Sample records for diagnostic testing methods

  1. Myasthenia Gravis: Tests and Diagnostic Methods

    MedlinePlus

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  2. Systematic Review and Meta-Analysis of Studies Evaluating Diagnostic Test Accuracy: A Practical Review for Clinical Researchers-Part II. Statistical Methods of Meta-Analysis

    PubMed Central

    Lee, Juneyoung; Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies. PMID:26576107

  3. Diagnostic Profiles: A Standard Setting Method for Use with a Cognitive Diagnostic Model

    ERIC Educational Resources Information Center

    Skaggs, Gary; Hein, Serge F.; Wilkins, Jesse L. M.

    2016-01-01

    This article introduces the Diagnostic Profiles (DP) standard setting method for setting a performance standard on a test developed from a cognitive diagnostic model (CDM), the outcome of which is a profile of mastered and not-mastered skills or attributes rather than a single test score. In the DP method, the key judgment task for panelists is a…

  4. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    PubMed

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  5. Diagnostic Accuracy Assessment of Sensititre and Agar Disk Diffusion for Determining Antimicrobial Resistance Profiles of Bovine Clinical Mastitis Pathogens▿

    PubMed Central

    Saini, V.; Riekerink, R. G. M. Olde; McClure, J. T.; Barkema, H. W.

    2011-01-01

    Determining the accuracy and precision of a measuring instrument is pertinent in antimicrobial susceptibility testing. This study was conducted to predict the diagnostic accuracy of the Sensititre MIC mastitis panel (Sensititre) and agar disk diffusion (ADD) method with reference to the manual broth microdilution test method for antimicrobial resistance profiling of Escherichia coli (n = 156), Staphylococcus aureus (n = 154), streptococcal (n = 116), and enterococcal (n = 31) bovine clinical mastitis isolates. The activities of ampicillin, ceftiofur, cephalothin, erythromycin, oxacillin, penicillin, the penicillin-novobiocin combination, pirlimycin, and tetracycline were tested against the isolates. Diagnostic accuracy was determined by estimating the area under the receiver operating characteristic curve; intertest essential and categorical agreements were determined as well. Sensititre and the ADD method demonstrated moderate to highly accurate (71 to 99%) and moderate to perfect (71 to 100%) predictive accuracies for 74 and 76% of the isolate-antimicrobial MIC combinations, respectively. However, the diagnostic accuracy was low for S. aureus-ceftiofur/oxacillin combinations and other streptococcus-ampicillin combinations by either testing method. Essential agreement between Sensititre automatic MIC readings and MIC readings obtained by the broth microdilution test method was 87%. Essential agreement between Sensititre automatic and manual MIC reading methods was 97%. Furthermore, the ADD test method and Sensititre MIC method exhibited 92 and 91% categorical agreement (sensitive, intermediate, resistant) of results, respectively, compared with the reference method. However, both methods demonstrated lower agreement for E. coli-ampicillin/cephalothin combinations than for Gram-positive isolates. In conclusion, the Sensititre and ADD methods had moderate to high diagnostic accuracy and very good essential and categorical agreement for most udder pathogen-antimicrobial combinations and can be readily employed in veterinary diagnostic laboratories. PMID:21270215

  6. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corey, J.P.; Liudahl, J.J.; Young, S.A.

    1991-03-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician.

  7. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    PubMed

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability. (c) 2015 APA, all rights reserved).

  8. Diagnostic methods for insect sting allergy.

    PubMed

    Hamilton, Robert G

    2004-08-01

    This review overviews advances from mid-2002 to the present in the validation and performance methods used in the diagnosis of Hymenoptera venom-induced immediate-type hypersensitivity. The general diagnostic algorithm for insect sting allergy is initially discussed with an examination of the AAAAI's 2003 revised practice parameter guidelines. Changes as a result of a greater recognition of skin test negative systemic reactors include repeat analysis of all testing and acceptance of serology as a complementary diagnostic test to the skin test. Original data examining concordance of venom-specific IgE results produced by the second-generation Pharmacia CAP System with the Johns Hopkins University radioallergosorbent test are presented. Diagnostic performance of honeybee venom-specific IgE assays used in clinical laboratories in North America is discussed using data from the Diagnostic Allergy Proficiency Survey conducted by the College of American Pathologists. Validity of venom-specific IgE antibody in postmortem blood specimens is demonstrated. The utility of alternative in-vivo (provocation) and in-vitro (basophil-based) diagnostic testing methods is critiqued. This overview supports the following conclusions. Improved practice parameter guidelines include serology and skin test as complementary in supporting a positive clinical history during the diagnostic process. Data are provided which support the analytical performance of commercially available venom-specific IgE antibody serology-based assays. Intentional sting challenge in-vivo provocation, in-vitro basophil flow cytometry (CD63, CD203c) based assays, and in-vitro basophil histamine and sulfidoleukotriene release assays have their utility in the study of difficult diagnostic cases, but their use will remain as supplementary, secondary diagnostic tests.

  9. Difference of Diagnostic Rates and Analytical Methods in the Test Positions of Vestibular Evoked Myogenic Potentials

    PubMed Central

    Park, Jeong Mee; Yong, Sang Yeol; Kim, Jong Heon; Kim, Hee; Park, Sang-Yoo

    2014-01-01

    Objective To compare the differences of diagnostic rates, of the two widely used test positions, in measuring vestibular evoked myogenic potentials (VEMP) and selecting the most appropriate analytical method for diagnostic criteria for the patients with vertigo. Methods Thirty-two patients with vertigo were tested in two comparative testing positions: turning the head to the opposite side of the evaluating side and bowing while in seated position, and bowing while in supine positions. Abnormalities were determined by prolonged latency of p13 or n23, shortening of the interpeak latency, and absence of VEMP formation. Results Using the three criteria above for determining abnormalities, both the seated and supine positions showed no significant differences in diagnostic rates, however, the concordance correlation of the two positions was low. When using only the prolonged latency of p13 or n23 in the two positions, diagnostic rates were not significantly different and their concordance correlation was high. On the other hand, using only the shortened interpeak latency in both positions showed no significant difference of diagnostic rates, and the degree of agreement between two positions was low. Conclusion Bowing while in seated position with the head turned in the opposite direction to the area being evaluated is found to be the best VEMP test position due to the consistent level of sternocleidomastoid muscle tension and the high level of compliance. Also, among other diagnostic analysis methods, using prolonged latency of p13 or n23 as the criterion is found to be the most appropriate method of analysis for the VEMP test. PMID:24855617

  10. Diagnostic Tests to Support Late-Stage Control Programs for Schistosomiasis and Soil-Transmitted Helminthiases.

    PubMed

    Hawkins, Kenneth R; Cantera, Jason L; Storey, Helen L; Leader, Brandon T; de Los Santos, Tala

    2016-12-01

    Global efforts to address schistosomiasis and soil-transmitted helminthiases (STH) include deworming programs for school-aged children that are made possible by large-scale drug donations. Decisions on these mass drug administration (MDA) programs currently rely on microscopic examination of clinical specimens to determine the presence of parasite eggs. However, microscopy-based methods are not sensitive to the low-intensity infections that characterize populations that have undergone MDA. Thus, there has been increasing recognition within the schistosomiasis and STH communities of the need for improved diagnostic tools to support late-stage control program decisions, such as when to stop or reduce MDA. Failure to adequately address the need for new diagnostics could jeopardize achievement of the 2020 London Declaration goals. In this report, we assess diagnostic needs and landscape potential solutions and determine appropriate strategies to improve diagnostic testing to support control and elimination programs. Based upon literature reviews and previous input from experts in the schistosomiasis and STH communities, we prioritized two diagnostic use cases for further exploration: to inform MDA-stopping decisions and post-MDA surveillance. To this end, PATH has refined target product profiles (TPPs) for schistosomiasis and STH diagnostics that are applicable to these use cases. We evaluated the limitations of current diagnostic methods with regards to these use cases and identified candidate biomarkers and diagnostics with potential application as new tools. Based on this analysis, there is a need to develop antigen-detecting rapid diagnostic tests (RDTs) with simplified, field-deployable sample preparation for schistosomiasis. Additionally, there is a need for diagnostic tests that are more sensitive than the current methods for STH, which may include either a field-deployable molecular test or a simple, low-cost, rapid antigen-detecting test.

  11. Meta-analysis for the comparison of two diagnostic tests to a common gold standard: A generalized linear mixed model approach.

    PubMed

    Hoyer, Annika; Kuss, Oliver

    2018-05-01

    Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared.

  12. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    PubMed

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  13. Estimation of diagnostic test accuracy without full verification: a review of latent class methods

    PubMed Central

    Collins, John; Huynh, Minh

    2014-01-01

    The performance of a diagnostic test is best evaluated against a reference test that is without error. For many diseases, this is not possible, and an imperfect reference test must be used. However, diagnostic accuracy estimates may be biased if inaccurately verified status is used as the truth. Statistical models have been developed to handle this situation by treating disease as a latent variable. In this paper, we conduct a systematized review of statistical methods using latent class models for estimating test accuracy and disease prevalence in the absence of complete verification. PMID:24910172

  14. Progress in the molecular diagnosis of Lyme disease.

    PubMed

    Ružić-Sabljić, Eva; Cerar, Tjaša

    2017-01-01

    Current laboratory testing of Lyme borreliosis mostly relies on serological methods with known limitations. Diagnostic modalities enabling direct detection of pathogen at the onset of the clinical signs could overcome some of the limitations. Molecular methods detecting borrelial DNA seem to be the ideal solution, although there are some aspects that need to be considered. Areas covered: This review represent summary and discussion of the published data obtained from literature searches from PubMed and The National Library of Medicine (USA) together with our own experience on molecular diagnosis of Lyme disease. Expert commentary: Molecular methods are promising and currently serve as supporting diagnostic testing in Lyme borreliosis. Since the field of molecular diagnostics is under rapid development, molecular testing could become an important diagnostic modality.

  15. Examinations of electron temperature calculation methods in Thomson scattering diagnostics.

    PubMed

    Oh, Seungtae; Lee, Jong Ha; Wi, Hanmin

    2012-10-01

    Electron temperature from Thomson scattering diagnostic is derived through indirect calculation based on theoretical model. χ-square test is commonly used in the calculation, and the reliability of the calculation method highly depends on the noise level of input signals. In the simulations, noise effects of the χ-square test are examined and scale factor test is proposed as an alternative method.

  16. Bivariate random-effects meta-analysis models for diagnostic test accuracy studies using arcsine-based transformations.

    PubMed

    Negeri, Zelalem F; Shaikh, Mateen; Beyene, Joseph

    2018-05-11

    Diagnostic or screening tests are widely used in medical fields to classify patients according to their disease status. Several statistical models for meta-analysis of diagnostic test accuracy studies have been developed to synthesize test sensitivity and specificity of a diagnostic test of interest. Because of the correlation between test sensitivity and specificity, modeling the two measures using a bivariate model is recommended. In this paper, we extend the current standard bivariate linear mixed model (LMM) by proposing two variance-stabilizing transformations: the arcsine square root and the Freeman-Tukey double arcsine transformation. We compared the performance of the proposed methods with the standard method through simulations using several performance measures. The simulation results showed that our proposed methods performed better than the standard LMM in terms of bias, root mean square error, and coverage probability in most of the scenarios, even when data were generated assuming the standard LMM. We also illustrated the methods using two real data sets. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. [Implication of inverse-probability weighting method in the evaluation of diagnostic test with verification bias].

    PubMed

    Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin

    2014-03-01

    To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.

  18. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.

    PubMed

    McInnes, Matthew D F; Moher, David; Thombs, Brett D; McGrath, Trevor A; Bossuyt, Patrick M; Clifford, Tammy; Cohen, Jérémie F; Deeks, Jonathan J; Gatsonis, Constantine; Hooft, Lotty; Hunt, Harriet A; Hyde, Christopher J; Korevaar, Daniël A; Leeflang, Mariska M G; Macaskill, Petra; Reitsma, Johannes B; Rodin, Rachel; Rutjes, Anne W S; Salameh, Jean-Paul; Stevens, Adrienne; Takwoingi, Yemisi; Tonelli, Marcello; Weeks, Laura; Whiting, Penny; Willis, Brian H

    2018-01-23

    Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. The 27-item PRISMA diagnostic test accuracy checklist provides specific guidance for reporting of systematic reviews. The PRISMA diagnostic test accuracy guideline can facilitate the transparent reporting of reviews, and may assist in the evaluation of validity and applicability, enhance replicability of reviews, and make the results from systematic reviews of diagnostic test accuracy studies more useful.

  19. Cheyletiella infestation in the dog: observations on diagnostic methods and clinical signs.

    PubMed

    Saevik, B K; Bredal, W; Ulstein, T L

    2004-10-01

    The aims of this study were to evaluate the ability of diagnostic methods to detect naturally occurring Cheyletiella infestation in dogs, and to quantify and relate the number of mites and eggs present to clinical signs. Privately owned dogs with skin problems were eligible for inclusion in the study. Four diagnostic tests were performed on each dog in the following order: tape impression, hair plucking, skin scraping and vacuum cleaning. Dogs with positive test results for Cheyletiella infestation in at least one of the tests under evaluation were included in the study (n=27). The severity of pruritus and scaling was graded on a four-point fixed scale. The diagnostic findings in vacuum cleaning samples provided a semiquantitative measure of the grade of infestation. The vacuum cleaning test gave a positive test result in all dogs and was significantly more efficient than the other tests evaluated (P<0.01). The number of diagnostic findings varied considerably among the different vacuum samples. No significant relationship between the number of diagnostic findings and severity of clinical signs was detected.

  20. Optimal Combinations of Diagnostic Tests Based on AUC.

    PubMed

    Huang, Xin; Qin, Gengsheng; Fang, Yixin

    2011-06-01

    When several diagnostic tests are available, one can combine them to achieve better diagnostic accuracy. This article considers the optimal linear combination that maximizes the area under the receiver operating characteristic curve (AUC); the estimates of the combination's coefficients can be obtained via a nonparametric procedure. However, for estimating the AUC associated with the estimated coefficients, the apparent estimation by re-substitution is too optimistic. To adjust for the upward bias, several methods are proposed. Among them the cross-validation approach is especially advocated, and an approximated cross-validation is developed to reduce the computational cost. Furthermore, these proposed methods can be applied for variable selection to select important diagnostic tests. The proposed methods are examined through simulation studies and applications to three real examples. © 2010, The International Biometric Society.

  1. Systematic Review of Health Economic Evaluations of Diagnostic Tests in Brazil: How accurate are the results?

    PubMed

    Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho

    2017-08-01

    The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.

  2. The diagnostic plot analysis of artesian aquifers with case studies in Table Mountain Group of South Africa

    NASA Astrophysics Data System (ADS)

    Sun, Xiaobin; Xu, Yongxin; Lin, Lixiang

    2015-05-01

    Parameter estimates of artesian aquifers where piezometric head is above ground level are largely made through free-flowing and recovery tests. The straight-line method proposed by Jacob-Lohman is often used for interpretation of flow rate measured at flowing artesian boreholes. However, the approach fails to interpret the free-flowing test data from two artesian boreholes in the fractured-rock aquifer in Table Mountain Group (TMG) of South Africa. The diagnostic plot method using the reciprocal rate derivative is adapted to evaluate the artesian aquifer properties. The variation of the derivative helps not only identify flow regimes and discern the boundary conditions, but also facilitates conceptualization of the aquifer system and selection of an appropriate model for data interpretation later on. Test data from two free-flowing tests conducted in different sites in TMG are analysed using the diagnostic plot method. Based on the results, conceptual models and appropriate approaches are developed to evaluate the aquifer properties. The advantages and limitations of using the diagnostic plot method on free-flowing test data are discussed.

  3. Quality and Reporting of Diagnostic Accuracy Studies in TB, HIV and Malaria: Evaluation Using QUADAS and STARD Standards

    PubMed Central

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-01-01

    Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases. PMID:19915664

  4. [Current macro-diagnostic trends of forensic medicine in the Czech Republic].

    PubMed

    Frišhons, Jan; Kučerová, Štěpánka; Jurda, Mikoláš; Sokol, Miloš; Vojtíšek, Tomáš; Hejna, Petr

    2017-01-01

    Over the last few years, advanced diagnostic methods have penetrated in the realm of forensic medicine in addition to standard autopsy techniques supported by traditional X-ray examination and macro-diagnostic laboratory tests. Despite the progress of imaging methods, the conventional autopsy has remained basic and essential diagnostic tool in forensic medicine. Postmortem computed tomography and magnetic resonance imaging are far the most progressive modern radio diagnostic methods setting the current trend of virtual autopsies all over the world. Up to now, only two institutes of forensic medicine have available postmortem computed tomography for routine diagnostic purposes in the Czech Republic. Postmortem magnetic resonance is currently unattainable for routine diagnostic use and was employed only for experimental purposes. Photogrammetry is digital method focused primarily on body surface imaging. Recently, the most fruitful results have been yielded from the interdisciplinary cooperation between forensic medicine and forensic anthropology with the implementation of body scanning techniques and 3D printing. Non-invasive and mini-invasive investigative methods such as postmortem sonography and postmortem endoscopy was unsystematically tested for diagnostic performance with good outcomes despite of limitations of these methods in postmortem application. Other futuristic methods, such as the use of a drone to inspect the crime scene are still experimental tools. The authors of the article present a basic overview of the both routinely and experimentally used investigative methods and current macro-diagnostic trends of the forensic medicine in the Czech Republic.

  5. A comparison of diagnostic tests for lactose malabsorption - which one is the best?

    PubMed Central

    2009-01-01

    Background Perceived milk intolerance is a common complaint, and tests for lactose malabsorption (LM) are unreliable. This study assesses the agreement between diagnostic tests for LM and describes the diagnostic properties of the tests. Methods Patients above 18 years of age with suspected LM were included. After oral intake of 25 g lactose, a combined test with measurement of serum glucose (s-glucose) and hydrogen (H2) and methane (CH4) in expired air was performed and symptoms were recorded. In patients with discrepancies between the results, the combined test was repeated and a gene test for lactose non-persistence was added. The diagnosis of LM was based on an evaluation of all tests. The following tests were compared: Increase in H2, CH4, H2+CH4 and H2+CH4x2 in expired air, increase in s-glucose, and symptoms. The agreement was calculated and the diagnostic properties described. Results Sixty patients were included, seven (12%) had LM. The agreement (kappa-values) between the methods varied from 0.25 to 0.91. The best test was the lactose breath test with measurement of the increase in H2 + CH4x2 in expired air. With a cut-off level < 18 ppm, the area under the ROC-curve was 0.967 and sensitivity was 100%. This shows that measurement of CH4 in addition to H2 improves the diagnostic properties of the breath test. Conclusion The agreement between commonly used methods for the diagnosis of LM was unsatisfactory. A lactose breath test with measurement of H2 + CH4x2 in expired air had the best diagnostic properties. PMID:19878587

  6. Nonparametric predictive inference for combining diagnostic tests with parametric copula

    NASA Astrophysics Data System (ADS)

    Muhammad, Noryanti; Coolen, F. P. A.; Coolen-Maturi, T.

    2017-09-01

    Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine and health care. The Receiver Operating Characteristic (ROC) curve is a popular statistical tool for describing the performance of diagnostic tests. The area under the ROC curve (AUC) is often used as a measure of the overall performance of the diagnostic test. In this paper, we interest in developing strategies for combining test results in order to increase the diagnostic accuracy. We introduce nonparametric predictive inference (NPI) for combining two diagnostic test results with considering dependence structure using parametric copula. NPI is a frequentist statistical framework for inference on a future observation based on past data observations. NPI uses lower and upper probabilities to quantify uncertainty and is based on only a few modelling assumptions. While copula is a well-known statistical concept for modelling dependence of random variables. A copula is a joint distribution function whose marginals are all uniformly distributed and it can be used to model the dependence separately from the marginal distributions. In this research, we estimate the copula density using a parametric method which is maximum likelihood estimator (MLE). We investigate the performance of this proposed method via data sets from the literature and discuss results to show how our method performs for different family of copulas. Finally, we briefly outline related challenges and opportunities for future research.

  7. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel ‘V-plot’ methodology to display accuracy values

    PubMed Central

    Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424

  8. An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

    PubMed

    Obuchowski, Nancy A

    2006-02-15

    ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.

  9. Built-In-Test Equipment Requirements Workshop. Workshop Presentation

    DTIC Science & Technology

    1981-08-01

    quantitatively evaluated in test. (2) It is necessary to develop the statistical methods that should be used for predicting and confirming of diagnostic...of different performance levels of BIT peacetime and wartime applications, and the corresponding manpower and other support requirements should be...reports. The scope of the workshop involves the areas of require- ments for built-in-test and diagnostics, and the methods of testing to ensure that the

  10. Compare diagnostic tests using transformation-invariant smoothed ROC curves⋆

    PubMed Central

    Tang, Liansheng; Du, Pang; Wu, Chengqing

    2012-01-01

    Receiver operating characteristic (ROC) curve, plotting true positive rates against false positive rates as threshold varies, is an important tool for evaluating biomarkers in diagnostic medicine studies. By definition, ROC curve is monotone increasing from 0 to 1 and is invariant to any monotone transformation of test results. And it is often a curve with certain level of smoothness when test results from the diseased and non-diseased subjects follow continuous distributions. Most existing ROC curve estimation methods do not guarantee all of these properties. One of the exceptions is Du and Tang (2009) which applies certain monotone spline regression procedure to empirical ROC estimates. However, their method does not consider the inherent correlations between empirical ROC estimates. This makes the derivation of the asymptotic properties very difficult. In this paper we propose a penalized weighted least square estimation method, which incorporates the covariance between empirical ROC estimates as a weight matrix. The resulting estimator satisfies all the aforementioned properties, and we show that it is also consistent. Then a resampling approach is used to extend our method for comparisons of two or more diagnostic tests. Our simulations show a significantly improved performance over the existing method, especially for steep ROC curves. We then apply the proposed method to a cancer diagnostic study that compares several newly developed diagnostic biomarkers to a traditional one. PMID:22639484

  11. Evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia.

    PubMed

    Yimer, Mulat; Hailu, Tadesse; Mulu, Wondemagegn; Abera, Bayeh

    2015-12-26

    Although the sensitivity of Wet mount technique is questionable, it is the major diagnostic technique for routine diagnosis of intestinal parasitosis in Ethiopia. Therefore, the aim of this study was the evaluation performance of diagnostic methods of intestinal parasitosis in school age children in Ethiopia. A cross sectional study was conducted from May to June 2013. Single stool sample was processed for direct, Formol ether concentration (FEC) and Kato Katz methods. The sensitivity and negative predictive value (NPV) of diagnostic tests were calculated in terms of the "Gold" standard method (the combined result of the three methods altogether). A total of 422 school age children were participated in this study. The prevalence of intestinal parasites was high (74.6%) with Kato Katz technique. The sensitivity of Wet mount, FEC and Kato Katz tests against the Gold standard test was 48.9, 63.1 and 93.7%, respectively. Kato Katz technique revealed a better NPV 80.4 (80.1-80.6) as compared to the Wet mount (33.7%) and FEC techniques (41.3%). In this study, the Kato Katz technique outperformed the other two methods but the true values for sensitivity, specificity and diagnostic values are not known. Moreover, it is labor intensive and not easily accessible. Hence, it is preferable to use FEC technique to complement the Wet mount test.

  12. [An evaluation of the effectiveness of laboratory diagnostic methods for brucellosis].

    PubMed

    Gandara, B; Zheludkov, M M; Chernysheva, M I

    1994-01-01

    The diagnostic value of bacteriological and serological methods for the laboratory diagnosis of brucellosis was studied. In the analysis of milk and cheese specimens Brucella cultures were isolated and differentiated as B.melitensis, biovar I, and B.abortus, biovar 4. In 25.6% of cases B.melitensis culture, biovar 1, was isolated from the blood of persons suspected for brucellosis. The isolation of B.melitensis culture from milk showed that this infective agent migrated from small animals to cattle, which was indicative of a high risk of human infection in the state of Zacatecas, Mexico. The comparative evaluation of serological diagnostic methods (the agglutination test in test tubes, Huddleson's slide test, the acidic rose bengal test and the 2-mercaptoethanol test) showed high sensitivity of rapid tests (Huddleson's test and the rose bengal test in 93.7% and 87.9% of cases respectively). The 2-mercaptoethanol test which gave positive results in 63.8% of cases provided additional information characterizing the course of infections process.

  13. Unified Least Squares Methods for the Evaluation of Diagnostic Tests With the Gold Standard

    PubMed Central

    Tang, Liansheng Larry; Yuan, Ao; Collins, John; Che, Xuan; Chan, Leighton

    2017-01-01

    The article proposes a unified least squares method to estimate the receiver operating characteristic (ROC) parameters for continuous and ordinal diagnostic tests, such as cancer biomarkers. The method is based on a linear model framework using the empirically estimated sensitivities and specificities as input “data.” It gives consistent estimates for regression and accuracy parameters when the underlying continuous test results are normally distributed after some monotonic transformation. The key difference between the proposed method and the method of Tang and Zhou lies in the response variable. The response variable in the latter is transformed empirical ROC curves at different thresholds. It takes on many values for continuous test results, but few values for ordinal test results. The limited number of values for the response variable makes it impractical for ordinal data. However, the response variable in the proposed method takes on many more distinct values so that the method yields valid estimates for ordinal data. Extensive simulation studies are conducted to investigate and compare the finite sample performance of the proposed method with an existing method, and the method is then used to analyze 2 real cancer diagnostic example as an illustration. PMID:28469385

  14. Can electronic medical images replace hard-copy film? Defining and testing the equivalence of diagnostic tests.

    PubMed

    Obuchowski, N A

    2001-10-15

    Electronic medical images are an efficient and convenient format in which to display, store and transmit radiographic information. Before electronic images can be used routinely to screen and diagnose patients, however, it must be shown that readers have the same diagnostic performance with this new format as traditional hard-copy film. Currently, there exist no suitable definitions of diagnostic equivalence. In this paper we propose two criteria for diagnostic equivalence. The first criterion ('population equivalence') considers the variability between and within readers, as well as the mean reader performance. This criterion is useful for most applications. The second criterion ('individual equivalence') involves a comparison of the test results for individual patients and is necessary when patients are followed radiographically over time. We present methods for testing both individual and population equivalence. The properties of the proposed methods are assessed in a Monte Carlo simulation study. Data from a mammography screening study is used to illustrate the proposed methods and compare them with results from more conventional methods of assessing equivalence and inter-procedure agreement. Copyright 2001 John Wiley & Sons, Ltd.

  15. Exploration of Analysis Methods for Diagnostic Imaging Tests: Problems with ROC AUC and Confidence Scores in CT Colonography

    PubMed Central

    Mallett, Susan; Halligan, Steve; Collins, Gary S.; Altman, Doug G.

    2014-01-01

    Background Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. Methods In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Results Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. Conclusions The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests. PMID:25353643

  16. Panel-based Genetic Diagnostic Testing for Inherited Eye Diseases is Highly Accurate and Reproducible and More Sensitive for Variant Detection Than Exome Sequencing

    PubMed Central

    Bujakowska, Kinga M.; Sousa, Maria E.; Fonseca-Kelly, Zoë D.; Taub, Daniel G.; Janessian, Maria; Wang, Dan Yi; Au, Elizabeth D.; Sims, Katherine B.; Sweetser, David A.; Fulton, Anne B.; Liu, Qin; Wiggs, Janey L.; Gai, Xiaowu; Pierce, Eric A.

    2015-01-01

    Purpose Next-generation sequencing (NGS) based methods are being adopted broadly for genetic diagnostic testing, but the performance characteristics of these techniques have not been fully defined with regard to test accuracy and reproducibility. Methods We developed a targeted enrichment and NGS approach for genetic diagnostic testing of patients with inherited eye disorders, including inherited retinal degenerations, optic atrophy and glaucoma. In preparation for providing this Genetic Eye Disease (GEDi) test on a CLIA-certified basis, we performed experiments to measure the sensitivity, specificity, reproducibility as well as the clinical sensitivity of the test. Results The GEDi test is highly reproducible and accurate, with sensitivity and specificity for single nucleotide variant detection of 97.9% and 100%, respectively. The sensitivity for variant detection was notably better than the 88.3% achieved by whole exome sequencing (WES) using the same metrics, due to better coverage of targeted genes in the GEDi test compared to commercially available exome capture sets. Prospective testing of 192 patients with IRDs indicated that the clinical sensitivity of the GEDi test is high, with a diagnostic rate of 51%. Conclusion The data suggest that based on quantified performance metrics, selective targeted enrichment is preferable to WES for genetic diagnostic testing. PMID:25412400

  17. Network meta-analysis of diagnostic test accuracy studies identifies and ranks the optimal diagnostic tests and thresholds for health care policy and decision-making.

    PubMed

    Owen, Rhiannon K; Cooper, Nicola J; Quinn, Terence J; Lees, Rosalind; Sutton, Alex J

    2018-07-01

    Network meta-analyses (NMA) have extensively been used to compare the effectiveness of multiple interventions for health care policy and decision-making. However, methods for evaluating the performance of multiple diagnostic tests are less established. In a decision-making context, we are often interested in comparing and ranking the performance of multiple diagnostic tests, at varying levels of test thresholds, in one simultaneous analysis. Motivated by an example of cognitive impairment diagnosis following stroke, we synthesized data from 13 studies assessing the efficiency of two diagnostic tests: Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA), at two test thresholds: MMSE <25/30 and <27/30, and MoCA <22/30 and <26/30. Using Markov chain Monte Carlo (MCMC) methods, we fitted a bivariate network meta-analysis model incorporating constraints on increasing test threshold, and accounting for the correlations between multiple test accuracy measures from the same study. We developed and successfully fitted a model comparing multiple tests/threshold combinations while imposing threshold constraints. Using this model, we found that MoCA at threshold <26/30 appeared to have the best true positive rate, whereas MMSE at threshold <25/30 appeared to have the best true negative rate. The combined analysis of multiple tests at multiple thresholds allowed for more rigorous comparisons between competing diagnostics tests for decision making. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Using Meta-Analysis to Inform the Design of Subsequent Studies of Diagnostic Test Accuracy

    ERIC Educational Resources Information Center

    Hinchliffe, Sally R.; Crowther, Michael J.; Phillips, Robert S.; Sutton, Alex J.

    2013-01-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial…

  19. Development of a diagnostic test set to assess agreement in breast pathology: practical application of the Guidelines for Reporting Reliability and Agreement Studies (GRRAS).

    PubMed

    Oster, Natalia V; Carney, Patricia A; Allison, Kimberly H; Weaver, Donald L; Reisch, Lisa M; Longton, Gary; Onega, Tracy; Pepe, Margaret; Geller, Berta M; Nelson, Heidi D; Ross, Tyler R; Tosteson, Aanna N A; Elmore, Joann G

    2013-02-05

    Diagnostic test sets are a valuable research tool that contributes importantly to the validity and reliability of studies that assess agreement in breast pathology. In order to fully understand the strengths and weaknesses of any agreement and reliability study, however, the methods should be fully reported. In this paper we provide a step-by-step description of the methods used to create four complex test sets for a study of diagnostic agreement among pathologists interpreting breast biopsy specimens. We use the newly developed Guidelines for Reporting Reliability and Agreement Studies (GRRAS) as a basis to report these methods. Breast tissue biopsies were selected from the National Cancer Institute-funded Breast Cancer Surveillance Consortium sites. We used a random sampling stratified according to woman's age (40-49 vs. ≥50), parenchymal breast density (low vs. high) and interpretation of the original pathologist. A 3-member panel of expert breast pathologists first independently interpreted each case using five primary diagnostic categories (non-proliferative changes, proliferative changes without atypia, atypical ductal hyperplasia, ductal carcinoma in situ, and invasive carcinoma). When the experts did not unanimously agree on a case diagnosis a modified Delphi method was used to determine the reference standard consensus diagnosis. The final test cases were stratified and randomly assigned into one of four unique test sets. We found GRRAS recommendations to be very useful in reporting diagnostic test set development and recommend inclusion of two additional criteria: 1) characterizing the study population and 2) describing the methods for reference diagnosis, when applicable.

  20. Determination of the optimal cutoff value for a serological assay: an example using the Johne's Absorbed EIA.

    PubMed Central

    Ridge, S E; Vizard, A L

    1993-01-01

    Traditionally, in order to improve diagnostic accuracy, existing tests have been replaced with newly developed diagnostic tests with superior sensitivity and specificity. However, it is possible to improve existing tests by altering the cutoff value chosen to distinguish infected individuals from uninfected individuals. This paper uses data obtained from an investigation of the operating characteristics of the Johne's Absorbed EIA to demonstrate a method of determining a preferred cutoff value from several potentially useful cutoff settings. A method of determining the financial gain from using the preferred rather than the current cutoff value and a decision analysis method to assist in determining the optimal cutoff value when critical population parameters are not known with certainty are demonstrated. The results of this study indicate that the currently recommended cutoff value for the Johne's Absorbed EIA is only close to optimal when the disease prevalence is very low and false-positive test results are deemed to be very costly. In other situations, there were considerable financial advantages to using cutoff values calculated to maximize the benefit of testing. It is probable that the current cutoff values for other diagnostic tests may not be the most appropriate for every testing situation. This paper offers methods for identifying the cutoff value that maximizes the benefit of medical and veterinary diagnostic tests. PMID:8501227

  1. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    PubMed

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  2. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    PubMed

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  3. Adjusting for partial verification or workup bias in meta-analyses of diagnostic accuracy studies.

    PubMed

    de Groot, Joris A H; Dendukuri, Nandini; Janssen, Kristel J M; Reitsma, Johannes B; Brophy, James; Joseph, Lawrence; Bossuyt, Patrick M M; Moons, Karel G M

    2012-04-15

    A key requirement in the design of diagnostic accuracy studies is that all study participants receive both the test under evaluation and the reference standard test. For a variety of practical and ethical reasons, sometimes only a proportion of patients receive the reference standard, which can bias the accuracy estimates. Numerous methods have been described for correcting this partial verification bias or workup bias in individual studies. In this article, the authors describe a Bayesian method for obtaining adjusted results from a diagnostic meta-analysis when partial verification or workup bias is present in a subset of the primary studies. The method corrects for verification bias without having to exclude primary studies with verification bias, thus preserving the main advantages of a meta-analysis: increased precision and better generalizability. The results of this method are compared with the existing methods for dealing with verification bias in diagnostic meta-analyses. For illustration, the authors use empirical data from a systematic review of studies of the accuracy of the immunohistochemistry test for diagnosis of human epidermal growth factor receptor 2 status in breast cancer patients.

  4. Rapid molecular diagnostics for multi-drug resistant tuberculosis in India.

    PubMed

    Ramachandran, Rajeswari; Muniyandi, M

    2018-03-01

    Rapid molecular diagnostic methods help in the detection of TB and Rifampicin resistance. These methods detect TB early, are accurate and play a crucial role in reducing the burden of drug resistant tuberculosis. Areas covered: This review analyses rapid molecular diagnostic tools used in the diagnosis of MDR-TB in India, such as the Line Probe Assay and GeneXpert. We have discussed the burden of MDR-TB and the impact of recent diagnostic tools on case detection and treatment outcomes. This review also discusses the costs involved in establishing these new techniques in India. Expert commentary: Molecular methods have considerable advantages for the programmatic management of drug resistant TB. These include speed, standardization of testing, potentially high throughput and reduced laboratory biosafety requirements. There is a desperate need for India to adopt modern, rapid, molecular tools with point-of-care tests being currently evaluated. New molecular diagnostic tests appear to be cost effective and also help in detecting missing cases. There is enough evidence to support the scaling up of these new tools in India.

  5. Diagnostic sensitivity and specificity of a participatory disease surveillance method for highly pathogenic avian influenza in household chicken flocks in Indonesia.

    PubMed

    Robyn, M; Priyono, W B; Kim, L M; Brum, E

    2012-06-01

    A study was conducted to assess the diagnostic sensitivity and specificity of a disease surveillance method for diagnosis of highly pathogenic avian influenza (HPAI) outbreaks in household chicken flocks used by participatory disease surveillance (PDS) teams in Yogyakarta Province, Indonesia. The Government of Indonesia, in partnership with the Food and Agriculture Organization of the United Nations, has implemented a PDS method for the detection of HPAI outbreaks in poultry since 2006. The PDS method in Indonesia utilizes both a clinical case definition (CD) and the result of a commercial rapid antigen test kit Yogyakarta 55611, to diagnose HPAI outbreaks, primarily in backyard chicken flocks. The following diagnostic sensitivities and specificities were obtained relative to real-time reverse transcription-PCR as the gold standard diagnostic test: 1) 89% sensitivity (CI95: 75%-97%) and 96% specificity (CI95: 89%-99%) for the PDS CD alone; 2) 86% sensitivity (CI95: 71%-95%) and 99% specificity (CI95: 94%-100%) for the rapid antigen test alone; and 3) 84% sensitivity (CI95: 68%-94%) and 100% specificity (CI95: 96%-100%) for the PDS CD result combined with the rapid antigen test result. Based on these results, HPAI outbreaks in extensively raised household chickens can be diagnosed with sufficient sensitivity and specificity using the PDS method as implemented in Indonesia. Subject to further field evaluation, data from this study suggest that the diagnostic sensitivity of the PDS method may be improved by expanding the PDS CD to include more possible clinical presentations of HPAI and by increasing the number of rapid antigen tests to three different birds with HPAI-compatible signs of same flock.

  6. Propulsion Diagnostic Method Evaluation Strategy (ProDiMES) User's Guide

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2010-01-01

    This report is a User's Guide for the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES). ProDiMES is a standard benchmarking problem and a set of evaluation metrics to enable the comparison of candidate aircraft engine gas path diagnostic methods. This Matlab (The Mathworks, Inc.) based software tool enables users to independently develop and evaluate diagnostic methods. Additionally, a set of blind test case data is also distributed as part of the software. This will enable the side-by-side comparison of diagnostic approaches developed by multiple users. The Users Guide describes the various components of ProDiMES, and provides instructions for the installation and operation of the tool.

  7. A hybrid model for combining case-control and cohort studies in systematic reviews of diagnostic tests

    PubMed Central

    Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao

    2014-01-01

    Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179

  8. A Research Agenda for Malaria Eradication: Diagnoses and Diagnostics

    PubMed Central

    2011-01-01

    Many of malaria's signs and symptoms are indistinguishable from those of other febrile diseases. Detection of the presence of Plasmodium parasites is essential, therefore, to guide case management. Improved diagnostic tools are required to enable targeted treatment of infected individuals. In addition, field-ready diagnostic tools for mass screening and surveillance that can detect asymptomatic infections of very low parasite densities are needed to monitor transmission reduction and ensure elimination. Antibody-based tests for infection and novel methods based on biomarkers need further development and validation, as do methods for the detection and treatment of Plasmodium vivax. Current rapid diagnostic tests targeting P. vivax are generally less effective than those targeting Plasmodium falciparum. Moreover, because current drugs for radical cure may cause serious side effects in patients with glucose-6-phosphate dehydrogenase (G6PD) deficiency, more information is needed on the distribution of G6PD-deficiency variants as well as tests to identify at-risk individuals. Finally, in an environment of very low or absent malaria transmission, sustaining interest in elimination and maintaining resources will become increasingly important. Thus, research is required into the context in which malaria diagnostic tests are used, into diagnostics for other febrile diseases, and into the integration of these tests into health systems. PMID:21311583

  9. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    PubMed

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  10. Methods specification for diagnostic test accuracy studies in fine-needle aspiration cytology: a survey of reporting practice.

    PubMed

    Schmidt, Robert L; Factor, Rachel E; Affolter, Kajsa E; Cook, Joshua B; Hall, Brian J; Narra, Krishna K; Witt, Benjamin L; Wilson, Andrew R; Layfield, Lester J

    2012-01-01

    Diagnostic test accuracy (DTA) studies on fine-needle aspiration cytology (FNAC) often show considerable variability in diagnostic accuracy between study centers. Many factors affect the accuracy of FNAC. A complete description of the testing parameters would help make valid comparisons between studies and determine causes of performance variation. We investigated the manner in which test conditions are specified in FNAC DTA studies to determine which parameters are most commonly specified and the frequency with which they are specified and to see whether there is significant variability in reporting practice. We identified 17 frequently reported test parameters and found significant variation in the reporting of these test specifications across studies. On average, studies reported 5 of the 17 items that would be required to specify the test conditions completely. A more complete and standardized reporting of methods, perhaps by means of a checklist, would improve the interpretation of FNAC DTA studies.

  11. Comparison of four diagnostic tests for the identification of serum antibodies in small ruminants infected with Mycoplasma agalactiae.

    PubMed

    Kittelberger, R; O'Keefe, J S; Meynell, R; Sewell, M; Rosati, S; Lambert, M; Dufour, P; Pépin, M

    2006-02-01

    To determine the diagnostic capability of a newly developed Western blot (WB) assay for the detection of serum antibodies against Mycoplasma agalactiae compared with conventional serological tests, and to identify the best test for routine diagnostic use. The serological test methods used were: two commercial indirect enzyme-linked immunosorbent assays (ELISA), viz ELISA-1, using a bacterial antigen preparation, and ELISA-2, using a recombinant protein (lipoprotein p48) antigen; the complement fixation test (CFT); and a newly developed WB assay, the latter both using a bacterial antigen preparation. Thirty sera from goats infected with M. agalactiae and 97 sera from non-infected sheep were tested using all four methods. Staining patterns in the WB were quite variable. An immuno-dominant band of 41 kDa was detected in 63% of sera from infected animals. The same band also appeared, although mostly very weakly, in 10% of sera from non-infected animals. When suspicious or very weak reactors were omitted, the diagnostic sensitivity (DSE) and diagnostic specificity (DSP), respectively, for the four assays were: WB=56.7%, 97.9%; ELISA-1=76.7%, 99.0%; ELISA-2=56.7%, 100%; and CFT=40.0%, 94.8%. ELISA-1 performed best in this comparison. While the WB can be used, it did not have a technical advantage over the ELISA. The CFT should be discouraged as the primary screening method for contagious agalactia and should be replaced by ELISA-1. Results from this study confirm that serological test methods for contagious agalactia are useful for the detection of infected flocks but will not detect every individual infected animal.

  12. AST Combustion Workshop: Diagnostics Working Group Report

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Hanson, Ronald K.

    1996-01-01

    A workshop was convened under NASA's Advanced Subsonics Technologies (AST) Program. Many of the principal combustion diagnosticians from industry, academia, and government laboratories were assembled in the Diagnostics/Testing Subsection of this workshop to discuss the requirements and obstacles to the successful implementation of advanced diagnostic techniques to the test environment of the proposed AST combustor. The participants, who represented the major relevant areas of advanced diagnostic methods currently applied to combustion and related fields, first established the anticipated AST combustor flowfield conditions. Critical flow parameters were then examined and prioritized as to their importance to combustor/fuel injector design and manufacture, environmental concerns, and computational interests. Diagnostic techniques were then evaluated in terms of current status, merits and obstacles for each flow parameter. All evaluations are presented in tabular form and recommendations are made on the best-suited diagnostic method to implement for each flow parameter in order of applicability and intrinsic value.

  13. Quality and reporting of diagnostic accuracy studies in TB, HIV and malaria: evaluation using QUADAS and STARD standards.

    PubMed

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-11-13

    Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004-2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.

  14. Autoimmune diagnostics: the technology, the strategy and the clinical governance.

    PubMed

    Bizzaro, Nicola; Tozzoli, Renato; Villalta, Danilo

    2015-02-01

    In recent years, there has been a profound change in autoimmune diagnostics. From long, tiring and inaccurate manual methods, the art of diagnostics has turned to modern, rapid and automated technology. New antibody tests have been developed, and almost all autoimmune diseases now have some specific diagnostic markers. The current need to make the most of available economic and human resources has led to the production of diagnostic algorithms and guidelines designated for optimal strategic use of the tests and to increase the diagnostic appropriateness. An important role in this scenario was assumed by the laboratory autoimmunologist, whose task is not only to govern the analytical phase, but also to help clinicians in correctly choosing the most suitable test for each clinical situation and provide consultancy support. In this review, we summarize recent advances in technology, describe the diagnostic strategies and highlight the current role of the laboratory autoimmunologist in the clinical governance of autoimmune diagnostics.

  15. Diagnostic test for prenatal identification of Down's syndrome and mental retardation and gene therapy therefor

    DOEpatents

    Smith, Desmond J.; Rubin, Edward M.

    2000-01-01

    A a diagnostic test useful for prenatal identification of Down syndrome and mental retardation. A method for gene therapy for correction and treatment of Down syndrome. DYRK gene involved in the ability to learn. A method for diagnosing Down's syndrome and mental retardation and an assay therefor. A pharmaceutical composition for treatment of Down's syndrome mental retardation.

  16. Nested-PCR and a new ELISA-based NovaLisa test kit for malaria diagnosis in an endemic area of Thailand.

    PubMed

    Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara

    2014-08-01

    Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

  17. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  18. Molecular diagnostic methods for invasive fungal disease: the horizon draws nearer?

    PubMed

    Halliday, C L; Kidd, S E; Sorrell, T C; Chen, S C-A

    2015-04-01

    Rapid, accurate diagnostic laboratory tests are needed to improve clinical outcomes of invasive fungal disease (IFD). Traditional direct microscopy, culture and histological techniques constitute the 'gold standard' against which newer tests are judged. Molecular diagnostic methods, whether broad-range or fungal-specific, have great potential to enhance sensitivity and speed of IFD diagnosis, but have varying specificities. The use of PCR-based assays, DNA sequencing, and other molecular methods including those incorporating proteomic approaches such as matrix-assisted laser desorption ionisation-time of flight mass spectroscopy (MALDI-TOF MS) have shown promising results. These are used mainly to complement conventional methods since they require standardisation before widespread implementation can be recommended. None are incorporated into diagnostic criteria for defining IFD. Commercial assays may assist standardisation. This review provides an update of molecular-based diagnostic approaches applicable to biological specimens and fungal cultures in microbiology laboratories. We focus on the most common pathogens, Candida and Aspergillus, and the mucormycetes. The position of molecular-based approaches in the detection of azole and echinocandin antifungal resistance is also discussed.

  19. Diagnostics of Polymer Composite Materials and Analysis of Their Production Technology by Using the Method of Acoustic Emission

    NASA Astrophysics Data System (ADS)

    Bashkov, O. V.; Protsenko, A. E.; Bryanskii, A. A.; Romashko, R. V.

    2017-09-01

    The strength properties of glass-fiber-reinforced plastics produced by vacuum and vacuum autoclave molding techniques are studied. Based on acoustic emission data, a method of diagnostic and prediction of the bearing capacity of polymer composite materials by using data from three-point bending tests is developed. The method is based on evaluating changes in the exponent of a power function relating the total acoustic emission to the test stress.

  20. Opportunities for Improved Serodiagnosis of Human Tuberculosis, Bovine Tuberculosis, and Paratuberculosis

    PubMed Central

    Wadhwa, Ashutosh; Hickling, Graham J.; Eda, Shigetoshi

    2012-01-01

    Mycobacterial infections—tuberculosis (TB), bovine tuberculosis (bTB), and Johne's disease (JD)—are major infectious diseases of both human and animals. Methods presently in use for diagnosis of mycobacterial infections include bacterial culture, nucleic acid amplification, tuberculin skin test, interferon-γ assay, and serology. Serological tests have several advantages over other methods, including short turn-around time, relatively simple procedures, and low cost. However, current serodiagnostic methods for TB, bTB and JD exhibit low sensitivity and/or specificity. Recent studies that have aimed to develop improved serodiagnostic tests have mostly focused on identifying useful species-specific protein antigens. A review of recent attempts to improve diagnostic test performance indicates that the use of multiple antigens can improve the accuracy of serodiagnosis of these mycobacterial diseases. Mycobacteria also produce a variety of species-specific nonprotein molecules; however, only a few such molecules (e.g., cord factor and lipoarabinomannan) have so far been evaluated for their effectiveness as diagnostic antigens. For TB and bTB, there has been recent progress in developing laboratory-free diagnostic methods. New technologies such as microfluidics and “Lab-on-Chip” are examples of promising new technologies that can underpin development of laboratory-free diagnostic devices for these mycobacterial infections. PMID:22720192

  1. Mutual Information Item Selection Method in Cognitive Diagnostic Computerized Adaptive Testing with Short Test Length

    ERIC Educational Resources Information Center

    Wang, Chun

    2013-01-01

    Cognitive diagnostic computerized adaptive testing (CD-CAT) purports to combine the strengths of both CAT and cognitive diagnosis. Cognitive diagnosis models aim at classifying examinees into the correct mastery profile group so as to pinpoint the strengths and weakness of each examinee whereas CAT algorithms choose items to determine those…

  2. Malaria surveillance in the Democratic Republic of the Congo: comparison of microscopy, PCR, and rapid diagnostic test.

    PubMed

    Doctor, Stephanie M; Liu, Yunhao; Whitesell, Amy; Thwai, Kyaw L; Taylor, Steve M; Janko, Mark; Emch, Michael; Kashamuka, Melchior; Muwonga, Jérémie; Tshefu, Antoinette; Meshnick, Steven R

    2016-05-01

    Malaria surveillance is critical for control efforts, but diagnostic methods frequently disagree. Here, we compare microscopy, PCR, and a rapid diagnostic test in 7137 samples from children in the Democratic Republic of the Congo using latent class analysis. PCR had the highest sensitivity (94.6%) and microscopy had the lowest (76.7%). Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Modeling companion diagnostics in economic evaluations of targeted oncology therapies: systematic review and methodological checklist.

    PubMed

    Doble, Brett; Tan, Marcus; Harris, Anthony; Lorgelly, Paula

    2015-02-01

    The successful use of a targeted therapy is intrinsically linked to the ability of a companion diagnostic to correctly identify patients most likely to benefit from treatment. The aim of this study was to review the characteristics of companion diagnostics that are of importance for inclusion in an economic evaluation. Approaches for including these characteristics in model-based economic evaluations are compared with the intent to describe best practice methods. Five databases and government agency websites were searched to identify model-based economic evaluations comparing a companion diagnostic and subsequent treatment strategy to another alternative treatment strategy with model parameters for the sensitivity and specificity of the companion diagnostic (primary synthesis). Economic evaluations that limited model parameters for the companion diagnostic to only its cost were also identified (secondary synthesis). Quality was assessed using the Quality of Health Economic Studies instrument. 30 studies were included in the review (primary synthesis n = 12; secondary synthesis n = 18). Incremental cost-effectiveness ratios may be lower when the only parameter for the companion diagnostic included in a model is the cost of testing. Incorporating the test's accuracy in addition to its cost may be a more appropriate methodological approach. Altering the prevalence of the genetic biomarker, specific population tested, type of test, test accuracy and timing/sequence of multiple tests can all impact overall model results. The impact of altering a test's threshold for positivity is unknown as it was not addressed in any of the included studies. Additional quality criteria as outlined in our methodological checklist should be considered due to the shortcomings of standard quality assessment tools in differentiating studies that incorporate important test-related characteristics and those that do not. There is a need to refine methods for incorporating the characteristics of companion diagnostics into model-based economic evaluations to ensure consistent and transparent reimbursement decisions are made.

  4. Developing energy and momentum conceptual survey (EMCS) with four-tier diagnostic test items

    NASA Astrophysics Data System (ADS)

    Afif, Nur Faadhilah; Nugraha, Muhammad Gina; Samsudin, Achmad

    2017-05-01

    Students' conceptions of work and energy are important to support the learning process in the classroom. For that reason, a diagnostic test instrument is needed to diagnose students' conception of work and energy. As a result, the researcher decided to develop Energy and Momentum Conceptual Survey (EMCS) instrument test into four-tier test diagnostic items. The purpose of this research is organized as the first step of four-tier test-formatted EMCS development as one of diagnostic test instruments on work and Energy. The research method used the 4D model (Defining, Designing, Developing and Disseminating). The instrument developed has been tested to 39 students in one of Senior High Schools. The resulting research showed that four-tier test-formatted EMCS is able to diagnose students' conception level of work and energy concept. It can be concluded that the development of four-tier test-formatted EMCS is one of potential diagnostic test instruments that able to obtain the category of students who understand concepts, misconceptions and do not understand about Work and Energy concept at all.

  5. Improved diagnostic yield compared with targeted gene sequencing panels suggests a role for whole-genome sequencing as a first-tier genetic test

    PubMed Central

    Lionel, Anath C; Costain, Gregory; Monfared, Nasim; Walker, Susan; Reuter, Miriam S; Hosseini, S Mohsen; Thiruvahindrapuram, Bhooma; Merico, Daniele; Jobling, Rebekah; Nalpathamkalam, Thomas; Pellecchia, Giovanna; Sung, Wilson W L; Wang, Zhuozhi; Bikangaga, Peter; Boelman, Cyrus; Carter, Melissa T; Cordeiro, Dawn; Cytrynbaum, Cheryl; Dell, Sharon D; Dhir, Priya; Dowling, James J; Heon, Elise; Hewson, Stacy; Hiraki, Linda; Inbar-Feigenberg, Michal; Klatt, Regan; Kronick, Jonathan; Laxer, Ronald M; Licht, Christoph; MacDonald, Heather; Mercimek-Andrews, Saadet; Mendoza-Londono, Roberto; Piscione, Tino; Schneider, Rayfel; Schulze, Andreas; Silverman, Earl; Siriwardena, Komudi; Snead, O Carter; Sondheimer, Neal; Sutherland, Joanne; Vincent, Ajoy; Wasserman, Jonathan D; Weksberg, Rosanna; Shuman, Cheryl; Carew, Chris; Szego, Michael J; Hayeems, Robin Z; Basran, Raveen; Stavropoulos, Dimitri J; Ray, Peter N; Bowdin, Sarah; Meyn, M Stephen; Cohn, Ronald D; Scherer, Stephen W; Marshall, Christian R

    2018-01-01

    Purpose Genetic testing is an integral diagnostic component of pediatric medicine. Standard of care is often a time-consuming stepwise approach involving chromosomal microarray analysis and targeted gene sequencing panels, which can be costly and inconclusive. Whole-genome sequencing (WGS) provides a comprehensive testing platform that has the potential to streamline genetic assessments, but there are limited comparative data to guide its clinical use. Methods We prospectively recruited 103 patients from pediatric non-genetic subspecialty clinics, each with a clinical phenotype suggestive of an underlying genetic disorder, and compared the diagnostic yield and coverage of WGS with those of conventional genetic testing. Results WGS identified diagnostic variants in 41% of individuals, representing a significant increase over conventional testing results (24% P = 0.01). Genes clinically sequenced in the cohort (n = 1,226) were well covered by WGS, with a median exonic coverage of 40 × ±8 × (mean ±SD). All the molecular diagnoses made by conventional methods were captured by WGS. The 18 new diagnoses made with WGS included structural and non-exonic sequence variants not detectable with whole-exome sequencing, and confirmed recent disease associations with the genes PIGG, RNU4ATAC, TRIO, and UNC13A. Conclusion WGS as a primary clinical test provided a higher diagnostic yield than conventional genetic testing in a clinically heterogeneous cohort. PMID:28771251

  6. Improved diagnostic yield compared with targeted gene sequencing panels suggests a role for whole-genome sequencing as a first-tier genetic test.

    PubMed

    Lionel, Anath C; Costain, Gregory; Monfared, Nasim; Walker, Susan; Reuter, Miriam S; Hosseini, S Mohsen; Thiruvahindrapuram, Bhooma; Merico, Daniele; Jobling, Rebekah; Nalpathamkalam, Thomas; Pellecchia, Giovanna; Sung, Wilson W L; Wang, Zhuozhi; Bikangaga, Peter; Boelman, Cyrus; Carter, Melissa T; Cordeiro, Dawn; Cytrynbaum, Cheryl; Dell, Sharon D; Dhir, Priya; Dowling, James J; Heon, Elise; Hewson, Stacy; Hiraki, Linda; Inbar-Feigenberg, Michal; Klatt, Regan; Kronick, Jonathan; Laxer, Ronald M; Licht, Christoph; MacDonald, Heather; Mercimek-Andrews, Saadet; Mendoza-Londono, Roberto; Piscione, Tino; Schneider, Rayfel; Schulze, Andreas; Silverman, Earl; Siriwardena, Komudi; Snead, O Carter; Sondheimer, Neal; Sutherland, Joanne; Vincent, Ajoy; Wasserman, Jonathan D; Weksberg, Rosanna; Shuman, Cheryl; Carew, Chris; Szego, Michael J; Hayeems, Robin Z; Basran, Raveen; Stavropoulos, Dimitri J; Ray, Peter N; Bowdin, Sarah; Meyn, M Stephen; Cohn, Ronald D; Scherer, Stephen W; Marshall, Christian R

    2018-04-01

    PurposeGenetic testing is an integral diagnostic component of pediatric medicine. Standard of care is often a time-consuming stepwise approach involving chromosomal microarray analysis and targeted gene sequencing panels, which can be costly and inconclusive. Whole-genome sequencing (WGS) provides a comprehensive testing platform that has the potential to streamline genetic assessments, but there are limited comparative data to guide its clinical use.MethodsWe prospectively recruited 103 patients from pediatric non-genetic subspecialty clinics, each with a clinical phenotype suggestive of an underlying genetic disorder, and compared the diagnostic yield and coverage of WGS with those of conventional genetic testing.ResultsWGS identified diagnostic variants in 41% of individuals, representing a significant increase over conventional testing results (24%; P = 0.01). Genes clinically sequenced in the cohort (n = 1,226) were well covered by WGS, with a median exonic coverage of 40 × ±8 × (mean ±SD). All the molecular diagnoses made by conventional methods were captured by WGS. The 18 new diagnoses made with WGS included structural and non-exonic sequence variants not detectable with whole-exome sequencing, and confirmed recent disease associations with the genes PIGG, RNU4ATAC, TRIO, and UNC13A.ConclusionWGS as a primary clinical test provided a higher diagnostic yield than conventional genetic testing in a clinically heterogeneous cohort.

  7. Developing a new diagnostic algorithm for human papilloma virus associated oropharyngeal carcinoma: an investigation of HPV DNA assays.

    PubMed

    Cohen, Natasha; Gupta, Michael; Doerwald-Munoz, Lilian; Jang, Dan; Young, James Edward Massey; Archibald, Stuart; Jackson, Bernard; Lee, Jenny; Chernesky, Max

    2017-02-13

    Human papilloma virus (HPV) has been implicated in the development of a large proportion of oropharyngeal squamous cell carcinoma (OPSCC). Current techniques used to diagnose HPV etiology require histopathologic analysis. We aim to investigate the diagnostic accuracy of a new application non-histopathologic diagnostic tests to help assist diagnosis of HPV-related oropharyngeal tumors. Patients with OPSCC with nodal metastasis were consecutively recruited from a multidisciplinary cancer clinic. Appropriate samples were collected and analyzed. The various tests examined included COBAS® 4800, Cervista® HR and Genotyping. These tests were compared to p16 staining, which was used as the diagnostic standard. StataIC 14.2 was used to perform analysis, including sensitivity, specificity and receiver operator characteristic [ROC] curves. The COBAS® FNA (area under ROC 0.863) and saliva (area under ROC 0.847) samples performed well in diagnosing HPV positive and negative tumors. Samples tested with Cervista® did not corroborate p16 status reliably. We were able to increase the diagnostic yield of the COBAS® FNA samples by applying the results of the saliva test to negative FNA samples which correctly identified 11 additional p16 positive tumors (area under ROC 0.915). Surrogate testing for HPV using alternate methods is feasible and closely predicts the results of standard diagnostic methods. In the future, these could minimize invasive procedures for diagnosing HPV-related oropharyngeal cancer, but also help to diagnose and treat patients with unknown primaries.

  8. Image processing and machine learning for fully automated probabilistic evaluation of medical images.

    PubMed

    Sajn, Luka; Kukar, Matjaž

    2011-12-01

    The paper presents results of our long-term study on using image processing and data mining methods in a medical imaging. Since evaluation of modern medical images is becoming increasingly complex, advanced analytical and decision support tools are involved in integration of partial diagnostic results. Such partial results, frequently obtained from tests with substantial imperfections, are integrated into ultimate diagnostic conclusion about the probability of disease for a given patient. We study various topics such as improving the predictive power of clinical tests by utilizing pre-test and post-test probabilities, texture representation, multi-resolution feature extraction, feature construction and data mining algorithms that significantly outperform medical practice. Our long-term study reveals three significant milestones. The first improvement was achieved by significantly increasing post-test diagnostic probabilities with respect to expert physicians. The second, even more significant improvement utilizes multi-resolution image parametrization. Machine learning methods in conjunction with the feature subset selection on these parameters significantly improve diagnostic performance. However, further feature construction with the principle component analysis on these features elevates results to an even higher accuracy level that represents the third milestone. With the proposed approach clinical results are significantly improved throughout the study. The most significant result of our study is improvement in the diagnostic power of the whole diagnostic process. Our compound approach aids, but does not replace, the physician's judgment and may assist in decisions on cost effectiveness of tests. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  9. A New Method with General Diagnostic Utility for the Calculation of Immunoglobulin G Avidity

    PubMed Central

    Korhonen, Maria H.; Brunstein, John; Haario, Heikki; Katnikov, Alexei; Rescaldani, Roberto; Hedman, Klaus

    1999-01-01

    The reference method for immunoglobulin G (IgG) avidity determination includes reagent-consuming serum titration. Aiming at better IgG avidity diagnostics, we applied a logistic model for the reproduction of antibody titration curves. This method was tested with well-characterized serum panels for cytomegalovirus, Epstein-Barr virus, rubella virus, parvovirus B19, and Toxoplasma gondii. This approach for IgG avidity calculation is generally applicable and attains the diagnostic performance of the reference method while being less laborious and twice as cost-effective. PMID:10473525

  10. Recent advances in tuberculosis diagnostics in resource-limited settings.

    PubMed

    Seki, Mitsuko; Kim, Chang-Ki; Hayakawa, Satoshi; Mitarai, Satoshi

    2018-04-19

    Smear-negative and drug-resistant cases of tuberculosis (TB) disease necessitate the development of new diagnostic methods, especially in resource-limited settings. To improve the current TB situations, sensitive and specific TB point-of-care tests (POCTs) should be developed. This review addresses the current status of TB, novel diagnostic methodologies for TB, and the impact of those new diagnostics on TB control in such situations. Moreover, the perspective of TB management based on laboratory examinations is described. Smear microscopy with sputum samples is the only laboratory examination available in many resource-limited settings and is still used globally. Several nucleic acid amplification tests (NATs) have been developed. The World Health Organization (WHO) endorsed novel diagnostics based on NATs and updated their definition of a bacteriologically confirmed case requiring the biological specimen to be positive by smear microscopy, culture, or the WHO-recommended rapid diagnostic protocols. The use of new diagnostics increased the number of bacteriologically confirmed TB cases. Novel diagnostics are now available, but their sensitivity is still lower than that of conventional liquid culture method. To address the increasing incidence of TB, more resources including novel diagnostics as POCTs with higher sensitivity must be allocated to healthcare systems.

  11. Trichinella diagnostics and control: mandatory and best practices for ensuring food safety.

    PubMed

    Gajadhar, Alvin A; Pozio, Edoardo; Gamble, H Ray; Nöckler, Karsten; Maddox-Hyttel, Charlotte; Forbes, Lorry B; Vallée, Isabelle; Rossi, Patrizia; Marinculić, Albert; Boireau, Pascal

    2009-02-23

    Because of its role in human disease, there are increasing global requirements for reliable diagnostic and control methods for Trichinella in food animals to ensure meat safety and to facilitate trade. Consequently, there is a need for standardization of methods, programs, and best practices used in the control of Trichinella and trichinellosis. This review article describes the biology and epidemiology of Trichinella, and describes recommended test methods as well as modified and optimized procedures that are used in meat inspection programs. The use of ELISA for monitoring animals for infection in various porcine and equine pre- and post-slaughter programs, including farm or herd certification programs is also discussed. A brief review of the effectiveness of meat processing methods, such as freezing, cooking and preserving is provided. The importance of proper quality assurance and its application in all aspects of a Trichinella diagnostic system is emphasized. It includes the use of international quality standards, test validation and standardization, critical control points, laboratory accreditation, certification of analysts and proficiency testing. Also described, are the roles and locations of international and regional reference laboratories for trichinellosis where expert advice and support on research and diagnostics are available.

  12. [Stress-ECG is adequate to detect myocardial ischemia: when are additional diagnostic tests needed?].

    PubMed

    Baer, F M

    2007-09-01

    The stress-ECG is the most often adopted and most cost effective initial diagnostic test for the assessment of myocardial ischemia in patients with suspected coronary artery disease (CAD). Prerequisites for the diagnostic usefullness of stress-ECG are a clearly interpretable ST-segment, ability to reach the predicted work load, an intermediate pretest probability for CAD ranging between 10% and 90% and the absence of any contraindications for dynamic exercise. Because of the limited diagnostic sensitivity of about 70%, and a high percentage of patients, who are unable to exercise, a negative stress ECG can definitely not exclude hemodynamically significant CAD. Therefore, stress imaging techniques like myocardial scintigraphy, stress-echocardiography and stress magnetic resonance imaging play a major role in the stepwise diagnostic work-up of patients with suspected CAD. These stress imaging techniques are basically interchangeable since no method is definitely superior to one of the others. However, each method has its specific pros and cons and inherent contraindications. Therefore the choice of the stress imaging method and the form of stress applied should be based on the individual patients characteristics to gain optimal image quality and diagnostic accuracy. Moreover, the decision for one method should take the local availability and institutional expertise of diagnostic centers into account. Although partly substituted by stress imaging techniques the stress-ECG still remains the workhorse for a stepwise diagnostic work-up of patients with suspected CAD.

  13. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies

    PubMed Central

    Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491

  14. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.

    PubMed

    Erdoğan, Semra; Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.

  15. [Staged oncological screening with TG test].

    PubMed

    Bakhlaev, I E; Ageenko, A I; Rolik, I S

    2006-01-01

    The authors present their analysis of screening methods used for early diagnostics of cancer of various localization and for detection of high-risk individuals. They offer a program of step-by-step screening that makes it possible to cover more population with prophylactic examination and to reduce the need for special examination methods. TG-test is a universal and the most informative blastomatous process indicator at any stage, including the preclinical one. The practical screening results double the revealing rate of oncopathology and allow for three-fold reduction in the diagnostic costs compared with standard methods of cancer diagnostics. The medical efficiency of the oncological screening is high; in one third of the examined patients a tumor is diagnosed at the preclinical stage.

  16. Automatic brain caudate nuclei segmentation and classification in diagnostic of Attention-Deficit/Hyperactivity Disorder.

    PubMed

    Igual, Laura; Soliva, Joan Carles; Escalera, Sergio; Gimeno, Roger; Vilarroya, Oscar; Radeva, Petia

    2012-12-01

    We present a fully automatic diagnostic imaging test for Attention-Deficit/Hyperactivity Disorder diagnosis assistance based on previously found evidences of caudate nucleus volumetric abnormalities. The proposed method consists of different steps: a new automatic method for external and internal segmentation of caudate based on Machine Learning methodologies; the definition of a set of new volume relation features, 3D Dissociated Dipoles, used for caudate representation and classification. We separately validate the contributions using real data from a pediatric population and show precise internal caudate segmentation and discrimination power of the diagnostic test, showing significant performance improvements in comparison to other state-of-the-art methods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Veronica J.; ANU)

    An early diagnosis of malignancies correlates directly with a better prognosis. Yet for many malignancies there are no readily available, noninvasive, cost-effective diagnostic tests with patients often presenting too late for effective treatment. This article describes for the first time the use of fiber diffraction patterns of skin or fingernails, using X-ray sources, as a biometric diagnostic method for detecting neoplastic disorders including but not limited to melanoma, breast, colon and prostate cancers. With suitable further development, an early low-cost, totally noninvasive yet reliable diagnostic test could be conducted on a regular basis in local radiology facilities, as a confirmatorymore » test for other diagnostic procedures or as a mass screening test using suitable small angle X-ray beam-lines at synchrotrons.« less

  18. Meta-analysis of diagnostic test data: a bivariate Bayesian modeling approach.

    PubMed

    Verde, Pablo E

    2010-12-30

    In the last decades, the amount of published results on clinical diagnostic tests has expanded very rapidly. The counterpart to this development has been the formal evaluation and synthesis of diagnostic results. However, published results present substantial heterogeneity and they can be regarded as so far removed from the classical domain of meta-analysis, that they can provide a rather severe test of classical statistical methods. Recently, bivariate random effects meta-analytic methods, which model the pairs of sensitivities and specificities, have been presented from the classical point of view. In this work a bivariate Bayesian modeling approach is presented. This approach substantially extends the scope of classical bivariate methods by allowing the structural distribution of the random effects to depend on multiple sources of variability. Meta-analysis is summarized by the predictive posterior distributions for sensitivity and specificity. This new approach allows, also, to perform substantial model checking, model diagnostic and model selection. Statistical computations are implemented in the public domain statistical software (WinBUGS and R) and illustrated with real data examples. Copyright © 2010 John Wiley & Sons, Ltd.

  19. Tips and tricks in the dermoscopy of pigmented lesions

    PubMed Central

    2012-01-01

    Dermoscopy is a useful, widely used tool for examining pigmented lesions, especially helpful in cases of an uncertain nature. Nevertheless, doctors may experience diagnostic difficulties while using this method. An example of this may be found in the examination of subcorneal hematoma, dark nevi with black lamella or lesions of acral volar skin. In such cases, a few diagnostic tricks have proven to be helpful in achieving diagnostic accuracy. This paper reviews various methods of performing dermoscopy, suggesting a number of simple, yet helpful tests. These include the adhesive tape test, the skin scraping test and the ink furrow test. The adhesive tape test is helpful in differentiating between dark melanocytic nevi and melanoma. Hematoma may be more easily differentiated with the use of the so-called skin scraping test. The confirmation of benign and melanocytic lesions of acral volar skin, on the other hand, is more accurate when using the ink furrow test. These methods have been discussed here based upon a series of literature reviews, the authors’ own experience and, also, iconography. The present article describes novel methods used in dermoscopy, helping to bring about a faster, more accurate diagnostics of those lesions which have proven to be more difficult to recognize. Helpful tricks, such as have been known to professional literature, as well as the authors’ own experience (for instance, applying urea cream to hyperkeratotic lesions or using photographs of skin lesions taken with the aid of a mobile phone camera – all prior to surgery) will surely be considered beneficial to the practitioner, be it dermatologist or any other physician. PMID:22916721

  20. Diagnostic methods of TSH in thyroid screening tests.

    PubMed

    Matyjaszek-Matuszek, Beata; Pyzik, Aleksandra; Nowakowski, Andrzej; Jarosz, Mirosław J

    2013-01-01

    Reliable and quick thyreologic diagnostics, as well as verification of the effectiveness of the therapy undertaken, is of great importance for the state of health of society. The measurement of plasma TSH is the commonly accepted and most sensitive screening test for primary thyroid disorders, which are the most frequent diseases related to the endocrine glands. At present, the available methods for the determination of TSH are characterized by high sensitivity ≤0.01 µIU/ml and lack of cross-reactivity. However, many drugs and substances, as well as pathological conditions, may affect the TSH level. evaluation of contemporary laboratory methods for the determination of TSH and the principles of interpretation of screening tests. In many countries, the TSH test is the only test performed in the diagnostics of thyroid function; nevertheless, it seems that for genuine and objective assessment of thyroid status the TSH level, together with FT4 level, should be absolutely determined, which allows the differentiation and assessment of the intensity of thyroid function disorders and foresee its consequences. The interpretation of TSH results in screening tests is different in such population groups as: children aged under 14, pregnant women, the elderly, and patients with non-thyroidal illnesses. From among currently used laboratory methods for determination of TSH levels, third generation non-isotopic methods are most frequently recommended, especially the method of immunochemiluminescence.

  1. Constructing and Validating a Q-Matrix for Cognitive Diagnostic Analyses of a Reading Test

    ERIC Educational Resources Information Center

    Li, Hongli; Suen, Hoi K.

