Vroblesky, Don A.; Pravecek, Tasha
2002-01-01
Field comparisons of chemical concentrations obtained from dialysis samplers, passive diffusion bag samplers, and low-flow samplers showed generally close agreement in most of the 13 wells tested during July 2001 at Hickam Air Force Base, Hawaii. The data for chloride, sulfate, iron, alkalinity, arsenic, and methane appear to show that the dialysis samplers are capable of accurately collecting a passive sample for these constituents. In general, the comparisons of volatile organic compound concentrations showed a relatively close correspondence between the two different types of diffusion samples and between the diffusion samples and the low-flow samples collected in most wells. Divergence appears to have resulted primarily from the pumping method, either producing a mixed sample or water not characteristic of aquifer water moving through the borehole under ambient conditions. The fact that alkalinity was not detected in the passive diffusion bag samplers, highly alkaline waters without volatilization loss from effervescence, which can occur when a sample is acidified for preservation. Both dialysis and passive diffusion bag samplers are relatively inexpensive and can be deployed rapidly and easily. Passive diffusion bag samplers are intended for sampling volatile organic compounds only, but dialysis samplers can be used to sample both volatile organic compounds and inorganic solutes. Regenerated cellulose dialysis samplers, however, are subject to biodegradation and probably should be deployed no sooner than 2 weeks prior to recovery. 1 U.S. Geological Survey, Columbia, South Carolina. 2 Air Florce Center for Environmental Excellence, San Antionio, Texas.
Zhou, Jianhui; Cao, Xueying; Lin, Hongli; Ni, Zhaohui; He, Yani; Chen, Menghua; Zheng, Hongguang; Chen, Xiangmei
2015-12-29
Peritoneal dialysis is an important type of renal replacement therapy for uremic patients. In peritoneal dialysis, fluids fill in and flow out of the abdominal cavity three to five times per day. Usually, the fluid is packed in a polyvinyl chloride (PVC) bag. Safety concerns have arisen over di-(2-ethylhexyl) phthalate, which is essential in the formation of PVC materials. In 2011, the National Development and Reform Commission of China released a catalog of industrial structural adjustments, mandating the elimination of PVC bags for intravenous infusion and food containers. Although bags for peritoneal dialysis fluid were not included in the elimination list, several manufacturers began to develop new materials for fluid bags. HUAREN peritoneal dialysis fluid consists of the same electrolytes and buffer agent as in Baxter fluid, but is packed in bags that do not contain PVC. This multicenter randomized controlled trial was designed to compare peritoneal dialysis fluid packed in non-PVC-containing and PVC-containing bags. Further, the study sought to determine the proper dose of peritoneal dialysis fluid and the actual survival rates of Chinese patients undergoing peritoneal dialysis. The study participants are adults undergoing continuous ambulatory peritoneal dialysis for 30 days to 6 months. All eligible patients are randomized (1:1) to peritoneal dialysis with Baxter and HUAREN dialysis fluids (initial dose, 6 l/day), with dosages adjusted according to a unified protocol. The primary outcomes are the 1-, 2-, 3-, 4-, and 5-year overall survival rates. Secondary outcome measures include technique survival rates, reductions in estimated glomerular filtration rate, nutritional status, quality of life, cardiovascular events, medical costs and drop-out rates. Safety outcome measures include adverse events, changes in vital signs and laboratory parameters, peritonitis, allergies, and quality of products. This study is the first to evaluate the long-term safety and effectiveness of a non-PVC packed peritoneal dialysis fluid. The effects of plasticizer on patient long-term survival will be determined. The characteristics of Chinese patients undergoing peritoneal dialysis will be determined, including proper dose, technique survival rates, patient survival rates, and medical costs. Clinicaltrials.gov NCT01779557 .
Kaye, Gordon; Weber, Peter; Evans, Ann; Venezia, Richard
1998-05-01
The efficacy of alkaline hydrolysis as an alternative for incineration or autoclaving during treatment and disposal of infectious waste was evaluated by testing for the destruction of samples of pure cultures of selected infectious microorganisms during digestion of 114 to 136-kg loads of animal carcasses in an animal tissue digestor at the Albany Medical College. Ten milliliter samples of pure cultures of each microorganism were divided among 3 dialysis bags made from narrow diameter dialysis tubing, and each of these bags was placed inside another dialysis bag made from larger diameter dialysis tubing. Each double-bagged sample was suspended from the cover of the carcass basket of the tissue digestor so that it was completely covered by hot alkaline digestion solution during the carcass digestion process. The following organisms were required by the New York State Department of Health as representative pathogens for testing sterilization capabilities of the procedure: Staphylococcus aureus, Mycobacterium fortuitum, Candida albicans, Bacillus subtilis, Pseudomonas aeruginosa, Aspergillus fumigatus, Mycobacterium bovis BCG, MS-2 bacteriophage, and Giardia muris. Animal carcasses included pigs, sheep, rabbits, dogs, rats, mice, and guinea pigs. The tissue digestor was operated at 110 to 120 C and approximately 15 lb/in2 (gauge) for 18 h before the system was allowed to cool to 50 C and dialysis bags were retrieved and submitted for microbial culture. None of the samples obtained from the dialysis bags after the digestion process yielded indicator bacteria or yeast. Giardia cysts were completely destroyed; only small fragments of what appeared to be cyst wall could be recognized with light microscopic examination. No plaque-forming units were detected with MS-2 bacteriophage after digestion. Samples of the hydrolyzate also did not yield growth on culture media. Animal carcasses were completely solubilized and digested, with only the inorganic components of the bones and teeth remaining after draining and rinsing of the digestion vessel. Alkaline hydrolysis, as performed in this tissue digestor, completely destroyed all representative classes of potentially infectious agents as well as disposing of animal carcasses by solubilization and digestion.
Fang, Pan; Lu, Jia; Liu, Ying-Hong; Deng, Hong-Mei; Zhang, Lei; Zhang, Hong-Qing
2018-06-01
Peritonitis, which is one of the leading complications of peritoneal dialysis (PD) worldwide, severely affected morbidity and mortality of the PD patients. Although many efforts have been made to prevent PD-related peritonitis, it seems impossible to prevent it completely. Many causes have been reported to lead to peritonitis, and contamination during bag exchange is one of the important risk factors for peritonitis. Here, we introduce an operating vehicle, which we invented to provide a sterile and safe space for bag exchange. A single-center, retrospective, case-control study was undertaken to determine whether this operating vehicle has a protective role in preventing peritonitis. In total, 462 continuous ambulatory peritoneal dialysis patients were included in this study from October 2014 to March 2017. According to their personal will, these patients chose to use operating vehicle or traditional method during their bag exchange. The demographic, clinical and laboratory data of these patients in the two groups were collected, analyzed and compared. Of 462 patients with home dialysis, operating vehicle group consisted of 61 patients, and control group consisted of 401 patients. In the control group, over 677 patient-years, peritonitis occurred in 69 of 401 patients (17.2%), while in the operating vehicle group, over 60 patient-years, only 4 of 61 patients (6.6%) had episodes of peritonitis. The number of patients suffered from peritonitis was significantly decreased in the operating vehicle group (P = 0.034). Besides, there were a total of 99 episodes of peritonitis, and the rate was 1 episode every 7.2 patient-years in control group and 1 episode every 12 patient-years in the operating vehicle group. There was significant difference between the two groups (0.013). Positive dialysate cultures were obtained in majority of the peritonitis episodes (60.6%). Operating vehicle might help to reduce PD-related peritonitis by preventing contamination during bag exchange. Further studies are still needed to demonstrate the protective role of the operating vehicle in preventing peritonitis.
In Vitro Microbiology Studies on a New Peritoneal Dialysis Connector
Di Bonaventura, Giovanni; Cerasoli, Paolo; Pompilio, Arianna; Arrizza, Fabio; Di Liberato, Lorenzo; Stingone, Antonio; Sirolli, Vittorio; Arduini, Arduino; Bonomini, Mario
2012-01-01
♦ Objective: We evaluated the ability of a recently developed peritoneal dialysis (PD) connector to prevent the risk of bacterial transfer to the fluid path after simulated touch and airborne contamination. ♦ Methods: Staphylococcus epidermidis ATCC1228 and Pseudomonas aeruginosa ATCC27853 strains were used. For touch contamination, 2 μL of a standardized inoculum [1×108 colony-forming units (CFU) per milliliter] were deposited on top of the pin closing the fluid path of the patient connector. For airborne contamination, the patient connector was exposed for 15 seconds to a nebulized standardized inoculum. To simulate the patient peritoneum and effluent, the patient connector was pre-attached to a 2-L bag of sterile PD solution. After contamination, the patient connector was attached to the transfer set, the pin was captured, flow control was turned to simulate “patient drain” into the empty bag, and then “patient fill” using the bag pre-attached to the connector. Finally, a new pin was recaptured. The PD solution collected in the bag pre-attached to the connector was run through a 0.20-μm filter for colony counts. ♦ Results: No infected connector transferred bacteria to the fluid path, regardless of the challenge procedure or the strain used. ♦ Conclusions: Our results show that the new PD connector may fully obviate the risk of bacterial infection, even in the presence of heavy contamination. Further studies are in progress to test our PD connector in a clinical setting. PMID:22302771
33 Years of Peritoneal Dialysis-Associated Peritonitis: A Single-Center Study in Japan.
Nakao, Masatsugu; Yamamoto, Izumi; Maruyama, Yukio; Nakashima, Akio; Matsuo, Nanae; Tanno, Yudo; Ohkido, Ichiro; Ikeda, Masato; Yamamoto, Hiroyasu; Yokoyama, Keitaro; Yokoo, Takashi
2016-02-01
Peritoneal dialysis-associated peritonitis (PD-associated peritonitis) could influence the outcome of PD patients, including technique survival. Although the use of the twin-bag system has decreased the incidence of peritonitis, the effects of biocompatible PD solutions are controversial. Additionally, since both infection-causing microorganisms and antimicrobial therapies have changed over time, the duration of treatment of peritonitis (the duration of peritonitis) seems to have changed. The study included 527 patients who received PD between January 1980 and December 2012 at a single center. We divided patients undergoing PD into three groups according to the type of PD system used, namely single-bag and conventional PD solutions (S+C group, N = 145), twin-bag and conventional PD solutions (T+C group, N = 171) and twin-bag and biocompatible PD solutions (T+B group, N = 211), and analyzed PD-associated peritonitis incidences. Incidences of PD-associated peritonitis (times per patient-months) and peritonitis-free time were 1/59.4, 1/70.6 and 1/103.1, and 52, 97, and 100 months for the S+C, T+C and T+B groups, respectively. The duration of peritonitis, has thus, become dramatically shorter in recent years. Streptococcus sp. were associated with shortest and fungi with longest durations of peritonitis. Staphylococcus sp. and Pseudomonas aeruginosa were predominant in the S+C group. The twin-bag system has made a greater contribution to reductions in PD-associated peritonitis than biocompatible PD solutions. Furthermore, changes in microorganisms, antimicrobial therapies, patient education and improved PD system devices have presumably affected the reduction in the duration of peritonitis. © 2015 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.
Ranganathan, Dwarakanathan; Naicker, Saiyuri; Wallis, Steven C; Lipman, Jeffrey; Ratanjee, Sharad K; Roberts, Jason A
2016-01-01
♦ Patients with peritoneal dialysis (PD)-associated peritonitis may be advised to store PD-bags with pre-mixed antibiotics at home, although there is a paucity of antibiotic stability studies in the commonly used icodextrin solutions. The purpose of this study was to assess the stability of various antibiotics in PD-bags when stored at different temperatures over a 14-day period. ♦ 7.5% icodextrin PD-bags were dosed with gentamicin 20 mg/L (n = 9), vancomycin 1,000 mg/L (n = 9), cefazolin 500 mg/L (n = 9) and ceftazidime 500 mg/L (n = 9) as for intermittent dosing. Combinations of gentamicin/vancomycin (n = 9), cefazolin/ceftazidime (n = 9), and cefazolin/gentamicin (n = 9) were also tested. Nine drug-free bags were used as controls. Bags were stored in triplicate at 37°C, room-temperature (25°C), and refrigeration (4°C). Antibiotic concentrations were quantified at various time intervals using validated chromatography. Storage duration was considered unstable if the concentration of the antibiotic dropped ≤ 90% of the initial value. ♦ Gentamicin was stable for 14 days at all temperatures. Vancomycin was stable for 4 days at 37°C and for 14 days at both 25°C and 4°C. The gentamicin and vancomycin combination was stable for 4 days at 37°C and for 14 days at 25°C and 4°C. Cefazolin alone was stable for 24 hours at 37°C, 7 days at 25°C, and 14 days at 4°C. Ceftazidime alone was stable for only 6 hours at 37°C, 2 days at 25°C, and 14 days at 4°C. The cefazolin and ceftazidime combination was stable for 24 hours at 37°C, 2 days at 25°C, and 14 days at 4°C. The cefazolin and gentamicin combination was stable for 1 day at 37°C, 4 days at 25°C, and 14 days at 4°C. ♦ Antibiotics premixed in icodextrin PD-bags have varying stabilities with stability generally least at 37°C and best at 4(o)C, permitting storage for 14 days when refrigerated and prewarming to body temperature prior to administration. Further research confirming the sterility of these antibiotic-containing bags is recommended. Copyright © 2016 International Society for Peritoneal Dialysis.
Prabhu, Sunil; Sullivan, Jennifer L; Betageri, Guru V
2002-01-01
The objective of our study was to compare the in vitro release kinetics of a sustained-release injectable microsphere formulation of the polypeptide drug, calcitonin (CT), to optimize the characteristics of drug release from poly-(lactide-co-glycolide) (PLGA) copolymer biodegradable microspheres. A modified solvent evaporation and double emulsion technique was used to prepare the microspheres. Release kinetic studies were carried out in silanized tubes and dialysis bags, whereby microspheres were suspended and incubated in phosphate buffered saline, sampled at fixed intervals, and analyzed for drug content using a modified Lowry protein assay procedure. An initial burst was observed whereby about 50% of the total dose of the drug was released from the microspheres within 24 hr and 75% within 3 days. This was followed by a period of slow release over a period of 3 weeks in which another 10-15% of drug was released. Drug release from the dialysis bags was more gradual, and 50% CT was released only after 4 days and 75% after 12 days of release. Scanning electron micrographs revealed spherical particles with channel-like structures and a porous surface after being suspended in an aqueous solution for 5 days. Differential scanning calorimetric studies revealed that CT was present as a mix of amorphous and crystalline forms within the microspheres. Overall, these studies demonstrated that sustained release of CT from PLGA microspheres over a 3-week period is feasible and that release of drug from dialysis bags was more predictable than from tubes.
Bender, Thorsten O; Kratochwill, Klaus; Herzog, Rebecca; Ulbrich, Andrea; Böhm, Michael; Jörres, Achim; Aufricht, Christoph
2015-10-01
Peritoneal dialysis fluids (PDFs) may induce inadequate heat-shock protein (HSP) expression and injury-related inflammation in exposed mesothelial cells. The aim of this study was to relate cellular injury to these cellular responses in mesothelial cells following repeated exposure to 3 commercial PDFs with different biocompatibility profiles. Primary cultures of human peritoneal mesothelial cells (HPMC) were exposed to a 1:2 mixture of cell culture medium and CAPD2 (single-chamber bag PDF; Fresenius, Bad Homburg, Germany), Physioneal (dual-chamber bag PDF; Baxter, Deerfield, IL, USA) or Balance (dual-chamber bag PDF, Fresenius) for up to 10 days exposure time (4 dwells). Supernatant was analyzed for LDH, IL-6, and IL-8, cells for HSP-72 expression, and protein content. PDF exposure resulted in a biphasic pattern of cell damage switching from an earlier phase with increased injury by single-chamber PDF to a delayed phase with increased susceptibility to dual-chamber PDF. Sterile inflammation was related to LDH release over time and could be reproduced by exposure to necrotic cellular material. PDF exposure resulted in low HSP-72 expression in all tested PDFs. Exposure to single-chamber as well as to dual-chamber bag PDFs induce increased vulnerability of mesothelial cells to repeated exposure of the same solution. These effects were delayed with dual-chamber PDFs. Injury-induced inflammation and impaired HSP expression upon PDF exposure might initiate a vicious cycle with progredient mesothelial cell damage upon repeated PDF exposure. Certainly, interventional studies and translation of these results into the in vivo system is needed.
[Peritoneal dialysis at a regional hospital in Norway].
Paulsen, Dag; Solbakken, Kjell; Valset, Torstein
2011-08-23
In 2006, an expert group appointed by the Norwegian Social and Health Directory recommended that the proportion of patients on peritoneal dialysis should increase from 15 % to about 30 %. We wanted to investigate if treatment in our hospital was in compliance with that recommendation. The patient material consisted of the total number of patients on dialysis and anonymised data collected for patients treated with peritoneal dialysis at Innlandet Hospital Trust, Lillehammer in the period 1.01.2004-31.12.2008. For patients in peritoneal dialysis we assessed patient dynamics, length of hospital stay, incidence of peritonitis, need for assistance and organisation of peritoneal dialysis activity. Dialysis treatment was given to 176 patients, 62 (35 %) of whom were treated by peritoneal dialysis for at least 30 days (mean treatment time 16.2 months). 17 patients were switched from hemodialysis to peritoneal dialysis and nine patients from peritoneal dialysis to hemodialysis. Patients older than 70 years stayed in hospital 6 days longer than those younger than 70 years. 27 (44 %) of the patients acquired peritonitis in the study period and 18 (29 %) patients needed help to exchange the dialysis bag. The proportion of patients treated with peritoneal dialysis in our hospital has reached the recommended level. The reason may be that all eligible patients are offered peritoneal dialysis and that the treatment chain is well organised.
2010-09-01
Regulatory Council LRL Laboratory reporting level LDPE Low-density polyethylene MDL Minimum detection limit MNA Monitored natural attenuation...consists of a tubular-shaped bag made of flexible low-density polyethylene ( LDPE ) (Vroblesky, 2001a, 2001b). The LDPE tube is heat-sealed on one end...be constructed from small- diameter LDPE tubing that fits into small-diameter wells. These polyethylene diffusion bag (PDB) samplers have been
2011-10-01
Regulatory Council LDPE low-density polyethylene MDL minimum detection limit NAVFAC ESC Naval Facilities Engineering Command Engineering Service...membrane sampler design consists of a tubular-shaped bag made of flexible low-density polyethylene ( LDPE ) (Vroblesky, 2001a, 2001b). The LDPE tube is...requirements, and can be constructed from small-diameter LDPE tubing that fits into small- 4 diameter wells. These polyethylene diffusion bag
Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.
2003-01-01
During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.
Distribution of di(2-ethylhexyl) phthalate and products in blood and blood components.
Rock, G; Labow, R S; Tocchi, M
1986-01-01
In order to impart flexibility, plastic medical devices incorporate liquid plasticizers into their structure. Data from several laboratories, including ours, have shown that these compounds leach from blood bags and tubing during collection of blood, storage of various blood components and during kidney dialysis and cell and plasma apheresis procedures. After the plasticizer di(2-ethylhexyl) phthalate leaches from poly(vinyl chloride) blood packs, it is converted by a plasma enzyme to a more toxic metabolite, mono(2-ethylhexyl) phthalate. Blood fractionation products from outdated plasma contain mono(2-ethylhexyl) phthalate, the highest level being found in normal serum albumin. Recently, we have reported that di(2-ethylhexyl) phthalate actually binds to the red blood cell membrane and reduces its osmotic fragility. Current methods of red cells storage, which permit utilization up to 35 days after collection, are not possible without this membrane stabilization. Platelets are now stored for 5 days in the Fenwal PL 732 polyolefin bag. Although stated to be essentially free of liquid plasticizers, a significant level of leaching from this bag into the extracts of stored platelet concentrates was observed. PMID:3709456
Egan, L J; Sandborn, W J; Mays, D C; Tremaine, W J; Lipsky, J J
1998-07-01
It is useful to measure the luminal concentration of drugs which act in the gut. Dialysis of the rectum has not previously been used or validated for this purpose. To determine the precision of rectal dialysis for measuring rectal drug concentrations. To establish the duration of dialysis required to approach equilibrium, the rate of methotrexate diffusion into dialysis bags was first determined in vitro. The precision of rectal dialysis for sampling the methotrexate concentration of colonic lumen extracellular fluid was determined in seven subjects who underwent two consecutive dialysis procedures. Subjects treated with subcutaneous methotrexate for refractory inflammatory bowel disease were studied. Methotrexate crossed the dialysis membrane by a first-order process, and after a 2 h in vitro dialysis, equilibration was 74 +/- 2% (mean +/- s.d.) complete. Rectal dialysis was well tolerated by all subjects. The mean +/- s.e. methotrexate concentration of 3.6 +/- 1.1 nmol/L in the first dialysate was not significantly different from 3.6 +/- 0.9 nmol/L in the second dialysate. P = 0.99 (paired two-tailed t-test). Similar precision was obtained for an endogenous molecule, potassium, secreted by the rectal mucosa. Dialysis of the rectum is a well tolerated and precise technique for sampling the colonic lumen extracellular fluid for quantitative analyses of exogenous and endogenous substances.
Single Daily Icodextrin Exchange as Initial and Solitary Therapy.
Agar, Baris U; Sloand, James A
2018-01-01
Incremental dialysis utilizes gradually increasing dialysis doses in response to declines in residual kidney function, and it is the preferred renal replacement therapy for patients who have just transitioned to end-stage renal disease (ESRD). Incremental peritoneal dialysis (PD) may impose fewer restrictions on patients' lifestyle, help attenuate lifetime peritoneal and systemic exposure to glucose and its degradation products, and minimize connections that could compromise the sterile fluid path. In this study, we utilized a 3-pore kinetic model to assess fluid and solute removal during single daily icodextrin treatments for patients with varying glomerular filtration rates (GFR). Single icodextrin exchanges of 8 to 16 hours using 2- and 2.5-L bag volumes were simulated for different patient transport types (i.e., high to low) to predict daily peritoneal ultrafiltration (UF), daily peritoneal sodium removal, and weekly total (peritoneal + residual kidney) Kt/V (Kt/V Total ) for patients with residual renal GFRs ranging from 0 to 15 mL/min/1.73 m 2 . Daily peritoneal UF varied from 359 to 607 mL, and daily peritoneal Na removal varied from 52 to 87 mEq depending on length of icodextrin exchange and bag volume. Both were effectively independent of patient transport type. All but very large patients (total body water [TBW] > 60 L) were predicted to achieve adequate dialysis (Kt/V Total ≥ 1.7) with a GFR of 10 mL/min/1.73 m 2 , and small patients (TBW: 30 L) were predicted to achieve adequate dialysis with a GFR of 6 mL/min/1.73 m 2 . A single daily icodextrin exchange can be tailored to augment urea, UF, and Na removal in patients with sufficient residual kidney function (RKF). A solitary icodextrin exchange may therefore be reasonable initial therapy for some incident ESRD patients. Copyright © 2018 International Society for Peritoneal Dialysis.
Wieczorowska-Tobis, Katarzyna; Brelinska, Renata; Witowski, Janusz; Passlick-Deetjen, Jutta; Schaub, Thomas P; Schilling, Holger; Breborowicz, Andrzej
2004-01-01
Acidic pH and the presence of glucose degradation products (GDP) are believed to compromise the biocompatibility of peritoneal dialysis fluids (PDF). The present study examines the effects of long-term exposure to GDP and low pH by comparing conventional PDF and a new, neutral pH, low GDP solution. All experiments were performed using a chronic infusion model of dialysis in nonuremic rats. The animals were treated for 6 weeks with 2 daily injections of 4.25% glucose-containing PDF. The following PDF were tested: CAPD3 (single-chamber bag, low pH, high GDP), CAPD3 pH 7.4 (single-chamber bag, neutral pH, high GDP), CAPD3-Balance (double-chamber bag, neutral pH, low GDP). All test solutions were obtained from Fresenius Medical Care, Bad Homburg, Germany. After 6 weeks of exposure, peritoneal permeability to water, urea, creatinine, glucose, and sodium, assessed by peritoneal equilibration test, was similar in all groups. However, compared to other PDF, dialysis with CAPD3-Balance was associated with reduced concentrations of protein and hyaluronan in the dialysate, decreased peritoneal eosinophilia, and reduced dialysate levels of chemokines CCL2/MCP-1 and CCL5/RANTES. Morphologic changes in the peritoneal membrane of CAPD3-Balance-treated animals were much less pronounced and included reduced vascular density, preservation of the mesothelial monolayer and intercellular junction, and no reduplication of the submesothelial basement membrane. A new generation of PDF with physiologic pH and low GDP level produce less irritation to the peritoneal membrane and better preserve its structural integrity. This effect seems to be related predominantly to minimized GDP concentrations.
Gaab, Manuela; Bellemin-Laponnaz, Stéphane; Gade, Lutz H
2009-01-01
Bis- and trisoxazolines (BOX and trisox), containing a linker unit in the ligand backbone that allows their covalent attachment to carbosilane dendrimers, have been employed as polyfunctional ligands for recyclable Cu(II) Lewis acid catalysts that were immobilised in a membrane bag. The oxazolines contained an alkynyl unit attached to their backbone that was deprotonated with LDA or BuLi and then reacted with the chlorosilyl termini of zeroth-, first- and second-generation carbosilane dendrimers in the presence of TlPF(6). The functionalised dendritic systems were subsequently separated from excess ligand by way of dialysis. The general catalytic potential of these systems was assessed by studying two benchmark reactions, the alpha-hydrazination of a beta-keto ester as well as the Henry reaction of 2-nitrobenzaldehyde with nitromethane. For both reactions the bisoxazoline-based catalysts displayed superior selectivity and, in particular, catalyst activity. The latter was interpreted as being due to the hindered decoordination of the third oxazoline unit, the key step in the generation of the active catalyst, in the immobilised trisox-copper complexes. Solutions of the second-generation dendrimer catalysts were placed in membrane bags, fabricated from commercially available dialysis membranes, with the purpose of catalyst recycling based on dialysis. Overall, the supported BOX catalyst gave good and highly reproducible results throughout the study, whereas the performance of the trisox dendrimer system decreased monotonically. The reason for the different behaviour is the markedly lower activity of trisox-based catalysts relative to those based on the BOX ligand. This necessitated an increased reaction time for each cycle of the trisox derivatives, resulting in higher levels of catalyst leaching, which was attributed to a modification of the structure of the membrane by its exposure to the solvent trifluoroethanol at 40 degrees C.
NASA Astrophysics Data System (ADS)
Guo, Lanyu; Liu, Liyun; Zhuo, Mingpeng; Fu, Shulei; Xu, Yunpeng; Zhou, Wenwei; Shi, Ce; Ye, Bin; Li, Yongxiu; Chen, Weifan
2018-07-01
In this work, presented is a novel and facile strategy to enhance Pb(II) adsorption capacity of graphene oxide (GO) hydrosols via the modified Hummers' method, using the smaller-sized natural flake graphite as starting materials. The as-prepared micron GO (MGO) and submicron GO (SMGO) hydrosols were sealed in dialysis bags for adsorptive separation of Pb(II) from water to avoid secondary pollution. The effects of pH and contact duration on Pb(II) adsorption on MGO and SMGO as well as their thermodynamics and kinetics were investigated comparatively. Their performances for recycling and regeneration were also evaluated. The results indicated that SMGO exhibited an enhanced maximum sorption capacity for Pb(II) up to 1162.60 mg·g-1 higher than MGO by 25.75% and achieved adsorption equilibrium faster, which can be attributed to the fact that SMGO has more oxygen-containing functional groups on the sheet basal planes and especially at the sheet edges than SMGO. The adsorption of Pb(II) on MGO and SMGO was a spontaneous and endothermic process and well fitted the pseudo-second-order kinetics and the Langmuir sorption model. Significantly, MGO and SMGO nanosheets still kept the high sorption capacities of 514.26 mg·g-1 and 700.35 mg·g-1 after the 5 cycles, respectively, promising of enormous potential applications.
2007-08-30
ITRC Interstate Technology Regulatory Council LRL Laboratory reporting level LDPE Low-density polyethylene MDL Minimum detection limit MNA...diameter of the well. Another diffusion membrane sampler design consists of a tubular-shaped bag made of flexible low-density polyethylene ( LDPE ...
Pancreatitis: an important cause of abdominal symptoms in patients on peritoneal dialysis.
Caruana, R J; Wolfman, N T; Karstaedt, N; Wilson, D J
1986-02-01
In an eight-month period, four patients in our peritoneal dialysis program developed acute pancreatitis, an incidence significantly higher than that in our hemodialysis program. Diagnosis was difficult since the symptoms of pancreatitis were similar to those of peritoneal dialysis-associated peritonitis. Further difficulties in diagnosis were due to unreliability of serum amylase levels and "routine" ultrasound examinations in suggesting the presence of pancreatitis. Computerized tomography performed in three patients showed enlarged, edematous pancreata with large extrapancreatic fluid collections in all cases. Two patients died, one directly due to complications of pancreatitis. One patient was changed to hemodialysis and showed clinical and radiologic resolution of his pancreatitis. One patient remains on peritoneal dialysis but has now had four attacks of acute pancreatitis. No patient had classic risk factors for development of pancreatitis. Review of patient histories showed no common historical factors except for renal failure itself, peritoneal dialysis, peritonitis, catheter surgery, and hypoproteinemia. It is possible that metabolic abnormalities related to absorption of glucose and buffer from dialysate or absorption of a toxic substance present in dialysate, bags, or tubing can cause pancreatitis in patients on peritoneal dialysis. We feel that a diagnosis of pancreatitis should be considered when peritoneal dialysis patients present with abdominal pain, particularly if peritoneal fluid cultures are negative or if patients with positive cultures do not have prompt resolution of symptoms with appropriate antibiotic therapy.
Scottish Schools Science Equipment Research Centre, Bulletin No. 56, June 1972.
ERIC Educational Resources Information Center
1972
A model demonstrating the relationship between the structure of blood vessels and the flow of blood is described and illustrated in the biology section of the newsletter. The apparatus also contains a functional (but not structural) model of the heart. Suggestions for the preparation of a relatively permanent dialysis bag from visking tubing are…
Ozminkowski, R J; Hassol, A; Firkusny, I; Noether, M; Miles, M A; Newmann, J; Sharda, C; Guterman, S; Schmitz, R
1995-04-01
The Medicare program's base payment rate for outpatient dialysis services has never been adjusted for the effects of inflation, productivity changes, or scientific and technological advancement on the costs of treating patients with end-stage renal disease. In recognition of this, Congress asked the Prospective Payment Assessment Commission to annually recommend an adjustment to Medicare's base payment rate to dialysis facilities. One component of this adjustment addresses the cost-increasing effects of technological change--the scientific and technological advances (S&TA) component. The S&TA component is intended to encourage dialysis facilities to adopt technologies that, when applied appropriately, enhance the quality of patient care, even though they may also increase costs. We found the appropriate increase to the composite payment rate for Medicare outpatient dialysis services in fiscal year 1995 to vary from 0.18% to 2.18%. These estimates depend on whether one accounts for the lack of previous adjustments to the composite rate. Mathematically, the S&TA adjustment also depends on whether one considers the likelihood of missing some dialysis sessions because of illness or hospitalization. The S&TA estimates also allow for differences in the incremental costs of technological change that are based on the varying advice of experts in the dialysis industry. The major contributors to the cost of technological change in dialysis services are the use of twin-bag disconnect peritoneal dialysis systems, automated peritoneal dialysis cyclers, and the new generation of hemodialysis machines currently on the market. Factors beyond the control of dialysis facility personnel that influence the cost of patient care should be considered when payment rates are set, and those rates should be updated as market conditions change. The S&TA adjustment is one example of how the composite rate payment system for outpatient dialysis services can be modified to provide appropriate incentives for producing high-quality care efficiently.
Su, Chun-Yan; Wang, Tao; Lu, Xin-Hong; Ma, Sha; Tang, Wen; Wang, Pei-Yu
2017-02-01
Due to limited economic conditions, we tried to provide "fitted" dialysis doses instead of the doses recommended by the international guidelines to the individual patients. In the present cross-sectional study, we studied the dialysis adequacy and nutritional status of 5 peritoneal dialysis patients who had a low dialysis dose (2 bags, 4,000 mL/day). The 3-day dietary records were reviewed to calculate patients' energy, protein, and nitrogen intake (NI). The nitrogen removal (NR) from urine and dialysate was measured by Kjeldahl technique. Fecal nitrogen was estimated as 0.0155 g/kg/day. Subjective global nutritional assessment was used to evaluate the nutritional status. Among the 5 patients, 1 male and 4 female, mean age was 59 (42 - 81) years, dialysis duration 43 (33 - 74) months, body weight 51.05 ± 2.53 kg. The mean dietary protein intake was 0.66 g/kg/day, total weekly Kt/v was 1.25 (residual kidney Kt/v was 0.09), and total daily fluid removal was 699 mL. However, they achieved lower-level neutral nitrogen balance (NI 5.26 ± 0.93 g/day vs. NR 5.33 ± 0.81 g/day, N balance -0.07 ± 0.60 g/day). All of them maintained good nutritional status (SGA "A") without symptoms of nitrogen retention (serum urea 22 ± 4.18 mmol/L). Lower dialysis dose with lower daily protein intake can achieve a lower-level nitrogen balance and does not lead to malnutrition. It may be an effective approach to solve the dialysis problem for the economically week population in China, especially for people with a smaller body size with lower transport membrane. .
Zeng, Yanfeng; Fan, Licheng; Lu, Peirong
2017-04-01
Objective To observe the treatment effects of chop hook-assisted phacoemulsification surgery in patients with crystalline lens dislocation. Methods Thirty-seven eyes with cataracts and crystalline lens dislocations underwent cataract surgery. An L-shaped chop hook was introduced into the anterior chamber, and the tip was pushed or pulled to the centre of the anterior capsular edge of the zonular dialysis during the cataract operation. Postoperative follow-up was conducted for ≥ 1 month. Results All patients' postoperative visual abilities improved except one patient with glaucoma. One patient who underwent -5D intraocular lens implantation exhibited vision of 1/50. Visual acuity was less than 6/20 in 6 eyes, 6/20 to 10/20 in 7 eyes, and greater than 10/20 in 22 eyes. Conclusions L-shaped chop hooks can be used to push or pull the anterior capsular edge of the zonular dialysis for protection and avoidance of further zonular damage. This strategy provides satisfactory effects and reduces use of additional instruments.
Janas, Christine; Mast, Marc-Phillip; Kirsamer, Li; Angioni, Carlo; Gao, Fiona; Mäntele, Werner; Dressman, Jennifer; Wacker, Matthias G
2017-06-01
The dispersion releaser (DR) is a dialysis-based setup for the analysis of the drug release from nanosized drug carriers. It is mounted into dissolution apparatus2 of the United States Pharmacopoeia. The present study evaluated the DR technique investigating the drug release of the model compound flurbiprofen from drug solution and from nanoformulations composed of the drug and the polymer materials poly (lactic acid), poly (lactic-co-glycolic acid) or Eudragit®RSPO. The drug loaded nanocarriers ranged in size between 185.9 and 273.6nm and were characterized by a monomodal size distribution (PDI<0.1). The membrane permeability constants of flurbiprofen were calculated and mathematical modeling was applied to obtain the normalized drug release profiles. For comparing the sensitivities of the DR and the dialysis bag technique, the differences in the membrane permeation rates were calculated. Finally, different formulation designs of flurbiprofen were sensitively discriminated using the DR technology. The mechanism of drug release from the nanosized carriers was analyzed by applying two mathematical models described previously, the reciprocal powered time model and the three parameter model. Copyright © 2017 Elsevier B.V. All rights reserved.
2010-04-01
LDPE low-density polyethylene LF low-flow purging LRL laboratory reporting level MDL minimum detection limit MNA monitored natural attenuation...shaped bag made of flexible low-density polyethylene ( LDPE ) (Vroblesky, 2001a, 2001b). The LDPE tube is heat-sealed on one end, filled with high...from small- diameter LDPE tubing that fits into small-diameter wells. These PDB samplers have been shown to be useful only for collection of VOCs
Sun, Jia-an; Kong, De-zhi; Zhen, Ya-qin; Li, Qing; Zhang, Wei; Zhang, Jiang-hua; Yin, Zhi-wei; Ren, Lei-ming
2013-01-01
Aim: (±)Doxazosin is a long-lasting inhibitor of α1-adrenoceptors that is widely used to treat benign prostatic hyperplasia and lower urinary tract symptoms. In this study we investigated the stereoselective binding of doxazosin enantiomers to the plasma proteins of rats, dogs and humans in vitro. Methods: Human, dog and rat plasma were prepared. Equilibrium dialysis was used to determine the plasma protein binding of each enantiomer in vitro. Chiral HPLC with fluorescence detection was used to measure the drug concentrations on each side of the dialysis membrane bag. Results: Both the enantiomers were highly bound to the plasma proteins of rats, dogs and humans [(−)doxazosin: 89.4%–94.3%; (+)doxazosin: 90.9%–95.4%]. (+)Doxazosin exhibited significantly higher protein binding capacities than (−)doxazosin in all the three species, and the difference in the bound concentration (Cb) between the two enantiomers was enhanced as their concentrations were increased. Although the percentage of the plasma protein binding in the dog plasma was significantly lower than that in the human plasma at 400 and 800 ng/mL, the corrected percentage of plasma protein binding was dog>human>rat. Conclusion: (−)Doxazosin and (+)doxazosin show stereoselective plasma protein binding with a significant species difference among rats, dogs and humans. PMID:24241343
2010-09-30
Inductively coupled plasma – mass spectrometry ITRC Interstate Technology Regulatory Council LRL Laboratory reporting level LDPE Low-density polyethylene...diameter of the well. Another diffusion membrane sampler design consists of a tubular-shaped bag made of flexible low-density polyethylene ( LDPE ...Vroblesky, 2001a, 2001b). The LDPE tube is heat-sealed on one end, filled with high-purity water, heat-sealed at the top, and then suspended in a well to
de Andrade, Diego Fontana; Zuglianello, Carine; Pohlmann, Adriana Raffin; Guterres, Silvia Stanisçuaski; Beck, Ruy Carlos Ruver
2015-12-01
The in vitro assessment of drug release from polymeric nanocapsules suspensions is one of the most studied parameters in the development of drug-loaded nanoparticles. Nevertheless, official methods for the evaluation of drug release from submicrometric carriers are not available. In this work, a new approach to assess the in vitro drug release profile from drug-loaded lipid-core nanocapsules (LNC) was proposed. A continuous-flow system (open system) was designed to evaluate the in vitro drug release profiles from different LNC formulations containing prednisolone or clobetasol propionate (LNC-CP) as drug model (LNC-PD) using a homemade apparatus. The release medium was constantly renewed throughout the experiment. A dialysis bag containing 5 mL of formulation (0.5 mg mL(-1)) was maintained inside the apparatus, under magnetic stirring and controlled temperature (37°C). In parallel, studies based on the conventional dialysis sac technique (closed system) were performed. It was possible to discriminate the in vitro drug release profile of different formulations using the open system. The proposed strategy improved the sink condition, by constantly renewing the release medium, thus maintaining the drug concentration farther from the saturated concentration in the release medium. Moreover, problems due to sampling errors can be easily overcome using this semi-automated system, since the collection is done automatically without interference from the analyst. The system proposed in this paper brings important methodological and analytical advantages, becoming a promising prototype semi-automated apparatus for performing in vitro drug release studies from drug-loaded lipid-core nanocapsules and other related nanoparticle drug delivery systems.
NASA Astrophysics Data System (ADS)
Tominaga, Yoko; Kadota, Kazunori; Shimosaka, Atsuko; Yoshida, Mikio; Oshima, Kotaro; Shirakawa, Yoshiyuki
2018-05-01
The preparation of the titanium dioxide hollow particles encapsulating L-ascorbic acid via sol-gel process using inkjet nozzle has been performed, and the sustained release and the effect protecting against degradation of L-ascorbic acid in the particles were investigated. The morphology of titanium dioxide particles was evaluated by scanning electron microscopy (SEM) and energy dispersive X-ray spectrometry (EDS). The sustained release and the effect protecting against degradation of L-ascorbic acid were estimated by dialysis bag method in phosphate buffer saline (PBS) (pH = 7.4) as release media. The prepared titanium dioxide particles exhibited spherical porous structures. The particle size distribution of the titanium dioxide particles was uniform. The hollow titanium dioxide particles encapsulating L-ascorbic acid showed the sustained release. It was also found that the degradation of L-ascorbic acid could be inhibited by encapsulating L-ascorbic acid in the titanium dioxide hollow particles.
Developments in Methods for Measuring the Intestinal Absorption of Nanoparticle-Bound Drugs
Liu, Wei; Pan, Hao; Zhang, Caiyun; Zhao, Liling; Zhao, Ruixia; Zhu, Yongtao; Pan, Weisan
2016-01-01
With the rapid development of nanotechnology, novel drug delivery systems comprising orally administered nanoparticles (NPs) have been paid increasing attention in recent years. The bioavailability of orally administered drugs has significant influence on drug efficacy and therapeutic dosage, and it is therefore imperative that the intestinal absorption of oral NPs be investigated. This review examines the various literature on the oral absorption of polymeric NPs, and provides an overview of the intestinal absorption models that have been developed for the study of oral nanoparticles. Three major categories of models including a total of eight measurement methods are described in detail (in vitro: dialysis bag, rat gut sac, Ussing chamber, cell culture model; in situ: intestinal perfusion, intestinal loops, intestinal vascular cannulation; in vivo: the blood/urine drug concentration method), and the advantages and disadvantages of each method are contrasted and elucidated. In general, in vitro and in situ methods are relatively convenient but lack accuracy, while the in vivo method is troublesome but can provide a true reflection of drug absorption in vivo. This review summarizes the development of intestinal absorption experiments in recent years and provides a reference for the systematic study of the intestinal absorption of nanoparticle-bound drugs. PMID:27455239
Jugnia, Louis-B; Sime-Ngando, Télesphore; Gilbert, Daniel
2006-10-01
The growth rate and losses of bacterioplankton in the epilimnion of an oligo-mesotrophic reservoir were simultaneously estimated using three different methods for each process. Bacterial production was determined by means of the tritiated thymidine incorporation method, the dialysis bag method and the dilution method, while bacterial mortality was assessed with the dilution method, the disappearance of thymidine-labeled natural cells and ingestion of fluorescent bacterial tracers by heterotrophic flagellates. The different methods used to estimate bacterial growth rates yielded similar results. On the other hand, the mortality rates obtained with the dilution method were significantly lower than those obtained with the use of thymidine-labeled natural cells. The bacterial ingestion rate by flagellates accounted on average for 39% of total bacterial mortality estimated by the dilution method, but this value fell to 5% when the total mortality was measured by the thymidine-labeling method. Bacterial abundance and production varied in opposite phase to flagellate abundance and the various bacterial mortality rates. All this points to the critical importance of methodological aspects in the elaboration of quantitative models of matter and energy flows over the time through microbial trophic networks in aquatic systems, and highlights the role of bacterioplankton as a source of carbon for higher trophic levels in the studied system.
Costs of home assistance for peritoneal dialysis: results of a European survey.
Dratwa, M
2008-04-01
Assisted peritoneal dialysis (aPD) was 'invented' in France in 1977 and was immediately very well reimbursed. This has since helped to maintain a high French peritoneal dialysis (PD) penetration rate among elderly dependent patients who might enjoy a better quality of life by remaining in their own environment. The aim of this study was to investigate the present status of aPD funding in European countries through a questionnaire sent in 2006 to health authorities and commercial PD providers asking about reimbursement modalities (in euro ([euro]) per patient per year) for nurse aPD. Specific funding for aPD only exists in Belgium, Denmark, France, Switzerland, and one region of Spain (Canary Islands). Germany and the United Kingdom are testing pilot schemes. Compared to France, all other countries exhibit significant differences in reimbursement for similar services (performing bag exchanges or disconnections from/to a cycler, exit site care, monitoring weight as well as blood pressure and ultrafiltration, and also including transportation costs) both for continuous ambulatory peritoneal dialysis (CAPD) (23 400 vs 7280 \\[euro] per patient per year in Spain) and automated peritoneal dialysis (APD) (18 200 vs 5356 euro per patient per year in Belgium); these differences are difficult to understand and might reflect disparities in cost of living, national health-care budget, and/or mean nurses' salaries. Also, there is no correlation between these rates and the reimbursement for PD therapy itself. Only France and Belgium differentiate assisted CAPD and APD, but these differences do not reflect the time really spent at the patient's home. It is concluded that high reimbursement rates for assistance add significant extra cost to PD, but allow granting many dependent patients all the advantages of home therapy, instead of treating them with in-center hemodialysis which in any case still remains more expensive for our societies.
Peritoneal dialysis--experiences.
Mirković, Tatjana Durdević
2010-01-01
Peritoneal dialysis is the method of treatment of terminal-stage chronic kidney failure. Nowadays, this method is complementary to haemodialysis. It is based on the principles of the diffusion of solutes and ultrafiltration of fluids across the peritoneal membrane, which acts as a filter. The dialysate is introduced into the peritoneum via the previously positioned peritoneal catheter. The peritoneal dialysis is carried out on daily basis, at home by the patient, and the "exchange" is repeated 4-5 times during the 24 hours. The first steps in peritoneal dialysis at the Department for Haemodialysis of the Clinical Centre of Vojvodina date back to 1973. Until 1992, the patients were subjected to this program only sporadically. Since 1998 the peritoneal dialysis method has been performed at the Clinic for Nephrology and Clinical Immunology. In the period 1998-2008 ninety nine peritoneal catheters were placed. Chronic glomerulonephritis, nephroangiosclerosis and diabetes were identified as the most common causes of chronic renal failure. Two methods of catheter placement were applied: the standard open surgery method (majority of patients) and laparoscopy. Most of the patients were subjected to continuous ambulatory peritoneal dialysis, whereas four patients received automatic dialysis. Transplantation was performed in 10 patients, i.e. cadaveric transplantation and living-related donor transplantation, each in 5 patients. Peritoneal dialysis was available as a service outside our institution as well. A ten-year experience in peritoneal dialysis gained at our Centre has proved the advantages and qualities of this method, strongly supporting its wider application in the treatment of terminal-stage chronic kidney failure.
Grabowy, R S; Kelley, R; Richter, S G; Bousquet, G G; Carr, K L
1998-01-01
Microbiological data have been collected on the performance of a new method of isolating and disinfecting the intraluminal path at the connect/disconnect site of a peritoneal dialysis (PD)-exchange pathway. High-temperature moist-heat (HTMH) disinfection is accomplished by a new device that uses microwave energy to heat the solution contained in the pressure-tight inner lumen of PD connector pairs between the transfer-set connector-clamp and the bag-connector break-away seal. An 85 degrees C (S.D. = 2.4 degrees C, n = 10) rise in solution temperature is seen in 12 seconds, thus yielding temperatures under pressure well over 100 degrees C with starting temperatures of 25 degrees C. Connector pairs were prepared by inoculation of a solution suspension containing at least 10(6) colony-forming units (CFU) of a test micro-organism. Approximately 0.4 mL of solution was contained within the mated connector pair. Using standard D-value determination methods, data were obtained for surviving organisms versus five exposure times and a positive control to obtain a population reduction curve. Four micro-organisms (S. epidermidis, P. aeruginosa, C. albicans, and A. niger) recognized to be among the most prevalent or problematic in causing peritonitis were tested. After microwave heating, the treated solution was aseptically withdrawn from the connector pair using a needle and syringe, plated in growth media, and incubated. Population counts of CFUs after incubation were used to establish survival curves. Results showed a tenfold population reduction in less than 3 seconds for all organisms tested. A 30-second cycle time safely achieves a > 10(8) population-reduction for bacteria and yeast organisms, and a > 10(7) population reduction for fungi. One potential benefit of using this new intraluminal disinfection method is that it may help reduce peritonitis resulting from the even more problematic pathogens such as the gram-negative bacteria and fungal organisms.
A Rapid Dialysis Method for Analysis of Artificial Sweeteners in Foods (2nd Report).
Tahara, Shoichi; Yamamoto, Sumiyo; Yamajima, Yukiko; Miyakawa, Hiroyuki; Uematsu, Yoko; Monma, Kimio
2017-01-01
Following the previous report, a rapid dialysis method was developed for the extraction and purification of four artificial sweeteners, namely, sodium saccharide (Sa), acesulfame potassium (AK), aspartame (APM), and dulcin (Du), which are present in various foods. The method was evaluated by the addition of 0.02 g/kg of these sweeteners to a cookie sample, in the same manner as in the previous report. Revisions from the previous method were: reduction of the total dialysis volume from 200 to 100 mL, change of tube length from 55 to 50 cm, change of dialysate from 0.01 mol/L hydrochloric aqueous solution containing 10% sodium chloride to 30% methanol solution, and change of dialysis conditions from ambient temperature with occasional shaking to 50℃ with shaking at 160 rpm. As a result of these revisions, the recovery reached 99.3-103.8% with one hour dialysis. The obtained recovery yields were comparable to the recovery yields in the previous method with four hour dialysis.
Partitioning of monomethylmercury between freshwater algae and water.
Miles, C J; Moye, H A; Phlips, E J; Sargent, B
2001-11-01
Phytoplankton-water monomethylmercury (MeHg) partition constants (KpI) have been determined in the laboratory for two green algae Selenastrum capricornutum and Cosmarium botrytis, the blue-green algae Schizothrix calcicola, and the diatom Thallasiosira spp., algal species that are commonly found in natural surface waters. Two methods were used to determine KpI, the Freundlich isotherm method and the flow-through/dialysis bag method. Both methods yielded KpI values of about 10(6.6) for S. capricornutum and were not significantly different. The KpI for the four algae studied were similar except for Schizothrix, which was significantly lower than S. capricornutum. The KpI for MeHg and S. capricornutum (exponential growth) was not significantly different in systems with predominantly MeHgOH or MeHgCl species. This is consistent with other studies that show metal speciation controls uptake kinetics, but the reactivity with intracellular components controls steady-state concentrations. Partitioning constants determined with exponential and stationary phase S. capricornutum cells at the same conditions were not significantly different, while the partitioning constant for exponential phase, phosphorus-limited cells was significantly lower, suggesting that P-limitation alters the ecophysiology of S. capricornutum sufficiently to impact partitioning, which may then ultimately affect mercury levels in higher trophic species.
Multiple-Instance Regression with Structured Data
NASA Technical Reports Server (NTRS)
Wagstaff, Kiri L.; Lane, Terran; Roper, Alex
2008-01-01
We present a multiple-instance regression algorithm that models internal bag structure to identify the items most relevant to the bag labels. Multiple-instance regression (MIR) operates on a set of bags with real-valued labels, each containing a set of unlabeled items, in which the relevance of each item to its bag label is unknown. The goal is to predict the labels of new bags from their contents. Unlike previous MIR methods, MI-ClusterRegress can operate on bags that are structured in that they contain items drawn from a number of distinct (but unknown) distributions. MI-ClusterRegress simultaneously learns a model of the bag's internal structure, the relevance of each item, and a regression model that accurately predicts labels for new bags. We evaluated this approach on the challenging MIR problem of crop yield prediction from remote sensing data. MI-ClusterRegress provided predictions that were more accurate than those obtained with non-multiple-instance approaches or MIR methods that do not model the bag structure.
Yang, Zhen; Kappler, Andreas; Jiang, Jie
2016-11-15
Humic substances (HS) are redox-active organic compounds with a broad spectrum of molecular sizes and reducing capacities, that is, number of electrons donated or accepted. However, it is unknown which role the distribution of redox-active functional groups in different molecule sizes plays for HS redox reactions in varying pore sizes microenvironments. We used dialysis experiments to separate bulk humic acids (HA) into low molecular weight fractions (LMWF) and retentate, for example, the remaining HA in the dialysis bag. LMWF accounted for only 2% of the total organic carbon content of the HA. However, their reducing capacities per gram of carbon were up to 33 times greater than either those of the bulk HA or the retentate. For a structural/mechanistic understanding of the high reducing capacity of the LMWF, we used fluorescence spectroscopy. We found that the LWMF showed significant fluorescence intensities for quinone-like functional groups, as indicated by the quinoid π-π* transition, that are probably responsible for the high reducing capacities. Therefore, the small-sized HS fraction can play a major role for redox transformation of metals or pollutants trapped in soil micropores (<2.5 nm diameter).
Industrial filter bags cleaned by high-frequency vibration: A concept
NASA Technical Reports Server (NTRS)
Kooy, A. V.
1973-01-01
System holds filter bag around fine-mesh metal screen and vibrates screen at its resonant frequency. This removes deposited byproducts and protects bag fibers from damaging forces. Because filter bags represent 20 to 40% of any industrial filtering investment, this method of extending bag life should be of interest to those responsible for plant maintenance.
Neighborhood Socioeconomic Status and Barriers to Peritoneal Dialysis: A Mixed Methods Study
Perzynski, Adam T.; Austin, Peter C.; Wu, C. Fangyun; Lawless, Mary Ellen; Paterson, J. Michael; Quinn, Rob R.; Sehgal, Ashwini R.; Oliver, Matthew James
2013-01-01
Summary Background and objectives The objective of this study was to evaluate the association between neighborhood socioeconomic status and barriers to peritoneal dialysis eligibility and choice. Design, setting, participants, & measurements This study was a mixed methods parallel design study using quantitative and qualitative data from a prospective clinical database of ESRD patients. The eligibility and choice cohorts were assembled from consecutive incident chronic dialysis patients entering one of five renal programs in the province of Ontario, Canada, between January 1, 2004 and December 31, 2010. Socioeconomic status was measured as median household income and percentage of residents with at least a high school education using Statistics Canada dissemination area-level data. Multivariable models described the relationship between socioeconomic status and likelihood of peritoneal dialysis eligibility and choice. Barriers to peritoneal dialysis eligibility and choice were classified into qualitative categories using the thematic constant comparative approach. Results The peritoneal dialysis eligibility and choice cohorts had 1314 and 857 patients, respectively; 65% of patients were deemed eligible for peritoneal dialysis, and 46% of eligible patients chose peritoneal dialysis. Socioeconomic status was not a significant predictor of peritoneal dialysis eligibility or choice in this study. Qualitative analyses identified 16 barriers to peritoneal dialysis choice. Patients in lower- versus higher-income Statistics Canada dissemination areas cited built environment or space barriers to peritoneal dialysis (4.6% versus 2.7%) and family or social support barriers (8.3% versus 3.5%) more frequently. Conclusions Peritoneal dialysis eligibility and choice were not associated with socioeconomic status. However, socioeconomic status may influence specific barriers to peritoneal dialysis choice. Additional studies to determine the effect of targeting interventions to specific barriers to peritoneal dialysis choice in low socioeconomic status patients on peritoneal dialysis use are needed. PMID:23970135
Neighborhood socioeconomic status and barriers to peritoneal dialysis: a mixed methods study.
Prakash, Suma; Perzynski, Adam T; Austin, Peter C; Wu, C Fangyun; Lawless, Mary Ellen; Paterson, J Michael; Quinn, Rob R; Sehgal, Ashwini R; Oliver, Matthew James
2013-10-01
The objective of this study was to evaluate the association between neighborhood socioeconomic status and barriers to peritoneal dialysis eligibility and choice. This study was a mixed methods parallel design study using quantitative and qualitative data from a prospective clinical database of ESRD patients. The eligibility and choice cohorts were assembled from consecutive incident chronic dialysis patients entering one of five renal programs in the province of Ontario, Canada, between January 1, 2004 and December 31, 2010. Socioeconomic status was measured as median household income and percentage of residents with at least a high school education using Statistics Canada dissemination area-level data. Multivariable models described the relationship between socioeconomic status and likelihood of peritoneal dialysis eligibility and choice. Barriers to peritoneal dialysis eligibility and choice were classified into qualitative categories using the thematic constant comparative approach. The peritoneal dialysis eligibility and choice cohorts had 1314 and 857 patients, respectively; 65% of patients were deemed eligible for peritoneal dialysis, and 46% of eligible patients chose peritoneal dialysis. Socioeconomic status was not a significant predictor of peritoneal dialysis eligibility or choice in this study. Qualitative analyses identified 16 barriers to peritoneal dialysis choice. Patients in lower- versus higher-income Statistics Canada dissemination areas cited built environment or space barriers to peritoneal dialysis (4.6% versus 2.7%) and family or social support barriers (8.3% versus 3.5%) more frequently. Peritoneal dialysis eligibility and choice were not associated with socioeconomic status. However, socioeconomic status may influence specific barriers to peritoneal dialysis choice. Additional studies to determine the effect of targeting interventions to specific barriers to peritoneal dialysis choice in low socioeconomic status patients on peritoneal dialysis use are needed.
Dunne, Nina; Campbell, Malcolm; Fitzpatrick, Maggie; Callery, Peter
2014-06-01
The National Kidney Foundation-Dialysis Outcomes Quality Initiative (KDOQI) guidelines and the Renal Association recommend the use of either Kt/V or urea reduction ratio (URR) to measure haemodialysis adequacy. To determine the methods used to measure paediatric haemodialysis adequacy and to assess consistency between calculations of single pool Kt/V (spKt/V) and URR. A service evaluation was conducted to establish current practices in measuring dialysis adequacy. A prospective longitudinal study was conducted to compare spKt/V and URR. Thirty-two children were recruited consisting of 13 males and 19 females in five paediatric dialysis centres. Inconsistencies were reported of the method of post-urea sampling with 4 of the 10 centres using the KDOQI recommended sampling method. Five dialysis centres reported using URR and five reported using spKt/V. There were substantial differences between the two measures. Using URR suggested that up to 44% of children did not receive adequate dialysis, whereas measurement by spKt/V suggested no more than 6% of the same dialysis sessions were not adequate. One standard measure should be used to assess dialysis adequacy in paediatric centres in England. KDOQI guidelines were not consistently followed in obtaining a post-urea blood sample and this procedure should be standardised. © 2014 European Dialysis and Transplant Nurses Association/European Renal Care Association.
Convex formulation of multiple instance learning from positive and unlabeled bags.
Bao, Han; Sakai, Tomoya; Sato, Issei; Sugiyama, Masashi
2018-05-24
Multiple instance learning (MIL) is a variation of traditional supervised learning problems where data (referred to as bags) are composed of sub-elements (referred to as instances) and only bag labels are available. MIL has a variety of applications such as content-based image retrieval, text categorization, and medical diagnosis. Most of the previous work for MIL assume that training bags are fully labeled. However, it is often difficult to obtain an enough number of labeled bags in practical situations, while many unlabeled bags are available. A learning framework called PU classification (positive and unlabeled classification) can address this problem. In this paper, we propose a convex PU classification method to solve an MIL problem. We experimentally show that the proposed method achieves better performance with significantly lower computation costs than an existing method for PU-MIL. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ning, Xun-An; Zhou, Yun; Liu, Jing-Yong; Wang, Jiang-Hui; Li, Lei; Ma, Xiao-Guo
2011-09-01
A method of microwave digestion technique-flame atomic absorption spectrometry was proposed to determine the total contents of Cu, Zn, Pb, Cd, Cr and Ni in five different kinds of waste bag filters from a steel plant. The digestion effects of the six acid systems on the heavy metals digestion were studied for the first time. The relative standard deviation (RSD) of the method was between 1.02% and 9.35%, and the recovery rates obtained by standard addition method ranged from 87.7% to 105.6%. The results indicated that the proposed method exhibited the advantages of simplicity, speediness, accuracy and repeatability, and it was suitable for determining the metal elements of the waste bag filter. The results also showed that different digestion systems should be used according to different waste bag filters. The waste bag filter samples from different production processes had different metal elements content. The Pb and Zn were the highest in the waste bag filters, while the Cu, Ni, Cd and Cr were relatively lower. These determination results provided the scientific data for further treatment and disposal of the waste bag filter.
49 CFR 178.518 - Standards for woven plastic bags.
Code of Federal Regulations, 2011 CFR
2011-10-01
... plastic bag; (2) 5H2 for a sift-proof woven plastic bag; and (3) 5H3 for a water-resistant woven plastic... other equally strong method of closure. (3) Bags, sift-proof, 5H2 must be made sift-proof by appropriate...
Lepper-Blilie, A N; Berg, E P; Buchanan, D S; Keller, W L; Maddock-Carlin, K R; Berg, P T
2014-03-01
A 3×3×2 factorial was utilized to determine if roast size (small, medium, large), cooking method (open-pan, oven bag, vacuum bag), and heating process (fresh, reheated) prevented warmed-over flavor (WOF) in beef clod roasts. Fresh vacuum bag and reheated open-pan roasts had higher cardboardy flavor scores compared with fresh open-pan roast scores. Reheated roasts in oven and vacuum bags did not differ from fresh roasts for cardboardy flavor. Brothy and fat intensity were increased in reheated roasts in oven and vacuum bags compared with fresh roasts in oven and vacuum bags. Differences in TBARS were found in the interaction of heating process and roast size with the fresh and reheated large, and reheated medium roasts having the lowest values. Based on TBARS data, to prevent WOF in reheated beef roasts, a larger size roast in a cooking bag is the most effective method. Copyright © 2013 Elsevier Ltd. All rights reserved.
El-Reshaid, Wael; Al-Disawy, Hanan; Nassef, Hossameldeen; Alhelaly, Usama
2016-09-01
Peritonitis is a common complication in patients undergoing continuous ambulatory peritoneal dialysis (CAPD) and automated peritoneal dialysis (APD). In this retrospective study, peritonitis rates and patient survival of 180 patients on CAPD and 128 patients on APD were compared in the period from January 2005 to December 2014 at Al-Nafisi Center in Kuwait. All patients had prophylactic topical mupirocin at catheter exit site. Patients on CAPD had twin bag system with Y transfer set. The peritonitis rates were 1 in 29 months in CAPD and 1 in 38 months in APD (p < 0.05). Percentage of peritonitis free patients over 10-year period in CAPD and APD were 49 and 60%, respectively (p < 0.05). Time to develop peritonitis was 10.25 ± 3.1 months in CAPD compared to 16.1 ± 4 months in APD (p < 0.001). Relapse and recurrence rates were similar in both groups. Median patient survival in CAPD and APD groups with peritonitis was 13.1 ± 1 and 14 ± 1.4 months respectively (p = 0.3) whereas in peritonitis free patients it was 15 ± 1.4 months in CAPD and 23 ± 3.1 months in APD (p = 0.025). APD had lower incidence rate of peritonitis than CAPD. Patient survival was better in APD than CAPD in peritonitis free patients but was similar in patients who had peritonitis.
Persistence of marine fish environmental DNA and the influence of sunlight
Andruszkiewicz, Elizabeth A.; Sassoubre, Lauren M.
2017-01-01
Harnessing information encoded in environmental DNA (eDNA) in marine waters has the potential to revolutionize marine biomonitoring. Whether using organism-specific quantitative PCR assays or metabarcoding in conjunction with amplicon sequencing, scientists have illustrated that realistic organism censuses can be inferred from eDNA. The next step is establishing ways to link information obtained from eDNA analyses to actual organism abundance. This is only possible by understanding the processes that control eDNA concentrations. The present study uses mesocosm experiments to study the persistence of eDNA in marine waters and explore the role of sunlight in modulating eDNA persistence. We seeded solute-permeable dialysis bags with water containing indigenous eDNA and suspended them in a large tank containing seawater. Bags were subjected to two treatments: half the bags were suspended near the water surface where they received high doses of sunlight, and half at depth where they received lower doses of sunlight. Bags were destructively sampled over the course of 87 hours. eDNA was extracted from water samples and used as template for a Scomber japonicus qPCR assay and a marine fish-specific 12S rRNA PCR assay. The latter was subsequently sequenced using a metabarcoding approach. S. japonicus eDNA, as measured by qPCR, exhibited first order decay with a rate constant ~0.01 hr -1 with no difference in decay rate constants between the two experimental treatments. eDNA metabarcoding identified 190 organizational taxonomic units (OTUs) assigned to varying taxonomic ranks. There was no difference in marine fish communities as measured by eDNA metabarcoding between the two experimental treatments, but there was an effect of time. Given the differences in UVA and UVB fluence received by the two experimental treatments, we conclude that sunlight is not the main driver of fish eDNA decay in the experiments. However, there are clearly temporal effects that need to be considered when interpreting information obtained using eDNA approaches. PMID:28915253
Persistence of marine fish environmental DNA and the influence of sunlight.
Andruszkiewicz, Elizabeth A; Sassoubre, Lauren M; Boehm, Alexandria B
2017-01-01
Harnessing information encoded in environmental DNA (eDNA) in marine waters has the potential to revolutionize marine biomonitoring. Whether using organism-specific quantitative PCR assays or metabarcoding in conjunction with amplicon sequencing, scientists have illustrated that realistic organism censuses can be inferred from eDNA. The next step is establishing ways to link information obtained from eDNA analyses to actual organism abundance. This is only possible by understanding the processes that control eDNA concentrations. The present study uses mesocosm experiments to study the persistence of eDNA in marine waters and explore the role of sunlight in modulating eDNA persistence. We seeded solute-permeable dialysis bags with water containing indigenous eDNA and suspended them in a large tank containing seawater. Bags were subjected to two treatments: half the bags were suspended near the water surface where they received high doses of sunlight, and half at depth where they received lower doses of sunlight. Bags were destructively sampled over the course of 87 hours. eDNA was extracted from water samples and used as template for a Scomber japonicus qPCR assay and a marine fish-specific 12S rRNA PCR assay. The latter was subsequently sequenced using a metabarcoding approach. S. japonicus eDNA, as measured by qPCR, exhibited first order decay with a rate constant ~0.01 hr -1 with no difference in decay rate constants between the two experimental treatments. eDNA metabarcoding identified 190 organizational taxonomic units (OTUs) assigned to varying taxonomic ranks. There was no difference in marine fish communities as measured by eDNA metabarcoding between the two experimental treatments, but there was an effect of time. Given the differences in UVA and UVB fluence received by the two experimental treatments, we conclude that sunlight is not the main driver of fish eDNA decay in the experiments. However, there are clearly temporal effects that need to be considered when interpreting information obtained using eDNA approaches.
Wieczorowska-Tobis, K; Polubinska, A; Wisniewska, J; Pawlaczyk, K; Kuzlan-Pawlaczyk, M; Filas, V; Breborowicz, A; Oreopoulos, D G
2001-03-01
Peritoneal dialysis causes the functional and morphological changes in the peritoneum that result from the bioincompatibility of dialysis solutions. We present a model of chronic peritoneal dialysis in the rat that can be used for testing the biocompatibility of dialysis fluids. Methods and Results. Long-term exposure of the peritoneum to dialysis solutions can be performed in rats with implanted peritoneal catheters. Sampling of the dialysate allows the evaluation of intraperitoneal inflammation by examining cell differential and dialysate cytokine levels. Peritoneal permeability can be evaluated at designed time intervals with the peritoneal equilibration test (PET). At the end of dialysis, peritoneal histology is studied with light and electron microscopy. Such a multidirectional approach is an effective way to test biocompatibility of dialysis solutions.
Solid lipid nanoparticles for enhancing vinpocetine's oral bioavailability.
Luo, YiFan; Chen, DaWei; Ren, LiXiang; Zhao, XiuLi; Qin, Jing
2006-08-10
An ultrasonic-solvent emulsification technique was adopted to prepare vinpocetine loaded Glyceryl monostearate (GMS) nanodispersions with narrow size distribution. To increase the lipid load the process was conducted at 50 degrees C, and in order to prepare nanoparticle using an ultrasonic-solvent emulsification technique. The mean particle size and droplet size distribution, drug loading capacity, drug entrapment efficiency (EE%), zeta potential, and long-term physical stability of the SLNs were investigated in detail respectively. Drug release from two sorts of VIN-SLN was studied using a dialysis bag method. A pharmacokinetic study was conducted in male rats after oral administration of 10 mg kg(-1) VIN in different formulations, it was found that the relative bioavailability of VIN in SLNs was significantly increased compared with that of the VIN solution. The amount of surfactant also had a marked effect on the oral absorption of VIN with SLN formulations. The absorption mechanism of the SLN formulations was also discussed. These results indicated that VIN absorption is enhanced significantly by employing SLN formulations. SLNs offer a new approach to improve the oral bioavailability of poorly soluble drugs.
Precise method for the measurement of catalase activity in honey.
Huidobro, José F; Sánchez, M Pilar; Muniategui, Soledad; Sancho, M Teresa
2005-01-01
An improved method is reported for the determination of catalase activity in honey. We tested different dialysis membranes, dialysis fluid compositions and amounts, dialysis temperatures, sample amounts, and dialysis times. The best results were obtained by dialysis of 7.50 g sample in a cellulose dialysis sack, using two 3 L portions of 0.015 M sodium phosphate buffer (pH 7.0) as the dialysis fluid at 4 degrees C for 22 h. As in previous methods, catalase activity was determined on the basis of the rate of disappearance of the substrate, H202, with the H202 determined spectrophotometrically at 400 nm in an assay system containing o-dianisidine and peroxidase. Trials indicated that the best solvent for the o-dianisidine was 0.2 M sodium phosphate buffer, pH 6.1; the best starting H202 concentration was 3 mM; the best HCl concentration for stopping the reaction was 6 N; and the best sample volume for catalase measurement was 7.0 mL. Precision values (relative standard deviations for analyses of 10 subsamples of each of 3 samples) were high, ranging from 0.48% for samples with high catalase activity to 1.98% for samples with low catalase activity.
NASA Technical Reports Server (NTRS)
1992-01-01
Organon Teknika Corporation's REDY 2000 dialysis machine employs technology originally developed under NASA contract by Marquardt Corporation. The chemical process developed during the project could be applied to removing toxic waste from used dialysis fluid. This discovery led to the development of a kidney dialysis machine using "sorbent" dialysis, a method of removing urea from human blood by treating a dialysate solution. The process saves electricity and, because the need for a continuous water supply is eliminated, the patient has greater freedom.
Assessment of the mobile bag method for estimation of in vivo starch digestibility.
Ghoorchi, T; Lund, P; Larsen, M; Hvelplund, T; Hansen-Møller, J; Weisbjerg, M R
2013-02-01
The objective was to assess the ability of the in situ mobile nylon bag method for predicting small intestinal and total tract starch digestibility. Starch disappearance was measured for 18 samples of different cereals and legumes subjected to different physical and chemical processing methods and compared with coherent in vivo digestibility. Starch disappearance was measured both with and without initial ruminal pre-incubation during 4 h. Bags were retrieved from either the ileal cannula or faeces. Two dry Danish Holstein cows fitted with rumen cannulas were used for rumen pre-incubations and two lactating Danish Holstein cows fitted with duodenal and ileal cannulas were used for intestinal incubations. Rumen pre-incubation had no significant effect on disappearance from bags recovered in faeces. The disappearance of legume starch was lower, both in the rumen and small intestine, compared with starch from barley, wheat, oats, ear maize and maize. Transit times of the mobile bags from duodenum to ileum were not significantly different between feeds. A weak positive correlation was found between in vivo small intestinal and total tract digestibility of starch and disappearance obtained using the mobile bag technique across a broad range of starch sources. Omitting two less conventional starch sources (NaOH wheat and xylose-treated barley) resulted in a high (0.87) correlation between total tract in vivo digestibility and mobile bag disappearance. The use of the mobile bag method for estimation of in vivo starch digestibility will therefore depend on the starch type.
A New Fast, Reliable Technique for the Sampling of Dissolved Inorganic Carbon in Sea Ice
NASA Astrophysics Data System (ADS)
Hu, Y.; Wang, F.; Rysgaard, S.; Barber, D. G.
2015-12-01
For a long time, sea ice was considered to act as a lid over seawater preventing CO2 exchange between the atmosphere and ocean. Recent observations suggest that sea ice can be an active source or a sink for CO2, although its magnitude is not very clear. The direct measurements on CO2 flux based on the chamber method and eddy covariance often do not agree with each other. It is therefore important to measure the dissolved inorganic carbon (DIC) stock in sea ice precisely in order to better understand the CO2 flux through sea ice. The challenges in sea ice DIC sampling is how to melt the ice core without being exposed to the air gaining or losing CO2. A common practice is to seal the ice core in a self-prepared gas-tight plastic bag and suck the air out of the bag gently using a syringe (together with a needle) through a valve mounted on one side of the bag. However, this method is time consuming (takes up to several minutes to suck the air out) and very often there is large headspace found in the bag after the ice melts due to the imperfect bag-preparation, which might affect the DIC concentration in melt ice-water. We developed a new technique by using a commercially available plastic bag with a vacuum sealer to seal the ice core. In comparison to syringe-based method, this technique is fast and easy to operate; it takes less than 10 seconds to vacuum and seal the bag all in one button with no headspace left in the bag. Experimental tests with replicate ice cores sealed by those two methods showed that there is no difference in the DIC concentration measured after these two methods, suggesting that there is no loss of DIC during the course of vacuum sealing. In addition, a time series experiment on DIC in melt ice-water stored in the new bag shows that when the samples were not poisoned, the DIC concentration remains unchanged for at least 3 days in the bag; while poisoned by HgCl2, there is no change in DIC for at least 21 days, indicating that this new bag is impermeable to CO2. Therefore, this new technique offers a convenient yet reliable method for DIC sampling of sea ice.
Nutritional assessment of elderly patients on dialysis: pitfalls and potentials for practice.
Rodrigues, Juliana; Cuppari, Lilian; Campbell, Katrina L; Avesani, Carla Maria
2017-11-01
The chronic kidney disease (CKD) population is aging. Currently a high percentage of patients treated on dialysis are older than 65 years. As patients get older, several conditions contribute to the development of malnutrition, namely protein energy wasting (PEW), which may be compounded by nutritional disturbances associated with CKD and from the dialysis procedure. Therefore, elderly patients on dialysis are vulnerable to the development of PEW and awareness of the identification and subsequent management of nutritional status is of importance. In clinical practice, the nutritional assessment of patients on dialysis usually includes methods to assess PEW, such as the subjective global assessment, the malnutrition inflammation score, and anthropometric and laboratory parameters. Studies investigating measures of nutritional status specifically tailored to the elderly on dialysis are scarce. Therefore, the same methods and cutoffs used for the general adult population on dialysis are applied to the elderly. Considering this scenario, the aim of this review is to discuss specific considerations for nutritional assessment of elderly patients on dialysis addressing specific shortcomings on the interpretation of markers, in addition to providing clinical practice guidance to assess the nutritional status of elderly patients on dialysis. © The Author 2017. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Partitioning of fluorotelomer alcohols to octanol and different sources of dissolved organic carbon.
Carmosini, Nadia; Lee, Linda S
2008-09-01
Interest in the environmental fate of fluorotelomer alcohols (FTOHs) has spurred efforts to understand their equilibrium partitioning behavior. Experimentally determined partition coefficients for FTOHs between soil/water and air/water have been reported, but direct measurements of partition coefficients for dissolved organic carbon (DOC)/water (K(doc)) and octanol/ water(K(ow)) have been lacking. Here we measured the partitioning of 8:2 and 6:2 FTOH between one or more types of DOC and water using enhanced solubility or dialysis bag techniques, and also quantified K(ow) values for 4:2 to 8:2 FTOH using a batch equilibration method. The range in measured log K(doc) values for 8:2 FTOH using the enhanced solubility technique with DOC derived from two soils, two biosolids, and three reference humic acids is 2.00-3.97 with the lowest values obtained for the biosolids and an average across all other DOC sources (biosolid DOC excluded) of 3.54 +/- 0.29. For 6:2 FTOH and Aldrich humic acid, a log K(doc) value of 1.96 +/- 0.45 was measured using the dialysis technique. These average values are approximately 1 to 2 log units lower than previously indirectly estimated K(doc) values. Overall, the affinity for DOC tends to be slightly lower than that for particulate soil organic carbon. Measured log K(ow) values for 4:2 (3.30 +/- 0.04), 6:2 (4.54 +/- 0.01), and 8:2 FTOH (5.58 +/- 0.06) were in good agreement with previously reported estimates. Using relationships between experimentally measured partition coefficients and C-atom chain length, we estimated K(doc) and K(ow) values for shorter and longer chain FTOHs, respectively, that we were unable to measure experimentally.
Lipid globule size in total nutrient admixtures prepared in three-chamber plastic bags.
Driscoll, David F; Thoma, Andrea; Franke, Rolf; Klütsch, Karsten; Nehne, Jörg; Bistrian, Bruce R
2009-04-01
The stability of injectable lipid emulsions in three-chamber plastic (3CP) bags, applying the globule-size limits established by United States Pharmacopeia ( USP ) chapter 729, was studied. A total of five premixed total nutrient admixture (TNA) products packaged in 3CP bags from two different lipid manufacturers containing either 20% soybean oil or a mixture of soybean oil and medium-chain-triglyceride oil as injectable lipid emulsions were tested. Two low-osmolarity 3CP bags and three high-osmolarity 3CP bags were studied. All products were tested with the addition of trace elements and multivitamins. All additive conditions (with and without electrolytes) were tested in triplicate at time 0 (immediately after mixing) and at 6, 24, 30, and 48 hours after mixing; the bags were stored at 24-26 degrees C. All additives were equally distributed in each bag for comparative testing, applying both globule sizing methods outlined in USP chapter 729. Of the bags tested, all bags from one manufacturer were coarse emulsions, showing signs of significant growth in the large-diameter tail when mixed as a TNA formulation and failing the limits set by method II of USP chapter 729 from the outset and throughout the study, while the bags from the other manufacturer were fine emulsions and met these limits. Of the bags that failed, significant instability was noted in one series containing additional electrolytes. Injectable lipid emulsions provided in 3CP bags that did not meet the globule-size limits of USP chapter 729 produced coarser TNA formulations than emulsions that met the USP limits.
What's in the Bag (and Why?): Tangibilia for the Classroom.
ERIC Educational Resources Information Center
Ogier, James M.
A classroom technique designed for developing German second language vocabulary is expanded on for additional classroom functions and activities. The method uses a bag containing a variety of objects. The objects are drawn out of the bag and discussed in class. The contents of the bag should be unpredictable and unusual, and they should be changed…
Bolasco, Piergiorgio; Contu, Antonio; Meloni, Patrizia; Vacca, Dorio; Galfrè, Andrea
2012-01-01
Methods: The present report attempts to illustrate the positive impact on the microbiological quality of dialysis patients over a 15-year period through the progressive implementation of state-of-the-art technological strategies and the optimization of microbiological surveillance procedures in five dialysis units in Sardinia. Results: Following on better microbiological, quality controls of dialysis water and improvement of procedures and equipment, a drastic improvement of microbiological water quality was observed in a total of 945 samples. The main aim was to introduce the use of microbiological culture methods as recommended by the most important guidelines. The microbiological results obtained have led to a progressive refining of controls and introduction of new materials and equipment, including two-stage osmosis and piping distribution rings featuring a greater capacity to prevent biofilm adhesion. The actions undertaken have resulted in unexpected quality improvements. Conclusions: Dialysis water should be viewed by the nephrologist as a medicinal product exerting a demonstrable positive impact on microinflammation in dialysis patients. A synergic effort between nephrologists and microbiologists undoubtedly constitutes the most effective means of preventing dialysis infections. PMID:23066395
Water bag modeling of a multispecies plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morel, P.; Gravier, E.; Besse, N.
2011-03-15
We report in the present paper a new modeling method to study multiple species dynamics in magnetized plasmas. Such a method is based on the gyrowater bag modeling, which consists in using a multistep-like distribution function along the velocity direction parallel to the magnetic field. The choice of a water bag representation allows an elegant link between kinetic and fluid descriptions of a plasma. The gyrowater bag model has been recently adapted to the context of strongly magnetized plasmas. We present its extension to the case of multi ion species magnetized plasmas: each ion species being modeled via a multiwatermore » bag distribution function. The water bag modelization will be discussed in details, under the simplification of a cylindrical geometry that is convenient for linear plasma devices. As an illustration, results obtained in the linear framework for ion temperature gradient instabilities are presented, that are shown to agree qualitatively with older works.« less
The research on medical image classification algorithm based on PLSA-BOW model.
Cao, C H; Cao, H L
2016-04-29
With the rapid development of modern medical imaging technology, medical image classification has become more important for medical diagnosis and treatment. To solve the existence of polysemous words and synonyms problem, this study combines the word bag model with PLSA (Probabilistic Latent Semantic Analysis) and proposes the PLSA-BOW (Probabilistic Latent Semantic Analysis-Bag of Words) model. In this paper we introduce the bag of words model in text field to image field, and build the model of visual bag of words model. The method enables the word bag model-based classification method to be further improved in accuracy. The experimental results show that the PLSA-BOW model for medical image classification can lead to a more accurate classification.
Biological significance of reducing glucose degradation products in peritoneal dialysis fluids.
Wieslander, A; Linden, T; Musi, B; Carlsson, O; Deppisch, R
2000-01-01
Carbohydrates are not stable when exposed to energy; they degrade into new molecules. In peritoneal dialysis (PD) fluids, degradation of glucose occurs during the heat sterilization procedure. The biological consequences of this degradation are side effects such as impaired proliferation and impaired host defense mechanisms, demonstrated in vitro for a great variety of cells. Several highly toxic compounds--such as formaldehyde and 3-deoxyglucosone--have been identified in PD fluids. Carbonyl compounds, apart from being cytotoxic, are also well-known promoters of irreversible advanced glycation end-products (AGEs), which might participate in the long-term remodeling of the peritoneal membrane. Various approaches can be used to reduce the formation of glucose degradation products (GDPs) during heat sterilization. Some examples are shortening the sterilization time, lowering the pH, removing catalyzing substances, and increasing glucose concentration. The latter three factors are employed in the multi-compartment bag with a separate chamber containing pure glucose at high concentration and low pH. Gambrosol trio, a PD fluid produced in this way, shows reduced cytotoxicity, normalized host defense reactions, less AGE formation, and reduced concentrations of formaldehyde and 3-deoxyglucosone. Moreover, in the clinical situation, the fluid turns out to be more biocompatible for the patient, causing less mesothelial cell damage, which in the long term could lead to a more intact peritoneal membrane. Glucose degradation products in heat-sterilized fluids for peritoneal dialysis are cytotoxic, promote AGE formation, and cause negative side effects for the patient. Using improved and well-controlled manufacturing processes, it is possible to produce sterile PD fluids with glucose as the osmotic agent but without the negative side effects related to GDPs.
Wang, Yuling; Zhang, Xinfu; Wang, Ran; Bai, Yingxin; Liu, Chenglian; Yuan, Yongbing; Yang, Yingjie; Yang, Shaolan
2017-01-01
Preharvest bagging is a simple, grower-friendly and safe physical protection technique commonly applied to many fruits, and the application of different fruit bags can have various effects. To explore the molecular mechanisms underlying the fruit quality effects of different bagging treatments, digital gene expression (DGE) profiling of bagged and unbagged ‘Chili’ (Pyrus bretschneideri Rehd.) pear pericarp during development was performed. Relative to unbagged fruit, a total of 3022 and 769 differentially expressed genes (DEGs) were detected in the polyethylene (PE)-bagged and non-woven fabric-bagged fruit, respectively. DEGs annotated as photosynthesis-antenna proteins and photosynthesis metabolism pathway were upregulated in non-woven fabric-bagged fruit but downregulated in the PE-bagged fruit. Non-woven fabric bagging inhibited lignin synthesis in ‘Chili’ pear pericarp by downregulating DEGs involved in phenylpropanoid biosynthesis; consequently, the fruit lenticels in non-woven fabric-bagged fruit were smaller than those in the other treatments. The results indicate that the non-woven fabric bagging method has a positive effect on the appearance of ‘Chili’ pear fruit but neither of the two bagging treatments is conducive to the accumulation of soluble sugar. PMID:28280542
Akhoond Zardini, Ali; Mohebbi, Mohebbat; Farhoosh, Reza; Bolurian, Shadi
2018-01-01
In this study, lycopene, was loaded on nanostructured lipid carrier and solid lipid nanoparticles using combination of high shear homogenization and ultrasonication method. Effect of applied lipids types, nanocarrier's type and lycopene loading on physicochemical properties of developed nanocarriers were studied. Particle sizes of developed nanocarriers were between 74.93 and 183.40 nm. Encapsulation efficiency of nanostructured lipid carrier was significantly higher than solid lipid nanoparticles. Morphological study of developed nanocarriers using scanning electron microscopy showed spherical nanoparticles with smooth surface. Lycopene was entrapped in nanocarriers without any chemical interaction with coating material according to Fourier transform infrared spectroscopy spectrum and differential scanning calorimetry thermogram. Glycerol monostearate containing nanoparticles showed phase separation after 30 days in 6 and 25 °C, whereas this event was not observed in nanosuspensions that produced by glycerol distearate. Lycopene release in gastrointestinal condition was studied by the dialysis bag method. To evaluate nanocarrier's potential for food fortification, developed lycopene-loaded nanocarriers were added to orange drink. Results of sensory analysis indicated that nanoencapsulation could obviate the poor solubility and tomato after taste of lycopene. Fortified sample with lycopene nanocarriers didn't show significant difference with blank orange drink sample except in orange odor.
