostic laboratories. Review of the literature and expert opinion. In this review, we discuss when and how to integrate whole genome sequencing (WGS) in the routine workflow of the clinical laboratory. In addition, as the microbiology laboratories have to adhere to various national and international regulations and criteria for their accreditation, we deliberate on quality control issues for using WGS in microbiology, including the importance of proficiency testing. Furthermore, the current and future place of this technology in the diagnostic hierarchy of microbiology is described as well as the necessity of maintaining backwards compatibility with already established methods. Finally, we speculate on the question of whether WGS can entirely replace routine microbiology in the future and the tension between the fact that most sequencers are designed to process multiple samples in parallel whereas for optimal diagnosis a one-by-one processing of the samples is preferred. Special reference is made to the cost and turnaround time of WGS in diagnostic laboratories. Further development is required to improve the workflow for WGS, in particular to shorten the turnaround time, reduce costs, and streamline downstream data analyses. Only when these processes reach maturity will reliance on WGS for routine patient management and infection control management become feasible, enabling the transformation of clinical microbiology into a genome-based and personalized diagnostic field. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  6. Leapfrog diagnostics: Demonstration of a broad spectrum pathogen identification platform in a resource-limited setting

    PubMed Central

    2012-01-01

    Background Resource-limited tropical countries are home to numerous infectious pathogens of both human and zoonotic origin. A capability for early detection to allow rapid outbreak containment and prevent spread to non-endemic regions is severely impaired by inadequate diagnostic laboratory capacity, the absence of a “cold chain” and the lack of highly trained personnel. Building up detection capacity in these countries by direct replication of the systems existing in developed countries is not a feasible approach and instead requires “leapfrogging” to the deployment of the newest diagnostic systems that do not have the infrastructure requirements of systems used in developed countries. Methods A laboratory for molecular diagnostics of infectious agents was established in Bo, Sierra Leone with a hybrid solar/diesel/battery system to ensure stable power supply and a satellite modem to enable efficient communication. An array of room temperature stabilization and refrigeration technologies for reliable transport and storage of reagents and biological samples were also tested to ensure sustainable laboratory supplies for diagnostic assays. Results The laboratory demonstrated its operational proficiency by conducting an investigation of a suspected avian influenza outbreak at a commercial poultry farm at Bo using broad range resequencing microarrays and real time RT-PCR. The results of the investigation excluded influenza viruses as a possible cause of the outbreak and indicated a link between the outbreak and the presence of Klebsiella pneumoniae. Conclusions This study demonstrated that by application of a carefully selected set of technologies and sufficient personnel training, it is feasible to deploy and effectively use a broad-range infectious pathogen detection technology in a severely resource-limited setting. PMID:22759725

  7. A Recombinant Positive Control for Serology Diagnostic Tests Supporting Elimination of Onchocerca volvulus.

    PubMed

    Golden, Allison; Stevens, Eric J; Yokobe, Lindsay; Faulx, Dunia; Kalnoky, Michael; Peck, Roger; Valdez, Melissa; Steel, Cathy; Karabou, Potochoziou; Banla, Méba; Soboslay, Peter T; Adade, Kangi; Tekle, Afework H; Cama, Vitaliano A; Fischer, Peter U; Nutman, Thomas B; Unnasch, Thomas R; de los Santos, Tala; Domingo, Gonzalo J

    2016-01-01

    Serological assays for human IgG4 to the Onchocerca volvulus antigen Ov16 have been used to confirm elimination of onchocerciasis in much of the Americas and parts of Africa. A standardized source of positive control antibody (human anti-Ov16 IgG4) will ensure the quality of surveillance data using these tests. A recombinant human IgG4 antibody to Ov16 was identified by screening against a synthetic human Fab phage display library and converted into human IgG4. This antibody was developed into different positive control formulations for enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT) platforms. Variation in ELISA results and utility as a positive control of the antibody were assessed from multiple laboratories. Temperature and humidity conditions were collected across seven surveillance activities from 2011-2014 to inform stability requirements for RDTs and positive controls. The feasibility of the dried positive control for RDT was evaluated during onchocerciasis surveillance activity in Togo, in 2014. When the anti-Ov16 IgG4 antibody was used as a standard dilution in horseradish peroxidase (HRP) and alkaline phosphatase (AP) ELISAs, the detection limits were approximately 1ng/mL by HRP ELISA and 10ng/mL by AP ELISA. Positive control dilutions and spiked dried blood spots (DBS) produced similar ELISA results. Used as a simple plate normalization control, the positive control antibody may improve ELISA data comparison in the context of inter-laboratory variation. The aggregate temperature and humidity monitor data informed temperature parameters under which the dried positive control was tested and are applicable inputs for testing of diagnostics tools intended for sub-Saharan Africa. As a packaged positive control for Ov16 RDTs, stability of the antibody was demonstrated for over six months at relevant temperatures in the laboratory and for over 15 weeks under field conditions. The recombinant human anti-Ov16 IgG4 antibody-based positive control will benefit inter-laboratory validation of ELISA assays and serve as quality control (QC) reagents for Ov16 RDTs at different points of the supply chain from manufacturer to field use.