    2013-01-01

    Cognitive diagnostic analyses have been advocated as methods that allow an assessment to function as a formative assessment to inform instruction. To use this approach, it is necessary to first identify the skills required for each item in the test, known as a Q-matrix. However, because the construct being tested and the underlying cognitive…

  2. Promoting the hydrostatic conceptual change test (HCCT) with four-tier diagnostic test item

    NASA Astrophysics Data System (ADS)

    Purwanto, M. G.; Nurliani, R.; Kaniawati, I.; Samsudin, A.

    2018-05-01

    Hydrostatic Conceptual Change Test (HCCT) is a diagnostic test instrument to identify students’ conception on Hydrostatic field. It is very important to support the learning process in the classroom. Based on that point of view, the researcher decided to develop HCCT instrument test into four-tier test diagnostic items. The resolve of this research is planned as the first step of four-tier test-formatted HCCT development as one of investigative test instrument on Hydrostatic. The research method used the 4D model which has four comprehensive steps: 1) defining, 2) designing, 3) developing and 4) disseminating. The instrument developed has been tried to 30 students in one of senior high schools. The data showed that four-tier- test-formatted HCCT is able to identify student’s conception level of Hydrostatic. In conclusion, the development of four-tier test-formatted HCCT is one of potential diagnostic test instrument that able to classify the category of students who misconception, no understanding, understanding, partial understanding and no codeable about concept of Hydrostatic.

  3. Iridology: A systematic review.

    PubMed

    Ernst, E

    1999-02-01

    Iridologists claim to be able to diagnose medical conditions through abnormalities of pigmentation in the iris. This technique is popular in many countries. Therefore it is relevant to ask whether it is valid. To systematically review all interpretable tests of the validity of iridology as a diagnostic tool. DATA SOURCE AND EXTRACTION: Three independent literature searches were performed to identify all blinded tests. Data were extracted in a predefined, standardized fashion. Four case control studies were found. The majority of these investigations suggests that iridology is not a valid diagnostic method. The validity of iridology as a diagnostic tool is not supported by scientific evaluations. Patients and therapists should be discouraged from using this method.

  4. Predictors of Inappropriate Use of Diagnostic Tests and Management of Bronchiolitis

    PubMed Central

    Sarmiento, Lorena; Rojas-Soto, Gladys E.

    2017-01-01

    Background The aim of the present study was to determine predictors of inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. Methods In an analytical cross-sectional study, we determined independent predictors of the inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. We defined a composite outcome score as the main outcome variable. Results Of the 303 included patients, 216 (71.3%) experienced an inappropriate use of diagnostic tests and treatment of bronchiolitis. After controlling for potential confounders, it was found that atopic dermatitis (OR 5.30; CI 95% 1.14–24.79; p = 0.034), length of hospital stay (OR 1.48; CI 95% 1.08–2.03; p = 0.015), and the number of siblings (OR 1.92; CI 95% 1.13–3.26; p = 0.015) were independent predictors of an inappropriate use of diagnostic tests and treatment of the disease. Conclusions Inappropriate use of diagnostic tests and treatment of bronchiolitis was a highly prevalent outcome in our population of study. Participants with atopic dermatitis, a longer hospital stay, and a greater number of siblings were at increased risk for inappropriate use of diagnostic tests and management of the disease. PMID:28758127

  5. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology

    PubMed Central

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B.; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-01-01

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is <30%. Many different test-methods have been proposed to increase diagnostic accuracy in such lesions, including Galectin-3-ICC (GAL-3-ICC), BRAF mutation analysis (BRAF), Gene Expression Classifier (GEC) alone and GEC+BRAF, mutation/fusion (M/F) panel, alone, M/F panel+miRNA GEC, and M/F panel by next generation sequencing (NGS), FDG-PET/CT, MIBI-Scan and TSHR mRNA blood assay. We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings. In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions. PMID:28472764

  6. Diagnostic triage and the role of natriuretic peptide testing and echocardiography for suspected heart failure: an appropriateness ratings evaluation by UK GPs

    PubMed Central

    Campbell, Stephen M; Fuat, Ahmet; Summerton, Nick; Lancaster, Neil; Hobbs, FD Richard

    2011-01-01

    Background Some UK GPs are acquiring access to natriuretic peptide (NP) testing or echocardiography as diagnostic tests for heart failure. This study developed appropriateness ratings for the diagnostic application of these tests in routine general practice. Aim To develop appropriateness ratings for the diagnostic application of NP testing or echocardiography for heart failure in general practice. Design and setting An appropriateness ratings evaluation in UK general practice. Method Four presenting symptoms (cough, bilateral ankle swelling, dyspnoea, fatigue), three levels of risk of cardiovascular disease (low, intermediate, high), and dichotomous categorisations of cardiovascular/chest examination and electrocardiogram result, were used to create 540 appropriateness scenarios for patients in whom NP testing or echocardiography might be considered. These were rated by a 10-person expert panel, consisting of GPs and GPs with specialist interests in cardiology, in a two-round RAND Appropriateness Method. Results Onward referral for NP testing or echocardiography was rated as an appropriate next step in 217 (40.2%) of the 540 scenarios; in 194 (35.9%) it was rated inappropriate. The ratings also show where NP testing or echocardiography were ranked as equivalent next steps and when one test was seen as the more appropriate than the other. Conclusion NP testing should be the routine test for suspected heart failure where referral for diagnostic testing is considered appropriate. An abnormal electrocardiogram status makes referral to echocardiography an accompanying, or more appropriate, next step alongside NP testing, especially in the presence of dyspnoea. Abnormal NP testing should subsequently be followed up with referral for echocardiography. PMID:21722451

  7. On determining the most appropriate test cut-off value: the case of tests with continuous results

    PubMed Central

    Habibzadeh, Parham; Yadollahie, Mahboobeh

    2016-01-01

    There are several criteria for determination of the most appropriate cut-off value in a diagnostic test with continuous results. Mostly based on receiver operating characteristic (ROC) analysis, there are various methods to determine the test cut-off value. The most common criteria are the point on ROC curve where the sensitivity and specificity of the test are equal; the point on the curve with minimum distance from the left-upper corner of the unit square; and the point where the Youden’s index is maximum. There are also methods mainly based on Bayesian decision analysis. Herein, we show that a proposed method that maximizes the weighted number needed to misdiagnose, an index of diagnostic test effectiveness we previously proposed, is the most appropriate technique compared to the aforementioned ones. For determination of the cut-off value, we need to know the pretest probability of the disease of interest as well as the costs incurred by misdiagnosis. This means that even for a certain diagnostic test, the cut-off value is not universal and should be determined for each region and for each disease condition. PMID:27812299

  8. [Comparative diagnostic value of Helicobacter pylori infection testing methods].

    PubMed

    Girdalidze, A M; Elisabedashvili, G V; Sharvadze, L G; Dzhorbenadze, T A

    2013-12-01

    In 213 patients with gastric and duodenal pathology, including received surgery, comparative estimation of results of Helicobacter pylori (Hp) infection testing with invasive and noninvasive methods, were performed. Material for invasive endoscopic biopsy test (EBT), including rapid urease test (RUT) for rapid Hp identification by determination of urease activity, smear cytology and histology was extracted on endoscopy or intraoperationally. RUT was carried out with the help of URE-HP test kit. Serological test for Hp antibodies IgG and IgA class was performed by IFA using kit ELISA. 13С urea breath test (UBT) was made by determination of 13/12CO2 in breath samples on infrared spectroscope. Based on 5 different methods of Hp infection testing Hp positivity in 172 (80,8%) and Hp negativity in 41 (19,2%) from 213 examined patients was revealed. 13С-UBT revealed the highest diagnostic value (accuracy-97,5%, sensibility-97,0%, specificity-100%) in Hp infection diagnostics. In treatment efficiency control this parameters of 13С-UBT are also much high (96,7%, 90,0% and 100% respectively). In spite of high sensitivity of serological test (100%), it had comparative low specificity (71,0%) with high probability of false positive results in treated patients (antibodies titer to Hp after eradication retains for a long time). Thought, this test may be successfully used only in primary patients and in epidemiological studies. Among three methods of EBT, Hp infection detection with RUT revealed the best results (accuracy-94,8%, sensibility-95,0%, specificity-100%). Correlation of RUT and UBT results and much higher diagnostic value of UBT, necessitate RUT with histological study of stomach body mucosa to perform in patients over 45 year, with prolonged anamnesis and dangerous symptoms of disease. In Hp positive patients correlation of index DOB‰ of breath test with results of RUT was revealed. This can serve the index DOB‰ of 13С-UBT as a marker of Hp infection rate. The (accuracy, sensibility and specificity of breath test with local made 13С-urea (98,7%, 98,5% and 100% respectively) are the same as those for BT with standard 13С-urea (96,7%, 96,2% and 100% respectively). Above mentioned, 13С-UBT advantages (noninvasiveness, simplicity, rapidity, safety) and high diagnostic value exceeding same of other applied tests, give us opportunity to offer 13С-UBT as screening method of Hp infection diagnosis and a method of choise in control of Hp infection treatment efficiency.

  9. EVALUATION AND IMPORTANCE OF SELECTED MICROBIOLOGICAL METHODS IN THE DIAGNOSIS OF HUMAN BRUCELLOSIS

    PubMed Central

    Šiširak, Maida; Hukić, Mirsada

    2009-01-01

    Brucellosis is an important public health problem in Bosnia and Herzegovina. The diagnosis of bru-cellosis in the country without any experiences with this kind of infection may be very difficult. The aim of this study was to evaluate diagnostic methods: Rose Bengal test, blood cultures and ELISA IgM and IgG in the patients with brucellosis. The study included 91 brucellosis patients in the period 2004 to 2007. All the patients were treated at the Clinic for Infectious Diseases, University of Sarajevo Clinics Centre. Blood cultures were positive in 28/91 (30, 8%) patients. This method often needs a long period of incubation and specimens need to be obtained early. These limitations make serology the most useful tool for the laboratory diagnosis of Brucella infection. Rose Bengal is a rapid plate agglutination test, very sensitive irrespective of the stage of the disease. In our study, Rose Bengal test was positive in all patients 91/91 (100, 0%). Brucella IgM antibodies with ELISA were positive in 59/91 (64, 8%). Brucella IgG antibodies with ELISA were positive in 51/91 (56%). In order to determine the diagnostic value of the different tests, we compared the sensitivity among test-methods: Rose Bengal test-100.0%, blood culture-30.8%, ELISA IgM-64.8% and ELISA IgG-56.1%. Sensitivity of test methods was different in the different stages of illness. It is necessary to use combination of different tests such are blood culture, Rose Bengal test and ELISA in order to ensure the diagnosis. Rose Bengal test is excellent for the screening. Blood culture is a method of choice for the diagnosis acute infection. ELISA is a very good method for the diagnostic chronic disease and relapse. PMID:19754473

  10. Repeated significance tests of linear combinations of sensitivity and specificity of a diagnostic biomarker

    PubMed Central

    Wu, Mixia; Shu, Yu; Li, Zhaohai; Liu, Aiyi

    2016-01-01

    A sequential design is proposed to test whether the accuracy of a binary diagnostic biomarker meets the minimal level of acceptance. The accuracy of a binary diagnostic biomarker is a linear combination of the marker’s sensitivity and specificity. The objective of the sequential method is to minimize the maximum expected sample size under the null hypothesis that the marker’s accuracy is below the minimal level of acceptance. The exact results of two-stage designs based on Youden’s index and efficiency indicate that the maximum expected sample sizes are smaller than the sample sizes of the fixed designs. Exact methods are also developed for estimation, confidence interval and p-value concerning the proposed accuracy index upon termination of the sequential testing. PMID:26947768

  11. Discussion of the quality control and performance testing of ultrasound diagnostic equipment

    NASA Astrophysics Data System (ADS)

    Jiang, Junjie

    2018-03-01

    In recent years, with the rapid development of ultrasonography, the application and popularization of new technology used in ultrasound equipment, the level of providing diagnostic information for doctors enhances unceasingly, which has become the indispensable diagnostic tool for medical institutions. The performance of equipment is directly related to the doctor’s diagnosis and the patient’s health, therefore, it is very important to choose a good method for quality control and performance testing.

  12. Dual-Objective Item Selection Criteria in Cognitive Diagnostic Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Kang, Hyeon-Ah; Zhang, Susu; Chang, Hua-Hua

    2017-01-01

    The development of cognitive diagnostic-computerized adaptive testing (CD-CAT) has provided a new perspective for gaining information about examinees' mastery on a set of cognitive attributes. This study proposes a new item selection method within the framework of dual-objective CD-CAT that simultaneously addresses examinees' attribute mastery…

  13. Development and Preparation of Lead-Containing Paint Films and Diagnostic Test Materials

    EPA Science Inventory

    Lead in paint continues to be a threat to children’s health in cities across the United States, which means there is an ongoing need for testing and analysis of paint. This ongoing analytical effort and especially development of new methods continue to drive the need for diagnost...

  14. Detection of scabies: A systematic review of diagnostic methods

    PubMed Central

    Leung, Victor; Miller, Mark

    2011-01-01

    BACKGROUND: Accurate diagnosis of scabies infection is important for patient treatment and for public health control of scabies epidemics. OBJECTIVE: To systematically review the accuracy and precision of history, physical examination and tests for diagnosing scabies. METHODS: Using a structured search strategy, Medline and Embase databases were searched for English and French language articles that included a diagnosis of scabies. Studies comparing history, physical examination and/or any diagnostic tests with the reference standard of microscopic visualization of mites, eggs or fecal elements obtained from skin scrapings or biopsies were included for analysis. Data were extracted using standard criteria. RESULTS: History and examination of pruritic dermatoses failed to accurately diagnose scabies infection. Dermatoscopy by a trained practitioner has a positive likelihood ratio of 6.5 (95% CI 4.1 to 10.3) and a negative likelihood ratio of 0.1 (95% CI 0.06 to 0.2) for diagnosing scabies. The accuracy of other diagnostic tests could not be calculated from the data in the literature. CONCLUSIONS: In the face of such diagnostic inaccuracy, clinical judgment is still practical in diagnosing scabies. Two tests are used – the burrow ink test and handheld dermatoscopy. The burrow ink test is a simple, rapid, noninvasive test that can be used to screen a large number of patients. Handheld dermatoscopy is an accurate test, but requires special equipment and trained practitioners. Given the morbidity and costs of scabies infection, and that studies to date lack adequate internal and external validity, research to identify or develop accurate diagnostic tests for scabies infection is needed and justifiable. PMID:23205026

  15. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments.

    PubMed

    Shinkins, Bethany; Yang, Yaling; Abel, Lucy; Fanshawe, Thomas R

    2017-04-14

    Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1) what evidence aside from test accuracy was searched for and synthesised, 2) which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3) how/whether threshold effects were explored, 4) how the potential dependency between multiple tests in a pathway was accounted for, and 5) for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings. The uptake of appropriate meta-analysis methods for synthesising evidence on diagnostic test accuracy in UK NIHR HTAs has improved in recent years. Future research should focus on other evidence requirements for cost-effectiveness assessment, threshold effects for quantitative tests and the impact of multiple diagnostic tests.

  16. Diagnostic grand rounds: a new teaching concept to train diagnostic reasoning.

    PubMed

    Stieger, Stefan; Praschinger, Andrea; Kletter, Kurt; Kainberger, Franz

    2011-06-01

    Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  17. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    PubMed Central

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  18. Clinical evaluation and validation of laboratory methods for the diagnosis of Bordetella pertussis infection: Culture, polymerase chain reaction (PCR) and anti-pertussis toxin IgG serology (IgG-PT).

    PubMed

    Lee, Adria D; Cassiday, Pamela K; Pawloski, Lucia C; Tatti, Kathleen M; Martin, Monte D; Briere, Elizabeth C; Tondella, M Lucia; Martin, Stacey W

    2018-01-01

    The appropriate use of clinically accurate diagnostic tests is essential for the detection of pertussis, a poorly controlled vaccine-preventable disease. The purpose of this study was to estimate the sensitivity and specificity of different diagnostic criteria including culture, multi-target polymerase chain reaction (PCR), anti-pertussis toxin IgG (IgG-PT) serology, and the use of a clinical case definition. An additional objective was to describe the optimal timing of specimen collection for the various tests. Clinical specimens were collected from patients with cough illness at seven locations across the United States between 2007 and 2011. Nasopharyngeal and blood specimens were collected from each patient during the enrollment visit. Patients who had been coughing for ≤ 2 weeks were asked to return in 2-4 weeks for collection of a second, convalescent blood specimen. Sensitivity and specificity of each diagnostic test were estimated using three methods-pertussis culture as the "gold standard," composite reference standard analysis (CRS), and latent class analysis (LCA). Overall, 868 patients were enrolled and 13.6% were B. pertussis positive by at least one diagnostic test. In a sample of 545 participants with non-missing data on all four diagnostic criteria, culture was 64.0% sensitive, PCR was 90.6% sensitive, and both were 100% specific by LCA. CRS and LCA methods increased the sensitivity estimates for convalescent serology and the clinical case definition over the culture-based estimates. Culture and PCR were most sensitive when performed during the first two weeks of cough; serology was optimally sensitive after the second week of cough. Timing of specimen collection in relation to onset of illness should be considered when ordering diagnostic tests for pertussis. Consideration should be given to including IgG-PT serology as a confirmatory test in the Council of State and Territorial Epidemiologists (CSTE) case definition for pertussis.

  19. Cost analysis of breast cancer diagnostic assessment programs.

    PubMed

    Honein-AbouHaidar, G N; Hoch, J S; Dobrow, M J; Stuart-McEwan, T; McCready, D R; Gagliardi, A R

    2017-10-01

    Diagnostic assessment programs (daps) appear to improve the diagnosis of cancer, but evidence of their cost-effectiveness is lacking. Given that no earlier study used secondary financial data to estimate the cost of diagnostic tests in the province of Ontario, we explored how to use secondary financial data to retrieve the cost of key diagnostic test services in daps, and we tested the reliability of that cost-retrieving method with hospital-reported costs in preparation for future cost-effectiveness studies. We powered our sample at an alpha of 0.05, a power of 80%, and a margin of error of ±5%, and randomly selected a sample of eligible patients referred to a dap for suspected breast cancer during 1 January-31 December 2012. Confirmatory diagnostic tests received by each patient were identified in medical records. Canadian Classification of Health Intervention procedure codes were used to search the secondary financial data Web portal at the Ontario Case Costing Initiative for an estimate of the direct, indirect, and total costs of each test. The hospital-reported cost of each test received was obtained from the host-hospital's finance department. Descriptive statistics were used to calculate the cost of individual or group confirmatory diagnostic tests, and the Wilcoxon signed-rank test or the paired t-test was used to compare the Ontario Case Costing Initiative and hospital-reported costs. For the 191 identified patients with suspected breast cancer, the estimated total cost of $72,195.50 was not significantly different from the hospital-reported total cost of $72,035.52 ( p = 0.24). Costs differed significantly when multiple tests to confirm the diagnosis were completed during one patient visit and when confirmatory tests reported in hospital data and in medical records were discrepant. The additional estimated cost for non-salaried physicians delivering diagnostic services was $28,387.50. It was feasible to use secondary financial data to retrieve the cost of key diagnostic tests in a breast cancer dap and to compare the reliability of the costs obtained by that estimation method with hospital-reported costs. We identified the strengths and challenges of each approach. Lessons learned from this study have to be taken into consideration in future cost-effectiveness studies.

  20. Development of monitoring and diagnostic methods for robots used in remediation of waste sites. 1997 annual progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tecza, J.

    1998-06-01

    'Safe and efficient clean up of hazardous and radioactive waste sites throughout the DOE complex will require extensive use of robots. This research effort focuses on developing Monitoring and Diagnostic (M and D) methods for robots that will provide early detection, isolation, and tracking of impending faults before they result in serious failure. The utility and effectiveness of applying M and D methods to hydraulic robots has never been proven. The present research program is utilizing seeded faults in a laboratory test rig that is representative of an existing hydraulically-powered remediation robot. This report summarizes activity conducted in the firstmore » 9 months of the project. The research team has analyzed the Rosie Mobile Worksystem as a representative hydraulic robot, developed a test rig for implanted fault testing, developed a test plan and agenda, and established methods for acquiring and analyzing the test data.'« less

  1. Turfgrass diagnostics and new, advanced technologies

    USDA-ARS?s Scientific Manuscript database

    Strategies for sustainable, integrated disease management start with reliable pathogen identification. Conventional identification methods such as disease symptomology, host association, morphology and biochemical tests are still key diagnostic indicators for many phytopathogens; however, nucleic ac...

  2. A fault injection experiment using the AIRLAB Diagnostic Emulation Facility

    NASA Technical Reports Server (NTRS)

    Baker, Robert; Mangum, Scott; Scheper, Charlotte

    1988-01-01

    The preparation for, conduct of, and results of a simulation based fault injection experiment conducted using the AIRLAB Diagnostic Emulation facilities is described. An objective of this experiment was to determine the effectiveness of the diagnostic self-test sequences used to uncover latent faults in a logic network providing the key fault tolerance features for a flight control computer. Another objective was to develop methods, tools, and techniques for conducting the experiment. More than 1600 faults were injected into a logic gate level model of the Data Communicator/Interstage (C/I). For each fault injected, diagnostic self-test sequences consisting of over 300 test vectors were supplied to the C/I model as inputs. For each test vector within a test sequence, the outputs from the C/I model were compared to the outputs of a fault free C/I. If the outputs differed, the fault was considered detectable for the given test vector. These results were then analyzed to determine the effectiveness of some test sequences. The results established coverage of selt-test diagnostics, identified areas in the C/I logic where the tests did not locate faults, and suggest fault latency reduction opportunities.

  3. Development of a framework for international certification by OIE of diagnostic tests validated as fit for purpose.

    PubMed

    Wright, P; Edwards, S; Diallo, A; Jacobson, R

    2006-01-01

    Historically, the OIE has focused on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants' meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.

  4. Development of a framework for international certification by the OIE of diagnostic tests validated as fit for purpose.

    PubMed

    Wright, P; Edwards, S; Diallo, A; Jacobson, R

    2007-01-01

    Historically, the OIE has focussed on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.

  5. Detection of Mycoplasma hyopneumoniae by polymerase chain reaction in swine presenting respiratory problems

    PubMed Central

    Yamaguti, M.; Muller, E.E.; Piffer, A.I.; Kich, J.D.; Klein, C.S.; Kuchiishi, S.S.

    2008-01-01

    Since Mycoplasma hyopneumoniae isolation in appropriate media is a difficult task and impractical for daily routine diagnostics, Nested-PCR (N-PCR) techniques are currently used to improve the direct diagnostic sensitivity of Swine Enzootic Pneumonia. In a first experiment, this paper describes a N-PCR technique optimization based on three variables: different sampling sites, sample transport media, and DNA extraction methods, using eight pigs. Based on the optimization results, a second experiment was conducted for testing validity using 40 animals. In conclusion, the obtained results of the N-PCR optimization and validation allow us to recommend this test as a routine monitoring diagnostic method for Mycoplasma hyopneumoniae infection in swine herds. PMID:24031248

  6. Meta-analysis of diagnostic accuracy studies in mental health

    PubMed Central

    Takwoingi, Yemisi; Riley, Richard D; Deeks, Jonathan J

    2015-01-01

    Objectives To explain methods for data synthesis of evidence from diagnostic test accuracy (DTA) studies, and to illustrate different types of analyses that may be performed in a DTA systematic review. Methods We described properties of meta-analytic methods for quantitative synthesis of evidence. We used a DTA review comparing the accuracy of three screening questionnaires for bipolar disorder to illustrate application of the methods for each type of analysis. Results The discriminatory ability of a test is commonly expressed in terms of sensitivity (proportion of those with the condition who test positive) and specificity (proportion of those without the condition who test negative). There is a trade-off between sensitivity and specificity, as an increasing threshold for defining test positivity will decrease sensitivity and increase specificity. Methods recommended for meta-analysis of DTA studies --such as the bivariate or hierarchical summary receiver operating characteristic (HSROC) model --jointly summarise sensitivity and specificity while taking into account this threshold effect, as well as allowing for between study differences in test performance beyond what would be expected by chance. The bivariate model focuses on estimation of a summary sensitivity and specificity at a common threshold while the HSROC model focuses on the estimation of a summary curve from studies that have used different thresholds. Conclusions Meta-analyses of diagnostic accuracy studies can provide answers to important clinical questions. We hope this article will provide clinicians with sufficient understanding of the terminology and methods to aid interpretation of systematic reviews and facilitate better patient care. PMID:26446042

  7. Impact of gene patents on diagnostic testing: a new patent landscaping method applied to spinocerebellar ataxia

    PubMed Central

    Berthels, Nele; Matthijs, Gert; Van Overwalle, Geertrui

    2011-01-01

    Recent reports in Europe and the United States raise concern about the potential negative impact of gene patents on the freedom to operate of diagnosticians and on the access of patients to genetic diagnostic services. Patents, historically seen as legal instruments to trigger innovation, could cause undesired side effects in the public health domain. Clear empirical evidence on the alleged hindering effect of gene patents is still scarce. We therefore developed a patent categorization method to determine which gene patents could indeed be problematic. The method is applied to patents relevant for genetic testing of spinocerebellar ataxia (SCA). The SCA test is probably the most widely used DNA test in (adult) neurology, as well as one of the most challenging due to the heterogeneity of the disease. Typically tested as a gene panel covering the five common SCA subtypes, we show that the patenting of SCA genes and testing methods and the associated licensing conditions could have far-reaching consequences on legitimate access to this gene panel. Moreover, with genetic testing being increasingly standardized, simply ignoring patents is unlikely to hold out indefinitely. This paper aims to differentiate among so-called ‘gene patents' by lifting out the truly problematic ones. In doing so, awareness is raised among all stakeholders in the genetic diagnostics field who are not necessarily familiar with the ins and outs of patenting and licensing. PMID:21811306

  8. Validation of Ten Noninvasive Diagnostic Models for Prediction of Liver Fibrosis in Patients with Chronic Hepatitis B

    PubMed Central

    Cheng, Jieyao; Hou, Jinlin; Ding, Huiguo; Chen, Guofeng; Xie, Qing; Wang, Yuming; Zeng, Minde; Ou, Xiaojuan; Ma, Hong; Jia, Jidong

    2015-01-01

    Background and Aims Noninvasive models have been developed for fibrosis assessment in patients with chronic hepatitis B. However, the sensitivity, specificity and diagnostic accuracy in evaluating liver fibrosis of these methods have not been validated and compared in the same group of patients. The aim of this study was to verify the diagnostic performance and reproducibility of ten reported noninvasive models in a large cohort of Asian CHB patients. Methods The diagnostic performance of ten noninvasive models (HALF index, FibroScan, S index, Zeng model, Youyi model, Hui model, APAG, APRI, FIB-4 and FibroTest) was assessed against the liver histology by ROC curve analysis in CHB patients. The reproducibility of the ten models were evaluated by recalculating the diagnostic values at the given cut-off values defined by the original studies. Results Six models (HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest) had AUROCs higher than 0.70 in predicting any fibrosis stage and 2 of them had best diagnostic performance with AUROCs to predict F≥2, F≥3 and F4 being 0.83, 0.89 and 0.89 for HALF index, 0.82, 0.87 and 0.87 for FibroScan, respectively. Four models (HALF index, FibroScan, Zeng model and Youyi model) showed good diagnostic values at given cut-offs. Conclusions HALF index, FibroScan, Zeng model, Youyi model, S index and FibroTest show a good diagnostic performance and all of them, except S index and FibroTest, have good reproducibility for evaluating liver fibrosis in CHB patients. Registration Number ChiCTR-DCS-07000039. PMID:26709706

  9. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    PubMed

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  10. Does the Alpha-defensin Immunoassay or the Lateral Flow Test Have Better Diagnostic Value for Periprosthetic Joint Infection? A Systematic Review.

    PubMed

    Eriksson, Hannah K; Nordström, Jakob; Gabrysch, Katja; Hailer, Nils P; Lazarinis, Stergios

    2018-05-01

    Measuring alpha-defensin concentrations in synovial fluid may help to diagnose periprosthetic joint infection (PJI). There are two commercially available methods for measuring alpha-defensin in synovial fluid: the enzyme-linked immunosorbent assay-based Synovasure® alpha-defensin immunoassay, which gives a numeric readout within 24 hours, and the Synovasure lateral flow test, which gives a binary readout within 20 minutes. There is no compilation of the existing literature to support the use of one of these two tests over the other. Does the immunoassay or the lateral flow test have better diagnostic value (sensitivity and specificity) in diagnosing PJI? We followed PRISMA guidelines and identified all studies on alpha-defensin concentration in synovial fluid as a PJI diagnostic marker, indexed to April 14, 2017, in PubMed, JSTOR, Google Scholar, and OVID databases. The search retrieved 1578 records. All prospective and retrospective studies on alpha-defensin as a PJI marker (PJI classified according to the criteria of the Musculoskeletal Infection Society) after THA or TKA were included in the analysis. All studies used only one of the two commercially available test methods, but none of them was comparative. After excluding studies with overlapping patient populations, four studies investigating the alpha-defensin immunoassay and three investigating the lateral flow test remained. Alpha-defensin immunoassay studies included 482 joints and lateral flow test studies included 119. The quality of the trials was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The heterogeneity among studies was evaluated by the I index, indicating that the heterogeneity of the included studies was low. Pooled sensitivity, specificity, positive and negative likelihood ratios, and receiver operating curves were calculated for each method and compared with each other. The alpha-defensin immunoassay had superior overall diagnostic value compared with the lateral flow test (area under the curve, 0.98 versus 0.75) with higher sensitivity (96% [90%-98%] versus 71% [55%-83%], p < 0.001), but no difference in specificity with the numbers available (96% [93%-97%] versus 90% [81%-95%], p = 0.060). Measurement of alpha-defensin in synovial fluid is a valuable complement to existing diagnostic criteria, and the immunoassay test detects PJI more accurately than the lateral flow test. The lateral flow test has lower sensitivity, making it difficult to rule out infection, but its relatively high specificity combined with the advantage of a quick response time can make it useful to rule in infection perioperatively. Level III, diagnostic study.

  11. [Visualisation methods for etheric formative forces].

    PubMed

    Burkhard, B; Kittel, R

    2009-09-01

    Rudolf Steiner, the founder of anthroposophy, suggested the development of visualisation methods for "etheric formative forces". The essential methods, their "spiritual scientific" basis and indications are described and their claims critically tested. The methods are not validated, the key criteria for diagnostic tests (reproducibility, sensitivity, specifity) are not given.

  12. Bayesian analysis of two diagnostic methods for paediatric ringworm infections in a teaching hospital.

    PubMed

    Rath, S; Panda, M; Sahu, M C; Padhy, R N

    2015-09-01

    Quantitatively, conventional methods of diagnosis of tinea capitis or paediatric ringworm, microscopic and culture tests were evaluated with Bayes rule. This analysis would help in quantifying the pervasive errors in each diagnostic method, particularly the microscopic method, as a long-term treatment would be involved to eradicate the infection by the use of a particular antifungal chemotherapy. Secondly, the analysis of clinical data would help in obtaining digitally the fallible standard of the microscopic test method, as the culture test method is taken as gold standard. Test results of 51 paediatric patients were of 4 categories: 21 samples were true positive (both tests positive), and 13 were true negative; the rest samples comprised both 14 false positive (microscopic test positivity with culture test negativity) and 3 false negative (microscopic test negativity with culture test positivity) samples. The prevalence of tinea infection was 47.01% in the population of 51 children. The microscopic test of a sample was efficient by 87.5%, in arriving at a positive result on diagnosis, when its culture test was positive; and, this test was efficient by 76.4%, in arriving at a negative result, when its culture test was negative. But, the post-test probability value of a sample with both microscopic and culture tests would be correct in distinguishing a sample from a sick or a healthy child with a chance of 71.5%. However, since the sensitivity of the analysis is 87.5%, the microscopic test positivity would be easier to detect in the presence of infection. In conclusion, it could be stated that Trychophyton rubrum was the most prevalent species; sensitivity and specificity of treating the infection, by antifungal therapy before ascertaining by the culture method remain as 0.8751 and 0.7642, respectively. A correct/coveted diagnostic method of fungal infection would be could be achieved by modern molecular methods (matrix-assisted laser desorption ionisation-time of flight mass spectrometry or fluorescence in situ hybridization or enzyme-linked immunosorbent assay [ELISA] or restriction fragment length polymorphism or DNA/RNA probes of known fungal taxa) in advanced laboratories. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  13. NGS of Virus-Derived Small RNAs as a Diagnostic Method Used to Determine Viromes of Hungarian Vineyards

    PubMed Central

    Czotter, Nikoletta; Molnar, Janos; Szabó, Emese; Demian, Emese; Kontra, Levente; Baksa, Ivett; Szittya, Gyorgy; Kocsis, Laszlo; Deak, Tamas; Bisztray, Gyorgy; Tusnady, Gabor E.; Burgyan, Jozsef; Varallyay, Eva

    2018-01-01

    As virus diseases cannot be controlled by traditional plant protection methods, the risk of their spread have to be minimized on vegetatively propagated plants, such as grapevine. Metagenomic approaches used for virus diagnostics offer a unique opportunity to reveal the presence of all viral pathogens in the investigated plant, which is why their application can reduce the risk of using infected material for a new plantation. Here we used a special branch, deep sequencing of virus-derived small RNAs, of this high-throughput method for virus diagnostics, and determined viromes of vineyards in Hungary. With NGS of virus-derived small RNAs we could detect not only the viruses tested routinely, but also new ones, which had never been described in Hungary before. Virus presence did not correlate with the age of the plantation, moreover phylogenetic analysis of the identified virus isolates suggests that infections are mostly caused by the use of infected propagating material. Our results, validated by other molecular methods, raised further questions to be answered before this method can be introduced as a routine, reliable test for grapevine virus diagnostics. PMID:25741336

  14. Current status and future perspectives on molecular and serological methods in diagnostic mycology.

    PubMed

    Lau, Anna; Chen, Sharon; Sleiman, Sue; Sorrell, Tania

    2009-11-01

    Invasive fungal infections are an important cause of infectious morbidity. Nonculture-based methods are increasingly used for rapid, accurate diagnosis to improve patient outcomes. New and existing DNA amplification platforms have high sensitivity and specificity for direct detection and identification of fungi in clinical specimens. Since laboratories are increasingly reliant on DNA sequencing for fungal identification, measures to improve sequence interpretation should support validation of reference isolates and quality control in public gene repositories. Novel technologies (e.g., isothermal and PNA FISH methods), platforms enabling high-throughput analyses (e.g., DNA microarrays and Luminex xMAP) and/or commercial PCR assays warrant further evaluation for routine diagnostic use. Notwithstanding the advantages of molecular tests, serological assays remain clinically useful for patient management. The serum Aspergillus galactomannan test has been incorporated into diagnostic algorithms of invasive aspergillosis. Both the galactomannan and the serum beta-D-glucan test have value for diagnosing infection and monitoring therapeutic response.

  15. Diagnostic Accuracy and Cost-Effectiveness of Alternative Methods for Detection of Soil-Transmitted Helminths in a Post-Treatment Setting in Western Kenya

    PubMed Central

    Kepha, Stella; Kihara, Jimmy H.; Njenga, Sammy M.; Pullan, Rachel L.; Brooker, Simon J.

    2014-01-01

    Objectives This study evaluates the diagnostic accuracy and cost-effectiveness of the Kato-Katz and Mini-FLOTAC methods for detection of soil-transmitted helminths (STH) in a post-treatment setting in western Kenya. A cost analysis also explores the cost implications of collecting samples during school surveys when compared to household surveys. Methods Stool samples were collected from children (n = 652) attending 18 schools in Bungoma County and diagnosed by the Kato-Katz and Mini-FLOTAC coprological methods. Sensitivity and additional diagnostic performance measures were analyzed using Bayesian latent class modeling. Financial and economic costs were calculated for all survey and diagnostic activities, and cost per child tested, cost per case detected and cost per STH infection correctly classified were estimated. A sensitivity analysis was conducted to assess the impact of various survey parameters on cost estimates. Results Both diagnostic methods exhibited comparable sensitivity for detection of any STH species over single and consecutive day sampling: 52.0% for single day Kato-Katz; 49.1% for single-day Mini-FLOTAC; 76.9% for consecutive day Kato-Katz; and 74.1% for consecutive day Mini-FLOTAC. Diagnostic performance did not differ significantly between methods for the different STH species. Use of Kato-Katz with school-based sampling was the lowest cost scenario for cost per child tested ($10.14) and cost per case correctly classified ($12.84). Cost per case detected was lowest for Kato-Katz used in community-based sampling ($128.24). Sensitivity analysis revealed the cost of case detection for any STH decreased non-linearly as prevalence rates increased and was influenced by the number of samples collected. Conclusions The Kato-Katz method was comparable in diagnostic sensitivity to the Mini-FLOTAC method, but afforded greater cost-effectiveness. Future work is required to evaluate the cost-effectiveness of STH surveillance in different settings. PMID:24810593

  16. External quality assessment of dengue and chikungunya diagnostics in the Asia Pacific region, 2015

    PubMed Central

    Soh, Li Ting; Squires, Raynal C; Tan, Li Kiang; Pok, Kwoon Yong; Yang, HuiTing; Liew, Christina; Shah, Aparna Singh; Aaskov, John; Abubakar, Sazaly; Hasabe, Futoshi; Ng, Lee Ching

    2016-01-01

    Objective To conduct an external quality assessment (EQA) of dengue and chikungunya diagnostics among national-level public health laboratories in the Asia Pacific region following the first round of EQA for dengue diagnostics in 2013. Methods Twenty-four national-level public health laboratories performed routine diagnostic assays on a proficiency testing panel consisting of two modules. Module A contained serum samples spiked with cultured dengue virus (DENV) or chikungunya virus (CHIKV) for the detection of nucleic acid and DENV non-structural protein 1 (NS1) antigen. Module B contained human serum samples for the detection of anti-DENV antibodies. Results Among 20 laboratories testing Module A, 17 (85%) correctly detected DENV RNA by reverse transcription polymerase chain reaction (RT–PCR), 18 (90%) correctly determined serotype and 19 (95%) correctly identified CHIKV by RT–PCR. Ten of 15 (66.7%) laboratories performing NS1 antigen assays obtained the correct results. In Module B, 18/23 (78.3%) and 20/20 (100%) of laboratories correctly detected anti-DENV IgM and IgG, respectively. Detection of acute/recent DENV infection by both molecular (RT–PCR) and serological methods (IgM) was available in 19/24 (79.2%) participating laboratories. Discussion Accurate laboratory testing is a critical component of dengue and chikungunya surveillance and control. This second round of EQA reveals good proficiency in molecular and serological diagnostics of these diseases in the Asia Pacific region. Further comprehensive diagnostic testing, including testing for Zika virus, should comprise future iterations of the EQA. PMID:27508088

  17. Receiver operating characteristic (ROC) curves: review of methods with applications in diagnostic medicine

    NASA Astrophysics Data System (ADS)

    Obuchowski, Nancy A.; Bullen, Jennifer A.

    2018-04-01

    Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.

  18. Diagnosis of aphasia in stroke populations: A systematic review of language tests

    PubMed Central

    2018-01-01

    Background and purpose Accurate aphasia diagnosis is important in stroke care. A wide range of language tests are available and include informal assessments, tests developed by healthcare institutions and commercially published tests available for purchase in pre-packaged kits. The psychometrics of these tests are often reported online or within the purchased test manuals, not the peer-reviewed literature, therefore the diagnostic capabilities of these measures have not been systematically evaluated. This review aimed to identify both commercial and non-commercial language tests and tests used in stroke care and to examine the diagnostic capabilities of all identified measures in diagnosing aphasia in stroke populations. Methods Language tests were identified through a systematic search of 161 publisher databases, professional and resource websites and language tests reported to be used in stroke care. Two independent reviewers evaluated test manuals or associated resources for cohort or cross-sectional studies reporting the tests’ diagnostic capabilities (sensitivity, specificity, likelihood ratios or diagnostic odds ratios) in differentiating aphasic and non-aphasic stroke populations. Results Fifty-six tests met the study eligibility criteria. Six “non-specialist” brief screening tests reported sensitivity and specificity information, however none of these measures reported to meet the specific diagnostic needs of speech pathologists. The 50 remaining measures either did not report validity data (n = 7); did not compare patient test performance with a comparison group (n = 17); included non-stroke participants within their samples (n = 23) or did not compare stroke patient performance against a language reference standard (n = 3). Diagnostic sensitivity analysis was completed for six speech pathology measures (WAB, PICA, CADL-2, ASHA-FACS, Adult FAVRES and EFA-4), however all studies compared aphasic performance with that of non-stroke healthy controls and were consequently excluded from the review. Conclusions No speech pathology test was found which reported diagnostic data for identifying aphasia in stroke populations. A diagnostically validated post-stroke aphasia test is needed. PMID:29566043

  19. Diagnosis of Caprine Arthritis Encephalitis Virus infection in dairy goats by ELISA, PCR and Viral Culture.

    PubMed

    Panneum, S; Rukkwamsuk, T

    2017-03-01

    For preventive and control strategies of Caprine Arthritis Encephalitis Virus (CAEV) infection in dairy goats, performance of the available diagnostic tests was described as one of the most important and necessary aspects. The study aimed at evaluating the diagnostic test performance, including PCR, ELISA and viral culture, for CAEV infection in dairy goats in Thailand. Blood samples of 29 dairy goats from five low- to medium-prevalence herds and one very low-prevalence herd were collected for PCR and ELISA methods. The performance of these two diagnostic methods was evaluated by comparing with cytopathic effects (CPE) in the co-cultivation of CAEV and primary synovial cells. Results indicated that sensitivity, specificity were, respectively, 69.6%, 100%, for PCR; and 95.7%, 83.3% for ELISA. The PCR assay tended to have lower sensitivity and higher specificity than ELISA. When multiple tests were applied, parallel testing provided sensitivity and specificity of 98.7% and 83.3%, while series testing showed sensitivity and specificity of 66.6% and 100% respectively. These results indicated that combination of ELISA and PCR provided some advantages and possibly offered optimal methods to detect CAEV-infected goats. Kappa value of the agreement between PCR and ELISA test was 0.34, indicating fair agreement. Regarding the possibility of antigenic variation between CAEV strains used in both PCR and ELISA assays, the actual circulating CAEV strain should be reviewed in order to develop and enhance the diagnostic tests using the CAE viral antigens derived from specific local strains of Thailand.

  20. A clinical utility study of exome sequencing versus conventional genetic testing in pediatric neurology

    PubMed Central

    Vissers, Lisenka E.L.M.; van Nimwegen, Kirsten J.M.; Schieving, Jolanda H.; Kamsteeg, Erik-Jan; Kleefstra, Tjitske; Yntema, Helger G.; Pfundt, Rolph; van der Wilt, Gert Jan; Krabbenborg, Lotte; Brunner, Han G.; van der Burg, Simone; Grutters, Janneke; Veltman, Joris A.; Willemsen, Michèl A.A.P.

    2017-01-01

    Purpose: Implementation of novel genetic diagnostic tests is generally driven by technological advances because they promise shorter turnaround times and/or higher diagnostic yields. Other aspects, including impact on clinical management or cost-effectiveness, are often not assessed in detail prior to implementation. Methods: We studied the clinical utility of whole-exome sequencing (WES) in complex pediatric neurology in terms of diagnostic yield and costs. We analyzed 150 patients (and their parents) presenting with complex neurological disorders of suspected genetic origin. In a parallel study, all patients received both the standard diagnostic workup (e.g., cerebral imaging, muscle biopsies or lumbar punctures, and sequential gene-by-gene–based testing) and WES simultaneously. Results: Our unique study design allowed direct comparison of diagnostic yield of both trajectories and provided insight into the economic implications of implementing WES in this diagnostic trajectory. We showed that WES identified significantly more conclusive diagnoses (29.3%) than the standard care pathway (7.3%) without incurring higher costs. Exploratory analysis of WES as a first-tier diagnostic test indicates that WES may even be cost-saving, depending on the extent of other tests being omitted. Conclusion: Our data support such a use of WES in pediatric neurology for disorders of presumed genetic origin. Genet Med advance online publication 23 March 2017 PMID:28333917

  1. Inference of Antibiotic Resistance and Virulence Among Diverse Group A Streptococcus Strains Using emm Sequencing and Multilocus Genotyping Methods

    DTIC Science & Technology

    2009-09-04

    apparent GAS-associated conditions were sampled by oropharyn- geal swab. Swabs were streaked on blood agar plates using Table 3. Isolate properties by...testing, samples were re-streaked on blood agar plates (5% sheep blood in TSA base) (Hardy Diagnostics, Santa Maria, CA), and incubated at 35–37uC with 5–10...sensitivity (A-disk method, Hardy Diagnostics) and positive GAS latex agglutination reaction (Hardy Diagnostics). Confirmed GAS isolates were then

  2. Performance of seven serological assays for diagnosing tularemia

    PubMed Central

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  3. Expanding Access to Malaria Diagnosis through Retail Shops in Western Kenya: What Do Shop Workers Think?

    PubMed

    Rusk, Andria; Goodman, Catherine; Naanyu, Violet; Koech, Beatrice; Obala, Andrew; O'Meara, Wendy Prudhomme

    2013-01-01

    Background. The common symptoms of malaria reduce the specificity of clinical diagnosis. Presumptive treatment is conventional but can lead to overdiagnosis of malaria, delay of appropriate treatment, overprescription of antimalarials, and drug resistance. Routine use of diagnostic tests can address many of these concerns. Though treatment is often procured from retailers, there is low availability of rapid diagnostic tests for malaria (MRDTs), a simple, inexpensive, and accurate diagnostic solution. We know little about the challenges to expanding access to diagnostics through these outlets. Methods. To understand the perceptions of the benefits and challenges to selling rapid diagnostic tests for malaria, we conducted focus group discussions with antimalarial retailers who serve the residents of the Webuye Health and Demographic Surveillance Site in western Kenya. Results. Medicine retailers perceived MRDTs to be beneficial to their customers and businesses but also included cost, fear of the tests, risks of self-treatment, and regulatory concerns among the challenges to using and selling MRDTs. Conclusion. MRDTs represent a viable approach to increase access to malaria diagnostic testing. Medicine retailers are eager for MRDTs to be made available to them. However, certain challenges remain to implementation in retail outlets and should be addressed in advance.

  4. Diagnostic performance characteristics of a rapid field test for anthrax in cattle.

    PubMed

    Muller, Janine; Gwozdz, Jacek; Hodgeman, Rachel; Ainsworth, Catherine; Kluver, Patrick; Czarnecki, Jill; Warner, Simone; Fegan, Mark

    2015-07-01

    Although diagnosis of anthrax can be made in the field with a peripheral blood smear, and in the laboratory with bacterial culture or molecular based tests, these tests require either considerable experience or specialised equipment. Here we report on the evaluation of the diagnostic sensitivity and specificity of a simple and rapid in-field diagnostic test for anthrax, the anthrax immunochromatographic test (AICT). The AICT detects the protective antigen (PA) component of the anthrax toxin present within the blood of an animal that has died from anthrax. The test provides a result in 15min and offers the advantage of avoiding the necessity for on-site necropsy and subsequent occupational risks and environmental contamination. The specificity of the test was determined by testing samples taken from 622 animals, not infected with Bacillus anthracis. Diagnostic sensitivity was estimated on samples taken from 58 animals, naturally infected with B. anthracis collected over a 10-year period. All samples used to estimate the diagnostic sensitivity and specificity of the AICT were also tested using the gold standard of bacterial culture. The diagnostic specificity of the test was estimated to be 100% (99.4-100%; 95% CI) and the diagnostic sensitivity was estimated to be 93.1% (83.3-98.1%; 95% CI) (Clopper-Pearson method). Four samples produced false negative AICT results. These were among 9 samples, all of which tested positive for B. anthracis by culture, where there was a time delay between collection and testing of >48h and/or the samples were collected from animals that were >48h post-mortem. A statistically significant difference (P<0.001; Fishers exact test) was found between the ability of the AICT to detect PA in samples from culture positive animals <48h post-mortem, 49 of 49, Se=100% (92.8-100%; 95% CI) compared with samples tested >48h post-mortem 5 of 9 Se=56% (21-86.3%; 95% CI) (Clopper-Pearson method). Based upon these results a post hoc cut-off for use of the AICT of 48h post-mortem was applied, Se=100% (92.8-100%; 95% CI) and Sp=100% (99.4-100%; 95% CI). The high diagnostic sensitivity and specificity and the simplicity of the AICT enables it to be used for active surveillance in areas with a history of anthrax, or used as a preliminary tool in investigating sudden, unexplained death in cattle. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. [Current status and clinical application prospect of Akabane's test].

    PubMed

    Wang, Wenjie; Du, Yanjun

    2016-06-12

    The Akabane's test is one of the meridian diagnostic methods. Compared with the current meridian diagnostic methods, it has the advantages of convenience and efficiency, but it also has several disadvantages such as the accuracy is difficult to control, the outcome interpretation is limited, etc. In this paper, the influence factors of Akabane's test were analyzed one by one, especially proposed personal opinion on outcome interpretation, which could ascertain the location and nature of disease, leading to disease syndrome. With accurate syndrome, the treatment plan could be established. The application prospect of Akabane's test was initially explored, and it was proposed that wearable automation equipment could be one of the development directions.

  6. Comparing the diagnostic properties of skin scraping, adhesive tape, and dermoscopy in diagnosing scabies.

    PubMed

    Abdel-Latif, Azmy A; Elshahed, Ahmad R; Salama, Omar A; Elsaie, Mohamed L

    2018-06-01

    Scabies is a contagious skin infestation that mainly presents with itching at night and skin burrows that are visible to the naked eye. Diagnosing scabies with dermoscopy is still a matter of controversy. The aim of our study was to compare the diagnostic properties of adhesive tape, skin scraping, and dermoscopy in diagnosing scabies. One hundred patients with clinical presumptive diagnoses of scabies underwent skin scraping, adhesive tape testing, and dermoscopic examination. Each diagnostic procedure was performed on three different areas. Comparing the diagnostic properties of the three methods, the adhesive tape test was the most sensitive method for diagnosing scabies. Sixteen cases (16.0%) were definitely diagnosed as scabies using the adhesive tape test detecting the presence of mites or their eggs. Only 10 cases (10.0%) were definitely diagnosed as scabies using the skin scraping test detecting mites or their eggs. Dermoscopic examination suggested a diagnosis of scabies in 22 cases (22.0%), of which only 10 were definitely diagnosed as scabies by detecting mites using the adhesive tape test, skin scraping, or both. The diagnosis of scabies can only be confirmed by seeing mites. The adhesive tape test and skin scraping procedure have high specificity in diagnosing scabies, but their low sensitivity cannot exclude the possibility of scabies. Dermoscopy-guided tape testing can be a helpful tool for better diagnosis of scabies.

  7. A robust method using propensity score stratification for correcting verification bias for binary tests

    PubMed Central

    He, Hua; McDermott, Michael P.

    2012-01-01

    Sensitivity and specificity are common measures of the accuracy of a diagnostic test. The usual estimators of these quantities are unbiased if data on the diagnostic test result and the true disease status are obtained from all subjects in an appropriately selected sample. In some studies, verification of the true disease status is performed only for a subset of subjects, possibly depending on the result of the diagnostic test and other characteristics of the subjects. Estimators of sensitivity and specificity based on this subset of subjects are typically biased; this is known as verification bias. Methods have been proposed to correct verification bias under the assumption that the missing data on disease status are missing at random (MAR), that is, the probability of missingness depends on the true (missing) disease status only through the test result and observed covariate information. When some of the covariates are continuous, or the number of covariates is relatively large, the existing methods require parametric models for the probability of disease or the probability of verification (given the test result and covariates), and hence are subject to model misspecification. We propose a new method for correcting verification bias based on the propensity score, defined as the predicted probability of verification given the test result and observed covariates. This is estimated separately for those with positive and negative test results. The new method classifies the verified sample into several subsamples that have homogeneous propensity scores and allows correction for verification bias. Simulation studies demonstrate that the new estimators are more robust to model misspecification than existing methods, but still perform well when the models for the probability of disease and probability of verification are correctly specified. PMID:21856650

  8. Towards a Theory of Diagnosis in Second and Foreign Language Assessment: Insights from Professional Practice across Diverse Fields

    ERIC Educational Resources Information Center

    Alderson, J. Charles; Brunfaut, Tineke; Harding, Luke

    2015-01-01

    Diagnostic language assessment has received increased research interest in recent years, with particular attention on methods through which diagnostic information can be gleaned from standardized proficiency tests. However, diagnostic procedures in the broader sense have been inadequately theorized to date, with the result that there is still…

  9. Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design.

    PubMed

    Kim, Eunhee; Zhang, Zheng; Wang, Youdan; Zeng, Donglin

    2014-12-01

    Receiver operating characteristic (ROC) analysis is widely used to evaluate the performance of diagnostic tests with continuous or ordinal responses. A popular study design for assessing the accuracy of diagnostic tests involves multiple readers interpreting multiple diagnostic test results, called the multi-reader, multi-test design. Although several different approaches to analyzing data from this design exist, few methods have discussed the sample size and power issues. In this article, we develop a power formula to compare the correlated areas under the ROC curves (AUC) in a multi-reader, multi-test design. We present a nonparametric approach to estimate and compare the correlated AUCs by extending DeLong et al.'s (1988, Biometrics 44, 837-845) approach. A power formula is derived based on the asymptotic distribution of the nonparametric AUCs. Simulation studies are conducted to demonstrate the performance of the proposed power formula and an example is provided to illustrate the proposed procedure. © 2014, The International Biometric Society.

  10. More Than Just Accuracy: A Novel Method to Incorporate Multiple Test Attributes in Evaluating Diagnostic Tests Including Point of Care Tests.

    PubMed

    Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole

    2016-01-01

    Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.

  11. Pattern classifier for health monitoring of helicopter gearboxes

    NASA Technical Reports Server (NTRS)

    Chin, Hsinyung; Danai, Kourosh; Lewicki, David G.

    1993-01-01

    The application of a newly developed diagnostic method to a helicopter gearbox is demonstrated. This method is a pattern classifier which uses a multi-valued influence matrix (MVIM) as its diagnostic model. The method benefits from a fast learning algorithm, based on error feedback, that enables it to estimate gearbox health from a small set of measurement-fault data. The MVIM method can also assess the diagnosability of the system and variability of the fault signatures as the basis to improve fault signatures. This method was tested on vibration signals reflecting various faults in an OH-58A main rotor transmission gearbox. The vibration signals were then digitized and processed by a vibration signal analyzer to enhance and extract various features of the vibration data. The parameters obtained from this analyzer were utilized to train and test the performance of the MVIM method in both detection and diagnosis. The results indicate that the MVIM method provided excellent detection results when the full range of faults effects on the measurements were included in training, and it had a correct diagnostic rate of 95 percent when the faults were included in training.

  12. Identification misconception of primary school teacher education students in changes of matters using a five-tier diagnostic test

    NASA Astrophysics Data System (ADS)

    Bayuni, T. C.; Sopandi, W.; Sujana, A.

    2018-05-01

    This research was conducted on third grade students (III) semester six, with sample number 84 respondents. The method used in this research is descriptive method. This article identifies the misconceptions of Primary School Teacher Education students by using a five tier diagnostic test research instrument, a question adapted to three chemical representations accompanied by an open reason and a level of confidence in the choice of answers. The categorization of the five tier diagnostic test scoring is divided into four namely, understand the concept, lack of concept, misconception and not understand the concept. Questionnaire in the form of a closed questionnaire is used to determine the factors that cause misconception. The data obtained is misconception has the highest percentage on the concept of substance properties and changes in its form. The highest incidence of misconceptions is due to self-factors. The conclusion is that five tier diagnostic tests can be used to uncover misconceptions of elementary school teachers and assist teachers in presenting lesson material tailored to the chemical representation so that students can understand the concept of the nature of matter and change its form well.

  13. Molecular and Nonmolecular Diagnostic Methods for Invasive Fungal Infections

    PubMed Central

    Arvanitis, Marios; Anagnostou, Theodora; Fuchs, Beth Burgwyn; Caliendo, Angela M.

    2014-01-01

    SUMMARY Invasive fungal infections constitute a serious threat to an ever-growing population of immunocompromised individuals and other individuals at risk. Traditional diagnostic methods, such as histopathology and culture, which are still considered the gold standards, have low sensitivity, which underscores the need for the development of new means of detecting fungal infectious agents. Indeed, novel serologic and molecular techniques have been developed and are currently under clinical evaluation. Tests like the galactomannan antigen test for aspergillosis and the β-glucan test for invasive Candida spp. and molds, as well as other antigen and antibody tests, for Cryptococcus spp., Pneumocystis spp., and dimorphic fungi, have already been established as important diagnostic approaches and are implemented in routine clinical practice. On the other hand, PCR and other molecular approaches, such as matrix-assisted laser desorption ionization (MALDI) and fluorescence in situ hybridization (FISH), have proved promising in clinical trials but still need to undergo standardization before their clinical use can become widespread. The purpose of this review is to highlight the different diagnostic approaches that are currently utilized or under development for invasive fungal infections and to identify their performance characteristics and the challenges associated with their use. PMID:24982319

  14. Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

    PubMed

    Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C

    2007-01-01

    After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.

  15. A 'difficult' insect allergy patient: reliable history of a sting, but all testing negative.

    PubMed

    Tracy, James M; Olsen, Jonathan A; Carlson, John

    2015-08-01

    Few conditions are as treatable as allergy to stinging insects, with venom immunotherapy (VIT) providing up to 98% protection to subsequent stings. The challenge with VIT is not in the treatment, but in the diagnosis. To offer VIT, one must determine a history of a systemic reaction to a stinging insect in conjunction with the presence venom-specific IgE. Current diagnostic methods, although sensitive and specific, are imperfect, and some newer testing options are not widely available. A conundrum occasionally faced is the patient with a reliable and compelling history of a systemic allergic reaction yet negative venom-specific testing. This diagnostic dilemma presents an opportunity to consider possible causes for this diagnostic challenge. Our evolving understanding of the role of occult mast cell disease may begin to help us understand this situation and develop appropriate management strategies. Venom-specific skin testing has long been the cornerstone of the evaluation of venom sensitivity and is often combined with in-vitro assays to add clarity, but even these occasionally may fall short. Exploring novel venom diagnostic testing methods may help to fill in some of the diagnostic gaps. Do currently available venom vaccines contain all the key venom species? Are there enough differences between insect species that we may simply be missing the relevant allergens? What is the significance of the antigenicity of carbohydrate moieties in venoms? What is the role of recombinant venom extracts? VIT is the definitive treatment for insect allergic individuals. To utilize VIT, identification of the relevant Hymenoptera is necessary. Unfortunately, this cannot always be accomplished. This deficiency can have several causes: a potential comorbid condition such as occult mast cell disease, limitations of currently available diagnostic resources, or testing vaccines with an insufficient coverage of relevant venom allergens. Exploring these potential causes may help to provide important insight into this important diagnostic conundrum. The use of a case report may help clarify this challenge.

  16. Diagnostic accuracy and cost-effectiveness of alternative methods for detection of soil-transmitted helminths in a post-treatment setting in western Kenya.

    PubMed

    Assefa, Liya M; Crellen, Thomas; Kepha, Stella; Kihara, Jimmy H; Njenga, Sammy M; Pullan, Rachel L; Brooker, Simon J

    2014-05-01

    This study evaluates the diagnostic accuracy and cost-effectiveness of the Kato-Katz and Mini-FLOTAC methods for detection of soil-transmitted helminths (STH) in a post-treatment setting in western Kenya. A cost analysis also explores the cost implications of collecting samples during school surveys when compared to household surveys. Stool samples were collected from children (n = 652) attending 18 schools in Bungoma County and diagnosed by the Kato-Katz and Mini-FLOTAC coprological methods. Sensitivity and additional diagnostic performance measures were analyzed using Bayesian latent class modeling. Financial and economic costs were calculated for all survey and diagnostic activities, and cost per child tested, cost per case detected and cost per STH infection correctly classified were estimated. A sensitivity analysis was conducted to assess the impact of various survey parameters on cost estimates. Both diagnostic methods exhibited comparable sensitivity for detection of any STH species over single and consecutive day sampling: 52.0% for single day Kato-Katz; 49.1% for single-day Mini-FLOTAC; 76.9% for consecutive day Kato-Katz; and 74.1% for consecutive day Mini-FLOTAC. Diagnostic performance did not differ significantly between methods for the different STH species. Use of Kato-Katz with school-based sampling was the lowest cost scenario for cost per child tested ($10.14) and cost per case correctly classified ($12.84). Cost per case detected was lowest for Kato-Katz used in community-based sampling ($128.24). Sensitivity analysis revealed the cost of case detection for any STH decreased non-linearly as prevalence rates increased and was influenced by the number of samples collected. The Kato-Katz method was comparable in diagnostic sensitivity to the Mini-FLOTAC method, but afforded greater cost-effectiveness. Future work is required to evaluate the cost-effectiveness of STH surveillance in different settings.

  17. Methods for the Joint Meta-Analysis of Multiple Tests

    ERIC Educational Resources Information Center

    Trikalinos, Thomas A.; Hoaglin, David C.; Small, Kevin M.; Terrin, Norma; Schmid, Christopher H.

    2014-01-01

    Existing methods for meta-analysis of diagnostic test accuracy focus primarily on a single index test. We propose models for the joint meta-analysis of studies comparing multiple index tests on the same participants in paired designs. These models respect the grouping of data by studies, account for the within-study correlation between the tests'…

  18. Multiplex PCR Tests for Detection of Pathogens Associated with Gastroenteritis

    PubMed Central

    Zhang, Hongwei; Morrison, Scott; Tang, Yi-Wei

    2016-01-01

    Synopsis A wide range of enteric pathogens can cause infectious gastroenteritis. Conventional diagnostic algorithms including culture, biochemical identification, immunoassay and microscopic examination are time consuming and often lack sensitivity and specificity. Advances in molecular technology have as allowed its use as clinical diagnostic tools. Multiplex PCR based testing has made its way to gastroenterology diagnostic arena in recent years. In this article we present a review of recent laboratory developed multiplex PCR tests and current commercial multiplex gastrointestinal pathogen tests. We will focus on two FDA cleared commercial syndromic multiplex tests: Luminex xTAG GPP and Biofire FimArray GI test. These multiplex tests can detect and identify multiple enteric pathogens in one test and provide results within hours. Multiplex PCR tests have shown superior sensitivity to conventional methods for detection of most pathogens. The high negative predictive value of these multiplex tests has led to the suggestion that they be used as screening tools especially in outbreaks. Although the clinical utility and benefit of multiplex PCR test are to be further investigated, implementing these multiplex PCR tests in gastroenterology diagnostic algorithm has the potential to improve diagnosis of infectious gastroenteritis. PMID:26004652

  19. Remediation of petroleum hydrocarbon-contaminated sites by DNA diagnosis-based bioslurping technology.

    PubMed

    Kim, Seungjin; Krajmalnik-Brown, Rosa; Kim, Jong-Oh; Chung, Jinwook

    2014-11-01

    The application of effective remediation technologies can benefit from adequate preliminary testing, such as in lab-scale and Pilot-scale systems. Bioremediation technologies have demonstrated tremendous potential with regards to cost, but they cannot be used for all contaminated sites due to limitations in biological activity. The purpose of this study was to develop a DNA diagnostic method that reduces the time to select contaminated sites that are good candidates for bioremediation. We applied an oligonucleotide microarray method to detect and monitor genes that lead to aliphatic and aromatic degradation. Further, the bioremediation of a contaminated site, selected based on the results of the genetic diagnostic method, was achieved successfully by applying bioslurping in field tests. This gene-based diagnostic technique is a powerful tool to evaluate the potential for bioremediation in petroleum hydrocarbon contaminated soil. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Benefits and challenges of molecular diagnostics for childhood tuberculosis.

    PubMed

    Gutierrez, Cristina

    2016-12-01

    Expanding tuberculosis (TB)-diagnostic services, including access to rapid tests, is a World Health Organization (WHO) strategy to accelerate progress toward ending TB. Faster and more sensitive molecular tests capable of diagnosing TB and drug-resistant TB have the technical capacity to address limitations associated with smears and cultures by increasing accuracy and shortening turnaround times as compared with those of these conventional laboratory methods. Nucleic acid amplification assays used to detect and analyze Mycobacterium tuberculosis (MTB)-complex nucleic acids can be used directly on specimens from patients suspected of having TB. Recently, several commercial molecular tests were developed to detect MTB and determine the drug resistance (DR) based on detection of specific genetic mutations conferring resistance. The first to be endorsed by the WHO was molecular line-probe assay technology. This test uses polymerase chain reaction (PCR) and reverse-hybridization methods to rapidly identify MTB and DR-related mutations simultaneously. More recently, the WHO endorsed Xpert MTB/RIF, Cepheid Inc, CA, USA, a fully automated assay used for TB diagnosis that relies upon PCR techniques for detection of TB and rifampicin resistance-related mutations. Other promising molecular TB assays for simplifying PCR-based testing protocols and increasing their accuracy are under development and evaluation. Although we lack a practical gold standard for the diagnosis of childhood TB, its bacteriological confirmation is always recommended to be sought whenever possible prior to a diagnostic decision being made. Conventional diagnostic laboratory TB tests are less efficient for children as compared with adults, because sufficient sputum samples are more difficult to collect from infants and young children, and their disease is often paucibacillary, resulting in smear-negative disease. These inherent challenges associated with childhood TB are due to immunological- and pathophysiological-response differences relative to those observed in adults. Several recent meta-analyses showed low sensitivity estimates of PCR-based TB assays for paucibacillary forms of TB (extrapulmonary TB and smear-negative pulmonary disease), which represent the vast majority of childhood TB cases. Despite the lack of evidence regarding use of the rapid molecular assays to identify TB and detect DR in children, and due to the clinical nature of childhood TB, TB-expert groups recommend including rapid methods for TB identification and DR detection in diagnostic algorithms for children suspected of both smear-positive and -negative pulmonary or extrapulmonary TB, both with or without human immunodeficiency virus (HIV)-coinfection, when combined with standard methods (including clinical, microbiological, and radiological assessment) for diagnosing active TB and conventional DR. Since 2011, the WHO has specifically recommended use of the Xpert MTB/RIF test as an initial diagnostic tool for children with suspected HIV-associated TB or multidrug-resistant TB based on successful treatment data related to adults. Implementation of the rapid molecular assays for rapid detection of TB and DR should occur in laboratories with proven capability to run molecular tests and where quality control systems are implemented. Molecular approaches should be more largely tested in children, given their status as the group in whom the diagnostic dilemma is most pronounced. These tests should also be included in specific childhood TB diagnostic algorithms adapted to the local/national context in combination with other strategies for improving diagnostics, including more effective specimen collection. Copyright © 2016.

  1. Evaluation of the diagnostic yield of dental radiography and cone-beam computed tomography for the identification of anatomic landmarks in small to medium-sized brachycephalic dogs.

    PubMed

    Döring, Sophie; Arzi, Boaz; Barich, Catherine R; Hatcher, David C; Kass, Philip H; Verstraete, Frank J M

    2018-01-01

    OBJECTIVE To evaluate the diagnostic yield of dental radiography (Rad method) and 3 cone-beam CT (CBCT) methods for the identification of predefined anatomic landmarks in brachycephalic dogs. ANIMALS 19 client-owned brachycephalic dogs admitted for evaluation and treatment of dental disease. PROCEDURES 26 predefined anatomic landmarks were evaluated separately by use of the RAD method and 3 CBCT software modules (serial CBCT slices and custom cross sections, tridimensional rendering, and reconstructed panoramic views). A semiquantitative scoring system was used, and mean scores were calculated for each anatomic landmark and imaging method. The Friedman test was used to evaluate values for significant differences in diagnostic yield. For values that were significant, the Wilcoxon signed rank test was used with the Bonferroni-Holm multiple comparison adjustment to determine significant differences among each of the 6 possible pairs of diagnostic methods. RESULTS Differences of diagnostic yield among the Rad and 3 CBCT methods were significant for 19 of 26 anatomic landmarks. For these landmarks, Rad scores were significantly higher than scores for reconstructed panoramic views for 4 of 19 anatomic landmarks, but Rad scores were significantly lower than scores for reconstructed panoramic views for 8 anatomic landmarks, tridimensional rendering for 18 anatomic landmarks, and serial CBCT slices and custom cross sections for all 19 anatomic landmarks. CONCLUSIONS AND CLINICAL RELEVANCE CBCT methods were better suited than dental radiography for the identification of anatomic landmarks in brachycephalic dogs. Results of this study can serve as a basis for CBCT evaluation of dental disorders in brachycephalic dogs.

  2. Commercial Molecular Tests for Fungal Diagnosis from a Practical Point of View.

    PubMed

    Lackner, Michaela; Lass-Flörl, Cornelia

    2017-01-01

    The increasing interest in molecular diagnostics is a result of tremendously improved knowledge on fungal infections in the past 20 years and the rapid development of new methods, in particular polymerase chain reaction. High expectations have been placed on molecular diagnostics, and the number of laboratories now using the relevant technology is rapidly increasing-resulting in an obvious need for standardization and definition of laboratory organization. In the past 10 years, multiple new molecular tools were marketed for the detection of DNA, antibodies, cell wall components, or other antigens. In contrast to classical culture methods, molecular methods do not detect a viable organisms, but only molecules which indicate its presence; this can be nucleic acids, cell components (antigens), or antibodies (Fig. 1). In this chapter, an overview is provided on commercially available detection tools, their strength and how to use them. A main focus is laid on providing tips and tricks that make daily life easier. We try to focus and mention methodical details which are not highlighted in the manufacturer's instructions of these test kits, but are based on our personal experience in the laboratory. Important to keep in mind is that molecular tools cannot replace culture, microscopy, or a critical view on patients' clinical history, signs, and symptoms, but provide a valuable add on tool. Diagnosis should not be based solely on a molecular test, but molecular tools might deliver an important piece of information that helps matching the diagnostic puzzle to a diagnosis, in particular as few tests are in vitro diagnostic tests (IVD) or only part of the whole test carries the IVD certificate (e.g., DNA extraction is often not included). Please be aware that the authors do not claim to provide a complete overview on all commercially available diagnostic assays being currently marketed for fungal detection, as those are subject to constant change. A main focus is put on commonly used panfungal assays and pathogen-specific assays, including Aspergillus-specific, Candida-specific, Cryptococcus specific, Histoplasma-specific, and Pneumocystis-specific assays. Assays are categorized according to their underlying principle in either antigen-detecting or antibody-detecting or DNA-detecting (Fig. 1). Other non-DNA-detecting nucleic acid methods such as FISH and PNA FISH are not summarized in this chapter and an overview on test performance, common false positives, and the clinical evaluation of commercial tests in studies is provided already in a previous book series by Javier Yugueros Marcos and David H. Pincus (Marcos and Pincus, Methods Mol Biol 968:25-54, 2013).

  3. Diffusion of Molecular Diagnostic Lung Cancer Tests: A Survey of German Oncologists

    PubMed Central

    Steffen, Julius Alexander

    2014-01-01

    This study was aimed at examining the diffusion of diagnostic lung cancer tests in Germany. It was motivated by the high potential of detecting and targeting oncogenic drivers. Recognizing that the diffusion of diagnostic tests is a conditio sine qua non for the success of personalized lung cancer therapies, this study analyzed the diffusion of epidermal growth factor receptor (EGFR) and anaplastic lymphoma kinase (ALK) tests in Germany. Qualitative and quantitative research strategies were combined in a mixed-method design. A literature review and subsequent Key Opinion Leader interviews identified a set of qualitative factors driving the diffusion process, which were then translated into an online survey. The survey was conducted among a sample of 961 oncologists (11.34% response rate). The responses were analyzed in a multiple linear regression which identified six statistically significant factors driving the diffusion of molecular diagnostic lung cancer tests: reimbursement, attitude towards R&D, information self-assessment, perceived attitudes of colleagues, age and test-pathway strategies. Besides the important role of adequate reimbursement and relevant guidelines, the results of this study suggest that an increasing usage of test-pathway strategies, especially in an office-based setting, can increase the diffusion of molecular diagnostic lung cancer tests in the future. PMID:25562146

  4. An objective method and measuring equipment for noise control and acoustic diagnostics of motorcars. [acoustic diagnostics on automobile engines

    NASA Technical Reports Server (NTRS)

    Kacprowski, J.; Motylewski, J.; Miazga, J.