[Problems of peritoneal dialysis--history and research perspectives].
Czyzewska, Krystyna; Grzelak, Teresa; Szary, Beata
2009-01-01
This paper specifies the peritoneal dialysis problems as a method of renal replacement therapy in a historical perspective. It pointed out to the dynamic development of peritoneal dialysis in the nineties and distinct slump of the presented treatment form at the turn of XXth and XXIst century, despite substantial progress in the dialysis techniques, effectiveness and biocompatibility of the therapy as well as a detailed evaluation of peritoneal function in vivo and in vitro. It showed descriptions and outline of the peritoneal cavity dating from ancient times, 19th-century animal experiments determining essential laws of peritoneal absorption and removal molecules, as well as the first peritoneal dialysis of a man which took place at the beginning of the 20th-century. The technical problems and peritonitis were the fundamental limitations of this therapy employment in this phase of dialysis development. The application of Tenckhoffs catheter and the technique specified as continuous ambulatory peritoneal dialysis was the invention and at the same time, the turning point which decided about the considerable progress of the described method of dialysis in the nineties. In this period, the analyses concerning failures of the peritoneal transport functions and protection of peritoneum during its long-term use as a dialysis membrane dominated. These studies referred to not absolutely biocompatibility factors of the environment of the peritoneal cavity during peritoneal dialysis. Thence, proposed future directions of analyses include researches concerning components of dialysis solution to assure long-term preservation of peritoneal transport functions and its secretory properties. It is not excluded that experiments of applying the newest achievements of regenerative medicine, in the scope of genetic modification and implantation of mesothelial cells will be continued.
BAG3 promotes chondrosarcoma progression by upregulating the expression of β-catenin
Shi, Huijuan; Chen, Wenfang; Dong, Yu; Lu, Xiaofang; Zhang, Wenhui; Wang, Liantang
2018-01-01
To investigate the roles of B-cell lymphoma-2 associated athanogene 3 (BAG3) in human chondrosarcoma and the potential mechanisms, the expression levels of BAG3 were detected in the present study, and the associations between BAG3 and clinical pathological parameters, clinical stage as well as the survival of patients were analyzed. The present study detected BAG3 mRNA and protein expression in the normal cartilage cell line HC-a and in SW1353 chondrosarcoma cells by reverse transcription-quantitative polymerase chain reaction and western blot analysis. The BAG3 protein expression in 59 cases of chondrosarcoma, 30 patients with endogenous chondroma and 8 cases of normal cartilage was semi-quantitatively analyzed using the immunohistochemical method. In addition, the BAG3 protein expression level, the clinical pathological parameters, clinical stage and the survival time of patients with chondrosarcoma were analyzed. The plasmid transfection method was employed to upregulate the expression BAG3 and small RNA interference to downregulate the expression of BAG3 in SW1353 cells. The expression levels of BAG3 protein and mRNA were significantly increased in the chondrosarcoma cell line when compared with the normal cartilage cell line. The immunohistochemistry results indicated that BAG3 protein was overexpressed in the tissue of human chondrosarcoma. Statistical analysis showed that the expression level of BAG3 was significantly increased in the different Enneking staging of patients with chondrosarcoma and Tumor staging, and there were no statistical differences in age, gender, histological classification and tumor size. In the in vitro experiments, the data revealed that BAG3 significantly promoted chondrosarcoma cell proliferation, colony-formation, migration and invasion; however, it inhibited chondrosarcoma cell apoptosis. It was observed that BAG3 upregulated β-catenin expression at the mRNA and protein levels. In addition, BAG3 induced the expression of runt-related transcription factor 2 (RUNX2) in chondrosarcoma cells by upregulating β-catenin. These clinical analyses revealed a positive association between β-catenin and BAG3 in chondrosarcoma tumors. BAG3 was significantly increased in chondrosarcoma cells and tissues compared with the normal cartilage cells, tissue and cartilage benign tumors. Thus, BAG3 may serve as an oncogene in the development of chondrosarcoma via the induction of RUNX2 expression. The results of the present study contribute to further research on the biological development of chondrosarcoma. PMID:29484408
Method of reusably sealing a silicone rubber vacuum bag to a mold for composite manufacture
NASA Technical Reports Server (NTRS)
Steinbach, John (Inventor)
1989-01-01
A silicone rubber vacuum bag for use in composite article manufacture is reusably sealed to a mold, without mechanical clamping means. The mold-mating portion of the bag is primed with a silicone rubber adhesive, which is cured thereto, and a layer of semiadhesive sealer is applied between the primed mold-mating portion of the bag and the mold.
[A rapid dialysis method for analysis of artificial sweeteners in food].
Tahara, Shoichi; Fujiwara, Takushi; Yasui, Akiko; Hayafuji, Chieko; Kobayashi, Chigusa; Uematsu, Yoko
2014-01-01
A simple and rapid dialysis method was developed for the extraction and purification of four artificial sweeteners, namely, sodium saccharin (Sa), acesulfame potassium (AK), aspartame (APM), and dulcin (Du), which are present in various foods. Conventional dialysis uses a membrane dialysis tube approximately 15 cm in length and is carried out over many hours owing to the small membrane area and owing to inefficient mixing. In particular, processed cereal products such as cookies required treatment for 48 hours to obtain satisfactory recovery of the compounds. By increasing the tube length to 55 cm and introducing efficient mixing by inversion at half-hour intervals, the dialysis times of the four artificial sweeteners, spiked at 0.1 g/kg in the cookie, were shortened to 4 hours. Recovery yields of 88.9-103.2% were obtained by using the improved method, whereas recovery yields were low (65.5-82.0%) by the conventional method. Recovery yields (%) of Sa, AK, APM, and Du, spiked at 0.1 g/kg in various foods, were 91.6-100.1, 93.9-100.1, 86.7-100.0 and 88.7-104.7 using the improved method.
"Who matters most?": Clinician perspectives of influence and recommendation on home dialysis uptake.
Walker, Rachael C; Marshall, Roger; Howard, Kirsten; Morton, Rachael L; Marshall, Mark R
2017-12-01
There is little research exploring the association between clinicians' behaviours and home dialysis uptake. This paper aims to better understand the influence of clinicians on home dialysis modality recommendations and uptake. Online survey of all NZ renal units to determine the influence of individuals within pre-dialysis teams. We used the self-declaration scale of influence to rate the identified member's perceived influence on decision-making. We used this measure of 'decisional power' to compare the perceived influence of pre-dialysis nurses with nephrologists using both parametric and non-parametric methods. We developed a generalized linear model to investigate the relationship between the influence of nephrologists and pre-dialysis nurses with home dialysis uptake by individual centre using additional data from Australian and New Zealand Dialysis and Transplant Registry (ANZDATA). Finally, respondents rated the importance of a list of patient and service-level factors in recommendations for home dialysis. Data suggest the nephrologists are the most influential member of the pre-dialysis team. This contrasts with perceptions of survey respondents who view pre-dialysis nurses as most influential. Nephrologists' recommendations are likely to be a successful way of increasing home dialysis. A single point increase in nephrologist decisional power is associated with a 6.1% increase in the prevalence of home dialysis. The decisional power around home dialysis in NZ sits with nephrologists. It is therefore critical that nephrologists exercise their decisional power in advocating home dialysis and address reasons why they may not recommend home dialysis to well-suited and appropriate patients. © 2016 Asian Pacific Society of Nephrology.
Visual attention based bag-of-words model for image classification
NASA Astrophysics Data System (ADS)
Wang, Qiwei; Wan, Shouhong; Yue, Lihua; Wang, Che
2014-04-01
Bag-of-words is a classical method for image classification. The core problem is how to count the frequency of the visual words and what visual words to select. In this paper, we propose a visual attention based bag-of-words model (VABOW model) for image classification task. The VABOW model utilizes visual attention method to generate a saliency map, and uses the saliency map as a weighted matrix to instruct the statistic process for the frequency of the visual words. On the other hand, the VABOW model combines shape, color and texture cues and uses L1 regularization logistic regression method to select the most relevant and most efficient features. We compare our approach with traditional bag-of-words based method on two datasets, and the result shows that our VABOW model outperforms the state-of-the-art method for image classification.
Comparison of outcomes for veterans receiving dialysis care from VA and non-VA providers
2013-01-01
Background Demand for dialysis treatment exceeds its supply within the Veterans Health Administration (VA), requiring VA to outsource dialysis care by purchasing private sector dialysis for veterans on a fee-for-service basis. It is unclear whether outcomes are similar for veterans receiving dialysis from VA versus non-VA providers. We assessed the extent of chronic dialysis treatment utilization and differences in all-cause hospitalizations and mortality between veterans receiving dialysis from VA versus VA-outsourced providers. Methods We constructed a retrospective cohort of veterans in 2 VA regions who received chronic dialysis treatment financed by VA between January 2007 and December 2008. From VA administrative data, we identified veterans who received outpatient dialysis in (1) VA, (2) VA-outsourced settings, or (3) both (“dual”) settings. In adjusted analyses, we used two-part and logistic regression to examine associations between dialysis setting and all-cause hospitalization and mortality one-year from veterans’ baseline dialysis date. Results Of 1,388 veterans, 27% received dialysis exclusively in VA, 47% in VA-outsourced settings, and 25% in dual settings. Overall, half (48%) were hospitalized and 12% died. In adjusted analysis, veterans in VA-outsourced settings incurred fewer hospitalizations and shorter hospital stays than users of VA due to favorable selection. Dual-system dialysis patients had lower one-year mortality than veterans receiving VA dialysis. Conclusions VA expenditures for “buying” outsourced dialysis are high and increasing relative to “making” dialysis treatment within its own system. Outcomes comparisons inform future make-or-buy decisions and suggest the need for VA to consider veterans’ access to care, long-term VA savings, and optimal patient outcomes in its placement decisions for dialysis services. PMID:23327632
Broers, Natascha J.H.; Martens, Remy J.H.; Cornelis, Tom; van der Sande, Frank M.; Diederen, Nanda M.P.; Hermans, Marc M.H.; Wirtz, Joris J.J.M.; Stifft, Frank; Konings, Constantijn J.A.M.; Dejagere, Tom; Canaud, Bernard; Wabel, Peter; Leunissen, Karel M.L.; Kooman, Jeroen P.
2017-01-01
Objectives Physical inactivity in end-stage renal disease (ESRD) patients is associated with increased mortality, and might be related to abnormalities in body composition (BC) and physical performance. It is uncertain to what extent starting dialysis influences the effects of ESRD on physical activity (PA). This study aimed to compare PA and physical performance between stage 5 chronic kidney disease (CKD-5) non-dialysis and dialysis patients, and healthy controls, to assess alterations in PA during the transition from CKD-5 non-dialysis to dialysis, and to relate PA to BC. Methods For the cross-sectional analyses 44 CKD-5 non-dialysis patients, 29 dialysis patients, and 20 healthy controls were included. PA was measured by the SenseWear™ pro3. Also, the walking speed and handgrip strength (HGS) were measured. BC was measured by the Body Composition Monitor©. Longitudinally, these parameters were assessed in 42 CKD-5 non-dialysis patients (who were also part of the cross-sectional analysis), before the start of dialysis and 6 months thereafter. Results PA was significantly lower in CKD-5 non-dialysis patients as compared to that in healthy controls but not as compared to that in dialysis patients. HGS was significantly lower in dialysis patients as compared to that in healthy controls. Walking speed was significantly lower in CKD-5 non-dialysis patients as compared to that in healthy controls but not as compared to that in dialysis patients. Six months after starting dialysis, activity related energy expenditure (AEE) and walking speed significantly increased. Conclusions PA is already lower in CKD-5 non-dialysis patients as compared to that in healthy controls and does not differ from that of dialysis patients. However, the transition phase from CKD-5 non-dialysis to dialysis is associated only with a modest improvement in AEE. PMID:28591752
The Two-Bag Method for Treatment of Diabetic Ketoacidosis in Adults.
Haas, Nathan L; Gianchandani, Roma Y; Gunnerson, Kyle J; Bassin, Benjamin S; Ganti, Arun; Hapner, Christopher; Boyd, Caryn; Cranford, James A; Whitmore, Sage P
2018-05-01
The "two-bag method" of management of diabetic ketoacidosis (DKA) allows for titration of dextrose delivery by adjusting the infusions of two i.v. fluid bags of varying dextrose concentrations while keeping fluid, electrolyte, and insulin infusion rates constant. We aimed to evaluate the feasibility and potential benefits of this strategy in adult emergency department (ED) patients with DKA. This is a before-and-after comparison of a protocol using the two-bag method operationalized in our adult ED in 2015. A retrospective electronic medical record search identified adult ED patients presenting with DKA from January 1, 2013 to June 30, 2016. Clinical and laboratory data, timing of medical therapies, and safety outcomes were collected and analyzed. Sixty-eight patients managed with the two-bag method (2B) and 107 patients managed with the one-bag method (1B) were identified. The 2B and 1B groups were similar in demographics and baseline metabolic derangements, though significantly more patients in the 2B group received care in a hybrid ED and intensive care unit setting (94.1% vs. 51.4%; p < 0.01). 2B patients experienced a shorter interval to first serum bicarbonate ≥ 18 mEq/L (13.4 vs. 20.0 h; p < 0.05), shorter duration of insulin infusion (14.1 vs. 21.8 h; p < 0.05), and fewer fluid bags were charged to the patient (5.2 vs. 29.7; p < 0.01). Frequency of any measured hypoglycemia or hypokalemia trended in favor of the 2B group (2.9% vs. 10.3%; p = 0.07; 16.2% vs. 27.1%; p = 0.09; respectively), though did not reach significance. The 2B method appears feasible for management of adult ED patients with DKA, and use was associated with earlier correction of acidosis, earlier discontinuation of insulin infusion, and fewer i.v. fluid bags charged than traditional 1B methods, while no safety concerns were observed. Copyright © 2018 Elsevier Inc. All rights reserved.
Liberek, Tomasz; Lichodziejewska-Niemierko, Monika; Knopinska-Posluszny, Wanda; Schaub, Thomas P; Kirchgessner, Judith; Passlick-Deetjen, Jutta; Rutkowski, Boleslaw
2002-01-01
In order to evaluate the biocompatibility profile of a newly designed peritoneal dialysis fluid (PDF), we evaluated peritoneal leukocyte (PMphi) cytokine release following overnight in vivo dwells using standard, lactate-buffered, single-chamber bag PDF (Lac-PDF) and purely bicarbonate-buffered, double-chamber bag PDF containing 34 (Bic-PDF) or 39 (Bic Hi-PDF) mmol/L bicarbonate. A randomized, open, crossover clinical trial with single weekly test dwells was performed in stable, long-term continuous ambulatory PD patients (n = 8). During 8-hour overnight dwells, PMphi were exposed to different PDF containing 1.5% glucose. After drainage, peritoneal cells were isolated and incubated with RPMI 1640 medium for 2 or 3 hours, with and without stimulation by lipopolysaccharide (LPS). Ex vivo release of tumor necrosis factor (TNF)-alpha and interleukin (IL)-6 was measured by specific ELISA technique. After pre-exposure to Lac-PDF, PMphi generated 242 +/- 279 pg TNFalpha/10(6) cells and 157 +/- 105 pg IL-6/10(6) cells. When pre-exposed to Bic-PDF and Bic Hi-PDF, TNFa and IL-6 production of PMphi was not significantly different from Lac-PDF. After LPS stimulation (100 ng/mL), PMD secretion of TNFalpha and IL-6 pre-exposed to three PDF revealed no significant differences between groups: TNFalpha was 2,864 +/- 1,216, 2,910 +/- 1,202, and 3,291 +/- 558 pg/10(6) cells after overnight dwells with Lac-PDF, Bic-PDF, and Bic Hi-PDF, respectively. Comparably, LPS-stimulated (100 pg/ mL) PMphi showed IL-6 secretion of 891 +/- 335, 1,380 +/- 1,149, and 1,442 +/- 966 pg/10(6) cells for Lac-PDF, Bic-PDF, and Bic Hi-PDF. After long-term overnight dwells, initial pH, the different buffers, and varying glucose degradation product levels of PDF do not strongly affect PMphi function with respect to cytokine release. The lack of significant differences between fluids may result from the complete dialysate equilibration achieved during the overnight intraperitoneal dwell.
Scialla, Julia J.; Liu, Jiannong; Crews, Deidra C.; Guo, Haifeng; Bandeen-Roche, Karen; Ephraim, Patti L.; Tangri, Navdeep; Sozio, Stephen M.; Shafi, Tariq; Miskulin, Dana C.; Michels, Wieneke M.; Jaar, Bernard G.; Wu, Albert W.; Powe, Neil R.; Boulware, L. Ebony
2014-01-01
The estimated glomerular filtration rate (eGFR) at dialysis initiation has been rising. Observational studies suggest harm, but may be confounded by unmeasured factors. As instrumental variable methods may be less biased we performed a retrospective cohort study of 310,932 patients starting dialysis between 2006 to 2008 and registered in the United States Renal Data System in order to describe geographic variation in eGFR at dialysis initiation and determine its association with mortality. Patients were grouped into 804 health service areas by zip code. Individual eGFR at dialysis initiation averaged 10.8 ml/min/1.73m2 but varied geographically. Only 11% of the variation in mean health service areas-level eGFR at dialysis initiation was accounted for by patient characteristics. We calculated demographic-adjusted mean eGFR at dialysis initiation in the health service areas using the 2006 and 2007 incident cohort as our instrument and estimated the association between individual eGFR at dialysis initiation and mortality in the 2008 incident cohort using the 2 stage residual inclusion method. Among 89,547 patients starting dialysis in 2008 with eGFR 5 to 20 ml/min/1.73m2, eGFR at initiation was not associated with mortality over a median of 15.5 months [hazard ratio 1.025 per 1 ml/min/1.73m2 for eGFR 5 to 14 ml/min/1.73m2; and 0.973 per 1 ml/min/1.73m2 for eGFR 14 to 20 ml/min/1.73m2]. Thus, there was no associated harm or benefit from early dialysis initiation in the United States. PMID:24786707
Photoacoustic measurements of red blood cell oxygen saturation in blood bags in situ
NASA Astrophysics Data System (ADS)
Pinto, Ruben N.; Bagga, Karan; Douplik, Alexandre; Acker, Jason P.; Kolios, Michael C.
2017-03-01
Red blood cell (RBC) transfusion is a critical component of the health care services. RBCs are stored in blood bags in hypothermic temperatures for a maximum of 6 weeks post donation. During this in vitro storage period, RBCs have been documented to undergo changes in structure and function due to mechanical and biochemical stress. Currently, there are no assessment methods that monitor the quality of RBCs within blood bags stored for transfusion. Conventional assessment methods require the extraction of samples, consequently voiding the sterility of the blood bags and potentially rendering them unfit for transfusions. It is hypothesized that photoacoustic (PA) technology can provide a rapid and non-invasive indication of RBC quality. In this study, a novel PA setup was developed for the acquisition of oxygen saturation (SO2) of two blood bags in situ. These measurements were taken throughout the lifespan of the blood bags (42 days) and compared against the clinical gold standard method of the blood gas analyzer (BGA). SO2 values of the blood bags increased monotonically throughout the storage period. A strong correlation between PA SO2 and BGA SO2 was found, however, PA values were on average 3.5% lower. Both techniques found the bags to increase by an SO2 of approximately 20%, and measured very similar rates of SO2 change. Future work will be focused on determining the cause of discrepancy between SO2 values acquired from PA versus BGA, as well as establishing links between the measured SO2 increase and other changes in RBC in situ.
NASA Astrophysics Data System (ADS)
Masrournia, Mahboube; Montazarolmahdi, Maliheh; Sani, Faramarz Aliasghari
2017-07-01
Determination of dextrose in peritoneal dialysis with a method based on silver nanoparticles (AgNPs) formation was investigated. In a green chemistry method, silver nanoparticles (AgNPs) were synthesized in the natural polymeric matrix of gelatin. The nanoparticles were characterized with UV-Vis spectroscopy and transmission electron microscopy (TEM). Absorbance signal of AgNPs could be applied to determine the various concentrations of dextrose solutions. Drop wise and ultrasonic methods were used and compared with each other. The dynamic range of methods with limit of detection and relative standard deviations were obtained. Results for real sample (peritoneal dialysis) were satisfied.
BAG3 promotes chondrosarcoma progression by upregulating the expression of β-catenin.
Shi, Huijuan; Chen, Wenfang; Dong, Yu; Lu, Xiaofang; Zhang, Wenhui; Wang, Liantang
2018-04-01
To investigate the roles of B‑cell lymphoma‑2 associated athanogene 3 (BAG3) in human chondrosarcoma and the potential mechanisms, the expression levels of BAG3 were detected in the present study, and the associations between BAG3 and clinical pathological parameters, clinical stage as well as the survival of patients were analyzed. The present study detected BAG3 mRNA and protein expression in the normal cartilage cell line HC‑a and in SW1353 chondrosarcoma cells by reverse transcription‑quantitative polymerase chain reaction and western blot analysis. The BAG3 protein expression in 59 cases of chondrosarcoma, 30 patients with endogenous chondroma and 8 cases of normal cartilage was semi-quantitatively analyzed using the immunohistochemical method. In addition, the BAG3 protein expression level, the clinical pathological parameters, clinical stage and the survival time of patients with chondrosarcoma were analyzed. The plasmid transfection method was employed to upregulate the expression BAG3 and small RNA interference to downregulate the expression of BAG3 in SW1353 cells. The expression levels of BAG3 protein and mRNA were significantly increased in the chondrosarcoma cell line when compared with the normal cartilage cell line. The immunohistochemistry results indicated that BAG3 protein was overexpressed in the tissue of human chondrosarcoma. Statistical analysis showed that the expression level of BAG3 was significantly increased in the different Enneking staging of patients with chondrosarcoma and Tumor staging, and there were no statistical differences in age, gender, histological classification and tumor size. In the in vitro experiments, the data revealed that BAG3 significantly promoted chondrosarcoma cell proliferation, colony‑formation, migration and invasion; however, it inhibited chondrosarcoma cell apoptosis. It was observed that BAG3 upregulated β‑catenin expression at the mRNA and protein levels. In addition, BAG3 induced the expression of runt‑related transcription factor 2 (RUNX2) in chondrosarcoma cells by upregulating β‑catenin. These clinical analyses revealed a positive association between β‑catenin and BAG3 in chondrosarcoma tumors. BAG3 was significantly increased in chondrosarcoma cells and tissues compared with the normal cartilage cells, tissue and cartilage benign tumors. Thus, BAG3 may serve as an oncogene in the development of chondrosarcoma via the induction of RUNX2 expression. The results of the present study contribute to further research on the biological development of chondrosarcoma.
Driver air bag effectiveness by severity of the crash.
Segui-Gomez, M
2000-01-01
OBJECTIVES: This analysis provided effectiveness estimates of the driver-side air bag while controlling for severity of the crash and other potential confounders. METHODS: Data were from the National Automotive Sampling System (1993-1996). Injury severity was described on the basis of the Abbreviated Injury Scale, Injury Severity Score, Functional Capacity Index, and survival. Ordinal, linear, and logistic multivariate regression methods were used. RESULTS: Air bag deployment in frontal or near-frontal crashes decreases the probability of having severe and fatal injuries (e.g., Abbreviated Injury Scale score of 4-6), including those causing a long-lasting high degree of functional limitation. However, air bag deployment in low-severity crashes increases the probability that a driver (particularly a woman) will sustain injuries of Abbreviated Injury Scale level 1 to 3. Air bag deployment exerts a net injurious effect in low-severity crashes and a net protective effect in high-severity crashes. The level of crash severity at which air bags are protective is higher for female than for male drivers. CONCLUSIONS: Air bag improvement should minimize the injuries induced by their deployment. One possibility is to raise their deployment level so that they deploy only in more severe crashes. PMID:11029991
Antibacterial and remineralization effects of orthodontic bonding agents containing bioactive glass
Kim, Dong-Hyun; Song, Chang Weon; Yoon, Seog-Young; Kim, Se-Yeon; Na, Hee Sam; Chung, Jin
2018-01-01
Objective The aim of this study was to evaluate the mechanical and biological properties of orthodontic bonding agents containing silver- or zinc-doped bioactive glass (BAG) and determine the antibacterial and remineralization effects of these agents. Methods BAG was synthesized using the alkali-mediated solgel method. Orthodontic bonding agents containing BAG were prepared by mixing BAG with flowable resin. Transbond™ XT (TXT) and Charmfil™ Flow (CF) were used as controls. Ion release, cytotoxicity, antibacterial properties, the shear bond strength, and the adhesive remnant index were evaluated. To assess the remineralization properties of BAG, micro-computed tomography was performed after pH cycling. Results The BAG-containing bonding agents showed no noticeable cytotoxicity and suppressed bacterial growth. When these bonding agents were used, demineralization after pH cycling began approximately 200 to 300 µm away from the bracket. On the other hand, when CF and TXT were used, all surfaces that were not covered by the adhesive were demineralized after pH cycling. Conclusions Our findings suggest that orthodontic bonding agents containing silver- or zinc-doped BAG have stronger antibacterial and remineralization effects compared with conventional orthodontic adhesives; thus, they are suitable for use in orthodontic practice. PMID:29732302
Asymmetric bagging and feature selection for activities prediction of drug molecules.
Li, Guo-Zheng; Meng, Hao-Hua; Lu, Wen-Cong; Yang, Jack Y; Yang, Mary Qu
2008-05-28
Activities of drug molecules can be predicted by QSAR (quantitative structure activity relationship) models, which overcomes the disadvantages of high cost and long cycle by employing the traditional experimental method. With the fact that the number of drug molecules with positive activity is rather fewer than that of negatives, it is important to predict molecular activities considering such an unbalanced situation. Here, asymmetric bagging and feature selection are introduced into the problem and asymmetric bagging of support vector machines (asBagging) is proposed on predicting drug activities to treat the unbalanced problem. At the same time, the features extracted from the structures of drug molecules affect prediction accuracy of QSAR models. Therefore, a novel algorithm named PRIFEAB is proposed, which applies an embedded feature selection method to remove redundant and irrelevant features for asBagging. Numerical experimental results on a data set of molecular activities show that asBagging improve the AUC and sensitivity values of molecular activities and PRIFEAB with feature selection further helps to improve the prediction ability. Asymmetric bagging can help to improve prediction accuracy of activities of drug molecules, which can be furthermore improved by performing feature selection to select relevant features from the drug molecules data sets.
NASA Astrophysics Data System (ADS)
Hoffmeister, Cristiane RD; Durli, Taís L.; Schaffazick, Scheila R.; Raffin, Renata P.; Bender, Eduardo A.; Beck, Ruy CR; Pohlmann, Adriana R.; Guterres, Sílvia S.
2012-05-01
The aim of the present study was to develop a transdermal system for controlled delivery of melatonin combining three strategies: nanoencapsulation of melatonin, drying of melatonin-loaded nanocapsules, and incorporation of nanocapsules in a hydrophilic gel. Nanocapsules were prepared by interfacial deposition of the polymer and were spray-dried using water-soluble excipients. In vitro drug release profiles were evaluated by the dialysis bag method, and skin permeation studies were carried out using Franz cells with porcine skin as the membrane. The use of 10% ( w/ v) water-soluble excipients (lactose or maltodextrin) as spray-drying adjuvants furnished redispersible powders (redispersibility index approximately 1.0) suitable for incorporation into hydrogels. All formulations showed a better controlled in vitro release of melatonin compared with the melatonin solution. The best controlled release results were achieved with hydrogels prepared with dried nanocapsules (hydrogels > redispersed dried nanocapsules > nanocapsule suspension > melatonin solution). The skin permeation studies demonstrated a significant modulation of the transdermal melatonin permeation for hydrogels prepared with redispersible nanocapsules. In this way, the additive effect of the different approaches used in this study (nanoencapsulation, spray-drying, and preparation of semisolid dosage forms) allows not only the control of melatonin release, but also transdermal permeation.
Carbamazepine parenteral nanoemulsions prepared by spontaneous emulsification process.
Kelmann, Regina G; Kuminek, Gislaine; Teixeira, Helder F; Koester, Letícia S
2007-09-05
Carbamazepine (CBZ), a widely used anticonvulsant drug, is a poorly soluble drug with no parenteral treatment available for patients. This study was aimed at developing a nanoemulsion for CBZ intravenous delivery. The spontaneous emulsification method was used to prepare different formulations containing 2mg/mL CBZ. Likewise, a 2(2) full factorial experimental design was applied to study the influence of two independent variables (type of oil and type of lipophilic emulsifier) on emulsion physicochemical characteristics. The nanoemulsions were evaluated concerning droplet size, zeta potential, viscosity, drug content and association to oily phase. The formulation, which presented the best characteristics required for intravenous administration was selected and refined with respect to the lipophilic emulsifier content (increase from 5% to 6% of soy lecithin). This formulation was characterized and kept its properties in a satisfactory range over the evaluated period (3 months), i.e. droplet size around 150 nm, drug content around 95% and zeta potential around -40 mV. The transmission electron microscopy revealed emulsion droplets almost spherical in shape with an amorphous core, whereas the in vitro release profile assessed by dialysis bags demonstrated a release kinetics square root time dependent, with 95% of ca. having been released within 11h.
Multiple-instance ensemble learning for hyperspectral images
NASA Astrophysics Data System (ADS)
Ergul, Ugur; Bilgin, Gokhan
2017-10-01
An ensemble framework for multiple-instance (MI) learning (MIL) is introduced for use in hyperspectral images (HSIs) by inspiring the bagging (bootstrap aggregation) method in ensemble learning. Ensemble-based bagging is performed by a small percentage of training samples, and MI bags are formed by a local windowing process with variable window sizes on selected instances. In addition to bootstrap aggregation, random subspace is another method used to diversify base classifiers. The proposed method is implemented using four MIL classification algorithms. The classifier model learning phase is carried out with MI bags, and the estimation phase is performed over single-test instances. In the experimental part of the study, two different HSIs that have ground-truth information are used, and comparative results are demonstrated with state-of-the-art classification methods. In general, the MI ensemble approach produces more compact results in terms of both diversity and error compared to equipollent non-MIL algorithms.
Prnjavorac, Besim; Irejiz, Nedzada; Kurbasic, Zahid; Krajina, Katarina; Deljkic, Amina; Sinanovic, Albina; Fejzic, Jasmin
2015-04-01
Appropriate vitamin D turnover is essential for many physiological function. Knowledge of it's function was improved in last two decades with enlargement of scientific confirmation and understanding of overall importance. In addition to classical (skeletal) roles of vitamin D, many other function (no classical), out of bone and calcium-phosphate metabolism, are well defined today. To analyze vitamin D level in the blood in dialysis and pre dialysis patients and evaluate efficacy of supplementation therapy with vitamin D supplements. Vitamin D3 level in form of 25-hydroxivitamin D3 was measured in dialysis and pre dialysis patients, using combination of enzyme immunoassay competition method with final fluorescent detection (ELFA). Parathormone was measured by ELISA method. Other parameters were measured by colorimetric methods. Statistical analysis was done by nonparametric methods, because of dispersion of results of Vitamin D and parathormone. In group of dialysis patients 38 were analyzed. Among them 35 (92%) presented vitamin D deficiency, whether they took supplementation or not. In only 3 patients vitamin D deficiency was not so severe. Vitamin D form were evaluated in 42 pre dialysis patients. Out of all 19 patients (45 %) have satisfied level, more than 30 ng/ml. Moderate deficiency have 16 patients (38%), 5 of all (12%) have severe deficiency, and two patients (5%) have very severe deficiency, less than 5 ng/ml. Parathormone was within normal range (9.5-75 pg/mL) in 13 patients (34 %), below normal range (2 %) in one subject, and in above normal range in 24 (63 %). Vitamin D3 deficiency was registered in most hemodialysis patients; nevertheless supplemental therapy was given regularly or not. It is to be considered more appropriate supplementation of Vitamin D3 for dialyzed patients as well as for pre dialysis ones. In pre dialysis patient moderate deficiency is shown in half of patients but sever in only two.
Vroblesky, Don A.; Petkewich, Matthew D.; Campbell, Ted R.
2002-01-01
Field tests were performed on two types of diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. Nylon-screen samplers and dialysis samplers were tested for the collection of arsenic, calcium, chloride, iron, manganese, sulfate, and dissolved oxygen. The investigations were conducted at the Naval Industrial Reserve Ordnance Plant (NIROP), Fridley, Minnesota, and at the Naval Air Station Fort Worth Joint Reserve Base (NAS Fort Worth JRB), Texas. Data indicate that, in general, nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water that correspond to concentrations obtained by low-flow sampling. Diffusion samplers offer a potentially time-saving approach to well sampling. Particular care must be taken, however, when sampling for iron and other metals, because of the potential for iron precipitation by oxygenation and when dealing with chemically stratified sampling intervals. Simple nylon-screen jar samplers buried beneath creekbed sediment appear to be effective tools for locating discharge zones of arsenic contaminated ground water. Although the LDPE samplers have proven to be inexpensive and simple to use in wells, they are limited by their inability to provide a representative sample of ionic solutes. The success of nylon-screen samplers in sediment studies suggests that these simple samplers may be useful for collecting water samples for inorganic constituents in wells. Results using dialysis bags deployed in wells suggest that these types of samplers have the potential to provide a representative sample of both VOCs and ionic solutes from ground water (Kaplan and others, 1991; Theodore A. Ehlke, U.S. Geological Survey, written commun., 2001). The purpose of this report is to provide results of field tests investigating the potential to use diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. The investigations were performed at NIROP, Fridley, Minn. (fig. 1) and at NAS Fort Worth JRB, Texas (fig. 2). Two types of samplers were tested. One type was a nylon-screen sampler, which consisted of a 30-mL jar filled with deionized water, with its opening covered by a nylon screen. The second type was a dialysis sampler that consisted of a tube of dialysis membrane filled with deionized water. The nylon-screen samplers were deployed in wells at NIROP Fridley and NAS Fort Worth JRB and beneath the ground-water/surface water interface of a stream at NAS Fort Worth JRB. The dialysis samplers were deployed only in wells at NAS Fort Worth JRB.
Wright, Linda S; Wilson, Linda
2015-01-01
Previous research has demonstrated improved outcomes for patients on dialysis who have better quality of life and self-efficacy, but has focused almost exclusively on those receiving hemodialysis. The goal of this study was to describe the quality of life and self-efficacy of patients receiving incenter hemodialysis versus those receiving a home dialysis modality (hemodialysis or peritoneal dialysis). The study utilized a correlational cross-sectional design and quota sampling methods. Participants were recruited from outpatient dialysis facilities and included 77 community dwelling adult patients who had been on dialysis for at least six months. Quality of life was measured using the Kidney Disease Quality of Life instrument, and self-efficacy was measured using the Strategies Used by People to Promote Health instrument. Findings suggest equal outcomes between treatment groups, with no contraindication to the use of home therapies.
Inspection In Overhead Spaces Containing Asbestos
NASA Technical Reports Server (NTRS)
Bell, Jacque; Hartwick, George; Hutcherson, Jerry
1989-01-01
Procedure for inspection in spaces above dropped ceilings that contain asbestos saves time and effort without sacrificing safety. With new method, only items of safety equipment needed are glove bag, storage bag, and roll of adhesive tape. Inspector tapes glove bag tightly to support grid around ceiling tile to be removed. With hands in gloves inspector lifts tile gently and places it aside. Extending head and shoulders into bag, inspector examines space above ceiling with help of flashlight.
Khuu, H M; Cowley, H; David-Ocampo, V; Carter, C S; Kasten-Sportes, C; Wayne, A S; Solomon, S R; Bishop, M R; Childs, R M; Read, E J
2002-01-01
Container integrity is critical for maintaining sterility of cryopreserved cellular therapy products. We investigated a series of catastrophic bag failures, first noticed in early 2001. Process records were reviewed for all PBPC and lymphocyte products cryopreserved in bags from January 2000 through April 2002. Patient charts were also reviewed. One thousand two hundred and four bags were removed from storage for infusion to 261 patients. All products had been cryopreserved in Cryocyte poly(ethylene co-vinyl acetate) (EVA) bags in either 10% DMSO or 5% DMSO and 6% pentastarch. Product volumes were 25-75 mL, and bags were stored with overwrap bags in a liquid nitrogen tank. From January 2000 to April 2001, failure occurred in 10 of 599 (1.7%) bags. From May 2001 to April 2002, 58 of 605 (9.6%) bags failed, typically with extensive fractures that were visible before thaw. Of the 58 that failed, 24 were salvaged by aseptic methods and infused to patients under antibiotic coverage; 10 of those 24 (42%) had positive bacterial cultures. Bag failures were not related to product type, cryoprotectant solution, liquid versus vapor storage, or freezer location. Failures were linked to use of four Cryocyte bag lots manufactured in 2000 and 2001. After replacing these lots with a 1999 Cryocyte lot and with KryoSafe polyfluoroethylene polyfluoropropylene (FEP) bags, no more failures occurred in 75 and 102 bags, respectively, thawed through April 2002. High rates of bag failure were associated with four Cryocyte bag lots. No serious adverse patient effects occurred, but bag failures led to microbial contamination, increased product preparation time, increased antibiotic use, and increased resource expenditure to replace products.
Recovery of renal function in dialysis patients
Agraharkar, Mahendra; Nair, Vasudevan; Patlovany, Matthew
2003-01-01
Background Although recovery of renal functions in dialysis dependent patients is estimated to be greater than 1%, there are no indicators that actually suggest such revival of renal function. Residual renal function in dialysis patients is unreliable and seldom followed. Therefore renal recovery (RR) in dialysis dependent patients may remain unnoticed. We present a group of dialysis dependent patients who regained their renal functions. The aim of this project is to determine any indicators that may identify the recovery of renal functions in dialysis dependent patients. Methods All the discharges from the chronic dialysis facilities were identified. Among these discharges deaths, transplants, voluntary withdrawals and transfers either to another modality or another dialysis facility were excluded in order to isolate the patients with RR. The dialysis flow sheets and medical records of these patients were subsequently reviewed. Results Eight patients with a mean age of 53.8 ± 6.7 years (± SEM) were found to have RR. Dialysis was initiated due to uremic symptoms in 6 patients and fluid overload in the remaining two. The patients remained dialysis dependent for 11.1 ± 4.2 months. All these patients had good urine output and 7 had symptoms related to dialysis. Their mean pre-initiation creatinine and BUN levels were 5.21 ± 0.6 mg/dl and 72.12 ± 11.12 mg/dl, respectively. Upon discontinuation, they remained dialysis free for 19.75 ± 5.97 months. The mean creatinine and BUN levels after cessation of dialysis were 2.85 ± 0.57 mg/dl and 29.62 ± 5.26 mg/dl, respectively, while the mean creatinine clearance calculated by 24-hour urine collection was 29.75 ± 4.78 ml/min. One patient died due to HIV complications. One patient resumed dialysis after nine months. Remaining continue to enjoy a dialysis free life. Conclusion RR must be considered in patients with good urine output and unresolved acute renal failure. Dialysis intolerance may be an indicator of RR among such patients. PMID:14563216
Health-related quality of life and all-cause mortality in patients with diabetes on dialysis
2012-01-01
Background This study tests the hypotheses that health-related quality of life (HRQOL) in prevalent dialysis patients with diabetes is lower than in dialysis patients without diabetes, and is at least as poor as diabetic patients with another severe complication, i.e. foot ulcers. This study also explores the mortality risk associated with diabetes in dialysis patients. Methods HRQOL was assessed using the Short Form-36 Health Survey (SF-36), in a cross-sectional study of 301 prevalent dialysis patients (26% with diabetes), and compared with diabetic patients not on dialysis (n = 221), diabetic patients with foot ulcers (n = 127), and a sample of the general population (n = 5903). Mortality risk was assessed using a Kaplan-Meier plot and Cox proportional hazards analysis. Results Self-assessed vitality, general and mental health, and physical function were significantly lower in dialysis patients with diabetes than in those without. Vitality (p = 0.011) and general health (p <0.001) was impaired in diabetic patients receiving dialysis compared to diabetic patients with foot ulcers, but other subscales did not differ. Diabetes was a significant predictor for mortality in dialysis patients, with a hazard ratio (HR) of 1.6 (95% CI 1.0-2.5) after adjustment for age, dialysis vintage and coronary artery disease. Mental aspects of HRQOL were an independent predictor of mortality in diabetic patients receiving dialysis after adjusting for age and dialysis vintage (HR 2.2, 95% CI 1.0-5.0). Conclusions Physical aspects of HRQOL were perceived very low in dialysis patients with diabetes, and lower than in other dialysis patients and diabetic patients without dialysis. Mental aspects predicted mortality in dialysis patients with diabetes. Increased awareness and measures to assist physical function impairment may be particularly important in diabetes patients on dialysis. PMID:22863310
Madureira, Ana Raquel; Campos, Débora A; Oliveira, Ana; Sarmento, Bruno; Pintado, Maria Manuela; Gomes, Ana Maria
2016-03-01
The evaluation of the digestion effects on bioactive solid lipid nanoparticles (SLN) was performed. For this purpose, witepsol and carnauba SLN loaded with rosmarinic acid (RA) were exposed to the simulated gastrointestinal tract (GIT) conditions prevailing in stomach and small intestine. The simulation of intestinal epithelium was made with a dialysis bag and intestinal cell culture lines. Changes on SLN physical properties, RA release and absorption profiles were followed at each step. Combination of digestion pH and enzymes showed a significant effect upon SLN physical properties. Zeta potential values increased at stomach conditions and decreased at small intestine simulation. Also, at intestine, SLN increased their sizes and released 40-60% of RA, maintaining its initial antioxidant activity values. Sustained release of 40% of RA from SLN was also observed in dialysis tube. At CaCo-2 cell line, both types of SLN showed similar absorbed RA % (ca. 30%). Nevertheless, in CaCo-2/HT29x mix cell lines, for carnauba SLN a lower adsorption RA % was observed than for witepsol SLN. Solid lipid nanoparticles protected RA bioactivity (in terms of antioxidant activity) until reaching the intestine. A controlled release of RA from SLN was achieved and a significant absorption was observed at intestinal cells. Overall, SLN produced with witepsol showed a higher stability than carnauba SLN. Copyright © 2015 Elsevier B.V. All rights reserved.
Krischock, Leah; Kennedy, Sean E; Hayen, Andrew
2017-12-01
The aim of the study is to improve the understanding of outcomes and complications of dialysis in adolescents and young adults (AYA) to inform decisions about dialysis modality in this patient population. Registry data on Australian AYA aged 13 to 20 years who commenced dialysis between 1/1/2000 and 31/12/2013 were retrieved from the Australia and New Zealand Dialysis and Transplantation Registry and analyzed to determine associations between demographic characteristics, dialysis modality and outcomes. During the study period 300 AYA commenced dialysis at a median age of 17.2 years (IQR 15.6 to 18.6 years). Haemodialysis (HD) was the initial dialysis modality in 201 patients (67%). No significant differences between AYA receiving HD and peritoneal dialysis (PD) were noted in patient gender, age, race, primary renal disease, treating centre type, remoteness of residential area, lateness of referral or period of study. Mean haemoglobin levels were lower in the HD group (P = 0.005) and significantly fewer HD patients attended school full time compared to patients managed on PD (P = 0.002 first year; P = 0.05 second year). Dialysis modality choice does not appear to be influenced by patient characteristics nor dialysis outcomes. Future research is required to examine the reasons that HD is preferred over PD and to determine the optimal method of dialysis for this age group. © 2016 Asian Pacific Society of Nephrology.
Schroeder, Alan R; Newman, Thomas B; Wasserman, Richard C; Finch, Stacia A; Pantell, Robert H
2005-10-01
The optimal method of urine collection in febrile infants is debatable; catheterization, considered more accurate, is technically difficult and invasive. To determine predictors of urethral catheterization in febrile infants and to compare bag and catheterized urine test performance characteristics. Prospective analysis of infants enrolled in the Pediatric Research in Office Settings' Febrile Infant Study. A total of 219 practices from within the Pediatric Research in Office Settings' network, including 44 states, the District of Columbia, and Puerto Rico. A total of 3066 infants aged 0 to 3 months with temperatures of 38 degrees C or higher. We calculated adjusted odds ratios for predictors of catheterization. Diagnostic test characteristics were compared between bag and catheterization. Urinary tract infection was defined as pure growth of 100 000 CFU/mL or more (bag) and 20 000 CFU/mL or more (catheterization). Seventy percent of urine samples were obtained by catheterization. Predictors of catheterization included female sex, practitioner older than 40 years, Medicaid, Hispanic ethnicity, nighttime evaluation, and severe dehydration. For leukocyte esterase levels, bag specimens demonstrated no difference in sensitivity but somewhat lower specificity (84% [bag] vs 94% [catheterization], P<.001) and a lower area under the receiver operating characteristic curve for white blood cells (0.71 [bag] vs 0.86 [catheterization], P = .01). Infection rates were similar in bag and catheterized specimens (8.5% vs 10.8%). Ambiguous cultures were more common in bag specimens (7.4% vs 2.7%, P<.001), but 21 catheterized specimens are needed to avoid each ambiguous bag result. Most practitioners obtain urine from febrile infants via catheterization, but choice of method is not related to the risk of urinary tract infection. Although both urine cultures and urinalyses are more accurate in catheterized specimens, the magnitude of difference is small but should be factored into clinical decision making.
Abhyankar, Swapna; Demner-Fushman, Dina; Callaghan, Fiona M; McDonald, Clement J
2014-01-01
Objective To develop a generalizable method for identifying patient cohorts from electronic health record (EHR) data—in this case, patients having dialysis—that uses simple information retrieval (IR) tools. Methods We used the coded data and clinical notes from the 24 506 adult patients in the Multiparameter Intelligent Monitoring in Intensive Care database to identify patients who had dialysis. We used SQL queries to search the procedure, diagnosis, and coded nursing observations tables based on ICD-9 and local codes. We used a domain-specific search engine to find clinical notes containing terms related to dialysis. We manually validated the available records for a 10% random sample of patients who potentially had dialysis and a random sample of 200 patients who were not identified as having dialysis based on any of the sources. Results We identified 1844 patients that potentially had dialysis: 1481 from the three coded sources and 1624 from the clinical notes. Precision for identifying dialysis patients based on available data was estimated to be 78.4% (95% CI 71.9% to 84.2%) and recall was 100% (95% CI 86% to 100%). Conclusions Combining structured EHR data with information from clinical notes using simple queries increases the utility of both types of data for cohort identification. Patients identified by more than one source are more likely to meet the inclusion criteria; however, including patients found in any of the sources increases recall. This method is attractive because it is available to researchers with access to EHR data and off-the-shelf IR tools. PMID:24384230
Shephard, Roy J
2017-03-01
The Douglas bag technique is reviewed as one in a series of articles looking at historical insights into measurement of whole body metabolic rate. Consideration of all articles looking at Douglas bag technique and chemical gas analysis has here focused on the growing appreciation of errors in measuring expired volumes and gas composition, and subjective reactions to airflow resistance and dead space. Multiple small sources of error have been identified and appropriate remedies proposed over a century of use of the methodology. Changes in the bag lining have limited gas diffusion, laboratories conducting gas analyses have undergone validation, and WHO guidelines on airflow resistance have minimized reactive effects. One remaining difficulty is a contamination of expirate by dead space air, minimized by keeping the dead space <70 mL. Care must also be taken to ensure a steady state, and formal validation of the Douglas bag method still needs to be carried out. We may conclude that the Douglas bag method has helped to define key concepts in exercise physiology. Although now superceded in many applications, the errors in a meticulously completed measurement are sufficiently low to warrant retention of the Douglas bag as the gold standard when evaluating newer open-circuit methodology.
2012-01-01
Background This study examines the patients' need for information and guidance in the selection of dialysis modality, and in establishing and practicing home dialysis. The study focuses on patients' experiences living with home dialysis, how they master the treatment, and their views on how to optimize communication with health services and the potential of telemedicine. Methods We used an inductive research strategy and conducted semi-structured interviews with eleven patients established in home dialysis. Our focus was the patients' experiences with home dialysis, and our theoretical reference was patients' empowerment through telemedicine solutions. Three informants had home haemodialysis (HHD); eight had peritoneal dialysis (PD), of which three had automated peritoneal dialysis (APD); and five had continuous ambulatory peritoneal dialysis (CAPD). The material comprises all PD-patients in the catchment area capable of being interviewed, and all known HHD-users in Norway at that time. Results All of the interviewees were satisfied with their choice of home dialysis, and many experienced a normalization of daily life, less dominated by disease. They exhibited considerable self-management skills and did not perceive themselves as ill, but still required very close contact with the hospital staff for communication and follow-up. When choosing a dialysis modality, other patients' experiences were often more influential than advice from specialists. Information concerning the possibility of having HHD, including knowledge of how to access it, was not easily available. Especially those with dialysis machines, both APD and HHD, saw a potential for telemedicine solutions. Conclusions As home dialysis may contribute to a normalization of life less dominated by disease, the treatment should be organized so that the potential for home dialysis can be fully exploited. Pre-dialysis information should be unbiased and include access to other patients' experiences. Telemedicine may potentially facilitate a communication-based follow-up and improve safety within the home setting, making it easier to choose and live with home dialysis. PMID:22429705
Xu, Xiaohui Sophia; Rose, Anne; Demers, Roger; Eley, Timothy; Ryan, John; Stouffer, Bruce; Cojocaru, Laura; Arnold, Mark
2014-01-01
The determination of drug-protein binding is important in the pharmaceutical development process because of the impact of protein binding on both the pharmacokinetics and pharmacodynamics of drugs. Equilibrium dialysis is the preferred method to measure the free drug fraction because it is considered to be more accurate. The throughput of equilibrium dialysis has recently been improved by implementing a 96-well format plate. Results/methodology: This manuscript illustrates the successful application of a 96-well rapid equilibrium dialysis (RED) device in the determination of atazanavir plasma-protein binding. This RED method of measuring free fraction was successfully validated and then applied to the analysis of clinical plasma samples taken from HIV-infected pregnant women administered atazanavir. Combined with LC-MS/MS detection, the 96-well format equilibrium dialysis device was suitable for measuring the free and bound concentration of pharmaceutical molecules in a high-throughput mode.
Continuing education: online monitoring of haemodialysis dose.
Vartia, Aarne
2018-01-25
Kt/V urea reflects the efficacy of haemodialysis scaled to patient size (urea distribution volume). The guidelines recommend monthly Kt/V measurements based on blood samples. Modern haemodialysis machines are equipped with accessories monitoring the dose online at every session without extra costs, blood samples and computers. To describe the principles, devices, benefits and shortcomings of online monitoring of haemodialysis dose. A critical literature overview and discussion. UV absorbance methods measure Kt/V, ionic dialysance Kt (product of clearance and treatment time; cleared volume without scaling). Both are easy and useful methods, but comparison is difficult due to problems in scaling of the dialysis dose to the patient's size. The best dose estimation method is the one which predicts the quality of life and survival most accurately. There is some evidence on the predictive value of ionic dialysance Kt, but more documentation is required on the UV method. Online monitoring is a useful tool in everyday quality assurance, but blood samples are still required for more accurate kinetic modelling. After reading this article the reader should be able to: Understand the elements of the Kt/V equation for dialysis dose. Compare and contrast different methods of measurement of dialysis dose. Reflect on the importance of adequate dialysis dose for patient survival and life quality. © 2018 European Dialysis and Transplant Nurses Association/European Renal Care Association.
Identification of control parameters for the sulfur gas storability with bag sampling methods
USDA-ARS?s Scientific Manuscript database
Air samples containing sulfur compounds are often collected and stored in sample bags prior to analyses. The storage stability of six gaseous sulfur compounds (H2S, CH3SH, DMS, CS2, DMDS and SO2) was compared between two different bag materials (polyvinyl fluoride (PVF) and polyester aluminum (PEA))...
Biofiltration: an effective and simple method to reduce dialysis time.
Mingardi, G; Massazza, M; Viganò, G; Mecca, G
1986-12-01
Biofiltration: an effective and simple method to reduce dialysis time. Six stable anuric patients, on maintenance hemodialysis, were treated for 10 weeks with a parallel flow 1 m2 cuprophan filter, for 20 weeks with a parallel flow 1.2 m2 polyacrylonitrile filter using the biofiltration (BF) technique and again 10 weeks with the cuprophan filter. Usual monitors were used, without automatic control of ultrafiltration. Biochemical and hematological profile, urea kinetic parameters, incidence of hypotensive episodes, body weight and blood pressure did not change throughout the study. We conclude that three hours of BF, at least for 20 weeks, are as effective and well tolerated as four hours standard hemodialysis and could be of value in reducing dialysis time, to permit better utilization of dialysis beds.
NASA Astrophysics Data System (ADS)
Bohrey, Sarvesh; Chourasiya, Vibha; Pandey, Archna
2016-03-01
Nanoparticles formulated from biodegradable polymers like poly(lactic-co-glycolic acid) (PLGA) are being extensively investigated as drug delivery systems due to their two important properties such as biocompatibility and controlled drug release characteristics. The aim of this work to formulated diazepam loaded PLGA nanoparticles by using emulsion solvent evaporation technique. Polyvinyl alcohol (PVA) is used as stabilizing agent. Diazepam is a benzodiazepine derivative drug, and widely used as an anticonvulsant in the treatment of various types of epilepsy, insomnia and anxiety. This work investigates the effects of some preparation variables on the size and shape of nanoparticles prepared by emulsion solvent evaporation method. These nanoparticles were characterized by photon correlation spectroscopy (PCS), transmission electron microscopy (TEM). Zeta potential study was also performed to understand the surface charge of nanoparticles. The drug release from drug loaded nanoparticles was studied by dialysis bag method and the in vitro drug release data was also studied by various kinetic models. The results show that sonication time, polymer content, surfactant concentration, ratio of organic to aqueous phase volume, and the amount of drug have an important effect on the size of nanoparticles. Hopefully we produced spherical shape Diazepam loaded PLGA nanoparticles with a size range under 250 nm with zeta potential -23.3 mV. The in vitro drug release analysis shows sustained release of drug from nanoparticles and follow Korsmeyer-Peppas model.
Range bagging: a new method for ecological niche modelling from presence-only data
Drake, John M.
2015-01-01
The ecological niche is the set of environments in which a population of a species can persist without introduction of individuals from other locations. A good mathematical or computational representation of the niche is a prerequisite to addressing many questions in ecology, biogeography, evolutionary biology and conservation. A particularly challenging question for ecological niche modelling is the problem of presence-only modelling. That is, can an ecological niche be identified from records drawn only from the set of niche environments without records from non-niche environments for comparison? Here, I introduce a new method for ecological niche modelling from presence-only data called range bagging. Range bagging draws on the concept of a species' environmental range, but was inspired by the empirical performance of ensemble learning algorithms in other areas of ecological research. This paper extends the concept of environmental range to multiple dimensions and shows that range bagging is computationally feasible even when the number of environmental dimensions is large. The target of the range bagging base learner is an environmental tolerance of the species in a projection of its niche and is therefore an ecologically interpretable property of a species' biological requirements. The computational complexity of range bagging is linear in the number of examples, which compares favourably with the main alternative, Qhull. In conclusion, range bagging appears to be a reasonable choice for niche modelling in applications in which a presence-only method is desired and may provide a solution to problems in other disciplines where one-class classification is required, such as outlier detection and concept learning. PMID:25948612
Range bagging: a new method for ecological niche modelling from presence-only data.
Drake, John M
2015-06-06
The ecological niche is the set of environments in which a population of a species can persist without introduction of individuals from other locations. A good mathematical or computational representation of the niche is a prerequisite to addressing many questions in ecology, biogeography, evolutionary biology and conservation. A particularly challenging question for ecological niche modelling is the problem of presence-only modelling. That is, can an ecological niche be identified from records drawn only from the set of niche environments without records from non-niche environments for comparison? Here, I introduce a new method for ecological niche modelling from presence-only data called range bagging. Range bagging draws on the concept of a species' environmental range, but was inspired by the empirical performance of ensemble learning algorithms in other areas of ecological research. This paper extends the concept of environmental range to multiple dimensions and shows that range bagging is computationally feasible even when the number of environmental dimensions is large. The target of the range bagging base learner is an environmental tolerance of the species in a projection of its niche and is therefore an ecologically interpretable property of a species' biological requirements. The computational complexity of range bagging is linear in the number of examples, which compares favourably with the main alternative, Qhull. In conclusion, range bagging appears to be a reasonable choice for niche modelling in applications in which a presence-only method is desired and may provide a solution to problems in other disciplines where one-class classification is required, such as outlier detection and concept learning.
Patient perspectives on informed decision-making surrounding dialysis initiation
Song, Mi-Kyung; Lin, Feng-Chang; Gilet, Constance A.; Arnold, Robert M.; Bridgman, Jessica C.; Ward, Sandra E.
2013-01-01
Background Careful patient–clinician shared decision-making about dialysis initiation has been promoted, but few studies have addressed patient perspectives on the extent of information provided and how decisions to start dialysis are made. Methods Ninety-nine maintenance dialysis patients recruited from 15 outpatient dialysis centers in North Carolina completed semistructured interviews on information provision and communication about the initiation of dialysis. These data were examined with content analysis. In addition, informed decision-making (IDM) scores were created by summing patient responses (yes/no) to 10 questions about the decision-making. Results The mean IDM score was 4.4 (of 10; SD = 2.0); 67% scored 5 or lower. Age at the time of decision-making (r = −0.27, P = 0.006), years of education (r = 0.24, P = 0.02) and presence of a warning about progressing to end-stage kidney disease (t = 2.9, P = 0.005) were significantly associated with IDM scores. Nearly 70% said that the risks and burdens of dialysis were not mentioned at all, and only one patient recalled that the doctor offered the option of not starting dialysis. While a majority (67%) said that they felt they had no choice about starting dialysis (because the alternative would be death) or about dialysis modality, only 21.2% said that they had felt rushed to make a decision. About one-third of the patients perceived that the decision to start dialysis and modality was already made by the doctor. Conclusions A majority of patients felt unprepared and ill-informed about the initiation of dialysis. Improving the extent of IDM about dialysis may optimize patient preparation prior to starting treatment and their perceptions about the decision-making process. PMID:23901048
The economic considerations of patients and caregivers in choice of dialysis modality
Howard, Kirsten; Tong, Allison; Palmer, Suetonia C.; Marshall, Mark R.; Morton, Rachael L.
2016-01-01
Abstract Introduction Broader adoption of home dialysis could lead to considerable cost savings for health services. Globally, however, uptake remains low. The aim of this study was to describe patient and caregiver perspectives of the economic considerations that influence dialysis modality choice, and elicit policy‐relevant recommendations. Methods Semistructured interviews with predialysis or dialysis patients and their caregivers, at three hospitals in New Zealand. Interview transcripts were analyzed thematically. Findings 43 patients and 9 caregivers (total n = 52) participated. The three themes related to economic considerations were: (i) productivity losses associated with changes in employment; (ii) the need for personal subsidization of home dialysis expenses; and (iii) the role of socio‐economic disadvantage as a barrier to home dialysis. Patients weighed the flexibility of home dialysis which allowed them to remain employed, against time required for training and out‐of‐pocket costs. Patients saw the lack of reimbursement of home dialysis costs as unjust and suggested that reimbursement would incentivize home dialysis uptake. Social disadvantage was a barrier to home dialysis as patients’ housing was often unsuitable; they could not afford the additional treatment costs. Home hemodialysis was considered to have the highest out‐of‐pocket costs and was sometimes avoided for this reason. Discussion Our data suggests that economic considerations underpin the choices patients make about dialysis treatments, however these are rarely reported. To promote home dialysis, strategies to improve employment retention and housing, and to minimize out‐of‐pocket costs, need to be addressed directly by healthcare providers and payers. PMID:27196634
Pishvar, Maya; Amirkhosravi, Mehrad; Altan, M Cengiz
2018-05-17
This work demonstrates a protocol to improve the quality of composite laminates fabricated by wet lay-up vacuum bag processes using the recently developed magnet assisted composite manufacturing (MACM) technique. In this technique, permanent magnets are utilized to apply a sufficiently high consolidation pressure during the curing stage. To enhance the intensity of the magnetic field, and thus, to increase the magnetic compaction pressure, the magnets are placed on a magnetic top plate. First, the entire procedure of preparing the composite lay-up on a magnetic bottom steel plate using the conventional wet lay-up vacuum bag process is described. Second, placement of a set of Neodymium-Iron-Boron permanent magnets, arranged in alternating polarity, on the vacuum bag is illustrated. Next, the experimental procedures to measure the magnetic compaction pressure and volume fractions of the composite constituents are presented. Finally, methods used to characterize microstructure and mechanical properties of composite laminates are discussed in detail. The results prove the effectiveness of the MACM method in improving the quality of wet lay-up vacuum bag laminates. This method does not require large capital investment for tooling or equipment and can also be used to consolidate geometrically complex composite parts by placing the magnets on a matching top mold positioned on the vacuum bag.
Daugirdas, John T; Levin, Nathan W; Kotanko, Peter; Depner, Thomas A; Kuhlmann, Martin K; Chertow, Glenn M; Rocco, Michael V
2008-01-01
A number of denominators for scaling the dose of dialysis have been proposed as alternatives to the urea distribution volume (V). These include resting energy expenditure (REE), mass of high metabolic rate organs (HMRO), visceral mass, and body surface area. Metabolic rate is an unlikely denominator as it varies enormously among humans with different levels of activity and correlates poorly with the glomerular filtration rate. Similarly, scaling based on HMRO may not be optimal, as many organs with high metabolic rates such as spleen, brain, and heart are unlikely to generate unusually large amounts of uremic toxins. Visceral mass, in particular the liver and gut, has potential merit as a denominator for scaling; liver size is related to protein intake and the liver, along with the gut, is known to be responsible for the generation of suspected uremic toxins. Surface area is time-honored as a scaling method for glomerular filtration rate and scales similarly to liver size. How currently recommended dialysis doses might be affected by these alternative rescaling methods was modeled by applying anthropometric equations to a large group of dialysis patients who participated in the HEMO study. The data suggested that rescaling to REE would not be much different from scaling to V. Scaling to HMRO mass would mandate substantially higher dialysis doses for smaller patients of either gender. Rescaling to liver mass would require substantially more dialysis for women compared with men at all levels of body size. Rescaling to body surface area would require more dialysis for smaller patients of either gender and also more dialysis for women of any size. Of these proposed alternative rescaling measures, body surface area may be the best, because it reflects gender-based scaling of liver size and thereby the rate of generation of uremic toxins.
Quality of life in patients on chronic dialysis in South Africa: a comparative mixed methods study.
Tannor, Elliot K; Archer, Elize; Kapembwa, Kenneth; van Schalkwyk, Susan C; Davids, M Razeen
2017-01-05
The increasing prevalence of treated end-stage renal disease and low transplant rates in Africa leads to longer durations on dialysis. Dialysis should not only be aimed at prolonging lives but also improve quality of life (QOL). Using mixed methods, we investigated the QOL of patients on chronic haemodialysis (HD) and peritoneal dialysis (PD). We conducted a cross-sectional study at Tygerberg Hospital in Cape Town, South Africa. All the PD patients were being treated with continuous ambulatory peritoneal dialysis. The KDQOL-SF 1.3 questionnaire was used for the quantitative phase of the study. Thereafter, focus-group interviews were conducted by an experienced facilitator in groups of HD and PD patients. Electronic recordings were transcribed verbatim and analysed manually to identify emerging themes. A total of 106 patients completed questionnaires and 36 of them participated in the focus group interviews. There was no difference between PD and HD patients in the overall KDQOL-SF scores. PD patients scored lower with regard to symptoms (P = 0.005), energy/fatigue (P = 0.025) and sleep (P = 0.023) but scored higher for work status (P = 0.005) and dialysis staff encouragement (P = 0.019) than those on HD. Symptoms and complications were verbalised more in the PD patients, with fear of peritonitis keeping some housebound. PD patients were more limited by their treatment modality which impacted on body image, sexual function and social interaction but there were less dietary and occupational limitations. Patients on each modality acknowledged the support received from family and dialysis staff but highlighted the lack of support from government. PD patients had little opportunity for interaction with one another and therefore enjoyed less support from fellow patients. PD patients experienced a heavier symptom burden and greater limitations related to their dialysis modality, especially with regards to social functioning. The mixed-methods approach helped to identify several issues affecting quality of life which are amenable to intervention.
Gorham, Gillian; Howard, Kirsten; Togni, Samantha; Lawton, Paul; Hughes, Jaquelyne; Majoni, Sandawana William; Brown, Sarah; Barnes, Sue; Cass, Alan
2017-05-03
Australia's Northern Territory (NT) has the country's highest incidence and prevalence of kidney disease. Indigenous people from remote areas suffer the heaviest disease burden. Concerns regarding cost and sustainability limit the provision of dialysis treatments in remote areas and most Indigenous people requiring dialysis relocate to urban areas. However, this dislocation of people from their family, community and support networks may prove more costly when the broader health, societal and economic consequences for the individual, family and whole of government are considered. The Dialysis Models of Care Study is a large cross organisation mixed methods study. It includes a retrospective (2000-2014) longitudinal data linkage study of two NT cohorts: Renal Cohort 1- comprising approximately 2000 adults who received dialysis and Renal Cohort 2- comprising approximately 400 children of those adults. Linkage of administrative data sets from the Australian and New Zealand Dialysis and Transplant Registry, NT Departments of Health, Housing and Education by a specialist third party (SA/NT Datalink) will enable extraction of activity, financial and outcome data. Interviews with patients, clinicians and service providers, using a snowball technique, will canvass relevant issues and assist in determining the full costs and impacts of the five most used dialysis Models of Care. The study uses a mixed methods approach to investigate the quantitative and qualitative dimensions of the full costs and outcomes associated with the choice of particular dialysis models of care for any given patient. The study includes a large data linkage component that for the first time links health, housing and education data to fully analyse and evaluate the impact on patients, their families and the broader community, resulting from the relocation of people for treatment. The study will generate a large amount of activity, financial and qualitative data that will investigate health costs less directly related to dialysis treatment, costs to government such as housing and/or education and the health, social and economic outcomes experienced by patients. This approach fills an evidence gap critical to health service planners.
Salo, Hanna; Berisha, Anna-Kaisa; Mäkinen, Joni
2016-03-01
This is the first study seasonally applying Sphagnum papillosum moss bags and vertical snow samples for monitoring atmospheric pollution. Moss bags, exposed in January, were collected together with snow samples by early March 2012 near the Harjavalta Industrial Park in southwest Finland. Magnetic, chemical, scanning electron microscopy-energy dispersive X-ray spectroscopy (SEM-EDX), K-means clustering, and Tomlinson pollution load index (PLI) data showed parallel spatial trends of pollution dispersal for both materials. Results strengthen previous findings that concentrate and slag handling activities were important (dust) emission sources while the impact from Cu-Ni smelter's pipe remained secondary at closer distances. Statistically significant correlations existed between the variables of snow and moss bags. As a summary, both methods work well for sampling and are efficient pollutant accumulators. Moss bags can be used also in winter conditions and they provide more homogeneous and better controlled sampling method than snow samples. Copyright © 2015. Published by Elsevier B.V.
Reviewing and comparing self-concept in patients undergoing hemodialysis and peritoneal dialysis
Shahgholian, Nahid; Tajdari, Setareh; Nasiri, Mahmoud
2012-01-01
Background: Chronic renal disease is a health problem in today’s world. In the end-stages of renal disease patients depend upon alternative therapies including dialysis for their survival. However, dialysis causes several stressors on physical, mental and social performance of patients. The present study aimed to review and compare the self-concept in patients undergoing hemodialysis and peritoneal dialysis. Materials and Methods: This was a case-control study including two groups of patients, undergoing hemodialysis and peritoneal dialysis, who referred to Al-Zahra and Ali Asghar Hospitals, which are affiliated to Isfahan University of Medical Sciences. These groups were compared to the control group. Data were collected through completing the form of demographic characteristics and a questionnaire, written by the researcher, pertaining to the self-concept which was collected by the samples. The data were analyzed by the Software SPSS version 18. Findings: ANOVA (analysis of variance) showed that statistically there was a significant difference between mean score of self-concept in the three physical (body-image), psychological, and social self aspects in the two groups of hemodialysis and peritoneal dialysis with the control group; however, Duncan’s post-hoc analysis showed no significant difference between mean score of self-concept in the three mentioned aspects in the two groups of hemodialysis and peritoneal dialysis. Furthermore, ANOVA (analysis of variance) showed that there was no significant difference between mean score of the spiritual aspect of the self-concept in the two groups of hemodialysis and peritoneal dialysis with the control group. Duncan’s post-hoc analysis also showed no significant difference in this aspect between the two groups of hemodialysis and peritoneal dialysis. Conclusions: Patients undergoing dialysis have many psychological disorders and the type of dialysis is not of much importance in this regard; therefore, adequate education and information for clients in order to use appropriate methods of adaptation as well as appropriate social relationship, continuing social support and developing health policies seem necessary in order to prevent mental disorders and providing required services and supports for patients. PMID:23833607
The interview with a patient on dialysis: feeling, emotions and fears.
Brunori, Francesco; Dozio, Beatrice; Colzani, Sara; Pozzi, Marco; Pisano, Lucia; Galassi, Andrea; Santorelli, Gennaro; Auricchio, Sara; Busnelli, Luisa; Di Carlo, Angela; Viganò, Monica; Calabrese, Valentina; Mariani, Laura; Mossa, Monica; Longoni, Stefania; Scanziani, Renzo
2016-01-01
This study has been performed in the Nephrology and Dialysis Unit, in Desio Hospital, Italy. The aim of this study is to evaluate, starting from research questions, which information is given to patient in the pre-dialysis colloquia for his/her chosen dialysis methods. Moreover, the study evaluated feelings, emotions and fears since the announcement of the necessity of dialysis treatment. The objective of the study was reached through the interview with patients on dialysis. The fact-finding survey was based on the tools of social research, as the semi-structured interview. Instead of using the questionnaire, even though it make it easier to collect larger set of data, the Authors decided to interview patients in person, since the interview allows direct patient contact and to build a relationship of trust with the interviewer, in order to allow patient explain better his/her feeling.
Harrison, Jesse P; Boardman, Carl; O'Callaghan, Kenneth; Delort, Anne-Marie; Song, Jim
2018-05-01
Plastic litter is encountered in aquatic ecosystems across the globe, including polar environments and the deep sea. To mitigate the adverse societal and ecological impacts of this waste, there has been debate on whether 'biodegradable' materials should be granted exemptions from plastic bag bans and levies. However, great care must be exercised when attempting to define this term, due to the broad and complex range of physical and chemical conditions encountered within natural ecosystems. Here, we review existing international industry standards and regional test methods for evaluating the biodegradability of plastics within aquatic environments (wastewater, unmanaged freshwater and marine habitats). We argue that current standards and test methods are insufficient in their ability to realistically predict the biodegradability of carrier bags in these environments, due to several shortcomings in experimental procedures and a paucity of information in the scientific literature. Moreover, existing biodegradability standards and test methods for aquatic environments do not involve toxicity testing or account for the potentially adverse ecological impacts of carrier bags, plastic additives, polymer degradation products or small (microscopic) plastic particles that can arise via fragmentation. Successfully addressing these knowledge gaps is a key requirement for developing new biodegradability standard(s) for lightweight carrier bags.
Leaf litter bags as an index to populations of northern two-lined salamanders (Eurycea bislineata)
Chalmers, R.J.; Droege, S.
2002-01-01
Concern about recent amphibian declines has led to research on amphibian populations, but few statistically tested, standardized methods of counting amphibians exist. We tested whether counts of northern two-lined salamander larvae (Eurycea bislineata) sheltered in leaf litter bags--a relatively new, easily replicable survey technique--had a linear correlation to total number of larvae. Using experimental enclosures placed in streams, we compared number of salamanders found in artificial habitat (leaf litter bags) with total number of salamanders in each enclosure. Low numbers of the animals were found in leaf litter bags, and the relative amount of variation in the index (number of animals in leaf litter bags compared to total number of animals in stream enclosures) was high. The index of salamanders in leaf litter bags was not significantly related to total number of salamanders in enclosures for two-thirds of the replicates or with pooled replicates (P= 0.066). Consequently, we cannot recommend using leaf litter bags to index populations of northern two-lined salamanders.
Stańczyk, Małgorzata; Miklaszewska, Monika; Zachwieja, Katarzyna; Wierciński, Ryszard; Stankiewicz, Roman; Firszt-Adamczyk, Agnieszka; Zachwieja, Jacek; Borzęcka, Hanna; Zagożdżon, Ilona; Ziółkowska, Helena; Leszczyńska, Beata; Medyńska, Anna; Adamczyk, Piotr; Szczepańska, Maria; Tkaczyk, Marcin
2016-03-01
Despite vast availability of modern methods of treatment of chronic kidney disease and its complications, the short stature still is a major point of concern in adolescents with chronic kidney disease. The aim of the study was to assess changes in growth and nutritional status of Polish children on renal replacement therapy in the decade, 2004-2013. The study was designed as a cross-sectional analysis of anthropometric values and selected indices of growth status amongst children receiving dialysis in Poland between the years 2004 and 2013. Data were acquired during two different multicentre studies on hypertension in dialyzed children in Poland. Basic anthropometric parameters (body weight, body height/length, body mass index - BMI), dialysis adequacy and duration of RRT were assessed. The study showed that anthropometric parameters of children undergoing renal replacement therapy had not significantly changed in the last 10 years of observation. Children on RRT were still of short stature despite availability of modern methods of hormonal therapy and nutrition. Median of height z-score was -2.10 in 2004 and -2.19 in 2013. Expected clinical improvement in these measures was not proven. The cause of chronic kidney disease, method of dialysis, time on dialysis or dialysis adequacy did not influence the anthropometric parameters significantly in dialyzed children in Poland. Copyright © 2015 Medical University of Bialystok. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
Wilmink, Teun; Powers, Sarah; Hollingworth, Lee; Stevenson, Tamasin
2018-05-01
To study the effect of cannulation time on arteriovenous fistula (AVF) survival. Methods. Analysis of two prospective databases of access operations and dialysis sessions from 12 January 2002 through 4 January 2015 with follow-up until 4 January 2016. First cannulation time (FCT), defined from operation to first cannulation, was categorized as <2 weeks, 2-4 weeks, 4-8 weeks, 8-16 weeks and ≥16 weeks. Early cannulation was defined as FCT within 4 weeks. AVF survival was defined as the date until the AVF was abandoned. Maximum machine blood flow rate (BFR) for the first 29 dialysis sessions on AVF was analysed. Altogether, 1167 AVF with functional dialysis use were analysed: 667 (57%) radial cephalic AVF, 383 (33%) brachiocephalic AVF and 117 (10%) brachiobasilic AVF. The 631 (54%) AVF created in on-dialysis patients were analysed separately from 536 (46%) AVF created in pre-dialysis patients. AVF survival was similar between cannulation categories for both pre-dialysis patients (P = 0.19) and on-dialysis patients (P = 0.83). Early cannulation was associated with similar AVF survival in both pre-dialysis patients (P = 0.82) and on-dialysis patients (P = 0.17). Six consecutive successful cannulations from the start were associated with improved AVF survival (P = 0.0002). A below-median BFR at the start of dialysis was associated with better AVF survival (P < 0.0001). A below-median increase in BFR in the first 2 months was associated with worse AVF survival (P = 0.007). The type of AVF, diabetes, pre-dialysis state at operation and six successful cannulations from the start were independent predictors for AVF survival. FCT is not associated with AVF survival. Failures to achieve six successful cannulations from the start of dialysis and higher machine BFR in the first week of dialysis are associated with decreased AVF survival.
Development of Spray on Bag for manufacturing of large composites parts: Diffusivity analysis
NASA Astrophysics Data System (ADS)
Dempah, Maxime Joseph
Bagging materials are utilized in many composites manufacturing processes. The selection is mainly driven by cost, temperature requirements, chemical compatibility and tear properties of the bag. The air barrier properties of the bag are assumed to be adequate or in many cases are not considered at all. However, the gas barrier property of a bag is the most critical parameter, as it can negatively affect the quality of the final laminate. The barrier property is a function of the bag material, uniformity, thickness and temperature. Improved barrier properties are needed for large parts, high pressure consolidated components and structures where air stays entrapped on the part surface. The air resistance property of the film is defined as permeability and is investigated in this thesis. A model was developed to evaluate the gas transport through the film and an experimental cell was implemented to characterize various commercial films. Understanding and characterizing the transport phenomena through the film allows optimization of the bagging material for various manufacturing processes. Spray-on-Bag is a scalable alternative bagging method compared to standard films. The approach allows in-situ fabrication of the bag on large and complex geometry structures where optimization of the bag properties can be varied on a local level. An experimental setup was developed and implemented using a six axis robot and an automated spraying system. Experiments were performed on a flat surface and specimens were characterized and compared to conventional films. Air barrier properties were within range of standard film approaches showing the potential to fabricate net shape bagging structures in an automated process.
An overview of regular dialysis treatment in Japan (as of 31 December 2012).
Nakai, Shigeru; Hanafusa, Norio; Masakane, Ikuto; Taniguchi, Masatomo; Hamano, Takayuki; Shoji, Tetsuo; Hasegawa, Takeshi; Itami, Noritomo; Yamagata, Kunihiro; Shinoda, Toshio; Kazama, Junichiro James; Watanabe, Yuzo; Shigematsu, Takashi; Marubayashi, Seiji; Morita, Osamu; Wada, Atsushi; Hashimoto, Seiji; Suzuki, Kazuyuki; Nakamoto, Hidetomo; Kimata, Naoki; Wakai, Kenji; Fujii, Naohiko; Ogata, Satoshi; Tsuchida, Kenji; Nishi, Hiroshi; Iseki, Kunitoshi; Tsubakihara, Yoshiharu
2014-12-01
A nationwide statistical survey of 4279 dialysis facilities was conducted at the end of 2012, among which 4238 responded (99.0%). The number of new dialysis patients was 38055 in 2012. Since 2008, the number of new dialysis patients has remained almost the same without any marked increase or decrease. The number of dialysis patients who died in 2012 was 30710; a slight decrease from 2011 (30743). The dialysis patient population has been growing every year in Japan; it was 310007 at the end of 2012, which exceeded 310000 for the first time. The number of dialysis patients per million at the end of 2012 was 2431.2. The crude death rate of dialysis patients in 2012 was 10.0%, a slight decrease from that in 2011 (10.2%). The mean age of new dialysis patients was 68.5 years and the mean age of the entire dialysis patient population was 66.9 years. The most common primary cause of renal failure among new dialysis patients was diabetic nephropathy (44.2%). The actual number of new dialysis patients with diabetic nephropathy has been approximately 16000 for the last few years. Diabetic nephropathy was also the most common primary disease among the entire dialysis patient population (37.1%), followed by chronic glomerulonephritis (33.6%). The percentage of dialysis patients with diabetic nephropathy has been continuously increasing, whereas not only the percentage but also the actual number of dialysis patients with chronic glomerulonephritis has decreased. The number of patients who underwent hemodiafiltration (HDF) at the end of 2012 was 21725, a marked increase from that in 2011 (14115). In particular, the number of patients who underwent on-line HDF increased threefold from 4890 in 2011 to 14069 in 2012. From the results of the facility survey, the number of patients who underwent peritoneal dialysis (PD) was 9514 and that of patients who did not undergo PD despite having a PD catheter in the abdominal cavity was 347. From the results of the patient survey, among the PD patients, 1932 also underwent another dialysis method using extracorporeal circulation, such as hemodialysis (HD) and HDF. The number of patients who underwent HD at home in 2012 was 393, a marked increase from that in 2011 (327). © 2014 Japanese Society for Dialysis Therapy. Reproduced with permission.
Comparison of Hospitalization Rates among For-Profit and Nonprofit Dialysis Facilities
Johansen, Kirsten L.; Romano, Patrick S.; Chertow, Glenn M.; Mu, Yi; Ishida, Julie H.; Grimes, Barbara; Kaysen, George A.; Nguyen, Danh V.
2014-01-01
Summary Background and objectives The vast majority of US dialysis facilities are for-profit and profit status has been associated with processes of care and outcomes in patients on dialysis. This study examined whether dialysis facility profit status was associated with the rate of hospitalization in patients starting dialysis. Design, setting, participants, & methods This was a retrospective cohort study of Medicare beneficiaries starting dialysis between 2005 and 2008 using data from the US Renal Data System. All-cause hospitalization was examined and compared between for-profit and nonprofit dialysis facilities through 2009 using Poisson regression. Companion analyses of cause-specific hospitalization that are likely to be influenced by dialysis facility practices including hospitalizations for heart failure and volume overload, access complications, or hyperkalemia were conducted. Results The cohort included 150,642 patients. Of these, 12,985 (9%) were receiving care in nonprofit dialysis facilities. In adjusted models, patients receiving hemodialysis in for-profit facilities had a 15% (95% confidence interval [95% CI], 13% to 18%) higher relative rate of hospitalization compared with those in nonprofit facilities. Among patients receiving peritoneal dialysis, the rate of hospitalization in for-profit versus nonprofit facilities was not significantly different (relative rate, 1.07; 95% CI, 0.97 to 1.17). Patients on hemodialysis receiving care in for-profit dialysis facilities had a 37% (95% CI, 31% to 44%) higher rate of hospitalization for heart failure or volume overload and a 15% (95% CI, 11% to 20%) higher rate of hospitalization for vascular access complications. Conclusions Hospitalization rates were significantly higher for patients receiving hemodialysis in for-profit compared with nonprofit dialysis facilities. PMID:24370770
Secular trends in acute dialysis after elective major surgery — 1995 to 2009
Siddiqui, Nausheen F.; Coca, Steven G.; Devereaux, Philip J.; Jain, Arsh K.; Li, Lihua; Luo, Jin; Parikh, Chirag R.; Paterson, Michael; Philbrook, Heather Thiessen; Wald, Ron; Walsh, Michael; Whitlock, Richard; Garg, Amit X.
2012-01-01
Background: Acute kidney injury is a serious complication of elective major surgery. Acute dialysis is used to support life in the most severe cases. We examined whether rates and outcomes of acute dialysis after elective major surgery have changed over time. Methods: We used data from Ontario’s universal health care databases to study all consecutive patients who had elective major surgery at 118 hospitals between 1995 and 2009. Our primary outcomes were acute dialysis within 14 days of surgery, death within 90 days of surgery and chronic dialysis for patients who did not recover kidney function. Results: A total of 552 672 patients underwent elective major surgery during the study period, 2231 of whom received acute dialysis. The incidence of acute dialysis increased steadily from 0.2% in 1995 (95% confidence interval [CI] 0.15–0.2) to 0.6% in 2009 (95% CI 0.6–0.7). This increase was primarily in cardiac and vascular surgeries. Among patients who received acute dialysis, 937 died within 90 days of surgery (42.0%, 95% CI 40.0–44.1), with no change in 90-day survival over time. Among the 1294 patients who received acute dialysis and survived beyond 90 days, 352 required chronic dialysis (27.2%, 95% CI 24.8–29.7), with no change over time. Interpretation: The use of acute dialysis after cardiac and vascular surgery has increased substantially since 1995. Studies focusing on interventions to better prevent and treat perioperative acute kidney injury are needed. PMID:22733671
Bolasco, Piergiorgio; Contu, Antonio; Meloni, Patrizia; Vacca, Dorio; Galfrè, Andrea
2012-08-01
The present report attempts to illustrate the positive impact on the microbiological quality of dialysis patients over a 15-year period through the progressive implementation of state-of-the-art technological strategies and the optimization of microbiological surveillance procedures in five dialysis units in Sardinia. Following on better microbiological, quality controls of dialysis water and improvement of procedures and equipment, a drastic improvement of microbiological water quality was observed in a total of 945 samples. The main aim was to introduce the use of microbiological culture methods as recommended by the most important guidelines. The microbiological results obtained have led to a progressive refining of controls and introduction of new materials and equipment, including two-stage osmosis and piping distribution rings featuring a greater capacity to prevent biofilm adhesion. The actions undertaken have resulted in unexpected quality improvements. Dialysis water should be viewed by the nephrologist as a medicinal product exerting a demonstrable positive impact on microinflammation in dialysis patients. A synergic effort between nephrologists and microbiologists undoubtedly constitutes the most effective means of preventing dialysis infections.
