The truth about laser fiber diameters.
Kronenberg, Peter; Traxer, Olivier
2014-12-01
To measure the various diameters of laser fibers from various manufacturers and compare them with the advertised diameter. Fourteen different unused laser fibers from 6 leading manufacturers with advertised diameters of 200, 270, 272, 273, 365, and 400 μm were measured by light microscopy. The outer diameter (including the fiber coating, cladding, and core), cladding diameter (including the cladding and the fiber core), and core diameter were measured. Industry representatives of the manufacturers were interviewed about the diameter of their fibers. For all fibers, the outer and cladding diameters differed significantly from the advertised diameter (P <.00001). The outer diameter, which is of most practical relevance for urologists, exhibited a median increase of 87.3% (range, 50.7%-116.7%). The outer, cladding, and core diameters of fibers with equivalent advertised diameters differed by up to 180, 100, and 78 μm, respectively. Some 200-μm fibers had larger outer diameters than the 270- to 273-μm fibers. All packaging material and all laser fibers lacked clear and precise fiber diameter information labels. Of 12 representatives interviewed, 8, 3, and 1 considered the advertised diameter to be the outer, the cladding, and the core diameter, respectively. Representatives within the same company frequently gave different answers. This study suggests that, at present, there is a lack of uniformity between laser fiber manufacturers, and most of the information conveyed to urologists regarding laser fiber diameter may be incorrect. Because fibers larger than the advertised laser fibers are known to influence key interventional parameters, this misinformation can have surgical repercussions. Copyright © 2014 Elsevier Inc. All rights reserved.
Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.
Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek
2003-05-01
Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.
Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand
Laura S. Kenefic; R.D. Nyland
1999-01-01
Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...
Estimating past diameters of Douglas-fir trees.
Floyd A. Johnson
1955-01-01
Estimates of breast-height diameter outside bark for trees as of some previous date are required in certain kinds of forest growth studies. These past diameters may be found by subtracting total diameter growth from known present diameters, where total diameter growth is the sum of wood growth and bark growth. Wood growth is readily obtained by...
33 CFR Appendix A to Part 155 - Specifications for Shore Connection
Code of Federal Regulations, 2013 CFR
2013-07-01
... of this part] Item Description Dimension 1 Outside diameter 215 mm. (8 in.). 2 Inside diameter According to pipe outside diameter. 3 Bolt circle diameter 183 mm. (7 3/16 in.). 4 Slots in flange 6 holes 22 mm. (7/8 in.) in diameter shall be equidistantly placed on a bolt circle of the above diameter...
33 CFR Appendix A to Part 155 - Specifications for Shore Connection
Code of Federal Regulations, 2011 CFR
2011-07-01
... of this part] Item Description Dimension 1 Outside diameter 215 mm. (8 in.). 2 Inside diameter According to pipe outside diameter. 3 Bolt circle diameter 183 mm. (7 3/16 in.). 4 Slots in flange 6 holes 22 mm. (7/8 in.) in diameter shall be equidistantly placed on a bolt circle of the above diameter...
33 CFR Appendix A to Part 155 - Specifications for Shore Connection
Code of Federal Regulations, 2014 CFR
2014-07-01
... of this part] Item Description Dimension 1 Outside diameter 215 mm. (8 in.). 2 Inside diameter According to pipe outside diameter. 3 Bolt circle diameter 183 mm. (7 3/16 in.). 4 Slots in flange 6 holes 22 mm. (7/8 in.) in diameter shall be equidistantly placed on a bolt circle of the above diameter...
33 CFR Appendix A to Part 155 - Specifications for Shore Connection
Code of Federal Regulations, 2012 CFR
2012-07-01
... of this part] Item Description Dimension 1 Outside diameter 215 mm. (8 in.). 2 Inside diameter According to pipe outside diameter. 3 Bolt circle diameter 183 mm. (7 3/16 in.). 4 Slots in flange 6 holes 22 mm. (7/8 in.) in diameter shall be equidistantly placed on a bolt circle of the above diameter...
Estimating past diameters of mixed conifer species in the central Sierra Nevada
K. Leroy Dolph
1981-01-01
Tree diameter outside bark at an earlier period of growth can be estimated from the linear relationship of present inside bark and outside bark diameters at breast height. This note presents equations for estimating inside bark diameters, outside bark diameters, and past outside bark diameters for each of the mixed-conifer species in the central Sierra Nevada.
Wu, Qian; Pagès, Loïc; Wu, Jie
2016-01-01
Background and Aims Root diameter, especially apical diameter, plays an important role in root development and function. The variation in diameter between roots, and along roots, affects root structure and thus the root system’s overall foraging performance. However, the effect of diameter variation on root elongation, branching and topological connections has not been examined systematically in a population of high-order roots, nor along the roots, especially for mature plants grown in the field. Methods A method combining both excavation and analysis was applied to extract and quantify root architectural traits of adult, field-grown maize plants. The relationships between root diameter and other root architectural characteristics are analysed for two maize cultivars. Key Results The basal diameter of the lateral roots (orders 1–3) was highly variable. Basal diameter was partly determined by the diameter of the bearing segment. Basal diameter defined a potential root length, but the lengths of most roots fell far short of this. This was explained partly by differences in the pattern of diameter change along roots. Diameter tended to decrease along most roots, with the steepness of the gradient of decrease depending on basal diameter. The longest roots were those that maintained (or sometimes increased) their diameters during elongation. The branching density (cm–1) of laterals was also determined by the diameter of the bearing segment. However, the location of this bearing segment along the mother root was also involved – intermediate positions were associated with higher densities of laterals. Conclusions The method used here allows us to obtain very detailed records of the geometry and topology of a complex root system. Basal diameter and the pattern of diameter change along a root were associated with its final length. These relationships are especially useful in simulations of root elongation and branching in source–sink models. PMID:26744490
Ihara, Tsutomu; Komori, Kimihiro; Yamamoto, Kiyohito; Kobayashi, Masayoshi; Banno, Hiroshi; Kodama, Akio
2013-02-01
Abdominal aortic aneurysm diameter is usually measured by the maximum minor-axis diameter on axial computed tomography (CT). However, this "traditional" diameter may underestimate the real size, as the aorta is not always straight and the aneurysm shape is sometimes in the form of an ellipse along the cross section. Therefore, we measured maximum major-axis diameters using a three-dimensional (3D) workstation and compared them with the traditional maximum minor-axis diameters measured using thin-slice axial CT. CT data of 141 AAA patients (with fusiform aneurysms) were stored in a 3D workstation. These thin-slice CT images were reviewed on the 3D workstation to obtain curved multiplanar reconstruction images (CPR images). Using the CPR images, we measured the maximum major-axis and minor-axis diameters on CPR and the angle of the aneurysms to the body axis. The mean traditional maximum minor-axis diameter was 51.2 ± 8.2 mm, whereas the mean maximum major-axis diameter on CPR was 54.7 ± 10.1 mm. Sixty eight patients had a mean aneurysm size of <50 mm when measured by the traditional minor-axis diameter. Among these patients, five (7.4%) had a major-axis diameter >55 mm on CPR. The measurement of the traditional maximum minor-axis diameter of aneurysms is useful in the case of most patients. However, the traditional maximum minor-axis diameter may underestimate the real aneurysmal diameter, particularly in patients with an ellipse-shaped aneurysm. The maximum major-axis diameter as measured using CPR images is effective for representing the real aneurysmal size. Copyright © 2013 Elsevier Inc. All rights reserved.
Wiebe, David J.; Charron, Richard C.; Morrison, Jay A.
2016-10-18
A gas turbine engine ducting arrangement (10), including: an annular chamber (14) configured to receive a plurality of discrete flows of combustion gases originating in respective can combustors and to deliver the discrete flows to a turbine inlet annulus, wherein the annular chamber includes an inner diameter (52) and an outer diameter (60); an outer diameter mounting arrangement (34) configured to permit relative radial movement and to prevent relative axial and circumferential movement between the outer diameter and a turbine vane carrier (20); and an inner diameter mounting arrangement (36) including a bracket (64) secured to the turbine vane carrier, wherein the bracket is configured to permit the inner diameter to move radially with the outer diameter and prevent axial deflection of the inner diameter with respect to the outer diameter.
K. Leroy Dolph
1984-01-01
The linear relationship of inside to outside bark diameter at breast height provides a basis for estimating diameter inside bark from diameter outside bark. Estimates of diameter inside bark and past diameter outside bark are useful in predicting growth and yield. During field seasons 1979-1982, data were obtained from stem analysis of 931 trees in young-growth stands...
Variation and Heritability in Hair Diameter and Curvature in an Australian Twin Sample.
Ho, Yvonne Y W; Brims, Mark; McNevin, Dennis; Spector, Timothy D; Martin, Nicholas G; Medland, Sarah E
2016-08-01
Hair diameter and curvature are two characteristics of human scalp hair used in forensic contexts. While previous data show that subjective categorization of hair curvature is highly heritable, the heritability of objectively measured curvature and diameter, and variability of hair characteristics within each individual have not yet been studied. The present study measured hair diameter and curvature using an optical fiber diameter analyzer in a sample of 2,332 twins and siblings. Heritability was estimated using maximum likelihood structural equation modeling. Results show sex differences in the magnitude of genetic influence for mean diameter and curvature, with the vast majority of the variance accounted for by genetic effects in males (diameter = 86%, curvature = 53%) and females (diameter = 77%, curvature = 61%). The consistency of diameter (variance within an individual) was also highly heritable, but did not show sex limitation, with 68% of the variance accounted for by genetic factors. Moderate phenotypic correlations were seen between diameter and consistency (r = 0.3) but there was little correlation between diameter and curvature (r = -0.13). A bivariate Cholesky analysis was used to estimate the genetic and environmental correlations between hair diameter and consistency, yielding genetic correlations of r gF = 0.27 for females and r gM = 0.25 for males.
Variation of the pressure limits of flame propagation with tube diameter for propane-air mixtures
NASA Technical Reports Server (NTRS)
Belles, Frank E; Simon, Dorothy M
1951-01-01
An investigation was made of the variation of the pressure limits of flame propagation with tube diameter for quiescent propane with tube diameter for quiescent propane-air mixtures. Pressure limits were measured in glass tubes of six different inside diameters, with a precise apparatus. Critical diameters for flame propagation were calculated and the effect of pressure was determined. The critical diameters depended on the pressure to the -0.97 power for stoichiometric mixtures. The pressure dependence decreased with decreasing propane concentration. Critical diameters were related to quenching distance, flame speeds, and minimum ignition energy.
Fiber diameter distributions in the chinchilla's ampullary nerves
NASA Technical Reports Server (NTRS)
Hoffman, Larry F.; Honrubia, Vicente
2002-01-01
A morphometric study of the chinchilla's ampullary nerves was conducted to produce an unbiased accounting of the diameter distribution of their constituent fibers. Diameter analyses were determined from 1 microm plastic-embedded nerve sections taken at a plane immediately proximal to the sensory epithelium. We found these nerves to be composed of 2094+/-573 fibers, having diameters that ranged from 0.5 to 8 microm. The distributions of diameters were positively skewed, where approximately 75% of the fibers were found to have diameters less than 3.5 microm. An analysis of the spatial distribution of diameters within the nerve section revealed that the lateralmost areas of the nerve contained larger fractions of fibers within the smallest diameter quintiles, and the central area harbored greater proportions of the larger diameter quintiles. However, significant fractions of all quintiles were found in all areas. These data were integrated with available data of Fernandez et al. (1998) to produce diameter estimates of calyx, dimorphic, and bouton morphology subpopulations. In view of a general relationship between diameter, innervation locus, and an afferent's physiologic characteristics, these data provide the basis for developing a perspective for the in situ distribution of afferent response dynamics.
Comparison of diameters at the cementoenamel junction between South Asians and Japanese.
Nose, Hirohisa; Tawada, Yasuyuki; Watanabe, Fumihiko; Kageyama, Ikuo
2011-01-01
Previously, sex differences among the various tooth types in Japanese skulls were examined to facilitate choosing an implant diameter similar to the cervical diameter of each tooth, and it was found that mesiodistal diameters at the cementoenamel junction were narrower in women than in men. Also interesting and relevant to the selection of implant diameter is the possible existence of racial differences in diameters at the cementoenamel junction. The purpose of this research was to test the hypothesis that the diameter at the cementoenamel junction of the tooth differs in humans of different races. We compared 106 skulls of unknown sex collected from South Asia with the skulls of Japanese women. Our conclusions are as follows: (1) Except for the lower canine, no significant racial differences were found in the labiolingual diameter of any teeth. (2) Except for the upper canine, upper central incisor, lower second premolar, and lower first premolar, a significant racial difference was found in the mesiodistal diameter. In all teeth in which this value differed, the mesiodistal diameters of South Asians were narrower than those of Japanese women, except for the lower canine. (3) The labiolingual and mesiodistal diameters of the lower canine were significantly larger in South Asians than in Japanese women. (4) Among South Asians, no significant left/right differences were found in the diameter at the cementoenamel junction of any tooth.
Floyd. Johnson
1966-01-01
Recent emphasis on the measurement of upper stem tree diameters with optical dendrometers has directed attention to procedures for converting these outside-bark diameters to inside-bark diameters. One procedure that has been used requires an assumption that the ratio of diameter inside bark to diameter outside bark (henceforth called bark factor) remains the same up...
Origin of sigmoid diameter distributions
William B. Leak
2002-01-01
Diameter distributions--numbers of trees over diameter at breast height (d.b.h.)--were simulated over 20-years using six diameter-growth schedules, six mortality trends, and three initial conditions. The purpose was to determine factors responsible for the short-term development of the arithmetic rotated sigmoid form of diameter distribution characterized by a plateau...
Remky, A; Arend, O; Beausencourt, E; Elsner, A E; Bertram, B
1996-01-01
Retinal vessel diameter is an important parameter in blood flow analysis. Despite modern digital image technology, most clinical studies investigate diameters subjectively using projected fundus slides or negatives. In the present study we used a technique to examine vessel diameters by digital image analysis of color fundus slides. We investigated in a retrospective manner diameter changes in twenty diabetic patients before and after panretinal laser coagulation. Color fundus slides were digitized by a new high resolution scanning device. The resulting images consisted in three channels (red, green, blue). Since vessel contrast was the highest in the green channel, we assessed grey value profiles perpendicular to the vessels in the green channel. Diameters were measured at the half-height of the profile. After panretinal laser coagulation, average venous diameter was decreased, whereas arterial diameter remained unchanged. There was no significant relation between the diameter change and the number of laser burns or the presence of neovascularization. Splitting digitized images into color planes enables objective measurements of retinal diameters in conventional color slides.
Diameter Control and Photoluminescence of ZnO Nanorods from Trialkylamines
Andelman, Tamar; Gong, Yinyan; Neumark, Gertrude; ...
2007-01-01
A novel solution method to control the diameter of ZnO nanorods is reported. Small diameter (2-3 nm) nanorods were synthesized from trihexylamine, and large diameter (50–80 nm) nanorods were synthesized by increasing the alkyl chain length to tridodecylamine. The defect (green) emission of the photoluminescence (PL) spectra of the nanorods varies with diameter, and can thus be controlled by the diameter control. The small ZnO nanorods have strong green emission, while the large diameter nanorods exhibit a remarkably suppressed green band. We show that this observation supports surface oxygen vacancies as the defect that gives rise to the green emission.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a line running from the stem to the blossom...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a line running from the stem to the blossom...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a line running from the stem to the blossom...
Quantification of pulmonary vessel diameter in low-dose CT images
NASA Astrophysics Data System (ADS)
Rudyanto, Rina D.; Ortiz de Solórzano, Carlos; Muñoz-Barrutia, Arrate
2015-03-01
Accurate quantification of vessel diameter in low-dose Computer Tomography (CT) images is important to study pulmonary diseases, in particular for the diagnosis of vascular diseases and the characterization of morphological vascular remodeling in Chronic Obstructive Pulmonary Disease (COPD). In this study, we objectively compare several vessel diameter estimation methods using a physical phantom. Five solid tubes of differing diameters (from 0.898 to 3.980 mm) were embedded in foam, simulating vessels in the lungs. To measure the diameters, we first extracted the vessels using either of two approaches: vessel enhancement using multi-scale Hessian matrix computation, or explicitly segmenting them using intensity threshold. We implemented six methods to quantify the diameter: three estimating diameter as a function of scale used to calculate the Hessian matrix; two calculating equivalent diameter from the crosssection area obtained by thresholding the intensity and vesselness response, respectively; and finally, estimating the diameter of the object using the Full Width Half Maximum (FWHM). We find that the accuracy of frequently used methods estimating vessel diameter from the multi-scale vesselness filter depends on the range and the number of scales used. Moreover, these methods still yield a significant error margin on the challenging estimation of the smallest diameter (on the order or below the size of the CT point spread function). Obviously, the performance of the thresholding-based methods depends on the value of the threshold. Finally, we observe that a simple adaptive thresholding approach can achieve a robust and accurate estimation of the smallest vessels diameter.
NASA Astrophysics Data System (ADS)
Lothet, Emilie H.; Shaw, Kendrick M.; Horn, Charles C.; Lu, Hui; Wang, Yves T.; Jansen, E. Duco; Chiel, Hillel J.; Jenkins, Michael W.
2016-03-01
Sensory information is conveyed to the central nervous system via small diameter unmyelinated fibers. In general, smaller diameter axons have slower conduction velocities. Selective control of such fibers could create new clinical treatments for chronic pain, nausea in response to chemo-therapeutic agents, or hypertension. Electrical stimulation can control axonal activity, but induced axonal current is proportional to cross-sectional area, so that large diameter fibers are affected first. Physiologically, however, synaptic inputs generally affect small diameter fibers before large diameter fibers (the size principle). A more physiological modality that first affected small diameter fibers could have fewer side effects (e.g., not recruiting motor axons). A novel mathematical analysis of the cable equation demonstrates that the minimum length along the axon for inducing block scales with the square root of axon diameter. This implies that the minimum length along an axon for inhibition will scale as the square root of axon diameter, so that lower radiant exposures of infrared light will selectively affect small diameter, slower conducting fibers before those of large diameter. This prediction was tested in identified neurons from the marine mollusk Aplysia californica. Radiant exposure to block a neuron with a slower conduction velocity (B43) was consistently lower than that needed to block a faster conduction velocity neuron (B3). Furthermore, in the vagus nerve of the musk shrew, lower radiant exposure blocked slow conducting fibers before blocking faster conducting fibers. Infrared light can selectively control smaller diameter fibers, suggesting many novel clinical treatments.
Retransformation bias in a stem profile model
Raymond L. Czaplewski; David Bruce
1990-01-01
An unbiased profile model, fit to diameter divided by diameter at breast height, overestimated volume of 5.3-m log sections by 0.5 to 3.5%. Another unbiased profile model, fit to squared diameter divided by squared diameter at breast height, underestimated bole diameters by 0.2 to 2.1%. These biases are caused by retransformation of the predicted dependent variable;...
Controlling diameter distribution of catalyst nanoparticles in arc discharge.
Li, Jian; Volotskova, Olga; Shashurin, Alexey; Keidar, Michael
2011-11-01
It is demonstrated that the diameter distribution of catalyst nanoparticles in arc discharge can be controlled by a magnetic field. The magnetic field affects the arc shape, shortens the diffusing time of the catalyst nanoparticles through the nucleation zone, and consequentially reduces the average diameters of nanoparticles. The average diameter is reduced from about 7.5 nm without magnetic field to about 5 nm is the case of a magnetic field. Decrease of the catalyst nanoparticle diameter with magnetic field correlates well with decrease in the single-wall carbon nanotube and their bundles diameters.
Displacer Diameter Effect in Displacer Pulse Tube Refrigerator
NASA Astrophysics Data System (ADS)
Zhu, Shaowei
2017-12-01
Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.
Hunnam, J C; Parkinson, T J; Lopez-Villalobos, N; McDougall, S
2009-09-01
To determine bovine fetal characteristics significantly associated with increasing gestational age as measured via transcutaneous ultrasonography over the right flank. The length of gestation at date of pregnancy diagnosis via transcutaneous and transrectal ultrasonography was determined for 224 dairy cattle by estimation from subsequent calving dates. A separate dataset was created for each measurable fetal characteristic (i.e. thoracic diameter, abdominal diameter, umbilical diameter, placentome length and placentome height) and risk factors significantly associated with gestational age at pregnancy diagnosis within each dataset, including the fetal characteristic, were identified. Abdominal diameter was the most frequently observed fetal characteristic and thoracic diameter was the least. Gestational age at pregnancy diagnosis (d) was significantly associated with fetal thoracic diameter (P < 0.01), abdominal diameter (P < 0.01) and umbilical diameter (P = 0.02) when measured via transcutaneous ultrasound. Within each model, sire breed, dam breed, dam age and/or calf sex were also significantly associated with gestational age. Gestational age at pregnancy diagnosis was not significantly associated with either placentome height or length (P > 0.05). Fetal thoracic diameter, abdominal diameter and umbilical diameter were found to be significantly associated with gestational age between approximate days 73 to 190 of gestation. Transcutaneous ultrasonography may prove a useful method of estimating gestational age in the absence of accurate breeding records.
Predicting Diameter at Breast Height from Stump Diameters for Northeastern Tree Species
Eric H. Wharton; Eric H. Wharton
1984-01-01
Presents equations to predict diameter at breast height from stump diameter measurements for 17 northeastern tree species. Simple linear regression was used to develop the equations. Application of the equations is discussed.
NASA Astrophysics Data System (ADS)
Thendie, Boanerges; Omachi, Haruka; Hirotani, Jun; Ohno, Yutaka; Miyata, Yasumitsu; Shinohara, Hisanori
2017-06-01
Large-diameter semiconductor single-wall carbon nanotubes (s-SWCNTs) have superior mobility and conductivity to small-diameter s-SWCNTs. However, the purification of s-SWCNTs with diameters larger than 1.6 nm by gel filtration has been difficult owing to the low selectivity of the conventional purification method in these large-diameter regions. We report a combination of temperature-controlled gel filtration and the gradient elution technique that we developed to enrich a high-purity s-SWCNT with a diameter as large as 1.9 nm. The thin-film transistor (TFT) device using the 1.9-nm-diameter SWCNT shows an average channel mobility of 23.7 cm2 V-1 s-1, which is much higher than those of conventional SWCNT-TFTs with smaller-diameters of 1.5 and 1.4 nm.
High pressure fiber optic sensor system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guida, Renato; Xia, Hua; Lee, Boon K
2013-11-26
The present application provides a fiber optic sensor system. The fiber optic sensor system may include a small diameter bellows, a large diameter bellows, and a fiber optic pressure sensor attached to the small diameter bellows. Contraction of the large diameter bellows under an applied pressure may cause the small diameter bellows to expand such that the fiber optic pressure sensor may measure the applied pressure.
Randall B. Heiligmann; Jeffery S. Ward
1993-01-01
The effects of diameter-limit cutting on the future species composition and development of 60-80 year-old upland oak stands were studied in southern Ohio. Four treatments, 11-inch diameter-limit cut, 14-inch diameter-limit cut with selective thinning, 14-inch diameter-limit cut with low thinning, and uncut control were evaluated on medium oak sites (black oak site...
Crown-Diameter Prediction Models for 87 Species of Stand-Grown Trees in the Eastern United States
William A. Bechtold
2003-01-01
The mean crown diameters of stand-grown trees were modeled as a function of stem diameter, live-crown ratio, stand basal area, latitude, longitude, elevation, and Hopkins bioclimatic index for 87 tree species in the eastern United States. Stem diameter was statistically significant in all models, and a quadratic term for stem diameter was required for some species....
Giorgio Vacchiano; John D. Shaw; R. Justin DeRose; James N. Long
2008-01-01
Diameter increment is an important variable in modeling tree growth. Most facets of predicted tree development are dependent in part on diameter or diameter increment, the most commonly measured stand variable. The behavior of the Forest Vegetation Simulator (FVS) largely relies on the performance of the diameter increment model and the subsequent use of predicted dbh...
Twentieth-century decline of large-diameter trees in Yosemite National Park, California, USA
Lutz, J.A.; van Wagtendonk, J.W.; Franklin, J.F.
2009-01-01
Studies of forest change in western North America often focus on increased densities of small-diameter trees rather than on changes in the large tree component. Large trees generally have lower rates of mortality than small trees and are more resilient to climate change, but these assumptions have rarely been examined in long-term studies. We combined data from 655 historical (1932-1936) and 210 modern (1988-1999) vegetation plots to examine changes in density of large-diameter trees in Yosemite National Park (3027 km2). We tested the assumption of stability for large-diameter trees, as both individual species and communities of large-diameter trees. Between the 1930s and 1990s, large-diameter tree density in Yosemite declined 24%. Although the decrease was apparent in all forest types, declines were greatest in subalpine and upper montane forests (57.0% of park area), and least in lower montane forests (15.3% of park area). Large-diameter tree densities of 11 species declined while only 3 species increased. Four general patterns emerged: (1) Pinus albicaulis, Quercus chrysolepis, and Quercus kelloggii had increases in density of large-diameter trees occur throughout their ranges; (2) Pinus jeffreyi, Pinus lambertiana, and Pinus ponderosa, had disproportionately larger decreases in large-diameter tree densities in lower-elevation portions of their ranges; (3) Abies concolor and Pinus contorta, had approximately uniform decreases in large-diameter trees throughout their elevational ranges; and (4) Abies magnifica, Calocedrus decurrens, Juniperus occidentalis, Pinus monticola, Pseudotsuga menziesii, and Tsuga mertensiana displayed little or no change in large-diameter tree densities. In Pinus ponderosa-Calocedrus decurrens forests, modern large-diameter tree densities were equivalent whether or not plots had burned since 1936. However, in unburned plots, the large-diameter trees were predominantly A. concolor, C. decurrens, and Q. chrysolepis, whereas P. ponderosa dominated the large-diameter component of burned plots. Densities of large-diameter P. ponderosa were 8.1 trees ha-1 in plots that had experienced fire, but only 0.5 trees ha-1 in plots that remained unburned. ?? 2009 Elsevier B.V. All rights reserved.
K. Leroy Dolph
1989-01-01
Inside bark diameters of young-growth red fir can be estimated from the relationship of inside bark diameter 10 outside bark diameter at breast height. Inside and outside bark diameter were obtained from stem analyses of 562 trees distributed across 56 sampling locations in the true fir forest type of California and southern Oregon. The resulting equation can predict...
Mariella, Jr., Raymond P.
2018-03-06
An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.
Jiang, Guobin; Liu, Dan; Chen, Weiming; Ye, Zhicheng; Liu, Hong; Li, Qibin
2017-10-01
The evolution mechanism of a vent pipe diameter on a waste-stabilization process in semi-aerobic bioreactor landfills was analyzed from the organic-matter concentration, biodegradability, spectral characteristics of dissolved organic matter, correlations and principal-component analysis. Waste samples were collected at different distances from the vent pipe and from different landfill layers in semi-aerobic bioreactor landfills with different vent pipe diameters. An increase in vent pipe diameter favored waste degradation. Waste degradation in landfills can be promoted slightly when the vent pipe diameter increases from 25 to 50 mm. It could be promoted significantly when the vent pipe diameter was increased to 75 mm. The vent pipe diameter is important in waste degradation in the middle layer of landfills. The dissolved organic matter in the waste is composed mainly of long-wave humus (humin), short-wave humus (fulvic acid) and tryptophan. The humification levels of the waste that was located at the center of vent pipes with 25-, 50- and 75-mm diameters were 2.2682, 4.0520 and 7.6419 Raman units, respectively. The appropriate vent pipe diameter for semi-aerobic bioreactor landfills with an 800-mm diameter was 75 mm. The effect of different vent pipe diameters on the degree of waste stabilization is reflected by two main components. Component 1 is related mainly to the content of fulvic acid, biologically degradable material and organic matter. Component 2 is related mainly to the content of tryptophan and humin from the higher vascular plants.
Diameter Tuning of β-Ga2O3 Nanowires Using Chemical Vapor Deposition Technique.
Kumar, Mukesh; Kumar, Vikram; Singh, R
2017-12-01
Diameter tuning of [Formula: see text]-Ga 2 O 3 nanowires using chemical vapor deposition technique have been investigated under various experimental conditions. Diameter of root grown [Formula: see text]-Ga 2 O 3 nanowires having monoclinic crystal structure is tuned by varying separation distance between metal source and substrate. Effect of gas flow rate and mixer ratio on the morphology and diameter of nanowires has been studied. Nanowire diameter depends on growth temperature, and it is independent of catalyst nanoparticle size at higher growth temperature (850-900 °C) as compared to lower growth temperature (800 °C). These nanowires show changes in structural strain value with change in diameter. Band-gap of nanowires increases with decrease in the diameter.
Brain Arterial Diameters as a Risk Factor for Vascular Events.
Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V
2015-08-06
Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score <-2 SDs were considered to have the smallest diameters, individuals with a BAR score >-2 and <2 SDs had average diameters, and individuals with a BAR score >2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
The longest wheal diameter is the optimal measurement for the evaluation of skin prick tests.
Konstantinou, George N; Bousquet, Philippe-Jean; Zuberbier, Torsten; Papadopoulos, Nikolaos G
2010-01-01
Mean diameter or longest diameter are the 2 most frequently used parameters for wheal response assessment after skin prick testing (SPT). We aimed to compare these 2 parameters taking as gold standard the surface of the wheal skin response. Patients suspected of having an allergic reaction against inhalant allergens have been skin prick tested using the Pan-European GA(2)LEN SPT panel. Fifteen minutes later, macroscopically evident wheal and flare reactions were marked with a pen and transferred to paper with a transparent scotch tape. Each paper-transferred wheal was scanned with an ordinary scanner, and its surface-corresponding maximum perpendicular diameters and longest diameters were measured using a computer software application for image recognition, developed for this purpose. Correlation coefficients (Spearman's rho) between surfaces and respective mean (rho(mean)) or longest (rho(longest)) diameters were calculated and subsequently compared. 1,554 SPTs were performed in 74 patients. In 264, a macroscopically evident wheal and flare response was observed. Both mean and longest diameters correlated significantly with the wheal surfaces. However, rho(longest) was statistically significantly larger than rho(mean) when the surface of the wheal was >17 mm(2) (rho(longest) > 0.860 vs. rho(mean) < 0.660; p < 0.05).Such a surface corresponds to a maximum diameter of approximately 7 mm and a mean diameter of approximately 6 mm. Thus, the larger the surface of the wheal, the more appropriate the usage of the longest diameter. The longest wheal diameter alone seems to be a better surrogate marker of the wheal surface in comparison with the mean diameter. In addition, it is easier and faster to measure. Therefore, we propose this as the optimal methodology to evaluate SPTs. 2009 S. Karger AG, Basel.
Michael T. Thompson; Maggie. Toone
2012-01-01
Tree diameter growth models are widely used in many forestry applications, often to predict tree size at a future point in time. Also, there are instances where projections of past diameters are needed. An individual tree model has been developed to estimate diameter growth of multi-stem woodland tree species where the diameter is measured at root collar. The model was...
Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang
2014-09-01
Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P < 0.001), higher CSFP (P < 0.001), and wider retinal veins (P = 0.001) or, as a corollary, with a higher vein-to-artery diameter ratio in multivariable analysis. Wider retinal vein diameters are associated with higher estimated CSFP and vice versa. In arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP, which is correlated with blood pressure. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Mercredi, Morgan; Vincent, Trevor J; Bidinosti, Christopher P; Martin, Melanie
2017-02-01
Current magnetic resonance imaging (MRI) axon diameter measurements rely on the pulsed gradient spin-echo sequence, which is unable to provide diffusion times short enough to measure small axon diameters. This study combines the AxCaliber axon diameter fitting method with data generated from Monte Carlo simulations of oscillating gradient spin-echo sequences (OGSE) to infer micron-sized axon diameters, in order to determine the feasibility of using MRI to infer smaller axon diameters in brain tissue. Monte Carlo computer simulation data were synthesized from tissue geometries of cylinders of different diameters using a range of gradient frequencies in the cosine OGSE sequence . Data were fitted to the AxCaliber method modified to allow the new pulse sequence. Intra- and extra-axonal water were studied separately and together. The simulations revealed the extra-axonal model to be problematic. Rather than change the model, we found that restricting the range of gradient frequencies such that the measured apparent diffusion coefficient was constant over that range resulted in more accurate fitted diameters. Thus a careful selection of frequency ranges is needed for the AxCaliber method to correctly model extra-axonal water, or adaptations to the method are needed. This restriction helped reduce the necessary gradient strengths for measurements that could be performed with parameters feasible for a Bruker BG6 gradient set. For these experiments, the simulations inferred diameters as small as 0.5 μm on square-packed and randomly packed cylinders. The accuracy of the inferred diameters was found to be dependent on the signal-to-noise ratio (SNR), with smaller diameters more affected by noise, although all diameter distributions were distinguishable from one another for all SNRs tested. The results of this study indicate the feasibility of using MRI with OGSE on preclinical scanners to infer small axon diameters.
Cutting Diameter Influences Early Survival and Growth of Several Populus Clones
Donald Dickmann; Howard Phipps; Daniel Netzer
1980-01-01
The effects of cutting diameter on early survival and growth of several Populus clones were studied in field tests in Wisconsin and Michigan. Generally, large diameter cuttings survived and grew better than small diameter cuttings. Response differences among clones were evident.
Gasser, T C; Nchimi, A; Swedenborg, J; Roy, J; Sakalihasan, N; Böckler, D; Hyhlik-Dürr, A
2014-03-01
To translate the individual abdominal aortic aneurysm (AAA) patient's biomechanical rupture risk profile to risk-equivalent diameters, and to retrospectively test their predictability in ruptured and non-ruptured aneurysms. Biomechanical parameters of ruptured and non-ruptured AAAs were retrospectively evaluated in a multicenter study. General patient data and high resolution computer tomography angiography (CTA) images from 203 non-ruptured and 40 ruptured aneurysmal infrarenal aortas. Three-dimensional AAA geometries were semi-automatically derived from CTA images. Finite element (FE) models were used to predict peak wall stress (PWS) and peak wall rupture index (PWRI) according to the individual anatomy, gender, blood pressure, intra-luminal thrombus (ILT) morphology, and relative aneurysm expansion. Average PWS diameter and PWRI diameter responses were evaluated, which allowed for the PWS equivalent and PWRI equivalent diameters for any individual aneurysm to be defined. PWS increased linearly and PWRI exponentially with respect to maximum AAA diameter. A size-adjusted analysis showed that PWS equivalent and PWRI equivalent diameters were increased by 7.5 mm (p = .013) and 14.0 mm (p < .001) in ruptured cases when compared to non-ruptured controls, respectively. In non-ruptured cases the PWRI equivalent diameters were increased by 13.2 mm (p < .001) in females when compared with males. Biomechanical parameters like PWS and PWRI allow for a highly individualized analysis by integrating factors that influence the risk of AAA rupture like geometry (degree of asymmetry, ILT morphology, etc.) and patient characteristics (gender, family history, blood pressure, etc.). PWRI and the reported annual risk of rupture increase similarly with the diameter. PWRI equivalent diameter expresses the PWRI through the diameter of the average AAA that has the same PWRI, i.e. is at the same biomechanical risk of rupture. Consequently, PWRI equivalent diameter facilitates a straightforward interpretation of biomechanical analysis and connects to diameter-based guidelines for AAA repair indication. PWRI equivalent diameter reflects an additional diagnostic parameter that may provide more accurate clinical data for AAA repair indication. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Characterization of fiber diameter using image analysis
NASA Astrophysics Data System (ADS)
Baheti, S.; Tunak, M.
2017-10-01
Due to high surface area and porosity, the applications of nanofibers have increased in recent years. In the production process, determination of average fiber diameter and fiber orientation is crucial for quality assessment. The objective of present study was to compare the relative performance of different methods discussed in literature for estimation of fiber diameter. In this work, the existing automated fiber diameter analysis software packages available in literature were developed and validated based on simulated images of known fiber diameter. Finally, all methods were compared for their reliable and accurate estimation of fiber diameter in electro spun nanofiber membranes based on obtained mean and standard deviation.
Vortex Ring Interaction With a Coaxially Aligned Cylinderical Rod
NASA Astrophysics Data System (ADS)
Arakeri, Jaywant H.; Rajmanoharan, P.; Koochesfahani, Manoochehr
1998-11-01
We present results of experiments of a fully developed vortex ring interacting with a cylinderical rod, having a rounded nose, placed coaxially in line with the motion of the ring. The pressure field of the translating ring causes unsteady boundary layer separation and results in the formation of one or more ( secondary ) vortex rings, that subsequently interact. The nature and strength of the interaction depends on the ratio of the cylinder diameter to the ring diameter. For the larger diameter cylinders the vortex ring travels a few ring diameters before it breaks up. For the smaller diameter cylinders the vortex ring speed decreases slowly and, simultaneously, its diameter increases.
NASA Astrophysics Data System (ADS)
Susanto, Sandi; Tjahjana, Dominicus Danardono Dwi Prija; Santoso, Budi
2018-02-01
Cross-flow wind turbine is one of the alternative energy harvester for low wind speeds area. Several factors that influence the power coefficient of cross-flow wind turbine are the diameter ratio of blades and the number of blades. The aim of this study is to find out the influence of the number of blades and the diameter ratio on the performance of cross-flow wind turbine and to find out the best configuration between number of blades and diameter ratio of the turbine. The experimental test were conducted under several variation including diameter ratio between outer and inner diameter of the turbine and number of blades. The variation of turbine diameter ratio between inner and outer diameter consisted of 0.58, 0.63, 0.68 and 0.73 while the variations of the number of blades used was 16, 20 and 24. The experimental test were conducted under certain wind speed which are 3m/s until 4 m/s. The result showed that the configurations between 0.68 diameter ratio and 20 blade numbers is the best configurations that has power coefficient of 0.049 and moment coefficient of 0.185.
D.A. Marquis
1991-01-01
Many studies have shown that initial tree diameter is closely correlated with subsequent tree growth. But initial tree diameter is actually a confounded variable, incorporating both competitive position (crown class) and age.
Fillinger, Mark F; Racusin, Jessica; Baker, Robert K; Cronenwett, Jack L; Teutelink, Arno; Schermerhorn, Marc L; Zwolak, Robert M; Powell, Richard J; Walsh, Daniel B; Rzucidlo, Eva M
2004-06-01
The purpose of this study was to analyze anatomic characteristics of patients with ruptured abdominal aortic aneurysms (AAAs), with conventional two-dimensional computed tomography (CT), including comparison with control subjects matched for age, gender, and size. Records were reviewed to identify all CT scans obtained at Dartmouth-Hitchcock Medical Center or referring hospitals before emergency AAA repair performed because of rupture or acute severe pain (RUP group). CT scans obtained before elective AAA repair (ELEC group) were reviewed for age and gender match with patients in the RUP group. More than 40 variables were measured on each CT scan. Aneurysm diameter matching was achieved by consecutively deleting the largest RUP scan and the smallest ELEC scan to prevent bias. CT scans were analyzed for 259 patients with AAAs: 122 RUP and 137 ELEC. Patients were well matched for age, gender, and other demographic variables or risk factors. Maximum AAA diameter was significantly different in comparisons of all patients (RUP, 6.5 +/- 2 cm vs ELEC, 5.6 +/- 1 cm; P <.0001), and mean diameter of ruptured AAAs was 5 mm smaller in female patients (6.1 +/- 2 cm vs 6.6 +/- 2 cm; P =.007). Two hundred patients were matched for diameter, gender, and age (100 from each group; maximum AAA diameter, 6.0 +/- 1 cm vs 6.0 +/- 1 cm). Analysis of diameter-matched AAAs indicated that most variables were statistically similar in the two groups, including infrarenal neck length (17 +/- 1 mm vs 19 +/- 1 mm; P =.3), maximum thrombus thickness (25 +/- 1 mm vs 23 +/- 1 mm, P =.4), and indices of body habitus, such as [(maximum AAA diameter)/(normal suprarenal aorta diameter)] or [(maximum AAA diameter)/(L3 transverse diameter)]. Multivariate analysis controlling for gender indicated that the most significant variables for rupture were aortic tortuosity (odds ratio [OR] 3.3, indicating greater risk with no or mild tortuosity), diameter asymmetry (OR, 3.2 for a 1-cm difference in major-minor axis), and current smoking (OR, 2.7, with the greater risk in current smokers). When matched for age, gender, and diameter, ruptured AAAs tend to be less tortuous, yet have greater cross-sectional diameter asymmetry. On conventional two-dimensional CT axial sections, it appears that when diameter asymmetry is associated with low aortic tortuosity, the larger diameter on axial sections more accurately reflects rupture risk, and when diameter asymmetry is associated with moderate or severe aortic tortuosity, the smaller diameter on axial sections more accurately reflects rupture risk. Current smoking is significantly associated with rupture, even when controlling for gender and AAA anatomy.
Tracheid diameter is the key trait determining the extent of freezing-induced embolism in conifers.
Pittermann, Jarmila; Sperry, John
2003-09-01
We tested the hypotheses that freezing-induced embolism is related to conduit diameter, and that conifers and angiosperms with conduits of equivalent diameter will exhibit similar losses of hydraulic conductivity in response to freezing. We surveyed the freeze-thaw response of conifers with a broad range of tracheid diameters by subjecting wood segments (root, stem and trunk wood) to a freeze-thaw cycle at -0.5 MPa in a centrifuge. Embolism increased as mean tracheid diameter exceeded 30 microm. Tracheids with a critical diameter greater than 43 microm were calculated to embolize in response to freezing and thawing at a xylem pressure of -0.5 MPa. To confirm that freezing-induced embolism is a function of conduit air content, we air-saturated stems of Abies lasiocarpa (Hook.) Nutt. (mean conduit diameter 13.7 +/- 0.7 microm) by pressurizing them 1 to 60 times above atmospheric pressure, prior to freezing and thawing. The air saturation method simulated the effect of increased tracheid size because the degree of super-saturation is proportional to a tracheid volume holding an equivalent amount of dissolved air at ambient pressure. Embolism increased when the dissolved air content was equivalent to a mean tracheid diameter of 30 microm at ambient air pressure. Our centrifuge and air-saturation data show that conifers are as vulnerable to freeze-thaw embolism as angiosperms with equal conduit diameter. We suggest that the hydraulic conductivity of conifer wood is maximized by increasing tracheid diameters in locations where freezing is rare. Conversely, the narrowing of tracheid diameters protects against freezing-induced embolism in cold climates.
NASA Astrophysics Data System (ADS)
Roth, Tanja; Sprenger, Lisa; Odenbach, Stefan; Häfeli, Urs O.
2018-04-01
Microfluidic spirals are able to focus non-spherical microparticles in diluted suspension due to the Dean effect. A secondary flow establishes in a curved channel, consisting of two counter-rotating vortices, which transport particles to an equilibrium position near the inner wall of the channel. The relevant size parameter, which is responsible for successful focusing, is the ratio between the particle diameter of a sphere and the hydraulic diameter, which is a characteristic of the microfluidic spiral. A non-spherical particle has not one but several different size parameters. This study investigated the minor and major axes, the equivalent spherical diameter, and the maximal rotational diameter as an equivalent to the spherical diameter. Using a polydimethylsiloxane (PDMS)-based microfluidic device with spirals, experiments were conducted with artificial peanut-shaped and ellipsoidal particles sized between 3 and 9 μm as well as with the bacteria Bacillus subtilis. Our investigations show that the equivalent spherical diameter, the major axis, and the maximal rotational diameter of a non-spherical particle can predict successful focusing. The minor axis is not suitable for this purpose. Non-spherical particles focused when the ratio of their equivalent spherical diameter to the hydraulic diameter of the channel was larger than 0.07. The particles also focused when the ratio between the maximal rotational diameter or the major axis and the hydraulic diameter was larger than 0.01. These results may help us to separate non-spherical biological particles, such as circulating tumor cells or pathogenic bacteria, from blood in future experimental studies.
Assessment of the Effect of Blast Hole Diameter on the Number of Oversize Boulders Using ANN Model
NASA Astrophysics Data System (ADS)
Dhekne, Prakash; Pradhan, Manoj; Jade, Ravi Krishnarao
2016-04-01
Now-a-days, blasts are planned using large diameter blast holes. The loading density (kg/m) and subsequently the energy available for the breakage of the rockmass increase with the diameter. The in-hole velocity of detonation (VoD) of non-ideal explosive also boosts up with the increase in diameter till the optimum diameter is reached. The increase in the energy content and in-hole VoD cause a sizable effect on the rock fragmentation. The effect can be assessed by counting the number of oversize boulders. This paper explains as to how the technique of artificial neural network modeling was used to predict the number of oversize boulders resulting from ANFO and SME blasts with blast holes of different diameters. The results from ANFO blasts indicated that there was no significant variation in the number of oversize boulders with the diameter whereas a perceptible variation was noticed in case of SME blasts with the change in the diameter. The change in the number of oversize boulders in ANFO blasts was negligible because mean energy factor remained almost same even when the diameter of the blast holes was altered. The decrease in the number of oversize boulders in SME blasts was on account of increase in mean energy factor when the blast hole diameter was increased. The increase in the in-hole VoD due to increase in the diameter of the hole was not found to have an effect on the generation of oversize boulders as this increase was not substantial both in SME and ANFO blasts.
Extrusion of small-diameter, thin-wall tungsten tubing
NASA Technical Reports Server (NTRS)
Blankenship, C. P.; Gyorgak, C. A.
1967-01-01
Small-diameter, thin-wall seamless tubing of tungsten has been fabricated in lengths of up to 10 feet by hot extrusion over a floating mandrel. Extrusion of 0.50-inch-diameter tubing over 0.4-inch-diameter mandrels was accomplished at temperatures ranging from 3000 degrees to 4000 degrees F.
76 FR 9608 - Certain Welded Large Diameter Line Pipe From Mexico
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-18
... Large Diameter Line Pipe From Mexico AGENCY: United States International Trade Commission. ACTION... duty order on certain welded large diameter line pipe from Mexico. For further information concerning... welded large diameter line pipe from Mexico would not be likely to lead to continuation or recurrence of...
Remarks on Height-Diameter Modeling
Lei Yuancai; Bernard R. Parresol
2001-01-01
Height-diameter model forms in earlier published papers are examined. The selection criteria used in height-diameter model forms are not reasonable when considering tree biological growth pattern. During model selection, forms for height-diameter relationships should include consideration of both data-related and reasonable biological criteria, not just data-related...
Floyd A. Johnson
1956-01-01
Whenever past diameters of ponderosa pine trees are required for growth studies or for other purposes they can be estimated with these formulas: (1) trees 10 inches and over in diameter at breast height Dp=Dn - Wg (1.121) Where Dp...
D.b.h./crown diameter relationships in mixed Appalachian hardwood stands
Neil I. Lamson; Neil I. Lamson
1987-01-01
Linear regression formulae for predicting crown diameter as a function of stem diameter are presented for nine species found in 50- to 80-year-old mixed hardwood stands in north-central West Virginia. Generally, crown diameter was closely related to tolerance; more tolerant species had larger crowns.
Electronic transport behavior of diameter-graded Ag nanowires
NASA Astrophysics Data System (ADS)
Wang, Xue Wei; Yuan, Zhi Hao
2010-05-01
Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menikoff, Ralph
Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).
Apparatus for measuring surface particulate contamination
Woodmansee, Donald E.
2002-01-01
An apparatus for measuring surface particulate contamination includes a tool for collecting a contamination sample from a target surface, a mask having an opening of known area formed therein for defining the target surface, and a flexible connector connecting the tool to the mask. The tool includes a body portion having a large diameter section defining a surface and a small diameter section extending from the large diameter section. A particulate collector is removably mounted on the surface of the large diameter section for collecting the contaminants. The tool further includes a spindle extending from the small diameter section and a spool slidingly mounted on the spindle. A spring is disposed between the small diameter section and the spool for biasing the spool away from the small diameter section. An indicator is provided on the spindle so as to be revealed when the spool is pressed downward to compress the spring.
Room temperature synthesis and optical properties of small diameter (5 nm) ZnO nanorod arrays.
Cho, Seungho; Jang, Ji-Wook; Lee, Jae Sung; Lee, Kun-Hong
2010-10-01
We report a simple wet-chemical synthesis of ∼5 nm diameter ZnO nanorod arrays at room temperature (20 °C) and normal atmospheric pressure (1 atm) and their optical properties. They were single crystalline in nature, and grew in the [001] direction. These small diameter ZnO nanorod arrays can also be synthesized at 0 °C. Control experiments were also conducted. On the basis of the results, we propose a mechanism for the spontaneous growth of the small diameter ZnO structures. The optical properties of the 5 nm diameter ZnO nanorod arrays synthesized using this method were probed by UV-Visible diffuse reflectance spectroscopy. A clear blue-shift, relative to the absorption band from 50 nm diameter ZnO nanorod arrays, was attributed to the quantum confinement effects caused by the small nanocrystal size in the 5 nm diameter ZnO nanorods.
Dimensions of stabident intraosseous perforators and needles.
Ramlee, R A; Whitworth, J
2001-09-01
Problems can be encountered inserting intraosseous injection needles through perforation sites. This in vitro study examined the variability and size compatibility of Stabident intraosseous injection components. The diameters of 40 needles and perforators from a single Stabident kit were measured in triplicate with a toolmakers microscope. One-way ANOVA revealed that mean needle diameter (0.411 mm) was significantly narrower than mean perforator diameter (0.427 mm) (p < 0.001). A frequency distribution plot revealed that needle diameter followed a normal distribution, indicating tight quality control during manufacture. The diameter of perforators was haphazardly distributed, with a clustering of 15% at the lower limit of the size range. However on no occasion was the diameter of a perforator smaller than that of an injection needle. We conclude that components of the Stabident intraosseous anaesthetic system are size-compatible, but there is greater and more haphazard variability in the diameter of perforators than injection needles.
29 CFR 1910.211 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... having a diameter, thickness and wall—wheel is mounted on the diameter. (3) Type 6 straight cup wheels...—Type 6 Straight Cup Wheels EC27OC91.054 Type 6—Straight-cup Wheel Side grinding wheel having a diameter... describe this shape type. (4) Type 11 flaring cup wheels mean wheels having double diameter dimensions D...
Height prediction equations for even-aged upland oak stands
Donald E. Hilt; Martin E. Dale
1982-01-01
Forest growth models that use predicted tree diameters or diameter distributions require a reliable height-prediction model to obtain volume estimates because future height-diameter relationships will not necessarily be the same as the present height-diameter relationship. A total tree height prediction equation for even-aged upland oak stands is presented. Predicted...
Comprehensive database of diameter-based biomass regressions for North American tree species
Jennifer C. Jenkins; David C. Chojnacky; Linda S. Heath; Richard A. Birdsey
2004-01-01
A database consisting of 2,640 equations compiled from the literature for predicting the biomass of trees and tree components from diameter measurements of species found in North America. Bibliographic information, geographic locations, diameter limits, diameter and biomass units, equation forms, statistical errors, and coefficients are provided for each equation,...
Tree diameter at breast height in relation to stump diameter by species group
Arthur G. Horn; Richard C. Keller
1957-01-01
A stump tally is one method of determining the volume of timber previously removed from an area in a logging operation. To estimate volume of standing timber from stumps, foresters must first know the relationship between stump diameters and tree diameters at breast height (d.b.h.).
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-21
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-929] Small Diameter Graphite... antidumping duty order on small diameter graphite electrodes from the People's Republic of China (``PRC'') for... preliminary results of this review were published on March 7, 2011. See Small Diameter Graphite Electrodes...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-07
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-929] Small Diameter Graphite... Department) initiated an administrative review of the antidumping duty order on small diameter graphite... preliminary results of this review by 95 days until February 3, 2012. See Small Diameter Graphite Electrodes...
Investigation of the depth and diameter relationship of subkilometer-diameter lunar craters
NASA Astrophysics Data System (ADS)
Sun, Shujuan; Yue, Zongyu; Di, Kaichang
2018-07-01
The depth and diameter relationship is one of the most important characteristics of craters; however, previous studies have focused mostly on large-diameter craters because of the limitations of image resolution. Recently, very high resolution images have been obtained that make it possible to expand this field of study to craters with diameters of < 1 km. Using images with resolution of up to 0.5 m, acquired by the Lunar Reconnaissance Orbiter, we investigated the depth and diameter relationship of fresh craters with subkilometer diameters. We selected craters from lunar maria and highlands, and we made precise measurements of their diameters and depths. The results show that the d/D ratio of small craters in the lunar maria and highlands, which varies from ∼0.2 to ∼0.1, is generally shallower than that of larger craters. We propose that the reason for the difference is because of the low strength of the lunar surface material. The fitted power law parameters of lunar mare and highland craters were found to be different, and that might be explained by terrain-related differences.
Araujo Júnior, Edward; Martins, Wellington P; Nardozza, Luciano Marcondes Machado; Pires, Claudio Rodrigues; Filho, Sebastião Marques Zanforlin
2015-02-01
To determine a reference range of fetal transverse cerebellar diameter in Brazilian population. This was a retrospective cross-sectional study with 3772 normal singleton pregnancies between 18 and 24 weeks of pregnancy. The transverse cerebellar diameter was measured on the axial plane of the fetal head at the level of the lateral ventricles, including the thalamus, cavum septum pellucidum, and third ventricle. To assess the correlation between transverse cerebellar diameter and gestational age, polynomial equations were calculated, with adjustments by the determination coefficient (R2). The mean of fetal transverse cerebellar diameter ranged from 18.49 ± 1.24 mm at 18 weeks to 25.86 ± 1.66 mm at 24 weeks of pregnancy. We observed a good correlation between transverse cerebellar diameter and gestational age, which was best represented by a linear equation: transverse cerebellar diameter: -6.21 + 1.307*gestational age (R2 = 0.707). We determined a reference range of fetal transverse cerebellar diameter for the second trimester of pregnancy in Brazilian population. © The Author(s) 2014.