    1974-01-01

    An objective method and apparatus for noise control and acoustic diagnostics of motorcar engines are reported. The method and apparatus let us know whether the noisiness of the vehicle under test exceeds the admissible threshold levels given by appropriate standards and if so what is the main source of the excessive noise. The method consists in measuring both the overall noise level and the sound pressure levels in definite frequency bands while the engine speed is controlled as well and may be fixed at prescribed values. Whenever the individually adjusted threshold level has been exceeded in any frequency band, a self-sustaining control signal is sent.

  5. DIAGNOSTIC ACCURACY OF PHYSICAL EXAMINATION TESTS OF THE ANKLE/FOOT COMPLEX: A SYSTEMATIC REVIEW

    PubMed Central

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren

    2013-01-01

    Background: Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. Purpose: The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. Methods: A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Results: Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Conclusion: Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. Level of Evidence: 3a PMID:24175128

  6. Medical microbiology: laboratory diagnosis of invasive pneumococcal disease.

    PubMed

    Werno, Anja M; Murdoch, David R

    2008-03-15

    The laboratory diagnosis of invasive pneumococcal disease (IPD) continues to rely on culture-based methods that have been used for many decades. The most significant recent developments have occurred with antigen detection assays, whereas the role of nucleic acid amplification tests has yet to be fully clarified. Despite developments in laboratory diagnostics, a microbiological diagnosis is still not made in most cases of IPD, particularly for pneumococcal pneumonia. The limitations of existing diagnostic tests impact the ability to obtain accurate IPD burden data and to assess the effectiveness of control measures, such as vaccination, in addition to the ability to diagnose IPD in individual patients. There is an urgent need for improved diagnostic tests for pneumococcal disease--especially tests that are suitable for use in underresourced countries.

  7. [Inappropriate test methods in allergy].

    PubMed

    Kleine-Tebbe, J; Herold, D A

    2010-11-01

    Inappropriate test methods are increasingly utilized to diagnose allergy. They fall into two categories: I. Tests with obscure theoretical basis, missing validity and lacking reproducibility, such as bioresonance, electroacupuncture, applied kinesiology and the ALCAT-test. These methods lack both the technical and clinical validation needed to justify their use. II. Tests with real data, but misleading interpretation: Detection of IgG or IgG4-antibodies or lymphocyte proliferation tests to foods do not allow to separate healthy from diseased subjects, neither in case of food intolerance, allergy or other diagnoses. The absence of diagnostic specificity induces many false positive findings in healthy subjects. As a result unjustified diets might limit quality of life and lead to malnutrition. Proliferation of lymphocytes in response to foods can show elevated rates in patients with allergies. These values do not allow individual diagnosis of hypersensitivity due to their broad variation. Successful internet marketing, infiltration of academic programs and superficial reporting by the media promote the popularity of unqualified diagnostic tests; also in allergy. Therefore, critical observation and quick analysis of and clear comments to unqualified methods by the scientific medical societies are more important than ever.

  8. [Contemporary methods for preterm labor diagnostics].

    PubMed

    Kolev, N; Kovachev, E; Ivanov, S; Kornovski, Y; Tsvetkov, K; Angelova, M; Tsonev, A; Ismail, E

    2013-01-01

    Authors track current trends in preterm labor diagnostics. The emphasis is laid on biochemical tests for examination of fibronectin (fFN) and insulin-like growth factor-binding protein (IGFBP-1) in cervical and vaginal secretions, as well as ultrasound assessment of cervical length.

  9. Invasive candidiasis: future directions in non-culture based diagnosis.

    PubMed

    Posch, Wilfried; Heimdörfer, David; Wilflingseder, Doris; Lass-Flörl, Cornelia

    2017-09-01

    Delayed initial antifungal therapy is associated with high mortality rates caused by invasive candida infections, since accurate detection of the opportunistic pathogenic yeast and its identification display a diagnostic challenge. diagnosis of candida infections relies on time-consuming methods such as blood cultures, serologic and histopathologic examination. to allow for fast detection and characterization of invasive candidiasis, there is a need to improve diagnostic tools. trends in diagnostics switch to non-culture-based methods, which allow specified diagnosis within significantly shorter periods of time in order to provide early and appropriate antifungal treatment. Areas covered: within this review comprise novel pathogen- and host-related testing methods, e.g. multiplex-PCR analyses, T2 magnetic resonance, fungus-specific DNA microarrays, microRNA characterization or analyses of IL-17 as biomarker for early detection of invasive candidiasis. Expert commentary: Early recognition and diagnosis of fungal infections is a key issue for improved patient management. As shown in this review, a broad range of novel molecular based tests for the detection and identification of Candida species is available. However, several assays are in-house assays and lack standardization, clinical validation as well as data on sensitivity and specificity. This underscores the need for the development of faster and more accurate diagnostic tests.

  10. A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

    NASA Astrophysics Data System (ADS)

    Nam, Kyoung Won; Kim, In Young; Kang, Ho Chul; Yang, Hee Kyung; Yoon, Chang Ki; Hwang, Jeong Min; Kim, Young Jae; Kim, Tae Yun; Kim, Kwang Gi

    2012-10-01

    Accurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 < 0.05), but no statistically significant difference between the proposed method and the Krimsky test (p = 0.912 > 0.05). The measurements of the two methods were highly correlated (r = 0.969, p < 0.05). From the experimental results, we believe that the proposed diagnostic method has the potential to be a diagnostic tool that measures the physical disorder of the human eye to diagnose non-invasively the severity of strabismus.

  11. The impact of a computerised test of attention and activity (QbTest) on diagnostic decision-making in children and young people with suspected attention deficit hyperactivity disorder: single-blind randomised controlled trial.

    PubMed

    Hollis, Chris; Hall, Charlotte L; Guo, Boliang; James, Marilyn; Boadu, Janet; Groom, Madeleine J; Brown, Nikki; Kaylor-Hughes, Catherine; Moldavsky, Maria; Valentine, Althea Z; Walker, Gemma M; Daley, David; Sayal, Kapil; Morriss, Richard

    2018-04-26

    Diagnosis of attention deficit hyperactivity disorder (ADHD) relies on subjective methods which can lead to diagnostic uncertainty and delay. This trial evaluated the impact of providing a computerised test of attention and activity (QbTest) report on the speed and accuracy of diagnostic decision-making in children with suspected ADHD. Randomised, parallel, single-blind controlled trial in mental health and community paediatric clinics in England. Participants were 6-17 years-old and referred for ADHD diagnostic assessment; all underwent assessment-as-usual, plus QbTest. Participants and their clinician were randomised to either receive the QbTest report immediately (QbOpen group) or the report was withheld (QbBlind group). The primary outcome was number of consultations until a diagnostic decision confirming/excluding ADHD within 6-months from baseline. Health economic cost-effectiveness and cost utility analysis was conducted. Assessing QbTest Utility in ADHD: A Randomised Controlled Trial was registered at ClinicalTrials.gov (https://clinicaltrials.gov/ct2/show/NCT02209116). One hundred and thirty-two participants were randomised to QbOpen group (123 analysed) and 135 to QbBlind group (127 analysed). Clinicians with access to the QbTest report (QbOpen) were more likely to reach a diagnostic decision about ADHD (hazard ratio 1.44, 95% CI 1.04-2.01). At 6-months, 76% of those with a QbTest report had received a diagnostic decision, compared with 50% without. QbTest reduced appointment length by 15% (time ratio 0.85, 95% CI 0.77-0.93), increased clinicians' confidence in their diagnostic decisions (odds ratio 1.77, 95% CI 1.09-2.89) and doubled the likelihood of excluding ADHD. There was no difference in diagnostic accuracy. Health economic analysis showed a position of strict dominance; however, cost savings were small suggesting that the impact of providing the QbTest report within this trial can best be viewed as 'cost neutral'. QbTest may increase the efficiency of ADHD assessment pathway allowing greater patient throughput with clinicians reaching diagnostic decisions faster without compromising diagnostic accuracy. © 2018 The Authors. Journal of Child Psychology and Psychiatry published by John Wiley & Sons Ltd on behalf of Association for Child and Adolescent Mental Health.

  12. An audit of Cryptosporidium and Giardia detection in Scottish National Health Service Diagnostic Microbiology Laboratories.

    PubMed

    Alexander, C L; Currie, S; Pollock, K; Smith-Palmer, A; Jones, B L

    2017-06-01

    Giardia duodenalis and Cryptosporidium species are protozoan parasites capable of causing gastrointestinal disease in humans and animals through the ingestion of infective faeces. Whereas Cryptosporidium species can be acquired locally or through foreign travel, there is the mis-conception that giardiasis is considered to be largely travel-associated, which results in differences in laboratory testing algorithms. In order to determine the level of variation in testing criteria and detection methods between diagnostic laboratories for both pathogens across Scotland, an audit was performed. Twenty Scottish diagnostic microbiology laboratories were invited to participate with questions on sample acceptance criteria, testing methods, testing rates and future plans for pathogen detection. Reponses were received from 19 of the 20 laboratories representing each of the 14 territorial Health Boards. Detection methods varied between laboratories with the majority performing microscopy, one using a lateral flow immunochromatographic antigen assay, another using a manually washed plate-based enzyme immunoassay (EIA) and one laboratory trialling a plate-based EIA automated with an EIA plate washer. Whereas all laboratories except one screened every stool for Cryptosporidium species, an important finding was that significant variation in the testing algorithm for detecting Giardia was noted with only four laboratories testing all diagnostic stools. The most common criteria were 'travel history' (11 laboratories) and/or 'when requested' (14 laboratories). Despite only a small proportion of stools being examined in 15 laboratories for Giardia (2%-18% of the total number of stools submitted), of interest is the finding that a higher positivity rate was observed for Giardia than Cryptosporidium in 10 of these 15 laboratories. These findings highlight that the underreporting of Giardia in Scotland is likely based on current selection and testing algorithms.

  13. Assessment of postural balance function.

    PubMed

    Kostiukow, Anna; Rostkowska, Elzbieta; Samborski, Włodzimierz

    2009-01-01

    Postural balance is defined as the ability to stand unassisted without falling. Examination of the patient's postural balance function is a difficult diagnostic task. Most of the balance tests used in medicine provide incomplete information on this coordination ability of the human body. The aim of this study was to review methods of assessment of the patient's postural balance function, including various tests used in medical diagnostics centers.

  14. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  15. Clinical evaluation and validation of laboratory methods for the diagnosis of Bordetella pertussis infection: Culture, polymerase chain reaction (PCR) and anti-pertussis toxin IgG serology (IgG-PT)

    PubMed Central

    Cassiday, Pamela K.; Pawloski, Lucia C.; Tatti, Kathleen M.; Martin, Monte D.; Briere, Elizabeth C.; Tondella, M. Lucia; Martin, Stacey W.

    2018-01-01

    Introduction The appropriate use of clinically accurate diagnostic tests is essential for the detection of pertussis, a poorly controlled vaccine-preventable disease. The purpose of this study was to estimate the sensitivity and specificity of different diagnostic criteria including culture, multi-target polymerase chain reaction (PCR), anti-pertussis toxin IgG (IgG-PT) serology, and the use of a clinical case definition. An additional objective was to describe the optimal timing of specimen collection for the various tests. Methods Clinical specimens were collected from patients with cough illness at seven locations across the United States between 2007 and 2011. Nasopharyngeal and blood specimens were collected from each patient during the enrollment visit. Patients who had been coughing for ≤ 2 weeks were asked to return in 2–4 weeks for collection of a second, convalescent blood specimen. Sensitivity and specificity of each diagnostic test were estimated using three methods—pertussis culture as the “gold standard,” composite reference standard analysis (CRS), and latent class analysis (LCA). Results Overall, 868 patients were enrolled and 13.6% were B. pertussis positive by at least one diagnostic test. In a sample of 545 participants with non-missing data on all four diagnostic criteria, culture was 64.0% sensitive, PCR was 90.6% sensitive, and both were 100% specific by LCA. CRS and LCA methods increased the sensitivity estimates for convalescent serology and the clinical case definition over the culture-based estimates. Culture and PCR were most sensitive when performed during the first two weeks of cough; serology was optimally sensitive after the second week of cough. Conclusions Timing of specimen collection in relation to onset of illness should be considered when ordering diagnostic tests for pertussis. Consideration should be given to including IgG-PT serology as a confirmatory test in the Council of State and Territorial Epidemiologists (CSTE) case definition for pertussis. PMID:29652945

  16. True versus Apparent Malaria Infection Prevalence: The Contribution of a Bayesian Approach

    PubMed Central

    Claes, Filip; Van Hong, Nguyen; Torres, Kathy; Mao, Sokny; Van den Eede, Peter; Thi Thinh, Ta; Gamboa, Dioni; Sochantha, Tho; Thang, Ngo Duc; Coosemans, Marc; Büscher, Philippe; D'Alessandro, Umberto; Berkvens, Dirk; Erhart, Annette

    2011-01-01

    Aims To present a new approach for estimating the “true prevalence” of malaria and apply it to datasets from Peru, Vietnam, and Cambodia. Methods Bayesian models were developed for estimating both the malaria prevalence using different diagnostic tests (microscopy, PCR & ELISA), without the need of a gold standard, and the tests' characteristics. Several sources of information, i.e. data, expert opinions and other sources of knowledge can be integrated into the model. This approach resulting in an optimal and harmonized estimate of malaria infection prevalence, with no conflict between the different sources of information, was tested on data from Peru, Vietnam and Cambodia. Results Malaria sero-prevalence was relatively low in all sites, with ELISA showing the highest estimates. The sensitivity of microscopy and ELISA were statistically lower in Vietnam than in the other sites. Similarly, the specificities of microscopy, ELISA and PCR were significantly lower in Vietnam than in the other sites. In Vietnam and Peru, microscopy was closer to the “true” estimate than the other 2 tests while as expected ELISA, with its lower specificity, usually overestimated the prevalence. Conclusions Bayesian methods are useful for analyzing prevalence results when no gold standard diagnostic test is available. Though some results are expected, e.g. PCR more sensitive than microscopy, a standardized and context-independent quantification of the diagnostic tests' characteristics (sensitivity and specificity) and the underlying malaria prevalence may be useful for comparing different sites. Indeed, the use of a single diagnostic technique could strongly bias the prevalence estimation. This limitation can be circumvented by using a Bayesian framework taking into account the imperfect characteristics of the currently available diagnostic tests. As discussed in the paper, this approach may further support global malaria burden estimation initiatives. PMID:21364745

  17. Programmatic Cost Evaluation of Nontargeted Opt-Out Rapid HIV Screening in the Emergency Department

    PubMed Central

    Haukoos, Jason S.; Campbell, Jonathan D.; Conroy, Amy A.; Hopkins, Emily; Bucossi, Meggan M.; Sasson, Comilla; Al-Tayyib, Alia A.; Thrun, Mark W.

    2013-01-01

    Background The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. Methods This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. Results During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%–0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%–4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Conclusions Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED. PMID:24391706

  18. A systematic review of the diagnostic performance of orthopedic physical examination tests of the hip

    PubMed Central

    2013-01-01

    Background Previous reviews of the diagnostic performances of physical tests of the hip in orthopedics have drawn limited conclusions because of the low to moderate quality of primary studies published in the literature. This systematic review aims to build on these reviews by assessing a broad range of hip pathologies, and employing a more selective approach to the inclusion of studies in order to accurately gauge diagnostic performance for the purposes of making recommendations for clinical practice and future research. It specifically identifies tests which demonstrate strong and moderate diagnostic performance. Methods A systematic search of Medline, Embase, Embase Classic and CINAHL was conducted to identify studies of hip tests. Our selection criteria included an analysis of internal and external validity. We reported diagnostic performance in terms of sensitivity, specificity, predictive values and likelihood ratios. Likelihood ratios were used to identify tests with strong and moderate diagnostic utility. Results Only a small proportion of tests reported in the literature have been assessed in methodologically valid primary studies. 16 studies were included in our review, producing 56 independent test-pathology combinations. Two tests demonstrated strong clinical utility, the patellar-pubic percussion test for excluding radiologically occult hip fractures (negative LR 0.05, 95% Confidence Interval [CI] 0.03-0.08) and the hip abduction sign for diagnosing sarcoglycanopathies in patients with known muscular dystrophies (positive LR 34.29, 95% CI 10.97-122.30). Fifteen tests demonstrated moderate diagnostic utility for diagnosing and/or excluding hip fractures, symptomatic osteoarthritis and loosening of components post-total hip arthroplasty. Conclusions We have identified a number of tests demonstrating strong and moderate diagnostic performance. These findings must be viewed with caution as there are concerns over the methodological quality of the primary studies from which we have extracted our data. Future studies should recruit larger, representative populations and allow for the construction of complete 2×2 contingency tables. PMID:23987589

  19. Diagnostic testing for Giardia infections.

    PubMed

    Heyworth, Martin F

    2014-03-01

    The traditional method for diagnosing Giardia infections involves microscopic examination of faecal specimens for Giardia cysts. This method is subjective and relies on observer experience. From the 1980s onwards, objective techniques have been developed for diagnosing Giardia infections, and are superseding diagnostic techniques reliant on microscopy. Detection of Giardia antigen(s) by immunoassay is the basis of commercially available diagnostic kits. Various nucleic acid amplification techniques (NAATs) can demonstrate DNA of Giardia intestinalis, and have the potential to become standard approaches for diagnosing Giardia infections. Of such techniques, methods involving either fluorescent microspheres (Luminex) or isothermal amplification of DNA (loop-mediated isothermal amplification; LAMP) are especially promising.

  20. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    PubMed

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  1. Expanding Access to Malaria Diagnosis through Retail Shops in Western Kenya: What Do Shop Workers Think?

    PubMed Central

    Koech, Beatrice; Obala, Andrew; O'Meara, Wendy Prudhomme

    2013-01-01

    Background. The common symptoms of malaria reduce the specificity of clinical diagnosis. Presumptive treatment is conventional but can lead to overdiagnosis of malaria, delay of appropriate treatment, overprescription of antimalarials, and drug resistance. Routine use of diagnostic tests can address many of these concerns. Though treatment is often procured from retailers, there is low availability of rapid diagnostic tests for malaria (MRDTs), a simple, inexpensive, and accurate diagnostic solution. We know little about the challenges to expanding access to diagnostics through these outlets. Methods. To understand the perceptions of the benefits and challenges to selling rapid diagnostic tests for malaria, we conducted focus group discussions with antimalarial retailers who serve the residents of the Webuye Health and Demographic Surveillance Site in western Kenya. Results. Medicine retailers perceived MRDTs to be beneficial to their customers and businesses but also included cost, fear of the tests, risks of self-treatment, and regulatory concerns among the challenges to using and selling MRDTs. Conclusion. MRDTs represent a viable approach to increase access to malaria diagnostic testing. Medicine retailers are eager for MRDTs to be made available to them. However, certain challenges remain to implementation in retail outlets and should be addressed in advance. PMID:23766923

  2. Rapid diagnostic tests compared with malaria microscopy for guiding outpatient treatment of febrile illness in Tanzania: randomised trial.

    PubMed

    Reyburn, Hugh; Mbakilwa, Hilda; Mwangi, Rose; Mwerinde, Ombeni; Olomi, Raimos; Drakeley, Chris; Whitty, Christopher J M

    2007-02-24

    To compare rapid diagnostic tests (RDTs) for malaria with routine microscopy in guiding treatment decisions for febrile patients. Randomised trial. Outpatient departments in northeast Tanzania at varying levels of malaria transmission. 2416 patients for whom a malaria test was requested. Staff received training on rapid diagnostic tests; patients sent for malaria tests were randomised to rapid diagnostic test or routine microscopy Proportion of patients with a negative test prescribed an antimalarial drug. Of 7589 outpatient consultations, 2425 (32%) had a malaria test requested. Of 1204 patients randomised to microscopy, 1030 (86%) tested negative for malaria; 523 (51%) of these were treated with an antimalarial drug. Of 1193 patients randomised to rapid diagnostic test, 1005 (84%) tested negative; 540 (54%) of these were treated for malaria (odds ratio 1.13, 95% confidence interval 0.95 to 1.34; P=0.18). Children aged under 5 with negative rapid diagnostic tests were more likely to be prescribed an antimalarial drug than were those with negative slides (P=0.003). Patients with a negative test by any method were more likely to be prescribed an antibiotic (odds ratio 6.42, 4.72 to 8.75; P<0.001). More than 90% of prescriptions for antimalarial drugs in low-moderate transmission settings were for patients for whom a test requested by a clinician was negative for malaria. Although many cases of malaria are missed outside the formal sector, within it malaria is massively over-diagnosed. This threatens the sustainability of deployment of artemisinin combination treatment, and treatable bacterial diseases are likely to be missed. Use of rapid diagnostic tests, with basic training for clinical staff, did not in itself lead to any reduction in over-treatment for malaria. Interventions to improve clinicians' management of febrile illness are essential but will not be easy. Clinical trials NCT00146796 [ClinicalTrials.gov].

  3. How patients navigate the diagnostic ecosystem in a fragmented health system: a qualitative study from India

    PubMed Central

    Yellapa, Vijayashree; Devadasan, Narayanan; Krumeich, Anja; Pant Pai, Nitika; Vadnais, Caroline; Pai, Madhukar; Engel, Nora

    2017-01-01

    ABSTRACT Background: Depending on a country’s diagnostic infrastructure, patients and providers play different roles in ensuring that correct and timely diagnosis is made. However, little is known about the work done by patients in accessing diagnostic services and completing the ‘test and treat’ loop. Objective: To address this knowledge gap, we traced the diagnostic journeys of patients with tuberculosis, diabetes, hypertension and typhoid, and examined the work they had to do to arrive at a diagnosis. Methods: This paper draws on a qualitative study, which included 78 semi-structured interviews and 13 focus group discussions with patients, public and private healthcare providers, community health workers, test manufacturers, laboratory technicians, program managers and policymakers. Data were collected between January and June 2013 in rural and urban Karnataka, South India, as part of a larger project on barriers to point-of-care testing. We reconstructed patient diagnostic processes retrospectively and analyzed emerging themes and patterns. Results: The journey to access diagnostic services requires a high level of involvement and immense work from patients and/or their caretakers. This process entails overcoming cost and distance, negotiating social relations, continuously making sense of their illness and diagnosis, producing and transporting samples, dealing with the social consequences of diagnosis, and returning results to the treating provider. The quality and content of interactions with providers were crucial for completion of test and treat loops. If the tasks became overwhelming, patients opted out, delayed being tested, switched providers and/or reverted to self-testing or self-treatment practices. Conclusion: Our study demonstrated how difficult it can be for patients to complete diagnostic journeys and how the health system works as far as diagnostics are concerned. If new point-of-care tests are to be implemented successfully, policymakers, program officers and test developers need to find ways to ease patient navigation through diagnostic services. PMID:28762894

  4. [Pilot tests using molecular diagnostic assay cervicovaginal infection during pregnancy].

    PubMed

    Beltrán-Montoya, J; Escudero-Gontes, S; Martínez-Huerta, N E; Ávila-Vergara, M A; Morales-Hernández, V; Canchola-Sotelo, C; Palacios-González, B; Vadillo-Ortega, F

    2016-08-01

    The prevalence of cervicovaginal infections during pregnancy has been associated with adverse perinatal outcomes however, the actual approach used for diagnosis is not effective. The aim of this study was to compare the diagnosis of vaginal infections in pregnant women using clinical, molecular diagnostic and traditional microbiological culture in a pilot study, to determine the prevalence and association with the development of preterm labor. We performed a nested cross-sectional study composed by 54 women in a cohort of pregnant women in Mexico City. Cervicovaginal infections were evaluated by clinical methods, microbiology culture and a commercially available molecular biology test. Prevalence of cervicovaginal infections during pregnancy was estimated between 28% and 50% according to methodologies. Considering the clinical diagnosis of preterm labor as the gold standard, all diagnostic tests were poor as predictors of preterm labor. Traditional approaches to establish the significance of cervicovaginal infection in pregnancy are exhausted, so be sought new ways to understand this complex relationship. Meanwhile it is recommended to continue to use traditional methods to identify infections during pregnancy in both knowledge of new methods aimed at understanding these relationships are sophisticated.

  5. System Related Interventions to Reduce Diagnostic Error: A Narrative Review

    PubMed Central

    Singh, Hardeep; Graber, Mark L.; Kissam, Stephanie M.; Sorensen, Asta V.; Lenfestey, Nancy F.; Tant, Elizabeth M.; Henriksen, Kerm; LaBresh, Kenneth A.

    2013-01-01

    Background Diagnostic errors (missed, delayed, or wrong diagnosis) have gained recent attention and are associated with significant preventable morbidity and mortality. We reviewed the recent literature to identify interventions that have been, or could be, implemented to address systems-related factors that contribute directly to diagnostic error. Methods We conducted a comprehensive search using multiple search strategies. We first identified candidate articles in English between 2000 and 2009 from a PubMed search that exclusively evaluated for articles related to diagnostic error or delay. We then sought additional papers from references in the initial dataset, searches of additional databases, and subject matter experts. Articles were included if they formally evaluated an intervention to prevent or reduce diagnostic error; however, we also included papers if interventions were suggested and not tested in order to inform the state-of-the science on the topic. We categorized interventions according to the step in the diagnostic process they targeted: patient-provider encounter, performance and interpretation of diagnostic tests, follow-up and tracking of diagnostic information, subspecialty and referral-related; and patient-specific. Results We identified 43 articles for full review, of which 6 reported tested interventions and 37 contained suggestions for possible interventions. Empirical studies, though somewhat positive, were non-experimental or quasi-experimental and included a small number of clinicians or health care sites. Outcome measures in general were underdeveloped and varied markedly between studies, depending on the setting or step in the diagnostic process involved. Conclusions Despite a number of suggested interventions in the literature, few empirical studies have tested interventions to reduce diagnostic error in the last decade. Advancing the science of diagnostic error prevention will require more robust study designs and rigorous definitions of diagnostic processes and outcomes to measure intervention effects. PMID:22129930

  6. Estimation of infection prevalence and sensitivity in a stratified two-stage sampling design employing highly specific diagnostic tests when there is no gold standard.

    PubMed

    Miller, Ezer; Huppert, Amit; Novikov, Ilya; Warburg, Alon; Hailu, Asrat; Abbasi, Ibrahim; Freedman, Laurence S

    2015-11-10

    In this work, we describe a two-stage sampling design to estimate the infection prevalence in a population. In the first stage, an imperfect diagnostic test was performed on a random sample of the population. In the second stage, a different imperfect test was performed in a stratified random sample of the first sample. To estimate infection prevalence, we assumed conditional independence between the diagnostic tests and develop method of moments estimators based on expectations of the proportions of people with positive and negative results on both tests that are functions of the tests' sensitivity, specificity, and the infection prevalence. A closed-form solution of the estimating equations was obtained assuming a specificity of 100% for both tests. We applied our method to estimate the infection prevalence of visceral leishmaniasis according to two quantitative polymerase chain reaction tests performed on blood samples taken from 4756 patients in northern Ethiopia. The sensitivities of the tests were also estimated, as well as the standard errors of all estimates, using a parametric bootstrap. We also examined the impact of departures from our assumptions of 100% specificity and conditional independence on the estimated prevalence. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Diagnostic Value of Cerebrospinal Fluid T-SPOT.TB for Tuberculousis Meningitis in China.

    PubMed

    Li, Xue Lian; Xie, Na; Wang, Song Wang; Wu, Qian Hong; Ma, Yan; Shu, Wei; Chen, Hong Mei; Zhang, Li Qun; Wu, Xiao Guang; Ma, Li Ping; Che, Nan Ying; Gao, Meng Qiu

    2017-09-01

    The aim of this study was to evaluate the diagnostic value of the cerebrospinal fluid (CSF) T-SPOT.TB test for the diagnosis of TB meningitis (TBM). A retrospective analysis of 96 patients with manifested meningitis was conducted; T-SPOT.TB test was performed for diagnosing TBM to determine the diagnostic sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). A receiver operating characteristic (ROC) curve was also drawn to assess the diagnostic accuracy. The sensitivity, specificity, PPV, and NPV of CSF T-SPOT.TB test were 97.8%, 78.0%, 80.3%, and 97.5%, respectively, for 52 patients (54.2%) of the 96 enrolled patients. The area under the curve (AUC) was 0.910, and the sensitivities of CSF T-SPOT.TB for patients with stages I, II, and III of TBM were 96.7%, 97.2%, and 98.9%, respectively. CSF T-SPOT.TB test is a rapid and accurate diagnostic method with higher sensitivity and specificity for diagnosing TBM. Copyright © 2017 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  8. Rapid extraction of virus-contaminated hemocytes from oysters

    USDA-ARS?s Scientific Manuscript database

    Rapid viral detection methods are necessary to employ diagnostic testing for viral contamination in shellfish to prevent and control foodborne illness. Current shellfish viral RNA extraction methods, which are time-consuming and not applicable for routine monitoring, require the testing of whole or ...

  9. Market Assessment of Tuberculosis Diagnostics in Brazil in 2012

    PubMed Central

    2014-01-01

    Background Improved diagnostics for the diagnosis of tuberculosis (TB) are urgently needed. However, test developers and investors require market size data to support new product development. This study assessed the served available market for TB diagnostics in Brazil in 2012 and the market segmentation in the public and private sectors. Methods Data were collected on test volumes done in the public and private sectors for the diagnosis of latent and active TB, drug susceptibility testing and treatment follow-up. Tests included were tuberculin skin tests, interferon-gamma releases assays, smear microscopy, solid and liquid cultures, nucleic acid amplification tests and phenotypic drug susceptibility tests. The data were collected by means of an electronic survey via the Brazilian State laboratories and from sales information provided by manufacturers. Test costs for the public sector were calculated using a components approach, while costs for the private sector were based on prices paid by patients. The overall market value (expenditure) for the entire country was calculated using the public sector test costs. Results During 2012, an estimated total of 2.4 million TB diagnostic tests were done in Brazil, resulting in an estimated overall market value of USD 17.2 million. The public sector accounted for 91% of the test volumes and 88% of the market value. Smear microscopy was the most commonly test (n = 1.3 million; 55% of total) at an estimated value of USD 3.7 million. Culture overall (n = 302,761) represented 13% of test volumes and 40% (USD 6.9 million) of the market value. On average, USD 208 was spent on TB diagnostics for every notified TB patient in Brazil, in 2012. Conclusion The TB diagnostics market value in Brazil in 2012 was over USD 17 million. These study results will help test developers to understand the current and potential market for replacement or add-on diagnostic technologies. PMID:25099237

  10. Bayesian evaluation of clinical diagnostic test characteristics of visual observations and remote monitoring to diagnose bovine respiratory disease in beef calves.

    PubMed

    White, Brad J; Goehl, Dan R; Amrine, David E; Booker, Calvin; Wildman, Brian; Perrett, Tye

    2016-04-01

    Accurate diagnosis of bovine respiratory disease (BRD) in beef cattle is a critical facet of therapeutic programs through promotion of prompt treatment of diseased calves in concert with judicious use of antimicrobials. Despite the known inaccuracies, visual observation (VO) of clinical signs is the conventional diagnostic modality for BRD diagnosis. Objective methods of remotely monitoring cattle wellness could improve diagnostic accuracy; however, little information exists describing the accuracy of this method compared to traditional techniques. The objective of this research is to employ Bayesian methodology to elicit diagnostic characteristics of conventional VO compared to remote early disease identification (REDI) to diagnose BRD. Data from previous literature on the accuracy of VO were combined with trial data consisting of direct comparison between VO and REDI for BRD in two populations. No true gold standard diagnostic test exists for BRD; therefore, estimates of diagnostic characteristics of each test were generated using Bayesian latent class analysis. Results indicate a 90.0% probability that the sensitivity of REDI (median 81.3%; 95% probability interval [PI]: 55.5, 95.8) was higher than VO sensitivity (64.5%; PI: 57.9, 70.8). The specificity of REDI (median 92.9%; PI: 88.2, 96.9) was also higher compared to VO (median 69.1%; PI: 66.3, 71.8). The differences in sensitivity and specificity resulted in REDI exhibiting higher positive and negative predictive values in both high (41.3%) and low (2.6%) prevalence situations. This research illustrates the potential of remote cattle monitoring to augment conventional methods of BRD diagnosis resulting in more accurate identification of diseased cattle. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Persistent digestive disorders in the tropics: causative infectious pathogens and reference diagnostic tests

    PubMed Central

    2013-01-01

    Background Persistent digestive disorders account for considerable disease burden in the tropics. Despite advances in understanding acute gastrointestinal infections, important issues concerning epidemiology, diagnosis, treatment and control of most persistent digestive symptomatologies remain to be elucidated. Helminths and intestinal protozoa are considered to play major roles, but the full extent of the aetiologic spectrum is still unclear. We provide an overview of pathogens causing digestive disorders in the tropics and evaluate available reference tests. Methods We searched the literature to identify pathogens that might give rise to persistent diarrhoea, chronic abdominal pain and/or blood in the stool. We reviewed existing laboratory diagnostic methods for each pathogen and stratified them by (i) microscopy; (ii) culture techniques; (iii) immunological tests; and (iv) molecular methods. Pathogen-specific reference tests providing highest diagnostic accuracy are described in greater detail. Results Over 30 pathogens may cause persistent digestive disorders. Bacteria, viruses and parasites are important aetiologic agents of acute and long-lasting symptomatologies. An integrated approach, consisting of stool culture, microscopy and/or specific immunological techniques for toxin, antigen and antibody detection, is required for accurate diagnosis of bacteria and parasites. Molecular techniques are essential for sensitive diagnosis of many viruses, bacteria and intestinal protozoa, and are increasingly utilised as adjuncts for helminth identification. Conclusions Diagnosis of the broad spectrum of intestinal pathogens is often cumbersome. There is a need for rapid diagnostic tests that are simple and affordable for resource-constrained settings, so that the management of patients suffering from persistent digestive disorders can be improved. PMID:23347408

  12. Estimating the Burden of Pneumococcal Pneumonia among Adults: A Systematic Review and Meta-Analysis of Diagnostic Techniques

    PubMed Central

    Said, Maria A.; Johnson, Hope L.; Nonyane, Bareng A. S.; Deloria-Knoll, Maria; O′Brien, Katherine L.

    2013-01-01

    Background Pneumococcal pneumonia causes significant morbidity and mortality among adults. Given limitations of diagnostic tests for non-bacteremic pneumococcal pneumonia, most studies report the incidence of bacteremic or invasive pneumococcal disease (IPD), and thus, grossly underestimate the pneumococcal pneumonia burden. We aimed to develop a conceptual and quantitative strategy to estimate the non-bacteremic disease burden among adults with community-acquired pneumonia (CAP) using systematic study methods and the availability of a urine antigen assay. Methods and Findings We performed a systematic literature review of studies providing information on the relative yield of various diagnostic assays (BinaxNOW® S. pneumoniae urine antigen test (UAT) with blood and/or sputum culture) in diagnosing pneumococcal pneumonia. We estimated the proportion of pneumococcal pneumonia that is bacteremic, the proportion of CAP attributable to pneumococcus, and the additional contribution of the Binax UAT beyond conventional diagnostic techniques, using random effects meta-analytic methods and bootstrapping. We included 35 studies in the analysis, predominantly from developed countries. The estimated proportion of pneumococcal pneumonia that is bacteremic was 24.8% (95% CI: 21.3%, 28.9%). The estimated proportion of CAP attributable to pneumococcus was 27.3% (95% CI: 23.9%, 31.1%). The Binax UAT diagnosed an additional 11.4% (95% CI: 9.6, 13.6%) of CAP beyond conventional techniques. We were limited by the fact that not all patients underwent all diagnostic tests and by the sensitivity and specificity of the diagnostic tests themselves. We address these resulting biases and provide a range of plausible values in order to estimate the burden of pneumococcal pneumonia among adults. Conclusions Estimating the adult burden of pneumococcal disease from bacteremic pneumococcal pneumonia data alone significantly underestimates the true burden of disease in adults. For every case of bacteremic pneumococcal pneumonia, we estimate that there are at least 3 additional cases of non-bacteremic pneumococcal pneumonia. PMID:23565216

  13. Diagnostic methods for CW laser damage testing

    NASA Astrophysics Data System (ADS)

    Stewart, Alan F.; Shah, Rashmi S.

    2004-06-01

    High performance optical coatings are an enabling technology for many applications - navigation systems, telecom, fusion, advanced measurement systems of many types as well as directed energy weapons. The results of recent testing of superior optical coatings conducted at high flux levels will be presented. The diagnostics used in this type of nondestructive testing and the analysis of the data demonstrates the evolution of test methodology. Comparison of performance data under load to the predictions of thermal and optical models shows excellent agreement. These tests serve to anchor the models and validate the performance of the materials and coatings.

  14. Comparing the Diagnostic Accuracy of Six Potential Screening Instruments for Bipolar Disorder in Youths Aged 5 to 17 Years.

    ERIC Educational Resources Information Center

    Youngstrom, Eric A.; Findling, Robert L.; Calabrese, Joseph R.; Gracious, Barbara L.; Demeter, Christine; DelPorto Bedoya, Denise; Price, Megan

    2004-01-01

    Objective: To compare the diagnostic efficiency of six index tests as predictors of juvenile bipolar disorder in two large outpatient samples, aged 5 to 10 and 11 to 17 years, gathered from 1997 to 2002. Method: DSM-IV diagnosis was based on a semistructured diagnostic interview (Schedule for Affective Disorders and Schizophrenia for School-Age…

  15. Linear combination methods to improve diagnostic/prognostic accuracy on future observations

    PubMed Central

    Kang, Le; Liu, Aiyi; Tian, Lili

    2014-01-01

    Multiple diagnostic tests or biomarkers can be combined to improve diagnostic accuracy. The problem of finding the optimal linear combinations of biomarkers to maximise the area under the receiver operating characteristic curve has been extensively addressed in the literature. The purpose of this article is threefold: (1) to provide an extensive review of the existing methods for biomarker combination; (2) to propose a new combination method, namely, the nonparametric stepwise approach; (3) to use leave-one-pair-out cross-validation method, instead of re-substitution method, which is overoptimistic and hence might lead to wrong conclusion, to empirically evaluate and compare the performance of different linear combination methods in yielding the largest area under receiver operating characteristic curve. A data set of Duchenne muscular dystrophy was analysed to illustrate the applications of the discussed combination methods. PMID:23592714

  16. Emerging commercial molecular tests for the diagnosis of bloodstream infection.

    PubMed

    Mwaigwisya, Solomon; Assiri, Rasha Assad M; O'Grady, Justin

    2015-05-01

    Bloodstream infection (BSI) by microorganisms can lead to sepsis. This condition has a high mortality rate, which rises significantly with delays in initiation of appropriate antimicrobial treatment. Current culture methods for diagnosing BSI have long turnaround times and poor clinical sensitivity. While clinicians wait for culture diagnosis, patients are treated empirically, which can result in inappropriate treatment, undesirable side effects and contribute to drug resistance development. Molecular diagnostics assays that target pathogen DNA can identify pathogens and resistance markers within hours. Early diagnosis improves antibiotic stewardship and is associated with favorable clinical outcomes. Nonetheless, limitations of current molecular diagnostic methods are substantial. This article reviews recent commercially available molecular methods that use pathogen DNA to diagnose BSI, either by testing positive blood cultures or directly testing patient blood. We critically assess these tests and their application in clinical microbiology. A view of future directions in BSI diagnosis is also provided.

  17. Auditory brainstem response (ABR) profiling tests as diagnostic support for schizophrenia and adult attention-deficit hyperactivity disorder (ADHD).

    PubMed

    Juselius Baghdassarian, Eva; Nilsson Markhed, Maria; Lindström, Eva; Nilsson, Björn M; Lewander, Tommy

    2018-06-01

    To evaluate the performances of two auditory brainstem response (ABR) profiling tests as potential biomarkers and diagnostic support for schizophrenia and adult attention-deficit hyperactivity disorder (ADHD), respectively, in an investigator-initiated blinded study design. Male and female patients with schizophrenia (n=26) and adult ADHD (n=24) meeting Diagnostic and Statistical Manual of Mental Disorders Fourth Edition (DSM IV) diagnostic criteria and healthy controls (n=58) comprised the analysis set (n=108) of the total number of study participants (n=119). Coded sets of randomized ABR recordings were analysed by an independent party blinded to clinical diagnoses before a joint code-breaking session. The ABR profiling test for schizophrenia identified schizophrenia patients versus controls with a sensitivity of 84.6% and a specificity of 93.1%. The ADHD test identified patients with adult ADHD versus controls with a sensitivity of 87.5% and a specificity of 91.4%. The ABR profiling tests discriminated schizophrenia and ADHD versus healthy controls with high sensitivity and specificity. The methods deserve to be further explored in larger clinical studies including a broad range of psychiatric disorders to determine their utility as potential diagnostic biomarkers.

  18. Is there a role for antibody testing in the diagnosis of invasive candidiasis?

    PubMed

    Quindós, Guillermo; Moragues, María Dolores; Pontón, José

    2004-03-01

    During the last decades, the use of antibody tests for the diagnosis of invasive mycoses has declined as a consequence of the general belief that they are insensitive and non-specific. However, there is a clear evidence that antibodies can be detected in highly immunodeficient patients (such as bone marrow transplant recipients), and that those antibodies are useful for the diagnosis. Antibody tests are currently in use as diagnostic tools for some primary mycoses, such as the endemic mycoses, aspergilloma, allergic bronchopulmonary aspergilosis and sporothrichosis. For invasive candidiasis, diagnostic methods must differentiate Candida colonization of mucous membranes or superficial infection from tissue invasion by this microorganism. Substantial progress has been made in diagnosis of invasive candidiasis with the development of a variety of methods for the detection of antibodies and antigens. However, no single test has found widespread clinical use and there is a consensus that diagnosis based on a single specimen lacks sensitivity. It is necessary to test sequential samples taken while the patient is at greatest risk for developing invasive candidiasis to optimize the diagnosis. Results obtained from a panel of diagnostic tests in association with clinical aspects will likely be the most useful strategy for early diagnosis and therapy.

  19. Potential point of care tests (POCTs) for maternal health in Peru, perspectives of pregnant women and their partners

    PubMed Central

    2014-01-01

    Background Globally, no qualitative studies have explored the perspectives of women and their partners about the integration of technology – and specifically diagnostic testing technologies – into antenatal care. The study objective was to describe the demand side for pregnancy-related diagnostic tests from the perspective of Peruvian consumers, including female and male community members, by engaging participants about their awareness of and care-seeking for pregnancy-related diagnostic tests and their preferred characteristics and testing conditions for pregnancy-related point-of-care diagnostic tests (POCTs). Methods Sixty-seven mothers and fathers of children under one from the peri-urban coast and the peri-urban and rural highlands and jungle of Peru participated in ten focus groups. Results Participants think that pregnancy-related diagnostic tests are important and they and their fellow community members are committed to ensuring that pregnant women receive the tests they need. Participants expressed clear demands for pregnancy-related POCTs, including important characteristics for the tests themselves (certification, rapid, reliable results) and for test implementation (well-trained, personable good communicators as test administrators at well-equipped, convenient testing sites). Participants emphasized the importance of short waiting times and explained that many people have some ability to pay for POCTs, particularly if they are innovative, rapid or multiplex. Conclusions Engaging future POCT users as consumers who are able to make key decisions about the development and implementation of pregnancy-related POCTs is valuable and informative. PMID:24433514

  20. Empirical likelihood-based confidence intervals for the sensitivity of a continuous-scale diagnostic test at a fixed level of specificity.

    PubMed

    Gengsheng Qin; Davis, Angela E; Jing, Bing-Yi

    2011-06-01

    For a continuous-scale diagnostic test, it is often of interest to find the range of the sensitivity of the test at the cut-off that yields a desired specificity. In this article, we first define a profile empirical likelihood ratio for the sensitivity of a continuous-scale diagnostic test and show that its limiting distribution is a scaled chi-square distribution. We then propose two new empirical likelihood-based confidence intervals for the sensitivity of the test at a fixed level of specificity by using the scaled chi-square distribution. Simulation studies are conducted to compare the finite sample performance of the newly proposed intervals with the existing intervals for the sensitivity in terms of coverage probability. A real example is used to illustrate the application of the recommended methods.

  1. Inverse probability weighting estimation of the volume under the ROC surface in the presence of verification bias.

    PubMed

    Zhang, Ying; Alonzo, Todd A

    2016-11-01

    In diagnostic medicine, the volume under the receiver operating characteristic (ROC) surface (VUS) is a commonly used index to quantify the ability of a continuous diagnostic test to discriminate between three disease states. In practice, verification of the true disease status may be performed only for a subset of subjects under study since the verification procedure is invasive, risky, or expensive. The selection for disease examination might depend on the results of the diagnostic test and other clinical characteristics of the patients, which in turn can cause bias in estimates of the VUS. This bias is referred to as verification bias. Existing verification bias correction in three-way ROC analysis focuses on ordinal tests. We propose verification bias-correction methods to construct ROC surface and estimate the VUS for a continuous diagnostic test, based on inverse probability weighting. By applying U-statistics theory, we develop asymptotic properties for the estimator. A Jackknife estimator of variance is also derived. Extensive simulation studies are performed to evaluate the performance of the new estimators in terms of bias correction and variance. The proposed methods are used to assess the ability of a biomarker to accurately identify stages of Alzheimer's disease. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. New method for detection of gastric cancer by hyperspectral imaging: a pilot study

    NASA Astrophysics Data System (ADS)

    Kiyotoki, Shu; Nishikawa, Jun; Okamoto, Takeshi; Hamabe, Kouichi; Saito, Mari; Goto, Atsushi; Fujita, Yusuke; Hamamoto, Yoshihiko; Takeuchi, Yusuke; Satori, Shin; Sakaida, Isao

    2013-02-01

    We developed a new, easy, and objective method to detect gastric cancer using hyperspectral imaging (HSI) technology combining spectroscopy and imaging A total of 16 gastroduodenal tumors removed by endoscopic resection or surgery from 14 patients at Yamaguchi University Hospital, Japan, were recorded using a hyperspectral camera (HSC) equipped with HSI technology Corrected spectral reflectance was obtained from 10 samples of normal mucosa and 10 samples of tumors for each case The 16 cases were divided into eight training cases (160 training samples) and eight test cases (160 test samples) We established a diagnostic algorithm with training samples and evaluated it with test samples Diagnostic capability of the algorithm for each tumor was validated, and enhancement of tumors by image processing using the HSC was evaluated The diagnostic algorithm used the 726-nm wavelength, with a cutoff point established from training samples The sensitivity, specificity, and accuracy rates of the algorithm's diagnostic capability in the test samples were 78.8% (63/80), 92.5% (74/80), and 85.6% (137/160), respectively Tumors in HSC images of 13 (81.3%) cases were well enhanced by image processing Differences in spectral reflectance between tumors and normal mucosa suggested that tumors can be clearly distinguished from background mucosa with HSI technology.

  3. Cancer diagnostics: The journey from histomorphology to molecular profiling.

    PubMed

    Ahmed, Atif A; Abedalthagafi, Malak

    2016-09-06

    Although histomorphology has made significant advances into the understanding of cancer etiology, classification and pathogenesis, it is sometimes complicated by morphologic ambiguities, and other shortcomings that necessitate the development of ancillary tests to complement its diagnostic value. A new approach to cancer patient management consists of targeting specific molecules or gene mutations in the cancer genome by inhibitory therapy. Molecular diagnostic tests and genomic profiling methods are increasingly being developed to identify tumor targeted molecular profile that is the basis of targeted therapy. Novel targeted therapy has revolutionized the treatment of gastrointestinal stromal tumor, renal cell carcinoma and other cancers that were previously difficult to treat with standard chemotherapy. In this review, we discuss the role of histomorphology in cancer diagnosis and management and the rising role of molecular profiling in targeted therapy. Molecular profiling in certain diagnostic and therapeutic difficulties may provide a practical and useful complement to histomorphology and opens new avenues for targeted therapy and alternative methods of cancer patient management.

  4. Diagnosis of Food Allergy.

    PubMed

    Gupta, Malika; Cox, Amanda; Nowak-Węgrzyn, Anna; Wang, Julie

    2018-02-01

    Food allergy diagnosis remains challenging. Most standard methods are unable to differentiate sensitization from clinical allergy. Recognizing food allergy is of utmost importance to prevent life-threatening reactions. On the other hand, faulty interpretation of tests leads to overdiagnosis and unnecessary food avoidances. Highly predictive models have been established for major food allergens based on skin prick testing and food-specific immunoglobulin E but are lacking for most other foods. Although many newer diagnostic techniques are improving the accuracy of food allergy diagnostics, an oral food challenge remains the only definitive method of confirming a food allergy. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Advances in the Diagnosis of Human Opisthorchiasis: Development of Opisthorchis viverrini Antigen Detection in Urine

    PubMed Central

    Duenngai, Kunyarat; Wangboon, Chompunoot; Sithithaworn, Jiraporn; Watwiengkam, Nattaya; Namwat, Nisana; Techasen, Anchalee; Loilome, Watcharin; Yongvanit, Puangrat; Loukas, Alex; Sithithaworn, Paiboon; Bethony, Jeffrey M.

    2015-01-01

    Background Many strategies to control opisthorchiasis have been employed in Thailand, but not in the other neighbouring countries. Specific control methods include mass drug administration (MDA) and health education to reduce raw fish consumption. These control efforts have greatly shifted the epidemiology of Opisthorchis viverrini (OV) infection over the last decade from presenting as densely concentrated "heavy" infections in single villages to widespread "light" OV infections distributed over wide geographical areas. Currently, the "gold standard" detection method for OV infection is formalin ethyl-acetate concentration technique (FECT), which has limited diagnostic sensitivity and diagnostic specificity for light OV infections, with OV eggs often confused with eggs of minute intestinal flukes (MIFs) in feces. In this study, we developed and evaluated the diagnostic performance of a monoclonal antibody-based enzyme-linked immunosorbent assay for the measurement of OV excretory-secretory (ES) antigens in urine (urine OV-ES assay) for the diagnosis of opisthorchiasis compared to the gold standard detection FECT method. Methodology We tested several methods for pre-treating urine samples prior to testing the diagnostic performance of the urine OV-ES assay. Using trichloroacetic acid (TCA) pre-treated urine, we compared detection and quantification of OV infection using the urine OV-ES assay versus FECT in OV-endemic areas in Northeastern Thailand. Receiver operating characteristic (ROC) curves were used to determine the diagnostic sensitivity and specificity of the urine OV-ES assay using TCA pre-treated urine, and to establish diagnostic positivity thresholds. The Positive Predictive Value as well as the likelihood of obtaining a positive test result (LR+) or a negative test result (LR-) were calculated for the established diagnostic positivity threshold. Diagnostic risks (Odds Ratios) were estimated using logistic regression. Results When urine samples were pre-treated with TCA prior to use in the urine OV-ES assay, the analytical sensitivity was significantly improved. Using TCA pre-treatment of urine, the urine OV-ES assay had a limit of detection (LoD) of 39 ng/ml compared to the LoD of 52 ng/mL reported for coprological antigen detection methods. Similarly, the urine OV-ES assay correlated significantly with intensity of OV infection as measured by FECT. The urine OV-ES assay was also able to detect 28 individuals as positive from the 63 (44.4%) individuals previously determined to be negative using FECT. The likelihood of a positive diagnosis of OV infection by urine OV-ES assay increased significantly with the intensity of OV infection as determined by FECT. With reference to FECT, the sensitivity and specificity of the urine OV-ES assay was 81% and 70%, respectively. Conclusion The detection of OV-infection by the urine OV-ES assay showed much greater diagnostic sensitivity and diagnostic specificity than the current "gold standard" FECT method for the detection and quantification of OV infection. Due to its ease-of-use, and noninvasive sample collection (urine), the urine OV-ES assay offers the potential to revolutionize the diagnosis of liver fluke infection and provide an effective tool for control and elimination of these tumorigenic parasites. PMID:26485024

  6. Variation in Results Release and Patient Portal Access to Diagnostic Test Results at an Academic Medical Center

    PubMed Central

    Krasowski, Matthew D.; Grieme, Caleb V.; Cassady, Brian; Dreyer, Nicholas R.; Wanat, Karolyn A.; Hightower, Maia; Nepple, Kenneth G.

    2017-01-01

    Background: Electronic health records (EHRs) are commonplace in industrialized countries. Many hospitals are granting their patients access to their medical information through online patient portals. In this report, we describe a retrospective analysis of patient access to diagnostic test results released through the patient portal (MyChart; Epic, Inc.) at a state academic medical center. Methods: We analyzed 6 months of data for anatomic pathology, clinical laboratory, and radiology test results to evaluate variations in results release (automated vs. manual) and subsequent patient access to the institutional patient portal. During this period, diagnostic test results were released for all patient encounters including inpatient units, outpatient clinics, and the emergency department. Results: Manual results release by providers before automated release time occurred most commonly in the outpatient setting. The highest rates of access of diagnostic test results occurred for outpatients (about 30% overall view rate), females (two times or more compared to males in nearly every age bracket), and 20–45-year-old. Access rates of diagnostic tests in the emergency department or inpatient units were <10% across all populations. Access of diagnostic test results was very low for 12–17-year-old, likely influenced by institutional policies limiting parental proxy access within this pediatric age range. Approximately 20% of outpatient laboratory results were viewed by patients within 8 h of release from the EHR to the patient portal and 10% within 2 h of release. Conclusions: Patient accessing of diagnostic test results were generally higher for females, outpatients, and 20–45-year-old. Approximately, 20% of outpatient results were viewed quickly by patients after release to the EHR. PMID:29226008

  7. Acid-fast Smear and Histopathology Results Provide Guidance for the Appropriate Use of Broad-Range Polymerase Chain Reaction and Sequencing for Mycobacteria.

    PubMed

    Miller, Kennon; Harrington, Susan M; Procop, Gary W

    2015-08-01

    New molecular diagnostic tests are attractive because of the potential they hold for improving diagnostics in microbiology. The value of these tests, which is often assumed, should be investigated to determine the best use of these potentially powerful tools. To investigate the usefulness of broad-range polymerase chain reaction (PCR), followed by sequencing, in mycobacterial infections. We reviewed the test performance of acid-fast bacilli (AFB) PCR and traditional diagnostic methods (histopathology, AFB smear, and culture). We assessed the diagnostic effect and cost of the unrestricted ordering of broad-range PCR for the detection and identification of mycobacteria in clinical specimens. The AFB PCR was less sensitive than culture and histopathology and was less specific than culture, AFB smear, and histopathology. During 18 months, $93 063 was spent on 183 patient specimens for broad-range PCR and DNA sequencing for mycobacteria to confirm one culture-proven Mycobacterium tuberculosis infection that was also known to be positive by AFB smear and histopathology. In this cohort, there was a false-negative AFB PCR for M tuberculosis and a false-positive AFB PCR for Mycobacterium lentiflavum . Testing of AFB smear-negative specimens from patients without an inflammatory response supportive of a mycobacterial infection is costly and has not been proven to improve patient care. Traditional diagnostics (histopathology, AFB smear, and culture) should remain the primary methods for the detection of mycobacteria in clinical specimens.

  8. A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows.

    PubMed

    Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F

    2016-08-01

    Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Programmatic cost evaluation of nontargeted opt-out rapid HIV screening in the emergency department.

    PubMed

    Haukoos, Jason S; Campbell, Jonathan D; Conroy, Amy A; Hopkins, Emily; Bucossi, Meggan M; Sasson, Comilla; Al-Tayyib, Alia A; Thrun, Mark W

    2013-01-01

    The Centers for Disease Control and Prevention recommends nontargeted opt-out HIV screening in healthcare settings. Cost effectiveness is critical when considering potential screening methods. Our goal was to compare programmatic costs of nontargeted opt-out rapid HIV screening with physician-directed diagnostic rapid HIV testing in an urban emergency department (ED) as part of the Denver ED HIV Opt-Out Trial. This was a prospective cohort study nested in a larger quasi-experiment. Over 16 months, nontargeted rapid HIV screening (intervention) and diagnostic rapid HIV testing (control) were alternated in 4-month time blocks. During the intervention phase, patients were offered HIV testing using an opt-out approach during registration; during the control phase, physicians used a diagnostic approach to offer HIV testing to patients. Each method was fully integrated into ED operations. Direct program costs were determined using the perspective of the ED. Time-motion methodology was used to estimate personnel activity costs. Costs per patient newly-diagnosed with HIV infection by intervention phase, and incremental cost effectiveness ratios were calculated. During the intervention phase, 28,043 eligible patients were included, 6,933 (25%) completed testing, and 15 (0.2%, 95% CI: 0.1%-0.4%) were newly-diagnosed with HIV infection. During the control phase, 29,925 eligible patients were included, 243 (0.8%) completed testing, and 4 (1.7%, 95% CI: 0.4%-4.2%) were newly-diagnosed with HIV infection. Total annualized costs for nontargeted screening were $148,997, whereas total annualized costs for diagnostic HIV testing were $31,355. The average costs per HIV diagnosis were $9,932 and $7,839, respectively. Nontargeted HIV screening identified 11 more HIV infections at an incremental cost of $10,693 per additional infection. Compared to diagnostic testing, nontargeted HIV screening was more costly but identified more HIV infections. More effective and less costly testing strategies may be required to improve the identification of patients with undiagnosed HIV infection in the ED.

  10. Willingness to pay for diagnostic technologies: a review of the contingent valuation literature.

    PubMed

    Lin, Pei-Jung; Cangelosi, Michael J; Lee, David W; Neumann, Peter J

    2013-01-01

    To understand how people value information from diagnostic technologies, we reviewed and analyzed published willingness-to-pay (WTP) studies on the topic. We searched PubMed for English-language articles related to WTP for diagnostic laboratory tests published from 1985 through 2011. We characterized methodological differences across studies, examined individual- and technology-level factors associated with WTP, and summarized median WTP values across different diagnostic tests. We identified 66 relevant WTP studies. Half focused on oncology, while others analyzed infectious diseases (n = 11, 16.1%) and obstetric or gynecological conditions (n = 8, 11.7%), among others. Most laboratory tests included in studies were biological samples/genetic testing (n = 44, 61.1%) or imaging tests (n = 23, 31.9%). Approximately one third of the analyses (n = 20, 30.3%) used discrete-choice questions to elicit WTP values. Higher income, education, disease severity, perceived disease risk, family history, and more accurate tests were in general associated with higher WTP values for diagnostic information. Of the 44 studies with median WTP values available, most reported a median WTP value below $100. The median WTP value for colon or colorectal cancer screening ranged from below $100 to over $1000. The contingent valuation literature in diagnostics has grown rapidly, and suggests that many respondents place considerable value on diagnostic information. There exists, however, great variation in studies with respect to the type of technologies and diseases assessed, respondent characteristics, and study methodology. The perceived value of diagnostic technologies is also influenced by the study design and elicitation methods. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  11. The role of neurologists and diagnostic tests in the management of distal symmetric polyneuropathy

    PubMed Central

    Callaghan, Brian C.; Kerber, Kevin A.; Lisabeth, Lynda L.; Morgenstern, Lewis B.; Longoria, Ruth; Rodgers, Ann; Longwell, Paxton; Feldman, Eva L.

    2014-01-01

    Importance Distal symmetric polyneuropathy (DSP) is a prevalent condition resulting in high costs from diagnostic testing. However, the role of neurologists and diagnostic tests on patient care is unknown. Objective To determine how often neurologists and diagnostic tests influence the diagnosis and management of DSP patients in a community setting. Design We utilized a validated case-capture method (ICD-9 screening technique with subsequent medical chart abstraction) to identify patients with a new DSP diagnosis (retrospective cohort). Using a structured data abstraction process, diagnostic testing, diagnoses rendered (before and after testing), and subsequent management were recorded. Setting Community neurologist’s outpatient offices in Corpus Christi, Texas. Participants Patients meeting the Toronto consensus criteria for probable DSP. Main Outcome Measure Changes in etiology and management after diagnostic testing by neurologists. Results Between 1/1/2010–3/31/2011, we identified 458 DSP patients followed for mean (SD) 435.3 (44.1) days. Neurologists identified a cause of DSP in 63.5% of cases prior to their diagnostic testing. Seventy-one patients (15.5%) had a new DSP cause discovered after testing by neurologists. The most common new diagnoses were pre-diabetes (N=28), B12 deficiency (N=20), diabetes (N=8), and thyroid disease (N=8). Management changes were common (63.1%), usually related to neuropathic pain management (77.5%). Disease modifying management changes occurred in 24.7% with diabetes management (N=45), starting vitamins (N=39), advising diet/exercise (N=33), and adjusting thyroid medications (N=10) the most common. Electrodiagnostic testing and MRIs of the neuroaxis rarely led to management changes. Conclusions and Relevance Neurologists diagnosed the cause of DSP in almost two-thirds of patients prior to their diagnostic testing. Inexpensive blood tests for diabetes, thyroid dysfunction, and B12 deficiency, allowed neurologists to identify a new etiology in 15.5% of patients. In contrast, expensive electrodiagnostic tests and MRIs rarely changed patient care. Neurologists also frequently made pain medication changes utilizing best evidence medications. PMID:25048157

  12. Clinical review: Current state and future perspectives in the diagnosis of diabetes insipidus: a clinical review.

    PubMed

    Fenske, Wiebke; Allolio, Bruno

    2012-10-01

    The differential diagnosis of diabetes insipidus (DI) is often challenging but essential, because treatment may vary substantially. This article analyzes the database and performance of currently used differential diagnostic tests for DI and discusses future perspectives for diagnostic improvement. A review of electronic and print data comprising original and review articles retrieved from the PubMed or Cochrane Library database up to January 2012 was conducted. The search term "polyuria polydipsia syndrome" was cross-referenced with underlying forms of disease and associated clinical, diagnostic, and therapeutic MeSH terms. In addition, references from review articles and textbook chapters were screened for papers containing original data. Search results were narrowed to articles containing primary data with a description of criteria for the differential diagnosis of DI. Fifteen articles on differential diagnosis of DI were identified, mainly consisting of small series of patients, and mostly covering only part of the differential diagnostic spectrum of DI. Test protocols differed, and prospective validation of diagnostic criteria was consistently missing. Inconsistent data were reported on the diagnostic superiority of direct plasma arginine vasopressin determination over the indirect water deprivation test. Both test methods revealed limitations, especially in the differentiation of disorders with a milder phenotype. The available data demonstrate limitations of current biochemical tests for the differential diagnosis of DI, potentially leading to incorrect diagnosis and treatment. The newly available assay for copeptin, the C terminus of the vasopressin precursor, holds promise for a higher diagnostic specificity and simplification of the differential diagnostic protocol in DI.

  13. Surveillance of intestinal schistosomiasis during control: a comparison of four diagnostic tests across five Ugandan primary schools in the Lake Albert region.

    PubMed

    Al-Shehri, Hajri; Koukounari, Artemis; Stanton, Michelle C; Adriko, Moses; Arinaitwe, Moses; Atuhaire, Aaron; Kabatereine, Narcis B; Stothard, J Russell

    2018-03-21

    Programmatic surveillance of intestinal schistosomiasis during control can typically use four diagnostic tests, either singularly or in combination, but these have yet to be cross-compared directly. Our study assembled a complete diagnostic dataset, inclusive of infection intensities, from 258 children from five Ugandan primary schools. The schools were purposely selected as typical of the endemic landscape near Lake Albert and reflective of high- and low-transmission settings. Overall prevalence was: 44.1% (95% CI 38.0-50.2) by microscopy of duplicate Kato-Katz smears from two consecutive stools, 56.9% (95% CI 50.8-63.0) by urine-circulating cathodic antigen (CCA) dipstick, 67.4% (95% CI 61.6-73.1) by DNA-TaqMan® and 75.1% (95% CI 69.8-80.4) by soluble egg antigen enzyme-linked immunosorbent assay (SEA-ELISA). A cross-comparison of diagnostic sensitivities, specificities, positive and negative predictive values was undertaken, inclusive of a latent class analysis (LCA) with a LCA-model estimate of prevalence by each school. The latter ranged from 9.6% to 100.0%, and prevalence by school for each diagnostic test followed a static ascending order or monotonic series of Kato-Katz, urine-CCA dipstick, DNA-TaqMan® and SEA-ELISA. We confirm that Kato-Katz remains a satisfactory diagnostic standalone in high-transmission settings but in low-transmission settings should be augmented or replaced by urine-CCA dipsticks. DNA-TaqMan® appears suitable in both endemic settings though is only implementable if resources permit. In low-transmission settings, SEA-ELISA remains the method of choice to evidence an absence infection. We discuss the pros and cons of each method concluding that future surveillance of intestinal schistosomiasis would benefit from a flexible, context-specific approach both in choice and application of each diagnostic method, rather than a single one-size fits all approach.

  14. Predictive inference for best linear combination of biomarkers subject to limits of detection.

    PubMed

    Coolen-Maturi, Tahani

    2017-08-15

    Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine, machine learning and credit scoring. The receiver operating characteristic (ROC) curve is a useful tool to assess the ability of a diagnostic test to discriminate between two classes or groups. In practice, multiple diagnostic tests or biomarkers are combined to improve diagnostic accuracy. Often, biomarker measurements are undetectable either below or above the so-called limits of detection (LoD). In this paper, nonparametric predictive inference (NPI) for best linear combination of two or more biomarkers subject to limits of detection is presented. NPI is a frequentist statistical method that is explicitly aimed at using few modelling assumptions, enabled through the use of lower and upper probabilities to quantify uncertainty. The NPI lower and upper bounds for the ROC curve subject to limits of detection are derived, where the objective function to maximize is the area under the ROC curve. In addition, the paper discusses the effect of restriction on the linear combination's coefficients on the analysis. Examples are provided to illustrate the proposed method. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Rapid phenotypic antimicrobial susceptibility testing using nanoliter arrays.

    PubMed

    Avesar, Jonathan; Rosenfeld, Dekel; Truman-Rosentsvit, Marianna; Ben-Arye, Tom; Geffen, Yuval; Bercovici, Moran; Levenberg, Shulamit

    2017-07-18

    Antibiotic resistance is a major global health concern that requires action across all sectors of society. In particular, to allow conservative and effective use of antibiotics clinical settings require better diagnostic tools that provide rapid determination of antimicrobial susceptibility. We present a method for rapid and scalable antimicrobial susceptibility testing using stationary nanoliter droplet arrays that is capable of delivering results in approximately half the time of conventional methods, allowing its results to be used the same working day. In addition, we present an algorithm for automated data analysis and a multiplexing system promoting practicality and translatability for clinical settings. We test the efficacy of our approach on numerous clinical isolates and demonstrate a 2-d reduction in diagnostic time when testing bacteria isolated directly from urine samples.

  16. Diagnostics of Technical Condition of Gear Units of Belt Conveyors for the Aggregate of Methods of Nondestructive Testing

    NASA Astrophysics Data System (ADS)

    Kuzin, Evgeny G.; Gerike, Boris L.; Drozdenko, Yuriy V.; Lupiy, Michael G.; Grigoryeva, Natalya V.

    2017-10-01

    The article reviews the issues of complex use of methods of technical diagnostics of gearboxes for belt conveyors, with the aim of creating an effective system of maintenance. The article is showing the results of the evaluation of the technical condition of the drives of belt conveyors based on vibration monitoring and thermal parameters, and analysis of lubricating oil.

  17. [Microbiological point of care tests].

    PubMed

    Book, Malte; Lehmann, Lutz Eric; Zhang, Xianghong; Stüber, Frank

    2010-11-01

    It is well known that the early initiation of a specific antiinfective therapy is crucial to reduce the mortality in severe infection. Procedures culturing pathogens are the diagnostic gold standard in such diseases. However, these methods yield results earliest between 24 to 48 hours. Therefore, severe infections such as sepsis need to be treated with an empirical antimicrobial therapy, which is ineffective in an unknown fraction of these patients. Today's microbiological point of care tests are pathogen specific and therefore not appropriate for an infection with a variety of possible pathogens. Molecular nucleic acid diagnostics such as polymerase chain reaction (PCR) allow the identification of pathogens and resistances. These methods are used routinely to speed up the analysis of positive blood cultures. The newest PCR based system allows the identification of the 25 most frequent sepsis pathogens by PCR in parallel without previous culture in less than 6 hours. Thereby, these systems might shorten the time of possibly insufficient antiinfective therapy. However, these extensive tools are not suitable as point of care diagnostics. Miniaturization and automating of the nucleic acid based method is pending, as well as an increase of detectable pathogens and resistance genes by these methods. It is assumed that molecular PCR techniques will have an increasing impact on microbiological diagnostics in the future. © Georg Thieme Verlag Stuttgart · New York.

  18. A simple sandwich ELISA (WELYSSA) for the detection of lyssavirus nucleocapsid in rabies suspected specimens using mouse monoclonal antibodies.

    PubMed

    Xu, Gelin; Weber, Patrick; Hu, Qiaoling; Xue, Honggang; Audry, Laurent; Li, Chengping; Wu, Jie; Bourhy, Herve

    2007-10-01

    Monoclonal antibody (MAb)-based capture enzyme-linked immunosorbent assays (ELISA) were developed for the diagnosis of rabies-suspect specimens. A combination of four mouse monoclonal antibodies directed against the rabies virus nucleocapsid was selected and used for the detection. The test was optimized and standardized so that maximum concordance could be maintained with the standard procedures of rabies diagnosis recommended by the WHO expert committee. Using prototype viruses from the different genotypes of lyssavirus and from various geographic origins and phylogenetic lineages, this paper presents a reliable, rapid and transferable diagnostic method, named WELYSSA that readily permits the detection of lyssaviruses belonging to the 7 genotypes of lyssavirus circulating in Europe, Africa, Asia and Oceania. The threshold of detection of lyssavirus nucleocapsids is low (0.8 ng/ml). With a panel of 1030 specimens received for rabies diagnostic testing, this test was found to be highly specific (0.999) and sensitive (0.970) when compared to other recommended rabies diagnostic methods.

  19. Rolling bearing fault diagnosis based on information fusion using Dempster-Shafer evidence theory

    NASA Astrophysics Data System (ADS)

    Pei, Di; Yue, Jianhai; Jiao, Jing

    2017-10-01

    This paper presents a fault diagnosis method for rolling bearing based on information fusion. Acceleration sensors are arranged at different position to get bearing vibration data as diagnostic evidence. The Dempster-Shafer (D-S) evidence theory is used to fuse multi-sensor data to improve diagnostic accuracy. The efficiency of the proposed method is demonstrated by the high speed train transmission test bench. The results of experiment show that the proposed method in this paper improves the rolling bearing fault diagnosis accuracy compared with traditional signal analysis methods.

  20. Analysis of Added Value of Subscores with Respect to Classification

    ERIC Educational Resources Information Center

    Sinharay, Sandip

    2014-01-01

    Brennan noted that users of test scores often want (indeed, demand) that subscores be reported, along with total test scores, for diagnostic purposes. Haberman suggested a method based on classical test theory (CTT) to determine if subscores have added value over the total score. One way to interpret the method is that a subscore has added value…

  1. Fetal Intelligent Navigation Echocardiography (FINE): a novel method for rapid, simple, and automatic examination of the fetal heart.