Improved BC method of Compomat G4 for expression of BCs twice from whole blood in top and top bags.
Deng, Xiao-Yan; Wu, Xiao-Man; Zhao, Yang; Luo, Hong; Jia, Hong-Yun; Wang, Zhong-Ying; He, Bo; Wang, Chuan-Xi
2011-05-01
The aim of this paper was to evaluate an improved buffy coat (BC) method of Compomat G4 for automated expression of BCs twice from whole blood (WB) in top and top (T&T) bags. WB was separated using hard spin centrifugation (2,988g, 10 min) into layers of blood components by specific gravity, and different components were subsequently expressed into satellite bags in the T&T system using the manual BC method, the conventional BC method of G4, and our improved BC method of G4. In the improved BC method, an accessorial device we have named a 'gravity press' was designed and installed on the top flat of G4 to produce gravitational pressure on the plasma bag so as to exclude air and some of plasma to the upper compartment of the slide after BCs were expressed for the first time. The residual BCs in the upper compartment were expressed a second time by extending the upper press once more. All of the pooled BCs were centrifuged by soft spin (402g, 10 min) and upper platelet-rich supernatant was manually expressed into a platelet container by the plasma extractor. In vitro studies of blood components and pooled platelet concentrates (PCs) revealed no significant differences in BC blood components and platelet recovery of pooled platelets (61 ± 9 vs. 60 ± 7%, n = 12, p > 0.05) between the improved BC method and the conventional BC method; all components met our specifications for blood products. We suggest that the new BC method for use of T&T bags may improve the collection of BCs.
Asphyxial suicide by inhalation of chloroform inside a plastic bag.
Zorro, Andres Rodriguez
2014-01-01
Asphyxia suicide by placing a plastic bag over the head in addition with inhalation of gases or use of sedative substances is an unusual method of committing suicide, but frequently referenced by right to die groups in the Internet. This article reports 2 suicides in which chloroform was used to induce unconsciousness and subsequent asphyxia by placing the head in a plastic bag. Case histories of 2 males, ages 23 and 28, are described with special emphasis on characteristics death related to suffocation using plastic bags and chloroform. The final remarkable point in both cases is that the victims previously searched the WEB for instructions of suicide methods. The importance of the phenomenon of misuse of Internet by young people who commit suicide is stressed. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
The modification of renal transplantation with the usage of own polyethylene receptacle.
Pupka, Artur; Chudoba, Paweł; Patrzałek, Dariusz; Janczak, Dariusz; Szyber, Piotr
2003-01-01
In this study a method of elimination of the second warm ischemia is shown. The method is based on the application of a specially constructed polyethylene bag, in which the transplanted kidney is placed in the time course from a removal from ice to the reconstruction of vessel flow. The bag is built of polyethylene foil HDPE of low density produced under high pressure. Own construction of the bag (three spaces and polyethylene) enables the storage of a transplanted organ at the stable temperature +4 Celsius degrees. Thanks to the separation of containers for melting ice and for the kidney, possible becomes unrestrained performance of both venous and arterial anastomosis independently of existing operative conditions. Due to the applied method of the elimination of the second warm ischemia with the usage of own construction of polyethylene bag HDPE, one can expect better early renal function after transplantation--decrease in the number of cases and shortening of the time of acute tubular necrosis (ATN--Acute Tubular Necrosis).
Automobile driver fatalities in frontal impacts: air bags compared with manual belts.
Zador, P L; Ciccone, M A
1993-01-01
OBJECTIVES. The effectiveness of air bags was estimated in this study by comparing driver fatalities in frontal crashes with driver fatalities in nonfrontal crashes, for cars with air bags and manual belts and cars with manual belts only. METHODS. Fatal Accident Reporting System data for drivers fatally injured during 1985 to 1991 in 1985 to 1991 model year cars that were equipped with air bags in or before model year 1991 were analyzed. RESULTS. Driver fatalities in frontal crashes in air bag cars were 28% lower than those in comparable cars with manual belts only. This percentage was used for estimating the overall fatality reduction in air bag cars. The reduction was greater in large cars (50%) than in midsize cars (19%) or in small cars (14%). Air bags reduced driver fatalities in frontal crashes involving ejection by about 9%. Fatalities in frontal crashes among drivers who were reportedly using manual belts at the time of the crash were reduced by about 15%. The comparable reduction among drivers who were reportedly not using manual belts was 31%. CONCLUSION. It was estimated that air bags reduced the total number of all driver fatalities by about 19%. PMID:8484445
Santos-Folgar, Myriam; Otero-Agra, Martín; Fernández-Méndez, Felipe; Hermo-Gonzalo, María Teresa; Barcala-Furelos, Roberto; Rodríguez-Núñez, Antonio
2018-02-08
It has been observed that health professionals have difficulty performing quality cardiopulmonary resuscitation (CPR). The aim of this study was to compare the quality of ventilations performed by Nursing students on an infant model using different methods (mouth-to-mouth-and-nose or bag-valve-mask). A quasi-experimental cross-sectional study was performed that included 46 second-year Nursing students. Two quantitative 4-minute tests of paediatric CPR were performed: a) mouth-to-mouth-and-nose ventilations, and b) ventilations with bag-valve-mask. A Resusci Baby QCPR Wireless SkillReporter® mannequin from Laerdal was used. The proportion of ventilations with adequate, excessive, and insufficient volume was recorded and analysed, as well as the overall quality of the CPR (ventilations and chest compressions). The students were able to give a higher number of ventilations with adequate volume using the mouth-to-mouth-and-nose method (55±22%) than with the bag-valve-mask (28±16%, P<.001). The overall quality of the CPR was also significantly higher when using the mouth-to-mouth-and-nose method (60±19 vs. 48±16%, P<.001). Mouth-to-mouth-and-nose ventilation method is more efficient than bag-valve-mask ventilations in CPR performed by nursing students with a simulated infant model. Copyright © 2018. Publicado por Elsevier España, S.L.U.
Khangura, Jaspreet; Culleton, Bruce F; Manns, Braden J; Zhang, Jianguo; Barnieh, Lianne; Walsh, Michael; Klarenbach, Scott W; Tonelli, Marcello; Sarna, Magdalena; Hemmelgarn, Brenda R
2010-06-24
Left ventricular (LV) hypertrophy is common among patients on hemodialysis. While a relationship between blood pressure (BP) and LV hypertrophy has been established, it is unclear which BP measurement method is the strongest correlate of LV hypertrophy. We sought to determine agreement between various blood pressure measurement methods, as well as identify which method was the strongest correlate of LV hypertrophy among patients on hemodialysis. This was a post-hoc analysis of data from a randomized controlled trial. We evaluated the agreement between seven BP measurement methods: standardized measurement at baseline; single pre- and post-dialysis, as well as mean intra-dialytic measurement at baseline; and cumulative pre-, intra- and post-dialysis readings (an average of 12 monthly readings based on a single day per month). Agreement was assessed using Lin's concordance correlation coefficient (CCC) and the Bland Altman method. Association between BP measurement method and LV hypertrophy on baseline cardiac MRI was determined using receiver operating characteristic curves and area under the curve (AUC). Agreement between BP measurement methods in the 39 patients on hemodialysis varied considerably, from a CCC of 0.35 to 0.94, with overlapping 95% confidence intervals. Pre-dialysis measurements were the weakest predictors of LV hypertrophy while standardized, post- and inter-dialytic measurements had similar and strong (AUC 0.79 to 0.80) predictive power for LV hypertrophy. A single standardized BP has strong predictive power for LV hypertrophy and performs just as well as more resource intensive cumulative measurements, whereas pre-dialysis blood pressure measurements have the weakest predictive power for LV hypertrophy. Current guidelines, which recommend using pre-dialysis measurements, should be revisited to confirm these results.
Zhang, Haisheng; Xue, Jing; Zhao, Huanxia; Zhao, Xinshuai; Xue, Huanhuan; Sun, Yuhan; Xue, Wanrui
2018-05-03
Background : The composition and sequence of amino acids have a prominent influence on theantioxidant activities of peptides. Objective : A series of isolation and purification experiments was conducted to explore the amino acid sequence of antioxidant peptides, which led to its antioxidation causes. Methods : The degreased apricot seed kernels were hydrolyzed by compound proteases of alkaline protease and flavor protease (3:2, u/u) to prepare apricot seed kernel hydrolysates (ASKH). ASKH were separated into ASKH-A and ASKH-B by dialysis bag. ASKH-B (MW < 3.5 kDa) was further separated into fractions by Sephadex G-25 and G-15 gel-filtration chromatography. Reversed-phase HPLC (RP-HPLC) was performed to separate fraction B4b into two antioxidant peptides (peptide B4b-4 and B4b-6). Results : The amino acid sequences were Val-Leu-Tyr-Ile-Trp and Ser-Val-Pro-Tyr-Glu, respectively. Conclusions : The results suggested that ASKH antioxidant peptides may have potential utility as healthy ingredients and as food preservatives due to their antioxidant activity. Highlights : Materials with regional characteristics were selected to explore, and hydrolysates were identified by RP-HPLC and matrix-assisted laser desorption ionization-time-of-flight-MS to obtain amino acid sequences.
Wood, Joseph; Mahajan, Ekta; Shiratori, Masaru
2013-01-01
The use of disposable bags for cell culture media storage has grown significantly in the past decade. Some of the key advantages of using disposable bags relative to non-disposable containers include increased product throughput, decreased cleaning validation costs, reduced risk of cross contamination and lower facility costs. As the scope of use of disposable bags for cell culture applications increases, problematic bags and scenarios should be identified and addressed to continue improving disposables technologies and meet the biotech industry's needs. In this article, we examine a cell culture application wherein media stored in disposable bags is warmed at 37°C before use for cell culture operations. A problematic bag film was identified through a prospective and retrospective cell culture investigation. The investigation provided information on the scope and variation of the issue with respect to different Chinese hamster ovary (CHO) cell lines, cell culture media, and application-specific parameters. It also led to the development of application-specific test methods and enabled a strategy for disposable bag film testing. The strategy was implemented for qualifying an alternative bag film for use in our processes. In this test strategy, multiple lots of 13 bag film types, encompassing eight vendors were evaluated using a three round, cell culture-based test strategy. The test strategy resulted in the determination of four viable bag film options based on the technical data. The results of this evaluation were used to conclude that a volatile or air-quenched compound, likely generated by gamma irradiation of the problematic bag film, negatively impacted cell culture performance. © 2013 American Institute of Chemical Engineers.
Peritoneal dialysis solutions--at a crossroad.
Diaz-Buxo, J A; Gotloib, L
2006-06-01
After many decades of evolution and with many choices available for the formulation of peritoneal dialysis fluids (PDF), we find ourselves at a crossroads. A review of related developments, laboratory trials and clinical evaluations is offered to stimulate future research in this area. The information presented here raises more questions than it provides answers, but opens the door to innumerable possibilities for improvement. The search for a biocompatible osmotic agent designed to replace those currently used has been frustrating and is far from being considered a success. Research on cytokines and other mediators of inflammation produced a huge amount of interesting scientific knowledge that may help our understanding. However, it is unlikely that it will identify a specifically targeted anticytokine, or combination of them, designed to neutralize and/or reverse inflammatory changes resulting from the use of poorly biocompatible PDF. The development of low glucose degradation product (GDP) solutions by means of multi-chambered bags appear to be a step in the right direction and perhaps is the most significant improvement in this field in many decades. GDPs are important, but not the only offenders or the exclusive source of oxidative stress. Thus, the addition of antioxidants to PDF formulations, in our opinion, deserves further consideration. Additionally, repopulation of the mesothelial monolayer by means of periodic autotransplantation of mesothelial cells may well become a useful tool to prevent and/or correct membrane failure. We are fortunate to have choices at this crossroad, which we must evaluate rigorously.
ERIC Educational Resources Information Center
Lustick, David
1997-01-01
Describes a simple activity that explores and reveals the principles of significant figures and scientific notation using a 500 gram bag of unpopped popcorn. Students must devise a method for determining the number of kernels in the bag. (DDR)
Shreay, Sanatan; Ma, Martin; McCluskey, Jill; Mittelhammer, Ron C; Gitlin, Matthew; Stephens, J Mark
2014-01-01
Objective To explore the relative efficiency of dialysis facilities in the United States and identify factors that are associated with efficiency in the production of dialysis treatments. Data Sources/Study Setting Medicare cost report data from 4,343 free-standing dialysis facilities in the United States that offered in-center hemodialysis in 2010. Study Design A cross-sectional, facility-level retrospective database analysis, utilizing data envelopment analysis (DEA) to estimate facility efficiency. Data Collection/Extraction Methods Treatment data and cost and labor inputs of dialysis treatments were obtained from 2010 Medicare Renal Cost Reports. Demographic data were obtained from the 2010 U.S. Census. Principal Findings Only 26.6 percent of facilities were technically efficient. Neither the intensity of market competition nor the profit status of the facility had a significant effect on efficiency. Facilities that were members of large chains were less likely to be efficient. Cost and labor savings due to changes in drug protocols had little effect on overall dialysis center efficiency. Conclusions The majority of free-standing dialysis facilities in the United States were functioning in a technically inefficient manner. As payment systems increasingly employ capitation and bundling provisions, these institutions will need to evaluate their efficiency to remain competitive. PMID:24237043
Noe, Gregory B.
2011-01-01
A modification of the resin-core method was developed and tested for measuring in situ soil N and P net mineralization rates in wetland soils where temporal variation in bidirectional vertical water movement and saturation can complicate measurement. The modified design includes three mixed-bed ion-exchange resin bags located above and three resin bags located below soil incubating inside a core tube. The two inner resin bags adjacent to the soil capture NH4+, NO3-, and soluble reactive phosphorus (SRP) transported out of the soil during incubation; the two outer resin bags remove inorganic nutrients transported into the modified resin core; and the two middle resin bags serve as quality-control checks on the function of the inner and outer resin bags. Modified resin cores were incubated monthly for a year along the hydrogeomorphic gradient through a floodplain wetland. Only small amounts of NH4+, NO3-, and SRP were found in the two middle resin bags, indicating that the modified resin-core design was effective. Soil moisture and pH inside the modified resin cores typically tracked changes in the surrounding soil abiotic environment. In contrast, use of the closed polyethylene bag method provided substantially different net P and N mineralization rates than modified resin cores and did not track changes in soil moisture or pH. Net ammonification, nitrifi cation, N mineralization, and P mineralization rates measured using modified resin cores varied through space and time associated with hydrologic, geomorphic, and climatic gradients in the floodplain wetland. The modified resin-core technique successfully characterized spatiotemporal variation of net mineralization fluxes in situ and is a viable technique for assessing soil nutrient availability and developing ecosystem budgets.
Effects of Physician Payment Reform on Provision of Home Dialysis
Erickson, Kevin F.; Winkelmayer, Wolfgang C.; Chertow, Glenn M.; Bhattacharya, Jay
2016-01-01
Objectives Patients with end-stage renal disease can receive dialysis at home or in-center. In 2004 the Centers for Medicare and Medicaid Services reformed physician payment for in-center hemodialysis care from a capitated to a tiered fee-for-service model, augmenting physician payment for frequent in-center visits. We evaluated whether payment reform influenced dialysis modality assignment. Study Design Cohort study of patients starting dialysis in the US in the three years before and after payment reform. Methods We conducted difference-in-difference analyses comparing patients with Traditional Medicare coverage (who were affected by the policy) to others with Medicare Advantage (who were unaffected by the policy). We also examined whether the policy had a more pronounced influence on dialysis modality assignment in areas with lower costs of traveling to dialysis facilities. Results Patients with Traditional Medicare coverage experienced a 0.7% (95% CI 0.2%–1.1%; p=0.003) reduction in the absolute probability of home dialysis use following payment reform compared to patients with Medicare Advantage. Patients living in areas with larger dialysis facilities (where payment reform made in-center hemodialysis comparatively more lucrative for physicians) experienced a 0.9% (95% CI 0.5%–1.4%; p<0.001) reduction in home dialysis use following payment reform compared to patients living in areas with smaller facilities (where payment reform made in-center hemodialysis comparatively less lucrative for physicians). Conclusions Transition from a capitated to tiered fee-for-service payment model for dialysis care resulted in fewer patients receiving home dialysis. This area of policy failure highlights the importance of considering unintended consequences of future physician payment reform efforts. PMID:27355909
Patient and family perspectives on peritoneal dialysis at home: findings from an ethnographic study.
Baillie, Jessica; Lankshear, Annette
2015-01-01
To discuss findings from an ethnographic study, considering the experiences of patients and families, using peritoneal dialysis at home in the United Kingdom. Peritoneal dialysis is a daily, life-preserving treatment for end-stage renal disease, undertaken in the patient's home. With ever-growing numbers of patients requiring treatment for this condition, the increased use of peritoneal dialysis is being promoted. While it is known that quality of life is reduced when using dialysis, few studies have sought to explore experiences of peritoneal dialysis specifically. No previous studies were identified that adopted an ethnographic approach. A qualitative design was employed, utilising ethnographic methodology. Ethical and governance approvals were gained in November 2010 and data were generated in 2011. Patients (n = 16) and their relatives (n = 9) were interviewed and observed using peritoneal dialysis in their homes. Thematic analysis was undertaken using Wolcott's (1994) three stage process: Description, Analysis and Interpretation. This article describes four themes: initiating peritoneal dialysis; the constraints of peritoneal dialysis due to medicalisation of the home environment and the imposition of rigid timetables; the uncertainty of managing crises and inevitable deterioration; and seeking freedom through creativity and hope of a kidney transplant. This study highlights the culture of patients and their families living with peritoneal dialysis. Despite the challenges posed by the treatment, participants were grateful they were able to self-manage at home. Furthermore, ethnographic methods offer an appropriate and meaningful way of considering how patients live with home technologies. Participants reported confusion about kidney transplantation and also how to identify peritonitis, and ongoing education from nurses and other healthcare professionals is thus vital. Opportunities for sharing experiences of peritoneal dialysis were valued by participants and further peer-support services should thus be considered. © 2014 John Wiley & Sons Ltd.
Flow visualization around an apple with and without bagging
NASA Astrophysics Data System (ADS)
Matsumoto, H.; Kubota, Y.; Ohishi, M.; Mochizuki, O.
2017-04-01
The typhoon often causes the vast damage to drop the apple before harvest. Many apples fall from trees by the strong wind. These apples are usually bagged to protect them from insects and control sun light for the apples colouring while they are ripening on the tree. We directly measured the drag force acting on an apple with and without bagging experimentally to bare the influence of the bagging on the dropping mechanism. There are two interesting results through the experiment: the drag coefficient of a naked apple is smaller than a sphere, and the bagging is a cause of increasing drag coefficient. To know the reason of these results, we visualized flow around the apple with and without bagging by using the hydrogen bubbles method in an open water channel in this study. We found two facts as follows: the hollow on the top of an apple plays reduction of width of the wake of an apple and reason of increasing the wake width is the flow separation from peripheral edge of the bagging.
Boardman, Carl; O'Callaghan, Kenneth; Delort, Anne-Marie; Song, Jim
2018-01-01
Plastic litter is encountered in aquatic ecosystems across the globe, including polar environments and the deep sea. To mitigate the adverse societal and ecological impacts of this waste, there has been debate on whether ‘biodegradable' materials should be granted exemptions from plastic bag bans and levies. However, great care must be exercised when attempting to define this term, due to the broad and complex range of physical and chemical conditions encountered within natural ecosystems. Here, we review existing international industry standards and regional test methods for evaluating the biodegradability of plastics within aquatic environments (wastewater, unmanaged freshwater and marine habitats). We argue that current standards and test methods are insufficient in their ability to realistically predict the biodegradability of carrier bags in these environments, due to several shortcomings in experimental procedures and a paucity of information in the scientific literature. Moreover, existing biodegradability standards and test methods for aquatic environments do not involve toxicity testing or account for the potentially adverse ecological impacts of carrier bags, plastic additives, polymer degradation products or small (microscopic) plastic particles that can arise via fragmentation. Successfully addressing these knowledge gaps is a key requirement for developing new biodegradability standard(s) for lightweight carrier bags. PMID:29892374
Field collection of Nasonia (parasitoid wasp) using baits.
Werren, John H; Loehlin, David W
2009-10-01
This protocol describes a standard method for collecting Nasonia wasps using "flyliver": liver remains fed upon by fly maggots (e.g., Sarcophaga) and collected after the mature larvae have dispersed. The flyliver, which contains a volatile substance that is very attractive to the wasps, is placed in a large (approximately 15-cm(2)) mesh bag hung in appropriate collection spots (e.g., near birds' nests or under culverts). Within the large mesh bag is a smaller mesh bag placed abutting the flyliver and containing four to six Sarcophaga pupae. These retain the wasps, which will enter the bag and begin stinging the hosts. The mesh bags can be made with standard nylon window screening, or any other material with mesh width large enough to permit entry of the wasps.
Relationship between Cognitive Impairment and Depression in Dialysis Patients
Jung, San; Choi, Sun Ryoung; Hwang, Sung-Hee; Noh, Jung-Woo
2013-01-01
Purpose Patients with chronic kidney disease frequently show cognitive dysfunction. The association of depression and cognitive function is not well known in maintenance dialysis patients. We evaluated cognitive impairment and depression, as well as their relationship in regards to methods of dialysis, maintenance hemodialysis (MHD) and chronic peritoneal dialysis (CPD). Materials and Methods Fifty-six maintenance dialysis patients were recruited and their clinical and laboratory data were collected. The Korean version of the mini-mental state exam (K-MMSE) was applied to screen the patient's cognitive function, while the Korean version of the Beck Depression Inventory (K-BDI) was used for depression screening. Results The average age of the participants was 54.2±10.2 years; 29 (51.8%) were female. The average dialysis vintage was 4.2±3.8 years. The CPD group showed significantly higher K-MMSE score (27.8±2.9 vs. 26.1±3.1, p=0.010) and lower K-BDI score (12.0±8.4 vs. 20.2±10.4, p=0.003) compared with the MHD group. The percentage of patients with depression symptoms was higher in the MHD group (51.7% vs. 18.5%). There was a negative correlation between cognitive function and prevalence of depressive symptoms. Depression and education level were shown to be independent predictors for cognitive impairment in multivariate analysis. Conclusion Cognitive impairment was closely correlated with depression. It is important to detect cognitive impairment and depression early in maintenance dialysis patients with simple bedside screening tools. PMID:24142650
The impact on quality of life of dialysis patients with renal insufficiency
Dąbrowska-Bender, Marta; Dykowska, Grażyna; Żuk, Wioletta; Milewska, Magdalena; Staniszewska, Anna
2018-01-01
Aim The aim of the study was the subjective assessment of the quality of life (QoL) of 140 patients treated with dialysis (peritoneal dialysis and hemodialysis). Background Chronic kidney disease and the methods of its treatment play an important part in shaping the QoL of patients receiving dialysis. As a result, kidney failure causes many limitations in patients’ physical, mental, and social activities. Methods The instrument to measure the QoL was the authors’ own questionnaire made on the basis of Kidney Disease and Quality of Life Short Form version 1.2 (KDQOL – SF 1.2) and their selection of areas influencing the perceived QoL of chronically ill patients. Results The research showed that patients receiving peritoneal dialysis assessed their QoL in its different dimensions as much higher than patients receiving hemodialysis. The parameter having the biggest negative impact on the QoL of patients receiving hemodialysis was an impeded possibility to continue work or studies and a change of life plans. The will to live was more highly assessed by patients receiving peritoneal dialysis as compared to patients receiving hemodialysis. Conclusion In order to improve the functioning of hemodialysis patients in a manner most similar to healthy persons, the renal replacement therapy should consider patients’ individual needs and expectations, ie, guarantee flexible hours of work or study and of receiving dialysis. In addition, patients treated with hemodialysis should receive psychological care, in particular those demonstrating emotional problems, in order to achieve better results in therapy and improve their QoL. PMID:29720873
High sensitivity pyrogen testing in water and dialysis solutions.
Daneshian, Mardas; Wendel, Albrecht; Hartung, Thomas; von Aulock, Sonja
2008-07-20
The dialysis patient is confronted with hundreds of litres of dialysis solution per week, which pass the natural protective barriers of the body and are brought into contact with the tissue directly in the case of peritoneal dialysis or indirectly in the case of renal dialysis (hemodialysis). The components can be tested for living specimens or dead pyrogenic (fever-inducing) contaminations. The former is usually detected by cultivation and the latter by the endotoxin-specific Limulus Amoebocyte Lysate Assay (LAL). However, the LAL assay does not reflect the response of the human immune system to the wide variety of possible pyrogenic contaminations in dialysis fluids. Furthermore, the test is limited in its sensitivity to detect extremely low concentrations of pyrogens, which in their sum result in chronic pathologies in dialysis patients. The In vitro Pyrogen Test (IPT) employs human whole blood to detect the spectrum of pyrogens to which humans respond by measuring the release of the endogenous fever mediator interleukin-1beta. Spike recovery checks exclude interference. The test has been validated in an international study for pyrogen detection in injectable solutions. In this study we adapted the IPT to the testing of dialysis solutions. Preincubation of 50 ml spiked samples with albumin-coated microspheres enhanced the sensitivity of the assay to detect contaminations down to 0.1 pg/ml LPS or 0.001 EU/ml in water or saline and allowed pyrogen detection in dialysis concentrates or final working solutions. This method offers high sensitivity detection of human-relevant pyrogens in dialysis solutions and components.
Natural disasters and dialysis care in the Asia-Pacific.
Gray, Nicholas A; Wolley, Martin; Liew, Adrian; Nakayama, Masaaki
2015-12-01
The impact of natural disasters on the provision of dialysis services has received increased attention in the last decade following Hurricane Katrina devastating New Orleans in 2005. The Asia-Pacific is particularly vulnerable to earthquakes, tsunami, typhoons (also known as cyclones and hurricanes) or storms and flooding. These events can seriously interrupt provision of haemodialysis with adverse effects for patients including missed dialysis, increased hospitalization and post-traumatic stress disorder. Furthermore, haemodialysis patients may need to relocate and experience prolonged periods of displacement from family and social supports. In contrast to haemodialysis, most literature suggests peritoneal dialysis in a disaster situation is more easily managed and supported. It has become apparent that dialysis units and patients should be prepared for a disaster event and that appropriate planning will result in reduced confusion and adverse outcomes should a disaster occur. Numerous resources are now available to guide dialysis units, patients and staff in preparation for a possible disaster. This article will examine the disaster experiences of dialysis units in the Asia-Pacific, the impact on patients and staff, methods employed to manage during the disaster and suggested plans for reducing the impact of future disasters. © 2015 Asian Pacific Society of Nephrology.
Solid and Liquid Waste Drying Bag
NASA Technical Reports Server (NTRS)
Litwiller, Eric (Inventor); Hogan, John A. (Inventor); Fisher, John W. (Inventor)
2009-01-01
Method and system for processing waste from human activities, including solids, liquids and vapors. A fluid-impermeable bag, lined with a liquid-impermeable but vapor-permeable membrane, defining an inner bag, is provided. A vacuum force is provided to extract vapors so that the waste is moved toward a selected region in the inner bag, extracted vapors, including the waste vapors and vaporized portions of the waste liquids are transported across the membrane, and most or all of the solids remain within the liner. Extracted vapors are filtered, and sanitized components thereof are isolated and optionally stored. The solids remaining within the liner are optionally dried and isolated for ultimate disposal.
Bioactive glass fillers reduce bacterial penetration into marginal gaps for composite restorations
Khvostenko, D.; Hilton, T. J.; Ferracane, J. L.; Mitchell, J. C.; Kruzic, J. J.
2015-01-01
Objectives Bioactive glass (BAG) is known to possess antimicrobial and remineralizing properties; however, the use of BAG as a filler for resin based composite restorations to slow recurrent caries has not been studied. Accordingly, the objective of this study was to investigate the effect of 15 wt% BAG additions to a resin composite on bacterial biofilms penetrating into marginal gaps of simulated tooth fillings in vitro during cyclic mechanical loading. Methods Human molars were machined into approximately 3 mm thick disks of dentin and 1.5–2 mm deep composite restorations were placed. A narrow 15–20 micrometer wide dentin-composite gap was allowed to form along half of the margin by not applying dental adhesive to that region. Two different 72 wt% filled composites were used, one with 15 wt% BAG filler (15BAG) and the balance silanated strontium glass and one filled with OX-50 and silanated strontium glass without BAG (0BAG – control). Samples of both groups had Streptococcus mutans biofilms grown on the surface and were tested inside a bioreactor for two weeks while subjected to periods of cyclic mechanical loading. After post-test biofilm viability was confirmed, each specimen was fixed in glutaraldehyde, gram positive stained, mounted in resin and cross-sectioned to reveal the gap profile. Depth of biofilm penetration for 0BAG and 15BAG was quantified as the fraction of gap depth. The data were compared using a Student’s t-test. Results The average depth of bacterial penetration into the marginal gap for the 15BAG samples was significantly smaller (~61%) in comparison to 0BAG, where 100% penetration was observed for all samples with the biofilm penetrating underneath of the restoration in some cases. Significance BAG containing resin dental composites reduce biofilm penetration into marginal gaps of simulated tooth restorations. This suggests BAG containing composites may have the potential to slow the development and propagation of secondary tooth decay at restoration margins. PMID:26621028
Knezevic, Tijana; Myers, Valerie D.; Su, Feifei; Wang, JuFang; Song, Jianliang; Zhang, Xue-Qian; Gao, Erhe; Gao, Guofeng; Muniswamy, Madesh; Gupta, Manish K.; Gordon, Jennifer; Weiner, Kristen N.; Rabinowitz, Joseph; Ramsey, Frederick V.; Tilley, Douglas G.; Khalili, Kamel; Cheung, Joseph Y.; Feldman, Arthur M.
2016-01-01
Objectives The present study was undertaken to test the hypothesis that gene delivery of BCL2-Associated Athanogene 3 (BAG3) to the heart of mice with left ventricular dysfunction secondary to a myocardial infarction could enhance cardiac performance. Background BAG3 is a 575 amino acid protein that has pleotropic functions in the cell including pro-autophagy and anti-apoptosis. Mutations in BAG3 have been associated with both skeletal muscle dysfunction and familial dilated cardiomyopathy and BAG3 levels are diminished in non-familial heart failure. Methods Eight-week-old C57/BL6 mice underwent ligation of the left coronary artery (MI) or sham surgery (Sham). Eight weeks later, mice in both groups were randomly assigned to receive either a retro-orbital injection of rAAV9-BAG3 (MI-BAG3 or Sham-BAG3) or rAAV9-GFP (MI-GFP or Sham GFP). Mice were sacrificed at 3 weeks post-injection and myocytes were isolated from the left ventricle. Results MI-BAG3 mice demonstrated a significantly (p < 0.0001) higher left ventricular ejection fraction (LVEF) 9 days after rAAV9-BAG3 injection with further improvement in LVEF, fractional shortening and stroke volume at 3 weeks post-injection without changes in LV mass or LV volume. Injection of rAAV9-BAG3 had no effect on LVEF in Sham mice. The salutary benefits of rAAV9-BAG3 were also observed in myocytes isolated from MI hearts including improved cell shortening (p<0.05), increased systolic [Ca2+]i, increased [Ca2+]i transient amplitudes and increased maximal ICa amplitude. Implications The results suggest that BAG3 gene therapy may provide a novel therapeutic option for the treatment of heart failure. PMID:28164169
Hemodialysis Reliable Outflow (HeRO) device in end-stage dialysis access: a decision analysis model.
Dageforde, Leigh Anne; Bream, Peter R; Moore, Derek E
2012-09-01
The Hemodialysis Reliable Outflow (HeRO) dialysis access device is a permanent tunneled dialysis graft connected to a central venous catheter and is used in patients with end-stage dialysis access (ESDA) issues secondary to central venous stenosis. The safety and effectiveness of the HeRO device has previously been proven, but no study thus far has compared the cost of its use with tunneled dialysis catheters (TDCs) and thigh grafts in patients with ESDA. A decision analytic model was developed to simulate outcomes for patients with ESDA undergoing placement of a HeRO dialysis access device, TDC, or thigh graft. Outcomes of interest were infection, thrombosis, and ischemic events. Baseline values, ranges, and costs were determined from a systematic review of the literature. Total costs were based on 1 year of post-procedure outcomes. Sensitivity analyses were conducted to test model strength. The HeRO dialysis access device is the least costly dialysis access with an average 1-year cost of $6521. The 1-year cost for a TDC was $8477. A thigh graft accounted for $9567 in a 1-year time period. The HeRO dialysis access device is the least costly method of ESDA. The primary determinants of cost in this model are infection in TDCs and leg ischemia necessitating amputation in thigh grafts. Further study is necessary to incorporate patient preference and quality of life into the model. Copyright © 2012 Elsevier Inc. All rights reserved.
Wang, Jhi-Joung; Weng, Shih-Feng; Lin, Chih-Ching; Chien, Chih-Chiang
2017-01-01
Background Patients with advanced diabetic kidney disease (DKD) behave differently to diabetic patients without kidney disease. We aimed to investigate the associations of hypoglycemia and outcomes after initiation of dialysis in patients with advanced DKD on dialysis. Methods Using National Health Insurance Research Database, 20,845 advanced DKD patients beginning long-term dialysis between 2002 and 2006 were enrolled. We investigated the incidence of severe hypoglycemia episodes before initiation of dialysis. Patients were followed from date of first dialysis to death, end of dialysis, or 2008. Main outcomes measured were all-cause mortality, myocardial infarction (MI), and subsequent severe hypoglycemic episodes after dialysis. Results 19.18% patients had at least one hypoglycemia episode during 1-year period before initiation of dialysis. Advanced DKD patients with higher adapted Diabetes Complications Severity Index (aDCSI) scores were associated with more frequent hypoglycemia (P for trend < 0.001). Mortality and subsequent severe hypoglycemia after dialysis both increased with number of hypoglycemic episodes. Compared to those who had no hypoglycemic episodes, those who had one had a 15% higher risk of death and a 2.3-fold higher risk of subsequent severe hypoglycemia. Those with two or more episodes had a 19% higher risk of death and a 3.9-fold higher risk of subsequent severe hypoglycemia. However, previous severe hypoglycemia was not correlated with risk of MI after dialysis. Conclusions The rate of severe hypoglycemia was high in advanced DKD patients. Patients with higher aDCSI scores tended to have more hypoglycemic episodes. Hypoglycemic episodes were associated with subsequent hypoglycemia and mortality after initiation of dialysis. We studied the associations and further study is needed to establish cause. In addition, more attention is needed for hypoglycemia prevention in advanced DKD patients, especially for those at risk patients. PMID:28355264
Comparison of three chronic dialysis models.
Peng, W X; Guo, Q Y; Liu, S M; Liu, C Z; Lindholm, B; Wang, T
2000-01-01
The chronic peritoneal dialysis model is important for understanding the pathophysiology of peritoneal transport and for studying biocompatibility of peritoneal dialysis solutions. In this study, we compared three different chronic peritoneal dialysis models. A peritoneal catheter was placed in 23 male Sprague-Dawley rats, 12 of which had an intact omentum (model 1) and 11 of which received an omentectomy (model 2). Seven other rats, without a catheter, received a daily intraperitoneal injection (model 3). Each rat received a daily infusion of 25 mL of 3.86% glucose dialysis solution either through the catheter (models 1 and 2) or through injection (model 3) for 4 weeks. Then, a 4-hour dwell study using 3.86% glucose solution with an intraperitoneal volume marker and frequent dialysate and blood sampling was performed in each rat. The intraperitoneal volume was significantly lower in all the dialysis groups as compared to a control group (n = 6) in which the rats had no chronic dialysate exposure. The peritoneal fluid absorption rate, as well as the direct lymphatic absorption rate, was significantly higher in the three dialysis groups as compared to the control group. In general, no significant differences were seen in any of the parameters among the three dialysis models. Owing to catheter obstruction, three rats in model 1 and four rats in model 2 were lost during dialysis. Histological examination showed no significant differences among the three dialysis groups. Our results suggest that omentectomy may not be necessary in the chronic peritoneal dialysis model when using dialysate infusion and no drainage. Based on the present study, we think that perhaps model 1 may be the method of choice to test new peritoneal dialysis solutions. However, owing to its simplicity, model 3 could also be used if great care is taken to avoid puncturing the intestine or injecting into the abdominal wall.
Spatial Analysis of Case-Mix and Dialysis Modality Associations
Phirtskhalaishvili, Tamar; Bayer, Florian; Edet, Stephane; Bongiovanni, Isabelle; Hogan, Julien; Couchoud, Cécile
2016-01-01
♦ Background: Health-care systems must attempt to provide appropriate, high-quality, and economically sustainable care that meets the needs and choices of patients with end-stage renal disease (ESRD). France offers 9 different modalities of dialysis, each characterized by dialysis technique, the extent of professional assistance, and the treatment site. The aim of this study was 1) to describe the various dialysis modalities in France and the patient characteristics associated with each of them, and 2) to analyze their regional patterns to identify possible unexpected associations between case-mixes and dialysis modalities. ♦ Methods: The clinical characteristics of the 37,421 adult patients treated by dialysis were described according to their treatment modality. Agglomerative hierarchical cluster analysis was used to aggregate the regions into clusters according to their use of these modalities and the characteristics of their patients. ♦ Result: The gradient of patient characteristics was similar from home hemodialyis (HD) to in-center HD and from non-assisted automated peritoneal dialysis (APD) to assisted continuous ambulatory peritoneal dialysis (CAPD). Analyzing their spatial distribution, we found differences in the patient case-mix on dialysis across regions but also differences in the health-care provided for them. The classification of the regions into 6 different clusters allowed us to detect some unexpected associations between case-mixes and treatment modalities. ♦ Conclusions: The 9 modalities of treatment available make it theoretically possible to adapt treatment to patients' clinical characteristics and abilities. However, although we found an overall appropriate association of dialysis modalities to the case-mix, major inter-region heterogeneity and the low rate of peritoneal dialysis (PD) and home HD suggest that factors besides patients' clinical conditions impact the choice of dialysis modality. The French organization should now be evaluated in terms of patients' quality of life, satisfaction, survival, and global efficiency. PMID:26475843
Budowski-Tal, Inbal; Nov, Yuval; Kolodny, Rachel
2010-02-23
Fast identification of protein structures that are similar to a specified query structure in the entire Protein Data Bank (PDB) is fundamental in structure and function prediction. We present FragBag: An ultrafast and accurate method for comparing protein structures. We describe a protein structure by the collection of its overlapping short contiguous backbone segments, and discretize this set using a library of fragments. Then, we succinctly represent the protein as a "bags-of-fragments"-a vector that counts the number of occurrences of each fragment-and measure the similarity between two structures by the similarity between their vectors. Our representation has two additional benefits: (i) it can be used to construct an inverted index, for implementing a fast structural search engine of the entire PDB, and (ii) one can specify a structure as a collection of substructures, without combining them into a single structure; this is valuable for structure prediction, when there are reliable predictions only of parts of the protein. We use receiver operating characteristic curve analysis to quantify the success of FragBag in identifying neighbor candidate sets in a dataset of over 2,900 structures. The gold standard is the set of neighbors found by six state of the art structural aligners. Our best FragBag library finds more accurate candidate sets than the three other filter methods: The SGM, PRIDE, and a method by Zotenko et al. More interestingly, FragBag performs on a par with the computationally expensive, yet highly trusted structural aligners STRUCTAL and CE.
Bertolini, F; Battaglia, M; Zibera, C; Baroni, G; Soro, V; Perotti, C; Salvaneschi, L; Robustelli della Cuna, G
1996-10-01
We describe a new procedure for large-scale CB processing in the collection bag, thus minimizing the risk of CB contamination. A solution of 6% hydroxyethyl starch (HES) was added directly to the CB containing bag. After RBC sedimentation at 4 degrees C, the WBC-rich supernatant was collected in a satellite bag and centrifuged. After supernatant removal, the cell pellet was resuspended and the percent recovery of total WBC, CD34+ progenitor cells, CFU-GM and cobblestone area-forming cells (CAFC) evaluated. Results obtained with three different types of CB collection bags (300, 600 and 1000 ml) were analyzed and compared with those of an open system in 50 ml tubes. CB processing procedures in 300 and 1000 ml bags were associated with better WBC, CFU, CD34+ cell and CAFC recovery (83-93%). This novel CB processing procedure appears to be easy, effective and particularly suitable for large-scale banking under GMP conditions.
Bias of Tedlar bags in the measurement of agricultural odorants.
Trabue, Steven L; Anhalt, Jennifer C; Zahn, James A
2006-01-01
Odor regulations typically specify the use of dynamic dilution olfactometery (DDO) as a method to quantify odor emissions, and Tedlar bags are the preferred holding container for grab samples. This study was conducted to determine if Tedlar bags affect the integrity of sampled air from animal operations. Air samples were collected simultaneously in both Tedlar bags and Tenax thermal desorption tubes. Sample sources originated from either a hydrocarbon-free air tank, dynamic headspace chamber (DHC), or swine-production facility, and were analyzed by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). Several background contaminants were identified from Tedlar bags, which included the odorous compounds N,N-dimethyl acetamide (DMAC), acetic acid, and phenol. Samples from the DHC demonstrated that recovery of malodor compounds was dependent on residence time in the Tedlar bag with longer residence time leading to lower recovery. After 24 h of storage, recovery of C3-C6 volatile fatty acids (VFA) averaged 64%, 4-methylphenol and 4-ethylphenol averaged 10%, and indole and 3-methylindole were below the detection limits of GC-MS-O. The odor activity value (OAV) of grab samples collected in Tedlar bags were 33 to 65% lower following 24 h of storage. These results indicate that significant odorant bias occurs when using Tedlar bags for the sampling of odors from animal production facilities.
Plant Tissue Culture in a Bag.
ERIC Educational Resources Information Center
Beck, Mike
2000-01-01
Describes the use of an oven bag as a sterile chamber for culture initiation and tissue transfer. Plant tissue culture is an ideal tool for introducing students to plants, cloning, and experimental design. Includes materials, methods, discussion, and conclusion sections. (SAH)
Modesti, Marina; Pasqualitto, Giacomo; Appolloni, Rossella; Pecorella, Irene; Sourdille, Philippe
2011-10-01
To evaluate capsular bag size and accommodative movement before and after cataract surgery using ultrasound biomicroscopy (UBM) and anterior segment optical coherence tomography (AS-OCT). Ophthalmology Unit, Fabia Mater Clinic, Rome, Italy. Cohort study. Eyes having cataract surgery and monofocal intraocular lens (IOL) implantation were studied using UBM. The following parameters were measured preoperatively and 1, 2, and 12 months postoperatively: anterior chamber depth (ACD) (also by AS-OCT), capsular bag thickness, capsular bag diameter, ciliary ring diameter, sulcus-to-sulcus (STS) diameter, ciliary process-capsular bag distance, ciliary apex-capsular bag plane, and IOL tilting. The preoperative and postoperative capsular bag volumes were calculated at 12 months. The results were compared with the changes during accommodation. The study comprised 24 eyes. With the exception of the ciliary apex-capsular bag plane, which appeared to be unmodified postoperatively, all measured parameters showed significant variation after IOL implantation. Only the ACD did not change significantly during accommodation. After cataract surgery, the capsular bag stretched horizontally and with reduced vertical diameter as a result of adaptation to the implanted IOL. The capsular bag-IOL complex filled all available space, compressing the zonular fibers and almost abolishing the space between the ciliary apex and the capsular bag. There was anterior chamber deepening and a decrease in the ciliary ring diameter and STS diameter. In the absence of zonular fiber tension, the shape of the ciliary processes may be modified. No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Ion release from, and fluoride recharge of a composite with a fluoride-containing bioactive glass.
Davis, Harry B; Gwinner, Fernanda; Mitchell, John C; Ferracane, Jack L
2014-10-01
Materials that are capable of releasing ions such as calcium and fluoride, that are necessary for remineralization of dentin and enamel, have been the topic of intensive research for many years. The source of calcium has most often been some form of calcium phosphate, and that for fluoride has been one of several metal fluoride or hexafluorophosphate salts. Fluoride-containing bioactive glass (BAG) prepared by the sol-gel method acts as a single source of both calcium and fluoride ions in aqueous solutions. The objective of this investigation was to determine if BAG, when added to a composite formulation, can be used as a single source for calcium and fluoride ion release over an extended time period, and to determine if the BAG-containing composite can be recharged upon exposure to a solution of 5000ppm fluoride. BAG 61 (61% Si; 31% Ca; 4% P; 3% F; 1% B) and BAG 81 (81% Si; 11% Ca; 4% P; 3% F; 1% B) were synthesized by the sol-gel method. The composite used was composed of 50/50 Bis-GMA/TEGDMA, 0.8% EDMAB, 0.4% CQ, and 0.05% BHT, combined with a mixture of BAG (15%) and strontium glass (85%) to a total filler load of 72% by weight. Disks were prepared, allowed to age for 24h, abraded, then placed into DI water. Calcium and fluoride release was measured by atomic absorption spectroscopy and fluoride ion selective electrode methods, respectively, after 2, 22, and 222h. The composite samples were then soaked for 5min in an aqueous 5000ppm fluoride solution, after which calcium and fluoride release was again measured at 2, 22, and 222h time points. Prior to fluoride recharge, release of fluoride ions was similar for the BAG 61 and BAG 81 composites after 2h, and also similar after 22h. At the four subsequent time points, one prior to, and three following fluoride recharge, the BAG 81 composite released significantly more fluoride ions (p<0.05). Both composites were recharged by exposure to 5000ppm fluoride, although the BAG 81 composite was recharged more than the BAG 61 composite. The BAG 61 composite released substantially more calcium ions prior to fluoride recharge during each of the 2 and 22h time periods. Thereafter, the release of calcium at the four subsequent time points was not significantly different (p>0.05) for the two composites. These results show that, when added to a composite formulation, fluoride-containing bioactive glass made by the sol-gel route can function as a single source for both calcium and fluoride ions, and that the composite can be readily recharged with fluoride. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Is the Capsular Bag Perimeter Round or Elliptical?
Amigó, Alfredo; Bonaque-González, Sergio
2016-01-01
Purpose: To report findings that could suggest an elliptical shape of the capsular bag. Methods: Five eyes of three patients with axial length greater than 24 mm underwent phacoemulsification cataract surgery with plate-haptic multifocal toric intraocular lens (IOL) implantation oriented in the vertical meridian. Results: In all cases, correct orientation of the IOLs was verified 30 minutes after surgery. After 24 hours, all eyes demonstrated unwanted rotation of the IOLs ranging from 15 to 45 degrees. The IOLs remained stable in the new position in all cases until adhesion of the capsular bag took place. Conclusion: These observations could suggest that the perimeter of the capsular bag has an elliptical shape. Therefore, the IOL tends to become fixated in a meridian of the capsular bag that best fits the diagonal diameter of the IOL. PMID:27413495
Advantages and disadvantages of surgical placement of PD catheters with regard to other methods.
Stegmayr, B
2006-01-01
Peritoneal dialysis is underused for various reasons. One reason may be problems with insertion of catheters for access. Another reason is the delayed start (break-in period) of about 2 weeks after operation. This review describes various approaches to the insertion of a peritoneal dialysis catheter. The optimal conditions to strive for are given as is an overview of various techniques. This article favours surgical placement while others might prefer other techniques. Described is the use a 3-purse string suture technique that allows immediate start of dialysis after catheter insertion both for acute dialysis indications as well as for acute start in chronic dialysis patients. A key to lesser complications is to establish a team devoted to the insertions rather than to allow various physicians to perform insertions as a training procedure. An optimal access is one of the important life lines for these patients.
Performance of distributed bagged stone dust barrier in combating coal-dust explosions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Plessis, J.J.L. du; Vassard, P.S.
1999-07-01
The Kloppersbos Research Facility of the CSIR's Division of Mining Technology has developed a new method of building stone dust barriers. The new barrier makes use of a previous concept of containing stone dust in a bag, but incorporates a new method of rupturing the bag. This was achieved by adapting the closing mechanism and by balancing the stone dust content with the void in the bag. The bagged barrier was extensively tested in the 200-m test gallery. During these tests, it became evident that these bags could be made to rupture and spread stone dust when subjected to smallermore » forces than those required for the most commonly used passive barrier, the Polish light barrier. To validate this, as well as to gain international acceptance of this new barrier, tests were conducted in the German experimental mine, DMT Tremonia, Dortmund. The barrier was evaluated against numerous methane-initiated coal-dust explosions. The paper describes the successful inhibition of coal-dust explosions at Kloppersbos and DMT tremonia. The barrier has been proven successfully for static pressures of 44 to 82 kpa, dynamic pressures of 12 to 36 kpa and for flame speeds as low as 23 m/s. This barrier is now accepted by the South African government and has been implemented in numerous South African collieries.« less
Homocystein as a Risk Factor for Developing Complications in Chronic Renal Failure
Jakovljevic, Biljana; Gasic, Branislav; Kovacevic, Pedja; Rajkovaca, Zvezdana; Kovacevic, Tijana
2015-01-01
Aim: Cardiovascular diseases are leading cause of death in patients with chronic renal failure. The aim of our study was to establish connection between levels of homocysteine and traditional and nontraditional risk factors for developing cardiovascular diseases in dialysis and pre dialysis patients. Methods: We included 33 pre dialysis (23 in stage three and 10 in stage four of chronic kidney disease) and 43 patients receiving hemodialysis longer than six months. Besides standard laboratory parameters, levels of homocysteine and blood pressure were measured in all patients. Glomerular filtration rate was measured in pre dialysis patients and dialysis quality parameters in dialysis patients. Results: Homocysteine levels were elevated in all patients (19±5.42mmol/l). The connection between homocysteine levels and other cardiovascular diseases risk factors was not established in pre dialysis patients. In patients treated with hemodialysis we found negative correlation between homocysteine levels and patients’ age (p<0.05) and positive correlation between homocysteine levels and length of dialysis (p<0.01) as well as between homocysteine and anemia parameters (erythrocytes, hemoglobin), (p<0.01). Homocysteine and LDL (and total cholesterol) were in negative correlation (p<0.01). Conclusion: Homocysteine, as one of nontraditional cardiovascular diseases risk factors, is elevated in all patients with chronic renal failure and it’s positive correlation with some other risk factors was found. PMID:26005384
Vangaveti, Venkat N.
2016-01-01
Background. Renal dialysis has recently been recognised as a risk factor for lower limb amputation (LLA). However, exact rates and associated risk factors for the LLA are incompletely understood. Aim. Prevalence and risk factors of LLA in end-stage renal failure (ESRF) subjects on renal dialysis were investigated from the existing literature. Methods. Published data on the subject were derived from MEDLINE, PubMed, and Google Scholar search of English language literature from January 1, 1980, to July 31, 2015, using designated key words. Results. Seventy studies were identified out of which 6 full-text published studies were included in this systematic review of which 5 included patients on haemodialysis alone and one included patients on both haemodialysis and peritoneal dialysis. The reported findings on prevalence of amputation in the renal failure on dialysis cohort ranged from 1.7% to 13.4%. Five out of the six studies identified diabetes as the leading risk factor for amputation in subjects with ESRF on renal dialysis. Other risk factors identified were high haemoglobin A1c, elevated c-reactive protein, and low serum albumin. Conclusions. This review demonstrates high rate of LLA in ESRF patients receiving dialysis therapy. It has also identified diabetes and markers of inflammation as risk factors of amputation in ESRF subjects on dialysis. PMID:27529033
de Abreu, Letícia Coli Louvisse; Todaro, Valerio; Sathler, Plinio Cunha; da Silva, Luiz Cláudio Rodrigues Pereira; do Carmo, Flávia Almada; Costa, Cleonice Marques; Toma, Helena Keiko; Castro, Helena Carla; Rodrigues, Carlos Rangel; de Sousa, Valeria Pereira; Cabral, Lucio Mendes
2016-12-01
The aim of this work was the development and characterization of nisin-loaded nanoparticles and the evaluation of its potential antifungal activity. Candidiasis is a fungal infection caused by Candida sp. considered as one of the major public health problem currently. The discovery of antifungal agents that present a reduced or null resistance of Candida sp. and the development of more efficient drug release mechanisms are necessary for the improvement of candidiasis treatment. Nisin, a bacteriocin commercially available for more than 50 years, exhibits antibacterial action in food products with potential antifungal activity. Among several alternatives used to modulate antifungal activity of bacteriocins, polymeric nanoparticles have received great attention due to an effective drug release control and reduction of therapeutic dose, besides the minimization of adverse effects by the preferential accumulation in specific tissues. The nisin nanoparticles were prepared by double emulsification and solvent evaporation methods. Nanoparticles were characterized by dynamic light scattering, zeta potential, Fourier transform infrared, X-ray diffraction, differential scanning calorimetry, and scanning electron microscopy. Antifungal activity was accessed by pour plate method and cell counting using Candida albicans strains. The in vitro release profile and in vitro permeation studies were performed using dialysis bag method and pig vaginal mucosa in Franz diffusion cell, respectively. The results revealed nisin nanoparticles (300 nm) with spherical shape and high loading efficiency (93.88 ± 3.26%). In vitro test results suggest a promising application of these nanosystems as a prophylactic agent in recurrent vulvovaginal candidiasis and other gynecological diseases.
Kim, Hyung Jong; Park, Jung Tak; Han, Seung Hyeok; Yoo, Tae-Hyun; Park, Hyeong-Cheon; Kang, Shin-Wook; Kim, Kyoung Hoon; Ryu, Dong-Ryeol; Kim, Hyunwook
2017-01-01
Background/Aims Since comorbidities are major determinants of modality choice, and also interact with dialysis modality on mortality outcomes, we examined the pattern of modality choice according to comorbidities and then evaluated how such choices affected mortality in incident dialysis patients. Methods We analyzed 32,280 incident dialysis patients in Korea. Patterns in initial dialysis choice were assessed by multivariate logistic regression analyses. Multivariate Poisson regression analyses were performed to evaluate the effects of interactions between comorbidities and dialysis modality on mortality and to quantify these interactions using the synergy factor. Results Prior histories of myocardial infarction (p = 0.031), diabetes (p = 0.001), and congestive heart failure (p = 0.003) were independent factors favoring the initiation with peritoneal dialysis (PD), but were associated with increased mortality with PD. In contrast, a history of cerebrovascular disease and 1-year increase in age favored initiation with hemodialysis (HD) and were related to a survival benefit with HD (p < 0.001, both). While favoring initiation with HD, having Medical Aid (p = 0.001) and male gender (p = 0.047) were related to increased mortality with HD. Furthermore, although the severity of comorbidities did not inf luence dialysis modality choice, mortality in incident PD patients was significantly higher compared to that in HD patients as the severity of comorbidities increased (p for trend < 0.001). Conclusions Some comorbidities exerted independent effects on initial choice of dialysis modality, but this choice did not always lead to the best results. Further analyses of the pattern of choosing dialysis modality according to baseline comorbid conditions and related consequent mortality outcomes are needed. PMID:28651309
2013-01-01
Background Vascular calcification (VC) and carotid intima media thickness (CIMT) are strongly associated with cardiovascular (CV) disease. We hypothesized that significant VC on plain radiographs is associated with CIMT and CV events in dialysis patients. In addition, we evaluated risk factors for VC progression on plain radiographs in dialysis patients. Methods In this 2-year observational, prospective study, 67 dialysis patients were included. We checked plain radiographs at baseline and after 2 years. Laboratory tests and malnutrition score were obtained at baseline, after 12 months, and after 24 months. Results The mean age of patients was 56.3 ± 10.3 years and duration of dialysis was 41.3 ± 34.5 months. The prevalence of significant VC was 61.2% and the prevalence of carotid artery atheromatous plaques was 55.6%. Mean CIMT, malnutrition scores, CRP level and prevalence of carotid atheromatous plaques were significantly higher in patients with significant VC. Serum albumin and total iron binding capacity were significantly lower in patients with significant VC compared to patients without significant VC. During a mean observational period of 22 months, patients without significant VC showed lower CV events by the Kaplan-Meyer method (p = 0.010). Progression of VC was found in 35.7% among 56 patients followed up. Hemoglobin after 24 months was an independent factor for progression of VC (Exp(B) = 0.344, 95% Confidence Interval = 0.13 – 0.96, p = 0.034). Conclusions Significant VC on plain radiograph was associated with CIMT, malnutrition, inflammation, and CV events in dialysis patients. Conditions which increase hemoglobin level may retard progression of VC in dialysis patients. PMID:23360132
A new method to evaluate patient characteristic response to ultrafiltration during hemodialysis.
Casagrande, G; Teatini, U; Romei Longhena, G; Miglietta, F; Fumero, R; Costantino, M L
2007-05-01
Several factors are involved in the pathogenesis of dialysis discomfort interfering with optimal fluid removal and reducing the efficacy of the treatment; the most important one is a decrease in blood volume caused by an imbalance between ultrafiltration (UF) and plasmarefilling (PR) rates. This study is aimed at devising a method to tailor the dialysis therapy to each individual patient, by analyzing the relationship between PR and UF during the sessions in stable patients and widening the knowledge of fluid exchanges during the treatment. Thirty stable patients undergoing maintenance hemodialysis were enrolled. Three dialysis sessions were monitored for each patient; systemic pressure, blood composition, blood volume % variation, weight loss and conductivity were recorded repeatedly. A Plasma Refilling Index (PRI), defined and calculated by means of parameters measured throughout the dialysis, was introduced as a novel instrument to study plasma refilling phenomena. Results. The PRI provides understanding of patient response (in terms of plasma refilling) to the set UF. In the monitored sessions, the PRI trend is found to be characteristic of each patient; a PRI course that is at variance with the characteristic trend is a signal of inadequate or unusual dialysis scheduling. Moreover, statistical analysis highlights two different PRI trends during the first hour and during the rest of the treatment, suggesting the presence of different treatment phases. The main advantage of the PRI index is that it is non-invasive peculiar to each patient and easy to compute in a dialysis routine based on online data recorded by the monitor. A deviation from the characteristic trend may be a warning for the clinician. The analysis of the PRI trend also suggests how to modulate UF as a function of interstitial to intravascular fluid removal balance during dialysis.
Koefoed, Mette; Kromann, Charles Boy; Juliussen, Sophie Ryberg; Hvidtfeldt, Danni; Ekelund, Bo; Frandsen, Niels Erik; Marckmann, Peter
2016-01-01
Background and Aims Maintenance dialysis patients are at increased risk of abnormal nutritional status due to numerous causative factors, both nutritional and non-nutritional. The present study assessed the current prevalence of protein-energy wasting, low lean body mass index and obesity in maintenance dialysis patients, and compared different methods of nutritional assessment. Methods In a cross-sectional study conducted in 2014 at Roskilde Hospital, Denmark, we performed anthropometry (body weight, skinfolds, mid-arm, waist, and hip circumferences), and determined plasma albumin and normalized protein catabolic rate in order to assess the prevalence of protein-energy wasting, low lean body mass index and obesity in these patients. Results Seventy-nine eligible maintenance dialysis patients participated. The prevalence of protein-energy wasted patients was 4% (95% CI: 2–12) as assessed by the coexistence of low lean body mass index and low fat mass index. Low lean body mass index was seen in 32% (95% CI: 22–44). Obesity prevalence as assessed from fat mass index was 43% (95% CI: 32–55). Coexistence of low lean body mass index and obesity was seen in 10% (95% CI: 5–19). The prevalence of protein-energy wasting and obesity varied considerably, depending on nutritional assessment methodology. Conclusions Our data indicate that protein-energy wasting is uncommon, whereas low lean body mass index and obesity are frequent conditions among patients in maintenance dialysis. A focus on how to increase and preserve lean body mass in dialysis patients is suggested in the future. In order to clearly distinguish between shortage, sufficiency and abundance of protein and/or fat deposits in maintenance dialysis patients, we suggest the simple measurements of lean body mass index and fat mass index. PMID:26919440
Measurement of the postruminal digestibility of crude protein by the bag technique in cows.
Voigt, J; Piatkowski, B; Engelmann, H; Rudolph, E
1985-08-01
A new method has been developed which permits the crude protein digestibility of feedstuffs in the intestine of cattle to be measured with little effort in terms of samples and experimental work. It consists of welding 0.4 ... 0.8 g of the feedstuff (particle size: 125 ... 1000 micron) into polyamide fabric bags (25 X 40 mm) which are inserted via cannulae into the digestive tracts of fistulated cows from the abomasum/duodenum to the ileum or from the abomasum/duodenum to the faeces. The mean retention time of the bags in the animal was 8.5 +/- 2.7 h from the abomasum to the end of the ileum and (13.3 +/- 1.9 h from the abomasum to the faeces. Up to 15 bags per day and cow may be used. The random error of the method is 1.3% (absolute) when the measurements are performed on two animals using two bags each. Intestinal digestibilities of over 90% were measured for concentrate proteins (except linseed meal) and of 72 ... 95% for forage proteins. Post-ruminal digestion was virtually finished at the end of the small intestine.
NEAL, PAUL R.; ANDERSON, GREGORY J.
2004-01-01
• Background and Aims Fabrics used in pollination bags may exclude pollen carried by biotic vectors, but have varying degrees of permeability to wind‐borne pollen. The permeability of bags to wind‐borne pollen may have important consequences in studies of pollination and reproductive biology. The permeability of four fabrics commonly used in the construction of pollination bags was examined. • Methods Deposition of wind‐borne pollen on horizontally and vertically oriented microscope slides was assessed on slides enclosed in pollination bags, as well as on control slides. • Key Results It was found that the permeability of fabrics to wind‐borne pollen, as measured by deposition on both horizontally and vertically oriented slides, decreased with pore size. However, deposition on horizontal slides was always greater than on vertical slides for a given fabric; this could manifest itself as differential success of pollination of flowers in bags—dependent on flower orientation. • Conclusions Obviously, bags with mesh size smaller than most pollen grains are impermeable to pollen. However, material for such bags is very expensive. In addition, it was also observed that bags with even moderately small pore size, such as pores (approx. 200 µm) in twisted fibre cotton muslin, offered highly significant barriers to passage of wind‐borne pollen. Such bags are sufficiently effective in most large‐sample‐size reproductive biology studies. PMID:15037446
Selvi, Emine Kılıçkaya; Şahin, Uğur; Şahan, Serkan
2017-01-01
This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosphate. The analytical parameters that influenced the quantitative coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte ion were in the range of 95-105 % with limit of detection (3s) of 0.5 µg l -1 . Preconcentration factor was found as 1000 and Relative Standard Deviation (RSD) % value obtained from model solutions was 2.5% for 0.02 mg L -1 . The accuracy of the method was evaluated with standard reference material (CWW-TMD Waste Water). The method was also applied to most concentrated acidic and basic dialysis concentrates with satisfactory results.
SHAHRYARI, Ali; NIKAEEN, Mahnaz; HATAMZADEH, Maryam; VAHID DASTJERDI, Marzieh; HASSANZADEH, Akbar
2016-01-01
Background: Chemical and microbial quality of water used in hemodialysis play key roles in a number of dialysis-related complications. In order to avoid the complications and to guarantee safety and health of patients therefore, vigorous control of water quality is essential. The objective of present study was to investigate the chemical and bacteriological characteristics of water used in dialysis centers of five hospitals in Isfahan, central Iran. Methods: A total of 30 water samples from the input of dialysis purification system and dialysis water were analyzed for chemical parameters. Heterotrophic plate count and endotoxin concentration of drinking water, dialysis water and dialysis fluid of 40 machines were also monitored over a 5-month period in 2011–2012. Results: Concentration of the determined chemicals (copper, zinc, sulfate, fluoride, chloramines and free chlorine) did not exceed the recommended concentration by the Association for the Advancement of Medical Instrumentation (AAMI) exclude lead, nitrate, aluminum and calcium. Furthermore, the magnesium; cadmium and chromium concentration exceeded the maximum level in some centers. No contamination with heterotrophic bacteria was observed in all samples, while the AMMI standard for endotoxin level in dialysis fluid (<2 EU/ml) was achieved in 95% of samples. Conclusion: Dialysis water and fluid failed to meet the all chemical and bacteriological requirements for hemodialysis. To minimize the risk of contaminants for hemodialysis patients therefore, a water quality management program including monitoring, maintenance and development of water treatment system in hemodialysis centers is extremely important. In addition, an appropriate disinfection program is needed to guarantee better control of bacterial growth and biofilm formation. PMID:27398338
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langer, Jessica M.; Cohen, Raphael M.; Berns, Jeffrey S.
Purpose: Over-the-wire exchange of tunneled dialysis catheters is the standard of care per K/DOQI guidelines for treating catheter-related bacteremia. However, Gram-positive bacteremia, specifically with staphylococcus species, may compromise over-the-wire exchange due to certain biological properties. This study addressed the effectiveness of over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters compared with non-staphylococcus-infected tunneled dialysis catheters. Methods: Patients who received over-the-wire exchange of their tunneled dialysis catheter due to documented or suspected bacteremia were identified from a QA database. Study patients (n = 61) had positive cultures for Staphylococcus aureus, Staphylococcus epidermidis, or coagulase-negative staphylococcus not otherwise specified. Control patients (n =more » 35) received over-the-wire exchange of their tunneled dialysis catheter due to infection with any organism besides staphylococcus. Overall catheter survival and catheter survival among staphylococcal species were assessed. Results: There was no difference in tunneled dialysis catheter survival between study and control groups (P = 0.46). Median survival time was 96 days for study catheters and 51 days for controls; survival curves were closely superimposed. There also was no difference among the three staphylococcal groups in terms of catheter survival (P = 0.31). The median time until catheter removal was 143 days for SE, 67 days for CNS, and 88 days for SA-infected catheters. Conclusions: There is no significant difference in tunneled dialysis catheter survival between over-the-wire exchange of staphylococcus-infected tunneled dialysis catheters and those infected with other organisms.« less
Kuttykrishnan, Sooraj; Kalantar-Zadeh, Kamyar; Arah, Onyebuchi A.; Cheung, Alfred K.; Brunelli, Steve; Heagerty, Patrick J.; Katz, Ronit; Molnar, Miklos Z.; Nissenson, Allen; Ravel, Vanessa; Streja, Elani; Himmelfarb, Jonathan; Mehrotra, Rajnish
2015-01-01
Background The Institute of Medicine has identified the comparative effectiveness of renal replacement therapies as a kidney-related topic among the top 100 national priorities. Given the importance of ensuring internal and external validity, the goal of this study was to identify potential sources of bias in observational studies that compare outcomes with different dialysis modalities. Methods This observational cohort study used data from the electronic medical records of all patients that started maintenance dialysis in the calendar years 2007–2011 and underwent treatment for at least 60 days in any of the 2217 facilities operated by DaVita Inc. Each patient was assigned one of six dialysis modalities for each 91-day period from the date of first dialysis (thrice weekly in-center hemodialysis (HD), peritoneal dialysis (PD), less-frequent HD, home HD, frequent HD and nocturnal in-center HD). Results Of the 162 644 patients, 18% underwent treatment with a modality other than HD for at least one 91-day period. Except for PD, patients started treatment with alternative modalities after variable lengths of treatment with HD; the time until a change in modality was shortest for less-frequent HD (median time = 6 months) and longest for frequent HD (median time = 15 months). Between 30 and 78% of patients transferred to another dialysis facility prior to change in modality. Finally, there were significant differences in baseline and time-varying clinical characteristics associated with dialysis modality. Conclusions This analysis identified numerous potential sources of bias in studies of the comparative effectiveness of dialysis modalities. PMID:25883196
Dialysis Facility Transplant Philosophy and Access to Kidney Transplantation in the Southeast
Gander, Jennifer; Browne, Teri; Plantinga, Laura; Pastan, Stephen O; Sauls, Leighann; Krisher, Jenna; Patzer, Rachel E
2015-01-01
Background Little is known about the impact of dialysis facility treatment philosophy on access to transplant. The aim of our study was to determine the relationship between dialysis facility transplant philosophy and facility-level access to kidney transplant waitlisting. Methods A 25-item questionnaire administered to Southeastern dialysis facilities (n=509) in 2012 captured facility transplant philosophy (categorized as “transplant is our first choice,” “transplant is a great option for some,” and “transplant is a good option, if the patient is interested”) .. Facility-level waitlisting and facility characteristics were obtained from the 2008-2011 Dialysis Facility Report. Multivariable logistic regression was used to examinethe association between dialysis facility transplant philosophy and facility waitlisting performance (dichotomized using the national median), where low performance was defined as less than 21.7% of dialysis patients waitlisted within a facility. Results Fewer than 25% (n=124) of dialysis facilities reported “transplant is our first option.” A total of 131 (31.4%) dialysis facilities in the Southeast were high-performing with respect to waitlisting. Adjusted analysis showed that facilities who reported “transplant is our first option” were twice (OR=2.0, 95% CI 1.0, 3.9) as likely to have high waitlisting performance compared to facilities who reported “transplant is a good option, if the patient is interested.” Conclusions Facilities with staff who had a more positive transplant philosophy were more likely to have better facility waitlisting performance. Future prospective studies are needed to further transplantation. PMID:26278585
Factors Affecting Hemodialysis Adequacy in Cohort of Iranian Patient with End Stage Renal Disease.
Shahdadi, Hosein; Balouchi, Abbas; Sepehri, Zahra; Rafiemanesh, Hosein; Magbri, Awad; Keikhaie, Fereshteh; Shahakzehi, Ahmad; Sarjou, Azizullah Arbabi
2016-08-01
There are many factors that can affect dialysis adequacy; such as the type of vascular access, filter type, device used, and the dose, and rout of erythropoietin stimulation agents (ESA) used. The aim of this study was investigating factors affecting Hemodialysis adequacy in cohort of Iranian patient with end stage renal disease (ESRD). This is a cross-sectional study conducted on 133 Hemodialysis patients referred to two dialysis units in Sistan-Baluchistan province in the cities of Zabol and Iranshahr, Iran. We have looked at, (the effects of the type of vascular access, the filter type, the device used, and the dose, route of delivery, and the type of ESA used) on Hemodialysis adequacy. Dialysis adequacy was calculated using kt/v formula, two-part information questionnaire including demographic data which also including access type, filter type, device used for hemodialysis (HD), type of Eprex injection, route of administration, blood groups and hemoglobin response to ESA were utilized. The data was analyzed using the SPSS v16 statistical software. Descriptive statistical methods, Mann-Whitney statistical test, and multiple regressions were used when applicable. The range of calculated dialysis adequacy is 0.28 to 2.39 (units of adequacy of dialysis). 76.7% of patients are being dialyzed via AVF and 23.3% of patients used central venous catheters (CVC). There was no statistical significant difference between dialysis adequacy, vascular access type, device used for HD (Fresenius and B. Braun), and the filter used for HD (p> 0.05). However, a significant difference was observed between the adequacy of dialysis and Eprex injection and patients' time of dialysis (p <0.05). Subcutaneous ESA (Eprex) injection and dialysis shift (being dialyzed in the morning) can have positive impact on dialysis adequacy. Patients should be educated on the facts that the type of device used for HD and the vascular access used has no significant effects on dialysis adequacy.
Hamiltonian fluid closures of the Vlasov-Ampère equations: From water-bags to N moment models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perin, M.; Chandre, C.; Tassi, E.
2015-09-15
Moment closures of the Vlasov-Ampère system, whereby higher moments are represented as functions of lower moments with the constraint that the resulting fluid system remains Hamiltonian, are investigated by using water-bag theory. The link between the water-bag formalism and fluid models that involve density, fluid velocity, pressure and higher moments is established by introducing suitable thermodynamic variables. The cases of one, two, and three water-bags are treated and their Hamiltonian structures are provided. In each case, we give the associated fluid closures and we discuss their Casimir invariants. We show how the method can be extended to an arbitrary numbermore » of fields, i.e., an arbitrary number of water-bags and associated moments. The thermodynamic interpretation of the resulting models is discussed. Finally, a general procedure to derive Hamiltonian N-field fluid models is proposed.« less
Space Station trash removal system
NASA Technical Reports Server (NTRS)
Petro, Andrew J. (Inventor)
1993-01-01
A trash removal system for space stations is described. The system is comprised of a disposable trash bag member and an attached, compacted large, lightweight inflatable balloon element. When the trash bag member is filled, the astronaut places the bag member into space through an airlock. Once in the vacuum of space, the balloon element inflates. Due to the large cross-sectional area of the balloon element relative to its mass, the combined balloon element and the trash bag member are slowed by atmospheric drag to a much greater extent than the Space Station's. The balloon element and bag member lose altitude and re-enter the atmosphere, and the elements and contents are destroyed by aerodynamic heating. The novelty of this system is in the unique method of using the vacuum of space and aerodynamic heating to dispose of waste material with a minimum of increase in orbital debris.
Air quality for metals and sulfur in Shanghai, China, determined with moss bags.
Cao, Tong; Wang, Min; An, Li; Yu, Yinghao; Lou, Yuxia; Guo, Shuiliang; Zuo, Benrong; Liu, Yan; Wu, Jiming; Cao, Yang; Zhu, Zhirui
2009-04-01
In order to better understand the spatial and temporal distribution pattern of metals and sulfur present in Shanghai, moss bags with Haplocladium microphyllum (Hedw.) Broth. were suspended at 14 local monitoring stations from April through June 2006 in Shanghai, the largest city in China. The results showed that the concentrations of S, Cu, Pb, and Zn in the moss bags after exposure were higher at the sites in the industrial district and most urban districts and lower at the sites in suburban areas, and well correlated with SO(2) API and PM10 API in the air both in terms of space and time. The present study provided evidence that the moss H. microphyllum is suitable for bio-monitoring air pollution with moss bags and further confirmed that the moss-bag method is a simple, inexpensive and useful technique.
Yanada, Shinobu; Sasaki, Masao; Takayama, Shinichi; Kaneda, Yasufumi; Miwa, Nobuhiko
2005-05-01
Hepatic injury subsequent to ischemia-reperfusion (I/R) was demonstrated in our previous study to be prevented by hemagglutinating virus of Japan (HVJ)-artificial viral envelope (AVE) liposome-mediated gene transfer of the antiapoptotic gene, human bcl-2 (h-bcl-2). In the present study, we introduced simultaneously both mouse Bcl-2-associated athanogene 1 (m-bag-1) and the h-bcl-2 gene by the same HVJ-AVE liposome transfection method, and found that I/R-induced hepatic injuries such as release of hepatic marker enzymes into blood, cell morphological degeneration, and cellular DNA strand cleavage were suppressed more effectively than by transfection with either gene singly. In addition, the h-Bcl-2 expression level in the ischemic state, but not in the nonischemic state, was markedly higher in h-bcl-2/m-bag-1-cotransfected liver than in h-bcl-2-transfected liver. In contrast, the m-BAG-1 expression level in the ischemic state, but not in the nonischemic state, was only slightly higher in h-bcl-2/m-bag-1-cotransfected liver than in m-bag-1-transfected liver. Thus, with dual gene cotransfer, coexistent Bcl-2 protein exerts no activity to assist a marked enhancement of BAG-1 protein, whereas the function of overexpressed BAG-1 as a Bcl-2-binding protein may lead to the enhancement of efficient expression of h-Bcl-2 in I/R-treated liver as compared with nonischemic liver, which results in repression of diverse I/R-induced cell death symptoms, presumably through the formation of functional complexes of BAG-1 and Bcl-2.
Capozzi, F; Giordano, S; Aboal, J R; Adamo, P; Bargagli, R; Boquete, T; Di Palma, A; Real, C; Reski, R; Spagnuolo, V; Steinbauer, K; Tretiach, M; Varela, Z; Zechmeister, H; Fernández, J A
2016-07-01
To develop an internationally standardized protocol for the moss bag technique application, the research team participating in the FP7 European project "MOSSclone" focused on the optimization of the moss bags exposure in terms of bag characteristics (shape of the bags, mesh size, weight/surface ratio), duration and height of exposure by comparing traditional moss bags to a new concept bag, "Mossphere". In particular, the effects of each variable on the metal uptake from the air were evaluated by a systematic experimental design carried out in urban, industrial, agricultural and background areas of three European countries with oceanic, Mediterranean and continental climate. The results evidenced that the shape, the mesh size of the bags and the exposure height (in the tested ranges), did not significantly influence the uptake capacity of the transplanted moss. The aspects more affecting the element uptake were represented by the density of the moss inside the bags and the relative ratio between its weight and the surface area of the bag. We found that, the lower the density, the higher the uptake recorded. Moreover, three weeks of exposure were not enough to have a consistent uptake signal in all the environments tested, thus we suggest an exposure period not shorter than 6 weeks, which is appropriate in most situations. The above results were confirmed in all the countries and scenarios tested. The adoption of a shared exposure protocol by the research community is strongly recommended since it is a key aspect to make biomonitoring surveys directly comparable, also in view of its recognition as a monitoring method by the EU legislation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Rasmussen, Mats; Damgaard, Rasmus; Buus, Peter; Mulhall, Brian; Guazzo, Dana Morton
2013-01-01
Part 1 of this three-part research series detailed the development and validation of a high-voltage leak detection test (HVLD, also known as an electrical conductivity and capacitance test) for verifying the container-closure integrity of a small-volume laminate plastic bag containing an aqueous solution formulation of the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. Leak detection capability was verified using positive controls each with a single laser-drilled hole in the bag film face. In this Part 2, HVLD leak detection capability was further explored in four separate studies. Study 1 investigated the ability of HVLD to detect weaknesses and/or gaps in the bag heat seal. Study 2 checked the HVLD detection of bag holes in packages stored 4 days at ambient conditions followed by 17 days at refrigeration. Study 3 examined HVLD test results for packages tested when cold. Study 4 compared HVLD test results as a function of bag plastic film lots. The final Part 3 of this series will report the impact of HVLD exposure on product visual appearance and chemical stability. In Part 1 of this three-part series, a leak test method based on electrical conductivity and capacitance, also called high-voltage leak detection (HVLD), was used to find leaks in small plastic bags filled with a solution for injection of the rapid-acting insulin analogue, insulin aspart (NovoRapid®/NovoLog®) by Novo Nordisk A/S, Bagsværd, Denmark. In this Part 2, HVLD leak detection capability was further explored in four separate studies. Study 1 investigated the ability of HVLD to detect bag heat seal leaks. Study 2 checked HVLD's ability to detect bag holes after a total of 21 days at ambient plus refrigerated temperatures. Study 3 looked to see if HVLD results changed for packages tested when still cold. Study 4 compared HVLD results for multiple bag plastic film lots. The final Part 3 of this series will report any evidence of drug component degradation caused by HVLD exposure.
Plantinga, Laura; Pastan, Stephen; Kramer, Michael; McClellan, Ann; Krisher, Jenna; Patzer, Rachel E.
2014-01-01
Background Improving access to optimal healthcare may depend on attributes of neighborhoods where patients receive healthcare services. We investigated whether characteristics of dialysis facility neighborhoods—where most patients with end-stage renal disease are treated—were associated with facility-level kidney transplantation. Methods We examined the association between census tract (neighborhood)-level sociodemographic factors and facility-level kidney transplantation rate in 3,983 U.S. dialysis facilities with reported kidney transplantation rates. Number of kidney transplants and total person-years contributed at the facility level in 2007-2010 were obtained from the Dialysis Facility Report and linked to census tract data on sociodemographic characteristics from the American Community Survey 2006-2010 by dialysis facility location. We used multivariable Poisson models with generalized estimating equations to estimate associations between neighborhood characteristics and transplant incidence. Results U.S. dialysis facilities were located in neighborhoods with substantially greater proportions of black and poor residents, relative to the national average. Most facility neighborhood characteristics were associated with transplant, with incidence rate ratios (95% CI) for standardized increments (in percentage) of neighborhood exposures of: living in poverty, 0.88 (0.84-0.92), black race, 0.83 (0.78-0.89); high school graduates, 1.22 (1.17-1.26); and unemployed, 0.90 (0.85-0.95). Conclusion Dialysis facility neighborhood characteristics may be modestly associated with facility rates of kidney transplantation. The success of dialysis facility interventions to improve access to kidney transplantation may partially depend on reducing neighborhood-level barriers. PMID:25196018
Wang, Tao; Tziviskou, Effie; Chu, Maggie; Bargman, Joanne; Jassal, Vanita; Vas, Stephen; Oreopoulos, Dimitrios G
2003-01-01
Recently it has been suggested that the survival of dialysis patients may differ among different races. Both registry data and data from Asian countries indicates that Asians on peritoneal dialysis may survive longer than their Caucasian counterparts. In the present study, we performed a detailed analysis of survival differences between oriental Asians and Caucasians on peritoneal dialysis in our multiethnic, multicultural program. Retrospectively we analyzed the survival data for patients who started peritoneal dialysis after January 1, 1996 and before December 31, 1999, in our hospital. They were followed for at least for two years. Excluded from the present analysis were those who survived for less than three months on peritoneal dialysis. The patient demographic characteristics, comorbidities, and residual renal function at the start of dialysis were collected. Indices for adequacy of dialysis were collected 1-3 months after the initiation of dialysis. Actuarial survival rates were determined by the Kaplan-Meier method. The Cox proportional hazards model was used to classify risk factors for a high mortality. There were 87 Caucasians and 29 Oriental Asian peritoneal dialysis patients. No differences were found in age, gender, primary renal disease, and residual renal function between the two groups. The Caucasians had significantly higher body surface area and urea volume and higher incidence of cardiovascular diseases. Even with slightly higher dialysis dose, the peritoneal creatinine clearance was significantly lower among the Caucasians than among Asians. There was no difference in the peritoneal D/P value between the two groups. However, compared to the Caucasians, the 24hr peritoneal fluid removal and total fluid removal volumes were significantly lower in the Asian patients. The one, two, three and four year survival rates were 95.8%, 91%, 86% and 80% for Asians and 91.3%, 78.1%, 64.7% and 54.1% for Caucasians. Significant predictors for a higher mortality were the presence of cardiovascular disease (42% increase in risk), Caucasians (39% increase in risk) and older age (37% increase in risk for age older than 65). Our study confirms that oriental Asians on peritoneal dialysis patients survive much longer than their Caucasian counterparts; this was partly due to the fact that Asian patients have less cardiovascular disease when they began peritoneal dialysis. Due to their smaller body size, the Asians tended to have a higher peritoneal small solute clearances despite their smaller dialysis doses, indicating that, to achieve the same solute clearance targets, Asians need a smaller dialysis dose compared to Caucasians.
Hyun, Hong-Keun; Ferracane, Jack L.