Common iliac artery aneurysms in patients with abdominal aortic aneurysms.
Armon, M P; Wenham, P W; Whitaker, S C; Gregson, R H; Hopkinson, B R
1998-03-01
To determine the incidence of common iliac artery (CIA) aneurysms in patients with abdominal aortic aneurysms (AAA) and to evaluate the relationship between AAA and CIA diameter. Spiral CT angiography was used to measure the maximum diameters of the abdominal aorta and the common iliac arteries of 215 patients with AAA. The median CIA diameter was 1.7 cm--significantly greater than the published mean of 1.25 (2 S.D. = 0.85-1.65) cm of an age-matched, non-vascular population. Thirty-four patients (16%) had unilateral and 26 patients (12%) bilateral CIA aneurysms > or = 2.4 cm diameter. Eight-six vessels (20%) were affected. Right CIA diameters were wider than left CIA diameters (p < 0.0001, Wilcoxon matched-pairs signed rank test). The correlation between AAA size and CIA diameter was weak. The AAA population has abnormally dilated common iliac arteries. In this population, common iliac artery aneurysms should be defined as those greater than 2.4 cm diameter. 20% of CIAs in patients with AAA are aneurysmal according to this definition.
NASA Technical Reports Server (NTRS)
Moore, C S; Collins, J H
1932-01-01
Results of motoring tests are presented showing the effect of passage diameter on chamber and cylinder compression pressures, maximum pressure differences, and f.m.e.p. over a speed range from 300 to 1,750 r.p.m. Results of engine performance tests are presented which show the effect of passage diameter on m.e.p., explosion pressures, specific fuel consumption, and rates of pressure rise for a range of engine speeds from 500 to 1,500 r.p.m. The cylinder compression pressure, the maximum pressure difference, and the f.m.e.p. decreased rapidly as the passage diameter increased to 29/64 inch, whereas further increase in passage diameter effected only a slight change. The most suitable passage diameter for good engine performance and operating characteristics was 29/64 inch. Passage diameter became less critical with a decrease in engine speed. Therefore, the design should be based on maximum operating speed. Optimum performance and satisfactory combustion control could not be obtained by means of any single diameter of the connecting passage.
Mirmohammadi, Hesam; Sitarz, Monika; Shemesh, Hagay
2018-01-01
Manufacturers offer gutta-percha (GP) cones matched with different sizes of endodontic files as an attempt to simplify the obturation process and create a tight seal in the canal. The purpose of this study was to evaluate whether intra-manufacture GP diameters matched the diameters of their corresponding files at different levels using laser micrometre. Twenty files and corresponding GP master cones of Reciproc R40 (40/0.06) (VDW, Munich, Germany), WaveOne Large(40/0.08)(Dentsply Maillefer, Ballaigues, Switzerland), ProTaper F3 (30/0.09) (Dentsply Maillefer, Ballaigues, Switzerland), and Mtwo 40/0.06 (VDW, Munich, Germany) were examined using laser micrometre (LSM 6000 by Mitutoyo, Japan) with accuracy of 1 nm to establish their actual diameter at D 0 , D 1 , D 3 and D 6 . The data was analysed using the independent t -test. The differences were considered at 0.05. The diameter of GP master cones was significantly larger than that of the corresponding files at all levels in all brands. ProTaper GP diameter was closest to the file diameter at D1 (GP=0.35, File=0.35 mm), and D3 (GP=0.48, File=0.49). Within the same manufacturer, GP cone diameters do not match the diameters of their corresponding files. Clinicians are advised to use a GP gauge to cut the tip so as to appropriate the diameter from a smaller sized GP cone.
Yang, Ruiqi; Wang, Fei; Zhang, Jialing; Zhu, Chonglei; Fan, Limei
2015-05-19
To establish the reference values of thalamus, caudate nucleus and lenticular nucleus diameters through fetal thalamic transverse section. A total of 265 fetuses at our hospital were randomly selected from November 2012 to August 2014. And the transverse and length diameters of thalamus, caudate nucleus and lenticular nucleus were measured. SPSS 19.0 statistical software was used to calculate the regression curve of fetal diameter changes and gestational weeks of pregnancy. P < 0.05 was considered as having statistical significance. The linear regression equation of fetal thalamic length diameter and gestational week was: Y = 0.051X+0.201, R = 0.876, linear regression equation of thalamic transverse diameter and fetal gestational week was: Y = 0.031X+0.229, R = 0.817, linear regression equation of fetal head of caudate nucleus length diameter and gestational age was: Y = 0.033X+0.101, R = 0.722, linear regression equation of fetal head of caudate nucleus transverse diameter and gestational week was: R = 0.025 - 0.046, R = 0.711, linear regression equation of fetal lentiform nucleus length diameter and gestational week was: Y = 0.046+0.229, R = 0.765, linear regression equation of fetal lentiform nucleus diameter and gestational week was: Y = 0.025 - 0.05, R = 0.772. Ultrasonic measurement of diameter of fetal thalamus caudate nucleus, and lenticular nucleus through thalamic transverse section is simple and convenient. And measurements increase with fetal gestational weeks and there is linear regression relationship between them.
Ho, Sean Wei Loong; Tan, Teong Jin Lester; Lee, Keng Thiam
2016-03-01
To evaluate whether pre-operative anthropometric data can predict the optimal diameter and length of hamstring tendon autograft for anterior cruciate ligament (ACL) reconstruction. This was a cohort study that involved 169 patients who underwent single-bundle ACL reconstruction (single surgeon) with 4-stranded MM Gracilis and MM Semi-Tendinosus autografts. Height, weight, body mass index (BMI), gender, race, age and -smoking status were recorded pre-operatively. Intra-operatively, the diameter and functional length of the 4-stranded autograft was recorded. Multiple regression analysis was used to determine the relationship between the anthropometric measurements and the length and diameter of the implanted autografts. The strongest correlation between 4-stranded hamstring autograft diameter was height and weight. This correlation was stronger in females than males. BMI had a moderate correlation with the diameter of the graft in females. Females had a significantly smaller graft both in diameter and length when compared with males. Linear regression models did not show any significant correlation between hamstring autograft length with height and weight (p>0.05). Simple regression analysis demonstrated that height and weight can be used to predict hamstring graft diameter. The following regression equation was obtained for females: Graft diameter=0.012+0.034*Height+0.026*Weight (R2=0.358, p=0.004) The following regression equation was obtained for males: Graft diameter=5.130+0.012*Height+0.007*Weight (R2=0.086, p=0.002). Pre-operative anthropometric data has a positive correlation with the diameter of 4 stranded hamstring autografts but no significant correlation with the length. This data can be utilised to predict the autograft diameter and may be useful for pre-operative planning and patient counseling for graft selection.
Influence of Age and Apical Diameter on the Success of Endodontic Regeneration Procedures.
Estefan, Bishoy Safwat; El Batouty, Kariem Mostafa; Nagy, Mohamed Mokhtar; Diogenes, Anibal
2016-11-01
Treatment of immature permanent teeth with necrotic pulp and apical pathosis constitutes a challenge for endodontists. The present study was done to evaluate the effect of age and apical diameter on the regenerative potential of young permanent immature teeth with necrotic pulps. Immature necrotic permanent maxillary incisors (n = 40) of patients 9-18 years old were divided into 2 groups according to the treatment protocol: group Y (younger age group), 9-13 years and group O (older age group), 14-18 years. Each group was further subdivided into 2 subgroups according to apical diameter, subgroup (n) (narrower diameter) between 0.5 and 1 mm and subgroup (w) (wider diameter) equal to or greater than 1 mm. Revascularization procedures were performed for all patients. Follow-up was done for up to 12 months. Standardized radiographs were digitally evaluated for increase in root length and thickness and decrease in apical diameter. After the follow-up period, most of the cases demonstrated radiographic evidence of periapical healing. Group Y showed significant progressive increase in root length and width and decrease in apical diameter. Subgroup (w) representing wider apical diameter showed significant progress as well. It was found that revascularization procedures can be implemented in any age ranging from 9 to 18 years; however, younger age groups were better candidates for revascularization procedure than older ones. Regarding the apical diameter, regeneration procedures were successful with apical diameters as small as 0.5 mm. However, teeth with preoperative wider diameters (≥1 mm) demonstrated greater increase in root thickness, length, and apical narrowing. Copyright © 2016 American Association of Endodontists. All rights reserved.
Schwarzwald, Colin C; Jenni, Rolf
2009-01-01
Background Natural heterologous valved conduits with a diameter greater than 22 mm that can be used for right ventricular outflow tract reconstruction in adults are not commercially available. The purpose of this study was to measure by ultrasonography the maximum diameter of the distended jugular veins of horses and cattle, respectively, to identify a population of animals that would be suitable for post-mortem collection of jugular veins at sizes greater than 22 mm. Methods The study population included 60 Warmblood horses, 25 Freiberger horses, 20 Brown Swiss cows, and 20 Holstein cows (including 10 Holstein and 10 Red Holstein). The maximum cross-sectional diameter of the distended jugular veins was measured at a location half-way between the mandibular angle and the thoracic inlet. The thoracic circumference (heart girth length) was used as a surrogate of body size. The jugular vein diameters of the different populations were compared by analysis of variance and the association between heart girth length and jugular vein diameter was determined in each of the four study populations by linear regression analysis. Results There was considerable individual variation of jugular vein diameters within each of the four study populations. There was no statistically significant relationship between thoracic circumference and jugular vein diameter in any of the populations. The jugular vein diameters of Brown Swiss cows were significantly larger than those of any of the other populations. Warmblood horses had significantly larger jugular vein diameters compared to Freiberger horses. Conclusion The results of this study suggest that the production of bovine or equine xenografts with diameters of greater than 22 mm would be feasible. Differences between species and breeds need to be considered. However, prediction of the jugular vein diameter based on breed and heart girth length in an individual animal is inaccurate. PMID:19678940
Ecological Importance of Large-Diameter Trees in a Temperate Mixed-Conifer Forest
Lutz, James A.; Larson, Andrew J.; Swanson, Mark E.; Freund, James A.
2012-01-01
Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. Although both scaling theory and competition theory make predictions about the relative composition and spatial patterns of large-diameter trees compared to smaller diameter trees, these predictions are rarely tested. We established a 25.6 ha permanent plot within which we tagged and mapped all trees ≥1 cm dbh, all snags ≥10 cm dbh, and all shrub patches ≥2 m2. We sampled downed woody debris, litter, and duff with line intercept transects. Aboveground live biomass of the 23 woody species was 507.9 Mg/ha, of which 503.8 Mg/ha was trees (SD = 114.3 Mg/ha) and 4.1 Mg/ha was shrubs. Aboveground live and dead biomass was 652.0 Mg/ha. Large-diameter trees comprised 1.4% of individuals but 49.4% of biomass, with biomass dominated by Abies concolor and Pinus lambertiana (93.0% of tree biomass). The large-diameter component dominated the biomass of snags (59.5%) and contributed significantly to that of woody debris (36.6%). Traditional scaling theory was not a good model for either the relationship between tree radii and tree abundance or tree biomass. Spatial patterning of large-diameter trees of the three most abundant species differed from that of small-diameter conspecifics. For A. concolor and P. lambertiana, as well as all trees pooled, large-diameter and small-diameter trees were spatially segregated through inter-tree distances <10 m. Competition alone was insufficient to explain the spatial patterns of large-diameter trees and spatial relationships between large-diameter and small-diameter trees. Long-term observations may reveal regulation of forest biomass and spatial structure by fire, wind, pathogens, and insects in Sierra Nevada mixed-conifer forests. Sustaining ecosystem functions such as carbon storage or provision of specialist species habitat will likely require different management strategies when the functions are performed primarily by a few large trees as opposed to many smaller trees. PMID:22567132
NASA Astrophysics Data System (ADS)
Bergin, Stephen M.; Chen, Yu-Hui; Rathmell, Aaron R.; Charbonneau, Patrick; Li, Zhi-Yuan; Wiley, Benjamin J.
2012-03-01
This article describes how the dimensions of nanowires affect the transmittance and sheet resistance of a random nanowire network. Silver nanowires with independently controlled lengths and diameters were synthesized with a gram-scale polyol synthesis by controlling the reaction temperature and time. Characterization of films composed of nanowires of different lengths but the same diameter enabled the quantification of the effect of length on the conductance and transmittance of silver nanowire films. Finite-difference time-domain calculations were used to determine the effect of nanowire diameter, overlap, and hole size on the transmittance of a nanowire network. For individual nanowires with diameters greater than 50 nm, increasing diameter increases the electrical conductance to optical extinction ratio, but the opposite is true for nanowires with diameters less than this size. Calculations and experimental data show that for a random network of nanowires, decreasing nanowire diameter increases the number density of nanowires at a given transmittance, leading to improved connectivity and conductivity at high transmittance (>90%). This information will facilitate the design of transparent, conducting nanowire films for flexible displays, organic light emitting diodes and thin-film solar cells.This article describes how the dimensions of nanowires affect the transmittance and sheet resistance of a random nanowire network. Silver nanowires with independently controlled lengths and diameters were synthesized with a gram-scale polyol synthesis by controlling the reaction temperature and time. Characterization of films composed of nanowires of different lengths but the same diameter enabled the quantification of the effect of length on the conductance and transmittance of silver nanowire films. Finite-difference time-domain calculations were used to determine the effect of nanowire diameter, overlap, and hole size on the transmittance of a nanowire network. For individual nanowires with diameters greater than 50 nm, increasing diameter increases the electrical conductance to optical extinction ratio, but the opposite is true for nanowires with diameters less than this size. Calculations and experimental data show that for a random network of nanowires, decreasing nanowire diameter increases the number density of nanowires at a given transmittance, leading to improved connectivity and conductivity at high transmittance (>90%). This information will facilitate the design of transparent, conducting nanowire films for flexible displays, organic light emitting diodes and thin-film solar cells. Electronic supplementary information (ESI) available: Includes methods and transmission spectra of nanowire films. See DOI: 10.1039/c2nr30126a
DSTO Landmine Detection Test Targets
2005-06-01
cm diameter, 10 cm high. x x GS 32D50 Galvanised steel, pipe, hollow, 32 cm diameter, 50 cm long, ends capped x x GS 45D50 Galvanised Steel, pipe...hollow, 45 cm diameter, 50 cm long, ends capped x x GS 75D50 Galvanised Steel, pipe, hollow, 75 cm diameter, 50 cm long, ends capped x x
Jamie C. Schexnayder; Thomas J. Dean; V. Clark Baldwin
2002-01-01
Abstract - In 1994, a 17-year old, slash pine (Pinus elliottii var. elliottii) spacing study was thinned to evaluate the influence of prethinning stand conditions on diameter growth after thinning. Diameter growth and crown dimensions measured just prior to thinning showed that diameter growth was positively...
Regional height-diameter equations for major tree species of southwest Oregon.
H. Temesgen; D.W. Hann; V.J. Monleon
2006-01-01
Selected tree height and diameter functions were evaluated for their predictive abilities for major tree species of southwest Oregon. The equations included tree diameter alone, or diameter plus alternative measures of stand density and relative position. Two of the base equations were asymptotic functions, and two were exponential functional forms. The inclusion of...
The Effect of Density on the Height-Diameter Relationship
Boris Zeide; Curtis Vanderschaaf
2002-01-01
Using stand density along with mean diameter to predict average height increases the proportion of explained variance. This result, obtained from permanent plots established in a loblolly pine plantation thinned to different levels, makes sense. We know that due to competition, trees with the same diameter are taller in denser stands. Diameter and density are not only...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-22
... Administration [A-588-857] Welded Large Diameter Line Pipe From Japan: Notice of Rescission of Antidumping Duty... Japan. The review covers five producers/exporters of welded large diameter line pipe from Japan, which... diameter line pipe from Japan for the period December 1, 2010, through November 30, 2011. See Antidumping...
Modeling individual tree growth by fusing diameter tape and increment core data
Erin M. Schliep; Tracy Qi Dong; Alan E. Gelfand; Fan. Li
2014-01-01
Tree growth estimation is a challenging task as difficulties associated with data collection and inference often result in inaccurate estimates. Two main methods for tree growth estimation are diameter tape measurements and increment cores. The former involves repeatedly measuring tree diameters with a cloth or metal tape whose scale has been adjusted to give diameter...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rigali, Mark J.; Pye, Steven; Hardin, Ernest
This study considers the feasibility of large diameter deep boreholes for waste disposal. The conceptual approach considers examples of deep large diameter boreholes that have been successfully drilled, and also other deep borehole designs proposed in the literature. The objective for large diameter boreholes would be disposal of waste packages with diameters of 22 to 29 inches, which could enable disposal of waste forms such as existing vitrified high level waste. A large-diameter deep borehole design option would also be amenable to other waste forms including calcine waste, treated Na-bonded and Na-bearing waste, and Cs and Sr capsules.
Method and apparatus for determining diameter and wall thickness of minute hollow spherical shells
Steinman, D.A.
1980-05-30
Method and apparatus for determining diameter and wall thickness of hollow microspheres or shells wherein terminal velocities of shells traveling in fluid-filled conduits of differing diameters are measured. A wall-effect factor is determined as a ratio of the terminal velocities, and shell outside diameter may then be ascertained as a predetermined empirical function of wall-effect factor. For shells of known outside diameter, wall thickness may then be ascertained as a predetermined empirical function of terminal velocity in either conduit.
Method and apparatus for determining diameter and wall thickness of minute hollow spherical shells
Steinman, David A.
1982-01-01
Method and apparatus for determining diameter and wall thickness of hollow microspheres or shells wherein terminal velocities of shells traveling in fluid-filled conduits of differing diameters are measured. A wall-effect factor is determined as a ratio of the terminal velocities, and shell outside diameter may then be ascertained as a predetermined empirical function of wall-effect factor. For shells of known outside diameter, wall thickness may then be ascertained as a predetermined empirical function of terminal velocity in either conduit.
Lysosome Transport as a Function of Lysosome Diameter
Bandyopadhyay, Debjyoti; Cyphersmith, Austin; Zapata, Jairo A.; Kim, Y. Joseph; Payne, Christine K.
2014-01-01
Lysosomes are membrane-bound organelles responsible for the transport and degradation of intracellular and extracellular cargo. The intracellular motion of lysosomes is both diffusive and active, mediated by motor proteins moving lysosomes along microtubules. We sought to determine how lysosome diameter influences lysosome transport. We used osmotic swelling to double the diameter of lysosomes, creating a population of enlarged lysosomes. This allowed us to directly examine the intracellular transport of the same organelle as a function of diameter. Lysosome transport was measured using live cell fluorescence microscopy and single particle tracking. We find, as expected, the diffusive component of intracellular transport is decreased proportional to the increased lysosome diameter. Active transport of the enlarged lysosomes is not affected by the increased lysosome diameter. PMID:24497985
NASA Astrophysics Data System (ADS)
Kondo, Daiyu; Sato, Shintaro; Awano, Yuji
2006-05-01
Single-walled carbon nanotubes (SWNTs) with a narrow diameter distribution have been synthesized by hot-filament chemical vapor deposition using acetylene at 590 °C. Iron nanoparticles with diameters of 1.6, 2.0, 2.5, 5.0 and 10 nm (standard deviation: ≈10%) obtained with a differential mobility analyzer were used as a catalyst without any supporting materials on a substrate. SWNTs were obtained from 2.0 nm or smaller particles. The ratio of G band to D band in Raman spectra was as high as 35 without purification, indicating that high-quality SWNTs were synthesized. The SWNT diameters correlated with the particle diameters, demonstrating diameter-controlled SWNT growth.
Geleto, Gemechu; Getnet, Wondim; Tewelde, Tsegaye
2016-05-01
Mean portal vein diameter is considered as the best indicator for portal hypertension. However, the cutoff point differs from study to study (above 10-15 mm) despite the existence of normal mean portal vein diameter between 10-15 mm in different settings.This implies the existence of limited evidence on normal portal vein diameter for all populations in all countries prior to setting the cutoff points. Therefore, the aim of this study was sonographic assessment of normal mean portal vein diameter among patients referred to The Department of Radiology in Jimma University Hospital. A facility based cross-sectional study was conducted from November to December 2014 at Jimma University Hospital on a total of 195 clients. Data about portal vein diameter for eligible clients were collected by radiologists using Sonography. Data were edited manually, entered and analyzed using SPSS version 16. Data were collected from a total of 195 participants. Among these, 121(62.1%) were males and the median age of the participants was 35 years. The study revealed a normal mean portal vein diameter of 10.6 mm ±1.8 SD with a respirophasic variation of 25.6%. Likewise, the normal mean portal vein diameter seemed to have varied significantly by age and sex. The study revealed a normal mean portal vein diameter ranging below 13 mm. Hence, decisions made in clinical settings should base on these findings. Besides, there is a need for large scale study to determine portal vein diameter variation by age and sex, controlling other confounders.
NASA Astrophysics Data System (ADS)
Zhang, Guoqiang; Tateno, Kouta; Sogawa, Tetsuomi; Gotoh, Hideki
2018-04-01
We report diameter-tailored luminescence in telecom band of InP/InAs multi-heterostructure nanowires with continuously-modulated diameter from microscale to nanoscale. By using the self-catalyzed vapor-solid-liquid approach, we tune the indium particle size, and consequently the InP/InAs nanowire diameter, during growth by modulating the flow rate of the indium source material. This technique allows a high degree of continuous tuning in a wide scale from microscale to nanoscale. Hence it offers an original way to bridge the gap between microscale-featured photolithographic and nanoscale-featured nanolithographic processes and to incorporate InAs quantum disks with tunable diameters into a single InP/InAs quantum heterostructure nanowire. We realized site-defined nanowires with nanoscale diameters initiated from site-defined microscale-diameter particles made with a conventional photolithographic process. The luminescence wavelength from InAs quantum disks is directly connected to the nanowire diameter, by which the strain in the InAs quantum disks is tailored. This work provides new opportunities in the fabrication and design of nanowire devices that extends beyond what is achievable with the current technologies and enables the nanowire shape to be engineered thus offering the potential to broaden the application range of nanowire devices.
Zhang, Guoqiang; Tateno, Kouta; Sogawa, Tetsuomi; Gotoh, Hideki
2018-04-02
We report diameter-tailored luminescence in telecom band of InP/InAs multi-heterostructure nanowires with continuously-modulated diameter from microscale to nanoscale. By using the self-catalyzed vapor-solid-liquid approach, we tune the indium particle size, and consequently the InP/InAs nanowire diameter, during growth by modulating the flow rate of the indium source material. This technique allows a high degree of continuous tuning in a wide scale from microscale to nanoscale. Hence it offers an original way to bridge the gap between microscale-featured photolithographic and nanoscale-featured nanolithographic processes and to incorporate InAs quantum disks with tunable diameters into a single InP/InAs quantum heterostructure nanowire. We realized site-defined nanowires with nanoscale diameters initiated from site-defined microscale-diameter particles made with a conventional photolithographic process. The luminescence wavelength from InAs quantum disks is directly connected to the nanowire diameter, by which the strain in the InAs quantum disks is tailored. This work provides new opportunities in the fabrication and design of nanowire devices that extends beyond what is achievable with the current technologies and enables the nanowire shape to be engineered thus offering the potential to broaden the application range of nanowire devices.
Williams, Jackie M.; Krebs, Ingar A.; Riedesel, Elizabeth A.; Zhao, Qianqian
2015-01-01
Tracheal collapse is a progressive airway disease that can ultimately result in complete airway obstruction. Intraluminal tracheal stents are a minimally invasive and viable treatment for tracheal collapse once the disease becomes refractory to medical management. Intraluminal stent size is chosen based on the maximum measured tracheal diameter during maximum inflation. The purpose of this prospective, cross-sectional study was to compare tracheal lumen diameter measurements and subsequent selected stent size using both fluoroscopy and CT and to evaluate inter- and intraobserver variability of the measurements. Seventeen healthy Beagles were anesthetized and imaged with fluoroscopy and CT with positive pressure ventilation to 20 cm H2O. Fluoroscopic and CT maximum tracheal diameters were measured by 3 readers. Three individual measurements were made at 8 pre-determined tracheal sites for dorsoventral (height) and laterolateral (width) dimensions. Tracheal diameters and stent sizes (based on the maximum tracheal diameter + 10%) were analyzed using a linear mixed model. CT tracheal lumen diameters were larger compared to fluoroscopy at all locations. When comparing modalities, fluoroscopic and CT stent sizes were statistically different. Greater overall variation in tracheal diameter measurement (height or width) existed for fluoroscopy compared to CT, both within and among observers. The greater tracheal diameter and lower measurement variability supported the use of CT for appropriate stent selection to minimize complications in veterinary patients. PMID:26784924
Diametric Quadrilaterals with Two Equal Sides
ERIC Educational Resources Information Center
Beauregard, Raymond A.
2009-01-01
If you take a circle with a horizontal diameter and mark off any two points on the circumference above the diameter, then these two points together with the end points of the diameter form the vertices of a cyclic quadrilateral with the diameter as one of the sides. We refer to the quadrilaterals in question as diametric. In this note we consider…
Feasibility of utilizing small diameter southern pine for biomass in the Virginia Coastal Plain
Nathan C. Hanzelka; M. Chad Bolding; Scott M. Barrett; Jay Sullivan
2016-01-01
New or retrofitted wood-fired energy plants have increased demand for woody biomass in the stateof Virginia. Loblolly pine (Pinus taeda) commonly serves as a feedstock for these energy plants. Pulpwood conventionally requires a minimum diameter of 4 inches diameter at breast height (DBH) for merchantability, whereas a minimum merchantable diameter...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-25
... Diameter Line Pipe From Japan; Scheduling of a Full Five-Year Review Concerning the Antidumping Duty Order on Welded Large Diameter Line Pipe From Japan AGENCY: United States International Trade Commission... revocation of the antidumping duty order on welded large diameter line pipe from Japan would be likely to...
Height-diameter equations for thirteen midwestern bottomland hardwood species
Kenneth C. Colbert; David R. Larsen; James R. Lootens
2002-01-01
Height-diameter equations are often used to predict the mean total tree height for trees when only diameter at breast height (dbh) is measured. Measuring dbh is much easier and is subject to less measurement error than total tree height. However, predicted heights only reflect the average height for trees of a particular diameter. In this study, we present a set of...
Vincze, Boglárka; Gáspárdy, András; Kovács, Levente; Albert, Ervin; Kézér, Luca; Baska, Ferenc; Szenci, Ottó
2017-03-01
Transabdominal ultrasonography has been shown to be a useful and reliable method for assessing fetal well-being in horses and cattle. To test the applicability of fetal aortic diameter measurement in cattle, 44 late-term pregnant cows and heifers were examined 21 to 0 days prior to calving. Mean fetal aortic diameter was 2.07 ± 0.14 cm and mean fetal heart rate (FHR) was 109 ± 17 bpm. Three dead calves were dissected and their aortic diameter was measured in a water bath. The mean birth weight (n = 44) was 39.9 ± 5.8 kg. There was a significant negative correlation between FHR and fetal aortic diameter. However, although some studies have shown that fetal aortic diameter strongly correlates with birth weight in near-term horses and cattle, in this study there was no correlation between fetal aortic diameter and birth weight in Holstein-Friesian cows and heifers irrespective of whether the fetus was born alive or dead.
Relationship between the tensile strengths and diameters of human umbilical cords.
Fernando, D M G; Gamage, S M K; Ranmohottige, S; Weerakkody, I; Abeyruwan, H; Parakrama, H
2018-05-01
Mothers of alleged infanticides might claim that umbilical cord broke during precipitate delivery causing injuries detected on baby at autopsy. There is paucity of evidence regarding this possibility. The objective of the study was to determine relationship between tensile strength and diameter or weight per unit length of cord. Diameters and weights per unit length of fresh umbilical cords were determined. Tensile strengths were measured by Hounsfield Testing Machine. Relationship between tensile strength versus cord diameter and weight per unit length were analyzed. Of 122 cords, average tensile strength, diameter and weight per centimeter were 50.4 N, 7.73 mm and 6.87 g respectively. The tensile strengths were directly proportional to diameter. There was no association between tensile strength and weight per centimeter. Measurement of the diameter of cord is important during autopsy to predict tensile strength and thereby to presume whether cord could have broken by the weight of the baby. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Particle sizing by weighted measurements of scattered light
NASA Technical Reports Server (NTRS)
Buchele, Donald R.
1988-01-01
A description is given of a measurement method, applicable to a poly-dispersion of particles, in which the intensity of scattered light at any angle is weighted by a factor proportional to that angle. Determination is then made of four angles at which the weighted intensity is four fractions of the maximum intensity. These yield four characteristic diameters, i.e., the diameters of the volume/area mean (D sub 32 the Sauter mean) and the volume/diameter mean (D sub 31); the diameters at cumulative volume fractions of 0.5 (D sub v0.5 the volume median) and 0.75 (D sub v0.75). They also yield the volume dispersion of diameters. Mie scattering computations show that an average diameter less than three micrometers cannot be accurately measured. The results are relatively insensitive to extraneous background light and to the nature of the diameter distribution. Also described is an experimental method of verifying the conclusions by using two microscopic slides coated with polystyrene microspheres to simulate the particles and the background.
NASA Astrophysics Data System (ADS)
Miyagawa, Chihiro; Kobayashi, Takumi; Taishi, Toshinori; Hoshikawa, Keigo
2014-09-01
Based on the growth of 3-inch diameter c-axis sapphire using the vertical Bridgman (VB) technique, numerical simulations were made and used to guide the growth of a 6-inch diameter sapphire. A 2D model of the VB hot-zone was constructed, the seeding interface shape of the 3-inch diameter sapphire as revealed by green laser scattering was estimated numerically, and the temperature distributions of two VB hot-zone models designed for 6-inch diameter sapphire growth were numerically simulated to achieve the optimal growth of large crystals. The hot-zone model with one heater was selected and prepared, and 6-inch diameter c-axis sapphire boules were actually grown, as predicted by the numerical results.
Abdollahi, M R; Ravindran, V; Wester, T J; Ravindran, G; Thomas, D V
2013-06-01
1. The influence of pellet diameter and length on the quality of pellets and performance, nutrient utilisation and digestive tract development of broilers given wheat-based diets was examined from 10 to 42 d of age. The experimental design was a 2 × 2 factorial arrangement of treatments evaluating two pellet diameters (3 and 4.76 mm) and two pellet lengths (3 and 6 mm). From 0 to 9 d of age, all birds were offered a common starter diet pelleted with a 3-mm diameter die and 3-mm length. Broiler grower (d 10 to 21) and finisher (d 22 to 42) diets, based on wheat, were formulated and then subjected to the 4 different treatments. 2. In grower diets, increasing pellet diameter and pellet length reduced the gelatinised starch (GS) content of the diets. In finisher diets, GS content of 3-mm diameter pellets did not change with increasing pellet length but decreased in 4.76-mm diameter pellets. 3. In grower and finisher diets, increments in intact pellet weight, pellet durability index and pellet hardness with increasing pellet length were greater in 3-mm diameter pellets than those with 4.76-mm diameter. 4. Increasing pellet length from 3 to 6 mm increased apparent metabolisable energy values. Neither the interaction nor main effects were significant for the ileal digestibility of nitrogen and starch. 5. During the grower period (d 10 to 21), birds given pellets of 6-mm length had greater body-weight gain than those given 3-mm length pellets. Feeding 6-mm length pellets decreased feed per body-weight gain compared to 3-mm length pellets. During the finisher (d 22 to 42) and whole grow-out (d 10 to 42) periods, while different pellet lengths had no effect on feed per body-weight gain values at 3-mm pellet diameter, increasing the pellet length decreased feed per body-weight gain at 4.76-mm pellet diameter. 6. Increasing pellet diameter and pellet length reduced the relative length of duodenum. Birds given 3-mm diameter pellets had heavier proventriculus compared to those given 4.76-mm diameter pellets. 7. Overall, the data suggest that increasing the pellet length from 3 to 6 mm improved the body-weight gain and feed per body-weight gain during the grower period (d 10 to 21). While the positive effect on body-weight gain disappeared as the birds grew older, improvements in feed per body-weight gain were maintained over the finisher and whole grow-out periods only in 4.76-mm diameter pellets. Small diameter die holes and longer pellet lengths may be considered as potential manipulations to manufacture high-quality pellets under low conditioning temperatures.
Diameter Effect In Initiating Explosives, Numerical Simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lefrancois, A.; Benterou, J.; Roeske, F.
2006-02-10
The ability to safely machine small pieces of HE with the femtosecond laser allows diameter effect experiments to be performed in initiating explosives in order to study the failure diameter, the reduction of the detonation velocity and curvature versus the diameter. The reduced diameter configuration needs to be optimized, so that the detonation products of the first cylinder will not affect the measurement of the detonation velocity of the second cylinder with a streak camera. Different 2D axi-symmetrical configurations have been calculated to identify the best solution using the Ignition and Growth reactive flow model for LX16 Pellet with Ls-Dyna.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Florida Oranges and Tangelos Definitions § 51.1174 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Florida Oranges and Tangelos Definitions § 51.1174 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem...
NASA Astrophysics Data System (ADS)
Cui, Kehang; Kumamoto, Akihito; Xiang, Rong; An, Hua; Wang, Benjamin; Inoue, Taiki; Chiashi, Shohei; Ikuhara, Yuichi; Maruyama, Shigeo
2016-01-01
We synthesize vertically aligned single-walled carbon nanotubes (VA-SWNTs) with subnanometer diameters on quartz (and SiO2/Si) substrates by alcohol CVD using Cu-anchored Co catalysts. The uniform VA-SWNTs with a nanotube diameter of 1 nm are synthesized at a CVD temperature of 800 °C and have a thickness of several tens of μm. The diameter of SWNTs was reduced to 0.75 nm at 650 °C with the G/D ratio maintained above 24. Scanning transmission electron microscopy energy-dispersive X-ray spectroscopy (EDS-STEM) and high angle annular dark field (HAADF-STEM) imaging of the Co/Cu bimetallic catalyst system showed that Co catalysts were captured and anchored by adjacent Cu nanoparticles, and thus were prevented from coalescing into a larger size, which contributed to the small diameter of SWNTs. The correlation between the catalyst size and the SWNT diameter was experimentally clarified. The subnanometer-diameter and high-quality SWNTs are expected to pave the way to replace silicon for next-generation optoelectronic and photovoltaic devices.We synthesize vertically aligned single-walled carbon nanotubes (VA-SWNTs) with subnanometer diameters on quartz (and SiO2/Si) substrates by alcohol CVD using Cu-anchored Co catalysts. The uniform VA-SWNTs with a nanotube diameter of 1 nm are synthesized at a CVD temperature of 800 °C and have a thickness of several tens of μm. The diameter of SWNTs was reduced to 0.75 nm at 650 °C with the G/D ratio maintained above 24. Scanning transmission electron microscopy energy-dispersive X-ray spectroscopy (EDS-STEM) and high angle annular dark field (HAADF-STEM) imaging of the Co/Cu bimetallic catalyst system showed that Co catalysts were captured and anchored by adjacent Cu nanoparticles, and thus were prevented from coalescing into a larger size, which contributed to the small diameter of SWNTs. The correlation between the catalyst size and the SWNT diameter was experimentally clarified. The subnanometer-diameter and high-quality SWNTs are expected to pave the way to replace silicon for next-generation optoelectronic and photovoltaic devices. Electronic supplementary information (ESI) available: Comparison between the Co monometallic catalyst system and the Co/Mo bimetallic catalyst system, the effect of CVD temperature on the G/D ratio, the effect of ethanol partial pressure on the morphology, diameter and quality of SWNT films, and Raman spectra of the Si/SiO2 substrate. See DOI: 10.1039/c5nr06007a
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Florida Grapefruit Definitions § 51.783 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem to blossom end. ...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Oranges (Texas and States Other Than Florida, California, and Arizona) Definitions § 51.712 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Standards for Grades of Oranges (Texas and States Other Than Florida, California, and Arizona) Definitions § 51.712 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Florida Grapefruit Definitions § 51.783 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem to blossom end. ...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Florida Tangerines Definitions § 51.1836 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem to blossom end. ...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Florida Tangerines Definitions § 51.1836 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem to blossom end. ...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Oranges (Texas and States Other Than Florida, California, and Arizona) Definitions § 51.712 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem...
Predicting past and future diameter growth for trees in the northeastern United States
James A. Westfall
2006-01-01
Tree diameter growth models are widely used in forestry applications, often to predict tree size at a future point in time. Also, there are instances where projections of past diameters are needed. A relative diameter growth model was developed to allow prediction of both future and past growth rates. Coefficients were estimated for 15 species groups that cover most...
Growth of lodgepole pine stands and its relation to mountain pine beetle susceptibility
S.A. Mata; J.M. Schmid; W.K. Olsen
2003-01-01
Periodic diameter and basal area growth were determined for partially cut stands of lodgepole pine at five locations over approximately 10 year periods. After cutting, average diameters in the partially cut plots generally increased by 0.8 inches or more, while average diameter in the uncut controls increased by 0.6 inches or less. Diameter growth in the partially cut...
40 CFR Table 31 to Subpart G of... - Typical Number of Vacuum Breakers, NF6 and Roof Drains, a NF7
Code of Federal Regulations, 2012 CFR
2012-07-01
... data. b If the actual diameter is between the diameters listed, the closest diameter listed should be.... They are, however, used on double-deck floating roofs, and are typically left open. d For tanks more than 300 feet in diameter, actual tank data or the manufacturer's recommendations may be needed for the...
40 CFR Table 31 to Subpart G of... - Typical Number of Vacuum Breakers, NF6 and Roof Drains, a NF7
Code of Federal Regulations, 2014 CFR
2014-07-01
... data. b If the actual diameter is between the diameters listed, the closest diameter listed should be.... They are, however, used on double-deck floating roofs, and are typically left open. d For tanks more than 300 feet in diameter, actual tank data or the manufacturer's recommendations may be needed for the...
40 CFR Table 31 to Subpart G of... - Typical Number of Vacuum Breakers, NF6 and Roof Drains, a NF7
Code of Federal Regulations, 2010 CFR
2010-07-01
... data. b If the actual diameter is between the diameters listed, the closest diameter listed should be.... They are, however, used on double-deck floating roofs, and are typically left open. d For tanks more than 300 feet in diameter, actual tank data or the manufacturer's recommendations may be needed for the...
40 CFR Table 31 to Subpart G of... - Typical Number of Vacuum Breakers, NF6 and Roof Drains, a NF7
Code of Federal Regulations, 2011 CFR
2011-07-01
... data. b If the actual diameter is between the diameters listed, the closest diameter listed should be.... They are, however, used on double-deck floating roofs, and are typically left open. d For tanks more than 300 feet in diameter, actual tank data or the manufacturer's recommendations may be needed for the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-14
...-foot-long, 15.5- foot diameter concrete-lined low-pressure tunnel; (4) a 5,870-foot- long, 15.5-foot-diameter concrete-lined pressure shaft; (5) a 1,815- foot-long, 18.6-foot-diameter concrete-lined tailrace... storage capacity of 8,235-acre-foot; (3) a 1,190-foot-long, 15.5-foot-diameter concrete-lined low-pressure...
Variations in diameter measurements of Robusta Eucalyptus due to swelling and shrinking of bark
Robert E. Burgan
1971-01-01
Trunk diameters of Eucalyptus robusta trees shrink and swell as bark moisture content changes. Diameter variations from this cause as measured on six trees with a dial-gage dendrometer were less than 1 percent of trunk diameter. To compare this variation with the variation in d.b.h. measurements that can result from personal techiques of using a...
Effects of pruning height on the diameter growth of yellow birch
Dale S. Solomon; Barton M. Blum
1977-01-01
The diameter growth rate of pruned trees increased the second year after pruning, whereas the diameter growth of unpruned trees was not as fast during the second year. Diameter growth rate was positively correlated with the height to which all branches were pruned. After the pruning shock of the first year, trees pruned to 50 percent of their height showed the greatest...
A diameter increment model for Red Fir in California and Southern Oregon
K. Leroy Dolph
1992-01-01
Periodic (10-year) diameter increment of individual red fir trees in Califomia and southern Oregon can be predicted from initial diameter and crown ratio of each tree, site index, percent slope, and aspect of the site. The model actually predicts the natural logarithm ofthe change in squared diameter inside bark between the startand the end of a 10-year growth period....
Largest-Crown- Width Prediction Models for 53 Species in the Western United States
William A. Bechtold
2004-01-01
The mean crown diameters of stand-grown trees 5.0-in. dbh and larger were modeled as a function of stem diameter, live-crown ratio, stand-level basal area, latitude, longitude, elevation, and Hopkins bioclimatic index for 53 tree species in the western United States. Stem diameter was statistically significant in all models, and a quadratic term for stem diameter was...
Pajević, Tina; Glišić, Branislav
2017-05-01
Anthropological studies have reported that tooth size decreases in the context of diet changes. Some investigations have found a reverse trend in tooth size from the prehistoric to the modern times. The aims of this study were to analyze tooth size in skeletal samples from Mesolithic-Neolithic Age, Bronze Age, and Roman to Medieval times to determine sex differences and establish a temporal trend in tooth size in the aforementioned periods. Well-preserved permanent teeth were included in the investigation. The mesiodistal (MD) diameter of all teeth and buccolingual (BL) diameter of the molars were measured. Effects of sex and site were tested by one-way ANOVA, and the combined effect of these factors was analyzed by UNIANOVA. Sexual dimorphism was present in the BL diameters of all molars and MD diameters of the upper first and the lower third molar. The lower canine was the most dimorphic tooth in the anterior region. The MD diameter of most teeth showed no significant difference between the groups, (sample from: Mesolithic-Neolithic Age-group 1; Bronze Age-group 2; Roman times-group 3; Medieval times-group 4), whereas the BL diameters of the upper second and the lower first molar were the largest in the first group. Multiple comparisons revealed a decrease in the BL diameter of the upper second and the lower first molar from the first to the later groups. Lower canine MD diameter exhibited an increase in the fourth group compared to the second group. On the basis of the MD diameter, a temporal trend could not be observed for most of the teeth. The lower canine exhibited an increase in the MD diameter from the prehistoric to the Medieval times. Changes of BL diameter were more homogeneous, suggesting that the temporal trend of molar size decreased from the Mesolithic-Neolithic to Medieval times in Serbia. Copyright © 2017. Published by Elsevier Ltd.
Unlu, Murat; Orguc, Sebnem; Serter, Selim; Pekindil, Gokhan; Pabuscu, Yuksel
2007-01-01
To investigate the anatomic and hemodynamic properties of testicular venous drainage and its effects on varicocele formation and reflux using color Doppler ultrasound (US) with emphasis on renal vein entrapment syndrome. Upper abdominal and scrotal US examinations of 35 varicocele patients and 35 healthy male subjects were performed in the supine position during rest, during a Valsalva maneuver and in the erect position. The aortomesenteric angle and distance (AMA and AMD, respectively), peak mean velocities (PVs) and diameters of different segments of renal veins, testicular vein diameters and duration of flow inversion were measured. In the varicocele group, the lateral segment of the left renal vein (LRV) had a larger diameter and slower PV, and the medial segment of the LRV had a smaller diameter and faster PV. The diameter of the dominant draining vein correlated with the PV of the medial and lateral segments of the LRV, whereas there was no correlation between the diameter of the dominant draining vein and the diameters of the right renal vein (RRV) and the lateral segment of the LRV or the PV of the RRV. The duration of flow inversion correlated with the diameter and PV of the medial segment of the LRV. No correlation between the diameters and PVs of the RRV and the lateral segment of the LRV was detected. The decreases in the AMA, AMD, diameter of the medial segment of the LRV and PV of the lateral segment of the LRV, and the increases in the PV of the medial segment of the LRV and the diameter of the lateral segment of the LRV in varicocele patients in all positions suggest the entrapment or impingement of the left renal vein between the aorta and the superior mesenteric artery. This has been defined as the "nutcracker phenomenon", which is known to affect varicocele formation.
Solans Pérez de Larraya, Ana M; Ortega Molina, José M; Fernández, José Uberos; Escudero Gómez, Júlia; Salgado Miranda, Andrés D; Chaves Samaniego, Maria J; García Serrano, José L
2018-03-01
To analyse the speed of temporal retinal vascularisation in preterm infants included in the screening programme for retinopathy of prematurity. A total of 185 premature infants were studied retrospectively between 2000 and 2017 in San Cecilio University Hospital of Granada, Spain. The method of binocular indirect ophthalmoscopy with indentation was used for the examination. The horizontal disc diameter was used as a unit of length. Speed of temporal retinal vascularisation (disc diameter/week) was calculated as the ratio between the extent of temporal retinal vascularisation (disc diameter) and the time in weeks. The weekly temporal retinal vascularisation (0-1.25 disc diameter/week, confidence interval) was significantly higher in no retinopathy of prematurity (0.73 ± 0.22 disc diameter/week) than in stage 1 retinopathy of prematurity (0.58 ± 0.22 disc diameter/week). It was also higher in stage 1 than in stages 2 (0.46 ± 0.14 disc diameter/week) and 3 of retinopathy of prematurity (0.36 ± 0.18 disc diameter/week). The rate of temporal retinal vascularisation (disc diameter/week) decreases when retinopathy of prematurity stage increases. The area under the receiver operating characteristic curve was 0.85 (95% confidence interval: 0.79-0.91) for retinopathy of prematurity requiring treatment versus not requiring treatment. The best discriminative cut-off point was a speed of retinal vascularisation <0.5 disc diameter/week, with a sensitivity and a specificity of 84.8% and 77%, respectively. The rate of temporal retinal vascularisation is a quantifiable observation that can help to alert a clinician that treatment of retinopathy of prematurity may be required. However, before becoming a new standard of care for treatment, it requires careful documentation, with agreement between several ophthalmologists.
Morphology-related limitations of EVAR applicability in the treatment of AAA in West-Central Poland.
Dzieciuchowicz, Łukasz; Tomczak, Jolanta; Strauss, Ewa; Oszkinis, Grzegorz
2018-05-14
To analyze the current applicability of endovascular aneurysm repair (EVAR) in patients with an infrarenal abdominal aortic aneurysm (AAAs) with indication for elective treatment in West-Central Poland. Computed tomography angiograms of 100 consecutive patients with infrarenal AAA deemed to require treatment were analyzed with an OsiriX DICOM viewer in 3D-MPR mode. Proximal neck diameter, length, angulation, shape, the presence of thrombus and calcification, distal neck diameter, and morphology of the iliac arteries were determined. Three sets of morphological criteria were established. The optimal criteria consisted of a non-conical proximal neck without moderate or severe calcification or thrombus, with a diameter of 18-28 mm, length of ≥15 mm, and β angulation of <60%; a distal neck with a diameter of ≥20 mm; a landing zone in the common iliac arteries with a length of ≥ 10 mm and diameter of ≤ 20 mm; and external iliac arteries with diameters of ≥7 mm. The suboptimal criteria included proximal neck diameters of 18-32 mm, neck lengths ≥10 mm, infrarenal neck angulations of up to 75˚, and common iliac artery diameters of up to 25 mm. Finally, the extended suboptimal criteria included proximal neck diameters of 16-34 mm and infrarenal neck angulations ≤90˚, without limits in the maximal diameter of the common iliac arteries. The median maximum aneurysm diameter was 61 mm. The optimal, suboptimal, and extended suboptimal criteria were met by 23%, 32%, and 53% of patients, respectively. The most common deviations were wide, conical, and angulated proximal necks and aneurysmal iliac arteries. The majority of patients with AAA deemed to be candidates for elective repair do not meet the most favorable criteria for EVAR. Availability of better endovascular solutions for conical, angulated, and wide necks and aneurysmal iliac arteries would likely expand EVAR applicability. Open repair remains a valid option. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamoureux, R; Sinclair, L; Mench, A
Purpose: To introduce and investigate effective diameter ratios as a new patient metric for use in computed tomography protocol selection as a supplement to patient-specific size parameter data. Methods: The metrics of outer effective diameter and inner effective diameter were measured for 7 post-mortem subjects scanned with a standardized chest/abdomen/pelvis (CAP) protocol on a 320-slice MDCT scanner. The outer effective diameter was calculated by obtaining the anterior/posterior and lateral dimensions of the imaged anatomy at the middle of the scan range using Effective Diameter= SQRT(AP height*Lat Width). The inner effective diameter was calculated with the same equation using the APmore » and Lat dimensions of the anatomy excluding the adipose tissue. The ratio of outer to inner effective diameter was calculated for each subject. A relationship to BMI, weight, and CTDI conversion coefficients was investigated. Results: For the largest subject with BMI of 43.85 kg/m2 and weight of 255 lbs the diameter ratio was calculated as 1.33. For the second largest subject with BMI of 33.5 kg/m2 and weight of 192.4 lbs the diameter ratio was measured as 1.43, indicating a larger percentage of adipose tissue in the second largest subject’s anatomical composition. For the smallest subject at BMI of 17.4 kg/m2 and weight of 86 lbs a similar tissue composition was indicated as a subject with BMI of 24.2 kg/m2 and weight of 136 lbs as they had the same diameter ratios of 1.11. Conclusion: The diameter ratio proves to contain information about anatomical composition that the BMI and weight alone do not. The utility of this metric is still being examined but could prove useful for determining MDCT techniques and for giving a more in depth detail of the composition of a patient’s body habitus.« less
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades for Sweet Cherries 1 Definitions § 51.2656 Diameter. Diameter means the greatest dimension measured at right angles to a line from the stem to the blossom end of the cherry. ...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Persian (Tahiti) Limes Definitions § 51.1016 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem to blossom end of the...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades for Sweet Cherries 1 Definitions § 51.2656 Diameter. Diameter means the greatest dimension measured at right angles to a line from the stem to the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Standards for Grades for Sweet Cherries 1 Definitions § 51.2656 Diameter. Diameter means the greatest dimension measured at right angles to a line from the stem to the blossom end of the cherry. ...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades for Sweet Cherries 1 Definitions § 51.2656 Diameter. Diameter means the greatest dimension measured at right angles to a line from the stem to the...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades for Sweet Cherries 1 Definitions § 51.2656 Diameter. Diameter means the greatest dimension measured at right angles to a line from the stem to the blossom end of the cherry. ...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Persian (Tahiti) Limes Definitions § 51.1016 Diameter. Diameter means the greatest dimension measured at right angles to a line from stem to blossom end of the...
Termeie, Deborah; Klokkevold, Perry R; Caputo, Angelo A
2015-10-01
The long-term clinical success of a dental implant is dependent upon maintaining sufficient osseointegration to resist forces of occlusion. The purpose of this study was to investigate the effect of implant diameter on stress distribution around screw-type dental implants in mandibular first molar sites using photoelastic models. The design included models with different buccal-lingual dimension. Twelve composite photoelastic models were assembled using 2 different resins to simulate trabecular and cortical bone. Half of the models were fabricated with average dimensions for ridge width and the other half with narrower buccal-lingual dimensions. One internal connection implant (13 mm length) with either a standard (4 mm), wide (5 mm), or narrow (3.3 mm) diameter was embedded in the first molar position of each photoelastic model. Half the implants were tapered and the other half were straight. Full gold crowns in the shape of a mandibular first molar were fabricated and attached to the implants. Vertical and angled loads of 15 and 30 pounds were applied to specific points on the crown. Wide-diameter implants produced the least stress in all ridges while narrow-diameter implants generated the highest stress, especially in narrow ridges. It may be that the volume and quality of bone surrounding implants influences stress distribution with a greater ratio of cortical to trabecular bone, thus providing better support. Models with wide-diameter implants loaded axially had a more symmetrical stress distribution compared to standard and narrow diameter implants. A more asymmetrical stress pattern developed along the entire implant length with angled loads. Implant diameter and ridge width had considerable influence on stress distribution. Narrow-diameter implants produced more stress than wide diameter implants in all conditions tested.
Climate-diameter growth relationships of black spruce and jack pine trees in boreal Ontario, Canada.
Subedi, Nirmal; Sharma, Mahadev
2013-02-01
To predict the long-term effects of climate change - global warming and changes in precipitation - on the diameter (radial) growth of jack pine (Pinus banksiana Lamb.) and black spruce (Picea mariana [Mill.] B.S.P.) trees in boreal Ontario, we modified an existing diameter growth model to include climate variables. Diameter chronologies of 927 jack pine and 1173 black spruce trees, growing in the area from 47°N to 50°N and 80°W to 92°W, were used to develop diameter growth models in a nonlinear mixed-effects approach. Our results showed that the variables long-term average of mean growing season temperature, precipitation during wettest quarter, and total precipitation during growing season were significant (alpha = 0.05) in explaining variation in diameter growth of the sample trees. Model results indicated that higher temperatures during the growing season would increase the diameter growth of jack pine trees, but decrease that of black spruce trees. More precipitation during the wettest quarter would favor the diameter growth of both species. On the other hand, a wetter growing season, which may decrease radiation inputs, increase nutrient leaching, and reduce the decomposition rate, would reduce the diameter growth of both species. Moreover, our results indicated that future (2041-2070) diameter growth rate may differ from current (1971-2000) growth rates for both species, with conditions being more favorable for jack pine than black spruce trees. Expected future changes in the growth rate of boreal trees need to be considered in forest management decisions. We recommend that knowledge of climate-growth relationships, as represented by models, be combined with learning from adaptive management to reduce the risks and uncertainties associated with forest management decisions. © 2012 Blackwell Publishing Ltd.