    PubMed

    Yeo, Lami; Romero, Roberto

    2013-09-01

    To describe a novel method (Fetal Intelligent Navigation Echocardiography (FINE)) for visualization of standard fetal echocardiography views from volume datasets obtained with spatiotemporal image correlation (STIC) and application of 'intelligent navigation' technology. We developed a method to: 1) demonstrate nine cardiac diagnostic planes; and 2) spontaneously navigate the anatomy surrounding each of the nine cardiac diagnostic planes (Virtual Intelligent Sonographer Assistance (VIS-Assistance®)). The method consists of marking seven anatomical structures of the fetal heart. The following echocardiography views are then automatically generated: 1) four chamber; 2) five chamber; 3) left ventricular outflow tract; 4) short-axis view of great vessels/right ventricular outflow tract; 5) three vessels and trachea; 6) abdomen/stomach; 7) ductal arch; 8) aortic arch; and 9) superior and inferior vena cava. The FINE method was tested in a separate set of 50 STIC volumes of normal hearts (18.6-37.2 weeks of gestation), and visualization rates for fetal echocardiography views using diagnostic planes and/or VIS-Assistance® were calculated. To examine the feasibility of identifying abnormal cardiac anatomy, we tested the method in four cases with proven congenital heart defects (coarctation of aorta, tetralogy of Fallot, transposition of great vessels and pulmonary atresia with intact ventricular septum). In normal cases, the FINE method was able to generate nine fetal echocardiography views using: 1) diagnostic planes in 78-100% of cases; 2) VIS-Assistance® in 98-100% of cases; and 3) a combination of diagnostic planes and/or VIS-Assistance® in 98-100% of cases. In all four abnormal cases, the FINE method demonstrated evidence of abnormal fetal cardiac anatomy. The FINE method can be used to visualize nine standard fetal echocardiography views in normal hearts by applying 'intelligent navigation' technology to STIC volume datasets. This method can simplify examination of the fetal heart and reduce operator dependency. The observation of abnormal echocardiography views in the diagnostic planes and/or VIS-Assistance® should raise the index of suspicion for congenital heart disease. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  2. Polish Adult Reading Test (PART) - construction of Polish test for estimating the level of premorbid intelligence in schizophrenia.

    PubMed

    Karakuła-Juchnowicz, Hanna; Stecka, Mariola

    2017-08-29

    In view of unavailability in Poland of the standardized methods to measure PIQ, the aim of the work was to develop a Polish test to assess the premorbid level of intelligence - PART(Polish AdultReading Test) and to measureits psychometric properties, such as validity, reliability as well as standardization in the group of schizophrenia patients. The principles of PART construction were based on the idea of popular worldwide National Adult Reading Test by Hazel Nelson. The research comprised a group of 122 subjects (65 schizophrenia patients and 57 healthy people), aged 18-60 years, matched for age and gender. PART appears to be a method with high internal consistency and reliability measured by test-retest, inter-rater reliability, and the method with acceptable diagnostic and prognostic validity. The standardized procedures of PART have been investigated and described. Considering the psychometric values of PART and a short time of its performance, the test may be a useful diagnostic instrument in the assessment of premorbid level of intelligence in a group of schizophrenic patients.

  3. Perendoscopic gastric pH determination. Simple method for increasing accuracy in diagnosing chronic atrophic gastritis.

    PubMed

    Farinati, F; Cardin, F; Di Mario, F; Sava, G A; Piccoli, A; Costa, F; Penon, G; Naccarato, R

    1987-08-01

    The endoscopic diagnosis of chronic atrophic gastritis is often underestimated, and most of the procedures adopted to increase diagnostic accuracy are time consuming and complex. In this study, we evaluated the usefulness of the determination of gastric juice pH by means of litmus paper. Values obtained by this method correlate well with gastric acid secretory capacity as measured by gastric acid analysis (r = -0.64, p less than 0.001) and are not affected by the presence of bile. Gastric juice pH determination increases sensitivity and other diagnostic parameters such as performance index (Youden J test), positive predictive value, and post-test probability difference by 50%. Furthermore, the negative predictive value is very high, the probability of missing a patient with chronic atrophic gastritis with this simple method being 2% for fundic and 15% for antral atrophic change. We conclude that gastric juice pH determination, which substantially increases diagnostic accuracy and is very simple to perform, should be routinely adopted.

  4. An SSP-PCR method for the rapid detection of disease-associated alleles HLA-A*29 and HLA-B*51.

    PubMed

    Amstutz, U; Schaerer, D; Andrey, G; Wirthmueller, U; Largiadèr, C R

    2018-05-15

    HLA-A*29 and HLA-B*51 are associated with birdshot uveitis and Behçet's disease, respectively, and are used as a diagnostic criterion in patients with suspected disease, requiring their detection in diagnostic laboratories. While commercial tests for individual HLA alleles are available for other disease-associated HLA variants, no similar allele-specific assays are available for HLA-A*29 and -B*51. Here, we report SSP-PCR methods for the detection of HLA-A*29 and -B*51 using a single PCR reaction per allele. The assays were tested in 30 and 32 previously HLA-typed samples, respectively, representing >97% of HLA-A alleles and >93% of HLA-B alleles in a European population. A concordance of 100% was observed with previous typing results, validating these methods for use in a diagnostic or research context. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Update on diagnostic value of breath test in gastrointestinal and liver diseases

    PubMed Central

    Siddiqui, Imran; Ahmed, Sibtain; Abid, Shahab

    2016-01-01

    In the field of gastroenterology, breath tests (BTs) are used intermittently as diagnostic tools that allow indirect, non-invasive and relatively less cumbersome evaluation of several disorders by simply quantifying the appearance in exhaled breath of a metabolite of a specific substrate administered. The aim of this review is to have an insight into the principles, methods of analysis and performance parameters of various hydrogen, methane and carbon BTs which are available for diagnosing gastrointestinal disorders such as Helicobacter pylori infection, small intestinal bacterial overgrowth, and carbohydrate malabsorption. Evaluation of gastric emptying is routinely performed by scintigraphy which is however, difficult to perform and not suitable for children and pregnant women, this review has abridged the 13C-octanoic acid test in comparison to scintigraphy and has emphasized on its working protocol and challenges. A new development such as electronic nose test is also highlighted. Moreover we have also explored the limitations and constraints restraining the wide use of these BT. We conclude that breath testing has an enormous potential to be used as a diagnostic modality. In addition it offers distinct advantages over the traditional invasive methods commonly employed. PMID:27574563

  6. Rocket Engine Plume Diagnostics at Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Tejwani, Gopal D.; Langford, Lester A.; VanDyke, David B.; McVay, Gregory P.; Thurman, Charles C.

    2003-01-01

    The Stennis Space Center has been at the forefront of development and application of exhaust plume spectroscopy to rocket engine health monitoring since 1989. Various spectroscopic techniques, such as emission, absorption, FTIR, LIF, and CARS, have been considered for application at the engine test stands. By far the most successful technology h a been exhaust plume emission spectroscopy. In particular, its application to the Space Shuttle Main Engine (SSME) ground test health monitoring has been invaluable in various engine testing and development activities at SSC since 1989. On several occasions, plume diagnostic methods have successfully detected a problem with one or more components of an engine long before any other sensor indicated a problem. More often, they provide corroboration for a failure mode, if any occurred during an engine test. This paper gives a brief overview of our instrumentation and computational systems for rocket engine plume diagnostics at SSC. Some examples of successful application of exhaust plume spectroscopy (emission as well as absorption) to the SSME testing are presented. Our on-going plume diagnostics technology development projects and future requirements are discussed.

  7. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    PubMed

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  8. Diagnosis of Brucellosis in Livestock and Wildlife

    PubMed Central

    Godfroid, Jacques; Nielsen, Klaus; Saegerman, Claude

    2010-01-01

    Aim To describe and discuss the merits of various direct and indirect methods applied in vitro (mainly on blood or milk) or in vivo (allergic test) for the diagnosis of brucellosis in animals. Methods The recent literature on brucellosis diagnostic tests was reviewed. These diagnostic tests are applied with different goals, such as national screening, confirmatory diagnosis, certification, and international trade. The validation of such diagnostic tests is still an issue, particularly in wildlife. The choice of the testing strategy depends on the prevailing brucellosis epidemiological situation and the goal of testing. Results Measuring the kinetics of antibody production after Brucella spp. infection is essential for analyzing serological results correctly and may help to predict abortion. Indirect ELISAs help to discriminate 1) between false positive serological reactions and true brucellosis and 2) between vaccination and infection. Biotyping of Brucella spp. provides valuable epidemiological information that allows tracing an infection back to the sources in instances where several biotypes of a given Brucella species are circulating. Polymerase chain reaction and new molecular methods are likely to be used as routine typing and fingerprinting methods in the coming years. Conclusion The diagnosis of brucellosis in livestock and wildlife is complex and serological results need to be carefully analyzed. The B. abortus S19 and B. melitensis Rev. 1 vaccines are the cornerstones of control programs in cattle and small ruminants, respectively. There is no vaccine available for pigs or for wildlife. In the absence of a human brucellosis vaccine, prevention of human brucellosis depends on the control of the disease in animals. PMID:20718082

  9. Rapid detection of D-Dimers with mLabs® whole blood method for venous thromboembolism exclusion. Comparison with Vidas® D-Dimers assay.

    PubMed

    Gerotziafas, Grigoris T; Ray, Patrick; Gkalea, Vasiliki; Benzarti, Ahlem; Khaterchi, Amir; Cast, Claire; Pernet, Julie; Lefkou, Eleftheria; Elalamy, Ismail

    2016-12-01

    Easy to use point of care assays for D-Dimers measurement in whole blood from patients with clinical suspicion of venous thromboembolism (VTE) will facilitate the diagnostic strategy in the Emergency Department (ED) setting. We prospectively evaluated the diagnostic performance of the point-of-care mLabs® Whole Blood D-Dimers test and we compared it with the Vidas® D-Dimers assay. As part of the diagnostic algorithm applied in patients with clinical suspicion of VTE, the VIDAS® D-Dimers Test was prescribed by the emergency physician in charge. The mLabs® Whole Blood D-Dimers Test was used on the same samples. All patients had undergone exploration with the recommended imaging techniques for VTE diagnosis. Both assays were performed, on 99 emergency patients (mean age was 65 years) with clinical suspicion of VTE. In 3% of patients, VTE was documented with a reference imaging technique. The Bland and Altman test showed significant agreement between the two methods. Both assays showed equal sensitivity and negative predictive value for VTE. The mLabs whole blood assay is a promising point of care method for measurement of D-Dimers and exclusion of VTE diagnosis in the emergency setting which should be validated in a larger prospective study.

  10. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    PubMed

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .

  11. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-01-01

    Introduction With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. Materials and methods In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Results Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Conclusions Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia. PMID:27812306

  12. Diagnostic Yield of Laboratory Methods and Value of Viral Genotyping during an Outbreak of Mumps in a Partially Vaccinated Population in British Columbia, Canada.

    PubMed

    Nunn, Alexandra; Masud, Shazia; Krajden, Mel; Naus, Monika; Jassem, Agatha N

    2018-05-01

    Mumps remains endemic in North America despite routine use of the measles, mumps, and rubella (MMR) vaccine. In 2016, an outbreak of mumps in British Columbia, Canada, provided an opportunity to determine the diagnostic utility of laboratory testing methods. Specimens from patients with clinical mumps were tested for infection using a commercial enzyme-linked immunosorbent assay (ELISA) for antibody detection and an in-house reverse transcriptase PCR (RT-PCR) targeting viral fusion and small hydrophobic (SH) genes. Viral genotyping was performed by SH gene sequencing. Laboratory data was linked with epidemiologic case data. Of the 139 confirmed cases, 94 (68%) had reported or documented history of MMR vaccination. Specimens were typically collected 1 day (for buccal and IgM tests) or 2 days (for urine tests) after symptom onset. Most confirmed cases (69%) were confirmed by buccal swab RT-PCR. Among cases tested by multiple methods, the percent positivity for buccal swab RT-PCR was 90% (96/107) compared to 43% (30/69) for both IgM ELISA and urine RT-PCR. Mumps IgM detection was higher in confirmed cases with no history of vaccination than in those with history (64% versus 34%, P = 0.02). The outbreak strain was identified as genotype G related to MuVi/Sheffield.GBR/1.05 but with conserved variations in five nucleotides within the SH gene that allowed linkage of geographically distinct cases. In conclusion, RT-PCR of buccal specimens had the highest diagnostic yield during a mumps outbreak in a partially vaccinated population. To optimize mumps diagnostic potential, clinicians should collect specimens depending on when the patient presents for care and their immunization history. © Crown copyright 2018.

  13. Electrophysiology of Cranial Nerve Testing: Trigeminal and Facial Nerves.

    PubMed

    Muzyka, Iryna M; Estephan, Bachir

    2018-01-01

    The clinical examination of the trigeminal and facial nerves provides significant diagnostic value, especially in the localization of lesions in disorders affecting the central and/or peripheral nervous system. The electrodiagnostic evaluation of these nerves and their pathways adds further accuracy and reliability to the diagnostic investigation and the localization process, especially when different testing methods are combined based on the clinical presentation and the electrophysiological findings. The diagnostic uniqueness of the trigeminal and facial nerves is their connectivity and their coparticipation in reflexes commonly used in clinical practice, namely the blink and corneal reflexes. The other reflexes used in the diagnostic process and lesion localization are very nerve specific and add more diagnostic yield to the workup of certain disorders of the nervous system. This article provides a review of commonly used electrodiagnostic studies and techniques in the evaluation and lesion localization of cranial nerves V and VII.

  14. The impact of patents on the development of genome-based clinical diagnostics: an analysis of case studies

    PubMed Central

    Pierce, Brandon L.; Carlson, Christopher S.; Kuszler, Patricia C.; Stanford, Janet L.; Austin, Melissa A.

    2010-01-01

    Purpose Fragmented ownership of diagnostic gene patents has the potential to create an ‘anticommons’ in the area of genomic diagnostics, making it difficult and expensive to assemble the patent rights necessary to develop a panel of genetic tests. The objectives of this study were to identify U.S. patents that protect existing panels of genetic tests, describe how (or if) test providers acquired rights to these patents, and determine if fragmented patent ownership has inhibited the commercialization of these panels. Methods As case studies, we selected four clinical applications of genetic testing (cystic fibrosis, maturity-onset diabetes of the young, long QT syndrome, and hereditary breast cancer) that utilize tests protected by ≥3 U.S. patents. We summarized publically available information on relevant patents, test providers, licenses, and litigation. Results For each case study, all tests of major genes/mutations were patented, and at least one party held the collective rights to conduct all relevant tests, often as a result of licensing agreements. Conclusions We did not find evidence that fragmentation of patent rights has inhibited commercialization of genetic testing services. However, as knowledge of genetic susceptibility increases, it will be important to consider the potential consequences of fragmented ownership of diagnostic gene patents. PMID:19367193

  15. A real-time PCR diagnostic method for detection of Naegleria fowleri.

    PubMed

    Madarová, Lucia; Trnková, Katarína; Feiková, Sona; Klement, Cyril; Obernauerová, Margita

    2010-09-01

    Naegleria fowleri is a free-living amoeba that can cause primary amoebic meningoencephalitis (PAM). While, traditional methods for diagnosing PAM still rely on culture, more current laboratory diagnoses exist based on conventional PCR methods; however, only a few real-time PCR processes have been described as yet. Here, we describe a real-time PCR-based diagnostic method using hybridization fluorescent labelled probes, with a LightCycler instrument and accompanying software (Roche), targeting the Naegleria fowleriMp2Cl5 gene sequence. Using this method, no cross reactivity with other tested epidemiologically relevant prokaryotic and eukaryotic organisms was found. The reaction detection limit was 1 copy of the Mp2Cl5 DNA sequence. This assay could become useful in the rapid laboratory diagnostic assessment of the presence or absence of Naegleria fowleri. Copyright 2009 Elsevier Inc. All rights reserved.

  16. Phosphorus blood test

    MedlinePlus

    ... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:878-880. Klemm ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 15. Kliegman RM, ...

  17. Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, James H.

    2005-01-01

    An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.

  18. Accuracy of clinical tests in the diagnosis of anterior cruciate ligament injury: a systematic review

    PubMed Central

    2014-01-01

    Background Numerous clinical tests are used in the diagnosis of anterior cruciate ligament (ACL) injury but their accuracy is unclear. The purpose of this study is to evaluate the diagnostic accuracy of clinical tests for the diagnosis of ACL injury. Methods Study Design: Systematic review. The review protocol was registered through PROSPERO (CRD42012002069). Electronic databases (PubMed, MEDLINE, EMBASE, CINAHL) were searched up to 19th of June 2013 to identify diagnostic studies comparing the accuracy of clinical tests for ACL injury to an acceptable reference standard (arthroscopy, arthrotomy, or MRI). Risk of bias was appraised using the QUADAS-2 checklist. Index test accuracy was evaluated using a descriptive analysis of paired likelihood ratios and displayed as forest plots. Results A total of 285 full-text articles were assessed for eligibility, from which 14 studies were included in this review. Included studies were deemed to be clinically and statistically heterogeneous, so a meta-analysis was not performed. Nine clinical tests from the history (popping sound at time of injury, giving way, effusion, pain, ability to continue activity) and four from physical examination (anterior draw test, Lachman’s test, prone Lachman’s test and pivot shift test) were investigated for diagnostic accuracy. Inspection of positive and negative likelihood ratios indicated that none of the individual tests provide useful diagnostic information in a clinical setting. Most studies were at risk of bias and reported imprecise estimates of diagnostic accuracy. Conclusion Despite being widely used and accepted in clinical practice, the results of individual history items or physical tests do not meaningfully change the probability of ACL injury. In contrast combinations of tests have higher diagnostic accuracy; however the most accurate combination of clinical tests remains an area for future research. Clinical relevance Clinicians should be aware of the limitations associated with the use of clinical tests for diagnosis of ACL injury. PMID:25187877

  19. The Accuracy of Diagnostic Tests for Lyme Disease in Humans, A Systematic Review and Meta-Analysis of North American Research.

    PubMed

    Waddell, Lisa A; Greig, Judy; Mascarenhas, Mariola; Harding, Shannon; Lindsay, Robbin; Ogden, Nicholas

    2016-01-01

    There has been an increasing incidence of Lyme disease (LD) in Canada and the United States corresponding to the expanding range of the Ixodes tick vector and Lyme disease agent (Borrelia burgdorferi sensu stricto). There are many diagnostic tests for LD available in North America, all of which have some performance issues, and physicians are concerned about the appropriate use and interpretation of these tests. The objective of this systematic review is to summarize the North American evidence on the accuracy of diagnostic tests and test regimes at various stages of LD. Included in the review are 48 studies on diagnostic tests used in North America published since 1995. Thirteen studies examined a two-tier serological test protocol vs. clinical diagnosis, 24 studies examined single assays vs. clinical diagnosis, 9 studies examined single immunoblot vs. clinical diagnosis, 7 studies compared culture or PCR direct detection methods vs. clinical diagnosis, 22 studies compared two or more tests with each other and 8 studies compared a two-tiered serological test protocol to another test. Recent studies examining the sensitivity and specificity of various test protocols noted that the Immunetics® C6 B. burgdorferi ELISA™ and the two tier approach have superior specificity compared to proposed replacements, and the CDC recommended western blot algorithm has equivalent or superior specificity over other proposed test algorithms. There is a dramatic increase in test sensitivity with progression of B. burgdorferi infection from early to late LD. Direct detection methods, culture and PCR of tissue or blood samples were not as sensitive or timely compared to serological testing. It was also noted that there are a large number of both commercial (n = 42) and in-house developed tests used by private laboratories which have not been evaluated in the primary literature.

  20. The Accuracy of Diagnostic Tests for Lyme Disease in Humans, A Systematic Review and Meta-Analysis of North American Research

    PubMed Central

    Lindsay, Robbin; Ogden, Nicholas

    2016-01-01

    There has been an increasing incidence of Lyme disease (LD) in Canada and the United States corresponding to the expanding range of the Ixodes tick vector and Lyme disease agent (Borrelia burgdorferi sensu stricto). There are many diagnostic tests for LD available in North America, all of which have some performance issues, and physicians are concerned about the appropriate use and interpretation of these tests. The objective of this systematic review is to summarize the North American evidence on the accuracy of diagnostic tests and test regimes at various stages of LD. Included in the review are 48 studies on diagnostic tests used in North America published since 1995. Thirteen studies examined a two-tier serological test protocol vs. clinical diagnosis, 24 studies examined single assays vs. clinical diagnosis, 9 studies examined single immunoblot vs. clinical diagnosis, 7 studies compared culture or PCR direct detection methods vs. clinical diagnosis, 22 studies compared two or more tests with each other and 8 studies compared a two-tiered serological test protocol to another test. Recent studies examining the sensitivity and specificity of various test protocols noted that the Immunetics® C6 B. burgdorferi ELISA™ and the two tier approach have superior specificity compared to proposed replacements, and the CDC recommended western blot algorithm has equivalent or superior specificity over other proposed test algorithms. There is a dramatic increase in test sensitivity with progression of B. burgdorferi infection from early to late LD. Direct detection methods, culture and PCR of tissue or blood samples were not as sensitive or timely compared to serological testing. It was also noted that there are a large number of both commercial (n = 42) and in-house developed tests used by private laboratories which have not been evaluated in the primary literature. PMID:28002488

  1. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  2. Comparing the economic and health benefits of different approaches to diagnosing Clostridium difficile infection.

    PubMed

    Bartsch, Sarah M; Umscheid, Craig A; Nachamkin, Irving; Hamilton, Keith; Lee, Bruce Y

    2015-01-01

    Accurate diagnosis of Clostridium difficile infection (CDI) is essential to effectively managing patients and preventing transmission. Despite the availability of several diagnostic tests, the optimal strategy is debatable and their economic values are unknown. We modified our previously existing C. difficile simulation model to determine the economic value of different CDI diagnostic approaches from the hospital perspective. We evaluated four diagnostic methods for a patient suspected of having CDI: 1) toxin A/B enzyme immunoassay, 2) glutamate dehydrogenase (GDH) antigen/toxin AB combined in one test, 3) nucleic acid amplification test (NAAT), and 4) GDH antigen/toxin AB combination test with NAAT confirmation of indeterminate results. Sensitivity analysis varied the proportion of those tested with clinically significant diarrhoea, the probability of CDI, NAAT cost and CDI treatment delay resulting from a false-negative test, length of stay and diagnostic sensitivity and specificity. The GDH/toxin AB plus NAAT approach leads to the timeliest treatment with the fewest unnecessary treatments given, resulted in the best bed management and generated the lowest cost. The NAAT-alone approach also leads to timely treatment. The GDH/toxin AB diagnostic (without NAAT confirmation) approach resulted in a large number of delayed treatments, but results in the fewest secondary colonisations. Results were robust to the sensitivity analysis. Choosing the right diagnostic approach is a matter of cost and test accuracy. GDH/toxin AB plus NAAT diagnosis led to the timeliest treatment and was the least costly. Copyright © 2014 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  3. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference

    PubMed Central

    Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth

    2015-01-01

    Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275

  4. Development, Evaluation, and Integration of a Quantitative Reverse-Transcription Polymerase Chain Reaction Diagnostic Test for Ebola Virus on a Molecular Diagnostics Platform

    PubMed Central

    Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B.; Nauwelaers, David; Ariën, Kevin K.

    2016-01-01

    Background. The 2013–2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV). Methods. The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus. Results. The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%. Conclusions. The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. PMID:27247341

  5. Predictive values of thermal and electrical dental pulp tests: a clinical study.

    PubMed

    Villa-Chávez, Carlos E; Patiño-Marín, Nuria; Loyola-Rodríguez, Juan P; Zavala-Alonso, Norma V; Martínez-Castañón, Gabriel A; Medina-Solís, Carlo E

    2013-08-01

    For a diagnostic test to be useful, it is necessary to determine the probability that the test will provide the correct diagnosis. Therefore, it is necessary to calculate the predictive value of diagnostics. The aim of the present study was to identify the sensitivity, specificity, positive and negative predictive values, accuracy, and reproducibility of thermal and electrical tests of pulp sensitivity. The thermal tests studied were the 1, 1, 1, 2-tetrafluoroethane (cold) and hot gutta-percha (hot) tests. For the electrical test, the Analytic Technology Pulp Tester (Analytic Technology, Redmond, WA) was used. A total of 110 teeth were tested: 60 teeth with vital pulp and 50 teeth with necrotic pulps (disease prevalence of 45%). The ideal standard was established by direct pulp inspection. The sensitivities of the diagnostic tests were 0.88 for the cold test, 0.86 for the heat test, and 0.76 for the electrical test, and the specificity was 1.0 for all 3 tests. The negative predictive value was 0.90 for the cold test, 0.89 for the heat test, and 0.83 for the electrical test, and the positive predictive value was 1.0 for all 3 tests. The highest accuracy (0.94) and reproducibility (0.88) were observed for the cold test. The cold test was the most accurate method for diagnostic testing. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  6. 9 CFR 93.406 - Diagnostic tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., method of testing, names of consignor and consignee, and a description of the goats, including breed..., names of the consignor and consignee, and a description of the cattle, with breed, ages, and markings... herd of origin tested negative to a whole herd test. (b) Tuberculosis and brucellosis tests of goats...

  7. Are the classic diagnostic methods in mycology still state of the art?

    PubMed

    Wiegand, Cornelia; Bauer, Andrea; Brasch, Jochen; Nenoff, Pietro; Schaller, Martin; Mayser, Peter; Hipler, Uta-Christina; Elsner, Peter

    2016-05-01

    The diagnostic workup of cutaneous fungal infections is traditionally based on microscopic KOH preparations as well as culturing of the causative organism from sample material. Another possible option is the detection of fungal elements by dermatohistology. If performed correctly, these methods are generally suitable for the diagnosis of mycoses. However, the advent of personalized medicine and the tasks arising therefrom require new procedures marked by simplicity, specificity, and swiftness. The additional use of DNA-based molecular techniques further enhances sensitivity and diagnostic specificity, and reduces the diagnostic interval to 24-48 hours, compared to weeks required for conventional mycological methods. Given the steady evolution in the field of personalized medicine, simple analytical PCR-based systems are conceivable, which allow for instant diagnosis of dermatophytes in the dermatology office (point-of-care tests). © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  8. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.

    PubMed Central

    Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen

    2006-01-01

    OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726

  9. Antidiuretic hormone blood test

    MedlinePlus

    ... eds. Laboratory Tests and Diagnostic Procedures . 6th ed. St Louis, MO: Elsevier Saunders; 2013:146. Guber HA, ... Diagnosis and Management by Laboratory Methods . 23rd ed. St Louis, MO: Elsevier; 2017:chap 24. Oh MS, ...

  10. Diagnostic sensitivity and specificity of in situ hybridization and immunohistochemistry for Eastern equine encephalitis virus and West Nile virus in formalin-fixed, paraffin-embedded brain tissue of horses.

    PubMed

    Pennick, Kate E; McKnight, Christy A; Patterson, Jon S; Latimer, Kenneth S; Maes, Roger K; Wise, Annabel G; Kiupel, Matti

    2012-03-01

    Immunohistochemistry (IHC) and in situ hybridization (ISH) can be used either to detect or to differentiate between Eastern equine encephalitis virus (EEEV) and West Nile virus (WNV) within formalin-fixed, paraffin-embedded (FFPE) brain tissue of horses. To compare the diagnostic sensitivity and specificity of ISH and IHC, FFPE brain tissue from 20 EEEV-positive horses and 16 WNV-positive horses were tested with both EEEV and WNV oligoprobes and EEEV- and WNV-specific antibodies. Reverse transcription polymerase chain reaction (RT-PCR) for detection of EEEV and WNV was used as the gold standard to confirm infection. All horses that tested positive for EEEV by RT-PCR also tested positive by IHC and ISH, except for 1 case that was false-negative by ISH. In contrast, all horses that tested positive for WNV by RT-PCR tested negative by IHC and only 2 horses tested positive by ISH. No false-positives were detected with either method for both viruses. Both IHC and ISH are highly specific and sensitive diagnostic methods to detect EEEV in equine FFPE brain tissues, although neither appear effective for the diagnosis of WNV in equine neurologic cases.

  11. Transforming information from silicon testing and design characterization into numerical data sets for yield learning

    NASA Astrophysics Data System (ADS)

    Yang, Thomas; Shen, Yang; Zhang, Yifan; Sweis, Jason; Lai, Ya-Chieh

    2017-03-01

    Silicon testing results are regularly collected for a particular lot of wafers to study yield loss from test result diagnostics. Product engineers will analyze the diagnostic results and perform a number of physical failure analyses to detect systematic defects which cause yield loss for these sets of wafers in order to feedback the information to process engineers for process improvements. Most of time, the systematic defects that are detected are major issues or just one of the causes for the overall yield loss. This paper will present a working flow for using design analysis techniques combined with diagnostic methods to systematically transform silicon testing information into physical layout information. A new set of the testing results are received from a new lot of wafers for the same product. We can then correlate all the diagnostic results from different periods of time to check which blocks or nets have been highlighted or stop occurring on the failure reports in order to monitor process changes which impact the yield. The design characteristic analysis flow is also implemented to find 1) the block connections on a design that have failed electrical test or 2) frequently used cells that been highlighted multiple times.

  12. [Intestinal parasitic diseases in children].

    PubMed

    Mare, Anca; Man, A; Toma, Felicia; Székely, Edit; Lôrinczi, Lilla; Sipoş, Anca

    2007-01-01

    To compare the incidence of intestinal parasitosis between children with residence in urban and rural areas: to compare the efficacy of parasitologic diagnostic methods. In our study we included two lots of children. The first lot consisted in 74 children from rural areas from which we collected 44 samples of feces and 55 samples for the "Scotch tape" test. The second lot consisted in 214 children from urban areas from which we collected 44 samples of feces. We examined each sample of feces by three different methods. The study was performed between April to June 2006. The incidence of intestinal parasitosis increases in children from urban areas towards rural areas, and in children between 5 and 10 years. Ascariasis is the most frequent disease in both urban and rural areas. By examination of each fecal sample by three different methods, the number of positive cases increased. The residence in rural areas and age between 5 to 10 years are risk factors for intestinal parasitosis. The "Scotch tape" test was more efficient in Enterobius vermicularis infection than the methods performed from feces. We recommend using at the same time three diagnostic methods for feces examination to improve the diagnostic sensibility.

  13. A survey of statistics in three UK general practice journal

    PubMed Central

    Rigby, Alan S; Armstrong, Gillian K; Campbell, Michael J; Summerton, Nick

    2004-01-01

    Background Many medical specialities have reviewed the statistical content of their journals. To our knowledge this has not been done in general practice. Given the main role of a general practitioner as a diagnostician we thought it would be of interest to see whether the statistical methods reported reflect the diagnostic process. Methods Hand search of three UK journals of general practice namely the British Medical Journal (general practice section), British Journal of General Practice and Family Practice over a one-year period (1 January to 31 December 2000). Results A wide variety of statistical techniques were used. The most common methods included t-tests and Chi-squared tests. There were few articles reporting likelihood ratios and other useful diagnostic methods. There was evidence that the journals with the more thorough statistical review process reported a more complex and wider variety of statistical techniques. Conclusions The BMJ had a wider range and greater diversity of statistical methods than the other two journals. However, in all three journals there was a dearth of papers reflecting the diagnostic process. Across all three journals there were relatively few papers describing randomised controlled trials thus recognising the difficulty of implementing this design in general practice. PMID:15596014

  14. Requirements for diagnosis of malaria at different levels of the laboratory network in Africa.

    PubMed

    Long, Earl G

    2009-06-01

    The rapid increase of resistance to cheap, reliable antimalarials, the increasing cost of effective drugs, and the low specificity of clinical diagnosis has increased the need for more reliable diagnostic methods for malaria. The most commonly used and most reliable remains microscopic examination of stained blood smears, but this technique requires skilled personnel, precision instruments, and ideally a source of electricity. Microscopy has the advantage of enabling the examiner to identify the species, stage, and density of an infection. An alternative to microscopy is the rapid diagnostic test (RDT), which uses a labeled monoclonal antibody to detect circulating parasitic antigens. This test is most commonly used to detect Plasmodium falciparum infections and is available in a plastic cassette format. Both microscopy and RDTs should be available at all levels of laboratory service in endemic areas, but in peripheral laboratories with minimally trained staff, the RDT may be a more practical diagnostic method.

  15. Preanalytics in lung cancer.

    PubMed

    Warth, Arne; Muley, Thomas; Meister, Michael; Weichert, Wilko

    2015-01-01

    Preanalytic sampling techniques and preparation of tissue specimens strongly influence analytical results in lung tissue diagnostics both on the morphological but also on the molecular level. However, in contrast to analytics where tremendous achievements in the last decade have led to a whole new portfolio of test methods, developments in preanalytics have been minimal. This is specifically unfortunate in lung cancer, where usually only small amounts of tissue are at hand and optimization in all processing steps is mandatory in order to increase the diagnostic yield. In the following, we provide a comprehensive overview on some aspects of preanalytics in lung cancer from the method of sampling over tissue processing to its impact on analytical test results. We specifically discuss the role of preanalytics in novel technologies like next-generation sequencing and in the state-of the-art cytology preparations. In addition, we point out specific problems in preanalytics which hamper further developments in the field of lung tissue diagnostics.

  16. The diagnostic test accuracy of magnetic resonance imaging, magnetic resonance arthrography and computer tomography in the detection of chondral lesions of the hip.

    PubMed

    Smith, Toby O; Simpson, Michael; Ejindu, Vivian; Hing, Caroline B

    2013-04-01

    The purpose of this study was to assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and multidetector arrays in CT arthrography (MDCT) for assessing chondral lesions in the hip joint. A review of the published and unpublished literature databases was performed to identify all studies reporting the diagnostic test accuracy (sensitivity/specificity) of MRI, MRA or MDCT for the assessment of adults with chondral (cartilage) lesions of the hip with surgical comparison (arthroscopic or open) as the reference test. All included studies were reviewed using the quality assessment of diagnostic accuracy studies appraisal tool. Pooled sensitivity, specificity, likelihood ratios and diagnostic odds ratios were calculated with 95 % confidence intervals using a random-effects meta-analysis for MRI, MRA and MDCT imaging. Eighteen studies satisfied the eligibility criteria. These included 648 hips from 637 patients. MRI indicated a pooled sensitivity of 0.59 (95 % CI: 0.49-0.70) and specificity of 0.94 (95 % CI: 0.90-0.97), and MRA sensitivity and specificity values were 0.62 (95 % CI: 0.57-0.66) and 0.86 (95 % CI: 0.83-0.89), respectively. The diagnostic test accuracy for the detection of hip joint cartilage lesions is currently superior for MRI compared with MRA. There were insufficient data to perform meta-analysis for MDCT or CTA protocols. Based on the current limited diagnostic test accuracy of the use of magnetic resonance or CT, arthroscopy remains the most accurate method of assessing chondral lesions in the hip joint.

  17. Constructing and Implementing a Four Tier Test about Static Electricity to Diagnose Pre-service Elementary School Teacher’ Misconceptions

    NASA Astrophysics Data System (ADS)

    Hermita, N.; Suhandi, A.; Syaodih, E.; Samsudin, A.; Isjoni; Johan, H.; Rosa, F.; Setyaningsih, R.; Sapriadil; Safitri, D.

    2017-09-01

    We have already constructed and implemented the diagnostic test formed in the four tier test to diagnose pre-service elementary teachers’ misconceptions about static electricity. The method which is utilized in this study is 3D-1I (Define, Design, Develop and Implementation) conducted to the pre-service elementary school teachers. The number of respondents involved in the study is 78 students of PGSD FKIP Universitas Riau. The data was collected by administering diagnostic test items in the form of four tier test. The result indicates that there are several misconceptions related to static electricity concept, these include: 1) Electrostatic objects cannot attract neutral objects, 2) A neutral object is an object that does not contain an electrical charge, and 3) the magnitude of the tensile force between two charged objects depends on the size of the charge. Moreover, the research’s results establish that the diagnostic test is able to analyse number of misconceptions and classify level of understanding pre-service elementary school teachers that is scientific knowledge, misconception, lack knowledge, and error. In conclusion, the diagnostic test item in the form of four tier test has already been constructed and implemented to diagnose students’ conceptions on static electricity.

  18. Modification of the Integrated Sasang Constitutional Diagnostic Model

    PubMed Central

    Nam, Jiho

    2017-01-01

    In 2012, the Korea Institute of Oriental Medicine proposed an objective and comprehensive physical diagnostic model to address quantification problems in the existing Sasang constitutional diagnostic method. However, certain issues have been raised regarding a revision of the proposed diagnostic model. In this paper, we propose various methodological approaches to address the problems of the previous diagnostic model. Firstly, more useful variables are selected in each component. Secondly, the least absolute shrinkage and selection operator is used to reduce multicollinearity without the modification of explanatory variables. Thirdly, proportions of SC types and age are considered to construct individual diagnostic models and classify the training set and the test set for reflecting the characteristics of the entire dataset. Finally, an integrated model is constructed with explanatory variables of individual diagnosis models. The proposed integrated diagnostic model significantly improves the sensitivities for both the male SY type (36.4% → 62.0%) and the female SE type (43.7% → 64.5%), which were areas of limitation of the previous integrated diagnostic model. The ideas of these new algorithms are expected to contribute not only to the scientific development of Sasang constitutional medicine in Korea but also to that of other diagnostic methods for traditional medicine. PMID:29317897

  19. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology.

    PubMed

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, Br

    2012-01-01

    The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol-formalin as a fixative agent. Statistical analysis with the 'z test' was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ(2)test was used to identify the additional yield for malignancy by the CB method. Cellularity and additional yield for malignancy was 15% more by the CB method. The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method.

  20. Inventions leading to the development of the diagnostic test kit industry--from the modern pregnancy test to the sandwich assays.

    PubMed

    Wide, Leif

    2005-01-01

    The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some crucial steps of the innovation processes.

  1. Improving Papanicolaou test quality and reducing medical errors by using Toyota production system methods.

    PubMed

    Raab, Stephen S; Andrew-Jaja, Carey; Condel, Jennifer L; Dabbs, David J

    2006-01-01

    The objective of the study was to determine whether the Toyota production system process improves Papanicolaou test quality and patient safety. An 8-month nonconcurrent cohort study that included 464 case and 639 control women who had a Papanicolaou test was performed. Office workflow was redesigned using Toyota production system methods by introducing a 1-by-1 continuous flow process. We measured the frequency of Papanicolaou tests without a transformation zone component, follow-up and Bethesda System diagnostic frequency of atypical squamous cells of undetermined significance, and diagnostic error frequency. After the intervention, the percentage of Papanicolaou tests lacking a transformation zone component decreased from 9.9% to 4.7% (P = .001). The percentage of Papanicolaou tests with a diagnosis of atypical squamous cells of undetermined significance decreased from 7.8% to 3.9% (P = .007). The frequency of error per correlating cytologic-histologic specimen pair decreased from 9.52% to 7.84%. The introduction of the Toyota production system process resulted in improved Papanicolaou test quality.

  2. How recent advances in molecular tests could impact the diagnosis of pneumonia.

    PubMed

    Murdoch, David R

    2016-01-01

    Molecular diagnostic tests have been the single major development in pneumonia diagnostics over recent years. Nucleic acid detection tests (NATs) have greatly improved the ability to detect respiratory viruses and bacterial pathogens that do not normally colonize the respiratory tract. In contrast, NATs do not yet have an established role for diagnosing pneumonia caused by bacteria that commonly colonize the nasopharynx due to difficulties discriminating between pathogens and coincidental carriage strains. New approaches are needed to distinguish infection from colonization, such as through use of quantitative methods and identification of discriminating cut-off levels. The recent realization that the lung microbiome exists has provided new insights into the pathogenesis of pneumonia involving the interaction between multiple microorganisms. New developments in molecular diagnostics must account for this new paradigm.

  3. The way to universal and correct medical presentation of diagnostic informations for complex spectrophotometry noninvasive medical diagnostic systems

    NASA Astrophysics Data System (ADS)

    Rogatkin, Dmitrii A.; Tchernyi, Vladimir V.

    2003-07-01

    The optical noninvasive diagnostic systems are now widely applied and investigated in different areas of medicine. One of the such techniques is the noninvasive spectrophotometry, the complex diagnostic technique consisting on elastic scattering spectroscopy, absorption spectroscopy, fluorescent diagnostics, photoplethismography, etc. Today a lot of real optical diagnostic systems indicate the technical parameters and physical data only as a result of the diagnostic procedure. But, it is clear that for the medical staff the more convenient medical information is needed. This presentation lights the general way for development a diagnostic system"s software, which can produce the full processing of the diagnostic data from a physical to a medical level. It is shown, that this process is a multilevel (3-level) procedure and the main diagnostic result for noninvasive spectrophotometry methods, the biochemical and morphological composition of the tested tissues, arises in it on a second level of calculations.

  4. Accuracy of Immunofluorescence in the Diagnosis of Primary Ciliary Dyskinesia

    PubMed Central

    Frost, Emily; Dixon, Mellisa; Ollosson, Sarah; Kilpin, Kate; Patel, Mitali; Scully, Juliet; Rogers, Andrew V.; Mitchison, Hannah M.; Bush, Andrew; Hogg, Claire

    2017-01-01

    Rationale: The standard approach to diagnosis of primary ciliary dyskinesia (PCD) in the United Kingdom consists of assessing ciliary function by high-speed microscopy and ultrastructure by election microscopy, but equipment and expertise is not widely available internationally. The identification of biallelic disease-causing mutations is also diagnostic, but many disease-causing genes are unknown, and testing is not widely available outside the United States. Fluorescent antibodies to ciliary proteins are used to validate research genetic studies, but diagnostic utility in this disease has not been systematically evaluated. Objectives: To determine utility of a panel of six fluorescent labeled antibodies as a diagnostic tool for PCD. Methods: The study used immunofluorescent labeling of nasal brushings from a discovery cohort of 35 patients diagnosed with PCD by ciliary ultrastructure, and a diagnostic accuracy cohort of 386 patients referred with symptoms suggestive of disease. The results were compared with diagnostic outcome. Measurements and Main Results: Immunofluorescence correctly identified mislocalized or absent staining in 100% of the discovery cohort. In the diagnostic cohort immunofluorescence successfully identified 22 of 25 patients with PCD and normal staining in all 252 in whom PCD was considered highly unlikely. In addition, immunofluorescence provided a result in 55% (39) of cases that were previously inconclusive. Immunofluorescence results were available within 14 days, costing $187 per sample compared with electron microscopy (27 days; cost $1,452). Conclusions: Immunofluorescence is a highly specific diagnostic test for PCD, and it improves the speed and availability of diagnostic testing. However, sensitivity is limited and immunofluorescence is not suitable as a stand-alone test. PMID:28199173

  5. Evaluation of an inhouse rapid ELISA test for detection of giardia in domestic sheep (Ovis aries).

    PubMed

    Wilson, Jolaine M; Hankenson, F Claire

    2010-11-01

    Sheep (Ovis aries) are increasingly used at our institution as models of human disease. Within the research environment, routine husbandry and handling of sheep has potential for transmission of zoonotic agents, including Giardia. The prevalence of Giardia in sheep may approach 68%. Classic diagnostic testing involves microscopic examination for fecal cysts or trophozoites; however, limitations of microscopy include time, labor, and potential false-negative results due to intermittent shedding. We wished to determine whether a commercial rapid ELISA used for Giardia detection in dogs and cats could be used in sheep. Fecal samples collected from sheep (n = 93) were tested with a combination of 6 methods: reference laboratory fecal flotation, reference laboratory ELISA, inhouse fecal flotation, and commercially available tests (enzyme immunoassay, direct fluorescence antibody assay, and rapid ELISA). Prevalence of Giardia infection in facility sheep was 11.8% (11 of 93 animals). Of the 11 samples considered positive, 3 were confirmed by multiple testing methods, and 5 were positive by microscopy alone. Inhouse fecal flotation for 8 samples was positive on only 1 of 2 consecutive testing days. The rapid ELISA test exhibited 0% sensitivity for sheep giardiasis. Overall, the examined methods had low sensitivities and low positive predictive values. Despite limitations, microscopic analysis of repeat fecal samples remained the most accurate diagnostic method for ovine giardiasis among the methods tested.

  6. Evidence-Based Toxicology.

    PubMed

    Hoffmann, Sebastian; Hartung, Thomas; Stephens, Martin

    Evidence-based toxicology (EBT) was introduced independently by two groups in 2005, in the context of toxicological risk assessment and causation as well as based on parallels between the evaluation of test methods in toxicology and evidence-based assessment of diagnostics tests in medicine. The role model of evidence-based medicine (EBM) motivated both proposals and guided the evolution of EBT, whereas especially systematic reviews and evidence quality assessment attract considerable attention in toxicology.Regarding test assessment, in the search of solutions for various problems related to validation, such as the imperfectness of the reference standard or the challenge to comprehensively evaluate tests, the field of Diagnostic Test Assessment (DTA) was identified as a potential resource. DTA being an EBM discipline, test method assessment/validation therefore became one of the main drivers spurring the development of EBT.In the context of pathway-based toxicology, EBT approaches, given their objectivity, transparency and consistency, have been proposed to be used for carrying out a (retrospective) mechanistic validation.In summary, implementation of more evidence-based approaches may provide the tools necessary to adapt the assessment/validation of toxicological test methods and testing strategies to face the challenges of toxicology in the twenty first century.

  7. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. A comparison of bivariate, multivariate random-effects, and Poisson correlated gamma-frailty models to meta-analyze individual patient data of ordinal scale diagnostic tests.

    PubMed

    Simoneau, Gabrielle; Levis, Brooke; Cuijpers, Pim; Ioannidis, John P A; Patten, Scott B; Shrier, Ian; Bombardier, Charles H; de Lima Osório, Flavia; Fann, Jesse R; Gjerdingen, Dwenda; Lamers, Femke; Lotrakul, Manote; Löwe, Bernd; Shaaban, Juwita; Stafford, Lesley; van Weert, Henk C P M; Whooley, Mary A; Wittkampf, Karin A; Yeung, Albert S; Thombs, Brett D; Benedetti, Andrea

    2017-11-01

    Individual patient data (IPD) meta-analyses are increasingly common in the literature. In the context of estimating the diagnostic accuracy of ordinal or semi-continuous scale tests, sensitivity and specificity are often reported for a given threshold or a small set of thresholds, and a meta-analysis is conducted via a bivariate approach to account for their correlation. When IPD are available, sensitivity and specificity can be pooled for every possible threshold. Our objective was to compare the bivariate approach, which can be applied separately at every threshold, to two multivariate methods: the ordinal multivariate random-effects model and the Poisson correlated gamma-frailty model. Our comparison was empirical, using IPD from 13 studies that evaluated the diagnostic accuracy of the 9-item Patient Health Questionnaire depression screening tool, and included simulations. The empirical comparison showed that the implementation of the two multivariate methods is more laborious in terms of computational time and sensitivity to user-supplied values compared to the bivariate approach. Simulations showed that ignoring the within-study correlation of sensitivity and specificity across thresholds did not worsen inferences with the bivariate approach compared to the Poisson model. The ordinal approach was not suitable for simulations because the model was highly sensitive to user-supplied starting values. We tentatively recommend the bivariate approach rather than more complex multivariate methods for IPD diagnostic accuracy meta-analyses of ordinal scale tests, although the limited type of diagnostic data considered in the simulation study restricts the generalization of our findings. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Aerospike Engine Post-Test Diagnostic System Delivered to Rocketdyne

    NASA Technical Reports Server (NTRS)

    Meyer, Claudia M.

    2000-01-01

    The NASA Glenn Research Center at Lewis Field, in cooperation with Rocketdyne, has designed, developed, and implemented an automated Post-Test Diagnostic System (PTDS) for the X-33 linear aerospike engine. The PTDS was developed to reduce analysis time and to increase the accuracy and repeatability of rocket engine ground test fire and flight data analysis. This diagnostic system provides a fast, consistent, first-pass data analysis, thereby aiding engineers who are responsible for detecting and diagnosing engine anomalies from sensor data. It uses analytical methods modeled after the analysis strategies used by engineers. Glenn delivered the first version of PTDS in September of 1998 to support testing of the engine s power pack assembly. The system was used to analyze all 17 power pack tests and assisted Rocketdyne engineers in troubleshooting both data acquisition and test article anomalies. The engine version of PTDS, which was delivered in June of 1999, will support all single-engine, dual-engine, and flight firings of the aerospike engine.

  10. Rapid tests for diagnosis of leptospirosis: current tools and emerging technologies.

    PubMed

    Picardeau, Mathieu; Bertherat, Eric; Jancloes, Michel; Skouloudis, Andreas N; Durski, Kara; Hartskeerl, Rudy A

    2014-01-01

    Leptospirosis is an emerging zoonosis with a worldwide distribution but is more commonly found in impoverished populations in developing countries and tropical regions with frequent flooding. The rapid detection of leptospirosis is a critical step to effectively manage the disease and to control outbreaks in both human and animal populations. Therefore, there is a need for accurate and rapid diagnostic tests and appropriate surveillance and alert systems to identify outbreaks. This review describes current in-house methods and commercialized tests for the rapid diagnosis of acute leptospirosis. It focuses on diagnostic tests that can be performed with minimal training and limited equipment in less-developed and newly industrialized countries, particularly in resource-limited settings and with results in minutes to less than 4 hours. We also describe recent technological advances in the field of diagnostic tests that could allow for the development of innovative rapid tests in the near future. © 2013 Elsevier Inc. All rights reserved.

  11. [Computer diagnosis of traumatic impact by hepatic lesion].

    PubMed

    Kimbar, V I; Sevankeev, V V

    2007-01-01

    A method of computer-assisted diagnosis of traumatic affection by liver damage (HEPAR-test program) is described. The program is based on calculated diagnostic coefficients using Bayes' probability method with Wald's recognition procedure.

  12. A Gram Stain Hands-On Workshop Enhances First Year Medical Students' Technique Competency in Comprehension and Memorization.

    PubMed

    Delfiner, Matthew S; Martinez, Luis R; Pavia, Charles S

    2016-01-01

    Laboratory diagnostic tests have an essential role in patient care, and the increasing number of medical and health professions schools focusing on teaching laboratory medicine to pre-clinical students reflects this importance. However, data validating the pedagogical methods that best influence students' comprehension and interpretation of diagnostic tests have not been well described. The Gram stain is a simple yet significant and frequently used diagnostic test in the clinical setting that helps classify bacteria into two major groups, Gram positive and negative, based on their cell wall structure. We used this technique to assess which educational strategies may improve students' learning and competency in medical diagnostic techniques. Hence, in this randomized controlled study, we compared the effectiveness of several educational strategies (e.g. workshop, discussion, or lecture) in first year medical students' competency in comprehension and interpretation of the Gram stain procedure. We demonstrated that a hands-on practical workshop significantly enhances students' competency in memorization and overall comprehension of the technique. Interestingly, most students irrespective of their cohort showed difficulty in answering Gram stain-related analytical questions, suggesting that more emphasis should be allocated by the instructors to clearly explain the interpretation of the diagnostic test results to students in medical and health professional schools. This proof of principle study highlights the need of practical experiences on laboratory medical techniques during pre-clinical training to facilitate future medical doctors' and healthcare professionals' basic understanding and competency in diagnostic testing for better patient care.

  13. Method of Testing and Predicting Failures of Electronic Mechanical Systems

    NASA Technical Reports Server (NTRS)

    Iverson, David L.; Patterson-Hine, Frances A.

    1996-01-01

    A method employing a knowledge base of human expertise comprising a reliability model analysis implemented for diagnostic routines is disclosed. The reliability analysis comprises digraph models that determine target events created by hardware failures human actions, and other factors affecting the system operation. The reliability analysis contains a wealth of human expertise information that is used to build automatic diagnostic routines and which provides a knowledge base that can be used to solve other artificial intelligence problems.

  14. Diagnostic trends in Clostridium difficile detection in Finnish microbiology laboratories.

    PubMed

    Könönen, Eija; Rasinperä, Marja; Virolainen, Anni; Mentula, Silja; Lyytikäinen, Outi

    2009-12-01

    Due to increased interest directed to Clostridium difficile-associated infections, a questionnaire survey of laboratory diagnostics of toxin-producing C. difficile was conducted in Finland in June 2006. Different aspects pertaining to C. difficile diagnosis, such as requests and criteria used for testing, methods used for its detection, yearly changes in diagnostics since 1996, and the total number of investigations positive for C. difficile in 2005, were asked in the questionnaire, which was sent to 32 clinical microbiology laboratories, including all hospital-affiliated and the relevant private clinical microbiology laboratories in Finland. The situation was updated by phone and email correspondence in September 2008. In June 2006, 28 (88%) laboratories responded to the questionnaire survey; 24 of them reported routinely testing requested stool specimens for C. difficile. Main laboratory methods included toxin detection (21/24; 88%) and/or anaerobic culture (19/24; 79%). In June 2006, 18 (86%) of the 21 laboratories detecting toxins directly from feces, from the isolate, or both used methods for both toxin A (TcdA) and B (TcdB), whereas only one laboratory did so in 1996. By September 2008, all of the 23 laboratories performing diagnostics for C. difficile used methods for both TcdA and TcdB. In 2006, the number of specimens processed per 100,000 population varied remarkably between different hospital districts. In conclusion, culturing C. difficile is common and there has been a favorable shift in toxin detection practice in Finnish clinical microbiology laboratories. However, the variability in diagnostic activity reported in 2006 creates a challenge for national monitoring of the epidemiology of C. difficile and related diseases.

  15. [Detection of rubella virus RNA in clinical material by real time polymerase chain reaction method].

    PubMed

    Domonova, É A; Shipulina, O Iu; Kuevda, D A; Larichev, V F; Safonova, A P; Burchik, M A; Butenko, A M; Shipulin, G A

    2012-01-01

    Development of a reagent kit for detection of rubella virus RNA in clinical material by PCR-RT. During development and determination of analytical specificity and sensitivity DNA and RNA of 33 different microorganisms including 4 rubella strains were used. Comparison of analytical sensitivity of virological and molecular-biological methods was performed by using rubella virus strains Wistar RA 27/3, M-33, "Orlov", Judith. Evaluation of diagnostic informativity of rubella virus RNAisolation in various clinical material by PCR-RT method was performed in comparison with determination of virus specific serum antibodies by enzyme immunoassay. A reagent kit for the detection of rubella virus RNA in clinical material by PCR-RT was developed. Analytical specificity was 100%, analytical sensitivity - 400 virus RNA copies per ml. Analytical sensitivity of the developed technique exceeds analytical sensitivity of the Vero E6 cell culture infection method in studies of rubella virus strains Wistar RA 27/3 and "Orlov" by 11g and 31g, and for M-33 and Judith strains is analogous. Diagnostic specificity is 100%. Diagnostic specificity for testing samples obtained within 5 days of rash onset: for peripheral blood sera - 20.9%, saliva - 92.5%, nasopharyngeal swabs - 70.1%, saliva and nasopharyngeal swabs - 97%. Positive and negative predictive values of the results were shown depending on the type of clinical material tested. Application of reagent kit will allow to increase rubella diagnostics effectiveness at the early stages of infectious process development, timely and qualitatively perform differential diagnostics of exanthema diseases, support tactics of anti-epidemic regime.

  16. Towards a Standard Psychometric Diagnostic Interview for Subjects at Ultra High Risk of Psychosis: CAARMS versus SIPS

    PubMed Central

    Fusar-Poli, P.; Cappucciati, M.; Rutigliano, G.; Lee, T. Y.; Beverly, Q.; Bonoldi, I.; Lelli, J.; Kaar, S. J.; Gago, E.; Rocchetti, M.; Patel, R.; Bhavsar, V.; Tognin, S.; Badger, S.; Calem, M.; Lim, K.; Kwon, J. S.; Perez, J.; McGuire, P.

    2016-01-01

    Background. Several psychometric instruments are available for the diagnostic interview of subjects at ultra high risk (UHR) of psychosis. Their diagnostic comparability is unknown. Methods. All referrals to the OASIS (London) or CAMEO (Cambridgeshire) UHR services from May 13 to Dec 14 were interviewed for a UHR state using both the CAARMS 12/2006 and the SIPS 5.0. Percent overall agreement, kappa, the McNemar-Bowker χ 2 test, equipercentile methods, and residual analyses were used to investigate diagnostic outcomes and symptoms severity or frequency. A conversion algorithm (CONVERT) was validated in an independent UHR sample from the Seoul Youth Clinic (Seoul). Results. There was overall substantial CAARMS-versus-SIPS agreement in the identification of UHR subjects (n = 212, percent overall agreement = 86%; kappa = 0.781, 95% CI from 0.684 to 0.878; McNemar-Bowker test = 0.069), with the exception of the brief limited intermittent psychotic symptoms (BLIPS) subgroup. Equipercentile-linking table linked symptoms severity and frequency across the CAARMS and SIPS. The conversion algorithm was validated in 93 UHR subjects, showing excellent diagnostic accuracy (CAARMS to SIPS: ROC area 0.929; SIPS to CAARMS: ROC area 0.903). Conclusions. This study provides initial comparability data between CAARMS and SIPS and will inform ongoing multicentre studies and clinical guidelines for the UHR psychometric diagnostic interview. PMID:27314005

  17. Incorporating uncertainty into medical decision making: an approach to unexpected test results.

    PubMed

    Bianchi, Matt T; Alexander, Brian M; Cash, Sydney S

    2009-01-01

    The utility of diagnostic tests derives from the ability to translate the population concepts of sensitivity and specificity into information that will be useful for the individual patient: the predictive value of the result. As the array of available diagnostic testing broadens, there is a temptation to de-emphasize history and physical findings and defer to the objective rigor of technology. However, diagnostic test interpretation is not always straightforward. One significant barrier to routine use of probability-based test interpretation is the uncertainty inherent in pretest probability estimation, the critical first step of Bayesian reasoning. The context in which this uncertainty presents the greatest challenge is when test results oppose clinical judgment. It is this situation when decision support would be most helpful. The authors propose a simple graphical approach that incorporates uncertainty in pretest probability and has specific application to the interpretation of unexpected results. This method quantitatively demonstrates how uncertainty in disease probability may be amplified when test results are unexpected (opposing clinical judgment), even for tests with high sensitivity and specificity. The authors provide a simple nomogram for determining whether an unexpected test result suggests that one should "switch diagnostic sides.'' This graphical framework overcomes the limitation of pretest probability uncertainty in Bayesian analysis and guides decision making when it is most challenging: interpretation of unexpected test results.

  18. Evaluation of the diagnostic accuracy of CareStart G6PD deficiency Rapid Diagnostic Test (RDT) in a malaria endemic area in Ghana, Africa.

    PubMed

    Adu-Gyasi, Dennis; Asante, Kwaku Poku; Newton, Sam; Dosoo, David; Amoako, Sabastina; Adjei, George; Amoako, Nicholas; Ankrah, Love; Tchum, Samuel Kofi; Mahama, Emmanuel; Agyemang, Veronica; Kayan, Kingsley; Owusu-Agyei, Seth

    2015-01-01

    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most widespread enzyme defect that can result in red cell breakdown under oxidative stress when exposed to certain medicines including antimalarials. We evaluated the diagnostic accuracy of CareStart G6PD deficiency Rapid Diagnostic Test (RDT) as a point-of-care tool for screening G6PD deficiency. A cross-sectional study was conducted among 206 randomly selected and consented participants from a group with known G6PD deficiency status between February 2013 and June 2013. A maximum of 1.6ml of capillary blood samples were used for G6PD deficiency screening using CareStart G6PD RDT and Trinity qualitative with Trinity quantitative methods as the "gold standard". Samples were also screened for the presence of malaria parasites. Data entry and analysis were done using Microsoft Access 2010 and Stata Software version 12. Kintampo Health Research Centre Institutional Ethics Committee granted ethical approval. The sensitivity (SE) and specificity (SP) of CareStart G6PD deficiency RDT was 100% and 72.1% compared to Trinity quantitative method respectively and was 98.9% and 96.2% compared to Trinity qualitative method. Malaria infection status had no significant (P=0.199) change on the performance of the G6PD RDT test kit compared to the "gold standard". The outcome of this study suggests that the diagnostic performance of the CareStart G6PD deficiency RDT kit was high and it is acceptable at determining the G6PD deficiency status in a high malaria endemic area in Ghana. The RDT kit presents as an attractive tool for point-of-care G6PD deficiency for rapid testing in areas with high temperatures and less expertise. The CareStart G6PD deficiency RDT kit could be used to screen malaria patients before administration of the fixed dose primaquine with artemisinin-based combination therapy.

  19. Molecular diagnostics for human leptospirosis.

    PubMed

    Waggoner, Jesse J; Pinsky, Benjamin A

    2016-10-01

    The definitive diagnosis of leptospirosis, which results from infection with spirochetes of the genus Leptospira, currently relies on the use of culture, serological testing (microscopic agglutination testing), and molecular detection. The purpose of this review is to describe new molecular diagnostics for Leptospira and discuss advancements in the use of available methods. Efforts have been focused on improving the clinical sensitivity of Leptospira detection using molecular methods. In this review, we describe a reoptimized pathogenic species-specific real-time PCR (targeting lipL32) that has demonstrated improved sensitivity, findings by two groups that real-time reverse-transcription PCR assays targeting the 16S rrs gene can improve detection, and two new loop-mediated amplification techniques. Quantitation of leptospiremia, detection in different specimen types, and the complementary roles played by molecular detection and microscopic agglutination testing will be discussed. Finally, a protocol for Leptospira strain subtyping using variable number tandem repeat targets and high-resolution melting will be described. Molecular diagnostics have an established role for the diagnosis of leptospirosis and provide an actionable diagnosis in the acute setting. The use of real-time reverse-transcription PCR for testing serum/plasma and cerebrospinal fluid, when available, may improve the detection of Leptospira without decreasing clinical specificity.

  20. Instrumentation for noninvasive express-diagnostics bacteriophages and viruses by optical method

    NASA Astrophysics Data System (ADS)

    Moguilnaia, Tatiana A.; Andreev, Gleb I.; Agibalov, Andrey A.; Botikov, Andrey G.; Kosenkov, Evgeniy; Saguitova, Elena

    2004-03-01

    The theoretical and the experimental researches of spectra of absent-minded radiation in medium containing viruses were carried out. The information on spectra luminescence 31 viruses was written down.The new method the express - analysis of viruses in organism of the man was developed. It shall be mentioned that the proposed method of express diagnostics allows detection of infection agent in the organism several hours after infection. It makes it suitable for high efficient testing in blood services for detection and rejection of potential donors infected with such viruses as hepatitis, herpes, Epstein-Barre, cytomegalovirus, and immunodeficiency. Methods of serum diagnostics used for that purpose can detect antibodies to virus only 1-3 months after the person has been infected. The device for the express analysis of 31 viruses of the man was created.

  1. 21 CFR 660.43 - Potency test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 7 2013-04-01 2013-04-01 false Potency test. 660.43 Section 660.43 Food and Drugs... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.43 Potency test... antibody in the appropriate sera of the reference panel by all test methods recommended by the manufacturer...

  2. Detection of scabies: A systematic review of diagnostic methods.

    PubMed

    Leung, Victor; Miller, Mark

    2011-01-01

    Accurate diagnosis of scabies infection is important for patient treatment and for public health control of scabies epidemics. To systematically review the accuracy and precision of history, physical examination and tests for diagnosing scabies. Using a structured search strategy, Medline and Embase databases were searched for English and French language articles that included a diagnosis of scabies. Studies comparing history, physical examination and/or any diagnostic tests with the reference standard of microscopic visualization of mites, eggs or fecal elements obtained from skin scrapings or biopsies were included for analysis. Data were extracted using standard criteria. History and examination of pruritic dermatoses failed to accurately diagnose scabies infection. Dermatoscopy by a trained practitioner has a positive likelihood ratio of 6.5 (95% CI 4.1 to 10.3) and a negative likelihood ratio of 0.1 (95% CI 0.06 to 0.2) for diagnosing scabies. The accuracy of other diagnostic tests could not be calculated from the data in the literature. In the face of such diagnostic inaccuracy, clinical judgment is still practical in diagnosing scabies. Two tests are used - the burrow ink test and handheld dermatoscopy. The burrow ink test is a simple, rapid, noninvasive test that can be used to screen a large number of patients. Handheld dermatoscopy is an accurate test, but requires special equipment and trained practitioners. Given the morbidity and costs of scabies infection, and that studies to date lack adequate internal and external validity, research to identify or develop accurate diagnostic tests for scabies infection is needed and justifiable.

  3. [Assessment of a rapid diagnostic test and portable fluorescent microscopy for malaria diagnosis in Cotonou (Bénin)].

    PubMed

    Ogouyèmi-Hounto, A; Kinde-Gazard, D; Keke, C; Gonçalves, E; Alapini, N; Adjovi, F; Adisso, L; Bossou, C; Denon, Y V; Massougbodji, A

    2013-02-01

    The aim of the study was to determine the accuracy of a rapid diagnostic test (SD Bioline Malaria Ag P.f/ Pan®) and fluorescent microscopy (CyScope®) in confirming presumptive malaria diagnosis in Cotonou. Thick blood smear was used as the reference technique for comparison. Testing was conducted on persons between the ages of 6 months and 70 years at two hospitals from June to October 2010. If malaria was suspected in the sample by the nurse based on clinical findings and sent to laboratory for confirmation, one thick smear, one rapid diagnostic test and one slide for the fluorescent microscopy were performed. All tests were read in hospital laboratories involved with the quality control of thick blood smear in the parasitology laboratory of National University Hospital of Cotonou. A total of 354 patients with clinical diagnosis of malaria were included. Malaria prevalence determined by thick smear, rapid diagnostic test and fluorescent microscopy was 22.8%, 25.4%, and 25.1% respectively. The sensitivity, specificity, positive and negative predictive values compared to the thick smears were 96.3, 95.6, 86.7, and 98.9% for rapid diagnostic test; and 97.5, 96.7, 89.8, and 99.27% for fluorescent microscopy. With these performances, these tests meet acceptability standards recommended by WHO for rapid tests (sensitivity > 95%). These two methods have advantages for the confirmation of malaria diagnosis in peripheral health structures that lack the resources to conduct diagnosis confirmation by the thick blood smear.

  4. Light-scattering analysis of ultrasonic wave's influence on the RBC agglutination in vitro

    NASA Astrophysics Data System (ADS)

    Doubrovski, Valeri A.; Dvoretski, Costanten N.

    1999-04-01

    Elastic light scattering is one of the most often used optical methods to analyze the cells agglutination reaction - the base of a great number of medical diagnostic test and biomedical investigations. The increase of the resolution of methods and apparatus towards the induced cells aggregation - the foundation of the reaction of agglutination, is quite an actual problem. The solution of this problem increases the reliability of the diagnostic test and gives an opportunity to achieve the diagnostic information in the cases when the traditional approaches do not lead to the diagnostic results. The attempt to increase the resolution of the immune reaction analyzer by means of ultrasonic waves action on the reagent mixture in vitro is taken in this paper. The RBC agglutination reaction which is usually used for the blood group type examination is chosen as an example of an object of the investigation. Different laser optical trains of the devices based on the turbidimetric and nephelometric methods and their combination are analyzed here. The influence of the ultrasonic wave time interval action and of the features of the sample preparation procedure on the resolution towards the agglutination process was investigated in this work. It is shown that the ultrasonic wave action on the reagent mixture leads to a large gain in the resolution of the device towards the RBC agglutination process. The experiments showed that the resolution of the device was enough to register the agglutination process even for the erythrocytes with weak agglutination ability when the reaction was invisible without ultrasonic action. It occurred that the diagnostic test time was more than by an order shortened due to the ultrasonic wave action. The optimal ultrasonic time interval action, the sample preparation technology and experimental technique were defined. The principle of the ultrasonic wave action on the cells agglutination process suggested here can be spread out on the immune molecular media. The results may be useful to develop new apparatus and methods for the aims of medical laboratory diagnostics.

  5. Systematic review and meta-analysis: rapid diagnostic tests versus placental histology, microscopy and PCR for malaria in pregnant women

    PubMed Central

    2011-01-01

    Background During pregnancy, malaria infection with Plasmodium falciparum or Plasmodium vivax is related to adverse maternal health and poor birth outcomes. Diagnosis of malaria, during pregnancy, is complicated by the absence or low parasite densities in peripheral blood. Diagnostic methods, other than microscopy, are needed for detection of placental malaria. Therefore, the diagnostic accuracy of rapid diagnostic tests (RDTs), detecting antigen, and molecular techniques (PCR), detecting DNA, for the diagnosis of Plasmodium infections in pregnancy was systematically reviewed. Methods MEDLINE, EMBASE and Web of Science were searched for studies assessing the diagnostic accuracy of RDTs, PCR, microscopy of peripheral and placental blood and placental histology for the detection of malaria infection (all species) in pregnant women. Results The results of 49 studies were analysed in metandi (Stata), of which the majority described P. falciparum infections. Although both placental and peripheral blood microscopy cannot reliably replace histology as a reference standard for placental P. falciparum infection, many studies compared RDTs and PCR to these tests. The proportion of microscopy positives in placental blood (sensitivity) detected by peripheral blood microscopy, RDTs and PCR are respectively 72% [95% CI 62-80], 81% [95% CI 55-93] and 94% [95% CI 86-98]. The proportion of placental blood microscopy negative women that were negative in peripheral blood microscopy, RDTs and PCR (specificity) are 98% [95% CI 95-99], 94% [95% CI 76-99] and 77% [95% CI 71-82]. Based on the current data, it was not possible to determine if the false positives in RDTs and PCR are caused by sequestered parasites in the placenta that are not detected by placental microscopy. Conclusion The findings suggest that RDTs and PCR may have good performance characteristics to serve as alternatives for the diagnosis of malaria in pregnancy, besides any other limitations and practical considerations concerning the use of these tests. Nevertheless, more studies with placental histology as reference test are urgently required to reliably determine the accuracy of RDTs and PCR for the diagnosis of placental malaria. P. vivax-infections have been neglected in diagnostic test accuracy studies of malaria in pregnancy. PMID:22035448

  6. Information engineering for molecular diagnostics.

    PubMed Central

    Sorace, J. M.; Ritondo, M.; Canfield, K.

    1994-01-01

    Clinical laboratories are beginning to apply the recent advances in molecular biology to the testing of patient samples. The emerging field of Molecular Diagnostics will require a new Molecular Diagnostics Laboratory Information System which handles the data types, samples and test methods found in this field. The system must be very flexible in regards to supporting ad-hoc queries. The requirements which are shaping the developments in this field are reviewed and a data model developed. Several queries which demonstrate the data models ability to support the information needs of this area have been developed and run. These results demonstrate the ability of the purposed data model to meet the current and projected needs of this rapidly expanding field. PMID:7949937

  7. Chromosomal Microarray Testing in 42 Korean Patients with Unexplained Developmental Delay, Intellectual Disability, Autism Spectrum Disorders, and Multiple Congenital Anomalies.

    PubMed

    Lee, Sun Ho; Song, Wung Joo

    2017-09-01

    Chromosomal microarray (CMA) is a high-resolution, high-throughput method of identifying submicroscopic genomic copy number variations (CNVs). CMA has been established as the first-line diagnostic test for individuals with developmental delay (DD), intellectual disability (ID), autism spectrum disorders (ASDs), and multiple congenital anomalies (MCAs). CMA analysis was performed in 42 Korean patients who had been diagnosed with unexplained DD, ID, ASDs, and MCAs. Clinically relevant CNVs were discovered in 28 patients. Variants of unknown significance were detected in 13 patients. The diagnostic yield was high (66.7%). CMA is a superior diagnostic tool compared with conventional karyotyping and fluorescent in situ hybridization.