  8. Fever case management at private health facilities and private pharmacies on the Kenyan coast: analysis of data from two rounds of client exit interviews and mystery client visits.

    PubMed

    Poyer, Stephen; Musuva, Anne; Njoki, Nancy; Okara, Robi; Cutherell, Andrea; Sievers, Dana; Lussiana, Cristina; Memusi, Dorothy; Kiptui, Rebecca; Ejersa, Waqo; Dolan, Stephanie; Charman, Nicole

    2018-03-13

    Private sector availability and use of malaria rapid diagnostic tests (RDTs) lags behind the public sector in Kenya. Increasing channels through which quality malaria diagnostic services are available can improve access to testing and help meet the target of universal diagnostic testing. Registered pharmacies are currently not permitted to perform blood tests, and evidence of whether malaria RDTs can be used by non-laboratory private providers in line with the national malaria control guidelines is required to inform ongoing policy discussions in Kenya. Two rounds of descriptive cross-sectional exit interviews and mystery client surveys were conducted at private health facilities and registered pharmacies in 2014 and 2015, 6 and 18 months into a multi-country project to prime the private sector market for the introduction of RDTs. Data were collected on reported RDT use, medicines received and prescribed, and case management of malaria test-negative mystery clients. Analysis compared outcomes at facilities and pharmacies independently for the two survey rounds. Across two rounds, 534 and 633 clients (including patients) from 130 and 120 outlets were interviewed, and 214 and 250 mystery client visits were completed. Reported testing by any malaria diagnostic test was higher in private health facilities than registered pharmacies in both rounds (2014: 85.6% vs. 60.8%, p < 0.001; 2015: 85.3% vs. 56.3%, p < 0.001). In registered pharmacies, testing by RDT was 52.1% in 2014 and 56.3% in 2015. At least 75% of test-positive patients received artemisinin-based combination therapy (ACT) in both rounds, with no significant difference between outlet types in either round. Provision of any anti-malarial for test-negative patients ranged from 0 to 13.9% across outlet types and rounds. In 2015, mystery clients received the correct (negative) diagnosis and did not receive an anti-malarial in 75.5% of visits to private health facilities and in 78.4% of visits to registered pharmacies. Non-laboratory staff working in registered pharmacies in Kenya can follow national guidelines for diagnosis with RDTs when provided with the same level of training and supervision as private health facility staff. Performance and compliance to treatment recommendations are comparable to diagnostic testing outcomes recorded in private health facilities.

  9. Avian toxicologic diagnosis

    USGS Publications Warehouse

    Sigurdson, C.J.; Franson, J.C.; Fudge, A.M.

    2000-01-01

    This chapter describes the sources and pathophysiology of some potential poisons that affect birds and summarizes useful laboratory tests. The diagnosis of poisoning in birds, as in mammals, requires a complete and accurate history, careful observation of clinical signs, and a thorough necropsy evaluation. Appropriate sample handling and analysis, based on consultation with the diagnostic toxicologist, are critical (Table 19--1). Veterinary toxicology laboratories are becoming increasingly specialized, with only certain laboratories capable of analyzing for drug residues or anticoagulants, for example. Although a local laboratory may not be able to fulfill a specific test request, they may recommend an alternative laboratory or may be willing to forward the sample. As a general rule in suspect poisoning cases, large tissue samples of liver, kidney, brain, and subcutaneous fat and of crop, proventriculus, and ventriculus contents should be collected at necropsy and frozen. Appropriate samples should be submitted frozen, with the remainder held in the freezer for possible later testing. A second set of tissues should be placed in 10% formalin for histopathologic examination.