Interaction of Highly Underexpanded Jets with Simulated Lunar Surfaces
NASA Technical Reports Server (NTRS)
Stitt, Leonard E.
1961-01-01
Pressure distributions and erosion patterns on simulated lunar surfaces (hard and soft) and interference effects between the surface and two representative lunar vehicles (cylindrical and spherical) were obtained with cold-air jets at various descent heights and nozzle total-pressure ratios up to 288,000. Surface pressure distributions were dependent on both nozzle area ratio and, nozzle contour. Peak pressures obtained with a sonic nozzle agreed closely with those predicted theoretically for a near-sonic jet expanding into a vacuum. Short bell-shaped nozzles gave annular pressure distributions; the low center pressure resulted from the coalescence of shocks that originated within the nozzle. The high surface pressures were contained within a circle whose diameter was about 16 throat diameters, regardless of nozzle area ratio or contour. The peak pressure increased rapidly as the vehicle approached the surface; for example, at a descent height of 40 throat diameters the peak pressure was 0.4 percent of the chamber pressure, but increased to 6 percent at 13 throat diameters. The exhaust jet eroded a circular concave hole in white sand at descent heights from about 200 to 600 throat diameters. The hole diameter was about 225 throat diameters, while the depth was approximately 60 throat diameters. The sand particles, which formed a conical sheet at a semivertex angle of 50 deg, appeared to follow a ballistic trajectory and at no time struck the vehicle. An increase in pressure was measured on the base of the cylindrical lunar vehicle when it approached to within 14 throat diameters of the hard, flat surface. No interference effects were noted between the spherical model and the surface to descent heights as low as 8 throat diameters.
Experimental investigation of two-phase flow patterns in minichannels at horizontal orientation
NASA Astrophysics Data System (ADS)
Saljoshi, P. S.; Autee, A. T.
2017-09-01
Two-phase flow is the simplest case of multiphase flow in which two phases are present for a pure component. The mini channel is considered as diameter below 3.0-0.2 mm and conventional channel is considered diameter above 3.0 mm. An experiment was conducted to study the adiabatic two-phase flow patterns in the circular test section with inner diameter of 1.1, 1.63, 2.0, 2.43 and 3.0 mm for horizontal orientation using air and water as a fluid. Different types of flow patterns found in the experiment. The parameters that affect most of these patterns and their transitions are channel size, phase superficial velocities (air and liquid) and surface tension. The superficial velocity of liquid and gas ranges from 0.01 to 66.70 and 0.01 to 3 m/s respectively. Two-phase flow pattern photos were recorded using a high speed CMOS camera. In this experiment different flow patterns were identified for different tube diameters that confirm the diameter effect on flow patterns in two-phase flows. Stratified flow was not observed for tube diameters less than 3.0 mm. Similarly, wavy-annular flow pattern was not observed in 1.6 and 1.0 mm diameter tubes due to the surface-tension effect and decrease in tube diameter. Buoyancy effects were clearly visible in 2.43 and 3.0 mm diameter tubes flow pattern. It has also observed that as the test-section diameter decreases the transition lines shift towards the higher gas and liquid velocity. However, the result of flow pattern lines in the present study has good agreement with the some of the existing flow patterns maps.
Leiter, Jeff; Elkurbo, Mohamed; McRae, Sheila; Chiu, James; Froese, Warren; MacDonald, Peter
2017-01-01
Large variation in tendon size between individuals makes hamstring graft diameter for anterior cruciate ligament (ACL) reconstruction unpredictable. Inadequate graft diameter may necessitate an alternative source of tissue requiring pre-operative planning. The purpose of this study was to determine whether magnetic resonance image (MRI) measurements and clinical anthropometric data are predictive of hamstring tendon graft diameter. Data from 109 patients having ACL reconstruction with semitendinosus-gracilis (STGT) autograft were retrospectively evaluated. Cross-sectional area (CSA) of the gracilis tendon (GT) and semitendinosus tendon (ST) were determined from pre-operative MRI scans. Variables included pre-operative height, weight, body mass index (BMI), age and gender; and intra-operative graft diameter. Correlations between anthropometric variables, hamstring tendons CSA and intra-operative graft diameter were calculated. Multiple stepwise regression was performed to assess the predictive value of these variables to graft diameter. Sensitivity and specificity were calculated to evaluate the utility of MRI CSA measurements in accurately identifying inadequate graft diameter (<8 mm). All anthropometric variables were positively correlated with intraoperative graft diameter (p < 0.01). Semitendinosus-gracilis tendon CSA (p < 0.001) and STGT CSA and weight (p < 0.001) were significantly predictive models of graft diameter. Sensitivity and specificity were 79 and 74 %, respectively. The strongest indicators of a four-stranded STGT graft for primary ACL reconstruction were STGT CSA on MRI plus weight. Measurement of graft diameter can be performed pre-operatively via MRI to identify tendons that may be of inadequate size for ACL reconstruction. This can assist with surgical planning to determine the most appropriate graft choice. III.
Liao, Ying-Chieh; Liao, Jo-Nan; Lo, Li-Wei; Lin, Yenn-Jiang; Chang, Shih-Lin; Hu, Yu-Feng; Chao, Tze-Fan; Chung, Fa-Po; Tuan, Ta-Chuan; Te, Abigail Louise D; Walia, Rohit; Yamada, Shinya; Lin, Chung-Hsing; Lin, Chin-Yu; Chang, Yao-Ting; Allamsetty, Suresh; Yu, Wen-Chung; Huang, Jing-Long; Wu, Tsu-Juey; Chen, Shih-Ann
2017-01-01
Although rare, some paroxysmal atrial fibrillations (AF) still progress despite radiofrequency (RF) ablation. In the study, we evaluated the long-term efficacy of RF ablation and the predictors of AF progression. A total of 589 paroxysmal AF patients (404 men and 185 women; aged 54 ± 12 years) who received 3-dimensional mapping and ablation were enrolled. Their clinical parameters and electrophysiological characteristics were collected. They were divided into Group 1 (N = 13, with AF progression) and Group 2 (N = 576, no AF progression). AF progression was defined as recurrence of persistent AF. Group 1 patients had larger left atrial (LA) diameter, larger left ventricle (LV) end-systolic and end-diastolic diameters, poorer LV systolic function, and more amiodarone use at baseline. After 1.2 ± 0.5 procedures, 123 (21%) patients experienced recurrence during 56 ± 29 months' follow-up. In the multivariate analysis, LA diameter (P = 0.018, HR = 1.12, 95% CI = 1.02-1.24) and LV end-systolic diameter (P = 0.005, HR = 1.10, 95% CI = 1.03-1.17) independently predicted AF progression. LA diameter >43 mm and LV end-systolic diameter >31 mm were the best cut-off values for predicting AF progression by ROC analysis. AF progression rate achieved 19% if they had both larger LA diameter (>43 mm) and LV end-systolic diameter (>31 mm). RF ablation prevents the progression of paroxysmal AF effectively, except in patients with increased LA diameter and LV end-systolic diameter on echocardiogram, suggesting more aggressive rhythm control therapies should be considered in these patients. © 2016 Wiley Periodicals, Inc.
Inferring diameters of spheres and cylinders using interstitial water.
Herrera, Sheryl L; Mercredi, Morgan E; Buist, Richard; Martin, Melanie
2018-06-04
Most early methods to infer axon diameter distributions using magnetic resonance imaging (MRI) used single diffusion encoding sequences such as pulsed gradient spin echo (SE) and are thus sensitive to axons of diameters > 5 μm. We previously simulated oscillating gradient (OG) SE sequences for diffusion spectroscopy to study smaller axons including the majority constituting cortical connections. That study suggested the model of constant extra-axonal diffusion breaks down at OG accessible frequencies. In this study we present data from phantoms to test a time-varying interstitial apparent diffusion coefficient. Diffusion spectra were measured in four samples from water packed around beads of diameters 3, 6 and 10 μm; and 151 μm diameter tubes. Surface-to-volume ratios, and diameters were inferred. The bead pore radii estimates were 0.60±0.08 μm, 0.54±0.06 μm and 1.0±0.1 μm corresponding to bead diameters ranging from 2.9±0.4 μm to 5.3±0.7 μm, 2.6±0.3 μm to 4.8±0.6 μm, and 4.9±0.7 μm to 9±1 μm. The tube surface-to-volume ratio estimate was 0.06±0.02 μm -1 corresponding to a tube diameter of 180±70 μm. Interstitial models with OG inferred 3-10 μm bead diameters from 0.54±0.06 μm to 1.0±0.1 μm pore radii and 151 μm tube diameters from 0.06±0.02 μm -1 surface-to-volume ratios.
Wilhelm, Konrad; Miernik, Arkadiusz; Hein, Simon; Schlager, Daniel; Adams, Fabian; Benndorf, Matthias; Fritz, Benjamin; Langer, Mathias; Hesse, Albrecht; Schoenthaler, Martin; Neubauer, Jakob
2018-06-02
To validate AutoMated UroLithiasis Evaluation Tool (AMULET) software for kidney stone volumetry and compare its performance to standard clinical practice. Maximum diameter and volume of 96 urinary stones were measured as reference standard by three independent urologists. The same stones were positioned in an anthropomorphic phantom and CT scans acquired in standard settings. Three independent radiologists blinded to the reference values took manual measurements of the maximum diameter and automatic measurements of maximum diameter and volume. An "expected volume" was calculated based on manual diameter measurements using the formula: V=4/3 πr³. 96 stones were analyzed in the study. We had initially aimed to assess 100. Nine were replaced during data acquisition due of crumbling and 4 had to be excluded because the automated measurement did not work. Mean reference maximum diameter was 13.3 mm (5.2-32.1 mm). Correlation coefficients among all measured outcomes were compared. The correlation between the manual and automatic diameter measurements to the reference was 0.98 and 0.91, respectively (p<0.001). Mean reference volume was 1200 mm³ (10-9000 mm³). The correlation between the "expected volume" and automatically measured volume to the reference was 0.95 and 0.99, respectively (p<0.001). Patients' kidney stone burden is usually assessed according to maximum diameter. However, as most stones are not spherical, this entails a potential bias. Automated stone volumetry is possible and significantly more accurate than diameter-based volumetric calculations. To avoid bias in clinical trials, size should be measured as volume. However, automated diameter measurements are not as accurate as manual measurements.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumueller, Stephan, E-mail: Stephan.Baumueller@usz.ch; Nguyen, Thi Dan Linh, E-mail: ThiDanLinh.Nguyen@usz.ch; Goetti, Robert Paul, E-mail: RobertPaul.Goetti@usz.ch
2011-12-15
Purpose: To assess the accuracy of maximum diameter measurements of aortic aneurysms after endovascular aneurysm repair (EVAR) on axial computed tomographic (CT) images in comparison to maximum diameter measurements perpendicular to the intravascular centerline for follow-up by using three-dimensional (3D) volume measurements as the reference standard. Materials and Methods: Forty-nine consecutive patients (73 {+-} 7.5 years, range 51-88 years), who underwent EVAR of an infrarenal aortic aneurysm were retrospectively included. Two blinded readers twice independently measured the maximum aneurysm diameter on axial CT images performed at discharge, and at 1 and 2 years after intervention. The maximum diameter perpendicular tomore » the centerline was automatically measured. Volumes of the aortic aneurysms were calculated by dedicated semiautomated 3D segmentation software (3surgery, 3mensio, the Netherlands). Changes in diameter of 0.5 cm and in volume of 10% were considered clinically significant. Intra- and interobserver agreements were calculated by intraclass correlations (ICC) in a random effects analysis of variance. The two unidimensional measurement methods were correlated to the reference standard. Results: Intra- and interobserver agreements for maximum aneurysm diameter measurements were excellent (ICC = 0.98 and ICC = 0.96, respectively). There was an excellent correlation between maximum aneurysm diameters measured on axial CT images and 3D volume measurements (r = 0.93, P < 0.001) as well as between maximum diameter measurements perpendicular to the centerline and 3D volume measurements (r = 0.93, P < 0.001). Conclusion: Measurements of maximum aneurysm diameters on axial CT images are an accurate, reliable, and robust method for follow-up after EVAR and can be used in daily routine.« less
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Pears for Canning Definitions § 51.1359 Diameter. Diameter means the greatest dimension of the pear taken at right angles to a line running from the stem to...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Pears for Canning Definitions § 51.1359 Diameter. Diameter means the greatest dimension of the pear taken at right angles to a line running from the stem to...
Applegate, Raymond A.; Donnelly, William J.; Marsack, Jason D.; Koenig, Darren E.; Pesudovs, Konrad
2007-01-01
We report root-mean-square (RMS) wavefront error (WFE) for individual aberrations and cumulative high-order (HO) RMS WFE for the normal human eye as a function of age by decade and pupil diameter in 1 mm steps from 3 to 7 mm and determine the relationship among HO RMS WFE, mean age for each decade of life, and luminance for physiologic pupil diameters. Subjects included 146 healthy individuals from 20 to 80 years of age. Ocular aberration was measured on the preferred eye of each subject (for a total of 146 eyes through dilated pupils; computed for 3, 4, 5, 6, and 7 mm pupils; and described with a tenth-radial-order normalized Zernike expansion. We found that HO RMS WFE increases faster with increasing pupil diameter for any given age and pupil diameter than it does with increasing age alone. A planar function accounts for 99% of the variance in the 3-D space defined by mean log HO RMS WFE, mean age for each decade of life, and pupil diameter. When physiologic pupil diameters are used to estimate HO RMS WFE as a function of luminance and age, at low luminance (9 cd/m2) HO RMS WFE decreases with increasing age. This normative data set details (1) the 3-D relationship between HO RMS WFE and age for fixed pupil diameters and (2) the 3-D relationship among HO RMS WFE, age, and luminance for physiologic pupil diameters. PMID:17301847
Michael T. Thompson
2015-01-01
The Interior West Forest Inventory and Analysis Unit (IWFIA) will soon transition from a regional system to a national FIA system for compiling estimates of forest growth, removals, and mortality. The national system requires regional diameter-growth models to estimate diameters on trees in situations where the initial or terminal diameter is not known at the beginning...
Use of the Weibull function to predict future diameter distributions from current plot data
Quang V. Cao
2012-01-01
The Weibull function has been widely used to characterize diameter distributions in forest stands. The future diameter distribution of a forest stand can be predicted by use of a Weibull probability density function from current inventory data for that stand. The parameter recovery approach has been used to ârecoverâ the Weibull parameters from diameter moments or...
NASA Astrophysics Data System (ADS)
Xu, Q.; Hou, Z.; Maltamo, M.; Tokola, T.
2015-12-01
Diameter distributions of trees are important indicators of current forest stand structure and future dynamics. A new method was proposed in the study to combine the diameter distributions derived from the area-based approach (ABA) and the diameter distribution derived from the individual tree detection (ITD) in order to obtain more accurate forest stand attributes. Since dominant trees can be reliably detected and measured by the Lidar data via the ITD, the focus of the study is to retrieve the suppressed trees (trees that were missed by the ITD) from the ABA. Replacement and histogram matching were respectively employed at the plot level to retrieve the suppressed trees. Cut point was detected from the ITD-derived diameter distribution for each sample plot to distinguish dominant trees from the suppressed trees. The results showed that calibrated diameter distributions were more accurate in terms of error index and the entire growing stock estimates. Compared with the best performer between the ABA and the ITD, calibrated diameter distributions decreased the relative RMSE of the estimated entire growing stock, saw log and pulpwood fractions by 2.81%, 3.05% and 7.73% points respectively. Calibration improved the estimation of pulpwood fraction significantly, resulting in a negligible bias of the estimated entire growing stock.
NASA Astrophysics Data System (ADS)
Rhaodah Andsaler, Adiba; Khalid, Amir; Sharifhatul Adila Abdullah, Nor; Sapit, Azwan; Jaat, Norrizam
2017-04-01
Mixture formation of the ignition process is a key element in the diesel combustion as it influences the combustion process and exhaust emission. Aim of this study is to elucidate the effects of nozzle diameter, injection pressure and ambient temperature to the formation of spray. This study investigated diesel formation spray using Computational Fluid Dynamics. Multiphase volume of fluid (VOF) behaviour in the chamber are determined by means of transient simulation, Eulerian of two phases is used for implementation of mixing fuel and air. The detail behaviour of spray droplet diameter, spray penetration and spray breakup length was visualised using the ANSYS 16.1. This simulation was done in different nozzle diameter 0.12 mm and 0.2 mm performed at the ambient temperature 500 K and 700 K with different injection pressure 40 MPa, 70 MPa and 140 MPa. Results show that high pressure influence droplet diameter become smaller and the penetration length longer with the high injection pressure apply. Smaller nozzle diameter gives a shorter length of the breakup. It is necessary for nozzle diameter and ambient temperature condition to improve the formation of spray. High injection pressure is most effective in improvement of formation spray under higher ambient temperature and smaller nozzle diameter.
Positive contact, self retaining bearing seals
Johnson, Bruce H.; Larsen, Lawrence E.; Welch, Edmund F.
1992-05-05
An ultra-low friction bearing including an inner race, an outer race, bearing elements engaged between the inner and outer races and a seal between the inner and outer races is disclosed. The seal includes first and second sealing washers. The first washer has an outer diameter greater than an inner diameter of the outer race and an inner diameter greater than the outer diameter of the inner race. The second washer has an inner diameter less than the outer diameter of the inner race and an outer diameter less than the inner diameter of the outer race. The first washer slidably engages the outer race, the second washer slidably engages the inner race and the washers overlap and slidably engage one another. One of the washers snap fits into its respective inner or outer race while the other washer engages a stepped surface of the other of the inner and outer races. The grooved and stepped surface are offset from one another in a longitudinal direction of the races such that the washers are conically loaded thus providing a seal between the inner and outer races sufficient to prevent lubricant and contaminating particles from passing therethrough. The washers are made from a non-metallic semi-flexible low-modulus material.
Chen, Xin; Hu, Rui; Bai, Fan
2017-01-01
The influences of diameter and length of the Fe−N4-patched carbon nanotubes (Fe−N4/CNTs) on oxygen reduction reaction (ORR) activity were investigated by density functional theory method using the BLYP/DZP basis set. The results indicate that the stability of the Fe−N4 catalytic site in Fe−N4/CNTs will be enhanced with a larger tube diameter, but reduced with shorter tube length. A tube with too small a diameter makes a Fe−N4 site unstable in acid medium since Fe−N and C−N bonds must be significantly bent at smaller diameters due to hoop strain. The adsorption energy of the ORR intermediates, especially of the OH group, becomes weaker with the increase of the tube diameter. The OH adsorption energy of Fe−N4/CNT with the largest tube diameter is close to that on Pt(111) surface, indicating that its catalytic property is similar to Pt. Electronic structure analysis shows that the OH adsorption energy is mainly controlled by the energy levels of Fe 3d orbital. The calculation results uncover that Fe−N4/CNTs with larger tube diameters and shorter lengths will exhibit better ORR activity and stability. PMID:28772903
NASA Technical Reports Server (NTRS)
Grey, Ralph E; Brightwell, Virginia L; Barson, Zelmar; NACA
1950-01-01
An altitude-chamber investigation of British Rolls-Royce Nene II turbojet engine was conducted over range of altitudes from sea level to 65,000 feet and ram pressure ratios from 1.10 to 3.50, using an 18.00-inch-diameter jet nozzle. The 18.00-inch-diameter jet nozzle gave slightly lower values of net-thrust specific fuel consumption than either the 18.41- or the standard 18.75-inch-diameter jet nozzles at high flight speeds. At low flight speeds, the 18.41-inch-diameter jet nozzle gave the lowest value of net-thrust specific fuel consumption.
Design of Tools for Press-countersinking or Dimpling 0.040-inch-thick-24S-T Sheet
NASA Technical Reports Server (NTRS)
Templin, R L; Fogwell, J W
1942-01-01
A set of dimpling tools was designed for 0.040-inch 24S-T sheet and flush-type rivets 1/8 inch in diameter with 100 degree countersunk heads. The dimples produced under different conditions of pressure, sheet thickness, and drill diameter are presented as cross-sectional photographs magnified 20 times. The most satisfactory values for the dimpling tools were found to be: maximum punch diameter, 0.231 inch; maximum die diameter, 0.223 inch; maximum mandrel diameter, 0.128 inch; dimple angle, 100 degree; punch springback angle, 1 1/2 degree; and die springback angle, 2 degree.
NASA Astrophysics Data System (ADS)
Zemenkova, M. Y.; Shabarov, A.; Shatalov, A.; Puldas, L.
2018-05-01
The problem of the pore space description and the calculation of relative phase permeabilities (RPP) for two-phase filtration is considered. A technique for constructing a pore-network structure for constant and variable channel diameters is proposed. A description of the design model of RPP based on the capillary pressure curves is presented taking into account the variability of diameters along the length of pore channels. By the example of the calculation analysis for the core samples of the Urnenskoye and Verkhnechonskoye deposits, the possibilities of calculating RPP are shown when using the stochastic distribution of pores by diameters and medium-flow diameters.
Controlled growth of well-aligned carbon nanotubes with large diameters
NASA Astrophysics Data System (ADS)
Wang, Xianbao; Liu, Yunqi; Zhu, Daoben
2001-06-01
Well-aligned carbon nanotubes (CNTs) with large diameters (25-200 nm) were synthesized by pyrolysis of iron(II) phthalocyanine. The outer diameter up to 218.5 nm and the length of the well-aligned CNTs can be systematically controlled by varying the growth time. A tube-in-tube nano-structure with large and small diameters of 176 and 16.7 nm, respectively, was found. The grain sizes of the iron catalyst play an important role in controlling the CNT diameters. These results are of great importance to design new aligned CNT-based electron field emitters in the potential application of panel displays.
Spontaneous and controlled-diameter synthesis of single-walled and few-walled carbon nanotubes
NASA Astrophysics Data System (ADS)
Inoue, Shuhei; Lojindarat, Supanat; Kawamoto, Takahiro; Matsumura, Yukihiko; Charinpanitkul, Tawatchai
2018-05-01
In this study, we explored the spontaneous and controlled-diameter growth of carbon nanotubes. We evaluated the effects of catalyst density, reduction time, and a number of catalyst coating on the substrate (for multi-walled carbon nanotubes) on the diameter of single-walled carbon nanotubes and the number of layers in few-walled carbon nanotubes. Increasing the catalyst density and reduction time increased the diameters of the carbon nanotubes, with the average diameter increasing from 1.05 nm to 1.86 nm for single-walled carbon nanotubes. Finally, we succeeded in synthesizing a significant double-walled carbon nanotube population of 24%.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Standards for Grades of Table Grapes (European or Vinifera Type) 1 Definitions § 51.907 Diameter. Diameter means the greatest dimension of the berry taken at right angles to a line running from the stem to the...
Code of Federal Regulations, 2012 CFR
2012-01-01
... Standards for Grades of Table Grapes (European or Vinifera Type) 1 Definitions § 51.907 Diameter. Diameter means the greatest dimension of the berry taken at right angles to a line running from the stem to the...
Code of Federal Regulations, 2010 CFR
2010-01-01
... Standards for Grades of Table Grapes (European or Vinifera Type) 1 Definitions § 51.907 Diameter. Diameter means the greatest dimension of the berry taken at right angles to a line running from the stem to the...
The effects of hindlimb unweighting on the capacitance of rat small mesenteric veins
NASA Technical Reports Server (NTRS)
Dunbar, S. L.; Berkowitz, D. E.; Brooks-Asplund, E. M.; Shoukas, A. A.
2000-01-01
Microgravity is associated with an impaired cardiac output response to orthostatic stress. Mesenteric veins are critical in modulating cardiac filling through venoconstriction. The purpose of this study was to determine the effects of simulated microgravity on the capacitance of rat mesenteric small veins. We constructed pressure-diameter relationships from vessels of 21-day hindlimb-unweighted (HLU) rats and control rats by changing the internal pressure and measuring the external diameter. Pressure-diameter relationships were obtained both before and after stimulation with norepinephrine (NE). The pressure-diameter curves of HLU vessels were shifted to larger diameters than control vessels. NE (10(-4) M) constricted veins from control animals such that the pressure-diameter relationship was significantly shifted downward (i.e., to smaller diameters at equal pressure). NE had no effect on vessels from HLU animals. These results indicate that, after HLU, unstressed vascular volume may be increased and can no longer decrease in response to sympathetic stimulation. This may partially underlie the mechanism leading to the exaggerated fall in cardiac output and stroke volume seen in astronauts during an orthostatic stress after exposure to microgravity.
NASA Astrophysics Data System (ADS)
Torres, D.; Pinilla, J. L.; Suelves, I.
2017-12-01
Few-layer graphene oxide (FLGO) was obtained by chemical unzipping of multi-wall carbon nanotubes (MWCNT) of different diameter distributions. MWCNT were synthesized by catalytic decomposition of methane using Fe-Mo/MgO catalysts. The variation in the Fe/Mo ratio (1, 2 and 5) was very influential in MWCNT diameter distribution and type of MWCNT obtained, including textural, chemical, structural and morphological characteristics. MWCNT diameter distribution and surface defects content had a profound impact on the characteristics of the resulting FLGO. Thus, MWCNT obtained with the catalyst with a Fe/Mo: 5 and presenting a narrow diameter distribution centered at 8.6 ± 3.3 nm led to FLGO maintaining non-oxidized graphite stacking (according to XRD analysis), lower specific surface area and higher thermostability as compared to FLGO obtained from MWCNT showing wider diameter distributions. The presence of more oxygen-containing functionalities and structural defects in large diameter nanotubes promotes the intercalation of species towards the inner layers of the nanotube, resulting in an enhanced MWCNT oxidation and opening into FLGO, what improves both micro- and mesoporosity.
Cui, Kehang; Kumamoto, Akihito; Xiang, Rong; An, Hua; Wang, Benjamin; Inoue, Taiki; Chiashi, Shohei; Ikuhara, Yuichi; Maruyama, Shigeo
2016-01-21
We synthesize vertically aligned single-walled carbon nanotubes (VA-SWNTs) with subnanometer diameters on quartz (and SiO2/Si) substrates by alcohol CVD using Cu-anchored Co catalysts. The uniform VA-SWNTs with a nanotube diameter of 1 nm are synthesized at a CVD temperature of 800 °C and have a thickness of several tens of μm. The diameter of SWNTs was reduced to 0.75 nm at 650 °C with the G/D ratio maintained above 24. Scanning transmission electron microscopy energy-dispersive X-ray spectroscopy (EDS-STEM) and high angle annular dark field (HAADF-STEM) imaging of the Co/Cu bimetallic catalyst system showed that Co catalysts were captured and anchored by adjacent Cu nanoparticles, and thus were prevented from coalescing into a larger size, which contributed to the small diameter of SWNTs. The correlation between the catalyst size and the SWNT diameter was experimentally clarified. The subnanometer-diameter and high-quality SWNTs are expected to pave the way to replace silicon for next-generation optoelectronic and photovoltaic devices.
Axial contraction in etched optical fiber due to internal stress reduction.
Lim, Kok-Sing; Yang, Hang-Zhou; Chong, Wu-Yi; Cheong, Yew-Ken; Lim, Chin-Hong; Ali, Norfizah M; Ahmad, Harith
2013-02-11
When an optical fiber is dipped in an etching solution, the internal stress profile in the fiber varies with the fiber diameter. We observed a physical contraction as much as 0.2% in the fiber axial dimension when the fiber was reduced from its original diameter to ~6 µm through analysis using high resolution microscope images of the grating period of an etched FBG at different fiber diameters. This axial contraction is related to the varying axial stress profile in the fiber when the fiber diameter is reduced. On top of that, the refractive index of fiber core increases with reducing fiber diameter due to stress-optic effect. The calculated index increment is as much as 1.8 × 10(-3) at the center of fiber core after the diameter is reduced down to ~6 µm. In comparison with the conventional model that assumes constant grating period and neglects the variation in stress-induced index change in fiber core, our proposed model indicates a discrepancy as much as 3nm in Bragg wavelength at a fiber diameter of ~6 µm.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Definitions § 51.907 Diameter. Diameter means the greatest dimension of the berry taken at right angles to a line running from the stem to the blossom end. [36 FR 9126, May 20, 1971. Redesignated at 42 FR 32514...
Code of Federal Regulations, 2013 CFR
2013-01-01
... Definitions § 51.907 Diameter. Diameter means the greatest dimension of the berry taken at right angles to a line running from the stem to the blossom end. [36 FR 9126, May 20, 1971. Redesignated at 42 FR 32514...
2016-07-02
beams Superresolution machining Threshold effect of ablation means that structure diameter is less than the beam diameter fs pulses at 800 nm yield 200...Approved for public release: distribution unlimited. Applications of Bessel beams Superresolution machining Threshold effect of ablation means that... Superresolution machining Threshold effect of ablation means that structure diameter is less than the beam diameter fs pulses at 800 nm yield 200 nm
NASA Astrophysics Data System (ADS)
Majidi, R.; Karami, A. R.
2013-05-01
We have used molecular dynamics simulation to study helium adsorption capacity of carbon nanotube bundles with different diameters. Homogeneous carbon nanotube bundles of (8,8), (9,9), (10,10), (11,11), and (12,12) single walled carbon nanotubes have been considered. The results indicate that the exohedral adsorption coverage does not depend on the diameter of carbon nanotubes, while the endohedral adsorption coverage is increased by increasing the diameter.
NASA Technical Reports Server (NTRS)
Mchugh, James G; Derring, Eldridge H
1939-01-01
Report presents the results of an investigation conducted in the NACA 20-foot tunnel to determine the slipstream drag, the body interference, and the cooling characteristics of nacelle-propeller diameter. Four combinations of geometrically similar propellers and nacelles, mounted on standard wing supports, were tested with values of the ratio of nacelle diameter to propeller diameter of 0.25, 0.33, and 0.44.
Whispering Gallery Optical Resonator Spectroscopic Probe and Method
NASA Technical Reports Server (NTRS)
Anderson, Mark S. (Inventor)
2014-01-01
Disclosed herein is a spectroscopic probe comprising at least one whispering gallery mode optical resonator disposed on a support, the whispering gallery mode optical resonator comprising a continuous outer surface having a cross section comprising a first diameter and a second diameter, wherein the first diameter is greater than the second diameter. A method of measuring a Raman spectrum and an Infra-red spectrum of an analyte using the spectroscopic probe is also disclosed.
Tromp, R M; Afzali, A; Freitag, M; Mitzi, D B; Chen, Zh
2008-02-01
The problem of separating single-wall carbon nanotubes (CNTs) by diameter and/or chirality is one of the greatest impediments toward the widespread application of these promising materials in nanoelectronics. In this paper, we describe a novel physical-chemical method for diameter-selective CNT separation that is both simple and effective and that allows up-scaling to large volumes at modest cost. Separation is based on size-selective noncovalent matching of an appropriate anchor molecule to the wall of the CNT, enabling suspension of the CNTs in solvents in which they would otherwise not be soluble. We demonstrate size-selective separation in the 1-2 nm diameter range using easily synthesized oligo-acene adducts as a diameter-selective molecular anchor. CNT field effect transistors fabricated from diameter-selected CNTs show markedly improved electrical properties as compared to nonselected CNTs.
Methods and Systems for Characterization of an Anomaly Using Infrared Flash Thermography
NASA Technical Reports Server (NTRS)
Koshti, Ajay M. (Inventor)
2013-01-01
A method for characterizing an anomaly in a material comprises (a) extracting contrast data; (b) measuring a contrast evolution; (c) filtering the contrast evolution; (d) measuring a peak amplitude of the contrast evolution; (d) determining a diameter and a depth of the anomaly, and (e) repeating the step of determining the diameter and the depth of the anomaly until a change in the estimate of the depth is less than a set value. The step of determining the diameter and the depth of the anomaly comprises estimating the depth using a diameter constant C.sub.D equal to one for the first iteration of determining the diameter and the depth; estimating the diameter; and comparing the estimate of the depth of the anomaly after each iteration of estimating to the prior estimate of the depth to calculate the change in the estimate of the depth of the anomaly.
All fiber passively Q-switched laser
Soh, Daniel B. S.; Bisson, Scott E
2015-05-12
Embodiments relate to an all fiber passively Q-switched laser. The laser includes a large core doped gain fiber having a first end. The large core doped gain fiber has a first core diameter. The laser includes a doped single mode fiber (saturable absorber) having a second core diameter that is smaller than the first core diameter. The laser includes a mode transformer positioned between a second end of the large core doped gain fiber and a first end of the single mode fiber. The mode transformer has a core diameter that transitions from the first core diameter to the second core diameter and filters out light modes not supported by the doped single mode fiber. The laser includes a laser cavity formed between a first reflector positioned adjacent the large core doped gain fiber and a second reflector positioned adjacent the doped single mode fiber.
Korzekwa, David A.; Bingert, John F.; Peterson, Dean E.; Sheinberg, Haskell
1995-01-01
A superconductive article is made by inserting a rigid mandrel into an internal cavity of a first metallic tube, said tube having an interior surface and an exterior surface, said interior surface defining the interior cavity, forming a layer of a superconductive material or superconductive precursor upon the exterior surface of said first metallic tube, machining the layer of superconductive material or superconductive precursor to a predetermined diameter to form an intermediate article configured for insertion into a second metallic tube having an interior diameter corresponding to the predetermined diameter, inserting the machined intermediate article into a second metallic tube having an internal diameter corresponding to the predetermined diameter of the intermediate article to form a composite intermediate article, reducing or ironing the composite intermediate article to a predetermined cross-sectional diameter, and sintering the reduced or ironed composite intermediate article at temperatures and for time sufficient for the superconductive material or superconductive precursor to exhibit superconductivity.
Korzekwa, D.A.; Bingert, J.F.; Peterson, D.E.; Sheinberg, H.
1995-07-18
A superconductive article is made by inserting a rigid mandrel into an internal cavity of a first metallic tube, said tube having an interior surface and an exterior surface, said interior surface defining the interior cavity, forming a layer of a superconductive material or superconductive precursor upon the exterior surface of said first metallic tube, machining the layer of superconductive material or superconductive precursor to a predetermined diameter to form an intermediate article configured for insertion into a second metallic tube having an interior diameter corresponding to the predetermined diameter, inserting the machined intermediate article into a second metallic tube having an internal diameter corresponding to the predetermined diameter of the intermediate article to form a composite intermediate article, reducing or ironing the composite intermediate article to a predetermined cross-sectional diameter, and sintering the reduced or ironed composite intermediate article at temperatures and for time sufficient for the superconductive material or superconductive precursor to exhibit superconductivity. 2 figs.
1980-11-12
Range : 660,000 kilometers (400,000 miles) Time : 5:05 am PST This Voyager 1 picture of Mimas shows a large impact structure at 110 degrees W Long., located on that face of the moon which leads Mimas in its orbit. The feature, about 130 kilometers in diameter (80 miles), is more than 1/4 the diameter of the entire moon. This is a particularly interesting feature in view of its large diameter compared with the size of the satellite, and may have the largest crater diameter/satillite diameter ratio in the solar system. The crater has a raised rim and central peak, typical of large impact structures on terrestrial planets. Additional smaller craters, 15-45 kilometers in diameter, can be seen scattered across the surface, particularly alon the terminator. Mimas is one of the smaller Saturnian satellites with a low density implying its chief component is ice.
NASA Astrophysics Data System (ADS)
Xiao, Zhenggang; Xu, Fuming
2018-04-01
In order to investigate the relationship between the slivering point and burning progressivity, a set of 19-perforation propellants containing triethylene glycol dinitrate (TEGDN) with different lengths/outside diameter ratios and perforation diameters was prepared and tested in a closed vessel. The mass fraction of burnt propellant was derived from the recorded pressure-time history of 19-perforation TEGDN propellants in the closed vessel according to the gas state equation and the form function of tested propellants. Based on the form function calculation and the mass fraction of burnt propellant, instantaneous burning surface area and the burning rate were obtained. The influence of length/outside diameter ratios and perforation diameters on the progressive combustion performance is studied through the dynamic vivacity method. With an increase in the length/outsider diameter, the slivering point occurs earlier and the slivering process lasts longer. Further, the burning progressivity of surface area can be improved. For propellants with same length/outside diameter ratio, with a decreasing of perforation diameter, the slivering point lags behind and the burning progressivity becomes greater. The slivering point corresponds to the instantaneous burning area, which is related to the form function and total burning process as well. However, the total burning progressivity of propellant is a very comprehensive result of propellant under multiple actions, including the mass fraction of burnt propellant, grain size and burning rate at different pressure regions. The correlation between them can boost a better understanding on the interaction between grain size, slivering burning process and burning progressivity.
Bernstein, Eric F; Civiok, Jennifer M
2013-12-01
Laser beam diameter affects the depth of laser penetration. Q-switched lasers tend to have smaller maximum spot sizes than other dermatologic lasers, making beam diameter a potentially more significant factor in treatment outcomes. To compare the clinical effect of using the maximum-size treatment beam available for each delivered fluence during laser tattoo removal to a standard 4-mm-diameter treatment beam. Thirteen tattoos were treated in 12 subjects using a Q-switched Nd:YAG laser equipped with a treatment beam diameter that was adjustable in 1 mm increments and a setting that would enable the maximally achievable diameter ("MAX-ON" setting) with any fluence. Tattoos were randomly bisected and treated on one side with the MAX-ON setting and on the contralateral side with a standard 4-mm-diameter spot ("MAX-OFF" setting). Photographs were taken 8 weeks following each treatment and each half-tattoo was evaluated for clearance on a 10-point scale by physicians blinded to the treatment conditions. Tattoo clearance was greater on the side treated with the MAX-ON setting in a statistically significant manner following the 1st through 4th treatments, with the MAX-OFF treatment site approaching the clearance of the MAX-ON treatment site after the 5th and 6th treatments. This high-energy, Q-switched Nd:YAG laser with a continuously variable spot-size safely and effectively removes tattoos, with greater removal when using a larger spot-size. © 2013 Wiley Periodicals, Inc.
Bark thickness related to tree diameter in sugar maple (Acer saccharum Marsh.)
H. Clay Smith
1969-01-01
Bark thickness for sugar maple trees in Vermont was found to be related to tree diameter at breast height (d.b.h.). The relationship was positive-as the diameter increased, the bark thickness increased.
Shiitake mushroom production on small diameter oak logs in Ohio
S.M. Bratkovich
1991-01-01
Yields of different strains of shiitake mushrooms (Lentinus edodes) were evaluated when produced on small diameter oak logs in Ohio. Logs averaging between 3-4 inches in diameter were inoculated with four spawn strains in 1985.
Strong focusing effect of 660 nm laser by microsized tapered glass tubes with different diameters
NASA Astrophysics Data System (ADS)
Lin, Chongnan; Luo, Xujia; Zhu, Xiaoyang; Zhu, Li; Wang, Hongcheng; Zhang, Ao; Xu, Runyu; Qu, Zheng; Chen, Ximeng; Zhang, Weiyi; Shao, Jianxiong
2017-09-01
A laser with a wavelength of 660 nm was focused by microsized tapered glass tubes with different diameters of the exit. By using the 3-μm optical fiber and micrometer displacement stages, we measured the light intensity distribution around the focal spot, the focal distance, and the transmission coefficient of the light transmitted through these tubes. The focusing effect for the glass tubes with smaller outlet diameters of the exit was found to be much stronger than those with larger diameters of the exit. Furthermore, the dependence of the size and distance and the maximum intensity of the focal spot on the tubes' diameter of exit are obtained.
Correlation of Mechanical Properties with Diameter and Cooling Rate of 1080 Wire-Rod
NASA Astrophysics Data System (ADS)
Kohli, A.; Poirier, D. R.
2017-12-01
More than 540 heats of 1080 wire-rod were statistically analyzed by regression analyses to see whether tensile strength and percent reduction in area (%RA) relate to wire-rod diameter and composition. As diameter increases from 5.6 to 12.7 mm, the trend in %RA shows a decrease with negligible effect on the trend of the tensile strength. It was found that the estimated cooling rate at 700 °C during controlled cooling is responsible for the "diameter effect." The effect of composition on %RA is minor when contrasted to the "diameter effect." In particular, the effect of the concentrations of the residual elements on %RA within the compositional range studied is negligible.
Growth of nanostructures with controlled diameter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfefferle, Lisa; Haller, Gary; Ciuparu, Dragos
2009-02-03
Transition metal-substituted MCM-41 framework structures with a high degree of structural order and a narrow pore diameter distribution were reproducibly synthesized by a hydrothermal method using a surfactant and an anti-foaming agent. The pore size and the mesoporous volume depend linearly on the surfactant chain length. The transition metals, such as cobalt, are incorporated substitutionally and highly dispersed in the silica framework. Single wall carbon nanotubes with a narrow diameter distribution that correlates with the pore diameter of the catalytic framework structure were prepared by a Boudouard reaction. Nanostructures with a specified diameter or cross-sectional area can therefore be predictablymore » prepared by selecting a suitable pore size of the framework structure.« less
IR and SiO Maser Observations of Miras
NASA Astrophysics Data System (ADS)
Cotton, W. D.; Mennesson, B.; Diamond, P. J.; Perrin, G.; Coudé du Foresto, V.; Chagnon, G.; van Langevelde, H. J.; Ridgway, S.; Waters, R.; Vlemmings, W.; Morel, S.; Traub, W.; Carleton, N.; Lacasse, M.
2005-12-01
Preliminary results of a coordinated program of near IR and SiO maser interferometric observations of Mira variables are reported. The 2.2 and 3.6 micron results are from the FLUOR/TISIS beam combiners on the IOTA interferometer and the SiO maser observations from the VLBA. The ratio of the SiO ring diameter to the apparent diameter at 2.2 microns for stars in our sample cluster around 2, whereas the 3.6 micron diameters range from slightly larger than the 2.2 micron diameter to approximately the SiO ring diameter. This may be due to differences in the opacity of the molecular envelope at 3.6 microns.
Pradip Saud; Thomas B. Lynch; Anup K. C.; James M. Guldin
2016-01-01
The inclusion of quadratic mean diameter (QMD) and relative spacing index (RSI) substantially improved the predictive capacity of heightâdiameter at breast height (d.b.h.) and crown ratio models (CR), respectively. Data were obtained from 208 permanent plots established in western Arkansas and eastern Oklahoma during 1985â1987 and remeasured for the sixth time (2012â...
Method for fabricating thin californium-containing radioactive source wires
Gross, Ian G; Pierce, Larry A
2006-08-22
A method for reducing the cross-sectional diameter of a radioactive californium-containing cermet wire while simultaneously improving the wire diameter to a more nearly circular cross section. A collet fixture is used to reduce the wire diameter by controlled pressurization pulses while simultaneously improving the wire cross-sectional diameter. The method is especially suitable for use in hot cells for the production of optimized cermet brachytherapy sources that contain large amounts of radioactive californium-252.
Harris, William G.
1985-01-01
A heat limiting tubular sleeve extending over only a portion of a tube having a generally uniform outside diameter, the sleeve being open on both ends, having one end thereof larger in diameter than the other end thereof and having a wall thickness which decreases in the same direction as the diameter of the sleeve decreases so that the heat transfer through the sleeve and tube is less adjacent the large diameter end of the sleeve than adjacent the other end thereof.
NASA Astrophysics Data System (ADS)
Simakov, N. N.
2018-04-01
Page 1010, left column, line 4 from bottom should read "radius R APP" instead of "diameter D APP" Page 1010, right column, before the formula (19) should read " R APP" instead of " D APP" Page 1010, in the caption to Fig. 5 should read "radius R APP" instead of "diameter D APP" Page 1011, in the caption to Fig. 6 should read "radius R APP" instead of "diameter D APP" Page 1011, left column, second paragraph after Fig. 6, line 4 from top should read "radius R APP" instead of "diameter D APP" Page 1011, the same paragraph, lines 1, 2 from bottom, in the expression for Qm and after it should read "radius R APP" instead of "diameter D APP" Page 1011, left column, paragraph 3 after Fig. 6, last two lines should read " R APP =" instead of " D APP =" Page 1011, Fig. 7, the notation on the abscissa axis should read " R APP" instead of " D APP" Page 1011, in the caption to Fig. 7 should read "radius R APP" instead of "diameter D APP" Page 1011, in caption to Fig. 8 should read "for both radii R APP" instead of "for both diameters D APP" Page 1012, in caption to Fig. 9 should read "for both radii R APP" instead of "for both diameters D APP"
Responses of buried corrugated metal pipes to earthquakes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, C.A.; Bardet, J.P.
2000-01-01
This study describes the results of field investigations and analyses carried out on 61 corrugated metal pipes (CMP) that were shaken by the 1994 Northridge earthquake. These CMPs, which include 29 small-diameter (below 107 cm) CMPs and 32 large-diameter (above 107 cm) CMPs, are located within a 10 km{sup 2} area encompassing the Van Normal Complex in the Northern San Fernando Valley, in Los Angeles, California. During the Northridge earthquake, ground movements were extensively recorded within the study area. Twenty-eight of the small-diameter CMPs performed well while the 32 large-diameter CMPs underwent performances ranging from no damage to complete collapse.more » The main cause of damage to the large-diameter CMPs was found to be the large ground strains. Based on this unprecedented data set, the factors controlling the seismic performance of the 32 large-diameter CMPs were identified and framed into a pseudostatic analysis method for evaluating the response of large diameter flexible underground pipes subjected to ground strain. The proposed analysis, which is applicable to transient and permanent strains, is capable of describing the observed performance of large-diameter CMPs during the 1994 Northridge earthquake. It indicates that peak ground velocity is a more reliable parameter for analyzing pipe damage than is peak ground acceleration. Results of this field investigation and analysis are useful for the seismic design and strengthening of flexible buried conduits.« less
Hair root diameter measurement as an indicator of protein deficiency in nonhospitalized alcoholics.
Bregar, R R; Gordon, M; Whitney, E N
1978-02-01
Protein status of alcoholics admitted to a detoxification center was investigated with a view to adapting a hair root test for use in screening for protein deficiency. Hair root volume and hair root diameter had previously been shown to correlate well with hair root protein and to be sensitive indicators of protein deficiency. Hair root volumes in this study correlated well with mean maximum hair root diameters (n = 35, r = 0.9), which were simpler to measure, so diameter measurements were used. Mean maximum hair root diameters (range 0.02 to 0.19 mm) correlated with plasma RNase concentrations (range 6000 to 14,000 units/ml; n = 17, r = -0.7). Mean hair diameters of 84 alcoholics averaged 0.0864 +/- 0.0366 mm; those of 25 nonalcoholics were significantly greater: 0.100 +/- 0.0254 mm (P less than 0.05). Frequency of occurrence of hair root diameters of 0.06 mm or less was significantly higher in 71 alcoholics (29.5%) than in 23 nonalcoholics (8.6%) matched by age. Mean hair root diameters of 0.06 mm or less therefore can be used to signify protein deficiency where more expensive or technically demanding tests are not feasible. Protein deficiency occurs extensively in non hospitalized alcoholics. This method enables staff to single out those clients most likely to be in need of nutritional counseling and therapy.
NASA Astrophysics Data System (ADS)
Uwaba, Tomoyuki; Ito, Masahiro; Nemoto, Junichi; Ichikawa, Shoichi; Katsuyama, Kozo
2014-09-01
The BAMBOO computer code was verified by results for the out-of-pile bundle compression test with large diameter pin bundle deformation under the bundle-duct interaction (BDI) condition. The pin diameters of the examined test bundles were 8.5 mm and 10.4 mm, which are targeted as preliminary fuel pin diameters for the upgraded core of the prototype fast breeder reactor (FBR) and for demonstration and commercial FBRs studied in the FaCT project. In the bundle compression test, bundle cross-sectional views were obtained from X-ray computer tomography (CT) images and local parameters of bundle deformation such as pin-to-duct and pin-to-pin clearances were measured by CT image analyses. In the verification, calculation results of bundle deformation obtained by the BAMBOO code analyses were compared with the experimental results from the CT image analyses. The comparison showed that the BAMBOO code reasonably predicts deformation of large diameter pin bundles under the BDI condition by assuming that pin bowing and cladding oval distortion are the major deformation mechanisms, the same as in the case of small diameter pin bundles. In addition, the BAMBOO analysis results confirmed that cladding oval distortion effectively suppresses BDI in large diameter pin bundles as well as in small diameter pin bundles.
MreB Orientation Correlates with Cell Diameter in Escherichia coli.
Ouzounov, Nikolay; Nguyen, Jeffrey P; Bratton, Benjamin P; Jacobowitz, David; Gitai, Zemer; Shaevitz, Joshua W
2016-09-06
Bacteria have remarkably robust cell shape control mechanisms. For example, cell diameter only varies by a few percent across a given population. The bacterial actin homolog, MreB, is necessary for establishment and maintenance of rod shape although the detailed properties of MreB that are important for shape control remained unknown. In this study, we perturb MreB in two ways: by treating cells with the polymerization-inhibiting drug A22 and by creating point mutants in mreB. These perturbations modify the steady-state diameter of cells over a wide range, from 790 ± 30 nm to 1700 ± 20 nm. To determine which properties of MreB are important for diameter control, we correlated structural characteristics of fluorescently tagged MreB polymers with cell diameter by simultaneously analyzing three-dimensional images of MreB and cell shape. Our results indicate that the helical pitch angle of MreB inversely correlates with the cell diameter of Escherichia coli. Other correlations between MreB and cell diameter are not found to be significant. These results demonstrate that the physical properties of MreB filaments are important for shape control and support a model in which MreB organizes the cell wall growth machinery to produce a chiral cell wall structure and dictate cell diameter. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Szlavik, Robert B
2016-02-01
The characterization of peripheral nerve fiber distributions, in terms of diameter or velocity, is of clinical significance because information associated with these distributions can be utilized in the differential diagnosis of peripheral neuropathies. Electro-diagnostic techniques can be applied to the investigation of peripheral neuropathies and can yield valuable diagnostic information while being minimally invasive. Nerve conduction velocity studies are single parameter tests that yield no detailed information regarding the characteristics of the population of nerve fibers that contribute to the compound-evoked potential. Decomposition of the compound-evoked potential, such that the velocity or diameter distribution of the contributing nerve fibers may be determined, is necessary if information regarding the population of contributing nerve fibers is to be ascertained from the electro-diagnostic study. In this work, a perturbation-based decomposition of compound-evoked potentials is proposed that facilitates determination of the fiber diameter distribution associated with the compound-evoked potential. The decomposition is based on representing the single fiber-evoked potential, associated with each diameter class, as being perturbed by contributions, of varying degree, from all the other diameter class single fiber-evoked potentials. The resultant estimator of the contributing nerve fiber diameter distribution is valid for relatively large separations in diameter classes. It is also useful in situations where the separation between diameter classes is small and the concomitant single fiber-evoked potentials are not orthogonal.
Douglas, Anna; Carter, Rachel; Li, Mengya; Pint, Cary L
2018-06-06
Small-diameter carbon nanotubes (CNTs) often require increased sophistication and control in synthesis processes, but exhibit improved physical properties and greater economic value over their larger-diameter counterparts. Here, we study mechanisms controlling the electrochemical synthesis of CNTs from the capture and conversion of ambient CO 2 in molten salts and leverage this understanding to achieve the smallest-diameter CNTs ever reported in the literature from sustainable electrochemical synthesis routes, including some few-walled CNTs. Here, Fe catalyst layers are deposited at different thicknesses onto stainless steel to produce cathodes, and atomic layer deposition of Al 2 O 3 is performed on Ni to produce a corrosion-resistant anode. Our findings indicate a correlation between the CNT diameter and Fe metal layer thickness following electrochemical catalyst reduction at the cathode-molten salt interface. Further, catalyst coarsening during long duration synthesis experiments leads to a 2× increase in average diameters from 3 to 60 min durations, with CNTs produced after 3 min exhibiting a tight diameter distribution centered near ∼10 nm. Energy consumption analysis for the conversion of CO 2 into CNTs demonstrates energy input costs much lower than the value of CNTs-a concept that strictly requires and motivates small-diameter CNTs-and is more favorable compared to other costly CO 2 conversion techniques that produce lower-value materials and products.
Increased depth-diameter ratios in the Medusae Fossae Formation deposits of Mars
NASA Technical Reports Server (NTRS)
Barlow, N. G.
1993-01-01
Depth to diameter ratios for fresh impact craters on Mars are commonly cited as approximately 0.2 for simple craters and 0.1 for complex craters. Recent computation of depth-diameter ratios in the Amazonis-Memnonia region of Mars indicates that craters within the Medusae Fossae Formation deposits found in this region display greater depth-diameter ratios than expected for both simple and complex craters. Photoclinometric and shadow length techniques have been used to obtain depths of craters within the Amazonis-Memnonia region. The 37 craters in the 2 to 29 km diameter range and displaying fresh impact morphologies were identified in the area of study. This region includes the Amazonian aged upper and middle members of the Medusae Fossae Formation and Noachian aged cratered and hilly units. The Medusae Fossae Formation is characterized by extensive, flat to gently undulating deposits of controversial origin. These deposits appear to vary from friable to indurated. Early analysis of crater degradation in the Medusae Fossae region suggested that simple craters excavated to greater depths than expected based on the general depth-diameter relationships derived for Mars. However, too few craters were available in the initial analysis to estimate the actual depth-diameter ratios within this region. Although the analysis is continuing, we are now beginning to see a convergence towards specific values for the depth-diameter ratio depending on geologic unit.