  8. Mycobacterium bovis infections in domesticated non-bovine mammalian species. Part 2: A review of diagnostic methods.

    PubMed

    Broughan, J M; Crawshaw, T R; Downs, S H; Brewer, J; Clifton-Hadley, R S

    2013-11-01

    Despite the large host range of Mycobacterium bovis, ante-mortem diagnostic tests for the infection mostly lack sensitivity/specificity and/or remain unvalidated in non-bovine species. The epidemiology and importance of M. bovis infection in these species are discussed in the first part of this two-part review. This second part focuses on the diagnostic options available to identify infected species such as sheep, goats, dogs, cats, and camelids, and highlights the significant challenges posed, both in establishing estimates of disease prevalence and in controlling infections in these species, in the absence of fully validated tests. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  9. Evaluation of the Diagnostic Accuracy of CareStart G6PD Deficiency Rapid Diagnostic Test (RDT) in a Malaria Endemic Area in Ghana, Africa

    PubMed Central

    Adu-Gyasi, Dennis; Asante, Kwaku Poku; Newton, Sam; Dosoo, David; Amoako, Sabastina; Adjei, George; Amoako, Nicholas; Ankrah, Love; Tchum, Samuel Kofi; Mahama, Emmanuel; Agyemang, Veronica; Kayan, Kingsley; Owusu-Agyei, Seth

    2015-01-01

    Background Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most widespread enzyme defect that can result in red cell breakdown under oxidative stress when exposed to certain medicines including antimalarials. We evaluated the diagnostic accuracy of CareStart G6PD deficiency Rapid Diagnostic Test (RDT) as a point-of-care tool for screening G6PD deficiency. Methods A cross-sectional study was conducted among 206 randomly selected and consented participants from a group with known G6PD deficiency status between February 2013 and June 2013. A maximum of 1.6ml of capillary blood samples were used for G6PD deficiency screening using CareStart G6PD RDT and Trinity qualitative with Trinity quantitative methods as the “gold standard”. Samples were also screened for the presence of malaria parasites. Data entry and analysis were done using Microsoft Access 2010 and Stata Software version 12. Kintampo Health Research Centre Institutional Ethics Committee granted ethical approval. Results The sensitivity (SE) and specificity (SP) of CareStart G6PD deficiency RDT was 100% and 72.1% compared to Trinity quantitative method respectively and was 98.9% and 96.2% compared to Trinity qualitative method. Malaria infection status had no significant (P=0.199) change on the performance of the G6PD RDT test kit compared to the “gold standard”. Conclusions The outcome of this study suggests that the diagnostic performance of the CareStart G6PD deficiency RDT kit was high and it is acceptable at determining the G6PD deficiency status in a high malaria endemic area in Ghana. The RDT kit presents as an attractive tool for point-of-care G6PD deficiency for rapid testing in areas with high temperatures and less expertise. The CareStart G6PD deficiency RDT kit could be used to screen malaria patients before administration of the fixed dose primaquine with artemisinin-based combination therapy. PMID:25885097

  10. Homogeneity tests of clustered diagnostic markers with applications to the BioCycle Study

    PubMed Central

    Tang, Liansheng Larry; Liu, Aiyi; Schisterman, Enrique F.; Zhou, Xiao-Hua; Liu, Catherine Chun-ling

    2014-01-01

    Diagnostic trials often require the use of a homogeneity test among several markers. Such a test may be necessary to determine the power both during the design phase and in the initial analysis stage. However, no formal method is available for the power and sample size calculation when the number of markers is greater than two and marker measurements are clustered in subjects. This article presents two procedures for testing the accuracy among clustered diagnostic markers. The first procedure is a test of homogeneity among continuous markers based on a global null hypothesis of the same accuracy. The result under the alternative provides the explicit distribution for the power and sample size calculation. The second procedure is a simultaneous pairwise comparison test based on weighted areas under the receiver operating characteristic curves. This test is particularly useful if a global difference among markers is found by the homogeneity test. We apply our procedures to the BioCycle Study designed to assess and compare the accuracy of hormone and oxidative stress markers in distinguishing women with ovulatory menstrual cycles from those without. PMID:22733707

  11. Development of a highly sensitive immunochromatographic detection kit for H5 influenza virus hemagglutinin using silver amplification.

    PubMed

    Wada, Atsuhiko; Sakoda, Yoshihiro; Oyamada, Takayoshi; Kida, Hiroshi

    2011-12-01

    H5N1, a highly pathogenic avian influenza virus (HPAIV), has become a serious epizootic threat to the poultry population in Asia. In addition, significant numbers of human cases of HPAIV infection have been reported to date. To prevent the spread of HPAIV among humans and to allow for timely medical intervention, a rapid and high sensitive method is needed to detect and subtype the causative HPAIVs. In the present study, a silver amplification technique used in photographic development was combined with immunochromatography technologies and a highly sensitive and rapid diagnostic test to detect the hemagglutinin of H5 influenza viruses was developed. The sensitivity of the test kit was increased 500 times by silver amplification. The sensitivity of the method was more than 10 times higher than those of conventional rapid influenza diagnostic tests, which detect viral nucleoproteins. The diagnostic system developed in the present study can therefore provide rapid and highly sensitive results and will be useful for diagnosis of H5 HPAIV infection in humans and animals. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Molecular methods for somatic mutation testing in lung adenocarcinoma: EGFR and beyond

    PubMed Central

    Rogers, Toni-Maree; Fellowes, Andrew; Bell, Anthony; Fox, Stephen

    2015-01-01

    Somatic mutational profiling in cancer has revolutionized the practice of clinical oncology. The discovery of driver mutations in non-small cell lung cancer (NSCLC) is an example of this. Molecular testing of lung adenocarcinoma is now considered standard of care and part of the diagnostic algorithm. This article provides an overview of the workflow of molecular testing in a clinical diagnostic laboratory discussing in particular novel assays that are currently in use for somatic mutation detection in NSCLC focussing on epidermal growth factor receptor (EGFR) mutations and anaplastic lymphoma kinase (ALK), ROS1 and RET rearrangements. PMID:25870795

  13. Diagnostic potential of nested PCR, galactomannan EIA, and beta-D-glucan for invasive aspergillosis in pediatric patients.

    PubMed

    Badiee, Parisa; Alborzi, Abdolvahab; Karimi, Mahammad; Pourabbas, Bahman; Haddadi, Pedram; Mardaneh, Jalal; Moieni, Mahsa

    2012-04-13

    Limited specific data and investigations are available for invasive aspergillosis (IA) in pediatric patients. We evaluated the diagnostic potential of three noninvasive tests including the Platelia Aspergillus EIA kit for using galactomannan antigen, (1,3)-β-D-glucan Detection Reagent Kit, and nested-PCR for Aspergillus DNA in sera. We evaluated the diagnostic potential of three noninvasive tests including EIA for galactomannan antigen  (Platelia Aspergillus), nested  PCR assay for Aspergillus DNA and test for (1→3)-β-D-glucan (Glucatell assay Kit). All pediatric patients treated at the hematology/oncology unit who were at increased risk of developing invasive aspergillosis were enrolled. Clinical samples were examined for Aspergillus infections by mycological methods. Serial blood samples were collected twice weekly and evaluated by noninvasive tests. We analyzed 230 consecutive blood samples from 62 pediatric patients. The incidence rate of invasive aspergillosis in the patients was found to be 27.4%, and the etiologic agents were Aspergillus flavus, Aspergillus fumigatus, and Aspergillus spp.  The sensitivity, specificity, positive and negative predictive values, and likelihood ratios for positive and negative results of galactomannan in patients with proven and probable IA were 90%, 92%, 81.8%, 96%, 11.25, and 0.1; for beta-D-glucan they were 50%, 46%, 26%, 70.6%, 0.9, 0.9; and for nested-PCR they were 80%, 96.2%, 88.9%, 92.6%, 21, and 0.2, respectively. The conventional methods are not able to detect IA, due to the lack of valid and proper sampling. Galactomannan and nested-PCR tests in serum, with enough accuracy and reliability, can serve as noninvasive methods for the detection of IA in pediatric patients. However, the beta-D-glucan test cannot serve as an efficient diagnostic tool in those with hematologic disorders. 

  14. Diagnostic performance of a rapid in-clinic test for the detection of Canine Parvovirus under different storage conditions and vaccination status.

    PubMed

    Kantere, Maria C; Athanasiou, Labrini V; Spyrou, Vassiliki; Kyriakis, Constantinos S; Kontos, Vassilios; Chatzopoulos, Dimitrios C; Tsokana, Constantina N; Billinis, Charalambos

    2015-04-01

    Canine parvovirus (CPV) is one of the most common causes of acute haemorrhagic enteritis in young dogs, while clinical diagnosis is often indecisive. The aim of our study was to evaluate the diagnostic accuracy of an in-clinic rapid test in the detection of CPV infection in dogs. To this end, we compared the Rapid Diagnostic Kit of Canine Parvovirus, Coronavirus and Rotavirus antigen (Quicking(®)) to PCR, which is considered as the most reliable diagnostic method. A total of 78 duplicated faecal samples were collected from diarrhoeic dogs. Vaccination history within a month prior to the onset of diarrhoea was reported for 12 of the sampled dogs. The rapid diagnostic test was performed in 23 of the faecal samples directly, while the rest were placed into a sterile cotton tipped swab suitable for collection and transportation of viruses (Sigma Σ-VCM(®)) and stored at -20 °C. The sensitivity of the Quicking rapid diagnostic test compared to PCR in the total number of samples, in samples from non-vaccinated dogs and in samples tested directly after collection were 22.22% (95% CI: 13.27-33.57%), 26.67% (95% CI: 16.08-39.66%) and 76.47% (95% CI: 50.10-93.04%) respectively, while the specificity of the test was 100% in any case. In conclusion, negative results do not exclude parvoenteritis from the differential diagnosis, especially in dogs with early vaccination history, but a positive result almost certainly indicates CPV infection. An improved sensitivity may be expected when the test is performed immediately. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Use of a pLDH-based dipstick in the diagnostic and therapeutic follow-up of malaria patients in Mali

    PubMed Central

    2011-01-01

    Background Malaria is a major public health problem in Mali and diagnosis is typically based on microscopy. Microscopy requires a well trained technician, a reliable power source, a functioning microscope and adequate supplies. The scarcity of resources of community health centres (CHC) does not allow for such a significant investment in only one aspect of malaria control. In this context, Rapid Diagnostic Tests (RDTs) may improve case management particularly in remote areas. Methods This multicentre study included 725 patients simultaneously screened with OptiMal-IT test and thick smears for malaria parasite detection. While evaluating the therapeutic efficacy of choroquine in 2 study sites, we compared the diagnostic values of thick smear microscopy to OptiMal-IT test applying the WHO 14 days follow-up scheme using samples collected from 344 patients. Results The sensitivity and the specificity of OptiMal-IT compared to thick smear was 97.2% and 95.4%, whereas the positive and negative predictive values were 96.7 and 96.1%, respectively. The percent agreement between the two diagnostic tests was 0.93. The two tests were comparable in detecting malaria at day 0, day 3 and day 14. The only difference was observed at day 7 due to high gametocytemia. Subjectively, health care providers found OptiMal-IT easier to use and store under field conditions. Conclusion OptiMal-IT test revealed similar results when compared to microscopy which is considered the gold standard for malaria diagnostics. The test was found to have a short processing time and was easier to use. These advantages may improve malaria case management by providing a diagnostic and drug efficacy follow-up tool to peripheral health centres with limited resources. PMID:22114867

  16. Progress towards implementation of ACT malaria case-management in public health facilities in the Republic of Sudan: a cluster-sample survey

    PubMed Central

    2012-01-01

    Background Effective malaria case-management based on artemisinin-based combination therapy (ACT) and parasitological diagnosis is a major pillar within the 2007-2012 National Malaria Strategic Plan in the Sudan. Three years after the launch of the strategy a health facility survey was undertaken to evaluate case-management practices and readiness of the health facilities and health workers to implement a new malaria case-management strategy. Methods A cross-sectional, cluster sample survey was undertaken at public health facilities in 15 states of Sudan. Data were collected using quality-of-care assessment methods. The main outcomes were the proportions of facilities with ACTs and malaria diagnostics; proportions of health workers exposed to malaria related health systems support activities; and composite and individual indicators of case-management practices for febrile outpatients stratified by age, availability of ACTs and diagnostics, use of malaria diagnostics, and test result. Results We evaluated 244 facilities, 294 health workers and 1,643 consultations for febrile outpatients (425 < 5 years and 1,218 ≥ 5 years). Health facility and health worker readiness was variable: chloroquine was available at only 5% of facilities, 73% stocked recommended artesunate and sulfadoxine/pyrimethamine (AS+SP), 51% had the capacity to perform parasitological diagnosis, 53% of health workers had received in-service training on ACTs, 24% were trained in the use of malaria Rapid Diagnostic Tests, and 19% had received a supervisory visit including malaria case-management. At all health facilities 46% of febrile patients were parasitologically tested and 35% of patients were both, tested and treated according to test result. At facilities where AS+SP and malaria diagnostics were available 66% of febrile patients were tested and 51% were both, tested and treated according to test result. Among test positive patients 64% were treated with AS+SP but 24% were treated with artemether monotherapy. Among test negative patients only 17% of patients were treated for malaria. The majority of ACT dispensing and counseling practices were suboptimal. Conclusions Five years following change of the policy from chloroquine to ACTs and 3 years before the end of the new malaria strategic plan chloroquine was successfully phased out from public facilities in Sudan, however, an important gap remained in the availability of ACTs, diagnostic capacities and coverage with malaria case-management activities. The national scale-up of diagnostics, using the findings of this survey as well as future qualitative research, should present an opportunity not only to expand existing testing capacities but also to implement effective support interventions to bridge the health systems gaps and support corrective case-management measures, including the discontinuation of artemether monotherapy treatment. PMID:22221821

  17. Diagnostic yield of endobronchial ultrasound-guided transbronchial needle aspiration for mediastinal staging in lung cancer*

    PubMed Central

    Fernández-Bussy, Sebastián; Labarca, Gonzalo; Canals, Sofia; Caviedes, Iván; Folch, Erik; Majid, Adnan

    2015-01-01

    OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic test with a high diagnostic yield for suspicious central pulmonary lesions and for mediastinal lymph node staging. The main objective of this study was to describe the diagnostic yield of EBUS-TBNA for mediastinal lymph node staging in patients with suspected lung cancer. METHODS: Prospective study of patients undergoing EBUS-TBNA for diagnosis. Patients ≥ 18 years of age were recruited between July of 2010 and August of 2013. We recorded demographic variables, radiological characteristics provided by axial CT of the chest, location of the lesion in the mediastinum as per the International Association for the Study of Lung Cancer classification, and definitive diagnostic result (EBUS with a diagnostic biopsy or a definitive diagnostic method). RESULTS: Our analysis included 354 biopsies, from 145 patients. Of those 145 patients, 54.48% were male. The mean age was 63.75 years. The mean lymph node size was 15.03 mm, and 90 lymph nodes were smaller than 10.0 mm. The EBUS-TBNA method showed a sensitivity of 91.17%, a specificity of 100.0%, and a negative predictive value of 92.9%. The most common histological diagnosis was adenocarcinoma. CONCLUSIONS: EBUS-TBNA is a diagnostic tool that yields satisfactory results in the staging of neoplastic mediastinal lesions. PMID:26176519

  18. Clinical neurophysiology and quantitative sensory testing in the investigation of orofacial pain and sensory function.

    PubMed

    Jääskeläinen, Satu K

    2004-01-01

    Chronic orofacial pain represents a diagnostic and treatment challenge for the clinician. Some conditions, such as atypical facial pain, still lack proper diagnostic criteria, and their etiology is not known. The recent development of neurophysiological methods and quantitative sensory testing for the examination of the trigeminal somatosensory system offers several tools for diagnostic and etiological investigation of orofacial pain. This review presents some of these techniques and the results of their application in studies on orofacial pain and sensory dysfunction. Clinical neurophysiological investigation has greater diagnostic accuracy and sensitivity than clinical examination in the detection of the neurogenic abnormalities of either peripheral or central origin that may underlie symptoms of orofacial pain and sensory dysfunction. Neurophysiological testing may also reveal trigeminal pathology when magnetic resonance imaging has failed to detect it, so these methods should be considered complementary to each other in the investigation of orofacial pain patients. The blink reflex, corneal reflex, jaw jerk, sensory neurography of the inferior alveolar nerve, and the recording of trigeminal somatosensory-evoked potentials with near-nerve stimulation have all proved to be sensitive and reliable in the detection of dysfunction of the myelinated sensory fibers of the trigeminal nerve or its central connections within the brainstem. With appropriately small thermodes, thermal quantitative sensory testing is useful for the detection of trigeminal small-fiber dysfunction (Adelta and C). In neuropathic conditions, it is most sensitive to lesions causing axonal injury. By combining different techniques for investigation of the trigeminal system, an accurate topographical diagnosis and profile of sensory fiber pathology can be determined. Neurophysiological and quantitative sensory tests have already highlighted some similarities among various orofacial pain conditions and have shown heterogeneity within clinical diagnostic categories. With the aid of neurophysiological recordings and quantitative sensory testing, it is possible to approach a mechanism-based classification of orofacial pain.

  19. Review: Diagnostic accuracy of PCR-based detection tests for Helicobacter Pylori in stool samples.

    PubMed

    Khadangi, Fatemeh; Yassi, Maryam; Kerachian, Mohammad Amin

    2017-12-01

    Although different methods have been established to detect Helicobacter pylori (H. pylori) infection, identifying infected patients is an ongoing challenge. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for stool PCR test in the diagnosis of H. pylori infection. In this study, a systematic review and meta-analysis were carried out on various sources, including MEDLINE, Web of Sciences, and the Cochrane Library from April 1, 1999, to May 1, 2016. This meta-analysis adheres to the guidelines provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses report (PRISMA Statement). The clinical value of DNA stool PCR test was based on the pooled false positive, false negative, true positive, and true negative of different genes. Twenty-six of 328 studies identified met the eligibility criteria. Stool PCR test had a performance of 71% (95% CI: 68-73) sensitivity, 96% (95% CI: 94-97) specificity, and 65.6 (95% CI: 30.2-142.5) diagnostic odds ratio (DOR) in diagnosis of H. pylori. The DOR of genes which showed the highest performance of stool PCR tests was as follows: 23S rRNA 152.5 (95% CI: 55.5-418.9), 16S rRNA 67.9 (95%CI: 6.4-714.3), and glmM 68.1 (95%CI: 20.1-231.7). The sensitivity and specificity of stool PCR test are relatively in the same spectrum of other diagnostic methods for the detection of H. pylori infection. In descending order of significance, the most diagnostic candidate genes using PCR detection were 23S rRNA, 16S rRNA, and glmM. PCR for 23S rRNA gene which has the highest performance could be applicable to detect H. pylori infection. © 2017 John Wiley & Sons Ltd.

  20. Clinical Laboratories – Production Factories or Specialized Diagnostic Centers

    PubMed Central

    Tóth, Judit

    2016-01-01

    Since a large proportion of medical decisions are based on laboratory results, clinical laboratories should meet the increasing demand of clinicians and their patients. Huge central laboratories may process over 10 million tests annually; they act as production factories, measuring emergency and routine tests with sufficient speed and accuracy. At the same time, they also serve as specialized diagnostic centers where well-trained experts analyze and interpret special test results. It is essential to improve and constantly monitor this complex laboratory service, by several methods. Sample transport by pneumatic tube system, use of an advanced laboratory information system and point-of-care testing may result in decreased total turnaround time. The optimization of test ordering may result in a faster and more cost-effective laboratory service. Autovalidation can save time for laboratory specialists, when the analysis of more complex results requires their attention. Small teams of experts responsible for special diagnostic work, and their interpretative reporting according to predetermined principles, may help to minimize subjectivity of these special reports. Although laboratory investigations have become so diversely developed in the past decades, it is essential that the laboratory can provide accurate results relatively quickly, and that laboratory specialists can support the diagnosis and monitoring of patients by adequate interpretation of esoteric laboratory methods. PMID:27683528

  1. Aminopenicillin-associated exanthem: lymphocyte transformation testing revisited.

    PubMed

    Trautmann, A; Seitz, C S; Stoevesandt, J; Kerstan, A

    2014-12-01

    The lymphocyte transformation test (LTT) has been promoted as in-vitro test for diagnosis of drug hypersensitivity. For determination of statistical LTT sensitivity, series of patients with clinically uniform reactions followed by complete drug hypersensitivity work-up are mandatory. Assessment of LTT specificity requires control patients who tolerated exposure to the drug studied. To prospectively determine the diagnostic value of the LTT in a clinically and diagnostically well-defined series of patients. Patients with exanthematous skin eruptions after ampicillin (AMP) intake were included in this study. After exclusion or confirmation of delayed-onset allergic AMP hypersensitivity by skin and provocation testing, two independent LTTs were performed: one standard LTT and a modified LTT with additional anti-CD3/anti-CD28 monoclonal antibody stimulation. By testing, delayed-onset allergic AMP hypersensitivity was diagnosed in 11 patients and definitely ruled out in 26. The standard LTT reached a diagnostic sensitivity of 54.5% while the modified LTT yielded 72.7%. However, the methodical test modification resulted in a decline of specificity from 92.3% (standard LTT) to 76.9%. In cases of AMP-associated exanthems, the diagnostic value of the LTT compared with routine allergy testing is limited. When evaluating such exanthems, provocation testing remains the gold standard. Delayed reading of intradermal skin tests remains most useful to avoid positive provocation reactions. © 2014 John Wiley & Sons Ltd.

  2. Residual gas analyzer mass spectrometry for human breath analysis: a new tool for the non-invasive diagnosis of Helicobacter pylori infection.

    PubMed

    Maity, Abhijit; Banik, Gourab D; Ghosh, Chiranjit; Som, Suman; Chaudhuri, Sujit; Daschakraborty, Sunil B; Ghosh, Shibendu; Ghosh, Barnali; Raychaudhuri, Arup K; Pradhan, Manik

    2014-03-01

    A residual gas analyzer (RGA) coupled with a high vacuum chamber is described for the non-invasive diagnosis of the Helicobacter pylori (H. pylori) infection through ¹³C-urea breath analysis. The present RGA-based mass spectrometry (MS) method is capable of measuring high-precision ¹³CO₂ isotope enrichments in exhaled breath samples from individuals harboring the H. pylori infection. The system exhibited 100% diagnostic sensitivity, and 93% specificity alongside positive and negative predictive values of 95% and 100%, respectively, compared with invasive endoscopy-based biopsy tests. A statistically sound diagnostic cut-off value for the presence of H. pylori was determined to be 3.0‰ using a receiver operating characteristic curve analysis. The diagnostic accuracy and validity of the results are also supported by optical off-axis integrated cavity output spectroscopy measurements. The δ¹³(DOB)C‰ values of both methods correlated well (R² = 0.9973 at 30 min). The RGA-based instrumental setup described here is simple, robust, easy-to-use and more portable and cost-effective compared to all other currently available detection methods, thus making it a new point-of-care medical diagnostic tool for the purpose of large-scale screening of the H. pylori infection in real time. The RGA-MS technique should have broad applicability for ¹³C-breath tests in a wide range of biomedical research and clinical diagnostics for many other diseases and metabolic disorders.

  3. Protocol investigating the clinical utility of an objective measure of activity and attention (QbTest) on diagnostic and treatment decision-making in children and young people with ADHD—‘Assessing QbTest Utility in ADHD’ (AQUA): a randomised controlled trial

    PubMed Central

    Hall, Charlotte L; Walker, Gemma M; Valentine, Althea Z; Guo, Boliang; Kaylor-Hughes, Catherine; James, Marilyn; Daley, David; Sayal, Kapil; Hollis, Chris

    2014-01-01

    Introduction The National Institute for Health and Care Excellence (NICE) guidelines for attention deficit/hyperactivity disorder (ADHD) state that young people need to have access to the best evidence-based care to improve outcome. The current ‘gold standard’ ADHD diagnostic assessment combines clinical observation with subjective parent, teacher and self-reports. In routine practice, reports from multiple informants may be unavailable or contradictory, leading to diagnostic uncertainty and delay. The addition of objective tests of attention and activity may help reduce diagnostic uncertainty and delays in initiating treatment leading to improved outcomes. This trial investigates whether providing clinicians with an objective report of levels of attention, impulsivity and activity can lead to an earlier, and more accurate, clinical diagnosis and improved patient outcome. Methods and analysis This multisite randomised controlled trial will recruit young people (aged 6–17 years old) who have been referred for an ADHD diagnostic assessment at Child and Adolescent Mental Health Services (CAMHS) and Community Paediatric clinics across England. Routine clinical assessment will be augmented by the QbTest, incorporating a continuous performance test (CPT) and infrared motion tracking of activity. The participant will be randomised into one of two study arms: QbOpen (clinician has immediate access to a QbTest report): QbBlind (report is withheld until the study end). Primary outcomes are time to diagnosis and diagnostic accuracy. Secondary outcomes include clinician's diagnostic confidence and routine clinical outcome measures. Cost-effective analysis will be conducted, alongside a qualitative assessment of the feasibility and acceptability of incorporating QbTest in routine practice. Ethics and dissemination The findings from the study will inform commissioners, clinicians and managers about the feasibility, acceptability, clinical utility and cost-effectiveness of incorporating QbTest into routine diagnostic assessment of young people with ADHD. The results will be submitted for publication in peer-reviewed journals. The study has received ethical approval. Trial registration number NCT02209116. PMID:25448628

  4. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    PubMed

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  5. Statistical analysis and interpretation of prenatal diagnostic imaging studies, Part 2: descriptive and inferential statistical methods.

    PubMed

    Tuuli, Methodius G; Odibo, Anthony O

    2011-08-01

    The objective of this article is to discuss the rationale for common statistical tests used for the analysis and interpretation of prenatal diagnostic imaging studies. Examples from the literature are used to illustrate descriptive and inferential statistics. The uses and limitations of linear and logistic regression analyses are discussed in detail.

  6. Company Profile: Selventa, Inc.

    PubMed

    Fryburg, David A; Latino, Louis J; Tagliamonte, John; Kenney, Renee D; Song, Diane H; Levine, Arnold J; de Graaf, David

    2012-08-01

    Selventa, Inc. (MA, USA) is a biomarker discovery company that enables personalized healthcare. Originally founded as Genstruct, Inc., Selventa has undergone significant evolution from a technology-based service provider to an active partner in the development of diagnostic tests, functioning as a molecular dashboard of disease activity using a unique platform. As part of that evolution, approximately 2 years ago the company was rebranded as Selventa to reflect its new identity and mission. The contributions to biomedical research by Selventa are based on in silico, reverse-engineering methods to determine biological causality. That is, given a set of in vitro or in vivo biological observations, which biological mechanisms can explain the measured results? Facilitated by a large and carefully curated knowledge base, these in silico methods generated new insights into the mechanisms driving a disease. As Selventa's methods would enable biomarker discovery and be directly applicable to generating novel diagnostics, the scientists at Selventa have focused on the development of predictive biomarkers of response in autoimmune and oncologic diseases. Selventa is presently building a portfolio of independent, as well as partnered, biomarker projects with the intention to create diagnostic tests that predict response to therapy.

  7. Parasite detection in patients with post kala-azar dermal leishmaniasis in India: a comparison between molecular and immunological methods

    PubMed Central

    Salotra, P; Sreenivas, G; Beena, K R; Mukherjee, A; Ramesh, V

    2003-01-01

    Aims: To evaluate the sensitivity and specificity of serological, immunohistochemical, and molecular methods in the diagnosis of post kala-azar dermal leishmaniasis (PKDL). Methods: Twenty five patients with confirmed PKDL and 25 controls were included in the study. G2D10, a monoclonal antibody against Leishmania, was used for the immunohistochemical (IHC) staining of lesion sections to visualise anti-Leishmania donovani antibodies. The diagnostic usefulness of IHC was compared with enzyme linked immunosorbent assay (ELISA) with a recombinant (rk39) antigen, and a species specific polymerase chain reaction (PCR) assay, amplifying a kinetoplast minicircle DNA sequence. Results: IHC detected 22 of 25 PKDL cases, giving a sensitivity of 88%. The diagnostic sensitivity of both the ELISA and PCR tests was higher (96%). All of the 25 controls examined were negative in PCR, indicating 100% specificity of the test, whereas ELISA showed 96% specificity. Conclusions: IHC with G2D10 significantly enhances the sensitivity of detection of PKDL over routine haematoxylin and eosin staining. ELISA with a recombinant antigen is an economical and practical assay. PCR is the most sensitive and specific diagnostic method for PKDL. The tests described would facilitate the recognition of patients with PKDL, enabling timely treatment, which would contribute greatly to the control of kala-azar. PMID:14600129

  8. Decision support in psychiatry – a comparison between the diagnostic outcomes using a computerized decision support system versus manual diagnosis

    PubMed Central

    Bergman, Lars G; Fors, Uno GH

    2008-01-01

    Background Correct diagnosis in psychiatry may be improved by novel diagnostic procedures. Computerized Decision Support Systems (CDSS) are suggested to be able to improve diagnostic procedures, but some studies indicate possible problems. Therefore, it could be important to investigate CDSS systems with regard to their feasibility to improve diagnostic procedures as well as to save time. Methods This study was undertaken to compare the traditional 'paper and pencil' diagnostic method SCID1 with the computer-aided diagnostic system CB-SCID1 to ascertain processing time and accuracy of diagnoses suggested. 63 clinicians volunteered to participate in the study and to solve two paper-based cases using either a CDSS or manually. Results No major difference between paper and pencil and computer-supported diagnosis was found. Where a difference was found it was in favour of paper and pencil. For example, a significantly shorter time was found for paper and pencil for the difficult case, as compared to computer support. A significantly higher number of correct diagnoses were found in the diffilt case for the diagnosis 'Depression' using the paper and pencil method. Although a majority of the clinicians found the computer method supportive and easy to use, it took a longer time and yielded fewer correct diagnoses than with paper and pencil. Conclusion This study could not detect any major difference in diagnostic outcome between traditional paper and pencil methods and computer support for psychiatric diagnosis. Where there were significant differences, traditional paper and pencil methods were better than the tested CDSS and thus we conclude that CDSS for diagnostic procedures may interfere with diagnosis accuracy. A limitation was that most clinicians had not previously used the CDSS system under study. The results of this study, however, confirm that CDSS development for diagnostic purposes in psychiatry has much to deal with before it can be used for routine clinical purposes. PMID:18261222

  9. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial

    PubMed Central

    Di Santo, Pietro; Harnett, David T.; Simard, Trevor; Ramirez, F. Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G.; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong

    2018-01-01

    BACKGROUND: Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. METHODS: We compared the modified Allen test with a smartphone heart rate–monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient’s index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate–monitoring application. RESULTS: Among 438 patients who were included in the study, we found that the heart rate–monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). INTERPRETATION: A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient’s bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. PMID:29615421

  10. Diagnostic reasoning by hospital pharmacists: assessment of attitudes, knowledge, and skills.

    PubMed

    Chernushkin, Kseniya; Loewen, Peter; de Lemos, Jane; Aulakh, Amneet; Jung, Joanne; Dahri, Karen

    2012-07-01

    Hospital pharmacists participate in activities that may be considered diagnostic. Two reasoning approaches to diagnosis have been described: non-analytic and analytic. Of the 6 analytic traditions, the probabilistic tradition has been shown to improve diagnostic accuracy and reduce unnecessary testing. To the authors' knowledge, pharmacists' attitudes toward having a diagnostic role and their diagnostic knowledge and skills have never been studied. To describe pharmacists' attitudes toward the role of diagnosis in pharmacotherapeutic problem-solving and to characterize the extent of pharmacists' knowledge and skills related to diagnostic literacy. Pharmacists working within Lower Mainland Pharmacy Services (British Columbia) who spent at least 33% of their time in direct patient care were invited to participate in a prospective observational survey. The survey sought information about demographic characteristics and attitudes toward diagnosis. Diagnostic knowledge and skills were tested by means of 3 case scenarios. The analysis included simple descriptive statistics and inferential statistics to evaluate relationships between responses and experience and training. Of 266 pharmacists invited to participate, 94 responded. The attitudes section of the survey was completed by 90 pharmacists; of these, 80 (89%) agreed with the definition of "diagnosis" proposed in the survey, and 83 (92%) agreed that it is important for pharmacists to have diagnosis-related skills. Respondents preferred an analytic to a non-analytic approach to diagnostic decision-making. The probabilistic tradition was not the preferred method in any of the 3 cases. In evaluating 5 clinical scenarios that might require diagnostic skills, on average 84% of respondents agreed that they should be involved in assessing such problems. Respondents' knowledge of and ability to apply probabilistic diagnostic tools were highest for test sensitivity (average of 61% of respondents with the correct answers) and lower for test specificity (average of 48% with correct answers) and likelihood ratios (average of 39% with correct answers). Respondents to this survey strongly believed that diagnostic skills were important for solving drug-related problems, but they demonstrated low levels of knowledge and ability to apply concepts of probabilistic diagnostic reasoning. Opportunities to expand pharmacists' knowledge of diagnostic reasoning exist, and the findings reported here indicate that pharmacists would consider such professional development valuable.

  11. Development and assessment of molecular diagnostic tests for 15 enteropathogens causing childhood diarrhoea: a multicentre study.

    PubMed

    Liu, Jie; Kabir, Furqan; Manneh, Jainaba; Lertsethtakarn, Paphavee; Begum, Sharmin; Gratz, Jean; Becker, Steve M; Operario, Darwin J; Taniuchi, Mami; Janaki, Lalitha; Platts-Mills, James A; Haverstick, Doris M; Kabir, Mamun; Sobuz, Shihab U; Nakjarung, Kaewkanya; Sakpaisal, Pimmada; Silapong, Sasikorn; Bodhidatta, Ladaporn; Qureshi, Shahida; Kalam, Adil; Saidi, Queen; Swai, Ndealilia; Mujaga, Buliga; Maro, Athanasia; Kwambana, Brenda; Dione, Michel; Antonio, Martin; Kibiki, Gibson; Mason, Carl J; Haque, Rashidul; Iqbal, Najeeha; Zaidi, Anita K M; Houpt, Eric R

    2014-08-01

    Childhood diarrhoea can be caused by many pathogens that are difficult to assay in the laboratory. Molecular diagnostic techniques provide a uniform method to detect and quantify candidate enteropathogens. We aimed to develop and assess molecular tests for identification of enteropathogens and their association with disease. We developed and assessed molecular diagnostic tests for 15 enteropathogens across three platforms-PCR-Luminex, multiplex real-time PCR, and TaqMan array card-at five laboratories worldwide. We judged the analytical and clinical performance of these molecular techniques against comparator methods (bacterial culture, ELISA, and PCR) using 867 diarrhoeal and 619 non-diarrhoeal stool specimens. We also measured molecular quantities of pathogens to predict the association with diarrhoea, by univariate logistic regression analysis. The molecular tests showed very good analytical and clinical performance at all five laboratories. Comparator methods had limited sensitivity compared with the molecular techniques (20-85% depending on the target) but good specificity (median 97·3%, IQR 96·5-98·9; mean 95·2%, SD 9·1). Positive samples by comparator methods usually had higher molecular quantities of pathogens than did negative samples, across almost all platforms and for most pathogens (p<0·05). The odds ratio for diarrhoea at a given quantity (measured by quantification cycle, Cq) showed that for most pathogens associated with diarrhoea-including Campylobacter jejuni and Campylobacter coli, Cryptosporidium spp, enteropathogenic Escherichia coli, heat-stable enterotoxigenic E coli, rotavirus, Shigella spp and enteroinvasive E coli, and Vibrio cholerae-the strength of association with diarrhoea increased at higher pathogen loads. For example, Shigella spp at a Cq range of 15-20 had an odds ratio of 8·0 (p<0·0001), but at a Cq range of 25-30 the odds ratio fell to 1·7 (p=0·043). Molecular diagnostic tests can be implemented successfully and with fidelity across laboratories around the world. In the case of diarrhoea, these techniques can detect pathogens with high sensitivity and ascribe diarrhoeal associations based on quantification, including in mixed infections, providing rich and unprecedented measurements of infectious causes. Bill & Melinda Gates Foundation Next Generation Molecular Diagnostics Project. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Precision medicine for cancer with next-generation functional diagnostics.

    PubMed

    Friedman, Adam A; Letai, Anthony; Fisher, David E; Flaherty, Keith T

    2015-12-01

    Precision medicine is about matching the right drugs to the right patients. Although this approach is technology agnostic, in cancer there is a tendency to make precision medicine synonymous with genomics. However, genome-based cancer therapeutic matching is limited by incomplete biological understanding of the relationship between phenotype and cancer genotype. This limitation can be addressed by functional testing of live patient tumour cells exposed to potential therapies. Recently, several 'next-generation' functional diagnostic technologies have been reported, including novel methods for tumour manipulation, molecularly precise assays of tumour responses and device-based in situ approaches; these address the limitations of the older generation of chemosensitivity tests. The promise of these new technologies suggests a future diagnostic strategy that integrates functional testing with next-generation sequencing and immunoprofiling to precisely match combination therapies to individual cancer patients.

  13. Quantitative polymerase chain reaction (PCR) for detection of aquatic animal pathogens in a diagnostic laboratory setting

    USGS Publications Warehouse

    Purcell, Maureen K.; Getchell, Rodman G.; McClure, Carol A.; Weber, S.E.; Garver, Kyle A.

    2011-01-01

    Real-time, or quantitative, polymerase chain reaction (qPCR) is quickly supplanting other molecular methods for detecting the nucleic acids of human and other animal pathogens owing to the speed and robustness of the technology. As the aquatic animal health community moves toward implementing national diagnostic testing schemes, it will need to evaluate how qPCR technology should be employed. This review outlines the basic principles of qPCR technology, considerations for assay development, standards and controls, assay performance, diagnostic validation, implementation in the diagnostic laboratory, and quality assurance and control measures. These factors are fundamental for ensuring the validity of qPCR assay results obtained in the diagnostic laboratory setting.

  14. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  15. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Procedural Terminology published by the American Medical Association. (vii) Diagnostic tests performed by a... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  16. Development and validation of a highly sensitive urine-based test to identify patients with colonic adenomatous polyps.

    PubMed

    Wang, Haili; Tso, Victor; Wong, Clarence; Sadowski, Dan; Fedorak, Richard N

    2014-03-20

    Adenomatous polyps are precursors of colorectal cancer; their detection and removal is the goal of colon cancer screening programs. However, fecal-based methods identify patients with adenomatous polyps with low levels of sensitivity. The aim or this study was to develop a highly accurate, prototypic, proof-of-concept, spot urine-based diagnostic test using metabolomic technology to distinguish persons with adenomatous polyps from those without polyps. Prospective urine and stool samples were collected from 876 participants undergoing colonoscopy examination in a colon cancer screening program, from April 2008 to October 2009 at the University of Alberta. Colonoscopy reference standard identified 633 participants with no colonic polyps and 243 with colonic adenomatous polyps. One-dimensional nuclear magnetic resonance spectra of urine metabolites were analyzed to define a diagnostic metabolomic profile for colonic adenomas. A urine metabolomic diagnostic test for colonic adenomatous polyps was established using 67% of the samples (un-blinded training set) and validated using the other 33% of the samples (blinded testing set). The urine metabolomic diagnostic test's specificity and sensitivity were compared with those of fecal-based tests. Using a two-component, orthogonal, partial least-squares model of the metabolomic profile, the un-blinded training set identified patients with colonic adenomatous polyps with 88.9% sensitivity and 50.2% specificity. Validation using the blinded testing set confirmed sensitivity and specificity values of 82.7% and 51.2%, respectively. Sensitivities of fecal-based tests to identify colonic adenomas ranged from 2.5 to 11.9%. We describe a proof-of-concept spot urine-based metabolomic diagnostic test that identifies patients with colonic adenomatous polyps with a greater level of sensitivity (83%) than fecal-based tests.

  17. Acoustic radiation force impulse elastography, FibroScan®, Forns’ index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods

    PubMed Central

    DONG, DAO-RAN; HAO, MEI-NA; LI, CHENG; PENG, ZE; LIU, XIA; WANG, GUI-PING; MA, AN-LIN

    2015-01-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns’ index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty-one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal-Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal-Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=−0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of these methods. PMID:25651500

  18. Acoustic radiation force impulse elastography, FibroScan®, Forns' index and their combination in the assessment of liver fibrosis in patients with chronic hepatitis B, and the impact of inflammatory activity and steatosis on these diagnostic methods.

    PubMed

    Dong, Dao-Ran; Hao, Mei-Na; Li, Cheng; Peng, Ze; Liu, Xia; Wang, Gui-Ping; Ma, An-Lin

    2015-06-01

    The aim of the present study was to investigate the combination of certain serological markers (Forns' index; FI), FibroScan® and acoustic radiation force impulse elastography (ARFI) in the assessment of liver fibrosis in patients with hepatitis B, and to explore the impact of inflammatory activity and steatosis on the accuracy of these diagnostic methods. Eighty‑one patients who had been diagnosed with hepatitis B were recruited and the stage of fibrosis was determined by biopsy. The diagnostic accuracy of FI, FibroScan and ARFI, as well as that of the combination of these methods, was evaluated based on the conformity of the results from these tests with those of biopsies. The effect of concomitant inflammation on diagnostic accuracy was also investigated by dividing the patients into two groups based on the grade of inflammation (G<2 and G≥2). The overall univariate correlation between steatosis and the diagnostic value of the three methods was also evaluated. There was a significant association between the stage of fibrosis and the results obtained using ARFI and FibroScan (Kruskal‑Wallis; P<0.001 for all patients), and FI (t-test, P<0.001 for all patients). The combination of FI with ARFI/FibroScan increased the predictive accuracy with a fibrosis stage of S≥2 or cirrhosis. There was a significant correlation between the grade of inflammation and the results obtained using ARFI and FibroScan (Kruskal‑Wallis, P<0.001 for all patients), and FI (t-test; P<0.001 for all patients). No significant correlation was detected between the measurements obtained using ARFI, FibroScan and FI, and steatosis (r=‑0.100, P=0.407; r=0.170, P=0.163; and r=0.154, P=0.216, respectively). ARFI was shown to be as effective in the diagnosis of liver fibrosis as FibroScan or FI, and the combination of ARFI or FibroScan with FI may improve the accuracy of diagnosis. The presence of inflammatory activity, but not that of steatosis, may affect the diagnostic accuracy of these methods.

  19. [A new system of testing visual performance based on the cylindrical lens screen].

    PubMed

    Doege, E; Krause, O

    1983-09-01

    Using a special microoptical screen as a test-picture coating, a method for testing binocular function was developed. It offers the advantage of providing a separate visual impression to each eye from a diagnostic picture without using any device in front of the eyes. The person tested is unaware of this procedure, of which the diagnostic plate gives no hint. In addition to a description of its numerous uses and diagnostic possibilities, fusion pictures suitable for screening tests are described: Each eye is offered a separate impression with a completely different content. If fusion occurs correctly, a third motif with an entirely new meaning emerges. Several years of experience with this effective system (naked-eye tests) resulted in aids which are listed in the final section of the paper: exercise aids used for preparing the persons tested (especially infants) in the waiting room, recognition aids for the examination, and a partially kinetic picture for rapid, simple and very convincing representation of adjusting movements and of the squint position in cases of concomitant squint.

  20. Validation of caffeine dehydrogenase from Pseudomonas sp. strain CBB1 as a suitable enzyme for a rapid caffeine detection and potential diagnostic test.

    PubMed

    Mohanty, Sujit K; Yu, Chi Li; Gopishetty, Sridhar; Subramanian, Mani

    2014-08-06

    Excess consumption of caffeine (>400 mg/day/adult) can lead to adverse health effects. Recent introduction of caffeinated products (gums, jelly beans, energy drinks) might lead to excessive consumption, especially among children and nursing mothers, hence attracting the Food and Drug Administration's attention and product withdrawals. An "in-home" test will aid vigilant consumers in detecting caffeine in beverages and milk easily and quickly, thereby restricting its consumption. Known diagnostic methods lack speed and sensitivity. We report a caffeine dehydrogenase (Cdh)-based test which is highly sensitive (1-5 ppm) and detects caffeine in beverages and mother's milk in 1 min. Other components in these complex test samples do not interfere with the detection. Caffeine-dependent reduction of the dye iodonitrotetrazolium chloride results in shades of pink proportional to the levels in test samples. This test also estimates caffeine levels in pharmaceuticals, comparable to high-performance liquid chromatography. The Cdh-based test is the first with the desired attributes of a rapid and robust caffeine diagnostic kit.

  1. Single-centre study of the diagnostic performance of plasma metanephrines with seated sampling for the diagnosis of phaeochromocytoma/paraganglioma.

    PubMed

    Boot, Christopher; Toole, Barry; Johnson, Sarah J; Ball, Stephen; Neely, Dermot

    2017-01-01

    Background Measurement of plasma metanephrines is regarded as one of the best screening tests for phaeochromocytoma/paraganglioma. Current guidelines recommend that samples are ideally collected in the supine position after 30 min rest and interpreted using supine reference ranges, in order to optimize the diagnostic performance of the test. Current practice in our centre is to collect samples for plasma metanephrines from seated patients. The aim of the study was to determine, if seated sampling for plasma metanephrines provides acceptable diagnostic performance in our centre. Methods Clinical and laboratory data of 113 patients, gathered over a four-year period 2010-2014, were reviewed. All had undergone preoperative plasma metanephrines measurement and had postoperative histopathology confirmation or exclusion of phaeochromocytoma/paraganglioma. Results Of 113 patients included in the study, 40 had a histological diagnosis of phaeochromocytoma/paraganglioma. The remaining 73 patients had an alternative adrenal pathology. The diagnostic sensitivity of normetanephrine or metanephrine above the upper limit of our in-house seated reference range was 93%. However, excluding three cases of paraganglioma determined clinically and biochemically to be non-functional raised the sensitivity to 100%. Diagnostic specificity was 90%. Applying published supine reference ranges made no difference to diagnostic sensitivity in this group of patients but decreased diagnostic specificity to 75%. Conclusions While these data are derived from a relatively small study population, they demonstrate acceptable diagnostic performance for seated plasma metanephrines as a screening test for phaeochromocytoma/paraganglioma. These data highlight a high diagnostic sensitivity for plasma metanephrines with seated sampling in our centre.

  2. European Respiratory Society guidelines for the diagnosis of primary ciliary dyskinesia.

    PubMed

    Lucas, Jane S; Barbato, Angelo; Collins, Samuel A; Goutaki, Myrofora; Behan, Laura; Caudri, Daan; Dell, Sharon; Eber, Ernst; Escudier, Estelle; Hirst, Robert A; Hogg, Claire; Jorissen, Mark; Latzin, Philipp; Legendre, Marie; Leigh, Margaret W; Midulla, Fabio; Nielsen, Kim G; Omran, Heymut; Papon, Jean-Francois; Pohunek, Petr; Redfern, Beatrice; Rigau, David; Rindlisbacher, Bernhard; Santamaria, Francesca; Shoemark, Amelia; Snijders, Deborah; Tonia, Thomy; Titieni, Andrea; Walker, Woolf T; Werner, Claudius; Bush, Andrew; Kuehni, Claudia E

    2017-01-01

    The diagnosis of primary ciliary dyskinesia is often confirmed with standard, albeit complex and expensive, tests. In many cases, however, the diagnosis remains difficult despite the array of sophisticated diagnostic tests. There is no "gold standard" reference test. Hence, a Task Force supported by the European Respiratory Society has developed this guideline to provide evidence-based recommendations on diagnostic testing, especially in light of new developments in such tests, and the need for robust diagnoses of patients who might enter randomised controlled trials of treatments. The guideline is based on pre-defined questions relevant for clinical care, a systematic review of the literature, and assessment of the evidence using the GRADE (Grading of Recommendations, Assessment, Development and Evaluation) approach. It focuses on clinical presentation, nasal nitric oxide, analysis of ciliary beat frequency and pattern by high-speed video-microscopy analysis, transmission electron microscopy, genotyping and immunofluorescence. It then used a modified Delphi survey to develop an algorithm for the use of diagnostic tests to definitively confirm and exclude the diagnosis of primary ciliary dyskinesia; and to provide advice when the diagnosis was not conclusive. Finally, this guideline proposes a set of quality criteria for future research on the validity of diagnostic methods for primary ciliary dyskinesia. Copyright ©ERS 2017.

  3. Background review for diagnostic test development for Zika virus infection

    PubMed Central

    Charrel, Rémi N; Leparc-Goffart, Isabelle; Pas, Suzan; de Lamballerie, Xavier; Koopmans, Marion; Reusken, Chantal

    2016-01-01

    Abstract Objective To review the state of knowledge about diagnostic testing for Zika virus infection and identify areas of research needed to address the current gaps in knowledge. Methods We made a non-systematic review of the published literature about Zika virus and supplemented this with information from commercial diagnostic test kits and personal communications with researchers in European preparedness networks. The review covered current knowledge about the geographical spread, pathogen characteristics, life cycle and infection kinetics of the virus. The available molecular and serological tests and biosafety issues are described and discussed in the context of the current outbreak strain. Findings We identified the following areas of research to address current knowledge gaps: (i) an urgent assessment of the laboratory capacity and capability of countries to detect Zika virus; (ii) rapid and extensive field validation of the available molecular and serological tests in areas with and without Zika virus transmission, with a focus on pregnant women; (iii) monitoring the genomic diversity of circulating Zika virus strains; (iv) prospective studies into the virus infection kinetics, focusing on diagnostic sampling (specimen types, combinations and timings); and (v) developing external quality assessments for molecular and serological testing, including differential diagnosis for similar viruses and symptom clusters. The availability of reagents for diagnostic development (virus strains and antigens, quantified viral ribonucleic acid) needs to be facilitated. Conclusion An international laboratory response is needed, including preparation of protocols for prospective studies to address the most pressing information needs. PMID:27516635

  4. A dynamic integrated fault diagnosis method for power transformers.

    PubMed

    Gao, Wensheng; Bai, Cuifen; Liu, Tong

    2015-01-01

    In order to diagnose transformer fault efficiently and accurately, a dynamic integrated fault diagnosis method based on Bayesian network is proposed in this paper. First, an integrated fault diagnosis model is established based on the causal relationship among abnormal working conditions, failure modes, and failure symptoms of transformers, aimed at obtaining the most possible failure mode. And then considering the evidence input into the diagnosis model is gradually acquired and the fault diagnosis process in reality is multistep, a dynamic fault diagnosis mechanism is proposed based on the integrated fault diagnosis model. Different from the existing one-step diagnosis mechanism, it includes a multistep evidence-selection process, which gives the most effective diagnostic test to be performed in next step. Therefore, it can reduce unnecessary diagnostic tests and improve the accuracy and efficiency of diagnosis. Finally, the dynamic integrated fault diagnosis method is applied to actual cases, and the validity of this method is verified.

  5. A Dynamic Integrated Fault Diagnosis Method for Power Transformers

    PubMed Central

    Gao, Wensheng; Liu, Tong

    2015-01-01

    In order to diagnose transformer fault efficiently and accurately, a dynamic integrated fault diagnosis method based on Bayesian network is proposed in this paper. First, an integrated fault diagnosis model is established based on the causal relationship among abnormal working conditions, failure modes, and failure symptoms of transformers, aimed at obtaining the most possible failure mode. And then considering the evidence input into the diagnosis model is gradually acquired and the fault diagnosis process in reality is multistep, a dynamic fault diagnosis mechanism is proposed based on the integrated fault diagnosis model. Different from the existing one-step diagnosis mechanism, it includes a multistep evidence-selection process, which gives the most effective diagnostic test to be performed in next step. Therefore, it can reduce unnecessary diagnostic tests and improve the accuracy and efficiency of diagnosis. Finally, the dynamic integrated fault diagnosis method is applied to actual cases, and the validity of this method is verified. PMID:25685841

  6. Detection of Catheter-Related Bloodstream Infections by the Differential-Time-to-Positivity Method and Gram Stain-Acridine Orange Leukocyte Cytospin Test in Neutropenic Patients after Hematopoietic Stem Cell Transplantation

    PubMed Central

    Krause, R.; Auner, H. W.; Gorkiewicz, G.; Wölfler, A.; Daxboeck, F.; Linkesch, W.; Krejs, G. J.; Wenisch, C.; Reisinger, E. C.

    2004-01-01

    For febrile neutropenic patients who received hematopoietic stem cell transplantation, the Gram stain-acridine orange leukocyte cytospin (AOLC) test and the differential-time-to-positivity method (DTP) were performed. As a diagnostic tool for catheter-related bloodstream infections in these patients, the Gram stain-AOLC test has a lower sensitivity than does the DTP method but acceptable positive and negative predictive values. PMID:15472355

  7. Diagnosis before treatment: Identifying dairy farmers' determinants for the adoption of sustainable practices in gastrointestinal nematode control.

    PubMed

    Vande Velde, F; Claerebout, E; Cauberghe, V; Hudders, L; Van Loo, H; Vercruysse, J; Charlier, J

    2015-09-15

    Anthelmintic resistance is emerging in dairy cattle and this can result in a lack of effective control and production losses. Therefore, sustainable control strategies, such as targeted treatments (TT) and targeted selected treatments (TST), should be adopted by the industry. TT and TST approaches require the use of diagnostic methods to take informed treatment decisions. To understand the factors affecting the farmers' intention to adopt diagnostic methods before implementing anthelmintic drugs ('adoption intention'), a cross-sectional survey was carried out in dairy farms in Belgium (Flanders). A framework was constructed to predict adoption intentions based on two fundamental theories in the field of behavioural psychology and health psychology: the Theory of Planned Behaviour and the Health Belief Model. In the tested model, adoption intentions were predicted based on attitudes towards anthelminthics, attitudes towards diagnostic methods, subjective norms, behavioural control and perceived risk. Structural equation modelling was used for analyses. The model fitted the data well and explained 46% of the variance in adoption intention of diagnostics. The factors 'attitude towards diagnostic methods' and 'subjective norm'; i.e. the influence of significant others, had the strongest, positive influence on adoption intention of diagnostic methods. 'Perceived behavioural control' had a weak, positive effect on intention. Further, 'attitude towards the use of anthelmintic drugs' had a negative effect on adoption intention of the diagnostic methods. This implicates an effect of current behaviour on future adoption, which should be considered in future research. Factors measuring risk perception of anthelmintic resistance; perceived severity and perceived susceptibility, had no effect on the adoption intention of diagnostic methods. The threat of anthelmintic resistance is perceived to be low for dairy herds. The study further did not find any differences in the effects of the predictors for young stock and adult dairy cows. The results of this study can be used to develop communication strategies to advertise sustainable nematode control on dairy farms. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Sensitivity for Diagnosing Group A Streptococcal Pharyngitis from Manufacturers is 10% Higher than Reported in Peer-Reviewed Publications.

    PubMed

    Vachhani, Raj; Patel, Toral; Centor, Robert M; Estrada, Carlos A

    2017-01-01

    Meta-analyses based on peer-reviewed publications report a sensitivity of approximately 85% for rapid antigen streptococcus tests to diagnose group A streptococcal (GAS) pharyngitis. Because these meta-analyses excluded package inserts, we examined the test characteristics of rapid antigen streptococcal tests and molecular methods that manufacturers report in their package inserts. We included tests available in the US market (Food and Drug Administration, period searched 1993-2015) and used package insert data to calculate pooled sensitivity and specificity. To examine quality, we used the Quality Assessment of Diagnostic Accuracy Studies-2. We excluded 26 tests having different trade names but identical methods and data. The study design was prospective in 41.7% (10 of 24). The pooled sensitivity of the most commonly used method, lateral flow/immunochromatographic, was 95% (95% confidence interval [CI] 94-96) and the pooled specificity was 98% (96-98); 7108 patients. The pooled sensitivity of the polymerase chain reaction or molecular methods was 98% (95% CI 96-98) and the pooled specificity was 96% (95% CI 95-97); 5685 patients. Package inserts include sponsored studies that overestimate the sensitivity of rapid tests to diagnose GAS pharyngitis by approximately 10%. Physicians should understand that package inserts overestimate diagnostic test utility; a negative test cannot be used to exclude GAS pharyngitis.

  9. Improved diagnostics of chronic inflammatory prostatitis.

    PubMed

    Kulchavenya, E; Azizoff, A; Brizhatyuk, E; Khomyakov, V; Kholtobin, D; Breusoff, A; Naber, K G

    2012-12-01

    Prostatitis is a prevalent condition that encompasses a large array of clinical symptoms with significant impacts on men's life. The diagnosis and treatment of this disorder presents numerous challenges for urologists, most notably, a lack of specific and effective diagnostic methods. To improve the diagnostics the comparison of classic 4-glass test Meares and Stamey, 2-glass tests and 3-glass test was conducted in 177 men suspicious for chronic prostatitis. Four-glass test is uncomfortable both for patients and doctors, and leads to contamination of urine with prostatic secretion. Two-glass test is insufficiently effective too. Three-glass test (three urine specimens obtained from one continuous micturition stream) gives more adequate results and may be used for screening. Three-glass test as screening test with the option of an additional EPS investigation in those patients the final diagnosis of chronic prostatitis has to be confirmed is more convenient for patients and doctors than the standard M&S 4-glass test and "false-positive" (contaminated with EPS) midstream urine results are avoided thus improving discrimination of urethritis, cystitis and prostatitis. Therefore, we recommend the KE 3-glass test as a new standard for screening patients with signs and symptoms of chronic inflammatory prostatitis.

  10. The diagnostic performance of perfusion MRI for differentiating glioma recurrence from pseudoprogression: A meta-analysis.

    PubMed

    Wan, Bing; Wang, Siqi; Tu, Mengqi; Wu, Bo; Han, Ping; Xu, Haibo

    2017-03-01

    The purpose of this meta-analysis was to evaluate the diagnostic accuracy of perfusion magnetic resonance imaging (MRI) as a method for differentiating glioma recurrence from pseudoprogression. The PubMed, Embase, Cochrane Library, and Chinese Biomedical databases were searched comprehensively for relevant studies up to August 3, 2016 according to specific inclusion and exclusion criteria. The quality of the included studies was assessed according to the quality assessment of diagnostic accuracy studies (QUADAS-2). After performing heterogeneity and threshold effect tests, pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Publication bias was evaluated visually by a funnel plot and quantitatively using Deek funnel plot asymmetry test. The area under the summary receiver operating characteristic curve was calculated to demonstrate the diagnostic performance of perfusion MRI. Eleven studies covering 416 patients and 418 lesions were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 0.88 (95% confidence interval [CI] 0.84-0.92), 0.77 (95% CI 0.69-0.84), 3.93 (95% CI 2.83-5.46), 0.16 (95% CI 0.11-0.22), and 27.17 (95% CI 14.96-49.35), respectively. The area under the summary receiver operating characteristic curve was 0.8899. There was no notable publication bias. Sensitivity analysis showed that the meta-analysis results were stable and credible. While perfusion MRI is not the ideal diagnostic method for differentiating glioma recurrence from pseudoprogression, it could improve diagnostic accuracy. Therefore, further research on combining perfusion MRI with other imaging modalities is warranted.

  11. A systematic review of methods to diagnose oral dryness and salivary gland function

    PubMed Central

    2012-01-01

    Background The most advocated clinical method for diagnosing salivary dysfunction is to quantitate unstimulated and stimulated whole saliva (sialometry). Since there is an expected and wide variation in salivary flow rates among individuals, the assessment of dysfunction can be difficult. The aim of this systematic review is to evaluate the quality of the evidence for the efficacy of diagnostic methods used to identify oral dryness. Methods A literature search, with specific indexing terms and a hand search, was conducted for publications that described a method to diagnose oral dryness. The electronic databases of PubMed, Cochrane Library, and Web of Science were used as data sources. Four reviewers selected publications on the basis of predetermined inclusion and exclusion criteria. Data were extracted from the selected publications using a protocol. Original studies were interpreted with the aid of Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. Results The database searches resulted in 224 titles and abstracts. Of these abstracts, 80 publications were judged to meet the inclusion criteria and read in full. A total of 18 original studies were judged relevant and interpreted for this review. In all studies, the results of the test method were compared to those of a reference method. Based on the interpretation (with the aid of the QUADAS tool) it can be reported that the patient selection criteria were not clearly described and the test or reference methods were not described in sufficient detail for it to be reproduced. None of the included studies reported information on uninterpretable/intermediate results nor data on observer or instrument variation. Seven of the studies presented their results as a percentage of correct diagnoses. Conclusions The evidence for the efficacy of clinical methods to assess oral dryness is sparse and it can be stated that improved standards for the reporting of diagnostic accuracy are needed in order to assure the methodological quality of studies. There is need for effective diagnostic criteria and functional tests in order to detect those individuals with oral dryness who may require oral treatment, such as alleviation of discomfort and/or prevention of diseases. PMID:22870895

  12. Receiver operating characteristic analysis of eyewitness memory: comparing the diagnostic accuracy of simultaneous versus sequential lineups.

    PubMed

    Mickes, Laura; Flowe, Heather D; Wixted, John T

    2012-12-01

    A police lineup presents a real-world signal-detection problem because there are two possible states of the world (the suspect is either innocent or guilty), some degree of information about the true state of the world is available (the eyewitness has some degree of memory for the perpetrator), and a decision is made (identifying the suspect or not). A similar state of affairs applies to diagnostic tests in medicine because, in a patient, the disease is either present or absent, a diagnostic test yields some degree of information about the true state of affairs, and a decision is made about the presence or absence of the disease. In medicine, receiver operating characteristic (ROC) analysis is the standard method for assessing diagnostic accuracy. By contrast, in the eyewitness memory literature, this powerful technique has never been used. Instead, researchers have attempted to assess the diagnostic performance of different lineup procedures using methods that cannot identify the better procedure (e.g., by computing a diagnosticity ratio). Here, we describe the basics of ROC analysis, explaining why it is needed and showing how to use it to measure the performance of different lineup procedures. To illustrate the unique advantages of this technique, we also report 3 ROC experiments that were designed to investigate the diagnostic accuracy of simultaneous versus sequential lineups. According to our findings, the sequential procedure appears to be inferior to the simultaneous procedure in discriminating between the presence versus absence of a guilty suspect in a lineup.

  13. Detecting Renibacterium salmoninarum in wild brown trout by use of multiple organ samples and diagnostic methods

    USGS Publications Warehouse

    Guomundsdottir, S.; Applegate, Lynn M.; Arnason, I.O.; Kristmundsson, A.; Purcell, Maureen K.; Elliott, Diane G.

    2017-01-01

    Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease (BKD), is endemic in many wild trout species in northerly regions. The aim of the present study was to determine the optimal R. salmoninarum sampling/testing strategy for wild brown trout (Salmo trutta L.) populations in Iceland. Fish were netted in a lake and multiple organs—kidney, spleen, gills, oesophagus and mid-gut—were sampled and subjected to five detection tests i.e. culture, polyclonal enzyme-linked immunosorbent assay (pELISA) and three different PCR tests. The results showed that each fish had encountered R. salmoninarum but there were marked differences between results obtained depending on organ and test. The bacterium was not cultured from any kidney sample while all kidney samples were positive by pELISA. At least one organ from 92.9% of the fish tested positive by PCR. The results demonstrated that the choice of tissue and diagnostic method can dramatically influence the outcome of R. salmoninarum surveys.

  14. Testing Measurement Invariance across Groups of Children with and without Attention-Deficit/ Hyperactivity Disorder: Applications for Word Recognition and Spelling Tasks

    PubMed Central

    Lúcio, Patrícia S.; Salum, Giovanni; Swardfager, Walter; Mari, Jair de Jesus; Pan, Pedro M.; Bressan, Rodrigo A.; Gadelha, Ary; Rohde, Luis A.; Cogo-Moreira, Hugo

    2017-01-01

    Although studies have consistently demonstrated that children with attention-deficit/hyperactivity disorder (ADHD) perform significantly lower than controls on word recognition and spelling tests, such studies rely on the assumption that those groups are comparable in these measures. This study investigates comparability of word recognition and spelling tests based on diagnostic status for ADHD through measurement invariance methods. The participants (n = 1,935; 47% female; 11% ADHD) were children aged 6–15 with normal IQ (≥70). Measurement invariance was investigated through Confirmatory Factor Analysis and Multiple Indicators Multiple Causes models. Measurement invariance was attested in both methods, demonstrating the direct comparability of the groups. Children with ADHD were 0.51 SD lower in word recognition and 0.33 SD lower in spelling tests than controls. Results suggest that differences in performance on word recognition and spelling tests are related to true mean differences based on ADHD diagnostic status. Implications for clinical practice and research are discussed. PMID:29118733

  15. Testing Measurement Invariance across Groups of Children with and without Attention-Deficit/ Hyperactivity Disorder: Applications for Word Recognition and Spelling Tasks.

    PubMed

    Lúcio, Patrícia S; Salum, Giovanni; Swardfager, Walter; Mari, Jair de Jesus; Pan, Pedro M; Bressan, Rodrigo A; Gadelha, Ary; Rohde, Luis A; Cogo-Moreira, Hugo

    2017-01-01

    Although studies have consistently demonstrated that children with attention-deficit/hyperactivity disorder (ADHD) perform significantly lower than controls on word recognition and spelling tests, such studies rely on the assumption that those groups are comparable in these measures. This study investigates comparability of word recognition and spelling tests based on diagnostic status for ADHD through measurement invariance methods. The participants ( n = 1,935; 47% female; 11% ADHD) were children aged 6-15 with normal IQ (≥70). Measurement invariance was investigated through Confirmatory Factor Analysis and Multiple Indicators Multiple Causes models. Measurement invariance was attested in both methods, demonstrating the direct comparability of the groups. Children with ADHD were 0.51 SD lower in word recognition and 0.33 SD lower in spelling tests than controls. Results suggest that differences in performance on word recognition and spelling tests are related to true mean differences based on ADHD diagnostic status. Implications for clinical practice and research are discussed.

  16. Culture-independent diagnostics for health security

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doggett, Norman A.; Mukundan, Harshini; Lefkowitz, Elliot J.

    The past decade has seen considerable development in the diagnostic application of nonculture methods, including nucleic acid amplification-based methods and mass spectrometry, for the diagnosis of infectious diseases. The implications of these new culture-independent diagnostic tests (CIDTs) include bypassing the need to culture organisms, thus potentially affecting public health surveillance systems, which continue to use isolates as the basis of their surveillance programs and to assess phenotypic resistance to antimicrobial agents. CIDTs may also affect the way public health practitioners detect and respond to a bioterrorism event. In response to a request from the Department of Homeland Security, Los Alamosmore » National Laboratory and the Centers for Disease Control and Prevention cosponsored a workshop to review the impact of CIDTs on the rapid detection and identification of biothreat agents. Four panel discussions were held that covered nucleic acid amplification–based diagnostics, mass spectrometry, antibody-based diagnostics, and next-generation sequencing. Exploiting the extensive expertise available at this workshop, we identified the key features, benefits, and limitations of the various CIDT methods for providing rapid pathogen identification that are critical to the response and mitigation of a bioterrorism event. After the workshop we conducted a thorough review of the literature, investigating the current state of these 4 culture-independent diagnostic methods. Furthermore, this article combines information from the literature review and the insights obtained at the workshop.« less

  17. Culture-independent diagnostics for health security

    DOE PAGES

    Doggett, Norman A.; Mukundan, Harshini; Lefkowitz, Elliot J.; ...

    2016-06-17

    The past decade has seen considerable development in the diagnostic application of nonculture methods, including nucleic acid amplification-based methods and mass spectrometry, for the diagnosis of infectious diseases. The implications of these new culture-independent diagnostic tests (CIDTs) include bypassing the need to culture organisms, thus potentially affecting public health surveillance systems, which continue to use isolates as the basis of their surveillance programs and to assess phenotypic resistance to antimicrobial agents. CIDTs may also affect the way public health practitioners detect and respond to a bioterrorism event. In response to a request from the Department of Homeland Security, Los Alamosmore » National Laboratory and the Centers for Disease Control and Prevention cosponsored a workshop to review the impact of CIDTs on the rapid detection and identification of biothreat agents. Four panel discussions were held that covered nucleic acid amplification–based diagnostics, mass spectrometry, antibody-based diagnostics, and next-generation sequencing. Exploiting the extensive expertise available at this workshop, we identified the key features, benefits, and limitations of the various CIDT methods for providing rapid pathogen identification that are critical to the response and mitigation of a bioterrorism event. After the workshop we conducted a thorough review of the literature, investigating the current state of these 4 culture-independent diagnostic methods. Furthermore, this article combines information from the literature review and the insights obtained at the workshop.« less

  18. Culture-Independent Diagnostics for Health Security.

    PubMed

    Doggett, Norman A; Mukundan, Harshini; Lefkowitz, Elliot J; Slezak, Tom R; Chain, Patrick S; Morse, Stephen; Anderson, Kevin; Hodge, David R; Pillai, Segaran

    2016-01-01

    The past decade has seen considerable development in the diagnostic application of nonculture methods, including nucleic acid amplification-based methods and mass spectrometry, for the diagnosis of infectious diseases. The implications of these new culture-independent diagnostic tests (CIDTs) include bypassing the need to culture organisms, thus potentially affecting public health surveillance systems, which continue to use isolates as the basis of their surveillance programs and to assess phenotypic resistance to antimicrobial agents. CIDTs may also affect the way public health practitioners detect and respond to a bioterrorism event. In response to a request from the Department of Homeland Security, Los Alamos National Laboratory and the Centers for Disease Control and Prevention cosponsored a workshop to review the impact of CIDTs on the rapid detection and identification of biothreat agents. Four panel discussions were held that covered nucleic acid amplification-based diagnostics, mass spectrometry, antibody-based diagnostics, and next-generation sequencing. Exploiting the extensive expertise available at this workshop, we identified the key features, benefits, and limitations of the various CIDT methods for providing rapid pathogen identification that are critical to the response and mitigation of a bioterrorism event. After the workshop we conducted a thorough review of the literature, investigating the current state of these 4 culture-independent diagnostic methods. This article combines information from the literature review and the insights obtained at the workshop.

  19. Journal: Efficient Hydrologic Tracer-Test Design for Tracer-Mass Estimation and Sample Collection Frequency, 1 Method Development

    EPA Science Inventory

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...

  20. New Testing Methods to Assess Technical Problem-Solving Ability.

    ERIC Educational Resources Information Center

    Hambleton, Ronald K.; And Others

    Tests to assess problem-solving ability being provided for the Air Force are described, and some details on the development and validation of these computer-administered diagnostic achievement tests are discussed. Three measurement approaches were employed: (1) sequential problem solving; (2) context-free assessment of fundamental skills and…

  1. Comparison of diagnostic methods in the evaluation of onychomycosis.

    PubMed

    Haghani, Iman; Shokohi, Tahereh; Hajheidari, Zohreh; Khalilian, Alireza; Aghili, Seyed Reza

    2013-04-01

    Onychomycosis is a common nail problem, accounting for up to half of all nail diseases. Several nail disorders may mimic the onychomycosis clinically. Therefore, a sensitive, quick, and inexpensive test is essential for screening nail specimens for the administration of the proper drug. The aim of this study was to compare 4 different diagnostic methods in the evaluation of onychomycosis and to determine their sensitivity, specificity, positive predictive value, and negative predictive value. In a cross-sectional study, nail specimens were collected from 101 patients suspected to have onychomycosis during a 14-month period. The nail specimens were examined using potassium hydroxide (KOH) 20 %, KOH-treated nail clipping stained with periodic acid-Schiff (KONCPA), and calcofluor white (CFW) stain, and grew a fungal culture. The culture was chosen as the gold standard for statistical analysis using the McNemar and chi-square tests. Out of 101 patients, 100 (99 %) patients had at least 1 of the 4 diagnostic methods positive for the presence of organisms. The positive rates for the fungal culture, KOH preparation, CFW, and KONCPA were 74.2, 85.1, 91.09, and 99.01 %, respectively. The sensitivity and negative predictive value of KONCPA was 100 %. KONCPA was the most sensitive among the tests and was also superior to other methods in its negative predictive value. KONCPA was easy to perform, rapid, and gave significantly higher rates of detection of onychomycosis compared to the standard methods of KOH preparation and fungal culture. Therefore, KONCPA should be the single method of choice for the evaluation of onychomycosis.