  10. Rubella Surveillance and Diagnostic Testing among a Low-Prevalence Population, New York City, 2012-2013.

    PubMed

    Isaac, Beth M; Zucker, Jane R; Giancotti, Francesca R; Abernathy, Emily; Icenogle, Joseph; Rakeman, Jennifer L; Rosen, Jennifer B

    2017-09-01

    The New York City Department of Health and Mental Hygiene (DOHMH) receives clinical and laboratory reports for rubella. Because rubella immunoglobulin M (IgM) assays may produce false-positive results and rubella infections may be asymptomatic, interpretation of positive IgM results can be challenging. Rubella reports received by DOHMH in 2012 to 2013 were reviewed. The rubella IgM testing purpose was determined through case investigation. Results of IgM testing by indirect enzyme-linked immunosorbent assay (ELISA) and capture enzyme immunoassay (EIA) were compared to determine positive predictive value (PPV) and specificity. DOHMH received 199 rubella reports; 2 were true cases. Of all reports, 77.9% were tested for rubella IgM erroneously, 19.6% were tested for diagnostic purposes, 2.0% had unknown test purpose, and 0.5% were not tested. PPV of indirect ELISA was 6% overall, 14% for diagnostic tests, and 0% for tests ordered erroneously. PPV of capture EIA was 29% overall, 50% for diagnostic tests, and 0% for tests ordered erroneously. Overall, specificity was 52% for indirect ELISA and 85% for capture EIA. Limiting rubella IgM testing to patients for whom rubella diagnosis is suspected and using a more specific IgM assay have the potential to reduce false-positive rubella IgM results. Copyright © 2017 American Society for Microbiology.

  11. The role of laboratory in ensuring appropriate test requests.

    PubMed

    Ferraro, Simona; Panteghini, Mauro

    2017-07-01

    This review highlights the role of laboratory professionals and the strategies to be promoted in strict cooperation with clinicians for auditing, monitoring and improving the appropriateness of test request. The introduction of local pathways and care maps in agreement with international and national guidelines as well as the implementation of reflex testing and algorithms have a central role in guiding test request and in correcting the overuse/misuse of tests. Furthermore, removing obsolete tests from laboratory menu and vetting of restricted tests is recommended to increase cost-effectiveness. This saves costs and permits to introduce new biomarkers with increased diagnostic accuracy with a better impact on patient outcome. An additional issue is concerning the periodicity of (re)testing, accounting that only a minority of tests may be ordered as often as necessary. In the majority of cases, a minimum retesting interval should be introduced. The availability of effective computerised order entry systems is relevant in ensuring appropriate test requests and in providing an aid by automated rules that may stop inappropriate requests before they reach the laboratory. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Systematic Assessment of the Hemolysis Index: Pros and Cons.

    PubMed

    Lippi, Giuseppe

    2015-01-01

    Preanalytical quality is as important as the analytical and postanalytical quality in laboratory diagnostics. After decades of visual inspection to establish whether or not a diagnostic sample may be suitable for testing, automated assessment of hemolysis index (HI) has now become available in a large number of laboratory analyzers. Although most national and international guidelines support systematic assessment of sample quality via HI, there is widespread perception that this indication has not been thoughtfully acknowledged. Potential explanations include concern of increased specimen rejection rate, poor harmonization of analytical techniques, lack of standardized units of measure, differences in instrument-specific cutoff, negative impact on throughput, organization and laboratory economics, and lack of a reliable quality control system. Many of these concerns have been addressed. Evidence now supports automated HI in improving quality and patient safety. These will be discussed. © 2015 Elsevier Inc. All rights reserved.