Ding, Xi; Zhu, Xing-Hao; Liao, Sheng-Hui; Zhang, Xiu-Hua; Chen, Hong
2009-07-01
To establish a 3D finite element model of a mandible with dental implants for immediate loading and to analyze stress distribution in bone around implants of different diameters. Three mandible models, embedded with thread implants (ITI, Straumann, Switzerland) with diameters of 3.3, 4.1, and 4.8 mm, respectively, were developed using CT scanning and self-developed Universal Surgical Integration System software. The von Mises stress and strain of the implant-bone interface were calculated with the ANSYS software when implants were loaded with 150 N vertical or buccolingual forces. When the implants were loaded with vertical force, the von Mises stress concentrated on the mesial and distal surfaces of cortical bone around the neck of implants, with peak values of 25.0, 17.6 and 11.6 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains (5854, 4903, 4344 muepsilon) were located on the buccal cancellous bone around the implant bottom and threads of implants. The stress and strain were significantly lower (p < 0.05) with the increased diameter of implant. When the implants were loaded with buccolingual force, the peak von Mises stress values occurred on the buccal surface of cortical bone around the implant neck, with values of 131.1, 78.7, and 68.1 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains occurred on the buccal surface of cancellous bone adjacent to the implant neck, with peak values of 14,218, 12,706, and 11,504 microm, respectively. The stress of the 4.1-mm diameter implants was significantly lower (p < 0.05) than those of 3.3-mm diameter implants, but not statistically different from that of the 4.8 mm implant. With an increase of implant diameter, stress and strain on the implant-bone interfaces significantly decreased, especially when the diameter increased from 3.3 to 4.1 mm. It appears that dental implants of 10 mm in length for immediate loading should be at least 4.1 mm in diameter, and uniaxial loading to dental implants should be avoided or minimized.
Son, Jee Young; Ko, Sung Min; Choi, Jin Woo; Song, Meong Gun; Hwang, Hweung Kon; Lee, Sook Jin; Kang, Joon-Won
2011-12-01
We aimed to evaluate the diagnostic performance of dual-source computed tomography coronary angiography (DSCT-CA) in the measurement of the ascending aorta (AA) diameter and compare the AA diameter in patients with severe bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) stenosis. Eighty-eight consecutive patients (50 men, mean age 60.3 ± 13 year) with severe aortic stenosis (AS) underwent DSCT-CA before aortic valve surgery. Seventy-four of the 88 patients underwent cardiovascular magnetic resonance (CMR). The internal diameter of AA was measured from early-systole with DSCT-CA and CMR by 2 radiologists independently at 4 levels (aortic annulus, sinuses of Valsalva, sinotubular junction, and tubular portion at the right pulmonary artery). The patients were divided in to 2 groups (BAV [n = 53]; TAV [n = 35]) according to operative findings. Patients with BAV were significantly younger than those with TAV (P = 0.0035). Inter-observer agreement of AA diameters at 4 levels with DSCT-CA and CMR was excellent (intraclass correlation coefficient = 0.89-0.97). Also, the DSCT-CA and CMR measurements of the AA diameter strongly correlated (r = 0.871-0.976). Mean diameter of the AA by DSCT-CA was significantly larger in patients with BAV (34.4 ± 8.2 mm) as compared to those with TAV (30.6 ± 5.5 mm). The diameters at the sinuses of Valsalva, sinotubular junction, and tubular portion were significantly larger in BAV than in TAV. Twenty-two of 53 (41.5%) patients with BAV and 2 of 35 (5.7%) patients with TAV had AA dilatation > 45 mm. DSCT-CA allows accurate assessment of the AA diameters in patients with severe AS. Patients with severe BAV stenosis had larger AA diameters and higher prevalence of AA dilatation > 45 mm as compared to those with severe TAV stenosis.
Influence of the implant-abutment connection design and diameter on the screw joint stability.
Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung; Jeong, Chang-Mo
2014-04-01
This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). THE POSTLOAD REMOVAL TORQUE VALUE WAS HIGH IN THE FOLLOWING ORDER WITH REGARD TO MAGNITUDE: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate.
Distal Ureteral Diameter Ratio is Predictive of Breakthrough Febrile Urinary Tract Infection.
Arlen, Angela M; Leong, Traci; Guidos, P Joseph; Alexander, Siobhan E; Cooper, Christopher S
2017-12-01
Distal ureteral diameter ratio is an objective measure that is prognostic of spontaneous resolution of vesicoureteral reflux. Along with likelihood of resolution, improved identification of children at risk for recurrent febrile urinary tract infections may impact management decisions. We evaluated the usefulness of ureteral diameter ratio as a predictive factor for breakthrough febrile urinary tract infections. Children with primary vesicoureteral reflux and detailed voiding cystourethrogram were identified. Ureteral diameter ratio was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between L1 and L3 vertebral bodies. Demographics, vesicoureteral reflux grade, laterality, presence/absence of bladder-bowel dysfunction, and ureteral diameter ratio were tested in univariate and multivariable analyses. Primary outcome was breakthrough febrile urinary tract infections. We analyzed 112 girls and 28 boys with a mean ± SD age of 2.5 ± 2.3 years at diagnosis. Vesicoureteral reflux was grade 1 to 2 in 64 patients (45.7%), grade 3 in 50 (35.7%), grade 4 in 16 (11.4%) and grade 5 in 10 (7.2%). Mean ± SD followup was 3.2 ± 2.7 years. A total of 40 children (28.6%) experienced breakthrough febrile urinary tract infections. Ureteral diameter ratio was significantly greater in children with (0.36) vs without (0.25) breakthrough febrile infections (p = 0.004). Controlling for vesicoureteral reflux grade, every 0.1 U increase in ureteral diameter ratio resulted in 1.7 times increased odds of breakthrough infection (95% CI 1.24 to 2.26, p <0.0001). Children with increased distal ureteral diameter ratio are at greater risk for breakthrough febrile urinary tract infections independent of reflux grade. Ureteral diameter ratio provides valuable prognostic information about risk of recurrent pyelonephritis and may assist with clinical decision-making. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hwang, Da Young; Suh, Dong Hack
2014-05-01
Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs.Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr00897a
Effect of distributor on performance of a continuous fluidized bed dryer
NASA Astrophysics Data System (ADS)
Yogendrasasidhar, D.; Srinivas, G.; Pydi Setty, Y.
2018-03-01
Proper gas distribution is very important in fluidized bed drying in industrial practice. Improper distribution of gas may lead to non-idealities like channeling, short circuiting and accumulation which gives rise to non-uniform quality of dried product. Gas distribution depends on the distributor plate used. Gas distribution mainly depends on orifice diameter, number of orifices and opening area of the distributor plate. Small orifice diameter leads to clogging, and a large orifice diameter gives uneven distribution of gas. The present work involves experimental studies using different distributor plates and simulation studies using ASPEN PLUS steady state simulator. The effect of various parameters such as orifice diameter, number of orifices and the opening area of the distributor plate on the performance of fluidized bed dryer have been studied through simulation and experimentation. Simulations were carried out (i) with increasing air inlet temperature to study the characteristics of solid temperature and moisture in outlet (ii) with increasing orifice diameter and (iii) with increase in number orifices to study the solid outlet temperature profiles. It can be observed from the simulation that, an increase in orifice diameter and number orifices increases solid outlet temperature upto certain condition and then after there is no effect with further increase. Experiments were carried out with increasing opening area (3.4 to 42%) in the form of increasing orifice diameter keeping the number of orifices constant and increasing number of orifices of the distributor plate keeping the orifice diameter constant. It can be seen that the drying rate and solid outlet temperature increase upto certain condition and then after with further increase in the orifice diameter and number of orifices, the change in the drying rate and solid outlet temperature observed is little. The optimum values of orifice diameter and number of orifices from experimentation are found to be 5 mm and 60 (22% opening area).
Evaluation of normal abdominal aortic diameters in the Indian population using computed tomography.
Jasper, A; Harshe, G; Keshava, S N; Kulkarni, G; Stephen, E; Agarwal, S
2014-01-01
The aim of this study was to establish normal diameters for the suprarenal and infrarenal abdominal aorta measured at T12 and L3 vertebral levels in the Indian population and to study the variation in aortic diameters with age, sex, height, weight, body mass index (BMI), and body surface area (BSA). One hundred and forty-two patients who underwent helical contrast-enhanced computed tomography (CT) scans of the abdomen for non-cardiovascular reasons were recruited.. The mean internal diameters of the suprarenal and infrarenal abdominal aorta (maximum anteroposterior and transverse diameter) were measured at T12 and L3 vertebral levels and tabulated according to various age groups for both men and women. Pearson correlation coefficient was used to evaluate the correlation between aortic diameters, height, weight, BSA, and BMI. The mean diameters of the suprarenal and infrarenal abdominal aorta measured at T12 and L3 vertebral levels, in men were 19.0 ± 2.3 and 13.8 ± 1.9 mm and in women 17.1 ± 2.3 and 12.0 ± 1.6 mm, respectively. The aortic diameter progressively increased in caliber with increasing age of the patients and was smaller in women than men. A significant positive correlation was found in men between the suprarenal and infrarenal aortic diameters and weight, BSA, and BMI. In women, this correlation was significant in the infrarenal aorta but not in the suprarenal aorta. We obtained a set of normal values for the abdominal aorta in the Indian population. The aortic diameters correlated with age, gender, and body size of the patients as seen with previously published data in the Western population. A brief comparison of data between Indian and Western population showed that the values obtained were less than published elsewhere and hence, this should be considered while formulating intervention protocols.
Stress changes ahead of an advancing tunnel
Abel, J.F.; Lee, F.T.
1973-01-01
Instrumentation placed ahead of three model tunnels in the laboratory and ahead of a crosscut driven in a metamorphic rock mass detected stress changes several tunnel diameters ahead of the tunnel face. Stress changes were detected 4 diameters ahead of a model tunnel drilled into nearly elastic acrylic, 2??50 diameters ahead of a model tunnel drilled into concrete, and 2 diameters ahead of a model tunnel drilled into Silver Plume Granite. Stress changes were detected 7??50 diameters ahead of a crosscut driven in jointed, closely foliated gneisses and gneissic granites in an experimental mine at Idaho Springs, Colorado. These results contrast markedly with a theoretical elastic estimate of the onset of detectable stress changes at 1 tunnel diameter ahead of the tunnel face. A small compressive stress concentration was detected 2 diameters ahead of the model tunnel in acrylic, 1.25 diameters ahead of the model tunnel in concrete, and 1 diameter ahead of the model tunnel in granite. A similar stress peak was detected about 6 diameters ahead of the crosscut. No such stress peak is predicted from elastic theory. The 3-dimensional in situ stress determined in the field demonstrate that geologic structure controls stress orientations in the metamorphic rock mass. Two of the computed principal stresses are parallel to the foliation and the other principal stress is normal to it. The principal stress orientations vary approximately as the foliation attitude varies. The average horizontal stress components and the average vertical stress component are three times and twice as large, respectively, as those predicted from the overburden load. An understanding of the measured stress field appears to require the application of either tectonic or residual stress components, or both. Laboratory studies indicate the presence of proportionately large residual stresses. Mining may have triggered the release of strain energy, which is controlled by geologic structure. ?? 1973.
Zhang, Hai Ping; Li, Feng Ri; Dong, Li Hu; Liu, Qiang
2017-06-18
Based on the 212 re-measured permanent plots for natural Betula platyphylla fore-sts in Daxing'an Mountains and Xiaoxing'an Mountains and 30 meteorological stations data, an individual tree growth model based on meteorological factors was constructed. The differences of stand and meteorological factors between Daxing'an Mountains and Xiaoxing'an Mountains were analyzed and the diameter increment model including the regional effects was developed by dummy variable approach. The results showed that the minimum temperature (T g min ) and mean precipitation (P g m ) in growing season were the main meteorological factors which affected the diameter increment in the two study areas. T g min and P g m were positively correlated with the diameter increment, but the influence strength of T g min was obviously different between the two research areas. The adjusted coefficient of determination (R a 2 ) of the diameter increment model with meteorological factors was 0.56 and had an 11% increase compared to the one without meteorological factors. It was concluded that meteorological factors could well explain the diameter increment of B. platyphylla. R a 2 of the model with regional effects was 0.59, and increased by 18% compared to the one without regional effects, and effectively solved the incompatible problem of parameters between the two research areas. The validation results showed that the individual tree diameter growth model with regional effect had the best prediction accuracy in estimating the diameter increment of B. platyphylla. The mean error, mean absolute error, mean error percent and mean prediction error percent were 0.0086, 0.4476, 5.8% and 20.0%, respectively. Overall, dummy variable model of individual tree diameter increment based on meteorological factors could well describe the diameter increment process of natural B. platyphylla in Daxing'an Mountains and Xiaoxing'an Mountains.
Influence of the implant-abutment connection design and diameter on the screw joint stability
Shin, Hyon-Mo; Huh, Jung-Bo; Yun, Mi-Jeong; Jeon, Young-Chan; Chang, Brian Myung
2014-01-01
PURPOSE This study was conducted to evaluate the influence of the implant-abutment connection design and diameter on the screw joint stability. MATERIALS AND METHODS Regular and wide-diameter implant systems with three different joint connection designs: an external butt joint, a one-stage internal cone, and a two-stage internal cone were divided into seven groups (n=5, in each group). The initial removal torque values of the abutment screw were measured with a digital torque gauge. The postload removal torque values were measured after 100,000 cycles of a 150 N and a 10 Hz cyclic load had been applied. Subsequently, the rates of the initial and postload removal torque losses were calculated to evaluate the effect of the joint connection design and diameter on the screw joint stability. Each group was compared using Kruskal-Wallis test and Mann-Whitney U test as post-hoc test (α=0.05). RESULTS The postload removal torque value was high in the following order with regard to magnitude: two-stage internal cone, one-stage internal cone, and external butt joint systems. In the regular-diameter group, the external butt joint and one-stage internal cone systems showed lower postload removal torque loss rates than the two-stage internal cone system. In the wide-diameter group, the external butt joint system showed a lower loss rate than the one-stage internal cone and two-stage internal cone systems. In the two-stage internal cone system, the wide-diameter group showed a significantly lower loss rate than the regular-diameter group (P<.05). CONCLUSION The results of this study showed that the external butt joint was more advantageous than the internal cone in terms of the postload removal torque loss. For the difference in the implant diameter, a wide diameter was more advantageous in terms of the torque loss rate. PMID:24843398
NASA Astrophysics Data System (ADS)
Tamiya, Shuhei; Sato, Taiga; Kushida, Masahito
2018-03-01
Vertically aligned carbon nanotubes (VA-CNTs) are suggested for utilization as a new catalyst support of polymer electrolyte fuel cells (PEFCs). The independent control of the diameter and number density of VA-CNTs is essential for application in PEFCs. As the catalyst for VA-CNT growth, we fabricated CoFe2O4 nanoparticle (NP) films using the Langmuir-Blodgett (LB) technique. Using the LB technique, we were able to separately control the diameter and number density of VA-CNTs. The number density of VA-CNTs was changed by mixing with the filler moleculer, palmitic acid (C16). The VA-CNT diameter was changed by the adjusting the CoFe2O4 NP diameter. However, the heat-induced aggregation of CoFe2O4 NPs occurred in thermal chemical vapor deposition to synthesize VA-CNTs. Therefore, we examined how to minimize the effect of heat-induced aggregation of CoFe2O4 NPs. As a result, selection of the appropriate number density and diameter of CoFe2O4 NPs was found to be important for the control of VA-CNT diameter.
Methanol Droplet Extinction in Carbon-Dioxide-Enriched Environments in Microgravity
NASA Technical Reports Server (NTRS)
Hicks, Michael C.; Nayagam, Vedha; Williams, Forman A.
2010-01-01
Diffusive extinction of methanol droplets with initial diameters between 1.25 mm and 1.72 mm, burning in a quiescent microgravity environment at one atmosphere pressure, was obtained experimentally for varying levels of ambient carbon-dioxide concentrations with a fixed oxygen concentration of 21% and a balance of nitrogen. These experiments serve as precursors to those which are beginning to be performed on the International Space Station and are motivated by the need to understand the effectiveness of carbon-dioxide as a fire suppressant in low-gravity environments. In these experiments, the flame standoff distance, droplet diameter, and flame radiation are measured as functions of time. The results show that the droplet extinction diameter depends on both the initial droplet diameter and the ambient concentration of carbon dioxide. Increasing the initial droplet diameter leads to an increased extinction diameter, while increasing the carbon-dioxide concentration leads to a slight decrease in the extinction diameter. These results are interpreted using a critical Damk hler number for extinction as predicted by an earlier theory, which is extended here to be applicable in the presence of effects of heat conduction along the droplet support fibers and of the volume occupied by the support beads
Chou, Ching-Yu; Chen, Li-Ching; Cheong, Mei-Leng; Tsai, Ming-Song
2015-10-01
To examine the association of antenatal renal pelvic dilatation observed on midtrimester ultrasound screening with the presence of hydronephrosis in newborn infants. The records of patients who received fetal ultrasound examination at 18-28 weeks' gestation from May 2008 to March 2012 were retrospectively reviewed. A fetal renal pelvic anterior-posterior (AP) diameter > 4 mm was considered abnormal and ≤ 4 mm was considered normal. On postnatal ultrasound, a renal pelvic AP diameter > 3 mm was considered to indicate hydronephrosis and ≤ 3 mm was considered normal. The association of postnatal hydronephrosis with prenatal pelvic AP diameter was determined using binary logistic regression analysis. The study comprised 1310 newborn infants: 684 (52.2%) male and 626 (47.8%) female. Multivariate analysis showed a right or left prenatal AP renal pelvic diameter > 4 mm was associated with a higher risk of postnatal hydronephrosis compared with a right and left prenatal AP renal pelvic diameter ≤ 4 mm. Boys had a higher risk for postnatal hydronephrosis than girls (odds ratio = 2.42, p < 0.05). An antenatal renal pelvic AP diameter > 4 mm on midtrimester ultrasound is predictive of postnatal hydronephrosis. Copyright © 2015. Published by Elsevier B.V.
Gallium ion-assisted room temperature synthesis of small-diameter ZnO nanorods.
Cho, Seungho; Kim, Semi; Lee, Kun-Hong
2011-09-15
We report a method for synthesizing small-diameter ZnO nanorods at room temperature (20 °C), under normal atmospheric pressure (1 atm), and using a relatively short reaction time (1 h) by adding gallium salts to the reaction solution. The ZnO nanorods were, on average, 92 nm in length and 9 nm in diameter and were single crystalline in nature. Quantitative analyses revealed that gallium atoms were not incorporated into the synthesized nanocrystals. On the basis of the experimental results, we propose a mechanism for the formation of small-diameter ZnO nanorods in the presence of gallium ions. The optical properties were probed by UV-Vis diffuse reflectance spectroscopy. The absorption band of the small-diameter ZnO nanorods was blue-shifted relative to the absorption band of the ~230 nm diameter ZnO nanorods (control samples). Control experiments demonstrated that the absence of metal ion-containing precipitants (except ZnO) at room temperature is essential, and that the ZnO nanorod diameter distributions were narrow for the stirred reaction solution and broad when prepared without stirring. Copyright © 2011 Elsevier Inc. All rights reserved.
Verelst, M; Leivseth, G
2004-01-01
The purpose of this study was to investigate whether there is a relationship between changes in the diameter of the urogenital hiatus and force developed in pelvic floor musculature. In addition, we wanted to examine the reliability of the method that measures force development in the pelvic floor in the transverse direction of the urogenital hiatus. Passive and total force in the pelvic floor was measured with an intra-vaginal device in 20 healthy parous volunteers. The measurements were done with a consecutively increasing diameter in the transverse plane of the urogenital hiatus. The procedure was repeated with a few days interval. The measurements show an increase in force with an increasing device-diameter. The results are reliable at all the diameters tested, estimated by the within-subject day-to-day variability which was non-significant. The 40 mm diameter device is most favourable, estimated by Bland Altman plots of the test-retest measurements. Force development in pelvic floor muscles increased as a function of vaginal diameter when measured in the frontal plane. The measurements were reliable at all the different diameters chosen. 2004 Wiley-Liss, Inc.
Owolabi, Mayowa O; Agunloye, Atinuke M; Ogunniyi, Adesola
2014-01-01
Chronic changes in flow rate through arteries produce adjustment of arterial diameters. We compared the relationship between flow velocity and diameter in the carotid and in the vertebral arteries of stroke patients. Using triplex ultrasonography, the internal diameter and flow velocities of the common carotid, internal carotid, and vertebral arteries of 176 consecutive stroke patients were measured. Correlations were examined with Pearson's statistics at an alpha level of 0.05. Mean age of the patients was 59.3 ± 12 years, and 66% had cerebral infarcts. Diameter and blood flow velocities showed significant negative correlations (-0.115 ≥ r ≥ -0.382) in the carotid arteries on both sides, but positive correlations (0.211 ≤ r ≤ 0.320) in the vertebral arteries, even after controlling for age, gender, and blood pressure. Our study demonstrated different diameter/flow relationships in the carotid and the vertebral arteries of stroke patients, which may suggest pathologic changes in the adaptive processes governing vessel diameter and growth, especially in the carotid arteries. Copyright © 2013 Wiley Periodicals, Inc.
Shrinking plastic tubing and nonstandard diameters
NASA Technical Reports Server (NTRS)
Ruiz, W. V.; Thatcher, C. S.
1980-01-01
Process allows larger-than-normal postshrink diameters without splitting. Tetrafluoroethylene tubing on mandrel is supported within hot steel pipe by several small diameter coil sections. Rising temperature of mandrel is measured via thermocouple so assembly can be removed without overshrinking (and splitting) of tubing.
Implementation of 0.7 in. diameter strands in prestressed concrete girders.
DOT National Transportation Integrated Search
2013-03-01
For several years, 0.7 in. diameter strands have been successfully used in cable bridges and for mining applications. Using these large diameter strands at 2 in. by 2 in. spacing in pretensioned concrete girders results in approximately 35% increase ...
AAFE large deployable antenna development program: Executive summary
NASA Technical Reports Server (NTRS)
1977-01-01
The large deployable antenna development program sponsored by the Advanced Applications Flight Experiments of the Langley Research Center is summarized. Projected user requirements for large diameter deployable reflector antennas were reviewed. Trade-off studies for the selection of a design concept for 10-meter diameter reflectors were made. A hoop/column concept was selected as the baseline concept. Parametric data are presented for 15-meter, 30-meter, and 100-meter diameters. A 1.82-meter diameter engineering model which demonstrated the feasiblity of the concept is described.
MM&T for Linear Resonant Cooler. Volume 1
1988-02-16
Tesla *Magnet Material Samarium Cobalt Radially Magnetized Inner Diameter = 1.25" Length = 0.79" Coil Assembly Number of Turns/Section = 90 Outside...Diameter = 1.22" Inside Diameter = 0.86" Inner Iron Material 2 V Permendur Inside Diameter = 0.38" Length 1.84" Design Max. Flux Density = 2.4 Tesla 0 3-12...suspended with rubber bands 60 inches above the floor of the semi -anechoic room. A six foot square piece of 2 inch thick foam was centered on the floor
Structural and electronic properties of rectangular CdTe nanowire: A DST study
NASA Astrophysics Data System (ADS)
Khan, Md. Shahzad; Bhatia, Manjeet; Srivastava, Anurag
2018-05-01
CdTe rectangular nanowire of different diameter in zinc-blende phase is investigated using density functional theory. Enhancement of diameter increased stability and improved electronic qualities suitable for device purpose applications. Cohesive energy per atom enhanced on enlarging diameter advocating the stability. Large diameter nanowire (22.62Å) exhibits bandgap of 1.21eV and electronic effective mass is observed to be 0.51me. The bonding between Cd-Te atoms are predominantly observed as covalent assuring its inertness towards moisture.
Thermodynamic, Transport and Chemical Properties of Reference JP-8
2006-06-01
external diameter, 0.18 cm internal diameter) that are sealed on one end with a stainless steel plug welded by a clean tungsten-inert-gas ( TIG ) 15...tubing with an internal diameter of 0.02 cm, also TIG welded to the cell. Each cell and valve is capable of withstanding a pressure in excess of 105... process . Each cell is connected to a high-pressure high-temperature valve at the other end with a short length of 0.16 cm diameter 316 stainless steel
Apparatus and method for classifying fuel pellets for nuclear reactor
Wilks, Robert S.; Sternheim, Eliezer; Breakey, Gerald A.; Sturges, Jr., Robert H.; Taleff, Alexander; Castner, Raymond P.
1984-01-01
Control for the operation of a mechanical handling and gauging system for nuclear fuel pellets. The pellets are inspected for diameters, lengths, surface flaws and weights in successive stations. The control includes, a computer for commanding the operation of the system and its electronics and for storing and processing the complex data derived at the required high rate. In measuring the diameter, the computer enables the measurement of a calibration pellet, stores that calibration data and computes and stores diameter-correction factors and their addresses along a pellet. To each diameter measurement a correction factor is applied at the appropriate address. The computer commands verification that all critical parts of the system and control are set for inspection and that each pellet is positioned for inspection. During each cycle of inspection, the measurement operation proceeds normally irrespective of whether or not a pellet is present in each station. If a pellet is not positioned in a station, a measurement is recorded, but the recorded measurement indicates maloperation. In measuring diameter and length a light pattern including successive shadows of slices transverse for diameter or longitudinal for length are projected on a photodiode array. The light pattern is scanned electronically by a train of pulses. The pulses are counted during the scan of the lighted diodes. For evaluation of diameter the maximum diameter count and the number of slices for which the diameter exceeds a predetermined minimum is determined. For acceptance, the maximum must be less than a maximum level and the minimum must exceed a set number. For evaluation of length, the maximum length is determined. For acceptance, the length must be within maximum and minimum limits.
Cervical spinal canal narrowing in idiopathic syringomyelia.
Struck, Aaron F; Carr, Carrie M; Shah, Vinil; Hesselink, John R; Haughton, Victor M
2016-08-01
The cervical spine in Chiari I patient with syringomyelia has significantly different anteroposterior diameters than it does in Chiari I patients without syringomyelia. We tested the hypothesis that patients with idiopathic syringomyelia (IS) also have abnormal cervical spinal canal diameters. The finding in both groups may relate to the pathogenesis of syringomyelia. Local institutional review boards approved this retrospective study. Patients with IS were compared to age-matched controls with normal sagittal spine MR. All subjects had T1-weighted spin-echo (500/20) and T2-weighted fast spin-echo (2000/90) sagittal cervical spine images at 1.5 T. Readers blinded to demographic data and study hypothesis measured anteroposterior diameters at each cervical level. The spinal canal diameters were compared with a Mann-Whitney U test. The overall difference was assessed with a Friedman test. Seventeen subjects were read by two reviewers to assess inter-rater reliability. Fifty IS patients with 50 age-matched controls were studied. IS subjects had one or more syrinxes varying from 1 to 19 spinal segments. Spinal canal diameters narrowed from C1 to C3 and then enlarged from C5 to C7 in both groups. Diameters from C2 to C4 were narrower in the IS group (p < 0.005) than in controls. The ratio of the C3 to the C7 diameters was also smaller (p = 0.004) in IS than controls. Collectively, the spinal canal diameters in the IS were significantly different from controls (Friedman test p < 0.0001). Patients with IS have abnormally narrow upper and mid cervical spinal canal diameters and greater positive tapering between C3 and C7.
Chest diameter ratios for detecting static hyperinflation in children using photogrammetry.
Ricieri, Denise da V; Rosário, Nelson A; Costa, Jecilene R
2008-01-01
To develop a photogrammetric method capable of identifying increases in anteroposterior chest diameters suggestive of pulmonary hyperinflation, and to test it with both asthmatic and asthma-free children. Two distinct study designs were used to achieve these two objectives. The first was a descriptive analysis of diameters measured at the height of the axilla and of the xiphoid on digital images of 56 children aged 8 to 12 years photographed in the orthostatic position. The second was a case-control study of (a) 19 asthmatic children in treatment for at least 12 months; and (b) 37 children free from asthma with no prior history of complaints of respiratory/allergic disease. Diameters were measured on images of the front and left side views using CorelDRAW, and the ratio between the front and side diameters was calculated for the axillary and xiphoid measurements, providing the diameter ratios. Diameter ratios close to or greater than 1 represent geometry tending towards a cylindrical shape, typical of hyperinflation on radiographs. Analysis with the t test for independent samples revealed a mean diameter ratio at the sternum that was significantly greater in the group of asthmatic children (p < 0.01) than the mean for the whole sample and also than the mean for the children without asthma. Despite the existence of disagreement on the best instruments, methods and times for identifying hyperinflation, results indicate that a system using diameter ratios obtained by photogrammetry is a promising tool for the identification of a kinesiopathological manifestation that is known to determine air entrapment in asthma patients. Research that combines clinical data with longitudinal intrapatient follow-up will be necessary to establish the strength of the evidence found in this study.
Pan, Ying; Zhang, Yunshu; Peng, Yan; Zhao, Qinghua; Sun, Shucun
2015-01-01
Aquatic microcosm studies often increase either chamber height or base diameter (to increase water volume) to test spatial ecology theories such as "scale" effects on ecological processes, but it is unclear whether the increase of chamber height or base diameter have the same effect on the processes, i.e., whether the effect of the shape of three-dimensional spaces is significant. We orthogonally manipulated chamber height and base diameter and determined swimming activity, average swimming velocity and grazing rates of the cladocerans Daphnia magna and Moina micrura (on two algae Scenedesmus quadricauda and Chlorella vulgaris; leading to four aquatic algae-cladoceran systems in total) under different microcosm conditions. Across all the four aquatic systems, increasing chamber height at a given base diameter significantly decreased the duration and velocity of horizontal swimming, and it tended to increase the duration but decrease the velocity of vertical swimming. These collectively led to decreases in both average swimming velocity and grazing rate of the cladocerans in the tall chambers (at a given base diameter), in accordance with the positive relationship between average swimming velocity and grazing rate. In contrast, an increase of base diameter at a given chamber height showed contrasting effects on the above parameters. Consistently, at a given chamber volume increasing ratio of chamber height to base diameter decreased the average swimming velocity and grazing rate across all the aquatic systems. In general, increasing chamber depth and base diameter may exert contrasting effects on zooplankton behavior and thus phytoplankton-zooplankton interactions. We suggest that spatial shape plays an important role in determining ecological process and thus should be considered in a theoretical framework of spatial ecology and also the physical setting of aquatic microcosm experiments.
[The tuberculin skin test in BCG-vaccinated individualse].
Miret Cuadras, P; Pina Gutiérrez, J M
1998-10-01
The aim of this study was to evaluate the tuberculin skin test in individuals vaccinated with bacillus Calmette-Guérin (BCG) using 2 IU of RT-23. One hundred ninety-six individuals aged 22-40 years-old who had been vaccinated with BCG between 1965 and 1974 were enrolled along with 375 non-vaccinated individuals of the same age and with similar level of risk of infection. The positive predictive value of the test was assessed for three levels of response as indicated by areas of thickening in three diameters: 5, 10 and 15 mm. Vaccinated individuals with negative results were given a second skin test 7 days later to detect a booster effect. Positive diameters 5 mm were observed in 66% of the vaccinated individuals and 24% of the non-vaccinated subjects. Positive diameters 10 mm were observed in 51% of the vaccinated individuals and 19% of the non vaccinated ones. Positive diameters 15 mm were observed in 29% of the vaccinated subjects and in 13% of the non vaccinated ones. The differences were significant for all diameters. The positive predictive value of the test was 36.4% for a diameter 5 mm, 37.6% for diameter 10 mm and 44.8% for diameter 15 mm. The booster effect was detected in 25.8% of the vaccinated individuals who had tested negative at first. In vaccinated individuals, no guidelines can be established to guarantee that a positive reaction is due to infection by Mycobacterium tuberculosis infection, although the likelihood of infection (increased positive predictive value) increases with diameter. It is also impossible to fix a time limit. A second skin test is needed to detect a booster effect in all vaccinated individuals whose first test is negative.
Pan, Ying; Zhang, Yunshu; Peng, Yan; Zhao, Qinghua; Sun, Shucun
2015-01-01
Aquatic microcosm studies often increase either chamber height or base diameter (to increase water volume) to test spatial ecology theories such as “scale” effects on ecological processes, but it is unclear whether the increase of chamber height or base diameter have the same effect on the processes, i.e., whether the effect of the shape of three-dimensional spaces is significant. We orthogonally manipulated chamber height and base diameter and determined swimming activity, average swimming velocity and grazing rates of the cladocerans Daphnia magna and Moina micrura (on two algae Scenedesmus quadricauda and Chlorella vulgaris; leading to four aquatic algae-cladoceran systems in total) under different microcosm conditions. Across all the four aquatic systems, increasing chamber height at a given base diameter significantly decreased the duration and velocity of horizontal swimming, and it tended to increase the duration but decrease the velocity of vertical swimming. These collectively led to decreases in both average swimming velocity and grazing rate of the cladocerans in the tall chambers (at a given base diameter), in accordance with the positive relationship between average swimming velocity and grazing rate. In contrast, an increase of base diameter at a given chamber height showed contrasting effects on the above parameters. Consistently, at a given chamber volume increasing ratio of chamber height to base diameter decreased the average swimming velocity and grazing rate across all the aquatic systems. In general, increasing chamber depth and base diameter may exert contrasting effects on zooplankton behavior and thus phytoplankton-zooplankton interactions. We suggest that spatial shape plays an important role in determining ecological process and thus should be considered in a theoretical framework of spatial ecology and also the physical setting of aquatic microcosm experiments. PMID:26273836
Predicting the intrauterine fetal death of fetuses with cystic hygroma in early pregnancy.
Shimura, Mai; Ishikawa, Hiroshi; Nagase, Hiromi; Mochizuki, Akihiko; Sekiguchi, Futoshi; Koshimizu, Naho; Itai, Toshiyuki; Odagami, Mizuha
2018-01-11
We investigated whether it was possible to predict the prognosis of fetuses with cystic hygroma in early pregnancy based on the degree of neck thickening. We retrospectively analyzed 57 singleton pregnancies with fetuses with cystic hygroma who were examined before the 22nd week of pregnancy. The fetuses were categorized according to the outcome, structural abnormalities at birth, and chromosomal abnormalities. Here, we proposed a new sonographic predictor with which we assessed neck thickening by dividing the width of the neck thickening by the biparietal diameter, which is expressed as the cystic hygroma width/biparietal diameter ratio. The median cystic hygroma width/biparietal diameter ratio in the intrauterine fetal death group (0.51) was significantly higher than that in the live birth group (0.27). No significant difference in the median cystic hygroma width/biparietal diameter ratio was found between the structural abnormalities group at birth and the no structural abnormalities group, and no significant difference in the median cystic hygroma width/biparietal diameter ratio was found between the chromosomal abnormality group and the no chromosomal abnormality group. We used receiver operating characteristic analysis to evaluate the cystic hygroma width/biparietal diameter ratio to predict intrauterine fetal death. When the cystic hygroma width/biparietal diameter ratio cut-off value was 0.5, intrauterine fetal death could be predicted with a sensitivity of 52.9% and a specificity of 100%. It is possible to predict intrauterine fetal death in fetuses with cystic hygroma in early pregnancy if cystic hygroma width/biparietal diameter ratio is measured. However, even if cystic hygroma width/biparietal diameter ratio is measured, predicting the presence or absence of a structural abnormality at birth or a chromosomal abnormality is difficult. © 2018 Japanese Teratology Society.
Economics of ingot slicing with an internal diameter saw for low-cost solar cells
NASA Technical Reports Server (NTRS)
Daud, T.; Liu, J. K.; Fiegl, G.
1981-01-01
Slicing of silicon ingots using diamond impregnated internal diameter blade saws has been a standard technology of the semiconductor industry. This paper describes work on improvements to this technology for 10 cm diameter ingot slicing. Ingot rotation, dynamic blade edge control with feedback, mechanized blade dressing and development of thinner blades are the approaches tried. A comparison of the results for wafering with and without ingot rotation is also made. A sensitivity analysis of the major cost elements in wafering is performed for 10 cm diameter ingot and extended to the 15 cm diameter ingot case. Various parameter values such as machine cost, feed rate and consumable materials cost are identified both for single and multiple ingot slicing.
NASA Astrophysics Data System (ADS)
Zhang, Zhihao; Zhang, Chunxi; Xu, Xiaobin
2017-09-01
Small diameter (cladding and coating diameter of 100 and 135 μm) polarization maintaining photonic crystal fibres (SDPM-PCFs) possess many unique properties and are extremely suitable for applications in fibre optic gyroscopes. In this study, we have investigated and measured the stress characteristics of an SDPM-PCF using the finite-element method and a Mach-Zehnder interferometer, respectively. Our results reveal a radial and axial sensitivity of 0.315 ppm/N/m and 25.2 ppm per 1 × 105 N/m2, respectively, for the SDPM-PCF. These values are 40% smaller than the corresponding parameters of conventional small diameter (cladding and coating diameter of 80 and 135 μm) panda fibres.
Eustachian tube diameter: Is it associated with chronic otitis media development?
Paltura, Ceki; Can, Tuba Selçuk; Yilmaz, Behice Kaniye; Dinç, Mehmet Emre; Develioğlu, Ömer Necati; Külekçi, Mehmet
To evaluate the effect of ET diameter on Chronic Otitis Media (COM) pathogenesis. Retrospective. Patients with unilateral COM disease are included in the study. The connection between fibrocartilaginous and osseous segments of the Eustachian Tube (ET) on axial Computed Tomography (CT) images was defined and the diameter of this segment is measured. The measurements were carried out bilaterally and statistically compared. 154 (76 (49%) male, 78 (51%) female patients were diagnosed with unilateral COM and included in the study. The mean diameter of ET was 1947mm (Std. deviation±0.5247) for healthy ears and 1788mm (Std. deviation±0.5306) for diseased ears. The statistical analysis showed a significantly narrow ET diameter in diseased ear side (p<0.01). The dysfunction or anatomical anomalies of ET are correlated with COM. Measuring of the bony diameter of ET during routine Temporal CT examination is recommended for our colleagues. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tanaka, Hiroki; Wada, Yuji; Mizuno, Yosuke; Nakamura, Kentaro
2016-06-01
We investigated the fundamental aspects of droplet dispensing, which is an important procedure in the noncontact ultrasonic manipulation of droplets in air. A holed reflector was used to dispense a droplet from a 27.4 kHz standing-wave acoustic field to a well. First, the relationship between the hole diameter of the reflector and the acoustic radiation force acting on a levitated droplet was clarified by calculating the acoustic impedance of the point just above the hole. When the hole diameter was half of (or equal to) the acoustic wavelength λ, the acoustic radiation force was ∼80% (or 50%) of that without a hole. The maximal diameters of droplets levitated above the holes through flat and half-cylindrical reflectors were then experimentally investigated. For instance, with the half-cylindrical reflector, the maximal diameter was 5.0 mm for a hole diameter of 6.0 mm, and droplets were levitatable up to a hole diameter of 12 mm (∼λ).
Association of deep venous thrombosis with calf vein diameter in acute hemorrhagic stroke.
Ogata, Toshiyasu; Yasaka, Masahiro; Wakugawa, Yoshiyuki; Kitazono, Takanari; Okada, Yasushi
2013-10-01
We investigated the association between the development of deep venous thrombosis (DVT) and calf vein diameter in patients with acute hemorrhagic stroke. We measured the maximum diameter of paralytic side posttibial veins (PTVs) and peroneal veins (PVs) in 49 patients with intracerebral hemorrhage on admission and at 2 weeks after stroke onset by ultrasonography. We also examined for the presence or absence of DVT, and then analyzed the association of DVT with the maximum vein diameter. At 2 weeks after stroke, DVTs were detected in PTVs in 7 patients and in PVs in 6 patients. The maximum calf vein diameters at 2 weeks were significantly greater in patients with DVT compared with those without DVT (PTV, P = .033; PV, P = .015). Although calf vein diameter at admission did not influence the future incidence of DVT in patients with intracerebral hemorrhage, the presence of DVT was associated with calf vein dilatation. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Lunar crater volumes - Interpretation by models of impact cratering and upper crustal structure
NASA Technical Reports Server (NTRS)
Croft, S. K.
1978-01-01
Lunar crater volumes can be divided by size into two general classes with distinctly different functional dependence on diameter. Craters smaller than approximately 12 km in diameter are morphologically simple and increase in volume as the cube of the diameter, while craters larger than about 20 km are complex and increase in volume at a significantly lower rate implying shallowing. Ejecta and interior volumes are not identical and their ratio, Schroeters Ratio (SR), increases from about 0.5 for simple craters to about 1.5 for complex craters. The excess of ejecta volume causing the increase, can be accounted for by a discontinuity in lunar crust porosity at 1.5-2 km depth. The diameter range of significant increase in SR corresponds with the diameter range of transition from simple to complex crater morphology. This observation, combined with theoretical rebound calculation, indicates control of the transition diameter by the porosity structure of the upper crust.
Pluto and Charon - the dance goes on
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beatty, J.K.
1987-09-01
Various methods for estimating the diameters of Pluto and Charon are discussed. The application of speckle interferometry, the timing of occultations, and the monitoring of Charon and Pluto rotations to calculate the diameter of the planet and its satellite are described. Walker (1980) estimated Charon's diameter as greater than 1200 km using the occultated star method; the speckle interferometry estimates of Baier and Weigelt (1983) are between 2710-3460 km for Pluto and between 1050-1520 km for Charon; and using the mutual events method Dunbar and Tedesco (1986) estimated the diameter of Pluto as 2300 + or - 100 km andmore » of Charon as 1500 + or - 100 km. The use of IRAS data combined with visual brightness to estimate planet and satellite diameters is examined; Tedesco et al. (1987) estimated Pluto's diameter as 2200 + or - 150 km and Charon's as 1300 + or - 150 km, and Aumann and Walker (1987) obtained estimates of 2360 km for Pluto and 1534 km for Charon. The compositions of Pluto's and Charon's atmospheres are analyzed.« less
Memory, emotion, and pupil diameter: Repetition of natural scenes.
Bradley, Margaret M; Lang, Peter J
2015-09-01
Recent studies have suggested that pupil diameter, like the "old-new" ERP, may be a measure of memory. Because the amplitude of the old-new ERP is enhanced for items encoded in the context of repetitions that are distributed (spaced), compared to massed (contiguous), we investigated whether pupil diameter is similarly sensitive to repetition. Emotional and neutral pictures of natural scenes were viewed once or repeated with massed (contiguous) or distributed (spaced) repetition during incidental free viewing and then tested on an explicit recognition test. Although an old-new difference in pupil diameter was found during successful recognition, pupil diameter was not enhanced for distributed, compared to massed, repetitions during either recognition or initial free viewing. Moreover, whereas a significant old-new difference was found for erotic scenes that had been seen only once during encoding, this difference was absent when erotic scenes were repeated. Taken together, the data suggest that pupil diameter is not a straightforward index of prior occurrence for natural scenes. © 2015 Society for Psychophysiological Research.
Sell, Scott; Barnes, Catherine; Simpson, David; Bowlin, Gary
2008-04-01
The purpose of this study was to construct a flowmeter that could accurately measure the hydraulic permeability of electrospun fibrinogen scaffolds, providing insight into the transport properties of electrospun scaffolds while making the measurement of their topographical features (fiber diameter and pore size) more accurate. Three different concentrations of fibrinogen were used (100, 120, and 150 mg/mL) to create scaffolds with three different fiber diameters and pore sizes. The fiber diameters and pore sizes of the electrospun scaffolds were first analyzed with scanning electron microscopy and image analysis software. The permeability of each scaffold was measured with the flowmeter and used to calculate permeability-based fiber diameters and pore sizes, which were compared to values obtained through image analysis. Permeability measurement revealed scaffold permeability to increase with fibrinogen concentration, much like average fiber diameter and pore size. Comparison between the two measurement methods demonstrated the efficacy of the flowmeter as a way to measure scaffold features. Copyright 2007 Wiley Periodicals, Inc.
The effect of nozzle-exit-channel shape on resultant fiber diameter in melt-electrospinning
NASA Astrophysics Data System (ADS)
Esmaeilirad, Ahmad; Ko, Junghyuk; Rukosuyev, Maxym V.; Lee, Jason K.; Lee, Patrick C.; Jun, Martin B. G.
2017-01-01
In recent decades, electrospinning using a molten poly (ε-caprolactone) resin has gained attention for creating fibrous tissue scaffolds. The topography and diameter control of such electrospun microfibers is an important issue for their different applications in tissue engineering. Charge density, initial nozzle-exit-channel cross-sectional area, nozzle to collector distance, viscosity, and processing temperature are the most important input parameters that affect the final electrospun fiber diameters. In this paper we will show that the effect of nozzle-exit-channel shape is as important as the other effective parameters in a resultant fiber diameter. However, to the best of our knowledge, the effect of nozzle-exit-channel shapes on a resultant fiber diameter have not been studied before. Comparing rectangular and circular nozzles with almost the same exit-channel cross-sectional areas in a similar processing condition showed that using a rectangular nozzle resulted in decreasing final fiber diameter up to 50%. Furthermore, the effect of processing temperature on the final fiber topography was investigated.
Wang, Liang; Yuan, Jin; Jiang, Hong; Yan, Wentao; Cintrón-Colón, Hector R; Perez, Victor L; DeBuc, Delia C; Feuer, William J; Wang, Jianhua
2016-03-01
This study determined (1) how many vessels (i.e., the vessel sampling) are needed to reliably characterize the bulbar conjunctival microvasculature and (2) if characteristic information can be obtained from the distribution histogram of the blood flow velocity and vessel diameter. Functional slitlamp biomicroscope was used to image hundreds of venules per subject. The bulbar conjunctiva in five healthy human subjects was imaged on six different locations in the temporal bulbar conjunctiva. The histograms of the diameter and velocity were plotted to examine whether the distribution was normal. Standard errors were calculated from the standard deviation and vessel sample size. The ratio of the standard error of the mean over the population mean was used to determine the sample size cutoff. The velocity was plotted as a function of the vessel diameter to display the distribution of the diameter and velocity. The results showed that the sampling size was approximately 15 vessels, which generated a standard error equivalent to 15% of the population mean from the total vessel population. The distributions of the diameter and velocity were not only unimodal, but also somewhat positively skewed and not normal. The blood flow velocity was related to the vessel diameter (r=0.23, P<0.05). This was the first study to determine the sampling size of the vessels and the distribution histogram of the blood flow velocity and vessel diameter, which may lead to a better understanding of the human microvascular system of the bulbar conjunctiva.
Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Nakano, Masahiro; Kubota, Yasuaki; Maeda, Sunaho; Ohtakara, Kazuhiro; Deguchi, Takashi; Hoshi, Hiroaki
2007-08-01
No studies have yet evaluated the effects of a dosimetric analysis for different urethral volumes. We therefore evaluated the effects of a dosimetric analysis to determine the different urethral volumes. This study was based on computed tomography/magnetic resonance imaging (CT/MRI) combined findings in 30 patients who had undergone prostate brachytherapy. Postimplant CT/MRI scans were performed 30 days after the implant. The urethra was contoured based on its diameter (8, 6, 4, 2, and 0 mm). The total urethral volume-in cubic centimeters [UrV150/200(cc)] and percent (UrV150%/200%), of the urethra receiving 150% or 200% of the prescribed dose-and the doses (UrD90/30/5) in Grays to 90%, 30%, and 5% of the urethral volume were measured based on the urethral diameters. The UrV150(cc) and UrD30 were statistically different between the of 8-, 6-, 4-, 2-, and 0-mm diameters, whereas the UrD5 was statistically different only between the 8-, 6-, and 4-mm diameters. Especially for UrD5, there was an approximately 40-Gy difference between the mean values for the 8- and 0-mm diameters. We recommend that the urethra should be contoured as a 4- to 6-mm diameter circle or one side of a triangle of 5-7 mm. By standardizing the urethral diameter, the urethral dose will be less affected by the total urethral volume.
Leigh-Smith, Simon; Stevenson, Richard; Watt, Martin; Watt, Ian; McFadyen, Angus; Grant, Stan
2004-01-01
To determine whether pan diameter influences carbon monoxide (CO) concentration during heating of water to boiling point with a camping stove. The hypothesis was that increasing pan diameter increases CO concentration because of greater flame dispersal and a larger flame. This was a randomized, prospective study. A Coleman Dual Fuel 533 stove was used to heat pans of water to boiling point, with CO concentration monitored every 30 seconds for 5 minutes. The stove was inside a partially ventilated 200-L cardboard box model that was inside an environmental chamber at -6 degrees C. Water temperature, water volume, and flame characteristics were all standardized. Ten trials were performed for each of 2 pan diameters (base diameters of 165 mm [small] and 220 mm [large]). There was a significant difference (P = .002) between the pans for CO levels at each measurement interval from 60 seconds onward. These differences were markedly larger after 90 seconds, with a mean difference of 185 ppm (95% CI 115, 276 ppm) for all the results from 120 seconds onwards. This study has shown that there is significantly higher CO production with a large-diameter pan compared with a small-diameter pan. These findings were evident by using a camping stove to heat water to boiling point when a maximum blue flame was present throughout. Thus, in enclosed environments it is recommended that small-diameter pans be used in an attempt to prevent high CO levels.
NASA Astrophysics Data System (ADS)
Golombek, M. P.; Haldemann, A. F. C.; Forsberg-Taylor, N. K.; DiMaggio, E. N.; Schroeder, R. D.; Jakosky, B. M.; Mellon, M. T.; Matijevic, J. R.
2003-10-01
The cumulative fractional area covered by rocks versus diameter measured at the Pathfinder site was predicted by a rock distribution model that follows simple exponential functions that approach the total measured rock abundance (19%), with a steep decrease in rocks with increasing diameter. The distribution of rocks >1.5 m diameter visible in rare boulder fields also follows this steep decrease with increasing diameter. The effective thermal inertia of rock populations calculated from a simple empirical model of the effective inertia of rocks versus diameter shows that most natural rock populations have cumulative effective thermal inertias of 1700-2100 J m-2 s-0.5 K-1 and are consistent with the model rock distributions applied to total rock abundance estimates. The Mars Exploration Rover (MER) airbags have been successfully tested against extreme rock distributions with a higher percentage of potentially hazardous triangular buried rocks than observed at the Pathfinder and Viking landing sites. The probability of the lander impacting a >1 m diameter rock in the first 2 bounces is <3% and <5% for the Meridiani and Gusev landing sites, respectively, and is <0.14% and <0.03% for rocks >1.5 m and >2 m diameter, respectively. Finally, the model rock size-frequency distributions indicate that rocks >0.1 m and >0.3 m in diameter, large enough to place contact sensor instruments against and abrade, respectively, should be plentiful within a single sol's drive at the Meridiani and Gusev landing sites.
Turkbey, Evrim B.; Jain, Aditya; Johnson, Craig; Redheuil, Alban; Arai, Andrew E.; Gomes, Antoinette S.; Carr, James; Hundley, W. Gregory; Teixido-Tura, Gisela; Eng, John; Lima, Joao A.C.; Bluemke, David A.
2013-01-01
PURPOSE To determine the normal size and wall thickness of the ascending thoracic aorta (AA) and its relationship with cardiovascular risk factors in a large population-based study. MATERIALS AND METHODS The mean AA luminal diameter was measured in 3573 Multi-Ethnic Study of Atherosclerosis (MESA) participants (age: 45–84 years), using gradient echo phase contrast cine MRI. Multiple linear regression models were used to evaluate the associations between risk factors and AA diameter. The median and upper normal limit (95th percentile) was defined in a “healthy” subgroup as well as AA wall thickness. RESULTS The upper limits of body surface area indexed AA luminal diameter for age categories of 45–54, 55–64, 65–74, and 75–84 years are 21, 22, 22, and 28 mm/m2 in women and 20, 21, 22, 23 mm/m2 in men, respectively. The mean AA wall thickness was 2.8 mm. Age, gender and body surface area were major determinants of AA luminal diameter (~+1 mm/10 years; ~+1.9 mm in men than women; ~+1 mm/ 0.23 m2; p<0.001). The AA diameter in hypertensive subjects was +0.9 mm larger than in normotensives (p<0.001). CONCLUSION AA diameter increases gradually with aging for both genders, among all race/ethnicities. Normal value of AA diameter is provided. PMID:23681649
Relationship of stump diameter to d.b.h. for sugar maple in the northeast
Frederick E. Hampf
1955-01-01
This is the second report on a series of studies (2) made show the relationship of stump diameter to diameter breast high (d.b.h.) for commercially important tree species in the Northeast. This report is for sugar maple (Acer saccharum).
Relationship of stump diameter to d.b.h. for white oak in the Northeast
Frederick E. Hampf
1957-01-01
This is the eighth report on a series of studies to show the relationship of stump diameter to diameter breast high (d.b.h.) for commercially important tree species in the Northeast. This report is for white oak (Quercus alba).
Relationship of stump diameter to d.b.h. for pitch pine in the northeast
Frederick E. Hampf
1957-01-01
This is the seventh report on a series of studies to show the relationship of stump diameter to diameter breast high (d. b. h.) for commercially important tree species in the Northeast. This report is for pitch pine (Pinus rigida).