2016-01-01
Objective Bioactive glass (BAG) has been suggested as a possible additive for dental restorative materials because of its antimicrobial effect and potential for promoting apatite formation in body fluids. The purpose of this study was to investigate the effects of bacterial biofilm on the change of colorimetric value and translucency of novel BAG-containing composites having different initial surface roughness. Methods Composites with 72 wt% total filler load were prepared by replacing 15% of the silanized Sr glass with BAG (65 mole% Si; 4% P; 31% Ca), BAG-F (61% Si; 31% Ca; 4% P; 3% F; 1% B), or silanized silica. Light-cured discs of 2-mm thickness (n=10/group) were divided into 4 different surface roughness subgroups produced by wet polishing with 600 and then up to 1200, 2400, or 4000 grit SiC. CIE L*a*b* were measured and the color difference and translucency parameter (TP) were calculated before and after incubating in media with or without a S. mutans (UA 159) biofilm for 2 wks (no agitation). Results were analyzed using ANOVA/Tukey's test (α = 0.05). Results All the color differences for BAG and BAG-F composite showed significant decreases with bacterial biofilm compared to media-only. The mean TP (SD) of BAG and BAG-F composite before aging [10.0 (2.8) and 8.5 (1.4)] was higher than that of the control composite [4.9 (0.8)], while the change in TP with aging was greater compared to the control with or without bacteria. BAG-F composites with the smoothest surfaces showed a greater decrease in TP under bacterial biofilm compared to the BAG composite. Significance Highly polished dental composites containing bioactive glass additives may become slightly rougher and show reduced translucency when exposed to bacterial biofilms, but do not discolor any more than control composites that do not contain the BAG. PMID:27394086
Kumar, Aswin; Majgi, Sumanth Mallikarjuna; Kumar, Ganesh S; Prahalad, Raghavendra Babu Yellapur
2016-01-01
Introduction Plastic bag users are at risk of number of health hazards. There is paucity of data with regard to awareness of health hazards among general population in India. Aim This study was done to find out the status of awareness of the health hazards associated with the usage of plastic bags among people and their perception towards the legislation prohibiting the usage of plastic bags. Materials and Methods This cross-sectional study conducted in Mangalore city in August 2013. Data was collected by interviewing any adult member (aged above 18 years) in each of the selected households using an interview schedule. Results Mean age of the 250 participants was 32.8±10.8 years. Majority 160(64%) were females educated up to undergraduate level or above 187(74.8%). Among the participants 216(86.4%) were aware of the health hazards associated with the use of plastic bags. Awareness was significantly more amongst females (p=0.027), well-educated participants (p=0.004) and among professionals and semi-professionals (p<0.001). There were 50(20%) participants reusing plastic bags for shopping after initial usage. The cloth bags were used for shopping in place of plastic bags by 13(5.2%) participants. Among the participants 213(85.2%) were aware of the legislation banning the use of plastic bags and out of which 166(77.9%) were in its favour. Semi-professionals and students favoured the ban on plastic bags whereas unskilled and semiskilled workers were against the ban (p=0.01). Conclusion Most of the participants in the settings had the awareness of hazards of plastic bag usage. However, there is a need for spreading the awareness of using alternative strategies and effective implementation of legislation in order to minimize the usage of plastics in the community. PMID:27190841
NASA Astrophysics Data System (ADS)
Dang, Thi Cam Ha; Thang Nguyen, Dang; Thai, Hoang; Chinh Nguyen, Thuy; Thu Hien Tran, Thi; Le, Viet Hung; Huynh Nguyen, Van; Bach Tran, Xuan; Phuong Thao Pham, Thi; Giang Nguyen, Truong; Nguyen, Quang Trung
2018-03-01
Three different kinds of plastic bags HL, VHL, and VN1 with different chemical nature were degraded by a novel thermophilic bacterial strain isolated from composting agricultural residual in Vietnam in shaking liquid medium at 55 °C after 30 d. The new strain was classified in the Bacillus genus by morphological property and sequence of partial 16Sr RNA coding gene and named as Bacillus sp. BCBT21. This strain could produce extracellular hydrolase enzymes including lipase, CMCase, xylanase, chitinase, and protease with different level of activity in the same media. After a 30-d treatment at 55 °C with Bacillus sp. BCBT21, all characteristics including properties and morphology of treated plastic bags had been significantly changed. The weight loss, structure and surface morphology of these bags as well as the change in the average molecular weight of VHL bag were detected. Especially, the average molecular weight of VHL bag was significantly reduced from 205 000 to 116 760. New metabolites from the treated bags indicated biodegradation occurring with the different pathways. This finding suggests that there is high potential to develop an effective integrated method for plastic bags degradation by a combination of extracellular enzymes from bacteria and fungi existing in the composting process.
The Effect of BCAA and ISO-WHEY Oral Nutritional Supplements on Dialysis Adequacy.
Afaghi, Effat; Tayebi, Ali; Ebadi, Abbas; Sobhani, Vahid; Einollahi, Behzad; Tayebi, Mehdi
2016-11-01
Protein-energy malnutrition is a common problem in hemodialysis patients and has different outcomes such as reduced quality of life, longer hospitalization time, lower dialysis adequacy, and higher mortality rate. Investigation of dialysis adequacy is an important method for assessing hemodialysis patients, and improving the dialysis adequacy is an important healthcare team goal. The present study aims to investigate and compare the effects of BCAA and ISO-WHEY oral nutritional supplements on dialysis adequacy. In a clinical trial study, 66 hemodialysis patients were randomly divided into three groups: Group A (n = 22), Group B (n = 22), and Group C or the control group (n = 22). In Groups A and B, as prescribed and controlled by nutritionists and nephrologists, respectively, ISO-WHEY and BCAA protein powder were used for 2 months on a daily basis. For all groups, before intervention and 1 and 2 months after intervention, the dialysis adequacy was measured using URR and Kt/V. Finally, the data were analyzed using IBM SPSS Statistics Base 21.0 software. Out of 66 patients, 61 (19 in Group A, 20 in Group B, and 22 in Group C) completed the study period, and before intervention, all groups were equal in terms of quality and quantity variables (P > 0.05). After intervention, there was a significant difference between the three groups with regard to the variables of dialysis adequacy based on Kt/V and URR to independent-t test and repeated measures ANOVA (P < 0.05). Results show that the intake of oral nutritional supplements leads to an improvement in the dialysis adequacy of hemodialysis patients. Therefore, the use of nutritional supplements along with patients' training and regular consultation will be helpful in improving the nutritional status, dialysis adequacy, and eventually the quality of life.
Feasibility and Safety of Intra-Dialysis Yoga and Education in Maintenance Hemodialysis Patients
Birdee, Gurjeet S.; Rothman, Russell L.; Sohl, Stephanie J.; Wertenbaker, Dolphi; Wheeler, Amy; Bossart, Chase; Balasire, Oluwaseyi; Ikizler, T. Alp
2016-01-01
Objective Patients with end-stage renal disease on maintenance hemodialysis are much more sedentary than healthy individuals. The purpose of this study was to assess the feasibility and safety of a 12-week intra-dialysis yoga intervention versus a kidney education intervention on the promotion of physical activity. Design and Methods We randomized participants by dialysis shift to either 12-week intra-dialysis yoga or an educational intervention. Intra-dialysis yoga was provided by yoga teachers to participants while receiving hemodialysis. Participants receiving the 12-week educational intervention received a modification of a previously developed comprehensive educational program for patients with kidney disease (“Kidney School”). The primary outcome for this study was feasibility based on recruitment and adherence to the interventions, and safety of intra-dialysis yoga. Secondary outcomes were to determine the feasibility of administering questionnaires at baseline and 12-weeks including the Kidney Disease-Related Quality of Life-36. Results Among 56 eligible patients approached for the study, 55% (n=31) were interested and consented to participation with 18 assigned to intra-dialysis yoga and 13 to the educational program. A total of 5 participants withdrew from the pilot study, all from the intra-dialysis yoga group. Two of these participants reported no further interest in participation. Three withdrawn participants switched dialysis times and therefore could no longer receive intra-dialysis yoga. As a result, 72% (13 of 18) and 100% (13 of 13) of participants completed 12-week intra-dialysis yoga and educational programs, respectively. There were no adverse events related to intra-dialysis yoga. Intervention participants practiced yoga a median of 21 sessions (70% participation frequency), with 60% of participants practicing at least 2 times a week. Participants in the educational program completed a median of 30 sessions (83% participation frequency). Of participants who completed the study (n=26), baseline and 12-week questionnaires were obtained from 85%. Conclusions Our pilot study of a 12-week intra-dialysis yoga and 12-week educational intervention reached recruitment goals, but less than targeted completion and adherence to intervention rates. This study provided valuable feasibility data to increase follow-up and adherence for future clinical trials to compare efficacy. PMID:25869658
2012-01-01
Background Long term longitudinal data are scarce on epidemiological characteristics and patient outcomes in patients on maintenance dialysis, especially in Switzerland. We examined changes in epidemiology of patients undergoing renal replacement therapy by either hemodialysis or peritoneal dialysis over four decades. Methods Single center retrospective study including all patients which initiated dialysis treatment for ESRD between 1970 and 2008. Analyses were performed for subgroups according to dialysis vintage, based on stratification into quartiles of date of first treatment. A multivariate model predicting death and survival time, using time-dependent Cox regression, was developed. Results 964 patients were investigated. Incident mean age progressively increased from 48 ± 14 to 64 ± 15 years from 1st to 4th quartile (p < 0.001), with a concomitant decrease in 3- and 5-year survival from 72.2 to 67.7%, and 64.1 to 54.8%, respectively. Nevertheless, live span continuously increased from 57 ± 13 to 74 ± 11 years (p < 0.001). Patients transplanted at least once were significantly younger at dialysis initiation, with significantly better survival, however, shortened live span vs. individuals remaining on dialysis. Among age at time of initiating dialysis therapy, sex, dialysis modality and transplant status, only transplant status is a significant independent covariate predicting death (HR: 0.10 for transplanted vs. non-transplanted patients, p = 0.001). Dialysis vintage was associated with better survival during the second vs. the first quartile (p = 0.026). Discussion We document an increase of a predominantly elderly incident and prevalent dialysis population, with progressively shortened survival after initiation of renal replacement over four decades, and, nevertheless, a prolonged lifespan. Analysis of the data is limited by lack of information on comorbidity in the study population. Conclusions Survival in patients on renal replacement therapy seems to be affected not only by medical and technical advances in dialysis therapy, but may mostly reflect progressively lower mortality of individuals with cardiovascular and metabolic complications, as well as a policy of accepting older and polymorbid patients for dialysis in more recent times. This is relevant to make demographic predictions in face of the ESRD epidemic nephrologists and policy makers are facing in industrialized countries. PMID:22747751
Paolino, Kristopher M.; Osborn, Erik C.; Rusnak, Janice M.; Günther, Stephan; Pool, Jane; Rollin, Pierre E.; Allan, Patrick F.; Schmidt-Chanasit, Jonas; Rieger, Toni; Kortepeter, Mark G.
2015-01-01
In 2009, a lethal case of Crimean–Congo hemorrhagic fever (CCHF), acquired by a US soldier in Afghanistan, was treated at a medical center in Germany and resulted in nosocomial transmission to 2 health care providers (HCPs). After his arrival at the medical center (day 6 of illness) by aeromedical evacuation, the patient required repetitive bronchoscopies to control severe pulmonary hemorrhage and renal and hepatic dialysis for hepatorenal failure. After showing clinical improvement, the patient died suddenly on day 11 of illness from cerebellar tonsil herniation caused by cerebral/cerebellar edema. The 2 infected HCPs were among 16 HCPs who received ribavirin postexposure prophylaxis. The infected HCPs had mild or no CCHF symptoms. Transmission may have occurred during bag-valve-mask ventilation, breaches in personal protective equipment during resuscitations, or bronchoscopies generating infectious aerosols. This case highlights the critical care and infection control challenges presented by severe CCHF cases, including the need for experience with ribavirin treatment and postexposure prophylaxis. PMID:25529825
The effects of serum leptin levels on thrombocyte aggregation in peritoneal dialysis patients
Bakirdogen, Serkan; Eren, Necmi; Bek, Sibel Gokcay; Mehtap, Ozgur; Cekmen, Mustafa Baki
2016-01-01
Objective: Serum leptin levels of chronic kidney disease patients have been detected higher than normal population. The aim of this study was to investigate the effects of serum leptin levels on thrombocyte aggregation in peritoneal dialysis patients. Methods: Fourty three peritoneal dialysis patients were included in the study. Thrombocyte aggregation was calculated from the whole blood subsequently the effects of different concentrations of human recombinant leptin on thrombocyte aggregations were investigated. Four test cells were used for this process. While leptin was not added into the first test cell, increasing amounts of leptin was added into the second, third and fourth test cells to attain the concentrations of 25, 50 and 100 ng/ml respectively. Results: Thrombocyte aggregation was inhibited by recombinant leptin in peritoneal dialysis patients. Thrombocyte aggregation mean values were found statistically significantly higher in first test cell when compared to leptin groups in peritoneal dialysis patients. For leptin groups we could not find any statistically significant differences for thrombocyte aggregation mean values between any of the groups. Conclusion: Further studies with larger number of peritoneal dialysis patients are required to prove the action of leptin on thrombocyte aggregation. PMID:28083046
The Experience of Older People in the Shared Decision-Making Process in Advanced Kidney Care.
Thomas, Nicola; Jenkins, Karen; McManus, Breeda; Gracey, Brian
2016-01-01
Introduction . This qualitative descriptive study was designed to understand the experiences of older people (>70 years) when making a decision about renal replacement therapy. This was a coproduced study, whereby patients and carers were involved in all aspects of the research process. Methods . A Patient and Carer Group undertook volunteer and research training. The group developed the interview questions and interviewed 29 people who had commenced dialysis or made a decision not to have dialysis. Interview data were transcribed and analysed, and common themes were identified. Results . 22 men and 7 women (mean age 77.4 yrs) from two hospitals were interviewed. 18 had chosen haemodialysis, 6 peritoneal dialysis, and 5 supportive care. The majority of patients were involved in the dialysis decision. Most were satisfied with the amount of information that they received, although some identified that the quality of the information could be improved, especially how daily living can be affected by dialysis. Conclusion . Our findings show that overall older patients were involved in the dialysis decision along with their families. Our approach is innovative because it is the first time that patients and carers have been involved in a coproduced study about shared decision-making.
Lower risk of end stage renal disease in diabetic nurse
Pan, Cheng-Chin; Huang, Hsiu-Ling; Chen, Ming-Chih; Kung, Chuan-Yu; Kung, Pei-Tseng; Chou, Wen-Yu; Tsai, Wen-Chen
2017-01-01
Objectives: As professional medical caregivers, nurses have extensive medical knowledge and information than general population. However, they may use their professional knowledge and networks to seek prompt health services. In this study, we aimed to determine susceptibility of nurses with diabetes to developing end-stage renal disease requiring dialysis compared to diabetes patients in the general population. Methods: This retrospective longitudinal study extracted data of nurses with newly diagnosed diabetes and general patients with diabetes from the National Health Insurance Database between 1998 and 2006 and follow-up to December 2009, satisfied the participant inclusion criteria was 518,058. Nurses and general population were matched with propensity score method in a 1:10 ratio. Basic characteristics and health status were similar between groups. Cox proportional hazards model was used to compare relative risks and dialysis factors between groups. Results: Nurses were younger than general population with diabetes (42.01 years vs. 59.29 years) and had lower risk of dialysis (adjusted hazard ratio = 0.36, 95% confidence interval 0.16-0.81). Nurses with Diabetes Complications Severity Index (DCSI)≧3 had dialysis risk up to 83.53 times higher than that of the reference group (DCSI < 3). DCSI was the only variable determined to be a related factor affecting dialysis risk in nurses with diabetes. Conclusions: Nurses with diabetes have lower risk of dialysis. This suggests that nurses may have more knowledge regarding chronic disease control and change their lifestyles than general diabetes patients. Results of this study may serve as a reference for developing health education. PMID:29130450
Baillie, Jessica; Gill, Paul; Courtenay, Molly
2018-01-01
This article is a report of a study protocol designed to examine patients' and families' knowledge and experiences of peritoneal dialysis-associated peritonitis. Peritonitis is a considerable problem for people using peritoneal dialysis, leading to antibiotics, hospitalization and decreased quality of life. For some patients, peritonitis requires changing renal replacement therapy and can be fatal. Peritonitis is distressing and some patients are unfamiliar with the signs and symptoms. Patients with better knowledge of peritonitis and adherence to peritoneal dialysis procedures have lower rates of peritonitis. Little is known about patients' and families' knowledge and experience of peritoneal dialysis-associated peritonitis in the United Kingdom. Ethical approval was gained in March 2017. To meet the study aim, a two-phase sequential explanatory mixed methods study is proposed. Phase One: An author-developed questionnaire will be sent to patients using peritoneal dialysis at five sites in England and Wales. Patients will be asked to consider inviting a relative to participate. The questionnaire will assess peritonitis knowledge and experience. Data will be analysed statistically. Phase Two: Semi-structured interviews will be conducted with a purposive sample of Phase One participants (n = 30) to explore their experiences of peritonitis in further depth. The data will be analysed thematically using Wolcott's (1994) approach. Data from the two phases will be synthesized to identify patients' and families' peritonitis information needs, to ensure they are appropriately supported to prevent, monitor, identify and report peritonitis. © 2017 John Wiley & Sons Ltd.
James, Ray
2009-12-01
Chlorine-based products are widely used in the water supply industry, and the potential for adverse effects in the haemodialysis setting is well documented. To date, the most commonly used method of chlorine removal has been granular activated carbon filters. An increasingly popular method of dechlorination is the use of high intensity, broad-spectrum UV systems to reduce both free chlorine and combined chlorine compounds (chloramines) into easily removed by-products. UV radiation has been successfully used in the pharmaceutical and food industries to destroy free chlorine and/or chloramines present in water, and kill all known spoilage microorganisms including bacteria, viruses, yeasts and moulds (and their spores). This nonchemical method can offer significant advantages and benefits compared to conventional dechlorination technologies currently employed in dialysis water systems. Whilst UV treatment at 254 nm wavelength has been routinely used for disinfection purposes in dialysis water systems, this paper considers whether UV radiation can be used as an alternative to more traditional methods of chlorine removal.
Bagging system, soil stabilization mat, and tent frame for a lunar base
NASA Technical Reports Server (NTRS)
1990-01-01
Georgia Tech's School of Textile and Fiber Engineering and School of Mechanical Engineering participated in four cooperative design efforts this year. Each of two interdisciplinary teams designed a system consisting of a lunar regolith bag and an apparatus for filling this bag. The third group designed a mat for stabilization of lunar soil during takeoff and landing, and a method for packaging and deploying this mat. Finally, the fourth group designed a sunlight diffusing tent to be used as a lunar worksite. Summaries of these projects are given.
Bagging system, soil stabilization mat, and tent frame for a lunar base
NASA Astrophysics Data System (ADS)
1990-11-01
Georgia Tech's School of Textile and Fiber Engineering and School of Mechanical Engineering participated in four cooperative design efforts this year. Each of two interdisciplinary teams designed a system consisting of a lunar regolith bag and an apparatus for filling this bag. The third group designed a mat for stabilization of lunar soil during takeoff and landing, and a method for packaging and deploying this mat. Finally, the fourth group designed a sunlight diffusing tent to be used as a lunar worksite. Summaries of these projects are given.
Recovery of agricultural odors and odorous compounds from polyvinyl fluoride film bags
USDA-ARS?s Scientific Manuscript database
Accurate sampling methods are necessary when quantifying odor and volatile organic compound emissions at agricultural facilities. The commonly accepted methodology in the U.S. has been to collect odor samples in polyvinyl fluoride bags (PVF, brand name Tedlar®) and, subsequently, analyze with human ...
A gas chromatographic system was used to quantitate more than 300 gas-phase hydrocarbons from background and roadside ambient air samples. Samples were simultaneously collected in Tedlar bags and on Tenax cartridges. Hydrocarbons from Tedlar bag-collected samples were quantitated...
Peritoneum: a noble membrane in long-term dialysis treatment.
Barone, Roberto J; Campora, María I; Gimenez, Nélida S; Ramirez, Liliana; Santopietro, Mónica; Grbavac, Drago; Pattin, Mauricio; Panese, Sergio A
2009-01-01
The durability of the peritoneum as a dialysis membrane is as yet an unanswered question. Peritonitis episodes have an important effect in long-term treatment. To evaluate survival of the peritoneum for dialysis, we analyzed peritoneal failure related to technique dropout because of peritonitis, inadequate dialysis, and ultrafiltration disorders. We retrospectively analyzed data for 89 peritoneal dialysis patients who had been treated for at least 3 months [52 women, 37 men; mean age: 50.91 +/- 13.72 years (range: 22 - 81 years)] from August 4, 1993, to July 1, 2008. The Kaplan-Meier method was used to measure peritoneum survival, with only a definitive switch to hemodialysis or death from peritonitis, ultrafiltration failure, or inadequate dialysis as endpoints. Total treatment time was 5008 patient-months (mean: 55 +/- 44 patient-months), and the historical annual rate of peritonitis was 0.37 per year at risk (1 episode in 32.52 patient-months). Of the 89 patients, 19 dropped treatment because of peritonitis and 1 because of ultrafiltration failure. Peritoneum survival was 98.8%, 93.7%, 87.6%, 66.9%, 46.4%, and 33.8% at 1, 3, 5, 8, 10, and 14 years. In the 15 years of our program, peritoneum failure represented less than 1.5% of drop-out causes annually. The peritoneum is a reliable membrane to reach dialysis targets in long-term therapy.
Quinn, Robert R.; Ravani, Pietro; Zhang, Xin; Garg, Amit X.; Blake, Peter G.; Austin, Peter C.; Zacharias, James M.; Johnson, John F.; Pandeya, Sanjay; Verrelli, Mauro; Oliver, Matthew J.
2014-01-01
♦ Background: Hospitalization rates are a relevant consideration when choosing or recommending a dialysis modality. Previous comparisons of peritoneal dialysis (PD) and hemodialysis (HD) have not been restricted to individuals who were eligible for both therapies. ♦ Methods: We conducted a multicenter prospective cohort study of people 18 years of age and older who were eligible for both PD and HD, and who started outpatient dialysis between 2007 and 2010 in four Canadian dialysis programs. Zero-inflated negative binomial models, adjusted for baseline patient characteristics, were used to examine the association between modality choice and rates of hospitalization. ♦ Results: The study enrolled 314 patients. A trend in the HD group toward higher rates of hospitalization, observed in the primary analysis, became significant when modality was treated as a time-varying exposure or when the population was restricted to elective outpatient starts in patients with at least 4 months of pre-dialysis care. Cardiovascular disease, infectious complications, and elective surgery were the most common reasons for hospital admission; only 23% of hospital stays were directly related to complications of dialysis or kidney disease. ♦ Conclusions: Efforts to promote PD utilization are unlikely to result in increased rates of hospitalization, and efforts to reduce hospital admissions should focus on potentially avoidable causes of cardiovascular disease and infectious complications. PMID:24525596
Liu, Jiannong; Li, Suying; Gilbertson, David T; Monda, Keri L; Bradbury, Brian D; Collins, Allan J
2014-10-01
Because transfusion avoidance has been the cornerstone of anemia treatment for patients with kidney disease, direct measurement of red blood cell transfusion use to assess dialysis facility anemia management performance is reasonable. We aimed to explore methods for estimating facility-level standardized transfusion ratios (STfRs) to assess provider anemia treatment practices. Retrospective cohort study. Point prevalent US hemodialysis patients on January 1, 2009, with Medicare as primary payer and dialysis duration of 90 days or longer were included (n = 223,901). All dialysis facilities with eligible patients were included (n = 5,345). Dialysis facility assignment. Receiving a red blood cell transfusion in the inpatient or outpatient setting. We evaluated 3 approaches for estimating STfR: ratio of observed to expected numbers of transfusions (STfR(obs)), a Bayesian approach (STfR(Bayes)), and a modified version of the Bayesian approach (STfR(modBayes)). The overall national transfusion rate in 2009 was 23.2 per 100 patient-years. Our model for predicting the expected number of transfusions performed well. For large facilities, all 3 STfRs worked well. However, for small facilities, while the STfR(modBayes) worked well, STfR(obs) values demonstrated instability and the STfR(Bayes) may produce more bias. Administration of transfusions to dialysis patients reflects medical practice both within and outside the dialysis unit. Some transfusions may be deemed unavoidable and transfusion practices are subject to considerable regional variation. Development of an STfR metric is feasible and reasonable for assessing anemia treatment at dialysis facilities. The STfR(obs) is simple to calculate and works well for larger dialysis facilities. The STfR(modBayes) is more analytically complex, but facilitates comparisons across all dialysis facilities, including small facilities. Copyright © 2014 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Puyuelo, Belén; Colón, Joan; Martín, Patrícia; Sánchez, Antoni
2013-06-01
The separation of biowaste at home is key to improving, facilitating and reducing the operational costs of the treatment of organic municipal waste. The conventional method of collecting such waste and separating it at home is usually done by using a sealed bin with a plastic bag. The use of modern compostable bags is starting to be implemented in some European countries. These compostable bags are made of biodegradable polymers, often from renewable sources. In addition to compostable bags, a new model of bin is also promoted that has a perforated surface that, together with the compostable bag, makes the so-called "aerated system". In this study, different combinations of home collection systems have been systematically studied in the laboratory and at home. The results obtained quantitatively demonstrate that the aerated bin and compostable bag system combination is effective at improving the collection of biowaste without significant gaseous emissions and preparing the organic waste for further composting as concluded from the respiration indices. In terms of weight loss, temperature, gas emissions, respiration index and organic matter reduction, the best results were achieved with the aerated system. At the same time, a qualitative study of bin and bag combinations was carried in 100 homes in which more than 80% of the families participating preferred the aerated system. Copyright © 2013 Elsevier Ltd. All rights reserved.
Nekkanti, Vijaykumar; Venkatesan, Natarajan; Wang, Zhijun; Betageri, Guru V
2015-01-01
The objective of our investigational work was to develop a proliposomal formulation to improve the oral bioavailability of valsartan. Proliposomes were formulated by thin film hydration technique using different ratios of phospholipids:drug:cholesterol. The prepared proliposomes were evaluated for vesicle size, encapsulation efficiency, morphological properties, in vitro drug release, in vitro permeability and in vivo pharmacokinetics. In vitro drug-release studies were performed in simulated gastric fluid (pH 1.2) and purified water using dialysis bag method. In vitro drug permeation was studied using parallel artificial membrane permeation assay (PAMPA), Caco-2 monolayer and everted rat intestinal perfusion techniques. In vivo pharmacokinetic studies were conducted in male Sprague Dawley (SD) rats. Among the proliposomal formulations, F-V was found to have the highest encapsulation efficiency of 95.6 ± 2.9% with a vesicle size of 364.1 ± 14.9 nm. The in vitro dissolution studies indicated an improved drug release from proliposomal formulation, F-V in comparison to pure drug suspension in both, purified water and pH 1.2 dissolution media after 12 h. Permeability across PAMPA, Caco-2 cell and everted rat intestinal perfusion studies were higher with F-V formulation as compared to pure drug. Following single oral administration of F-V formulation, a relative bioavailability of 202.36% was achieved as compared to pure valsartan.
Comparison of techniques for culture of dialysis water and fluid.
Maltais, Jo-Ann B; Meyer, Klemens B; Foster, Meredith C
2017-04-01
Microbiological culture of dialysis water and fluid is a routine safety measure. In the United States (U.S.), laboratories perform these cultures on trypticase soy agar at 35-37°C for 48 h (TSA-48h), not on the tryptone glucose extract agar or Reasoner's 2A agar at 17-23°C for 7 days (TGEA-7d and R2A-7d, respectively) recommended by international standards. We compared culture methods to identify samples exceeding the accepted action level of 50 CFU/mL. Dialysis water and fluid samples collected from 41 U.S. dialysis programs between 2011 and 2014 were cultured at two U.S. laboratories. Each sample was cultured using (1) either TGEA-7d or R2A-7d and (2) TSA-48h. We compared proportions exceeding the action level by different methods and test characteristics of TSA-48h to those of TGEA-7d and R2A-7d. The proportion of water samples yielding colony counts ≥50 CFU/mL by TGEA-7d was significantly different from the proportion by TSA-48h (P = 0.001; difference in proportion 4.3% [95%CI 1.3-7.3%]). The proportions of dialysis fluid samples ≥50 CFU/mL by TGEA-7d and TSA-48h were not significantly different; there were no significant differences for comparisons of R2A-7d to TSA-48h. In dialysis fluid, TSA-48h was comparable to TGEA-7d and R2A-7d in identifying samples as having bacterial counts ≥50 CFU/mL. In dialysis water, TSA-48h was comparable to R2A-7d in identifying samples ≥50 CFU/mL, but TGEA-7d did yield significantly more results above 50 CFU/mL. Nonetheless, the negative predictive value of a TSA-48h result of <50 CFU/mL in dialysis water exceeded 95%. © 2016 The Authors Hemodialysis International published by Wiley Periodicals, Inc. on behalf of International Society for Hemodialysis.
Video Analytics Evaluation: Survey of Datasets, Performance Metrics and Approaches
2014-09-01
training phase and a fusion of the detector outputs. 6.3.1 Training Techniques 1. Bagging: The basic idea of Bagging is to train multiple classifiers...can reduce more noise interesting points. Person detection and background subtraction methods were used to create hot regions. The hot regions were...detection algorithms are incorporated with MHT to construct one integrated detector /tracker. 6.8 IRDS-CASIA team IRDS-CASIA proposed a method to solve a
Maruyama, Yukio; Yokoyama, Keitaro; Yokoo, Takashi; Shigematsu, Takashi; Iseki, Kunitoshi; Tsubakihara, Yoshiharu
2015-01-01
Background/Aims Monitoring of serum ferritin levels is widely recommended in the management of anemia among patients on dialysis. However, associations between serum ferritin and mortality are unclear and there have been no investigations among patients undergoing peritoneal dialysis (PD). Methods Baseline data of 191,902 patients on dialysis (age, 65 ± 13 years; male, 61.1%; median dialysis duration, 62 months) were extracted from a nationwide dialysis registry in Japan at the end of 2007. Outcomes, such as one-year mortality, were then evaluated using the registry at the end of 2008. Results Within one year, a total of 15,284 (8.0%) patients had died, including 6,210 (3.2%) cardiovascular and 2,707 (1.4%) infection-related causes. Higher baseline serum ferritin levels were associated with higher mortality rates among patients undergoing hemodialysis (HD). In contrast, there were no clear associations between serum ferritin levels and mortality among PD patients. Multivariate Cox regression analysis of HD patients showed that those in the highest serum ferritin decile group had higher rates of all-cause and cardiovascular mortality than those in the lowest decile group (hazard ratio [HR], 1.54; 95% confidence interval [CI], 1.31–1.81 and HR, 1.44; 95% CI, 1.13–1.84, respectively), whereas associations with infection-related mortality became non-significant (HR, 1.14; 95% CI, 0.79–1.65). Conclusions Using Japanese nationwide dialysis registry, higher serum ferritin values were associated with mortality not in PD patients but in HD patients. PMID:26599216
Hydration Status of Patients Dialyzed with Biocompatible Peritoneal Dialysis Fluids
Lichodziejewska-Niemierko, Monika; Chmielewski, Michał; Dudziak, Maria; Ryta, Alicja; Rutkowski, Bolesław
2016-01-01
♦ Background: Biocompatible fluids for peritoneal dialysis (PD) have been introduced to improve dialysis and patient outcome in end-stage renal disease. However, their impact on hydration status (HS), residual renal function (RRF), and dialysis adequacy has been a matter of debate. The aim of the study was to evaluate the influence of a biocompatible dialysis fluid on the HS of prevalent PD patients. ♦ Methods: The study population consisted of 18 prevalent PD subjects, treated with standard dialysis fluids. At baseline, 9 patients were switched to a biocompatible solution, low in glucose degradation products (GDPs) (Balance; Fresenius Medical Care, Bad Homburg, Germany). Hydration status was assessed through clinical evaluation, laboratory parameters, echocardiography, and bioimpedance spectroscopy over a 24-month observation period. ♦ Results: During the study period, urine volume decreased similarly in both groups. At the end of the evaluation, there were also no differences in clinical (body weight, edema, blood pressure), laboratory (N-terminal pro-brain natriuretic peptide, NTproBNP), or echocardiography determinants of HS. However, dialysis ultrafiltration decreased in the low-GDP group and, at the end of the study, equaled 929 ± 404 mL, compared with 1,317 ± 363 mL in the standard-fluid subjects (p = 0.06). Hydration status assessed by bioimpedance spectroscopy was +3.64 ± 2.08 L in the low-GDP patients and +1.47 ± 1.61 L in the controls (p = 0.03). ♦ Conclusions: The use of a low-GDP biocompatible dialysis fluid was associated with a tendency to overhydration, probably due to diminished ultrafiltration in prevalent PD patients. PMID:26475845
Sundaram, S; Cendoroglo, M; Cooker, L A; Jaber, B L; Faict, D; Holmes, C J; Pereira, B J
1997-11-01
Low pH, high osmolality, increasing glucose concentration, and glucose degradation products (GDP) formed during heat sterilization of conventional peritoneal dialysis (PD) fluids have been shown to have a detrimental effect on cells involved in peritoneal host defense. The two-chambered PD fluid bag in which glucose at pH approximately 3 is separated from a bicarbonate (25 mmol/L)-lactate (15 mmol/L) buffer during heat sterilization permits PD fluids with lower GDP to be delivered to the patient at neutral pH. To establish the possible benefit of two-chambered bag PD fluids on peripheral blood mononuclear cell (PBMC) and polymorphonuclear (PMN) cell function, we compared conventional 1.5% Dianeal (1.5%D) with 1.5% two-chambered bag bicarbonate-lactate (1.5%D-B), and conventional 4.25% Dianeal (4.25%D) with 4.25% two-chambered bag bicarbonate-lactate (4.25%D-B). Furthermore, to study the effect of the sterilization process on PBMC and PMN function, we compared filter-sterilized 4.25%D (4.25%D-F) with 4.25%D and 4.25%D-B. PBMC were harvested by Ficoll-Hypaque separation, and 2.5 x 10(6) cells in RPMI were incubated with an equal volume of the test fluids for 4 hours, pelleted, and resuspended in RPMI containing 10 ng endotoxin for a further 20 hours. Tumor necrosis factor alpha (TNF-alpha) production by endotoxin-stimulated PBMC was not significantly different (P = 0.10) between 1.5%D-B and 1.5%D, but was significantly higher (P = 0.01) with 4.25%D-B compared with 4.25%D. PBMC exposed to filter-sterilized fluid (4.25%D-F) showed significantly higher endotoxin-stimulated TNF-alpha production compared with 4.25%D (P = 0.02), but was not significantly different from 4.25%D-B (P = 0.40). PMN were harvested by Ficoll-Hypaque separation and 10 x 10(6) cells incubated with test fluids for 30 minutes. After incubation, phagocytosis (phagocytosis index) was determined by the uptake of 14C-labeled Staphylococcus aureus, oxidative burst by reduction of ferricytochrome C to ferrocytochrome C on stimulation with PMA, and enzyme release by measurement of endotoxin-stimulated bactericidal/permeability increasing protein (BPI). Bicarbonate-lactate two-chambered fluids of similar osmolality and glucose concentration conferred a significant improvement in phagocytosis (P = 0.02 for 1.5%D-B and P < 0.001 for 4.25%D-B). Oxidative burst and BPI release were significantly higher in 4.25%D-B compared with 4.25%D (P < 0.001). Filter-sterilized 4.25%D-F conferred a significant improvement in phagocytosis and oxidative burst compared with 4.25%D (P < 0.001) or 4.25%D-B (P < 0.001). Furthermore, conventional 4.25%D was associated with significantly lower BPI release compared with 4.25%D-F (P = 0.01). GDP's acetaldehyde and 5-HMF were analyzed in 4.25%D-B, 4.25%D, and 4.25%D-F. Acetaldehyde was below the lower limit (0.79 ppm) of the standard curve in 4.25%D-B and 4.25%D-F fluids but was detected (3.76 to 5.12 ppm) in all of the 4.25%D fluids. Relative levels of 5-HMF in the 4.25%D-B (0.032 to 0.041 Abs @ 284 nm) and 4.25%D (0.031 to 0.036 Abs @ 284 nm) were similar. The lowest levels (0.001 Abs @ 284 nm) were observed in the filter-sterilized 4.25%D-F. The beneficial effects of two-chambered bicarbonate lactate-buffered PD fluids on PBMC and PMN function are probably related to reduction of GDP from heat sterilization of glucose in a separate chamber at a lower pH. This improvement in biocompatibility could have a beneficial affect on peritoneal defenses.
Torri, Luisa; Piochi, Maria
2016-07-01
Despite the key role of the sensory quality for food acceptance, the aroma transfer properties of food packaging materials have not yet been studied using sensory approaches. This research investigated the suitability of sensory and electronic nose methods to evaluate the aroma transfer properties of plastic materials that come in contact with food. Four (W, X, Y, and Z) commercial freezer bags (polyethylene) for domestic uses were compared. The degree of the aroma transfer through the materials was estimated as the sensory contamination of an odor absorber food (bread) by an odor releaser food (onion), separated by the bags and stored under frozen conditions. Bread samples were analyzed by means of an electronic nose, and 42 assessors used three different sensory methods (triangle, scoring, and partial sorted Napping tests). From the triangle test, none of the plastic bags acted as a complete aroma barrier, showing a sensory contamination of bread stored in all four materials. Partial sorting Napping results clearly described the sensory contamination of bread as "onion flavor", due to the aroma transfer from the odor releaser food to the odor absorber food through the plastic bag. Scoring tests showed significant (p<0.0001) differences of aroma transfer properties among the plastic bags, revealing the highest aroma permeation for W (3.1±0.1), the lowest aroma transfer for X and Y (2.0±0.1), and intermediate aroma transfer properties for Z (2.6±0.1). Electronic nose data were in good agreement with the sensory responses, and a high correlation with the scoring data was observed (R 2 =0.988). The presented approaches had suitable results to provide meaningful information on the aroma transfer properties of freezer plastic bags, and could advantageously be applied in the future for analyzing other finished food containers (e.g. plastic trays, boxes, etc.) or packaging materials of a different nature (multilayer plastic films, biodegradable materials, composites, etc.). Copyright © 2016 Elsevier Ltd. All rights reserved.
Assessment and Management of Hypertension in Patients on Dialysis
Flynn, Joseph; Pogue, Velvie; Rahman, Mahboob; Reisin, Efrain; Weir, Matthew R.
2014-01-01
Hypertension is common, difficult to diagnose, and poorly controlled among patients with ESRD. However, controversy surrounds the diagnosis and treatment of hypertension. Here, we describe the diagnosis, epidemiology, and management of hypertension in dialysis patients, and examine the data sparking debate over appropriate methods for diagnosing and treating hypertension. Furthermore, we consider the issues uniquely related to hypertension in pediatric dialysis patients. Future clinical trials designed to clarify the controversial results discussed here should lead to the implementation of diagnostic and therapeutic techniques that improve long-term cardiovascular outcomes in patients with ESRD. PMID:24700870
Huynh, Hai P; Musselman, Reilly P; Trottier, Daniel C; Soto, Claudia M; Poulin, Eric C; Mamazza, Joseph; Boushey, Robin P; Auer, Rebecca C; Moloo, Husein
2013-10-01
To review surgical-site infection (SSI) and retrieval-site tumor recurrence rates in laparoscopic colorectal procedures when using a plastic freezer bag as a wound protector. Laparoscopic colorectal procedures where a plastic freezer bag used as a wound protector at the extraction site were reviewed between 1991 and 2008 from a prospectively collected database. χ test was used to compare SSI and tumor recurrence rates between groups. Costing data were obtained from the operating room supplies department. A total of 936 cases with 51 (5.45%) surgical-site infections were identified. SSI rates did not differ when comparing groups based on demographic factors, diagnosis, or location of procedure. Retrieval-site tumor recurrence rate was 0.21% (1/474). Cost of plastic freezer bags including sterilization ranged from $0.25 to $3. Plastic freezer bags as wound protectors in laparoscopic colorectal procedures are cost effective and have SSI and retrieval-site tumor recurrence rates that compare favorably to published data.
Guéry, Bruno; Alberti, Corinne; Servais, Aude; Harrami, Elarbi; Bererhi, Lynda; Zins, Brigitte; Touam, Malik; Joly, Dominique
2014-01-01
Objective In this clinical trial, we aimed to compare three means of performing chronic hemodialysis in patients with contra-indication to systemic heparinization. Methods This open-label monocentric randomized « n-of-one » trial, conducted in a single tertiary care center, recruited chronic hemodialysis patients with a contra-indication to systemic heparinization for at least 3 consecutive sessions. All patients underwent hemodialysis with an AN69ST dialyzer, and were administered three alternative dialysis procedures in a random sequence: intermittent saline flushes, constant saline infusion, or pre-dialysis heparin coating of the membrane. The primary outcome was the need to interrupt the dialysis session because of clotting events due to either (i) a complete coagulation of the circuit; (ii) a partial coagulation of the circuit; (iii) a>50% rise over baseline in the venous pressure. Results At the end of the inclusion period (May, 2007 to December, 2008), the number of patients to include (n = 75) was not reached: only 46 patients were included and underwent randomization. The study was terminated, and statistical analysis took into account 224 hemodialysis sessions performed in 44 patients with analyzable data. Heparin adsorption was associated with a significant reduction of the need to interrupt the dialysis session because of clotting events: odds ratio 0.3 (CI 95% 0.2 to 0.6; p<0.001, versus intermittent saline flushes). Heparin adsorption was also associated with higher odds for performing >3 h dialysis sessions and for having complete blood restitution. There were no significant effects of the dialysis procedure on weight loss, online ionic dialysance, and adverse events. Conclusion Heparin-coated AN69ST dialysis membrane is a safe and effective method to avoid or delay per-dialytic clotting events in patients with contra-indication to systemic anticoagulation. However, results are not generalizable safely to patients with active bleeding, since weak heparinemia, not assessed in this study, may occur. Trial Registration ClinicalTrials.gov NCT00473109. PMID:24825343
Sakai, M; Eguchi, K; Tezuka, H; Yamashita, I; Nakashima, M; Ida, H; Origuchi, T; Shimada, H; Kawabe, Y; Fukuda, T
1992-10-01
Secondary amyloidosis is an important complication that may have a strong influence on the prognosis of patients with rheumatoid arthritis (RA). We studied 21 RA patients with secondary amyloidosis. The two major initial signs were gastrointestinal symptoms and renal involvement. When 15 of the 21 patients were diagnosed as having secondary amyloidosis, they displayed renal involvement including proteinuria, hematuria and hypercreatininemia. The 15 patients with amyloidosis were either subjected to dialysis or died within 35 months on the average. The causes of death in 13 patients were cardiac failure, gastrointestinal bleeding and infection, which were strongly implicated with renal failure. Dialysis was applied to seven patients. Three of them were maintained with chronic dialysis. We discussed the induction-time and the method of dialysis in patients with amyloidosis secondary to RA.
Krizsan, S J; Jančík, F; Ramin, M; Huhtanen, P
2013-02-01
The objective of the present study was to compare digestion rates (kd) of NDF for different feeds estimated with the in situ method or derived from an automated gas in vitro system. A meta-analysis was conducted to evaluate how in situ derived kd of NDF related to in vivo digestibility of NDF. Furthermore, in vitro true digestibility of the feed samples incubated within filter bags or dispersed in the medium was compared, and kd for insoluble and soluble components of those feeds were estimated. Four different concentrates and 4 forages were used in this study. Two lactating Swedish Red cows fed a diet of 60% grass silage and 40% concentrate on DM basis were used for in situ incubations and for collection of rumen fluid. The feed samples were ground through a 2.0-mm screen before the in situ incubations and a 1.0-mm screen before the in vitro gas incubations. In situ nylon bags were introduced into the rumen for determination of kd of NDF. Additional kinetic data were produced from isolated NDF and intact samples subjected to in vitro incubations in which gas production was recorded for 72 h. Samples were weighed in the bottles or within filter bags (for fiber and in vitro studies) that were placed in the bottles. The interaction between feed and method was significant (P < 0.01); kd of NDF for grass hay tended (P = 0.06) to be less whereas kd of NDF for alfalfa, barley grain, canola meal, and dried sugar beet pulp were greater (P < 0.01) when estimated with the in situ method than from gas production recordings. The meta-analysis suggested that in situ derived kd of NDF were biased and underestimated in vivo digestibility of NDF. Digestion rates of the intact samples were lower for all feeds, except for the hay, when incubated within the bags compared with dispersed in the medium (P < 0.01). Less OM and NDF were digested for all feeds when incubated within bags than dispersed in the medium (P < 0.01). It is concluded from the in vitro study that microbial activity within the bags is less than in the medium. Significant interactions between method (in situ vs. in vitro) and feed suggest that one or both methods result in biased estimates of digestion kinetics.
Perl, Jeffrey; Dong, James; Rose, Caren; Jassal, Sarbjit Vanita; Gill, John S.
2013-01-01
♦ Background: Kidney transplant failure (TF) is among the leading causes of dialysis initiation. Whether survival is similar for patients treated with peritoneal dialysis (PD) and with hemodialysis (HD) after TF is unclear and may inform decisions concerning dialysis modality selection. ♦ Methods: Between 1995 and 2007, 16 113 adult dialysis patients identified from the US Renal Data System initiated dialysis after TF. A multivariable Cox proportional hazards model was used to evaluate the impact of initial dialysis modality (1 865 PD, 14 248 HD) on early (1-year) and overall mortality in an intention-to-treat approach. ♦ Results: Compared with HD patients, PD patients were younger (46.1 years vs 49.4 years, p < 0.0001) with fewer comorbidities such as diabetes mellitus (23.1% vs 25.7%, p < 0.0001). After adjustment, survival among PD patients was greater within the first year after dialysis initiation [adjusted hazard ratio (AHR): 0.85; 95% confidence interval (CI): 0.74 to 0.97], but lower after 2 years (AHR: 1.15; 95% CI: 1.02 to 1.29). During the entire period of observation, survival in both groups was similar (AHR for PD compared with HD: 1.09; 95% CI: 1.0 to 1.20). In a sensitivity analysis restricted to a cohort of 1865 propensity-matched pairs of HD and PD patients, results were similar (AHR: 1.03; 95% CI: 0.93 to 1.14). Subgroups of patients with a body mass index exceeding 30 kg/m2 [AHR: 1.26; 95% CI: 1.05 to 1.52) and with a baseline estimated glomerular filtration rate (eGFR) less than 5 mL/min/1.73 m2 (AHR: 1.45; 95% CI: 1.05 to 1.98) experienced inferior overall survival when treated with PD. ♦ Conclusions: Compared with HD, PD is associated with an early survival advantage, inferior late survival, and similar overall survival in patients initiating dialysis after TF. Those data suggest that increased initial use of PD among patients returning to dialysis after TF may be associated with improved outcomes, except among patients with a higher BMI and those who initiate dialysis at lower levels of eGFR. The reasons behind the inferior late survival seen in PD patients are unclear and require further study. PMID:24084843
Influence of long-term repeated prescribed burning on mycelial communities of ectomycorrhizal fungi.
Bastias, Brigitte A; Xu, Zhihong; Cairney, John W G
2006-01-01
To demonstrate the efficacy of direct DNA extraction from hyphal ingrowth bags for community profiling of ectomycorrhizal (ECM) mycelia in soil, we applied the method to investigate the influence of long-term repeated prescribed burning on an ECM fungal community. DNA was extracted from hyphal ingrowth bags buried in forest plots that received different prescribed burning treatments for 30 yr, and denaturing gradient gel electrophoresis (DGGE) profiles of partial fungal rDNA internal transcribed spacer (ITS) regions were compared. Restriction fragment length polymorphism (RFLP) and sequence analyses were also used to compare clone assemblages between the treatments. The majority of sequences derived from the ingrowth bags were apparently those of ECM fungi. DGGE profiles for biennially burned plots were significantly different from those of quadrennially burned and unburned control plots. Analysis of clone assemblages indicated that this reflected altered ECM fungal community composition. The results indicate that hyphal ingrowth bags represent a useful method for investigation of ECM mycelial communities, and that frequent long-term prescribed burning can influence below-ground ECM fungal communities.
Stability of Fentanyl Citrate in Polyolefin Bags.
Donnelly, Ronald F
2016-01-01
Fentanyl is used to manage pain because it is a potent lipophilic opiate agonist. The stability of fentanyl in polyolefin bags when diluted to either 10 µg/mL or 50 µg/mL with sodium chloride 0.9% has not been studied. The chemical stability of fentanyl 50 µg/mL packaged in polyvinyl chloride bags has been studied, however, the stability in polyolefin bags is lacking. Polyolefin bags were aseptically filled with either 10-µg/mL or 50-µg/mL fentanyl solution. Containers were then stored at either 5°C and protected from light or 22°C and exposed to light for 93 days. Fentanyl peaks were monitored using a stability-indicatin high-performance liquid chromatographic method. Changes to color, clarity, and pH were also monitored. There were no signs of chemical degradation of fentanyl packaged in polyolefin bags at either 5°C or 22°C after storage for 93 days. Over the course of the study, all solutions remained colorless and clear. The pH showed a slight decrease during the 93 days of storage. The stability of both undiluted (50-µg/mL) and diluted (10-µg/mL) fentanyl solutions when packaged in polyolefin bags was 93 days when stored at either 5°C or 22°C. Copyright© by International Journal of Pharmaceutical Compounding, Inc.
Coping methods to stress among patients on hemodialysis and peritoneal dialysis.
Parvan, Kobra; Ahangar, Ronak; Hosseini, Fahimeh Alsadat; Abdollahzadeh, Farahnaz; Ghojazadeh, Morteza; Jasemi, Madineh
2015-03-01
Dialysis patients need to deal and cope with various aspects of their disease. Identifying the adaptation methods provides valuable information for planning specific treatment and medical care delivery and improving the performance of medical teams. The present study aims to evaluate the coping strategies to stress among patients undergoing hemodialysis (HD) and peritoneal dialysis (PD) at the Imam Reza Educational-Medical Hospital, Tabriz, West Azarbaijan, Iran. This descriptive and analytical study was conducted on 70 patients in the year 2012. The subjects were selected through census method and simple random sampling method. Data were collected using a customized questionnaire and consisted of demographic information and the Jalowiec Coping Scale (JCS) through a structured interview. Descriptive and inferential statistics were used to analyze the data in SPSS (version 13). The mean score of frequency of use of the coping strategy as "sometimes used" for the HD patients was 70.94 ± 18.91 and also for PD patients as "seldom used" was 58.70 ± 12.66. The mean score of helpfulness of coping strategies in the HD group was 49.57 ± 19.42 as "slightly helpful", whereas in the PD group it was 37.21 ± 14.38 as "slightly helpful" Furthermore, both groups used the emotion-oriented coping styles more frequently than the problem-oriented methods. HD patients used coping methods more frequently than the PD patients. The majority of patients used emotion-oriented coping strategies to deal with stress factors. Use of educational, counseling and supportive programs to assist in coping techniques can facilitate the coping process with stress factors in dialysis patients.
Drawbacks of Dialysis Procedures for Removal of EDTA
Mónico, Andreia; Martínez-Senra, Eva; Cañada, F. Javier; Zorrilla, Silvia
2017-01-01
Ethylenediaminetetraacetic acid (EDTA) is a chelating agent commonly used in protein purification, both to eliminate contaminating divalent cations and to inhibit protease activity. For a number of subsequent applications EDTA needs to be exhaustively removed. Most purification methods rely in extensive dialysis and/or gel filtration in order to exchange or remove protein buffer components, including metal chelators. We report here that dialysis protocols, even as extensive as those typically employed for protein refolding, may not effectively remove EDTA, which is reduced only by approximately two-fold and it also persists after spin-column gel filtration, as determined by NMR and by colorimetric methods. Remarkably, the most efficient removal was achieved by ultrafiltration, after which EDTA became virtually undetectable. These results highlight a potentially widespread source of experimental variability affecting free divalent cation concentrations in protein applications. PMID:28099451
Osono, Eiichi; Kobayashi, Eiko; Inoue, Yuki; Honda, Kazumi; Kumagai, Takuya; Negishi, Hideki; Okamatsu, Kentaro; Ichimura, Kyoko; Kamano, Chisako; Suzuki, Fumi; Norose, Yoshihiko; Takahashi, Megumi; Takaku, Shun; Fujioka, Noriaki; Hayama, Naoaki; Takizawa, Hideaki
2014-01-01
A chemiluminescence system, Milliflex Quantum (MFQ), to detect microcolonies, has been used in the pharmaceutical field. In this study, we investigated aquatic bacteria in hemodialysis solutions sampled from bioburden areas in 4 dialysis faculties. Using MFQ, microcolonies could be detected after a short incubation period. The colony count detected with MFQ after a 48-hour incubation was 92% ± 39%, compared to that after the conventionally used 7-14-day incubation period; in addition, the results also showed a linear correlation. Moreover, MFQ-based analysis allowed the visualization of damaged cells and of the high density due to the excessive amount of bacteria. These results suggested that MFQ had adequate sensitivity to detect microbacteria in dialysis solutions, and it was useful for validating the conditions of conventional culture methods.
González-Rodríguez, M L; Barros, L B; Palma, J; González-Rodríguez, P L; Rabasco, A M
2007-06-07
In this paper, we have used statistical experimental design to investigate the effect of several factors in coating process of lidocaine hydrochloride (LID) liposomes by a biodegradable polymer (chitosan, CH). These variables were the concentration of CH coating solution, the dripping rate of this solution on the liposome colloidal dispersion, the stirring rate, the time since the liposome production to the liposome coating and finally the amount of drug entrapped into liposomes. The selected response variables were drug encapsulation efficiency (EE, %), coating efficiency (CE, %) and zeta potential. Liposomes were obtained by thin-layer evaporation method. They were subsequently coated with CH according the experimental plan provided by a fractional factorial (2(5-1)) screening matrix. We have used spectroscopic methods to determine the zeta potential values. The EE (%) assay was carried out in dialysis bags and the brilliant red probe was used to determine CE (%) due to its property of forming molecular complexes with CH. The graphic analysis of the effects allowed the identification of the main formulation and technological factors by the analysis of the selected responses and permitted the determination of the proper level of these factors for the response improvement. Moreover, fractional design allowed quantifying the interactions between the factors, which will consider in next experiments. The results obtained pointed out that LID amount was the predominant factor that increased the drug entrapment capacity (EE). The CE (%) response was mainly affected by the concentration of the CH solution and the stirring rate, although all the interactions between the main factors have statistical significance.
Evaluating Infection Prevention Strategies in Out-Patient Dialysis Units Using Agent-Based Modeling.
Wares, Joanna R; Lawson, Barry; Shemin, Douglas; D'Agata, Erika M C
2016-01-01
Patients receiving chronic hemodialysis (CHD) are among the most vulnerable to infections caused by multidrug-resistant organisms (MDRO), which are associated with high rates of morbidity and mortality. Current guidelines to reduce transmission of MDRO in the out-patient dialysis unit are targeted at patients considered to be high-risk for transmitting these organisms: those with infected skin wounds not contained by a dressing, or those with fecal incontinence or uncontrolled diarrhea. Here, we hypothesize that targeting patients receiving antimicrobial treatment would more effectively reduce transmission and acquisition of MDRO. We also hypothesize that environmental contamination plays a role in the dissemination of MDRO in the dialysis unit. To address our hypotheses, we built an agent-based model to simulate different treatment strategies in a dialysis unit. Our results suggest that reducing antimicrobial treatment, either by reducing the number of patients receiving treatment or by reducing the duration of the treatment, markedly reduces overall colonization rates and also the levels of environmental contamination in the dialysis unit. Our results also suggest that improving the environmental decontamination efficacy between patient dialysis treatments is an effective method for reducing colonization and contamination rates. These findings have important implications for the development and implementation of future infection prevention strategies.
The Experience of Older People in the Shared Decision-Making Process in Advanced Kidney Care
Jenkins, Karen; McManus, Breeda; Gracey, Brian
2016-01-01
Introduction. This qualitative descriptive study was designed to understand the experiences of older people (>70 years) when making a decision about renal replacement therapy. This was a coproduced study, whereby patients and carers were involved in all aspects of the research process. Methods. A Patient and Carer Group undertook volunteer and research training. The group developed the interview questions and interviewed 29 people who had commenced dialysis or made a decision not to have dialysis. Interview data were transcribed and analysed, and common themes were identified. Results. 22 men and 7 women (mean age 77.4 yrs) from two hospitals were interviewed. 18 had chosen haemodialysis, 6 peritoneal dialysis, and 5 supportive care. The majority of patients were involved in the dialysis decision. Most were satisfied with the amount of information that they received, although some identified that the quality of the information could be improved, especially how daily living can be affected by dialysis. Conclusion. Our findings show that overall older patients were involved in the dialysis decision along with their families. Our approach is innovative because it is the first time that patients and carers have been involved in a coproduced study about shared decision-making. PMID:27990438
Algae Bioreactor Using Submerged Enclosures with Semi-Permeable Membranes
NASA Technical Reports Server (NTRS)
Flynn, Michael T (Inventor); Baertsch, Robert (Inventor); Trent, Jonathan D (Inventor); Liggett, Travis A (Inventor); Gormly, Sherwin J (Inventor); Delzeit, Lance D (Inventor); Buckwalter, Patrick W (Inventor); Embaye, Tsegereda N (Inventor)
2013-01-01
Methods for producing hydrocarbons, including oil, by processing algae and/or other micro-organisms in an aquatic environment. Flexible bags (e.g., plastic) with CO.sub.2/O.sub.2 exchange membranes, suspended at a controllable depth in a first liquid (e.g., seawater), receive a second liquid (e.g., liquid effluent from a "dead zone") containing seeds for algae growth. The algae are cultivated and harvested in the bags, after most of the second liquid is removed by forward osmosis through liquid exchange membranes. The algae are removed and processed, and the bags are cleaned and reused.
Gas diffusion liquid storage bag and method of use for storing blood
NASA Technical Reports Server (NTRS)
Bank, H.; Cleland, E. L. (Inventor)
1979-01-01
The shelf life of stored whole blood may be doubled by adding a buffer which maintains a desired pH level. However, this buffer causes the generation of CO2 which, if not removed at a controlled rate, causes the pH value of the blood to decrease, which shortens the useful life of the blood. A blood storage bag is described which permits the CO2 to be diffused out at a controlled rate into the atmosphere, thereby maintaining the desired pH value and providing a bag strong enough to permit handling.
NASA Technical Reports Server (NTRS)
Oza, Nikunji C.
2005-01-01
Bagging and boosting are two of the most well-known ensemble learning methods due to their theoretical performance guarantees and strong experimental results. However, these algorithms have been used mainly in batch mode, i.e., they require the entire training set to be available at once and, in some cases, require random access to the data. In this paper, we present online versions of bagging and boosting that require only one pass through the training data. We build on previously presented work by presenting some theoretical results. We also compare the online and batch algorithms experimentally in terms of accuracy and running time.
Use of Vacuum Bagging for Fabricating Thermoplastic Microfluidic Devices
Cassano, Christopher L.; Simon, Andrew J.; Liu, Wei; Fredrickson, Carl; Fan, Z. Hugh
2014-01-01
In this work we present a novel thermal bonding method for thermoplastic microfluidic devices. This simple method employs a modified vacuum bagging technique, a concept borrowed from the aerospace industry, to produce conventional thick substrate microfluidic devices, as well as multi-layer film devices. The bonds produced using this method are superior to those obtained using conventional thermal bonding methods, including thermal lamination, and are capable of sustaining burst pressures in excess of 550 kPa. To illustrate the utility of this method, thick substrate devices were produced, as well as a six-layer film device that incorporated several complex features. PMID:25329244
Totaro, M; Casini, B; Valentini, P; Miccoli, M; Giorgi, S; Porretta, A; Privitera, G; Lopalco, P L; Baggiani, A
2017-10-01
Patients receiving haemodialysis are exposed to a large volume of dialysis fluid. The Italian Society of Nephrology (ISN) has published guidelines and microbial quality standards on dialysis water (DW) and solutions to ensure patient safety. To identify microbial and chemical hazards, and evaluate the quality of disinfection treatment in DW plants. In 2015 and 2016, water networks and DW plants (closed loop and online monitors) of nine dialysis wards of Italian hospitals, hosting 162 dialysis beds overall, were sampled on a monthly basis to determine the parameters provided by ISN guidelines. Chlorinated drinking water was desalinated by reverse osmosis and distributed to the closed loop which feeds all online monitors. Disinfection with peracetic acid was performed in all DW plants on a monthly basis. Over the 24-month study period, seven out of nine DW plants (78%) recorded negative results for all investigated parameters. Closed loop contamination with Burkholderia cepacia was detected in a DW plant from January 2015 to March 2015. Pseudomonas aeruginosa was isolated from March 2016 to May 2016 in the closed loop of another DW plant. These microbial contaminations were eradicated by shock disinfection with sodium hypochlorite and peracetic acid, followed by water flushing. These results highlight the importance of chemical and physical methods of DW disinfection. The maintenance of control measures in water plants hosted in dialysis wards ensures a microbial risk reduction for all dialysis patients. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Brown, Edwina A.; Johansson, Lina; Farrington, Ken; Gallagher, Hugh; Sensky, Tom; Gordon, Fabiana; Da Silva-Gane, Maria; Beckett, Nigel; Hickson, Mary
2010-01-01
Background. Health-related quality of life (QOL) is an important outcome for older people who are often on dialysis for life. Little is, however, known about differences in QOL on haemodialysis (HD) and peritoneal dialysis (PD) in older age groups. Randomising patients to either modality to assess outcomes is not feasible. Methods. In this cross-sectional, multi-centred study we conducted QOL assessments (Short Form-12 Mental and Physical Component Summary scales, Hospital Anxiety and Depression Scale and Illness Intrusiveness Ratings Scale) in 140 people (aged 65 years or older) on PD and HD. Results. The groups were similar in age, gender, time on dialysis, ethnicity, Index of Deprivation (based on postcode), dialysis adequacy, cognitive function (Mini-Mental State Exam and Trail-Making Test B), nutritional status (Subjective Global Assessment) and social networks. There was a higher comorbidity score in the HD group. Regression analyses were undertaken to ascertain which variables significantly influence each QOL assessment. All were influenced by symptom count highlighting that the patient’s perception of their symptoms is a critical determinant of their mental and physical well being. Modality was found to be an independent predictor of illness intrusion with greater intrusion felt in those on HD. Conclusions. Overall, in two closely matched demographic groups of older dialysis patients, QOL was similar, if not better, in those on PD. This study strongly supports offering PD to all suitable older people. PMID:20400451
Relationship between cognitive impairment and depression in dialysis patients.
Jung, San; Lee, Young-Ki; Choi, Sun Ryoung; Hwang, Sung-Hee; Noh, Jung-Woo
2013-11-01
Patients with chronic kidney disease frequently show cognitive dysfunction. The association of depression and cognitive function is not well known in maintenance dialysis patients. We evaluated cognitive impairment and depression, as well as their relationship in regards to methods of dialysis, maintenance hemodialysis (MHD) and chronic peritoneal dialysis (CPD). Fifty-six maintenance dialysis patients were recruited and their clinical and laboratory data were collected. The Korean version of the mini-mental state exam (K-MMSE) was applied to screen the patient's cognitive function, while the Korean version of the Beck Depression Inventory (K-BDI) was used for depression screening. The average age of the participants was 54.2±10.2 years; 29 (51.8%) were female. The average dialysis vintage was 4.2±3.8 years. The CPD group showed significantly higher K-MMSE score (27.8±2.9 vs. 26.1±3.1, p=0.010) and lower K-BDI score (12.0±8.4 vs. 20.2±10.4, p=0.003) compared with the MHD group. The percentage of patients with depression symptoms was higher in the MHD group (51.7% vs. 18.5%). There was a negative correlation between cognitive function and prevalence of depressive symptoms. Depression and education level were shown to be independent predictors for cognitive impairment in multivariate analysis. Cognitive impairment was closely correlated with depression. It is important to detect cognitive impairment and depression early in maintenance dialysis patients with simple bedside screening tools.
Egas-Kitchener, Sara; Whibley, Daniel; Fynmore, Tom; Jones, Gareth D.
2017-01-01
Abstract Background Benefits of exercise on dialysis (EOD) are well established, however, uptake in our local satellite haemodialysis units is low. The implications of the status quo are risks to treatment efficiency, equity and patient centredness in managing personal health risks. The current study aimed to identify and address barriers to exercise participation while on dialysis by substantiating local EOD risks, assigning context, implementing changes and evaluating their impact. Our primary objective was to increase the uptake of EOD across our five dialysis units. Methods Semi-structured interview and questionnaire data from patients and nursing staff were used to inform a root-cause analysis of barriers to exercise participation while on dialysis. Intervention was subsequently designed and implemented by a senior physiotherapist. It consisted of patient and nursing staff education, equipment modification and introduction of patient motivation schemes. Results Staff knowledge, patient motivation and equipment problems were the main barriers to EOD. A significant increase in the uptake of EOD from 23.3% pre-intervention to 74.3% post-intervention was achieved [χ2 (1, N = 174) = 44.18, P < 0.001]. Conclusions Barriers to EOD are challenging, but there is evidence that patients wish to participate and would benefit from doing so. The input of a physiotherapist in the dialysis units had a significant positive effect on the uptake of EOD. National guidelines should encourage dialysis units to include professional exercise provision in future service planning. PMID:28852491
The impact on quality of life of dialysis patients with renal insufficiency.
Dąbrowska-Bender, Marta; Dykowska, Grażyna; Żuk, Wioletta; Milewska, Magdalena; Staniszewska, Anna
2018-01-01
The aim of the study was the subjective assessment of the quality of life (QoL) of 140 patients treated with dialysis (peritoneal dialysis and hemodialysis). Chronic kidney disease and the methods of its treatment play an important part in shaping the QoL of patients receiving dialysis. As a result, kidney failure causes many limitations in patients' physical, mental, and social activities. The instrument to measure the QoL was the authors' own questionnaire made on the basis of Kidney Disease and Quality of Life Short Form version 1.2 (KDQOL - SF 1.2) and their selection of areas influencing the perceived QoL of chronically ill patients. The research showed that patients receiving peritoneal dialysis assessed their QoL in its different dimensions as much higher than patients receiving hemodialysis. The parameter having the biggest negative impact on the QoL of patients receiving hemodialysis was an impeded possibility to continue work or studies and a change of life plans. The will to live was more highly assessed by patients receiving peritoneal dialysis as compared to patients receiving hemodialysis. In order to improve the functioning of hemodialysis patients in a manner most similar to healthy persons, the renal replacement therapy should consider patients' individual needs and expectations, ie, guarantee flexible hours of work or study and of receiving dialysis. In addition, patients treated with hemodialysis should receive psychological care, in particular those demonstrating emotional problems, in order to achieve better results in therapy and improve their QoL.
Shen, Jenny I; Lum, Erik L; Chang, Tara I
2016-09-01
Because large randomized clinical trials (RCTs) in dialysis have been relatively scarce, evidence-based dialysis care has depended heavily on the results of observational studies. However, when results from RCTs appear to contradict the findings of observational studies, nephrologists are left to wonder which type of study they should believe. In this editorial, we explore the key differences between observational studies and RCTs in the context of such seemingly conflicting studies in dialysis. Confounding is the major limitation of observational studies, whereas low statistical power and problems with external validity are more likely to limit the findings of RCTs. Differences in the specification of the population, exposure, and outcomes can also contribute to different results among RCTs and observational studies. Rigorous methods are required regardless of what type of study is conducted, and readers should not automatically assume that one type of study design is superior to the other. Ultimately, dialysis care requires both well-designed, well-conducted observational studies and RCTs to move the field forward. © 2016 Wiley Periodicals, Inc.
Shen, Jenny I.; Lum, Erik L.; Chang, Tara I.
2016-01-01
Because large randomized clinical trials (RCTs) in dialysis have been relatively scarce, evidence-based dialysis care has depended heavily on the results of observational studies. However, when results from RCTs appear to contradict the findings of observational studies, nephrologists are left to wonder which type of study they should believe. In this editorial we explore the key differences between observational studies and RCTs in the context of such seemingly conflicting studies in dialysis. Confounding is the major limitation of observational studies, while low statistical power and problems with external validity are more likely to limit the findings of RCTs. Differences in the specification of the population, exposure, and outcomes can also contribute to different results among RCTs and observational studies. Rigorous methods are required regardless of what type of study is conducted, and readers should not automatically assume that one type of study design is superior to the other. Ultimately, dialysis care requires both well-designed, well-conducted observational studies and RCTs to move the field forward. PMID:27207819
OuYang, Xiao-Kun; Luo, Yu-Yang; Wang, Yang-Guang; Yang, Li-Ye
2014-01-01
The simultaneous determination of five aromatic amines and their potential migration from packaging bags into seafood simulants were investigated. A validated HPLC method was developed for the separation and qualification of five aromatic amines in seafood simulants. By combining solid-phase extraction (SPE), these amines were efficiently separated on a Halo C18 column (150 × 4.6 mm i.d., 2.7 μm, particle size) using a mobile phase of methanol/phosphate buffer solution (5 mmol l(-1), pH 6.9) with gradient elution. The linear range was 0.1-10.0 mg l(-1); the absolute recoveries ranged from 85.3% to 98.4%; and the limits of detection of the five aromatic amines were between 0.015 and 0.08 mg l(-1). In this work the migration profile of aromatic amines from black plastic bags was investigated at temperatures of 4°C with water, 3% acetic acid solution, 10% ethanol solution and 50% ethanol solution as seafood simulants, respectively. The migration of the five aromatic amines under different conditions showed that residual o-methoxyaniline, p-chloroaniline, aniline and 2,6-dimethylaniline leaching from black plastic bags increased with incubation time. No detectable 3,3´-dimethylbenzidine was found to leach from the bags.
da Silva Fernandes, Natália Maria; Bastos, Marcus Gomes; Franco, Márcia Regina Gianotti; Chaoubah, Alfredo; da Glória Lima, Maria; Divino-Filho, José Carolino; Qureshi, Abdul Rashid
2013-01-01
OBJECTIVES: To determine the roles of body size and longitudinal body weight changes in the survival of incident peritoneal dialysis patients. PATIENTS AND METHODS: Patients (n = 1911) older than 18 years of age recruited from 114 dialysis centers (Dec/2004-Oct/2007) and participating in the Brazilian Peritoneal Dialysis Multicenter Cohort Study were included. Clinical and laboratory data were collected monthly (except if the patient received a transplant, recovered renal function, was transferred to hemodialysis, or died). RESULTS: Survival analyses were performed using Kaplan-Meier survival curves and Cox proportional hazards. Total follow-up was 34 months. The mean age was 59 years (54% female). The weight category percentages were as follows: underweight: 8%; normal: 51%; overweight: 29%; and obese 12%. The multivariate model showed a higher risk of death for a body mass index <18.5 kg/m2, a neutral risk between 25 and 29.9 kg/m2 and a protective effect for an index >30 kg/m2. Patients were divided into five categories according to quintiles of body weight changes during the first year of dialysis: <−3.1%, −3.1 to+0.12%, +0.12 to <+3.1% (reference category), +3.1 to +7.1% and >+7.1%. Patients in the lowest quintile had significantly higher mortality, whereas no negative impact was observed in the other quintiles. CONCLUSION: These findings suggest that overweight/obesity and a positive body weight variation during the first year of peritoneal dialysis therapy do not increase mortality in incident dialysis patients in Brazil. PMID:23420157
Bioimpacts of dialyzer variety on phosphorus level in Iranian hemodialysis patients
Pezeshgi, Aiyoub; Moharrami, Bahareh; Kolifarhood, Goodarz; Sadeghi, Alireza; Asadi-Khiavi, Masoud
2016-01-01
Introduction: Cardiovascular events are the major cause of death in patients with chronic renal failure. About half of dialysis patients because of reduced phosphorus clearance have hyperphosphatemia. Hyperphosphatemia and following secondary hyperparathyroidism lead to some cardiovascular changes. Hemodialysis (HD) partly removes phosphorus during each dialysis session. Objectives: Presented study was designed to evaluate dialyzer variation effect on phosphorus level as a prognostic factor after dialysis using. Materials and Methods: Six kinds of dialyzer were used for dialysis; low flux (LF) dialyzer (F7 and F8), high flux (HF) dialyzer (F70 and F80) and finally hollow-fiber dialyzers including polyethersulfone (PES) 130 HF and polysulfone (PS) 13 LF. Fifty-seven patients were divided into 6 matched groups included three groups of 10 people and 3 groups of 9 persons in groups: A (F70), B (F80), C (F7), D (F8), E (PES 130 HF) and F (PS 13 LF). Patients were treated for one month with these dialyzers. At the end of the month, blood samples were taken again for phosphorus level before dialysis handling. Results: The mean pre-dialysis serum phosphorus was 5.03, 5.4, 5.2, 4.6, 4.95 and 5.1 mg/dl and the mean phosphorus was 5.43, 5.01, 4.9, 4.18, 4.17 and 5.3 mg/dl after one month of dialysis, respectively in groups A to F without any statistically differences between pre- and after one month dialysis values respectively. Discussion: The findings indicate dialyzer type in the control of serum phosphorus has not been effective in the short-term HD. We suggest a study with more duration time. PMID:27471742
[Stents in dialysis vascular access--do they promise improved high quality prolonged access use].
Klein, Osnat; Plotkin, Eleonora; Gritun, Igal; Verner, Myriam; Lehmann, J M; Rathaus, Mauro; Bernheim, Jacques
2008-02-01
The life expectancy of dialysis patients depends, to a large extent, on blood access which provides uninterrupted and efficient treatment. Dialysis access created by a direct anastomosis between artery and vein usually allows normal dialysis for many years. Blood access by a bridge graft between artery and vein functions for a much shorter time and occludes chiefly because of endothelial hyperplasia at the graft vein anastomosis. This type of fistula is created when the veins of the patient are small. During the last few years the dialysis population is increasingly composed of adult and elderly patients suffering from diabetes mellitus, hypertension, dyslipidemias and atheromatous vascular disease so that a relatively large proportion of dialysis accesses are created using a bridge graft. Since we currently do not have the knowledge of how to arrest or delay the processes which lead to access occlusion, attempts are made to implement prophylactic strategies, find stenoses and dilate them before the access fails. Up to date, controlled trials have not succeeded in proving that this method prolongs access use. These trials did not describe the use of stents following dilatation. Between July 2002 and May 2005, 238 angiographies were performed on blood accesses including 179 angioplasties of stenoses. In sixteen patients a stent was deployed during the angioplasty. In ten patients dialysis was performed using the same access up to the end of the study period, an average of 43 months from the creation of the access. Three patients died with a functioning access and in three the access occluded during the period of followup. This study shows that the use of stents following angioplasty of dialysis access stenoses can improve the duration of use of accesses created through grafts.
The initial impact of Medicare's new prospective payment system for kidney dialysis.
Hirth, Richard A; Turenne, Marc N; Wheeler, John R C; Nahra, Tammie A; Sleeman, Kathryn K; Zhang, Wei; Messana, Joseph A
2013-10-01
Medicare implemented a new prospective payment system (PPS) on January 1, 2011. This PPS covers an expanded bundle of services, including services previously paid on a fee-for-service basis. The objectives of the new PPS include more efficient decisions about treatment service combinations and modality choice. Primary data for this study are Medicare claims files for all dialysis patients for whom Medicare is the primary payer. We compare use of key injectable medications under the bundled PPS to use when those drugs were separately billable and examine variability across providers. We also compare each patient's dialysis modality before and after the PPS. Use of relatively expensive drugs, including erythropoiesis-stimulating agents, declined substantially after institution of the new PPS, whereas use of iron products, often therapeutic substitutes for erythropoiesis-stimulating agents, increased. Less expensive vitamin D products were substituted for more expensive types. Drug spending overall decreased by ∼$25 per session, or about 5 times the mandated reduction in the base payment rate of ∼$5. Use of peritoneal dialysis increased in 2011 after being nearly flat in the years prior to the PPS, with the increase concentrated in patients in their first or second year of dialysis. Home hemodialysis continued to increase as a percentage of total dialysis services, but at a rate similar to the pre-PPS trend. The expanded bundle dialysis PPS provided incentives for the use of lower cost therapies. These incentives seem to have motivated dialysis providers to move toward lower cost methods of care in both their use of drugs and choice of modalities. Copyright © 2013 National Kidney Foundation, Inc. All rights reserved.
Kim, Hyung Wook; Kim, Su-Hyun; Kim, Young Ok; Jin, Dong Chan; Song, Ho Chul; Choi, Euy Jin; Kim, Yong-Lim; Kim, Yon-Su; Kang, Shin-Wook; Kim, Nam-Ho; Yang, Chul Woo; Kim, Yong Kyun
2014-01-01
Background The effect of flux membranes on mortality in hemodialysis (HD) patients is controversial. Residual renal function (RRF) has shown to not only be as a predictor of mortality but also a contributor to β2-microglobulin clearance in HD patients. Our study aimed to determine the interaction of residual renal function with dialyzer membrane flux on mortality in HD patients. Methods HD Patients were included from the Clinical Research Center registry for End Stage Renal Disease, a prospective observational cohort study in Korea. Cox proportional hazards regression models were used to study the association between use of high-flux dialysis membranes and all-cause mortality with RRF and without RRF. The primary outcome was all-cause mortality. Results This study included 893 patients with 24 h-residual urine volume ≥100 ml (569 and 324 dialyzed using low-flux and high-flux dialysis membranes, respectively) and 913 patients with 24 h-residual urine volume <100 ml (570 and 343 dialyzed using low-flux and high-flux dialysis membranes, respectively). After a median follow-up period of 31 months, mortality was not significantly different between the high and low-flux groups in patients with 24 h-residual urine volume ≥100 ml (HR 0.86, 95% CI, 0.38–1.95, P = 0.723). In patients with 24 h-residual urine volume <100 ml, HD using high-flux dialysis membrane was associated with decreased mortality compared to HD using low-flux dialysis membrane in multivariate analysis (HR 0.40, 95% CI, 0.21–0.78, P = 0.007). Conclusions Our data showed that HD using high-flux dialysis membranes had a survival benefit in patients with 24 h-residual urine volume <100 ml, but not in patients with 24 h-residual urine volume ≥100 ml. These findings suggest that high-flux dialysis rather than low-flux dialysis might be considered in HD patients without RRF. PMID:24906205
Rossignol, Patrick; Dorval, Marc; Fay, Renaud; Ros, Joan Fort; Loughraieb, Nathalie; Moureau, Frédérique; Laville, Maurice
2013-06-01
Anticoagulation for chronic dialysis patients with contraindications to heparin administration is challenging. Current guidelines state that in patients with increased bleeding risks, strategies that can induce systemic anticoagulation should be avoided. Heparin-free dialysis using intermittent saline flushes is widely adopted as the method of choice for patients at risk of bleeding, although on-line blood predilution may also be used. A new dialyzer, Evodial (Gambro, Lund, Sweden), is grafted with unfractionated heparin during the manufacturing process and may allow safe and efficient heparin-free hemodialysis sessions. In the present trial, Evodial was compared to standard care with either saline flushes or blood predilution. The HepZero study is the first international (seven countries), multicenter (10 centers), randomized, controlled, open-label, non-inferiority (and if applicable subsequently, superiority) trial with two parallel groups, comprising 252 end-stage renal disease patients treated by maintenance hemodialysis for at least 3 months and requiring heparin-free dialysis treatments. Patients will be treated during a maximum of three heparin-free dialysis treatments with either saline flushes or blood predilution (control group), or Evodial. The first heparin-free dialysis treatment will be considered successful when there is: no complete occlusion of air traps or dialyzer rendering dialysis impossible; no additional saline flushes to prevent clotting; no change of dialyzer or blood lines because of clotting; and no premature termination (early rinse-back) because of clotting.The primary objectives of the study are to determine the effectiveness of the Evodial dialyzer, compared with standard care in terms of successful treatments during the first heparin-free dialysis. If the non-inferiority of Evodial is demonstrated then the superiority of Evodial over standard care will be tested. The HepZero study results may have major clinical implications for patient care. ClinicalTrials.gov NCT01318486.
Association between GFR Estimated by Multiple Methods at Dialysis Commencement and Patient Survival
Wong, Muh Geot; Pollock, Carol A.; Cooper, Bruce A.; Branley, Pauline; Collins, John F.; Craig, Jonathan C.; Kesselhut, Joan; Luxton, Grant; Pilmore, Andrew; Harris, David C.
2014-01-01
Summary Background and objectives The Initiating Dialysis Early and Late study showed that planned early or late initiation of dialysis, based on the Cockcroft and Gault estimation of GFR, was associated with identical clinical outcomes. This study examined the association of all-cause mortality with estimated GFR at dialysis commencement, which was determined using multiple formulas. Design, setting, participants, & measurements Initiating Dialysis Early and Late trial participants were stratified into tertiles according to the estimated GFR measured by Cockcroft and Gault, Modification of Diet in Renal Disease, or Chronic Kidney Disease-Epidemiology Collaboration formula at dialysis commencement. Patient survival was determined using multivariable Cox proportional hazards model regression. Results Only Initiating Dialysis Early and Late trial participants who commenced on dialysis were included in this study (n=768). A total of 275 patients died during the study. After adjustment for age, sex, racial origin, body mass index, diabetes, and cardiovascular disease, no significant differences in survival were observed between estimated GFR tertiles determined by Cockcroft and Gault (lowest tertile adjusted hazard ratio, 1.11; 95% confidence interval, 0.82 to 1.49; middle tertile hazard ratio, 1.29; 95% confidence interval, 0.96 to 1.74; highest tertile reference), Modification of Diet in Renal Disease (lowest tertile hazard ratio, 0.88; 95% confidence interval, 0.63 to 1.24; middle tertile hazard ratio, 1.20; 95% confidence interval, 0.90 to 1.61; highest tertile reference), and Chronic Kidney Disease-Epidemiology Collaboration equations (lowest tertile hazard ratio, 0.93; 95% confidence interval, 0.67 to 1.27; middle tertile hazard ratio, 1.15; 95% confidence interval, 0.86 to 1.54; highest tertile reference). Conclusion Estimated GFR at dialysis commencement was not significantly associated with patient survival, regardless of the formula used. However, a clinically important association cannot be excluded, because observed confidence intervals were wide. PMID:24178976
ERIC Educational Resources Information Center
Renfro, Nancy
1983-01-01
Thirteen ideas for using paper bags for class art activities are given. Directions for making bag barracudas, bionic bags, bigfoot bags, bag sculptures, bag beads, and body bag superstars are included. (PP)
Nutrition in children with CRF and on dialysis
Shaw, Vanessa
2007-01-01
The objectives of this study are: (1) to understand the importance of nutrition in normal growth; (2) to review the methods of assessing nutritional status; (3) to review the dietary requirements of normal children throughout childhood, including protein, energy, vitamins and minerals; (4) to review recommendations for the nutritional requirements of children with chronic renal failure (CRF) and on dialysis; (5) to review reports of spontaneous nutritional intake in children with CRF and on dialysis; (6) to review the epidemiology of nutritional disturbances in renal disease, including height, weight and body composition; (7) to review the pathological mechanisms underlying poor appetite, abnormal metabolic rate and endocrine disturbances in renal disease; (8) to review the evidence for the benefit of dietetic input, dietary supplementation, nasogastric and gastrostomy feeds and intradialytic nutrition; (9) to review the effect of dialysis adequacy on nutrition; (10) to review the effect of nutrition on outcome. PMID:17216263
Nonadherence in dialysis patients: prevalence, measurement, outcome, and psychological determinants.
Clark, Sarah; Farrington, Ken; Chilcot, Joseph
2014-01-01
Nonadherence to aspects of the management of End-Stage Kidney Disease (ESKD) is common. Estimates of nonadherence vary with assessment method. Whilst readily available and free from report bias, physiological proxies-frequently used as measures of adherence-are often confounded by clinical factors including residual kidney function and dialysis adequacy. Despite variation in estimates of its prevalence, it is clear that suboptimal adherence to dialysis prescriptions, medication and diet can lead to adverse clinical outcomes. Several factors can help explain nonadherence in ESKD including mood, self-efficacy, social support, illness, and treatment perceptions. Psychological interventions have been shown to improve ESKD adherence, yet achieving long-term behavior change remains challenging. Identifying individuals who struggle to adhere to aspects of the dialysis regime, and tailoring theory-led interventions to improve and support adherence is a clear clinical need requiring further empirical enquiry. © 2013 Wiley Periodicals, Inc.
Apparatus for molecular weight separation
Smith, Richard D.; Liu, Chuanliang
2001-01-01
The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations (0-2.5 mM NH4OAc) of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, (4) conducting a two-stage separation or (5) any combination of (1), (2), (3) and (4).
Microdialysis unit for molecular weight separation
Smith, Richard D.; Liu, Chuanliang
1999-01-01
The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations (0-2.5 mM NH4OAc) of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, or (4) any combination of (1), (2), and (3).
USDA-ARS?s Scientific Manuscript database
Cooking or reheating food in a vacuum-sealed bag has been a common method of preparing vegetables, meats and poultry products. However, there are very few examples of vacuum-sealed bags designed for cooking or reheating catfish fillets. The objective of the present study was to examine the propert...