  13. The value of the Thomas-plot in the diagnostic work up of anemic patients referred by general practitioners.

    PubMed

    Leers, M P G; Keuren, J F W; Oosterhuis, W P

    2010-12-01

    In patients with inflammatory conditions, diagnosing classic iron deficiency or anemia of chronic disease is challenging. In this study, we assessed the diagnostic value of the so-called Thomas'-plot [soluble transferrin receptor (sTfR)/log ferritin (sTfr/log Ferr) and the reticulocyte hemoglobin equivalent (Ret-HE)] in the anemia work up of patients referred by general practitioners. During July 2008-March 2009, 337 consecutive patients were included because of lowered Hb values. The laboratory results of the first 133 consecutive patients were used to determine the cut-off values for the diagnostic plot. The laboratory results of these patients were assessed and interpreted independently by two investigators, blinded from sTfR/log Ferr and Ret-HE values. The following 204 patients were used to test the plot in practice. In 32% of the first 133 patients, no indication of the cause of anemia could be found. However, when using the diagnostic plot in the following 204 patients, this fraction decreased to 14%. The 'Thomas'-plot is of diagnostic value for distinguishing functional iron deficiency from classic iron deficiency in a patient population referred by general practitioners. © 2010 Blackwell Publishing Ltd.

  14. Agreement between allergen-specific IgE assays and ensuing immunotherapy recommendations from four commercial laboratories in the USA

    PubMed Central

    Plant, Jon D; Neradelik, Moni B; Polissar, Nayak L; Fadok, Valerie A; Scott, Brian A

    2014-01-01

    Background Canine allergen-specific IgE assays in the USA are not subjected to an independent laboratory reliability monitoring programme. Hypothesis/Objectives The aim of this study was to evaluate the agreement of diagnostic results and treatment recommendations of four serum IgE assays commercially available in the USA. Methods Replicate serum samples from 10 atopic dogs were submitted to each of four laboratories for allergen-specific IgE assays (ACTT®, VARL Liquid Gold, ALLERCEPT® and Greer® Aller-g-complete®). The interlaboratory agreement of standard, regional panels and ensuing treatment recommendations were analysed with the kappa statistic (κ) to account for agreement that might occur merely by chance. Six comparisons of pairs of laboratories and overall agreement among laboratories were analysed for ungrouped allergens (as tested) and also with allergens grouped according to reported cross-reactivity and taxonomy. Results The overall chance-corrected agreement of the positive/negative test results for ungrouped and grouped allergens was slight (κ = 0.14 and 0.13, respectively). Subset analysis of the laboratory pair with the highest level of diagnostic agreement (κ = 0.36) found slight agreement (κ = 0.13) for ungrouped plants and fungi, but substantial agreement (κ = 0.71) for ungrouped mites. The overall agreement of the treatment recommendations was slight (κ = 0.11). Altogether, 85.1% of ungrouped allergen treatment recommendations were unique to one laboratory or another. Conclusions and clinical importance Our study indicated that the choice of IgE assay may have a major influence on the positive/negative results and ensuing treatment recommendations. PMID:24461034

  15. Diagnostic challenges in celiac disease.

    PubMed

    Kowalski, Karol; Mulak, Agata; Jasińska, Maria; Paradowski, Leszek

    2017-07-01

    Diagnosis of celiac disease in adults is currently based on serologic tests in combination with histopathological assessment of small intestinal biopsy specimens. High titers of celiac-specific antibodies in immunocompetent patients with villous atrophy in a good quality biopsy sample allow us to state a confident diagnosis. The relief of symptoms and histological improvement after embarking on a gluten free diet further support the initial diagnosis. However, in some cases, these conditions are not fulfilled, which requires a critical evaluation of laboratory and histopathology results and a consideration of other potential causes for the observed pathologies. To avoid diagnostic uncertainty, both biopsy and laboratory testing should be performed on a diet containing gluten. Immune deficiency, cross reaction of antibodies and possibilities of seronegative or latent celiac disease should be considered while evaluating serology results. Uneven distribution and variable intensity of histopathological changes in the small intestine along with multiple disorders presenting a similar specimen image may lead to invalid biopsy results. Additional laboratory testing and careful examination of a patient's history may deliver important data for a differential diagnosis and a more specific biopsy evaluation. Persistence or recurrence of symptoms, despite the ongoing treatment, requires a revision of the initial diagnosis, an evaluation of the gluten free diet and a search for concurrent disorders or complications.

  16. Developments in laboratory diagnostics for isocyanate asthma

    PubMed Central

    Wisnewski, Adam V.