Relationship of stump diameter to d. b. h. for yellow-poplar in the Northeast
Frederick E. Hampf
1955-01-01
This is the sixth report on a series of studies to show the relationship of stump diameter to diameter breast high (d. b. h.) for commercially important tree species in the Northeast. This report is for yellow-poplar (Lirodendron tulipifera).
Relationship of stump diameter to d.b.h. for yellow birch in the Northeast
Frederick E. Hampf
1955-01-01
This is the fourth report on a series of studies to show the relationship of stump diameter to diameter breast high (d.b.h.) for commercially important tree species in the Northeast. This report is for yellow birch (Betula alleghaniensis).
Physical properties of lunar craters
NASA Astrophysics Data System (ADS)
Joshi, Maitri P.; Bhatt, Kushal P.; Jain, Rajmal
2017-02-01
The surface of the Moon is highly cratered due to impacts of meteorites, asteroids, comets and other celestial objects. The origin, size, structure, age and composition vary among craters. We study a total of 339 craters observed by the Lunar Reconnaissance Orbiter Camera (LROC). Out of these 339 craters, 214 craters are known (named craters included in the IAU Gazetteer of Planetary Nomenclature) and 125 craters are unknown (craters that are not named and objects that are absent in the IAU Gazetteer). We employ images taken by LROC at the North and South Poles and near side of the Moon. We report for the first time the study of unknown craters, while we also review the study of known craters conducted earlier by previous researchers. Our study is focused on measurements of diameter, depth, latitude and longitude of each crater for both known and unknown craters. The diameter measurements are based on considering the Moon to be a spherical body. The LROC website also provides a plot which enables us to measure the depth and diameter. We found that out of 214 known craters, 161 craters follow a linear relationship between depth (d) and diameter (D), but 53 craters do not follow this linear relationship. We study physical dimensions of these 53 craters and found that either the depth does not change significantly with diameter or the depths are extremely high relative to diameter (conical). Similarly, out of 125 unknown craters, 78 craters follow the linear relationship between depth (d) and diameter (D) but 47 craters do not follow the linear relationship. We propose that the craters following the scaling law of depth and diameter, also popularly known as the linear relationship between d and D, are formed by the impact of meteorites having heavy metals with larger dimension, while those with larger diameter but less depth are formed by meteorites/celestial objects having low density material but larger diameter. The craters with very high depth and with very small diameter are perhaps formed by the impact of meteorites that have very high density but small diameter with a conical shape. Based on analysis of the data selected for the current investigation, we further found that out of 339 craters, 100 (29.5%) craters exist near the equator, 131 (38.6%) are in the northern hemisphere and 108 (31.80%) are in the southern hemisphere. This suggests the Moon is heavily cratered at higher latitudes and near the equatorial zone.
Code of Federal Regulations, 2011 CFR
2011-01-01
... defect, shall be considered as damage: (a) Bacterial spot, when cracked, or when aggregating more than 3/8 inch in diameter; (b) Scab spots, when cracked, or when aggregating more than 3/8 inch in diameter... diameter; (f) Split pit, when causing any unhealed crack, or when causing any crack which is readily...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2010 CFR
2010-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2013 CFR
2013-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2011 CFR
2011-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2012 CFR
2012-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
29 CFR 1910.243 - Guarding of portable powered tools.
Code of Federal Regulations, 2014 CFR
2014-07-01
... circular saws. (i) All portable, power-driven circular saws having a blade diameter greater than 2 in.... (2) Switches and controls. (i) All hand-held powered circular saws having a blade diameter greater... diameter, belt sanders, reciprocating saws, saber, scroll, and jig saws with blade shanks greater than a...
Jay R. Law; Craig G. Lorimer
1989-01-01
Maintaining uneven-aged stands involves cutting trees from a range of diameter classes in such a way that the residual stand has a balanced, steeply descending diameter distribution curve (fig. 1). The objective is to distribute trees by diameter classes so that over time the stand contains trees of different ages and sizes.
1975-12-01
FUNNEL DIAMETER 250 DIA FUNNEL DIAMETER, Df SHOWN IN LIST 375 FUNNEL DIAMETER Df . 043 ,060 .173 .044 .062 .175 .045 .063 .176 .046...Physical Dimensions Nom . Size (mil) Fiber Count V (mi 1) d (mil) [ (nr ) 1) 1 (m- Df 1) 46 285 41 .58 2.463 45 79 46 .71 ^/2x46 570 58
Relationship of stump diameter to d.b.h. for American beech in the Northeast
Frederick E. Hampf
1955-01-01
This is the third report on a series of studies (2, 3) made to show the relationship of stump diameter to diameter breast high (d. b. h.) for commercially important tree species in the Northeast. This report is for American beech (Fagus grandifolia).
Relationship of stump diameter to d.b.h. for northern red oak in the Northeast
Frederick E. Hampf
1955-01-01
This is the fifth report on a series of studies to show the relationship of stump diameter to diameter breast high (d.b.h.) for commercially important tree species in the Northeast. This report is for northern red oak (Quercus rubra).
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-16
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-929] Small Diameter Graphite... (Department) determines that imports from the People's Republic of China (PRC) of graphite electrodes... Act of 1930, as amended (the Act).\\1\\ \\1\\ See Antidumping Duty Order: Small Diameter Graphite...
NASA Technical Reports Server (NTRS)
Fastig, Shlomo; Deoung, Russell J.
1998-01-01
Acrylic plastic Fresnel lenses are very light and can have large diameters. Such lenses could be used in lidar telescope receivers if the focal spot is not too large or distorted. This research effort characterizes the focal spot diameter produced by a Fresnel lens with a diameter of 30.5 cm (12 in.). It was found that the focal spot diameter varied from 1.2 mm at 750 nm to 1.6 mm at 910 nm. The focal spot was irregular and not easily described by a Gaussian profile.
Zhu, Ming; Wang, Yao-Ting; Sun, Yi-Zhi; Zhang, Lijian; Ding, Wei
2018-02-01
A convenient method using a commercially available ruled grating for precise and overall diameter measurement of optical nanofibers (ONFs) is presented. We form a composite Bragg reflector with a micronscale period by dissolving aluminum coating, slicing the grating along ruling lines, and mounting it on an ONF. The resonant wavelengths of high-order Bragg reflections possess fiber diameter dependence, enabling nondestructive measurement of the ONF diameter profile. This method provides an easy and economic diagnostic tool for wide varieties of ONF-based applications.
NASA Technical Reports Server (NTRS)
Barlow, Nadine G.; Bradley, Tracy L.
1990-01-01
An effort is made to establish the ability of a correlation between crater morphology and latitude, diameter, and terrain, to discriminate among the effects of impact energy, atmosphere, and subsurface volatiles in 3819 larger-than-8 km diameter craters distributed over the Martian surface. It is noted that changes in ejecta and interior morphology correlate with increases in crater diameter, and that while many of the interior structures exhibit distributions interpretable as terrain-dependent, central peak and peak ring interior morphologies exhibit minimal relationships with planetary properties.
Application of small-diameter FBG sensors for detection of damages in composites
NASA Astrophysics Data System (ADS)
Okabe, Yoji; Mizutani, Tadahito; Yashiro, Shigeki; Takeda, Nobuo
2001-08-01
Small-diameter fiber Bragg grating (FBG) sensors have been developed by Hitachi Cable Ltd. and the authors. Since the outside diameter of polyimide coating is 52 micrometers , embedding of the sensors into carbon fiber reinforced plastic (CFRP) composites prepregs of 125 micrometers in thickness does not deteriorate the mechanical properties of the composite laminates. In this research, the small-diameter FBG sensor was applied for the detection of transverse cracks in CFRP composites. The FBG sensor was embedded in 0 degree(s) ply of a CFRP cross-ply laminate.
Dawn Framing Camera: Morphology and morphometry of impact craters on Ceres
NASA Astrophysics Data System (ADS)
Platz, T.; A; Nathues; Schäfer, M.; Hoffmann, M.; Kneissl, T.; Schmedemann, N.; Vincent, J.-B.; Büttner, I.; Gutierrez-Marques, P.; Ripken, J.; Russell, C. T.; Schäfer, T.; Thangjam, G. S.
2015-10-01
In the first approach images of Ceres we tried to discern the simple-to-complex transition diameter of impact craters. Limited by spatial resolution we found the smallest complex crater without central peak development to be around 21.4 km in diameter. Hence, the transition diameter is expected to be between 21.4 km and 10.6 km, the predicted transition diameter for an icy target. It appears likely that either Ceres' surface material contains a rocky component or has a laterally inhomogeneous composition ranging from icy to ice-rocky
Annular ring zoom system using two positive axicons
NASA Astrophysics Data System (ADS)
Dickey, Fred M.; Conner, Jacob D.
2011-10-01
The production of an annular ring of light with a variable diameter has applications in laser material processing and machining, particle manipulation, and corneal surgery. This can readily be accomplished using a positive and negative axicon pair. However, negative axicons are very expensive and difficult to obtain with small diameters. In this paper, we present a design of an annular ring zoom system using two positive axicons. One axicon is placed a distance before a primary lens that is greater than some prescribed minimum, and the second axicon is placed after the primary lens. The position of the second axicon determines the ring diameter. The ring diameter can be zoomed from some maximum design size to a zero diameter ring (spot). Experimental results from a developmental system will be presented.
NASA Technical Reports Server (NTRS)
Indoe, William
2012-01-01
A gas-charging plug can be easily analyzed for random vibration. The design features two steeped O-rings in a radial configuration at two different diameters, with a 0.050-in. (.1.3-mm) diameter through-hole between the two O-rings. In the charging state, the top O-ring is engaged and sealing. The bottom O-ring outer diameter is not squeezed, and allows air to flow by it into the tank. The inner diameter is stretched to plug the gland diameter, and is restrained by the O-ring groove. The charging port bushing provides mechanical stop to restrain the plug during gas charge removal. It also prevents the plug from becoming a projectile when removing gas charge from the accumulator. The plug can easily be verified after installation to ensure leakage requirements are met.
Diameter-Constrained Steiner Tree
NASA Astrophysics Data System (ADS)
Ding, Wei; Lin, Guohui; Xue, Guoliang
Given an edge-weighted undirected graph G = (V,E,c,w), where each edge e ∈ E has a cost c(e) and a weight w(e), a set S ⊆ V of terminals and a positive constant D 0, we seek a minimum cost Steiner tree where all terminals appear as leaves and its diameter is bounded by D 0. Note that the diameter of a tree represents the maximum weight of path connecting two different leaves in the tree. Such problem is called the minimum cost diameter-constrained Steiner tree problem. This problem is NP-hard even when the topology of Steiner tree is fixed. In present paper we focus on this restricted version and present a fully polynomial time approximation scheme (FPTAS) for computing a minimum cost diameter-constrained Steiner tree under a fixed topology.
The Attributes of a Variable-Diameter Rotor System Applied to Civil Tiltrotor Aircraft
NASA Technical Reports Server (NTRS)
Brender, Scott; Mark, Hans; Aguilera, Frank
1996-01-01
The attributes of a variable diameter rotor concept applied to civil tiltrotor aircraft are investigated using the V/STOL aircraft sizing and performance computer program (VASCOMP). To begin, civil tiltrotor viability issues that motivate advanced rotor designs are discussed. Current work on the variable diameter rotor and a theoretical basis for the advantages of the rotor system are presented. The size and performance of variable diameter and conventional tiltrotor designs for the same baseline mission are then calculated using a modified NASA Ames version of VASCOMP. The aircraft are compared based on gross weight, fuel required, engine size, and autorotative performance for various hover disk loading values. Conclusions about the viability of the resulting designs are presented and a program for further variable diameter rotor research is recommended.
The entrainment rate for a row of turbulent jets. M.S. Thesis Final Report
NASA Technical Reports Server (NTRS)
Gordon, Eliott B.; Greber, Isaac
1990-01-01
Entrainment rates for a row of isothermal circular air jets issuing into a quiescent environment are found by integrating velocity distributions measured by a linearized hot-wire anemometer. Jet spacing to jet diameter ratios of 2.5, 5, 10, and 20 are studied at jet Reynold's numbers ranging from 5110 to 12070. Velocity distributions are determined at regular downstream intervals at axial distances equal to 16.4 to 164 jet diameters from the jet source. The entrainment rates for the four spacing configurations vary monotonically with increasing spacing/diameter between the limiting case of the slot jet entrainment rate (where the jet spacing to diameter ratio is zero) and the circular jet entrainment rate (in which the spacing to diameter ratio is infinity).
Experimental study of cryogen spray properties for application in dermatologic laser surgery.
Aguilar, Guillermo; Majaron, Boris; Karapetian, Emil; Lavernia, Enrique J; Nelson, J Stuart
2003-07-01
Cryogenic sprays are used for cooling human skin during laser dermatologic surgery. In this paper, six straight-tube nozzles are characterized by photographs of cryogenic spray shapes, as well as measurements of average droplet diameter, velocity, and temperature. A single-droplet evaporation model to predict average spray droplet diameter and temperature is tested using the experimental data presented here. The results show two distinct spray patterns--sprays for 1.4-mm-diameter nozzles (wide nozzles) show significantly larger average droplet diameters and higher temperatures as a function of distance from the nozzle compared with those for 0.5-0.8-mm-diameter nozzles (narrow nozzles). These results complement and support previously reported studies, indicating that wide nozzles induce more efficient heat extraction than the narrow nozzles.
NASA Technical Reports Server (NTRS)
Hippensteele, S. A.; Cochran, R. P.
1980-01-01
The effects of two design parameters, electrode diameter and hole angle, and two machine parameters, electrode current and current-on time, on air flow rates through small-diameter (0.257 to 0.462 mm) electric-discharge-machined holes were measured. The holes were machined individually in rows of 14 each through 1.6 mm thick IN-100 strips. The data showed linear increase in air flow rate with increases in electrode cross sectional area and current-on time and little change with changes in hole angle and electrode current. The average flow-rate deviation (from the mean flow rate for a given row) decreased linearly with electrode diameter and increased with hole angle. Burn time and finished hole diameter were also measured.
Suitable pitch difference to realize anti-loosening performance for various bolts-nuts diameter
NASA Astrophysics Data System (ADS)
Kubo, S.; Tateishi, K.; Noda, N.-A.; Sano, Y.; Takase, Y.; Honda, K.
2018-06-01
In bolt-nut connection, the anti-loosening performance and high fatigue strength are always required with low cost to ensure the connected structure’s safety. In the previous study, a suitable pitch difference between the bolt-nut was obtained as α = 33 μm for M16 JIS bolt- nut through loosening experiment and FEM simulation for tightening process. However, other bolt-nut diameters have not been considered yet. In this paper, therefore, suitable pitch difference is considered for various diameters to realize anti-loosening performance. Since bolt-nut thread geometries are different depending on the diameter, they are expressed as approximate formula. Then, loosening force and anti-loosening force are considered by varying the diameter. Finally, suitable pitch difference {α }minsuit< α < {α }maxsuit was determined from mechanical condition.
NASA Astrophysics Data System (ADS)
Schaub, Scott A.; Naqwi, Amir A.; Harding, Foster L.
1998-01-01
We present fundamental studies examining the design of a phase /Doppler laser light-scattering system applicable to on-line measurements of small-diameter ( <15 m) fibers during fiberglass manufacturing. We first discuss off-line diameter measurement techniques currently used in the fiberglass industry and outline the limitations and problems associated with these methods. For the phase /Doppler design study we have developed a theoretical computer model for the response of the measurement system to cylindrical fibers, which is based on electromagnetic scattering theory. The model, valid for arbitrary fiber diameters and hardware configurations, generates simulated detector output as a function of time for a finite absorbing, cylindrical fiber oriented perpendicular to the two incident laser beams. Results of experimental measurements are presented, confirming predictions of the theoretical model. Parametric studies have also been conducted using the computer model to identify experimental arrangements that provide linear phase -diameter relationships for small-diameter fibers, within the measurement constraints imposed by the fiberglass production environment. The effect of variations in optical properties of the glass as well as fiber orientation effects are discussed. Through this research we have identified phase /Doppler arrangements that we expect to have future applications in the fiberglass industry for on-line diameter monitoring and process control.
Schaub, S A; Naqwi, A A; Harding, F L
1998-01-20
We present fundamental studies examining the design of a phase/Doppler laser light-scattering system applicable to on-line measurements of small-diameter (<15 mum) fibers during fiberglass manufacturing. We first discuss off-line diameter measurement techniques currently used in the fiberglass industry and outline the limitations and problems associated with these methods. For the phase/Doppler design study we have developed a theoretical computer model for the response of the measurement system to cylindrical fibers, which is based on electromagnetic scattering theory. The model, valid for arbitrary fiber diameters and hardware configurations, generates simulated detector output as a function of time for a finite absorbing, cylindrical fiber oriented perpendicular to the two incident laser beams. Results of experimental measurements are presented, confirming predictions of the theoretical model. Parametric studies have also been conducted using the computer model to identify experimental arrangements that provide linear phase-diameter relationships for small-diameter fibers, within the measurement constraints imposed by the fiberglass production environment. The effect of variations in optical properties of the glass as well as fiber orientation effects are discussed. Through this research we have identified phase/Doppler arrangements that we expect to have future applications in the fiberglass industry for on-line diameter monitoring and process control.
Age, ocular magnification, and circumpapillary retinal nerve fiber layer thickness
NASA Astrophysics Data System (ADS)
Wang, Mengyu; Elze, Tobias; Li, Dian; Baniasadi, Neda; Wirkner, Kerstin; Kirsten, Toralf; Thiery, Joachim; Loeffler, Markus; Engel, Christoph; Rauscher, Franziska G.
2017-12-01
Optical coherence tomography (OCT) manufacturers graphically present circumpapillary retinal nerve fiber layer thickness (cpRNFLT) together with normative limits to support clinicians in diagnosing ophthalmic diseases. The impact of age on cpRNFLT is typically implemented by linear models. cpRNFLT is strongly location-specific, whereas previously published norms are typically restricted to coarse sectors and based on small populations. Furthermore, OCT devices neglect impacts of lens or eye size on the diameter of the cpRNFLT scan circle so that the diameter substantially varies over different eyes. We investigate the impact of age and scan diameter reported by Spectralis spectral-domain OCT on cpRNFLT in 5646 subjects with healthy eyes. We provide cpRNFLT by age and diameter at 768 angular locations. Age/diameter were significantly related to cpRNFLT on 89%/92% of the circle, respectively (pointwise linear regression), and to shifts in cpRNFLT peak locations. For subjects from age 42.1 onward but not below, increasing age significantly decreased scan diameter (r=-0.28, p<0.001), which suggests that pathological cpRNFLT thinning over time may be underestimated in elderly compared to younger subjects, as scan diameter decrease correlated with cpRNFLT increase. Our detailed numerical results may help to generate various correction models to improve diagnosing and monitoring optic neuropathies.
A study of the effect of pregnancy on muscle fibers of the rectus abdominis muscle of the rat.
Martin, W D
1979-11-01
Samples of the rectus abdominis muscle were taken from Sprague-Dawley rats at 0, 3, 6, 6, 12, 15, 18, and 21 days of pregnancy, and at 1, 3, 6, 9, 12, and 15 days of postpartum. Sections were incubated for actomyosin adenosine triphosphatase activity following preincubation at a basic pH. Muscle fibers within a unit area of each sample were identified as to fiber type according to their enzyme activity, and the population of each type counted. The proportion of each fiber type was calculated and the diameter of 24 fibers of each type measured. No changes were noted in the muscle fiber proportions through the course of the experiment. Differential changes in muscle fiber diameters were noted in each of the three muscle fiber types. Slow oxidative fibers underwent an increase in diameter through the last half of pregnancy. The diameter was further increased as stretch of the muscle was released after birth, and did not decrease in the postpartum period. Fast glycolytic fibers decreased in diameter during the last half of pregnancy, but returned to the prepregnancy diameter in the first postpartum day. The diameter of the fast oxidative glycolytic fibers remained unchanged through the course of pregnacy and in the postpartum period.
NASA Astrophysics Data System (ADS)
Pao, W.; Hon, L.; Saieed, A.; Ban, S.
2017-10-01
A smaller diameter conduit pointing at 12 o’clock position is typically hot-tapped to a horizontal laying production header in offshore platform to tap produced gas for downstream process train. This geometric feature is commonly known as T-junction. The nature of multiphase fluid splitting at the T-junction is a major operational challenge due to unpredictable production environment. Often, excessive liquid carryover occurs in the T-junction, leading to complete platform trip and halt production. This is because the downstream process train is not designed to handle excessive liquid. The objective of this research is to quantify the effect of different diameter ratio on phase separation efficiency in T-junction. The liquid carryover is modelled as two-phase air-water flow using Eulerian Mixture Model coupled with Volume of Fluid Method to mimic the slug flow in the main pipe. The focus in this paper is 0.0254 m (1 inch) diameter horizontal main arm and vertical branch arm with diameter ratio of 1.0, 0.5 and 0.3. The present research narrowed the investigation to only slug flow regime using Baker’s map as reference. The investigation found that, contrary to common believe, smaller diameter ratio T-junction perform worse than larger diameter ratio T-junction.
Ultra-efficient Engine Diameter Study
NASA Technical Reports Server (NTRS)
Daggett, David L.; Brown, Stephen T.; Kawai, Ron T.
2003-01-01
Engine fan diameter and Bypass Ratio (BPR) optimization studies have been conducted since the beginning of the turbofan age with the recognition that reducing the engine core jet velocity and increasing fan mass flow rate generally increases propulsive efficiency. However, performance tradeoffs limit the amount of fan flow achievable without reducing airplane efficiency. This study identifies the optimum engine fan diameter and BPR, given the advanced Ultra-Efficient Engine Technology (UEET) powerplant efficiencies, for use on an advanced subsonic airframe. Engine diameter studies have historically focused on specific engine size options, and were limited by existing technology and transportation infrastructure (e.g., ability to fit bare engines through aircraft doors and into cargo holds). This study is unique in defining the optimum fan diameter and drivers for future 2015 (UEET) powerplants while not limiting engine fan diameter by external constraints. This report follows on to a study identifying the system integration issues of UEET engines. This Engine Diameter study was managed by Boeing Phantom Works, Seattle, Washington through the NASA Glenn Revolutionary Aero Space Engine Research (RASER) contract under task order 10. Boeing Phantom Works, Huntington Beach, completed the engine/airplane sizing optimization, while the Boeing Commercial Airplane group (BCA) provided design oversight. A separate subcontract to support the overall project was issued to Tuskegee University.
Role of surfactants in carbon nanotubes density gradient separation.
Carvalho, Elton J F; dos Santos, Maria Cristina
2010-02-23
Several strategies aimed at sorting single-walled carbon nanotubes (SWNT) by diameter and/or electronic structure have been developed in recent years. A nondestructive sorting method was recently proposed in which nanotube bundles are dispersed in water-surfactant solutions and submitted to ultracentrifugation in a density gradient. By this method, SWNTs of different diameters are distributed according to their densities along the centrifuge tube. A mixture of two anionic amphiphiles, namely sodium dodecylsulfate (SDS) and sodium cholate (SC), presented the best performance in discriminating nanotubes by diameter. We present molecular dynamics studies of the water-surfactant-SWNT system. The simulations revealed one aspect of the discriminating power of surfactants: they can actually be attracted toward the interior of the nanotube cage. The binding energies of SDS and SC on the outer nanotube surface are very similar and depend weakly on diameter. The binding inside the tubes, on the contrary, is strongly diameter dependent: SDS fits best inside tubes with diameters ranging from 8 to 9 A, while SC is best accommodated in larger tubes, with diameters in the range 10.5-12 A. The dynamics at room temperature showed that, as the amphiphile moves to the hollow cage, water molecules are dragged together, thereby promoting the nanotube filling. The resulting densities of filled SWNT are in agreement with measured densities.
Relationship of vocal cord paralysis to the coil diameter of vagus nerve stimulator leads.
Robinson, Leslie C; Winston, Ken R
2015-03-01
This investigation was done to examine, following implantation of vagus nerve stimulators, the relationship of vocal cord paralysis to the inner diameter of the coils used to attach the stimulator lead to the nerve. All data in this investigation were collected, as mandated by the FDA, by the manufacturer of vagus nerve stimulators and were made available without restrictions for analysis by the authors. The data reflect all initial device implantations in the United States for the period from 1997 through 2012. Vocal cord paralysis was reported in 193 of 51,882 implantations. In patients aged 18 years and older, the incidence of paralysis was 0.26% when the stimulator leads had coil diameters of 3 mm and 0.51% when the leads had 2-mm-diameter coils (p < 0.05). Across all age groups, the incidence of vocal cord paralysis increased with age at implantation for leads having 2-mm-diameter coils. In patients aged 18 years and older, vocal cord paralysis occurred at almost twice the rate with the implantation of vagus nerve stimulator leads having 2-mm-diameter coils than with leads having 3-mm-diameter coils. The incidence of vocal cord paralysis increases with patient age at implantation.
Szpinda, Michał; Szpinda, Anna
2012-01-01
Normative data on the diameters of the aorto-iliac segment are extremely useful in the diagnosis and monitoring of prenatal arterial variants and pathologies. The present study describes age-specific reference intervals and normal growth curves for the external diameters of the external and internal iliac arteries. Using anatomical dissection and digital-image analysis, the normal growth of the external diameters of the external and internal iliac arteries was studied in 124 spontaneously aborted human fetuses, aged 15-34 weeks. Neither sex differences nor laterality differences were found. The external diameters of the external iliac arteries increased from 0.31 +/- 0.06 to 1.41 +/- 0.31 mm on the right, and from 0.29 +/- 0.04 to 1.37 +/- 0.24 mm on the left, and generated the following growth curves of best fit: y = 0.665 - 0.056 x Age + 0.002 x Age2 +/- 0.143 (R2 = 0.82) and y = 0.612 - 0.052 x Age + 0.002 x Age2 +/- 0.118 (R2 = 0.86), respectively. The external diameters of the internal iliac arteries were found to be statistically larger than those of the external iliac arteries (p = 0.0000). The external diameters of the internal iliac arteries ranged from 0.44 +/- 0.07 to 2.04 +/- 0.43 mm on the right, and from 0.44 +/- 0.06 to 1.83 +/- 0.43 mm on the left, and modeled the following quadratic functions: y = 1.524 - 0.127 x Age + 0.004 x Age2 +/- 0.242 (R2 = 0.74), and y = 1.391 - 0.117 x Age + 0.004 x Age2 +/- 0.220 (R2 = 0.76), respectively. The right external iliac arteries (in 71% of the cases) and the right internal iliac arteries (in 65.3% of cases) were larger in external diameter. The values of the external diameters of the external and internal iliac arteries are independent of sex. A strong trend towards higher values for the right external and internal iliac arteries is noted. The external diameter of the internal iliac artery is nearly 1.5 times greater than that of the external iliac artery. Surprisingly, normal growth of the external diameters of the external and internal iliac arteries follows quadratic functions.
Grunert, R; Schleifenbaum, S; Möbius, R; Sommer, G; Zajonz, D; Hammer, N; Prietzel, T
2017-02-01
Background: In total hip arthroplasty (THA), femoral head diameter has not been regarded as a key parameter which should be restored when reconstructing joint biomechanics and geometry. Apart from the controversial discussion on the advantages and disadvantages of using larger diameter heads, their higher cost is another important reason that they have only been used to a limited extent. The goal of this study was to analyse the price structure of prosthetic heads in comparison to other components used in THA. A large group of patients with hip endoprostheses were evaluated with respect to the implanted socket diameter and thus the theoretically attainable head diameter. Materials and Methods: The relative prices of various THA components (cups, inserts, stems and ball heads) distributed by two leading German manufacturers were determined and analysed. Special attention was paid to different sizes and varieties in a series of components. A large patient population treated with THA was evaluated with respect to the implanted cup diameter and therefore the theoretically attainable head diameter. Results: The pricing analysis of the THA components of two manufacturers showed identical prices for cups, inserts and stems in a series. In contrast to this, the prices for prosthetic heads with a diameter of 36-44 mm were 11-50 % higher than for 28 mm heads. Identical prices for larger heads were the exception. The distribution of the head diameter in 2719 THA cases showed significant differences between the actually implanted and the theoretically attainable heads. Conclusion: There are proven advantages in using larger diameter ball heads in THA and the remaining problems can be solved. It is therefore desirable to correct the current pricing practice of charging higher prices for larger components. Instead, identical prices should be charged for all head diameters in a series, as is currently established practice for all other THA components. Thus when reconstructing biomechanics and joint geometry in THA, it should be possible to recover not only leg length, femoral offset and antetorsion of the femoral neck, but also to approximately restore the diameter of the femoral head and thereby optimise the functional outcome. Georg Thieme Verlag KG Stuttgart · New York.
Shiqing, Liu; Wenxu, Qi; Jin, Zhang; Youjing, Dong
2018-04-01
The aims of this study were to measure diameters of the cricoid ring and left main bronchus in Asian adult patients and to assess the accuracy of double lumen tube size selected according to cricoid and left main bronchus diameter, respectively. Retrospective observational study. Academic, tertiary care hospital. Preoperative CT scans from 87 men and 94 women who had undergone general anesthesia for lung operations. No intervention. The diameters of the cricoid ring and left main bronchus were measured from thoracic computed tomography images after correction of slant. The "best-fit" size of double lumen tube was determined by comparing diameter of the left main bronchus and cricoid ring with the diameter of the double lumen tube. Diameters of the cricoid ring and left main bronchus were both significantly greater in men compared with women (p < 0.0001). Shapes of cricoid rings were different between genders (p < 0.0001), while shapes of the left main bronchus were not significant different (p = 0.343). With reference to the "best fit" size, the rate of agreement of cricoid ring size, left main bronchus size, and height size for men were 100%, 100%, and 94.3%. For women, the rate of agreement of cricoid ring size, left main bronchus size, and height size were 94.7%, 63.8%, and 51.1%. The "best fit" size of a double lumen tube should be decided by a combination of diameters of the cricoid ring and the left main bronchus. Copyright © 2017 Elsevier Inc. All rights reserved.
Growth of ponderosa pine seedlings as affected by air pollution
NASA Astrophysics Data System (ADS)
Momen, B.; Anderson, P. D.; Houpis, J. L. J.; Helms, J. A.
The effect of air pollution on seedling survival and competitive ability is important to natural and artificial regeneration of forest trees. Although biochemical and physiological processes are sensitive indicators of pollution stress, the cumulative effects of air pollutants on seedling vigor and competitive ability may be assessed directly from whole-plant growth characteristics such as diameter, height, and photosynthetic area. A few studies that have examined intraspecific variation in seedling response to air pollution indicate that genotypic differences are important in assessing potential effects of air pollution on forest regeneration. Here, we studied the effects of acid rain (no-rain, pH 5.1 rain, pH 3.0 rain) and ozone (filtered, ambient, twice-ambient) in the field on height, diameter, volume, the height:diameter ratio, maximum needle length, and time to reach maximum needle length in seedlings of three families of ponderosa pine ( Pinus ponderosa Dougl. ex Laws). Seedling diameter, height, volume, and height:diameter ratio related significantly to their pre-treatment values. Twice-ambient ozone decreased seedling diameter compared with ozone-filtered air. A significant family-by-ozone interaction was detected for seedling height, as the height of only one of the three families was decreased by twice-ambient ozone compared with the ambient level. Seedling diameter was larger and the height:diameter ratio was smaller under pH 3.0 rain compared to either the no-rain or the pH 5.1-rain treatment. This suggests greater seedling vigor, perhaps due to a foliar fertilization effect of the pH 3.0 rain.
Ferris, Lara; Schar, Mistyka; McCall, Lisa; Doeltgen, Sebastian; Scholten, Ingrid; Rommel, Nathalie; Cock, Charles; Omari, Taher
2018-06-01
Characterization of the pharyngeal swallow response to volume challenges is important for swallowing function assessment. The diameter of the pressure-impedance recording catheter may influence these results. In this study, we captured key physiological swallow measures in response to bolus volume utilizing recordings acquired by two catheters of different diameter. Ten healthy adults underwent repeat investigations with 8- and 10-Fr catheters. Liquid bolus swallows of volumes 2.5, 5, 10, 20, and 30 mL were recorded. Measures indicative of distension, contractility, and flow timing were assessed. Pressure-impedance recordings with pressure-flow analysis were used to capture key distension, contractility, and pressure-flow timing parameters. Larger bolus volumes increased upper esophageal sphincter distension diameter (P < .001) and distension pressures within the hypopharynx and upper esophageal sphincter (P < .05). Bolus flow timing measures were longer, particularly latency of bolus propulsion ahead of the pharyngeal stripping wave (P < .001). Use of a larger-diameter catheter produced higher occlusive pressures, namely upper esophageal sphincter basal pressure (P < .005) and upper esophageal sphincter postdeglutitive pressure peak (P < .001). The bolus volume swallowed changed measurements indicative of distension pressure, luminal diameter, and pressure-flow timing; this is physiologically consistent with swallow modulation to accommodate larger, faster-flowing boluses. Additionally, catheter diameter predominantly affects lumen occlusive pressures. Appropriate physiological interpretation of the pressure-impedance recordings of pharyngeal swallowing requires consideration of the effects of volume and catheter diameter. NA. Laryngoscope, 128:1328-1334, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.
Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron
2017-10-01
Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.
Shabanpour, Reza; Mousavi, Niloufar; Ghodsi, Safoura; Alikhasi, Marzieh
2015-08-01
The purpose of the current study was to compare the fracture resistance and mode of failure of zirconia and titanium abutments with different diameters. Fourteen groups of abutments including prefabricated zirconia, copy-milled zirconia and titanium abutments of an implant system (XiVE, Dentsply) were prepared in different diameters. An increasing vertical load was applied to each specimen until failure occurred. Fracture resistance was measured in each group using the universal testing machine. Moreover, the failure modes were studied and categorized as abutment screw fracture, connection area fracture, abutment body fracture, abutment body distortion, screw distortion and connection area distortion. Groups were statistically compared using univariate and post-hoc tests. The level of statistical significance was set at 5%. Fabrication method (p = 0.03) and diameter (p < 0.001) had significant effect on the fracture resistance of abutments. Fracture resistance of abutments with 5.5 mm diameter was higher than other diameters (p < 0.001). The observed modes of failure were dependent on the abutment material as well. All of the prefabricated titanium abutments fractured within the abutment screw. Abutment screw distortion, connection area fracture, and abutment body fracture were the common failure type in other groups. Diameter had a significant effect on fracture resistance of implant abutments, as abutments with greater diameters were more resistant to static loads. Copy-milled abutments showed lower fracture resistance as compared to other experimental groups. Although zirconia abutments have received great popularity among clinicians and even patients selecting them for narrow implants should be with caution.
Correlation between extraocular muscle size and motility restriction in thyroid eye disease.
Dagi, Lora R; Zoumalan, Christopher I; Konrad, Hindola; Trokel, Stephen L; Kazim, Michael
2011-01-01
Evaluate the relationship between extraocular muscle (EOM) size, measured by computed tomography, and ocular motility in thyroid eye disease (TED). This case series is based on a retrospective review of the records of 54 patients (108 orbits) with TED. Main outcome measures included EOM size and degree of motility restriction. The average diameter of each rectus muscle was compared with published norms. Four subpopulations based on Age (< 40 or ≥ 40 years) and State of thyroid eye disease (active or stable) were studied. Versions were measured by the corneal light reflex method. The trend of muscle diameter versus motility restriction was evaluated. The average EOM diameter was greater than the norm in the study cohort and 4 subpopulations. The average diameter was largest in the Older and Active TED subpopulations. The inferior rectus and medial rectus were most frequently restricted in the study cohort and 4 subpopulations. The medial rectus had the strongest trend between increasing diameter and motility restriction, followed by the inferior rectus and the superior muscle group (comprised of the superior rectus and levator palpebrae superioris). However, there was a general lack of strong correlation between the diameter of the rectus muscles and their respective motility, especially in the Younger subpopulation. EOM diameters are larger and have more restricted motility in the Older and Active TED subpopulations. Contrary to prior publications, the correlation between EOM diameters and motility was weak, especially in the Younger subpopulation. These findings suggest that the pathophysiology of EOM enlargement is different based upon the age of the patient and the activity of the orbitopathy.
Tree-stem diameter fluctuates with the lunar tides and perhaps with geomagnetic activity.
Barlow, Peter W; Mikulecký, Miroslav; Střeštík, Jaroslav
2010-11-01
Our initial objective has been to examine the suggestion of Zürcher et al. (Nature 392:665–666, 1998) that the naturally occurring variations in stem diameter of two experimental trees of Picea alba were related to near simultaneous variations in the lunisolar tidal acceleration. The relationship was positive: Lunar peaks were roughly synchronous with stem diameter peaks. To extend the investigation of this putative relationship, additional data on stem diameter variations from six other tree species were gathered from published literature. Sixteen sets of data were analysed retrospectively using graphical representations as well as cosinor analysis, statistical cross-correlation and cross-spectral analysis, together with estimated values of the lunisolar tidal acceleration corresponding to the sites, dates and times of collection of the biological data. Positive relationships were revealed between the daily variations of stem diameter and the variations of the lunisolar tidal acceleration. Although this relationship could be mediated by a 24.8-h lunar rhythm, the presence of a solar rhythm of 24.0 h could not be ruled out. Studies of transpiration in two of the observed trees indicated that although this variable was not linked to stem diameter variation, it might also be subject to lunisolar gravitational regulation. In three cases, the geomagnetic Thule index showed a weak but reciprocal relationship with stem diameter variation, as well as a positive relationship with the lunisolar tidal force. In conclusion, it seems that lunar gravity alone could influence stem diameter variation and that, under certain circumstances, additional regulation may come from the geomagnetic flux.
Supercritical multicomponent solvent coal extraction
NASA Technical Reports Server (NTRS)
Corcoran, W. H.; Fong, W. S.; Pichaichanarong, P.; Chan, P. C. F.; Lawson, D. D. (Inventor)
1983-01-01
The yield of organic extract from the supercritical extraction of coal with larger diameter organic solvents such as toluene is increased by use of a minor amount of from 0.1 to 10% by weight of a second solvent such as methanol having a molecular diameter significantly smaller than the average pore diameter of the coal.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-27
... DEPARTMENT OF COMMERCE International Trade Administration [A-588-851] Certain Small Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe (Under 4\\1/2\\ Inches) From Japan: Rescission... antidumping order on certain small diameter carbon and alloy seamless standard, line and pressure pipe (under...
Method for applying pyrolytic carbon coatings to small particles
Beatty, Ronald L.; Kiplinger, Dale V.; Chilcoat, Bill R.
1977-01-01
A method for coating small diameter, low density particles with pyrolytic carbon is provided by fluidizing a bed of particles wherein at least 50 per cent of the particles have a density and diameter of at least two times the remainder of the particles and thereafter recovering the small diameter and coated particles.
Individual tree-diameter growth model for the Northeastern United States
Richard M. Teck; Donald E. Hilt
1991-01-01
Describes a distance-independent individual-tree diameter growth model for the Northeastern United States. Diameter growth is predicted in two steps using a two parameter, sigmoidal growth function modified by a one parameter exponential decay function with species-specific coefficients. Coefficients are presented for 28 species groups. The model accounts for...
A mixed-effects height-diameter model for cottonwood in the Mississippi Delta
Curtis L. VanderSchaaf; H. Christoph Stuhlinger
2012-01-01
Eastern cottonwood (Populus deltoides Bartr. ex Marsh.) has been artificially regenerated throughout the Mississippi Delta region because of its fast growth and is being considered for biofuel production.This paper presents a mixed-effects height-diameter model for cottonwood in the Mississippi Delta region. After obtaining height-diameter...
Diameter Distributions of Longleaf Pine Plantations-A Neural Network Approach
Daniel J. Leduc; Thomas G. Matney; V. Clark Baldwin
1999-01-01
The distribution of trees into diameter classes in longleaf pine (Pinus palustris Mill.) plantations does not tend to produce the smooth distributions common to other southern pines. While these distributions are sometimes unimodal, they are frequently bi- or even tri-modal and for this reason may not be easily modeled with traditional diameter...
Growth and Branching of Young Cottonwoods After Pruning
Roger M. Krinard
1976-01-01
Although spring and summer pruning to various heights reduced diameter growth for the treatment year, diameter increment of most pruned trees did not differ significantly from that of controls 2 years after treatment. Total diameter growth during the test period was significantly less for pruned trees than for controls. Epicormic branching increased with spring...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-07
... Pipe From Japan: Notice of Rescission of Antidumping Duty Administrative Review AGENCY: Import... antidumping duty order on welded large diameter line pipe from Japan. The review covers 4 producers/exporters of welded large diameter line pipe from Japan, which are, JFE Steel Corporation, Nippon Steel...
78 FR 60897 - Certain Welded Large Diameter Line Pipe From Japan
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
... Diameter Line Pipe From Japan Determination On the basis of the record \\1\\ developed in the subject five... order on certain welded large diameter line pipe from Japan would likely to lead to continuation or... Line Pipe from Japan: Investigation No. 731-TA-919 (Second Review). By order of the Commission. Issued...
Forest Products Laboratory research program on small-diameter material.
2000-01-01
Forests in the United States contain a significant amount of small-diameter and underutilized material. These overstocked stands not only increase the risk of insect, disease, fire, and drought damage, but also are costly to remove. Finding economical and marketable uses for small-diameter and underutilized material would alleviate these problems while improving...
Code of Federal Regulations, 2011 CFR
2011-07-01
... shot or similar abrasive which may create a slipping hazard. (8) Scope. This paragraph (a) applies to... wheels, the thickness of which is not more than one forty-eighth of their diameter for those up to, and including, 20 inches in diameter, and not more than one-sixtieth of their diameter for those larger than 20...
Code of Federal Regulations, 2013 CFR
2013-07-01
... shall be cleaned up promptly. Aisles and walkways shall be kept clear of steel shot or similar abrasive... not more than one forty-eighth of their diameter for those up to, and including, 20 inches (50.8 cm) in diameter, and not more than one-sixtieth of their diameter for those larger than 20 inches (50.8...
49 CFR 179.300-6 - Thickness of plates.
Code of Federal Regulations, 2010 CFR
2010-10-01
....037 Where: d = inside diameter in inches; E = 1.0 welded joint efficiency; P = minimum required bursting pressure in psig; S = minimum tensile strength of plate material in p.s.i. as prescribed in § 179... −d 2) where: d = inside diameter in inches; D = outside diameter in inches; p = tank test pressure in...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-19
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-929] Small Diameter Graphite Electrodes From the People's Republic of China: Extension of Time Limit for the Preliminary Results of the... review of the antidumping duty order on small diameter graphite electrodes from the People's Republic of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-01
... DEPARTMENT OF COMMERCE International Trade Administration [A-570-929] Small Diameter Graphite... diameter graphite electrodes from the People's Republic of China (PRC) for the period February 1, 2010... Graphite, Co. The preliminary results of the review are currently due no later than October 31, 2011...
Short pulse duration shock initiation experiments plus ignition and growth modeling on Composition B
NASA Astrophysics Data System (ADS)
May, Chadd M.; Tarver, Craig M.
2014-05-01
Composition B (63% RDX, 36% TNT, 1% wax) is still a widely used energetic material whose shock initiation characteristics are necessary to understand. It is now possible to shock initiate Composition B and other secondary explosives at diameters well below their characteristic failure diameters for unconfined self-sustaining detonation. This is done using very high velocity, very thin, small diameter flyer plates accelerated by electric or laser power sources. Recently experimental detonation versus failure to detonate threshold flyer velocity curves for Composition B using several KaptonTM flyer thicknesses and diameters were measured. Flyer plates with diameters of 2 mm successfully detonated Composition B, which has a nominal failure diameter of 4.3 mm. The shock pressures required for these initiations are greater than the Chapman-Jouguet (C-J) pressure in self-sustaining Composition B detonation waves. The initiation process is two-dimensional, because both rear and side rarefactions can affect the shocked Composition B reaction rates. The Ignition and Growth reactive flow model for Composition B is extended to yield accurate simulations of this new threshold velocity data for various flyer thicknesses.
Diameter Effect Curve and Detonation Front Curvature Measurements for ANFO
NASA Astrophysics Data System (ADS)
Catanach, R. A.; Hill, L. G.
2002-07-01
Diameter effect and front curvature measurements are reported for rate stick experiments on commercially available prilled ANFO (ammonium-nitrate/fuel-oil) at ambient temperature. The shots were fired in paper tubes so as to provide minimal confinement. Diameters ranged from 77 mm (approximately failure diameter) to 205 mm, with the tube length being ten diameters in all cases. Each detonation wave shape was fit with an analytic form, from which the local normal velocity Dn, and local total curvature kappa, were generated as a function of radius R, then plotted parametrically to generate a Dn(kappa) function. The observed behavior deviates substantially from that of previous explosives, for which curves for different diameters overlay well for small kappa but diverge for large kappa, and for which kappa increases monotonically with R. For ANFO, we find that Dn(kappa) curves for individual sticks 1) show little or no overlap--with smaller sticks lying to the right of larger ones, 2) exhibit a large velocity deficit with little kappa variation, and 3) reach a peak kappa at an intermediate R.
Size effects on miniature Stirling cycle cryocoolers
NASA Astrophysics Data System (ADS)
Yang, Xiaoqin; Chung, J. N.
2005-08-01
Size effects on the performance of Stirling cycle cryocoolers were investigated by examining each individual loss associated with the regenerator and combining these effects. For the fixed cycle parameters and given regenerator length scale, it was found that only for a specific range of the hydrodynamic diameter the system can produce net refrigeration and there is an optimum hydraulic diameter at which the maximum net refrigeration is achieved. When the hydraulic diameter is less than the optimum value, the regenerator performance is controlled by the pressure drop loss; when the hydraulic diameter is greater than the optimum value, the system performance is controlled by the thermal losses. It was also found that there exists an optimum ratio between the hydraulic diameter and the length of the regenerator that offers the maximum net refrigeration. As the regenerator length is decreased, the optimum hydraulic diameter-to-length ratio increases; and the system performance is increased that is controlled by the pressure drop loss and heat conduction loss. Choosing appropriate regenerator characteristic sizes in small-scale systems are more critical than in large-scale ones.
Panda, Shasanka Shekhar; Bajpai, Minu; Mallick, Saumyaranjan; Sharma, Mehar C
2014-01-01
The objective of the following study is to determine and to compare the different morphological parameters with duration of obstruction created experimentally in unilateral upper ureters of rats. Unilateral upper ureteric obstruction was created in 60 adult Wistar rats that were reversed after predetermined intervals. Rats were sacrificed and ipsilateral kidneys were subjected for analysis of morphological parameters such as renal height, cranio-caudal diameter, antero-posterior diameter, lateral diameter, volume of the pelvis and average cortical thickness: Renal height. Renal height and cranio-caudal diameter of renal pelvis after ipsilateral upper ureteric obstruction started rising as early as 7 days of creating obstruction and were affected earlier than antero-posterior and lateral diameter and also were reversed earlier than other parameters after reversal of obstruction. Renal cortical thickness and volume of the pelvis were affected after prolonged obstruction (> 3 weeks) and were the late parameters to be reversed after reversal of obstruction. Cranio-caudal diameter and renal height were the early morphological parameters to be affected and reversed after reversal of obstruction in experimentally created ipsilateral upper ureteric obstruction.
Irazuzta, Jose E; Brown, Martha E; Akhtar, Javed
2016-01-01
We determined whether the bedside assessment of the optic nerve sheath diameter could identify elevated intracranial pressure in individuals with suspected idiopathic intracranial hypertension. This was a single-center, prospective, rater-blinded study performed in a freestanding pediatric teaching hospital. Patients aged 12 to 18 years scheduled for an elective lumbar puncture with the suspicion of idiopathic intracranial hypertension were eligible to participate. Optic nerve sheath diameter was measured via ultrasonography before performing a sedated lumbar puncture for measuring cerebrospinal fluid opening pressure. Abnormal measurements were predefined as optic nerve sheath diameter ≥4.5 mm and a cerebrospinal fluid opening pressure greater than 20 cmH2O. Thirteen patients participated in the study, 10 of whom had elevated intracranial pressure. Optic nerve sheath diameter was able to predict or rule out elevated intracranial pressure in all patients. Noninvasive assessment of the optic nerve sheath diameter could help to identify patients with elevated intracranial pressure when idiopathic intracranial hypertension is suspected. Copyright © 2016 Elsevier Inc. All rights reserved.
Compositional Variation in Large-Diameter Low-Albedo asteroids
NASA Astrophysics Data System (ADS)
Vilas, F.; Jarvis, K. S.; Thibault, C. A.; Sawyer, S. R.
2000-12-01
Age dating of meteorites indicates that the Solar System was subjected to a major heating event 4.5 Gyr ago. Models of the effects of heating by electromagnetic induction or decay of short-lived radionuclides combined with models of the early collisional history of the Solar System after Jupiter's formation indicate that asteroids observed today can be divided into two groups by diameter. Those asteroids having diameters greater than 100 km were mixed by multiple collisions but remain as gravitationally bound rubble piles. Asteroids with diameters less than 100 km should show more compositional diversity. Vilas and Sykes (1996, Icarus, 124) have shown using ECAS photometry that this compositional difference exists. The larger diameter group should be individually homogenous, with spectral differences showing the combined effects of a primordial compositional gradient in the asteroid belt with thermal metamorphism. We address the significance of 36 rotationally-resolved spectra of larger-diameter low-albedo asteroids of the C class (and subclasses B, F, G) and P class in the visible and Near-IR spectral regions. This work was supported by the NASA Planetary Astronomy program.
Modeling light scattering in the shadow region behind thin cylinders for diameter analysis
NASA Astrophysics Data System (ADS)
Blohm, Werner
2018-03-01
In this paper, the scattered light intensities resulting in the shadow region at an observation plane behind monochromatically illuminated circular cylinders are modeled by sinusoidal sequences having a squared dependence on spatial position in the observation plane. Whereas two sinusoidal components appear to be sufficient for modeling the light distribution behind intransparent cylinders, at least three sinusoidal components are necessary for transparent cylinders. Based on this model, a novel evaluation algorithm for a very fast retrieval of the diameter of thin cylindrical products like metallic wires and transparent fibers is presented. This algorithm was tested in a cylinder diameter range typical for these products (d ≈ 70 … 150 μm; n ≈ 1.5). Numerical examples are given to illustrate its application by using both synthetic and experimental scattering data. Diameter accuracies below 0.05 μm could be achieved for intransparent cylinders in the tested diameter range. However, scattering effects due to morphological-dependent resonances (MDRs) are problematical in the diameter analysis of transparent products. In order to incorporate these effects into the model, further investigations are needed.
Ahadi, Zohreh; Shadman, Muhammad; Yeganegi, Saeed; Asgari, Farid
2012-07-01
Hydrogen adsorption in multi-walled boron nitride nanotubes and their arrays was studied using grand canonical Monte Carlo simulation. The results show that hydrogen storage increases with tube diameter and the distance between the tubes in multi-walled boron nitride nanotube arrays. Also, triple-walled boron nitride nanotubes present the lowest level of hydrogen physisorption, double-walled boron nitride nanotubes adsorb hydrogen better when the diameter of the inner tube diameter is sufficiently large, and single-walled boron nitride nanotubes adsorb hydrogen well when the tube diameter is small enough. Boron nitride nanotube arrays adsorb hydrogen, but the percentage of adsorbed hydrogen (by weight) in boron nitride nanotube arrays is rather similar to that found in multi-walled boron nitride nanotubes. Also, when the Langmuir and Langmuir-Freundlich equations were fitted to the simulated data, it was found that multi-layer adsorptivity occurs more prominently as the number of walls and the tube diameter increase. However, in single-walled boron nitride nanotubes with a small diameter, the dominant mechanism is monolayer adsorptivity.
Pipe support for use in a nuclear system
Pollono, Louis P.; Mello, Raymond M.
1977-01-01
A pipe support for high temperature, thin-walled vertical piping runs used in a nuclear system. A cylindrical pipe transition member, having the same inside diameter as the thin-walled piping, replaces a portion of the piping where support is desired. The outside diameter of the pipe transition member varies axially along its vertical dimension. For a section of the axial length adjacent the upper and lower terminations of the pipe transition member, the outside diameter is the same as the outside diameter of the thin-walled piping to which it is affixed. Intermediate of the termination sections, the outside diameter increases from the top of the member to the bottom. Adjacent the lower termination section, the diameter abruptly becomes the same as the piping. Thus, the cylindrical transition member is formed to have a generally triangular shaped cross-section along the axial dimension. Load-bearing insulation is installed next to the periphery of the member and is kept in place by an outer ring clamp. The outer ring clamp is connected to pipe hangers, which provide the desired support for the vertical thin-walled piping runs.
Numerical Investigation of Liquid Carryover in T-Junction with Different Diameter Ratios
NASA Astrophysics Data System (ADS)
Pao, William; Sam, Ban; Saieed, Ahmed; Tran, Cong Minh
2018-03-01
In offshore Malaysia, T-junction is installed at the production header as a compact separator to tap produced gas from reservoir as fuel gas for power generation. However, excessive liquid carryover in T-junction presents a serious operational issue because it trips the whole production platform. The primary objective of present study is to numerically investigate the liquid carryover due to formation of slug, subsequently its liquid carryover at different diameter ratio. The analyses were carried out on a model with 0.0254 m (1 inch) diameter horizontal main arm and a vertically upward side arm using Volume of Fluid Method. Three different sides to main arm diameter ratio of 1.0, 0.5 and 0.3 were investigated with different gas and liquid superficial velocities. The results showed that, while the general trend is true that smaller diameter ratio T-junction has lesser liquid take off capacity, it has a very high frequency of low liquid carryover threshold. In other words, under slug flow, smaller diameter ratio T-junction is constantly transporting liquid even though at a lesser volume in comparison to regular T-junction.