Thompson, Stephanie; Manns, Braden; Lloyd, Anita; Hemmelgarn, Brenda; MacRae, Jennifer; Klarenbach, Scott; Unsworth, Larry; Courtney, Mark; Tonelli, Marcello
2017-05-01
Dietary restriction and phosphate binders are the main interventions used to manage hyperphosphatemia in people on hemodialysis, but have limited efficacy. Modifying conventional dialysis regimens to enhance phosphate clearance as an alternative approach remains relatively unstudied. This was a 10-week, 2-arm, randomized crossover study. Participants were prevalent dialysis patients ( n = 32) with consecutive serum phosphate levels >1.6 mmol/L and on stable doses of a phosphate binder. Following a 2-week run-in period, participants were randomized to initiate dialysis using two high flux dialyzers in parallel (blood flow ≥350 mL/min, dialysate flow 800 mL/min) or standard dialysis using one high flux dialyzer (blood flow ≥350 mL/min, dialysate flow of 800 mL/min). Each regimen was 3 weeks in duration. After a 2-week washout period, participants received the alternate regimen. The primary outcome was the mean difference in phosphate clearance by dialyzer strategy. Secondary outcomes were phosphate removal and pre-dialysis serum phosphate. Phosphate clearance for the double dialyzer strategy did not differ significantly from the single dialyzer strategy [mean difference 7.5 mL/min (95% confidence interval, 95% CI, -6.1, 21.0), P = 0.28]. There was no difference in total phosphate removal and pre-dialysis phosphate between the double and single dialyzer strategies [total phosphate removal mean difference -0.2 mmol (95% CI -4.1, 3.7), P = 0.93; pre-dialysis mean difference 0.01 mmol/L (95% CI -0.18, 0.21), P = 0.88]. There was no difference in the proportion of participants who experienced at least one episode of intradialytic hypotension (32 versus 47%, P = 0.13). A limitation of the study was frequent protocol deviations in the dialysis prescription. In this study, the use of two dialyzers in parallel did not increase phosphate clearance, phosphate removal or pre-dialysis serum phosphorus when compared with a standard dialysis treatment strategy. Future studies should continue to evaluate novel methods of phosphate removal using conventional hemodialysis. © The Author 2016. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.
Morton, Rachael L.; Snelling, Paul; Webster, Angela C.; Rose, John; Masterson, Rosemary; Johnson, David W.; Howard, Kirsten
2012-01-01
Background: For every patient with chronic kidney disease who undergoes renal-replacement therapy, there is one patient who undergoes conservative management of their disease. We aimed to determine the most important characteristics of dialysis and the trade-offs patients were willing to make in choosing dialysis instead of conservative care. Methods: We conducted a discrete choice experiment involving adults with stage 3–5 chronic kidney disease from eight renal clinics in Australia. We assessed the influence of treatment characteristics (life expectancy, number of visits to the hospital per week, ability to travel, time spent undergoing dialysis [i.e., time spent attached to a dialysis machine per treatment, measured in hours], time of day at which treatment occurred, availability of subsidized transport and flexibility of the treatment schedule) on patients’ preferences for dialysis versus conservative care. Results: Of 151 patients invited to participate, 105 completed our survey. Patients were more likely to choose dialysis than conservative care if dialysis involved an increased average life expectancy (odds ratio [OR] 1.84, 95% confidence interval [CI] 1.57–2.15), if they were able to dialyse during the day or evening rather than during the day only (OR 8.95, 95% CI 4.46–17.97), and if subsidized transport was available (OR 1.55, 95% CI 1.24–1.95). Patients were less likely to choose dialysis over conservative care if an increase in the number of visits to hospital was required (OR 0.70, 95% CI 0.56–0.88) and if there were more restrictions on their ability to travel (OR = 0.47, 95%CI 0.36–0.61). Patients were willing to forgo 7 months of life expectancy to reduce the number of required visits to hospital and 15 months of life expectancy to increase their ability to travel. Interpretation: Patients approaching end-stage kidney disease are willing to trade considerable life expectancy to reduce the burden and restrictions imposed by dialysis. PMID:22311947
Racial determination of origin of mourning doves in hunters' bags
Aldrich, J.W.; Duvall, A.J.; Geis, A.D.
1958-01-01
A method is described for determining the general area of production of mourning doves that are shot during the hunting season. This procedure is based on the identification of racial characteristics that can be ascertained from samples of wings. The application and utility of this method were demonstrated with data gathered from doves shot in two important dove-hunting areas, Georgia and Texas. The Georgia data indicated that the early-season kill consisted largely of the race carolinensis, while later in the season marginella and the intermediate form made up most of the bag. The wing samples from Texas indicated that birds produced outside of southern Texas made up the largest part of the bag in southern Texas during the entire season. Doves produced west of the Appalachians contributed to both the Georgia and Texas kill.
Oxalate quantification in hemodialysate to assess dialysis adequacy for primary hyperoxaluria
Tang, Xiaojing; Voskoboev, Nikolay V.; Wannarka, Stacie L.; Olson, Julie B.; Milliner, Dawn S.; Lieske, John C.
2015-01-01
Background Patients with primary hyperoxaluria (PH) overproduce oxalate which is eliminated via the kidneys. If end stage kidney disease develops they are at high risk for systemic oxalosis, unless adequate oxalate is removed during hemodialysis to equal or exceed ongoing oxalate production. The purpose of this study was to validate a method to measure oxalate removal in this unique group of dialysis patients. Methods Fourteen stable patients with a confirmed diagnosis of PH on hemodialysis were included in the study. Oxalate was measured serially in hemodialysate and plasma samples in order to calculate rates of oxalate removal. Hemodialysis regimens were adjusted according to a given patient's historical oxalate production, amount of oxalate removal at dialysis, residual renal clearance of oxalate, and plasma oxalate levels. Results After a typical session of hemodialysis, plasma oxalate was reduced by 78.4±7.7%. Eight patients performed hemodialysis 6 times a week, two patients 5 times a week and three patients 3 times a week. Combined oxalate removal by hemodialysis and the kidneys was sufficient to match or exceed endogenous oxalate production. After a median period of 9 months, pre-dialysis plasma oxalate was significantly lower than initially (75.1±33.4 mmol/L vs. 54.8±46.6 mmol/L, P=0.02). Conclusion This methodology can be used to individualize the dialysis prescription of PH patients to prevent oxalosis during the time they are maintained on hemodialysis, and to reduce risk of oxalate injury to a transplanted kidney. PMID:24776840
Sato, Takashi; Taoka, Masahiro; Miyahara, Takaaki
2011-01-01
In Japan, acetate-free biofiltration (AFBF) became commercially available in the year 2000, and these products have been reported to be clinically effective for controlling the decrease of blood pressure during dialysis or various types of dialysis intolerance. And more, acetate-free dialysis fluid was made clinically available in 2007, acetate-free hemodialysis (AFHD) is expected to inhibit the malnutrition-inflammation-atherosclerosis syndrome, improve anemia and the nutritional status of patients, stabilize hemodynamics, and reduce inflammation and oxidative stress. In a broad sense, AFBF can be classified as hemodiafiltration (HDF), and its clinical effects seem to be associated with multiple factors, including use of acetate-free dialysis fluid, massive removal of low molecular weight proteins by convection, and the sodium concentration of the replacement fluid. Therefore, the clinical significance of acetate-free dialysis fluid could be demonstrated more clearly by comparing AFHD with conventional hemodialysis (conv. HD) using dialysis fluid containing about 10 mEq/l acetate. Since 2005, we have been investigating the efficacy of various modalities of blood purification therapy by continuously monitoring changes of tissue blood flow in the lower limbs and earlobes (head) using non-invasive continuous monitoring method (NICOMM). In this report, we assess the clinical effectiveness of AFHD on the basis of clinical findings and head stability index (head SI) obtained by NICOMM, particularly with respect to the influence on autonomic regulation. After switching to AFHD from conv. HD, anemia, stored iron utilization, and the frequency of treatments for dialysis hypotension and of muscle cramps were significantly improved. Further, the head SI was also significantly smaller with AFHD than conv. HD. This finding suggests that AFHD improved the maintenance of homeostasis by the autonomic nervous regulation system. In addition, we could not find clinical features of excessive alkalosis during an observation period of about 1 year, even if online HDF using acetate-free dialysis fluid as the substitution fluid. Our conclusion is that the advent of acetate-free dialysis fluid has led to investigations into new clinical effectiveness of AFHD or online HDF/HF using ultrapurified acetate-free dialysis fluid as the substitution fluid. Copyright © 2011 S. Karger AG, Basel.
Bactericidal effects of bioactive glasses on clinically important aerobic bacteria.
Munukka, Eveliina; Leppäranta, Outi; Korkeamäki, Mika; Vaahtio, Minna; Peltola, Timo; Zhang, Di; Hupa, Leena; Ylänen, Heimo; Salonen, Jukka I; Viljanen, Matti K; Eerola, Erkki
2008-01-01
Bioactive glasses (BAGs) have been studied for decades for clinical use, and they have found many dental and orthopedic applications. BAGs have also been shown to have an antibacterial effect e.g., on some oral microorganisms. In this extensive work we show that six powdered BAGs and two sol-gel derived materials have a clear antibacterial effect on 29 clinically important bacterial species. We also incorporated a rapid and accurate flow cytometric (FCM) method to calculate and standardize the numbers of viable bacteria inoculated in the suspensions used in the tests for antibacterial activity. In all materials tested growth inhibition could be demonstrated, although the concentration and time needed for the effect varied depending on the BAG. The most effective glass was S53P4, which had a clear growth-inhibitory effect on all pathogens tested. The sol-gel derived materials CaPSiO and CaPSiO II also showed a strong antibacterial effect. In summary, BAGs were found to clearly inhibit the growth of a wide selection of bacterial species causing e.g., infections on the surfaces of prostheses in the body after implantation.
Winfield, Jonathan; Chambers, Lily D; Rossiter, Jonathan; Ieropoulos, Ioannis
2013-11-01
The long and short-term stability of two porous dependent ion exchange materials; starch-based compostable bags (BioBag) and ceramic, were compared to commercially available cation exchange membrane (CEM) in microbial fuel cells. Using bi-directional polarisation methods, CEM exhibited power overshoot during the forward sweep followed by significant power decline over the reverse sweep (38%). The porous membranes displayed no power overshoot with comparably smaller drops in power during the reverse sweep (ceramic 8%, BioBag 5.5%). The total internal resistance at maximum power increased by 64% for CEM compared to 4% (ceramic) and 6% (BioBag). Under fixed external resistive loads, CEM exhibited steeper pH reductions than the porous membranes. Despite its limited lifetime, the BioBag proved an efficient material for a stable microbial environment until failing after 8 months, due to natural degradation. These findings highlight porous separators as ideal candidates for advancing MFC technology in terms of cost and operation stability. Copyright © 2013 Elsevier Ltd. All rights reserved.
Developing Baby Bag Design by Using Kansei Engineering Method
NASA Astrophysics Data System (ADS)
Janari, D.; Rakhmawati, A.
2016-01-01
Consumer's preferences and market demand are essential factors for product's success. Thus, in achieving its success, a product should have design that could fulfill consumer's expectation. Purpose of this research is accomplishing baby bag product as stipulated by Kansei. The results that represent Kanseiwords are; neat, unique, comfortable, safe, modern, gentle, elegant, antique, attractive, simple, spacious, creative, colorful, durable, stylish, smooth and strong. Identification value on significance of correlation for durable attribute is 0,000 < 0,005, which means significant to baby's bag. While the value of coefficient regression is 0,812 < 0,005, which means that durable attribute insignificant to baby's bag.The result of the baby's bag final design selectionbased on the questionnaire 3 is resulting the combination of all design. Space for clothes, diaper's space, shoulder grip, side grip, bottle's heater pocket and bottle's pocket are derived from design 1. Top grip, space for clothes, shoulder grip, and side grip are derived from design 2.Others design that were taken are, spaces for clothes from design 3, diaper's space and clothes’ space from design 4.
Handling imbalance data in churn prediction using combined SMOTE and RUS with bagging method
NASA Astrophysics Data System (ADS)
Pura Hartati, Eka; Adiwijaya; Arif Bijaksana, Moch
2018-03-01
Customer churn has become a significant problem and also a challenge for Telecommunication company such as PT. Telkom Indonesia. It is necessary to evaluate whether the big problems of churn customer and the company’s managements will make appropriate strategies to minimize the churn and retaining the customer. Churn Customer data which categorized churn Atas Permintaan Sendiri (APS) in this Company is an imbalance data, and this issue is one of the challenging tasks in machine learning. This study will investigate how is handling class imbalance in churn prediction using combined Synthetic Minority Over-Sampling (SMOTE) and Random Under-Sampling (RUS) with Bagging method for a better churn prediction performance’s result. The dataset that used is Broadband Internet data which is collected from Telkom Regional 6 Kalimantan. The research firstly using data preprocessing to balance the imbalanced dataset and also to select features by sampling technique SMOTE and RUS, and then building churn prediction model using Bagging methods and C4.5.
Yu, Hualong; Ni, Jun
2014-01-01
Training classifiers on skewed data can be technically challenging tasks, especially if the data is high-dimensional simultaneously, the tasks can become more difficult. In biomedicine field, skewed data type often appears. In this study, we try to deal with this problem by combining asymmetric bagging ensemble classifier (asBagging) that has been presented in previous work and an improved random subspace (RS) generation strategy that is called feature subspace (FSS). Specifically, FSS is a novel method to promote the balance level between accuracy and diversity of base classifiers in asBagging. In view of the strong generalization capability of support vector machine (SVM), we adopt it to be base classifier. Extensive experiments on four benchmark biomedicine data sets indicate that the proposed ensemble learning method outperforms many baseline approaches in terms of Accuracy, F-measure, G-mean and AUC evaluation criterions, thus it can be regarded as an effective and efficient tool to deal with high-dimensional and imbalanced biomedical data.
Press, Christopher; Duffy, Christopher; Williams, Jonathan; Cooper, Ben; Chapman, Neil
2017-01-01
Accidental hypothermia is common in those who sustain injuries in remote environments. This is unpleasant and associated with adverse effects on subsequent patient outcomes. To minimise further heat loss, a range of insulating systems are available to mountain rescue teams although the most effective and cost-efficient have yet to be determined. Under ambient, still, dry, air conditions, a thermal manikin was filled with water at a temperature of 42 °C and then placed into a given insulation system. Water temperature was then continuously observed via an in-dwelling temperature sensor linked to a PROPAQ 100 series monitor and recorded every 10 min for 130 min. This method was repeated for each insulating package. The vacuum mattress/Pertex©/fibrepile blanket system, either on its own or coupled with the Wiggy bag, was the most efficient with water temperatures only decreasing by 3.2 °C over 130 min. This was followed by the heavy-weight casualty bags without the vacuum mattress/Pertex©/fibrepile blanket system, decreasing by 4.2-4.3 °C. With the Blizzard bag, a decline in water temperature of 5.4 °C was seen over the study duration while a decrease of 9.5 °C was noted when the plastic survival bag was employed. Under the still-air conditions of the study, the vacuum mattress/Pertex©/fibrepile blanket was seen to offer comparable insulation effectiveness compared to be both heavy-weight casualty bags. In turn, these three systems appeared more efficient at insulating the manikin than the Blizzard bag or plastic survival bag.
Biofilm formation affects surface properties of novel bioactive glass-containing composites.
Hyun, Hong-Keun; Salehi, Satin; Ferracane, Jack L
2015-12-01
This study investigated the effects of bacterial biofilm on the surface properties of novel bioactive glass (BAG)-containing composites of different initial surface roughness. BAG (65 mol% Si; 4% P; 31% Ca) and BAG-F (61% Si; 31% Ca; 4% P; 3% F; 1% B) were synthesized by the sol-gel method and micronized (size ∼0.1-10 μm). Composites with 72wt% total filler load were prepared by replacing 15% of the silanized Sr glass with BAG, BAG-F, or silanized silica. Specimens (n=10/group) were light-cured and divided into 4 subgroups of different surface roughness by wet polishing with 600 and then up to 1200, 2400, or 4000 grit SiC. Surface roughness (SR), gloss, and Knoop microhardness were measured before and after incubating in media with or without a Streptococcus mutans (UA 159) biofilm for 2 weeks. Results were analyzed with ANOVA/Tukey's test (α=0.05). The SR of the BAG-containing composites with the smoothest surfaces (2400/4000 grit) increased in media or bacteria; the SR of the roughest composites (600 grit) decreased. The gloss of the smoothest BAG-containing composites decreased in bacteria and media-only, but more in media-alone. The microhardness of all of the composites decreased with exposure to media or bacteria, with BAG-containing composites affected more than the control. Exposure to bacterial biofilm and its media produced enhanced roughness and reduced gloss and surface microhardness of highly polished dental composites containing a bioactive glass additive, which could affect further biofilm formation, as well as the esthetics, of restorations made from such a material. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Parathyroid Hormone and Bone in Dialysis Patients.
Kazama, Junichiro James; Wakasugi, Minako
2018-06-01
Bone maintains extracellular calcium levels through a system called bone remodeling. Parathyroid hormone (PTH) is the major initiator of this system, which is secreted by the information through calcium sensing receptor in parathyroid cells. PTH modifies calcified bone morphology through a process of its bone action. Therefore, extremely hyperactivated parathyroid function seen in patients with chronic kidney disease has been considered to have a negative impact on the bone mechanical properties. While skeletal deformities and fragility fractures were common among dialysis patients up to the 1970s, after which methods for the treatment of hyperparathyroidism were developed, we now seldom encounter those cases with severe secondary hyperparathyroidism in Japan. In a three-dimensional morphometry of biopsied iliac bone samples obtained from dialysis patients, PTH level was inversely correlated with cortical bone thickness, however, this relationship disappeared among those with intact PTH < 1000 pg/mL. Higher PTH levels were associated with more complicated and irregular cancellous bone surface, but this change was not accompanied with decreased cancellous bone connectivity. These findings theoretically support the recent clinical study results that PTH levels no longer show a tight correlation with fracture risk in dialysis patients. Nevertheless, the use of calcium sensing receptor agonist is likely to be associated with reduced hip fracture risk in dialysis patients. Further study is needed to reveal its pharmacological mechanism on bone. © 2018 The Authors. Therapeutic Apheresis and Dialysis published by John Wiley & Sons Australia, Ltd on behalf of International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.
Moreta, Cristina; Tena, María Teresa
2014-08-15
An analytical method is proposed to determine ten perfluorinated alkyl acids (PFAAs) [nine perfluorocarboxylic acids (PFCAs) and perfluorooctane sulfonate (PFOS)] in corn, popcorn and microwave popcorn packaging by focused ultrasound solid-liquid extraction (FUSLE) and ultra high performance liquid chromatography (UHPLC) coupled to quadrupole-time of flight mass spectrometry (QTOF-MS/MS). Selected PFAAs were extracted efficiently in only one 10-s cycle by FUSLE, a simple, safe and inexpensive technique. The developed method was validated for microwave popcorn bags matrix as well as corn and popcorn matrices in terms of linearity, matrix effect error, detection and quantification limits, repeatability and recovery values. The method showed good accuracy with recovery values around 100% except for the lowest chain length PFAAs, satisfactory reproducibility with RSDs under 16%, and sensitivity with limits of detection in the order of hundreds picograms per gram of sample (between 0.2 and 0.7ng/g). This method was also applied to the analysis of six microwave popcorn bags and the popcorn inside before and after cooking. PFCAs contents between 3.50ng/g and 750ng/g were found in bags, being PFHxA (perfluorohexanoic acid) the most abundant of them. However, no PFAAs were detected either corn or popcorn, therefore no migration was assumed. Copyright © 2014 Elsevier B.V. All rights reserved.
[Analysis of phthalates in plastic food-packaging bags by thin layer chromatography].
Chen, Hui; Wang, Yuan; Zhu, Ruohua
2006-01-01
The method for simultaneous determination of four phthalates, namely dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP) and di (2-ethylhexyl) phthalate (DEHP) in plastic food-packaging bags by thin layer chromatography (TLC) was developed. The plastic food-packaging bags were extracted with ethanol by ultrasonication, then the mixture was filtrated through membrane (0.45 microm). The mixture of ethyl acetate-anhydrous ether-isooctane (1 : 4 : 15, v/v) was used as developing agent on the TLC silica gel plate for development. The filtered liquid was spotted on the TLC plate dealt by acetone, and detected with scanning wavelength of 275 nm and reference wavelength of 340 nm. The qualitative analysis of the phthalates was performed using the R(f) values of the chromatogram. The quantitative analysis was performed with external standard method. Good linearities were obtained for DMP, DEP, DBP and DEHP. The detection limits were 2.1 ng for DMP, 2.4 ng for DEP, 3.4 ng for DBP and 4.0 ng for DEHP. The relative standard deviations (RSDs) of the four phthalates were 2.8% - 3.5%. The recoveries of the four phthalate standards in real sample were 78.58% - 111.04%. The method presented has the advantages of high precision, high sensitivity, small sample size, and simple pretreatment . The method was used to detect the four phthalates in the food-packaging bags. The contents in real samples were close to the results by gas chromatography.
Randomised clinical trial of chest drainage systems.
Graham, A N; Cosgrove, A P; Gibbons, J R; McGuigan, J A
1992-01-01
BACKGROUND: Problems in the management of thoracic trauma have stimulated the search for an alternative to underwater seals for drainage of the pleural cavity. A chest drainage bag incorporating a one way flutter valve has been compared with underwater seal drains in a randomised clinical trial. METHODS: During June-December 1989 119 patients undergoing elective thoracotomy were randomised to receive postoperative chest drainage by drainage bags (56 patients, 87 drains) or by underwater seal drains (63 patients, 98 drains). Daily drainage volumes, the requirement for pleural suction, mobility, and complications were recorded prospectively. RESULTS: There was no significant difference between the two groups in the mean volume drained, the requirements for pleural suction, or the occurrence of complications. Patients with drainage bags were fully mobile 23 hours (95% confidence interval 0-47 hours) earlier than the others. CONCLUSIONS: When used after elective thoracotomy drainage bags are safe and effective and permit earlier mobility than underwater seal drains. PMID:1496507
Method for vacuum pressing electrochemical cell components
NASA Technical Reports Server (NTRS)
Andrews, Craig C. (Inventor); Murphy, Oliver J. (Inventor)
2004-01-01
Assembling electrochemical cell components using a bonding agent comprising aligning components of the electrochemical cell, applying a bonding agent between the components to bond the components together, placing the components within a container that is essentially a pliable bag, and drawing a vacuum within the bag, wherein the bag conforms to the shape of the components from the pressure outside the bag, thereby holding the components securely in place. The vacuum is passively maintained until the adhesive has cured and the components are securely bonded. The bonding agent used to bond the components of the electrochemical cell may be distributed to the bonding surface from distribution channels in the components. To prevent contamination with bonding agent, some areas may be treated to produce regions of preferred adhesive distribution and protected regions. Treatments may include polishing, etching, coating and providing protective grooves between the bonding surfaces and the protected regions.
USDA-ARS?s Scientific Manuscript database
Cooking or reheating food in a vacuum sealed bag has been a common method of preparing vegetables, meat and poultry products. There are very few examples of vacuum sealed bags designed for cooking or reheating catfish fillets. The objective of the present study was to examine the properties of raw f...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-26
... excludes (1) polyethylene bags that are not printed with logos or store names and that are closeable with... comparison methodology to TCI's targeted sales and the average-to-average comparison methodology to TCI's non... average-to-average comparison method does not account for such price differences and results in the...
ERIC Educational Resources Information Center
Sweitzer, Sara J.; Briley, Margaret E.; Roberts-Gray, Cindy; Hoelscher, Deanna M.; Harrist, Ronald B.; Staskel, Deanna M.; Almansour, Fawaz D.
2011-01-01
Objective: This pilot study evaluated effects of "Lunch is in the Bag" on behavioral constructs and their predictive relationship to lunch-packing behaviors of parents of young children. Methods: Six child care centers were pair-matched and randomly assigned to intervention (n = 3) and comparison (n = 3) groups. Parent/child dyads participated.…
2011-01-01
Background Haemodialysis is the most common form of renal replacement therapy in Nigeria. The high cost of haemodialysis has made optimal therapy of end-stage renal disease difficult in Nigeria. This paper is a review of data collected over two years of provision of dialysis services in a new tertiary hospital in Southern Nigeria. Methods This retrospective analysis is done on data obtained from the patient case files and dialysis records in the first two years of provision of dialysis services in our centre. A gender comparison of the patients' baseline sociodemographic, clinical and biochemical was performed and a logistic regression model used to assess the predictors of mortality. Results A total of 98 patients had 471 sessions in the two years under review. Males and females had similar characteristics at baseline except for a higher median serum urea in the males. The commonest causes of end-stage renal disease were chronic glomerulonephritis (34.5%), hypertension (32.1%) and diabetes mellitus (17.9%). The main predictor of mortality was under treatment with haemodialysis due to inability to pay for more than a few dialysis sessions. Conclusions This study has highlighted the unchanging demographics of our advanced kidney failure patients. Efforts should be aimed at subsidizing the cost of dialysis for our teeming population of dialysis dependent chronic kidney disease patients. PMID:21962220
Kreuzer, Martin; Gähler, Dagmar; Rakenius, Annette C; Prüfe, Jenny; Jack, Thomas; Pfister, Eva-Doreen; Pape, Lars
2015-12-01
Acute kidney injury (AKI) is a major complication in children with hepatic failure which leads to increased morbidity and mortality. The aim of this study was to provide paediatric data on the prevalence of dialysis-dependent AKI (dAKI), the feasibility and efficacy of dialysis methods and outcome. We conducted a retrospective analysis of 367 children listed for orthotopic liver transplantation (OLT) in our centre during the past decade. Data on 30 children (15 boys, 15 girls) were compiled for retrospective analysis, and data on dialysis feasibility and efficacy were available for 26 of these. Median age was 3.5 (range 0.4-17.7) years. Median MELD (Model For End-Stage Liver Disease) score was 33. dAKI was caused by hepato-renal syndrome in 16 of the 30 children. Twenty-one patients were treated with continuous veno-venous haemofiltration (CVVH), and nine patients received peritoneal dialysis (PD). Overall mortality was 77%. Mortality within the PD-group was 100 % versus 67% in the CVVH-group (p = 0.039). Urea reduction rate within the first 24 h of treatment was 12.9% in the PD group and 23.5% in the CVVH group (p = 0.019). Children with end-stage liver disease have a high risk for dAKI associated with high mortality. CVVH is associated with better efficacy and less mortality than PD.
Vinsonneau, Christophe; Allain-Launay, Emma; Blayau, Clarisse; Darmon, Michael; Ducheyron, Damien; Gaillot, Theophile; Honore, Patrick M; Javouhey, Etienne; Krummel, Thierry; Lahoche, Annie; Letacon, Serge; Legrand, Matthieu; Monchi, Mehran; Ridel, Christophe; Robert, René; Schortgen, Frederique; Souweine, Bertrand; Vaillant, Patrick; Velly, Lionel; Osman, David; Van Vong, Ly
2015-12-01
Acute renal failure (ARF) in critically ill patients is currently very frequent and requires renal replacement therapy (RRT) in many patients. During the last 15 years, several studies have considered important issues regarding the use of RRT in ARF, like the time to initiate the therapy, the dialysis dose, the types of catheter, the choice of technique, and anticoagulation. However, despite an abundant literature, conflicting results do not provide evidence on RRT implementation. We present herein recommendations for the use of RRT in adult and pediatric intensive care developed with the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) system by an expert group of French Intensive Care Society (SRLF), with the participation of the French Society of Anesthesia and Intensive Care (SFAR), the French Group for Pediatric Intensive Care and Emergencies (GFRUP), and the French Dialysis Society (SFD). The recommendations cover 4 fields: criteria for RRT initiation, technical aspects (access routes, membranes, anticoagulation, reverse osmosis water), practical aspects (choice of the method, peritoneal dialysis, dialysis dose, adjustments), and safety (procedures and training, dialysis catheter management, extracorporeal circuit set-up). These recommendations have been designed on a practical point of view to provide guidance for intensivists in their daily practice.
Collell, Guillem; Prelec, Drazen; Patil, Kaustubh R
2018-01-31
Class imbalance presents a major hurdle in the application of classification methods. A commonly taken approach is to learn ensembles of classifiers using rebalanced data. Examples include bootstrap averaging (bagging) combined with either undersampling or oversampling of the minority class examples. However, rebalancing methods entail asymmetric changes to the examples of different classes, which in turn can introduce their own biases. Furthermore, these methods often require specifying the performance measure of interest a priori, i.e., before learning. An alternative is to employ the threshold moving technique, which applies a threshold to the continuous output of a model, offering the possibility to adapt to a performance measure a posteriori , i.e., a plug-in method. Surprisingly, little attention has been paid to this combination of a bagging ensemble and threshold-moving. In this paper, we study this combination and demonstrate its competitiveness. Contrary to the other resampling methods, we preserve the natural class distribution of the data resulting in well-calibrated posterior probabilities. Additionally, we extend the proposed method to handle multiclass data. We validated our method on binary and multiclass benchmark data sets by using both, decision trees and neural networks as base classifiers. We perform analyses that provide insights into the proposed method.
van der Borg, Wieke E; Schipper, Karen; Abma, Tineke A
2016-07-08
Patients with end-stage renal disease (ESRD) commonly suffer from severe fatigue, which strongly impacts their quality of life (QoL). Although fatigue is often attributed to disease- and treatment characteristics, research also shows that behavioural, psychological and social factors affect perceived fatigue in dialysis patients. Whereas studies on fatigue in other chronic patient groups suggest that psychological or psychosocial interventions are effective in reducing fatigue, such interventions are not yet available for ESRD patients on dialysis treatment. The objective of this study is to examine the efficacy of a psychosocial intervention for dialysis patients aimed at reducing fatigue (primary outcome) and improving QoL (secondary outcome). The intervention consists of counselling sessions led by a social worker. The implementation process and patients' and social workers' expectations and experiences with the intervention will also be evaluated. This study follows a mixed-methods design in which both quantitative and qualitative data will be collected. A multi-centre, randomised controlled trial (RCT) with repeated measures will be conducted to quantitatively assess the efficacy of the psychosocial intervention in reducing fatigue and improving QoL in ESRD patients. Additional secondary outcomes and medical parameters will be assessed. Outcomes will be compared to patients receiving usual care. A sample of 74 severely fatigued dialysis patients will be recruited from 10 dialysis centres. Patients will be randomly assigned to the intervention or control group. Outcomes will be assessed at baseline, post intervention/16 weeks, and at three and six-month follow-ups. A qualitative process evaluation will be conducted parallel to/following the effectiveness RCT. Interviews and focus groups will be conducted to gain insight into patients' and social workers' perspectives on outcomes and implementation procedures. Implementation fidelity will be assessed by audio-taped and written registrations. Participatory methods ensure the continuous input of experiential knowledge, improving the quality of study procedures and the applicability of outcomes. This is the first mixed method study (including an RCT and qualitative process evaluation) to examine the effect and implementation process of a psychosocial intervention on reducing fatigue and improving QoL in ESRD patients on dialysis treatment. NTR5366 , The Netherlands National Trial Register (NTR), registered August 26, 2015.
Sayarlioglu, Hayriye; Topal, Cevat; Sayarlioglu, Mehmet; Dulger, Haluk; Dogan, Ekrem; Erkoc, Reha
2004-01-01
OBJECTIVE: It is known that glucose concentrations of peritoneal dialysis solutions are detrimental to the peritoneal membrane. In order to determine the effect of glucose concentration on cytokine levels of peritoneal fluid of continuous ambulatory peritoneal dialysis (CAPD) patients, a cross-sectional study was performed. METHODS: Nine non-diabetic CAPD patients participated in two 8-h dwell sessions of overnight exchanges in consecutive days, with 1.36% and 3.86% glucose containing peritoneal dialysis solutions (Baxter-Eczacibas). Peritoneal dialysis fluid tumor necrosis factor (TNF)-alpha and interleukin (IL)-6 levels were measured. RESULTS: TNF-alpha levels after 1.36% and 3.86% glucose used dwells were 23+/-14 pg/ml and 28+/-4 pg/ml, respectively (p=0.78). The IL-6 levels were 106+/-57 pg/ml and 115+/-63 pg/ml (p=0.81), respectively. CONCLUSION: In our in vivo study we found that the glucose concentration of the conventional lactate-based CAPD solution has no effect on basal IL-6 and TNF-alpha levels of peritoneal fluid. Further in vivo studies with non-lactate-based CAPD solutions are needed in order to determine the effect of glucose concentration per se on cytokine release. PMID:15203553
Soft tissue decomposition of submerged, dismembered pig limbs enclosed in plastic bags.
Pakosh, Caitlin M; Rogers, Tracy L
2009-11-01
This study examines underwater soft tissue decomposition of dismembered pig limbs deposited in polyethylene plastic bags. The research evaluates the level of influence that disposal method has on underwater decomposition processes and details observations specific to this scenario. To our knowledge, no other study has yet investigated decomposing, dismembered, and enclosed remains in water environments. The total sample size consisted of 120 dismembered pig limbs, divided into a subsample of 30 pig limbs per recovery period (34 and 71 days) for each treatment. The two treatments simulated non-enclosed and plastic enclosed disposal methods in a water context. The remains were completely submerged in Lake Ontario for 34 and 71 days. In both recovery periods, the non-enclosed samples lost soft tissue to a significantly greater extent than their plastic enclosed counterparts. Disposal of remains in plastic bags therefore results in preservation, most likely caused by bacterial inhibition and reduced oxygen levels.
Performance tests of three types of air-sampling bags on organic solvent vapor retention.
Fukui, Yoshinari; Kanemaru, Ai; Nagasawa, Yasuhiro; Kawakami, Takuya; Iwata, Toyoto; Murata, Katsuyuki; Ohashi, Fumiko; Ikeda, Masayuki
2013-01-01
Performance of two new air sampling bags [the transparent bag (TP bag) and the semi-transparent bag (ST bag)] was examined as possible surrogates for the traditional PVF bag (the Ref bag). Solvent vapor mixture of butyl acetate, chloroform, ethyl acetate, isopropyl alcohol and toluene at administrative control levels were introduced to each bag (n=5 for each of the three types), and the decay in the concentrations (by%) was followed by use of a gas auto-sampler - FID-GC system. A trend of time-dependent decay was noted for all types including the Ref bag. When the performance was compared, the TP bag was equal to or even better than the Ref bag. In contrast, the performance of the ST bag was comparable to that of the other two types of bags with regard to toluene and chloroform when the storage time was short, but poorer than others for the other three solvents throughout the test period. The TP bag may be a bag of choice when the storage time is extended (e.g., up to 48 h) although this bag is physically less robust and requires careful handling. The ST bag may be used when analysis will be completed within 24 h.
Pagella, J H; Mayes, R W; Pérez-Barbería, F J; Ørskov, E R
2018-01-01
Although the conventional in situ ruminal degradability method is a relevant tool to describe the nutritional value of ruminant feeds, its need for rumen-fistulated animals may impose a restriction on its use when considering animal welfare issues and cost. The aim of the present work was to develop a ruminal degradability technique which avoids using surgically prepared animals. The concept was to orally dose a series of porous bags containing the test feeds at different times before slaughter, when the bags would be removed from the rumen for degradation measurement. Bags, smaller than those used in the conventional nylon bag technique, were made from woven nylon fabric, following two shape designs (rectangular flat shape, tetrahedral shape) and were fitted with one of three types of device for preventing their regurgitation. These bags were used in two experiments with individually housed non-pregnant, non-lactating sheep, as host animals for the in situ ruminal incubation of forage substrates. The bags were closed at the top edge by machine stitching and wrapped in tissue paper before oral dosing. Standard times for ruminal incubation of substrates in all of the tests were 4, 8, 16, 24, 48, 72 and 96 h before slaughter. The purpose of the first experiment was to compare the effectiveness of the three anti-regurgitation device designs, constructed from nylon cable ties ('Z-shaped', ARD1; 'double Z-shaped', ARD2; 'umbrella-shaped', ARD3), and to observe whether viable degradation curves could be generated using grass hay as the substrate. In the second experiment, three other substrates (perennial ryegrass, red clover and barley straw) were compared using flat and tetrahedral bags fitted with type ARD1 anti-regurgitation devices. Non-linear mixed-effect regression models were used to fit asymptotic exponential curves of the percentage dry matter loss of the four substrates against time of incubation in the reticulorumen, and the effect of type of anti-regurgitation device and the shape of nylon bag. All three devices were highly successful at preventing regurgitation with 93% to 100% of dosed bags being recovered in the reticulorumen at slaughter. Ruminal degradation data obtained for tested forages were in accordance with those expected from the conventional degradability technique using fistulated animals, with no significant differences in the asymptotic values of degradation curves between bag shape or anti-regurgitation device. The results of this research demonstrate the potential for using a small bag technique with intact sheep to characterise the in situ ruminal degradability of roughages.
Nikniaz, Zeinab; Mahdavi, Reza; Ghaemmaghami, Seyed Jamal; Lotfi Yagin, Neda; Nikniaz, Leila
2016-01-01
Determination and comparison of the effect of infusion time on the antioxidant activity and total polyphenol contents of bagged and loosely packed black teas. For twenty loosely packed and eleven bagged tea samples, the antioxidant activity and total polyphenol content were analyzed using FRAP and Folin-Ciocalteau methods, respectively. The ANOVA with Tukey post-hoc test and independent t-test were used for statistical analysis. The antioxidant activity and polyphenol content of various brands of tea samples were significantly different. There were significant differences in the antioxidant activity of loosely packed teas between 5, 15(p=0.03), 30(p=0.02) and 60(p=0.007) minutes of brewing times. Besides, there was a significant difference in antioxidant activity of bagged samples infused for 1 minute with four other infusion time points (p<0.001). In the case of polyphenol content, in loosely-packed tea samples, there were not significant differences between different brewing times (p=0.15). However, in bagged samples, the polyphenol contents of samples that were brewed for 1 minute were significantly lower than samples brewed for 3, 4, and 5 minutes (p<0.05). The antioxidant activity and polyphenol content of tea bags were significantly higher than those ofloosely-packed forms of the same brands at 5-min of brewing time (p<0.001). The infusion time and the form of tea (loosely packed or bagged) were shown to be important determinants of the antioxidant activity and polyphenol content of black tea infusions in addition to the variety, growing environment and manufacturing conditions.
Practicability of Hygienic Wrapping of Touchscreen Operated Mobile Devices in a Clinical Setting
Hammon, Matthias; Kunz, Bernd; Dinzl, Veronika; Kammerer, Ferdinand J.; Schwab, Siegfried A.; Bogdan, Christian; Uder, Michael; Schlechtweg, Philipp M.
2014-01-01
Background To prove effectiveness of wrapping tablet computers in order to reduce microbiological contamination and to evaluate whether a plastic bag-covered tablet leads to impaired user satisfaction or touchscreen functionality. Materials and Methods Within a period of 11 days 115 patients were provided with a tablet computer while waiting for their magnetic resonance imaging examination. Every day the contamination of the surface of the tablet was determined before the first and after the final use. Before the device was handed over to a patient, it was enclosed in a customized single-use plastic bag, which was analyzed for bacterial contamination after each use. A questionnaire was applied to determine whether the plastic bag impairs the user satisfaction and the functionality of the touchscreen. Results Following the use by patients the outside of the plastic bags was found to be contaminated with various bacteria (657.5 ± 368.5 colony forming units/day); some of them were potentially pathogenic. In contrast, the plastic bag covered surface of the tablet was significantly less contaminated (1.7 ± 1.9 colony forming units/day). Likewise, unused plastic bags did not show any contamination. 11% of the patients reported problems with the functionality of the touchscreen. These patients admitted that they had never used a tablet or a smartphone before. Conclusions Tablets get severely contaminated during usage in a clinical setting. Wrapping with a customized single-use plastic bag significantly reduces microbiological contamination of the device, protects patients from the acquisition of potentially pathogenic bacteria and hardly impairs the user satisfaction and the functionality of the touchscreen. PMID:25180580
Yang, Chang; Bai, Jie; Du, Shou-Ying; Cui, Ya-Hua; Zhang, Qin-Shuai; Ma, Jun-Ming
2016-11-01
To establish a method for detecting micro-dialysis recovery of paeonol, eugenol and piperine in Huoxue Zhitong patch, in order to provide the basis for further percutaneous pharmacokinetics studies. The concentrations of paeonol, eugenol and piperine in dialysates were determined by HPLC, and probe deliveries were calculated respectively. The effects of concentration and calibration approaches on the micro-dialysis probe deliveries of the three components were investigated, and their probe absorbability, in vitro and in vivo probe stability and repeatability were also studied.The results indicated that little paeonol, eugenol and piperine were observed in probes with 30% alcohol as the perfusate, and could be cleaned from probe in a short time. And the in vivo and in vitro probe deliveries of three components were stable within 8 h, drug-containing solution and blank perfusate were alternatively used for three times, and the in vivo and in vitro probe deliveries of three components were basically unchanged. The in vitro recoveries of paeonol, eugenol and piperine with a range of concentration were respectively (45.7±4.66)%, (27.82±2.95)%, (41.3±3.96)%, which indicated no concentration independent. Under the same conditions, the similar delivery was observed by dialysis, retrodialysis and no-net flux. Therefore, the concentrations of analyses of the collected fraction could be calibrated by in vitro or in vivo recoveries. Meanwhile, this also proved that the micro-dialysis method built by this study is applicable to the study on percutaneous pharmacokinetics of Huoxue Zhitong patch. Copyright© by the Chinese Pharmaceutical Association.
The future of the artificial kidney: moving towards wearable and miniaturized devices.
Ronco, C; Davenport, A; Gura, V
2011-01-01
New directions in dialysis research include cheaper treatments, home based therapies and simpler methods of blood purification. These objectives may be probably obtained with innovations in the field of artificial kidney through the utilization of new disciplines such as miniaturization, microfluidics, nanotechnology. This research may lead to a new era of dialysis in which the new challenges are transportability, wearability and why not the possibility to develop implantable devices. Although we are not there yet, a new series of papers have recently been published disclosing interesting and promising results on the application of wearable ultrafiltration systems (WUF) and wearable artificial kidneys (WAK). Some of them use extracorporeal blood cleansing as a method of blood purification while others use peritoneal dialysis as a treatment modality (ViWAK and AWAK.) A special mention deserves the wearable/portable ultrafiltration system for the therapy of overhydration and congestive heart failure (WAKMAN). This system will allow dehospitalization and treatment of patients with less comorbidity and improved tolerance. On the way to the wearable artificial kidney, new discoveries have been made such as a complete system for hemofiltration in newborns (CARPEDIEM). The neonate in fact is the typical patient who may benefit from miniaturization of the dialysis circuit. This review analyzes the rationale for such endeavour and the challenges to overcome in order to make possible a true ambulatory dialysis treatment. Some initial results with these new devices are presented. We would like to stimulate a collaborative effort to make a quantum leap in technology making the wearable artificial kidney a reality rather than a dream.
The storage stability of biogenic volatile organic compounds (BVOCs) in polyester aluminum bags
NASA Astrophysics Data System (ADS)
Ahn, Jeong-Hyeon; Deep, Akash; Kim, Ki-Hyun
2016-09-01
In this study, the sorptive loss properties of biogenic volatile organic compounds (BVOCs) in polyester aluminum bags were investigated as a function of storage duration. To this end, the relative recovery of gas phase standards of BVOCs, obtained via vaporization of liquid phase standards, was computed by calibrating their standards (response factors: RF) represnting each phase. Accordingly, the results indicated either slight loss (-5.59% (isoprene), -2.39% (camphene), -1.69% ((R)-(+)-limonene), -0.88% (p-cymene)) or gain (1.47% (γ-terpinene), 2.27% (α-terpinene), 2.63% (α-phellandrene), 2.73% ((+)-3-carene), 3.93% ((+)-β-pinene), and 5.98% ((+)-α-pinene)). Through comparison of the calibration results across storage time, the temporal stability of BVOCs was assessed. Longer BVOC storage time in polyester aluminum (PEA) bags lowered the relative recovery of BVOCs. The relative loss of BVOCs, if calculated in terms of mean bag standard RF ratios (relative to liquid standard) across elapsed time, decreased systematically: 0.99 ± 0.05 (0 h), 0.88 ± 0.06 (24 h), 0.66 ± 0.11 (72 h), and 0.62 ± 0.14 (120 h). It is thus recommended to complete the analysis of BVOC in PEA bags within 24 h of sample acquisition. As such, it is important to apply appropriate sampling approaches with a proper storage plan when measuring ambient BVOCs collected by bag sampling methods.
Non-Volatile Residue (NVR) Contamination from Dry Handling and Solvent Cleaning
NASA Technical Reports Server (NTRS)
Sovinski, Marjorie F.
2009-01-01
This slide presentation reviews the testing for Non-Volatile Residue contamination transferred to surfaces from handling and solvent cleaning. Included in the presentation is a list of the items tested, formal work instructions dealing with NVR. There is an explanation of the Gravimetric determination method used to test the NVR in a variety of items, i.e., Gloves, Swabs, Garments, Bagging material, film and Wipes. Another method to test for contamination from NVR is the contact transfer method. The use of this method for testing gloves, garments, bagging material and film is explained. Certain equations use in NVR analysis and the use of a database for testing of NVR in consumables are reviewed.
Hu, Kaili; Cao, Shan; Hu, Fuqiang; Feng, Jianfang
2012-01-01
The aim of this research work was to investigate the potential of lecithin nanoparticles (LNs) in improving the oral bioavailability of docetaxel. Docetaxel-loaded LNs (DTX-LNs) were prepared from oil-in-water emulsions and characterized in terms of morphology, size, zeta potential, and encapsulation efficiency. The in vitro release of docetaxel from the nanoparticles was studied by using dialysis bag method. Caco-2 cell monolayer was used for the in vitro permeation study of DTX-LNs. Bioavailability studies were conducted in rats and different pharmacokinetic parameters were evaluated after oral administration of DTX-LNs. The results showed that DTX-LNs had a mean diameter of 360 ± 8 nm and exhibited spherical shape with smooth surface under transmission electron microscopy. The DTX-LNs showed a sustained-release profile, with about 80% of docetaxel released within 72 hours. The apical to basolateral transport of docetaxel across the Caco-2 cell monolayer from the DTX-LNs was 2.14 times compared to that of the docetaxel solution (0.15 × 10−5 ± 0.016 × 10−5 cm/second versus 0.07 × 10−5 ± 0.003 × 10−5 cm/second). The oral bioavailability of the DTX-LNs was 3.65 times that of docetaxel solution (8.75% versus 2.40%). These results indicate that DTX-LNs were valuable as an oral drug delivery system to enhance the absorption of docetaxel. PMID:22848177
Terawaki, Hiroyuki; Nakayama, Masaaki; Seto, Kazuhiko; Yoshimura, Kazunobu; Hasegawa, Toshio
2004-08-01
We have established a new method of measuring translymphatic fluid absorption (TLA) using technetium-99m ((99m)Tc) human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) that can be used commonly in clinical practice. This new method was applied in 13 continuous ambulatory peritoneal dialysis patients (11 males and two females) who had various peritoneal permeability and capacities for peritoneal transport of water. (99m)Tc-HSAD 740MBq was injected in 2 L of peritoneal dialysis fluid with 2.5% glucose, mixed well, and administered intraperitoneally. The fluid was drained extraperitoneally after 4 h and TLA was determined by the in vivo loss of (99m)Tc-HSAD. TLA was 1.41 +/- 1.11 mL/min (mean +/- SD; range, 0.27-3.69 mL/min). The estimated reduction rate by TLA in trans-peritoneally removed fluid ranged from 14.2 to 84.4%, indicating that TLA could have an extremely significant negative effect in some cases on total drainage volume. The present study, using new tracer (99m)Tc-HSAD, could confirm a large individual difference in TLA, indicating TLA as an important contributing factor for fluid-removal failure in continuous ambulatory peritoneal dialysis patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, San San; Crabb, Simon J.; Janghra, Nari
2007-09-10
In oral cancers, cytoplasmic BAG-1 overexpression is a marker of poor prognosis. BAG-1 regulates cellular growth, differentiation and survival through interactions with diverse proteins, including the vitamin D receptor (VDR), a key regulator of keratinocyte growth and differentiation. BAG-1 is expressed ubiquitously in human cells as three major isoforms of 50 kDa (BAG-1L), 46 kDa (BAG-1M) and 36 kDa (BAG-1S) from a single mRNA. In oral keratinocytes BAG-1L, but not BAG-1M and BAG-1S, enhanced VDR transactivation in response to 1{alpha},25-dihydroxyvitamin D{sub 3.} BAG-1L was nucleoplasmic and nucleolar, whereas BAG-1S and BAG-1M were cytoplasmic and nucleoplasmic in localisation. Having identified themore » nucleolar localisation sequence in BAG-1L, we showed that mutation of this sequence did not prevent BAG-1L from potentiating VDR activity. BAG-1L also potentiated transactivation of known vitamin-D-responsive gene promoters, osteocalcin and 24-hydroxylase, and enhanced VDR-dependent transcription and protein expression of the keratinocyte differentiation marker, involucrin. These results demonstrate endogenous gene regulation by BAG-1L by potentiating nuclear hormone receptor function and suggest a role for BAG-1L in 24-hydroxylase regulation of vitamin D metabolism and the cellular response of oral keratinocytes to 1{alpha},25-dihydroxyvitamin D{sub 3}. By contrast to the cytoplasmic BAG-1 isoforms, BAG-1L may act to suppress tumorigenesis.« less
2012-01-01
Background Evidence is lacking to inform providers’ and patients’ decisions about many common treatment strategies for patients with end stage renal disease (ESRD). Methods/design The DEcIDE Patient Outcomes in ESRD Study is funded by the United States (US) Agency for Health Care Research and Quality to study the comparative effectiveness of: 1) antihypertensive therapies, 2) early versus later initiation of dialysis, and 3) intravenous iron therapies on clinical outcomes in patients with ESRD. Ongoing studies utilize four existing, nationally representative cohorts of patients with ESRD, including (1) the Choices for Healthy Outcomes in Caring for ESRD study (1041 incident dialysis patients recruited from October 1995 to June 1999 with complete outcome ascertainment through 2009), (2) the Dialysis Clinic Inc (45,124 incident dialysis patients initiating and receiving their care from 2003–2010 with complete outcome ascertainment through 2010), (3) the United States Renal Data System (333,308 incident dialysis patients from 2006–2009 with complete outcome ascertainment through 2010), and (4) the Cleveland Clinic Foundation Chronic Kidney Disease Registry (53,399 patients with chronic kidney disease with outcome ascertainment from 2005 through 2009). We ascertain patient reported outcomes (i.e., health-related quality of life), morbidity, and mortality using clinical and administrative data, and data obtained from national death indices. We use advanced statistical methods (e.g., propensity scoring and marginal structural modeling) to account for potential biases of our study designs. All data are de-identified for analyses. The conduct of studies and dissemination of findings are guided by input from Stakeholders in the ESRD community. Discussion The DEcIDE Patient Outcomes in ESRD Study will provide needed evidence regarding the effectiveness of common treatments employed for dialysis patients. Carefully planned dissemination strategies to the ESRD community will enhance studies’ impact on clinical care and patients’ outcomes. PMID:23217181
Cleemput, Irina; De Laet, Chris
2013-05-01
Treatment costs of end-stage renal disease with dialysis are high and vary between dialysis modalities. Public healthcare payers aim at stimulating the use of less expensive dialysis modalities, with maintenance of healthcare quality. This study examines the effects of Belgian financial incentive mechanisms for the use of low-cost dialysis treatments. First, the costs of different dialysis modalities were calculated from the hospital's perspective. Data were obtained through a hospital survey. The balance between costs and revenues was simulated for an average Belgian dialysis programme. Incremental profits were calculated in function of the proportion of patients on alternative dialysis modalities. Hospital haemodialysis is the most expensive modality per patient year, followed by peritoneal dialysis and finally satellite haemodialysis. Under current reimbursement rules mean profits of a dialysis programme are maximal if about 28% of patients are treated with a low-cost dialysis modality. This is only slightly lower than the observed percentage in Belgian dialysis centres in the same period. In Belgium, the financial incentives for the use of low-cost dialysis modalities only had a modest impact due to the continuing profits that could be generated by high-cost dialysis. Profit neutrality is crucial for the success of any financial incentive mechanism for low-cost dialysis modalities. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
The Importance of Dispersal for Bacterial Community Composition and Functioning
Lindström, Eva S.; Östman, Örjan
2011-01-01
We conducted a metacommunity experiment to investigate the role of dispersal for bacterial community composition (BCC) and function of freshwater bacteria. Bacteria were dispersed from a common source pool into three different lake communities in their natural lake water. The experiment was conducted in dialysis bags to enable a decoupling between a change in the local environment and dispersal. BCC was determined by terminal restriction fragment length polymorphism (tRFLP) of the 16S rRNA gene. We show that the greatest changes in BCC occurred between 10% and 43% of dispersal of standing stock per day. Functioning, measured as growth rate, was also affected by dispersal in all three communities but the qualitative pattern differed between communities, sometimes showing a hump-shaped relationship to dispersal and sometimes decreasing with increasing dispersal. In all waters, functioning was related to BCC. Our results show that dispersal does affect BCC and functioning but that high dispersal rates are needed. Further, the effect of dispersal on BCC and function seem to depend on the quality of the habitat to which bacteria disperse into. PMID:21998714
Can dialysis patients be accurately identified using healthcare claims data?
Taneja, Charu; Berger, Ariel; Inglese, Gary W; Lamerato, Lois; Sloand, James A; Wolff, Greg G; Sheehan, Michael; Oster, Gerry
2014-01-01
While health insurance claims data are often used to estimate the costs of renal replacement therapy in patients with end-stage renal disease (ESRD), the accuracy of methods used to identify patients receiving dialysis - especially peritoneal dialysis (PD) and hemodialysis (HD) - in these data is unknown. The study population consisted of all persons aged 18 - 63 years in a large US integrated health plan with ESRD and dialysis-related billing codes (i.e., diagnosis, procedures) on healthcare encounters between January 1, 2005, and December 31, 2008. Using billing codes for all healthcare encounters within 30 days of each patient's first dialysis-related claim ("index encounter"), we attempted to designate each study subject as either a "PD patient" or "HD patient." Using alternative windows of ± 30 days, ± 90 days, and ± 180 days around the index encounter, we reviewed patients' medical records to determine the dialysis modality actually received. We calculated the positive predictive value (PPV) for each dialysis-related billing code, using information in patients' medical records as the "gold standard." We identified a total of 233 patients with evidence of ESRD and receipt of dialysis in healthcare claims data. Based on examination of billing codes, 43 and 173 study subjects were designated PD patients and HD patients, respectively (14 patients had evidence of PD and HD, and modality could not be ascertained for 31 patients). The PPV of codes used to identify PD patients was low based on a ± 30-day medical record review window (34.9%), and increased with use of ± 90-day and ± 180-day windows (both 67.4%). The PPV for codes used to identify HD patients was uniformly high - 86.7% based on ± 30-day review, 90.8% based on ± 90-day review, and 93.1% based on ± 180-day review. While HD patients could be accurately identified using billing codes in healthcare claims data, case identification was much more problematic for patients receiving PD. Copyright © 2014 International Society for Peritoneal Dialysis.
Lovell, Sarah; Walker, Robert J; Schollum, John B W; Marshall, Mark R; McNoe, Bronwen M; Derrett, Sarah
2017-01-01
Background Issues related to renal replacement therapy in elderly people with end stage kidney disease (ESKD) are complex. There is inadequate empirical data related to: decision-making by older populations, treatment experiences, implications of dialysis treatment and treatment modality on quality of life, and how these link to expectations of ageing. Study population Participants for this study were selected from a larger quantitative study of dialysis and predialysis patients aged 65 years or older recruited from three nephrology services across New Zealand. All participants had reached chronic kidney disease (CKD) stage 5 and had undergone dialysis education but had not started dialysis or recently started dialysis within the past 6 months. Methodology Serial qualitative interviews were undertaken to explore the decision-making processes and subsequent treatment experiences of patients with ESKD. Analytical approach: A framework method guided the iterative process of analysis. Decision-making codes were generated within NVivo software and then compared with the body of the interviews. Results Interviews were undertaken with 17 participants. We observed that decision-making was often a fluid process, rather than occurring at a single point in time, and was heavily influenced by perceptions of oneself as becoming old, social circumstances, life events and health status. Limitations This study focuses on participants' experiences of decision-making about treatment and does not include perspectives of their nephrologists or other members of the nephrology team. Conclusions Older patients often delay dialysis as an act of self-efficacy. They often do not commit to a dialysis decision following predialysis education. Delaying decision-making and initiating dialysis were common. This was not seen by participants as a final decision about therapy. Predialysis care and education should be different for older patients, who will delay decision-making until the time of facing obvious uraemic symptoms, threatening blood tests or paternalistic guidance from their nephrologist. Trial registration number Australasian Clinical Trials Registry ACTRN 12611000024943; results. PMID:28360253
Gupta, Amit; Jain, Gaurav; Kaur, Manpreet; Jaryal, Ashok Kumar; Deepak, Kishore Kumar; Bhowmik, Dipankar; Agarwal, Sanjay Kumar
2016-04-01
Peritoneal dialysis patients have high cardiovascular morbidity and mortality. The underlying mechanism of cardiovascular dysfunction remains unclear. Large arterial stiffness in chronic kidney disease (CKD) patients leads to increase in pulse wave velocity (PWV) and decrease in baroreflex sensitivity (BRS). Impairment in baroreflex function could be attributed to the alteration in mechanical properties of large vessels due to arterial remodeling observed in these patients. The present study was designed to study the association of BRS and PWV in peritoneal dialysis (PD) patients. 42 CKD patients (21--without dialysis and 21--on PD) and 25 healthy controls were recruited in this study. BRS was determined by spontaneous sequence method. Short-term heart rate variability (HRV) and blood pressure variability (BPV) were assessed using power spectrum analysis of RR intervals and systolic blood pressure by time domain and frequency domain analysis. Arterial stiffness indices were assessed by carotid-femoral PWV using Sphygmocor Vx device (AtCor Medical, Australia). CKD patients had significantly high PWV and low BRS as compared to healthy controls. PWV had a significant negative correlation with BRS in CKD patients (Spearman r = -0.7049, P < 0.0001; BRS-Systolic BP). On subgroup analysis, PWV was higher with lower BRS in CKD patients on peritoneal dialysis (CKD-PD) as compared to those not on dialysis (CKD-ND). Negative relationship between PWV and BRS was found in both the groups. In addition, BRS was found to have a positive correlation with HRV in CKD patients as well as both the subgroups. Reduction in BRS is strongly associated with increase in PWV in PD patients. Large arterial stiffness probably explains this simultaneous impairment in baroreflex functioning and increase in pulse wave velocity observed in these patients. CKD patients are characterized by poor hemodynamic profile (low BRS, high PWV, and low HRV), and peritoneal dialysis patients had further worsened profile as compared to non-dialysis group.
Mapiye, Darlington; Swanepoel, Charles R.; Bello, Aminu K.; Ratsela, Andrew R.; Okpechi, Ikechi G.
2016-01-01
Background Dialysis therapy for end-stage renal disease (ESRD) continues to be the readily available renal replacement option in developing countries. While the impact of rural/remote dwelling on mortality among dialysis patients in developed countries is known, it remains to be defined in sub-Saharan Africa. Methods A single-center database of end-stage renal disease patients on chronic dialysis therapies treated between 2007 and 2014 at the Polokwane Kidney and Dialysis Centre (PKDC) of the Pietersburg Provincial Hospital, Limpopo South Africa, was retrospectively reviewed. All-cause, cardiovascular, and infection-related mortalities were assessed and associated baseline predictors determined. Results Of the 340 patients reviewed, 52.1% were male, 92.9% were black Africans, 1.8% were positive for the human immunodeficiency virus (HIV), and 87.5% were rural dwellers. The average distance travelled to the dialysis centre was 112.3 ± 73.4 Km while 67.6% of patients lived in formal housing. Estimated glomerular filtration rate (eGFR) at dialysis initiation was 7.1 ± 3.7 mls/min while hemodialysis (HD) was the predominant modality offered (57.1%). Ninety-two (92) deaths were recorded over the duration of follow-up with the majority (34.8%) of deaths arising from infection-related causes. Continuous ambulatory peritoneal dialysis (CAPD) was a significant predictor of all-cause mortality (HR: 1.62, CI: 1.07–2.46) and infection-related mortality (HR: 2.27, CI: 1.13–4.60). On multivariable cox regression, CAPD remained a significant predictor of all-cause mortality (HR: 2.00, CI: 1.29–3.10) while the risk of death among CAPD patients was also significantly modified by diabetes mellitus (DM) status (HR: 4.99, CI: 2.13–11.71). Conclusion CAPD among predominantly rural dwelling patients in the Limpopo province of South Africa is associated with an increased risk of death from all-causes and infection-related causes. PMID:27300372
Toussaint, Nigel D; McMahon, Lawrence P; Dowling, Gregory; Holt, Stephen G; Smith, Gillian; Safe, Maria; Knight, Richard; Fair, Kathleen; Linehan, Leanne; Walker, Rowan G; Power, David A
2017-01-01
♦ BACKGROUND: Increased demand for treatment of end-stage kidney disease has largely been accommodated by a costly increase in satellite hemodialysis (SHD) in most jurisdictions. In the Australian State of Victoria, a marked regional variation in the uptake of home-based dialysis suggests that use of home therapies could be increased as an alternative to SHD. An earlier strategy based solely on increased remuneration had failed to increase uptake of home therapies. Therefore, the public dialysis funder adopted the incidence and prevalence of home-based dialysis therapies as a key performance indicator (KPI) for its health services to encourage greater uptake of home therapies. ♦ METHODS: A KPI data collection and bench-marking program was established in 2012 by the Victorian Department of Health and Human Services, with data provided monthly by all renal units in Victoria using a purpose-designed website portal. A KPI Working Group was responsible for analyzing data each quarter and ensuring indicators remained accurate and relevant and each KPI had clear definitions and targets. We present a prospective, observational study of all dialysis patients in Victoria over a 4-year period following the introduction of the renal KPI program, with descriptive analyses to evaluate the proportion of patients using home therapies as well as home dialysis modality survival. ♦ RESULTS: Following the introduction of the KPI program, the net growth of dialysis patient numbers in Victoria remained stable over 4 years, at 75 - 80 per year (approximately 4%). However, unlike the previous decade, about 40% of this growth was through an increase in home dialysis, which was almost exclusively peritoneal dialysis (PD). The increase was identified particularly in the young (20 - 49) and the elderly (> 80). Disappointingly, however, 67% of these incident patients ceased PD within 2 years of commencement, 46% of whom transferred to SHD. ♦ CONCLUSIONS: Introduction of a KPI program was associated with an increased uptake of PD but not home HD. This change in clinical practice restricted growth of SHD and reduced pressure on satellite services. The effect was offset by a modest PD technique survival. Many patients in whom PD was unsuccessful were subsequently transferred to SHD rather than home HD. Copyright © 2017 International Society for Peritoneal Dialysis.
Practice patterns, case mix, Medicare payment policy, and dialysis facility costs.
Hirth, R A; Held, P J; Orzol, S M; Dor, A
1999-01-01
OBJECTIVE: To evaluate the effects of case mix, practice patterns, features of the payment system, and facility characteristics on the cost of dialysis. DATA SOURCES/STUDY SETTING: The nationally representative sample of dialysis units in the 1991 U.S. Renal Data System's Case Mix Adequacy (CMA) Study. The CMA data were merged with data from Medicare Cost Reports, HCFA facility surveys, and HCFA's end-stage renal disease patient registry. STUDY DESIGN: We estimated a statistical cost function to examine the determinants of costs at the dialysis unit level. PRINCIPAL FINDINGS: The relationship between case mix and costs was generally weak. However, dialysis practices (type of dialysis membrane, membrane reuse policy, and treatment duration) did have a significant effect on costs. Further, facilities whose payment was constrained by HCFA's ceiling on the adjustment for area wage rates incurred higher costs than unconstrained facilities. The costs of hospital-based units were considerably higher than those of freestanding units. Among chain units, only members of one of the largest national chains exhibited significant cost savings relative to independent facilities. CONCLUSIONS: Little evidence showed that adjusting dialysis payment to account for differences in case mix across facilities would be necessary to ensure access to care for high-cost patients or to reimburse facilities equitably for their costs. However, current efforts to increase dose of dialysis may require higher payments. Longer treatments appear to be the most economical method of increasing the dose of dialysis. Switching to more expensive types of dialysis membranes was a more costly means of increasing dose and hence must be justified by benefits beyond those of higher dose. Reusing membranes saved money, but the savings were insufficient to offset the costs associated with using more expensive membranes. Most, but not all, of the higher costs observed in hospital-based units appear to reflect overhead cost allocation rather than a difference in real resources devoted to treatment. The economies experienced by the largest chains may provide an explanation for their recent growth in market share. The heterogeneity of results by chain size implies that characterizing units using a simple chain status indicator variable is inadequate. Cost differences by facility type and the effects of the ongoing growth of large chains are worthy of continued monitoring to inform both payment policy and antitrust enforcement. PMID:10029498
Practice patterns, case mix, Medicare payment policy, and dialysis facility costs.
Hirth, R A; Held, P J; Orzol, S M; Dor, A
1999-02-01
To evaluate the effects of case mix, practice patterns, features of the payment system, and facility characteristics on the cost of dialysis. The nationally representative sample of dialysis units in the 1991 U.S. Renal Data System's Case Mix Adequacy (CMA) Study. The CMA data were merged with data from Medicare Cost Reports, HCFA facility surveys, and HCFA's end-stage renal disease patient registry. We estimated a statistical cost function to examine the determinants of costs at the dialysis unit level. The relationship between case mix and costs was generally weak. However, dialysis practices (type of dialysis membrane, membrane reuse policy, and treatment duration) did have a significant effect on costs. Further, facilities whose payment was constrained by HCFA's ceiling on the adjustment for area wage rates incurred higher costs than unconstrained facilities. The costs of hospital-based units were considerably higher than those of freestanding units. Among chain units, only members of one of the largest national chains exhibited significant cost savings relative to independent facilities. Little evidence showed that adjusting dialysis payment to account for differences in case mix across facilities would be necessary to ensure access to care for high-cost patients or to reimburse facilities equitably for their costs. However, current efforts to increase dose of dialysis may require higher payments. Longer treatments appear to be the most economical method of increasing the dose of dialysis. Switching to more expensive types of dialysis membranes was a more costly means of increasing dose and hence must be justified by benefits beyond those of higher dose. Reusing membranes saved money, but the savings were insufficient to offset the costs associated with using more expensive membranes. Most, but not all, of the higher costs observed in hospital-based units appear to reflect overhead cost allocation rather than a difference in real resources devoted to treatment. The economies experienced by the largest chains may provide an explanation for their recent growth in market share. The heterogeneity of results by chain size implies that characterizing units using a simple chain status indicator variable is inadequate. Cost differences by facility type and the effects of the ongoing growth of large chains are worthy of continued monitoring to inform both payment policy and antitrust enforcement.
Hemodialysis and Water Quality
Coulliette, Angela D.; Arduino, Matthew J.
2015-01-01
Over 383,900 individuals in the U.S. undergo maintenance hemodialysis that exposes them to water, primarily in the form of dialysate. The quality of water and associated dialysis solutions have been implicated in adverse patient outcomes and is therefore critical. The Association for the Advancement of Medical Instrumentation has published both standards and recommended practices that address both water and the dialyzing solutions. Some of these recommendations have been adopted into Federal Regulations by the Centers for Medicare and Medicaid Services as part of the Conditions for Coverage, which includes limits on specific contaminants within water used for dialysis, dialysate, and substitution fluids. Chemical, bacterial, and endotoxin contaminants are health threats to dialysis patients, as shown by the continued episodic nature of outbreaks since the 1960s causing at least 592 cases and 16 deaths in the U.S. The importance of the dialysis water distribution system, current standards and recommendations, acceptable monitoring methods, a review of chemical, bacterial, and endotoxin outbreaks, and infection control programs are discussed. PMID:23859187
Peritoneal Dialysis Catheter Insertion.
Crabtree, John H; Chow, Kai-Ming
2017-01-01
The success of peritoneal dialysis as renal-replacement therapy depends on a well-functioning peritoneal catheter. Knowledge of best practices in catheter insertion can minimize the risk of catheter complications that lead to peritoneal dialysis failure. The catheter placement procedure begins with preoperative assessment of the patient to determine the most appropriate catheter type, insertion site, and exit site location. Preoperative preparation of the patient is an instrumental step in facilitating the performance of the procedure, avoiding untoward events, and promoting the desired outcome. Catheter insertion methods include percutaneous needle-guidewire with or without image guidance, open surgical dissection, peritoneoscopic procedure, and surgical laparoscopy. The insertion technique used often depends on the geographic availability of material resources and local provider expertise in placing catheters. Independent of the catheter implantation approach, adherence to a number of universal details is required to ensure the best opportunity for creating a successful long-term peritoneal access. Finally, appropriate postoperative care and catheter break-in enables a smooth transition to dialysis therapy. Copyright © 2017 Elsevier Inc. All rights reserved.
Giorda, Carlo Bruno; Carnà, Paolo; Salomone, Mario; Picariello, Roberta; Costa, Giuseppe; Tartaglino, Barbara; Gnavi, Roberto
2018-04-20
To study the incidence of and the factors associated with renal dialysis and transplantation in type 1 (T1DM) and type 2 diabetes (T2DM). Data on individuals who had received dialysis treatment or renal transplant between 1 January 2004 and 31 December 2013 were extracted from the regional administrative database (Piedmont, Italy), and the crude (cumulative) incidence of dialysis was calculated. Overall cumulative survival was estimated using the Kaplan-Meier method and compared using the log-rank test. Poisson regression was used to estimate adjusted rate ratios for potential predictors of renal transplant or death. A total of 7401 persons started dialysis treatment during the decade, with a 10-year cumulative crude incidence of 16.8/100,000. Incidence was stable and consistently eightfold higher in persons with T2DM (tenfold higher in T1DM) compared to those without diabetes. The risk of dialysis in T1DM was about double that of T2DM. The mortality rate was significantly higher in diabetics than in non-diabetes (241.4/1000 vs. 153.99/1000 person-years). During the decade 2004-2013, 893 patients underwent a kidney transplant. Transplantation rates were significantly lower for diabetics than non-diabetics (16.5/1000 vs. 42.9/1000 person-years). In the past decade, the incidence of dialysis has stabilized in both the general population and in diabetics in whom it remains far higher by comparison. Also mortality rates are higher, with a worse prognosis for T1DM. Diabetes poses a barrier to allotransplantation, and efforts should be made to overcome this limitation.
Kjaergaard, Krista D; Jensen, Jens D; Jespersen, Bente; Rehling, Michael
2011-12-01
In dialysis patients, longer survival is associated with a higher residual renal function. Randomized controlled trials are conducted to clarify how residual renal function can be preserved. However, existing methods for measuring residual renal function are uncertain and there is a need for establishing a standard for measurements of glomerular filtration rate (GFR) in dialysis patients. ⁵¹Cr-EDTA clearances in plasma, urine, and dialysate were evaluated in a sample of 12 hemodialysis and 12 peritoneal dialysis patients. The patients' condition was generally stable, and all patients were investigated twice within 4-10 days. Plasma clearances of ⁵¹Cr-EDTA for all patients ranged between 2.1 and 30.8 mL/min/1.73 m², whereas urinary ⁵¹Cr-EDTA clearances ranged from 0.7-20.0 mL/min/1.73 m². This difference was statistically significant (p < 0.001). Week-to-week reproducibility expressed as coefficients of variation were below or equal to 10% for plasma clearances and 13% for urinary clearances in hemodialysis patients and 14% in peritoneal dialysis patients. This study demonstrated a difference between ⁵¹Cr-EDTA plasma and urinary clearances in dialysis patients. Plasma clearance of ⁵¹Cr-EDTA had the best reproducibility. For repeated measurements as in clinical prospective trials, we recommend ⁵¹Cr-EDTA plasma clearance based on blood sampling at 5 + 24 hours with subtraction of ⁵¹Cr-EDTA dialysate clearance in peritoneal dialysis patients. Further studies are needed to corroborate our findings.
2014-01-01
Background Chronic kidney disease has become a public health problem worldwide. Its terminal stage requires renal replacement therapy – dialysis or transplantation – for the maintenance of life, resulting in high economic and social costs. Though the number of patients with end-stage renal disease treated by dialysis in Brazil is among the highest in the world, current estimates of incidence and prevalence are imprecise. Our aim is to describe incidence and prevalence trends and the epidemiologic profile of end-stage renal disease patients receiving publically-financed dialysis in Brazil between 2000 and 2012. Methods We internally linked records of the High Complexity Procedure Authorization/Renal Replacement Therapy (APAC/TRS) system so as to permit analyses of incidence and prevalence of dialysis over the period 2000-2012. We characterized temporal variations in the incidence and prevalence using Joinpoint regression. Results Over the period, 280,667 patients received publically-financed dialysis, 57.2% of these being male. The underlying disease causes listed were hypertension (20.8%), diabetes (12.0%) and glomerulonephritis (7.7%); for 42.3%, no specific cause was recorded. Hemodialysis was the therapeutic modality in 90.1%. Over this period, prevalence increased 47%, rising 3.6% (95% CI 3.2% - 4.0%)/year. Incidence increased 20%, or 1.8% (1.1% – 2.5%)/year. Incidence increased in both sexes, in all regions of the country and particularly in older age groups. Conclusions Incidence and prevalence of end-stage renal disease receiving publically-financed dialysis treatment has increased notably. The linkage approach developed will permit continuous future monitoring of these indicators. PMID:25008169
Koefoed, Mette; Kromann, Charles Boy; Juliussen, Sophie Ryberg; Hvidtfeldt, Danni; Ekelund, Bo; Frandsen, Niels Erik; Marckmann, Peter
2016-01-01
Maintenance dialysis patients are at increased risk of abnormal nutritional status due to numerous causative factors, both nutritional and non-nutritional. The present study assessed the current prevalence of protein-energy wasting, low lean body mass index and obesity in maintenance dialysis patients, and compared different methods of nutritional assessment. In a cross-sectional study conducted in 2014 at Roskilde Hospital, Denmark, we performed anthropometry (body weight, skinfolds, mid-arm, waist, and hip circumferences), and determined plasma albumin and normalized protein catabolic rate in order to assess the prevalence of protein-energy wasting, low lean body mass index and obesity in these patients. Seventy-nine eligible maintenance dialysis patients participated. The prevalence of protein-energy wasted patients was 4% (95% CI: 2-12) as assessed by the coexistence of low lean body mass index and low fat mass index. Low lean body mass index was seen in 32% (95% CI: 22-44). Obesity prevalence as assessed from fat mass index was 43% (95% CI: 32-55). Coexistence of low lean body mass index and obesity was seen in 10% (95% CI: 5-19). The prevalence of protein-energy wasting and obesity varied considerably, depending on nutritional assessment methodology. Our data indicate that protein-energy wasting is uncommon, whereas low lean body mass index and obesity are frequent conditions among patients in maintenance dialysis. A focus on how to increase and preserve lean body mass in dialysis patients is suggested in the future. In order to clearly distinguish between shortage, sufficiency and abundance of protein and/or fat deposits in maintenance dialysis patients, we suggest the simple measurements of lean body mass index and fat mass index.
Chang, Ray-E; Tsai, Ya-Hsing; Myrtle, Robert C
2015-11-01
This study examined whether outpatient haemodialysis providers changed their treatment practices with the establishment of an outpatient dialysis global budget (ODGB) through analysing the outpatient visits and medication received by those patients. A sample of 4668 observations (patient year) of 1350 haemodialysis with hypertension (HH) patients and 4668 observations of 1436 non-HH (NHH) patients were drawn from the National Health Insurance Research Database over the years from 1999 to 2005. The impact of ODGB on hypertension-related outpatient utilization of HH was estimated using the difference in difference (DID) method and examined in three stages: (1) the fee for service stage, the pre-ODGB (2000), (2) the phase-in stage (2001-2002) and (3) the post-ODGB stage (2003-2005). ODGB implementation did not affect the number of dialysis visits for HH patients. However, it did lead to a reduction in fees for antihypertension drugs used by haemodialysis facilities. There was an increase of 4.06 visits per patient per year (P < 0.001) in the number of non-dialysis outpatient with antihypertensive drugs visits for HH patients compared with the control group. The total fees for antihypertensive drugs for HH patients increased by New Taiwan Dollars (NT$)13 008 (P < 0.001) per patient per year relative to the control group after the implementation of ODGB. As ODGB was implemented, HH patients received fewer antihypertensive drugs during their dialysis visit. In addition, there was an increase in the number of non-dialysis outpatient visits by HH patients as well as increased payment in the drugs associated with their non-dialysis outpatient visits compared with the control group. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine © The Author 2014; all rights reserved.
Decision making around dialysis options.
Mooney, Andrew
2009-01-01
We have previously shown that information given to patients approaching end stage renal failure to make an informed decision about dialysis modality is frequently incomplete and difficult to comprehend [1]. We have now studied whether there are differences in decisions made about dialysis modality according to the method employed to deliver this information. In an online study, 784 participants viewed treatment information about hemodialysis (HD) and continuous cycling peritoneal dialysis (CCPD) and completed a questionnaire. A control group saw only basic information, but otherwise treatment information was varied by format (written or videotaped) and who presented the information (male or female; 'patient' or 'doctor'). The information was carefully controlled to ensure comparable content and comprehensibility. In addition to collection of demographic data, measures included: treatment choice, reasons for treatment choice, decisional conflict, need for affect, need for cognition, decision regret, quality of information, previous knowledge of end-stage renal failure and social comparison. There were a number of differences in choices made among subjects who viewed written or video information presented as if by doctors or patients. There was a statistically significant effect that subjects chose the dialysis modality recommended by the patient (whether CCPD or HD). There was no significant effect of the gender of the person presenting information on the modality chosen. However, among participants, females were more satisfied with the information presented, and more likely to choose CCPD (compared to male participants). Subjects' style of information processing (need for cognition/need for affect) had no significant effect on choice of dialysis modality. There was a higher drop-out rate among subjects viewing videotaped information. The use of testimonials might bias patients decision making regarding dialysis options and until these effects are understood, they should be used with caution.
NASA Astrophysics Data System (ADS)
Ares, A.; Fernández, J. A.; Carballeira, A.; Aboal, J. R.
2014-09-01
The moss bag technique is a simple and economical environmental monitoring tool used to monitor air quality. However, routine use of the method is not possible because the protocols involved have not yet been standardized. Some of the most variable methodological aspects include (i) selection of moss species, (ii) ratio of moss weight to surface area of the bag, (iii) duration of exposure, and (iv) height of exposure. In the present study, the best option for each of these aspects was selected on the basis of the mean concentrations and data replicability of Cd, Cu, Hg, Pb and Zn measured during at least two exposure periods in environments affected by different degrees of contamination. The optimal choices for the studied aspects were the following: (i) Sphagnum denticulatum, (ii) 5.68 mg of moss tissue for each cm-2 of bag surface, (iii) 8 weeks of exposure, and (iv) 4 m height of exposure. Duration of exposure and height of exposure accounted for most of the variability in the data. The aim of this methodological study was to provide data to help establish a standardized protocol that will enable use of the moss bag technique by public authorities.
Lee, Martin B; Bargman, Joanne M
2016-11-01
To clarify misconceptions about the feasibility and risks of peritoneal dialysis that unnecessarily limit peritoneal dialysis uptake or continuation in patients for whom peritoneal dialysis is the preferred dialysis modality. The inappropriate choice of haemodialysis as a result of these misconceptions contributes to low peritoneal dialysis penetrance, increases transfer from peritoneal dialysis to haemodialysis, increases expenditure on haemodialysis and compromises quality of life for these patients. Peritoneal dialysis is an excellent renal replacement modality that is simple, cost-effective and provides comparable clinical outcomes to conventional in-centre haemodialysis. Unfortunately, many patients are deemed unsuitable to start or continue peritoneal dialysis because of false or inaccurate beliefs about peritoneal dialysis. Here, we examine some of these 'myths' and critically review the evidence for and against each of them. We review the feasibility and risk of peritoneal dialysis in patients with prior surgery, ostomies, obesity and mesh hernia repairs. We examine the fear of mediastinitis with peritoneal dialysis after coronary artery bypass graft surgery and the belief that the use of hypertonic glucose dialysate causes peritoneal membrane failure. By clarifying common myths about peritoneal dialysis, we hope to reduce overly cautious practices surrounding this therapy.
Prevalence-Based Targets Underestimate Home Dialysis Program Activity and Requirements for Growth.
Bevilacqua, Micheli U; Er, Lee; Copland, Michael A; Singh, R Suneet; Jamal, Abeed; Dunne, Órla Marie; Brumby, Catherine; Levin, Adeera
2018-01-01
Many renal programs have targets to increase home dialysis prevalence. Data from a large Canadian home dialysis program were analyzed to determine if home dialysis prevalence accurately reflects program activity and whether prevalence-based assessments adequately reflect the work required for program growth. Data from home dialysis programs in British Columbia, Canada, were analyzed from 2005 to 2015. Prevalence data were compared to dialysis activity data including intakes and exits to describe program turnover. Using current attrition rates, recruitment rates needed to increase home dialysis prevalence proportions were identified. We analyzed 7,746 patient-years of peritoneal dialysis (PD) and 1,362 patient-years of home hemodialysis (HHD). The proportion of patients on home dialysis increased by 3.34% over the ten years examined, while the number of prevalent home dialysis patients increased 2.65% per year and the number of patients receiving home dialysis at any time in the year increased 4.04% per year. For every 1 patient net home dialysis growth, 13.6 new patients were recruited. Patient turnover included higher rates of transplantation in home dialysis than facility-based HD. Overall, the proportion dialyzing at home increased from 29.3 to 32.6%. There is high patient turnover in home dialysis such that program prevalence is an incomplete marker of total program activity. This turnover includes high rates of transplantation, which is a desirable interaction that affects home dialysis prevalence. The shortcomings of this commonly used metric are important for renal programs to consider, and better understanding of the activities that support home dialysis and the complex trajectories that home dialysis patients follow is needed. Copyright © 2018 International Society for Peritoneal Dialysis.
Lukowsky, Lilia R; Mehrotra, Rajnish; Kheifets, Leeka; Arah, Onyebuchi A; Nissenson, Allen R; Kalantar-Zadeh, Kamyar
2013-04-01
There are conflicting research results about the survival differences between hemodialysis and peritoneal dialysis, especially during the first 2 years of dialysis treatment. Given the challenges of conducting randomized trials, differential rates of modality switch and transplantation, and time-varying confounding in cohort data during the first years of dialysis treatment, use of novel analytical techniques in observational cohorts can help examine the peritoneal dialysis versus hemodialysis survival discrepancy. This study examined a cohort of incident dialysis patients who initiated dialysis in DaVita dialysis facilities between July of 2001 and June of 2004 and were followed for 24 months. This study used the causal modeling technique of marginal structural models to examine the survival differences between peritoneal dialysis and hemodialysis over the first 24 months, accounting for modality change, differential transplantation rates, and detailed time-varying laboratory measurements. On dialysis treatment day 90, there were 23,718 incident dialysis-22,360 hemodialysis and 1,358 peritoneal dialysis-patients. Incident peritoneal dialysis patients were younger, had fewer comorbidities, and were nine and three times more likely to switch dialysis modality and receive kidney transplantation over the 2-year period, respectively, compared with hemodialysis patients. In marginal structural models analyses, peritoneal dialysis was associated with persistently greater survival independent of the known confounders, including dialysis modality switch and transplant censorship (i.e., death hazard ratio of 0.52 [95% confidence limit 0.34-0.80]). Peritoneal dialysis seems to be associated with 48% lower mortality than hemodialysis over the first 2 years of dialysis therapy independent of modality switches or differential transplantation rates.