  2. A lab-on-chip for malaria diagnosis and surveillance

    PubMed Central

    2014-01-01

    Background Access to timely and accurate diagnostic tests has a significant impact in the management of diseases of global concern such as malaria. While molecular diagnostics satisfy this need effectively in developed countries, barriers in technology, reagent storage, cost and expertise have hampered the introduction of these methods in developing countries. In this study a simple, lab-on-chip PCR diagnostic was created for malaria that overcomes these challenges. Methods The platform consists of a disposable plastic chip and a low-cost, portable, real-time PCR machine. The chip contains a desiccated hydrogel with reagents needed for Plasmodium specific PCR. Chips can be stored at room temperature and used on demand by rehydrating the gel with unprocessed blood, avoiding the need for sample preparation. These chips were run on a custom-built instrument containing a Peltier element for thermal cycling and a laser/camera setup for amplicon detection. Results This diagnostic was capable of detecting all Plasmodium species with a limit of detection for Plasmodium falciparum of 2 parasites/μL of blood. This exceeds the sensitivity of microscopy, the current standard for diagnosis in the field, by ten to fifty-fold. In a blind panel of 188 patient samples from a hyper-endemic region of malaria transmission in Uganda, the diagnostic had high sensitivity (97.4%) and specificity (93.8%) versus conventional real-time PCR. The test also distinguished the two most prevalent malaria species in mixed infections, P. falciparum and Plasmodium vivax. A second blind panel of 38 patient samples was tested on a streamlined instrument with LED-based excitation, achieving a sensitivity of 96.7% and a specificity of 100%. Conclusions These results describe the development of a lab-on-chip PCR diagnostic from initial concept to ready-for-manufacture design. This platform will be useful in front-line malaria diagnosis, elimination programmes, and clinical trials. Furthermore, test chips can be adapted to detect other pathogens for a differential diagnosis in the field. The flexibility, reliability, and robustness of this technology hold much promise for its use as a novel molecular diagnostic platform in developing countries. PMID:24885206

  3. Diagnostic value of two commercial chromatographic "patient-side" tests in the diagnosis of acute canine leptospirosis.

    PubMed

    Gloor, C I; Schweighauser, A; Francey, T; Rodriguez-Campos, S; Vidondo, B; Bigler, B; Schuller, S

    2017-03-01

    To determine the diagnostic performance of two patient-side tests (RDT-1: Test-it™ and RDT-2 Witness®Lepto) in the early diagnosis of canine leptospirosis. Retrospective study of 108 dogs with leptospirosis and 53 controls. Leptospirosis was diagnosed based on compatible clinical and clinicopathologic signs and either a single microscopic agglutination test titre_ >800 (n=49), seroconversion (n=53), positive urine real time PCR (RT-PCR) (n=1), evidence of spirochaetes in silver-stained tissues (n=1) or a combination of these (n=4). Leptospirosis was excluded in dogs with a convincing alternative diagnosis and single microscopic agglutination testing titres _<200 (n=46) or lack of seroconversion (n=7). Indices of diagnostic accuracy of the rapid diagnostic tests were calculated by comparing admission rapid diagnostic test results to the final disease status. Rapid diagnostic test-1 was performed in 118 dogs, rapid diagnostic test-2 in 69 dogs and both tests in 26 dogs. Weak positive results occurred frequently representing 22·6% (rapid diagnostic test-1) and 32·3% (rapid diagnostic test-2) of all positive tests in dogs with leptospirosis. If weak positive rapid diagnostic tests were considered positive, rapid diagnostic test-1 and rapid diagnostic test-2 had sensitivities of 82 and 76%, specificities of 91 and 100%, positive predictive values of 94% and 100% and negative predictive values of 73% and 74%, respectively. There were some technical problems with rapid diagnostic test-1. The diagnostic performance of the rapid diagnostic tests is similar to that reported for the microscopic agglutination test. Both can support a diagnosis of leptospirosis with high specificity but leptospirosis cannot be excluded based on a negative admission test result. Both RDTs are useful in conjunction with other confirmatory tests. © 2017 British Small Animal Veterinary Association.

  4. Assessment of colon polyp morphology: Is education effective?

    PubMed Central

    Kim, Jae Hyun; Nam, Kyoung Sik; Kwon, Hye Jung; Choi, Youn Jung; Jung, Kyoungwon; Kim, Sung Eun; Moon, Won; Park, Moo In; Park, Seun Ja

    2017-01-01

    AIM To determine the inter-observer variability for colon polyp morphology and to identify whether education can improve agreement among observers. METHODS For purposes of the tests, we recorded colonoscopy video clips that included scenes visualizing the polyps. A total of 15 endoscopists and 15 nurses participated in the study. Participants watched 60 video clips of the polyp morphology scenes and then estimated polyp morphology (pre-test). After education for 20 min, participants performed a second test in which the order of 60 video clips was changed (post-test). To determine if the effectiveness of education was sustained, four months later, a third, follow-up test was performed with the same participants. RESULTS The overall Fleiss’ kappa value of the inter-observer agreement was 0.510 in the pre-test, 0.618 in the post-test, and 0.580 in the follow-up test. The overall diagnostic accuracy of the estimation for polyp morphology in the pre-, post-, and follow-up tests was 0.662, 0.797, and 0.761, respectively. After education, the inter-observer agreement and diagnostic accuracy of all participants improved. However, after four months, the inter-observer agreement and diagnostic accuracy of expert groups were markedly decreased, and those of beginner and nurse groups remained similar to pre-test levels. CONCLUSION The education program used in this study can improve inter-observer agreement and diagnostic accuracy in assessing the morphology of colon polyps; it is especially effective when first learning endoscopy. PMID:28974894

  5. Detection of clinically relevant copy-number variants by exome sequencing in a large cohort of genetic disorders

    PubMed Central

    Pfundt, Rolph; del Rosario, Marisol; Vissers, Lisenka E.L.M.; Kwint, Michael P.; Janssen, Irene M.; de Leeuw, Nicole; Yntema, Helger G.; Nelen, Marcel R.; Lugtenberg, Dorien; Kamsteeg, Erik-Jan; Wieskamp, Nienke; Stegmann, Alexander P.A.; Stevens, Servi J.C.; Rodenburg, Richard J.T.; Simons, Annet; Mensenkamp, Arjen R.; Rinne, Tuula; Gilissen, Christian; Scheffer, Hans; Veltman, Joris A.; Hehir-Kwa, Jayne Y.

    2017-01-01

    Purpose: Copy-number variation is a common source of genomic variation and an important genetic cause of disease. Microarray-based analysis of copy-number variants (CNVs) has become a first-tier diagnostic test for patients with neurodevelopmental disorders, with a diagnostic yield of 10–20%. However, for most other genetic disorders, the role of CNVs is less clear and most diagnostic genetic studies are generally limited to the study of single-nucleotide variants (SNVs) and other small variants. With the introduction of exome and genome sequencing, it is now possible to detect both SNVs and CNVs using an exome- or genome-wide approach with a single test. Methods: We performed exome-based read-depth CNV screening on data from 2,603 patients affected by a range of genetic disorders for which exome sequencing was performed in a diagnostic setting. Results: In total, 123 clinically relevant CNVs ranging in size from 727 bp to 15.3 Mb were detected, which resulted in 51 conclusive diagnoses and an overall increase in diagnostic yield of ~2% (ranging from 0 to –5.8% per disorder). Conclusions: This study shows that CNVs play an important role in a broad range of genetic disorders and that detection via exome-based CNV profiling results in an increase in the diagnostic yield without additional testing, bringing us closer to single-test genomics. Genet Med advance online publication 27 October 2016 PMID:28574513

  6. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    PubMed Central

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  7. MDR-TB screening in a setting with molecular diagnostic techniques: who got tested, who didn't and why?

    PubMed Central

    Govindarajan, S.; Sharath, B. N.; Tripathy, J. P.; Chinnakali, P.; Kumar, A. M. V.; Muthaiah, M.; Vivekananda, K.; Paulraj, A. K.; Roy, G.

    2015-01-01

    Setting: The Revised National Tuberculosis Control Programme, Puducherry, India, which has facilities for molecular diagnostic technique. Objective: To determine pre-diagnostic and pre-treatment attrition among presumptive multidrug-resistant tuberculosis (MDR-TB) patients and reasons for attrition. Methods: In this mixed-methods study, the quantitative component consisted of retrospective cohort analysis through record review of all presumptive MDR-TB patients recorded between October 2012 and September 2013. The qualitative component included in-depth interviews with key informants involved in programmatic management of drug-resistant tuberculosis services. Results: Of 341 eligible presumptive MDR-TB patients, pre-diagnostic and pre-treatment attrition was respectively 45.5% (155/341) and 29% (2/7). Patients with extra-pulmonary TB (RR = 2.3), those with human immuno-deficiency and TB co-infection (RR = 1.7), those registered during October–December 2012 (RR = 1.3) and those identified from primary/secondary health centres (RR = 1.8) were less likely to be tested. Themes that emerged during the analysis of the qualitative data were ‘lack of a systematic mechanism to track referrals for culture and drug susceptibility testing’, ‘absence of courier service to transport sputum’, ‘lack of knowledge and ownership among staff of general health system’, ‘shortage of diagnostic kits’ and ‘patient non-adherence’. Conclusion: Despite the introduction of molecular diagnostic techniques, operational issues in MDR-TB screening remain a concern and require urgent attention. PMID:26400385

  8. It's Time for a Conceptual Change.

    ERIC Educational Resources Information Center

    Hausfather, Samuel J.

    1992-01-01

    Conceptual change teaching is an instructional method that helps students modify, extend, or exchange their alternative conceptions for the appropriate scientific conceptions. Provides activities and a diagnostic test to apply the method to the concepts of heat and temperature. (MDH)

  9. Evaluation of Targeted Next-Generation Sequencing for Detection of Bovine Pathogens in Clinical Samples.

    PubMed

    Anis, Eman; Hawkins, Ian K; Ilha, Marcia R S; Woldemeskel, Moges W; Saliki, Jeremiah T; Wilkes, Rebecca P

    2018-07-01

    The laboratory diagnosis of infectious diseases, especially those caused by mixed infections, is challenging. Routinely, it requires submission of multiple samples to separate laboratories. Advances in next-generation sequencing (NGS) have provided the opportunity for development of a comprehensive method to identify infectious agents. This study describes the use of target-specific primers for PCR-mediated amplification with the NGS technology in which pathogen genomic regions of interest are enriched and selectively sequenced from clinical samples. In the study, 198 primers were designed to target 43 common bovine and small-ruminant bacterial, fungal, viral, and parasitic pathogens, and a bioinformatics tool was specifically constructed for the detection of targeted pathogens. The primers were confirmed to detect the intended pathogens by testing reference strains and isolates. The method was then validated using 60 clinical samples (including tissues, feces, and milk) that were also tested with other routine diagnostic techniques. The detection limits of the targeted NGS method were evaluated using 10 representative pathogens that were also tested by quantitative PCR (qPCR), and the NGS method was able to detect the organisms from samples with qPCR threshold cycle ( C T ) values in the 30s. The method was successful for the detection of multiple pathogens in the clinical samples, including some additional pathogens missed by the routine techniques because the specific tests needed for the particular organisms were not performed. The results demonstrate the feasibility of the approach and indicate that it is possible to incorporate NGS as a diagnostic tool in a cost-effective manner into a veterinary diagnostic laboratory. Copyright © 2018 Anis et al.

  10. Cosmological model-independent test of ΛCDM with two-point diagnostic by the observational Hubble parameter data

    NASA Astrophysics Data System (ADS)

    Cao, Shu-Lei; Duan, Xiao-Wei; Meng, Xiao-Lei; Zhang, Tong-Jie

    2018-04-01

    Aiming at exploring the nature of dark energy (DE), we use forty-three observational Hubble parameter data (OHD) in the redshift range 0 < z ≤slant 2.36 to make a cosmological model-independent test of the ΛCDM model with two-point Omh^2(z2;z1) diagnostic. In ΛCDM model, with equation of state (EoS) w=-1, two-point diagnostic relation Omh^2 ≡ Ωmh^2 is tenable, where Ωm is the present matter density parameter, and h is the Hubble parameter divided by 100 {km s^{-1 Mpc^{-1}}}. We utilize two methods: the weighted mean and median statistics to bin the OHD to increase the signal-to-noise ratio of the measurements. The binning methods turn out to be promising and considered to be robust. By applying the two-point diagnostic to the binned data, we find that although the best-fit values of Omh^2 fluctuate as the continuous redshift intervals change, on average, they are continuous with being constant within 1 σ confidence interval. Therefore, we conclude that the ΛCDM model cannot be ruled out.

  11. Supervisory control and diagnostics system for the mirror fusion test facility: overview and status 1980

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McGoldrick, P.R.

    1981-01-01

    The Mirror Fusion Test Facility (MFTF) is a complex facility requiring a highly-computerized Supervisory Control and Diagnostics System (SCDS) to monitor and provide control over ten subsystems; three of which require true process control. SCDS will provide physicists with a method of studying machine and plasma behavior by acquiring and processing up to four megabytes of plasma diagnostic information every five minutes. A high degree of availability and throughput is provided by a distributed computer system (nine 32-bit minicomputers on shared memory). Data, distributed across SCDS, is managed by a high-bandwidth Distributed Database Management System. The MFTF operators' control roommore » consoles use color television monitors with touch sensitive screens; this is a totally new approach. The method of handling deviations to normal machine operation and how the operator should be notified and assisted in the resolution of problems has been studied and a system designed.« less

  12. Comparison of rapid diagnostic tests for the detection of Plasmodium vivax malaria in South Korea.

    PubMed

    Kim, Jung-Yeon; Ji, So-Young; Goo, Youn-Kyoung; Na, Byoung-Kuk; Pyo, Hyo-Joo; Lee, Han-Na; Lee, Juyoung; Kim, Nam Hee; von Seidlein, Lorenz; Cheng, Qin; Cho, Shin-Hyung; Lee, Won-Ja

    2013-01-01

    South Korea is one of many countries with endemic Plasmodium vivax malaria. Here we report the evaluation of four rapid diagnostic tests (RDTs) for diagnosis of this disease. A total of 253 subjects were enrolled in the study. The sensitivities, specificities and agreement frequencies were estimated by comparing the four RDTs against the standard of nested-PCR and microscopic examination. The CareStart(TM) and SD Bioline had higher test sensitivities (99.4 and 98.8%, respectively) compared with the NanoSign and Asan Easy tests (93.0 and 94.7%, respectively). The CareStart(TM) and SD Bioline tests could detect P. vivax in samples with parasite densities <150/μl, which was a slightly better performance than the other two RDTs. The quantitative accuracy of the four RDTs was also estimated by comparing results with P. vivax counts from blood samples. Lower test price would result in increased use of these RDTs in the field. The results of this study contribute valuable information that will aid in the selection of a diagnostic method for the detection of malaria.

  13. Comparison of Rapid Diagnostic Tests for the Detection of Plasmodium vivax Malaria in South Korea

    PubMed Central

    Goo, Youn-Kyoung; Na, Byoung-Kuk; Pyo, Hyo-Joo; Lee, Han-Na; Lee, Juyoung; Kim, Nam Hee; von Seidlein, Lorenz; Cheng, Qin; Cho, Shin-Hyung; Lee, Won-Ja

    2013-01-01

    South Korea is one of many countries with endemic Plasmodium vivax malaria. Here we report the evaluation of four rapid diagnostic tests (RDTs) for diagnosis of this disease. A total of 253 subjects were enrolled in the study. The sensitivities, specificities and agreement frequencies were estimated by comparing the four RDTs against the standard of nested-PCR and microscopic examination. The CareStartTM and SD Bioline had higher test sensitivities (99.4 and 98.8%, respectively) compared with the NanoSign and Asan Easy tests (93.0 and 94.7%, respectively). The CareStartTM and SD Bioline tests could detect P. vivax in samples with parasite densities <150/μl, which was a slightly better performance than the other two RDTs. The quantitative accuracy of the four RDTs was also estimated by comparing results with P. vivax counts from blood samples. Lower test price would result in increased use of these RDTs in the field. The results of this study contribute valuable information that will aid in the selection of a diagnostic method for the detection of malaria. PMID:23667710

  14. Photoacoustic sensor for medical diagnostics

    NASA Astrophysics Data System (ADS)

    Wolff, Marcus; Groninga, Hinrich G.; Harde, Hermann

    2004-03-01

    The development of new optical sensor technologies has a major impact on the progress of diagnostic methods. Of the permanently increasing number of non-invasive breath tests, the 13C-Urea Breath Test (UBT) for the detection of Helicobacter pylori is the most prominent. However, many recent developments, like the detection of cancer by breath test, go beyond gastroenterological applications. We present a new detection scheme for breath analysis that employs an especially compact and simple set-up. Photoacoustic Spectroscopy (PAS) represents an offset-free technique that allows for short absorption paths and small sample cells. Using a single-frequency diode laser and taking advantage of acoustical resonances of the sample cell, we performed extremely sensitive and selective measurements. The smart data processing method contributes to the extraordinary sensitivity and selectivity as well. Also, the reasonable acquisition cost and low operational cost make this detection scheme attractive for many biomedical applications. The experimental set-up and data processing method, together with exemplary isotope-selective measurements on carbon dioxide, are presented.

  15. Can a Smartphone Diagnose Parkinson Disease? A Deep Neural Network Method and Telediagnosis System Implementation.

    PubMed

    Zhang, Y N

    2017-01-01

    Parkinson's disease (PD) is primarily diagnosed by clinical examinations, such as walking test, handwriting test, and MRI diagnostic. In this paper, we propose a machine learning based PD telediagnosis method for smartphone. Classification of PD using speech records is a challenging task owing to the fact that the classification accuracy is still lower than doctor-level. Here we demonstrate automatic classification of PD using time frequency features, stacked autoencoders (SAE), and K nearest neighbor (KNN) classifier. KNN classifier can produce promising classification results from useful representations which were learned by SAE. Empirical results show that the proposed method achieves better performance with all tested cases across classification tasks, demonstrating machine learning capable of classifying PD with a level of competence comparable to doctor. It concludes that a smartphone can therefore potentially provide low-cost PD diagnostic care. This paper also gives an implementation on browser/server system and reports the running time cost. Both advantages and disadvantages of the proposed telediagnosis system are discussed.

  16. Can a Smartphone Diagnose Parkinson Disease? A Deep Neural Network Method and Telediagnosis System Implementation

    PubMed Central

    2017-01-01

    Parkinson's disease (PD) is primarily diagnosed by clinical examinations, such as walking test, handwriting test, and MRI diagnostic. In this paper, we propose a machine learning based PD telediagnosis method for smartphone. Classification of PD using speech records is a challenging task owing to the fact that the classification accuracy is still lower than doctor-level. Here we demonstrate automatic classification of PD using time frequency features, stacked autoencoders (SAE), and K nearest neighbor (KNN) classifier. KNN classifier can produce promising classification results from useful representations which were learned by SAE. Empirical results show that the proposed method achieves better performance with all tested cases across classification tasks, demonstrating machine learning capable of classifying PD with a level of competence comparable to doctor. It concludes that a smartphone can therefore potentially provide low-cost PD diagnostic care. This paper also gives an implementation on browser/server system and reports the running time cost. Both advantages and disadvantages of the proposed telediagnosis system are discussed. PMID:29075547

  17. 40 CFR 85.2223 - On-board diagnostic test report.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false On-board diagnostic test report. 85... Tests § 85.2223 On-board diagnostic test report. (a) Motorists whose vehicles fail the on-board diagnostic test described in § 85.2222 shall be provided with the on-board diagnostic test results, including...

  18. 40 CFR 85.2223 - On-board diagnostic test report.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false On-board diagnostic test report. 85... Tests § 85.2223 On-board diagnostic test report. (a) Motorists whose vehicles fail the on-board diagnostic test described in § 85.2222 shall be provided with the on-board diagnostic test results, including...

  19. Diagnostic methods to assess inspiratory and expiratory muscle strength*

    PubMed Central

    Caruso, Pedro; de Albuquerque, André Luis Pereira; Santana, Pauliane Vieira; Cardenas, Leticia Zumpano; Ferreira, Jeferson George; Prina, Elena; Trevizan, Patrícia Fernandes; Pereira, Mayra Caleffi; Iamonti, Vinicius; Pletsch, Renata; Macchione, Marcelo Ceneviva; Carvalho, Carlos Roberto Ribeiro

    2015-01-01

    Impairment of (inspiratory and expiratory) respiratory muscles is a common clinical finding, not only in patients with neuromuscular disease but also in patients with primary disease of the lung parenchyma or airways. Although such impairment is common, its recognition is usually delayed because its signs and symptoms are nonspecific and late. This delayed recognition, or even the lack thereof, occurs because the diagnostic tests used in the assessment of respiratory muscle strength are not widely known and available. There are various methods of assessing respiratory muscle strength during the inspiratory and expiratory phases. These methods are divided into two categories: volitional tests (which require patient understanding and cooperation); and non-volitional tests. Volitional tests, such as those that measure maximal inspiratory and expiratory pressures, are the most commonly used because they are readily available. Non-volitional tests depend on magnetic stimulation of the phrenic nerve accompanied by the measurement of inspiratory mouth pressure, inspiratory esophageal pressure, or inspiratory transdiaphragmatic pressure. Another method that has come to be widely used is ultrasound imaging of the diaphragm. We believe that pulmonologists involved in the care of patients with respiratory diseases should be familiar with the tests used in order to assess respiratory muscle function.Therefore, the aim of the present article is to describe the advantages, disadvantages, procedures, and clinical applicability of the main tests used in the assessment of respiratory muscle strength. PMID:25972965

  20. Health Technology Assessment for Molecular Diagnostics: Practices, Challenges, and Recommendations from the Medical Devices and Diagnostics Special Interest Group.

    PubMed

    Garfield, Susan; Polisena, Julie; S Spinner, Daryl; Postulka, Anne; Y Lu, Christine; Tiwana, Simrandeep K; Faulkner, Eric; Poulios, Nick; Zah, Vladimir; Longacre, Michael

    2016-01-01

    Health technology assessments (HTAs) are increasingly used to inform coverage, access, and utilization of medical technologies including molecular diagnostics (MDx). Although MDx are used to screen patients and inform disease management and treatment decisions, there is no uniform approach to their evaluation by HTA organizations. The International Society for Pharmacoeconomics and Outcomes Research Devices and Diagnostics Special Interest Group reviewed diagnostic-specific HTA programs and identified elements representing common and best practices. MDx-specific HTA programs in Europe, Australia, and North America were characterized by methodology, evaluation framework, and impact. Published MDx HTAs were reviewed, and five representative case studies of test evaluations were developed: United Kingdom (National Institute for Health and Care Excellence's Diagnostics Assessment Programme, epidermal growth factor receptor tyrosine kinase mutation), United States (Palmetto's Molecular Diagnostic Services Program, OncotypeDx prostate cancer test), Germany (Institute for Quality and Efficiency in Healthcare, human papillomavirus testing), Australia (Medical Services Advisory Committee, anaplastic lymphoma kinase testing for non-small cell lung cancer), and Canada (Canadian Agency for Drugs and Technologies in Health, Rapid Response: Non-invasive Prenatal Testing). Overall, the few HTA programs that have MDx-specific methods do not provide clear parameters of acceptability related to clinical and analytic performance, clinical utility, and economic impact. The case studies highlight similarities and differences in evaluation approaches across HTAs in the performance metrics used (analytic and clinical validity, clinical utility), evidence requirements, and how value is measured. Not all HTAs are directly linked to reimbursement outcomes. To improve MDx HTAs, organizations should provide greater transparency, better communication and collaboration between industry and HTA stakeholders, clearer links between HTA and funding decisions, explicit recognition of and rationale for differential approaches to laboratory-developed versus regulatory-approved test, and clear evidence requirements. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  1. Adoption of Rapid Diagnostic Tests for the Diagnosis of Malaria, a Preliminary Analysis of the Global Fund Program Data, 2005 to 2010

    PubMed Central

    Zhao, Jinkou; Lama, Marcel; Korenromp, Eline; Aylward, Patrick; Shargie, Estifanos; Filler, Scott; Komatsu, Ryuichi; Atun, Rifat

    2012-01-01

    Introduction The World Health Organization Guidelines for the Treatment of Malaria, in 2006 and 2010, recommend parasitological confirmation of malaria before commencing treatment. Although microscopy has been the mainstay of malaria diagnostics, the magnitude of diagnostic scale up required to follow the Guidelines suggests that rapid diagnostic tests (RDTs) will be a large component. This study analyzes the adoption of rapid diagnostic testing in malaria programs supported by the Global Fund to fight AIDS, Tuberculosis and Malaria (Global Fund), the leading international funder of malaria control globally. Methods and Findings We analyzed, for the period 2005 to 2010, Global Fund programmatic data for 81 countries on the quantity of RDTs planned; actual quantities of RDTs and artemisinin-based combination treatments (ACTs) procured in 2009 and 2010; RDT-related activities including RDTs distributed, RDTs used, total diagnostic tests including RDTs and microscopy performed, health facilities equipped with RDTs; personnel trained to perform rapid diagnostic malaria test; and grant budgets allocated to malaria diagnosis. In 2010, diagnosis accounted for 5.2% of malaria grant budget. From 2005 to 2010, the procurement plans include148 million RDTs through 96 malaria grants in 81 countries. Around 115 million parasitological tests, including RDTs, had reportedly been performed from 2005 to 2010. Over this period, 123,132 health facilities were equipped with RDTs and 137,140 health personnel had been trained to perform RDT examinations. In 2009 and 2010, 41 million RDTs and 136 million ACTs were purchased. The ratio of procured RDTs to ACTs was 0.26 in 2009 and 0.34 in 2010. Conclusions/significance Global Fund financing has enabled 81 malaria-endemic countries to adopt WHO guidelines by investing in RDTs for malaria diagnosis, thereby helping improve case management of acute febrile illness in children. However, roll-out of parasitological diagnosis lags behind the roll-out of ACT-based treatment, and will require prioritization of investments. PMID:22952703

  2. Diagnosing systemic lupus erythematosus: new-generation immunoassays for measurement of anti-dsDNA antibodies are an effective alternative to the Farr technique and the Crithidia luciliae immunofluorescence test.

    PubMed

    Antico, A; Platzgummer, S; Bassetti, D; Bizzaro, N; Tozzoli, R; Villalta, D

    2010-07-01

    The aim of this study was to evaluate the diagnostic performance of four new enzyme immunoassays (EIAs) for anti-double-stranded-DNA (anti-dsDNA) antibodies, in comparison with the Farr assay and the Crithidia luciliae immunofluorescence test (CLIFT). To this purpose, sera from four patient groups were collected: 52 sera from patients with systemic lupus erythematosus (SLE); 28 from patients with other connective tissue diseases (CTD); 36 from patients with hepatitis C virus (HCV) infection; and 24 from those with acute viral infection. All sera were tested for anti-dsDNA antibodies by four EIA methods using a different antigenic DNA source [synthetic oligonucleotide (Method A), circular plasmid (Method B), recombinant (Method C), and purified extracted (Method D)], and by CLIFT and Farr assays. The diagnostic sensitivity of the assays was as follows: 84.6% (Method A), 73% (B), 82.7% (C), 84.6% (D), 55.8% (CLIFT), and 78.8% (Farr). Specificity was 82.9% (A), 97.7% (B), 96.5% (C), 94.3% (D), 96.5% (CLIFT), and 90.9% (Farr). From these data, we can conclude that the new-generation EIA methods evaluated in this study have higher sensitivity than the CLIFT and Farr assays and, with the exception of Method A, have specificity similar to the CLIFT and slightly higher than the Farr assay. These findings suggest that EIA tests may replace CLIFT as a screening test and the Farr assay as a specific test, for anti-dsDNA antibody detection.

  3. 42 CFR 415.180 - Teaching setting requirements for the interpretation of diagnostic radiology and other diagnostic...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... interpretation of diagnostic radiology and other diagnostic tests. 415.180 Section 415.180 Public Health CENTERS... for the interpretation of diagnostic radiology and other diagnostic tests. (a) General rule. Physician fee schedule payment is made for the interpretation of diagnostic radiology and other diagnostic tests...

  4. 42 CFR 415.180 - Teaching setting requirements for the interpretation of diagnostic radiology and other diagnostic...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... interpretation of diagnostic radiology and other diagnostic tests. 415.180 Section 415.180 Public Health CENTERS... for the interpretation of diagnostic radiology and other diagnostic tests. (a) General rule. Physician fee schedule payment is made for the interpretation of diagnostic radiology and other diagnostic tests...

  5. MPT64 antigen detection test improves routine diagnosis of extrapulmonary tuberculosis in a low-resource setting: A study from the tertiary care hospital in Zanzibar.

    PubMed

    Jørstad, Melissa Davidsen; Marijani, Msafiri; Dyrhol-Riise, Anne Ma; Sviland, Lisbet; Mustafa, Tehmina

    2018-01-01

    Extrapulmonary tuberculosis (EPTB) is a diagnostic challenge. An immunochemistry-based MPT64 antigen detection test (MPT64 test) has reported higher sensitivity in the diagnosis of EPTB compared with conventional methods. The objective of this study was to implement and evaluate the MPT64 test in routine diagnostics in a low-resource setting. Patients with presumptive EPTB were prospectively enrolled at Mnazi Mmoja Hospital, Zanzibar, and followed to the end of treatment. Specimens collected were subjected to routine diagnostics, GeneXpert® MTB/RIF assay and the MPT64 test. The performance of the MPT64 test was assessed using a composite reference standard, defining the patients as tuberculosis (TB) cases or non-TB cases. Patients (n = 132) were classified as confirmed TB (n = 12), probable TB (n = 34), possible TB (n = 18), non-TB (n = 62) and uncategorized (n = 6) cases. Overall, in comparison to the composite reference standard for diagnosis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the MPT64 test was 69%, 95%, 94%, 75% and 82%, respectively. The MPT64 test performance was best in TB lymphadenitis cases (n = 67, sensitivity 79%, specificity 97%) and in paediatric TB (n = 41, sensitivity 100%, specificity 96%). We show that the MPT64 test can be implemented in routine diagnostics in a low-resource setting and improves the diagnosis of EPTB, especially in TB lymphadenitis and in children.

  6. Automatic item generation implemented for measuring artistic judgment aptitude.

    PubMed

    Bezruczko, Nikolaus

    2014-01-01

    Automatic item generation (AIG) is a broad class of methods that are being developed to address psychometric issues arising from internet and computer-based testing. In general, issues emphasize efficiency, validity, and diagnostic usefulness of large scale mental testing. Rapid prominence of AIG methods and their implicit perspective on mental testing is bringing painful scrutiny to many sacred psychometric assumptions. This report reviews basic AIG ideas, then presents conceptual foundations, image model development, and operational application to artistic judgment aptitude testing.

  7. Applying team-based learning of diagnostics for undergraduate students: assessing teaching effectiveness by a randomized controlled trial study

    PubMed Central

    Zeng, Rui; Xiang, Lian-rui; Zeng, Jing; Zuo, Chuan

    2017-01-01

    Background We aimed to introduce team-based learning (TBL) as one of the teaching methods for diagnostics and to compare its teaching effectiveness with that of the traditional teaching methods. Methods We conducted a randomized controlled trial on diagnostics teaching involving 111 third-year medical undergraduates, using TBL as the experimental intervention, compared with lecture-based learning as the control, for teaching the two topics of symptomatology. Individual Readiness Assurance Test (IRAT)-baseline and Group Readiness Assurance Test (GRAT) were performed in members of each TBL subgroup. The scores in Individual Terminal Test 1 (ITT1) immediately after class and Individual Terminal Test 2 (ITT2) 1 week later were compared between the two groups. The questionnaire and interview were also implemented to survey the attitude of students and teachers toward TBL. Results There was no significant difference between the two groups in ITT1 (19.85±4.20 vs 19.70±4.61), while the score of the TBL group was significantly higher than that of the control group in ITT2 (19.15±3.93 vs 17.46±4.65). In the TBL group, the scores of the two terminal tests after the teaching intervention were significantly higher than the baseline test score of individuals. IRAT-baseline, ITT1, and ITT2 scores of students at different academic levels in the TBL teaching exhibited significant differences, but the ITT1-IRAT-baseline and ITT2-IRAT-baseline indicated no significant differences among the three subgroups. Conclusion Our TBL in symptomatology approach was highly accepted by students in the improvement of interest and self-directed learning and resulted in an increase in knowledge acquirements, which significantly improved short-term test scores compared with lecture-based learning. TBL is regarded as an effective teaching method worthy of promoting. PMID:28331383

  8. Application of loop-mediated isothermal amplification (LAMP) assays for the detection of bovine herpesvirus 1.

    PubMed

    Socha, W; Rola, J; Urban-Chmiel, R; Żmudziński, J F

    2017-09-26

    Bovine herpesvirus-1 (BoHV-1), a causative agent of Infectious Bovine Rhinotracheitis (IBR), is responsible for high economic losses in cattle farming industry. The use of testing methods that allow early detection of BoHV-1-infected animals is a key element of each program of IBR eradication. The aim of the study was to design and evaluate two variants of LAMP isothermal tests with SYBR Green fluorescence probes, specific to the genes encoding gD and gE glycoproteins of BoHV-1. LAMP gE BoHV-1 assay was able to distinguish between gE- and gE+ strains of the virus. Both LAMP gD and gE assays were specific to BoHV-1 and did not react with other related to BoHV-1 alphaherpesviruses. Sensitivity of LAMP gD was 2x104 copies of the viral genome whereas for LAMP gE it was 2x105. Diagnostic sensitivity calculated for LAMP gD was 64.7% whereas for LAMP gE it was 80%. Diagnostic specificity for LAMP gD and LAMP gE was 78.9% and 89.3%, respectively. LAMP assay can be a rapid and simple method of diagnosis of acute BoHV-1 infections and discrimination of gE- strains. However, relatively low diagnostic sensitivity of the method can limit its use in routine diagnostics.

  9. German Ethics Council on genetic diagnostics: trend setting?

    PubMed

    Buechner, Bianca

    2014-06-01

    On 30 April 2013, the German Ethics Council ('Council') published its opinion on 'The future of genetic diagnostics--from research to clinical application' ('the Opinion'). The Council was asked by the German government to discuss the future of genetic diagnostic methods in relation to the current applicable laws and regulations as well as the ethical stand points. The Council's 23 recommendations show that the existing regulations in Germany, and indirectly on a European level, lack in protecting consumers sufficiently. Consumer protection built the major focus of the Council's opinion. However, the opinion misses a critical overall analysis of genetic testing and, for example, the potential misuse of genetic test results by insures or the risk of disclosure toward employers. The Council missed an opportunity to discuss which barriers are necessary from a legal and ethical perspective but which still do not prohibit genetic testing and research.

  10. Molecular Methods and Platforms for Infectious Diseases Testing

    PubMed Central

    Emmadi, Rajyasree; Boonyaratanakornkit, Jerry B.; Selvarangan, Rangaraj; Shyamala, Venkatakrishna; Zimmer, Barbara L.; Williams, Laurina; Bryant, Bonita; Schutzbank, Ted; Schoonmaker, Michele M.; Amos Wilson, Jean A.; Hall, Leslie; Pancholi, Preeti; Bernard, Kathryn

    2011-01-01

    The superior sensitivity and specificity associated with the use of molecular assays has greatly improved the field of infectious disease diagnostics by providing clinicians with results that are both accurate and rapidly obtained. Herein, we review molecularly based infectious disease diagnostic tests that are Food and Drug Administration approved or cleared and commercially available in the United States as of December 31, 2010. We describe specific assays and their performance, as stated in the Food and Drug Administration's Summary of Safety and Effectiveness Data or the Office of In Vitro Diagnostic Device Evaluation and Safety's decision summaries, product inserts, or peer-reviewed literature. We summarize indications for testing, limitations, and challenges related to implementation in a clinical laboratory setting for a wide variety of common pathogens. The information presented in this review will be particularly useful for laboratories that plan to implement or expand their molecular offerings in the near term. PMID:21871973

  11. Diagnosis of Helicobacter pylori infection: Current options and developments

    PubMed Central

    Wang, Yao-Kuang; Kuo, Fu-Chen; Liu, Chung-Jung; Wu, Meng-Chieh; Shih, Hsiang-Yao; Wang, Sophie SW; Wu, Jeng-Yih; Kuo, Chao-Hung; Huang, Yao-Kang; Wu, Deng-Chyang

    2015-01-01

    Accurate diagnosis of Helicobacter pylori (H. pylori) infection is a crucial part in the effective management of many gastroduodenal diseases. Several invasive and non-invasive diagnostic tests are available for the detection of H. pylori and each test has its usefulness and limitations in different clinical situations. Although none can be considered as a single gold standard in clinical practice, several techniques have been developed to give the more reliable results. Invasive tests are performed via endoscopic biopsy specimens and these tests include histology, culture, rapid urease test as well as molecular methods. Developments of endoscopic equipment also contribute to the real-time diagnosis of H. pylori during endoscopy. Urea breathing test and stool antigen test are most widely used non-invasive tests, whereas serology is useful in screening and epidemiological studies. Molecular methods have been used in variable specimens other than gastric mucosa. More than detection of H. pylori infection, several tests are introduced into the evaluation of virulence factors and antibiotic sensitivity of H. pylori, as well as screening precancerous lesions and gastric cancer. The aim of this article is to review the current options and novel developments of diagnostic tests and their applications in different clinical conditions or for specific purposes. PMID:26523098

  12. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network

    PubMed Central

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-01

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method. PMID:26761006

  13. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network.

    PubMed

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-08

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method.

  14. Usefulness of component resolved analysis of cat allergy in routine clinical practice.

    PubMed

    Eder, Katharina; Becker, Sven; San Nicoló, Marion; Berghaus, Alexander; Gröger, Moritz

    2016-01-01

    Cat allergy is of great importance, and its prevalence is increasing worldwide. Cat allergens and house dust mite allergens represent the major indoor allergens; however, they are ubiquitous. Cat sensitization and allergy are known risk factors for rhinitis, bronchial hyperreactivity and asthma. Thus, the diagnosis of sensitization to cats is important for any allergist. 70 patients with positive skin prick tests for cats were retrospectively compared regarding their skin prick test results, as well as their specific immunoglobulin E antibody profiles with regard to their responses to the native cat extract, rFel d 1, nFel d 2 and rFel d 4. 35 patients were allergic to cats, as determined by positive anamnesis and/or nasal provocation with cat allergens, and 35 patients exhibited clinically non-relevant sensitization, as indicated by negative anamnesis and/or a negative nasal allergen challenge. Native cat extract serology testing detected 100% of patients who were allergic to cats but missed eight patients who showed sensitization in the skin prick test and did not have allergic symptoms. The median values of the skin prick test, as well as those of the specific immunoglobulin E antibodies against the native cat extract, were significantly higher for allergic patients than for patients with clinically non-relevant sensitization. Component based diagnostic testing to rFel d 1 was not as reliable. Sensitization to nFel d 2 and rFel d 4 was seen only in individual patients. Extract based diagnostic methods for identifying cat allergy and sensitization, such as the skin prick test and native cat extract serology, remain crucial in routine clinical practice. In our study, component based diagnostic testing could not replace these methods with regard to the detection of sensitization to cats and differentiation between allergy and sensitization without clinical relevance. However, component resolved allergy diagnostic tools have individual implications, and future studies may facilitate a better understanding of its use and subsequently may improve the clinical management of allergic patients.

  15. Screening for Wilson disease in acute liver failure: a comparison of currently available diagnostic tests.

    PubMed

    Korman, Jessica D; Volenberg, Irene; Balko, Jody; Webster, Joe; Schiodt, Frank V; Squires, Robert H; Fontana, Robert J; Lee, William M; Schilsky, Michael L

    2008-10-01

    Acute liver failure (ALF) due to Wilson disease (WD) is invariably fatal without emergency liver transplantation. Therefore, rapid diagnosis of WD should aid prompt transplant listing. To identify the best method for diagnosis of ALF due to WD (ALF-WD), data and serum were collected from 140 ALF patients (16 with WD), 29 with other chronic liver diseases and 17 with treated chronic WD. Ceruloplasmin (Cp) was measured by both oxidase activity and nephelometry and serum copper levels by atomic absorption spectroscopy. In patients with ALF, a serum Cp <20 mg/dL by the oxidase method provided a diagnostic sensitivity of 21% and specificity of 84% while, by nephelometry, a sensitivity of 56% and specificity of 63%. Serum copper levels exceeded 200 microg/dL in all ALF-WD patients measured (13/16), but were also elevated in non-WD ALF. An alkaline phosphatase (AP) to total bilirubin (TB) ratio <4 yielded a sensitivity of 94%, specificity of 96%, and a likelihood ratio of 23 for diagnosing fulminant WD. In addition, an AST:ALT ratio >2.2 yielded a sensitivity of 94%, a specificity of 86%, and a likelihood ratio of 7 for diagnosing fulminant WD. Combining the tests provided a diagnostic sensitivity and specificity of 100%. Conventional WD testing utilizing serum ceruloplasmin and/or serum copper levels are less sensitive and specific in identifying patients with ALF-WD than other available tests. More readily available laboratory tests including alkaline phosphatase, bilirubin and serum aminotransferases by contrast provides the most rapid and accurate method for diagnosis of ALF due to WD.

  16. Trade-offs in Cervical Cancer Prevention: Balancing Benefits and Risks

    PubMed Central

    Stout, Natasha K.; Goldhaber-Fiebert, Jeremy D.; Ortendahl, Jesse D.; Goldie, Sue J.

    2009-01-01

    Background New screening and vaccination technologies will provide women with more options for cervical cancer prevention. Because the risk of cervical cancer diminishes with effective routine screening, women may wish to consider additional attributes, such as the likelihood of false-positive results and diagnostic procedures for mild abnormalities likely to resolve without intervention in their screening choices. Methods We used an empirically calibrated simulation model of cervical cancer in the United States to assess the benefits and potential risks associated with prevention strategies differing by primary screening test, triage test for abnormal results (cytologic testing, human papillomavirus [HPV] DNA test), and screening frequency. Outcomes included colposcopy referrals, cervical intraepithelial neoplasia (CIN) types 1 and 2 or 3, lifetime cancer risk, and quality-adjusted life expectancy. Results Across strategies, colposcopy referrals and diagnostic workups varied 3-fold, although diagnostic rates of CIN 2 or 3 were similar and 95% of positive screening test results were for mild abnormalities likely to resolve on their own. For a representative group of a thousand 20-year-old women undergoing triennial screening for 10 years, we expect 1038 colposcopy referrals (7 CIN 2 or 3 diagnoses) from combined cytologic and HPV DNA testing and fewer than 200 referrals (6–7 CIN 2 or 3 diagnoses) for strategies that use triage testing. Similarly, for a thousand 40-year-old women, combined cytologic and HPV DNA testing led to 489 referrals (9 CIN 2 or 3), whereas alternative strategies resulted in fewer than 150 referrals (7–8 CIN 2 or 3). Using cytologic testing followed by triage testing in younger women minimizes both diagnostic workups and positive HPV test results, whereas in older women diagnostic workups are minimized with HPV DNA testing followed by cytologic triage testing. Conclusions Clinically relevant information highlighting trade-offs among cervical cancer prevention strategies allows for inclusion of personal preferences into women’s decision making about screening and provides additional dimensions to the construction of clinical guidelines. PMID:18809815

  17. The impact of commercial rapid respiratory virus diagnostic tests on patient outcomes and health system utilization.

    PubMed

    Ko, Fiona; Drews, Steven J

    2017-10-01

    Acute respiratory tract infections due to influenza A/B and respiratory syncytial virus (RSV) are major causes of morbidity and mortality globally. Rapid tests for detection of these pathogens include antigen detection point of care tests (POC) and newer easy to use molecular tests. From experience, these assays improve both laboratory workflow and assay interpretation issues. However, the question of the benefits of using rapid test technology compared to routine laboratory testing for respiratory viral pathogens is still often asked. Areas covered: Specifically, this review aims to; 1) identify clinical/patient indicators that can be measured prior to and following the implementation of rapid diagnostic test for influenza and RSV, 2) provide multiple perspectives on the extent of impact of a rapid diagnostic test, including direct and indirect outcomes, and 3) identify the technological advancements in the development of rapid testing, demonstrating a timeline that transitions from antigen-based assays to molecular assays. Expert commentary: Key benefits to the use of either antigen-based or molecular rapid tests for patient care, patient flow within institutions, as well as laboratory utilization are identified. Due to improved test characteristics, the authors feel that rapid molecular tests have greater benefits than antigen-based detection methods.

  18. Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy

    PubMed Central

    Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum

    2017-01-01

    Background: The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. Objectives: The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Design: Retrospective study. Methods: Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. Results: The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% (P < 0.0001); specificity, 98.53% and 86.76% (P = 0.0026); accuracy, 77.04% and 85.93% (P = 0.0423), respectively. Conclusions: The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test. PMID:28824298

  19. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  20. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  1. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  2. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  3. 21 CFR 660.45 - Labeling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Hepatitis B Surface Antigen § 660.45 Labeling. In... capable of transmitting hepatitis and should be handled accordingly. (d) The package shall include a... test methods, and (3) warnings as to possible hazards, including hepatitis transmitted in handling the...

  4. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health.

    PubMed

    Miller, Eric; Sikes, Hadley D

    Immunochromatographic rapid diagnostic tests (RDTs) have demonstrated significant potential for use as point-of-care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs.

  5. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health

    PubMed Central

    Miller, Eric; Sikes, Hadley D.

    2015-01-01

    Immunochromatographic rapid diagnostic tests (RDTs) have demonstrated significant potential for use as point-of-care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs. PMID:26594252

  6. Optimizing Patient-centered Communication and Multidisciplinary Care Coordination in Emergency Diagnostic Imaging: A Research Agenda.

    PubMed

    Sabbatini, Amber K; Merck, Lisa H; Froemming, Adam T; Vaughan, William; Brown, Michael D; Hess, Erik P; Applegate, Kimberly E; Comfere, Nneka I

    2015-12-01

    Patient-centered emergency diagnostic imaging relies on efficient communication and multispecialty care coordination to ensure optimal imaging utilization. The construct of the emergency diagnostic imaging care coordination cycle with three main phases (pretest, test, and posttest) provides a useful framework to evaluate care coordination in patient-centered emergency diagnostic imaging. This article summarizes findings reached during the patient-centered outcomes session of the 2015 Academic Emergency Medicine consensus conference "Diagnostic Imaging in the Emergency Department: A Research Agenda to Optimize Utilization." The primary objective was to develop a research agenda focused on 1) defining component parts of the emergency diagnostic imaging care coordination process, 2) identifying gaps in communication that affect emergency diagnostic imaging, and 3) defining optimal methods of communication and multidisciplinary care coordination that ensure patient-centered emergency diagnostic imaging. Prioritized research questions provided the framework to define a research agenda for multidisciplinary care coordination in emergency diagnostic imaging. © 2015 by the Society for Academic Emergency Medicine.

  7. Methods in virus diagnostics: from ELISA to next generation sequencing.

    PubMed

    Boonham, Neil; Kreuze, Jan; Winter, Stephan; van der Vlugt, René; Bergervoet, Jan; Tomlinson, Jenny; Mumford, Rick

    2014-06-24

    Despite the seemingly continuous development of newer and ever more elaborate methods for detecting and identifying viruses, very few of these new methods get adopted for routine use in testing laboratories, often despite the many and varied claimed advantages they possess. To understand why the rate of uptake of new technologies is so low, requires a strong understanding of what makes a good routine diagnostic tool to begin. This can be done by looking at the two most successfully established plant virus detection methods: enzyme-linked immunosorbant assay (ELISA) and more recently introduced real-time polymerase chain reaction (PCR). By examining the characteristics of this pair of technologies, it becomes clear that they share many benefits, such as an industry standard format and high levels of repeatability and reproducibility. These combine to make methods that are accessible to testing labs, which are easy to establish and robust in their use, even with new and inexperienced users. Hence, to ensure the establishment of new techniques it is necessary to not only provide benefits not found with ELISA or real-time PCR, but also to provide a platform that is easy to establish and use. In plant virus diagnostics, recent developments can be clustered into three core areas: (1) techniques that can be performed in the field or resource poor locations (e.g., loop-mediated isothermal amplification LAMP); (2) multiplex methods that are able to detect many viruses in a single test (e.g., Luminex bead arrays); and (3) methods suited to virus discovery (e.g., next generation sequencing, NGS). Field based methods are not new, with Lateral Flow Devices (LFDs) for the detection being available for a number of years now. However, the widespread uptake of this technology remains poor. LAMP does offer significant advantages over LFDs, in terms of sensitivity and generic application, but still faces challenges in terms of establishment. It is likely that the main barrier to the uptake of field-based technologies is behavioural influences, rather than specific concerns about the performance of the technologies themselves. To overcome this, a new relationship will need to develop between centralised testing laboratories offering services and those requiring tests; a relationship which is currently in its infancy. Looking further into the future, virus discovery and multiplex methods seem to converge as NGS becomes ever cheaper, easier to perform and can provide high levels of multiplexing without the use of virus specific reagents. So ultimately the key challenge from a routine testing lab perspective will not be one of investment in platforms-which could even be outsourced to commercial sequencing services-but one of having the skills and expertise to analyse the large datasets generated and their subsequent interpretation. In conclusion, only time will tell which of the next-generation of methods currently in development will become the routine diagnostics of the future. This will be determined through a combination of factors. And while the technology itself will have to offer performance advantages over existing methods in order to supplant them, it is likely to be human factors e.g., the behaviours of end users, laboratories and policy makers, the availability of appropriate expertise, that ultimately determine which ones become established. Hence factors cannot be ignored and early engagement with diagnostic stakeholders is essential. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  8. A fast Monte Carlo EM algorithm for estimation in latent class model analysis with an application to assess diagnostic accuracy for cervical neoplasia in women with AGC

    PubMed Central

    Kang, Le; Carter, Randy; Darcy, Kathleen; Kauderer, James; Liao, Shu-Yuan

    2013-01-01

    In this article we use a latent class model (LCM) with prevalence modeled as a function of covariates to assess diagnostic test accuracy in situations where the true disease status is not observed, but observations on three or more conditionally independent diagnostic tests are available. A fast Monte Carlo EM (MCEM) algorithm with binary (disease) diagnostic data is implemented to estimate parameters of interest; namely, sensitivity, specificity, and prevalence of the disease as a function of covariates. To obtain standard errors for confidence interval construction of estimated parameters, the missing information principle is applied to adjust information matrix estimates. We compare the adjusted information matrix based standard error estimates with the bootstrap standard error estimates both obtained using the fast MCEM algorithm through an extensive Monte Carlo study. Simulation demonstrates that the adjusted information matrix approach estimates the standard error similarly with the bootstrap methods under certain scenarios. The bootstrap percentile intervals have satisfactory coverage probabilities. We then apply the LCM analysis to a real data set of 122 subjects from a Gynecologic Oncology Group (GOG) study of significant cervical lesion (S-CL) diagnosis in women with atypical glandular cells of undetermined significance (AGC) to compare the diagnostic accuracy of a histology-based evaluation, a CA-IX biomarker-based test and a human papillomavirus (HPV) DNA test. PMID:24163493

  9. Infection with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance--Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2012-2015.

    PubMed

    Huang, Jennifer Y; Henao, Olga L; Griffin, Patricia M; Vugia, Duc J; Cronquist, Alicia B; Hurd, Sharon; Tobin-D'Angelo, Melissa; Ryan, Patricia; Smith, Kirk; Lathrop, Sarah; Zansky, Shelley; Cieslak, Paul R; Dunn, John; Holt, Kristin G; Wolpert, Beverly J; Patrick, Mary E

    2016-04-15

    To evaluate progress toward prevention of enteric and foodborne illnesses in the United States, the Foodborne Diseases Active Surveillance Network (FoodNet) monitors the incidence of laboratory-confirmed infections caused by nine pathogens transmitted commonly through food in 10 U.S. sites. This report summarizes preliminary 2015 data and describes trends since 2012. In 2015, FoodNet reported 20,107 confirmed cases (defined as culture-confirmed bacterial infections and laboratory-confirmed parasitic infections), 4,531 hospitalizations, and 77 deaths. FoodNet also received reports of 3,112 positive culture-independent diagnostic tests (CIDTs) without culture-confirmation, a number that has markedly increased since 2012. Diagnostic testing practices for enteric pathogens are rapidly moving away from culture-based methods. The continued shift from culture-based methods to CIDTs that do not produce the isolates needed to distinguish between strains and subtypes affects the interpretation of public health surveillance data and ability to monitor progress toward prevention efforts. Expanded case definitions and strategies for obtaining bacterial isolates are crucial during this transition period.

  10. Sample size for positive and negative predictive value in diagnostic research using case–control designs

    PubMed Central

    Steinberg, David M.; Fine, Jason; Chappell, Rick

    2009-01-01

    Important properties of diagnostic methods are their sensitivity, specificity, and positive and negative predictive values (PPV and NPV). These methods are typically assessed via case–control samples, which include one cohort of cases known to have the disease and a second control cohort of disease-free subjects. Such studies give direct estimates of sensitivity and specificity but only indirect estimates of PPV and NPV, which also depend on the disease prevalence in the tested population. The motivating example arises in assay testing, where usage is contemplated in populations with known prevalences. Further instances include biomarker development, where subjects are selected from a population with known prevalence and assessment of PPV and NPV is crucial, and the assessment of diagnostic imaging procedures for rare diseases, where case–control studies may be the only feasible designs. We develop formulas for optimal allocation of the sample between the case and control cohorts and for computing sample size when the goal of the study is to prove that the test procedure exceeds pre-stated bounds for PPV and/or NPV. Surprisingly, the optimal sampling schemes for many purposes are highly unbalanced, even when information is desired on both PPV and NPV. PMID:18556677

  11. [The Diagnostics of Detonation Flow External Field Based on Multispectral Absorption Spectroscopy Technology].

    PubMed

    Lü, Xiao-jing; Li, Ning; Weng, Chun-sheng

    2016-03-01

    Compared with traditional sampling-based sensing method, absorption spectroscopy technology is well suitable for detonation flow diagnostics, since it can provide with us fast response, nonintrusive, sensitive solution for situ measurements of multiple flow-field parameters. The temperature and concentration test results are the average values along the laser path with traditional absorption spectroscopy technology, while the boundary of detonation flow external field is unknown and it changes all the time during the detonation engine works, traditional absorption spectroscopy technology is no longer suitable for detonation diagnostics. The trend of line strength with temperature varies with different absorption lines. By increasing the number of absorption lines in the test path, more information of the non-uniform flow field can be obtained. In this paper, based on multispectral absorption technology, the reconstructed model of detonation flow external field distribution was established according to the simulation results of space-time conservation element and solution element method, and a diagnostic method of detonation flow external field was given. The model deviation and calculation error of the least squares method adopted were studied by simulation, and the maximum concentration and temperature calculation error was 20.1% and 3.2%, respectively. Four absorption lines of H2O were chosen and detonation flow was scanned at the same time. The detonation external flow testing system was set up for the valveless gas-liquid continuous pulse detonation engine with the diameter of 80 mm. Through scanning H2O absorption lines with a high frequency of 10 kHz, the on-line detection of detonation external flow was realized by direct absorption method combined with time-division multiplexing technology, and the reconstruction of dynamic temperature distribution was realized as well for the first time, both verifying the feasibility of the test method. The test results show that both of the temperature and H2O concentration rose with the arrival of detonation wave. With the increase of the vertical distance between the detonation tube nozzle and the laser path, the time of temperature and concentration coming to the peak delayed, and the temperature variation trend tended to slow down. At 20 cm from detonation tube nozzle, the maximum temperature hit 1 329 K and the maximum H2O concentration of 0.19 occurred at 4 ms after ignition. The research can provide with us the support for expanding the detonation test field with absorption spectroscopy technology, and can also help to promote the detonation mechanism research and to enhance the level of detonation engine control technology.

  12. Atomic Resonance Radiation Energetics Investigation as a Diagnostic Method for Non-Equilibrium Hypervelocity Flows

    NASA Technical Reports Server (NTRS)

    Meyer, Scott A.; Bershader, Daniel; Sharma, Surendra P.; Deiwert, George S.

    1996-01-01

    Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.

  13. [Peculiarities of the early diagnostics of malignant nasopharyngal neoplasms].

    PubMed

    Baryshev, V V; Andreev, V G; Sevryukov, F E; Buyakova, M E; Akki, E D

    The authors consider the risk factors and the specific clinical symptoms of the malignant nasopharyngal neoplasms as well as the methods for instrumental, laboratory, and pathomorphological diagnostics of this pathology. The full scale implementation of the recommendations for the timely detection of the tumours using the aforementioned diagnostic procedures and tests makes it possible to reduce to a minimum the interval between the establishment of the diagnosis and the onset of the relevant treatment at the early stages of the disease and thereby to ensure the improvement of its long-term outcomes.

  14. Fan fault diagnosis based on symmetrized dot pattern analysis and image matching

    NASA Astrophysics Data System (ADS)

    Xu, Xiaogang; Liu, Haixiao; Zhu, Hao; Wang, Songling

    2016-07-01

    To detect the mechanical failure of fans, a new diagnostic method based on the symmetrized dot pattern (SDP) analysis and image matching is proposed. Vibration signals of 13 kinds of running states are acquired on a centrifugal fan test bed and reconstructed by the SDP technique. The SDP pattern templates of each running state are established. An image matching method is performed to diagnose the fault. In order to improve the diagnostic accuracy, the single template, multiple templates and clustering fault templates are used to perform the image matching.

  15. Test-treatment RCTs are susceptible to bias: a review of the methodological quality of randomized trials that evaluate diagnostic tests.

    PubMed

    Ferrante di Ruffano, Lavinia; Dinnes, Jacqueline; Sitch, Alice J; Hyde, Chris; Deeks, Jonathan J

    2017-02-24

    There is a growing recognition for the need to expand our evidence base for the clinical effectiveness of diagnostic tests. Many international bodies are calling for diagnostic randomized controlled trials to provide the most rigorous evidence of impact to patient health. Although these so-called test-treatment RCTs are very challenging to undertake due to their methodological complexity, they have not been subjected to a systematic appraisal of their methodological quality. The extent to which these trials may be producing biased results therefore remains unknown. We set out to address this issue by conducting a methodological review of published test-treatment trials to determine how often they implement adequate methods to limit bias and safeguard the validity of results. We ascertained all test-treatment RCTs published 2004-2007, indexed in CENTRAL, including RCTs which randomized patients to diagnostic tests and measured patient outcomes after treatment. Tests used for screening, monitoring or prognosis were excluded. We assessed adequacy of sequence generation, allocation concealment and intention-to-treat, appropriateness of primary analyses, blinding and reporting of power calculations, and extracted study characteristics including the primary outcome. One hundred three trials compared 105 control with 119 experimental interventions, and reported 150 primary outcomes. Randomization and allocation concealment were adequate in 57 and 37% of trials. Blinding was uncommon (patients 5%, clinicians 4%, outcome assessors 21%), as was an adequate intention-to-treat analysis (29%). Overall 101 of 103 trials (98%) were at risk of bias, as judged using standard Cochrane criteria. Test-treatment trials are particularly susceptible to attrition and inadequate primary analyses, lack of blinding and under-powering. These weaknesses pose much greater methodological and practical challenges to conducting reliable RCT evaluations of test-treatment strategies than standard treatment interventions. We suggest a cautious approach that first examines whether a test-treatment intervention can accommodate the methodological safeguards necessary to minimize bias, and highlight that test-treatment RCTs require different methods to ensure reliability than standard treatment trials. Please see the companion paper to this article: http://bmcmedresmethodol.biomedcentral.com/articles/10.1186/s12874-016-0286-0 .

  16. A combined strategy for screening a clustered mobile population returning from highly endemic areas for Plasmodium falciparum.

    PubMed

    Li, Mei; Li, Jun; Xia, Zhigui; Xiao, Ning; Jiang, Weikang; Wen, Yongkang

    2017-04-30

    Early and accurate diagnosis of imported malaria cases in clusters is crucial for protecting the health of patients and local populations, especially confirmed parasitic persons who are asymptomatic. A total of 226 gold miners who had stayed in highly endemic areas of Ghana for more than six months and returned in clusters were selected randomly. Blood samples from them were tested with microscopy, nest polymerase chain reaction, and rapid diagnostic test (RDT). The sensitivity, specificity, predictive values, agreement rate, and Youden's index of each of three diagnostic methods were calculated and compared with the defined gold standard. A quick and efficient way to respond to screening such a clustered mobile population was predicted and analyzed by evaluating two assumed results of combining microscopy and RDT with or without symptoms of illness. The rate of the carriers of malaria parasites in the populations of gold miners was 19.47%, including 39 P. falciparum. Among the three diagnostic methods, the microscopy method showed the highest specificity, while the RDT method showed the highest sensitivity but the lowest specificity in detecting P. falciparum. The assumed results of combining RDT and microscopy with symptoms showed the best results among all the test results in screening P. falciparum. It was too complex and difficult to catch all parasite carriers in a short period of time among populations with such a complicated situation as that in Shanglin County. A strategy of combing microscopy and RDT for diagnosis is highly recommended.

  17. Evaluating a mobile application for improving clinical laboratory test ordering and diagnosis.

    PubMed

    Meyer, Ashley N D; Thompson, Pamela J; Khanna, Arushi; Desai, Samir; Mathews, Benji K; Yousef, Elham; Kusnoor, Anita V; Singh, Hardeep

    2018-04-20

    Mobile applications for improving diagnostic decision making often lack clinical evaluation. We evaluated if a mobile application improves generalist physicians' appropriate laboratory test ordering and diagnosis decisions and assessed if physicians perceive it as useful for learning. In an experimental, vignette study, physicians diagnosed 8 patient vignettes with normal prothrombin times (PT) and abnormal partial thromboplastin times (PTT). Physicians made test ordering and diagnosis decisions for 4 vignettes using each resource: a mobile app, PTT Advisor, developed by the Centers for Disease Control and Prevention (CDC)'s Clinical Laboratory Integration into Healthcare Collaborative (CLIHC); and usual clinical decision support. Then, physicians answered questions regarding their perceptions of the app's usefulness for diagnostic decision making and learning using a modified Kirkpatrick Training Evaluation Framework. Data from 368 vignettes solved by 46 physicians at 7 US health care institutions show advantages for using PTT Advisor over usual clinical decision support on test ordering and diagnostic decision accuracy (82.6 vs 70.2% correct; P < .001), confidence in decisions (7.5 vs 6.3 out of 10; P < .001), and vignette completion time (3:02 vs 3:53 min.; P = .06). Physicians reported positive perceptions of the app's potential for improved clinical decision making, and recommended it be used to address broader diagnostic challenges. A mobile app, PTT Advisor, may contribute to better test ordering and diagnosis, serve as a learning tool for diagnostic evaluation of certain clinical disorders, and improve patient outcomes. Similar methods could be useful for evaluating apps aimed at improving testing and diagnosis for other conditions.

  18. Proband-only medical exome sequencing as a cost-effective first-tier genetic diagnostic test for patients without prior molecular tests and clinical diagnosis in a developing country: the China experience.

    PubMed

    Hu, Xuyun; Li, Niu; Xu, Yufei; Li, Guoqiang; Yu, Tingting; Yao, Ru-En; Fu, Lijun; Wang, Jiwen; Yin, Lei; Yin, Yong; Wang, Ying; Jin, Xingming; Wang, Xiumin; Wang, Jian; Shen, Yiping

    2017-11-02

    PurposeTo evaluate the performance of proband-only medical exome sequencing (POMES) as a cost-effective first-tier diagnostic test for pediatric patients with unselected conditions.MethodsA total of 1,323 patients were tested by POMES, which targeted 2,742 known disease-causing genes. Clinical relevant variants were Sanger-confirmed in probands and parents. We assessed the diagnostic validity and clinical utility of POMES by means of a survey questionnaire.ResultsPOMES, ordered by 136 physicians, identified 512 pathogenic or likely pathogenic variants associated with over 200 conditions. The overall diagnostic rate was 28.8%, ranging from 10% in neonatal intensive care unit patients to over 35% in pediatric intensive care unit patients. The test results had an impact on the management of the 45.1% of patients for whom there were positive findings. The average turnaround time was 57 days; the cost was $360/case.ConclusionWe adopted a relatively efficient and cost-effective approach in China for the molecular diagnosis of pediatric patients with suspected genetic conditions. While training for clinical geneticists and other specialists is lagging behind in China POMES is serving as a diagnostic equalizer for patients who do not normally receive extensive clinical evaluation and clinical diagnosis prior to testing. This Chinese experience should be applicable to other developing countries that are lacking clinical, financial, and personnel resources.GENETICS in MEDICINE advance online publication, 2 November 2017; doi:10.1038/gim.2017.195.

  19. Affirm VPIII microbial identification test can be used to detect gardnerella vaginalis, Candida albicans and trichomonas vaginalis microbial infections in Korean women.

    PubMed

    Byun, Seung Won; Park, Yeon Joon; Hur, Soo Young

    2016-04-01

    The aim of this study was to compare Affirm VPIII Microbial Identification Test results for Korean women to those obtained for Gardnerella vaginalis through Nugent score, Candida albicans based on vaginal culture and Trichomonas vaginalis based on wet smear diagnostic standards. Study participants included 195 women with symptomatic or asymptomatic vulvovaginitis under hospital obstetric or gynecologic care. A definite diagnosis was made based on Nugent score for Gardnerella, vaginal culture for Candida and wet prep for Trichomonas vaginalis. Affirm VPIII Microbial Identification Test results were then compared to diagnostic standard results. Of the 195 participants, 152 were symptomatic, while 43 were asymptomatic. Final diagnosis revealed 68 (37.87%) cases of Gardnerella, 29 (14.87%) cases of Candida, one (0.51%) case of Trichomonas, and 10 (5.10%) cases of mixed infections. The detection rates achieved by each detection method (Affirm assay vs diagnostic standard) for Gardnerella and Candida were not significantly different (33.33% vs 34.8% for Gardnerella, 13.33% vs 14.87% for Candida, respectively). The sensitivity and specificity of the Affirm test for Gardnerella compared to the diagnostic standard were 75.0% and 88.98%, respectively. For Candida, the sensitivity and specificity of the Affirm test compared to the diagnostic standard were 82.76% and 98.80%, respectively. The number of Trichomonas cases was too small (1 case) to be statistically analyzed. The Affirm test is a quick tool that can help physicians diagnose and treat patients with infectious vaginitis at the point of care. © 2016 Japan Society of Obstetrics and Gynecology.

  20. Cost-effective Diagnostic Checklists for Meningitis in Resource Limited Settings

    PubMed Central

    Durski, Kara N.; Kuntz, Karen M.; Yasukawa, Kosuke; Virnig, Beth A.; Meya, David B.; Boulware, David R.

    2013-01-01

    Background Checklists can standardize patient care, reduce errors, and improve health outcomes. For meningitis in resource-limited settings, with high patient loads and limited financial resources, CNS diagnostic algorithms may be useful to guide diagnosis and treatment. However, the cost-effectiveness of such algorithms is unknown. Methods We used decision analysis methodology to evaluate the costs, diagnostic yield, and cost-effectiveness of diagnostic strategies for adults with suspected meningitis in resource limited settings with moderate/high HIV prevalence. We considered three strategies: 1) comprehensive “shotgun” approach of utilizing all routine tests; 2) “stepwise” strategy with tests performed in a specific order with additional TB diagnostics; 3) “minimalist” strategy of sequential ordering of high-yield tests only. Each strategy resulted in one of four meningitis diagnoses: bacterial (4%), cryptococcal (59%), TB (8%), or other (aseptic) meningitis (29%). In model development, we utilized prevalence data from two Ugandan sites and published data on test performance. We validated the strategies with data from Malawi, South Africa, and Zimbabwe. Results The current comprehensive testing strategy resulted in 93.3% correct meningitis diagnoses costing $32.00/patient. A stepwise strategy had 93.8% correct diagnoses costing an average of $9.72/patient, and a minimalist strategy had 91.1% correct diagnoses costing an average of $6.17/patient. The incremental cost effectiveness ratio was $133 per additional correct diagnosis for the stepwise over minimalist strategy. Conclusions Through strategically choosing the order and type of testing coupled with disease prevalence rates, algorithms can deliver more care more efficiently. The algorithms presented herein are generalizable to East Africa and Southern Africa. PMID:23466647

  1. Diagnostic validation of three test methods for detection of cyprinid herpesvirus 3 (CyHV-3).

    PubMed

    Clouthier, Sharon C; McClure, Carol; Schroeder, Tamara; Desai, Megan; Hawley, Laura; Khatkar, Sunita; Lindsay, Melissa; Lowe, Geoff; Richard, Jon; Anderson, Eric D

    2017-03-06

    Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of koi herpesvirus disease in koi and common carp. The disease is notifiable to the World Organisation for Animal Health. Three tests-quantitative polymerase chain reaction (qPCR), conventional PCR (cPCR) and virus isolation by cell culture (VI)-were validated to assess their fitness as diagnostic tools for detection of CyHV-3. Test performance metrics of diagnostic accuracy were sensitivity (DSe) and specificity (DSp). Repeatability and reproducibility were measured to assess diagnostic precision. Estimates of test accuracy, in the absence of a gold standard reference test, were generated using latent class models. Test samples originated from wild common carp naturally exposed to CyHV-3 or domesticated koi either virus free or experimentally infected with the virus. Three laboratories in Canada participated in the precision study. Moderate to high repeatability (81 to 99%) and reproducibility (72 to 97%) were observed for the qPCR and cPCR tests. The lack of agreement observed between some of the PCR test pair results was attributed to cross-contamination of samples with CyHV-3 nucleic acid. Accuracy estimates for the PCR tests were 99% for DSe and 93% for DSp. Poor precision was observed for the VI test (4 to 95%). Accuracy estimates for VI/qPCR were 90% for DSe and 88% for DSp. Collectively, the results show that the CyHV-3 qPCR test is a suitable tool for surveillance, presumptive diagnosis and certification of individuals or populations as CyHV-3 free.

  2. Validation of wet mount microscopy against Trichomonas culture among women of reproductive age group in Western province, Sri Lanka.

    PubMed

    Banneheke, H; Fernandopulle, R; Gunasekara, U; Barua, A; Fernando, N; Wickremasinghe, R

    2015-06-01

    Wet mount microscopy is the most commonly used diagnostic method for trichomoniasis in clinical diagnostic services all over the world including Sri Lanka due to its availability, simplicity and is relatively inexpensive. However, Trichomonas culture and PCR are the gold standard tests. Unfortunately, neither the culture nor PCR is available for the diagnosis of trichomoniasis in Sri Lanka. Thus, it is important to validate the wet mount microscopy as it is the only available diagnostic test and has not been validated to date in Sri Lanka. The objective was to evaluate the validity and reliability of wet mount microscopy against gold standard Trichomonas culture among clinic based population of reproductive age group women in Western province, Sri Lanka. Women attending hospital and institutional based clinics were enrolled. They were interviewed and high vaginal swabs were taken for laboratory diagnosis by culture and wet mount microscopy. There were 601 participants in the age group of 15-45 years. Wet mount microscopy showed 68% sensitivity, 100% specificity, 100% positive (PPV) and 98% negative predictive values (NPV) (P=0.001, kappa=0.803) respectively against the gold standard culture. The area under the ROC curve was 0.840. Sensitivity of wet mount microscopy is low. However it has high validity and reliability as a specific diagnostic test for trichomoniasis. If it is to be used among women of reproductive age group in Western province, Sri Lanka, a culture method could be adopted as a second test to confirm the negative wet mount for symptomatic patients.