Fukunaga, Masaaki; Onishi, Hideo; Matsutomo, Norikazu; Yamamoto, Hiroyuki
2016-06-01
The purpose of this study was to evaluate the effects of target diameter and display-field of view (D-FOV) in modulation transfer function (MTF) by circular edge strategy using the computed tomography (CT) image measurement program "CTmeasure". We calculated the MTF (MTF(edge)) using the circular edge strategy applied to cylindrical phantom (200 mmφ) that inserted with cylinders have 10, 20, 30, and 40 mm diameters. The phantom images were reconstructed using filtered back projection method varied with D-FOV (240, 320, 400, and 500 mm). The study compared both MTF(edge) and MTF(wire) at MTF50% and MTF(10%) for target diameter and D-FOV, respectively. The MTF(edge) by the different of target diameter indicated in rough compatibility. However, MTF(edge) of D-FOV diameters (320, 400, and 500 mm) decreased in the high frequency range. The circular edge strategy for MTF depended on the D-FOV, however, it was little dependent on target diameter using the CT image measurement program "CTmeasure".
Simulation on Effect of Preform Diameter in Injection Stretch Blow Molding
NASA Astrophysics Data System (ADS)
Tan, Z. Q.; Rosli, Nurrina; Oktaviandri, Muchamad
2018-03-01
Polyethylene terephthalate (PET) is the most common material of resin for manufacturing plastic bottle by injection stretch blow molding due to its excellent properties. As various issues of health and environmental hazards due to the PET use have risen, PET bottle manufacture may be improved by minimizing the wall thickness to reduce the PET use. One of the critical qualifications of the manufacturing process which lead to the wall thickness distribution is the initial preform diameter. In this project, we used the ANSYS Polyflow with aim to evaluate the wall thickness distribution of PET bottle for different diameter of initial preform. As a result, only 4 mm preform diameter presented wall thickness below than 1 mm. On the other hand, at least 6 mm preform diameter can permit the wall thickness 1.3 mm i.e. at the shoulder area.
NASA Astrophysics Data System (ADS)
Forsman, Mona; Börlin, Niclas; Olofsson, Kenneth; Reese, Heather; Holmgren, Johan
2018-01-01
In this study we have investigated why diameters of tree stems, which are approximately cylindrical, are often overestimated by mobile laser scanning. This paper analyzes the physical processes when using ground-based laser scanning that may contribute to a bias when estimating cylinder diameters using circle-fit methods. A laser scanner simulator was implemented and used to evaluate various properties, such as distance, cylinder diameter, and beam width of a laser scanner-cylinder system to find critical conditions. The simulation results suggest that a positive bias of the diameter estimation is expected. Furthermore, the bias follows a quadratic function of one parameter - the relative footprint, i.e., the fraction of the cylinder width illuminated by the laser beam. The quadratic signature opens up a possibility to construct a compensation model for the bias.
Diameter modulation of vertically aligned single-walled carbon nanotubes.
Xiang, Rong; Einarsson, Erik; Murakami, Yoichi; Shiomi, Junichiro; Chiashi, Shohei; Tang, Zikang; Maruyama, Shigeo
2012-08-28
We demonstrate wide-range diameter modulation of vertically aligned single-walled carbon nanotubes (SWNTs) using a wet chemistry prepared catalyst. In order to ensure compatibility to electronic applications, the current minimum mean diameter of 2 nm for vertically aligned SWNTs is challenged. The mean diameter is decreased to about 1.4 nm by reducing Co catalyst concentrations to 1/100 or by increasing Mo catalyst concentrations by five times. We also propose a novel spectral analysis method that allows one to distinguish absorbance contributions from the upper, middle, and lower parts of a nanotube array. We use this method to quantitatively characterize the slight diameter change observed along the array height. On the basis of further investigation of the array and catalyst particles, we conclude that catalyst aggregation-rather than Ostwald ripening-dominates the growth of metal particles.
Wavelength dependence of the apparent diameter of retinal blood vessels
NASA Astrophysics Data System (ADS)
Park, Robert; Twietmeyer, Karen; Chipman, Russell; Beaudry, Neil; Salyer, David
2005-04-01
Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column.
NASA Astrophysics Data System (ADS)
Sun, Xu; Gu, Yousong; Wang, Xueqiang
2012-08-01
One dimensional ZnO NWs with different diameters and lengths have been investigated using density functional theory (DFT) and Maximally Localized Wannier Functions (MLWFs). It is found that ZnO NWs are direct band gap semiconductors and there exist a turn on voltage for observable current. ZnO nanowires with different diameters and lengths show distinctive turn-on voltage thresholds in I-V characteristics curves. The diameters of ZnO NWs are greatly influent the transport properties of ZnO NWs. For the ZnO NW with large diameter that has more states and higher transmission coefficients leads to narrow band gap and low turn on voltage. In the case of thinner diameters, the length of ZnO NW can effects the electron tunneling and longer supercell lead to higher turn on voltage.
Crystallisation via novel 3D nanotemplates as a tool for protein purification and bio-separation
NASA Astrophysics Data System (ADS)
Shah, Umang V.; Jahn, Niklas H.; Huang, Shanshan; Yang, Zhongqiang; Williams, Daryl R.; Heng, Jerry Y. Y.
2017-07-01
This study reports an experimental validation of the surface preferential nucleation of proteins on the basis of a relationship between nucleant pore diameter and protein hydrodynamic diameter. The validated correlation was employed for the selection of nucleant pore diameter to crystallise a target protein from binary, equivolume protein mixture. We report proof-of-concept preliminary experimental evidence for the rational approach for crystallisation of a target protein from a binary protein mixture on the surface of 3D nanotemplates with controlled surface porosity and narrow pore-size distribution selected on the basis of a relationship between the nucleant pore diameter and protein hydrodynamic diameter. The outcome of this study opens up an exciting opportunity for exploring protein crystallisation as a potential route for protein purification and bio-separation in both technical and pharmaceutical applications.
Porosity Assessment for Different Diameters of Coir Lignocellulosic Fibers
NASA Astrophysics Data System (ADS)
da Luz, Fernanda Santos; Paciornik, Sidnei; Monteiro, Sergio Neves; da Silva, Luiz Carlos; Tommasini, Flávio James; Candido, Verônica Scarpini
2017-10-01
The application of natural lignocellulosic fibers (LCFs) in engineering composites has increased interest in their properties and structural characteristics. In particular, the inherent porosity of an LCF markedly affects its density and the adhesion to polymer matrices. For the first time, both open and closed porosities of a natural LCF, for different diameter ranges, were assessed. Fibers extracted from the mesocarp of the coconut fruit were investigated by nondestructive methods of density measurements and x-ray microtomography (microCT). It was found that, for all diameter ranges, the closed porosity is significantly higher than the open porosity. The total porosity increases with diameter to around 60% for coir fibers with more than 503 μm in diameter. The amount and characteristics of these open and closed porosities were revealed by t test and Weibull statistics as well as by microCT.
Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.
Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm
2014-02-01
In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%.
Fischer, Andreas; Bausch, Dirk; Richter-Schrag, Hans-Juergen
2013-02-01
The use of self-expandable stents to treat postoperative leaks and fistula in the upper gastrointestinal (GI) tract is an established treatment for leaks of the upper GI tract. However, lumen-to-stent size discrepancies (i.e., after sleeve gastrectomy or esophageal resection) may lead to insufficient sealing of the leaks requiring further surgical intervention. This is mainly due to the relatively small diameter (≤30 mm) of commonly used commercial stents. To overcome this problem, we developed a novel partially covered stent with a shaft diameter of 36 mm and a flare diameter of 40 mm. From September 2008 to September 2010, 11 consecutive patients with postoperative leaks were treated with the novel large diameter stent (gastrectomy, n = 5; sleeve gastrectomy, n = 2; fundoplication after esophageal perforation, n = 2; Roux-en-Y gastric bypass, n = 1; esophageal resection, n = 1). Treatment with commercially available stents (shaft/flare: 23/28 mm and 24/30 mm) had been unsuccessful in three patients before treatment with the large diameter stent. Due to dislocation, the large diameter stent was anchored in four patients (2× intraoperatively with transmural sutures, 2× endoscopically with transnasally externalized threads). Treatment was successful in 11 of 11 patients. Stent placement and removal was easy and safe. The median residence time of the stent was 24 (range, 18-41) days. Stent dislocation occurred in four cases (36 %). It was treated by anchoring the stent. Mean follow-up was 25 (range, 14-40) months. No severe complication occurred during or after intervention and no patient was dysphagic. Using the novel large diameter, partially covered stent to seal leaks in the upper GI tract is safe and effective. The large diameter of the stent does not seem to injure the wall of the upper GI tract. However, stent dislocation sometimes requires anchoring of the stent with sutures or transnasally externalized threads.
Central obesity is an independent predictor of erectile dysfunction in older men.
Riedner, Charles Edison; Rhoden, Ernani Luis; Ribeiro, Eduardo Porto; Fuchs, Sandra Costa
2006-10-01
There is a growing body of evidence in the literature correlating erectile dysfunction to obesity. We investigated the correlation of different anthropometric indexes of central obesity to erectile dysfunction. A cross-sectional study was performed including 256 consecutive men 40 years old or older. All men completed the International Index of Erectile Function, and were evaluated routinely with a clinical history, physical examination and blood analysis for fasting serum glucose, lipid profile and serum testosterone. Anthropometric measures included body mass index, waist circumference, sagittal abdominal diameter, maximal abdominal circumference, and waist-hip, waist-thigh, waist-height, sagittal abdominal diameter-thigh and sagittal abdominal diameter-height indexes. In men 40 to 60 years old the different anthropometric indexes of central obesity were not correlated with the presence of erectile dysfunction (p > 0.05). Men older than 60 years (41%, range 61 to 81) demonstrated an association among erectile dysfunction and waist-hip index (p = 0.04), waist-thigh index (p = 0.02), sagittal abdominal diameter (p = 0.03), sagittal abdominal diameter-height index (p = 0.02) and maximal abdominal circumference (p = 0.04). After logistic regression analysis an independent effect on the presence of erectile dysfunction was observed for waist-hip index (OR 8.56, 95% CI 1.44-50.73), sagittal abdominal diameter (OR 7.87, 95% CI 1.24-49.75), sagittal abdominal diameter-height index (OR 14.21, 95% CI 1.11-182.32), maximum abdominal circumference (OR 11.72, 95% CI 1.73-79.18) and waist circumference (OR 19.37, 95% CI 1.15-326.55). This study suggests that central obesity, assessed by several anthropometric indicators, is associated to the presence of erectile dysfunction in men older than 60 years. Sagittal abdominal diameter, sagittal abdominal diameter-height index, maximum abdominal circumference, waist circumference and waist-hip index were useful indicators to predict the presence of erectile dysfunction.
[Predictability of the corneal flap creation with the femtosecond laser in LASIK].
Mai, Zhi-bin; Liu, Su-bing; Nie, Xiao-li; Sun, Hong-xia; Xin, Bao-li; Tang, Xiu-xia
2012-05-01
To observe the predictability of corneal flap creation with the FEMTO LDV femtosecond laser and analyze preliminarily the factors correlating to the thickness and diameter of the flap . It was a study of serial cases. 260 eyes of 130 consecutive patients were treated with the FEMTO LDV. The eyes were assigned to two groups according to intended flap thickness, 110 µm (208 eyes) and 90 µm (52 eyes). Intended flap diameter varied from 8.5 to 9.5 mm. Difference analysis of flap diameter and intended diameter as well as flap thickness and intended thickness were made. The data was analyzed with SPSS to sum up a multiple stepwise regression formula that could express their quantitative relationship. The 90 µm flap group had a average flap thickness of (95.12 ± 7.65) µm, while for the 110 µm group the average flap thickness was (104.81 ± 3.09) µm. The difference between right and left eyes was not statistically significant (t(110 µm) = -1.223, t(90 µm) = -1.343, P > 0.05). Corneal flap thickness was inversely correlated with flap diameter (r(110 µm) = -0.143, r(90 µm) = -0.315, P < 0.05), but was not related to preoperative patient age, corneal thickness, keratometric value K or intraocular pressure (r(110 µm) = -0.160, 0.054, -0.011, -0.363; r(90 µm) = 0.024, 0.074, -0.212, -0.434, all P > 0.05). Corneal flap diameter was positively correlated with preoperative corneal keratometric value K and thickness (P < 0.001, P < 0.05). Multiple stepwise regression analysis showed flap diameter was an influencing factor for flap thickness. Preoperative corneal keratometric value K and thickness were influencing factors for flap diameter. The LASIK flap creation with the FEMTO LDV laser has relatively good predictability. Flap diameter is an influencing factor for flap thickness.
Mbah, Nsehniitooh; Philips, Prejesh; Voor, Michael J; Martin, Robert C G
2017-12-01
The optimal use of esophageal stents for malignant and benign esophageal strictures continues to be plagued with variability in pain tolerance, migration rates, and reflux-related symptoms. The aim of this study was to evaluate the differences in radial force exhibited by a variety of esophageal stents with respect to the patient's esophageal stricture. Radial force testing was performed on eight stents manufactured by four different companies using a hydraulic press and a 5000 N force gage. Radial force was measured using three different tests: transverse compression, circumferential compression, and a three-point bending test. Esophageal stricture composition and diameters were measured to assess maximum diameter, length, and proximal esophageal diameter among 15 patients prior to stenting. There was a statistically significant difference in mean radial force for transverse compression tests at the middle (range 4.25-0.66 newtons/millimeter N/mm) and at the flange (range 3.32-0.48 N/mm). There were also statistical differences in mean radial force for circumferential test (ranged from 1.19 to 10.50 N/mm, p < 0.001) and the three-point bending test (range 0.08-0.28 N/mm, p < 0.001). In an evaluation of esophageal stricture diameters and lengths, the smallest median diameter of the stricture was 10 mm (range 5-16 mm) and the median proximal diameter normal esophagus was 25 mm (range 22-33 mm), which is currently outside of the range of stent diameters. Tested stents demonstrated significant differences in radial force, which provides further clarification of stent pain and intolerance in certain patients, with either benign or malignant disease. Similarly, current stent diameters do not successfully exclude the proximal esophagus, which can lead to obstructive-type symptoms. Awareness of radial force, esophageal stricture composition, and proximal esophageal diameter must be known and understood for optimal stent tolerance.
Wang, Shousen; Ying, Jianbin; Wei, Liangfeng; Li, Shiqing; Jing, Junjie
2015-01-01
This study is to investigate the compensatory intracranial venous pathways in parasagittal meningiomas (PSM) patients by virtual reality technology. A total of 48 PSM patients (tumor group) and 20 patients with trigeminal neuralgia and hemifacial spasm but without intracranial venous diseases (control group) were enrolled. All patients underwent 3D CE-MRV examination. The 3D reconstructed images by virtual reality technology were used for assessment of diameter and number of intracranial veins, tumor location, venous sinus invasion degree and collateral circulation formation. Diameter of bridging veins in posterior 1/3 superior sagittal sinus (SSS) in tumor group was significantly smaller than that of the control group (P < 0.05). For tumors located in mid 1/3 SSS, diameter of bridging veins and vein of Labbé (VL) in posterior 1/3 SSS decreased significantly (P < 0.05). For tumors located in posterior 1/3 SSS, bridging vein number and transverse sinus (TS) diameter significantly decreased while superficial Sylvian vein (SSV) diameter increased significantly (P < 0.05). Compared with tumor in posterior 1/3 SSS subgroup, number of bridging veins in the tumor in mid 1/3 SSS subgroup increased significantly (P < 0.05). Compared with control group, only the bridging vein number in anterior 1/3 SSS segment in invasion Type 3-4 tumor subgroup decreased significantly (P < 0.05). Diameter of TS and bridging veins in posterior 1/3 SSS segment in sinus invasion Type 5-6 tumor subgroup decreased significantly (P < 0.05). Compared with control group, only the diameter of VL and TS of collateral circulation Grade 1 tumor subgroup decreased significantly (P < 0.05) while in Grade 3 tumor subgroup, TS diameter decreased and SSV diameter increased significantly (P < 0.05). The intracranial blood flow is mainly drained through SSV drainage after SSS occlusion by PSM.
Wang, Shousen; Ying, Jianbin; Wei, Liangfeng; Li, Shiqing; Jing, Junjie
2015-01-01
Objective: This study is to investigate the compensatory intracranial venous pathways in parasagittal meningiomas (PSM) patients by virtual reality technology. Methods: A total of 48 PSM patients (tumor group) and 20 patients with trigeminal neuralgia and hemifacial spasm but without intracranial venous diseases (control group) were enrolled. All patients underwent 3D CE-MRV examination. The 3D reconstructed images by virtual reality technology were used for assessment of diameter and number of intracranial veins, tumor location, venous sinus invasion degree and collateral circulation formation. Results: Diameter of bridging veins in posterior 1/3 superior sagittal sinus (SSS) in tumor group was significantly smaller than that of the control group (P < 0.05). For tumors located in mid 1/3 SSS, diameter of bridging veins and vein of Labbé (VL) in posterior 1/3 SSS decreased significantly (P < 0.05). For tumors located in posterior 1/3 SSS, bridging vein number and transverse sinus (TS) diameter significantly decreased while superficial Sylvian vein (SSV) diameter increased significantly (P < 0.05). Compared with tumor in posterior 1/3 SSS subgroup, number of bridging veins in the tumor in mid 1/3 SSS subgroup increased significantly (P < 0.05). Compared with control group, only the bridging vein number in anterior 1/3 SSS segment in invasion Type 3-4 tumor subgroup decreased significantly (P < 0.05). Diameter of TS and bridging veins in posterior 1/3 SSS segment in sinus invasion Type 5-6 tumor subgroup decreased significantly (P < 0.05). Compared with control group, only the diameter of VL and TS of collateral circulation Grade 1 tumor subgroup decreased significantly (P < 0.05) while in Grade 3 tumor subgroup, TS diameter decreased and SSV diameter increased significantly (P < 0.05). Conclusions: The intracranial blood flow is mainly drained through SSV drainage after SSS occlusion by PSM. PMID:26550184
[Aboveground architecture and biomass distribution of Quercus variabilis].
Yu, Bi-yun; Zhang, Wen-hui; Hu, Xiao-jing; Shen, Jia-peng; Zhen, Xue-yuan; Yang, Xiao-zhou
2015-08-01
The aboveground architecture, biomass and its allocation, and the relationship between architecture and biomass of Quercus variabilis of different diameter classes in Shangluo, south slope of Qinling Mountains were researched. The results showed that differences existed in the aboveground architecture and biomass allocation of Q. variabilis of different diameter classes. With the increase of diameter class, tree height, DBH, and crown width increased gradually. The average decline rate of each diameter class increased firstly then decreased. Q. variabilis overall bifurcation ratio and stepwise bifurcation ratio increased then declined. The specific leaf areas of Q. variabilis of all different diameter classes at vertical direction were 0.02-0.03, and the larger values of leaf mass ratio, LAI and leaf area ratio at vertical direction in diameter level I , II, III appeared in the middle and upper trunk, while in diameter level IV, V, VI, they appeared in the central trunk, with the increase of diameter class, there appeared two peaks in vertical direction, which located in the lower and upper trunk. The trunk biomass accounted for 71.8%-88.4% of Q. variabilis aboveground biomass, while the branch biomass accounted for 5.8%-19.6%, and the leaf biomass accounted for 4.2%-8.6%. With the increase of diameter class, stem biomass proportion of Q. variabilis decreased firstly then increased, while the branch and leaf biomass proportion showed a trend that increased at first then decreased, and then increased again. The aboveground biomass of Q. variabilis was significantly positively correlated to tree height, DBH, crown width and stepwise bifurcation ratio (R2:1), and positively related to the overall bifurcation ratio and stepwise bifurcation ratio (R3:2), but there was no significant correlation. Trunk biomass and total biomass aboveground were negatively related to the trunk decline rate, while branch biomass and leaf biomass were positively related to trunk decline rate, but their correlations were all not significant.
Morphing hull implementation for unmanned underwater vehicles
NASA Astrophysics Data System (ADS)
Miller, Timothy F.; Gandhi, Farhan; Rufino, Russell J.
2013-11-01
There has been much interest and work in the area of morphing aircraft since the 1980s. Morphing could also potentially benefit unmanned underwater vehicles (UUVs). The current paper envisions a UUV with an interior pressure hull and a variable diameter outer flexible hull with fuel stored in the annulus between, and presents a mechanism to realize diameter change of the outer hull. The outer hull diameter of UUVs designed for very long endurance/range could be progressively reduced as fuel was consumed, thereby reducing drag and further increasing endurance and range capability. Diameter morphing could also be advantageous for compact storage of UUVs. A prototype is fabricated to represent an axial section of such a morphing diameter UUV. Diameter change is achieved using eight morphing trusses arranged equidistant around the circumference of the representative interior rigid hull. Each morphing truss has a lower rail (attached to the rigid hull) and an upper rail with V-linkages between, at either ends of the rail. Horizontal motion of the feet of the V-linkages (sliding in the lower rail) results in vertical motion of the upper rail which in turn produces diameter change of the outer hull. For the prototype built and tested, a 63% increase in outer diameter from 12.75″ to 20.75″ was achieved. The introduction of a stretched latex representative flexible skin around the outer rails increased actuation force requirement and led to a propensity for the wheel-in-track sliders in the morphing truss to bind. It is anticipated that this could be overcome with higher precision manufacturing. In addition to symmetric actuation of the morphing trusses resulting in diameter change, the paper also shows that with asymmetric actuation the hull cross-section shape can be changed (for example, from a circular section for underwater operation to a V-section for surface operations).
Growth of modern branched columnar stromatolites in Lake Joyce, Antarctica.
Mackey, T J; Sumner, D Y; Hawes, I; Jungblut, A D; Andersen, D T
2015-07-01
Modern decimeter-scale columnar stromatolites from Lake Joyce, Antarctica, show a change in branching pattern during a period of lake level rise. Branching patterns correspond to a change in cyanobacterial community composition as preserved in authigenic calcite crystals. The transition in stromatolite morphology is preserved by mineralized layers that contain microfossils and cylindrical molds of cyanobacterial filaments. The molds are composed of two populations with different diameters. Large diameter molds (>2.8 μm) are abundant in calcite forming the oldest stromatolite layers, but are absent from younger layers. In contrast, <2.3 μm diameter molds are common in all stromatolites layers. Loss of large diameter molds corresponds to the transition from smooth-sided stromatolitic columns to branched and irregular columns. Mold diameters are similar to trichome diameters of the four most abundant living cyanobacteria morphotypes in Lake Joyce: Phormidium autumnale morphotypes have trichome diameters >3.5 μm, whereas Leptolyngbya antarctica, L. fragilis, and Pseudanabaena frigida morphotypes have diameters <2.3 μm. P. autumnale morphotypes were only common in mats at <12 m depth. Mats containing abundant P. autumnale morphotypes were smooth, whereas mats with few P. autumnale morphotypes contained small peaks and protruding bundles of filaments, suggesting that the absence of P. autumnale morphotypes allowed small-scale topography to develop on mats. Comparisons of living filaments and mold diameters suggest that P. autumnale morphotypes were present early in stromatolite growth, but disappeared from the community through time. We hypothesize that the mat-smoothing behavior of P. autumnale morphotypes inhibited nucleation of stromatolite branches. When P. autumnale morphotypes were excluded from the community, potentially reflecting a rise in lake level, short-wavelength roughness provided nuclei for stromatolite branches. This growth history provides a conceptual model for initiation of branched stromatolite growth resulting from a change in microbial community composition. © 2015 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Marchese, Anthony J.; Dryer, Fredrick L.; Choi, Mun Y.
1994-01-01
In order to develop an extensive envelope of test conditions for NASA's space-based Droplet Combustion Experiment (DCE) as well those droplet experiments which can be performed using a drop tower, the transient vaporization and combustion of methanol and n-heptane droplets were simulated using a recently developed fully time-dependent, spherically symmetric droplet combustion model. The transient vaporization of methanol and n-heptane was modeled to characterize the instantaneous gas phase composition surrounding the droplet prior to the introduction of an ignition source. The results for methanol/air showed that the entire gas phase surrounding a 2 mm methanol droplet deployed in zero-g .quickly falls outside the lean flammability limit. The gas phase surrounding an identically-sized n-heptane droplet, on the other hand, remains flammable. The combustion of methanol was then modeled considering a detailed gas phase chemical kinetic mechanism (168 steps, 26 species) and the effect of the dissolution of flame-generated water into the liquid droplet. These results were used to determine the critical ignition diameter required to achieve quasi-steady droplet combustion in a given oxidizing environment. For droplet diameters greater than the critical ignition diameter, the model predicted a finite diameter at which the flame would extinguish. These extinction diameters were found to vary significantly with initial droplet diameter. This phenomenon appears to be unique to the transient heat transfer, mass transfer and chemical kinetics of the system and thus has not been reported elsewhere to date. The extinction diameter was also shown to vary significantly with the liquid phase Lewis number since the amount of water present in the droplet at extinction is largely governed by the rate at which water is transported into the droplet via mass diffusion. Finally, the numerical results for n-heptane combustion were obtained using both 2 step and 96 step semi-emperical chemical kinetic mechanisms. Neither mechanism exhibited the variation of extinction diameter with initial diameter.
1985-02-20
Surface Cemennt/entonte Grout Rat 20/1 6" Diameter Bore "Ole 8 Foit B.G.S. Bentorito 4" Diameter POes" Schedle 409 Fee S.O.S.PVC Riser Pipe with...Casing with Locking Cap GRiser Pipe StickupGround Surface 2.2Fe Cement/BSentonite Grout Ratio 20/1 8" Diameter Bore Hole cv Ile- 3 Feet B.G.S...Ground Surface 4’. Ground Surface .0~ Cemtert/Bentonlte Grout Rat 20/1 8" Diamneter Bore Hole__ 4" Diameter Pl O Schedule 404 PVC Riser Pipe FetBGS
The effects of nanostructures on the mechanical and tribological properties of TiO2 nanotubes
NASA Astrophysics Data System (ADS)
Yoon, Yeoungchin; Park, Jeongwon
2018-04-01
TiO2 nanotubes were prepared by anodization on Ti substrates with a diameter variation of 30-100 nm, and the structure of the nanotubes were studied using x-ray diffraction and Raman spectroscopy, which confirmed the structure changes from the anatase phase to the rutile phase of TiO2 at a diameter below 50 nm. The tribological behaviors of TiO2 nanotubes were investigated with different diameters. The effectiveness of the rutile phase and the diameter size enhanced the frictional performance of TiO2 nanotubes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Yong-Ho; Maeng, Jwa-Young; Park, Dongho
2007-07-23
This letter reports a module for airborne particle classification, which consists of a micromachined three-stage virtual impactor for classifying airborne particles according to their size and a flow rate distributor for supplying the required flow rate to the virtual impactor. Dioctyl sebacate particles, 100-600 nm in diameter, and carbon particles, 0.6-10 {mu}m in diameter, were used for particle classification. The collection efficiency and cutoff diameter were examined. The measured cutoff diameters of the first, second, and third stages were 135 nm, 1.9 {mu}m, and 4.8 {mu}m, respectively.
The effects of nanostructures on the mechanical and tribological properties of TiO2 nanotubes.
Yoon, Yeoungchin; Park, Jeongwon
2018-04-20
TiO 2 nanotubes were prepared by anodization on Ti substrates with a diameter variation of 30-100 nm, and the structure of the nanotubes were studied using x-ray diffraction and Raman spectroscopy, which confirmed the structure changes from the anatase phase to the rutile phase of TiO 2 at a diameter below 50 nm. The tribological behaviors of TiO 2 nanotubes were investigated with different diameters. The effectiveness of the rutile phase and the diameter size enhanced the frictional performance of TiO 2 nanotubes.
Understanding the effect of carbon status on stem diameter variations
De Swaef, Tom; Driever, Steven M.; Van Meulebroek, Lieven; Vanhaecke, Lynn; Marcelis, Leo F. M.; Steppe, Kathy
2013-01-01
Background Carbon assimilation and leaf-to-fruit sugar transport are, along with plant water status, the driving mechanisms for fruit growth. An integrated comprehension of the plant water and carbon relationships is therefore essential to better understand water and dry matter accumulation. Variations in stem diameter result from an integrated response to plant water and carbon status and are as such a valuable source of information. Methods A mechanistic water flow and storage model was used to relate variations in stem diameter to phloem sugar loading and sugar concentration dynamics in tomato. The simulation results were compared with an independent model, simulating phloem sucrose loading at the leaf level based on photosynthesis and sugar metabolism kinetics and enabled a mechanistic interpretation of the ‘one common assimilate pool’ concept for tomato. Key Results Combining stem diameter variation measurements and mechanistic modelling allowed us to distinguish instantaneous dynamics in the plant water relations and gradual variations in plant carbon status. Additionally, the model combined with stem diameter measurements enabled prediction of dynamic variables which are difficult to measure in a continuous and non-destructive way, such as xylem water potential and phloem hydrostatic potential. Finally, dynamics in phloem sugar loading and sugar concentration were distilled from stem diameter variations. Conclusions Stem diameter variations, when used in mechanistic models, have great potential to continuously monitor and interpret plant water and carbon relations under natural growing conditions. PMID:23186836
Zanatta, Rayssa Ferreira; Barreto, Bruno de Castro Ferreira; Xavier, Tathy Aparecida; Versluis, Antheunis; Soares, Carlos José
2015-02-01
This study evaluated the influence of punch and base orifice diameters on push-out test results by means of finite element analysis (FEA). FEA was performed using 3D models of the push-out test with 3 base orifice diameters (2.5, 3.0, and 3.5 mm) and 3 punch diameters (0.5, 1.0, and 1.5 mm) using MARC/MENTAT (MSC.Software). The image of a cervical slice from a root restored with a fiberglass post was used to construct the models. The mechanical properties of dentin, post, and resin cement were obtained from the literature. Bases and punches were constructed as rigid bodies. A 10-N force was applied by the punch in the center of the post in a nonlinear contact analysis. Modified von Mises stress, maximum principal stress, as well as shear and normal stress components were calculated. Both punch and base orifice sizes influenced the stress distribution of the push-out test. Bases with larger diameters and punches with smaller diameters caused higher stress in dentin and at the dentin/cement interface. FEA showed that the diameter of the orifice base had a more significant influence on the stress distribution than did the punch diameter. For this reason, both factors should be taken into account during push-out experimental tests.
Determination of Shapes of Boattail Bodies of Revolution for Minimum Wave Drag
NASA Technical Reports Server (NTRS)
Adams, Mac C.
1951-01-01
By use of an approximate equation for the wave drag of slender bodies of revolution in a supersonic flow field, the optimum shapes of certain boattail bodies are determined for minimum wave drag. The properties of three specific families of bodies are determined, the first family consisting of bodies having a given length and base area and a contour passing through a prescribed point between the nose and base, the second family having fixed length, base area, and maximum area, and the third family having given length, volume, and base area. The method presented is easily generalized to determine minimum-wave-drag profile shapes which have contours that must pass through any prescribed number of points. According to linearized theory, the optimum profiles are found to have infinite slope at the nose but zero radius of curvature so that the bodies appear to have pointed noses, a zero slope at the body base, and no variation of wave drag with Mach number. For those bodies having a specified intermediate.diameter (that is, location and magnitude given), the maximum body diameter is shown to be larger, in general, than the specified diameter. It is also shown that, for bodies having a specified maximum diameter, the location of the maximum diameter is not arbitrary but is determined from the ratio of base diameter to maximum diameter.
MARTINS, Renata de Castro; BAHIA, Maria Guiomar de Azevedo; BUONO, Vicente Tadeu Lopes
2010-01-01
Objective This study identified which regions of ProTaper instruments work during curved root canal instrumentation. Material and methods Twelve ProTaper instruments of each type, S1, S2, F1, and F2, were assessed morphometrically by measuring tip angle, tip length, tip diameter, length of each pitch along the cutting blades, and instrument diameter at each millimeter from the tip. Curved canals in resin blocks were explored with manual stainless steel files and prepared with ProTaper instruments until the apical end following four distinct sequences of instrumentation: S1; S1 and S2; S1, S2, and F1; S1, S2, F1, and F2. Image analysis was employed for measuring canal diameters. The diameters of the canals and diameters of the instruments were compared. Data were analyzed by one-way ANOVA and Tukey’s test. Results No statistically significant difference was found between the canals and instrument diameters (p>0.05). The largest diameters in the end-point of the instrumented canals were obtained with F1 and F2 instruments and in the initial and middle thirds with S1 and S2 instruments. Conclusions All instruments worked at the tip and along their cutting blades, being susceptible to fail by torsion, fatigue, or the combination of these two mechanisms. PMID:20379681
NASA Astrophysics Data System (ADS)
Kinoshita, Shunichi; Eder, Wolfgang; Wöger, Julia; Hohenegger, Johann; Briguglio, Antonino
2017-04-01
Investigations on Palaeonummulites venosus using the natural laboratory approach for determining chamber building rate, test diameter increase rate, reproduction time and longevity is based on the decomposition of monthly obtained frequency distributions based on chamber number and test diameter into normal-distributed components. The shift of the component parameters 'mean' and 'standard deviation' during the investigation period of 15 months was used to calculate Michaelis-Menten functions applied to estimate the averaged chamber building rate and diameter increase rate under natural conditions. The individual dates of birth were estimated using the inverse averaged chamber building rate and the inverse diameter increase rate fitted by the individual chamber number or the individual test diameter at the sampling date. Distributions of frequencies and densities (i.e. frequency divided by sediment weight) based on chamber building rate and diameter increase rate resulted both in a continuous reproduction through the year with two peaks, the stronger in May /June determined as the beginning of the summer generation (generation1) and the weaker in November determined as the beginning of the winter generation (generation 2). This reproduction scheme explains the existence of small and large specimens in the same sample. Longevity, calculated as the maximum difference in days between the individual's birth date and the sampling date seems to be round about one year, obtained by both estimations based on the chamber building rate and the diameter increase rate.
Lu, Ying-juan; Chang, Shao-hai; Ye, Jian-tao; Ye, Yu-shan; Yu, Yan-song
2015-01-01
Stress on the bone surrounding dental micro-implants affects implant success. To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm.
Lu, Ying-juan; Chang, Shao-hai; Ye, Jian-tao; Ye, Yu-shan; Yu, Yan-song
2015-01-01
Background Stress on the bone surrounding dental micro-implants affects implant success. Purpose To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. Materials and Methods Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. Results The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. Conclusion When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm. PMID:26659581
Wang, Guang-zhi; Li, Wei-guang; He, Wen-jie; Han, Hong-da; Ding, Chi; Ma, Xiao-na; Qu, Yan-ming
2006-10-01
By means of immobilizing five kinds of activated carbon, we studied the influence between the chief activated carbon property items and immobilized bioactivated carbon (IBAC) purification effect with the correlation analysis. The result shows that the activated carbon property items which the correlation coefficient is up 0.7 include molasses, abrasion number, hardness, tannin, uniform coefficient, mean particle diameter and effective particle diameter; the activated carbon property items which the correlation coefficient is up 0.5 include pH, iodine, butane and tetrachloride. In succession, the partial correlation analysis shows that activated carbon property items mostly influencing on IBAC purification effect include molasses, hardness, abrasion number, uniform coefficient, mean particle diameter and effective particle diameter. The causation of these property items bringing influence on IBAC purification is that the activated carbon holes distribution (representative activated carbon property item is molasses) provides inhabitable location and adjust food for the dominance bacteria; the mechanical resist-crash property of activated carbon (representative activated carbon property items: abrasion number and hardness) have influence on the stability of biofilm; and the particle diameter size and distribution of activated carbon (representative activated carbon property items: uniform coefficient, mean particle diameter and effective particle diameter) can directly affect the force of water in IBAC filter bed, which brings influence on the dominance bacteria immobilizing on activated carbon.
Pabari, Ritesh M; Ramtoola, Zebunnissa
2012-07-01
A two factor, three level (3(2)) face centred, central composite design (CCD) was applied to investigate the main and interaction effects of tablet diameter and compression force (CF) on hardness, disintegration time (DT) and porosity of mannitol based orodispersible tablets (ODTs). Tablet diameters of 10, 13 and 15 mm, and CF of 10, 15 and 20 kN were studied. Results of multiple linear regression analysis show that both the tablet diameter and CF influence tablet characteristics. A negative value of regression coefficient for tablet diameter showed an inverse relationship with hardness and DT. A positive value of regression coefficient for CF indicated an increase in hardness and DT with increasing CF as a result of the decrease in tablet porosity. Interestingly, at the larger tablet diameter of 15 mm, while hardness increased and porosity decreased with an increase in CF, the DT was resistant to change. The optimised combination was a tablet of 15 mm diameter compressed at 15 kN showing a rapid DT of 37.7s and high hardness of 71.4N. Using these parameters, ODTs containing ibuprofen showed no significant change in DT (ANOVA; p>0.05) irrespective of the hydrophobicity of the ibuprofen. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rana, Parvez; Vauhkonen, Jari; Junttila, Virpi; Hou, Zhengyang; Gautam, Basanta; Cawkwell, Fiona; Tokola, Timo
2017-12-01
Large-diameter trees (taking DBH > 30 cm to define large trees) dominate the dynamics, function and structure of a forest ecosystem. The aim here was to employ sparse airborne laser scanning (ALS) data with a mean point density of 0.8 m-2 and the non-parametric k-most similar neighbour (k-MSN) to predict tree diameter at breast height (DBH) distributions in a subtropical forest in southern Nepal. The specific objectives were: (1) to evaluate the accuracy of the large-tree fraction of the diameter distribution; and (2) to assess the effect of the number of training areas (sample size, n) on the accuracy of the predicted tree diameter distribution. Comparison of the predicted distributions with empirical ones indicated that the large tree diameter distribution can be derived in a mixed species forest with a RMSE% of 66% and a bias% of -1.33%. It was also feasible to downsize the sample size without losing the interpretability capacity of the model. For large-diameter trees, even a reduction of half of the training plots (n = 250), giving a marginal increase in the RMSE% (1.12-1.97%) was reported compared with the original training plots (n = 500). To be consistent with these outcomes, the sample areas should capture the entire range of spatial and feature variability in order to reduce the occurrence of error.
NASA Astrophysics Data System (ADS)
White, Bradley W.; Tarver, Craig M.
2017-01-01
It has long been known that detonating single crystals of solid explosives have much larger failure diameters than those of heterogeneous charges of the same explosive pressed or cast to 98 - 99% theoretical maximum density (TMD). In 1957, Holland et al. demonstrated that PETN single crystals have failure diameters of about 8 mm, whereas heterogeneous PETN charges have failure diameters of less than 0.5 mm. Recently, Fedorov et al. quantitatively determined nanosecond time resolved detonation reaction zone profiles of single crystals of PETN and HMX by measuring the interface particle velocity histories of the detonating crystals and LiF windows using a PDV system. The measured reaction zone time durations for PETN and HMX single crystal detonations were approximately 100 and 260 nanoseconds, respectively. These experiments provided the necessary data to develop Ignition and Growth (I&G) reactive flow model parameters for the single crystal detonation reaction zones. Using these parameters, the calculated unconfined failure diameter of a PETN single crystal was 7.5 +/- 0.5 mm, close to the 8 mm experimental value. The calculated failure diameter of an unconfined HMX single crystal was 15 +/- 1 mm. The unconfined failure diameter of an HMX single crystal has not yet been determined precisely, but Fedorov et al. detonated 14 mm diameter crystals confined by detonating a HMX-based plastic bonded explosive (PBX) without initially overdriving the HMX crystals.
Flue gas adsorption by single-wall carbon nanotubes: A Monte Carlo study.
Romero-Hermida, M I; Romero-Enrique, J M; Morales-Flórez, V; Esquivias, L
2016-08-21
Adsorption of flue gases by single-wall carbon nanotubes (SWCNT) has been studied by means of Monte Carlo simulations. The flue gas is modeled as a ternary mixture of N2, CO2, and O2, emulating realistic compositions of the emissions from power plants. The adsorbed flue gas is in equilibrium with a bulk gas characterized by temperature T, pressure p, and mixture composition. We have considered different SWCNTs with different chiralities and diameters in a range between 7 and 20 Å. Our results show that the CO2 adsorption properties depend mainly on the bulk flue gas thermodynamic conditions and the SWCNT diameter. Narrow SWCNTs with diameter around 7 Å show high CO2 adsorption capacity and selectivity, but they decrease abruptly as the SWCNT diameter is increased. For wide SWCNT, CO2 adsorption capacity and selectivity, much smaller in value than for the narrow case, decrease mildly with the SWCNT diameter. In the intermediate range of SWCNT diameters, the CO2 adsorption properties may show a peculiar behavior, which depend strongly on the bulk flue gas conditions. Thus, for high bulk CO2 concentrations and low temperatures, the CO2 adsorption capacity remains high in a wide range of SWCNT diameters, although the corresponding selectivity is moderate. We correlate these findings with the microscopic structure of the adsorbed gas inside the SWCNTs.
NASA Astrophysics Data System (ADS)
Iguchi, Naoki; Lee, Hye Eun; Yoon, Won Duk; Kim, Suam
2010-06-01
This study investigated the sexual maturation process, release of spermatozoa or eggs and oocyte diameter of the rhizostomid medusae Nemopilema nomurai using samples collected from August 2006 to June 2008 from the waters around Korea and Japan, including peripheral areas outside the species’ usual habitat. Immature medusae were observed from June to October only in the western sector of the study area. The onset of spermatozoa and egg release occurred in September and October, respectively, and peaked in December and January. Medusae migrated eastward from source areas with the Tsushima Warm Current, where they formed gametes and spawned. Peak position and maximum oocyte diameter increased as the gonads developed according to the size-frequency distribution of oocytes. No fertilized eggs or embryos were found in the gonads. The correlation was analyzed with bell diameter, maximum oocyte diameter, sampling date, surface water temperature and gonad color to estimate which environmental factors and maturation indices were related to the maturation stage of females. Maturation stage correlated well with maximum oocyte diameter, which correlated negatively with surface water temperature. There was no significant correlation between bell diameter and maturation stage. Therefore, bell diameter was inappropriate for determining maturation index. Sex could not be distinguished clearly by gonad color. However, light pink gonads were more prevalent in males and various deep colors such as orange and brown were more frequent in female medusae.
Automated estimation of abdominal effective diameter for body size normalization of CT dose.
Cheng, Phillip M
2013-06-01
Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-11
... DEPARTMENT OF COMMERCE International Trade Administration [A-588-850] Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 4\\1/2\\ Inches) From Japan: Extension of... administrative review of the antidumping duty order on certain large diameter carbon and alloy seamless standard...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-24
... facilities would include: (1) Three 35-kilowatt (kW), 5-meter-diameter axial flow Kinetic System turbine...; (2) nine additional 5-meter-diameter axial flow Kinetic System turbine generator units mounted on...-meter-diameter axial flow Kinetic System turbine generator units mounted on six triframe mounts, with a...
A new algorithm for stand table projection models.
Quang V. Cao; V. Clark Baldwin
1999-01-01
The constrained least squares method is proposed as an algorithm for projecting stand tables through time. This method consists of three steps: (1) predict survival in each diameter class, (2) predict diameter growth, and (3) use the least squares approach to adjust the stand table to satisfy the constraints of future survival, average diameter, and stand basal area....
Diameter growth of upland oaks after thinning
Donald E. Hilt
1979-01-01
Diameter growth rates of the 40 largest trees per acre on 154 permanent plots in Kentucky, Ohio, Missouri, and Iowa were analyzed to determine the effects of thinning in upland oak stands. The plots were established over a wide range of stocking levels, stand age, and site conditions. Thinning resulted in increased diameter growth of the residual trees, regardless of...
Fei Pan; Han-Sup Han; Leonard R. Johnson; William J. Elliot
2008-01-01
Dense, small-diameter stands generally require thinning from below to improve fire-tolerance. The resulting forest biomass can be used for energy production. The cost of harvesting, processing, and transporting small-diameter trees often exceeds revenues due to high costs associated with harvesting and transportation and low market values for forest biomass....
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-17
... conditions, and prescriptions. k. Deadline for filing responsive documents: Due to the small size of the... proposed 80-foot-long, 16-inch-diameter intake pipe; (3) a proposed 18- foot by 18-foot powerhouse..., 50-foot discharge pipe, connecting to existing 42-inch diameter and 10- inch diameter pipes conveying...
Options for small-diameter hardwood utilization: past and present
Matthew S. Bumgardner; Bruce G. Hansen; Albert T. Schuler; Philip A. Araman
2000-01-01
Effective and maximum value use of small-diameter hardwood timber has long been of interest to forest managers and researchers. In addition to being a significant component of the standing forest base, small-diameter hardwoods often are available after thinning or other tending operations. Although the use of this material is important to achieving healthy and...
Evaluation of roll-off trailers in small-diameter applications
Bob Rummer; John Klepac
2003-01-01
Concern about wildfire in overstocked forests of the western U.S. has led to increased emphasis on extraction of small-diameter material. Removing this material improves forest health, reduces fuel loading, and may generate value that can be used to offset the costs of operation. However, the cost of small-diameter operations (both in-woods and secondary processing)...
Small-diameter success stories II
Jean Livingston
2006-01-01
Many of our national forests are in critical need of restoration. These forests are dense, with an abundance of small-diameter, tightly spaced trees and underbrush that can contribute to the rapid growth of fire. If economic and value-added uses for this small-diameter and unmerchantable material can be found, forest restoration costs could be offset and catastrophic...
Options for Small-Diameter Hardwood Utilization: Past and Present
Matthew S. Bumgardner; Bruce G. Hansen; Albert T. Schuler; Philip A. Araman; Philip A. Araman
2001-01-01
Effective and maximum value use of small-diameter hardwood timber has long been of interest to forest managers and researchers. In addition to being a significant component of the standing forest base, small-diameter hardwoods often are available after thinning or other tending operations. Although the use of this material is important to achieving healthy and...
Understory response following varying levels of overstory removal in mixed conifer stands
Fabian C.C. Uzoh; Leroy K. Dolph; John R. Anstead
1997-01-01
Diameter growth rates of understory trees were measured for periods both before and after overstory removal on six study areas in northern California. All the species responded with increased diameter growth after adjusting to their new environments. Linear regression equations that predict post treatment diameter growth increment of the residual trees are presented...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-11
...-inch-diameter pipeline (TL-610-Extension 1), associated with a new valve at DTI's existing Elk Run Gate...-inch-diameter pipeline (TL-614) in Potter County, Pennsylvania; Installation of about 900 feet of new 24-inch-diameter pipeline (TL-615) and a new meter station in Greene County, Pennsylvania; Upgrades...
Survival and growth of black walnut families after 7 years in West Virginia
G. W. Wendel; Donald E. Dorn; Donald E. Dorn
1985-01-01
Average survival, 7-year stem diameter, and stem diameter growth differed significantly among 34 black walnut families planted in West Virginia. Average total height, height growth, and diameter at breast height were not significantly different among families. Families were from seed collected in West Virginia, Pennsylvania, North Carolina, and Tennessee. The 7-year...
15 CFR 241.7 - Tolerances to be allowed.
Code of Federal Regulations, 2013 CFR
2013-01-01
... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...
15 CFR 241.7 - Tolerances to be allowed.
Code of Federal Regulations, 2011 CFR
2011-01-01
... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...
15 CFR 241.7 - Tolerances to be allowed.
Code of Federal Regulations, 2014 CFR
2014-01-01
... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...
15 CFR 241.7 - Tolerances to be allowed.
Code of Federal Regulations, 2012 CFR
2012-01-01
... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...
Long-term structural change in uneven-aged northern hardwoods
William B. Leak
1996-01-01
The diameter distributions of 10 previously unmanaged northern hardwood stands on the Bartlett Experimental Forest in New Hampshire were analyzed to determine changes over a 35 yr period since a single cutting by the diameter-limit or single-tree selection methods. The diameter distribution of an uncut old-growth stand (the Bowl) provided a comparison. The cuttings...
50 CFR 665.165 - Size restrictions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... its base to its most distal extremity. The stem diameter of a living coral specimen shall be determined by measuring the greatest diameter of the stem at a point no less than 1 inch (2.54 cm) from the... from any precious coral permit area must have attained either a minimum stem diameter of 1 inch (2.54...
50 CFR 665.265 - Size restrictions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... its base to its most distal extremity. The stem diameter of a living coral specimen shall be determined by measuring the greatest diameter of the stem at a point no less than 1 inch (2.54 cm) from the... from any precious coral permit area must have attained either a minimum stem diameter of 1 inch (2.54...
Long-term assessment of financial maturity, diameter-limit selection in the central Appalachians
Thomas M. Schuler; David W. McGill
2007-01-01
Financial maturity, diameter-limit (FMDL) selection was proposed more than three decades ago as a replacement for diameter-limit cutting. FMDL incorporates financial maturity guidelines for individual trees, high-priority removal of poorquality trees, and guidelines for residual basal area. We provide the first long-term assessment of this practice after more than...
Diameter Growth of Southern Bottomland Hardwoods
Henry Bull
1945-01-01
There is very little published information on average rates of diameter growth of southern bottomland hardwoods. Probably the best information of this kind is given by Winters, Putnam, and Eldredge,2 who summarize forest survey data on average rates of diameter growth for 4 size classes and 20 species or species groups (including pine and cyress), and for all species...
Board-Foot and Diameter Growth of Yellow-Poplar After Thinning
Donald E. Beck; Lino Della-Bianca
1975-01-01
Board-foot growth and yield of thinned yellow-poplar stands (Liriodendron tulipifera L.)is related to age, site index, residual basal area, and residual quadratic mean stand diameter after thinning. Diameter growth of individual trees is increased considerably by thinning. Equations describing growth and yield are based on data from 141 natura1 yellow-poplar stands in...
Height diameter relations of maple street trees
David J. Nowak
1990-01-01
Height and diameter measurements were taken for silver, sugar and Norway maple street trees in Rochester and Syracuse, New York. Mature silver maples proved to be the tallest of the three species. Average sugar maple height was consistently taller than Norway maple height until diameters reached 28 inches. Average mature tree height for all three species level off in...
Evaluating growth performance of young stands
A. L. Roe; R. E. Benson
1966-01-01
A simple procedure for evaluating the diameter growth of young stands in relation to potential growth is described. A comparison technique is developed which contrasts relative diameter of crop trees to the relative diameter growth of the last decade to show the condition and trend of growth in the stand. The method is objective, easy to use, and has several...
Diameter Growth, Survival, and Volume Estimates for Missouri Trees
Stephen R. Shifley; W. Brad Smith
1982-01-01
Measurements of more than 20,000 Missouri trees were summarized by species and diameter class into tables of mean annual diameter growth, annual probability of survival, net cubic foot volume, and net board foot volume. In the absence of better forecasting techniques, this information can be utilized to project short-term changes for Missouri trees, inventory plots,...
Three-dimensional growth dynamics of the liver in the human fetus.
Szpinda, Michał; Paruszewska-Achtel, Monika; Woźniak, Alina; Badura, Mateusz; Mila-Kierzenkowska, Celestyna; Wiśniewski, Marcin
2015-07-01
The fetal liver is indubitably the earliest and the most severely affected organ by abnormal fetal growth. The size of the fetal liver assessed by three-dimensional ultrasonography is indispensable in determining the status of fetal growth, nutrition and maturity, and in the early recognition and monitoring fetal micro- and macrosomias. The aim of the present study was to measure the human fetal liver length, transverse and sagittal diameters to establish their age-specific reference intervals, the 3rd, 10th, 50th, 90th, and 97th smoothed centile curves, and the relative growth of the liver calculated for the 50th centile. Using anatomical, digital (NIS-Elements AR 3.0, Nikon) and statistical methods (one-way ANOVA test for paired data and post hoc RIR Tukey test, Shapiro-Wilk test, Fisher's test, Student's t test, the Altman-Chitty method), length, transverse and sagittal diameters of the liver for the 3rd, 10th, 50th, 90th, and 97th centiles were assessed in 69 human fetuses of both sexes (32 males and 37 females) aged 18-30 weeks, derived from spontaneous abortions or stillbirths. No male-female differences (P > 0.05) concerning the three parameters studied were found. During the study period, the fetal liver increased tri-dimensionally: in length from 19.51 ± 1.02 to 39.65 ± 7.05 mm, in transverse diameter from 29.44 ± 3.73 to 53.13 ± 5.31 mm, and in sagittal diameter from 22.97 ± 3.79 to 43.22 ± 5.49 mm. The natural logarithmic models were found to fit the data with gestational age (P < 0.001) in the following five cutoff points: 3rd, 10th, 50th, 90th and 97th centiles. The values of liver parameters in relation to gestational age in weeks were calculated by the following logarithmic regressions: y = -82.778 + 35.752 × ln(age) ± Z × (-2.778 + 0.308 × age) for liver length, y = -123.06 + 52.668 × ln(age) ± Z × (3.156 + 0.049 × age) for liver transverse diameter, and y = -108.94 + 46.052 × ln(age) ± Z × (-0.541 + 0.188 × age) for liver sagittal diameter. For the 50th centile, at the range of 18-30 weeks, the growth rates per week were gradually decreasing from 1.93 to 1.21 mm for length, from 2.85 to 1.79 mm for transverse diameter, and from 2.49 to 1.56 mm for sagittal diameter of the liver (P < 0.05). During the study period both the length-to-transverse diameter ratio and the sagittal-to-transverse diameter ratio of the liver changed little, attaining the values of 0.71 ± 0.11 and 0.87 ± 0.12, respectively. The fetal liver does not reveal sex differences in its length, transverse and sagittal diameters. The fetal liver length, transverse and sagittal diameters grow logarithmically. The regression equations for the estimation of the mean and standard deviation of liver length, transverse and sagittal diameters allow for calculating any desired centiles according to gestational age. The three-dimensional evolution of the fetal liver follows proportionately. The age-specific reference intervals for evolving liver length, transverse and sagittal diameters constitute the normative values of potential relevance in monitoring normal fetal development and screening for disturbances in fetal growth.