Chonhenchob, Vanee; Kamhangwong, Damrongpol; Kruenate, Jittiporn; Khongrat, Krittaphat; Tangchantra, Nantavat; Wichai, Uthai; Singh, S Paul
2011-03-15
Preharvest bagging has been shown to improve development and quality of fruits. Different light transmittance bags showed different effects on fruit quality. This study presents the benefits of using newly developed plastic bagging materials with different wavelength-selective characteristics for mangoes (cv. Nam Dok Mai #4). Mangoes were bagged at 45 days after full bloom (DAFB) and randomly harvested at 65, 75, 85, 95, and 105 DAFB. The bags were removed on the harvest days. The wavelength-selective bags (no pigment, yellow, red, blue/violet, blue) were compared with the Kraft paper bag with black paper liner, which is currently used commercially for several fruits, and with non-bagging as a control. Bagging significantly (p⩽0.05) reduced diseases and blemishes. Mango weight at 95 DAFB was increased approximately 15% by VM and V plastic bagging, as compared to paper bagging and control. Plastic bagging accelerated mango ripening as well as growth. Plastic-bagged mangoes reached maturity stage at 95 DAFB, while non-bagged mangoes reached maturity stage at 105 DAFB. Paper bagging resulted in a pale-yellow peel beginning at 65 DAFB, while plastic bagging improved peel glossiness. Preharvest bagging with different wavelength-selective materials affected mango development and quality. Bagging mangoes with VM and V materials could reduce peel defects and diseases, increase weight, size, and sphericity, improve peel appearance, and shorten the development periods of mangoes. The results suggest a favorable practice using the newly developed VM and V plastic bags in the production of mangoes, and possibly other fruits as well. Copyright © 2010 Society of Chemical Industry.
2013-01-01
Background The majority of bicarbonate based dialysis fluids are acidified with acetate. Citrate, a well known anticoagulant and antioxidant, has been suggested as a biocompatible alternative. The objective of this study was to evaluate short term safety and biocompatibility of a citrate containing acetate-free dialysis fluid. Methods Twenty four (24) patients on maintenance dialysis three times per week, 13 on on-line hemodiafiltration (HDF) and 11 on hemodialysis (HD), were randomly assigned to start with either citrate dialysis fluid (1 mM citrate, 1.5 mM calcium) or control fluid (3 mM acetate, 1.5 mM calcium) in an open-labeled cross-over trial (6 + 6 weeks with 8 treatments wash-out in between). Twenty (20) patients, 11 on HDF and 9 on HD were included in the analyses. Main objective was short term safety assessed by acid–base status, plasma ionized calcium and parathyroid hormone (PTH). In addition, biocompatibility was assessed by markers of inflammation (pentraxin 3 (PTX-3), CRP, IL-6, TNF-α and IL-1β) and thrombogenicity (activated partial thromboplastin time (APTT) and visual clotting scores). Results No differences dependent on randomization order or treatment mode (HD vs. HDF) were detected. Citrate in the dialysis fluid reduced the intra-dialytic shift in pH (+0.04 week 6 vs. +0.06 week 0, p = 0.046) and base excess (+3.9 mM week 6 vs. +5.6 mM week 0, p = 0.006) over the study period. Using the same calcium concentration (1.5 mM), citrate dialysis fluid resulted in lower post-dialysis plasma ionized calcium level (1.10 mM vs. 1.27 mM for control, p < 0.0001) and higher post-dialysis PTH level (28.8 pM vs. 14.7 pM for control, p < 0.0001) while pre-dialysis levels were unaffected. Citrate reduced intra-dialytic induction of PTX-3 (+1.1 ng/ml vs. +1.4 ng/ml for control, p = 0.04) but had no effect on other markers of inflammation or oxidative stress. Citrate reduced visual clotting in the arterial air chamber during HDF (1.0 vs. 1.8 for control, p = 0.03) and caused an intra-dialytic increase in APTT (+6.8 s, p = 0.003) without affecting post-dialysis values compared to control. Conclusions During this small short term study citrate dialysis fluid was apparently safe to use in HD and on-line HDF treatments. Indications of reduced treatment-induced inflammation and thrombogenicity suggest citrate as a biocompatible alternative to acetate in dialysis fluid. However, the results need to be confirmed in long term studies. Trial registration ISRCTN: ISRCTN28536511 PMID:24103587
Advanced glycation end products in clinical nephrology.
Kalousová, M; Zima, T; Tesar, V; Stípek, S; Sulková, S
2004-01-01
As a result of oxidative and carbonyl stress, advanced glycation end products (AGEs) are involved in the pathogenesis of severe and frequent diseases and their fatal vascular/cardiovascular complications, i.e. diabetes mellitus and its complications (nephropathy, angiopathy, neuropathy and retinopathy, renal failure and uremic and dialysis-associated complications), atherosclerosis and dialysis-related amyloidosis, neurodegenerative diseases, and rheumatoid arthritis. They are formed via non-enzymatic glycation which is specifically enhanced through the presence of oxidative and carbonyl stress, and their ability to form glycoxidation products in peptide and protein structures finally modulating or inducing biological reactivity. Food can be another source of AGEs; however, high serum AGEs in hemodialysis patients might reflect nutritional status better. Several methods of renal replacement therapy have been studied in connection with the AGE removal, but unfortunately the possibilities are still unsatisfactory even if high flux dialysis, hemofiltration, or hemodiafiltration give better results than conventional low flux dialysis. AGEs are currently being studied in the patients on peritoneal dialysis as their precursors can be formed in the dialysis fluid. AGEs can cause damage to the peritoneum and so a loss of ultrafiltration capacity. Many compounds give promising results in AGE inhibition (inhibition of formation of AGEs, inhibition of their action or degradation of AGEs), are tested for these properties, and eventually undergo clinical studies (e.g. aminoguanidine, OPB-9195, pyridoxamine, antioxidants, N-phenacylthiazolium bromide, antihypertensive drugs, angiotensin-converting enzyme inhibitors and angiotensin II receptor-1 antagonists). Copyright 2004 S. Karger AG, Basel
Hirth, Richard A; Turenne, Marc N; Wheeler, John RC; Pan, Qing; Ma, Yu; Messana, Joseph M
2009-01-01
Objective To characterize the influence of dialysis facilities and nephrologists on resource use and patient outcomes in the dialysis population and to illustrate how such information can be used to inform payment system design. Data Sources Medicare claims for all hemodialysis patients for whom Medicare was the primary payer in 2004, combined with the Medicare Enrollment Database and the CMS Medical Evidence Form (CMS Form 2728), which is completed at onset of renal replacement therapy. Study Design Resource use (mainly drugs and laboratory tests) per dialysis session and two clinical outcomes (achieving targets for anemia management and dose of dialysis) were modeled at the patient level with random effects for nephrologist and dialysis facility, controlling for patient characteristics. Results For each measure, both the physician and the facility had significant effects. However, facilities were more influential than physicians, as measured by the standard deviation of the random effects. Conclusions The success of tools such as P4P and provider profiling relies upon the identification of providers most able to enhance efficiency and quality. This paper demonstrates a method for determining the extent to which variation in health care costs and quality of care can be attributed to physicians and institutional providers. Because variation in quality and cost attributable to facilities is consistently larger than that attributable to physicians, if provider profiling or financial incentives are targeted to only one type of provider, the facility appears to be the appropriate locus. PMID:19555398
New Insights into the Effects of Chronic Kidney Failure and Dialysate Exposure on the Peritoneum.
Vlahu, Carmen A; Aten, Jan; de Graaff, Marijke; van Veen, Henk; Everts, Vincent; de Waart, Dirk R; Struijk, Dirk G; Krediet, Raymond T
♦ INTRODUCTION: Chronic uremia and the exposure to dialysis solutions during peritoneal dialysis (PD) induce peritoneal alterations. Using a long-term peritoneal exposure model, we compared the effects of chronic kidney failure (CKD) itself and exposure to either a 'conventional' or a 'biocompatible' dialysis solution on peritoneal morphology and function. ♦ METHODS: Wistar rats (Harlan, Zeist, the Netherlands) were grouped into: normal kidney function (NKF), CKD induced by 70% nephrectomy, CKD receiving daily peritoneal infusions with 3.86% glucose Dianeal (CKDD), or Physioneal (both solutions from Baxter Healthcare, Castlebar, Ireland) (CKDP). At 16 weeks, a peritoneal function test was performed, and histology, ultrastructure, and hydroxyproline content of peritoneal tissue were assessed. ♦ RESULTS: Comparing CKD with NKF, peritoneal transport rates were higher, mesothelial cells (MC) displayed increased number of microvilli, blood and lymph vasculature expanded, vascular basal lamina appeared thicker, with limited areas of duplication, and fibrosis had developed. All alterations, except lymphangiogenesis, were enhanced by exposure to both dialysis fluids. Distinct MC alterations were observed in CKDD and CKDP, the latter displaying prominent basolateral protrusions. In addition, CKDP was associated with a trend towards less fibrosis compared to CKDD. ♦ CONCLUSIONS: Chronic kidney failure itself induced peritoneal alterations, which were in part augmented by exposure to glucose-based dialysis solutions. Overall, the conventional and biocompatible solutions had similar long-term effects on the peritoneum. Importantly, the latter may attenuate the development of fibrosis. Copyright © 2016 International Society for Peritoneal Dialysis.
Ramasubbu, Kumudha; Deswal, Anita; Herdejurgen, Cheryl; Aguilar, David; Frost, Adaani E
2010-01-01
Background Pulmonary hypertension (PH), a disease which carries substantial morbidity and mortality, has been reported to occur in 25%–45% of dialysis patients. No prospective evaluation of the prevalence or clinical significance of PH in chronic dialysis patients in the United States (US) has been undertaken. Methods Echocardiograms were performed prospectively in chronic hemodialysis patients prior to dialysis at a single dialysis center. PH was defined as a tricuspid regurgitant jet ≥2.5 m/s and “more severe PH” as ≥3.0 m/s. Clinical outcomes recovered were all-cause hospitalizations and death at 12 months. Results In a cohort of 90 patients, 42 patients (47%) met the definition of PH. Of those, 18 patients (20%) met the definition of more severe PH. At 12 months, mortality was significantly higher in patients with PH (26%) compared with patients without PH (6%). All-cause hospitalizations were similar in patients with PH and without PH. Echocardiographic findings suggesting impaired left ventricular function and elevated pulmonary capillary wedge pressure were significantly associated with PH. Conclusion This prospective cross-sectional study of a single dialysis unit suggests that PH may be present in nearly half of US dialysis patients and when present is associated with increased mortality. Echocardiographic findings demonstrate an association between elevated filling pressures, elevated pulmonary artery pressures, and higher mortality, suggesting that the PH may be secondary to diastolic dysfunction and compounded by volume overload. PMID:21042428
A quick and effective method of limb preparation with health, safety and efficiency benefits.
Naderi, N; Maw, K; Thomas, M; Boyce, D E; Shokrollahi, K
2012-03-01
Pre-operative limb preparation (PLP) usually involves lifting the limb and holding it in a fixed 'static' posture for several minutes. This is hazardous to theatre staff. Furthermore, 'painting' the limb can be time consuming and difficult areas such as between toes and fingers may remain unsterile. We demonstrate the time efficiency and asepsis achieved using the 'sterile bag' preparation technique. An additional advantage is the ability to prepare and anaesthetise a limb prior to theatre, increasing efficiency substantially for units with a large throughput of cases, such as day-case hand surgery lists. We monitored the duration of PLP in 20 patients using the 'sterile bag' technique compared to 20 patients using a conventional 'painting' method. Additionally, microbiology samples acquired from prepared upper limbs of 27 sequential patients operated on by a single surgeon over a two-month period were sent for culture immediately prior to commencement of surgery. The mean duration of the 'sterile bag' PLP was significantly lower than that of the conventional method (24 seconds vs 85 seconds, p=0.045). The technique can take as little as ten seconds (n=1). Final microbiology reports showed no growth for any of the 27 patients from whom a culture sample was taken. The sterile bag technique is effective in achieving asepsis, has the potential to increase theatre efficiency and reduces manual handling hazards compared to the conventional method. It is now taught to all theatre staff in our hospital during manual handling training. It can be undertaken in approximately ten seconds with practice for the upper limb.
Sampson, Maureen M.; Chambers, David M.; Pazo, Daniel Y.; Moliere, Fallon; Blount, Benjamin C.; Watson, Clifford H.
2015-01-01
Quantifying volatile organic compounds (VOCs) in cigarette smoke is necessary to establish smoke-related exposure estimates and evaluate emerging products and potential reduced-exposure products. In response to this need, we developed an automated, multi-VOC quantification method for machine-generated, mainstream cigarette smoke using solidphase microextraction gas chromatography–mass spectrometry (SPME-GC–MS). This method was developed to simultaneously quantify a broad range of smoke VOCs (i.e., carbonyls and volatiles, which historically have been measured by separate assays) for large exposure assessment studies. Our approach collects and maintains vapor-phase smoke in a gas sampling bag, where it is homogenized with isotopically labeled analogue internal standards and sampled using gas-phase SPME. High throughput is achieved by SPME automation using a CTC Analytics platform and custom bag tray. This method has successfully quantified 22 structurally diverse VOCs (e.g., benzene and associated monoaromatics, aldehydes and ketones, furans, acrylonitrile, 1,3-butadiene, vinyl chloride, and nitromethane) in the microgram range in mainstream smoke from 1R5F and 3R4F research cigarettes smoked under ISO (Cambridge Filter or FTC) and Intense (Health Canada or Canadian Intense) conditions. Our results are comparable to previous studies with few exceptions. Method accuracy was evaluated with third-party reference samples (≤15% error). Short-term diffusion losses from the gas sampling bag were minimal, with a 10% decrease in absolute response after 24 h. For most analytes, research cigarette inter- and intrarun precisions were ≤20% relative standard deviation (RSD). This method provides an accurate and robust means to quantify VOCs in cigarette smoke spanning a range of yields that is sufficient to characterize smoke exposure estimates. PMID:24933649
Colt, J S
1998-01-01
Epidemiologic studies of the association between residential pesticide use and cancer risk require an assessment of past pesticide exposures. Pesticide levels in carpet dust are believed to reflect long-term pesticide use. Recent epidemiologic studies have found collection of dust samples using the high-volume surface sampler (HVS3) to be expensive and cumbersome. We compared the levels of pesticides and other compounds in dust obtained from subjects' personal used vacuum cleaner bags to that collected by the HVS3 to see if this simpler method could replace the HVS3 in epidemiologic research. We visited the homes of 15 subjects, took the used bags from their vacuums, and collected carpet dust samples with the HVS3. The samples were analyzed for 42 target compounds: 26 pesticides, 10 polycyclic aromatic hydrocarbons (PAHs), and six polychlorinated biphenyl (PCB) congeners using GC/MS in selected ion monitoring mode. The two methods agreed in detecting the presence of the target compounds between 80% and 100% of the time. Neither sampling method was consistently more sensitive. The median target compound concentrations were similar, and a paired t-test showed no significant differences. For many compounds, the concentrations of compounds in the HVS3 samples were higher than those in the used bag samples at the upper end of the concentration ranges. However, the Spearman rank correlation coefficients were 0.85 or higher for most compounds, indicating that homes would be ranked similarly using both methods. Overall, there appears to be no clear difference in the quality of the pesticide, PAH, or PCB concentration data for the two dust collection methods. Images Figure 1 PMID:9799187
Passon, S; Uthoff, S; Jäckle-Meyer, I
1998-01-01
Improvement of clinical outcome of dialysis therapy is a task for everybody working in a dialysis unit. Here we consider dialysis conditions such as choice of treatment parameters and composition of dialysis fluid which may influence clinical outcome of dialysis therapy. Providing 'adequate' dialysis is the aim of the daily work of a dialysis nurse. Haemodialysis parameters with potential impact on dialysis adequacy are discussed with respect to quantification and optimisation. Every year, each patient comes in contact with 20,000 I dialysis fluid during HD treatment. The composition of the fluid, its physical and microbiological quality and their impact on clinical outcome are considered. The function of PD fluid is different from that of an HD fluid thus additional aspects have to be considered regarding its composition. Information is given how the composition and biocompatibility of PD solutions impact the dialysis therapy and how individual patient needs are considered.
A simplified method to recover urinary vesicles for clinical applications, and sample banking.
Musante, Luca; Tataruch, Dorota; Gu, Dongfeng; Benito-Martin, Alberto; Calzaferri, Giulio; Aherne, Sinead; Holthofer, Harry
2014-12-23
Urinary extracellular vesicles provide a novel source for valuable biomarkers for kidney and urogenital diseases: Current isolation protocols include laborious, sequential centrifugation steps which hampers their widespread research and clinical use. Furthermore, large individual urine sample volumes or sizable target cohorts are to be processed (e.g. for biobanking), the storage capacity is an additional problem. Thus, alternative methods are necessary to overcome such limitations. We have developed a practical vesicle isolation technique to yield easily manageable sample volumes in an exceptionally cost efficient way to facilitate their full utilization in less privileged environments and maximize the benefit of biobanking. Urinary vesicles were isolated by hydrostatic dialysis with minimal interference of soluble proteins or vesicle loss. Large volumes of urine were concentrated up to 1/100 of original volume and the dialysis step allowed equalization of urine physico-chemical characteristics. Vesicle fractions were found suitable to any applications, including RNA analysis. In the yield, our hydrostatic filtration dialysis system outperforms the conventional ultracentrifugation-based methods and the labour intensive and potentially hazardous step of ultracentrifugations are eliminated. Likewise, the need for trained laboratory personnel and heavy initial investment is avoided. Thus, our method qualifies as a method for laboratories working with urinary vesicles and biobanking.
A Simplified Method to Recover Urinary Vesicles for Clinical Applications, and Sample Banking
Musante, Luca; Tataruch, Dorota; Gu, Dongfeng; Benito-Martin, Alberto; Calzaferri, Giulio; Aherne, Sinead; Holthofer, Harry
2014-01-01
Urinary extracellular vesicles provide a novel source for valuable biomarkers for kidney and urogenital diseases: Current isolation protocols include laborious, sequential centrifugation steps which hampers their widespread research and clinical use. Furthermore, large individual urine sample volumes or sizable target cohorts are to be processed (e.g. for biobanking), the storage capacity is an additional problem. Thus, alternative methods are necessary to overcome such limitations. We have developed a practical vesicle isolation technique to yield easily manageable sample volumes in an exceptionally cost efficient way to facilitate their full utilization in less privileged environments and maximize the benefit of biobanking. Urinary vesicles were isolated by hydrostatic dialysis with minimal interference of soluble proteins or vesicle loss. Large volumes of urine were concentrated up to 1/100 of original volume and the dialysis step allowed equalization of urine physico-chemical characteristics. Vesicle fractions were found suitable to any applications, including RNA analysis. In the yield, our hydrostatic filtration dialysis system outperforms the conventional ultracentrifugation-based methods and the labour intensive and potentially hazardous step of ultracentrifugations are eliminated. Likewise, the need for trained laboratory personnel and heavy initial investment is avoided. Thus, our method qualifies as a method for laboratories working with urinary vesicles and biobanking. PMID:25532487
Solomon, Deepak; Gupta, Nilesh; Mulla, Nihal S; Shukla, Snehal; Guerrero, Yadir A; Gupta, Vivek
2017-11-01
In the past few years, measurement of drug release from pharmaceutical dosage forms has been a focus of extensive research because the release profile obtained in vitro can give an indication of the drug's performance in vivo. Currently, there are no compendial in vitro release methods designed for liposomes owing to a range of experimental challenges, which has created a major hurdle for both development and regulatory acceptance of liposome-based drug products. In this paper, we review the current techniques that are most often used to assess in vitro drug release from liposomal products; these include the membrane diffusion techniques (dialysis, reverse dialysis, fractional dialysis, and microdialysis), the sample-and-separate approach, the in situ method, the continuous flow, and the modified United States Pharmacopeia methods (USP I and USP IV). We discuss the principles behind each of the methods and the criteria that assist in choosing the most appropriate method for studying drug release from a liposomal formulation. Also, we have included information concerning the current regulatory requirements for liposomal drug products in the United States and in Europe. In light of increasing costs of preclinical and clinical trials, applying a reliable in vitro release method could serve as a proxy to expensive in vivo bioavailability studies. Graphical Abstract Appropriate in-vitro drug release test from liposomal products is important to predict the in-vivo performance.
NASA Astrophysics Data System (ADS)
Popa, C.; Bratu, A. M.; Matei, C.; Cernat, R.; Popescu, A.; Dumitras, D. C.
2011-07-01
The hypothesis that blood, urine and other body fluids and tissues can be sampled and analyzed to produce clinical information for disease diagnosis or therapy monitoring is the basis of modern clinical diagnosis and medical practice. The analysis of breath air has major advantages because it is a non-invasive method, represents minimal risk to personnel collecting the samples and can be often sampled. Breath air samples from the human subjects were collected using aluminized bags from QuinTron and analyzed using the laser photoacoustic spectroscopy (LPAS) technique. LPAS is used to detect traces of ethylene in breath air resulting from lipid peroxidation in lung epithelium following the radiotherapy and also traces of ammonia from patients subjected to hemodialysis for treatment of renal failure. In the case of patients affected by cancer and treated by external radiotherapy, all measurements were done at 10P(14) CO2 laser line, where the ethylene absorption coefficient has the largest value (30.4 cm-1 atm-1), whereas for patients affected by renal failure and treated by standard dialysis, all measurements were performed at 9R(30) CO2 laser line, where the ammonia absorption coefficient has the maximum value of 57 cm-1 atm-1. The levels of ethylene and ammonia in exhaled air, from patients with cancer and renal failure, respectively, were measured and compared with breath air contents from healthy humans. Human gas biomarkers were measured at sub-ppb (parts per billion) concentration sensitivities. It has been demonstrated that LPAS technique will play an important role in the future of exhaled breath air analysis. The key attributes of this technique are sensitivity, selectivity, fast and real time response, as well as its simplicity.
Okur, Neslihan Üstündağ; Özdemir, Derya İlem; Kahyaoğlu, Şennur Görgülü; Şenyiğit, Zeynep Ay; Aşıkoğlu, Makbule; Genç, Lütfi; Karasulu, H Yeşim
2015-01-01
The object of the current study was to prepare novel microemulsion formulations of aprotinin for parenteral delivery and to compare in vitro characteristics and release behaviour of different Technetium-99m ((99m)Tc)-Aprotinin loaded microemulsion formulations. In addition, cytotoxicity of microemulsion formulation was evaluated with cell culture studies on human immortalized pancreatic duct epithelial-like cells. For this aim, firstly, pseudo-ternary phase diagrams were plotted to detect the formulation region and optimal microemulsions were characterized for their thermodynamic stability, conductivity, particle size, zeta potential, viscosity, pH and in vitro release properties. For in vitro release studies aprotinin was labelled with (99m)Tc and labelling efficiency, radiochemical purity and stability of the radiolabeled complex were determined by several chromatography techniques. Radiolabeling efficiency of (99m)Tc-Aprotinin was found over than 90% without any significant changes up to 6 hours after labelling at room temperature. After that, in vitro release studies of (99m)Tc-Aprotinin loaded microemulsions were performed with two different methods; dissolution from diffusion cells and dialysis bags. Both methods showed that release rate of (99m)Tc- Aprotinin from microemulsion could be controlled by microemulsion formulations. Drug release from the optimized microemulsion formulations was found lower compared to drug solution at the end of six hours. According to stability studies, the optimized formulation was found to be stable over a period of 12 months. Also, human immortalized pancreatic duct epithelial-like cells were used to evaluate the cytotoxicity of optimum formulation. Developed microemulsion did not reveal cytotoxicity. In conclusion the present study indicated that the M1-APT microemulsion is appropriate for intravenous application of aprotinin.
Effectiveness of the ZeroFly® storage bag fabric against stored-product insects
USDA-ARS?s Scientific Manuscript database
The ZeroFly® Storage Bag is a polypropylene bag (PP) which has deltamethrin incorporated in its fibers, and represents a novel approach to reducing stored-product insect pest-related postharvest losses. Fabric samples from ZeroFly bags, polypropylene (PP) bags, jute bags, malathion-treated PP bags, ...
Mine Planning for Asteroid Orebodies
NASA Astrophysics Data System (ADS)
Gertsch, L. S.; Gertsch, R. E.
2000-01-01
Given that an asteroid (or comet) has been determined to contain sufficient material of value to be potentially economic to exploit, a mining method must be selected and implemented. This paper discusses the engineering necessary to bring a mine online, and the opportunities and challenges inherent in asteroid mineral prospects. The very important step of orebody characterization is discussed elsewhere. The mining methods discussed here are based on enclosing the asteroid within a bag in some fashion, whether completely or partially. In general, asteroid mining methods based on bags will consist of the following steps. Not all will be required in every case, nor necessarily in this particular sequence. Some steps will be performed simultaneously. Their purpose is to extract the valuable material from the body of the asteroid in the most efficient, cost-effective manner possible. In approximate order of initiation, if not of conclusion, the steps are: 1. Tether anchoring to the asteroid. 2. Asteroid motion control. 3. Body/fragment restraint system placement. 4. Operations platform construction. 5. Bag construction. 6. Auxiliary and support equipment placement. 7. Mining operations. 8. Processing operations. 9. Product transport to markets.
Technical Note: The determination of enclosed water volume in large flexible-wall mesocosms "KOSMOS"
NASA Astrophysics Data System (ADS)
Czerny, J.; Schulz, K. G.; Krug, S. A.; Ludwig, A.; Riebesell, U.
2013-03-01
The volume of water enclosed inside flexible-wall mesocosm bags is hard to estimate using geometrical calculations and can be strongly variable among bags of the same dimensions. Here we present a method for precise water volume determination in mesocosms using salinity as a tracer. Knowledge of the precise volume of water enclosed allows establishment of exactly planned treatment concentrations and calculation of elemental budgets.
Nishizawa, M; Igari, K; Kudo, T; Toyofuku, T; Inoue, Y; Uetake, H
2017-09-01
Peripheral artery disease in dialysis cases is more prone to critical limb ischemia compared to non-dialysis cases, with a significantly high rate of major amputation of the lower limbs. Lesions are distributed on the more distal side in dialysis critical limb ischemia cases. The aim of this study was to investigate the usefulness of indocyanine green angiography to determine differences in the regional circulation in the foot between dialysis and non-dialysis patients. The subjects included 62 cases, among which 20 were dialysis patients and 42 were non-dialysis patients. We compared the indocyanine green angiography parameters for regions of interest in the dialysis and non-dialysis groups, which included the magnitude of intensity from indocyanine green onset to maximum intensity (Imax), the time from indocyanine green onset to maximum intensity (Tmax), the time elapsed from the fluorescence onset to half the maximum intensity (T1/2), and the time from maximum intensity to declining to 90% of the maximum intensity (Td90%). These indocyanine green angiography parameters were measured at region of interest 1 (the Chopart joint), region of interest 2 (the Lisfranc joint), and region of interest 3 (the distal region of the first metatarsal bone). In the comparison between the dialysis and non-dialysis groups, a significant difference was observed regarding Tmax, T1/2, and Td90%, especially in region of interest 3. In this study, we show that regional tissue perfusion is more deteriorated in dialysis patients compared with non-dialysis patients using indocyanine green angiography. Tmax, T1/2, and Td90% could be useful clinical parameters to compare ischemic severity of the lower limb between dialysis and non-dialysis patients.
Comparison of outcomes for veterans receiving dialysis care from VA and non-VA providers.
Wang, Virginia; Maciejewski, Matthew L; Patel, Uptal D; Stechuchak, Karen M; Hynes, Denise M; Weinberger, Morris
2013-01-18
Demand for dialysis treatment exceeds its supply within the Veterans Health Administration (VA), requiring VA to outsource dialysis care by purchasing private sector dialysis for veterans on a fee-for-service basis. It is unclear whether outcomes are similar for veterans receiving dialysis from VA versus non-VA providers. We assessed the extent of chronic dialysis treatment utilization and differences in all-cause hospitalizations and mortality between veterans receiving dialysis from VA versus VA-outsourced providers. We constructed a retrospective cohort of veterans in 2 VA regions who received chronic dialysis treatment financed by VA between January 2007 and December 2008. From VA administrative data, we identified veterans who received outpatient dialysis in (1) VA, (2) VA-outsourced settings, or (3) both ("dual") settings. In adjusted analyses, we used two-part and logistic regression to examine associations between dialysis setting and all-cause hospitalization and mortality one-year from veterans' baseline dialysis date. Of 1,388 veterans, 27% received dialysis exclusively in VA, 47% in VA-outsourced settings, and 25% in dual settings. Overall, half (48%) were hospitalized and 12% died. In adjusted analysis, veterans in VA-outsourced settings incurred fewer hospitalizations and shorter hospital stays than users of VA due to favorable selection. Dual-system dialysis patients had lower one-year mortality than veterans receiving VA dialysis. VA expenditures for "buying" outsourced dialysis are high and increasing relative to "making" dialysis treatment within its own system. Outcomes comparisons inform future make-or-buy decisions and suggest the need for VA to consider veterans' access to care, long-term VA savings, and optimal patient outcomes in its placement decisions for dialysis services.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinitt, C.A.M.; Wood, J.; Lee, S.S.
2010-08-01
Cell motility is important in maintaining tissue homeostasis, facilitating epithelial wound repair and in tumour formation and progression. The aim of this study was to determine whether BAG-1 isoforms regulate epidermal cell migration in in vitro models of wound healing. In the human epidermal cell line HaCaT, endogenous BAG-1 is primarily nuclear and increases with confluence. Both transient and stable p36-Bag-1 overexpression resulted in increased cellular cohesion. Stable transfection of either of the three human BAG-1 isoforms p36-Bag-1 (BAG-1S), p46-Bag-1 (BAG-1M) and p50-Bag-1 (BAG-1L) inhibited growth and wound closure in serum-containing medium. However, in response to hepatocyte growth factor (HGF)more » in serum-free medium, BAG-1S/M reduced communal motility and colony scattering, but BAG-1L did not. In the presence of HGF, p36-Bag-1 transfectants retained proliferative response to HGF with no change in ERK1/2 activation. However, the cells retained E-cadherin localisation at cell-cell junctions and exhibited pronounced cortical actin. Point mutations in the BAG domain showed that BAG-1 inhibition of motility is independent of its function as a chaperone regulator. These findings are the first to suggest that BAG-1 plays a role in regulating cell-cell adhesion and suggest an important function in epidermal cohesion.« less
Storage of Maize in Purdue Improved Crop Storage (PICS) Bags
2017-01-01
Interest in using hermetic technologies as a pest management solution for stored grain has risen in recent years. One hermetic approach, Purdue Improved Crop Storage (PICS) bags, has proven successful in controlling the postharvest pests of cowpea. This success encouraged farmers to use of PICS bags for storing other crops including maize. To assess whether maize can be safely stored in PICS bags without loss of quality, we carried out laboratory studies of maize grain infested with Sitophilus zeamais (Motshulsky) and stored in PICS triple bags or in woven polypropylene bags. Over an eight month observation period, temperatures in the bags correlated with ambient temperature for all treatments. Relative humidity inside PICS bags remained constant over this period despite the large changes that occurred in the surrounding environment. Relative humidity in the woven bags followed ambient humidity closely. PICS bags containing S. zeamais-infested grain saw a significant decline in oxygen compared to the other treatments. Grain moisture content declined in woven bags, but remained high in PICS bags. Seed germination was not significantly affected over the first six months in all treatments, but declined after eight months of storage when infested grain was held in woven bags. Relative damage was low across treatments and not significantly different between treatments. Overall, maize showed no signs of deterioration in PICS bags versus the woven bags and PICS bags were superior to woven bags in terms of specific metrics of grain quality. PMID:28072835
Exploring the Association between Macroeconomic Indicators and Dialysis Mortality
Stel, Vianda S.; Caskey, Fergus J.; Stengel, Benedicte; Elliott, Robert F.; Covic, Adrian; Geue, Claudia; Cusumano, Ana; MacLeod, Alison M.; Jager, Kitty J.
2012-01-01
Summary Background and objectives Mortality on dialysis varies greatly worldwide, with patient-level factors explaining only a small part of this variation. The aim of this study was to examine the association of national-level macroeconomic indicators with the mortality of incident dialysis populations and explore potential explanations through renal service indicators, incidence of dialysis, and characteristics of the dialysis population. Design, setting, participants, & measurements Aggregated unadjusted survival probabilities were obtained from 22 renal registries worldwide for patients starting dialysis in 2003–2005. General population age and health, macroeconomic indices, and renal service organization data were collected from secondary sources and questionnaires. Linear modeling with log–log transformation of the outcome variable was applied to establish factors associated with survival on dialysis. Results Two-year survival on dialysis ranged from 62.3% in Iceland to 89.8% in Romania. A higher gross domestic product per capita (hazard ratio=1.02 per 1000 US dollar increase), a higher percentage of gross domestic product spent on healthcare (1.10 per percent increase), and a higher intrinsic mortality of the dialysis population (i.e., general population-derived mortality risk of the dialysis population in that country standardized for age and sex; hazard ratio=1.04 per death per 10,000 person years) were associated with a higher mortality of the dialysis population. The incidence of dialysis and renal service indicators were not associated with mortality on dialysis. Conclusions Macroeconomic factors and the intrinsic mortality of the dialysis population are associated with international differences in the mortality on dialysis. Renal service organizational factors and incidence of dialysis seem less important. PMID:22837275
Exploring the association between macroeconomic indicators and dialysis mortality.
Kramer, Anneke; Stel, Vianda S; Caskey, Fergus J; Stengel, Benedicte; Elliott, Robert F; Covic, Adrian; Geue, Claudia; Cusumano, Ana; Macleod, Alison M; Jager, Kitty J
2012-10-01
Mortality on dialysis varies greatly worldwide, with patient-level factors explaining only a small part of this variation. The aim of this study was to examine the association of national-level macroeconomic indicators with the mortality of incident dialysis populations and explore potential explanations through renal service indicators, incidence of dialysis, and characteristics of the dialysis population. Aggregated unadjusted survival probabilities were obtained from 22 renal registries worldwide for patients starting dialysis in 2003-2005. General population age and health, macroeconomic indices, and renal service organization data were collected from secondary sources and questionnaires. Linear modeling with log-log transformation of the outcome variable was applied to establish factors associated with survival on dialysis. Two-year survival on dialysis ranged from 62.3% in Iceland to 89.8% in Romania. A higher gross domestic product per capita (hazard ratio=1.02 per 1000 US dollar increase), a higher percentage of gross domestic product spent on healthcare (1.10 per percent increase), and a higher intrinsic mortality of the dialysis population (i.e., general population-derived mortality risk of the dialysis population in that country standardized for age and sex; hazard ratio=1.04 per death per 10,000 person years) were associated with a higher mortality of the dialysis population. The incidence of dialysis and renal service indicators were not associated with mortality on dialysis. Macroeconomic factors and the intrinsic mortality of the dialysis population are associated with international differences in the mortality on dialysis. Renal service organizational factors and incidence of dialysis seem less important.
Carbon footprint of shopping (grocery) bags in China, Hong Kong and India
NASA Astrophysics Data System (ADS)
Muthu, Subramanian Senthilkannan; Li, Y.; Hu, J. Y.; Mok, P. Y.
2011-01-01
Carbon footprint has become a term often used by the media in recent days. The human carbon footprint is professed to be a very serious global threat and every nation is looking at the possible options to reduce it since its consequences are alarming. A carbon footprint is a measure of the impact of human activities on earth and in particular on the environment; more specifically it relates to climate change and to the total amount of greenhouse gases produced, measured in units of carbon dioxide emitted. Effort of individuals in minimizing the carbon footprint is vital to save our planet. This article reports a study of the carbon footprint of various types of shopping bags (plastic, paper, non-woven and woven) using life cycle impact assessment (LCIA) technique in two stages. The first stage (baseline study), comprised the study of the impact of different types of shopping bags in the manufacturing phase, without considering their usage and disposal phases (cradle to gate stage). The LCIA was accomplished by the IPCC 2007 method, developed by the Inter Panel on Climate Change in SIMAPRO 7.2. The GWP (Global Warming Potential) values calculated by the IPCC 2007 method for 100 years were considered as a directive to compare the carbon footprint made by the different types of shopping bags under consideration. The next stage was the study of the carbon footprint of these bags including their usage and disposal phases (cradle to grave stage) and the results derived were compared with the results derived from the baseline study, which is the major focus of this research work. The values for usage and end-of-life phases were obtained from the survey questionnaire performed amongst different user groups of shopping bags in China, Hong Kong and India. The results show that the impact of different types of shopping bags in terms of their carbon footprint potential is very high if no usage and disposal options were provided. When the carbon footprint values from different disposal options were compared, the carbon footprint values were lower in the case where a higher percentage of reuse is preferred to recycling and disposing to landfill. The results indicate that a higher percentage of reuse could significantly scale down the carbon footprint. Once the shopping bags reached the point where they can no longer be reused, they must be forwarded to recycling options, rather than being disposed to landfill. At this juncture, consumer's perceptions and behaviours in connection with the respective government's policies in promoting & facilitating recycling systems could be critical in reducing the carbon footprint of various shopping bags.
Screening and identification of per- and polyfluoroalkyl substances in microwave popcorn bags.
Zabaleta, Itsaso; Negreira, Noelia; Bizkarguenaga, Ekhine; Prieto, Ailette; Covaci, Adrian; Zuloaga, Olatz
2017-09-01
Liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (LC-QToF-MS) was used for the accurate identification (<10ppm) of different polyfluoroalkylphosphates (PAPs) and their intermediate and end degradation products in popcorn bags. Up to 46 per- and polyfluoroalkyl substances (PFASs) and precursors were identified. Moreover, an accurate method based on focused ultrasonic solid-liquid extraction (FUSLE) and a clean-up step with Envi-Carb sorbent was validated and applied to the quantification of 24 PFASs in popcorn bags from over twelve European countries, three American countries and two Asian countries. To the best of our knowledge, this is the first time that identification and quantification of some intermediates of PFAS precursors (different chain length fluorotelomer saturated acids (FTCAs) and fluorotelomer unsaturated acids (FTUCAs)) have been reported. Moreover, different patterns in the microwave popcorn bag composition were observed within the countries; while in European and American countries short chain PFASs were detected, Asian countries still use long chain PFASs. Copyright © 2017 Elsevier Ltd. All rights reserved.
de Almeida, Maurício Liberal; Saatkamp, Cassiano Junior; Fernandes, Adriana Barrinha; Pinheiro, Antonio Luiz Barbosa; Silveira, Landulfo
2016-09-01
Urea and creatinine are commonly used as biomarkers of renal function. Abnormal concentrations of these biomarkers are indicative of pathological processes such as renal failure. This study aimed to develop a model based on Raman spectroscopy to estimate the concentration values of urea and creatinine in human serum. Blood sera from 55 clinically normal subjects and 47 patients with chronic kidney disease undergoing dialysis were collected, and concentrations of urea and creatinine were determined by spectrophotometric methods. A Raman spectrum was obtained with a high-resolution dispersive Raman spectrometer (830 nm). A spectral model was developed based on partial least squares (PLS), where the concentrations of urea and creatinine were correlated with the Raman features. Principal components analysis (PCA) was used to discriminate dialysis patients from normal subjects. The PLS model showed r = 0.97 and r = 0.93 for urea and creatinine, respectively. The root mean square errors of cross-validation (RMSECV) for the model were 17.6 and 1.94 mg/dL, respectively. PCA showed high discrimination between dialysis and normality (95 % accuracy). The Raman technique was able to determine the concentrations with low error and to discriminate dialysis from normal subjects, consistent with a rapid and low-cost test.
Recovery of Agricultural Odors and Odorous Compounds from Polyvinyl Fluoride Film Bags
Parker, David B.; Perschbacher-Buser, Zena L.; Cole, N. Andy; Koziel, Jacek A.
2010-01-01
Accurate sampling methods are necessary when quantifying odor and volatile organic compound emissions at agricultural facilities. The commonly accepted methodology in the U.S. has been to collect odor samples in polyvinyl fluoride bags (PVF, brand name Tedlar®) and, subsequently, analyze with human panelists using dynamic triangular forced-choice olfactometry. The purpose of this research was to simultaneously quantify and compare recoveries of odor and odorous compounds from both commercial and homemade PVF sampling bags. A standard gas mixture consisting of p-cresol (40 μg m−3) and seven volatile fatty acids: acetic (2,311 μg m−3), propionic (15,800 μg m−3), isobutyric (1,686 μg m−3), butyric (1,049 μg m−3), isovaleric (1,236 μg m−3), valeric (643 μg m−3), and hexanoic (2,158 μg m−3) was placed in the PVF bags at times of 1 h, 1 d, 2 d, 3 d, and 7 d prior to compound and odor concentration analyses. Compound concentrations were quantified using sorbent tubes and gas chromatography/mass spectrometry. Odor concentration, intensity, and hedonic tone were measured using a panel of trained human subjects. Compound recoveries ranged from 2 to 40% after 1 h and 0 to 14% after 7 d. Between 1 h and 7 d, odor concentrations increased by 45% in commercial bags, and decreased by 39% in homemade bags. Minimal changes were observed in intensity and hedonic tone over the same time period. These results suggest that PVF bags can bias individual compound concentrations and odor as measured by dynamic triangular forced-choice olfactometry. PMID:22163671
49 CFR 178.520 - Standards for textile bags.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for a sift-proof textile bag; and (3) 5L3 for a water-resistant textile bag. (b) Construction... bag. (2) Bags, sift-proof, 5L2: The bag must be made sift-proof, by appropriate means, such as by the...
Unit-Dose Bags For Formulating Intravenous Solutions
NASA Technical Reports Server (NTRS)
Finley, Mike; Kipp, Jim; Scharf, Mike; Packard, Jeff; Owens, Jim
1993-01-01
Smaller unit-dose flowthrough bags devised for use with large-volume parenteral (LVP) bags in preparing sterile intravenous solutions. Premeasured amount of solute stored in such unit-dose bag flushed by predetermined amount of water into LVP bag. Relatively small number of LVP bags used in conjunction with smaller unit-dose bags to formulate large number of LVP intravenous solutions in nonsterile environment.
[Effects of bagging on the microenvironment, yield and quality of overwintering tomato].
Wang, Lei; Xu, Kun; Bei, Feng; Gao, Fang-Sheng
2007-04-01
Taking overwintering tomato variety "L402" as test material, this paper studied the effects of bagging with different texture bags on its fruit enlarging and quality, and the microenvironment within the bags. The results showed that bagging could change the microenvironment of fruit development, promote fruit maturing in advance, and improve fruit mass and quality. The light intensity and humidity in parchment bag were at the intermediate of those in plastic and no-spinning cloth bags, and the temperature was the highest among all treatments, except that it was lower than that in plastic bag at forenoon. The fruit enlarging rate in parchment bag was also the highest, and the single fruit mass increased by 15.34%, compared with the control. However, the fruit soluble solid, soluble sugar, and vitamine C contents and the sugar/acid ratio in all bagging treatments were lower than those of the control, suggesting that bagging debased the nutritive quality and the tastiness of tomato fruit. Due to the fact that bagging prevented the direct contact of fruit with pesticides, the fruit chlorpyrifos and betacypermethrin contents in parchment and plastic bags were lower than the control, except that the chlorpyrifos content in no-spinning cloth bag was higher.
Kawanishi, Hideki; Akiba, Takashi; Masakane, Ikuto; Tomo, Tadashi; Mineshima, Michio; Kawasaki, Tadayuki; Hirakata, Hideki; Akizawa, Tadao
2009-04-01
The Committee of Scientific Academy of the Japanese Society for Dialysis Therapy (JSDT) proposes a new standard on microbiological management of fluids for hemodialysis and related therapies. This standard is within the scope of the International Organization for Standardization (ISO), which is currently under revision. This standard is to be applied to the central dialysis fluid delivery systems (CDDS), which are widely used in Japan. In this standard, microbiological qualities for dialysis water and dialysis fluids are clearly defined by endotoxin level and bacterial count. The qualities of dialysis fluids were classified into three levels: standard, ultrapure, and online prepared substitution fluid. In addition, the therapeutic application of each dialysis fluid is clarified. Since high-performance dialyzers are frequently used in Japan, the standard recommends that ultrapure dialysis fluid be used for all dialysis modalities at all dialysis facilities. It also recommends that the dialysis equipment safety management committee at each facility should validate the microbiological qualities of online prepared substitution fluid.
Collins, Allan J; Foley, Robert N; Gilbertson, David T; Chen, Shu-Cheng
2015-06-01
The United States Renal Data System (USRDS) began in 1989 through US Congressional authorization under National Institutes of Health competitive contracting. Its history includes five contract periods, two of 5 years, two of 7.5 years, and the fifth, awarded in February 2014, of 5 years. Over these 25 years, USRDS reporting transitioned from basic incidence and prevalence of end-stage renal disease (ESRD), modalities, and overall survival, as well as focused special studies on dialysis, in the first two contract periods to a comprehensive assessment of aspects of care that affect morbidity and mortality in the second two periods. Beginning in 1999, the Minneapolis Medical Research Foundation investigative team transformed the USRDS into a total care reporting system including disease severity, hospitalizations, pediatric populations, prescription drug use, and chronic kidney disease and the transition to ESRD. Areas of focus included issues related to death rates in the first 4 months of treatment, sudden cardiac death, ischemic and valvular heart disease, congestive heart failure, atrial fibrillation, and infectious complications (particularly related to dialysis catheters) in hemodialysis and peritoneal dialysis patients; the burden of congestive heart failure and infectious complications in pediatric dialysis and transplant populations; and morbidity and access to care. The team documented a plateau and decline in incidence rates, a 28% decline in death rates since 2001, and changes under the 2011 Prospective Payment System with expanded bundled payments for each dialysis treatment. The team reported on Bayesian methods to calculate mortality ratios, which reduce the challenges of traditional methods, and introduced objectives under the Health People 2010 and 2020 national health care goals for kidney disease.
How have changes in front air bag designs affected frontal crash death rates? An update.
Teoh, Eric R
2014-01-01
Provide updated death rates comparing latest generations of frontal air bags in fatal crashes. Rates of driver and right-front passenger deaths in frontal crashes per 10 million registered vehicle years were compared using Poisson marginal structural models for passenger vehicles equipped with air bags certified as advanced and compliant (CAC), sled-certified air bags with advanced features, and sled-certified air bags without any advanced features. Analyses of driver death rates were disaggregated by age group, gender, and belt use. CAC air bags were associated with slightly elevated frontal crash death rates for both drivers and right-front passengers compared to sled-certified air bags with advanced features, but the differences were not statistically significant. Sled-certified air bags with advanced features were associated with significant benefits for drivers and for right-front passengers compared to sled-certified air bags without advanced features. CAC air bags were associated with a significant increase in belted driver death rate and a comparable but nonsignificant decrease in unbelted driver death rate compared to sled-certified air bags with advanced features. Sled-certified air bags with advanced features were associated with a nonsignificant 2 percent increase in belted driver death rate and a significant 26 percent decrease in unbelted driver death rate, relative to sled-certified air bags without advanced features. Implementing advanced features in sled-certified air bags was beneficial overall to drivers and right-front passengers with sled-certified air bags. No overall benefit was observed for CAC air bags compared to sled-certified air bags with advanced features. Further study is needed to understand the apparent reduction in belted driver protection observed for CAC air bags.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Pre-dialysis and post-dialysis examinations, or examinations that could have been furnished on a pre-dialysis or post-dialysis basis. (4) Insertion of catheters for patients who are on peritoneal dialysis and... laboratory test results, nurses' notes and any other medical documentation, as a basis for— (i) Adjustment of...
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Pre-dialysis and post-dialysis examinations, or examinations that could have been furnished on a pre-dialysis or post-dialysis basis. (4) Insertion of catheters for patients who are on peritoneal dialysis and... laboratory test results, nurses' notes and any other medical documentation, as a basis for— (i) Adjustment of...
BAG3 affects the nucleocytoplasmic shuttling of HSF1 upon heat stress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Young-Hee; Ahn, Sang-Gun; Kim, Soo-A., E-mail: ksooa@dongguk.ac.kr
2015-08-21
Bcl2-associated athoanogene (BAG) 3 is a member of the co-chaperone BAG family. It is induced by stressful stimuli such as heat shock and heavy metals, and it regulates cellular adaptive responses against stressful conditions. In this study, we identified a novel role for BAG3 in regulating the nuclear shuttling of HSF1 during heat stress. The expression level of BAG3 was induced by heat stress in HeLa cells. Interestingly, BAG3 rapidly translocalized to the nucleus upon heat stress. Immunoprecipitation assay showed that BAG3 interacts with HSF1 under normal and stressed conditions and co-translocalizes to the nucleus upon heat stress. We alsomore » demonstrated that BAG3 interacts with HSF1 via its BAG domain. Over-expression of BAG3 down-regulates the level of nuclear HSF1 by exporting it to the cytoplasm during the recovery period. Depletion of BAG3 using siRNA results in reduced nuclear HSF1 and decreased Hsp70 promoter activity. BAG3 in MEF(hsf1{sup −/−}) cells actively translocalizes to the nucleus upon heat stress suggesting that BAG3 plays a key role in the processing of the nucleocytoplasmic shuttling of HSF1 upon heat stress. - Highlights: • The expression level of BAG3 is induced by heat stress. • BAG3 translocates to the nucleus upon heat stress. • BAG3 interacts with HSF1 and co-localizes to the nucleus. • BAG3 is a key regulator for HSF1 nuclear shuttling.« less
49 CFR 178.520 - Standards for textile bags.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) 5L2 for a sift-proof textile bag; and (3) 5L3 for a water-resistant textile bag. (b) Construction... bag. (2) Bags, sift-proof, 5L2: The bag must be made sift-proof, by appropriate means, such as by the...
Breaking BAG: The Co-Chaperone BAG3 in Health and Disease.
Behl, Christian
2016-08-01
Human BAG (Bcl-2-associated athanogene) proteins form a family of antiapoptotic proteins that currently consists of six members (BAG1-6) all sharing the BAG protein domain from which the name arises. Via this domain, BAG proteins bind to the heat shock protein 70 (Hsp70), thereby acting as a co-chaperone regulating the activity of Hsp70. In addition to their antiapoptotic activity, all human BAG proteins have distinct functions in health and disease, and BAG3 in particular is the focus of many investigations. BAG3 has a modular protein domain composition offering the possibility for manifold interactions with other proteins. Various BAG3 functions are implicated in disorders including cancer, myopathies, and neurodegeneration. The discovery of its role in selective autophagy and the description of BAG3-mediated selective macroautophagy as an adaptive mechanism to maintain cellular homeostasis, under stress as well as during aging, make BAG3 a highly interesting target for future pharmacological interventions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Vrdoljak, Ivica; Panjkota Krbavčić, Ines; Bituh, Martina; Vrdoljak, Tea; Dujmić, Zoran
2015-05-01
To analyze how different thermal processing methods affect the protein, calcium, and phosphorus content of hospital food served to dialysis patients and to generate recommendations for preparing menus that optimize nutritional content while minimizing the risk of hyperphosphatemia. Standard Official Methods of Analysis (AOAC) methods were used to determine dry matter, protein, calcium, and phosphorus content in potatoes, fresh and frozen carrots, frozen green beans, chicken, beef and pork, frozen hake, pasta, and rice. These levels were determined both before and after boiling in water, steaming, stewing in oil or water, or roasting. Most of the thermal processing methods did not significantly reduce protein content. Boiling increased calcium content in all foodstuffs because of calcium absorption from the hard water. In contrast, stewing in oil containing a small amount of water decreased the calcium content of vegetables by 8% to 35% and of chicken meat by 12% to 40% on a dry weight basis. Some types of thermal processing significantly reduced the phosphorus content of the various foodstuffs, with levels decreasing by 27% to 43% for fresh and frozen vegetables, 10% to 49% for meat, 7% for pasta, and 22.8% for rice on a dry weight basis. On the basis of these results, we modified the thermal processing methods used to prepare a standard hospital menu for dialysis patients. Foodstuffs prepared according to the optimized menu were similar in protein content, higher in calcium, and significantly lower in phosphorus than foodstuffs prepared according to the standard menu. Boiling in water and stewing in oil containing some water significantly reduced phosphorus content without affecting protein content. Soaking meat in cold water for 1 h before thermal processing reduced phosphorus content even more. These results may help optimize the design of menus for dialysis patients. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Molnar, Amber O; Hiremath, Swapnil; Brown, Pierre A; Akbari, Ayub
2016-07-19
Many patients with kidney failure "crash" onto dialysis or initiate dialysis in an unplanned fashion. There are varying definitions, but essentially, a patient is labeled as having a crash dialysis start if he or she has little to no care by a nephrologist prior to starting dialysis. A patient is labeled as having an unplanned dialysis start when he or she starts dialysis with a catheter or during a hospitalization. Given the high prevalence and poor outcomes associated with crash and unplanned dialysis starts, it is important to establish a better understanding of patient risk factors. We will conduct a systematic review and meta-analysis with a focus on both crash and unplanned dialysis starts. The first objective will be to determine patient risk factors for crash and unplanned dialysis starts. Secondary objectives will be to determine the most common criteria used to define both crash and unplanned dialysis starts and to determine outcomes associated with crash and unplanned dialysis starts. We will search MEDLINE, EMBASE and Cochrane Library from inception to the present date for all studies that report the characteristics and outcomes of patients who have crash vs. non-crash dialysis starts or unplanned vs. planned dialysis starts. We will also extract from included studies the criteria used to define crash and unplanned dialysis starts. If there are any eligible randomized controlled trials, quality assessment will be performed using the Cochrane Risk of Bias Assessment Tool. Observational studies will be evaluated using the Newcastle-Ottawa Scale. Data will be pooled in meta-analysis if deemed appropriate. The results of this review will inform the design of strategies to help reduce the incidence of crash and unplanned dialysis starts. Prospero CRD42016032916.
Lukowsky, Lilia R.; Mehrotra, Rajnish; Kheifets, Leeka; Arah, Onyebuchi A.; Nissenson, Allen R.
2013-01-01
Summary Background and objectives There are conflicting research results about the survival differences between hemodialysis and peritoneal dialysis, especially during the first 2 years of dialysis treatment. Given the challenges of conducting randomized trials, differential rates of modality switch and transplantation, and time-varying confounding in cohort data during the first years of dialysis treatment, use of novel analytical techniques in observational cohorts can help examine the peritoneal dialysis versus hemodialysis survival discrepancy. Design, setting, participants, & measurements This study examined a cohort of incident dialysis patients who initiated dialysis in DaVita dialysis facilities between July of 2001 and June of 2004 and were followed for 24 months. This study used the causal modeling technique of marginal structural models to examine the survival differences between peritoneal dialysis and hemodialysis over the first 24 months, accounting for modality change, differential transplantation rates, and detailed time-varying laboratory measurements. Results On dialysis treatment day 90, there were 23,718 incident dialysis—22,360 hemodialysis and 1,358 peritoneal dialysis—patients. Incident peritoneal dialysis patients were younger, had fewer comorbidities, and were nine and three times more likely to switch dialysis modality and receive kidney transplantation over the 2-year period, respectively, compared with hemodialysis patients. In marginal structural models analyses, peritoneal dialysis was associated with persistently greater survival independent of the known confounders, including dialysis modality switch and transplant censorship (i.e., death hazard ratio of 0.52 [95% confidence limit 0.34–0.80]). Conclusions Peritoneal dialysis seems to be associated with 48% lower mortality than hemodialysis over the first 2 years of dialysis therapy independent of modality switches or differential transplantation rates. PMID:23307879
National Trends in Emergency Room Visits of Dialysis Patients for Adverse Drug Reactions.
Chan, Lili; Saha, Aparna; Poojary, Priti; Chauhan, Kinsuk; Naik, Nidhi; Coca, Steven; Garimella, Pranav S; Nadkarni, Girish N
2018-06-12
Various medications are cleared by the kidneys, therefore patients with impaired renal function, especially dialysis patients are at risk for adverse drug events (ADEs). There are limited studies on ADEs in maintenance dialysis patients. We utilized a nationally representative database, the Nationwide Emergency Department Sample, from 2008 to 2013, to compare emergency department (ED) visits for dialysis and propensity matched non-dialysis patients. Log binomial regression was used to calculate relative risk of hospital admission and logistic regression to calculate ORs for in-hospital mortality while adjusting for patient and hospital characteristics. While ED visits for ADEs decreased in both groups, they were over 10-fold higher in dialysis patients than non-dialysis patients (65.8-88.5 per 1,000 patients vs. 4.6-5.4 per 1,000 patients respectively, p < 0.001). The top medication category associated with ED visits for ADEs in dialysis patients is agents primarily affecting blood constituents, which has increased. After propensity matching, patient admission was higher in dialysis patients than non-dialysis patients, (88 vs. 76%, p < 0.001). Dialysis was associated with a 3% increase in risk of admission and 3 times the odds of in-hospital mortality (adjusted OR 3, 95% CI 2.7-2.3.3). ED visits for ADEs are substantially higher in dialysis patients than non-dialysis patients. In dialysis patients, ADEs associated with agents primarily affecting blood constituents are on the rise. ED visits for ADEs in dialysis patients have higher inpatient admissions and in-hospital mortality. Further studies are needed to identify and implement measures aimed at reducing ADEs in dialysis patients. © 2018 S. Karger AG, Basel.
Combes, Gill; Sein, Kim; Allen, Kerry
2017-11-23
Pre-dialysis education (PDE) is provided to thousands of patients every year, helping them decide which renal replacement therapy (RRT) to choose. However, its effectiveness is largely unknown, with relatively little previous research into patients' views about PDE, and no research into staff views. This study reports findings relevant to PDE from a larger mixed methods study, providing insights into what staff and patients think needs to improve. Semi-structured interviews in four hospitals with 96 clinical and managerial staff and 93 dialysis patients, exploring experiences of and views about PDE, and analysed using thematic framework analysis. Most patients found PDE helpful and staff valued its role in supporting patient decision-making. However, patients wanted to see teaching methods and materials improve and biases eliminated. Staff were less aware than patients of how informal staff-patient conversations can influence patients' treatment decision-making. Many staff felt ill equipped to talk about all treatment options in a balanced and unbiased way. Patient decision-making was found to be complex and patients' abilities to make treatment decisions were adversely affected in the pre-dialysis period by emotional distress. Suggested improvements to teaching methods and educational materials are in line with previous studies and current clinical guidelines. All staff, irrespective of their role, need to be trained about all treatment options so that informal conversations with patients are not biased. The study argues for a more individualised approach to PDE which is more like counselling than education and would demand a higher level of skill and training for specialist PDE staff. The study concludes that even if these improvements are made to PDE, not all patients will benefit, because some find decision-making in the pre-dialysis period too complex or are unable to engage with education due to illness or emotional distress. It is therefore recommended that pre-dialysis treatment decisions are temporary, and that PDE is replaced with on-going RRT education which provides opportunities for personalised education and on-going review of patients' treatment choices. Emotional support to help overcome the distress of the transition to end-stage renal disease will also be essential to ensure all patients can benefit from RRT education.
Object recognition in images via a factor graph model
NASA Astrophysics Data System (ADS)
He, Yong; Wang, Long; Wu, Zhaolin; Zhang, Haisu
2018-04-01
Object recognition in images suffered from huge search space and uncertain object profile. Recently, the Bag-of- Words methods are utilized to solve these problems, especially the 2-dimension CRF(Conditional Random Field) model. In this paper we suggest the method based on a general and flexible fact graph model, which can catch the long-range correlation in Bag-of-Words by constructing a network learning framework contrasted from lattice in CRF. Furthermore, we explore a parameter learning algorithm based on the gradient descent and Loopy Sum-Product algorithms for the factor graph model. Experimental results on Graz 02 dataset show that, the recognition performance of our method in precision and recall is better than a state-of-art method and the original CRF model, demonstrating the effectiveness of the proposed method.
Hoggan, Rita E.; Zuck, Larry D.; Cannon, W. Roger; ...
2016-05-26
A study of improved methods of processing fuel pellets was undertaken using ceria and zirconia/yttria/alumina as surrogates. Through proper granulation and vertical vibration (tapping) of the parts bag prior to dry bag isostatic pressing (DBIP), reproducibility of diameter profiles among multiple pellets of ceria was improved by almost an order of magnitude. Reproducibility of sintered pellets was sufficiently good to possibly avoid grinding. Deviation from the mean diameter along the length of multiple pellets, as well as, deviation from roundness, decreased after sintering. This is not generally observed with dry pressed pellets. Thus it is possible to machine to tolerancemore » before sintering if grinding is necessary.« less
Meyer, Harald J; Chansue, Nantarika; Monticelli, Fabio
2006-03-10
The tsunami catastrophe of December 2004 left more than 200,000 dead. Disaster victim identification (DVI) teams were presented with the unprecedented challenge of identifying thousands of mostly markedly putrefied and partially skeletised bodies. To this end, an adequate body tagging method is essential. Conventional body bag tagging in terms of writing on body bags and placing of tags inside body bags proved unsatisfactory and problem prone due to consequences of cold storage, formalin (formaldehyde) embalming and body numbers inside storage facilities. The placement of radio frequency identification device (RFID) microchips inside victim bodies provided a practical solution to problems of body tagging and attribution in the DVI setting encountered by the Austrian DVI team in Thailand in early 2005.
METHOD FOR SOLVENT-ISOSTATIC PRESSING
Archibald, P.B.
1962-09-18
This invention provides a method for producing densely compacted bodies having relatively large dimensions. The method comprises the addition of a small quantity of a suitable solvent to a powder which is to be compacted. The solvent- moistened powder is placed inside a flexible bag, and the bag is suspended in an isostatic press. The solvent is squeezed out of the powder by the isostatic pressure, and the resulting compacted body is recovered. The presence of the solvent markedly decreases the proportion of void space in the powder, thereby resulting in a denser, more homogeneous compact. Another effect of the solvent is that it allows the isostatic pressing operation to be conducted at substantially lower pressures than are conventionally employed. (AEC)
Schroeder, Susan A.; Fulton, David C.; Lawrence, Jeffrey S.; Cordts, Steven D.
2017-01-01
This study explored how factors, including the function of bag limits, agency trust, satisfaction, hunting participation, and demographics, related to opinions about duck bag limits. The results are from a survey of 2014 Minnesota resident waterfowl hunters. Analyses identified four dimensions of attitudes about functions of bag limits, including that they: (a) are descriptive in defining the acceptable number of ducks that can be bagged, (b) are injunctive in establishing how many ducks should be allowed to be bagged, (c) ensure fair opportunities for all hunters to bag ducks, and (d) reflect biological limitations to protect waterfowl populations. Descriptive and fairness functions of bag limits were related to opinions about bag limits, as were factors related to agency trust, satisfaction, ducks bagged, experience with more restrictive bag limits, hunter age, and hunting group membership. Agencies may increase support by building trust and emphasizing the descriptive and fairness functions of regulations.
NASA Astrophysics Data System (ADS)
Stewart, R. D.; Abou Najm, M. R.; Rupp, D. E.; Selker, J. S.
2010-12-01
Shrinking/swelling soils are characterized by transient crack networks which function as dominant controls on the partitioning of surface and subsurface flow, the rate and depth of percolation, and evaporation rates. For such soils, understanding the dynamics of cracks is critical to accurately quantify their influence on groundwater recharge, stream-flow generation, and solute transport, among other component of a site’s hydrology. We propose a low-cost method for measuring transient crack-volume using a sealed plastic bag connected by a hose to a PVC standpipe. The empty bag is placed into the crack, and then water is added via the standpipe, until the bag has expanded to the boundaries of the crack and some water remains in the standpipe. As the crack shrinks or swells, its volume changes, causing water displacement within the bag, which is measured as a corresponding change in water level in the standpipe. An automated level logger within the standpipe is used to record changes in water level, which are converted to volumetric changes from the known internal cross-sectional area of the standpipe. The volume of water filling the bag is accurately measured at the start and completion of the experiment (to check for leakage). Adding the startup volume to the cumulative temporal volumetric change in the standpipe provides a simple and accurate method for monitoring transient crack volume. Currently, the design is undergoing preliminary testing in a field site in Ninhue, Chile, and field and laboratory testing in Corvallis, Oregon. Initial results from the Chilean field site suggest that the crack-o-meters are responding to the closing of cracks, but further effort is needed to calibrate and validate the results. We hope that these low-cost “crack-o-meters” will become useful and simple tools for researchers to quantify temporal changes in crack volume with the objective of incorporating these results into hydrological modeling efforts.
Administration of chemotherapy in patients on dialysis.
Kuo, James C; Craft, Paul S
2015-08-01
The prevalence of patients on dialysis has increased and these patients present a challenge for chemotherapy administration when diagnosed with cancer. A consensus on the dosage and timing of different chemotherapeutic agents in relation to dialysis has not been established. We describe the pattern of care and treatment outcome for cancer patients on dialysis in our institution. The dataset from the Australia and New Zealand Dialysis and Transplant Registry of patients on dialysis who had a diagnosis of cancer was obtained and matched to the pharmacy records in our institution to identify patients who had received chemotherapy while on dialysis. Relevant clinical information including details of the dialysis regimen, chemotherapy administration and adverse events was extracted for analysis. Between July 1999 and July 2014, 21 patients on dialysis were included for analysis. Five (23.8%) received chemotherapy, most of which was administered before dialysis sessions. As a result of adverse events, one patient discontinued treatment; two other patients required dose reduction or treatment delay. Chemotherapy administration was feasible in cancer patients on dialysis, but chemotherapy usage was low. Better understanding of the altered pharmacokinetics in patients on dialysis may improve chemotherapy access and practice.
Choice of modality with the use of high-performance membrane and evaluation for clinical effects.
Masakane, Ikuto
2011-01-01
The golden target for dialysis therapy should be to guarantee longer survival and to give a higher quality of life without dialysis-related complications. In order to achieve this target, the choice of dialysis modality and membrane is essential but we have not yet established what the best choice for a dialysis modality and membrane are. Generally, we choose a dialysis modality for better solute removal and better biocompatibility. In this issue we would like to propose that the patients' preference for dialysis therapy is a useful parameter in prescribing the dialysis modality. In our recent experience, chronic dialysis patients have had preferences on a dialysis modality and membrane, those being PMMA, EVAL, AN-69 and pre-dilution online HDF. These modalities could relieve them of uncomfortable dialysis-related symptoms such as insomnia, itchiness, irritability, and so on. Other characteristics of these modalities are of a nutritional advantage, a broad removal pattern of uremic toxins including low-molecular-weight protein and protein-bound uremic toxins, and good biocompatibility free from chemical components of dialysis membrane. In conclusion, patients' symptoms could be a useful parameter to choose a dialysis modality and membrane. Copyright © 2011 S. Karger AG, Basel.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
...; cable clamps; locks; belts; O-rings; sealing gaskets; support packages; filter bags; disposable bags; assembly bags; dust bags; maintenance packs; paper bags; dirt tube kits; paper adaptor bags; filters...; wire racks; bake pans; pizza pans; coffee water filters; water filters; base assemblies; dust cup...
WW domain of BAG3 is required for the induction of autophagy in glioma cells.
Merabova, Nana; Sariyer, Ilker Kudret; Saribas, A Sami; Knezevic, Tijana; Gordon, Jennifer; Turco, M Caterina; Rosati, Alessandra; Weaver, Michael; Landry, Jacques; Khalili, Kamel
2015-04-01
Autophagy is an evolutionarily conserved, selective degradation pathway of cellular components that is important for cell homeostasis under healthy and pathologic conditions. Here we demonstrate that an increase in the level of BAG3 results in stimulation of autophagy in glioblastoma cells. BAG3 is a member of a co-chaperone family of proteins that associates with Hsp70 through a conserved BAG domain positioned near the C-terminus of the protein. Expression of BAG3 is induced by a variety of environmental changes that cause stress to cells. Our results show that BAG3 overexpression induces autophagy in glioma cells. Interestingly, inhibition of the proteasome caused an increase in BAG3 levels and induced autophagy. Further analysis using specific siRNA against BAG3 suggests that autophagic activation due to proteosomal inhibition is mediated by BAG3. Analyses of BAG3 domain mutants suggest that the WW domain of BAG3 is crucial for the induction of autophagy. BAG3 overexpression also increased the interaction between Bcl2 and Beclin-1, instead of disrupting them, suggesting that BAG3 induced autophagy is Beclin-1 independent. These observations reveal a novel role for the WW domain of BAG3 in the regulation of autophagy. © 2014 Wiley Periodicals, Inc.
WW domain of BAG3 is required for the induction of autophagy in glioma cells
Merabova, Nana; Sariyer, Ilker Kudret; Saribas, A Sami; Knezevic, Tijana; Gordon, Jennifer; Weaver, Michael; Landry, Jacques; Khalili, Kamel
2015-01-01
Autophagy is an evolutionarily conserved, selective degradation pathway of cellular components that is important for cell homeostasis under healthy and pathologic conditions. Here we demonstrate that an increase in the level of BAG3 results in stimulation of autophagy in glioblastoma cells. BAG3 is a member of a co-chaperone family of proteins that associate with Hsp70 through a conserved BAG domain positioned near the C-terminus of the protein. Expression of BAG3 is induced by a variety of environmental changes that cause stress to cells. Our results show that BAG3 overexpression induces autophagy in glioma cells. Interestingly, inhibition of the proteasome caused an increase in BAG3 levels and induced autophagy. Further analysis using specific siRNA against BAG3 suggests that autophagic activation due to proteosomal inhibition is mediated by BAG3. Analyses of BAG3 domain mutants suggest that the WW domain of BAG3 is crucial for the induction of autophagy. BAG3 overexpression also increased the interaction between Bcl2 and Beclin-1, instead of disrupting them, suggesting that BAG3 induced autophagy is Beclin-1 independent. These observations reveal a novel role for the WW domain of BAG3 in the regulation of autophagy. PMID:25204229
Evaluation of an alternative extraction procedure for enterotoxin determination in dairy products.
Meyrand, A; Atrache, V; Bavai, C; Montet, M P; Vernozy-Rozand, C
1999-06-01
A concentration protocol based on trichloroacetic acid precipitation was evaluated and compared with the reference method using dialysis concentration. Different quantities of purified staphylococcal enterotoxins were added to pasteurized Camembert-type cheeses. Detection of enterotoxins in these cheeses was performed using an automated detection system. Raw goat milk Camembert-type cheeses involved in a staphylococcal food poisoning were also tested. Both enterotoxin extraction methods allowed detection of the lowest enterotoxin concentration level used in this study (0.5 ng g-1). Compared with the dialysis concentration method, TCA precipitation of staphylococcal enterotoxins was 'user-friendly' and less time-consuming. These results suggest that TCA precipitation is a rapid (1 h), simple and reliable method of extracting enterotoxin from food which gives excellent recovery from dairy products.
Likelihood of Starting Dialysis after Incident Fistula Creation
Quinn, Robert R.; Garg, Amit X.; Kim, S. Joseph; Wald, Ron; Paterson, J. Michael
2012-01-01
Summary Background and objectives Guidelines promote early fistula creation to avoid central venous catheter use. This practice may lead to fistula creations in patients who never receive dialysis. The objective of this study was to estimate the risk of fistula nonuse with long-term follow-up. Design, setting, participants, & measurements Administrative health data identified 1929 predialysis adults who had their first fistula creation between April of 2002 and March of 2006. Patients were followed for a minimum of 2 years or until they began dialysis, received a kidney transplant, or died. Results The median follow-up times in patients who started dialysis, died without receiving dialysis, and remained in predialysis were 6.1, 11.5, and 38.7 months, respectively. Eighty-one percent of patients initiated dialysis; 9% of patients died without receiving dialysis, and 10% of patients remained predialysis. Forty percent of patients had their first fistula creation 3–12 months before initiating dialysis (the recommended window). Thirty percent were created within 90 days of starting dialysis; 30% were created more than 1 year before starting dialysis, and 10% were created more than 2 years before starting dialysis. Older patients, females, and patients with less comorbidity were not as likely to initiate dialysis after incident fistula creation. Conclusions Most patients who underwent fistula creation before starting dialysis eventually received dialysis with extended follow-up, but the risk was significantly modified by age, sex, and comorbidity. Many patients had fistula creations earlier or later than recommended. PMID:22344512
Ku, Ho Suk; Kim, Sungho; Kim, HyeHyeon; Chung, Hee-Joon; Park, Yu Rang; Kim, Ju Han
2014-04-01
Health Avatar Beans was for the management of chronic kidney disease and end-stage renal disease (ESRD). This article is about the DialysisNet system in Health Avatar Beans for the seamless management of ESRD based on the personal health record. For hemodialysis data modeling, we identified common data elements for hemodialysis information (CDEHI). We used ASTM continuity of care record (CCR) and ISO/IEC 11179 for the compliance method with a standard model for the CDEHI. According to the contents of the ASTM CCR, we mapped the CDHEI to the contents and created the metadata from that. It was transformed and parsed into the database and verified according to the ASTM CCR/XML schema definition (XSD). DialysisNet was created as an iPad application. The contents of the CDEHI were categorized for effective management. For the evaluation of information transfer, we used CarePlatform, which was developed for data access. The metadata of CDEHI in DialysisNet was exchanged by the CarePlatform with semantic interoperability. The CDEHI was separated into a content list for individual patient data, a contents list for hemodialysis center data, consultation and transfer form, and clinical decision support data. After matching to the CCR, the CDEHI was transformed to metadata, and it was transformed to XML and proven according to the ASTM CCR/XSD. DialysisNet has specific consideration of visualization, graphics, images, statistics, and database. We created the DialysisNet application, which can integrate and manage data sources for hemodialysis information based on CCR standards.
Cao, Fang; Li, Lanfei; Lin, Miao; Lin, Qinyu; Ruan, Yiping; Hong, Fuyuan
2018-04-20
This study aims to investigate the application value of Internet-based instant messaging software in the follow-up of patients using peritoneal dialysis. Peritoneal dialysis is an effective renal replacement treatment for end-stage renal disease. The clinical usefulness of Internet-based instant messaging software in the follow-up of peritoneal dialysis patients, including the incidence of peritonitis and exit-site infection, the levels of albumin and electrolytes and the degree of patients' satisfaction, remains unknown. Between January 2009-April 2016, a total of 160 patients underwent continuous peritoneal dialysis in the Department of Nephrology, Fujian Provincial Hospital were invited to participate voluntarily in this study. The patients were randomly assigned to the instant messenger (QQ) follow-up group (n = 80) and the traditional follow-up group (n = 80). The differences in death, hospitalisation, peritonitis, exit-site infection, and patients' satisfaction were investigated during 1 year of follow-up. The mean follow-up duration is 11.4 ± 1.5 months. Compared with the patients in the traditional follow-up group, patients in the QQ follow-up group showed higher levels of serum albumin (p = .009) and haemoglobin (p = .009), lower levels of phosphorus (p < .001) and calcium-phosphorus product (p = .001), and better degree of satisfaction (p < .001). Internet-based follow-up by instant messaging software appears to be a feasible and acceptable method of delivering peritoneal dialysis treatment for patients with end-stage renal disease. © 2018 John Wiley & Sons Ltd.
Which echocardiographic parameter is a better marker of volume status in hemodialysis patients?
Sabaghian, Tahereh; Hajibaratali, Bahareh; Samavat, Shiva
2016-11-01
Bio-impedance analysis (BIA) is a preferred method for estimating the volume status. However, it cannot be utilized in daily practice. Since the assessment of the volume status is important and challenging for hemodialysis (HD) patients, the aim of study was to determine the volume status in chronic HD patients using echocardiographic parameters and assess its correlation with BIA. In this cross-sectional analysis, echocardiography and BIA were performed on 30 chronic HD patients 30 min before and 30 min after dialysis. All the cases of dialysis were performed in the middle of the week. This study also assessed the correlation between echocardiographic parameters and BIA parameters. There were significant differences between ECW, TBW, and TBW% (TBW/W) before and after HD. Significant differences were observed between echocardiographic parameters of IVCD, IVCDi min , IVCDi max before and after the HD. LVEDD, LVESD, LA area, mitral valve inflow, E/E', and IVRT, were improved after dialysis, too. There was a significant correlation between IVCDi min as an index of volume status, ECW% and TBW% before HD and IVCDi min change after dialysis had a significant correlation with %ECW change after dialysis. Comparison between hypertensive and non-hypertensive groups indicated IVCDi min was significantly lower in non-hypertensive group after dialysis. Our results showed a correlation between IVCDi min and BIA parameters before HD. So, it seems that IVCDi min can be a good parameter for determining the volume status of HD patients. However, further studies, with larger sample size and with a prospective study design, are required to confirm these results.
Yang, Song-Yi; Kim, Seong-Hwan; Choi, Se-Young; Kim, Kwang-Mahn
2016-02-24
The objective of the study was to compare the acid neutralizing ability and shear bond strength (SBS) of three different types of orthodontic adhesives containing bioactive glasses (BAGs). 45S5, 45S5F and S53P4 BAGs were prepared using the melting technique and ground to fine particles. Orthodontic adhesives containing three types of BAGs were prepared as follows: 52.5% 45S5 BAG + 17.5% glass (45S5_A); 61.25% 45S5 BAG + 8.75% glass (45S5_B); 52.5% 45S5F BAG + 17.5% glass (45S5F_A); 61.25% 45S5F BAG + 8.75% glass (45S5F_B); 52.5% S53P4 BAG + 17.5% glass (S53P4_A); 61.25% S53P4 BAG + 8.75% glass (S53P4_B); and 70.0% glass (BAG_0). To evaluate the acid neutralizing properties, specimens were immersed in lactic acid solution, and pH changes were measured. SBS was measured with a universal testing machine. For all of the BAG-containing adhesives, the one with 61.25% of BAG showed a significantly greater increase of pH than the one with 52.5% of BAG ( p < 0.05). Groups with 61.25% of BAG showed lower SBS than samples with 52.5% of BAG. 45S5F_A showed no significant difference of SBS compared to BAG_0 ( p > 0.05). The adhesive containing 61.25% of 45S5F BAG exhibited clinically acceptable SBS and acid neutralizing properties. Therefore, this composition is a suitable candidate to prevent white spot lesions during orthodontic treatment.
1995-09-12
DCAM, developed by MSFC, grows crystals by the dialysis and liquid-liquid diffusion methods. In both methods, protein crystal growth is induced by changing conditions in the protein. In dialysis, a semipermeable membrane retains the protein solution in one compartment, while allowing molecules of precipitant to pass freely through the membrane from an adjacent compartment. As the precipitant concentration increases within the protein compartment, crystallization begins. In liquid-liquid diffusion, a protein solution and a precipitant solution are layered in a container and allowed to diffuse into each other. This leads to conditions which may induce crystallization of the protein. Liquid-liquid diffusion is difficult on Earth because density and temperature differences cause the solutions to mix rapidly.
Schaefer, Franz; Borzych-Duzalka, Dagmara; Azocar, Marta; Munarriz, Reyner Loza; Sever, Lale; Aksu, Nejat; Barbosa, Lorena Sànchez; Galan, Yajaira Silva; Xu, Hong; Coccia, Paula A.; Szabo, Attila; Wong, William; Salim, Rosana; Vidal, Enrico; Pottoore, Stephen; Warady, Bradley A.
2012-01-01
♦ Background, Objectives, and Methods: The number of patients on chronic peritoneal dialysis (CPD) is increasing rapidly on a global scale. We analyzed the International Pediatric Peritoneal Dialysis Network (IPPN) registry, a global database active in 33 countries spanning a wide range in gross national income (GNI), to identify the impact of economic conditions on CPD practices and outcomes in children and adolescents. ♦ Results: We observed close associations of GNI with the fraction of very young patients on dialysis, the presence and number of comorbidities, the prevalence of patients with unexplained causes of end-stage kidney disease, and the rate of culture-negative peritonitis. The prevalence of automated PD increased with GNI, but was 46% even in the lowest GNI stratum. The GNI stratum also affected the use of biocompatible peritoneal dialysis fluids, enteral tube feeding, calcium-free phosphate binders, active vitamin D analogs, and erythropoiesis-stimulating agents (ESAs). Patient mortality was strongly affected by GNI (hazard ratio per $10 000: 3.3; 95% confidence interval: 2.0 to 5.5) independently of young patient age and the number of comorbidities present. Patients from low-income countries tended to die more often from infections unrelated to CPD (5 of 9 vs 15 of 61, p = 0.1). The GNI was also a strong independent predictor of standardized height (p < 0.0001), adding to the impact of congenital renal disease, anuria, age at PD start, and dialysis vintage. Patients from the lower economic strata (GNI < $18 000) had higher serum parathyroid hormone (PTH) and lower serum calcium, and achieved lower hemoglobin concentrations. No impact of GNI was observed with regard to CPD technique survival or peritonitis incidence. ♦ Conclusions: We conclude that CPD is practiced successfully, albeit with major regional variation related to economic differences, in children around the globe. The variations encompass the acceptance of very young patients and those with associated comorbidities to chronic dialysis programs, the use of automated PD and expensive drugs, and the diagnostic management of peritonitis. These variations in practice related to economic difference do not appear to affect PD technique survival; however, economic conditions seem to affect mortality on dialysis and standardized height, a marker of global child morbidity. PMID:22859840
Schaefer, Franz; Borzych-Duzalka, Dagmara; Azocar, Marta; Munarriz, Reyner Loza; Sever, Lale; Aksu, Nejat; Barbosa, Lorena Sànchez; Galan, Yajaira Silva; Xu, Hong; Coccia, Paula A; Szabo, Attila; Wong, William; Salim, Rosana; Vidal, Enrico; Pottoore, Stephen; Warady, Bradley A
2012-01-01
BACKGROUND, OBJECTIVES, AND METHODS: The number of patients on chronic peritoneal dialysis (CPD) is increasing rapidly on a global scale. We analyzed the International Pediatric Peritoneal Dialysis Network (IPPN) registry, a global database active in 33 countries spanning a wide range in gross national income (GNI), to identify the impact of economic conditions on CPD practices and outcomes in children and adolescents. We observed close associations of GNI with the fraction of very young patients on dialysis, the presence and number of comorbidities, the prevalence of patients with unexplained causes of end-stage kidney disease, and the rate of culture-negative peritonitis. The prevalence of automated PD increased with GNI, but was 46% even in the lowest GNI stratum. The GNI stratum also affected the use of biocompatible peritoneal dialysis fluids, enteral tube feeding, calcium-free phosphate binders, active vitamin D analogs, and erythropoiesis-stimulating agents (ESAs). Patient mortality was strongly affected by GNI (hazard ratio per $10 000: 3.3; 95% confidence interval: 2.0 to 5.5) independently of young patient age and the number of comorbidities present. Patients from low-income countries tended to die more often from infections unrelated to CPD (5 of 9 vs 15 of 61, p = 0.1). The GNI was also a strong independent predictor of standardized height (p < 0.0001), adding to the impact of congenital renal disease, anuria, age at PD start, and dialysis vintage. Patients from the lower economic strata (GNI < $18 000) had higher serum parathyroid hormone (PTH) and lower serum calcium, and achieved lower hemoglobin concentrations. No impact of GNI was observed with regard to CPD technique survival or peritonitis incidence. We conclude that CPD is practiced successfully, albeit with major regional variation related to economic differences, in children around the globe. The variations encompass the acceptance of very young patients and those with associated comorbidities to chronic dialysis programs, the use of automated PD and expensive drugs, and the diagnostic management of peritonitis. These variations in practice related to economic difference do not appear to affect PD technique survival; however, economic conditions seem to affect mortality on dialysis and standardized height, a marker of global child morbidity.
Three insulation methods to minimize intravenous fluid administration set heat loss.
Piek, Richardt; Stein, Christopher
2013-01-01
To assess the effect of three methods for insulating an intravenous (IV) fluid administration set on the temperature of warmed fluid delivered rapidly in a cold environment. The three chosen techniques for insulation of the IV fluid administration set involved enclosing the tubing of the set in 1) a cotton conforming bandage, 2) a reflective emergency blanket, and 3) a combination of technique 2 followed by technique 1. Intravenous fluid warmed to 44°C was infused through a 20-drop/mL 180-cm-long fluid administration set in a controlled environmental temperature of 5°C. Temperatures in the IV fluid bag, the distal end of the fluid administration set, and the environment were continuously measured with resistance thermosensors. Twenty repetitions were performed in four conditions, namely, a control condition (with no insulation) and the three different insulation methods described above. One-way analysis of variance was used to assess the mean difference in temperature between the IV fluid bag and the distal fluid administration set under the four conditions. In the control condition, a mean of 5.28°C was lost between the IV fluid bag and the distal end of the fluid administration set. There was a significant difference found between the four conditions (p < 0.001). A mean of 3.53°C was lost between the IV fluid bag and the distal end of the fluid administration set for both the bandage and reflective emergency blanket, and a mean of 3.06°C was lost when the two methods were combined. Using inexpensive and readily available materials to insulate a fluid administration set can result in a reduction of heat loss in rapidly infused, warmed IV fluid in a cold environment.