  3. A novel orellanine containing mushroom Cortinarius armillatus.

    PubMed

    Shao, Dahai; Tang, Shusheng; Healy, Rosanne A; Imerman, Paula M; Schrunk, Dwayne E; Rumbeiha, Wilson K

    2016-05-01

    Orellanine (3,3',4,4'-tetrahydroxy-2,2'-bipyridine-1,1'-dioxide) is a tetrahydroxylated di-N-oxidized bipyridine compound. The toxin, present in certain species of Cortinarius mushrooms, is structurally similar to herbicides Paraquat and Diquat. Cortinarius orellanus and Cortinarius rubellus are the major orellanine-containing mushrooms. Cortinarius mushrooms are widely reported in Europe where they have caused human poisoning and deaths through accidental ingestion of the poisonous species mistaken for the edible ones. In North America, Cortinarius orellanosus mushroom poisoning was recently reported to cause renal failure in a Michigan patient. Cortinarius mushroom poisoning is characterized by delayed acute renal failure, with some cases progressing to end-stage kidney disease. There is debate whether other Cortinarius mushroom contain orellanine or not, especially in North America. Currently, there are no veterinary diagnostic laboratories in North America with established test methods for detection and quantitation of orellanine. We have developed two diagnostic test methods based on HPLC and LC-MSMS for identification and quantitation of orellanine in mushrooms. Using these methods, we have identified Cortinarius armillatus as a novel orellanine-containing mushroom in North America. The mean toxin concentration of 145 ug/g was <1% of that of the more toxic C. rubellus. The HPLC method can detect orellanine at 17 μg g(-1) while the LC-MSMS method is almost 2000 times more sensitive and can detect orellanine at 30 ng g(-1). Both tests are quantitative, selective and are now available for veterinary diagnostic applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Evaluation of a rapid diagnostic field test kit for identification of Phytophthora ramorum, P. kernoviae and other Phytophthora species at the point of inspection

    Treesearch

    C.R. Lane; E. Hobden; L. Laurenson; V.C. Barton; K.J.D. Hughes; H. Swan; N. Boonham; A.J. Inman

    2008-01-01

    Plant health regulations to prevent the introduction and spread of Phytophthora ramorum and P. kernoviae require rapid, cost effective diagnostic methods for screening large numbers of plant samples at the time of inspection. Current on-site techniques require expensive equipment, considerable expertise and are not suited for plant...

  5. Potential Clinical Impact of The Filmarray Meningitis Encephalitis Panel In Children With Suspected Central Nervous System Infections

    PubMed Central

    Messacar, Kevin; Breazeale, Garrett; Robinson, Christine C.; Dominguez, Samuel R.

    2016-01-01

    The FilmArray Meningitis Encephalitis Panel, a multiplex PCR for testing of cerebrospinal fluid, was compared to conventional diagnostic methods in children with suspected central nervous system infections. The panel had comparable diagnostic yield (96% agreement) and improved time-to-diagnosis by 10.3 hours with potential for more judicious antimicrobial use, particularly acyclovir. PMID:27342782

  6. The evaluation of GM6-based ELISA and ICT as diagnostic methods on a Mongolian farm with an outbreak of non-tsetse transmitted horse trypanosomosis.

    PubMed

    Davaasuren, Batdorj; Amgalanbaatar, Tovuu; Musinguzi, Simon Peter; Suganuma, Keisuke; Otgonsuren, Davaajav; Mossaad, Ehab; Narantsatsral, Sandagdorj; Battur, Banzragch; Battsetseg, Badgar; Xuan, Xuenan; Inoue, Noboru

    2017-09-15

    Trypanosoma equiperdum, which is the etiological agent of dourine, spreads through sexual intercourse in equines. Dourine (T. equiperdum) has been reported in Mongolia, where it is considered an economically important disease of horses. T. evansi has also been reported in Mongolian domestic animals. The objective of this study was to evaluate the potential application of recombinant T. evansi GM6 (rTeGM6-4r)-based diagnostic methods on a farm with an outbreak of non-tsetse transmitted horse trypanosomosis. Ninety-seven percent homology was found between the amino acid sequences of T. equiperdum GM6 and the GM6 of another Trypanozoon, which also shared the same cellular localization. This finding suggests the utility of rTeGM6-4r-based serodiagnostic methods for epidemiological studies and the diagnosis of both surra and dourine in Equidae. Fifty blood samples were examined from a herd of horses. The diagnostic value of an rTeGM6-4r-based ELISA and an rTeGM6-4r-based immunochromatographic test (ICT) were measured in comparison to a T. evansi crude antigen-based ELISA, which is a diagnostic method recommended by the OIE. However, this is not a perfect diagnostic method for trypanosomosis. Positive serum samples were detected in 46%, 42% and 28% of the tested horses using an rTeGM6-4r-based ELISA, crude antigen-based ELISA and rTeGM6-4r-based ICT, respectively. The sensitivity of rTeGM6-based ELISA was 81%, the specificity was 79%, and the agreement was moderate. We conclude that rTeGM6-4r-based ELISA and ICT represent alternative options for baseline epidemiological studies and the on-site diagnosis of horse trypanosomoses in the field, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Small business development for molecular diagnostics.

    PubMed

    Anagostou, Anthanasia; Liotta, Lance A

    2012-01-01

    Molecular profiling, which is the application of molecular diagnostics technology to tissue and blood -specimens, is an integral element in the new era of molecular medicine and individualized therapy. Molecular diagnostics is a fertile ground for small business development because it can generate products that meet immediate demands in the health-care sector: (a) Detection of disease risk, or early-stage disease, with a higher specificity and sensitivity compared to previous testing methods, and (b) "Companion diagnostics" for stratifying patients to receive a treatment choice optimized to their individual disease. This chapter reviews the promise and challenges of business development in this field. Guidelines are provided for the creation of a business model and the generation of a marketing plan around a candidate molecular diagnostic product. Steps to commercialization are outlined using existing molecular diagnostics companies as learning examples.

  8. Feasibility study of structured diagnosis methods for functional dyspepsia in Korean medicine clinics.

    PubMed

    Park, Jeong Hwan; Kim, Soyoung; Park, Jae-Woo; Ko, Seok-Jae; Lee, Sanghun

    2017-12-01

    Functional dyspepsia (FD) is the seventh most common disease encountered in Korean medicine (KM) clinics. Despite the large number of FD patients visiting KM clinics, the accumulated medical records have no utility in evidence development, due to being unstructured. This study aimed to construct a standard operating procedure (SOP) with appropriate structured diagnostic methods for FD, and assess the feasibility for use in KM clinics. Two rounds of professional surveys were conducted by 10 Korean internal medicine professors to select the representative diagnostic methods. A feasibility study was conducted to evaluate compliance and time required for using the structured diagnostic methods by three specialists in two hospitals. As per the results of the professional survey, five questionnaires and one basic diagnostic method were selected. An SOP was constructed based on the survey results, and a feasibility study showed that the SOP compliance score (out of 5) was 3.45 among the subjects, and 3.25 among the practitioners. The SOP was acceptable and was not deemed difficult to execute. The total execution time was 136.5 minutes, out of which the gastric emptying test time was 129 minutes. This feasibility study of the SOP with structured diagnostic methods for FD confirmed it was adequate for use in KM clinics. It is expected that these study findings will be helpful to clinicians who wish to conduct observational studies as well as to generate quantitative medical records to facilitate Big Data research.

  9. [Evaluation (assessment) of three tests for diagnosis of geohelmints in Colombia].

    PubMed

    López, Myriam Consuelo; Moncada, Ligia Inés; Ariza-Araújo, Yoseth; Fernández-Niño, Julián Alfredo; Reyes, Patricia; Nicholls, Rubén Santiago

    2013-01-01

    Soil-transmitted helminth infections are considered a public health problem in developing countries. The diagnostic tests, both for individual parient diagnosis as for population studies should be evaluated in terms of validity and reliability. To compare the direct examination, the modified Ritchie-Frick method, a Kato-Katz designed by a Brazilian group and one designed by the WHO, for the diagnosis of soil-transmitted helminthes. A diagnostic test reliability study was performed. The same stool sample was analyzed by the same observer using four diagnostic tests. 204 samples were obtained, 194 of those fulfilled the inclusion criteria and were analyzed. The observers did not know the participants' identity neither the other tests results. For the analysis the Kato-Katz (WHO) was considered as the gold standard. For the reliability assessment percent agreement, positive percent agreement, Kappa statistic, and intraclass correlation were performed. The Brazilian Kato-Katz showed a good performance with high sensitivity and specificity for T. trichiura and Hookworm with values of 0.97 and 0.96 respectively, and a high specificity with mild sensitivity for A. lumbricoides (0.95 and 0.79) meanwhile the direct examination and the Ritche-Frick method showed a performance between mild and poor. The differences were higher for hookworm and Trichiuris trichiura than for Ascaris lumbricoides. The Brazilian Kato Katz test could be implemented, but further studies are needed to correlate its operative capacity with its feasibility, availability and cost.

  10. Evidence-based Diagnostics: Adult Septic Arthritis

    PubMed Central

    Carpenter, Christopher R.; Schuur, Jeremiah D.; Everett, Worth W.; Pines, Jesse M.

    2011-01-01

    Background Acutely swollen or painful joints are common complaints in the emergency department (ED). Septic arthritis in adults is a challenging diagnosis, but prompt differentiation of a bacterial etiology is crucial to minimize morbidity and mortality. Objectives The objective was to perform a systematic review describing the diagnostic characteristics of history, physical examination, and bedside laboratory tests for nongonococcal septic arthritis. A secondary objective was to quantify test and treatment thresholds using derived estimates of sensitivity and specificity, as well as best-evidence diagnostic and treatment risks and anticipated benefits from appropriate therapy. Methods Two electronic search engines (PUBMED and EMBASE) were used in conjunction with a selected bibliography and scientific abstract hand search. Inclusion criteria included adult trials of patients presenting with monoarticular complaints if they reported sufficient detail to reconstruct partial or complete 2 × 2 contingency tables for experimental diagnostic test characteristics using an acceptable criterion standard. Evidence was rated by two investigators using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS). When more than one similarly designed trial existed for a diagnostic test, meta-analysis was conducted using a random effects model. Interval likelihood ratios (LRs) were computed when possible. To illustrate one method to quantify theoretical points in the probability of disease whereby clinicians might cease testing altogether and either withhold treatment (test threshold) or initiate definitive therapy in lieu of further diagnostics (treatment threshold), an interactive spreadsheet was designed and sample calculations were provided based on research estimates of diagnostic accuracy, diagnostic risk, and therapeutic risk/benefits. Results The prevalence of nongonococcal septic arthritis in ED patients with a single acutely painful joint is approximately 27% (95% confidence interval [CI] = 17% to 38%). With the exception of joint surgery (positive likelihood ratio [+LR] = 6.9) or skin infection overlying a prosthetic joint (+LR = 15.0), history, physical examination, and serum tests do not significantly alter posttest probability. Serum inflammatory markers such as white blood cell (WBC) counts, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) are not useful acutely. The interval LR for synovial white blood cell (sWBC) counts of 0 × 109–25 × 109/ L was 0.33; for 25 × 109–50 × 109/L, 1.06; for 50 × 109–100 × 109/L, 3.59; and exceeding 100 × 109/L, infinity. Synovial lactate may be useful to rule in or rule out the diagnosis of septic arthritis with a +LR ranging from 2.4 to infinity, and negative likelihood ratio (−LR) ranging from 0 to 0.46. Rapid polymerase chain reaction (PCR) of synovial fluid may identify the causative organism within 3 hours. Based on 56% sensitivity and 90% specificity for sWBC counts of >50 × 109/L in conjunction with best-evidence estimates for diagnosis-related risk and treatment-related risk/benefit, the arthrocentesis test threshold is 5%, with a treatment threshold of 39%. Conclusions Recent joint surgery or cellulitis overlying a prosthetic hip or knee were the only findings on history or physical examination that significantly alter the probability of nongonococcal septic arthritis. Extreme values of sWBC (>50 × 109/L) can increase, but not decrease, the probability of septic arthritis. Future ED-based diagnostic trials are needed to evaluate the role of clinical gestalt and the efficacy of nontraditional synovial markers such as lactate. PMID:21843213

  11. Clinical Outcomes and Cost Effectiveness of Accelerated Diagnostic Protocol in a Chest Pain Center Compared with Routine Care of Patients with Chest Pain

    PubMed Central

    Asher, Elad; Reuveni, Haim; Shlomo, Nir; Gerber, Yariv; Beigel, Roy; Narodetski, Michael; Eldar, Michael; Or, Jacob; Hod, Hanoch; Shamiss, Arie; Matetzky, Shlomi

    2015-01-01

    Aims The aim of this study was to compare in patients presenting with acute chest pain the clinical outcomes and cost-effectiveness of an accelerated diagnostic protocol utilizing contemporary technology in a chest pain unit versus routine care in an internal medicine department. Methods and Results Hospital and 90-day course were prospectively studied in 585 consecutive low-moderate risk acute chest pain patients, of whom 304 were investigated in a designated chest pain center using a pre-specified accelerated diagnostic protocol, while 281 underwent routine care in an internal medicine ward. Hospitalization was longer in the routine care compared with the accelerated diagnostic protocol group (p<0.001). During hospitalization, 298 accelerated diagnostic protocol patients (98%) vs. 57 (20%) routine care patients underwent non-invasive testing, (p<0.001). Throughout the 90-day follow-up, diagnostic imaging testing was performed in 125 (44%) and 26 (9%) patients in the routine care and accelerated diagnostic protocol patients, respectively (p<0.001). Ultimately, most patients in both groups had non-invasive imaging testing. Accelerated diagnostic protocol patients compared with those receiving routine care was associated with a lower incidence of readmissions for chest pain [8 (3%) vs. 24 (9%), p<0.01], and acute coronary syndromes [1 (0.3%) vs. 9 (3.2%), p<0.01], during the follow-up period. The accelerated diagnostic protocol remained a predictor of lower acute coronary syndromes and readmissions after propensity score analysis [OR = 0.28 (CI 95% 0.14–0.59)]. Cost per patient was similar in both groups [($2510 vs. $2703 for the accelerated diagnostic protocol and routine care group, respectively, (p = 0.9)]. Conclusion An accelerated diagnostic protocol is clinically superior and as cost effective as routine in acute chest pain patients, and may save time and resources. PMID:25622029

  12. 77 FR 41188 - Clinical Laboratory Improvement Advisory Committee (CLIAC)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-12

    ... technological advances, such as new test methods and the electronic transmission of laboratory information... potential need for educational materials and resources for sites that test under a Provider-performed Microscopy Certificate; and the increased use of culture-independent microbiology diagnostics and the impact...

  13. Methodology for vocational psychodiagnostics of senior schoolchildren using information technologies

    NASA Astrophysics Data System (ADS)

    Bogdanovskaya, I. M.; Kosheleva, A. N.; Kiselev, P. B.; Davydova, Yu. A.

    2017-01-01

    The article identifies the role and main problems of vocational psychodiagnostics in modern socio-cultural conditions. It analyzes the potentials of information technologies in vocational psychodiagnostics of senior schoolchildren. The article describes the theoretical and methodological grounds, content and diagnostic potentials of the computerized method in vocational psychodiagnostics. The computerized method includes three blocks of sub-tests to identify intellectual potential, personal qualities, professional interests and values, career orientations, as well as subtests to analyze the specific life experience of senior schoolchildren. The results of diagnostics allow developing an integrated psychodiagnostic conclusion with recommendations. The article contains options of software architecture for the given method.

  14. Detecting gear tooth fracture in a high contact ratio face gear mesh

    NASA Technical Reports Server (NTRS)

    Zakrajsek, James J.; Handschuh, Robert F.; Lewicki, David G.; Decker, Harry J.

    1995-01-01

    This paper summarized the results of a study in which three different vibration diagnostic methods were used to detect gear tooth fracture in a high contact ratio face gear mesh. The NASA spiral bevel gear fatigue test rig was used to produce unseeded fault, natural failures of four face gear specimens. During the fatigue tests, which were run to determine load capacity and primary failure mechanisms for face gears, vibration signals were monitored and recorded for gear diagnostic purposes. Gear tooth bending fatigue and surface pitting were the primary failure modes found in the tests. The damage ranged from partial tooth fracture on a single tooth in one test to heavy wear, severe pitting, and complete tooth fracture of several teeth on another test. Three gear fault detection techniques, FM4, NA4*, and NB4, were applied to the experimental data. These methods use the signal average in both the time and frequency domain. Method NA4* was able to conclusively detect the gear tooth fractures in three out of the four fatigue tests, along with gear tooth surface pitting and heavy wear. For multiple tooth fractures, all of the methods gave a clear indication of the damage. It was also found that due to the high contact ratio of the face gear mesh, single tooth fractures did not significantly affect the vibration signal, making this type of failure difficult to detect.

  15. Molecular methods for pathogen and microbial community detection and characterization: current and potential application in diagnostic microbiology.

    PubMed

    Sibley, Christopher D; Peirano, Gisele; Church, Deirdre L

    2012-04-01

    Clinical microbiology laboratories worldwide have historically relied on phenotypic methods (i.e., culture and biochemical tests) for detection, identification and characterization of virulence traits (e.g., antibiotic resistance genes, toxins) of human pathogens. However, limitations to implementation of molecular methods for human infectious diseases testing are being rapidly overcome allowing for the clinical evaluation and implementation of diverse technologies with expanding diagnostic capabilities. The advantages and limitation of molecular techniques including real-time polymerase chain reaction, partial or whole genome sequencing, molecular typing, microarrays, broad-range PCR and multiplexing will be discussed. Finally, terminal restriction fragment length polymorphism (T-RFLP) and deep sequencing are introduced as technologies at the clinical interface with the potential to dramatically enhance our ability to diagnose infectious diseases and better define the epidemiology and microbial ecology of a wide range of complex infections. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. The after breakfast 50-g, 1-hour glucose challenge test in urban Mexican pregnant women: its sensitivity and specificity evaluated by three diagnostic criteria for gestational diabetes mellitus.

    PubMed

    Espinosa de los Monteros, A; Parra, A; Hidalgo, R; Zambrana, M

    1999-04-01

    To study the sensitivity and specificity of the 50-g, 1-hour gestational glucose challenge test performed 1 to 2 hours after a non-standardized home breakfast in urban Mexican women by using three different gestational diabetes mellitus diagnostic criteria. Four hundred and forty-five consecutive women of 24-28 weeks gestation were studied. The glucose challenge test was performed in the fed state and a week later a fasting 100-g, 3-hours oral glucose tolerance test was carried out in all of them. Duplicate serum glucose concentrations were determined by a glucose-oxidase method. Sensitivity and specificity were calculated using three different diagnostic criteria for gestational diabetes mellitus. The glucose challenge test performed as indicated, with a cutoff of 7.8 mmol/L, had 88-89% sensitivity and 85-87% specificity when using as diagnostic criteria those proposed by the National Diabetes Data Group and by Carpenter & Coustan; by using Sacks et al. criteria, the values were 82% and 88%, respectively. Considering only pregnant women > or = 25 years of age, the sensitivity increased to 92% with the National Diabetes Data Group criteria. Pregnant women < 25 years of age had significantly lower blood glucose values than those with age > or = 25 years during the glucose tolerance test. For the general group the sensitivity of the glucose challenge test performed 1 to 2 hours after breakfast was similar, based on the National Diabetes Data Group and the Carpenter & Coustan's diagnostic criteria for gestational diabetes mellitus. However, when pregnant women > or = 25 years of age were considered, the use of the former criteria yielded a slightly better sensitivity.

  17. Potential Biases Introduced by Conflating Screening and Diagnostic Testing in Colorectal Cancer Screening Surveillance

    PubMed Central

    Becker, Elizabeth A.; Griffith, Derek M.; West, Brady T.; Janz, Nancy K.; Resnicow, Ken; Morris, Arden M.

    2015-01-01

    Background Screening and post-symptomatic diagnostic testing are often conflated in cancer screening surveillance research. We examined the error in estimated colorectal cancer (CRC) screening prevalence due to the conflation of screening and diagnostic testing. Methods Using data from the 2008 National Health Interview Survey, we compared weighted prevalence estimates of the use of all testing (screening and diagnostic) and screening in at-risk adults, and calculated the overestimation of screening prevalence across socio-demographic groups. Results The population screening prevalence was overestimated by 23.3%, and the level of overestimation varied widely across socio-demographic groups (median 22.6%, mean 24.8%). The highest levels of overestimation were in non-Hispanic White females (27.4%), adults ages 50–54 (32.0%), and those with the highest socioeconomic vulnerability (low educational attainment (31.3%), low poverty ratio (32.5%), no usual source of health care (54.4%) and not insured (51.6%)) (all p-values < 0.001). Conclusions When the impetus for testing was not included, CRC screening prevalence was overestimated, and patterns of overestimation often aligned with social and economic vulnerability. These results are of concern to researchers who utilize survey data from the Behavioral Risk Factor Surveillance System (BRFSS) to assess cancer screening behaviors, as it is currently not designed to distinguish diagnostic testing from screening. Impact Surveillance research in cancer screening that does not consider the impetus for testing risks measurement error of screening prevalence, impeding progress toward improving population health. Ultimately, in order to craft relevant screening benchmarks and interventions, we must look beyond ‘what’ and ‘when’ and include ‘why.’ PMID:26491056

  18. Reduced-cost Chlamydia trachomatis-specific multiplex real-time PCR diagnostic assay evaluated for ocular swabs and use by trachoma research programmes.

    PubMed

    Butcher, Robert; Houghton, Jo; Derrick, Tamsyn; Ramadhani, Athumani; Herrera, Beatriz; Last, Anna R; Massae, Patrick A; Burton, Matthew J; Holland, Martin J; Roberts, Chrissy H

    2017-08-01

    Trachoma, caused by the intracellular bacterium Chlamydia trachomatis (Ct), is the leading infectious cause of preventable blindness. Many commercial platforms are available that provide highly sensitive and specific detection of Ct DNA. However, the majority of these commercial platforms are inaccessible for population-level surveys in resource-limited settings typical to trachoma control programmes. We developed two low-cost quantitative PCR (qPCR) tests for Ct using readily available reagents on standard real-time thermocyclers. Each multiplex qPCR test targets one genomic and one plasmid Ct target in addition to an endogenous positive control for Homo sapiens DNA. The quantitative performance of the qPCR assays in clinical samples was determined by comparison to a previously evaluated droplet digital PCR (ddPCR) test. The diagnostic performance of the qPCR assays were evaluated against a commercial assay (artus C. trachomatis Plus RG PCR, Qiagen) using molecular diagnostics quality control standards and clinical samples. We examined the yield of Ct DNA prepared from five different DNA extraction kits and a cold chain-free dry-sample preservation method using swabs spiked with fixed concentrations of human and Ct DNA. The qPCR assay was highly reproducible (Ct plasmid and genomic targets mean total coefficients of variance 41.5% and 48.3%, respectively). The assay detected 8/8 core specimens upon testing of a quality control panel and performed well in comparison to commercially marketed comparator test (sensitivity and specificity>90%). Optimal extraction and sample preservation methods for research applications were identified. We describe a pipeline from collection to diagnosis providing the most efficient sample preservation and extraction with significant per test cost savings over a commercial qPCR diagnostic assay. The assay and its evaluation should allow control programs wishing to conduct independent research within the context of trachoma control, access to an affordable test with defined performance characteristics. Copyright © 2017. Published by Elsevier B.V.

  19. Standardizing Plasmodium falciparum infection prevalence measured via microscopy versus rapid diagnostic test.

    PubMed

    Mappin, Bonnie; Cameron, Ewan; Dalrymple, Ursula; Weiss, Daniel J; Bisanzio, Donal; Bhatt, Samir; Gething, Peter W

    2015-11-17

    Large-scale mapping of Plasmodium falciparum infection prevalence relies on opportunistic assemblies of infection prevalence data arising from thousands of P. falciparum parasite rate (PfPR) surveys conducted worldwide. Variance in these data is driven by both signal, the true underlying pattern of infection prevalence, and a range of factors contributing to 'noise', including sampling error, differing age ranges of subjects and differing parasite detection methods. Whilst the former two noise components have been addressed in previous studies, the effect of different diagnostic methods used to determine PfPR in different studies has not. In particular, the majority of PfPR data are based on positivity rates determined by either microscopy or rapid diagnostic test (RDT), yet these approaches are not equivalent; therefore a method is needed for standardizing RDT and microscopy-based prevalence estimates prior to use in mapping. Twenty-five recent Demographic and Health surveys (DHS) datasets from sub-Saharan Africa provide child diagnostic test results derived using both RDT and microscopy for each individual. These prevalence estimates were aggregated across level one administrative zones and a Bayesian probit regression model fit to the microscopy- versus RDT-derived prevalence relationship. An errors-in-variables approach was employed to account for sampling error in both the dependent and independent variables. In addition to the diagnostic outcome, RDT type, fever status and recent anti-malarial treatment were extracted from the datasets in order to analyse their effect on observed malaria prevalence. A strong non-linear relationship between the microscopy and RDT-derived prevalence was found. The results of regressions stratified by the additional diagnostic variables (RDT type, fever status and recent anti-malarial treatment) indicate that there is a distinct and consistent difference in the relationship when the data are stratified by febrile status and RDT brand. The relationships defined in this research can be applied to RDT-derived PfPR data to effectively convert them to an estimate of the parasite prevalence expected using microscopy (or vice versa), thereby standardizing the dataset and improving the signal-to-noise ratio. Additionally, the results provide insight on the importance of RDT brands, febrile status and recent anti-malarial treatment for explaining inconsistencies between observed prevalence derived from different diagnostics.

  20. Use of a primary care database to determine trends in genital chlamydia testing, diagnostic episodes and management in UK general practice, 1990–2004

    PubMed Central

    Hughes, Gwenda; Williams, Tim; Simms, Ian; Mercer, Catherine; Fenton, Kevin; Cassell, Jackie

    2007-01-01

    Objective To determine the extent of testing, diagnostic episodes and management of genital Chlamydia trachomatis (CT) infection in UK primary care using a large primary care database. Methods The incidence of CT tests, diagnostic episodes, treatments and referrals was measured for all adult patients in the General Practice Research Database between 1990 and 2004. Results Rates of CT testing in those aged 12–64 years in 2004 increased to 1439/100 000 patient years (py) in women but only 74/100 000 py in men. Testing rates were highest among 20–24‐year‐old women (5.5% tested in 2004), followed by 25–34‐year‐old women (3.7% tested in 2004). 0.5% of registered 16–24‐year‐old women were diagnosed as having CT infection in 2004. Three‐quarters of patients with a recorded diagnosis of CT had had an appropriate prescription issued in 2004, a proportion that increased from 1990 along with a decrease in referrals to genitourinary medicine. In 2004, general practitioners treated 25.0% of all recorded diagnoses of CT in women and 5.1% of those in men. Conclusions Testing for and diagnostic episodes of CT in primary care have increased since 1990. Testing continues disproportionately to target women aged >24 years. Extremely low rates of testing in men, together with high positivity, demonstrate a missed opportunity for diagnosis of CT and contact tracing in general practice. PMID:17360731

  1. A modified Elek test for detection of toxigenic corynebacteria in the diagnostic laboratory.

    PubMed

    Engler, K H; Glushkevich, T; Mazurova, I K; George, R C; Efstratiou, A

    1997-02-01

    The detection of toxigenicity among Corynebacterium diphtheriae and Corynebacterium ulcerans strains is the most important test for the microbiological diagnosis of diphtheria. Difficulties with current methods, in particular the Elek test, are well documented. We therefore describe a modified Elek test which provides an accurate result after only 16 h of incubation, in contrast to 48 h for the conventional test.

  2. Development and Testing of an LED-Based Near-Infrared Sensor for Human Kidney Tumor Diagnostics

    PubMed Central

    Zabarylo, Urszula; Kirsanov, Dmitry; Belikova, Valeria; Ageev, Vladimir; Usenov, Iskander; Galyanin, Vladislav; Minet, Olaf; Sakharova, Tatiana; Danielyan, Georgy; Feliksberger, Elena; Artyushenko, Viacheslav

    2017-01-01

    Optical spectroscopy is increasingly used for cancer diagnostics. Tumor detection feasibility in human kidney samples using mid- and near-infrared (NIR) spectroscopy, fluorescence spectroscopy, and Raman spectroscopy has been reported (Artyushenko et al., Spectral fiber sensors for cancer diagnostics in vitro. In Proceedings of the European Conference on Biomedical Optics, Munich, Germany, 21–25 June 2015). In the present work, a simplification of the NIR spectroscopic analysis for cancer diagnostics was studied. The conventional high-resolution NIR spectroscopic method of kidney tumor diagnostics was replaced by a compact optical sensing device constructively represented by a set of four light-emitting diodes (LEDs) at selected wavelengths and one detecting photodiode. Two sensor prototypes were tested using 14 in vitro clinical samples of 7 different patients. Statistical data evaluation using principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) confirmed the general applicability of the LED-based sensing approach to kidney tumor detection. An additional validation of the results was performed by means of sample permutation. PMID:28825612

  3. Combination of five diagnostic tests to estimate the prevalence of hookworm infection among school-aged children from a rural area of colombia.

    PubMed

    Barreto, Rafael E; Narváez, Javier; Sepúlveda, Natalia A; Velásquez, Fabián C; Díaz, Sandra C; López, Myriam Consuelo; Reyes, Patricia; Moncada, Ligia I

    2017-09-01

    Public health programs for the control of soil-transmitted helminthiases require valid diagnostic tests for surveillance and parasitic control evaluation. However, there is currently no agreement about what test should be used as a gold standard for the diagnosis of hookworm infection. Still, in presence of concurrent data for multiple tests it is possible to use statistical models to estimate measures of test performance and prevalence. The aim of this study was to estimate the diagnostic accuracy of five parallel tests (direct microscopic examination, Kato-Katz, Harada-Mori, modified Ritchie-Frick, and culture in agar plate) to detect hookworm infections in a sample of school-aged children from a rural area in Colombia. We used both, a frequentist approach, and Bayesian latent class models to estimate the sensitivity and specificity of five tests for hookworm detection, and to estimate the prevalence of hookworm infection in absence of a Gold Standard. The Kato-Katz and agar plate methods had an overall agreement of 95% and kappa coefficient of 0.76. Different models estimated a sensitivity between 76% and 92% for the agar plate technique, and 52% to 87% for the Kato-Katz technique. The other tests had lower sensitivity. All tests had specificity between 95% and 98%. The prevalence estimated by the Kato-Katz and Agar plate methods for different subpopulations varied between 10% and 14%, and was consistent with the prevalence estimated from the combination of all tests. The Harada-Mori, Ritchie-Frick and direct examination techniques resulted in lower and disparate prevalence estimates. Bayesian approaches assuming imperfect specificity resulted in lower prevalence estimates than the frequentist approach. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... in the 80000 series of the Current Procedural Terminology published by the American Medical... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  5. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  6. Selection and Reporting of Statistical Methods to Assess Reliability of a Diagnostic Test: Conformity to Recommended Methods in a Peer-Reviewed Journal

    PubMed Central

    Park, Ji Eun; Han, Kyunghwa; Sung, Yu Sub; Chung, Mi Sun; Koo, Hyun Jung; Yoon, Hee Mang; Choi, Young Jun; Lee, Seung Soo; Kim, Kyung Won; Shin, Youngbin; An, Suah; Cho, Hyo-Min

    2017-01-01

    Objective To evaluate the frequency and adequacy of statistical analyses in a general radiology journal when reporting a reliability analysis for a diagnostic test. Materials and Methods Sixty-three studies of diagnostic test accuracy (DTA) and 36 studies reporting reliability analyses published in the Korean Journal of Radiology between 2012 and 2016 were analyzed. Studies were judged using the methodological guidelines of the Radiological Society of North America-Quantitative Imaging Biomarkers Alliance (RSNA-QIBA), and COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) initiative. DTA studies were evaluated by nine editorial board members of the journal. Reliability studies were evaluated by study reviewers experienced with reliability analysis. Results Thirty-one (49.2%) of the 63 DTA studies did not include a reliability analysis when deemed necessary. Among the 36 reliability studies, proper statistical methods were used in all (5/5) studies dealing with dichotomous/nominal data, 46.7% (7/15) of studies dealing with ordinal data, and 95.2% (20/21) of studies dealing with continuous data. Statistical methods were described in sufficient detail regarding weighted kappa in 28.6% (2/7) of studies and regarding the model and assumptions of intraclass correlation coefficient in 35.3% (6/17) and 29.4% (5/17) of studies, respectively. Reliability parameters were used as if they were agreement parameters in 23.1% (3/13) of studies. Reproducibility and repeatability were used incorrectly in 20% (3/15) of studies. Conclusion Greater attention to the importance of reporting reliability, thorough description of the related statistical methods, efforts not to neglect agreement parameters, and better use of relevant terminology is necessary. PMID:29089821

  7. [Development of a diagnostic test system for early non-invasive detection of prostate cancer based on PCA3 mRNA levels in urine sediment using quantitative reverse tanscription polymerase chain reaction (qRT-PCR)].

    PubMed

    Pavlov, K A; Shkoporov, A N; Khokhlova, E V; Korchagina, A A; Sidorenkov, A V; Grigor'ev, M É; Pushkar', D Iu; Chekhonin, V P

    2013-01-01

    The wide introduction of prostatic specific antigen (PSA) determination into clinical practice has resulted in a larger number of prostate biopsies, while the lower age threshold for PSA has led to a larger number of unnecessary prostate biopsies. Hence, there is a need for new biomarkers that can detect prostate cancer. PCA3 is a noncoding messenger ribonucleic acid (mRNA) that is expressed exclusively in prostate cells. The aim of the study has been to develop a diagnostic test system for early non-invasive detection of prostate cancer based on PCA3 mRNA levels in urine sediment using quantitative reverse transcription polymerase chain reaction (qRT-PCR). As part of the study, a laboratory diagnostic test system prototype has been designed, an application methodology has been developed and specificity and sensitivity data of the method has been assessed. The diagnostic system has demonstrated its ability to detect significantly elevated levels of PCA 3/KLK 3 in samples from prostate cancer (PCa) patients compared with those from healthy men. The findings have shown relatively high diagnostic sensitivity, specificity and negative-predictive values for an early non-invasive screening of prostate cancer

  8. The Health Technology Assessment of companion diagnostics: experience of NICE.

    PubMed

    Byron, Sarah K; Crabb, Nick; George, Elisabeth; Marlow, Mirella; Newland, Adrian

    2014-03-15

    Companion diagnostics are used to aid clinical decision making to identify patients who are most likely to respond to treatment. They are becoming increasingly important as more new pharmaceuticals receive licensed indications that require the use of a companion diagnostic to identify the appropriate patient subgroup for treatment. These pharmaceuticals have proven benefit in the treatment of some cancers and other diseases, and also have potential to precisely tailor treatments to the individual in the future. However, the increasing use of companion diagnostics could place a substantial burden on health system resources to provide potentially high volumes of testing. This situation, in part, has led policy makers and Health Technology Assessment (HTA) bodies to review the policies and methods used to make reimbursement decisions for pharmaceuticals requiring companion diagnostics. The assessment of a pharmaceutical alongside the companion diagnostic used in the clinical trials may be relatively straightforward, although there are a number of challenges associated with assessing pharmaceuticals where a range of alternative companion diagnostics are available for use in routine clinical practice. The UK HTA body, the National Institute for Health and Care Excellence (NICE), has developed policy for considering companion diagnostics using its Technology Appraisal and Diagnostics Assessment Programs. Some HTA bodies in other countries have also adapted their policies and methods to accommodate the assessment of companion diagnostics. Here, we provide insight into the HTA of companion diagnostics for reimbursement decisions and how the associated challenges are being addressed, in particular by NICE. See all articles in this CCR Focus section, "The Precision Medicine Conundrum: Approaches to Companion Diagnostic Co-development." ©2014 AACR.

  9. [Possibilities of the TruScreen for screening of precancer and cancer of the uterine cervix].

    PubMed

    Zlatkov, V

    2009-01-01

    The classic approach of detection of pre-cancer and cancer of uterine cervix includes cytological examination, followed by colposcopy assessment of the detected cytological abnormalities. Real-time devices use in-vivo techniques for the measurement, computerized analysis and classifying of different types of cervical tissues. The aim of the present review is to present the technical characteristics and to discus the diagnostic possibilities of TruScreen-automated optical-electron system for cervical screening. The analysis of the presented in the literature diagnostic value of the method at different grades intraepithelial lesions shows that it has higher sensitivity (67-70%) and lower specificity (81%) in comparison to the Pap test with the following results (45-69% sensitivity and 95% specificity). This makes the method suitable for independent primary screening, as well as for adding the diagnostic assurance of the cytological method.

  10. Rapid polymerase chain reaction diagnosis of white-nose syndrome in bats

    USGS Publications Warehouse

    Lorch, J.M.; Gargas, A.; Meteyer, C.U.; Berlowski-Zier, B. M.; Green, D.E.; Shearn-Bochsler, V.; Thomas, N.J.; Blehert, D.S.

    2010-01-01

    A newly developed polymerase chain reaction (PCR)-based method to rapidly and specifically detect Geomyces destructans on the wings of infected bats from small quantities (1-2 mg) of tissue is described in the current study (methods for culturing and isolating G. destructans from bat skin are also described). The lower limits of detection for PCR were 5 fg of purified fungal DNA or 100 conidia per 2 mg of wing tissue. By using histology as the standard, the PCR had a diagnostic specificity of 100% and a diagnostic sensitivity of 96%, whereas the diagnostic sensitivity of culture techniques was only 54%. The accuracy and fast turnaround time of PCR provides field biologists with valuable information on infection status more rapidly than traditional methods, and the small amount of tissue required for the test would allow diagnosis of white-nose syndrome in live animals.

  11. Automated measurement of carbohydrate-deficient transferrin using the Bio-Rad %CDT by the HPLC test on a Variant HPLC system: evaluation and comparison with other routine procedures.

    PubMed

    Schellenberg, François; Mennetrey, Louise; Girre, Catherine; Nalpas, Bertrand; Pagès, Jean Christophe

    2008-01-01

    In this study, we evaluated the new %CDT by the HPLC method (Bio-Rad, Germany) on a Varianttrade mark HPLC system (Bio-Rad), checked the correlation with well-known methods and calculated the diagnostic value of the test. Intra-run and day-to-day precision values were calculated for samples with extreme serum transferrin concentrations, high trisialotransferrin and interfering conditions (haemolysed, lactescent and icteric samples). The method was compared with two routine procedures, the %CDT TIA (Bio-Rad, Hercules, CA, USA) and the Capillarystrade mark CDT (Sebia, France). A total of 350 clinical sera samples were used for a case-control study. Precision values were better in high CDT and medium CDT pools than in low CDT pools. The serum transferrin concentration had no effect on CDT measurement, except in samples with serum transferrin <1 g/L. Haemolysis was the only interfering situation. The method showed high correlation (r(2) > 0.95) with the two other methods (%CDT TIA and CZE %CDT). The global predictive value of the test was >0.90 at 1.9% cut-off. These results demonstrate that the %CDT by the HPLC test is suitable for CDT routine measurement; the results from the high-throughput Varianttrade mark system are well correlated with other methods and are of high diagnostic value.

  12. Clinical application of high throughput molecular screening techniques for pharmacogenomics

    PubMed Central

    Wiita, Arun P; Schrijver, Iris

    2011-01-01

    Genetic analysis is one of the fastest-growing areas of clinical diagnostics. Fortunately, as our knowledge of clinically relevant genetic variants rapidly expands, so does our ability to detect these variants in patient samples. Increasing demand for genetic information may necessitate the use of high throughput diagnostic methods as part of clinically validated testing. Here we provide a general overview of our current and near-future abilities to perform large-scale genetic testing in the clinical laboratory. First we review in detail molecular methods used for high throughput mutation detection, including techniques able to monitor thousands of genetic variants for a single patient or to genotype a single genetic variant for thousands of patients simultaneously. These methods are analyzed in the context of pharmacogenomic testing in the clinical laboratories, with a focus on tests that are currently validated as well as those that hold strong promise for widespread clinical application in the near future. We further discuss the unique economic and clinical challenges posed by pharmacogenomic markers. Our ability to detect genetic variants frequently outstrips our ability to accurately interpret them in a clinical context, carrying implications both for test development and introduction into patient management algorithms. These complexities must be taken into account prior to the introduction of any pharmacogenomic biomarker into routine clinical testing. PMID:23226057

  13. Diagnosing periprosthetic joint infection: has the era of the biomarker arrived?

    PubMed

    Deirmengian, Carl; Kardos, Keith; Kilmartin, Patrick; Cameron, Alexander; Schiller, Kevin; Parvizi, Javad

    2014-11-01

    The diagnosis of periprosthetic joint infection (PJI) remains a serious clinical challenge. There is a pressing need for improved diagnostic testing methods; biomarkers offer one potentially promising approach. We evaluated the diagnostic characteristics of 16 promising synovial fluid biomarkers for the diagnosis of PJI. Synovial fluid was collected from 95 patients meeting the inclusion criteria of this prospective diagnostic study. All patients were being evaluated for a revision hip or knee arthroplasty, including patients with systemic inflammatory disease and those already receiving antibiotic treatment. The Musculoskeletal Infection Society (MSIS) definition was used to classify 29 PJIs and 66 aseptic joints. Synovial fluid samples were tested by immunoassay for 16 biomarkers optimized for use in synovial fluid. Sensitivity, specificity, and receiver operating characteristic curve analysis were performed to assess for diagnostic performance. Five biomarkers, including human α-defensin 1-3, neutrophil elastase 2, bactericidal/permeability-increasing protein, neutrophil gelatinase-associated lipocalin, and lactoferrin, correctly predicted the MSIS classification of all patients in this study, with 100% sensitivity and specificity for the diagnosis of PJI. An additional eight biomarkers demonstrated excellent diagnostic strength, with an area under the curve of greater than 0.9. Synovial fluid biomarkers exhibit a high accuracy in diagnosing PJI, even when including patients with systemic inflammatory disease and those receiving antibiotic treatment. Considering that these biomarkers match the results of the more complex MSIS definition of PJI, we believe that synovial fluid biomarkers can be a valuable addition to the methods utilized for the diagnosis of infection. Level II, diagnostic study. See Instructions for Authors for a complete description of levels of evidence.

  14. Pretest expectations strongly influence interpretation of abnormal laboratory results and further management

    PubMed Central

    2010-01-01

    Background Abnormal results of diagnostic laboratory tests can be difficult to interpret when disease probability is very low. Although most physicians generally do not use Bayesian calculations to interpret abnormal results, their estimates of pretest disease probability and reasons for ordering diagnostic tests may - in a more implicit manner - influence test interpretation and further management. A better understanding of this influence may help to improve test interpretation and management. Therefore, the objective of this study was to examine the influence of physicians' pretest disease probability estimates, and their reasons for ordering diagnostic tests, on test result interpretation, posttest probability estimates and further management. Methods Prospective study among 87 primary care physicians in the Netherlands who each ordered laboratory tests for 25 patients. They recorded their reasons for ordering the tests (to exclude or confirm disease or to reassure patients) and their pretest disease probability estimates. Upon receiving the results they recorded how they interpreted the tests, their posttest probability estimates and further management. Logistic regression was used to analyse whether the pretest probability and the reasons for ordering tests influenced the interpretation, the posttest probability estimates and the decisions on further management. Results The physicians ordered tests for diagnostic purposes for 1253 patients; 742 patients had an abnormal result (64%). Physicians' pretest probability estimates and their reasons for ordering diagnostic tests influenced test interpretation, posttest probability estimates and further management. Abnormal results of tests ordered for reasons of reassurance were significantly more likely to be interpreted as normal (65.8%) compared to tests ordered to confirm a diagnosis or exclude a disease (27.7% and 50.9%, respectively). The odds for abnormal results to be interpreted as normal were much lower when the physician estimated a high pretest disease probability, compared to a low pretest probability estimate (OR = 0.18, 95% CI = 0.07-0.52, p < 0.001). Conclusions Interpretation and management of abnormal test results were strongly influenced by physicians' estimation of pretest disease probability and by the reason for ordering the test. By relating abnormal laboratory results to their pretest expectations, physicians may seek a balance between over- and under-reacting to laboratory test results. PMID:20158908

  15. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test

    PubMed Central

    2011-01-01

    Background About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Methods Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. Results In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. Conclusion In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and can therefore be considered as alternative diagnostic tools in malaria endemic areas. The species of Plasmodium cannot be identified. PMID:21605401

  16. Quantitative detection of PfHRP2 in saliva of malaria patients in the Philippines

    PubMed Central

    2012-01-01

    Background Malaria is a global health priority with a heavy burden of fatality and morbidity. Improvements in field diagnostics are needed to support the agenda for malaria elimination. Saliva has shown significant potential for use in non-invasive diagnostics, but the development of off-the-shelf saliva diagnostic kits requires best practices for sample preparation and quantitative insight on the availability of biomarkers and the dynamics of immunoassay in saliva. This pilot study measured the levels of the PfHRP2 in patient saliva to inform the development of salivary diagnostic tests for malaria. Methods Matched samples of blood and saliva were collected between January and May, 2011 from eight patients at Palawan Baptist Hospital in Roxas, Palawan, Philippines. Parasite density was determined from thick-film blood smears. Concentrations of PfHRP2 in saliva of malaria-positive patients were measured using a custom chemiluminescent ELISA in microtitre plates. Sixteen negative-control patients were enrolled at UCLA. A substantive difference between this protocol and previous related studies was that saliva samples were stabilized with protease inhibitors. Results Of the eight patients with microscopically confirmed P. falciparum malaria, seven tested positive for PfHRP2 in the blood using rapid diagnostic test kits, and all tested positive for PfHRP2 in saliva. All negative-control samples tested negative for salivary PfHRP2. On a binary-decision basis, the ELISA agreed with microscopy with 100 % sensitivity and 100 % specificity. Salivary levels of PfHRP2 ranged from 17 to 1,167 pg/mL in the malaria-positive group. Conclusion Saliva is a promising diagnostic fluid for malaria when protein degradation and matrix effects are mitigated. Systematic quantitation of other malaria biomarkers in saliva would identify those with the best clinical relevance and suitability for off-the-shelf diagnostic kits. PMID:22631858

  17. Development of quantitative radioactive methodologies on paper to determine important lateral-flow immunoassay parameters.

    PubMed

    Mosley, Garrett L; Nguyen, Phuong; Wu, Benjamin M; Kamei, Daniel T

    2016-08-07

    The lateral-flow immunoassay (LFA) is a well-established diagnostic technology that has recently seen significant advancements due in part to the rapidly expanding fields of paper diagnostics and paper-fluidics. As LFA-based diagnostics become more complex, it becomes increasingly important to quantitatively determine important parameters during the design and evaluation process. However, current experimental methods for determining these parameters have certain limitations when applied to LFA systems. In this work, we describe our novel methods of combining paper and radioactive measurements to determine nanoprobe molarity, the number of antibodies per nanoprobe, and the forward and reverse rate constants for nanoprobe binding to immobilized target on the LFA test line. Using a model LFA system that detects for the presence of the protein transferrin (Tf), we demonstrate the application of our methods, which involve quantitative experimentation and mathematical modeling. We also compare the results of our rate constant experiments with traditional experiments to demonstrate how our methods more appropriately capture the influence of the LFA environment on the binding interaction. Our novel experimental approaches can therefore more efficiently guide the research process for LFA design, leading to more rapid advancement of the field of paper-based diagnostics.

  18. Point-of-care testing in the early diagnosis of acute pesticide intoxication: The example of paraquat.

    PubMed

    Wei, Ting-Yen; Yen, Tzung-Hai; Cheng, Chao-Min

    2018-01-01

    Acute pesticide intoxication is a common method of suicide globally. This article reviews current diagnostic methods and makes suggestions for future development. In the case of paraquat intoxication, it is characterized by multi-organ failure, causing substantial mortality and morbidity. Early diagnosis may save the life of a paraquat intoxication patient. Conventional paraquat intoxication diagnostic methods, such as symptom review and urine sodium dithionite assay, are time-consuming and impractical in resource-scarce areas where most intoxication cases occur. Several experimental and clinical studies have shown the potential of portable Surface Enhanced Raman Scattering (SERS), paper-based devices, and machine learning for paraquat intoxication diagnosis. Portable SERS and new SERS substrates maintain the sensitivity of SERS while being less costly and more convenient than conventional SERS. Paper-based devices provide the advantages of price and portability. Machine learning algorithms can be implemented as a mobile phone application and facilitate diagnosis in resource-limited areas. Although these methods have not yet met all features of an ideal diagnostic method, the combination and development of these methods offer much promise.

  19. Antimicrobial Susceptibility Testing, Drug Resistance Mechanisms, and Therapy of Infections with Nontuberculous Mycobacteria

    PubMed Central

    Nash, Kevin A.; Wallace, Richard J.

    2012-01-01

    Summary: Within the past 10 years, treatment and diagnostic guidelines for nontuberculous mycobacteria have been recommended by the American Thoracic Society (ATS) and the Infectious Diseases Society of America (IDSA). Moreover, the Clinical and Laboratory Standards Institute (CLSI) has published and recently (in 2011) updated recommendations including suggested antimicrobial and susceptibility breakpoints. The CLSI has also recommended the broth microdilution method as the gold standard for laboratories performing antimicrobial susceptibility testing of nontuberculous mycobacteria. This article reviews the laboratory, diagnostic, and treatment guidelines together with established and probable drug resistance mechanisms of the nontuberculous mycobacteria. PMID:22763637

  20. The generation of monoclonal antibodies and their use in rapid diagnostic tests

    USDA-ARS?s Scientific Manuscript database

    Antibodies are the most important component of an immunoassay. In these proceedings we outline novel methods used to generate and select monoclonal antibodies that meet performance criteria for use in rapid lateral flow and microfluidic immunoassay tests for the detection of agricultural pathogens ...

  1. The Diagnostic Accuracy of Cytology for the Diagnosis of Hepatobiliary and Pancreatic Cancers.

    PubMed

    Al-Hajeili, Marwan; Alqassas, Maryam; Alomran, Astabraq; Batarfi, Bashaer; Basunaid, Bashaer; Alshail, Reem; Alaydarous, Shahad; Bokhary, Rana; Mosli, Mahmoud

    2018-06-13

    Although cytology testing is considered a valuable method to diagnose tumors that are difficult to access such as hepato-biliary-pancreatic (HBP) malignancies, its diagnostic accuracy remains unclear. We therefore aimed to investigate the diagnostic accuracy of cytology testing for HBP tumors. We performed a retrospective study of all cytology samples that were used to confirm radiologically detected HBP tumors between 2002 and 2016. The cytology techniques used in our center included fine needle aspiration (FNA), brush cytology, and aspiration of bile. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated in comparison to histological confirmation. From a total of 133 medical records, we calculated an overall sensitivity of 76%, specificity of 74%, a negative likelihood ratio of 0.30, and a positive likelihood ratio of 2.9. Cytology was more accurate in diagnosing lesions of the liver (sensitivity 79%, specificity 57%) and biliary tree (sensitivity 100%, specificity 50%) compared to pancreatic (sensitivity 60%, specificity 83%) and gallbladder lesions (sensitivity 50%, specificity 85%). Cytology was more accurate in detecting primary cancers (sensitivity 77%, specificity 73%) when compared to metastatic cancers (sensitivity 73%, specificity 100%). FNA was the most frequently used cytological technique to diagnose HBP lesions (sensitivity 78.8%). Cytological testing is efficient in diagnosing HBP cancers, especially for hepatobiliary tumors. Given its relative simplicity, cost-effectiveness, and paucity of alternative diagnostic methods, cytology should still be considered as a first-line tool for diagnosing HBP malignancies. © 2018 S. Karger AG, Basel.

  2. A standard test case suite for two-dimensional linear transport on the sphere: results from a collection of state-of-the-art schemes

    NASA Astrophysics Data System (ADS)

    Lauritzen, P. H.; Ullrich, P. A.; Jablonowski, C.; Bosler, P. A.; Calhoun, D.; Conley, A. J.; Enomoto, T.; Dong, L.; Dubey, S.; Guba, O.; Hansen, A. B.; Kaas, E.; Kent, J.; Lamarque, J.-F.; Prather, M. J.; Reinert, D.; Shashkin, V. V.; Skamarock, W. C.; Sørensen, B.; Taylor, M. A.; Tolstykh, M. A.

    2013-09-01

    Recently, a standard test case suite for 2-D linear transport on the sphere was proposed to assess important aspects of accuracy in geophysical fluid dynamics with a "minimal" set of idealized model configurations/runs/diagnostics. Here we present results from 19 state-of-the-art transport scheme formulations based on finite-difference/finite-volume methods as well as emerging (in the context of atmospheric/oceanographic sciences) Galerkin methods. Discretization grids range from traditional regular latitude-longitude grids to more isotropic domain discretizations such as icosahedral and cubed-sphere tessellations of the sphere. The schemes are evaluated using a wide range of diagnostics in idealized flow environments. Accuracy is assessed in single- and two-tracer configurations using conventional error norms as well as novel diagnostics designed for climate and climate-chemistry applications. In addition, algorithmic considerations that may be important for computational efficiency are reported on. The latter is inevitably computing platform dependent, The ensemble of results from a wide variety of schemes presented here helps shed light on the ability of the test case suite diagnostics and flow settings to discriminate between algorithms and provide insights into accuracy in the context of global atmospheric/ocean modeling. A library of benchmark results is provided to facilitate scheme intercomparison and model development. Simple software and data-sets are made available to facilitate the process of model evaluation and scheme intercomparison.

  3. A standard test case suite for two-dimensional linear transport on the sphere: results from a collection of state-of-the-art schemes

    NASA Astrophysics Data System (ADS)

    Lauritzen, P. H.; Ullrich, P. A.; Jablonowski, C.; Bosler, P. A.; Calhoun, D.; Conley, A. J.; Enomoto, T.; Dong, L.; Dubey, S.; Guba, O.; Hansen, A. B.; Kaas, E.; Kent, J.; Lamarque, J.-F.; Prather, M. J.; Reinert, D.; Shashkin, V. V.; Skamarock, W. C.; Sørensen, B.; Taylor, M. A.; Tolstykh, M. A.

    2014-01-01

    Recently, a standard test case suite for 2-D linear transport on the sphere was proposed to assess important aspects of accuracy in geophysical fluid dynamics with a "minimal" set of idealized model configurations/runs/diagnostics. Here we present results from 19 state-of-the-art transport scheme formulations based on finite-difference/finite-volume methods as well as emerging (in the context of atmospheric/oceanographic sciences) Galerkin methods. Discretization grids range from traditional regular latitude-longitude grids to more isotropic domain discretizations such as icosahedral and cubed-sphere tessellations of the sphere. The schemes are evaluated using a wide range of diagnostics in idealized flow environments. Accuracy is assessed in single- and two-tracer configurations using conventional error norms as well as novel diagnostics designed for climate and climate-chemistry applications. In addition, algorithmic considerations that may be important for computational efficiency are reported on. The latter is inevitably computing platform dependent. The ensemble of results from a wide variety of schemes presented here helps shed light on the ability of the test case suite diagnostics and flow settings to discriminate between algorithms and provide insights into accuracy in the context of global atmospheric/ocean modeling. A library of benchmark results is provided to facilitate scheme intercomparison and model development. Simple software and data sets are made available to facilitate the process of model evaluation and scheme intercomparison.

  4. How does study quality affect the results of a diagnostic meta-analysis?

    PubMed Central

    Westwood, Marie E; Whiting, Penny F; Kleijnen, Jos

    2005-01-01

    Background The use of systematic literature review to inform evidence based practice in diagnostics is rapidly expanding. Although the primary diagnostic literature is extensive, studies are often of low methodological quality or poorly reported. There has been no rigorously evaluated, evidence based tool to assess the methodological quality of diagnostic studies. The primary objective of this study was to determine the extent to which variations in the quality of primary studies impact the results of a diagnostic meta-analysis and whether this differs with diagnostic test type. A secondary objective was to contribute to the evaluation of QUADAS, an evidence-based tool for the assessment of quality in diagnostic accuracy studies. Methods This study was conducted as part of large systematic review of tests used in the diagnosis and further investigation of urinary tract infection (UTI) in children. All studies included in this review were assessed using QUADAS, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. The impact of individual components of QUADAS on a summary measure of diagnostic accuracy was investigated using regression analysis. The review divided the diagnosis and further investigation of UTI into the following three clinical stages: diagnosis of UTI, localisation of infection, and further investigation of the UTI. Each stage used different types of diagnostic test, which were considered to involve different quality concerns. Results Many of the studies included in our review were poorly reported. The proportion of QUADAS items fulfilled was similar for studies in different sections of the review. However, as might be expected, the individual items fulfilled differed between the three clinical stages. Regression analysis found that different items showed a strong association with test performance for the different tests evaluated. These differences were observed both within and between the three clinical stages assessed by the review. The results of regression analyses were also affected by whether or not a weighting (by sample size) was applied. Our analysis was severely limited by the completeness of reporting and the differences between the index tests evaluated and the reference standards used to confirm diagnoses in the primary studies. Few tests were evaluated by sufficient studies to allow meaningful use of meta-analytic pooling and investigation of heterogeneity. This meant that further analysis to investigate heterogeneity could only be undertaken using a subset of studies, and that the findings are open to various interpretations. Conclusion Further work is needed to investigate the influence of methodological quality on the results of diagnostic meta-analyses. Large data sets of well-reported primary studies are needed to address this question. Without significant improvements in the completeness of reporting of primary studies, progress in this area will be limited. PMID:15943861

  5. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  6. 20 CFR 404.1519m - Diagnostic tests or procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Diagnostic tests or procedures. 404.1519m... Report Content § 404.1519m Diagnostic tests or procedures. We will request the results of any diagnostic... will not order diagnostic tests or procedures that involve significant risk to you, such as myelograms...

  7. 42 CFR 414.508 - Payment for a new clinical diagnostic laboratory test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Payment for a new clinical diagnostic laboratory... SERVICES Payment for New Clinical Diagnostic Laboratory Tests § 414.508 Payment for a new clinical diagnostic laboratory test. For a new clinical diagnostic laboratory test that is assigned a new or...

  8. The time-frequency method of signal analysis in internal combustion engine diagnostics

    NASA Astrophysics Data System (ADS)

    Avramchuk, V. S.; Kazmin, V. P.; Faerman, V. A.; Le, V. T.

    2017-01-01

    The paper presents the results of the study of applicability of time-frequency correlation functions to solving the problems of internal combustion engine fault diagnostics. The proposed methods are theoretically justified and experimentally tested. In particular, the method’s applicability is illustrated by the example of specially generated signals that simulate the vibration of an engine both during the normal operation and in the case of a malfunction in the system supplying fuel to the cylinders. This method was confirmed during an experiment with an automobile internal combustion engine. The study offers the main findings of the simulation and the experiment and highlights certain characteristic features of time-frequency autocorrelation functions that allow one to identify malfunctions in an engine’s cylinder. The possibility in principle of using time-frequency correlation functions in function testing of the internal combustion engine is demonstrated. The paper’s conclusion proposes further research directions including the application of the method to diagnosing automobile gearboxes.

  9. Pre-test probability of obstructive coronary stenosis in patients undergoing coronary CT angiography: Comparative performance of the modified diamond-Forrester algorithm versus methods incorporating cardiovascular risk factors.

    PubMed

    Ferreira, António Miguel; Marques, Hugo; Tralhão, António; Santos, Miguel Borges; Santos, Ana Rita; Cardoso, Gonçalo; Dores, Hélder; Carvalho, Maria Salomé; Madeira, Sérgio; Machado, Francisco Pereira; Cardim, Nuno; de Araújo Gonçalves, Pedro

    2016-11-01

    Current guidelines recommend the use of the Modified Diamond-Forrester (MDF) method to assess the pre-test likelihood of obstructive coronary artery disease (CAD). We aimed to compare the performance of the MDF method with two contemporary algorithms derived from multicenter trials that additionally incorporate cardiovascular risk factors: the calculator-based 'CAD Consortium 2' method, and the integer-based CONFIRM score. We assessed 1069 consecutive patients without known CAD undergoing coronary CT angiography (CCTA) for stable chest pain. Obstructive CAD was defined as the presence of coronary stenosis ≥50% on 64-slice dual-source CT. The three methods were assessed for calibration, discrimination, net reclassification, and changes in proposed downstream testing based upon calculated pre-test likelihoods. The observed prevalence of obstructive CAD was 13.8% (n=147). Overestimations of the likelihood of obstructive CAD were 140.1%, 9.8%, and 18.8%, respectively, for the MDF, CAD Consortium 2 and CONFIRM methods. The CAD Consortium 2 showed greater discriminative power than the MDF method, with a C-statistic of 0.73 vs. 0.70 (p<0.001), while the CONFIRM score did not (C-statistic 0.71, p=0.492). Reclassification of pre-test likelihood using the 'CAD Consortium 2' or CONFIRM scores resulted in a net reclassification improvement of 0.19 and 0.18, respectively, which would change the diagnostic strategy in approximately half of the patients. Newer risk factor-encompassing models allow for a more precise estimation of pre-test probabilities of obstructive CAD than the guideline-recommended MDF method. Adoption of these scores may improve disease prediction and change the diagnostic pathway in a significant proportion of patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. On the Estimation of Disease Prevalence by Latent Class Models for Screening Studies Using Two Screening Tests with Categorical Disease Status Verified in Test Positives Only

    PubMed Central

    Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.

    2010-01-01

    Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614

  11. The market trend analysis and prospects of cancer molecular diagnostics kits.

    PubMed

    Seo, Ju Hwan; Lee, Joon Woo; Cho, Daemyeong

    2018-01-01

    The molecular diagnostics market can be broadly divided into PCR (rt-PCR, d-PCR), NGS(Next Generation Sequencing), Microarray, FISH(Fluorescent in situ-hybridization) and other categories, based on the diagnostic technique. Also, depending on the disease being diagnosed, the market can also be divided into cancer, infectious diseases, HIV/STDs (herpes, syphilis), and women's health issues such as breast cancer, cervical cancer, ovarian cancer, HPV(human papillomavirus), and vaginitis.Chromosome analysis (including Fluorescent In-situ Hybridization) is one type of blood cancer diagnostic method, which involves the direct detection of individual cells with chromosomal translocation, but there have been problems of sensitivity when using this method. PCR targeting individual genes or the RT (reverse transcription)-PCR method offers outstanding sensitivity, but one drawback is the risk of false-positive reaction caused by contamination of samples, etc. Blood cancer molecular diagnostics kits allow us to overcome these shortcomings, and related products have been under development, with a focus on improving detection sensitivity, enabling multiple tests, and reducing the cost and diagnostic time. Blood cancer molecular diagnostics is usually performed based on platforms such as PCR. The global market for blood cancer molecular diagnostics kits is $ 335.9 million as of 2016 and is expected to reach $ 6980 million in 2026 with an average annual growth rate of 32.9%. The market in South Korea is anticipated to grow at an average annual rate of 28.9%, from $ 3.75 million as of 2016 to $ 60.89 million in 2026. The Market for blood cancer molecular diagnostics kits is judged to be higher in growth possibility due to the increase in the number of cancer patients.

  12. An overview of serological tests currently available for laboratory diagnosis of parasitic infections.

    PubMed

    Fox, J C; Jordan, H E; Kocan, K M; George, T J; Mullins, S T; Barnett, C E; Glenn, B L; Cowell, R L

    1986-03-01

    Current methods and commercial test systems for the diagnosis of parasitic infections in both animals and humans are reviewed. Lists of test kits and their manufacturers are provided along with ordering information: the only commercially available test kits are for the diagnosis of toxoplasmosis in humans or animals and dirofilariasis (heartworm) in dogs. A partial list of diagnostic laboratories and the parasite tests they perform is also provided. Complete lists of diagnostic tests that could be obtained in the private sector are not available but would be useful. Two microfluorometric solid-phase assay systems are reviewed, and adaptations to custom assays for several kinds of parasites are briefly described. User problems in performing tests and interpreting results are stressed with emphasis placed on diagnosis of dirofilariasis in dogs. False-positive serology in dogs without heartworms and negative antibody responses in micro-filariae-positive animals are discussed with respect to proper interpretation of results.

  13. Clinical applications of breath testing

    PubMed Central

    Paschke, Kelly M; Mashir, Alquam

    2010-01-01

    Breath testing has the potential to benefit the medical field as a cost-effective, non-invasive diagnostic tool for diseases of the lung and beyond. With growing evidence of clinical worth, standardization of methods, and new sensor and detection technologies the stage is set for breath testing to gain considerable attention and wider application in upcoming years. PMID:21173863

  14. A computational framework for converting textual clinical diagnostic criteria into the quality data model.

    PubMed

    Hong, Na; Li, Dingcheng; Yu, Yue; Xiu, Qiongying; Liu, Hongfang; Jiang, Guoqian

    2016-10-01

    Constructing standard and computable clinical diagnostic criteria is an important but challenging research field in the clinical informatics community. The Quality Data Model (QDM) is emerging as a promising information model for standardizing clinical diagnostic criteria. To develop and evaluate automated methods for converting textual clinical diagnostic criteria in a structured format using QDM. We used a clinical Natural Language Processing (NLP) tool known as cTAKES to detect sentences and annotate events in diagnostic criteria. We developed a rule-based approach for assigning the QDM datatype(s) to an individual criterion, whereas we invoked a machine learning algorithm based on the Conditional Random Fields (CRFs) for annotating attributes belonging to each particular QDM datatype. We manually developed an annotated corpus as the gold standard and used standard measures (precision, recall and f-measure) for the performance evaluation. We harvested 267 individual criteria with the datatypes of Symptom and Laboratory Test from 63 textual diagnostic criteria. We manually annotated attributes and values in 142 individual Laboratory Test criteria. The average performance of our rule-based approach was 0.84 of precision, 0.86 of recall, and 0.85 of f-measure; the performance of CRFs-based classification was 0.95 of precision, 0.88 of recall and 0.91 of f-measure. We also implemented a web-based tool that automatically translates textual Laboratory Test criteria into the QDM XML template format. The results indicated that our approaches leveraging cTAKES and CRFs are effective in facilitating diagnostic criteria annotation and classification. Our NLP-based computational framework is a feasible and useful solution in developing diagnostic criteria representation and computerization. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. The Alpha-Defensin Immunoassay and Leukocyte Esterase Colorimetric Strip Test for the Diagnosis of Periprosthetic Infection

    PubMed Central

    Wyatt, M.C.; Beswick, A.D.; Kunutsor, S.K.; Wilson, M.J.; Whitehouse, M.R.; Blom, A.W.

    2016-01-01

    Background: Synovial biomarkers have recently been adopted as diagnostic tools for periprosthetic joint infection (PJI), but their utility is uncertain. The purpose of this systematic review and meta-analysis was to synthesize the evidence on the accuracy of the alpha-defensin immunoassay and leukocyte esterase colorimetric strip test for the diagnosis of PJI compared with the Musculoskeletal Infection Society diagnostic criteria. Methods: We performed a systematic review to identify diagnostic technique studies evaluating the accuracy of alpha-defensin or leukocyte esterase in the diagnosis of PJI. MEDLINE and Embase on Ovid, ACM, ADS, arXiv, CERN DS (Conseil Européen pour la Recherche Nucléaire Document Server), CrossRef DOI (Digital Object Identifier), DBLP (Digital Bibliography & Library Project), Espacenet, Google Scholar, Gutenberg, HighWire, IEEE Xplore (Institute of Electrical and Electronics Engineers digital library), INSPIRE, JSTOR (Journal Storage), OAlster (Open Archives Initiative Protocol for Metadata Harvesting), Open Content, Pubget, PubMed, and Web of Science were searched for appropriate studies indexed from inception until May 30, 2015, along with unpublished or gray literature. The classification of studies and data extraction were performed independently by 2 reviewers. Data extraction permitted meta-analysis of sensitivity and specificity with construction of receiver operating characteristic curves for each test. Results: We included 11 eligible studies. The pooled diagnostic sensitivity and specificity of alpha-defensin (6 studies) for PJI were 1.00 (95% confidence interval [CI], 0.82 to 1.00) and 0.96 (95% CI, 0.89 to 0.99), respectively. The area under the curve (AUC) for alpha-defensin and PJI was 0.99 (95% CI, 0.98 to 1.00). The pooled diagnostic sensitivity and specificity of leukocyte esterase (5 studies) for PJI were 0.81 (95% CI, 0.49 to 0.95) and 0.97 (95% CI, 0.82 to 0.99), respectively. The AUC for leukocyte esterase and PJI was 0.97 (95% CI, 0.95 to 0.98). There was substantial heterogeneity among studies for both diagnostic tests. Conclusions: The diagnostic accuracy for PJI was high for both tests. Given the limited number of studies and the large cost difference between the tests, more independent research on these tests is warranted. Level of Evidence: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence. PMID:27307359

  16. High-Throughput Direct Fecal PCR Assay for Detection of Mycobacterium avium subsp. paratuberculosis in Sheep and Cattle

    PubMed Central

    Waldron, Anna M.; Galea, Francesca; Whittington, Ann-Michele; Saunders, Vanessa F.; Begg, Douglas J.; de Silva, Kumudika; Purdie, Auriol C.; Whittington, Richard J.

    2014-01-01

    Johne's disease (JD) is a chronic enteric disease caused by Mycobacterium avium subsp. paratuberculosis that affects ruminants. Transmission occurs by the fecal-oral route. A commonly used antemortem diagnostic test for the detection of M. avium subsp. paratuberculosis in feces is liquid culture; however, a major constraint is the 2- to 3-month incubation period needed for this method. Rapid methods for the detection of M. avium subsp. paratuberculosis based on PCR have been reported, but comprehensive validation data are lacking. We describe here a new test, the high-throughput-Johnes (HT-J), to detect M. avium subsp. paratuberculosis in feces. Its diagnostic accuracy was compared with that of liquid radiometric (Bactec) fecal culture using samples from cattle (1,330 samples from 23 herds) and sheep (596 samples from 16 flocks). The multistage protocol involves the recovery of M. avium subsp. paratuberculosis cells from a fecal suspension, cell rupture by bead beating, extraction of DNA using magnetic beads, and IS900 quantitative PCR. The limit of detection of the assay was 0.0005 pg, and the limit of quantification was 0.005 pg M. avium subsp. paratuberculosis genomic DNA. Only M. avium subsp. paratuberculosis was detected from a panel of 51 mycobacterial isolates, including 10 with IS900-like sequences. Of the 549 culture-negative fecal samples from unexposed herds and flocks, 99% were negative in the HT-J test, while 60% of the bovine- and 84% of the ovine-culture-positive samples were positive in the HT-J test. As similar total numbers of samples from M. avium subsp. paratuberculosis-exposed animals were positive in culture and HT-J tests in both species, and as the results of a McNemar's test were not significant, these methods probably have similar sensitivities, but the true diagnostic sensitivities of these tests are unknown. These validation data meet the consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis and the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines (S. A. Bustin et al., Clin. Chem. 55:611–622, 2009, doi:10.1373/clinchem.2008.112797). The HT-J assay has been approved for use in JD control programs in Australia and New Zealand. PMID:24352996

  17. Applications and Methods for Continuous Monitoring of Physiological Chemistry

    DTIC Science & Technology

    2016-02-04

    product and test platform to verify the performance characteristics of the enzymes when used in diagnostic device fabrication. 1.3 Results This...project had three primary objectives: 1. Engineer a cortisol oxidase enzyme suitable for use in diagnostic devices 2. Large scale production and...for both animal and human use , and for direct sale to other entities to manufacture biosensors and other products for human monitoring. The enzymes

  18. Advances in malaria elimination in Botswana: a dramatic shift to parasitological diagnosis, 2008–2014

    PubMed Central

    Edwards, J. K.; Motlaleng, M.; Namboze, J.; Butt, W.; Obopile, M.; Mosweunyane, T.; Manzi, M.; Takarinda, K. C.; Owiti, P.