NASA Astrophysics Data System (ADS)
Posluk, Evren; Oğul, Kenan
2015-04-01
2. stage (İnönü-Köseköy) of Ankara-İstanbul High-Speed Train Project (YHT) is 150 km-long and includes 25 tunnels with total length of nearly 58 km. The 7765 m-long part of these tunnels between Bozüyük and Bilecik was excavated in the metamorphic units of Pazarcık Structural Complex which have different thicknesses and form horizontal and vertical transitions to each other. The folded weak graphitic schists with thin schistosity planes affect the tunnel support performance negatively. In this study, the tunnels with 13.5, 8.2 and 4 m-diameters excavated in the weak-very weak graphitic schists by the conventional methods and the reasons of the problems (overbreak, deformation higher than estimated, wreckage etc.) are examined. The most common problems in the tunnel construction are overbreak and deformations higher than estimated before. Upsizing the fore-polling diameters, injection with pressure and carving the tunnel face were the first applied methods for decreasing the overbreak in the wide tunnels. Although these methods decreased the overbreak, the deformations in the tunnel couldn't be prevented. In this context, the data derived from the rod and tape extensometers was examined, the elastic and plastic zones were determined, the creep behaviour was locally observed on the support elements during 65 days. Also the mass parameters (GSI, weight per unit of volume, uniaxial compression, modulus of elasticity, modulus of deformation etc.) of the weak-very weak rocks were evaluated again. By the help of the compiled data it was determined that when the tunnel diameter increases, the deformation and overbreak increase. For example, while there are approximately two overbreaks at each 100 m in a 4 m-diameter tunnel, it is three in a 8.2 m-diameter tunnel and six in a 13.5 m-diameter tunnel. The deformations were estimated as 8 cm in a 4 m-diameter tunnel, 15 cm in a 8.2 m-diameter tunnel, 20 cm in a 13.5 m-diameter tunnel. However they are respectively 7.1, 15.8 and 31.9 cm. On the purpose of decreasing the stability problems during excavation, it was concluded that the excavation should proceed step by step as long as the diameter increases and the time connected rock mass behaviour should be examined in order to determine the weak-very weak rock mass support system.
Measurements of stem diameter: implications for individual- and stand-level errors.
Paul, Keryn I; Larmour, John S; Roxburgh, Stephen H; England, Jacqueline R; Davies, Micah J; Luck, Hamish D
2017-08-01
Stem diameter is one of the most common measurements made to assess the growth of woody vegetation, and the commercial and environmental benefits that it provides (e.g. wood or biomass products, carbon sequestration, landscape remediation). Yet inconsistency in its measurement is a continuing source of error in estimates of stand-scale measures such as basal area, biomass, and volume. Here we assessed errors in stem diameter measurement through repeated measurements of individual trees and shrubs of varying size and form (i.e. single- and multi-stemmed) across a range of contrasting stands, from complex mixed-species plantings to commercial single-species plantations. We compared a standard diameter tape with a Stepped Diameter Gauge (SDG) for time efficiency and measurement error. Measurement errors in diameter were slightly (but significantly) influenced by size and form of the tree or shrub, and stem height at which the measurement was made. Compared to standard tape measurement, the mean systematic error with SDG measurement was only -0.17 cm, but varied between -0.10 and -0.52 cm. Similarly, random error was relatively large, with standard deviations (and percentage coefficients of variation) averaging only 0.36 cm (and 3.8%), but varying between 0.14 and 0.61 cm (and 1.9 and 7.1%). However, at the stand scale, sampling errors (i.e. how well individual trees or shrubs selected for measurement of diameter represented the true stand population in terms of the average and distribution of diameter) generally had at least a tenfold greater influence on random errors in basal area estimates than errors in diameter measurements. This supports the use of diameter measurement tools that have high efficiency, such as the SDG. Use of the SDG almost halved the time required for measurements compared to the diameter tape. Based on these findings, recommendations include the following: (i) use of a tape to maximise accuracy when developing allometric models, or when monitoring relatively small changes in permanent sample plots (e.g. National Forest Inventories), noting that care is required in irregular-shaped, large-single-stemmed individuals, and (ii) use of a SDG to maximise efficiency when using inventory methods to assess basal area, and hence biomass or wood volume, at the stand scale (i.e. in studies of impacts of management or site quality) where there are budgetary constraints, noting the importance of sufficient sample sizes to ensure that the population sampled represents the true population.
PHYSICAL PROPERTIES OF LARGE AND SMALL GRANULES IN SOLAR QUIET REGIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu Daren; Xie Zongxia; Hu Qinghua
The normal mode observations of seven quiet regions obtained by the Hinode spacecraft are analyzed to study the physical properties of granules. An artificial intelligence technique is introduced to automatically find the spatial distribution of granules in feature spaces. In this work, we investigate the dependence of granular continuum intensity, mean Doppler velocity, and magnetic fields on granular diameter. We recognized 71,538 granules by an automatic segmentation technique and then extracted five properties: diameter, continuum intensity, Doppler velocity, and longitudinal and transverse magnetic flux density to describe the granules. To automatically explore the intrinsic structures of the granules in themore » five-dimensional parameter space, the X-means clustering algorithm and one-rule classifier are introduced to define the rules for classifying the granules. It is found that diameter is a dominating parameter in classifying the granules and two families of granules are derived: small granules with diameters smaller than 1.''44, and large granules with diameters larger than 1.''44. Based on statistical analysis of the detected granules, the following results are derived: (1) the averages of diameter, continuum intensity, and Doppler velocity in the upward direction of large granules are larger than those of small granules; (2) the averages of absolute longitudinal, transverse, and unsigned flux density of large granules are smaller than those of small granules; (3) for small granules, the average of continuum intensity increases with their diameters, while the averages of Doppler velocity, transverse, absolute longitudinal, and unsigned magnetic flux density decrease with their diameters. However, the mean properties of large granules are stable; (4) the intensity distributions of all granules and small granules do not satisfy Gaussian distribution, while that of large granules almost agrees with normal distribution with a peak at 1.04 I{sub 0}.« less
Boyemba, Faustin; Lewis, Simon; Nabahungu, Nsharwasi Léon; Calders, Kim; Zapfack, Louis; Riera, Bernard; Balegamire, Clarisse; Cuni-Sanchez, Aida
2017-01-01
Tropical montane forests provide an important natural laboratory to test ecological theory. While it is well-known that some aspects of forest structure change with altitude, little is known on the effects of altitude on above ground biomass (AGB), particularly with regard to changing height-diameter allometry. To address this we investigate (1) the effects of altitude on height-diameter allometry, (2) how different height-diameter allometric models affect above ground biomass estimates; and (3) how other forest structural, taxonomic and environmental attributes affect above ground biomass using 30 permanent sample plots (1-ha; all trees ≥ 10 cm diameter measured) established between 1250 and 2600 m asl in Kahuzi Biega National Park in eastern Democratic Republic of Congo. Forest structure and species composition differed with increasing altitude, with four forest types identified. Different height-diameter allometric models performed better with the different forest types, as trees got smaller with increasing altitude. Above ground biomass ranged from 168 to 290 Mg ha-1, but there were no significant differences in AGB between forests types, as tree size decreased but stem density increased with increasing altitude. Forest structure had greater effects on above ground biomass than forest diversity. Soil attributes (K and acidity, pH) also significantly affected above ground biomass. Results show how forest structural, taxonomic and environmental attributes affect above ground biomass in African tropical montane forests. They particularly highlight that the use of regional height-diameter models introduces significant biases in above ground biomass estimates, and that different height-diameter models might be preferred for different forest types, and these should be considered in future studies. PMID:28617841
Jarque-Bou, N; Gracia-Ibáñez, V; Sancho-Bru, J L; Vergara, M; Pérez-González, A; Andrés, F J
2016-09-01
The kinematic analysis of human grasping is challenging because of the high number of degrees of freedom involved. The use of principal component and factorial analyses is proposed in the present study to reduce the hand kinematics dimensionality in the analysis of posture for ergonomic purposes, allowing for a comprehensive study without losing accuracy while also enabling velocity and acceleration analyses to be performed. A laboratory study was designed to analyse the effect of weight and diameter in the grasping posture for cylinders. This study measured the hand posture from six subjects when transporting cylinders of different weights and diameters with precision and power grasps. The hand posture was measured using a Vicon(®) motion-tracking system, and the principal component analysis was applied to reduce the kinematics dimensionality. Different ANOVAs were performed on the reduced kinematic variables to check the effect of weight and diameter of the cylinders, as well as that of the subject. The results show that the original twenty-three degrees of freedom of the hand were reduced to five, which were identified as digit arching, closeness, palmar arching, finger adduction and thumb opposition. Both cylinder diameter and weight significantly affected the precision grasping posture: diameter affects closeness, palmar arching and opposition, while weight affects digit arching, palmar arching and closeness. The power-grasping posture was mainly affected by the cylinder diameter, through digit arching, closeness and opposition. The grasping posture was largely affected by the subject factor and this effect couldn't be attributed only to hand size. In conclusion, this kinematic reduction allowed identifying the effect of the diameter and weight of the cylinders in a comprehensive way, being diameter more important than weight. Copyright © 2016 Elsevier Ltd. All rights reserved.
Janson, Christopher M; Patel, Akash R; Bonney, William J; Smoots, Karen; Shah, Maully J
2014-01-21
This study aimed to investigate the impact of lead diameter and design on implantable cardioverter-defibrillator (ICD) lead survival in children and young adults. Recent reports have called attention to high rates of lead failure in adults with small-diameter ICD leads, but data in the pediatric population is limited. We reviewed lead performance in consecutive subjects ≤30 years with transvenous right ventricular ICD leads implanted at our center between January 1995 and October 2011. Lead failure was defined as fracture, perforation, or sensing failure necessitating revision. A total of 120 ICD leads were implanted in 101 patients at a mean age of 15.5 ± 4.9 years. There were 47 small-diameter (≤8-F) and 73 standard-diameter (>8-F) leads. During a median follow-up of 28.7 months (interquartile range: 14.4 to 59.2 months), there were 25 lead failures (21% prevalence), with an incidence of 5.6%/year (95% confidence interval: 3.4 to 7.8). Sprint Fidelis (SF) (Medtronic, Inc., Minneapolis, Minnesota) leads had lower 3-year (69% vs. 92%, p < 0.01) and 5-year (44% vs. 86%, p < 0.01) survival probabilities than standard-diameter leads. In multivariate Cox regression, SF design conferred the greatest hazard ratio for lead failure (hazard ratio: 4.42, 95% confidence interval: 1.73 to 11.29, p < 0.01). Age and linear growth were not significantly associated with lead failure. In this single-center pediatric study that evaluated lead diameter, lead design, and patient factors, the SF design conferred the highest risk of lead failure, suggesting that design rather than diameter is the critical issue in ICD lead performance. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Role of macular hole angle in macular hole closure.
Chhablani, Jay; Khodani, Mitali; Hussein, Abdullah; Bondalapati, Sailaja; Rao, Harsha B; Narayanan, Raja; Sudhalkar, Aditya
2015-12-01
To evaluate correlation of various spectral-domain optical coherence tomography (SD-OCT) parameters including macular hole angle as well as various indices with anatomical and visual outcomes after idiopathic macular hole repair surgery. Retrospective study of 137 eyes of 137 patients who underwent idiopathic macular hole repair surgery between January 2008 and January 2014 was performed. Various qualitative parameters such as presence of vitreomacular traction, epiretinal membrane and cystic edges at the macular hole as well as quantitative parameters such as maximum diameter on the apex of the hole, minimum diameter between edges, nasal and temporal vertical height, longest base diameter and macular hole angle between the retinal edge and the retinal pigment epithelium were noted. Indices including hole form factor, Macular Hole Index (MHI), Diameter Hole Index and Tractional Hole Index (THI) were calculated. Univariate and multivariate regression analysis was performed separately for final visual acuity (VA) and type of closure as dependent variable in relation to SD-OCT parameters as independent variables. On multivariate regression only minimum diameter between edges (p≤0.01) and longest base diameter (p≤0.03) were correlated significantly with both, type 1 closure and final VA. Among the indices, significant correlation of MHI (p=0.009) was noted with type of closure and that of THI with final VA (p=0.017). Our study shows no significant correlation between macular hole angle and hole closure. Minimum diameter between the edges and longest diameter of the hole are best predictors of hole closure and postoperative VA. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Xu, Hongjuan; Weber, Stephen G.
2006-01-01
A post-column reactor consisting of a simple open tube (Capillary Taylor Reactor) affects the performance of a capillary LC in two ways: stealing pressure from the column and adding band spreading. The former is a problem for very small radius reactors, while the latter shows itself for large reactor diameters. We derived an equation that defines the observed number of theoretical plates (Nobs) taking into account the two effects stated above. Making some assumptions and asserting certain conditions led to a final equation with a limited number of variables, namely chromatographic column radius, reactor radius and chromatographic particle diameter. The assumptions and conditions are that the van Deemter equation applies, the mass transfer limitation is for intraparticle diffusion in spherical particles, the velocity is at the optimum, the analyte’s retention factor, k′, is zero, the post-column reactor is only long enough to allow complete mixing of reagents and analytes and the maximum operating pressure of the pumping system is used. Optimal ranges of the reactor radius (ar) are obtained by comparing the number of observed theoretical plates (and theoretical plates per time) with and without a reactor. Results show that the acceptable reactor radii depend on column diameter, particle diameter, and maximum available pressure. Optimal ranges of ar become narrower as column diameter increases, particle diameter decreases or the maximum pressure is decreased. When the available pressure is 4000 psi, a Capillary Taylor Reactor with 12 μm radius is suitable for all columns smaller than 150 μm (radius) packed with 2–5 μm particles. For 1 μm packing particles, only columns smaller than 42.5 μm (radius) can be used and the reactor radius needs to be 5 μm. PMID:16494886
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asako, Y.; Nakamura, H.; Faghri, M.
1990-08-01
Natural convection is often a convenient and inexpensive mode of heat transfer. It is commonly employed in the cooling of electronic equipment and many other applications. Since the initial work by Bodoia and Osterle (1962) on finite difference solutions of natural convection between vertical isothermal plates, many other researchers have studied natural convection in vertical channels. Specifically Davis and Perona (1971) studied natural convection in vertical heated tubes. A thermally insulated chimney attached to a vertical heated channel induces an increase in the natural convection in the channel and leads to a higher heat transfer rate. This is the well-knownmore » chimney effect discussed in the paper by Haaland and Sparrow (1983). If the chimney diameter is larger than the heated tube diameter, the friction loss in the chimney region decreases with increasing chimney diameter. This induces an increase in the mass flow rate and leads to a higher heat transfer rate than the case for a chimney of the same diameter. However, from a geometric consideration it is evident that the chimney effect diminishes in the limiting case of an extremely large chimney diameter compared with its height. Therefore, there exists an optimum diameter where the heat transfer is maximum. To investigate the chimney effect computations are carried out for a Rayleigh number of 12.5, based on the heated tube radius, and for a Prandtl number of 0.7. The numerical results are based on a control volume finite difference method. The average Nusselt number results are compared with the numerical results obtained for a chimney attached to a tube of the same diameter.« less
Sargent, J; Connolly, D J; Watts, V; Mõtsküla, P; Volk, H A; Lamb, C R; Fuentes, V Luis
2015-11-01
Echocardiography is used routinely to assess mitral regurgitation severity, but echocardiographic measures of mitral regurgitation in dogs have not been compared with other quantitative methods. The study aim was to compare echocardiographic measures of mitral regurgitation with cardiac magnetic resonance imaging-derived mitral regurgitant fraction in small-breed dogs. Dogs with myxomatous mitral valve disease scheduled for magnetic resonance imaging assessment of neurological disease were recruited. Correlations were tested between cardiac magnetic resonance imaging-derived mitral regurgitant fraction and the following echocardiographic measures: vena contracta/aortic diameter, transmitral E-wave velocity, amplitude of mitral prolapse/aortic diameter, diastolic left ventricular diameter:aortic diameter, left atrium:aortic diameter, mitral regurgitation jet area ratio and regurgitant fraction calculated using the proximal isovelocity surface area method. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction was attempted in 21 dogs. Twelve consecutive, complete studies were obtained and 10 dogs were included in the final analysis: vena contracta/aortic diameter (r = 0 · 89, p = 0 · 001) and E-wave velocity (r = 0 · 86, p = 0 · 001) had the strongest correlations with cardiac magnetic resonance imaging-derived mitral regurgitant fraction. E velocity had superior repeatability and could be measured in all dogs. The presence of multiple jets precluded vena contracta/aortic diameter measurement in one dog. Measurement of cardiac magnetic resonance imaging-derived mitral regurgitant fraction is feasible but technically demanding. The echocardiographic measures that correlated most closely with cardiac magnetic resonance imaging-derived mitral regurgitant fraction were vena contracta/aortic diameter and E-wave velocity. © 2015 British Small Animal Veterinary Association.
The impact of luminance on tonic and phasic pupillary responses to sustained cognitive load.
Peysakhovich, Vsevolod; Vachon, François; Dehais, Frédéric
2017-02-01
Pupillary reactions independent of light conditions have been linked to cognition for a long time. However, the light conditions can impact the cognitive pupillary reaction. Previous studies underlined the impact of luminance on pupillary reaction, but it is still unclear how luminance modulates the sustained and transient components of pupillary reaction - tonic pupil diameter and phasic pupil response. In the present study, we investigated the impact of the luminance on these two components under sustained cognitive load. Fourteen participants performed a novel working memory task combining mathematical computations with a classic n-back task. We studied both tonic pupil diameter and phasic pupil response under low (1-back) and high (2-back) working memory load and two luminance levels (gray and white). We found that the impact of working memory load on the tonic pupil diameter was modulated by the level of luminance, the increase in tonic pupil diameter with the load being larger under lower luminance. In contrast, the smaller phasic pupil response found under high load remained unaffected by luminance. These results showed that luminance impacts the cognitive pupillary reaction - tonic pupil diameter (phasic pupil response) being modulated under sustained (respectively, transient) cognitive load. These findings also support the relationship between the locus-coeruleus system, presumably functioning in two firing modes - tonic and phasic - and the pupil diameter. We suggest that the tonic pupil diameter tracks the tonic activity of the locus-coeruleus while phasic pupil response reflects its phasic activity. Besides, the designed novel cognitive paradigm allows the simultaneous manipulation of sustained and transient components of the cognitive load and is useful for dissociating the effects on the tonic pupil diameter and phasic pupil response. Copyright © 2016 Elsevier B.V. All rights reserved.
Majos, Marcin; Stefańczyk, Ludomir; Szemraj-Rogucka, Zofia; Elgalal, Marcin; De Caro, Raffaele; Macchi, Veronica; Polguj, Michał
2018-04-01
An in-depth knowledge of renal vascular anatomy is essential when planning many surgical procedures; however, a few data exists regarding renal artery diameter. The aim of this study was to assess this morphological feature and to investigate whether a correlation exists between renal artery diameter and the type of arterial supply, with a particular emphasis on variant anatomy and the presence of multiple renal arteries. Computed tomography angiography (CTA) studies of 248 patients, i.e., a total of 496 kidneys, were evaluated. The mean age of the patients was 66.4 ± 15.01 years. Renal artery diameter was measured based on the type of arterial blood supply. The frequency of occurrence of three anatomic variants of renal arterial supply was established: single renal artery (RA) 43.35%, single artery with prehilar branching (pRA) 37.30%, and multiple renal artery (mRA) 19.35%. The diameter of single renal arteries, with either prehilar or hilar branching, was significantly larger than when multiple arteries were present. A detailed analysis of just the mRA variant demonstrated that the diameter of the renal arteries in men was larger (p = 0.012) than those in women and that there was no difference in diameter with regard to the side of the body (p = 0.219). The classification described in our study containing a detailed description of renal artery diameter. It may be helpful in clinical practice, especially for transplantologists, surgeons, and vascular surgeons.
The Importance of Large-Diameter Trees to Forest Structural Heterogeneity
Lutz, James A.; Larson, Andrew J.; Freund, James A.; Swanson, Mark E.; Bible, Kenneth J.
2013-01-01
Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. However, their attendant contributions to forest heterogeneity are rarely addressed. We established the Wind River Forest Dynamics Plot, a 25.6 ha permanent plot within which we tagged and mapped all 30,973 woody stems ≥1 cm dbh, all 1,966 snags ≥10 cm dbh, and all shrub patches ≥2 m2. Basal area of the 26 woody species was 62.18 m2/ha, of which 61.60 m2/ha was trees and 0.58 m2/ha was tall shrubs. Large-diameter trees (≥100 cm dbh) comprised 1.5% of stems, 31.8% of basal area, and 17.6% of the heterogeneity of basal area, with basal area dominated by Tsuga heterophylla and Pseudotsuga menziesii. Small-diameter subpopulations of Pseudotsuga menziesii, Tsuga heterophylla and Thuja plicata, as well as all tree species combined, exhibited significant aggregation relative to the null model of complete spatial randomness (CSR) up to 9 m (P≤0.001). Patterns of large-diameter trees were either not different from CSR (Tsuga heterophylla), or exhibited slight aggregation (Pseudotsuga menziesii and Thuja plicata). Significant spatial repulsion between large-diameter and small-diameter Tsuga heterophylla suggests that large-diameter Tsuga heterophylla function as organizers of tree demography over decadal timescales through competitive interactions. Comparison among two forest dynamics plots suggests that forest structural diversity responds to intermediate-scale environmental heterogeneity and disturbances, similar to hypotheses about patterns of species richness, and richness- ecosystem function. Large mapped plots with detailed within-plot environmental spatial covariates will be required to test these hypotheses. PMID:24376579
The importance of large-diameter trees to forest structural heterogeneity.
Lutz, James A; Larson, Andrew J; Freund, James A; Swanson, Mark E; Bible, Kenneth J
2013-01-01
Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. However, their attendant contributions to forest heterogeneity are rarely addressed. We established the Wind River Forest Dynamics Plot, a 25.6 ha permanent plot within which we tagged and mapped all 30,973 woody stems ≥ 1 cm dbh, all 1,966 snags ≥ 10 cm dbh, and all shrub patches ≥ 2 m(2). Basal area of the 26 woody species was 62.18 m(2)/ha, of which 61.60 m(2)/ha was trees and 0.58 m(2)/ha was tall shrubs. Large-diameter trees (≥ 100 cm dbh) comprised 1.5% of stems, 31.8% of basal area, and 17.6% of the heterogeneity of basal area, with basal area dominated by Tsuga heterophylla and Pseudotsuga menziesii. Small-diameter subpopulations of Pseudotsuga menziesii, Tsuga heterophylla and Thuja plicata, as well as all tree species combined, exhibited significant aggregation relative to the null model of complete spatial randomness (CSR) up to 9 m (P ≤ 0.001). Patterns of large-diameter trees were either not different from CSR (Tsuga heterophylla), or exhibited slight aggregation (Pseudotsuga menziesii and Thuja plicata). Significant spatial repulsion between large-diameter and small-diameter Tsuga heterophylla suggests that large-diameter Tsuga heterophylla function as organizers of tree demography over decadal timescales through competitive interactions. Comparison among two forest dynamics plots suggests that forest structural diversity responds to intermediate-scale environmental heterogeneity and disturbances, similar to hypotheses about patterns of species richness, and richness- ecosystem function. Large mapped plots with detailed within-plot environmental spatial covariates will be required to test these hypotheses.
Geometric Limitations Of Ultrasonic Measurements
NASA Astrophysics Data System (ADS)
von Nicolai, C.; Schilling, F.
2006-12-01
Laboratory experiments are a key for interpreting seismic field observations. Due to their potential in many experimental set-ups, the determination of elastic properties of minerals and rocks by ultrasonic measurements is common in Geosciences. The quality and thus use of ultrasonic data, however, strongly depends on the sample geometry and wavelength of the sound wave. Two factors, the diameter-to-wavelength- ratio and the diameter-to-length-ratio, are believed to be the essential parameters to affect ultrasonic signal quality. In this study, we determined under well defined conditions the restricting dimensional parameters to test the validity of published assumptions. By the use of commercial ultrasonic transducers a number of experiments were conducted on aluminium, alumina, and acrylic glass rods of varying diameter (30-10 mm) and constant length. At each diameter compressional wave travel times were measured by pulse- transmission method. From the observed travel times ultrasonic wave velocities were calculated. One additional experiment was performed with a series of square-shaped aluminium blocks in order to investigate the effect of the geometry of the samples cross-sectional area. The experimental results show that the simple diameter-to-wavelength ratios are not valid even under idealized experimental conditions and more complex relation has to be talen into account. As diameter decreases the P-waves direct phase is increasingly interfered and weakened by sidewall reflections. At very small diameters compressional waves are replaced by bar waves and P-wave signals become non resolvable. Considering the suppression of both effects, a critical D/ë-ratio was determined and compared to experimental set-ups from various publications. These tests indicate that some published and cited data derived from small diameter set-ups are out off the range of physical possibility.
Kim, Ki Han; Kim, Min Chan; Jung, Ghap Joong
2012-11-01
Gastric surgery may potentiate delayed gastric emptying. Billroth I gastroduodenostomy using a circular stapler is the most preferable reconstruction method. The purpose of this study is to analyze the risk factors associated with delayed gastric emptying after radical subtotal gastrectomy with Billroth I anastomosis using a stapler for early gastric cancer. Three hundred and seventy-eight patients who underwent circular stapled Billroth I gastroduodenostomy after subtotal gastrectomy due to early gastric cancer were analyzed retrospectively. One hundred and eighty-two patients had Billroth I anastomosis using a 25 mm diameter circular stapler, and 196 patients had anastomosis with a 28 or 29 mm diameter circular stapler. Clinicopathological features and postoperative outcomes were evaluated and compared between the two groups. Delayed gastric emptying was diagnosed by symptoms and simple abdomen X-ray with or without upper gastrointestinal series or endoscopy. Postoperative delayed gastric emptying was found in 12 (3.2%) of the 378 patients. Among all the variables, distal margin and circular stapler diameter were significantly different between the cases with delayed gastric emptying and no delayed gastric emptying. There were statistically significant differences in sex, body mass index, comorbidity, complication, and operation type according to circular stapler diameter. In both univariate and multivariate logistic regression analyses, only the stapler diameter was found to be a significant factor affecting delayed gastric emptying (P = 0.040). In this study, the circular stapler diameter was one of the most significant predictable factors of delayed gastric emptying for Billroth I gastroduodenostomy. The use of a 28 or 29 mm diameter circular stapler rather than a 25 mm diameter stapler in stapled gastroduodenostomy for early gastric cancer can reduce postoperative delayed gastric emptying associated with anastomosic stenosis or edema with relative safety.
Fatkullin, Nail; Fischer, Elmar; Mattea, Carlos; Beginn, Uwe; Kimmich, Rainer
2004-06-21
A spinodal demixing technique was employed for the preparation of linear poly(ethylene oxide) (PEO) confined in nanoscopic strands, which in turn are embedded in a quasi-solid methacrylate matrix impenetrable to PEO. Both the molecular weight of the PEO and the mean diameter of the strands are variable to a certain degree. Chain dynamics of the PEO in the molten state were examined with the aid of field-gradient NMR diffusometry and field-cycling NMR relaxometry. The dominating mechanism for translational displacements in the nanoscopic strands is shown to be reptation. A formalism for the evaluation of NMR diffusometry is presented, which permits the estimation of the mean PEO strand diameter. Samples of different composition revealed diameters in the range 9-58 nm, in reasonable agreement with electron micrographs. The time scale of the diffusion measurements was 10-300 ms. On the much shorter time scale of field-cycling NMR relaxometry, 10(-9)-10(-4)s, a frequency dispersion of the spin-lattice relaxation time characteristic for reptation clearly showed up in all samples. An effective tube diameter of only 0.6 nm was found even when the strand diameter was larger than the radius of gyration of the PEO chain random coils. The finding that the tube diameter effective on the short time scale of field-cycling NMR relaxometry is much smaller than the diameter of the confining structure is termed the "corset effect", and is traced back to the lack of local free-volume fluctuation capacity under nanoscale confinements. The order of magnitude of the 'pore' diameter, at which the cross-over from confined to bulk chain dynamics is expected, is estimated.
Imakuma, E S; Bordini, A L; Millan, L S; Massarollo, P C B; Caldini, E T E G
2014-01-01
In living donor liver transplantation, the right-sided graft presents thin and short vessels, bringing forward a more difficult anastomosis. In these cases, an interpositional arterial autograft can be used to favor the performance of the arterial anastomosis, making the procedure easier and avoiding surgical complications. We compared the inferior mesenteric artery (IMA), the splenic artery (SA), the inferior epigastric artery (IEA), the descending branch of the lateral circumflex femoral artery (LCFA), and the proper hepatic artery (PHA) as options for interpositional autograft in living donor liver transplantation. Segments of at least 3 cm of all 5 arteries were harvested from 16 fresh adult cadavers from both genders through standardized dissection. The analyzed measures were proximal and distal diameter and length. The proximal diameter of the RHA and the distal diameter of the SA, IMA, IEA and the LCFA were compared to the distal diameter of the RHA. The proximal and distal diameters of the SA, IEA and LCFA were compared to study caliber gain of each artery. All arteries except the IMA showed statistical significant difference in relation to the RHA in terms of diameter. Regarding caliber gain, the arteries demonstrated statistical significant difference. All the harvested arteries except PHA were 3 cm in length. The IMA demonstrated the best compatibility with the RHA in terms of diameter and showed sufficient length to be employed as interpositional graft. The PHA, the SA, the IEA and the LCFA presented statistically significant different diameters when compared to the RHA. Among these vessels, only the PHA did not show sufficient mean length. Copyright © 2014 Elsevier Inc. All rights reserved.
Nguyen, Yann; Bernardeschi, Daniele; Kazmitcheff, Guillaume; Miroir, Mathieu; Vauchel, Thomas; Ferrary, Evelyne; Sterkers, Olivier
2015-02-01
Loading otoprotective drug into cochlear implant might change its mechanical properties, thus compromising atraumatic insertion. This study evaluated the effect of incorporation of dexamethasone (DXM) in the silicone of cochlear implant arrays on insertion forces. Local administration of DXM with embedded array can potentially reduce inflammation and fibrosis after cochlear implantation procedure to improve hearing preservation and reduce long-term impedances. Four models of arrays have been tested: 0.5-mm distal diameter array (n = 5) used as a control, drug-free 0.4-mm distal diameter array (n = 5), 0.4-mm distal diameter array with 1% eluded DXM silicone (n = 5), and 0.4-mm distal diameter array with 10% eluded DXM silicone (n = 5). Via a motorized insertion bench, each array has been inserted into an artificial scala tympani model. The forces were recorded by a 6-axis force sensor. Each array was tested seven times for a total number of 140 insertions. During the first 10-mm insertion, no difference between the four models was observed. From 10- to 24-mm insertion, the 0.5-mm distal diameter array presented higher insertion forces than the drug-free 0.4-mm distal diameter arrays, with or without DXM. Friction forces for drug-free 0.4-mm distal diameter array and 0.4-mm distal diameter DXM eluded arrays were similar on all insertion lengths. Incorporation of DXM in silicone for cochlear implant design does not change electrode array insertion forces. It does not raise the risk of trauma during array insertion, making it suitable for long-term in situ administration to the cochlea.
Tennert, Christian; Herbert, Josef; Altenburger, Markus Jörg; Wrbas, Karl-Thomas
2010-10-01
An exact determination of the apical root canal diameter is crucial for correct cleaning and shaping of a root canal. The aim of this study was to investigate the discrepancies of the initial apical root canal diameter and the diameter that is measured by the initial apical file (IAF) after cervical flaring using current rotary nickel-titanium systems. Mesiobuccal canals of 40 extracted mandibular molars were randomly assigned to four groups. In the first group, root canals were not flared. Root canals of the other groups were preflared using FlexMaster (VDW, Munich, Germany), ProTaper (Dentsply, Konstanz, Germany), or RaCe (FKG Dentaire, Genf, Switzerland) instruments. The tooth length was determined by inserting an ISO 06 K-file to the apical foramen. The working length (WL) was set 1 mm short of the apical foramen. File sizes were increased after binding sensation was felt at the WL. Transversal sections of the WL regions were examined under stereomicroscope, and the diameter of the root canal and the IAF at WL were assessed. Canals preflared with RaCe instruments had the lowest discrepancy between the apical root canal diameter and the IAF diameter (15.7 ± 9.7 μm) followed by ProTaper (22.2 ± 11.0 μm) and FlexMaster (35.0 ± 17.2 μm). Preflaring of root canals prevents underestimation of the actual apical root canal diameter. The type of instruments used for preflaring show differences on the accuracy of IAF determination. Preflaring with larger tapered instruments leads to a more accurate apical sizing, and this information is crucial concerning the appropriate final diameter for complete apical shaping. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Imani, Gérard; Boyemba, Faustin; Lewis, Simon; Nabahungu, Nsharwasi Léon; Calders, Kim; Zapfack, Louis; Riera, Bernard; Balegamire, Clarisse; Cuni-Sanchez, Aida
2017-01-01
Tropical montane forests provide an important natural laboratory to test ecological theory. While it is well-known that some aspects of forest structure change with altitude, little is known on the effects of altitude on above ground biomass (AGB), particularly with regard to changing height-diameter allometry. To address this we investigate (1) the effects of altitude on height-diameter allometry, (2) how different height-diameter allometric models affect above ground biomass estimates; and (3) how other forest structural, taxonomic and environmental attributes affect above ground biomass using 30 permanent sample plots (1-ha; all trees ≥ 10 cm diameter measured) established between 1250 and 2600 m asl in Kahuzi Biega National Park in eastern Democratic Republic of Congo. Forest structure and species composition differed with increasing altitude, with four forest types identified. Different height-diameter allometric models performed better with the different forest types, as trees got smaller with increasing altitude. Above ground biomass ranged from 168 to 290 Mg ha-1, but there were no significant differences in AGB between forests types, as tree size decreased but stem density increased with increasing altitude. Forest structure had greater effects on above ground biomass than forest diversity. Soil attributes (K and acidity, pH) also significantly affected above ground biomass. Results show how forest structural, taxonomic and environmental attributes affect above ground biomass in African tropical montane forests. They particularly highlight that the use of regional height-diameter models introduces significant biases in above ground biomass estimates, and that different height-diameter models might be preferred for different forest types, and these should be considered in future studies.
Morphometry of impact craters on Mercury from MESSENGER altimetry and imaging
NASA Astrophysics Data System (ADS)
Susorney, Hannah C. M.; Barnouin, Olivier S.; Ernst, Carolyn M.; Johnson, Catherine L.
2016-06-01
Data acquired by the Mercury Laser Altimeter and the Mercury Dual Imaging System on the MESSENGER spacecraft in orbit about Mercury provide a means to measure the geometry of many of the impact craters in Mercury's northern hemisphere in detail for the first time. The combination of topographic and imaging data permit a systematic evaluation of impact crater morphometry on Mercury, a new calculation of the diameter Dt at which craters transition with increasing diameter from simple to complex forms, and an exploration of the role of target properties and impact velocity on final crater size and shape. Measurements of impact crater depth on Mercury confirm results from previous studies, with the exception that the depths of large complex craters are typically shallower at a given diameter than reported from Mariner 10 data. Secondary craters on Mercury are generally shallower than primary craters of the same diameter. No significant differences are observed between the depths of craters within heavily cratered terrain and those of craters within smooth plains. The morphological attributes of craters that reflect the transition from simple to complex craters do not appear at the same diameter; instead flat floors first appear with increasing diameter in craters at the smallest diameters, followed with increasing diameter by reduced crater depth and rim height, and then collapse and terracing of crater walls. Differences reported by others in Dt between Mercury and Mars (despite the similar surface gravitational acceleration on the two bodies) are confirmed in this study. The variations in Dt between Mercury and Mars cannot be adequately attributed to differences in either surface properties or mean projectile velocity.
2014-01-01
Objectives To evaluate the interobserver reliability of echocardiographic findings of right ventricle (RV) dysfunction for prognosticating normotensive patients with pulmonary embolism (PE). Methods A central panel of cardiologists evaluated echocardiographic studies of 75 patients included in the PROTECT study for the following signs: RV diameter, RV/left ventricular (LV) diameter ratio, hypokinesis of the RV free wall, and tricuspid plane systolic excursion (TAPSE). Investigators used intraclass correlation to assess agreement between the measurements of the central panel and each of the local cardiologists. Investigators used the single weighted kappa statistic to test for agreement between readers of interpretation of RV enlargement and RV hypokinesis. Results The two observers had fair agreement (k = 0.45) for RV enlargement assessed by the RV diameter, and good agreement (k = 0.65) for RV enlargement assessed by the RV/LV diameter ratio. The interobserver reliability of the assessment whether hypokinesis of the RV free wall is present was good (к = 0.70), and whether RV dysfunction (assessed by TAPSE measurement) is present was very good (k = 0.86). The intraclass correlation for the RV/LV diameter ratio was fair (0.55; 95% confidence interval [CI], 0.37-0.69), for the RV diameter was good (0.70; 95% CI, 0.56-0.80), and for the TAPSE measurement was very good (0.85; 95% CI, 0.77-0.90). On Bland-Altman analysis, the mean differences for RV diameter, RV/LV diameter ratio and TAPSE measurement were 2.33 (±5.38), 0.06 (±0.23) and 0.08 (±2.20), respectively. Conclusion TAPSE measurement is the least user dependent and most reproducible echocardiographic finding of RV dysfunction in normotensive patients with PE. PMID:25092465
Mancini, Valentina; Ribolsi, Mentore; Gentile, Massimo; de'Angelis, Gianluigi; Bizzarri, Barbara; Lindley, Keith J; Cucchiara, Salvatore; Cicala, Michele; Borrelli, Osvaldo
2012-12-01
We sought to compare intercellular space diameter in children with non-erosive and erosive reflux disease, and a control group. We also aimed to characterize the reflux pattern in erosive and non-erosive reflux disease patients, and to explore the relationship between intercellular space diameter values and reflux parameters. Twenty-four children with non-erosive reflux disease, 20 with erosive reflux disease, and 10 controls were prospectively studied. All patients and controls underwent upper endoscopy. Biopsies were taken at 2-3 cm above the Z-line, and intercellular space diameter was measured using transmission electron microscopy. Non-erosive and erosive reflux disease patients underwent impedance-pH monitoring. Mean intercellular space diameter values were significantly higher in both non-erosive (0.9 ± 0.2 μm) and erosive reflux disease (1 ± 0.2 μm) compared to controls (0.5 ± 0.2 μm, p<0.01). No difference was found between the two patient groups. Acid exposure time, the number of acid, weakly acidic and weakly alkaline reflux events did not differ between the two patient groups. No difference was found in the mean intercellular space diameter between non-erosive reflux disease children with and without abnormal acid exposure time (1 ± 0.3 vs. 0.9 ± 0.2 μm). No correlation was found between any reflux parameter and intercellular space diameter values. Dilated intercellular space diameter seems to be a useful and objective marker of oesophageal damage in paediatric gastro-oesophageal reflux disease, regardless of acid exposure. In childhood, different gastro-oesophageal reflux disease phenotypes cannot be discriminated on the basis of reflux pattern. Copyright © 2012 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
Reinstein, Dan Z; Lovisolo, Carlo F; Archer, Timothy J; Gobbe, Marine
2013-01-01
To compare vault height predictability of Implantable Collamer Lens (ICL; Staar Surgical) sizing using a sulcus diameter-based formula or the manufacturer-recommended white-to-white-based method. In 50 myopic eyes, ICL size was calculated using both a formula including sulcus diameter and the traditional formula based on white-to-white diameter. Sulcus diameter was measured using Artemis 2 very high-frequency (VHF) digital ultrasound (ArcScan Inc). Implantation was based on the sulcus diameter derived size. Actual postoperative vault height achieved was measured by VHF digital ultrasound scanning. Circle segment trigonometry was used to calculate the vault height that would have resulted had lens sizing been based on the white-to-white formula. The same lens size would have been used in 60% of eyes, a smaller lens would have been used in 34% of eyes and a larger lens in 6% of eyes had lens sizing been based on the white-to-white formula. Mean vault for eyes with lenses sized using the sulcus diameter formula was 0.37±0.16 mm (range: 0.08 to 0.92 mm), with 2% <0.09 mm, the recognized low-vault height for risk of cataract. Circle segment trigonometry predicted that the vault height would have been 0.24±0.28 mm (range: -0.31 to 0.92 mm), with 26% <0.09 mm had lens sizing been based on the white-to-white formula. Significantly better predictability of postoperative vault height was achieved by including sulcus diameter into the ICL sizing formula compared with using the traditional white-to-white-based formula. Copyright 2013, SLACK Incorporated.
Craters formed in mineral dust by hypervelocity microparticles.
NASA Technical Reports Server (NTRS)
Vedder, J. F.
1972-01-01
As a simulation of erosion processes on the lunar surface, impact craters were formed in dust targets by 2- to 5-micron-diameter polystyrene spheres with velocities between 2.5 and 12 km/sec. For weakly cohesive, thick targets of basalt dust with a maximum grain size comparable to the projectile diameter, the craters had an average projectile-to-diameter diameter ratio of 25, and the displaced mass was 3 orders of magnitude greater than the projectile mass. In a simulation of the effect of a dust covering on lunar rocks, a layer of cohesive, fine-grained basalt dust with a thickness nearly twice the projectile diameter protected a glass substrate from damage, but an area about 50 times the cross-sectional area of the projectile was cleared of all but a few grains. Impact damage was produced in glass under a thinner dust layer.
Passive Control of Vortex Shedding via Screen Shroud
NASA Astrophysics Data System (ADS)
Azmi, A. M.; Zhou, T.
2017-12-01
The turbulent wake of screen-shrouded cylinders were experimentally investigated using flow visualization. Screen cylinders made from screen mesh of various porosity (37%, 49%, 61% and 67%) were used as the shrouds. The main purpose of the study is to examine the effect of screen porosity, β and screen diameter ratio, dw /D (wire diameter to cylinder diameter ratio) on the vortex development behind the shrouded cylinders, particularly in supressing the vortex shedding from a circular cylinder. The diameter ratio between the screen shroud and the plain cylinder, D/d was 2.0. The flow Reynolds number based on the shroud diameter, ReD was about 1000. Results showed that the inclusion of the screen shrouds has significant impact on the wake of the circular cylinder. With larger value of the non-dimensional parameter βdw /D, vortex was impaired and the formation length was longer in the shrouded cylinder wake. The vortex generation mechanism was also discussed.
Development of welded metal bellows having minimum effective diameter change
NASA Technical Reports Server (NTRS)
Henschel, J. K.; Stevens, J. B.; Harvey, A. C.; Howland, J. S.; Rhee, S. S.
1972-01-01
A program of analysis, design, and fabrication was conducted to develop welded metal bellows having a minimum change in effective diameter for cryogenic turbomachinery face seal applications. Linear analysis of the principle types of bellows provided identification of concepts capable of meeting basic operation requirements. For the 6-inch (.152 m) mean diameter, 1.5-inch free length bellows studied, nonlinear analysis showed that opposed and nested toroidal bellows plates stiffened by means of alternating stiffener rings were capable of maintaining constant effective diameter within 0.3% and 0.1% respectively under the operating conditions of interest. Changes in effective diameter were due principally to bellows axial deflection with pressure differential having a lesser influence. Fabrication problems associated with joining the thin bellows plates to the relatively heavy stiffener rings were encountered and precluded assembly and testing of a bellows core. Fabrication problems are summarized and recommended fabrication methods for future effort are presented.
Measurement and modeling of diameter distributions of particulate matter in terrestrial solutions
NASA Astrophysics Data System (ADS)
Levia, Delphis F.; Michalzik, Beate; Bischoff, Sebastian; NäThe, Kerstin; Legates, David R.; Gruselle, Marie-Cecile; Richter, Susanne
2013-04-01
Particulate matter (PM) plays an important role in biogeosciences, affecting biosphere-atmosphere interactions and ecosystem health. This is the first known study to quantify and model PM diameter distributions of bulk precipitation, throughfall, stemflow, and organic layer (Oa) solution. Solutions were collected from a European beech (Fagus sylvatica L.) forest during leafed and leafless periods. Following scanning electron microscopy and image analysis, PM distributions were quantified and then modeled with the Box-Cox transformation. Based on an analysis of 43,278 individual particulates, median PM diameter of all solutions was around 3.0 µm. All PM diameter frequency distributions were skewed significantly to the right. Optimal power transformations of PM diameter distributions were between -1.00 and -1.56. The utility of this model reconstruction would be that large samples having a similar probability density function can be developed for similar forests. Further work on the shape and chemical composition of particulates is warranted.
NASA Technical Reports Server (NTRS)
Malin, M. C.; Dzurisin, D.
1977-01-01
Craters on Mercury, the moon, and Mars were classified into two groups, namely, fresh and degraded craters, on the basis of qualitative visual degradation as revealed by degree of rim crispness, terraced interior walls, slumping from crater walls, etc., and the depth/diameter relationship of craters was studied. Lunar and Mercurian crater populations indicate the existence of terrain-correlated degradational phenomena. The depth/diameter relations for Mercury and the moon display remarkably similar forms, suggesting similar degrees of landform degradation. Depth/diameter curves display a break in slope, dividing two distinct crater populations. Mars craters show few of the trends of those of Mercury and the moon. The depth/diameter curve has no definite break in slope, though there is considerable depth variation. The role of nonballistic degradation in connection with the early formation of large expanses of intercrater plains is discussed.
Seo, Yeong-Hyeon; Hwang, Kyungmin; Jeong, Ki-Hun
2018-02-19
We report a 1.65 mm diameter forward-viewing confocal endomicroscopic catheter using a flip-chip bonded electrothermal MEMS fiber scanner. Lissajous scanning was implemented by the electrothermal MEMS fiber scanner. The Lissajous scanned MEMS fiber scanner was precisely fabricated to facilitate flip-chip connection, and bonded with a printed circuit board. The scanner was successfully combined with a fiber-based confocal imaging system. A two-dimensional reflectance image of the metal pattern 'OPTICS' was successfully obtained with the scanner. The flip-chip bonded scanner minimizes electrical packaging dimensions. The inner diameter of the flip-chip bonded MEMS fiber scanner is 1.3 mm. The flip-chip bonded MEMS fiber scanner is fully packaged with a 1.65 mm diameter housing tube, 1 mm diameter GRIN lens, and a single mode optical fiber. The packaged confocal endomicroscopic catheter can provide a new breakthrough for diverse in-vivo endomicroscopic applications.
Effect of Shock Precompression on the Critical Diameter of Liquid Explosives
NASA Astrophysics Data System (ADS)
Petel, Oren E.; Higgins, Andrew J.; Yoshinaka, Akio C.; Zhang, Fan
2006-07-01
The critical diameter of both ambient and shock-precompressed liquid nitromethane confined in PVC tubing are measured experimentally. The experiment was conducted for both amine sensitized and neat NM. In the precompression experiments, the explosive is compressed by a strong shock wave generated by a donor explosive and reflected from a high impedance anvil prior to being detonated by a secondary event. The pressures reached in the test sections prior to detonation propagation was approximately 7 and 8 GPa for amine sensitized and neat NM respectively. The results demonstrated a 30% - 65% decrease in the critical diameter for the shock-compressed explosives. This critical diameter decrease is observed despite a significant decrease in the predicted Von Neumann temperature of the detonation in the precompressed explosive. The results are discussed in the context of theoretical predictions based on thermal ignition theory and previous critical diameter measurements.
Hwang, Da Young; Suh, Dong Hack
2014-06-07
Unlike nanoscrolls of 2D graphene, those of 2D h-BN have not been demonstrated, except for only a few experimental reports. Nanoscrolls of h-BN with high yields and reproducibility are first synthesized by a simple solution process. Inner-tube diameters of BNSs including LCAs, N-(2-aminoethyl)-3α-hydroxy-5β-cholan-24-amide, a bile acid derivative and self-assembling material, can be controlled by adjusting the diameter of the LCA fiber which is grown by self-assembly. TEM and SEM images show that BNSs have a tube-like morphology and the inner-tube diameter of BNSs can be controlled in the range from 20 to 60 nm for a smaller diameter, up to 300 nm for a larger diameter by LCA fiber growth inside the BNSs. Finally, open cylindrical BNSs with hollow cores were obtained by dissolving LCAs inside BNSs.
Plasma Discharge with Different Electrode Diameters for Reducing Methylene Blue Concentration
NASA Astrophysics Data System (ADS)
Rasyidah, H.; Kusumandari; Saraswati, T. E.; Anwar, M.
2018-03-01
Recently, plasma technology has gained attention since it overcomes the shortcomings of water treatment. This research studies the effect of electrode diameter of plasma discharge reactors on the concentration reduction of methylene blue as an organic solution. The plasma discharge reactor was built from a pair of stainless needle electrodes connected with high-AC voltage. The electrodes were placed approximately 2 mm above the solution and stirred at 5.5 rpm. The diameters of the electrodes were 2, 3.2 and 4 mm. The times for plasma treatment were set at 2, 4, 6, 8 and 10 min. Absorbance, temperature and pH of the solution were measured to know the effects of electrode diameter of the plasma reactor. Absorbance and pH significantly decreased after plasma treatment. The best of the absorbance reduction were obtained when the sample was treated under plasma discharge using the smallest diameter electrodes for 8-10 min.
High peak-power kilohertz laser system employing single-stage multi-pass amplification
Shan, Bing; Wang, Chun; Chang, Zenghu
2006-05-23
The present invention describes a technique for achieving high peak power output in a laser employing single-stage, multi-pass amplification. High gain is achieved by employing a very small "seed" beam diameter in gain medium, and maintaining the small beam diameter for multiple high-gain pre-amplification passes through a pumped gain medium, then leading the beam out of the amplifier cavity, changing the beam diameter and sending it back to the amplifier cavity for additional, high-power amplification passes through the gain medium. In these power amplification passes, the beam diameter in gain medium is increased and carefully matched to the pump laser's beam diameter for high efficiency extraction of energy from the pumped gain medium. A method of "grooming" the beam by means of a far-field spatial filter in the process of changing the beam size within the single-stage amplifier is also described.
NASA Astrophysics Data System (ADS)
Azad, Saeed; Sadeghi, Ebrahim; Parvizi, Roghaieh; Mazaheri, Azardokht; Yousefi, M.
2017-05-01
In this work, the multimode optical fiber size effects on the performances of the clad-modified fiber with ZnO nanorods relative humidity (RH) sensor were experimentally investigated. Simple and controlled chemical etching method through on line monitoring was used to prepare different fiber waist diameter with long length of 15 mm. More precisely, the competition behavior of sensor performances with varying fiber waist diameter was studied to find appropriate size of maximizing evanescent fields. The obtained results revealed that evanescent wave absorption coefficient (γ) enhanced more than 10 times compare to bare fiber at the proposed optimum fiber diameter of 28 μm. Also, high linearity and fast recovery time about 7 s was obtained at the proposed fiber waist diameter. Applicable features of the proposed sensor allow this device to be used for humidity sensing applications, especially to be applied in remote sensing technologies.
Decreasing diameter fluctuation of polymer optical fiber with optimized drawing conditions
NASA Astrophysics Data System (ADS)
Çetinkaya, Onur; Wojcik, Grzegorz; Mergo, Pawel
2018-05-01
The diameter fluctuations of poly(methyl methacrylate) based polymer optical fibers, during drawing processes, have been comprehensively studied. In this study, several drawing parameters were selected for investigation; such as drawing tensions, preform diameters, preform feeding speeds, and argon flows. Varied drawing tensions were used to draw fibers, while other parameters were maintained at constant. At a later stage in the process, micro-structured polymer optical fibers were drawn under optimized drawing conditions. Fiber diameter deviations were reduced to 2.2%, when a 0.2 N drawing tension was employed during the drawing process. Higher drawing tensions led to higher diameter fluctuations. The Young’s modulus of fibers drawn with different tensions was also measured. Our results showed that fiber elasticity increased as drawing tensions decreased. The inhomogeneity of fibers was also determined by comparing the deviation of Young’s modulus.
Performance of large area xenon ion thrusters for orbit transfer missions
NASA Technical Reports Server (NTRS)
Rawlin, Vincent K.
1989-01-01
Studies have indicated that xenon ion propulsion systems can enable the use of smaller Earth-launch vehicles for satellite placement which results in significant cost savings. These analyses have assumed the availability of advanced, high power ion thrusters operating at about 10 kW or higher. A program was initiated to explore the viability of operating 50 cm diameter ion thrusters at this power level. Operation with several discharge chamber and ion extraction grid set combinations has been demonstrated and data were obtained at power levels to 16 kW. Fifty cm diameter thrusters using state of the art 30 cm diameter grids or advanced technology 50 cm diameter grids allow discharge power and beam current densities commensurate with long life at power levels up to 10 kW. In addition, 50 cm diameter thrusters are shown to have the potential for growth in thrust and power levels beyond 10 KW.