Piccoli, Giorgina Barbara; Guzzo, Gabriella; Vigotti, Federica Neve; Capizzi, Irene; Clari, Roberta; Scognamiglio, Stefania; Consiglio, Valentina; Aroasio, Emiliano; Gonella, Silvana; Veltri, Andrea; Avagnina, Paolo
2014-07-01
Renal function recovery (RFR), defined as the discontinuation of dialysis after 3 months of replacement therapy, is reported in about 1% of chronic dialysis patients. The role of personalized, intensive dialysis schedules and of resuming low-protein diets has not been studied to date. This report describes three patients with RFR who were recently treated at a new dialysis unit set up to offer intensive hemodialysis. All three patients were females, aged 73, 75, and 78 years. Kidney disease included vascular-cholesterol emboli, diabetic nephropathy and vascular and dysmetabolic disease. At time of RFR, the patients had been dialysis-dependent from 3 months to 1 year. Dialysis was started with different schedules and was progressively discontinued with a "decremental" policy, progressively decreasing number and duration of the sessions. A moderately restricted low-protein diet (proteins 0.6 g/kg/day) was started immediately after dialysis discontinuation. The most recent update showed that two patients are well off dialysis for 5 and 6 months; the diabetic patient died (sudden death) 3 months after dialysis discontinuation. Within the limits of small numbers, our case series may suggest a role for personalized dialysis treatments and for including low-protein diets in the therapy, in enhancing long-term RFR in elderly dialysis patients. © 2014 International Society for Hemodialysis.
Timing of dialysis initiation in transplant-naive and failed transplant patients
Molnar, Miklos Z.; Ojo, Akinlolu O.; Bunnapradist, Suphamai; Kovesdy, Csaba P.; Kalantar-Zadeh, Kamyar
2017-01-01
Over the past two decades, most guidelines have advocated early dialysis initiation on the basis of studies showing improved survival in patients starting dialysis early. These recommendations led to an increase in the proportion of patients initiating dialysis with an estimated glomerular filtration rate (eGFR) >10 ml/min/1.73 m2, from 20% in 1996 to 52% in 2008. During this period, patients starting dialysis with an eGFR ≥15 ml/min/1.73 m2 increased from 4% to 17%. However, recent studies have failed to substantiate a benefit of early dialysis initiation and some data have suggested worse outcomes in patients starting dialysis with a higher eGFR. Several reasons for this seemingly paradoxical observation have been suggested, including the fact that patients requiring early dialysis are likely to have more severe symptoms and comorbidities, leading to confounding by indication, as well as biological mechanisms that causally relate early dialysis therapy to adverse outcomes. Dialysis reinitiation in patients with a failing renal allograft encounters similar problems. However, unique factors associated with a failed allograft means that the optimal timing of dialysis initiation in failed transplant patients might differ from that in transplant-naive patients. In this Review, we will discuss studies of dialysis initiation and compare risks and benefits of early versus late dialysis therapy. PMID:22371250
Australian consumer perspectives on dialysis: first national census.
Ludlow, Marie J; Lauder, Lydia A; Mathew, Timothy H; Hawley, Carmel M; Fortnum, Debbie
2012-11-01
The percentage of people in Australia who undertake home dialysis has steadily decreased over the past 40 years and varies within Australia. Consumer factors related to this decline have not previously been determined. A 78-question survey was developed and piloted in 2008 and 2009. Survey forms were distributed to all adult routine dialysis patients in all Australian states and territories (except Northern Territory) between 2009 and 2010. Of 9223 distributed surveys, 3250 were completed and returned. 49% of respondents indicated they had no choice in the type of dialysis and 48% had no choice in dialysis location. Respondents were twice as likely to receive information about haemodialysis (85%) than APD (39%) or CAPD (41%). The provision of education regarding home modalities differed significantly between states, and decreased with increasing patient age. Additional nursing support and reimbursement of expenses increased the proportion of those willing to commence dialysis at home, from 13% to 34%. State differences in the willingness to consider home dialysis, the degree of choice in dialysis location, the desire to change current dialysis type and/or location, and the provision of information about dialysis were identified. The delivery of pre-dialysis education is variable, and does not support all options of dialysis for all individuals. State variances indicate that local policy and health professional teams significantly influence the operation of dialysis programs. © 2012 The Authors. Nephrology © 2012 Asian Pacific Society of Nephrology.
BAG3 induces the sequestration of proteasomal clients into cytoplasmic puncta
Minoia, Melania; Boncoraglio, Alessandra; Vinet, Jonathan; Morelli, Federica F; Brunsting, Jeanette F; Poletti, Angelo; Krom, Sabine; Reits, Eric; Kampinga, Harm H; Carra, Serena
2014-01-01
Eukaryotic cells use autophagy and the ubiquitin–proteasome system as their major protein degradation pathways. Upon proteasomal impairment, cells switch to autophagy to ensure proper clearance of clients (the proteasome-to-autophagy switch). The HSPA8 and HSPA1A cochaperone BAG3 has been suggested to be involved in this switch. However, at present it is still unknown whether and to what extent BAG3 can indeed reroute proteasomal clients to the autophagosomal pathway. Here, we show that BAG3 induces the sequestration of ubiquitinated clients into cytoplasmic puncta colabeled with canonical autophagy linkers and markers. Following proteasome inhibition, BAG3 upregulation significantly contributes to the compensatory activation of autophagy and to the degradation of the (poly)ubiquitinated proteins. BAG3 binding to the ubiquitinated clients occurs through the BAG domain, in competition with BAG1, another BAG family member, that normally directs ubiquitinated clients to the proteasome. Therefore, we propose that following proteasome impairment, increasing the BAG3/BAG1 ratio ensures the “BAG-instructed proteasomal to autophagosomal switch and sorting” (BIPASS). PMID:25046115
Minoia, Melania; Boncoraglio, Alessandra; Vinet, Jonathan; Morelli, Federica F; Brunsting, Jeanette F; Poletti, Angelo; Krom, Sabine; Reits, Eric; Kampinga, Harm H; Carra, Serena
2014-09-01
Eukaryotic cells use autophagy and the ubiquitin-proteasome system as their major protein degradation pathways. Upon proteasomal impairment, cells switch to autophagy to ensure proper clearance of clients (the proteasome-to-autophagy switch). The HSPA8 and HSPA1A cochaperone BAG3 has been suggested to be involved in this switch. However, at present it is still unknown whether and to what extent BAG3 can indeed reroute proteasomal clients to the autophagosomal pathway. Here, we show that BAG3 induces the sequestration of ubiquitinated clients into cytoplasmic puncta colabeled with canonical autophagy linkers and markers. Following proteasome inhibition, BAG3 upregulation significantly contributes to the compensatory activation of autophagy and to the degradation of the (poly)ubiquitinated proteins. BAG3 binding to the ubiquitinated clients occurs through the BAG domain, in competition with BAG1, another BAG family member, that normally directs ubiquitinated clients to the proteasome. Therefore, we propose that following proteasome impairment, increasing the BAG3/BAG1 ratio ensures the "BAG-instructed proteasomal to autophagosomal switch and sorting" (BIPASS).
Kwak, Jae; Fan, Maomian; Martin, Jennifer A; Ott, Darrin K; Grigsby, Claude C
2017-01-01
Gas sampling bags have been used for collecting air samples. Tedlar bags are most commonly used, but bleed background chemicals such as N,N-dimethylacetamide and phenol. It is often necessary to remove the contaminant by flushing the bags with pure nitrogen or air. In this study, we identified four chloroprene dimerization products as background contaminants emitted from ALTEF bags that are made of a proprietary polyvinylidene difluoride (PVDF). No monomer chloroprene was detected in the bags analyzed. All of the dimers gradually increased once bags were filled with nitrogen due to diffusion from the bag surface. Flushing the bags with nitrogen reduced their concentrations, but was not effective for removing the contaminants. When the bags that had been flushed with nitrogen 5 times were left for 24 h, they increased again, indicating that the dimers were constantly emitted from the ALTEF bag surface. To our knowledge, these compounds have never been demonstrated in ALTEF or other PVDF bags. Our finding indicates that ALTEF might be incorporated with Neoprene (chloroprene-based polymer) during its manufacturing process.
Dialysis Facility Safety: Processes and Opportunities.
Garrick, Renee; Morey, Rishikesh
2015-01-01
Unintentional human errors are the source of most safety breaches in complex, high-risk environments. The environment of dialysis care is extremely complex. Dialysis patients have unique and changing physiology, and the processes required for their routine care involve numerous open-ended interfaces between providers and an assortment of technologically advanced equipment. Communication errors, both within the dialysis facility and during care transitions, and lapses in compliance with policies and procedures are frequent areas of safety risk. Some events, such as air emboli and needle dislodgments occur infrequently, but are serious risks. Other adverse events include medication errors, patient falls, catheter and access-related infections, access infiltrations and prolonged bleeding. A robust safety system should evaluate how multiple, sequential errors might align to cause harm. Systems of care can be improved by sharing the results of root cause analyses, and "good catches." Failure mode effects and analyses can be used to proactively identify and mitigate areas of highest risk, and methods drawn from cognitive psychology, simulation training, and human factor engineering can be used to advance facility safety. © 2015 Wiley Periodicals, Inc.
Cai, Michael M; Smith, Edward R; Kent, Annette; Huang, Louis; Hewitson, Tim D; McMahon, Lawrence P; Holt, Stephen G
2018-05-23
The accumulation of fetuin-A-containing calciprotein particles (CPP) in the serum of patients with renal disease and those with chronic inflammation may be involved in driving sterile inflammation and extraosseous mineral deposition. We previously showed that both fetuin-A and CPP were present in the peritoneal dialysis (PD) effluent of stable PD patients. It is unknown whether different PD fluids might affect the formation of CPP in vivo Method: Peritoneal effluent from 12 patients was collected after a 6-hour dwell with 7 different commercial PD fluids. Calciprotein particles and inflammatory cytokines were measured by flow cytometry. High inter-subject variability in CPP concentration was observed. Peritoneal dialysis fluids containing 1.75 mmol/L calcium were associated with enhanced formation of CPP in vivo , compared with fluids containing 1.25 mmol/L calcium. Osmotic agent, fluid pH, and glucose concentration did not affect CPP formation. Peritoneal dialysis effluent CPP levels were not associated with changes in inflammatory cytokines. High calcium-containing PD fluids favor intraperitoneal CPP formation. This finding may have relevance for future PD fluid design.
Meira, Rodrigo Dias de; Carbonara, Cinthia Esbrile Moraes; Quadros, Kélcia Rosana da Silva; Santos, Carolina Urbini Dos; Schincariol, Patrícia; Pêssoa, Gustavo de Souza; Arruda, Marco Aurélio Zezzi; Jorgetti, Vanda; Oliveira, Rodrigo Bueno de
2018-06-04
About four decades ago, the relationship between dialysis-dementia and aluminum (Al) began to be established. The restriction of drugs containing Al and improvements on water quality used for dialysis resulted in the clinical disappearance of Al intoxication. However, high prevalence of Al deposition in bone tissue from Brazilian dialysis patients is still being detected. Through the case report of a patient on hemodialysis (HD) for one year, presenting significant Al deposition in bone tissue, we speculated if this problem is not being underestimated. We used extensive investigation to identify potential sources of Al exposure with a careful review of medication history and water quality controls. Al concentration was measured by different methods, including mass spectrometry, in poly-electrolyte concentrate solutions and solution for peritoneal dialysis, in an attempt to elucidate the possible sources of contamination. The objective of this case report is to alert the medical community about a potential high prevalence of Al deposition in bone tissue and to discuss the possible sources of contamination in patients with chronic kidney disease (CKD).
Hemodialysis and water quality.
Coulliette, Angela D; Arduino, Matthew J
2013-01-01
Over 383,900 individuals in the U.S. undergo maintenance hemodialysis that exposes them to water, primarily in the form of dialysate. The quality of water and associated dialysis solutions have been implicated in adverse patient outcomes and is therefore critical. The Association for the Advancement of Medical Instrumentation has published both standards and recommended practices that address both water and the dialyzing solutions. Some of these recommendations have been adopted into Federal Regulations by the Centers for Medicare and Medicaid Services as part of the Conditions for Coverage, which includes limits on specific contaminants within water used for dialysis, dialysate, and substitution fluids. Chemical, bacterial, and endotoxin contaminants are health threats to dialysis patients, as shown by the continued episodic nature of outbreaks since the 1960s causing at least 592 cases and 16 deaths in the U.S. The importance of the dialysis water distribution system, current standards and recommendations, acceptable monitoring methods, a review of chemical, bacterial, and endotoxin outbreaks, and infection control programs are discussed. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.
Conflict when making decisions about dialysis modality.
Chen, Nien-Hsin; Lin, Yu-Ping; Liang, Shu-Yuan; Tung, Heng-Hsin; Tsay, Shiow-Luan; Wang, Tsae-Jyy
2018-01-01
To explore decisional conflict and its influencing factors on choosing dialysis modality in patients with end-stage renal diseases. The influencing factors investigated include demographics, predialysis education, dialysis knowledge, decision self-efficacy and social support. Making dialysis modality decisions can be challenging for patients with end-stage renal diseases; there are pros and cons to both haemodialysis and peritoneal dialysis. Patients are often uncertain as to which one will be the best alternative for them. This decisional conflict increases the likelihood of making a decision that is not based on the patient's values or preferences and may result in undesirable postdecisional consequences. Addressing factors predisposing patients to decisional conflict helps to facilitate informed decision-making and then to improve healthcare quality. A predictive correlational cross-sectional study design was used. Seventy patients were recruited from the outpatient dialysis clinics of two general hospitals in Taiwan. Data were collected with study questionnaires, including questions on demographics, dialysis modality and predialysis education, the Dialysis Knowledge Scale, the Decision Self-Efficacy scale, the Social Support Scale, and the Decisional Conflict Scale. The mean score on the Decisional Conflict Scale was 29.26 (SD = 22.18). Decision self-efficacy, dialysis modality, predialysis education, professional support and dialysis knowledge together explained 76.4% of the variance in decisional conflict. Individuals who had lower decision self-efficacy, did not receive predialysis education on both haemodialysis and peritoneal dialysis, had lower dialysis knowledge and perceived lower professional support reported higher decisional conflict on choosing dialysis modality. When providing decisional support to predialysis stage patients, practitioners need to increase patients' decision self-efficacy, provide both haemodialysis and peritoneal dialysis predialysis education, increase dialysis knowledge and provide professional support. © 2017 John Wiley & Sons Ltd.
Janković, Nikola; Orsanić-Brcić, Dubravka; Pavlović, Drasko; Varlaj-Knobloch, Vesna; Altabas, Karmela
2003-01-01
Every year ever more and more patients in our country receive some form of dialysis, which provides life-saving renal replacement therapy for end-stage renal disease. In an effort to improve the quality and outcomes of dialysis care, the National Kidney Foundation--Dialysis Outcomes Quality Initiative (NKF-DOQI) have developed clinical practice guidelines for care of dialysis patients regarding hemodialysis adequacy, peritoneal dialysis adequacy, treatment of anemia, and vascular access. The morbidity and mortality of patients is strongly connected with dialysis adequacy and degree of anemia. We compared 180 patients on hemodialysis (HD) in 1998 and 177 patients in 2002, who are regularly treated in our Center with the use of DOQI guidelines. Dialysis adequacy was assessed by use of urea reduction ratio URR = 1-(post. urea/pre. urea), and overall wellbeing according to the degree of anemia, number of blood transfusions, presence of elevated blood pressure, and number of antihypertensives in therapy. In year 2002, 50% of the patients had adequate dialysis compared with 30% in 1998. The average duration on dialysis and the age of patients did not change. We recorded a rise in hemoglobin from 80 g/L to 92 g/L, and in the use of EPO (from 18% to 30%). No case of hypoalbuminemia was observed. The aim of dialysis is to improve the overall wellbeing of uremic patients. Comparing our results with DOQI-guidelines, we demonstrated that dialysis therapy could be improved to prevent complications and early mortality in dialysis patients.
Quest for postdialysis urea rebound-equilibrated Kt/V with only intradialytic urea samples.
Jean, G; Charra, B; Chazot, C; Laurent, G
1999-09-01
Postdialysis urea rebound (PDUR) is a cause of Kt/V overestimation when it is calculated from predialysis and the immediate postdialysis blood urea collections. Measuring PDUR requires a 30- or 60-minute postdialysis sampling, which is inconvenient. Several methods had been devised for a reasonable approach to determine PDUR-equilibrated Kt/V in short dialysis without the need for a delayed sample. The aim of our study was to compare these different Kt/V methods during the longer eight-hour hemodialysis sessions, and to determine the optimum intradialytic urea sample time that fits best with PDUR. The study included 21 patients (mean age 71.9 years) who were hemodialyzed for 60+/-60 months at three times eight hours weekly, using bicarbonate dialysate and cellulosic membranes. Blood urea samples were obtained at onset, and then at 17, 33, 50, 66, 75, 80, 85, and 100% of the dialysis session times, after 30 seconds of low flow, and then at 60-minutes postdialysis. All patients had a meal during dialysis. We compared four different formulas of Kt/V [(a) Kt/V-Smye with a 33% dialysis time urea sample, (b) two-pool equilibrated eKt/V, (c) Kt/V-std (Daugirdas-2) obtained with an immediate postdialytic sample, and (d) the different intradialytic urea samples for Kt/V (50, 66, 75, 80, and 85% of dialysis time)] with the equilibrated 60-minute PDUR Kt/V (Kt/V-r-60) formula as the reference method. The mean PDUR was 17.2+/-9%, leading to an overestimation of Kt/V-std by 12.2%. Kt/V-r-60 was 1.68+/-0.34. Kt/V-std was 1.88+/-0.36 (Delta = 12.2+/-4.8%, r = 0.8). eKt/V was 1.77+/-0.3 (Delta = 5+/-5%, r = 0.96), and Kt/V-Smye was 1.79+/-0.47 (Delta = 5.2+/-14%, r = 0.9). The best time for the intradialytic sampling was 80% (that is, at 6 hr and 24 min). The Kt/V-80 was 1.64+/-0.3 and was best fitted with Kt/V-r-60 (Delta = -1.8+/-8%, r = 0.91). The mean intradialytic urea evolution showed a three-exponential rate, in discrepancy with the two-exponential rate theoretical model. These results confirm that a significant postdialysis rebound exists in an eight-hour dialysis. An intradialytic urea sample taken at 80% of the total session time permits an estimation of the 60-minute Kt/V-rebound without the necessity of taking a delayed sample, with better accuracy than eKt/V or especially Kt/V-Smye. This may be related to a particular urea kinetics curve on the longer dialysis duration, which needs to be studied further.
Braver, E R; Ferguson, S A; Greene, M A; Lund, A K
1997-11-05
Virtually all new cars now are equipped with passenger air bags. Determining whether passenger air bags are saving lives is important, particularly because passenger air bags have caused some deaths among children and adults. To assess the effectiveness of passenger air bags in reducing the risk of death in frontal crashes for right front passengers. Air bags are designed to protect occupants in frontal crashes. Using Fatality Analysis Reporting System data for calendar years 1992 through 1995, the relative frequency of right front passenger deaths in frontal vs nonfrontal fatal crashes was compared for cars with dual air bags and for cars with driver-only air bags. Odds of right front passengers dying in frontal compared with nonfrontal fatal crashes were computed for 1992 through 1995 model year cars with dual air bags and for cars with driver-only air bags. Percentage reductions in right front passenger deaths in dual air bag vehicles were estimated. Right front passenger fatalities were 18% lower than expected in frontal crashes of cars with dual air bags and 11% lower in all crashes. An estimated 73 fewer than expected right front passengers died in 1992 through 1995 model cars with dual air bags during 1992 through 1995. The risk of frontal crash death for right front passengers in cars with dual air bags was reduced 14% among those reported to be using belts and 23% among belt nonusers. Children younger than 10 years in cars with dual air bags had a 34% increased risk of dying in frontal crashes. Passenger air bags were associated with substantial reductions in fatalities among right front passengers in frontal crashes. However, more children are being killed than are being saved by air bags. Immediate countermeasures to reduce the dangers of air bags to children and adults are suggested.
The medical director and quality requirements in the dialysis facility.
Schiller, Brigitte
2015-03-06
Four decades after the successful implementation of the ESRD program currently providing life-saving dialysis therapy to >430,000 patients, the definitions of and demands for a high-quality program have evolved and increased at the same time. Through substantial technological advances ESRD care improved, with a predominant focus on the technical aspects of care and the introduction of medications such as erythropoiesis-stimulating agents and active vitamin D for anemia and bone disease management. Despite many advances, the size of the program and the increasingly older and multimorbid patient population have contributed to continuing challenges for providing consistently high-quality care. Medicare's Final Rule of the Conditions for Coverage (April 2008) define the medical director of the dialysis center as the leader of the interdisciplinary team and the person ultimately accountable for quality, safety, and care provided in the center. Knowledge and active leadership with a hands-on approach in the quality assessment and performance improvement process (QAPI) is essential for the achievement of high-quality outcomes in dialysis centers. A collaborative approach between the dialysis provider and medical director is required to optimize outcomes and deliver evidence-based quality care. In 2011 the Centers for Medicare & Medicaid Services introduced a pay-for-performance program-the ESRD quality incentive program (QIP)- with yearly varying quality metrics that result in payment reductions in subsequent years when targets are not achieved during the performance period. Success with the QIP requires a clear understanding of the structure, metrics, and scoring methods. Information on achievement and nonachievement is publicly available, both in facilities (through the facility performance score card) and on public websites (including Medicare's Dialysis Facility Compare). By assuming the leadership role in the quality program of dialysis facilities, the medical director is given an important opportunity to improve patients' lives and effect true change in a patient population dealing with a very challenging chronic disease. This article in the series on the role of the medical director summarizes the medical director's specific role in the quality improvement process in the dialysis facility and the associated requirements and programs, including QAPI and QIP. Copyright © 2015 by the American Society of Nephrology.
Study of the suitability of DUO plastic bags for the storage of dynamites.
Sáiz, Jorge; Ferrando, José-Luis; Atoche, Juan-Carlos; García-Ruiz, Carmen
2013-10-10
A comparative study on the retentiveness of two plastic bags (DUO and Royal Pack) has been carried out by gas chromatography with mass spectrometry detection. Two types of dynamites were packed in both plastic bags. The bags were placed into glass jars and headspace analyses were performed over 11 weeks to detect whether the volatile constituents of the dynamites were released from the bags. DUO plastic bags showed much better retentiveness than Royal Pack plastic bags. Ethylene glycol dinitrate (EGDN) was quickly detected in the headspace of the glass jars containing Royal Pack plastic bags after 1 week of storage. On the contrary, only a weak signal of EGDN, which was not detectable in the total ion chromatogram, was detected after 11 weeks of storage. Moreover, DUO plastic bags have shown less background signals than the Royal Pack bags, being the former bags much more suitable for the storage of dynamites. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Seong Hooi, Lai; Bavanandan, Sunita
2017-01-01
End-stage renal disease (ESRD) is managed by either lifesaving hemodialysis (HD) and peritoneal dialysis (PD) or a kidney transplant. In Malaysia, the prevalence of dialysis-treated ESRD patients has shown an exponential growth from 504 per million population (pmp) in 2005 to 1155 pmp in 2014. There were 1046 pmp patients on HD and 109 pmp patients on PD in 2014. Kidney transplants are limited due to lack of donors. Malaysia adopts public-private financing model for dialysis. Majority of HD patients were treated in the private sector but almost all PD patients were treated in government facilities. Inequality in access to dialysis is visible within geographical regions where majority of HD centres are scattered around developed areas. The expenditure on dialysis has been escalating in recent years but economic evaluations of dialysis modalities are scarce. Evidence shows that health policies and reimbursement strategies influence dialysis provision. Increased uptake of PD can produce significant economic benefits and improve patients' access to dialysis. As a result, some countries implemented a PD-First or Favored Policy to expand PD use. Thus, a current comparative costs analysis of dialysis is strongly recommended to assist decision-makers to establish a more equitable and economically sustainable dialysis provision in the future. PMID:29225970
Abdul Manaf, Mohd Rizal; Surendra, Naren Kumar; Abdul Gafor, Abdul Halim; Seong Hooi, Lai; Bavanandan, Sunita
2017-01-01
End-stage renal disease (ESRD) is managed by either lifesaving hemodialysis (HD) and peritoneal dialysis (PD) or a kidney transplant. In Malaysia, the prevalence of dialysis-treated ESRD patients has shown an exponential growth from 504 per million population (pmp) in 2005 to 1155 pmp in 2014. There were 1046 pmp patients on HD and 109 pmp patients on PD in 2014. Kidney transplants are limited due to lack of donors. Malaysia adopts public-private financing model for dialysis. Majority of HD patients were treated in the private sector but almost all PD patients were treated in government facilities. Inequality in access to dialysis is visible within geographical regions where majority of HD centres are scattered around developed areas. The expenditure on dialysis has been escalating in recent years but economic evaluations of dialysis modalities are scarce. Evidence shows that health policies and reimbursement strategies influence dialysis provision. Increased uptake of PD can produce significant economic benefits and improve patients' access to dialysis. As a result, some countries implemented a PD-First or Favored Policy to expand PD use. Thus, a current comparative costs analysis of dialysis is strongly recommended to assist decision-makers to establish a more equitable and economically sustainable dialysis provision in the future.
42 CFR 84.88 - Breathing bag test.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with... Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of... 42 Public Health 1 2014-10-01 2014-10-01 false Breathing bag test. 84.88 Section 84.88 Public...
NASA Technical Reports Server (NTRS)
1972-01-01
The experimental determination of purge bag materials properties, development of purge bag manufacturing techniques, experimental evaluation of a subscale purge bag under simulated operating conditions and the experimental evaluation of the purge pin concept for MLI purging are discussed. The basic purge bag material, epoxy fiberglass bounded by skins of FEP Teflon, showed no significant permeability to helium flow under normal operating conditions. Purge bag small scale manufacturing tests were conducted to develop tooling and fabrication techniques for use in full scale bag manufacture. A purge bag material layup technique was developed whereby the two plys of epoxy fiberglass enclosed between skins of FEP Teflon are vacuum bag cured in an oven in a single operation. The material is cured on a tool with the shape of a purge bag half. Plastic tooling was selected for use in bag fabrication. A model purge bag 0.6 m in diameter was fabricated and subjected to a series of structural and environmental tests simulating various flight type environments. Pressure cycling tests at high (450 K) and low (200 K) temperature as well as acoustic loading tests were performed. The purge bag concept proved to be structurally sound and was used for the full scale bag detailed design model.
BAG3 affects the nucleocytoplasmic shuttling of HSF1 upon heat stress.
Jin, Young-Hee; Ahn, Sang-Gun; Kim, Soo-A
2015-08-21
Bcl2-associated athoanogene (BAG) 3 is a member of the co-chaperone BAG family. It is induced by stressful stimuli such as heat shock and heavy metals, and it regulates cellular adaptive responses against stressful conditions. In this study, we identified a novel role for BAG3 in regulating the nuclear shuttling of HSF1 during heat stress. The expression level of BAG3 was induced by heat stress in HeLa cells. Interestingly, BAG3 rapidly translocalized to the nucleus upon heat stress. Immunoprecipitation assay showed that BAG3 interacts with HSF1 under normal and stressed conditions and co-translocalizes to the nucleus upon heat stress. We also demonstrated that BAG3 interacts with HSF1 via its BAG domain. Over-expression of BAG3 down-regulates the level of nuclear HSF1 by exporting it to the cytoplasm during the recovery period. Depletion of BAG3 using siRNA results in reduced nuclear HSF1 and decreased Hsp70 promoter activity. BAG3 in MEF(hsf1(-/-)) cells actively translocalizes to the nucleus upon heat stress suggesting that BAG3 plays a key role in the processing of the nucleocytoplasmic shuttling of HSF1 upon heat stress. Copyright © 2015 Elsevier Inc. All rights reserved.
Nishite, Yoshiaki; Takesawa, Shingo
2016-01-01
Background: Accidents that occur during dialysis treatment are notified to the medical staff via alarms raised by the dialysis apparatus. Similar to such real accidents, apparatus activation or accidents can be reproduced by simulating a treatment situation. An alarm that corresponds to such accidents can be utilized in the simulation model. Objectives: The aim of this study was to create an extracorporeal circulation system (hereinafter, the circulation system) for dialysis machines so that it sets off five types of alarms for: 1) decreased arterial pressure, 2) increased arterial pressure, 3) decreased venous pressure, 4) increased venous pressure, and 5) blood leakage, according to the five types of accidents chosen based on their frequency of occurrence and the degree of severity. Materials and Methods: In order to verify the alarm from the dialysis apparatus connected to the circulation system and the accident corresponding to it, an evaluation of the alarm for its reproducibility of an accident was performed under normal treatment circumstances. The method involved testing whether the dialysis apparatus raised the desired alarm from the moment of control of the circulation system, and measuring the time it took until the desired alarm was activated. This was tested on five main models from four dialyzer manufacturers that are currently used in Japan. Results: The results of the tests demonstrated successful activation of the alarms by the dialysis apparatus, which were appropriate for each of the five types of accidents. The time between the control of the circulatory system to the alarm signal was as follows, 1) venous pressure lower limit alarm: 7 seconds; 2) venous pressure lower limit: 8 seconds; 3) venous pressure upper limit: 7 seconds; 4) venous pressure lower limit alarm: 2 seconds; and 5) blood leakage alarm: 19 seconds. All alarms were set off in under 20 seconds. Conclusions: Thus, we can conclude that a simulator system using an extracorporeal circulation system can be set to different models of dialyzers, and that the reproduced treatment scenarios can be used for simulation training. PMID:26981503
Yagi, N; Paganini, E P
1997-07-01
The emergence of dialytic support for patients with reversible renal failure was one of the most significant advances in critical care medicine. Supporting a patient with a failed organ till organ recovery has not had the same success with other organ failures. Despite the indispensable nature of the support, dialysis was intermittent at best, and carried its own morbidity. The emergence of a "continuous" dialysis delivery system, originally through an arteriovenous access and later through veno-venous methodology, began to simulate the continuity of the natural kidney, and lifted much of the fluid and drug restrictions imposed by the intermittent nature of standard dialytic therapies. Components of the system were next reviewed for improvement and biocompatability. Differences in patient outcome were documented with various component comparisons, and disparate patient tolerance of delivery modality was also clearly proven. The hemodynamic stability of continuous treatment created utilization to be focused on the more unstable, the more severely compromised patient group. In this context, comparative studies with intermittent delivery methods showed improved hemodynamic stability among patients treated with continuous renal replacement therapies (CRRT), but no clear difference in patient mortality. Patient characteristics and severity scoring have recently been undertaken to better describe the population, and attempts at dialysis dosing is currently being developed for ARF dialysis recipients. Early results seem to point toward a dialysis dose effect on mortality in certain groups of ICU acute renal failure patients. However, the dialytic process is only depurative and artificial. Plastic membrane bio-incompatibility, human physiological responses to foreign material exposure, either in the circuit material itself or introduced from therapy methodology, pose practical and theoretical problems. Recent advances in the field of bio-artificial technology have allowed the development of functioning hybrid "blood processors," which function as a renal tubule and may be able to not only "clean" blood, but also allow for other cellular functions not currently possible with dead membrane technology. Combining living cells with a continuous delivery method may be the next significant step toward a fully functional renal replacement therapy.
Extending The Shelf Life Of Blood Platelets
NASA Technical Reports Server (NTRS)
Surgenor, Douglas M.
1988-01-01
New method of storing human blood platelets extends vitality for transfusions. Packaged as suspension in sterile liquid in plastic blood bags. Each bag placed between pair of plastic grids, and rubberbands placed around sandwich thus formed to hold together. Stored upright in open air or in container through which air pumped at rate of at least 45 L/min. Ensures that platelets receive ample oxygen and expiratory carbon dioxide form platelets removed before pH drops to harmful levels.
Modeling Concept Dependencies for Event Detection
2014-04-04
Gaussian Mixture Model (GMM). Jiang et al . [8] provide a summary of experiments for TRECVID MED 2010 . They employ low-level features such as SIFT and...event detection literature. Ballan et al . [2] present a method to introduce temporal information for video event detection with a BoW (bag-of-words...approach. Zhou et al . [24] study video event detection by encoding a video with a set of bag of SIFT feature vectors and describe the distribution with a
Peritoneal dialysis glossary 2009.
Liakopoulos, Vassilios; Stefanidis, Ioannis; Dombros, Nicholas V
2010-06-01
A number of attempts to create a commonly accepted terminology regarding definitions and terms used for clinical entities, methods, problems, and materials encountered by health professionals involved in peritoneal dialysis (PD) were undertaken in the past, the last one in 1990. Later on, some relevant sporadic attempts in a number of textbooks have been made, but they did not include the whole spectrum of PD. This glossary is an attempt to address the need for a universally accepted PD terminology including the latest advances in PD connection systems and fluids.
NASA Astrophysics Data System (ADS)
Dewaele, Hélène; Munier, Simon; Albergel, Clément; Planque, Carole; Laanaia, Nabil; Carrer, Dominique; Calvet, Jean-Christophe
2017-09-01
Soil maximum available water content (MaxAWC) is a key parameter in land surface models (LSMs). However, being difficult to measure, this parameter is usually uncertain. This study assesses the feasibility of using a 15-year (1999-2013) time series of satellite-derived low-resolution observations of leaf area index (LAI) to estimate MaxAWC for rainfed croplands over France. LAI interannual variability is simulated using the CO2-responsive version of the Interactions between Soil, Biosphere and Atmosphere (ISBA) LSM for various values of MaxAWC. Optimal value is then selected by using (1) a simple inverse modelling technique, comparing simulated and observed LAI and (2) a more complex method consisting in integrating observed LAI in ISBA through a land data assimilation system (LDAS) and minimising LAI analysis increments. The evaluation of the MaxAWC estimates from both methods is done using simulated annual maximum above-ground biomass (Bag) and straw cereal grain yield (GY) values from the Agreste French agricultural statistics portal, for 45 administrative units presenting a high proportion of straw cereals. Significant correlations (p value < 0.01) between Bag and GY are found for up to 36 and 53 % of the administrative units for the inverse modelling and LDAS tuning methods, respectively. It is found that the LDAS tuning experiment gives more realistic values of MaxAWC and maximum Bag than the inverse modelling experiment. Using undisaggregated LAI observations leads to an underestimation of MaxAWC and maximum Bag in both experiments. Median annual maximum values of disaggregated LAI observations are found to correlate very well with MaxAWC.
Comparison of human umbilical cord blood processing with or without hydroxyethyl starch.
Souri, Milad; Nikougoftar Zarif, Mahin; Rasouli, Mahboobeh; Golzadeh, Khadijeh; Nakhlestani Hagh, Mozhdeh; Ezzati, Nasim; Atarodi, Kamran
2017-11-01
Umbilical cord blood (UCB) processing with hydroxyethyl starch (HES) is the most common protocol in the cord blood banks. The quality of UCB volume reduction was guaranteed by minimum manipulation of cord blood samples in the closed system. This study aimed to analyze and compare cell recovery and viability of UCB processed using the Sepax automated system in the presence and absence of HES. Thirty UCB bags with a total nucleated cell (TNC) count of more than 2.5 × 10 9 were divided in two bags with equal volume. HES solution was added to one bag and another was intact. Both bags were processed with the Sepax. To determine cell recovery, viability, and potential of colony-forming cells (CFCs), preprocessing, postprocessing, and thawing samples were analyzed. The mean TNC recovery after processing and after thaw was significantly better with the HES method (p < 0.01 for the postprocessing step and p < 0.05 for the postthaw step). There were no significant differences to mononucleated cells (MNCs) and CD34+ cell recovery between the two methods after processing and after thaw. TNC and MNC viability was significantly higher without HES after processing and after thaw (p < 0.01). The results of the CFC assay were similar for both methods after processing and after thaw. These results showed that processing of UCB using the Sepax system with the without-HES protocol due to the lower manipulation of samples could be used as an eligible protocol to reduce the volume of UCB. © 2017 AABB.
Evaluation of Microwave Steam Bags for the Decontamination of Filtering Facepiece Respirators
Fisher, Edward M.; Williams, Jessica L.; Shaffer, Ronald E.
2011-01-01
Reusing filtering facepiece respirators (FFRs) has been suggested as a strategy to conserve available supplies for home and healthcare environments during an influenza pandemic. For reuse to be possible, used FFRs must be decontaminated before redonning to reduce the risk of virus transmission; however, there are no approved methods for FFR decontamination. An effective method must reduce the microbial threat, maintain the function of the FFR, and present no residual chemical hazard. The method should be readily available, inexpensive and easily implemented by healthcare workers and the general public. Many of the general decontamination protocols used in healthcare and home settings are unable to address all of the desired qualities of an efficient FFR decontamination protocol. The goal of this study is to evaluate the use of two commercially available steam bags, marketed to the public for disinfecting infant feeding equipment, for FFR decontamination. The FFRs were decontaminated with microwave generated steam following the manufacturers' instructions then evaluated for water absorption and filtration efficiency for up to three steam exposures. Water absorption of the FFR was found to be model specific as FFRs constructed with hydrophilic materials absorbed more water. The steam had little effect on FFR performance as filtration efficiency of the treated FFRs remained above 95%. The decontamination efficacy of the steam bag was assessed using bacteriophage MS2 as a surrogate for a pathogenic virus. The tested steam bags were found to be 99.9% effective for inactivating MS2 on FFRs; however, more research is required to determine the effectiveness against respiratory pathogens. PMID:21525995
Success of Urgent-Start Peritoneal Dialysis in a Large Canadian Renal Program
Alkatheeri, Ali M.A.; Blake, Peter G.; Gray, Daryl; Jain, Arsh K.
2016-01-01
♦ Background: Many patients start renal replacement therapy urgently on in-center hemodialysis via a central venous catheter, which is considered suboptimal. An alternative approach to manage these patients is to start them on peritoneal dialysis (PD). In this report, we describe the first reported Canadian experience with an urgent-start PD program. Additionally we reviewed the literature in this area. ♦ Methods: In this prospective observational study, we report on our experience in a single academic center. This program started in July 2010. We included patients who initiated PD urgently, that is within 2 weeks of catheter insertion. We followed all incident PD patients until October 2013 for mechanical and infectious complications. Peritoneal dialysis catheters were inserted either percutaneously or laparoscopically and dialysis was initiated in either an inpatient or outpatient setting. ♦ Results: Thirty patients were started on urgent PD during our study period. Follow-up ranged from 28 to 1,050 days. Twenty insertions (66.7 %) were done percutaneously and 10 (33.3%) were laparoscopic. Dialysis was initiated within 2 weeks (range: 0 – 13 days, median = 6 days). Twenty-four patients (80%) started PD in an outpatient setting and 6 patients (20%) required immediate inpatient PD start. Three patients (10%) developed a minor peri-catheter leak during the first week of training that was managed conservatively. There were no episodes of peritonitis or exit-site/tunnel infection during the first 4 weeks post-insertion. Four patients (13.3 %) from the percutaneous insertion group and 2 patients (6.7%) from laparoscopic insertions developed catheter dysfunction due to migration, which was managed by repositioning, without need for catheter replacement or modality switch. ♦ Conclusions: Our results are consistent with other studies in this area and demonstrate that urgent-start PD is an acceptable and safe alternative to hemodialysis in patients who need to start dialysis urgently without established dialysis access. PMID:26374834
2010-01-01
Background The main hypothesis of this study is that neutral pH, low glucose degradation product (GDP) peritoneal dialysis (PD) fluid better preserves residual renal function in PD patients over time compared with conventional dialysate. Methods/Design Inclusion criteria are adult PD patients (CAPD or APD) aged 18-81 years whose first dialysis was within 90 days prior to or following enrolment and who have a residual GFR ≥ 5 ml/min/1.73 m2, a urine output ≥ 400 ml/day and an ability to understand the nature and requirements of this trial. Pregnant or lactating patients or individuals with an active infection at the time of enrolment, a contra-indication to PD or participation in any other clinical trial where an intervention is designed to moderate rate of change of residual renal function are excluded. Patients will be randomized 1:1 to receive either neutral pH, low GDP dialysis solution (Balance®) or conventional dialysis solution (Stay.safe®) for a period of 2 years. During this 2 year study period, urinary urea and clearance measurements will be performed at 0, 3, 6, 9, 12, 18 and 24 months. The primary outcome measure will be the slope of residual renal function decline, adjusted for centre and presence of diabetic nephropathy. Secondary outcome measures will include time from initiation of peritoneal dialysis to anuria, peritoneal small solute clearance, peritoneal transport status, peritoneal ultrafiltration, technique survival, patient survival, peritonitis rates and adverse events. A total of 185 patients has been recruited into the trial. Discussion This investigator-initiated study has been designed to provide evidence to help nephrologists determine the optimal dialysis solution for preserving residual renal function in PD patients. Trial Registration Australian New Zealand Clinical Trials Registry Number: ACTRN12606000044527 PMID:20843375
Kang, Seok Hui; Do, Jun Young; Lee, So-Young; Kim, Jun Chul
2017-01-01
Background Health-related quality of life (HRQoL) surveys are needed to evaluate regional and ethnic specificies. The aim of the present study was to evaluate the differences in HRQoL, frailty, and disability according to dialysis modality in the Korean population. Patients and methods We enrolled relatively stable maintenance dialysis patients. A total of 1,616 patients were recruited into our study. The demographic and laboratory data collected at enrollment included age, sex, comorbidities, frailty, disability, and HRQoL scales. Results A total of 1,250 and 366 participants underwent hemodialysis (HD) and peritoneal dialysis (PD), respectively. The numbers of participants with pre-frailty and frailty were 578 (46.2%) and 422 (33.8%) in HD patients, and 165 (45.1%) and 137 (37.4%) in PD patients, respectively (P = 0.349). Participants with a disability included 195 (15.6%) HD patients and 109 (29.8%) PD patients (P < 0.001). On multivariate analysis, the mean physical component scale (PCS) and mental component scale (MCS), symptom/problems, and sleep scores were higher in HD patients than in PD patients. Cox regression analyses showed that an increased PCS in both HD and PD patients was positively associated with patient survival and first hospitalization–free survival. An increased MCS in both HD and PD patients was positively associated with first hospitalization–free survival only. Conclusion There was no significant difference in frailty between patients treated with the two dialysis modalities; however, disability was more common in PD patients than in HD patients. The MCS and PCS were more favorable in HD patients than in PD patients. Symptom/problems, sleep, quality of social interaction, and social support were more favorable in HD patients than in PD patients; however, patient satisfaction and dialysis staff encouragement were more favorable in PD patients than in HD patients. PMID:28467472
Hayashi, Terumasa; Kimura, Tomonori; Yasuda, Keiko; Sasaki, Koichi; Obi, Yoshitsugu; Nagayama, Harumi; Ohno, Motoki; Uematsu, Kazusei; Tamai, Takehiro; Nishide, Takahiro; Rakugi, Hiromi; Isaka, Yoshitaka
2016-01-01
There is a paucity of studies on whether early referral (ER) to nephrologist could reduce cardiovascular mortality on dialysis, and the length of pre-dialysis nephrological care needed to reduce mortality on dialysis. A total of 604 consecutive patients who started dialysis between 2001 and 2009 in Senshu region, Osaka, Japan were analyzed. Non-linear associations between mortality and pre-dialysis duration of nephrological care were assessed using restricted cubic spline function, and predictors for death analyzed on Cox modeling. A total of 31.6%, 18.2%, 11.3% and 6.1% of patients had >12, 24, 36 and 48 months of pre-dialysis care, respectively. A total of 258 patients (42.7%) were categorized as ER (≥6 months pre-dialysis duration). During the follow-up period (median, 31.1 months), 218 patients died (cardiovascular, n=70; infection, n=69). Although patients with late referral (LR) had a proxy of inappropriate pre-dialysis care compared with the ER group, Cox multivariate analysis failed to show a favorable association between ER and cardiovascular outcome. In contrast, a deleterious effect of LR on overall survival was observed but was limited only to the first 12 months of dialysis (HR, 1.957; 95% CI: 1.104-3.469; P=0.021), but not observed thereafter. Current pre-dialysis nephrological care may reduce short-term mortality but may not improve cardiovascular mortality after dialysis initiation.
Comparative Effectiveness of Renin-Angiotensin System Antagonists in Maintenance Dialysis Patients
Shireman, Theresa I.; Mahnken, Jonathan D.; Phadnis, Milind A.; Ellerbeck, Edward F.; Wetmore, James B.
2017-01-01
Background/Aims Whether angiotensin converting enzyme inhibitors (ACE) and angiotensin receptor blockers (ARB) are differentially associated with reductions in cardiovascular events and mortality in patients receiving maintenance dialysis is uncertain. We compared outcomes between ACE and ARB users among hypertensive, maintenance dialysis patients. Methods National retrospective cohort study of hypertensive, Medicare-Medicaid eligible patients initiating chronic dialysis between 1/1/2000 to 12/31/2005. The exposure of interest was new use of either an ACEI or ARB. Outcomes were all-cause mortality (ACM) and combined cardiovascular hospitalization or death (CV-endpoint). Cox proportion hazards models were used to compare the effect of ACEI vs ARB use on ACM and, separately, CV-endpoint. Results ACM models were based on 3,555 ACEI and 1,442 ARB new users, while CV-endpoint models included 3,289 ACEI and 1,346 ARB new users. After statistical adjustments, ACEI users had higher hazard ratios for ACM (AHR = 1.22, 99% CI 1.05–1.42) and CV-endpoint (AHR = 1.12, 99% CI 0.99–1.27). Conclusions Patients initiating maintenance dialysis who received an ACEI faced an increased risk for mortality and a trend towards an increased risk for CV-endpoints when compared to patients who received an ARB. Validation of these results in a rigorous clinical trial is warranted. PMID:27871075
USDA-ARS?s Scientific Manuscript database
The deltamethrin-incorporated polypropylene (PP) bag, ZeroFly® Storage Bag, is a new technology to reduce postharvest losses caused by stored-product insect pests. ZeroFly bags filled with untreated maize were compared to PP bags filled with maize treated with Betallic Super (80 g pirimiphos-methyl ...
Improved method for mutagenicity testing of gaseous compounds by using a gas sampling bag.
Araki, A; Noguchi, T; Kato, F; Matsushima, T
1994-05-01
A simple and safety gas exposure method was developed using a gas sampling bag as an exposure vessel and a preparation vessel of diluted gas. The gas exposure conditions such as amount of S9 in the plate, volume of gas for the plate, amount of top agar, exposure period and exposure temperature were examined by mutagenicity testing of 1,3-butadiene using the gas sampling bag. Mutagenicity tests of 14 compounds and 1,3-butadiene on S. typhimurium TA98, TA100, TA1535 and TA1537, and E. coli WP2 uvrA were also examined by the developed gas exposure method. 1,3-Butadiene, propyne (methyl acetylene), monochlorodifluoromethane, ethylchloride, diborane and silane were mutagenic. 1-Butene, 2-butene, 2-methylpropene, methyl vinyl ether, trichlorofluoromethane, dichlorodifluoromethane, 1,2-dichloro-1,1,2,2-tetrafluoroethane, 1,1-difluoroethane and phosphine were not mutagenic on S. typhimurium TA98, TA100, TA1535 and TA1537, and E. coli WP2 uvrA with or without metabolic activation. These results were compatible with a previous report, and this developed method has the advantage that it can be tested easily and safely for combustible and self-combustible substances such as 1,3-butadiene and silane.
Improving ensemble decision tree performance using Adaboost and Bagging
NASA Astrophysics Data System (ADS)
Hasan, Md. Rajib; Siraj, Fadzilah; Sainin, Mohd Shamrie
2015-12-01
Ensemble classifier systems are considered as one of the most promising in medical data classification and the performance of deceision tree classifier can be increased by the ensemble method as it is proven to be better than single classifiers. However, in a ensemble settings the performance depends on the selection of suitable base classifier. This research employed two prominent esemble s namely Adaboost and Bagging with base classifiers such as Random Forest, Random Tree, j48, j48grafts and Logistic Model Regression (LMT) that have been selected independently. The empirical study shows that the performance varries when different base classifiers are selected and even some places overfitting issue also been noted. The evidence shows that ensemble decision tree classfiers using Adaboost and Bagging improves the performance of selected medical data sets.
Accommodation-Amplitudes following an Accommodative Lens Refilling Procedure — an in vivo Update
Nishi, Okihiro; Nishi, Yutaro; Chang, S.; Nishi, Kayo
2014-01-01
Purpose To investigate whether a newly developed lens refilling procedure can provide some accommodation in monkey eyes and to evaluate the difference in accommodation with different degrees of capsular bag refilling. Setting Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Design Experimental monkey study. Methods Following a central 3–4 mm continuous curvilinear capsulorhexis, phacoemulsification was performed in the usual manner. A novel accommodative membrane intraocular lens for sealing capsular opening was implanted into the capsular bag. Silicone polymers were injected beneath the intraocular lens into the capsular bag through the delivery hole. In three study groups, each with six monkey eyes, the lens capsule was refilled with 0.08 ml corresponding to 65% bag volume, 0.1 ml corresponding to 80% bag volume, and 0.125 ml of silicone polymers corresponding to 100% bag volume, respectively. To calculate the accommodation-amplitudes achieved, automated refractometry was performed before and 1 hour after the topical 4% pilocarpine application before and four weeks after surgery. Results The refilling technique was successful in all monkeys without polymer leakage. Accommodation-amplitudes attained were 2.56 ± 0.74 dioptries (D), 2.42 ± 1.00D, and 2.71 ± 0.63D, respectively, 4 weeks after surgery in the three study groups. Conclusions Using the technique, some accommodation could be obtained in the young monkey eyes. Leakage of the injectable silicone polymer and anterior capsular opacification at least in the visual axis could be avoided. The results suggest that this lens refilling procedure warrants further studies for a possible clinical application. PMID:24461501
Kanisek, Sanja; Gmajnić, Rudika; Barać, Ivana
2018-01-01
Abstract Introduction The proper classification of sharp and infectious waste in situ by the healthcare workers is an important measure of prevention of sharps and other exposure incidents in non-healthcare workers, who handle such waste. The aim was to examine the practice of classifying sharp and infectious waste in family and dental practices. Methods An analysis of 50 bags of infectious and 50 bags of municipal waste from five family and five dental practices for five days in October 2016 at the Health centre Osijek. Results Healthcare workers in 70% of the practices deposited sharps in infectious waste. In 56% of infectious waste bags, sharp object were found. More risky bags of infectious waste were produced by family practices (64%), but with no significant differences in relation to dental practices (48%), (P=0.143). Disposing of infectious into municipal waste was the case in 90% of the practitioners, where in 60% of municipal waste bags, infectious waste was disposed. Dental practices produced more risky bags of municipal waste (76%) in relation to family practices (44%), but with no significant difference (P=0.714). Conclusions The results of this research point to importance of performing audits of proper disposal of sharps and infectious waste to reduce the risks of injury to non-healthcare workers who come into contact with the said waste. Given results could be used for framing written protocols of proper disposal of sharps and infectious waste that should be visibly available in family and dental practices and for education of healthcare workers. PMID:29651317
Roth, W; Grimmel, C; Rieger, L; Strik, H; Takayama, S; Krajewski, S; Meyermann, R; Dichgans, J; Reed, J C; Weller, M
2000-04-01
Bag-1 is a heat shock 70 kDa (Hsp70)-binding protein that can collaborate with Bcl-2 in suppressing apoptosis under some conditions. Here, we report that 11 of 12 human glioma cell lines express Bag-1 protein in vitro. Moreover, 15 of 19 human glioblastomas expressed Bag-1 as assessed by immunohistochemistry in primary tumor specimens. To examine the biological effects of Bag-1 in glioma cells, we expressed Bag-1 or Bcl-2 transgenes in 2 human malignant glioma cell lines, LN-18 and LN-229. Bag-1 significantly slowed glioma cell growth and reduced clonogenicity of both cell lines in vitro. Coexpressed Bcl-2 abrogated these effects of Bag-1. Intracranial LN-229 glioma xenografts implanted into nude mice revealed a substantial growth advantage afforded by Bcl-2. Bag-1 had no such effect, either in the absence or presence of Bcl-2. Upon serum starvation in vitro, Bcl-2 prevented cell death whereas Bag-1 did not. Both Bcl-2 and Bag-1 slowed proliferation of serum-starved cells when expressed alone. Importantly, coexpression of Bcl-2 and Bag-1 provided a distinct growth advantage under conditions of serum starvation that is probably the result of (i) the death-preventing activity of Bcl-2 and (ii) the property of Bag-1 to overcome a Bcl-2-mediated enhancement of exit from the cell cycle. In contrast to these Bcl-2/Bag-1 interactions observed under serum starvation conditions, Bag-1 did not further enhance the strong protection from staurosporine-, CD95 (Fas/Apo1) ligand-, Apo2 ligand (TRAIL)- or chemotherapeutic drug-induced apoptosis afforded by Bcl-2. Taken together, these results indicate a role for Bag-1/Bcl-2 interactions in providing a survival advantage to cancer cells in a deprived microenvironment that may be characteristic of ischemic/hypoxic tumors such as human glioblastoma multiforme, and suggest that Bcl-2/Bag-1 interactions also modulate cell proliferation.
Bcl-2–associated athanogene 3 protects the heart from ischemia/reperfusion injury
Su, Feifei; Myers, Valerie D.; Knezevic, Tijana; Wang, JuFang; Gao, Erhe; Madesh, Muniswamy; Tahrir, Farzaneh G.; Gupta, Manish K.; Gordon, Jennifer; Rabinowitz, Joseph; Tilley, Douglas G.; Khalili, Kamel; Cheung, Joseph Y.
2016-01-01
Bcl-2–associated athanogene 3 (BAG3) is an evolutionarily conserved protein expressed at high levels in the heart and the vasculature and in many cancers. While altered BAG3 expression has been associated with cardiac dysfunction, its role in ischemia/reperfusion (I/R) is unknown. To test the hypothesis that BAG3 protects the heart from reperfusion injury, in vivo cardiac function was measured in hearts infected with either recombinant adeno-associated virus serotype 9–expressing (rAAV9-expressing) BAG3 or GFP and subjected to I/R. To elucidate molecular mechanisms by which BAG3 protects against I/R injury, neonatal mouse ventricular cardiomyocytes (NMVCs) in which BAG3 levels were modified by adenovirus expressing (Ad-expressing) BAG3 or siBAG3 were exposed to hypoxia/reoxygenation (H/R). H/R significantly reduced NMVC BAG3 levels, which were associated with enhanced expression of apoptosis markers, decreased expression of autophagy markers, and reduced autophagy flux. The deleterious effects of H/R on apoptosis and autophagy were recapitulated by knockdown of BAG3 with Ad-siBAG3 and were rescued by Ad-BAG3. In vivo, treatment of mice with rAAV9-BAG3 prior to I/R significantly decreased infarct size and improved left ventricular function when compared with mice receiving rAAV9-GFP and improved markers of autophagy and apoptosis. These findings suggest that BAG3 may provide a therapeutic target in patients undergoing reperfusion after myocardial infarction. PMID:27882354
A mini-bag technique for evaluation of fungicide effects on Trichoderma spp in mushroom compost.
Abosriwil, Salem O; Clancy, Kevin J
2004-04-01
An in vivo technique was developed to observe colonisation of mushroom compost by Trichoderma spp. Isolates of T. harzianum (Th2), T. harzianum (Th1), T. koningii (Tk) and T. viride (Tv) were artificially introduced into compost using a mini-bag system. Wheat grains, colonised by Trichoderma spp, were placed centrally on a layer of compost at the bottom of 1-litre polythene bags which were then filled with 350 g of spawned or un-spawned compost, and partially sealed. After 14 and 21 days incubation at 27 degrees C, the bags were assessed for recovery of Trichoderma from middle and top zones using a needle stab re-isolation technique and a visual colonisation scoring system. Visible green mould contamination, similar to that observed in practice, developed within 21 days. The visual colonisation scoring was reliably related to the re-isolation success. In this evaluation, Trichoderma spp showed considerable differences in their relative abilities to colonise spawned and un-spawned compost, with Th2 isolates being consistently superior to the other isolates of Th1, Tk and Tv in colonising spawned compost. This technique was employed to evaluate the effects of fungicides on the colonisation of mushroom compost by three Trichoderma spp: Th2, Th1 and Tk, using 1-litre and 5-litre mini-bag systems. Aqueous suspensions of benomyl, carbendazim, thiabendazole, prochloraz and prochloraz+carbendazim incorporated into the compost at 50 mg litre(-1), or applied to spawn at 50 mg kg(-1), reduced the colonisation by Trichoderma spp. Prochloraz and prochloraz+carbendazim were superior to benomyl, carbendazim or thiabendazole in reducing compost colonisation by Th2, Th1 and Tk, with Th2 being the most persistent type, capable of colonising treated compost in the presence of all five fungicides. The prochloraz+carbendazim mixture, not normally used in mushroom production, was equal to or better than prochloraz alone. The incidence of green mould colonisation by Th2 was as extensive in the 5-litre compost bags as in the 1-litre bags, but colonisation by Th1 and Tk was more apparent in the 5-litre bags. The in vivo mini-bag evaluations using wheat grain Trichoderma inoculum and needle stab re-isolation procedures proved an efficient method for studying colonisation and screening for effectiveness of fungicides applied to mushroom compost or spawn.
Philippeau, C; Varloud, M; Julliand, V
2014-05-01
To determine prececal starch digestibili-ty and estimate glucose uptake from the digestion of 4 forms of barley in the small intestine, 4 mature cecally fistulated geldings (449 ± 41 kg BW) fed a 62:38 (wt/wt) meadow hay:concentrate diet at 1.7 kg DM/100 kg BW were included in a 4 × 4 Latin square design experiment. During each period, horses received 80% DM of their concentrate as 1 of the 4 forms of a same batch of barley, whole grain, 2.5 mm ground, steam flaked, and pelleted. Hay was offered in 2 equal meals and concentrate in 2 unequal meals. The starch supply in the morning meal amounted 2.7 g starch/kg BW. At each period, mobile bag DM and starch disappearance was determined. Except for ground barley, each form of barley was 4 mm ground before being introduced in the bag. Nylon bags containing each substrate were intubated in the horse receiving the pelleted barley. Bags were collected in the cecum for 10 h postintubation. At each period, postprandial glycemia was measured on blood samples collected on the 4 horses via an indwelling jugular catheter just before the concentrate morning meal and for 8 h. No hay in the morning meal was given the day of the measurements. Whole blood glucose was analyzed with a portable blood glucose meter. Mobile bag prececal DM disappearance and starch disappearance depended (P < 0.01) on barley form. Prececal starch disappearance of whole barley was the lowest but no difference (P > 0.05) was detected among the 3 processed grains. No significant effect of barley form was found whatever the glycemic parameters. No significant correlation was reported between glycemic parameters and the amount of prececal mobile bag disappeared starch calculated as the starch intake in the morning meal by the mobile bag starch disappearance. To conclude, the whole form of barley exhibited the lowest prececal mobile bag starch disappearance whereas, in relationship with large individual variations, no significant variation has been shown in glycemic parameters. Further investigations should be performed to improve methods for estimating prececal starch digestion of processed cereals in the different digestive segments of horses.
Nakayama, Masaaki; Ishida, Mari; Ogihara, Masahiko; Hanaoka, Kazushige; Tamura, Masahito; Kanai, Hidetoshi; Tonozuka, Yukio; Marshall, Mark R
2015-08-01
Patient socialization and preservation of socioeconomic status are important patient-centred outcomes for those who start dialysis, and retention of employment is a key enabler. This study examined the influence of dialysis inception and modality upon these outcomes in a contemporary Japanese cohort. We conducted a survey of prevalent chronic dialysis patients from 5 dialysis centres in Japan. All patients who had been on peritoneal dialysis (PD) since dialysis inception were recruited, and matched with a sample of those on in-centre haemodialysis (ICHD). We assessed patients' current social functioning (Short Form 36 Health Survey), and evaluated changes to patient employment status, annual income, and general health condition from the pre-dialysis period to the current time. A total of 179 patients were studied (102 PD and 77 ICHD). There were no differences in social functioning by modality. Among them, 113 were employed in the pre-dialysis period with no difference by modality. Of these, 22% became unemployed after dialysis inception, with a corresponding decline in average working hours and annual income. The odds of unemployment after dialysis inception were 5.02 fold higher in those on ICHD compared to those on PD, after adjustment for covariates. There were no changes for those who were already unemployed in the pre-dialysis period. Employment status is significantly hampered by dialysis inception, although PD was associated with superior retention of employment and greater income compared to ICHD. This supports a positive role for PD in preservation of socioeconomic status and potentially other patient-centred outcomes. © 2015 Asian Pacific Society of Nephrology.
[Report on chronic dialysis in France in 2016].
Société Francophone de Néphrologie Dialyse Et Transplantation
2017-04-01
The report on dialysis in France in 2016 from the French Speaking Society of Nephrology Dialysis and Transplantation (SFNDT) provides an exhaustive and documented inventory on dialysis in France. It underlines the organizations that are important in 2016 to maintain a high quality dialysis. Several measures are proposed to maintain and improve the care of dialysis in France: (1) The regulation of dialysis treatment in France must be maintained; (2) a burden of care indicator is proposed to ensure that patients requiring the most care are treated in the centers. Proposals are also made to stimulate peritoneal dialysis offers, (3) to improve the calculation of the cost of dialysis and warn against lower reimbursement rates of dialysis, (4) to reduce transport costs by minimizing transport by ambulance (5). The SFNDT recalls recent recommendations concerning access to the renal transplant waiting list, are recalled; (6) as well as recommendations that require waiting until clinical signs are present to start dialysis (7). The SFNDT makes the proposal to set up advanced renal failure units. These units are expected to develop care that is not supported today: consultation with a nurse, a dietician, a social worker or psychologist, palliative care, and coordination (8). Finally, the financial and human resources for pediatric dialysis should be maintained. Copyright © 2017. Published by Elsevier Masson SAS.
Inomata, Yui; Nagasaka, Shouta; Miyate, Kazuki; Goto, Yuta; Hino, Chizuru; Toukairin, Chihiro; Higashio, Rieko; Ishida, Kinji; Saino, Tomoyuki; Hirose, Masamichi; Tsumura, Hideki; Sanbe, Atsushi
2018-02-19
Bcl-2-associated athanogene 3 (BAG3) is strongly expressed in both cardiac and skeletal muscle. A recent study showed that BAG3 may play a protective role in muscles. Little is known, however, regarding the detailed role of BAG3 in cardiac muscle. To better understand the functional role of cardiac BAG3 in the heart, we generated transgenic (TG) mice that overexpress BAG3. A decrease in fractional shortening, and the induction of cardiac atrial natriuretic peptide, were observed in BAG3 TG mice. Moreover, a marked reduction in the protein level of small HSPs was detected in BAG3 TG mouse hearts. We analyzed the cardiac small HSP levels when either the ubiquitin-proteasome system (UPS) or the autophagy system (AS) was inhibited in BAG3 TG mice. The protein turnovers of small HSPs by the AS were activated in BAG3 TG mouse hearts. Thus, BAG3 is critical for the protein turnover of small HSPs via activation of autophagy in the heart. Copyright © 2018 Elsevier Inc. All rights reserved.
Bagworm bags as portable armour against invertebrate predators.
Sugiura, Shinji
2016-01-01
Some animals have evolved the use of environmental materials as "portable armour" against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae). Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators' mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators.
NASA Astrophysics Data System (ADS)
Mori, Mayuka; Kanaya, Ken
Purpose of this research is to clear present condition and measures to expand of voluntary agreement on plastic shopping bags reduction at the prefectural level. Methods of this research are questionnaire survey to prefectures implementing the agreement and survey by i town page to the number of stores of companies and the number of companies in the prefectures. Findings of this research are as follows: 1. The refusal rate of plastic shopping bags was 10-40% before the implementation of voluntary agreements. And the rate is approximately 70-90% after the implementation. Therefore, before and after the implementation of voluntary agreements, the refusal rate of plastic shopping bags is approximately 40-70% less. 2. It is suggested that the time and number of meetings from proposal to conclusion of the agreement are related in some way, to the ratio of stores participating. On the participation of administration, the ratio of stores participating in the case in which prefecture and cities participate is higher than in the case in which prefecture participates.
BAG3 regulates contractility and Ca(2+) homeostasis in adult mouse ventricular myocytes.
Feldman, Arthur M; Gordon, Jennifer; Wang, JuFang; Song, Jianliang; Zhang, Xue-Qian; Myers, Valerie D; Tilley, Douglas G; Gao, Erhe; Hoffman, Nicholas E; Tomar, Dhanendra; Madesh, Muniswamy; Rabinowitz, Joseph; Koch, Walter J; Su, Feifei; Khalili, Kamel; Cheung, Joseph Y
2016-03-01
Bcl2-associated athanogene 3 (BAG3) is a 575 amino acid anti-apoptotic protein that is constitutively expressed in the heart. BAG3 mutations, including mutations leading to loss of protein, are associated with familial cardiomyopathy. Furthermore, BAG3 levels have been found to be reduced in end-stage non-familial failing myocardium. In contrast to neonatal myocytes in which BAG3 is found in the cytoplasm and involved in protein quality control and apoptosis, in adult mouse left ventricular (LV) myocytes BAG3 co-localized with Na(+)-K(+)-ATPase and L-type Ca(2+) channels in the sarcolemma and t-tubules. BAG3 co-immunoprecipitated with β1-adrenergic receptor, L-type Ca(2+) channels and phospholemman. To simulate decreased BAG3 protein levels observed in human heart failure, we targeted BAG3 by shRNA (shBAG3) in adult LV myocytes. Reducing BAG3 by 55% resulted in reduced contraction and [Ca(2+)]i transient amplitudes in LV myocytes stimulated with isoproterenol. L-type Ca(2+) current (ICa) and sarcoplasmic reticulum (SR) Ca(2+) content but not Na(+)/Ca(2+) exchange current (INaCa) or SR Ca(2+) uptake were reduced in isoproterenol-treated shBAG3 myocytes. Forskolin or dibutyryl cAMP restored ICa amplitude in shBAG3 myocytes to that observed in WT myocytes, consistent with BAG3 having effects upstream and at the level of the receptor. Resting membrane potential and action potential amplitude were unaffected but APD50 and APD90 were prolonged in shBAG3 myocytes. Protein levels of Ca(2+) entry molecules and other important excitation-contraction proteins were unchanged in myocytes with lower BAG3. Our findings that BAG3 is localized at the sarcolemma and t-tubules while modulating myocyte contraction and action potential duration through specific interaction with the β1-adrenergic receptor and L-type Ca(2+) channel provide novel insight into the role of BAG3 in cardiomyopathies and increased arrhythmia risks in heart failure. Copyright © 2016 Elsevier Ltd. All rights reserved.
BAG3 regulates contractility and Ca2+ homeostasis in adult mouse ventricular myocytes
Feldman, Arthur M.; Gordon, Jennifer; Wang, JuFang; Song, Jianliang; Zhang, Xue-Qian; Myers, Valerie D.; Tilley, Douglas G.; Gao, Erhe; Hoffman, Nicholas E.; Tomar, Dhanendra; Madesh, Muniswamy; Rabinowitz, Joseph; Koch, Walter J.; Su, Feifei; Khalili, Kamel; Cheung, Joseph Y.
2016-01-01
Bcl2-associated athanogene 3 (BAG3) is a 575 amino acid anti-apoptotic protein that is constitutively expressed in the heart. BAG3 mutations, including mutations leading to loss of protein, are associated with familial cardiomyopathy. Furthermore, BAG3 levels have been found to be reduced in end-stage non-familial failing myocardium. In contrast to neonatal myocytes in which BAG3 is found in the cytoplasm and involved in protein quality control and apoptosis, in adult mouse left ventricular (LV) myocytes BAG3 co-localized with Na+-K+-ATPase and L-type Ca2+ channels in the sarcolemma and t-tubules. BAG3 co-immunoprecipitated with β1-adrenergic receptor, L-type Ca2+ channels and phospholemman. To simulate decreased BAG3 protein levels observed in human heart failure, we targeted BAG3 by shRNA (shBAG3) in adult LV myocytes. Reducing BAG3 by 55% resulted in reduced contraction and [Ca2+]i transient amplitudes in LV myocytes stimulated with isoproterenol. L-type Ca2+ current (ICa) and sarcoplasmic reticulum (SR) Ca2+ content but not Na+/Ca2+ exchange current (INaCa) or SR Ca2+ uptake were reduced in isoproterenol-treated shBAG3 myocytes. Forskolin or dibutyrl cAMP restored ICa amplitude in shBAG3 myocytes to that observed in WT myocytes, consistent with BAG3 having effects upstream and at the level of the receptor. Resting membrane potential and action potential amplitude were unaffected but APD50 and APD90 were prolonged in shBAG3 myocytes. Protein levels of Ca2+ entry molecules and other important excitation-contraction proteins were unchanged in myocytes with lower BAG3. Our findings that BAG3 is localized at the sarcolemma and t-tubules while modulating myocyte contraction and action potential duration through specific interaction with the β1-adrenergic receptor and L-type Ca2+ channel provide novel insight into the role of BAG3 in cardiomyopathies and increased arrhythmia risks in heart failure. PMID:26796036
A new possible picture of the hadron structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pokrovsky, Yury E.
A new chiral-scale invariant version of the bag model (CSB) is developed and applied to calculations of masses and radii for single bag states. The mass formula of the CSB model contains no free parameters and connects masses and radii of the bags with fundamental QCD scales, namely with {lambda}{sub QCD},
Ikigai, H; Seki, K; Nishihara, S; Masuda, S
1988-01-01
A simplified method for preparation of concentrated exoproteins including protein A and alpha-toxin produced by Staphylococcus aureus was successfully devised. The concentrated proteins were obtained by cultivating S. aureus organisms on the surface of a liquid medium-containing cellophane bag enclosed in a sterilized glass flask. With the same amount of medium, the total amount of proteins obtained by the method presented here was identical with that obtained by conventional liquid culture. The concentration of proteins obtained by the method, however, was high enough to observe their distinct bands stained on polyacrylamide gel electrophoresis. This method was considered quite useful not only for large-scale cultivation for the purification of staphylococcal proteins but also for small-scale study using the proteins. The precise description of the method was presented and its possible usefulness was discussed.
BagReg: Protein inference through machine learning.
Zhao, Can; Liu, Dao; Teng, Ben; He, Zengyou
2015-08-01
Protein inference from the identified peptides is of primary importance in the shotgun proteomics. The target of protein inference is to identify whether each candidate protein is truly present in the sample. To date, many computational methods have been proposed to solve this problem. However, there is still no method that can fully utilize the information hidden in the input data. In this article, we propose a learning-based method named BagReg for protein inference. The method firstly artificially extracts five features from the input data, and then chooses each feature as the class feature to separately build models to predict the presence probabilities of proteins. Finally, the weak results from five prediction models are aggregated to obtain the final result. We test our method on six public available data sets. The experimental results show that our method is superior to the state-of-the-art protein inference algorithms. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Dumler Md, Francis
2010-04-01
Bioelectrical impedance analysis is an established technique for body composition analysis. The phase angle parameter, an index of body cell mass, tissue hydration, and membrane integrity, makes it suitable for assessing nutritional status and survivability. We evaluated the significance of a low phase angle value on nutritional status and mortality in 285 chronic dialysis patients during a longitudinal prospective observational study. Patients in the lower phase angle tertile had decreased body weight, body mass index, fat free mass, body cell mass, and lower serum albumin concentrations than those in the higher tertile (P<001). In addition, mortality rates were significantly lower (P=0.05) in the highest tertile patients. In conclusion, the phase angle is a useful method for identifying dialysis patients at high risk for malnutrition and increased mortality.
Rocco, Michael V; Frankenfield, Diane L; Prowant, Barbara; Frederick, Pamela; Flanigan, Michael J
2003-04-01
It is not known if patient prescriptions are being changed if patients are receiving an inadequate dose of peritoneal dialysis. Data from the 2000 Centers for Medicare and Medicaid were used to obtain data on dialysis adequacy and dialysis prescriptions. A total of 359 of 1,268 (28%) adult peritoneal dialysis patients had a total weekly Kt/V urea (twKt/V) less than 2.0 and 436 of 1,245 (35%) patients had a total weekly creatinine clearance (twCrCl) less than 60 L/wk/1.73 m2, defined as "inadequate dialysis." Among chronic ambulatory peritoneal dialysis (CAPD) patients, 81 of 188 (43%) patients had inadequate dialysis and a change in the peritoneal dialysis prescription within 6 months of the initial adequacy value. Among cycler patients, 106 of 197 (54%) patients had inadequate dialysis and a change in the prescription. Thirty-six of 46 (78%) CAPD patients and 48 of 56 (86%) cycler patients had an improvement in twKt/V after the prescription was revised. Thirty-two of 42 (76%) CAPD patients and 45 of 57 (79%) cycler patients had an improvement in twCrCl after the prescription was changed. For these patients, twKt/V increased from 1.6 +/- 0.3 to 2.1 +/- 0.5, with an increase in the peritoneal Kt/V urea from 1.5 +/- 0.3 to 1.9 +/- 0.4. Similarly, twCrCl increased from 46.3 +/- 7.5 to 59.1 +/- 10.6 L/wk/1.73 m2 with an increase in the peritoneal CrCl dose from 42.0 +/- 9.1 to 52.7 +/- 9.9 L/wk/1.73 m2. About half of peritoneal dialysis patients with inadequate dialysis did not have a prescription change and could benefit from modifications in their dialysis prescription.
Ruparelia, Avnika A; Oorschot, Viola; Vaz, Raquel; Ramm, Georg; Bryson-Richardson, Robert J
2014-12-01
Mutations in the co-chaperone Bcl2-associated athanogene 3 (BAG3) can cause myofibrillar myopathy (MFM), a childhood-onset progressive muscle disease, characterized by the formation of protein aggregates and myofibrillar disintegration. In contrast to other MFM-causing proteins, BAG3 has no direct structural role, but regulates autophagy and the degradation of misfolded proteins. To investigate the mechanism of disease in BAG3-related MFM, we expressed wild-type BAG3 or the dominant MFM-causing BAG3 (BAG3(P209L)) in zebrafish. Expression of the mutant protein results in the formation of aggregates that contain wild-type BAG3. Through the stimulation and inhibition of autophagy, we tested the prevailing hypothesis that impaired autophagic function is responsible for the formation of protein aggregates. Contrary to the existing theory, our studies reveal that inhibition of autophagy is not sufficient to induce protein aggregation. Expression of the mutant protein, however, did not induce myofibrillar disintegration and we therefore examined the effect of knocking down Bag3 function. Loss of Bag3 resulted in myofibrillar disintegration, but not in the formation of protein aggregates. Remarkably, BAG3(P209L) is able to rescue the myofibrillar disintegration phenotype, further demonstrating that its function is not impaired. Together, our knockdown and overexpression experiments identify a mechanism whereby BAG3(P209L) aggregates form, gradually reducing the pool of available BAG3, which eventually results in BAG3 insufficiency and myofibrillar disintegration. This mechanism is consistent with the childhood onset and progressive nature of MFM and suggests that reducing aggregation through enhanced degradation or inhibition of nucleation would be an effective therapy for this disease.
Stankuvienė, Asta; Ziginskienė, Edita; Kuzminskis, Vytautas; Bumblytė, Inga Arūnė
2010-01-01
The question of the targets of dialysis dosing remains controversial since the beginning of the long-term dialysis treatment era. It is still uncertain if higher dialysis dose is better. The aim of our study was to investigate issues of dialysis dose in Lithuania during the period of 1998-2005 and to determine associations between hemodialysis dose and survival of patients on chronic hemodialysis. We analyzed data of all patients who started hemodialysis due to end-stage renal disease in Lithuania between January 1, 1998, and December 31, 2005. The information about hemodialysis frequency, duration, and adequacy (according to Kt/V) was obtained from medical documentation. The overall survival rate was estimated using the Kaplan-Meier method. Survival comparisons were made using the log-rank or Breslow tests. Univariate Cox proportional hazards analysis was used to select variables significantly associated with the risk of death; then these variables were included in multivariate Cox proportional hazards models. During the study period, from 2428 patients who started chronic hemodialysis, 58.5% of patients started hemodialysis three times a week. More than one-third (36.2%) of patients were dialyzed twice weekly, and 5.3% of patients started hemodialysis once weekly. Survival analysis revealed that patients dialyzed less than three times per week survived shorter than patients receiving a higher dialysis dose. Duration of HD session of ≤8 hours per week was an independent risk factor for mortality. A higher mean Kt/V was associated with better survival of patients on chronic hemodialysis. Dialysis frequency and weekly duration of HD sessions were dependent on HD accessibility in Lithuania during the period of 1998-2005. Better survival of patients on chronic hemodialysis was associated with a higher hemodialysis dose.
Survival on Home Dialysis in New Zealand
Marshall, Mark R.; Walker, Rachael C.; Polkinghorne, Kevan R.; Lynn, Kelvin L.
2014-01-01
Background New Zealand (NZ) has a high prevalence of both peritoneal dialysis (PD) and home haemodialysis (HD) relative to other countries, and probably less selection bias. We aimed to determine if home dialysis associates with better survival than facility HD by simultaneous comparisons of the three modalities. Methods We analysed survival by time-varying dialysis modality in New Zealanders over a 15-year period to 31-Dec-2011, adjusting for patient co-morbidity by Cox proportional hazards multivariate regression. Results We modelled 6,419 patients with 3,254 deaths over 20,042 patient-years of follow-up. Patients treated with PD and facility HD are similar; those on home HD are younger and healthier. Compared to facility HD, home dialysis (as a unified category) associates with an overall 13% lower mortality risk. Home HD associates with a 52% lower mortality risk. PD associates with a 20% lower mortality risk in the early period (<3 years) that is offset by a 33% greater mortality risk in the late period (>3 years), with no overall net effect. There was effect modification and less observable benefit associated with PD in those with diabetes mellitus, co-morbidity, and in NZ Maori and Pacific People. There was no effect modification by age or by era. Conclusion Our study supports the culture of home dialysis in NZ, and suggests that the extent and duration of survival benefit associated with early PD may be greater than appreciated. We are planning further analyses to exclude residual confounding from unmeasured co-morbidity and other sociodemographic factors using database linkage to NZ government datasets. Finally, our results suggest further research into the practice of PD in NZ Maori and Pacific People, as well as definitive study to determine the best timing for switching from PD in the late phase. PMID:24806458
Dai, Lu; Mukai, Hideyuki; Lindholm, Bengt; Heimbürger, Olof; Barany, Peter; Stenvinkel, Peter
2017-01-01
Background The value of subjective global assessment (SGA) as nutritional assessor of protein-energy wasting (PEWSGA) in chronic kidney disease (CKD) patients depends on its mortality predictive capacity. We investigated associations of PEWSGA with markers of nutritional status and all-cause mortality in CKD patients. Methods In 1031 (732 CKD1-5 non-dialysis and 299 dialysis) patients, SGA and body (BMI), lean (LBMI) and fat (FBMI) body mass indices, % handgrip strength (% HGS), serum albumin, and high sensitivity C-reactive protein (hsCRP) were examined at baseline. The five-year all-cause mortality predictive strength of baseline PEWSGA and during follow-up were investigated. Results PEWSGA was present in 2% of CKD1-2, 16% of CKD3-4, 31% of CKD5 non-dialysis and 44% of dialysis patients. Patients with PEWSGA (n = 320; 31%) had higher hsCRP and lower BMI, LBMI, FBMI, %HGS and serum albumin. But, using receiver operating characteristics-derived cutoffs, these markers could not classify (by kappa statistic) or explain variations of (by multinomial logistic regression analysis) presence of PEWSGA. In generalized linear models, SGA independently predicted mortality after adjustments of multiple confounders (RR: 1.17; 95% CI: 1.11–1.23). Among 323 CKD5 patients who were re-assessed after median 12.6 months, 222 (69%) remained well-nourished, 37 (11%) developed PEWSGA de novo, 40 (12%) improved while 24 (8%) remained with PEWSGA. The latter independently predicted mortality (RR: 1.29; 95% CI: 1.13–1.46). Conclusions SGA, a valid assessor of nutritional status, is an independent predictor of all-cause mortality both in CKD non-dialysis and dialysis patients that outperforms non-composite nutritional markers as prognosticator. PMID:29211778
Gordon, Elisa J; Feinglass, Joe; Carney, Paula; Vera, Karina; Olivero, Maria; Black, Anne; O'Connor, Kate Grubbs; Baumgart, Jessica MacLean; Caicedo, Juan Carlos
2016-03-01
Hispanic dialysis patients often encounter barriers to learning about living kidney donation and transplantation. Effective culturally targeted interventions to increase knowledge are lacking. We developed a culturally targeted educational website to enhance informed treatment decision making for end-stage kidney disease. A pretest/posttest intervention study was conducted among adult Hispanic patients undergoing dialysis at 5 dialysis centers in Chicago, Illinois. Surveys included a 31-item, multiple-choice pretest/posttest of knowledge about kidney transplantation and living donation, attitudes about the website, Internet use, and demographics. The intervention entailed viewing 3 of 6 website sections for a total of 30 minutes. The pretest/posttest was administered immediately before and after the intervention. Participants completed a second posttest via telephone 3 weeks thereafter to assess knowledge retention, attitudes, and use of the website. Sixty-three patients participated (96% participation rate). Website exposure was associated with a mean 17.1% same day knowledge score increase between pretest and posttest (P < .001). At 3 weeks, participants' knowledge scores remained 11.7% above pretest (P < .001). The greatest knowledge gain from pretest to 3-week follow-up occurred in the Treatment Options (P < .0001) and Cultural Beliefs and Myths (P < .0001) website sections. Most participants (95%) "agreed" or "strongly agreed" that they would recommend the website to other Hispanics. Web-based education for patients undergoing dialysis can effectively increase Hispanics' knowledge about transplantation and living kidney donation. Study limitations include small sample size and single geographic region study. Dialysis facilities could enable website access as a method of satisfying policy requirements to provide education about kidney transplantation. © 2016, NATCO.
What Medical Directors Need to Know about Dialysis Facility Water Management.
Kasparek, Ted; Rodriguez, Oscar E
2015-06-05
The medical directors of dialysis facilities have many operational clinic responsibilities, which on first glance, may seem outside the realm of excellence in patient care. However, a smoothly running clinic is integral to positive patient outcomes. Of the conditions for coverage outlined by the Centers for Medicare and Medicaid Services, one most critical to quality dialysis treatment is the provision of safe purified dialysis water, because there are many published instances where clinic failure in this regard has resulted in patient harm. As the clinical leader of the facility, the medical director is obliged to have knowledge of his/her facility's water treatment system to reliably ensure that the purified water used in dialysis will meet the standards for quality set by the Association for the Advancement of Medical Instrumentation and used by the Centers for Medicare and Medicaid Services for conditions for coverage. The methods used to both achieve and maintain these quality standards should be a part of quality assessment and performance improvement program meetings. The steps for water treatment, which include pretreatment, purification, and distribution, are largely the same, regardless of the system used. Each water treatment system component has a specific role in the process and requires individualized maintenance and monitoring. The medical director should provide leadership by being engaged with the process, knowing the facility's source water, and understanding water treatment system operation as well as the clinical significance of system failure. Successful provision of quality water will be achieved by those medical directors who learn, know, and embrace the requirements of dialysis water purification and system maintenance. Copyright © 2015 by the American Society of Nephrology.