    2018-01-01

    Background: Malaria elimination requires infection detection using quality assured diagnostics and appropriate treatment regimens. Although Botswana is moving towards malaria elimination, reports of unconfirmed cases may jeopardise this effort. This study aimed to determine the proportion of cases treated for malaria that were confirmed by rapid diagnostic testing (RDT) and/or microscopy. Methods: This was a retrospective descriptive study using routine national data from the integrated disease surveillance and case-based surveillance systems from 2008 to 2014. The data were categorised into clinical and confirmed cases each year. An analysis of the data on cases registered in three districts that reported approximately 70% of all malaria cases was performed, stratified by year, type of reporting health facilities and diagnostic method. Results: During 2008–2014, 50 487 cases of malaria were reported in Botswana, and the proportion of RDT and/or blood microscopy confirmed cases improved from 6% in 2008 to 89% in 2013. The total number of malaria cases decreased by 97% in the same period, then increased by 41% in 2013. Conclusion: This study shows that malaria diagnostic tests dramatically improved malaria diagnosis and consequently reduced the malaria burden in Botswana. The study identified a need to build capacity on microscopy for species identification, parasite quantification and guiding treatment choices. PMID:29713592

  19. Advances in malaria elimination in Botswana: a dramatic shift to parasitological diagnosis, 2008-2014.

    PubMed

    Moakofhi, K; Edwards, J K; Motlaleng, M; Namboze, J; Butt, W; Obopile, M; Mosweunyane, T; Manzi, M; Takarinda, K C; Owiti, P

    2018-04-25

    Background: Malaria elimination requires infection detection using quality assured diagnostics and appropriate treatment regimens. Although Botswana is moving towards malaria elimination, reports of unconfirmed cases may jeopardise this effort. This study aimed to determine the proportion of cases treated for malaria that were confirmed by rapid diagnostic testing (RDT) and/or microscopy. Methods: This was a retrospective descriptive study using routine national data from the integrated disease surveillance and case-based surveillance systems from 2008 to 2014. The data were categorised into clinical and confirmed cases each year. An analysis of the data on cases registered in three districts that reported approximately 70% of all malaria cases was performed, stratified by year, type of reporting health facilities and diagnostic method. Results: During 2008-2014, 50 487 cases of malaria were reported in Botswana, and the proportion of RDT and/or blood microscopy confirmed cases improved from 6% in 2008 to 89% in 2013. The total number of malaria cases decreased by 97% in the same period, then increased by 41% in 2013. Conclusion: This study shows that malaria diagnostic tests dramatically improved malaria diagnosis and consequently reduced the malaria burden in Botswana. The study identified a need to build capacity on microscopy for species identification, parasite quantification and guiding treatment choices.

  20. Predictors and Diagnostic Significance of the Adenosine Related Side Effects on Myocardial Perfusion SPECT/CT Imaging

    PubMed Central

    Yıldırım Poyraz, Nilüfer; Özdemir, Elif; Poyraz, Barış Mustafa; Kandemir, Zuhal; Keskin, Mutlay; Türkölmez, Şeyda

    2014-01-01

    Objective: The aim of this study was to investigate the relationship between patient characteristics and adenosine-related side-effects during stress myocard perfusion imaging (MPI). The effect of presence of adenosine-related side-effects on the diagnostic value of MPI with integrated SPECT/CT system for coronary artery disease (CAD), was also assessed in this study. Methods: Total of 281 patients (109 M, 172 F; mean age:62.6±10) who underwent standard adenosine stress protocol for MPI, were included in this study. All symptoms during adenosine infusion were scored according to the severity and duration. For the estimation of diagnostic value of adenosine MPI with integrated SPECT/CT system, coronary angiography (CAG) or clinical follow-up were used as gold standard. Results: Total of 173 patients (61.6%) experienced adenosine-related side-effects (group 1); flushing, dyspnea, and chest pain were the most common. Other 108 patients completed pharmacologic stress (PS) test without any side-effects (group 2). Test tolerability were similar in the patients with cardiovascular or airway disease to others, however dyspnea were observed significantly more common in patients with mild airway disease. Body mass index (BMI) ≥30 kg/m2 and age ≤45 years were independent predictors of side-effects. The diagnostic value of MPI was similar in both groups. Sensitivity of adenosine MPI SPECT/CT was calculated to be 86%, specificity was 94% and diagnostic accuracy was 92% for diagnosis of CAD. Conclusion: Adenosine MPI is a feasible and well tolerated method in patients who are not suitable for exercise stress test as well as patients with cardiopulmonary disease. However age ≤45 years and BMI ≥30 kg/m2 are the positive predictors of adenosine-related side-effects, the diagnostic value of adenosine MPI SPECT/CT is not affected by the presence of adenosine related side-effects. PMID:25541932

  1. A Diagnostic Model for Dementia in Clinical Practice-Case Methodology Assisting Dementia Diagnosis.

    PubMed

    Londos, Elisabet

    2015-04-02

    Dementia diagnosis is important for many different reasons. Firstly, to separate dementia, or major neurocognitive disorder, from MCI (mild cognitive impairment), mild neurocognitive disorder. Secondly, to define the specific underlying brain disorder to aid treatment, prognosis and decisions regarding care needs and assistance. The diagnostic method of dementias is a puzzle of different data pieces to be fitted together in the best possible way to reach a clinical diagnosis. Using a modified case methodology concept, risk factors affecting cognitive reserve and symptoms constituting the basis of the brain damage hypothesis, can be visualized, balanced and reflected against test results as well as structural and biochemical markers. The model's origin is the case method initially described in Harvard business school, here modified to serve dementia diagnostics.

  2. A Diagnostic Model for Dementia in Clinical Practice—Case Methodology Assisting Dementia Diagnosis

    PubMed Central

    Londos, Elisabet

    2015-01-01

    Dementia diagnosis is important for many different reasons. Firstly, to separate dementia, or major neurocognitive disorder, from MCI (mild cognitive impairment), mild neurocognitive disorder. Secondly, to define the specific underlying brain disorder to aid treatment, prognosis and decisions regarding care needs and assistance. The diagnostic method of dementias is a puzzle of different data pieces to be fitted together in the best possible way to reach a clinical diagnosis. Using a modified case methodology concept, risk factors affecting cognitive reserve and symptoms constituting the basis of the brain damage hypothesis, can be visualized, balanced and reflected against test results as well as structural and biochemical markers. The model’s origin is the case method initially described in Harvard business school, here modified to serve dementia diagnostics. PMID:26854146

  3. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-10-15

    With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.

  4. The Relationship of Comorbidities and Patient Navigation to Time to Diagnostic Resolution after Abnormal Cancer Screening

    PubMed Central

    Whitley, Elizabeth M; Raich, Peter C; Dudley, Donald J; Freund, Karen M; Paskett, Electra D; Patierno, Steven R; Simon, Melissa; Warren-Mears, Victoria; Snyder, Frederick R

    2016-01-01

    Background Whether patient navigation improves outcomes in patients with comorbidities is unknown. Study aims were to determine the effect of comorbidities on time to diagnostic resolution following an abnormal cancer screening test, and to examine for patients with comorbidities, if patient navigation improves timeliness and likelihood of diagnostic resolution compared to patients without navigation. Methods A secondary analysis from the Patient Navigation Research Program sites that collected comorbidity data using the Charlson Comorbidity Index (CCI) was conducted. Participants were 6,349 patients with abnormal breast, cervical, colon or prostate cancer screening tests between 2007 and 2011. The intervention was patient navigation or usual care. CCI data were highly skewed across projects and cancer sites and were categorized as 0, no comorbidities identified, CCI score of 0 (76% of cases); 1, CCI score of 1 (16% of cases); or 2, CCI score of ≥2 (8% of cases). A separate adjusted hazards ratio for each site and cancer type was obtained, and then pooled using meta-analysis random effects methodology. Results Having a CCI score of ≥2 delayed the time to diagnostic resolution following an abnormal cancer screening test compared with those with fewer than one comorbidity. Patient Navigation reduced delays in diagnostic resolution with the greatest benefit seen in those with a CCI score of ≥2. Conclusions Persons with a CCI score of ≥2 experienced significant delays in timely diagnostic care compared to patients without comorbidities. Patient navigation was effective in reducing delays in diagnostic resolution among those with CCI scores > 1. PMID:27648520

  5. Diagnostic Peptide Discovery: Prioritization of Pathogen Diagnostic Markers Using Multiple Features

    PubMed Central

    Carmona, Santiago J.; Sartor, Paula A.; Leguizamón, María S.; Campetella, Oscar E.; Agüero, Fernán

    2012-01-01

    The availability of complete pathogen genomes has renewed interest in the development of diagnostics for infectious diseases. Synthetic peptide microarrays provide a rapid, high-throughput platform for immunological testing of potential B-cell epitopes. However, their current capacity prevent the experimental screening of complete “peptidomes”. Therefore, computational approaches for prediction and/or prioritization of diagnostically relevant peptides are required. In this work we describe a computational method to assess a defined set of molecular properties for each potential diagnostic target in a reference genome. Properties such as sub-cellular localization or expression level were evaluated for the whole protein. At a higher resolution (short peptides), we assessed a set of local properties, such as repetitive motifs, disorder (structured vs natively unstructured regions), trans-membrane spans, genetic polymorphisms (conserved vs. divergent regions), predicted B-cell epitopes, and sequence similarity against human proteins and other potential cross-reacting species (e.g. other pathogens endemic in overlapping geographical locations). A scoring function based on these different features was developed, and used to rank all peptides from a large eukaryotic pathogen proteome. We applied this method to the identification of candidate diagnostic peptides in the protozoan Trypanosoma cruzi, the causative agent of Chagas disease. We measured the performance of the method by analyzing the enrichment of validated antigens in the high-scoring top of the ranking. Based on this measure, our integrative method outperformed alternative prioritizations based on individual properties (such as B-cell epitope predictors alone). Using this method we ranked 10 million 12-mer overlapping peptides derived from the complete T. cruzi proteome. Experimental screening of 190 high-scoring peptides allowed the identification of 37 novel epitopes with diagnostic potential, while none of the low scoring peptides showed significant reactivity. Many of the metrics employed are dependent on standard bioinformatic tools and data, so the method can be easily extended to other pathogen genomes. PMID:23272069

  6. Genetic testing for patients with renal disease: procedures, pitfalls, and ethical considerations.

    PubMed

    Korf, B R

    1999-07-01

    The Human Genome Project is rapidly producing insights into the molecular basis of human genetic disorders. The most immediate clinical benefit is the advent of new diagnostic methods. Molecular diagnostic tools are available for several genetic renal disorders and are in development for many more. Two general approaches to molecular diagnosis are linkage-based testing and direct mutation detection. The former is used when the gene has not been cloned but has been mapped in relation to polymorphic loci. Linkage-based testing is also helpful when a large diversity of mutations makes direct detection difficult. Limitations include the need to study multiple family members, the need for informative polymorphisms, and genetic heterogeneity. Direct mutation detection is limited by genetic heterogeneity and the need to distinguish nonpathogenic allelic variants from pathogenic mutations. Molecular testing raises a number of complex ethical issues, including those associated with prenatal or presymptomatic diagnosis. In addition, there are concerns about informed consent, privacy, genetic discrimination, and technology transfer for newly developed tests. Health professionals need to be aware of the technical and ethical implications of these new methods of testing, as well as the complexities in test interpretation, as molecular approaches are increasingly integrated into medical practice.

  7. The role of modern diagnostic imaging in diagnosing and differentiating kidney diseases in children.

    PubMed

    Maliborski, Artur; Zegadło, Arkadiusz; Placzyńska, Małgorzata; Sopińska, Małgorzata; Lichosik, Marianna; Jobs, Katarzyna

    2018-01-01

    Urinary tract diseases are in the group of the most commonly diagnosed medical conditions in pediatric patients. Many diseases with different etiologies are accompanied by pain, fever, hematuria, or urinary tract dysfunction. Those most common ones in children are urinary tract infections and congenital malformation. They can also represent tumors or changes caused by systemic diseases. Clinical tests and even more often additional imaging studies are required to make a proper diagnosis of urinary tract diseases. Just a few decades ago urography, cystography or voiding cystourethrography were the main methods in diagnostic imaging of the urinary tract. Today's imaging methods supported by digital radiographic and fluoroscopy systems, high sensitivity detectors with quantum detection, advanced algorithms eliminating motion artifacts, modern medical imaging monitors with a resolution of three or even eight megapixels significantly differ from conventional radiographic methods. The methods that are currently usually performed are: computed tomography, magnetic resonance imaging, isotopic methods and ultrasonography using elastography and new solutions in Doppler imaging. Modern techniques are currently focused on reducing radiation exposure with better imaging capabilities. The development of these techniques became an essential diagnostic aid in nephrological and urological practice. The aim of this paper is to present the latest solutions that are currently used in the diagnostic imaging of urinary tract diseases.

  8. First round of external quality assessment of dengue diagnostics in the WHO Western Pacific Region, 2013.

    PubMed

    Pok, Kwoon Yong; Squires, Raynal C; Tan, Li Kiang; Takasaki, Tomohiko; Abubakar, Sazaly; Hasebe, Futoshi; Partridge, Jeffrey; Lee, Chin Kei; Lo, Janice; Aaskov, John; Ng, Lee Ching; Konings, Frank

    2015-01-01

    Accurate laboratory testing is a critical component of dengue surveillance and control. The objective of this programme was to assess dengue diagnostic proficiency among national-level public health laboratories in the World Health Organization (WHO) Western Pacific Region. Nineteen national-level public health laboratories performed routine dengue diagnostic assays on a proficiency testing panel consisting of two modules: one containing commercial serum samples spiked with cultured dengue viruses for the detection of nucleic acid and non-structural protein 1 (NS1) (Module A) and one containing human serum samples for the detection of anti-dengue virus antibodies (Module B). A review of logistics arrangements was also conducted. All 16 laboratories testing Module A performed reverse transcriptase polymerase chain reaction (RT-PCR) for both RNA and serotype detection. Of these, 15 had correct results for RNA detection and all 16 correctly serotyped the viruses. All nine laboratories performing NS1 antigen detection obtained the correct results. Sixteen of the 18 laboratories using IgM assays in Module B obtained the correct results as did the 13 laboratories that performed IgG assays. Detection of ongoing/recent dengue virus infection by both molecular (RT-PCR) and serological methods (IgM) was available in 15/19 participating laboratories. This first round of external quality assessment of dengue diagnostics was successfully conducted in national-level public health laboratories in the WHO Western Pacific Region, revealing good proficiency in both molecular and serological testing. Further comprehensive diagnostic testing for dengue virus and other priority pathogens in the Region will be assessed during future rounds.

  9. A general diagnostic model applied to language testing data.

    PubMed

    von Davier, Matthias

    2008-11-01

    Probabilistic models with one or more latent variables are designed to report on a corresponding number of skills or cognitive attributes. Multidimensional skill profiles offer additional information beyond what a single test score can provide, if the reported skills can be identified and distinguished reliably. Many recent approaches to skill profile models are limited to dichotomous data and have made use of computationally intensive estimation methods such as Markov chain Monte Carlo, since standard maximum likelihood (ML) estimation techniques were deemed infeasible. This paper presents a general diagnostic model (GDM) that can be estimated with standard ML techniques and applies to polytomous response variables as well as to skills with two or more proficiency levels. The paper uses one member of a larger class of diagnostic models, a compensatory diagnostic model for dichotomous and partial credit data. Many well-known models, such as univariate and multivariate versions of the Rasch model and the two-parameter logistic item response theory model, the generalized partial credit model, as well as a variety of skill profile models, are special cases of this GDM. In addition to an introduction to this model, the paper presents a parameter recovery study using simulated data and an application to real data from the field test for TOEFL Internet-based testing.

  10. 30 CFR 250.525 - What do I submit if my casing diagnostic test requires action?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What do I submit if my casing diagnostic test... if my casing diagnostic test requires action? Within 14 days after you perform a casing diagnostic... Corrective Action Plan within 30 days of the diagnostic test. (b) a casing pressure request, Regional...

  11. Diagnostic microbiology in veterinary dermatology: present and future.

    PubMed

    Guardabassi, Luca; Damborg, Peter; Stamm, Ivonne; Kopp, Peter A; Broens, Els M; Toutain, Pierre-Louis

    2017-02-01

    The microbiology laboratory can be perceived as a service provider rather than an integral part of the healthcare team. The aim of this review is to discuss the current challenges of providing a state-of-the-art diagnostic veterinary microbiology service including the identification (ID) and antimicrobial susceptibility testing (AST) of key pathogens in veterinary dermatology. The Study Group for Veterinary Microbiology (ESGVM) of the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) identified scientific, technological, educational and regulatory issues impacting the predictive value of AST and the quality of the service offered by microbiology laboratories. The advent of mass spectrometry has significantly reduced the time required for ID of key pathogens such as Staphylococcus pseudintermedius. However, the turnaround time for validated AST methods has remained unchanged for many years. Beyond scientific and technological constraints, AST methods are not harmonized and clinical breakpoints for some antimicrobial drugs are either missing or inadequate. Small laboratories, including in-clinic laboratories, are usually not adequately equipped to run up-to-date clinical microbiologic diagnostic tests. ESGVM recommends the use of laboratories employing mass spectrometry for ID and broth micro-dilution for AST, and offering assistance by expert microbiologists on pre- and post-analytical issues. Setting general standards for veterinary clinical microbiology, promoting antimicrobial stewardship, and the development of new, validated and rapid diagnostic methods, especially for AST, are among the missions of ESGVM. © 2017 The Authors. Veterinary Dermatology published by John Wiley & Sons Ltd on behalf of the ESVD and ACVD.

  12. State of the art diagnostic of mold diseases: a practical guide for clinicians.

    PubMed

    Beirão, F; Araujo, R

    2013-01-01

    The epidemiology of fungal diseases changed, and molds have been increasingly associated with high mortality in severe immunocompromised patients. Invasive mold diseases may originate from the airborne conidia through inhalation or inoculation in skin fissures associated with indwelling catheters, wounds, burns, or onychomycosis. The diagnosis and treatment of fungal diseases is problematic and raises considerable challenges. Diagnosis of invasive mold diseases includes several methodologies, of which the most commonly used are the cultural methods, antigen testing, nucleic acid detection, and radiological imaging. Galactomannan and (1 → 3)-β-D-glucan detection significantly improved mold diagnosis in the last decade. Several molecular strategies have been proposed over the years but no consensus was achieved for standardized protocols or cut-off values. Recently, the first commercially available molecular assay for detection of Aspergillus was tested and the results were highly reproducible. In addition, blood cultures may also be helpful for invasive aspergillosis by following a novel procedure for the recovery of Aspergillus spp. from blood cultures. The association of distinct diagnostic methods, particularly molecular tests, galactomannan, and/or (1 → 3)-β-D-glucan detection, may provide earlier and more sensitive diagnosis of mold diseases and be indicative for early antifungal treatment. Accurate routine use of diagnostic tests can be cost-effective for laboratories and be of great value to patients.

  13. Clinical Evaluation of a Loop-Mediated Amplification Kit for Diagnosis of Imported Malaria

    PubMed Central

    Polley, Spencer D.; González, Iveth J.; Mohamed, Deqa; Daly, Rosemarie; Bowers, Kathy; Watson, Julie; Mewse, Emma; Armstrong, Margaret; Gray, Christen; Perkins, Mark D.; Bell, David; Kanda, Hidetoshi; Tomita, Norihiro; Kubota, Yutaka; Mori, Yasuyoshi; Chiodini, Peter L.; Sutherland, Colin J.

    2013-01-01

    Background. Diagnosis of malaria relies on parasite detection by microscopy or antigen detection; both fail to detect low-density infections. New tests providing rapid, sensitive diagnosis with minimal need for training would enhance both malaria diagnosis and malaria control activities. We determined the diagnostic accuracy of a new loop-mediated amplification (LAMP) kit in febrile returned travelers. Methods. The kit was evaluated in sequential blood samples from returned travelers sent for pathogen testing to a specialist parasitology laboratory. Microscopy was performed, and then malaria LAMP was performed using Plasmodium genus and Plasmodium falciparum–specific tests in parallel. Nested polymerase chain reaction (PCR) was performed on all samples as the reference standard. Primary outcome measures for diagnostic accuracy were sensitivity and specificity of LAMP results, compared with those of nested PCR. Results. A total of 705 samples were tested in the primary analysis. Sensitivity and specificity were 98.4% and 98.1%, respectively, for the LAMP P. falciparum primers and 97.0% and 99.2%, respectively, for the Plasmodium genus primers. Post hoc repeat PCR analysis of all 15 tests with discrepant results resolved 4 results in favor of LAMP, suggesting that the primary analysis had underestimated diagnostic accuracy. Conclusions. Malaria LAMP had a diagnostic accuracy similar to that of nested PCR, with a greatly reduced time to result, and was superior to expert microscopy. PMID:23633403

  14. Efficacy of a chairside diagnostic test kit for estimation of C-reactive protein levels in periodontal disease

    PubMed Central

    Nagarale, Girish; Ravindra, S.; Thakur, Srinath; Setty, Swati

    2010-01-01

    Background: C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. Aim: The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. Materials and Methods: A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. Results: CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Conclusion: Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis. PMID:21731244

  15. Aquifer test interpretation using derivative analysis and diagnostic plots

    NASA Astrophysics Data System (ADS)

    Hernández-Espriú, Antonio; Real-Rangel, Roberto; Cortés-Salazar, Iván; Castro-Herrera, Israel; Luna-Izazaga, Gabriela; Sánchez-León, Emilio

    2017-04-01

    Pumping tests remain a method of choice to deduce fundamental aquifer properties and to assess well condition. In the oil and gas (O&G) industry, well testing has been the core technique in examining reservoir behavior over the last 50 years. The pressure derivative by Bourdet, it is perhaps, the most significant single development in the history of well test analysis. Recently, the so-called diagnostics plots (e.g. drawdown and drawdown derivative in a log-log plot) have been successfully tested in aquifers. However, this procedure is still underutilized by groundwater professionals. This research illustrates the applicability range, advantages and drawbacks (e.g. smoothing procedures) of diagnostic plots using field examples from a wide spectrum of tests (short/long tests, constant/variable flow rates, drawdown/buildup stages, pumping well/observation well) in dissimilar geological conditions. We analyze new and pre-existent aquifer tests in Mexico, USA, Canada, Germany, France and Saudi Arabia. In constant flow rate tests, our results show that derivative analysis is an easy, robust and powerful tool to assess near-borehole damage effects, formation heterogeneity, boundaries, flow regimes, infinite-acting radial stages, i.e., valid Theisian framework, and fracture-driven flow. In step tests, the effectiveness relies on high-frequency drawdown measurements. Moreover, we adapt O&G analytical solutions to cater for the conditions in groundwater systems. In this context, further parameters can be computed analytically from the plots, such as skin factor, head losses, wellbore storage, distance to the boundary, channel-aquifer and/or fracture zone width, among others. Therefore, diagnostic plots should be considered a mandatory tool for pumping tests analysis among hydrogeologists. This project has been supported by DGAPA (UNAM) under the research project PAPIIT IN-112815.

  16. Five common tumor biomarkers and CEA for diagnosing early gastric cancer: A protocol for a network meta-analysis of diagnostic test accuracy.

    PubMed

    Shen, Minghui; Wang, Hui; Wei, Kongyuan; Zhang, Jianling; You, Chongge

    2018-05-01

    Although surgical resection is the recommended treatment for the patients with gastric cancer, lots of patients show advanced or metastatic gastric cancer at the time of diagnosis. Detection of gastric cancer at early stages is a huge challenge because of lack of appropriate detection tests. Unfortunately, existing clinical guidelines focusing on early diagnosis of gastric cancer do not provide consistent and prudent evidence. Serum carcinoembryonic antigen was considered as a complementary test, although it is not good enough to diagnose early gastric cancer. There are no other tumor markers recommended for diagnosing early gastric cancer. This study aims to evaluate and compare the diagnostic accuracy of 5 common tumor biomarkers (CA19-9, CA125, PG, IncRNA, and DNA methylation) and CEA and their combinations for diagnosing gastric cancer through network meta-analysis method, and to rank these tests using a superiority index. PubMed, EMBASE.com, and the Cochrane Central Register of Controlled Trials (CENTRAL) will be searched from their inception to March 2018. We will include diagnostic tests which assessed the accuracy of the above-mentioned tumor biomarkers and CEA for diagnosing gastric cancer. The risk of bias for each study will be independently assessed as low, moderate, or high using criteria adapted from Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Network meta-analysis will be performed using STATA 12.0 and R 3.4.1 software. The competing diagnostic tests will be ranked by a superiority index. This study is ongoing and will be submitted to a peer-reviewed journal for publication. This study will provide systematically suggestions to select different tumor biomarkers for detecting the early gastric cancer.

  17. Accuracy of the radioactive copper incorporation test in the diagnosis of Wilson disease.

    PubMed

    Członkowska, Anna; Rodo, Maria; Wierzchowska-Ciok, Agata; Smolinski, Lukasz; Litwin, Tomasz

    2018-02-08

    In Wilson disease (WD), copper accumulates in the liver and other tissues because of mutations in the ATP7B copper transporter gene. Early and effective anticopper treatment is crucial. However, routine diagnostic methods based on clinical findings, copper metabolism tests, liver biopsies and DNA analyses do not always provide a conclusive diagnosis. The aim was to evaluate radioactive copper incorporation as a diagnostic test. We included cases with a diagnosis of WD supported by radiocopper testing and later, when available, confirmed by DNA analysis. Incorporation of 64 Cu was measured at 2, 24 and 48 hours following intravenous injection. Diagnostic accuracy (area under the receiver operating characteristic curve [AUC]), sensitivity, specificity and predictive value were assessed for 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios and compared with serum measurements of ceruloplasmin, copper, non-ceruloplasmin-bound copper and urinary 24-hours copper excretion. Patients having two pathogenic ATP7B mutations (homozygotes/compound heterozygotes) (n = 74) had significantly lower 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios than heterozygote controls (n = 21) (mean 0.14 and 0.12 vs 0.49 and 0.63, respectively; both P < .001). Of note, 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios had excellent diagnostic accuracy, with AUCs approaching 1, and only 24-hours urinary copper excretion displayed similar positive features. Other copper metabolism tests studied had lower accuracy, specificity and sensitivity. The radioactive copper test had excellent diagnostic accuracy and may be useful in the evaluation of new therapies aimed at restoring ATP7B function. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Current methods of laboratory diagnosis of Chlamydia trachomatis infections.

    PubMed Central

    Black, C M

    1997-01-01

    Infections caused by Chlamydia trachomatis are probably the most common sexually transmitted diseases in the United States. Commonly unrecognized and often inadequately treated, chlamydial infections can ascend the reproductive tract and cause pelvic inflammatory disease, which often results in the devastating consequences of infertility, ectopic pregnancy, or chronic pelvic pain. C. trachomatis infections are also known to increase the risk for human immunodeficiency virus infection. The obligate intracellular life cycle of C. trachomatis has traditionally required laboratory diagnostic tests that are technically demanding, labor-intensive, expensive, and difficult to access. In spite of these historical challenges, however, laboratory diagnosis of C. trachomatis has been a rapidly advancing area in which there is presently a wide array of commercial diagnostic technologies, costs, manufacturers. This review describes and compares the diagnostic methods for C. trachomatis infection that are currently approved for use in the United States, including the newest DNA amplification technologies which are yet to be licensed for commercial use. Issues to consider in selecting a test for purposes of screening versus diagnosis based on prevalence, performance, legal, social, and cost issues are also discussed. PMID:8993862

  19. Design issues in a randomized controlled trial of a pre-emptive versus empiric antifungal strategy for invasive aspergillosis in patients with high-risk hematologic malignancies.

    PubMed

    Morrissey, C Orla; Chen, Sharon C-A; Sorrell, Tania C; Bradstock, Kenneth F; Szer, Jeffrey; Halliday, Catriona L; Gilroy, Nicole M; Schwarer, Anthony P; Slavin, Monica A

    2011-02-01

    Invasive aspergillosis (IA) is a major cause of mortality in patients with hematological malignancies, due largely to the inability of traditional culture and biopsy methods to make an early or accurate diagnosis. Diagnostic accuracy studies suggest that Aspergillus galactomannan (GM) enzyme immunoassay (ELISA) and Aspergillus PCR-based methods may overcome these limitations, but their impact on patient outcomes should be evaluated in a diagnostic randomized controlled trial (D-RCT). This article describes the methodology of a D-RCT which compares a new pre-emptive strategy (GM-ELISA- and Aspergillus PCR-driven antifungal therapy) with the standard fever-driven empiric antifungal treatment strategy. Issues including primary end-point and patient selection, duration of screening, choice of tests for the pre-emptive strategy, antifungal prophylaxis and bias control, which were considered in the design of the trial, are discussed. We suggest that the template presented herein is considered by researchers when evaluating the utility of new diagnostic tests (ClinicalTrials.gov number, NCT00163722).

  20. Diagnosis of Periodontal Diseases: Building a Bridge from Today's Methods to Tomorrow's Technology.

    ERIC Educational Resources Information Center

    Jeffcoat, Marjorie K.

    1994-01-01

    A discussion of advancements in diagnosis of periodontal diseases looks first at the screening process, reviews specific periodontal diseases and their clinical signs and symptoms, and explains both traditional and newly developed diagnostic tests. A framework for understanding the tests' clinical usefulness is also presented. (MSE)

  1. Reporting Subscores Using R: A Software Review

    ERIC Educational Resources Information Center

    Dai, Shenghai; Svetina, Dubravka; Wang, Xiaolin

    2017-01-01

    There is an increasing interest in reporting test subscores for diagnostic purposes. In this article, we review nine popular R packages (subscore, mirt, TAM, sirt, CDM, NPCD, lavaan, sem, and OpenMX) that are capable of implementing subscore-reporting methods within one or more frameworks including classical test theory, multidimensional item…

  2. Our experience with atopy patch tests with aeroallergens.

    PubMed

    Celakovská, Jarmila; Ettlerová, Kvetuse; Ettler, Karel; Vanecková, Jaroslava

    2013-01-01

    Aim of our study was to evaluate the importance of atopy patch testing with aeroallergens as a diagnostic method in patients suffering from atopic dermatitis. The complet dermatological and allergological examinations were performed in 29 patients; 10 men, 19 women with the average age of 27.8 years, min. 17, max. 57 years; with the median SCORAD 24.2 points, s.d. 13.3 points. Wormwood, grass, dog dander, cat dander, dermatophagoides pharinae, dermatophagoides pteronyssinus and birch pollen were examined in diagnostic procedures. Skin prick tests, specific IgE were examined; the atopy patch tests were performed with aeroallergens for skin prick tests in concentration 1 x skin prick tests. Specific IgE and skin prick tests to one or more tested aeroallergens were positive altogether in 27 patients; atopy patch tests were positive only in one of these patients. For atopy patch testing with aeroallergens the concentration of 1 x skin prick tests is low to confirme the eczematic reaction in patients suffering from allergy to inhallant allergens.

  3. Carpal tunnel syndrome: Investigating the sensitivity of initial-diagnosis with electro-diagnostic tests in 600 cases and associated risk factors especially manual milking.

    PubMed

    Tunç, Abdulkadir; Güngen, Belma Doğan

    2017-01-01

    Electro-diagnostic studies are the most reliable methods in diagnosis of carpal tunnel syndrome (CTS). Although there are many risk factors associated with CTS, there are a limited number of studies in the literature indicating that manual milking, which is frequently seen in Turkey, is a risk factor for CTS. The purpose of this study was to evaluate demographic findings of cases referred due to initial diagnosis of CTS as well as aetiological data especially manual milking and to investigate the sensitivity of initial diagnosis of CTS. Six hundred patients, who were referred to our electromyography laboratory due to initial diagnosis of CTS, were included. Demographic findings, duration of complaints, existence of diabetes mellitus, and manual milking histories of all patients were recorded. Sensitivity of initial diagnosis was investigated based on electro-diagnostic test results. According to electro-diagnostic test results, 289 of the patients were diagnosed with CTS (48.17%). 110 (18.3%) of 600 patients had a history of manual milking. In 94 of this group (85.4%), CTS was detected. Statistically significant correlation was found between CTS and age, female gender, duration of complaints, obesity and manual milking. This study confirms that manual milking is an important risk factor for CTS in addition to female gender, age, symptom duration and obesity. The fact that sensitivity of initial diagnosis of CTS was found to be low according to electro-diagnostic test results indicates importance of detailed clinical evaluation.

  4. Laboratory diagnosis of Ebola virus disease and corresponding biosafety considerations in the China Ebola Treatment Center.

    PubMed

    Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing

    2016-10-01

    Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.

  5. Comparative study on the efficiency of some optical methods for artwork diagnostics

    NASA Astrophysics Data System (ADS)

    Schirripa Spagnolo, Giuseppe; Ambrosini, Dario; Paoletti, Domenica

    2001-10-01

    Scientific investigation methods are founding their place besides the stylistic-historical study methods in art research works. In particular, optical techniques, transferred from other fields or developed ad hoc, can make a strong contribution to the safeguarding and exploitation of cultural heritage. This paper describes the use of different optical techniques, such as holographic interferometry, decorrelation, shearography and ESPI, in the diagnostics of works of art. A comparison between different methods is obtained by performing tests on specially designed models, prepared using typical techniques and materials. Inside the model structure, a number of defects of known types, form and extension are inserted. The different features of each technique are outlined and a comparison with IR thermography is also carried out.

  6. 49 CFR 395.16 - Electronic on-board recording devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transfer through wired and wireless methods to portable computers used by roadside safety assurance... the results of power-on self-tests and diagnostic error codes. (e) Date and time. (1) The date and... part. Wireless communication information interchange methods must comply with the requirements of the...

  7. Noninvasive Diagnosis of Visceral Leishmaniasis: Development and Evaluation of Two Urine-Based Immunoassays for Detection of Leishmania donovani Infection in India

    PubMed Central

    Ejazi, Sarfaraz Ahmad; Bhattacharya, Pradyot; Bakhteyar, Md. Asjad Karim; Mumtaz, Aquil Ahmad; Pandey, Krishna; Das, Vidya Nand Ravi; Das, Pradeep; Rahaman, Mehebubar; Goswami, Rama Prosad; Ali, Nahid

    2016-01-01

    Background Visceral Leishmaniasis (VL), a severe parasitic disease, could be fatal if diagnosis and treatment is delayed. Post kala-azar dermal leishmaniasis (PKDL), a skin related outcome, is a potential reservoir for the spread of VL. Diagnostic tests available for VL such as tissue aspiration are invasive and painful although they are capable of evaluating the treatment response. Serological tests although less invasive than tissue aspiration are incompetent to assess cure. Parasitological examination of slit-skin smear along with the clinical symptoms is routinely used for diagnosis of PKDL. Therefore, a noninvasive test with acceptable sensitivity and competency, additionally, to decide cure would be an asset in disease management and control. Methodology/principal findings We describe here, the development of antibody-capture ELISA and field adaptable dipstick test as noninvasive diagnostic tools for VL and PKDL and as a test of cure in VL treatment. Sensitivity and specificity of urine-ELISA were 97.94% (95/97) and 100% (75/75) respectively, for VL. Importantly, dipstick test demonstrated 100% sensitivity (97/97) and specificity (75/75) in VL diagnosis. Degree of agreement of the two methods with tissue aspiration was 98.83% (κ = 0.97) and 100% (κ = 1), for ELISA and dipstick test, respectively. Both the tests had 100% positivity for PKDL (14/14) cases. ELISA and dipstick test illustrated treatment efficacy in about 90% (16/18) VL cases when eventually turned negative after six months of treatment. Conclusions/significance ELISA and dipstick test found immensely effective for diagnosis of VL and PKDL through urine samples thus, may substitute the existing invasive diagnostics. Utility of these tests as indirect methods of monitoring parasite clearance can define infected versus cured. Urine-based dipstick test is simple, sensitive and above all noninvasive method that may help not only in active VL case detection but also to ascertain treatment response. It can therefore, be deployed widely for interventions in disease management of VL particularly in poor resource outskirts. PMID:27741241

  8. WHAT ARE THE Omh {sup 2} ( z {sub 1}, z {sub 2}) AND Om ( z {sub 1}, z {sub 2}) DIAGNOSTICS TELLING US IN LIGHT OF H ( z ) DATA?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Xiaogang; Ding, Xuheng; Biesiada, Marek

    2016-07-01

    The two-point diagnostics Om ( z {sub i} , z {sub j} ) and Omh {sup 2}( z {sub i} , z {sub j} ) have been introduced as an interesting tool for testing the validity of the Λ cold dark matter (ΛCDM) model. Recently, Sahni et al. combined two independent measurements of H ( z ) from baryon acoustic oscillation (BAO) data with the value of the Hubble constant H {sub 0}, and used the second of these diagnostics to test the ΛCDM (a constant equation-of-state parameter for dark energy) model. Their result indicated a considerable tension between observationsmore » and predictions of the ΛCDM model. Since reliable data concerning the expansion rates of the universe at different redshifts H ( z ) are crucial for the successful application of this method, we investigate both two-point diagnostics on the most comprehensive set of N = 36 measurements of H ( z ) from BAOs and the differential ages (DAs) of passively evolving galaxies. We discuss the uncertainties of the two-point diagnostics and find that they are strongly non-Gaussian and follow the patterns deeply rooted in their very construction. Therefore we propose that non-parametric median statistics is the most appropriate way of treating this problem. Our results support the claims that ΛCDM is in tension with H ( z ) data according to the two-point diagnostics developed by Shafieloo, Sahni, and Starobinsky. However, other alternatives to the ΛCDM model, such as the wCDM or Chevalier–Polarski–Linder models, perform even worse. We also note that there are serious systematic differences between the BAO and DA methods that ought to be better understood before H ( z ) measurements can compete with other probes methods.« less

  9. Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis

    PubMed Central

    El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas

    2014-01-01

    Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard. PMID:24218531

  10. Development of computer informational system of diagnostics integrated optical materials, elements, and devices

    NASA Astrophysics Data System (ADS)

    Volosovitch, Anatoly E.; Konopaltseva, Lyudmila I.

    1995-11-01

    Well-known methods of optical diagnostics, database for their storage, as well as expert system (ES) for their development are analyzed. A computer informational system is developed, which is based on a hybrid ES built on modern DBMS. As an example, the structural and constructive circuits of the hybrid integrated-optical devices based on laser diodes, diffusion waveguides, geodetic lenses, package-free linear photodiode arrays, etc. are presented. The features of methods and test results as well as the advanced directions of works related to the hybrid integrated-optical devices in the field of metrology are discussed.

  11. Diagnostics for insufficiencies of posterior calculations in Bayesian signal inference.

    PubMed

    Dorn, Sebastian; Oppermann, Niels; Ensslin, Torsten A

    2013-11-01

    We present an error-diagnostic validation method for posterior distributions in Bayesian signal inference, an advancement of a previous work. It transfers deviations from the correct posterior into characteristic deviations from a uniform distribution of a quantity constructed for this purpose. We show that this method is able to reveal and discriminate several kinds of numerical and approximation errors, as well as their impact on the posterior distribution. For this we present four typical analytical examples of posteriors with incorrect variance, skewness, position of the maximum, or normalization. We show further how this test can be applied to multidimensional signals.

  12. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid-Heat LAMPellet method and has the potential to be developed further as a field diagnostic tool for use in urogenital schistosomiasis-endemic areas. PMID:26230990

  13. A systematic review of the clinical, public health and cost-effectiveness of rapid diagnostic tests for the detection and identification of bacterial intestinal pathogens in faeces and food.

    PubMed

    Abubakar, I; Irvine, L; Aldus, C F; Wyatt, G M; Fordham, R; Schelenz, S; Shepstone, L; Howe, A; Peck, M; Hunter, P R

    2007-09-01

    To determine the diagnostic accuracy of tests for the rapid diagnosis of bacterial food poisoning in clinical and public health practice and to estimate the cost-effectiveness of these assays in a hypothetical population in order to inform policy on the use of these tests. Studies evaluating diagnostic accuracy of rapid tests were retrieved using electronic databases and handsearching reference lists and key journals. Hospital laboratories and test manufacturers were contacted for cost data, and clinicians involved in the care of patients with food poisoning were invited to discuss the conclusions of this review using the nominal group technique. A systematic review of the current medical literature on assays used for the rapid diagnosis of bacterial food poisoning was carried out. Specific organisms under review were Salmonella, Campylobacter, Escherichia coli O157, Staphylococcus aureus, Clostridium perfringens and Bacillus cereus. Data extraction was undertaken using standardised data extraction forms. Where a sufficient number of studies evaluating comparable tests were identified, meta-analysis was performed. A decision analytic model was developed, using effectiveness data from the review and cost data from hospitals and manufacturers, which contributed to an assessment of the cost-effectiveness of rapid tests in a hypothetical UK population. Finally, diagnostic accuracy and cost-effectiveness results were presented to a focus group of GPs, microbiologists and consultants in communicable disease control, to assess professional opinion on the use of rapid tests in the diagnosis of food poisoning. Good test performance levels were observed with rapid test methods, especially for polymerase chain reaction (PCR) assays. The estimated levels of diagnostic accuracy using the area under the curve of the summary receiver operating characteristic curve was very high. Indeed, although traditional culture is the natural reference test to use for comparative statistical analysis, on many occasions the rapid test outperforms culture, detecting additional 'truly' positive cases of food-borne illness. The significance of these additional positives requires further investigation. Economic modelling suggests that adoption of rapid tests in combination with routine culture is unlikely to be cost-effective, however, as the cost of rapid technologies decreases; total replacement with rapid technologies may be feasible. Despite the relatively poor quality of reporting of studies evaluating rapid detection methods, the reviewed evidence shows that PCR for Campylobacter, Salmonella and E. coli O157 is potentially very successful in identifying pathogens, possibly detecting more than the number currently reported using culture. Less is known about the benefits of testing for B. cereus, C. perfringens and S. aureus. Further investigation is needed on how clinical outcomes may be altered if test results are available more quickly and at a greater precision than in the current practice of bacterial culture.

  14. Limited-information goodness-of-fit testing of diagnostic classification item response models.

    PubMed

    Hansen, Mark; Cai, Li; Monroe, Scott; Li, Zhen

    2016-11-01

    Despite the growing popularity of diagnostic classification models (e.g., Rupp et al., 2010, Diagnostic measurement: theory, methods, and applications, Guilford Press, New York, NY) in educational and psychological measurement, methods for testing their absolute goodness of fit to real data remain relatively underdeveloped. For tests of reasonable length and for realistic sample size, full-information test statistics such as Pearson's X 2 and the likelihood ratio statistic G 2 suffer from sparseness in the underlying contingency table from which they are computed. Recently, limited-information fit statistics such as Maydeu-Olivares and Joe's (2006, Psychometrika, 71, 713) M 2 have been found to be quite useful in testing the overall goodness of fit of item response theory models. In this study, we applied Maydeu-Olivares and Joe's (2006, Psychometrika, 71, 713) M 2 statistic to diagnostic classification models. Through a series of simulation studies, we found that M 2 is well calibrated across a wide range of diagnostic model structures and was sensitive to certain misspecifications of the item model (e.g., fitting disjunctive models to data generated according to a conjunctive model), errors in the Q-matrix (adding or omitting paths, omitting a latent variable), and violations of local item independence due to unmodelled testlet effects. On the other hand, M 2 was largely insensitive to misspecifications in the distribution of higher-order latent dimensions and to the specification of an extraneous attribute. To complement the analyses of the overall model goodness of fit using M 2 , we investigated the utility of the Chen and Thissen (1997, J. Educ. Behav. Stat., 22, 265) local dependence statistic XLD2 for characterizing sources of misfit, an important aspect of model appraisal often overlooked in favour of overall statements. The XLD2 statistic was found to be slightly conservative (with Type I error rates consistently below the nominal level) but still useful in pinpointing the sources of misfit. Patterns of local dependence arising due to specific model misspecifications are illustrated. Finally, we used the M 2 and XLD2 statistics to evaluate a diagnostic model fit to data from the Trends in Mathematics and Science Study, drawing upon analyses previously conducted by Lee et al., (2011, IJT, 11, 144). © 2016 The British Psychological Society.

  15. Diagnostic value of ST-segment deviations during cardiac exercise stress testing: Systematic comparison of different ECG leads and time-points.

    PubMed

    Puelacher, Christian; Wagener, Max; Abächerli, Roger; Honegger, Ursina; Lhasam, Nundsin; Schaerli, Nicolas; Prêtre, Gil; Strebel, Ivo; Twerenbold, Raphael; Boeddinghaus, Jasper; Nestelberger, Thomas; Rubini Giménez, Maria; Hillinger, Petra; Wildi, Karin; Sabti, Zaid; Badertscher, Patrick; Cupa, Janosch; Kozhuharov, Nikola; du Fay de Lavallaz, Jeanne; Freese, Michael; Roux, Isabelle; Lohrmann, Jens; Leber, Remo; Osswald, Stefan; Wild, Damian; Zellweger, Michael J; Mueller, Christian; Reichlin, Tobias

    2017-07-01

    Exercise ECG stress testing is the most widely available method for evaluation of patients with suspected myocardial ischemia. Its major limitation is the relatively poor accuracy of ST-segment changes regarding ischemia detection. Little is known about the optimal method to assess ST-deviations. A total of 1558 consecutive patients undergoing bicycle exercise stress myocardial perfusion imaging (MPI) were enrolled. Presence of inducible myocardial ischemia was adjudicated using MPI results. The diagnostic value of ST-deviations for detection of exercise-induced myocardial ischemia was systematically analyzed 1) for each individual lead, 2) at three different intervals after the J-point (J+40ms, J+60ms, J+80ms), and 3) at different time points during the test (baseline, maximal workload, 2min into recovery). Exercise-induced ischemia was detected in 481 (31%) patients. The diagnostic accuracy of ST-deviations was highest at +80ms after the J-point, and at 2min into recovery. At this point, ST-amplitude showed an AUC of 0.63 (95% CI 0.59-0.66) for the best-performing lead I. The combination of ST-amplitude and ST-slope in lead I did not increase the AUC. Lead I reached a sensitivity of 37% and a specificity of 83%, with similar sensitivity to manual ECG analysis (34%, p=0.31) but lower specificity (90%, p<0.001). When using ECG stress testing for evaluation of patients with suspected myocardial ischemia, the diagnostic accuracy of ST-deviations is highest when evaluated at +80ms after the J-point, and at 2min into recovery. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Field evaluation of a recombinase polymerase amplification assay for the diagnosis of Schistosoma japonicum infection in Hunan province of China.

    PubMed

    Xing, Weiwei; Yu, Xinling; Feng, Jingtao; Sun, Kui; Fu, Wenliang; Wang, Yuanyuan; Zou, Minji; Xia, Wenrong; Luo, Zhihong; He, Hongbin; Li, Yuesheng; Xu, Donggang

    2017-02-21

    Current diagnostic methods for Schistosoma japonicum infection are insensitive for low-density infections. Therefore, a new diagnostic assay based on recombinase polymerase amplification (RPA) technology was established and assessed for field applification. The S.japonicum RPA assay was developed to target highly repetitive retrotransposon SjR2 gene of S japonicum, and its sensitivity and specificity were assessed by serial dilution of S. japonicum genomic DNA and other related worm genomic DNA respectively. The RPA diagnostic validity was first evaluated in 60 fecal samples from healthy people and patients, and then compared with other diagnostic tests in 200 high-risk individuals living in endemic areas. The real time RPA assay could detect 0.9 fg S. japonicum DNA within 15 min and distinguish S. japonicum from other worms. The validity analysis of RPA for the detection of S. japonicum in stool samples from 30 S. japonicum-infected patients and 30 healthy persons indicated 100% sensitivity and specificity. When testing 200 fecal or serum samples from a high-risk population, the percentage sensitivity of RPA was 100%, whereas that of indirect hemagglutination assay (IHA) and enzyme-linked immunosorbent assay (ELISA) were 80.3% and 85.2% respectively. In addition, the RPA presented better consistency with the stool-based tests than IHA and ELISA. Overall, the RPA was superior to other detection methods with respect to detection time, sensitivity, and convenience. This is the first time we applied the RPA technology to the field evaluation of S. japonicum infection. And the results suggest that RPA-based assays can be used as a promising point-of-care test for the diagnosis of schistosomiasis.

  17. Diagnosis of scrub typhus.

    PubMed

    Janardhanan, Jeshina; Trowbridge, Paul; Varghese, George M

    2014-12-01

    Scrub typhus is an acute febrile illness that, if untreated, can result in considerable morbidity and mortality. One of the primary reasons for delays in the treatment of this potentially fatal infection is the difficulty in diagnosing the condition. Diagnosis is often complicated because of the combination of non-specific symptoms that overlap with other infections commonly found in endemic areas and the poor available diagnostics. In the majority of the endemic settings, diagnosis still relies on the Weil-Felix test, which is neither sensitive nor specific. Other methods of testing have become available, but at this time, these remain insufficient to provide the rapid point-of-care diagnostics that would be necessary to significantly change the management of this infection by providers in endemic areas. This article reviews the currently available diagnostic tools for scrub typhus and their utility in the clinical setting.

  18. Patch testers' opinions regarding diagnostic criteria for metal hypersensitivity reactions to metallic implants.

    PubMed

    Schalock, Peter C; Thyssen, Jacob P

    2013-01-01

    Metal hypersensitivity reactions to implanted devices remain a challenging and controversial topic. Diagnostic criteria and methods are not well delineated. Diagnostic criteria for hypersensitivity reactions after metallic device implantation are evaluated in this study by a multinational group of patch testers using Thyssen's previously published criteria. A total of 119 dermatologists at the 2012 European Contact Dermatitis Society and 2013 American Contact Dermatitis Society meetings answered a survey regarding their opinions on topics relating to metal hypersensitivity. Four major and 5 minor diagnostic criteria emerged. Approximately 80% of respondents found the following criteria useful (major criteria): chronic dermatitis beginning weeks to months after metallic implantation, eruption overlying the metal implant, positive patch test to a metal component of the implant, and complete clearing after removal of the potentially allergenic implant. Minor criteria (<61% of respondents) were as follows: systemic allergic dermatitis reaction, therapy-resistant dermatitis, morphology consistent with dermatitis, histology consistent with allergic contact dermatitis, and a positive in vitro test to metals (eg, lymphocyte transformation test). In the challenging situation such as a symptomatic or failing orthopedic device, applying these 4 major criteria and the 5 supportive minor criteria may be useful for guiding decision making.

  19. Verification and classification bias interactions in diagnostic test accuracy studies for fine-needle aspiration biopsy.

    PubMed

    Schmidt, Robert L; Walker, Brandon S; Cohen, Michael B

    2015-03-01

    Reliable estimates of accuracy are important for any diagnostic test. Diagnostic accuracy studies are subject to unique sources of bias. Verification bias and classification bias are 2 sources of bias that commonly occur in diagnostic accuracy studies. Statistical methods are available to estimate the impact of these sources of bias when they occur alone. The impact of interactions when these types of bias occur together has not been investigated. We developed mathematical relationships to show the combined effect of verification bias and classification bias. A wide range of case scenarios were generated to assess the impact of bias components and interactions on total bias. Interactions between verification bias and classification bias caused overestimation of sensitivity and underestimation of specificity. Interactions had more effect on sensitivity than specificity. Sensitivity was overestimated by at least 7% in approximately 6% of the tested scenarios. Specificity was underestimated by at least 7% in less than 0.1% of the scenarios. Interactions between verification bias and classification bias create distortions in accuracy estimates that are greater than would be predicted from each source of bias acting independently. © 2014 American Cancer Society.

  20. Deployment of a Reverse Transcription Loop-Mediated Isothermal Amplification Test for Ebola Virus Surveillance in Remote Areas in Guinea.

    PubMed

    Kurosaki, Yohei; Magassouba, N'Faly; Bah, Hadja Aïssatou; Soropogui, Barré; Doré, Amadou; Kourouma, Fodé; Cherif, Mahamoud Sama; Keita, Sakoba; Yasuda, Jiro

    2016-10-15

    To strengthen the laboratory diagnostic capacity for Ebola virus disease (EVD) in the remote areas of Guinea, we deployed a mobile field laboratory and implemented reverse transcription loop-mediated isothermal amplification (RT-LAMP) for postmortem testing. We tested 896 oral swab specimens and 21 serum samples, using both RT-LAMP and reverse transcription-polymerase chain reaction (RT-PCR). Neither test yielded a positive result, and the results from RT-LAMP and RT-PCR were consistent. More than 95% of the samples were tested within 2 days of sample collection. These results highlight the usefulness of the RT-LAMP assay as an EVD diagnostic testing method in the field or remote areas. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  1. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...

  2. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...

  3. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false On-board diagnostic test equipment... Warranty Short Tests § 85.2231 On-board diagnostic test equipment requirements. (a) The test system interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The...

  4. 40 CFR 85.2222 - On-board diagnostic test procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false On-board diagnostic test procedures... Warranty Short Tests § 85.2222 On-board diagnostic test procedures. The test sequence for the inspection of on-board diagnostic systems on 1996 and newer light-duty vehicles and light-duty trucks shall consist...

  5. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false On-board diagnostic test equipment... Warranty Short Tests § 85.2231 On-board diagnostic test equipment requirements. (a) The test system interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The...

  6. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false On-board diagnostic test equipment... Warranty Short Tests § 85.2231 On-board diagnostic test equipment requirements. (a) The test system interface to the vehicle shall include a plug that conforms to SAE J1962 “Diagnostic Connector.” The...

  7. Non-invasive 13C-glucose breath test using residual gas analyzer-mass spectrometry: a novel tool for screening individuals with pre-diabetes and type 2 diabetes.

    PubMed

    Ghosh, Chiranjit; Maity, Abhijit; Banik, Gourab D; Som, Suman; Chakraborty, Arpita; Selvan, Chitra; Ghosh, Shibendu; Ghosh, Barnali; Chowdhury, Subhankar; Pradhan, Manik

    2014-09-01

    We report, for the first time, the clinical feasibility of a novel residual gas analyzer mass spectrometry (RGA-MS) method for accurate evaluation of the (13)C-glucose breath test ((13)C-GBT) in the diagnosis of pre-diabetes (PD) and type 2 diabetes mellitus (T2D). In T2D or PD, glucose uptake is impaired and results in blunted isotope enriched (13)CO2 production in exhaled breath samples. Using the Receiver operating characteristics (ROC) curve analysis, an optimal diagnostic cut-off point of the (13)CO2/(12)CO2 isotope ratios expressed as the delta-over-baseline (DOB) value, was determined to be δDOB(13)C‰ = 28.81‰ for screening individuals with non-diabetes controls (NDC) and pre-diabetes (PD), corresponding to a sensitivity of 100% and specificity of 94.4%. We also determined another optimal diagnostic cut-off point of δDOB(13)C‰ = 19.88‰ between individuals with PD and T2D, which exhibited 100% sensitivity and 95.5% specificity. Our RGA-MS methodology for the (13)C-GBT also manifested a typical diagnostic positive and negative predictive value of 96% and 100%, respectively. The diagnostic accuracy, precision and validity of the results were also confirmed by high-resolution optical cavity enhanced integrated cavity output spectroscopy (ICOS) measurements. The δDOB(13)C‰ values measured with RGA-MS method, correlated favourably (R(2) = 0.979) with those determined by the laser based ICOS method. Moreover, we observed that the effects of endogenous CO2 production related to basal metabolic rates in individuals were statistically insignificant (p = 0.37 and 0.73) on the diagnostic accuracy. Our findings suggest that the RGA-MS is a valid and sufficiently robust method for the (13)C-GBT which may serve as an alternative non-invasive point-of-care diagnostic tool for routine clinical practices as well as for large-scale diabetes screening purposes in real-time.

  8. The clinical evaluation of infantile nystagmus: What to do first and why

    PubMed Central

    Bertsch, Morgan; Floyd, Michael; Kehoe, Taylor; Pfeifer, Wanda; Drack, Arlene V.

    2017-01-01

    Introduction Infantile nystagmus has many causes, some life threatening. We determined the most common diagnoses in order to develop a testing algorithm. Methods Retrospective chart review. Exclusion criteria were no nystagmus, acquired after 6 months, or lack of examination. Data collected: pediatric eye examination findings, ancillary testing, order of testing, referral, and final diagnoses. Final diagnosis was defined as meeting published clinical criteria and/or confirmed by diagnostic testing. Patients with a diagnosis not meeting the definition were “unknown.” Patients with incomplete testing were “incomplete.” Patients with multiple plausible etiologies were “multifactorial.” Patients with negative complete workup were “motor.” Results 284 charts were identified; 202 met inclusion criteria. The 3 most common causes were Albinism(19%), Leber Congenital Amaurosis(LCA)(14%) and Non-LCA retinal dystrophy (13%). Anatomic retinal disorders comprised 10%, motor another 10%. The most common first test was MRI (74/202) with a diagnostic yield of 16%. For 28 MRI-first patients, nystagmus alone was the indication; for 46 MRI-first patients other neurologic signs were present. 0/28 nystagmus-only patients had a diagnostic MRI while 14/46 (30%) with neurologic signs did. Yield of ERG as first test was 56%, OCT 55%, and molecular genetic testing 47%. 90% of patients had an etiology identified. Conclusion The most common causes of infantile nystagmus were retinal disorders (56%), however the most common first test was brain MRI. For patients without other neurologic stigmata complete pediatric eye examination, ERG, OCT and molecular genetic testing had a higher yield than MRI scan. If MRI is not diagnostic, a complete ophthalmologic workup should be pursued. PMID:28177849

  9. Applying team-based learning of diagnostics for undergraduate students: assessing teaching effectiveness by a randomized controlled trial study.

    PubMed

    Zeng, Rui; Xiang, Lian-Rui; Zeng, Jing; Zuo, Chuan

    2017-01-01

    We aimed to introduce team-based learning (TBL) as one of the teaching methods for diagnostics and to compare its teaching effectiveness with that of the traditional teaching methods. We conducted a randomized controlled trial on diagnostics teaching involving 111 third-year medical undergraduates, using TBL as the experimental intervention, compared with lecture-based learning as the control, for teaching the two topics of symptomatology. Individual Readiness Assurance Test (IRAT)-baseline and Group Readiness Assurance Test (GRAT) were performed in members of each TBL subgroup. The scores in Individual Terminal Test 1 (ITT1) immediately after class and Individual Terminal Test 2 (ITT2) 1 week later were compared between the two groups. The questionnaire and interview were also implemented to survey the attitude of students and teachers toward TBL. There was no significant difference between the two groups in ITT1 (19.85±4.20 vs 19.70±4.61), while the score of the TBL group was significantly higher than that of the control group in ITT2 (19.15±3.93 vs 17.46±4.65). In the TBL group, the scores of the two terminal tests after the teaching intervention were significantly higher than the baseline test score of individuals. IRAT-baseline, ITT1, and ITT2 scores of students at different academic levels in the TBL teaching exhibited significant differences, but the ITT1-IRAT-baseline and ITT2-IRAT-baseline indicated no significant differences among the three subgroups. Our TBL in symptomatology approach was highly accepted by students in the improvement of interest and self-directed learning and resulted in an increase in knowledge acquirements, which significantly improved short-term test scores compared with lecture-based learning. TBL is regarded as an effective teaching method worthy of promoting.

  10. A comparative study of the diagnostic methods for Group A streptococcal sore throat in two reference hospitals in Yaounde, Cameroon

    PubMed Central

    Gonsu, Hortense Kamga; Bomki, Cynthia Mbimenyuy; Djomou, François; Toukam, Michel; Ndze, Valantine Ngum; Lyonga, Emilia Enjema; Mbakop, Calixte Didier; Koulla-Shiro, Sinata

    2015-01-01

    Introduction Sore throat is a common complaint in general practice which is more frequent in children. The most frequent pathogenic bacteria associated with this infection is Streptococcus pyogenes. Rapid Antigen Diagnostic Test (RADT) facilitates the rapid identification and consequently prompt treatment of patients, prevents complications, and also reduces the risk of spread of Group A Streptococcus (GAS). The main objective of this study was to assess the diagnostic value of a rapid streptococcal antigen detection test in patients with sore throat. Methods A cross-sectional descriptive study was carried out from January to April 2011 on patients aged 3 to 72 years consulting for pharyngitis or sore throat at the paediatric and Ear, Nose and Throat units of the University Teaching Hospital Yaounde and the Central Hospital Yaounde. Two throat swabs were collected per patient. One was used for the rapid test and the other for standard bacteriological analysis. Results The prevalence of GAS in the study population was 22.5%. Out of the 71 samples collected, the RADT detected group A streptococcal antigens in 12 of 16 positive cultures giving a sensitivity of 75%. The specificity of the rapid test was 96%, with positive predictive value of 85.7%, and negative predictive value of 93% respectively. Conclusion Rapid test may have an additional value in the management of patients with high risk of having GAS infection. However, tests with a higher sensitivity are needed for accurate and reliable results for early diagnosis of patients with sore throat caused by GAS. PMID:27386017

  11. A Simplified Diagnostic Method for Elastomer Bond Durability

    NASA Technical Reports Server (NTRS)

    White, Paul

    2009-01-01

    A simplified method has been developed for determining bond durability under exposure to water or high humidity conditions. It uses a small number of test specimens with relatively short times of water exposure at elevated temperature. The method is also gravimetric; the only equipment being required is an oven, specimen jars, and a conventional laboratory balance.

  12. Epidemiology of angina pectoris: role of natural language processing of the medical record

    PubMed Central

    Pakhomov, Serguei; Hemingway, Harry; Weston, Susan A.; Jacobsen, Steven J.; Rodeheffer, Richard; Roger, Véronique L.

    2007-01-01

    Background The diagnosis of angina is challenging as it relies on symptom descriptions. Natural language processing (NLP) of the electronic medical record (EMR) can provide access to such information contained in free text that may not be fully captured by conventional diagnostic coding. Objective To test the hypothesis that NLP of the EMR improves angina pectoris (AP) ascertainment over diagnostic codes. Methods Billing records of in- and out-patients were searched for ICD-9 codes for AP, chronic ischemic heart disease and chest pain. EMR clinical reports were searched electronically for 50 specific non-negated natural language synonyms to these ICD-9 codes. The two methods were compared to a standardized assessment of angina by Rose questionnaire for three diagnostic levels: unspecified chest pain, exertional chest pain, and Rose angina. Results Compared to the Rose questionnaire, the true positive rate of EMR-NLP for unspecified chest pain was 62% (95%CI:55–67) vs. 51% (95%CI:44–58) for diagnostic codes (p<0.001). For exertional chest pain, the EMR-NLP true positive rate was 71% (95%CI:61–80) vs. 62% (95%CI:52–73) for diagnostic codes (p=0.10). Both approaches had 88% (95%CI:65–100) true positive rate for Rose angina. The EMR-NLP method consistently identified more patients with exertional chest pain over 28-month follow-up. Conclusion EMR-NLP method improves the detection of unspecified and exertional chest pain cases compared to diagnostic codes. These findings have implications for epidemiological and clinical studies of angina pectoris. PMID:17383310

  13. Sixty-five years since the New York heat wave: advances in sweat testing for cystic fibrosis.

    PubMed

    Collie, Jake T B; Massie, R John; Jones, Oliver A H; LeGrys, Vicky A; Greaves, Ronda F

    2014-02-01

    The sweat test remains important as a diagnostic test for cystic fibrosis (CF) and has contributed greatly to our understanding of CF as a disease of epithelial electrolyte transport. The standardization of the sweat test, by Gibson and Cooke [Gibson and Cooke (1959) Pediatrics 1959;23:5], followed observations of excessive dehydration amongst patients with CF and confirmed the utility as a diagnostic test. Quantitative pilocarpine iontophoresis remains the gold standard for sweat induction, but there are a number of collection and analytical methods. The pathophysiology of electrolyte transport in sweat was described by Quinton [Quinton (1983) Nature 1983;301:421-422], and this complemented the developments in genetics that discovered the cystic fibrosis transmembrane conductance regulator (CFTR), an epithelial-based electrolyte transport protein. Knowledge of CF has since increased rapidly and further developments in sweat testing include: new collection methods, further standardization of the technique with international recommendations and age related reference intervals. More recently, sweat chloride values have been used as proof of effect for the new drugs that activate CFTR. However, there remain issues with adherence to sweat test guidelines in many countries and there are gaps in our knowledge, including reference intervals for some age groups and stability of sweat samples in transport. Furthermore, modern methods of elemental quantification need to be explored as alternatives to the original analytical methods for sweat electrolyte measurement. The purpose of this review is therefore to describe the development of the sweat test and consider future directions. © 2013 Wiley Periodicals, Inc.

  14. [Molecular diagnostics of ALK-positive lung cancer].

    PubMed

    Tímár, József; Lotz, Gábor; Rásó, Erzsébet; Moldvay, Judit

    2017-09-20

    ALK translocation is the 3rd most frequent genetic aberration in lung adenocarcinoma, and several inhibitors are now clinically available in first and second line settings. Accordingly, molecular diagnostics of ALK-positive lung cancer is very important and can be done with the rational combination of several methods. All international recommendations suggest that, except for cytological samples, screening technology for ALK-positive tumors is immunohistochemistry using a validated test. It is highly recommended that in case of ALK protein positive samples gene translocation must be confirmed by fluorescent in situ hybridization (FISH). In case of cytological samples FISH technique must be used as ALK diagnostics. In equivocal cases the genetic alteration of ALK can be confirmed by alternative molecular techniques such as next generation sequencing or RNAbased PCR methods. Upon administration of ALK inhibitors, acquired resistance is frequent which is mostly due to ALK amplification and/or mutation. It is evident that the diagnostics of these secondary ALK gene alterations must be done from recurrent tumors or circulating nucleic acids.

  15. Point of Care- A Novel Approach to Periodontal Diagnosis-A Review

    PubMed Central

    Nayak, Prathibha Anand; Rana, Shivendra

    2017-01-01

    Periodontal disease, one of the prevalent oral diseases, is characterized by gingival inflammation and periodontal tissue destruction. Diagnosing this disease is challenging to the clinicians as the disease process is discontinuous and shows periods of exacerbation and remission. Traditional diagnostic methods basically tells about the past tissue destruction so new diagnostic methods are required which is able to detect the active state of the disease, determine the future progression and also estimates the response to the therapy, thereby helping in the better clinical management of the patient. Both saliva and Gingival crevicular fluid (GCF) are believed to be reliable medium to detect the biomarkers which plays a pivotal role in measuring the disease activity. Keeping these observations in mind rapid chairside tests are developed to diagnose periodontal disease called as Point of Care (POC) diagnostics which simplifies diagnosis and helps in improving the prognosis. This review article highlights about the biomarkers used in the diagnosis and throws light on the various available point of care diagnostic devices. PMID:28969294

  16. Diagnostic and Prognostic Value of Human Prion Detection in Cerebrospinal Fluid

    PubMed Central

    Foutz, Aaron; Appleby, Brian S.; Hamlin, Clive; Liu, Xiaoqin; Yang, Sheng; Cohen, Yvonne; Chen, Wei; Blevins, Janis; Fausett, Cameron; Wang, Han; Gambetti, Pierluigi; Zhang, Shulin; Hughson, Andrew; Tatsuoka, Curtis; Schonberger, Lawrence B.; Cohen, Mark L.; Caughey, Byron; Safar, Jiri G.

    2016-01-01

    Objective Several prion amplification systems have been proposed for detection of prions in cerebrospinal fluid (CSF), most recently, the measurements of prion seeding activity with second-generation real-time quaking-induced conversion (RT-QuIC). The objective of this study was to investigate the diagnostic performance of the RT-QuIC prion test in the broad phenotypic spectrum of prion diseases. Methods We performed CSF RT-QuIC testing in 2,141 patients who had rapidly progressive neurological disorders, determined diagnostic sensitivity and specificity in 272 cases which were autopsied, and evaluated the impact of mutations and polymorphisms in the PRNP gene, and Type 1 or Type 2 of human prions on diagnostic performance. Results The 98.5% diagnostic specificity and 92% sensitivity of CSF RT-QuIC in a blinded retrospective analysis matched the 100% specificity and 95% sensitivity of a blind prospective study. The CSF RT-QuIC differentiated 94% of cases of sporadic Creutzfeldt-Jakob disease (sCJD) MM1 from the sCJD MM2 phenotype, and 80% of sCJD VV2 from sCJD VV1. The mixed prion type 1–2 and cases heterozygous for codon 129 generated intermediate CSF RT-QuIC patterns, while genetic prion diseases revealed distinct profiles for each PRNP gene mutation. Interpretation The diagnostic performance of the improved CSF RT-QuIC is superior to surrogate marker tests for prion diseases such as 14-3-3 and Tau proteins and together with PRNP gene sequencing, the test allows the major prion subtypes to be differentiated in vivo. This differentiation facilitates prediction of the clinicopathological phenotype and duration of the disease—two important considerations for envisioned therapeutic interventions. PMID:27893164

  17. What Is the Teacher Doing? What Are the Students Doing? An Application of the Draw-a-Science-Teacher-Test

    ERIC Educational Resources Information Center

    Minogue, James

    2010-01-01

    This study documents the use of the Draw-a-Science-Teacher-Test as diagnostic tool for both preservice teacher beliefs about science teaching and science methods course effectiveness. Direct comparison of pre-course to post-course images from 50 preservice elementary teachers was undertaken using McNemar's test. Results indicated statistically…

  18. Multidimensional Approach to the Development of a Mandarin Chinese-Oriented Sound Test

    ERIC Educational Resources Information Center

    Hung, Yu-Chen; Lin, Chun-Yi; Tsai, Li-Chiun; Lee, Ya-Jung

    2016-01-01

    Purpose: Because the Ling six-sound test is based on American English phonemes, it can yield unreliable results when administered to non-English speakers. In this study, we aimed to improve specifically the diagnostic palette for Mandarin Chinese users by developing an adapted version of the Ling six-sound test. Method: To determine the set of…

  19. Molecular Diagnostics in Transfusion Medicine: In Capillary, on a Chip, in Silico, or in Flight?

    PubMed Central

    Garritsen, Henk S.P.; Xiu-Cheng Fan, Alex; Lenz, Daniela; Hannig, Horst; Yan Zhong, Xiao; Geffers, Robert; Lindenmaier, Werner; Dittmar, Kurt E.J.; Wörmann, Bernhard

    2009-01-01

    Summary Serology, defined as antibody-based diagnostics, has been regarded as the diagnostic gold standard in transfusion medicine. Nowadays however the impact of molecular diagnostics in transfusion medicine is rapidly growing. Molecular diagnostics can improve tissue typing (HLA typing), increase safety of blood products (NAT testing of infectious diseases), and enable blood group typing in difficult situations (after transfusion of blood products or prenatal non-invasive RhD typing). Most of the molecular testing involves the determination of the presence of single nucleotide polymorphisms (SNPs). Antigens (e.g. blood group antigens) mostly result from single nucleotide differences in critical positions. However, most blood group systems cannot be determined by looking at a single SNP. To identify members of a blood group system a number of critical SNPs have to be taken into account. The platforms which are currently used to perform molecular diagnostics are mostly gel-based, requiring time-consuming multiple manual steps. To implement molecular methods in transfusion medicine in the future the development of higher-throughput SNP genotyping non-gel-based platforms which allow a rapid, cost-effective screening are essential. Because of its potential for automation, high throughput and cost effectiveness the special focus of this paper is a relative new technique: SNP genotyping by MALDI-TOF MS analysis. PMID:21113259

  20. The Quantitative Science of Evaluating Imaging Evidence.

    PubMed

    Genders, Tessa S S; Ferket, Bart S; Hunink, M G Myriam

    2017-03-01

    Cardiovascular diagnostic imaging tests are increasingly used in everyday clinical practice, but are often imperfect, just like any other diagnostic test. The performance of a cardiovascular diagnostic imaging test is usually expressed in terms of sensitivity and specificity compared with the reference standard (gold standard) for diagnosing the disease. However, evidence-based application of a diagnostic test also requires knowledge about the pre-test probability of disease, the benefit of making a correct diagnosis, the harm caused by false-positive imaging test results, and potential adverse effects of performing the test itself. To assist in clinical decision making regarding appropriate use of cardiovascular diagnostic imaging tests, we reviewed quantitative concepts related to diagnostic performance (e.g., sensitivity, specificity, predictive values, likelihood ratios), as well as possible biases and solutions in diagnostic performance studies, Bayesian principles, and the threshold approach to decision making. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Top