    2011-01-01

    Purpose of review Isocyanates, reactive chemicals used to generate polyurethane, are a leading cause of occupational asthma worldwide. Workplace exposure is the best-recognized risk factor for disease development, but is challenging to monitor. Clinical diagnosis and differentiation of isocyanates as the cause of asthma can be difficult. The gold-standard test, specific inhalation challenge, is technically and economically demanding, and is thus only available in a few specialized centers in the world. With the increasing use of isocyanates, efficient laboratory tests for isocyanate asthma and exposure are urgently needed. Recent findings The review focuses on literature published in 2005 and 2006. Over 150 articles, identified by searching PubMed using keywords ‘diphenylmethane’, ‘toluene’ or ‘hexamethylene diisocyanate’, were screened for relevance to isocyanate asthma diagnostics. New advances in understanding isocyanate asthma pathogenesis are described, which help improve conventional radioallergosorbent and enzyme-linked immunosorbent assay approaches for measuring isocyanate-specific IgE and IgG. Newer immunoassays, based on cellular responses and discovery science readouts are also in development. Summary Contemporary laboratory tests that measure isocyanate-specific human IgE and IgG are of utility in diagnosing a subset of workers with isocyanate asthma, and may serve as a biomarker of exposure in a larger proportion of occupationally exposed workers. PMID:17351466

  17. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Nitrate/nitrite Test 66.00 67.00 68.00 70.00 72.00 Organic compound confirmation Test 88.00 90.00 92.00 94.00 96.00 Organic compound screen Test 151.00 155.00 158.00 161.00 165.00 Parasitology Test 29.00 29....00 103.00 105.00 107.00 Selenium Test 44.00 45.00 46.00 47.00 48.00 Silicate/carbonate disinfectant...

  18. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Nitrate/nitrite Test 66.00 67.00 68.00 70.00 72.00 Organic compound confirmation Test 88.00 90.00 92.00 94.00 96.00 Organic compound screen Test 151.00 155.00 158.00 161.00 165.00 Parasitology Test 29.00 29....00 103.00 105.00 107.00 Selenium Test 44.00 45.00 46.00 47.00 48.00 Silicate/carbonate disinfectant...

  19. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Nitrate/nitrite Test 66.00 67.00 68.00 70.00 72.00 Organic compound confirmation Test 88.00 90.00 92.00 94.00 96.00 Organic compound screen Test 151.00 155.00 158.00 161.00 165.00 Parasitology Test 29.00 29....00 103.00 105.00 107.00 Selenium Test 44.00 45.00 46.00 47.00 48.00 Silicate/carbonate disinfectant...

  20. What do providers, payers and patients need from comparative effectiveness research on diagnostics? The case of HER2/Neu testing in breast cancer.

    PubMed

    Trosman, Julia R; Weldon, Christine B; Schink, Julian C; Gradishar, William J; Benson, Al B

    2013-07-01

    Comparing effectiveness of diagnostic tests is one of the highest priorities for comparative effectiveness research (CER) set by the Institute of Medicine. Our study aims to identify what information providers, payers and patients need from CER on diagnostics, and what challenges they encounter implementing comparative information on diagnostic alternatives in practice and policy. Using qualitative research methods and the example of two alternative protocols for HER2 testing in breast cancer, we conducted interviews with 45 stakeholders: providers (n = 25) from four academic and eight nonacademic institutions, executives (n = 13) from five major US private payers and representatives (n = 7) from two breast cancer patient advocacies. The need for additional scientific evidence to determine the preferred HER2 protocol was more common for advocates than payers (100 vs 54%; p = 0.0515) and significantly more common for advocates than providers (100 vs 40%; p = 0.0077). The availability of information allowing assessment of the implementation impact from alternative diagnostic protocols on provider institutions may mitigate the need for additional scientific evidence for some providers and payers (24 and 46%, respectively). The cost-effectiveness of alternative protocols from the societal perspective is important to payers and advocates (69 and 71%, respectively) but not to providers (0%; p = 0.0001 and p = 0.0001). The lack of reporting laboratory practices is a more common implementation challenge for payers and advocates (77 and 86%, respectively) than for providers (32%). The absence of any mechanism for patient involvement was recognized as a challenge by payers and advocates (69 and 100%, respectively) but not by providers (0%; p = 0.0001 and p = 0.0001). Comparative implementation research is needed to inform the stakeholders considering diagnostic alternatives. Transparency of laboratory practices is an important factor in enabling implementation of CER on diagnostics in practice and policy. The incongruent views of providers versus patient advocates and payers on involving patients in diagnostic decisions is a concerning challenge to utilizing the results of CER.

Top