Gowda, Anoop; Bangera, Shobith
2017-01-01
Introduction Globally, incidence of Chronic Kidney Disease (CKD) is rapidly rising with huge burden on the life expectancy of the patients. Regular haemodialysis improves the quality of life in these patients. They get treatment at either government run or private sector hospitals. A difference in disease pattern, comorbidity, patient management and number of access failures can be observed in these set ups. Aim The present study was carried out to find out selection, management and disease pattern of CKD patients admitted for dialysis in government run and private hospital. Materials and Methods A cross-sectional study on patients (18–90 years) admitted and undergoing dialysis at government run (N=129) and private hospital (N=182) was undertaken in Karnataka, India. Parameters like comorbidity (diabetes), number of dialysis per week, number of access failures, and follow up visits were compared between these patients. Chi- squared test was used to compare the data. All tests were two-tailed and p< 0.05 was considered as significant. Results More number of younger patients and associated comorbidity, were seen in patients admitted in government run hospital (p<0.001), with no gender bias in selection of patients for dialysis between the two hospitals. Similarly, follow-ups with nephrologist, number of dialysis done per week and erythropoietin supplements administered were significantly more among private hospital patients (p<0.001). Number of dialysis sessions and mean haemoglobin level was less in government run hospital patients, as compared to those in private hospital. No statistical difference was seen with access failure in both these setups. Conclusion No bias in management of CKD patient was seen among the two sets of hospitals though available facilities seemed to vary. PMID:28969180
Gonzalez, Karla; Ulloa, Jesus G; Moreno, Gerardo; Echeverría, Oscar; Norris, Keith; Talamantes, Efrain
2017-10-23
Latinos in the U.S. are almost twice as likely to progress to End Stage Renal disease (ESRD) compared to non-Latino whites. Patients with ESRD on dialysis experience high morbidity, pre-mature mortality and receive intensive procedures at the end of life (EOL). This study explores intensive procedure preferences at the EOL in older Latino adults. Seventy-three community-dwelling Spanish- and English-Speaking Latinos over the age of 60 with and without ESRD participated in this study. Those without ESRD (n = 47) participated in one of five focus group sessions, and those with ESRD on dialysis (n = 26) participated in one-on-one semi-structured interviews. Focus group and individual participants answered questions regarding intensive procedures at the EOL. Recurring themes were identified using standard qualitative content-analysis methods. Participants also completed a brief survey that included demographics, language preference, health insurance coverage, co-morbidities, Emergency Department visits and functional limitations. The majority of participants were of Mexican origin with mean age of 70, and there were more female participants in the non-ESRD group, compared to the ESRD dialysis dependent group. The dialysis group reported a higher number of co-morbidities and functional limitations. Nearly 69% of those in the dialysis group reported one or more emergency department visits in the past year, compared to 38% in the non-ESRD group. Primary themes centered on 1) The acceptability of a "natural" versus "invasive" procedure 2) Cultural traditions and family involvement 3) Level of trust in physicians and autonomy in decision-making. Our results highlight the need for improved patient- and family-centered approaches to better understand intensive procedure preferences at the EOL in this underserved population of older adults.
Vogt, Barbara Perez; Borges, Mariana Clementoni Costa; Goés, Cassiana Regina de; Caramori, Jacqueline Costa Teixeira
2016-12-01
Muscle wasting is associated with mortality in dialysis patients. The measurement of muscle mass has some limitations, while muscle strength assessment is simple, safe and allows the recognition of patients at risk of progressing to poor outcomes related to malnutrition. The aim of this study is verify if handgrip strength (HGS) is associated with all-cause mortality in patients in maintenance haemodialysis (HD) and peritoneal dialysis (PD). This was an observational retrospective cohort study which included all patients in maintenance HD and PD from July 2012 to October 2014. Patients were followed-up until June 2015. Two-hundred sixty five patients were enrolled (218 HD and 47 PD) and they were followed for 13.4 ± 7.9 months. During the follow-up period, 53 patients (20%) have died, 36 patients (13.6%) have undergone renal transplantation, 13 patients (4.9%) have switched off dialysis method and 5 patients (1.9%) have transferred to another facility. The cut-off of HGS able to predict mortality was 22.5 kg for men and 7 kg for women. Using this cut-off to fit the Kaplan-Meier survival curve, the association of HGS with all-cause mortality for both genders was confirmed. Finally, in the multivariate analysis adjusted for demographic, clinical and nutritional variables, HGS remained significant predictor of mortality, independent of dialysis modality. HGS cut-offs that predict mortality were 22.5 kg for men and 7 kg for women. HGS was associated with mortality independent of dialysis modality. Copyright © 2016 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Ethical Challenges in the Provision of Dialysis in Resource-Constrained Environments.
Luyckx, Valerie A; Miljeteig, Ingrid; Ejigu, Addisu M; Moosa, M Rafique
2017-05-01
The number of patients requiring dialysis by 2030 is projected to double worldwide, with the largest increase expected in low- and middle-income countries (LMICs). Dialysis is seldom considered a high priority by health care funders, consequently, few LMICs develop policies regarding dialysis allocation. Dialysis facilities may exist, but access remains highly inequitable in LMICs. High out-of-pocket payments make dialysis unsustainable and plunge many families into poverty. Patients, families, and clinicians suffer significant emotional and moral distress from daily life-and-death decisions imposed by dialysis. The health system's obligation to provide financial risk protection is an important component of global and national strategies to achieve universal health coverage. An ethical imperative therefore exists to develop transparent dialysis priority-setting guidelines to facilitate public understanding and acceptance of the realistic limits within the health system, and facilitate fair allocation of scarce resources. In this article, we present ethical challenges faced by patients, families, clinicians, and policy makers where dialysis is not universally accessible and discuss the potential ethical consequences of various dialysis allocation strategies. Finally, we suggest an ethical framework for use in policy development for priority setting of dialysis care. The accountability for reasonableness framework is proposed as a procedurally fair decision-making, priority-setting process. Copyright © 2017 Elsevier Inc. All rights reserved.
Fangueiro, Joana F; Calpena, Ana C; Clares, Beatriz; Andreani, Tatiana; Egea, Maria A; Veiga, Francisco J; Garcia, Maria L; Silva, Amélia M; Souto, Eliana B
2016-04-11
Cationic lipid nanoparticles (LNs) have been tested for sustained release and site-specific targeting of epigallocatechin gallate (EGCG), a potential polyphenol with improved pharmacological profile for the treatment of ocular pathologies, such as age-related macular edema, diabetic retinopathy, and inflammatory disorders. Cationic EGCG-LNs were produced by double-emulsion technique; the in vitro release study was performed in a dialysis bag, followed by the drug assay using a previously validated RP-HPLC method. In vitro HET-CAM study was carried out using chicken embryos to determine the potential risk of irritation of the developed formulations. Ex vivo permeation profile was assessed using rabbit cornea and sclera isolated and mounted in Franz diffusion cells. The results show that the use of cationic LNs provides a prolonged EGCG release, following a Boltzmann sigmoidal profile. In addition, EGCG was successfully quantified in both tested ocular tissues, demonstrating the ability of these formulations to reach both anterior and posterior segment of the eye. The pharmacokinetic study of the corneal permeation showed a first order kinetics for both cationic formulations, while EGCG-cetyltrimethylammonium bromide (CTAB) LNs followed a Boltzmann sigmoidal profile and EGCG-dimethyldioctadecylammonium bromide (DDAB) LNs a first order profile. Our studies also proved the safety and non-irritant nature of the developed LNs. Thus, loading EGCG in cationic LNs is recognised as a promising strategy for the treatment of ocular diseases related to anti-oxidant and anti-inflammatory pathways. Copyright © 2016 Elsevier B.V. All rights reserved.
Effects of multilayered bags vs ethylvinyl-acetate bags on oxidation of parenteral nutrition.
Balet, Antònia; Cardona, Daniel; Jané, Salvador; Molins-Pujol, Antoni M; Sánchez Quesada, José Luís; Gich, Ignasi; Mangues, Ma Antònia
2004-01-01
We evaluate the effects of multilayered bags vs ethylvinyl-acetate bags on peroxidate formation of various emulsions for all-in-one total parenteral nutrition solutions (TPN) during storage. Twenty-four parenteral nutritions were prepared with 4 commercial i.v. lipid emulsions (Soyacal 20%, Grifols; Intralipid 20%, Fresenius-Kabi; Lipofundina 20%, Braun; and Clinoleic 20%, Clintex) and 2 different bags (multilayered [ML] bag, Miramed; and 1 ethylvinyl-acetate [EVA] bag, Miramed). Each kind of TPN was prepared in triplicate. Samples were taken at 3 different times: immediately after preparation (time 0), after 6 days at 4 degrees C and 48 hours at 37 degrees C (time 1), and finally after a total of 14 days at 37 degrees C (time 2). Oxidation of TPN was evaluated by analysis of hydroperoxides by ferrous oxidation-xylenol orange (FOX) reactive, lipoperoxides by thiobarbituric acid reactive species (TBARS), alpha-tocopherol by high-performance liquid chromatography (HPLC), and ascorbic acid and dehydroascorbic acid by HPLC. TPN admixtures in ML bag showed less oxidation evaluated by peroxide determination using FOX than EVA bag. Lipoperoxides by TBARS did not show significant differences between 2 bags. Ascorbic acid and dehydroascorbic acid disappeared in EVA bags at time 1. No important differences were found in alpha-tocopherol content. Multilayered bags minimize oxidation.
How have changes in air bag designs affected frontal crash mortality?
Braver, Elisa R; Shardell, Michelle; Teoh, Eric R
2010-07-01
To determine whether front air bag changes have affected occupant protection, frontal crash mortality rates were compared among front outboard occupants in vehicles having certified-advanced air bags (latest generation of air bags) or sled-certified air bags with and without advanced features. Poisson marginal structural models were used to calculate standardized mortality rate ratios (MRRs) for front occupants per registered vehicle. Vehicle age-corrected mortality rates were lower for drivers of vehicles having sled-certified air bags with advanced features than for drivers having sled-certified air bags without advanced features (MRR = 0.88; 95% confidence interval [CI]: 0.81-0.95), including unbelted men and drivers younger than 60. The mortality rate was higher, though not statistically significant, for drivers having certified-advanced air bags compared with sled-certified air bags with advanced features (vehicle age-corrected MRR = 1.13; 95% CI: 0.97-1.32) and significantly higher for belted drivers (MRR = 1.21; 95% CI: 1.04-1.39). Advanced air bag features appeared protective for some occupants. However, increased mortality rates among belted drivers of vehicles having certified-advanced air bags relative to those having sled-certified air bags with advanced features suggest that further study is needed to identify any potential problems with requirements for certification. 2010 Elsevier Inc. All rights reserved.
Overexpressed BAG3 is a potential therapeutic target in chronic lymphocytic leukemia.
Zhu, Huayuan; Wu, Wei; Fu, Yuan; Shen, Wenyi; Miao, Kourong; Hong, Min; Xu, Wei; Young, Ken H; Liu, Peng; Li, Jianyong
2014-03-01
Bcl-2-associated athanogene 3 (BAG3), a member of BAG family, is shown to sustain cell survival and underlie resistance to chemotherapy in human neoplastic cells. We aimed to determine the exact role and underlying mechanisms of BAG3 in human chronic lymphocytic leukemia (CLL). One hundred human CLL samples and 20 normal B-cell samples from healthy controls were collected. We measured the BAG3 expression in these cells and explored its relationship with known prognostic factors for CLL. The roles of BAG3 in cell apoptosis and migration were evaluated by small interfering RNA-mediated knockdown of BAG3 in primary CLL cells. We showed that BAG3 expression level was increased in CLL cells compared with normal B cells. Moreover, BAG3 expression was particularly upregulated in CD38 positive, unmutated immunoglobulin heavy-chain patients and those with lymphadenopathy and/or splenomegaly. Importantly, patients with increased BAG3 expression level have poor overall survival in subgroups with positive ZAP-70 or those without any "p53 abnormality". In addition, knocking down of BAG3 expression resulted in increased apoptotic ratio and decreased migration in primary CLL cells. Our data indicate that BAG3 is a marker of poor prognostic in specific subgroups of CLL patients and may be a potential therapeutic target for this disease.
Ammonia Diffusion through Nalophan Double Bags: Effect of Concentration Gradient Reduction
Capelli, Laura; Boiardi, Emanuela; Del Rosso, Renato
2014-01-01
The ammonia loss through Nalophan bags has been studied. The losses observed for storage conditions and times as allowed by the reference standard for dynamic olfactometry (EN 13725:2003) indicate that odour concentration values due to the presence of small molecules may be significantly underestimated if samples are not analysed immediately after sampling. A diffusion model was used in order to study diffusion through the bag. The study discusses the effect of concentration gradient (ΔC) across the polymeric membrane of the analyte. The ΔC was controlled by using a setup bag called “double bags.” Experimental data show a reduction of ammonia percentage losses due to the effect of the external multibarrier. The expedient of the double bag loaded with the same gas mixture allows a reduced diffusion of ammonia into the inner bag. Comparing the inner bag losses with those of the single bag stored in the same conditions (T, P, u) and with equal geometrical characteristics (S/V, z), it was observed that the inner bag of the double bag displays a 16% loss while the single bag displays a 37% loss. Acting on the ΔC it is possible to achieve a gross reduction of 57% in the ammonia leakage due to diffusion. PMID:25506608
Gill, John S; Rose, Caren; Joffres, Yayuk; Landsberg, David; Gill, Jagbir
2018-05-01
The impact of dialysis exposure before nonpreemptive living donor kidney transplantation on allograft outcomes is uncertain. Retrospective cohort study. Adult first-time recipients of kidney-only living donor transplants in the United States who were recorded within the Scientific Registry of Transplant Recipients for 2000 to 2016. Duration of pretransplantation dialysis exposure. Kidney transplant failure from any cause including death, death-censored transplant failure, and death with allograft function. Among the 77,607 living donor transplant recipients studied, longer pretransplantation dialysis exposure was independently associated with progressively higher risk for transplant failure from any cause, including death beginning 6 months after transplantation. Compared with patients with 0.1 to 3.0 months of dialysis exposure, the HR for transplant failure from any cause including death increased from 1.16 (95% CI, 1.07-1.31) among patients with 6.1 to 9.0 months of dialysis exposure to 1.60 (95% CI, 1.43-1.79) among patients with more than 60.0 months of dialysis exposure. Pretransplantation dialysis exposure varied markedly among centers; median exposures were 11.0 and 18.9 months for centers in the 10th and 90th percentiles of dialysis exposure, respectively. Centers with the highest proportions of living donor transplantations had the shortest pretransplantation dialysis exposures. In multivariable analysis, patients of black race, with low income, with nonprivate insurance, with less than high school education, and not working for income had longer pretransplantation dialysis exposures. Dialysis exposure in patients with these characteristics also varied 2-fold between transplantation centers. Why longer dialysis exposure is associated with transplant failure could not be determined. Longer pretransplantation dialysis exposure in nonpreemptive living donor kidney transplantation is associated with increased risk for allograft failure. Pretransplantation dialysis exposure is associated with recipients' sociodemographic and transplantation centers' characteristics. Understanding whether limiting pretransplantation dialysis exposure could improve living donor transplant outcomes will require further study. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.
Algorithm for optimal dialysis access timing.
Heaf, J G
2007-02-01
Acute initiation of dialysis is associated with increased morbidity due to access and uremia complications. It is frequent despite early referral and regular out-patient control. We studied factors associated with end-stage renal disease (ESRD) progression in order to optimize the timing of dialysis access (DA). In a retrospective longitudinal study (Study 1), the biochemical and clinical course of 255 dialysis and 64 predialysis patients was registered to determine factors associated with dialysis-free survival (DFS). On the basis of these results an algorithm was developed to predict timely DA, defined as >6 weeks and <26 weeks before dialysis initiation, with too late placement weighted twice as harmful as too early. The algorithm was validated in a prospective study (Study 2) of 150 dialysis and 28 predialysis patients. Acute dialysis was associated with increased 90-day hospitalization (17.9 vs. 9.0 days) and mortality (14% vs. 6%). P-creatinine and p-urea were poor indicators of DFS. At any level of p-creatinine, DFS was shorter with lower creatinine clearance and vice versa. Patients with systemic renal disease had a significantly shorter DFS than primary renal disease, due to faster GFR loss and earlier dialysis initiation. Short DFS was seen with hypoalbuminemia and cachexia; these patients were recommended early DA. The following algorithm was used to time DA (units: 1iM and ml/min/1.73 m2): P-Creatinine - 50 x GFR + (100 if Systemic Renal Disease) >200. Use of the algorithm was associated with earlier dialysis placement and a fall in acute dialysis requirements from 50% to 23%. The incidence of too early DA was unchanged (7% vs. 9%), and was due to algorithm non-application. The algorithm failed to predict imminent dialysis in 10% of cases, primarily due to acute exacerbation of stable uremia. Dialysis initiation was advanced by approximately one month. A predialysis program based on early dialysis planning and GFR-based DA timing may reduce the requirement for acute dialysis initiation and patient morbidity and mortality, at the cost of slightly earlier dialysis initiation.
Panesar, Mandip; Shah, Neal; Vaqar, Sarosh; Ivaturi, Kaushik; Gudleski, Gregory; Muscarella, Mary; Lambert, Judy; Su, Winnie; Murray, Brian
2017-04-01
Fresenius Medical Care's NaturaLyte dialysate has been associated with increased risk of sudden cardiac death by causing metabolic alkalosis from its acetate content based on retrospective data using pre-dialysis bicarbonate levels only. The study objective was to measure inter/intra-dialytic changes in serum bicarbonate and degree of alkalosis conferred by varying concentrations of NaturaLyte bicarbonate dialysate. Thirty-nine hemodialysis patients were divided into four groups based on prescribed bicarbonate dialysate concentrations; Group 1 (N = 9): 30-32 mEq/L, Group 2 (N = 5): 33-34 mEq/L, Group 3 (N = 10): 35-36 mEq/L, Group 4 (N = 15): 37-40 mEq/L. Serial (pre-dialysis, immediate post-dialysis, 2 h post-dialysis, and 68 h post-dialysis) bicarbonate levels were measured. Mean pre-dialysis serum bicarbonate levels (representing 44 h post-dialysis levels) in all four groups were not statistically different. Pre-dialysis and 68 h post-dialysis bicarbonate levels in each group were also not significantly different. However, immediate post-dialysis and 2 h post-dialysis bicarbonate levels were significantly increased in all four groups proportional to dialysate dose. There was statistically significant inter-group bicarbonate level difference (P < 0.05) except between the first and second (P = 0.43) and second and third (P = 0.07) groups in the immediate post-dialysis period. Similar results were obtained for the 2 h post-dialysis period. High bicarbonate dialysate causes large and rapid fluctuations in serum bicarbonate levels during the intra/inter-dialytic period, which returns to baseline within 44 to 68 h after dialysis. This refutes the necessity to correct pre-dialysis acidosis with high bicarbonate dialysate since rapid equilibration is likely to occur and unnecessarily exposes patients to large shifts in their acid base balance. © 2017 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.
Treatment decisions for older adults with advanced chronic kidney disease.
Rosansky, Steven J; Schell, Jane; Shega, Joseph; Scherer, Jennifer; Jacobs, Laurie; Couchoud, Cecile; Crews, Deidra; McNabney, Matthew
2017-06-19
Dialysis initiation rates among older adults, aged 75 years or greater, are increasing at a faster rate than for younger age groups. Older adults with advanced CKD (eGFR < 30 ml/min/1.73 m 2 ) typically lose renal function slowly, often suffer from significant comorbidity and thus may die from associated comorbidities before they require dialysis.A patient's pattern of renal function loss over time in relation to their underlying comorbidities can serve as a guide to the probability of a future dialysis requirement. Most who start dialysis, initiate treatment "early", at an estimated glomerulofiltration rate (eGFR) >10 ml/min/1.73 m 2 and many initiate dialysis in hospital, often in association with an episode of acute renal failure. In the US older adults start dialysis at a mean e GFR of 12.6 ml/min/1.73 m 2 and 20.6% die within six months of dialysis initiation. In both the acute in hospital and outpatient settings, many older adults appear to be initiating dialysis for non-specific, non-life threatening symptoms and clinical contexts. Observational data suggests that dialysis does not provide a survival benefit for older adults with poor mobility and high levels of comorbidity. To optimize the care of this population, early and repeat shared decision making conversations by health care providers, patients, and their families should consider the risks, burdens, and benefits of dialysis versus conservative management, as well as the patient specific symptoms and clinical situations that could justify dialysis initiation. The potential advantages and disadvantages of dialysis therapy should be considered in conjunction with each patient's unique goals and priorities.In conclusion, when considering the morbidity and quality of life impact associated with dialysis, many older adults may prefer to delay dialysis until there is a definitive indication or may opt for conservative management without dialysis. This approach can incorporate all CKD treatments other than dialysis, provide psychosocial and spiritual support and active symptom management and may also incorporate a palliative care approach with less medical monitoring of lab parameters and more focus on the use of drug therapies directed to relief of a patient's symptoms.
Krieg, J; Koenzen, E; Seifried, N; Steingass, H; Schenkel, H; Rodehutscord, M
2018-03-01
Ruminal in situ incubations are widely used to assess the nutritional value of feedstuffs for ruminants. In in situ methods, feed samples are ruminally incubated in indigestible bags over a predefined timespan and the disappearance of nutrients from the bags is recorded. To describe the degradation of specific nutrients, information on the concentration of feed samples and undegraded feed after in situ incubation ('bag residues') is needed. For cereal and pea grains, CP and starch (ST) analyses are of interest. The numerous analyses of residues following ruminal incubation contribute greatly to the substantial investments in labour and money, and faster methods would be beneficial. Therefore, calibrations were developed to estimate CP and ST concentrations in grains and bag residues following in situ incubations by using their near-infrared spectra recorded from 680 to 2500 nm. The samples comprised rye, triticale, barley, wheat, and maize grains (20 genotypes each), and 15 durum wheat and 13 pea grains. In addition, residues after ruminal incubation were included (at least from four samples per species for various incubation times). To establish CP and ST calibrations, 620 and 610 samples (grains and bag residues after incubation, respectively) were chemically analysed for their CP and ST concentration. Calibrations using wavelengths from 1250 to 2450 nm and the first derivative of the spectra produced the best results (R 2 Validation=0.99 for CP and ST; standard error of prediction=0.47 and 2.10% DM for CP and ST, respectively). Hence, CP and ST concentration in cereal grains and peas and their bag residues could be predicted with high precision by NIRS for use in in situ studies. No differences were found between the effective ruminal degradation calculated from NIRS estimations and those calculated from chemical analyses (P>0.70). Calibrations were also calculated to predict ruminal degradation kinetics of cereal grains from the spectra of ground grains. Estimation of the effective ruminal degradation of CP and ST from the near-infrared spectra of cereal grains showed promising results (R 2>0.90), but the database needs to be extended to obtain more stable calibrations for routine use.
Impact of storage environment on the efficacy of hermetic storage bags.
Lane, Brett; Woloshuk, Charles
2017-05-01
Small hermetic bags (50 and 100 kg capacities) used by smallholder farmers in several African countries have proven to be a low-cost solution for preventing storage losses due to insects. The complexity of postharvest practices and the need for ideal drying conditions, especially in the Sub-Sahara, has led to questions about the efficacy of the hermetic bags for controlling spoilage by fungi and the potential for mycotoxin accumulation. This study compared the effects of environmental temperature and relative humidity at two locations (Indiana and Arkansas) on dry maize (14% moisture content) in woven polypropylene bags and Purdue Improved Crop Storage (PICS) hermetic bags. Temperature and relative humidity data loggers placed in the middle of each bag provided profiles of environmental influences on stored grain at the two locations. The results indicated that the PICS bags prevented moisture penetration over the three-month storage period. In contrast, maize in the woven bags increased in moisture content. For both bag types, no evidence was obtained indicating the spread of Aspergillus flavus from colonized maize to adjacent non-colonized maize. However, other storage fungi did increase during storage. The number of infected kernels did not increase in the PICS bags, but the numbers in the woven bags increased significantly. The warmer environment in Arkansas resulted in significantly higher insect populations in the woven bags than in Indiana. Insects in the PICS bags remained low at both locations. This study demonstrates that the PICS hermetic bags are effective at blocking the effects of external humidity fluctuations as well as the spread of fungi to non-infected kernels.
Performance comparison of plastic shopping bags in modern and traditional retail
NASA Astrophysics Data System (ADS)
Radini, F. A.; Wulandari, R.; Nasiri, S. J. A.; Winarto, D. A.
2017-07-01
Followed by implementation of paid plastic bag policy in Indonesia’s modern and traditional retail, community question related to plastic shopping bag performance arise. But, there is limited information about it. Therefore, the assessment of the performance to compare between plastic shopping bags in modern retail and traditional retail should be interesting. The observation performance of plastic shopping bag were weight holding capacity, tear resistant and elongation. This performance were tested using Universal Testing Machine. Physical and physico-chemical properties also identified to determine factor affecting the performance of plastic shopping bag. The physical properties were analysed using visual and thickness gauge to see the colour and measure the thickness. The analysis of physico-chemical properties were carried out using DSC (Differential Scanning Calorimetry), TGA (Thermal Gravimetry Analysis), Furnace and FTIR (Fourier Transform Infra Red Spectroscopy) to identify the materials, also its melting and decomposition temperature. The result showed that the performance difference between modern retail plastic bag with traditional retail plastic bag appears only in the performance of elongation. The elongation of modern retail plastic bag is 121 - 413%, while traditional has 170 - 609%. According to physico-chemical test result, modern retail and traditional retail plastic bag contain polyethylene as main material and has melting temperature in the range of High Density Polyethylene (HDPE) melting temperature. However, modern retail plastic bag has 18.31 - 33.87% of inorganic filler percentage, whereas the traditional retail plastic bag has 0.35 - 9.85%. This inorganic filler percentage probably a contributing factor in the elongation performance difference between modern retail plastic bag with traditional retail plastic bag.
Chen, Ying; Yang, Li-Na; Cheng, Li; Tu, Shun; Guo, Shu-Juan; Le, Huang-Ying; Xiong, Qian; Mo, Ran; Li, Chong-Yang; Jeong, Jun-Seop; Jiang, Lizhi; Blackshaw, Seth; Bi, Li-Jun; Zhu, Heng; Tao, Sheng-Ce; Ge, Feng
2013-01-01
Bcl2-associated athanogene 3 (BAG3), a member of the BAG family of co-chaperones, plays a critical role in regulating apoptosis, development, cell motility, autophagy, and tumor metastasis and in mediating cell adaptive responses to stressful stimuli. BAG3 carries a BAG domain, a WW domain, and a proline-rich repeat (PXXP), all of which mediate binding to different partners. To elucidate BAG3's interaction network at the molecular level, we employed quantitative immunoprecipitation combined with knockdown and human proteome microarrays to comprehensively profile the BAG3 interactome in humans. We identified a total of 382 BAG3-interacting proteins with diverse functions, including transferase activity, nucleic acid binding, transcription factors, proteases, and chaperones, suggesting that BAG3 is a critical regulator of diverse cellular functions. In addition, we characterized interactions between BAG3 and some of its newly identified partners in greater detail. In particular, bioinformatic analysis revealed that the BAG3 interactome is strongly enriched in proteins functioning within the proteasome-ubiquitination process and that compose the proteasome complex itself, suggesting that a critical biological function of BAG3 is associated with the proteasome. Functional studies demonstrated that BAG3 indeed interacts with the proteasome and modulates its activity, sustaining cell survival and underlying resistance to therapy through the down-modulation of apoptosis. Taken as a whole, this study expands our knowledge of the BAG3 interactome, provides a valuable resource for understanding how BAG3 affects different cellular functions, and demonstrates that biologically relevant data can be harvested using this kind of integrated approach. PMID:23824909
Serrano, K; Levin, E; Chen, D; Hansen, A; Turner, T R; Kurach, J; Reidel, A; Boecker, W F; Acker, J P; Devine, D V
2016-04-01
Di-2-ethylhexyl phthalate (DEHP) is a blood bag plasticizer. It is also a toxin, raising concerns for vulnerable populations, for example, neonates and infants. Here, the in vitro quality of red cell concentrates (RCC) stored in paediatric bags formulated with alternative plasticizers to DEHP was compared. RCC were pooled and split into polyvinylchloride (PVC)/DEHP, PVC/1,2-cyclohexanedicarboxylic acid diisononyl ester (DINCH) or PVC/butyryl trihexyl citrate (BTHC) bags. Quality was assessed on storage days 5, 21, 35 and 43. Metabolism differed among the bags: pCO2 levels were lowest and pO2 were highest in BTHC bags. Glucose consumption and lactate production suggested higher metabolic rates in BTHC bags. ATP levels were best maintained in DINCH bags (day 43 mean level: 2·86 ± 0·29 μmol/g Hb). RCC in BTHC bags had the greatest potassium release (54·6 ± 3·0 mm on day 43). From day 21, haemolysis was higher in BTHC bags (P < 0·01) and by day 43 had exceeded 0·8% (0·85 ± 0·10%). RCC in BTHC bags showed more microparticle formation than RCC in DEHP or DINCH bags. The results suggest that the BTHC formulation used was detrimental to RBC quality. DINCH bags could be a viable alternative to DEHP: they outperformed DEHP bags energetically, with better maintenance of ATP levels. © 2015 International Society of Blood Transfusion.
Kikuta, A; Ohto, H; Nemoto, K; Mochizuki, K; Sano, H; Ito, M; Suzuki, H
2006-07-01
Granulocyte transfusion therapy (GTX) can be effective for life-threatening infections unresponsive to conventional antimicrobial therapies in severely neutropenic children with cancer. We developed a new granulocyte collection method, named the 'bag method', in which apheresis, hydroxyethyl starch (HES) or dexamethasone are not used. We undertook a pilot study to determine the feasibility and the safety of GTX collected by the bag method for children with cancer and life-threatening infections. A total of 25 GTX were administered to 13 patients (median age 3 years, range: 0.3-17; median weight 10.6 kg, range: 4.5-49.8) with neutropenia-related infections. Thirteen blood-relative donors received granulocyte colony-stimulating factor (G-CSF) (5-10 microg/kg), subcutaneously, 14 h before collection. Major end-points were granulocyte yields, post-transfusion absolute neutrophil counts (ANC) in patients, donor and patient safety, and clinical outcome on day 30. The median yield of ANC per 400 ml of processed whole blood was 6.2 x 10(9) (range: 2.5-15.0 x 10(9)). Patients received a mean of 6.4 +/- 0.8 x 10(8) granulocytes per kg of body weight per transfusion. The 1-h and 24-h post-transfusion ANC rose to 607 +/- 124/microl and 704 +/- 300/microl, respectively, from the baseline of 21/microl before the first GTX. Adverse reactions were observed in five of 13 donors (bone pain, headache, vasovagal reaction; all < or = grade 2) and in two of 25 transfusions of 13 patients (transient hypoxia; grade 3). Ten patients had favourable responses, and infection resolved in nine patients. The bag method without apheresis relieves the physical load of donors and enables patients with a low body weight to provide an adequate dose of granulocytes.
2012-07-01
Composites 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Larry R. Holmes, Jr., James P. Wolbert, and Jared M...greater than 10 kPa (1.5 psi) pressure change in the vacuum bag. A redundant second vacuum bag was applied over the entire layup to further protect...In order to maintain the increased fvf and decrease the processing time, a second experimental process was conducted using a compacted and pre
The Use of a Multidimensional Measure of Dialysis Adequacy—Moving beyond Small Solute Kinetics
Perl, Jeffrey; Dember, Laura M.; Bargman, Joanne M.; Browne, Teri; Charytan, David M.; Flythe, Jennifer E.; Hickson, LaTonya J.; Hung, Adriana M.; Jadoul, Michel; Lee, Timmy Chang; Meyer, Klemens B.; Moradi, Hamid; Shafi, Tariq; Teitelbaum, Isaac; Wong, Leslie P.
2017-01-01
Urea removal has become a key measure of the intensity of dialysis treatment for kidney failure. Small solute removal, exemplified by Kt/Vurea, has been broadly applied as a means to quantify the dose of thrice weekly hemodialysis. Yet, the reliance on small solute clearances alone as a measure of dialysis adequacy fails fully to quantify the intended clinical effects of dialysis therapy. This review aims to (1) understand the strengths and limitations of small solute kinetics as a surrogate marker of dialysis dose, and (2) present the prospect of a more comprehensive construct for dialysis dose, one that considers more broadly the goals of ESRD care to maximize both quality of life and survival. On behalf of the American Society of Nephrology Dialysis Advisory Group, we propose the need to ascertain the validity and utility of a multidimensional measure that moves beyond small solute kinetics alone to quantify optimal dialysis derived from both patient-reported and comprehensive clinical and dialysis-related measures. PMID:28314806
The new standard of fluids for hemodialysis in Japan.
Kawanishi, Hideki; Masakane, Ikuto; Tomo, Tadashi
2009-01-01
The standard of fluids for hemodialysis is being evaluated by the International Organization for Standardization (ISO), and will be decided within a few years. In 2008, the Japanese Society for Dialysis Therapy (JSDT) proposed the standard of fluids for hemodialysis by taking the draft ISO standard into consideration and the circumstances in Japan. It was characteristically a standard for Japan, where the central dialysis fluid delivery system (CDDS) is routinely used. In addition, the therapeutic application of each dialysis fluid is clarified. Since high-performance dialyzers are frequently employed in Japan, the standard recommends that ultrapure dialysis fluid be used for all dialysis modalities at all dialysis facilities. It also recommends that the dialysis equipment safety management committee at each facility validate the microbiological qualities of online-prepared substitution fluid, making the responsibility of the dialysis facility clear. This standard is more rigid than those of other countries, and is expected to contribute to improvements in the survival outcome of dialysis patients. (c) 2009 S. Karger AG, Basel.
Hanselman, Travis A; Graetz, Donald A; Obreza, Thomas A
2004-01-01
In situ incubation methods may help provide site-specific estimates of N mineralization from land-applied wastes. However, there are concerns about the reliability of the data generated by the various methods due to containment artifacts. We amended a sandy soil with either poultry manure, biosolids, or yard-waste compost and incubated the mixtures using four in situ methods (buried bags, covered cylinders, standard resin traps, and "new" soil-resin traps) and a conventional laboratory technique in plastic bags. Each incubation device was destructively sampled at 45-d intervals for 180 d and net N mineralization was determined by measuring the amount of inorganic N that accumulated in the soil or soil plus resin traps. Containment effects were evaluated by comparing water content of the containerized soil to a field-reference soil column. In situ incubation methods provided reasonable estimates of short-term (< 45 d) N mineralization, but long-term (> 45 d) mineralization data were not accurate due to a variety of problems specific to each technique. Buried bags and covered cylinders did not retain mineralized N due to water movement into and out of the containers. Neither resin method captured all of the mineralized N that leached through the soil columns, but the new soil-resin trap method tracked field soil water content better than all other in situ methods evaluated. With further refinement and validation, the new soil-resin trap method may be a useful in situ incubation technique for measuring net N mineralization rates of organic soil amendments.
Stein, J D; Jaeger, E A; Jeffers, J B
1999-01-01
PURPOSE: This investigation retrospectively examined ocular injuries associated with air bag deployment to gain a better appreciation of potential risk factors in motor vehicle accidents. National statistics regarding the efficacy of air bags were reviewed. METHODS: Review of the literature from 1991 to 1998 identified 44 articles describing 97 patients with air-bag-induced ocular injuries. Variables extracted from each case were age, sex, height, position in the car, eye wear, vehicle impact speed, visual acuity, and specific ocular injuries. RESULTS: Corneal abrasions occurred in 49% of occupants, hyphemas in 43%, vitreous or retinal hemorrhages in 25%, and retinal tears or detachments in 15%. The globe was ruptured in 10 patients. Patients involved in higher-speed accidents (over 30 mph) sustained a greater percentage of vitreous or retinal hemorrhages and traumatic cataracts, while those at slower speeds were more prone to retinal tears or detachments. In a subset of 14 patients with serious ocular injuries, the impact speed of 11 patients was recorded at 30 mph or less. Slower speed may be a risk factor for some ocular injuries. Occupant height was not a significant factor. National statistics confirm that air bags reduce fatalities in motor vehicle accidents. However, children sitting in the front seat without a seat belt and infants in passenger-side rear-facing car seats are at risk for fatal injury. CONCLUSION: Air bags combined with seat belts are an effective means of reducing injury and death in adults during motor vehicle accidents. However, this study has documented a wide variety of ocular injuries associated with air bag deployment. It is hoped that researchers can develop modifications that continue to save lives while minimizing additional harm. Images FIGURE 1 FIGURE 2A FIGURE 2B FIGURE 2C FIGURE 2D FIGURE 3A FIGURE 3B FIGURE 4 FIGURE 5 FIGURE 7 FIGURE 8 PMID:10703118
Khoo, Lay See; Lai, Poh Soon; Saidin, Mohd Hilmi; Noor, Zahari; Mahmood, Mohd Shah
2018-07-01
Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later. Copyright © 2018 Elsevier B.V. All rights reserved.
Khoo, Lay See; Lai, Poh Soon; Saidin, Mohd Hilmi; Noor, Zahari; Mahmood, Mohd Shah
2018-04-01
Cadaver body bags are the conventional method to contain a human body or human remains, which includes the use for storage and transportation of the deceased at any crime scene or disaster scene. During disasters, most often than not, the first responders including the police will be equipped with cadaver body bags to do scene processing of human remains and collection of personal belongings at the disaster site. However, in an unanticipated large scale disasters involving hundreds and thousands of fatalities, cadaver body bags supplies may be scarce. The authors have therefore innovated the cling film plastic wrap as an alternative for the cadaver body bag used at the disaster site. The plastic wrap was tested on six different experimental subjects, i.e. both adult and child mannequins; body parts of the mannequin figure (arm and hand); a human adult subject and an unknown dead body. The strengths of the cling film plastic wrap are discussed in comparison with the cadaver body bag in the aspects of costing, weight, duration of the wrap, water and body fluid resistant properties, visibility and other advantages. An average savings of more than 5000% are noted for both adult body wrap and child body wrap compared to the cadaver body wrap. This simply means that the authors can either wrap 25 adult dead bodies or 80 children dead bodies with the cost of 1 cadaver body bag. The cling film plastic wrap has proven to have significant innovation impact for dead body management particularly by the first responders in large scale disasters. With proper handling of dead bodies, first responders can manage the dead with dignity and respect in an overwhelmed situation to facilitate the humanitarian victim identification process later. Copyright © 2018 Elsevier B.V. All rights reserved.
Plastic Bags for Prevention of Hypothermia in Preterm and Low Birth Weight Infants
Leadford, Alicia E.; Warren, Jamie B.; Manasyan, Albert; Chomba, Elwyn; Salas, Ariel A.; Schelonka, Robert
2013-01-01
BACKGROUND AND OBJECTIVES: Hypothermia contributes to neonatal mortality and morbidity, especially in preterm and low birth weight infants in developing countries. Plastic bags covering the trunk and extremities of very low birth weight infants reduces hypothermia. This technique has not been studied in larger infants or in many resource-limited settings. The objective was to determine if placing preterm and low birth weight infants inside a plastic bag at birth maintains normothermia. METHODS: Infants at 26 to 36 weeks’ gestational age and/or with a birth weight of 1000 to 2500 g born at the University Teaching Hospital in Lusaka, Zambia, were randomized by using a 1:1 allocation and parallel design to standard thermoregulation (blanket or radiant warmer) care or to standard thermoregulation care plus placement inside a plastic bag at birth. The primary outcome measure was axillary temperature in the World Health Organization–defined normal range (36.5–37.5°C) at 1 hour after birth. RESULTS: A total of 104 infants were randomized. At 1 hour after birth, infants randomized to plastic bag (n = 49) were more likely to have a temperature in the normal range as compared with infants in the standard thermoregulation care group (n = 55; 59.2% vs 32.7%; relative risk 1.81; 95% confidence interval 1.16–2.81; P = .007). The temperature at 1 hour after birth in the infants randomized to plastic bag was 36.5 ± 0.5°C compared with 36.1 ± 0.6°C in standard care infants (P < .001). Hyperthermia (>38.0°C) did not occur in any infant. CONCLUSIONS: Placement of preterm/low birth weight infants inside a plastic bag at birth compared with standard thermoregulation care reduced hypothermia without resulting in hyperthermia, and is a low-cost, low-technology tool for resource-limited settings. PMID:23733796
Absolute and Relative Carnitine Deficiency in Patients on Hemodialysis and Peritoneal Dialysis.
Naseri, Mitra; Mottaghi Moghadam Shahri, Hasan; Horri, Mohsen; Esmaeeli, Mohammad; Ghaneh Sherbaf, Fatemeh; Jahanshahi, Shohre; Moeenolroayaa, Giti; Rasoli, Zahra; Salemian, Farzaneh; Pour Hasan, Maryam
2016-01-01
Carnitine deficiency is commonly seen in dialysis patients. This study assessed the association dialysis and pediatric patients' characteristics with plasma carnitines levels. Plasma carnitine concentrations were measured by tandem mass spectrometry in 46 children on hemodialysis or peritoneal dialysis. The total carnitine, free carnitine (FC), and L-acyl carnitine (AC) levels of 40 µmol/L and less, less than 7 µmol/L, and less than 15 µmol/L were defined low, respectively. An FC less than 20 µmol/L and an AC/FC ratio greater than 0.4 were considered as absolute and relative carnitine deficiencies. The correlation between carnitines levels and AC/FC ratio and age, duration of dialysis, characteristics of dialysis, and blood urea nitrogen and serum albumin concentrations were assessed. Absolute carnitine deficiency, low total carnitine, and low AC concentrations were found in 66.7%, 82.6%, and 51% of the patients, respectively. All of the patients had relative carnitine deficiency. Carnitine measurements were not significantly different between the hemodialysis and peritoneal dialysis groups. More severe relative carnitine deficiency was found in those with lower blood urea nitrogen levels and those on peritoneal dialysis. No linear correlation was found between carnitine levels and age, duration of dialysis, characteristics of dialysis, serum albumin level, or blood urea nitrogen level. Absolute and relative carnitine deficiencies are common among children on dialysis. Patients with lower blood urea nitrogen levels and peritoneal dialysis patients are more prone to severe relative carnitine deficiency.
Janmaat, Cynthia J; van Diepen, Merel; Krediet, Raymond T; Hemmelder, Marc H; Dekker, Friedo W
2017-01-01
Purpose Current clinical guidelines recommend to initiate dialysis in the presence of symptoms or signs attributable to kidney failure, often with a glomerular filtration rate (GFR) of 5–10 mL/min/1.73 m2. Little evidence exists about the optimal kidney function to start dialysis. Thus far, most observational studies have been limited by lead-time bias. Only a few studies have accounted for lead-time bias, and showed contradictory results. We examined the effect of GFR at dialysis initiation on survival in chronic kidney disease patients, and the role of lead-time bias therein. We used both kidney function based on 24-hour urine collection (measured GFR [mGFR]) and estimated GFR (eGFR). Materials and methods A total of 1,143 patients with eGFR data at dialysis initiation and 852 patients with mGFR data were included from the NECOSAD cohort. Cox regression was used to adjust for potential confounders. To examine the effect of lead-time bias, survival was counted from the time of dialysis initiation or from a common starting point (GFR 20 mL/min/1.73 m2), using linear interpolation models. Results Without lead-time correction, no difference between early and late starters was present based on eGFR (hazard ratio [HR] 1.03, 95% confidence interval [CI] 0.81–1.3). However, after lead-time correction, early initiation showed a survival disadvantage (HR between 1.1 [95% CI 0.82–1.48] and 1.33 [95% CI 1.05–1.68]). Based on mGFR, the potential survival benefit for early starters without lead-time correction (HR 0.8, 95% CI 0.62–1.03) completely disappeared after lead-time correction (HR between 0.94 [95% CI 0.65–1.34] and 1.21 [95% CI 0.95–1.56]). Dialysis start time differed about a year between early and late initiation. Conclusion Lead-time bias is not only a methodological problem but also has clinical impact when assessing the optimal kidney function to start dialysis. Therefore, lead-time bias is extremely important to correct for. Taking account of lead-time bias, this controlled study showed that early dialysis initiation (eGFR >7.9, mGFR >6.6 mL/min/1.73 m2) was not associated with an improvement in survival. Based on kidney function, this study suggests that in some patients, dialysis could be started even later than an eGFR <5.7 and mGFR <4.3 mL/min/1.73 m2. PMID:28442934
Reduction of plastic carrier bag use: An analysis of alternatives in Israel.
Ayalon, Ofira; Goldrath, Tal; Rosenthal, Gad; Grossman, Michal
2009-07-01
Plastic carrier bags have been drawing the attention of the public and politicians. Different policy measures to reduce the environmental burden of these bags have been implemented and more are planned. The research analyzed the actual environmental aspects of consumption and use of plastic carrier bags and assessed the effectiveness of the proposed regulation in Israel. Since plastic bags are provided free of charge, people have a tendency to use these bags excessively, therefore a rigorous educational program should address this trend. However, the environmental load imposed by the bags is more a politically correct issue than an actual environmental hazard, and therefore the means for reducing their use should not include a high levy or total elimination of these bags.
Comparison of cryopreservation bags for hematopoietic progenitor cells using a WBC-enriched product.
Dijkstra-Tiekstra, Margriet J; Hazelaar, Sandra; Gkoumassi, Effimia; Weggemans, Margienus; de Wildt-Eggen, Janny
2015-04-01
Hematopoietic progenitor cells (HPC) are stored in cryopreservation bags that are resistant to liquid nitrogen. Since Cryocyte bags of Baxter (B-bags) are no longer available, an alternative bag was sought. Also, the influence of freezing volume was studied. Miltenyi Biotec (MB)- and MacoPharma (MP)-bags passed the integrity tests without failure. Comparing MB- and MP-bags with B-bags, no difference in WBC recovery or viability was found when using a WBC-enriched product as a "dummy" HPC product. Further, a freezing volume of 30 mL resulted in better WBC recovery and viability than 60 mL. Additonal studies using real HPC might be necessary. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ghosh, Samik; Kim, Ki-Hyun; Sohn, Jong Ryeul
2011-01-01
In this study, we have examined the patterns of VOCs released from used Tedlar bags that were once used for the collection under strong source activities. In this way, we attempted to account for the possible bias associated with the repetitive use of Tedlar bags. To this end, we selected the bags that were never heated. All of these target bags were used in ambient temperature (typically at or below 30°C). These bags were also dealt carefully to avoid any mechanical abrasion. This study will provide the essential information regarding the interaction between VOCs and Tedlar bag materials as a potential source of bias in bag sampling approaches. PMID:22235175
Ghosh, Samik; Kim, Ki-Hyun; Sohn, Jong Ryeul
2011-01-01
In this study, we have examined the patterns of VOCs released from used Tedlar bags that were once used for the collection under strong source activities. In this way, we attempted to account for the possible bias associated with the repetitive use of Tedlar bags. To this end, we selected the bags that were never heated. All of these target bags were used in ambient temperature (typically at or below 30°C). These bags were also dealt carefully to avoid any mechanical abrasion. This study will provide the essential information regarding the interaction between VOCs and Tedlar bag materials as a potential source of bias in bag sampling approaches.
Legitimization of regulatory norms: Waterfowl hunter acceptance of changing duck bag limits
Schroeder, Susan A.; Fulton, David C.; Lawrence, Jeffrey S.; Cordts, Steven D.
2014-01-01
Few studies have examined response to regulatory change over time, or addressed hunter attitudes about changes in hunting bag limits. This article explores Minnesota waterfowl hunters’ attitudes about duck bag limits, examining attitudes about two state duck bag limits that were initially more restrictive than the maximum set by the U.S. Fish and Wildlife Service (USFWS), but then increased to match federal limits. Results are from four mail surveys that examined attitudes about bag limits over time. Following two bag limit increases, a greater proportion of hunters rated the new bag limit “too high” and a smaller proportion rated it “too low.” Several years following the first bag limit increase, the proportion of hunters who indicated that the limit was “too high” had declined, suggesting hunter acceptance of the new regulation. Results suggest that waterfowl bag limits may represent legal norms that influence hunter attitudes and gain legitimacy over time.
Silencing of BAG3 inhibits the epithelial-mesenchymal transition in human cervical cancer.
Song, Fei; Wang, Geng; Ma, Zhifang; Ma, Yuebing; Wang, Yingying
2017-11-10
Bcl2-associated athanogene 3 (BAG3) has been reported to be involved in aggressive progression of many tumors. In the present study, we examined the expression of BAG3 in human cervical cancer (CC) tissues and investigated the role of BAG3 in SiHa and HeLa cell growth, migration, and invasion. Here, we found that most of CC tissues highly expressed the protein and mRNA of BAG3, while their expression was obviously lower in paired normal tissues (all p<0.001). BAG3 expression was associated with FIGO stage and metastasis (all p<0.05). In-vitro analysis demonstrated that BAG3 siRNAs inhibited SiHa and HeLa cell growth, invasion and migration. Mechanically, BAG3 siRNAs inhibited the expression of EMT-regulating markers, involving MMP2, Slug and N-cadherin, and increased the expression of E-cadherin. In a xenograft nude model, BAG3 siRNAs inhibited tumor growth and the expression of EMT biomarkers. In conclusion, BAG3 is involved in the EMT process, including cell growth, invasion and migration in the development of CC. Thus, BAG3 target might be recommended as a novel therapeutic approach.
Silencing of BAG3 inhibits the epithelial-mesenchymal transition in human cervical cancer
Song, Fei; Wang, Geng; Ma, Zhifang; Ma, Yuebing; Wang, Yingying
2017-01-01
Bcl2-associated athanogene 3 (BAG3) has been reported to be involved in aggressive progression of many tumors. In the present study, we examined the expression of BAG3 in human cervical cancer (CC) tissues and investigated the role of BAG3 in SiHa and HeLa cell growth, migration, and invasion. Here, we found that most of CC tissues highly expressed the protein and mRNA of BAG3, while their expression was obviously lower in paired normal tissues (all p<0.001). BAG3 expression was associated with FIGO stage and metastasis (all p<0.05). In-vitro analysis demonstrated that BAG3 siRNAs inhibited SiHa and HeLa cell growth, invasion and migration. Mechanically, BAG3 siRNAs inhibited the expression of EMT-regulating markers, involving MMP2, Slug and N-cadherin, and increased the expression of E-cadherin. In a xenograft nude model, BAG3 siRNAs inhibited tumor growth and the expression of EMT biomarkers. In conclusion, BAG3 is involved in the EMT process, including cell growth, invasion and migration in the development of CC. Thus, BAG3 target might be recommended as a novel therapeutic approach. PMID:29221135
Bagworm bags as portable armour against invertebrate predators
2016-01-01
Some animals have evolved the use of environmental materials as “portable armour” against natural enemies. Portable bags that bagworm larvae (Lepidoptera: Psychidae) construct using their own silk and plant parts are generally believed to play an important role as a physical barrier against natural enemies. However, no experimental studies have tested the importance of bags as portable armour against predators. To clarify the defensive function, I studied the bagworm Eumeta minuscula and a potential predator Calosoma maximoviczi (Coleoptera: Carabidae). Under laboratory conditions, all bagworm larvae were attacked by carabid adults, but successfully defended themselves against the predators’ mandibles using their own bags. The portable bags, which are composed mainly of host plant twigs, may function as a physical barrier against predator mandibles. To test this hypothesis, I removed the twig bags and replaced some with herb leaf bags; all bag-removed larvae were easily caught and predated by carabids, while all bag-replaced larvae could successfully defend themselves against carabid attacks. Therefore, various types of portable bags can protect bagworm larvae from carabid attacks. This is the first study to test the defensive function of bagworm portable bags against invertebrate predators. PMID:26893969
Warming preterm infants in the delivery room: polyethylene bags, exothermic mattresses or both?
McCarthy, Lisa K; O'Donnell, Colm P F
2011-12-01
To compare the admission temperature of infants treated with polyethylene bags alone to infants treated with exothermic mattresses in addition to bags in the delivery room. We prospectively studied infants born at <31 weeks' gestation who were placed in bags at birth. Some infants were also placed on mattresses. Admission axillary temperatures were measured in all infants on admission to the neonatal intensive care. We compared the temperatures of infants treated with bags alone to those treated with mattresses and bags. We studied 43 infants: 15 were treated with bags while 28 were treated with a bag and mattress. Mean admission temperature was similar between the groups. Hypothermia and hyperthermia occurred more frequently in infants treated with a bag and mattress, and more infants treated with a bag had admission temperatures 36.5-37.5°C. The use of exothermic mattresses in addition to polyethylene bags, particularly in younger, smaller newborns, may result in more hypothermia and hyperthermia on admission. A randomised controlled trial is necessary to determine which strategy results in more infants having admission temperatures in the normal range. © 2011 The Author(s)/Acta Paediatrica © 2011 Foundation Acta Paediatrica.
High expression of BAG3 predicts a poor prognosis in human medulloblastoma.
Yang, Dong; Zhou, Ji; Wang, Hao; Wang, Yutao; Yang, Ge; Zhang, Yundong
2016-10-01
Bcl2-associated athanogene 3 (BAG3), a co-chaperone of the heat shock protein (Hsp) 70, regulates various physiological and pathological processes. However, its role in human medulloblastoma has not been clarified. First of all, the expression of BAG3 was examined in formalin-fixed, paraffin-embedded specimens by immunohistochemical staining. And then, the prognostic role of BAG3 was analyzed in 51 medulloblastoma samples. Finally, the roles of BAG3 in the proliferation, migration, and invasion of Daoy medulloblastoma cell were investigated using a specific short hairpin RNA (shRNA). The expression of BAG3 in medulloblastoma tissues was higher than nontumorous samples. Furthermore, BAG3 overexpression significantly correlated with poor prognosis of patients with medulloblastoma. The overall survival and tumor-free survival in patients with BAG3 low expression were higher than high expression. Univariate and multivariate analysis showed that BAG3 overexpression was an independent prognostic marker for medulloblastoma. After the BAG3 knockdown, the Daoy cells exhibited decreased the ability to proliferate and form neurosphere. The preliminary mechanism study showed that overexpression of BAG3 might facilitate the cell cycle transition from G1 to S phase by modulating the cyclin-dependent kinase 2 (CDK2) and cyclin E expression. Additionally, we found that BAG3 might enhance the medulloblastoma cell migratory and invasive ability. In summary, BAG3 overexpression may regulate the survival and invasive properties of medulloblastoma and may serve as a potential therapy target for medulloblastoma.
BAG3: a multifaceted protein that regulates major cell pathways
Rosati, A; Graziano, V; De Laurenzi, V; Pascale, M; Turco, M C
2011-01-01
Bcl2-associated athanogene 3 (BAG3) protein is a member of BAG family of co-chaperones that interacts with the ATPase domain of the heat shock protein (Hsp) 70 through BAG domain (110–124 amino acids). BAG3 is the only member of the family to be induced by stressful stimuli, mainly through the activity of heat shock factor 1 on bag3 gene promoter. In addition to the BAG domain, BAG3 contains also a WW domain and a proline-rich (PXXP) repeat, that mediate binding to partners different from Hsp70. These multifaceted interactions underlie BAG3 ability to modulate major biological processes, that is, apoptosis, development, cytoskeleton organization and autophagy, thereby mediating cell adaptive responses to stressful stimuli. In normal cells, BAG3 is constitutively present in a very few cell types, including cardiomyocytes and skeletal muscle cells, in which the protein appears to contribute to cell resistance to mechanical stress. A growing body of evidence indicate that BAG3 is instead expressed in several tumor types. In different tumor contexts, BAG3 protein was reported to sustain cell survival, resistance to therapy, and/or motility and metastatization. In some tumor types, down-modulation of BAG3 levels was shown, as a proof-of-principle, to inhibit neoplastic cell growth in animal models. This review attempts to outline the emerging mechanisms that can underlie some of the biological activities of the protein, focusing on implications in tumor progression. PMID:21472004
[Expression of BAG3 Gene in Acute Myeloid Leukemia and Its Prognostic Value].
Zhu, Hua-Yuan; Fu, Yuan; Wu, Wei; Xu, Jia-Dai; Chen, Ting-Mei; Qiao, Chun; Li, Jian-Yong; Liu, Peng
2015-08-01
To investigate the expression of BAG3 gene in acue myeloid leukemia (AML) and its prognostic value. Real-time quantitative RT-PCR was used to detect the expression of BAG3 mRNA in 88 previously untreated AML patients. The corelation of BAG3 expression level with clinical characteristics and known prognostic markers of AML was analyzed. In 88 patients with AML, the expression of BAG3 mRNA in NPMI mutated AML patients was obviously lower than that in NPMI unmutated patients (P = 0.018). The expression level of BAG3 mRNA did not related to clinical parameters, such as age, sex, FAB subtype, WBC count, extra-modullary presentation, and to prognostic factors including cytogenetics, FLT3-ITD, c-kit and CEBPα mutation status (P > 0.05). The expression level of BAG3 had no obvious effect on complete remission (CR) of patients in first treatment. The expression level of BAG3 in non-M3 patients was higher than that in relapsed patients (P = 0.036). The expression level of BAG3 had no effect on overall survival (OS) of patients. The expression level of BAG3 does not correlated with known-prognostic markers of AML, only the expression level of BAG3 in NPM1 mutated patients is lower than that in NPM1 unmutated patients. The expression level of BAG3 has no effect on OS of AML patients, the BAG3 can not be difined as a prognostic marker in AML.
Mixing of two solutions combined by gravity drainage.
Leuptow, R M; Smith, K; Mockros, L F
1995-01-01
A variety of medical therapies require the mixing of solutions from two separate bags before use. One scenario for the mixing is to drain the solution from one bag into the other by gravity through a short connecting tube. The degree of mixing in the lower bag depends on the relative densities of the two solutions, the geometry of the two bags and the connecting tube, and the placement of the connecting tube. Solutions with densities differing by as much as 12% were mixed by draining the solution from an upper bag into a lower bag for a particular geometric configuration. The two solutions had different electrical conductivities, and the conductivity of the combined solution as it exited from the lower bag was used as a measure of the effectiveness of mixing. When the more dense solution was drained from the upper bag into the less dense solution in a lower bag, mixing was very effective. The incoming jet of high density solution entrained the low density solution. Flow visualization indicated that the incoming jet penetrated to the bottom of the lower bag, and resulting large vortical structures enhanced mixing. When the less dense solution was drained from the upper bag into the more dense solution in the lower bag mixing was less effective. The buoyancy force reduced the momentum of the incoming jet such that it did not penetrate to the bottom of the lower bag, resulting in stratification of the solutions.
Cesium sorption reversibility and kinetics on illite, montmorillonite, and kaolinite
Durrant, Chad B.; Begg, James D.; Kersting, Annie B.; ...
2017-08-17
Understanding sorption and desorption processes is essential to predicting the mobility of radionuclides in the environment. In this study, we investigate adsorption/desorption of cesium in both binary (Cs + one mineral) and ternary (Cs + two minerals) experiments to study component additivity and sorption reversibility over long time periods (500 days). Binary Cs sorption experiments were performed with illite, montmorillonite, and kaolinite in a 5 mM NaCl/0.7 mM NaHCO3 solution (pH 8) and Cs concentration range of 10 –3 to 10 –11 M. The binary sorption experiments were followed by batch desorption experiments. The sorption behavior was modeled with themore » FIT4FD code and the results used to predict desorption behavior. Sorption to montmorillonite and kaolinite was linear over the entire concentration range but sorption to illite was non-linear, indicating the presence of multiple sorption sites. Based on the 14 day batch desorption data, cesium sorption appeared irreversible at high surface loadings in the case of illite but reversible at all concentrations for montmorillonite and kaolinite. Additionally, a novel experimental approach, using a dialysis membrane, was adopted in the ternary experiments, allowing investigation of the effect of a second mineral on Cs desorption from the original mineral. Cs was first sorbed to illite, montmorillonite or kaolinite, then a 3.5–5 kDalton Float-A-Lyzer® dialysis bag with 0.3 g of illite was introduced to each experiment inducing desorption. Nearly complete Cs desorption from kaolinite and montmorillonite was observed over the experiment, consistent with our equilibrium model, indicating complete Cs desorption from these minerals. Results from the long-term ternary experiments show significantly greater Cs desorption compared to the binary desorption experiments. Approximately ~ 45% of Cs desorbed from illite. However, our equilibrium model predicted ~ 65% desorption. Importantly, the data imply that in some cases, slow desorption kinetics rather than permanent fixation may play an important role in apparent irreversible Cs sorption.« less
Chang, Tian-Ying; Zhang, Yi-Lin; Shan, Yan; Liu, Sai-Sai; Song, Xiao-Yue; Li, Zheng-Yan; Du, Li-Ping; Li, Yan-Yan; Gao, Douqing
2018-05-01
To examine whether the information-motivation-behavioural skills model could predict self-care behaviour among Chinese peritoneal dialysis patients. Peritoneal dialysis is a treatment performed by patients or their caregivers in their own home. It is important to implement theory-based projects to increase the self-care of patients with peritoneal dialysis. The information-motivation-behavioural model has been verified in diverse populations as a comprehensive, effective model to guide the design, implementation and evaluation of self-care programmes. A cross-sectional, observational study. A total of 201 adults with peritoneal dialysis were recruited at a 3A grade hospital in China. Participant data were collected on demographics, self-care information (knowledge), social support (social motivation), self-care attitude (personal motivation), self-efficacy (behaviour skills) and self-care behaviour. We also collected data on whether the recruited patients had peritoneal dialysis-associated peritonitis from electronic medical records. Measured variable path analysis was performed using mplus 7.4 to identify the information-motivation-behavioural model. Self-efficacy, information and social motivation predict peritoneal dialysis self-care behaviour directly. Information and personal support affect self-care behaviour through self-efficacy, whereas peritoneal dialysis self-care behaviour has a direct effect on the prevention of peritoneal dialysis-associated peritonitis. The information-motivation-behavioural model is an appropriate and applicable model to explain and predict the self-care behaviour of Chinese peritoneal dialysis patients. Poor self-care behaviour among peritoneal dialysis patients results in peritoneal dialysis-associated peritonitis. The findings suggest that self-care education programmes for peritoneal dialysis patients should include strategies based on the information-motivation-behavioural model to enhance knowledge, motivation and behaviour skills to change or maintain self-care behaviour. © 2018 John Wiley & Sons Ltd.
Janmaat, Cynthia J; van Diepen, Merel; van Hagen, Cheyenne Ce; Rotmans, Joris I; Dekker, Friedo W; Dekkers, Olaf M
2018-01-01
Substantial heterogeneity exists in reported kidney function decline in pre-dialysis chronic kidney disease (CKD). By design, kidney function decline can be studied in CKD 3-5 cohorts or dialysis-based studies. In the latter, patients are selected based on the fact that they initiated dialysis, possibly leading to an overestimation of the true underlying kidney function decline in the pre-dialysis period. We performed a systematic review and meta-analysis to compare the kidney function decline during pre-dialysis in CKD stage 3-5 patients, in these two different study types. We searched PubMed, EMBASE, Web of Science and Cochrane to identify eligible studies reporting an estimated glomerular filtration rate (eGFR) decline (mL/min/1.73 m 2 ) in adult pre-dialysis CKD patients. Random-effects meta-analysis was performed to obtain weighted mean annual eGFR decline. We included 60 studies (43 CKD 3-5 cohorts and 17 dialysis-based studies). The meta-analysis yielded a weighted annual mean (95% CI) eGFR decline during pre-dialysis of 2.4 (95% CI: 2.2, 2.6) mL/min/1.73 m 2 in CKD 3-5 cohorts compared to 8.5 (95% CI: 6.8, 10.1) in dialysis-based studies (difference 6.0 [95% CI: 4.8, 7.2]). To conclude, dialysis-based studies report faster mean annual eGFR decline during pre-dialysis than CKD 3-5 cohorts. Thus, eGFR decline data from CKD 3-5 cohorts should be used to guide clinical decision making in CKD patients and for power calculations in randomized controlled trials with CKD progression during pre-dialysis as the outcome.
Hepatocellular carcinoma in uremic patients: is there evidence for an increased risk of mortality?
Lee, Yun-Hsuan; Hsu, Chia-Yang; Hsia, Cheng-Yuan; Huang, Yi-Hsiang; Su, Chien-Wei; Lin, Han-Chieh; Lee, Rheun-Chuan; Chiou, Yi-You; Huo, Teh-Ia
2013-02-01
The clinical aspects of patients with hepatocellular carcinoma (HCC) undergoing maintenance dialysis are largely unknown. We aimed to investigate the long-term survival and prognostic determinants of dialysis patients with HCC. A total of 2502 HCC patients, including 30 dialysis patients and 90 age, sex, and treatment-matched controls were retrospectively analyzed. Dialysis patients more often had dual viral hepatitis B and C, lower serum α-fetoprotein level, worse performance status, higher model for end-stage liver disease (MELD) score than non-dialysis patients and matched controls (P all < 0.05). There was no significant difference in long-term survival between dialysis and non-dialysis patients and matched controls (P = 0.684 and 0.373, respectively). In the Cox proportional hazards model, duration of dialysis < 40 months (hazard ratio [HR]: 6.67, P = 0.019) and ascites (HR: 5.275, P = 0.019) were independent predictors of poor prognosis for dialysis patients with HCC. Survival analysis disclosed that the Child-Turcotte-Pugh (CTP) provided a better prognostic ability than the MELD system. Among the four currently used staging systems, the Japan Integrated Scoring (JIS) system was a more accurate prognostic model for dialysis patients; a JIS score ≥ 2 significantly predicted a worse survival (P = 0.024). Patients with HCC undergoing maintenance dialysis do not have a worse long-term survival. A longer duration of dialysis and absence of ascites formation are associated with a better outcome in dialysis patients. The CTP classification is a more feasible prognostic marker to indicate the severity of cirrhosis, and the JIS system may be a better staging model for outcome prediction. © 2012 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
[Blood clots in erythrocyte concentrates during transfusion].
Wagner, T; Drexler, C; Kröll, W; Jüngling, G; Lanzer, G; Gabriel, C
2008-12-01
The presence of multiple blood clots in leucocyte-depleted erythrocyte concentrates during a transfusion gave rise to an investigation to find the exact cause. Determination of the various blood group systems was carried out using the gel centrifugation method and also the polymerase chain reaction (PCR) using sequence-specific primers. In addition the human leucocyte antigens (HLA) class 1 and class 2 markers were determined with molecular biological methods. The erythrocytes in the blood bags containing the blood clots showed a mixed-field agglutination in each blood group where the donor and recipient had different phenotypes. The HLA groups, however, could be solely attributed to the patient, since during the preparation of erythrocyte concentrates all leucocytes are removed and only very few residual cells containing DNA are present. To the best of our knowledge, this is the first detailed report on blood clots from patient blood in erythrocyte concentrates, which occurred during a transfusion. The retrograde filling of the blood bag with patient blood during the transfusion led to coagulation in the bag. Therefore, careful attention must be taken when dealing with stored blood and corresponding training must be regularly carried out.
Névéol, Aurélie; Pereira, Suzanne; Kerdelhué, Gaetan; Dahamna, Badisse; Joubert, Michel; Darmoni, Stéfan J
2007-01-01
The growing number of resources to be indexed in the catalogue of online health resources in French (CISMeF) calls for curating strategies involving automatic indexing tools while maintaining the catalogue's high indexing quality standards. To develop a simple automatic tool that retrieves MeSH descriptors from documents titles. In parallel to research on advanced indexing methods, a bag-of-words tool was developed for timely inclusion in CISMeF's maintenance system. An evaluation was carried out on a corpus of 99 documents. The indexing sets retrieved by the automatic tool were compared to manual indexing based on the title and on the full text of resources. 58% of the major main headings were retrieved by the bag-of-words algorithm and the precision on main heading retrieval was 69%. Bag-of-words indexing has effectively been used on selected resources to be included in CISMeF since August 2006. Meanwhile, on going work aims at improving the current version of the tool.
Spirolit-2 instrument used to test pulmonary ventilation
NASA Astrophysics Data System (ADS)
Zhuravlev, V. V.
1985-02-01
At the present time, the Spirolit-2 automatic analyzer of main respiratory gases, of the Junkalor Dessau firm, is used to examine parameters of gas exchange, levels of energy expended by man and animals with different degrees of activity. However, the capabilities of this model of the instrument are limited. A method of determining pulmonary ventilation with use of the Spirolit-2 is described. An additional exhalation valve is built into a valve box to which an anesthesia machine rubber bag is attached. Samples are collected into another bag concurrently with the usual tests on the Spirolit-2 instrument. Four to five minutes are sufficient to obtain stable parameters at relative rest of oxygen uptake, determine carbon dioxide output per minute and collect samples in for analysis of exhaled air. The proposed method can furnish information about the dynamics of development of respiratory function of the lungs at virtually any moment with a constant physical load. For this, there must be spare bags to collect samples. Stage-by-stage data can be obtained analogously as to ventilation volume during a step test while determining maximum oxygen uptake.
NASA Astrophysics Data System (ADS)
Lozano-Vega, Gildardo; Benezeth, Yannick; Marzani, Franck; Boochs, Frank
2014-09-01
Accurate recognition of airborne pollen taxa is crucial for understanding and treating allergic diseases which affect an important proportion of the world population. Modern computer vision techniques enable the detection of discriminant characteristics. Apertures are among the important characteristics which have not been adequately explored until now. A flexible method of detection, localization, and counting of apertures of different pollen taxa with varying appearances is proposed. Aperture description is based on primitive images following the bag-of-words strategy. A confidence map is estimated based on the classification of sampled regions. The method is designed to be extended modularly to new aperture types employing the same algorithm by building individual classifiers. The method was evaluated on the top five allergenic pollen taxa in Germany, and its robustness to unseen particles was verified.
Investigating reduced bag weight as an effective risk mediator for mason tenders.
Davis, Kermit G; Kotowski, Susan E; Albers, James; Marras, William S
2010-10-01
Masonry workers face some of the highest physical demands in the construction industry where large bags of masonry material weighing 42.7 kg are commonly handled by mason tenders who mix the mortar, distribute mortar and bricks/blocks, and erect/dismantle scaffolding throughout the day. The objective of this study was to determine the effectiveness of using half-weight bags (21.4 kg) on reducing the biomechanical loading, physiological response, and perceived exertions. Ten male subjects performed asymmetric lifting tasks simulating unloading bags from a pallet. Muscle activity, trunk kinematics, heart rate, blood pressure and subjective rating data were collected. Spine loads were predicted from a well-validated EMG-assisted model. Bag weight, lift type, bag height at origin, and asymmetry at destination significantly impacted the spine loads. While there was a 50% reduction in bag weight, the peak loads for the half-weight bags were only 25% less than the more available full-weight bags (a reduction of about 320 N of shear and 1000 N of compression). Lifts allowing movement of the feet reduced the loads by about 22% in shear and 27% in compression compared to constrained postures. Interestingly, cumulative spine loads were greater for the lighter bags than the heavy bags ( approximately 40%). The subjective ratings of exertion and risk were significantly lower for the lighter bags. RELEVANCE TO INDUSTRY: The reduction in peak spine loading for the half-weight bags, particularly at the higher heights and when the feet were allowed to move could significantly reduce the injuries of masonry workers. However, there were trade-offs with cumulative loads that may minimize the reduced risk. Overall, given the limited amount of time lifting bags, the reduction of peak loads.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maier, Jana V., E-mail: Jana.maier@kit.edu; Volz, Yvonne; Berger, Caroline
2010-10-22
Research highlights: {yields}Bag-1 depletion only marginally affects the action of the glucocorticoid receptor but strongly regulates the activity of NF-{kappa}B. {yields}Bag-1 depletion attenuates phosphorylation and degradation of I{kappa}B{alpha} and nuclear accumulation of NF-{kappa}B p65 and p50. {yields}Bag-1 interacts with I{kappa}B{alpha} and partially restores I{kappa}B{alpha} and NF-{kappa}B activation in Bag-1 depleted cells. -- Abstract: Bag-1 consists in humans of four isoforms generated from the same RNA by alternative translation. Overexpression of single Bag-1 isoforms has identified Bag-1 as a negative regulator of action of many proteins including the glucocorticoid receptor (GR). Here we have analysed the ability of Bag-1 to regulatemore » the transrepression function of the GR. Silencing Bag-1 expression only marginally affects the transrepression action of the GR but decreased the action of the transcription factor NF-{kappa}B. Furthermore phosphorylation and degradation of the inhibitor protein I{kappa}B{alpha} and nuclear accumulation of p65 and p50 NF-{kappa}B proteins in response to phorbol ester was attenuated following Bag-1 depletion in HeLa cells. Reconstitution of Bag-1 in depleted cells partially restored I{kappa}B{alpha} and NF-{kappa}B activation. Knock-down of Bag-1 expression also did not significantly alter GR-mediated transactivation but affected the basal transcription of some of the target genes. Thus Bag-1 proteins function as regulators of the action of selective transcription factors.« less
Grabowska-Polanowska, Beata; Miarka, Przemysław; Skowron, Monika; Sułowicz, Joanna; Wojtyna, Katarzyna; Moskal, Karolina; Śliwka, Ireneusz
2017-10-01
The studies on volatile organic compounds emitted from skin are an interest for chemists, biologists and physicians due to their role in development of different scientific areas, including medical diagnostics, forensic medicine and the perfume design. This paper presents a proposal of two sampling methods applied to skin odor collection: the first one uses a bag of cellulose film, the second one, using cellulose sachets filled with active carbon. Volatile organic compounds were adsorbed on carbon sorbent, removed via thermal desorption and analyzed using gas chromatograph with mass spectrometer. The first sampling method allowed identification of more compounds (52) comparing to the second one (30). Quantitative analyses for acetone, butanal, pentanal and hexanal were done. The skin odor sampling method using a bag of cellulose film, allowed the identification of many more compounds when compared with the method using a sachet filled with active carbon.
Organ Donation Campaigns: Perspective of Dialysis Patient's Family Members
TUMIN, Makmor; RAJA ARIFFIN, Raja Noriza; MOHD SATAR, NurulHuda; NG, Kok-Peng; LIM, Soo-Kun; CHONG, Chin-Sieng
2014-01-01
Abstract Background Solving the dilemma of the organ shortage in Malaysia requires educating Malaysians about organ donation and transplantation. This paper aims at exploring the average Malaysian households ’ preferred channels of campaigns and the preferred campaigners in a family setting, targeting at the dialysis family members. Methods We analyzed the responses of 350 respondents regarding organ donation campaigns. The respondents are 2 family members of 175 dialysis patients from 3 different institutions. The information on respondents’ willingness to donate and preferred method and channel of organ donation campaign were collected through questionnaire. Results Malaysian families have a good tendency to welcome campaigns in both the public and private (their homes) spheres. We also found that campaigns facilitated by the electronic media (Television and Radio) and executed by experienced doctors are expected to optimize the outcomes of organ donation, in general. Chi-square tests show that there are no significant differences in welcoming campaigns among ethnics. However, ethnics preferences over the campaign methods and campaigners are significantly different (P <0.05). Conclusion Ethnic differences imply that necessary modifications on the campaign channels and campaigners should also be taken under consideration. By identifying the preferred channel and campaigners, this study hopes to shed some light on the ways to overcome the problem of organ shortage in Malaysia. PMID:25909060
Neal, Paul R; Anderson, Gregory J
2004-05-01
Fabrics used in pollination bags may exclude pollen carried by biotic vectors, but have varying degrees of permeability to wind-borne pollen. The permeability of bags to wind-borne pollen may have important consequences in studies of pollination and reproductive biology. The permeability of four fabrics commonly used in the construction of pollination bags was examined. Deposition of wind-borne pollen on horizontally and vertically oriented microscope slides was assessed on slides enclosed in pollination bags, as well as on control slides. It was found that the permeability of fabrics to wind-borne pollen, as measured by deposition on both horizontally and vertically oriented slides, decreased with pore size. However, deposition on horizontal slides was always greater than on vertical slides for a given fabric; this could manifest itself as differential success of pollination of flowers in bags-dependent on flower orientation. Obviously, bags with mesh size smaller than most pollen grains are impermeable to pollen. However, material for such bags is very expensive. In addition, it was also observed that bags with even moderately small pore size, such as pores (approx. 200 microm) in twisted fibre cotton muslin, offered highly significant barriers to passage of wind-borne pollen. Such bags are sufficiently effective in most large-sample-size reproductive biology studies.
Chiappetta, Gennaro; Basile, Anna; Arra, Claudio; Califano, Daniela; Pasquinelli, Rosa; Barbieri, Antonio; De Simone, Veronica; Rea, Domenica; Giudice, Aldo; Pezzullo, Luciano; De Laurenzi, Vincenzo; Botti, Gerardo; Losito, Simona; Conforti, Daniela; Turco, Maria Caterina
2012-01-01
Anaplastic thyroid tumors (ATC) express high levels of BAG3, a member of the BAG family of cochaperone proteins that is involved in regulating cell apoptosis through multiple mechanisms. The objective of the study was the investigation of the influence of B-cell lymphoma-2-associated athanogene 3 (BAG3) on ATC growth. We investigated the effects of BAG3 down-modulation, obtained by using a specific small interfering RNA, on in vitro and in vivo growth of the human ATC cell line 8505C. Because BRAF protein plays an important role in ATC cell growth, we analyzed the effects of BAG3 down-modulation on BRAF protein levels. Furthermore, by using a proteasome inhibitor, we verified whether BAG3-mediated regulation of BRAF levels involved a proteasome-dependent mechanism. BAG3 down-modulation significantly inhibits ATC growth in vitro and in vivo. BAG3 coimmunoprecipitates with BRAF protein, and its down-modulation results in a significant reduction of BRAF protein levels, which can be reverted by incubation with the proteasome inhibitor MG132. BAG3 protein sustains ATC growth in vitro and in vivo. The underlying molecular mechanism appears to rely on BAG3 binding to BRAF, thus protecting it from proteasome-dependent degradation. These results are in line with the reported ability of BAG3 to interfere with the proteasomal delivery of a number of other client proteins.
Chiappetta, Gennaro; Basile, Anna; Barbieri, Antonio; Falco, Antonia; Rosati, Alessandra; Festa, Michelina; Pasquinelli, Rosa; Califano, Daniela; Palma, Giuseppe; Costanzo, Raffaele; Barcaroli, Daniela; Capunzo, Mario; Franco, Renato; Rocco, Gaetano; Pascale, Maria; Turco, Maria Caterina; De Laurenzi, Vincenzo; Arra, Claudio
2014-08-30
BAG3, member the HSP70 co-chaperones family, has been shown to play a relevant role in the survival, growth and invasiveness of different tumor types. In this study, we investigate the expression of BAG3 in 66 specimens from different lung tumors and the role of this protein in small cell lung cancer (SCLC) tumor growth. Normal lung tissue did not express BAG3 while we detected the expression of BAG3 by immunohistochemistry in all the 13 squamous cell carcinomas, 13 adenocarcinomas and 4 large cell carcinomas. Furthermore, we detected BAG3 expression in 22 of the 36 SCLCs analyzed. The role on SCLC cell survival was determined by down-regulating BAG3 levels in two human SCLC cell lines, i.e. H69 and H446, in vitro and measuring cisplatin induced apoptosis. Indeed down-regulation of BAG3 determines increased cell death and sensitizes cells to cisplatin treatment. The effect of BAG3 down-regulation on tumor growth was also investigated in an in vivo xenograft model by treating mice with an adenovirus expressing a specific bag3 siRNA. Treatment with bag3 siRNA-Ad significantly reduced tumor growth and improved animal survival. In conclusion we show that a subset of SCLCs over express BAG3 that exerts an anti-apoptotic effect resulting in resistance to chemotherapy.
Michelot, Harmonie; Fu, Shanlin; Stuart, Barbara; Shimmon, Ronald; Raymond, Tony; Crandell, Tony; Roux, Claude
2017-04-01
In the area of clandestine laboratory investigations, plastic bags are used to collect and store evidence, such as solvents, precursors, and other compounds usually employed for the manufacturing of drugs (although liquids may be stored in glass containers within the bags first). In this study, three different types of plastic bags were provided by the NSW Police Force and investigated for their suitability for evidence collection: two different types of low-density polyethylene (LDPE) bags and one type of polyvinyl chloride (PVC) bag. Three different experiments were carried out: (1) storing relevant chemicals in the bags for up to three months; (2) exposing the bags including their content to accelerated conditions using a weatherometer, and (3) simulating an expected real case scenario. This study indicates that drugs and related chemicals stored in plastic bags may lead to a change in the composition of the chemical and an alteration or degradation of the plastic bag. All experiments led to the same conclusion: the polyvinyl chloride bags appeared to be the most affected. LDPE bags seem to be more appropriate for routine use, although it has been established they are not suitable for the collection of liquids (unless pre-packaged in, for instance, a glass container). Copyright © 2017 Elsevier B.V. All rights reserved.
Piccoli, Giorgina Barbara; Sofronie, Andreea Corina; Coindre, Jean-Philippe
2017-11-09
Starting dialysis at an advanced age is a clinical challenge and an ethical dilemma. The advantages of starting dialysis at "extreme" ages are questionable as high dialysis-related morbidity induces a reflection on the cost- benefit ratio of this demanding and expensive treatment in a person that has a short life expectancy. Where clinical advantages are doubtful, ethical analysis can help us reach decisions and find adapted solutions. Mr. H is a ninety-year-old patient with end-stage kidney disease that is no longer manageable with conservative care, in spite of optimal nutritional management, good blood pressure control and strict clinical and metabolic evaluations; dialysis is the next step, but its morbidity is challenging. The case is analysed according to principlism (beneficence, non-maleficence, justice and respect for autonomy). In the setting of care, dialysis is available without restriction; therefore the principle of justice only partially applied, in the absence of restraints on health-care expenditure. The final decision on whether or not to start dialysis rested with Mr. H (respect for autonomy). However, his choice depended on the balance between beneficence and non-maleficence. The advantages of dialysis in restoring metabolic equilibrium were clear, and the expected negative effects of dialysis were therefore decisive. Mr. H has a contraindication to peritoneal dialysis (severe arthritis impairing self-performance) and felt performing it with nursing help would be intrusive. Post dialysis fatigue, poor tolerance, hypotension and intrusiveness in daily life of haemodialysis patients are closely linked to the classic thrice-weekly, four-hour schedule. A personalized incremental dialysis approach, starting with one session per week, adapting the timing to the patient's daily life, can limit side effects and "dialysis shock". An individualized approach to complex decisions such as dialysis start can alter the delicate benefit/side-effect balance, ultimately affecting the patient's choice, and points to a narrative, tailor-made approach as an alternative to therapeutic nihilism, in very old and fragile patients.
Tzur, Shay; Rosset, Saharon; Skorecki, Karl; Wasser, Walter G
2012-04-01
The APOL1 G1 and G2 genetic variants make a major contribution to the African ancestry risk for a number of common forms of non-diabetic end-stage kidney disease (ESKD). We sought to clarify the relationship of APOL1 variants with age of dialysis initiation and dialysis vintage (defined by the time between dialysis initiation and sample collection) in African and Hispanic Americans, diabetic and non-diabetic ESKD. We examined APOL1 genotypes in 995 African and Hispanic American dialysis patients with diabetic and non-diabetic ESKD. The mean age of dialysis initiation for non-diabetic African-American patients with two APOL1 risk alleles was 48.1 years, >9 years earlier than those without APOL1 risk alleles (t-test, P=0.0003). Similar results were found in the non-diabetic Hispanic American cohort, but not in the diabetic cohorts. G1 heterozygotes showed a 5.3-year lower mean age of dialysis initiation (t-test, P=0.0452), but G2 heterozygotes did not show such an effect. At the age of 70, 92% of individuals with two APOL1 risk alleles had already initiated dialysis, compared with 76% of the patients without APOL1 risk alleles. Although two APOL1 risk alleles are also associated with ∼2 years increased in dialysis vintage, further analysis showed that this increase is fully explained by earlier age of dialysis initiation. Two APOL1 risk alleles significantly predict lower age of dialysis initiation and thereby increased dialysis vintage in non-diabetic ESKD African and Hispanic Americans, but not in diabetic ESKD. A single APOL1 G1, but not G2, risk allele also lowers the age of dialysis initiation, apparently consistent with gain of injury or loss of function mechanisms. Hence, APOL1 mutations produce a distinct category of kidney disease that manifests at younger ages in African ancestry populations.
... this page: //medlineplus.gov/ency/patientinstructions/000142.htm Urine drainage bags To use the sharing features on this page, please enable JavaScript. Urine drainage bags collect urine. Your bag will attach ...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-16
... Bags From Thailand: Correction to the Amended Final Results of Antidumping Duty Administrative Review... bags from Thailand for the period August 1, 2009, through July 31, 2010. The notice did not include the... bags from Thailand. See Polyethylene Retail Carrier Bags From Thailand: Amended Final Results of...
49 CFR 178.519 - Standards for plastic film bags.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Standards for plastic film bags. 178.519 Section...-bulk Performance-Oriented Packaging Standards § 178.519 Standards for plastic film bags. (a) The identification code for a plastic film bag is 5H4. (b) Construction requirements for plastic film bags are as...