A computational algorithm addressing how vessel length might depend on vessel diameter
Jing Cai; Shuoxin Zhang; Melvin T. Tyree
2010-01-01
The objective of this method paper was to examine a computational algorithm that may reveal how vessel length might depend on vessel diameter within any given stem or species. The computational method requires the assumption that vessels remain approximately constant in diameter over their entire length. When this method is applied to three species or hybrids in the...
R. James Barbour; Dean L. Parry; John Punches; John Forsman; Robert Ross
2003-01-01
Small-diameter (5- to 10-inch diameter at breast height) Douglas-fi r (Pseudotsuga menziesii (Mirb.) Franco) and ponderosa pine (Pinus ponderosa Dougl. ex Laws) trees were assessed for product potential by diagramming the location, size, and type of knots visible on the wood surface (inside bark) and using the AUTOSAW sawing simulator to evaluate...
Economic feasibility of products from inland West small-diameter timber
Spelter Henry; Rong Wang; Peter Ince
1996-01-01
A large part of the forests located in the Rocky Mountain region of the U.S. West (inland West) is characterized by densely packed, small-diameter stands. The purpose of this study was to examine the economic feasibility of using small-diameter material from this resource to manufacture various wood products: oriented strandboard (OSB), stud lumber, random-length...
Veronica C. Lessard
2001-01-01
The Forest Inventory and Analysis (FIA) program of the North Central Research Station (NCRS), USDA Forest Service, has developed nonlinear, individual-tree, distance-independent annual diameter growth models. The models are calibrated for species groups and formulated as the product of an average diameter growth component and a modifier component. The regional models...
Thomas J. Dean; D. Andrew Scott; Ray A. Newbold
2010-01-01
Three models are compared for their ability to account for differences in diameter growth associated with different stages of stand development. Data for the comparisons were collected in young loblolly pine plantations treated variously at time of planting for the first 10 years since establishment. Neither the growth-growing stock model nor the accelerated...
Charles W. McMillin
1969-01-01
In Pinus taeda L., burst, breaking length, and sheet density were improved by using fiber refined from wood having long, narrow-diameter tracheids with thick walls. Only narrow-diameter teacheids with thick walls were required to improve tear factor. A theoretical stress analysis revealed that thick-walled cells of small outside diameter fail by...
Novel gradient-diameter magnetic nanowire arrays with unconventional magnetic anisotropy behaviors.
Wang, Jing; Zuo, Zhili; Huang, Liang; Warsi, Muhammad Asif; Xiao, John Q; Hu, Jun
2018-06-21
Fe-Co-Ni gradient-diameter magnetic nanowire arrays were fabricated via direct-current electrodeposition into a tapered anodic aluminium oxide template. In contrast to the magnetic behaviors of uniform-diameter nanowire arrays, these arrays exhibited tailorable magnetic anisotropy that can be used to switch magnetic nanowires easily and unconventional temperature-dependent coercivity with much better thermal stability.
Raise cutting diameters for increased returns
H. Clay Smith; G. R., Jr. Trimble; Paul S. DeBald
1979-01-01
Diameter-limit cutting is widely used to harvest logs in eastern hardwoods. Studies show that cutting limits are often set so low that they sacrifice financial returns. The value of lumber cut from logs is largely dependent on the diameter, grade, and tree species. As tree size increases so does the proportion of higher grade lumber, and this is reflected in improved...
Diameter growth, survival, and volume estimates for trees in Indiana and Illinois.
W. Brad Smith; Stephen R. Shifley
1984-01-01
Measurements of more that 15,000 Indiana and Illinois trees were summarized by species and diameter class into tables of mean annual diameter growth, annual probability of survival, net cubic foot volume, and net board foot volume. In the absence of better forecasting techniques, this information can be utilized to project short-term changes for Indiana and Illinois...
Growth of ponderosa pine stands in relation to mountain pine beetle susceptibility
R. A. Obedzinski; J. M. Schmid; S. A. Mata; W. K. Olsen; R. R. Kessler
1999-01-01
Ten-year diameter and basal area growth were determined for partially cut stands at 4 locations. Average diameters in the partially cut plots generally increased by 1 inch or more, while average diameter in the uncut controls increased by 0.9 inches or less. Individual tree growth is discussed in relation to potential susceptibility to mountain pine beetle infestation...
78 FR 62597 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... Block II missiles, 1000 GBU-39/B Small Diameter Bomb (SDB) with BRU-61 carriage systems, 40 CATM-84H... missiles, 1000 GBU-39/B Small Diameter Bombs (SDB), 40 CATM-84H Captive Air Training Missiles (CATM), 20... Small Diameter Bomb (SDB) I weapon is a 250-lb class, all-up round (AUR) that provides greater than 50nm...
78 FR 62594 - 36(b)(1) Arms Sales Notification
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... Consideration for Purchase: 5000 GBU-39/B Small Diameter Bombs (SDB) with BRU-61 carriage systems, 8 SDB Guided... Emirates has requested a possible sale of 5000 GBU-39/B Small Diameter Bombs (SDB) with BRU-61 carriage... environmental conditions. 5. The GBU-39/B Small Diameter Bomb (SDB) I weapon is a 250-lb class, all-up round...
Don C. Bragg
2002-01-01
This article is an introduction to the computer software used by the Potential Relative Increment (PRI) approach to optimal tree diameter growth modeling. These DOS programs extract qualified tree and plot data from the Eastwide Forest Inventory Data Base (EFIDB), calculate relative tree increment, sort for the highest relative increments by diameter class, and...
Analyzing The Uncertainty Of Diameter Growth Model Predictions
Ronald E. McRoberts; Veronica C. Lessard; Margaret R. Holdaway
1999-01-01
The North Central Research Station of the USDA Forest Service is developing a new set of individual tree, diameter growth models to be used as a component of an annual forest inventory system. The criterion for selection of predictor variables for these models is the uncertainty in 5-, 10-, and 20-year diameter growth predictions estimated using Monte Carlo simulations...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-07
... Project includes the following facilities: Pipeline Facilities the 5.3 miles, 20-inch-diameter TL-570, EXT... Greene County, Pennsylvania; the 42.3 mile 30-inch-diameter TL-590 pipeline in Marshall and Greene...; the 0.3 mile, 16-inch-diameter TL-598 pipeline in Harrison County, West Virginia; the 0.4 mile, 16...
Ronald E. McRoberts
2005-01-01
Uncertainty in model-based predictions of individual tree diameter growth is attributed to three sources: measurement error for predictor variables, residual variability around model predictions, and uncertainty in model parameter estimates. Monte Carlo simulations are used to propagate the uncertainty from the three sources through a set of diameter growth models to...
Status and trends of bottomland hardwood forests in the mid-Atlantic Region
Anita Rose; Steve Meadows
2016-01-01
Bottomland hardwood forests cover approximately 2.9 million acres of the Coastal Plain and Piedmont region of Virginia and North Carolina. As of 2014, 59 percent of bottomland hardwood forests were in the large-diameter stand-size class. Between 2002 and 2014, area of large-diameter sized stands increased, while that of medium- and small-diameter stands decreased,...
Comparison of Fixed Diameter-Limit and Selection Cutting in Northern Conifers
Laura S. Kenefic; Paul E. Sendak; John C. Brissette
2005-01-01
Diameter-limit cutting is a common type of harvest in which all merchantable trees above specific size thresholds are removed. Despite a long history of application, controlled experiments of these harvests are rare and the cumulative effects of repeated diameter-limit cuts are largely unknown. The Penobscot Experimental Forest in Maine is the location of a long-term...
Weight and volume equations and tables for six upland hardwoods in southern Illinois.
David J. Polak; Donald Raisanen; Richard C. Schlesinger; Les Stortz
1980-01-01
This paper presents tables of total tree green weight, green weight to a 5 cm and a 10 cm top diameter, dry weight to both 5 cm and 10 cm top diameter, and green volume to a 5 cm and 10 cm top diameter for six upland hardwood species. Both metric and English unit tables are included.
P.J. Peper; E.G. McPherson; S.M. Mori
2001-01-01
Although the modeling of energy-use reduction, air pollution uptake, rainfall interception, and microclimate modification associated with urban trees depends on data relating diameter at breast height (dbh) , crown height, crown diameter, and leaf area to tree age or dbh, scant information is available for common municipal tree species . I n this study , tree height ,...
J.M. Linton; H.M. Barnes; R.D. Seale; P.D. Jones; E. Lowell; S.S. Hummel
2010-01-01
Finding alternative uses for raw material from small-diameter trees is a critical problem throughout the United States. In western states, a lack of markets for small-diameter ponderosa pine (Pinus ponderosa) and lodgepole pine (Pinus contorta ) can contribute to problems associated with overstocking. To test the feasibility of...
Non-Ideal Detonation Properties of Ammonium Nitrate and Activated Carbon Mixtures
NASA Astrophysics Data System (ADS)
Miyake, Atsumi; Echigoya, Hiroshi; Kobayashi, Hidefumi; Ogawa, Terushige; Katoh, Katsumi; Kubota, Shiro; Wada, Yuji; Ogata, Yuji
To obtain a better understanding of detonation properties of ammonium nitrate (AN) and activated carbon (AC) mixtures, steel tube tests with several diameters were carried out for various compositions of powdered AN and AC mixtures and the influence of the charge diameter on the detonation velocity was investigated. The results showed that the detonation velocity increased with the increase of the charge diameter. The experimentally observed values were far below the theoretically predicted values made by the thermodynamic CHEETAH code and they showed so-called non-ideal detonation. The extrapolated detonation velocity of stoichiometric composition to the infinite diameter showed a good agreement with the theoretical value.
A solar diameter metrology measurement: the Picard microsatellite program
NASA Astrophysics Data System (ADS)
Damé, Luc; Brun, Jean-Francis; Cugnet, David; Derrien, Marc; Leroy, Claude; Meftah, Mustapha; Meissonnier, Mireille; Porteneuve, Jacques
2017-11-01
The PICARD microsatellite mission will provide 3 to 4 years simultaneous measurements of the solar diameter, differential rotation and solar constant to investigate the nature of their relations and variabilities. The major instrument, SODISM, is a whole Sun imaging telescope of Ø110 mm which will deliver an absolute measure (better than 4 mas) of the solar diameter and solar shape. Now in Phase B, PICARD is expected to be launched by 2005. We recall the scientific goals linked to the diameter measurement with interest for Earth Climate, Space Weather and Helioseismology, present the instrument optical concept and design, and give a brief overview of the program aspects.
Compressive buckling of black phosphorene nanotubes: an atomistic study
NASA Astrophysics Data System (ADS)
Nguyen, Van-Trang; Le, Minh-Quy
2018-04-01
We investigate through molecular dynamics finite element method with Stillinger-Weber potential the uniaxial compression of armchair and zigzag black phosphorene nanotubes. We focus especially on the effects of the tube’s diameter with fixed length-diameter ratio, effects of the tube’s length for a pair of armchair and zigzag tubes of equal diameters, and effects of the tube’s diameter with fixed lengths. Their Young’s modulus, critical compressive stress and critical compressive strain are studied and discussed for these 3 case studies. Compressive buckling was clearly observed in the armchair nanotubes. Local bond breaking near the boundary occurred in the zigzag ones under compression.
Ethylene Gas Sensing Properties of Tin Oxide Nanowires Synthesized via CVD Method
NASA Astrophysics Data System (ADS)
Akhir, Maisara A. M.; Mohamed, Khairudin; Rezan, Sheikh A.; Arafat, M. M.; Haseeb, A. S. M. A.; Uda, M. N. A.; Nuradibah, M. A.
2018-03-01
This paper studies ethylene gas sensing performance of tin oxide (SnO2) nanowires (NWs) as sensing material synthesized using chemical vapor deposition (CVD) technique. The effect of NWs diameter on ethylene gas sensing characteristics were investigated. SnO2 NWs with diameter of ∼40 and ∼240 nm were deposited onto the alumina substrate with printed gold electrodes and tested for sensing characteristic toward ethylene gas. From the finding, the smallest diameter of NWs (42 nm) exhibit fast response and recovery time and higher sensitivity compared to largest diameter of NWs (∼240 nm). Both sensor show good reversibility features for ethylene gas sensor.
Performance of 10-kW class xenon ion thrusters
NASA Technical Reports Server (NTRS)
Patterson, Michael J.; Rawlin, Vincent K.
1988-01-01
Presented are performance data for laboratory and engineering model 30 cm-diameter ion thrusters operated with xenon propellant over a range of input power levels from approximately 2 to 20 kW. Also presented are preliminary performance results obtained from laboratory model 50 cm-diameter cusp- and divergent-field ion thrusters operating with both 30 cm- amd 50 cm-diameter ion optics up to a 20 kW input power. These data include values of discharge chamber propellant and power efficiencies, as well as values of specific impulse, thruster efficiency, thrust and power. The operation of the 30 cm- and 50 cm-diameter ion optics are also discussed.
Shallow and deep fresh impact craters in Hesperia Planum, Mars
NASA Technical Reports Server (NTRS)
Mouginis-Mark, Peter J.; Hayashi, Joan N.
1993-01-01
The depths of 109 impact craters about 2-16 km in diameter, located on the ridged plains materials of Hesperia Planum, Mars, have been measured from their shadow lengths using digital Viking Orbiter images (orbit numbers 417S-419S) and the PICS computer software. On the basis of their pristine morphology (very fresh lobate ejecta blankets, well preserved rim crests, and lack of superposed impact craters), 57 of these craters have been selected for detailed analysis of their spatial distribution and geometry. We find that south of 30 deg S, craters less than 6.0 km in diameter are markedly shallower than similar-sized craters equatorward of this latitude. No comparable relationship is observed for morphologically fresh craters greater than 6.0 km diameter. We also find that two populations exist for older craters less than 6.0 km diameter. When craters that lack ejecta blankets are grouped on the basis of depth/diameter ratio, the deeper craters also typically lie equatorward of 30 S. We interpret the spatial variation in crater depth/diameter ratios as most likely due to a poleward increase in volatiles within the top 400 m of the surface at the times these craters were formed.
Laser-induced retinal injury thresholds: variation with retinal irradiated area
NASA Astrophysics Data System (ADS)
Lund, David J.; Schulmeister, Karl; Seiser, Bernhard; Edthofer, Florian
2005-04-01
The retinal injury threshold for exposure to a laser source varies as a function of the irradiated area on the retina. Currently accepted guidelines for the safe use of lasers provide that the MPE will increase as the diameter of the irradiated area for retinal diameters between 25 mm and 1700 mm, based on the ED50 data available in the late 1970s. Recent studies by Zuclich and Lund produced data showing that the ED50 for ns-duration exposures at 532 nm and ms duration exposures at 590 nm varied as the square of the diameter of the irradiated area on the retina. This paper will discuss efforts to resolve the disagreement between the new data and the earlier data though an analysis of all accessible data relating the retinal injury threshold to the diameter of the incident beam on the retina and through simulations using computer models of laser-induced injury. The results show that the retinal radiant exposure required to produce retinal injury is a function of both exposure duration and retinal irradiance diameter and that the current guidelines for irradiance diameter dependence do not accurately reflect the variation of the threshold data.
Calculation of laser pulse distribution maps for corneal reshaping with a scanning beam
NASA Astrophysics Data System (ADS)
Manns, Fabrice; Shen, Jin-Hui; Soederberg, Per G.; Matsui, Takaaki; Parel, Jean-Marie A.
1995-05-01
A method for calculating pulse distribution maps for scanning laser corneal surgery is presented. The accuracy, the smoothness of the corneal shape, and the duration of surgery were evaluated for corrections of myopia by using computer simulations. The accuracy and the number of pulses were computed as a function of the beam diameter, the diameter of the treatment zone, and the amount of attempted flattening. The ablation is smooth when the spot overlap is 80% or more. The accuracy does not depend on the beam diameter or on the diameter of the ablation zone when the ablation zone is larger than 5 mm. With an overlap of 80% and an ablation zone larger than 5 mm, the error is 5% of the attempted flattening, and 610 pulses are needed per Diopter of correction with a beam diameter of 1 mm. Pulse maps for the correction of astigmatism were computed and evaluated. The simulations show that with 60% overlap, a beam diameter of 1 mm, and a 5 mm treatment zone, 6 D of astigmatism can be corrected with an accuracy better than 1.8 D. This study shows that smooth and accurate ablations can be produced with a scanning spot.
A Fast Measuring Method for the Inner Diameter of Coaxial Holes
Wang, Lei; Yang, Fangyun; Fu, Luhua; Wang, Zhong; Yang, Tongyu; Liu, Changjie
2017-01-01
A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod’s rotation angles, so all diameters of coaxial holes can be calculated by sensors’ values. While revolving, the changing angles of each sensor’s laser beams are approximately equal in the rod’s radial direction so that the over-determined nonlinear equations of multi-layer holes for fitting circles can be established. The mathematical model of the measuring rod is established, all parameters that affect the accuracy of measurement are analyzed and simulated. In the experiment, the validity of the method is verified, the inner diameter measuring precision of 28 μm is achieved by 20 μm linearity LDS. The measuring rod has advantages of convenient operation and easy manufacture, according to the actual diameters of coaxial holes, and also the varying number of holes, LDS’s mounting location can be adjusted for different parts. It is convenient for rapid diameter measurement in industrial use. PMID:28327499
Duadi, Hamootal; Fixler, Dror; Popovtzer, Rachela
2013-11-01
Most methods for measuring light-tissue interactions focus on the volume reflectance while very few measure the transmission. We investigate both diffusion reflection and diffuse transmission at all exit angles to receive the full scattering profile. We also investigate the influence of blood vessel diameter on the scattering profile of a circular tissue. The photon propagation path at a wavelength of 850 nm is calculated from the absorption and scattering constants via Monte Carlo simulation. Several simulations are performed where a different vessel diameter and location were chosen but the blood volume was kept constant. The fraction of photons exiting the tissue at several central angles is presented for each vessel diameter. The main result is that there is a central angle that below which the photon transmission decreased for lower vessel diameters while above this angle the opposite occurred. We find this central angle to be 135 deg for a two-dimensional 10-mm diameter circular tissue cross-section containing blood vessels. These findings can be useful for monitoring blood perfusion and oxygen delivery in the ear lobe and pinched tissues. © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)
A Fast Measuring Method for the Inner Diameter of Coaxial Holes.
Wang, Lei; Yang, Fangyun; Fu, Luhua; Wang, Zhong; Yang, Tongyu; Liu, Changjie
2017-03-22
A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod's rotation angles, so all diameters of coaxial holes can be calculated by sensors' values. While revolving, the changing angles of each sensor's laser beams are approximately equal in the rod's radial direction so that the over-determined nonlinear equations of multi-layer holes for fitting circles can be established. The mathematical model of the measuring rod is established, all parameters that affect the accuracy of measurement are analyzed and simulated. In the experiment, the validity of the method is verified, the inner diameter measuring precision of 28 μm is achieved by 20 μm linearity LDS. The measuring rod has advantages of convenient operation and easy manufacture, according to the actual diameters of coaxial holes, and also the varying number of holes, LDS's mounting location can be adjusted for different parts. It is convenient for rapid diameter measurement in industrial use.
Lima, Robson B DE; Bufalino, Lina; Alves, Francisco T; Silva, José A A DA; Ferreira, Rinaldo L C
2017-01-01
Currently, there is a lack of studies on the correct utilization of continuous distributions for dry tropical forests. Therefore, this work aims to investigate the diameter structure of a brazilian tropical dry forest and to select suitable continuous distributions by means of statistic tools for the stand and the main species. Two subsets were randomly selected from 40 plots. Diameter at base height was obtained. The following functions were tested: log-normal; gamma; Weibull 2P and Burr. The best fits were selected by Akaike's information validation criterion. Overall, the diameter distribution of the dry tropical forest was better described by negative exponential curves and positive skewness. The forest studied showed diameter distributions with decreasing probability for larger trees. This behavior was observed for both the main species and the stand. The generalization of the function fitted for the main species show that the development of individual models is needed. The Burr function showed good flexibility to describe the diameter structure of the stand and the behavior of Mimosa ophthalmocentra and Bauhinia cheilantha species. For Poincianella bracteosa, Aspidosperma pyrifolium and Myracrodum urundeuva better fitting was obtained with the log-normal function.
Diameter and Geometry Control of Vertically Aligned SWNTs through Catalyst Manipulation
NASA Astrophysics Data System (ADS)
Xiang, Rong; Einarsson, Erik; Okawa, Jun; Murakami, Yoichi; Maruyama, Shigeo
2009-03-01
We present our recent progress on manipulating our liquid-based catalyst loading process, which possesses greater potential than conventional deposition in terms of cost and scalability, to control the diameter and morphology of single-walled carbon nanotubes (SWNTs). We demonstrate that the diameter of aligned SWNTs synthesized by alcohol catalytic CVD can be tailored over a wide range by modifying the catalyst recipe. SWNT arrays with an average diameter as small as 1.2 nm were obtained by this method. Additionally, owing to the alignment of the array, the continuous change of the SWNT diameter during a single CVD process can be clearly observed and quantitatively characterized. We have also developed a versatile wet chemistry method to localize the growth of SWNTs to desired regions via surface modification. By functionalizing the silicon surface using a classic self-assembled monolayer, the catalyst can be selectively dip-coated onto hydrophilic areas of the substrate. This technique was successful in producing both random and aligned SWNTs with various patterns. The precise control of the diameter and morphology of SWNTs, achieved by simple and scalable liquid-based surface chemistry, could greatly facilitate the application of SWNTs as the building blocks of future nano-devices.
Fan, Jiangxia; Zhu, Xinxin; Wang, Kunzhou; Chen, Xiaoyuan; Wang, Xinqing; Yan, Minhao; Ren, Yong
2018-05-01
We have fabricated highly ordered anodized aluminum oxide (AAO) membranes with different diameter through improved hard anodization (HA) at high temperature. This process can generate thick AAO membranes (30 μm) in a short anodizing time with high growth rate 20-60 μm h-1 which is much faster than that in traditional mild two-step anodization. We enlarged the AAO pore diameter by adjusting the voltage rise rate at the same time, which has a great influence on current density and temperature. The AAO pore diameter varies from 60-110 nm to 160-190 nm. The pore diameter (Dp) of the AAO prepared by this improved process is much larger than that prepared by HA (40-60 nm) when H2C2O4 as electrolyte. It can expand potential use of the AAO membranes such as for the template-based synthesis of nanowires or nanotubes with modulated diameters and also for practical separation technology. We also has used the AAO with different diameters prepared by this improved HA to fabricate Co nanowires and γ-Fe2O3 superparamagnetic nanorods.
Tortuosity correction of Kozeny's hydraulic diameter of a porous medium
NASA Astrophysics Data System (ADS)
Shin, C.
2017-02-01
The hydraulic diameter of a porous medium is the most important characteristic parameter governing porous flow aspects. Kozeny's hydraulic diameter has been used as the representative definition ever since he proposed it in 1927. However, it seems likely that this definition does not perfectly reflect the porous flow features even if the geometric relations of porous media are reasonably considered. Here we reviewed its definition by introducing Darcy's friction flow relation, and discovered that the term "tortuosity" should be included in the definition to more accurately characterize porous flows. Thus, the definition of "Tortuous Hydraulic Diameter (THD)," which corrects Kozeny's hydraulic diameter using tortuosity, is newly presented. Moreover, computational fluid dynamics simulations were performed to check the validity and applicability of the THD approach. As a result, it is seen that the THD demonstrates very low errors, with an average of 1.67%, whereas Kozeny's definition has relatively large errors, with an average of 12.8%. Accordingly, it is confirmed that the THD relation is the more accurate hydraulic diameter definition for a porous medium. Ultimately, the corrected definition can contribute to more reliable determinations of the other characteristic parameters and more reasonable porous flow analyses.
NASA Technical Reports Server (NTRS)
Re, Richard J.; Abeyounis, William K.
1993-01-01
Pressure distributions on three inlets having different cowl lengths were obtained in the Langley 16-Foot Transonic Tunnel. The cowl diameter ratio (highlight diameter to maximum diameter) was 0.85 and the cowl length ratios (cowl length to maximum diameter) were 0.337, 0.439, and 0.547. The cowls had identical nondimensionalized (with respect to cowl length) external geometry and identical internal geometry. The internal contraction ratio (highlight area to throat area) was 1.250. The inlets had longitudinal rows of static pressure orifices on the top and bottom (external) surfaces and on the contraction (internal) and diffuser surfaces. The afterbody was cylindrical in shape, and its diameter was equal to the maximum diameter of the cowl. Depending on the cowl configuration and free-stream Mach number, the mass-flow ratio varied between 0.27 and 0.87 during the tests. Angle of attack varied from 0 to 4.1 deg at selected Mach numbers and mass-flow ratios, and the Reynolds number varied with the Mach number from 3.2x10(exp 6) to 4.2x10(exp 6) per foot.
NASA Astrophysics Data System (ADS)
Dwi Hastuti, Endah; Budi Hastuti, Rini
2018-03-01
Dynamic environment condition of the silvofishery pond should provide an effect on the growth of mangrove seedling. This research aimed to observe the morphometric growth rate of mangrove seedling of Avicennia marina and Rhizophora mucronata planted in the silvofishery pond and to analyze the morphometric growth relationship of height, diameter and leaf number development of mangrove seedling. The research was conducted through field experiment involving mangrove species of A. marina and R. mucronata for 18 months during March 2015 to September 2016, both single structured and mixed structure. The observation was conducted every 13 weeks including seedling height, diameter and number of leaves. Data analysis was conducted by regression to provide the statistical relation between the growth of diameter – height, diameter – number of leaves and height – number of leaves. The result showed that the growth rate of A. marina in single structured pond was ranged from 0.38 – 3.00 cm.wk-1, 0.0015 – 0.0969 cm.wk‑1 and 0.1 – 13.7 leaves.wk‑1 respectively for height, diameter and number of leaves, while in mixed structure was 0.23 – 1.69 cm.wk‑1, 0.0169 – 0.0731 cm.wk‑1 and 0.5 – 14.0 leaves.wk-. The growth of R. mucronata respectively in single and mixed structure were 0.08 – 2.00 cm.wk‑1 and 0.15 – 2.62 cm.wk‑1, 0.0031 – 0.1369 cm.wk‑1 and 0.0008 – 0.0831 cm.wk‑1 and 0.0 – 1.9 leaves.wk‑1 and 0.0 – 1.6 leaves.wk-1respectively for height, diameter and number of leaves. Data analysis showed that the growth of seedling height of Avicennia in the mixed structure was significantly affected by its diameter growth and the number of leaves of Avicennia in single structured was significantly affected by its diameter. While the height, diameter and number of leaves of R. mucronata both in mixed and single structured silvofishery ponds were independent to each other. This research concluded that mangrove seedling growth is varied among species and growth environment.
Aortoiliac morphologic correlations in aneurysms undergoing endovascular repair.
Ouriel, Kenneth; Tanquilut, Eugene; Greenberg, Roy K; Walker, Esteban
2003-08-01
The feasibility of endovascular aneurysm repair depends on morphologic characteristics of the aortoiliac segment. Knowledge of such characteristics is relevant to safe deployment of a particular device in a single patient and to development of new devices for use in patients with a broader spectrum of anatomic variations. We evaluated findings on computed tomography scans for 277 patients being considered for endovascular aneurysm repair. Aortic neck length and angulation estimates were generated with three-dimensional trigonometry. Specific centerline points were recorded, corresponding to the aorta at the celiac axis, lowest renal artery, cranial aspect of the aneurysm sac, aortic terminus, right hypogastric artery origin, and left hypogastric origin. Aortic neck thrombus and calcium content were recorded, and neck conicity was calculated in degrees. Statistical analysis was performed with the Spearman rank correlation. Data are expressed as median and interquartile range. Median diameter of the aneurysms was 52 mm (interquartile range, 48-59 mm) in minor axis and 56 mm (interquartile range, 51-64 mm) in major axis, and median length was 88 mm (interquartile range, 74-103 mm). Median proximal aortic neck diameter was 26 mm (interquartile range, 22-29 mm), and median neck length was 30 mm (interquartile range, 18-45 mm). The common iliac arteries were similar in diameter (right artery, 16 mm [interquartile range, 13-20 mm]; left artery, 15 mm [interquartile range, 11-18 mm]) and length (right, 59 mm [interquartile range, 50-69 mm]; left, 60 mm [interquartile range, 49-70 mm]). Median angulation of the infrarenal aortic neck was 40 degrees (interquartile range, 29-51 degrees), and median angulation of the suprarenal segment was 45 degrees (interquartile range, 36-57 degrees). By gender, sac diameter, proximal neck diameter, and iliac artery diameter were significantly larger in men. Significant linear associations were identified between sac diameter and sac length, neck angulation, and iliac artery diameter. As the length of the aneurysm sac increased the proximal aortic neck length decreased. Conversely, as the sac length decreased sac eccentricity increased. Mural thrombus content within the neck increased with increasing neck diameter. There is considerable variability in aortoiliac morphologic parameters. Significant associations were found between various morphologic variables, links that are presumably related to a shared pathogenesis for aberration in aortoiliac diameter, length, and angulation. Ultimately this information can be used to develop new endovascular devices with broader applicability and improved long-term results.
NASA Astrophysics Data System (ADS)
Cai, Yunshen
Electrospinning produces submicron fibers from a wide range of polymer/solvent systems that enable a variety of different applications. In electrospinning process, a straight polymer/solvent charged jet is initially formed, followed by a circular moving jet in the shape of a cone, called the bending region. The process physics in the bending region are difficult to study since the jet diameter cannot be measured directly due to its rapid motion and small size ( microns and smaller), and due to complex coupling of multiple forces, mass transport, and changing jet geometry. Since the solutions studied are hydrophilic, they readily absorb ambient moisture. This thesis explores the role of the bending region in determining the resulting electrospun fiber diameter through a combined experimental and modeling analysis for a variety of hydrophilic polymer/solvent solutions. Electrospinning experiments were conducted over a broad range of operating conditions for 4 different polymer/solvent systems. Comparison of the final straight jet diameters to fiber diameters reveals that between 30% to 60% jet thinning occurs in the bending region. These experiments also reveal that relative humidity significantly affects the electrospinning process and final fiber diameter, even for non-aqueous solutions. A model is developed to obtain insight into the bending region process physics. Important ones include understanding the mass transport for non-aqueous hydrophilic jets (including solvent evaporation and water absorption on the jet surface, radial diffusion, and axial advection), and the coupling between the mass and force balances that determines the final fiber diameter. The absorption and evaporation physics is validated by evaporation experiments. The developed model predicts fiber diameter to within of 8%, even though the solution properties and operating conditions that determines net stretching forces and net evaporation rates vary over a large range. Model analysis reveals how the net evaporation rate affects the jet length and net stretching force, both of which ultimately determine the fiber diameter. It is also shown that the primary impact of RH on the process is through occupation of the surface states that limits solvent evaporation rate, rather than the amount of water absorbed. Correlation functions between process conditions, solution properties and the resulting fiber diameters are discussed.
Nagata, Keiji; Yoshimura, Noriko; Hashizume, Hiroshi; Muraki, Shigeyuki; Ishimoto, Yuyu; Yamada, Hiroshi; Takiguchi, Noboru; Nakagawa, Yukihiro; Minamide, Akihito; Oka, Hiroyuki; Kawaguchi, Hiroshi; Nakamura, Kozo; Akune, Toru; Yoshida, Munehito
2014-12-01
A narrow cervical spinal canal (CSC) is a well-known risk factor for cervical myelopathy (CM). However, no epidemiologic data of the CSC based on a population-based cohort are available. The purpose of the study was to investigate the age-related differences in CSC diameters on plain radiographs and to examine the associated magnetic resonance imaging (MRI) abnormalities including cervical cord compression and increased signal intensity (ISI) as well as the clinical CM with the narrow CSC. This was a cross-sectional study. Data were obtained from the baseline survey of the Wakayama Spine Study that was performed from 2008 to 2010 in a western part of Japan. Finally, a total of 959 subjects (319 men and 640 women; mean age, 66.4 years) were included. The outcome measures included in the study were the CSC diameter at C5 level on plain radiographs, cervical cord compression and ISI on sagittal T2-weighted MRI, and physical signs related to CM (eg, the Hoffmann reflex, hyperreflexia of the patellar tendon, the Babinski reflex, sensory and motor function, and bowel/bladder symptoms). The age-related differences of CSC diameters in men and women were investigated by descriptive statistics. The prevalence of MRI abnormalities and clinical CM was compared among the groups divided by the CSC diameter (less than 13, 13-15, and 15 mm or more). In addition, a logistic regression analysis was performed to determine the association of the CSC diameter with cervical cord compression/clinical CM after overall adjustment for age, sex, and body mass index. The CSC diameter was narrower with increasing age in both men and women. The prevalence of cervical cord compression, ISI, and the clinical CM was significantly higher in the narrower CSC group. The prevalence of cervical cord compression, ISI, and CM among subjects with CSC diameter less than 13 mm was 38.0%, 5.4%, and 10.1%, respectively. In the logistic model, the CSC diameter was a significant predictive factor for the clinical CM (p<.0001). This study firstly confirmed the age-related differences in CSC diameters and the significant association of the narrow CSC diameter with CM in a population-based cohort. Copyright © 2014 Elsevier Inc. All rights reserved.
Feder, Idit; Duadi, Hamootal; Dreifuss, Tamar; Fixler, Dror
2016-10-01
Optical methods for detecting physiological state based on light-tissue interaction are noninvasive, inexpensive, simplistic, and thus very useful. The blood vessels in human tissue are the main cause of light absorbing and scattering. Therefore, the effect of blood vessels on light-tissue interactions is essential for optically detecting physiological tissue state, such as oxygen saturation, blood perfusion and blood pressure. We have previously suggested a new theoretical and experimental method for measuring the full scattering profile, which is the angular distribution of light intensity, of cylindrical tissues. In this work we will present experimental measurements of the full scattering profile of heterogenic cylindrical phantoms that include blood vessels. We show, for the first time that the vessel diameter influences the full scattering profile, and found higher reflection intensity for larger vessel diameters accordance to the shielding effect. For an increase of 60% in the vessel diameter the light intensity in the full scattering profile above 90° is between 9% to 40% higher, depending on the angle. By these results we claim that during respiration, when the blood-vessel diameter changes, it is essential to consider the blood-vessel diameter distribution in order to determine the optical path in tissues. A CT scan of the measured silicon-based phantoms. The phantoms contain the same blood volume in different blood-vessel diameters. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A study on fatigue strength reduction factor for small diameter socket welded pipe joints
DOE Office of Scientific and Technical Information (OSTI.GOV)
Higuchi, Makoto; Nakagawa, Akira; Hayashi, Makoto
1996-12-01
Factors that may exert influence on the fatigue strength of small diameter socket welded joints of nominal diameter in the 20--50 mm range have been investigated by the fully reversed four-point bending fatigue test with the material, diameter, pipe schedule, throat depth, bead shape, slip-on gap, and root defect as the testing parameters. The fatigue strength of socket joints depended acutely on the diameter. When the diameter is large, the fatigue strength tended to be low and the fracture is of the root-failure mode; when it is small, on the other hand, the fatigue strength is high and the fracturemore » is of the toe-failure mode. Stainless steel proved to be superior to carbon steel; it gave rise to 1.37 times the fatigue strength of the latter for socket joints of nominal diameter 50 mm; the fatigue strength reduction factor determined at 10{sup 7} cycles with respect to the fatigue strength of smooth base metal in the fully reversed fatigue was about 4 for stainless steel and about 5 for carbon steel. The fatigue strength was higher, the larger the Sche number (i.e., the thicker the pipe wall); it was improved markedly by placing one final refinement pass on the toe or by eliminating the slip-on gap. An empirical formula relating the size of the root defect to the fatigue strength reduction has been proposed.« less
NASA Astrophysics Data System (ADS)
He, Feng-Li; He, Jin; Deng, Xudong; Li, Da-Wei; Ahmad, Fiaz; Liu, Yang-Yang; Liu, Ya-Li; Ye, Ya-Jing; Zhang, Chen-Yan; Yin, Da-Chuan
2017-10-01
Melt electrospinning is a complex process, and many of the processing parameters can impact the result of fiber formation. In this paper, we conducted a systematic investigation on the impacts of the melt electrospinning parameters (including temperature, needle gauge, flow rate and collector speed) on the fiber diameter via an orthogonal design experiment. The straight single fibers were fabricated using melt electrospinning in a direct-writing way with a diameter varied from 9.68 ± 0.93 µm to 48.55 ± 3.72 µm. The results showed that the fiber diameter changed differently against different parameters: when the temperature or needle gauge increased, the fiber diameter increased first and then decreased; when the flow rate increased, the fiber diameter decreased first and then increased; when the collector speed increased, the fiber diameter decreased monotonously. We also found that the collector speed was the most influential factor while the needle gauge was least important in determining the diameter of the fiber. Moreover, the feasibility of melt electrospinning in a direct-writing way as a novel 3D printing technology had been demonstrated by fabricating both uniform and controllable structures with high accuracy, based on the optimal parameters from the orthogonal experiments. The promising results indicated that melt electrospinning can be developed as a powerful technique for fabricating miniatured parts with high resolution and controllable structures for versatile potential applications.
Does endothelial cell density correlate with corneal diameter in a group of young adults?
Giasson, Claude J; Gosselin, Lucie; Masella, Aviva; Forcier, Pierre
2008-07-01
In children, but not in the elderly, an association exists between corneal diameter and endothelial cell density (ECD). We tested whether such an association also held true in young adults. The eyes of 35 healthy subjects (mean age, 23.1 +/- 3.1 years) were photographed by using a video camera and a noncontact endothelial microscope. Both sets of images were analyzed with image software and the contour method to measure corneal diameter, ECD, and endothelial coefficients. Axial lengths, refractive errors, and corneal curvatures were measured by using an A-scan ultrasonic biometer and kerato-refractometer. Measurements, averaged for the right and left eyes, were analyzed depending on (1) use of contact lenses, (2) ametropia, and on whether (3) axial length or (4) corneal diameter was above or below group means. Differences were tested for statistical significance with independent t tests and association with the Pearson correlation coefficient. ECD, corneal diameter, and spherical equivalent refraction were 3022 +/- 262 cells/mm2, 12.0 +/- 0.5 mm, and -3.1 +/- 2.5 D, respectively. The only significant differences between wearers and nonwearers of contact lenses were the spherical refractive equivalent and axial length. There was no correlation between ECD and corneal diameter or axial length. As opposed to previously reported results in children, but as found in the elderly, there is no correlation between ECD and corneal diameter in young adults. Therefore, corneal size cannot be considered a determinant of ECD in young adults.
Wear versus Thickness and Other Features of 5-Mrad Crosslinked UHMWPE Acetabular Liners
Shen, Fu-Wen; Lu, Zhen
2010-01-01
Background The low wear rates of crosslinked polyethylenes provide the potential to use larger diameters to resist dislocation. However, this requires the use of thinner liners in the acetabular component, with concern that higher contact stresses will increase wear, offsetting the benefits of the crosslinking. Questions/purposes We asked the following questions: Is the wear of conventional and crosslinked polyethylene liners affected by ball diameter, rigidity of backing, and liner thickness? Are the stresses in the liner affected by thickness? Methods Wear rates were measured in a hip simulator and stresses were calculated using finite element modeling. Results Without crosslinking, the wear rate was 4% to 10% greater with a 36-mm diameter than a 28-mm diameter. With crosslinking, wear was 9% lower with a 36-mm diameter without metal backing and 4% greater with metal backing. Reducing the thickness from 6 mm to 3 mm increased the contact stress by 46%, but the wear rate decreased by 19%. Conclusions The reduction in wear with 5 Mrad of crosslinking was not offset by increasing the diameter from 28 mm to 36 mm or by using a liner as thin as 3 mm. Clinical Relevance The results indicate, for a properly positioned 5-Mrad crosslinked acetabular component and within the range of dimensions evaluated, neither wear nor stresses in the polyethylene are limiting factors in the use of larger-diameter, thinner cups to resist dislocation. PMID:20848244
Wilmshurst, Peter T; Morrison, W Lindsay; Walsh, Kevin P
2015-06-01
Decompression illness (DCI) is associated with a right-to-left shunt, such as persistent foramen ovale (PFO), atrial septal defect (ASD) and pulmonary arteriovenous malformations. About one-quarter of the population have a PFO, but considerably less than one-quarter of divers suffer DCI. Our aim was to determine whether shunt-related DCI occurs mainly or entirely in divers with the largest diameter atrial defects. Case control comparison of diameters of atrial defects (PFO and ASD) in 200 consecutive divers who had transcatheter closure of an atrial defect following shunt-related DCI and in an historic group of 263 individuals in whom PFO diameter was measured at post-mortem examination. In the divers who had experienced DCI, the median atrial defect diameter was 10 mm and the mean (standard deviation) was 9.9 (3.6) mm. Among those in the general population who had a PFO, the median diameter was 5 mm and mean was 4.9 (2.6) mm. The difference between the two groups was highly significant (P < 0.0001). Of divers with shunt-related DCI, 101 (50.5%) had an atrial defect 10 mm diameter or larger, but only 1.3% of the general population studied had a PFO that was 10 mm diameter of larger. The risk of a diver suffering DCI is related to the size of the atrial defect rather than just the presence of a defect.
NASA Astrophysics Data System (ADS)
Pakula, Anna; Tomczewski, Slawomir; Skalski, Andrzej; Biało, Dionizy; Salbut, Leszek
2010-05-01
This paper presents novel application of Low Coherence Interferometry (LCI) in measurements of characteristic parameters as circular pitch, foot diameter, heads diameter, in extremely small cogged wheels (cogged wheel diameter lower than θ=3 mm and module m = 0.15) produced from metal and ceramics. The most interesting issue concerning small diameter cogged wheels occurs during their production. The characteristic parameters of the wheel depend strongly on the manufacturing process and while inspecting small diameter wheels the shrinkage during the cast varies with the slight change of fabrication process. In the paper the LCI interferometric Twyman - Green setup with pigtailed high power light emitting diode, for cogged wheels measurement, is described. Due to its relatively big field of view the whole wheel can be examined in one measurement, without the necessity of numerical stitching. For purposes of small cogged wheel's characteristic parameters measurement the special binarization algorithm was developed and successfully applied. At the end the results of measurement of heads and foot diameters of two cogged wheels obtained by proposed LCI setup are presented and compared with the results obtained by the commercial optical profiler. The results of examination of injection moulds used for fabrication of measured cogged wheels are also presented. Additionally, the value of cogged wheels shrinkage is calculated as a conclusion for obtained results. Proposed method is suitable for complex measurements of small diameter cogged wheels with low module especially when there are no measurements standards for such objects.
Primary and Aggregate Size Distributions of PM in Tail Pipe Emissions form Diesel Engines
NASA Astrophysics Data System (ADS)
Arai, Masataka; Amagai, Kenji; Nakaji, Takayuki; Hayashi, Shinji
Particulate matter (PM) emission exhausted from diesel engine should be reduced to keep the clean air environment. PM emission was considered that it consisted of coarse and aggregate particles, and nuclei-mode particles of which diameter was less than 50nm. However the detail characteristics about these particles of the PM were still unknown and they were needed for more physically accurate measurement and more effective reduction of exhaust PM emission. In this study, the size distributions of solid particles in PM emission were reported. PMs in the tail-pipe emission were sampled from three type diesel engines. Sampled PM was chemically treated to separate the solid carbon fraction from other fractions such as soluble organic fraction (SOF). The electron microscopic and optical-manual size measurement procedures were used to determine the size distribution of primary particles those were formed through coagulation process from nuclei-mode particles and consisted in aggregate particles. The centrifugal sedimentation method was applied to measure the Stokes diameter of dry-soot. Aerodynamic diameters of nano and aggregate particles were measured with scanning mobility particle sizer (SMPS). The peak aggregate diameters detected by SMPS were fallen in the same size regime as the Stokes diameter of dry-soot. Both of primary and Stokes diameters of dry-soot decreased with increases of engine speed and excess air ratio. Also, the effects of fuel properties and engine types on primary and aggregate particle diameters were discussed.
NASA Astrophysics Data System (ADS)
Saffari, H.; Moosavi, R.
2014-11-01
In this article, turbulent single-phase and two-phase (air-water) bubbly fluid flows in a vertical helical coil are analyzed by using computational fluid dynamics (CFD). The effects of the pipe diameter, coil diameter, coil pitch, Reynolds number, and void fraction on the pressure loss, friction coefficient, and flow characteristics are investigated. The Eulerian-Eulerian model is used in this work to simulate the two-phase fluid flow. Three-dimensional governing equations of continuity, momentum, and energy are solved by using the finite volume method. The k- ɛ turbulence model is used to calculate turbulence fluctuations. The SIMPLE algorithm is employed to solve the velocity and pressure fields. Due to the effect of a secondary force in helical pipes, the friction coefficient is found to be higher in helical pipes than in straight pipes. The friction coefficient increases with an increase in the curvature, pipe diameter, and coil pitch and decreases with an increase in the coil diameter and void fraction. The close correlation between the numerical results obtained in this study and the numerical and empirical results of other researchers confirm the accuracy of the applied method. For void fractions up to 0.1, the numerical results indicate that the friction coefficient increases with increasing the pipe diameter and keeping the coil pitch and diameter constant and decreases with increasing the coil diameter. Finally, with an increase in the Reynolds number, the friction coefficient decreases, while the void fraction increases.
Flue gas adsorption by single-wall carbon nanotubes: A Monte Carlo study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romero-Hermida, M. I.; Departamento de Física Condensada, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla; Romero-Enrique, J. M.
Adsorption of flue gases by single-wall carbon nanotubes (SWCNT) has been studied by means of Monte Carlo simulations. The flue gas is modeled as a ternary mixture of N{sub 2}, CO{sub 2}, and O{sub 2}, emulating realistic compositions of the emissions from power plants. The adsorbed flue gas is in equilibrium with a bulk gas characterized by temperature T, pressure p, and mixture composition. We have considered different SWCNTs with different chiralities and diameters in a range between 7 and 20 Å. Our results show that the CO{sub 2} adsorption properties depend mainly on the bulk flue gas thermodynamic conditionsmore » and the SWCNT diameter. Narrow SWCNTs with diameter around 7 Å show high CO{sub 2} adsorption capacity and selectivity, but they decrease abruptly as the SWCNT diameter is increased. For wide SWCNT, CO{sub 2} adsorption capacity and selectivity, much smaller in value than for the narrow case, decrease mildly with the SWCNT diameter. In the intermediate range of SWCNT diameters, the CO{sub 2} adsorption properties may show a peculiar behavior, which depend strongly on the bulk flue gas conditions. Thus, for high bulk CO{sub 2} concentrations and low temperatures, the CO{sub 2} adsorption capacity remains high in a wide range of SWCNT diameters, although the corresponding selectivity is moderate. We correlate these findings with the microscopic structure of the adsorbed gas inside the SWCNTs.« less
Nitric oxide regulates retinal vascular tone in humans.
Dorner, Guido T; Garhofer, Gerhard; Kiss, Barbara; Polska, Elzbieta; Polak, Kaija; Riva, Charles E; Schmetterer, Leopold
2003-08-01
The purpose of the present study was to investigate the contribution of basal nitric oxide (NO) on retinal vascular tone in humans. In addition, we set out to elucidate the role of NO in flicker-induced retinal vasodilation in humans. Twelve healthy young subjects were studied in a three-way crossover design. Subjects received an intravenous infusion of either placebo or NG-monomethyl-L-arginine (L-NMMA; 3 or 6 mg/kg over 5 min), an inhibitor of NO synthase. Thereafter, diffuse luminance flicker was consecutively performed for 16, 32, and 64 s at a frequency of 8 Hz. The effect of L-NMMA on retinal arterial and venous diameter was assessed under resting conditions and during the hyperemic flicker response. Retinal vessel diameter was measured with a Zeiss retinal vessel analyzer. L-NMMA significantly reduced arterial diameter (3 mg/kg: -2%; 6 mg/kg: -4%, P < 0.001) and venous diameter (3 mg/kg: -5%; 6 mg/kg: -8%, P < 0.001). After placebo infusion, flicker induced a significant increase in retinal vessel diameter (P < 0.001). At a flicker duration of 64 s, arterial diameter increased by 4% and venous diameter increased by 3%. L-NMMA did not abolish these hyperemic responses but blunted venous vasodilation (P = 0.017) and arterial vasodilation (P = 0.02) in response to flicker stimulation. Our data indicate that NO contributes to basal retinal vascular tone in humans. In addition, NO appears to play a role in flicker-induced vasodilation of the human retinal vasculature.
Frank, C; Bray, D; Rademaker, A; Chrusch, C; Sabiston, P; Bodie, D; Rangayyan, R
1989-01-01
To establish a normal baseline for comparison, thirty-one thousand collagen fibril diameters were measured in calibrated transmission electron (TEM) photomicrographs of normal rabbit medial collateral ligaments (MCL's). A new automated method of quantitation was used to compare statistically fibril minimum diameter distributions in one midsubstance location in both MCL's from six animals at 3 months of age (immature) and three animals at 10 months of age (mature). Pooled results demonstrate that rabbit MCL's have statistically different (p less than 0.001) mean minimum diameters at these two ages. Interanimal differences in mean fibril minimum diameters were also significant (p less than 0.001) and varied by 20% to 25% in both mature and immature animals. Finally, there were significant differences (p less than 0.001) in mean diameters and distributions from side-to-side in all animals. These mean left-to-right differences were less than 10% in all mature animals but as much as 62% in some immature animals. Statistical analysis of these data demonstrate that animal-to-animal comparisons using these protocols require a large number of animals with appropriate numbers of fibrils being measured to detect small intergroup differences. With experiments which compare left to right ligaments, far fewer animals are required to detect similarly small differences. These results demonstrate the necessity for rigorous control of sampling, an extensive normal baseline and statistically confirmed experimental designs in any TEM comparisons of collagen fibril diameters.
Marie Yee; Simon J. Grove; Alastair M.M. Richardson; Caroline L. Mohammed
2006-01-01
It is not clear why large diameter logs generally host saproxylic beetle assemblages that are different from those of small diameter logs. In a study in Tasmanian wet eucalypt forest, two size-classes of Eucalyptus obliqua logs (>100cm and 30-60cm diameter) were destructively sampled to assess their beetle fauna and the associations of this fauna...
Estimating past diameters of ponderosa pine in northern California
Robert F. Powers
1969-01-01
Past outside bark diameters (d.o.b.) of ponderosa pine in northern California can be estimated from the relation of bark thickness to stem diameter. An equation for estimating past d.o.b.'s has been developed. The relationship appears to be linear between 1 and 20 inches d.o.b. and differs from ratios reported for the species in other areas. Site quality and crown...
Brian Perkins; Bob Smith; Philip Araman
2008-01-01
The eastern hardwood forest contains small diameter timber that is often of lower quality and lower value than larger sawtimber. This small diameter hardwood timber has traditionally been utilized for pulpwood, but it can also be used for lumber and residue production. In order to increase the utilization of this resource by sawmills, a number of analyses need to be...
Michael J. Falkowski; Alistair M.S. Smith; Andrew T. Hudak; Paul E. Gessler; Lee A. Vierling; Nicholas L. Crookston
2006-01-01
We describe and evaluate a new analysis technique, spatial wavelet analysis (SWA), to automatically estimate the location, height, and crown diameter of individual trees within mixed conifer open canopy stands from light detection and ranging (lidar) data. Two-dimensional Mexican hat wavelets, over a range of likely tree crown diameters, were convolved with lidar...
J.M. Schmid; S.A. Mata; R.R. Kessler; J.B. Popp
2007-01-01
Ponderosa pine stands were partially cut to various stocking levels at five locations, periodically surveyed, and remeasured during the 20 years after installation. Mean diameter generally increased 2 inches over the 20-year period on most partially cut plots and less than 2 inches on unmanaged controls. Average diameter growth for diameter classes in partially cut...
Diameter growth of trees in an uneven-aged oak forest in the Missouri Ozarks
Edward F. Loewenstein; Paul S. Johnson; Harold E. Garrett
1997-01-01
We tested the efficacy of even-aged stand tables for predicting diameter growth of trees in uneven-aged oak stands. The study was based on the age- and diameter-structure of the Pioneer Forest, a 156,000-acre, privately owned oak forest in the Ozark Highlands of Missouri. The forest has been managed by single-tree selection since 1954.
Individual-tree diameter growth model for managed, even-aged, upland oak stands
Donald E. Hilt
1983-01-01
A distance-independent, individual-tree diameter growth model was developed for managed, even-aged, upland oak stands. The 5-year basal-area growth of individual trees is first modeled as a function of dbh squared for given stands. Parameters from these models are then modeled as a function of mean stand diameter, percent stocking of the stand, and site index. A...
Height-diameter equations for young-growth red fir in California and southern Oregon
K. Leroy Dolph
1989-01-01
Total tree height of young-growth red fir can be estimated from the relation of total tree height to diameter outside bark at breast height (DOB). Total tree heights and corresponding diameters were obtained from stem analyses of 562 trees distributed across 56 sampling locations in the true fir forest type of California and Oregon. The resulting equations can predict...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... Reservoir with a storage capacity of 9,700-acre-foot; (4) a 3,800-foot-long, 18.7-foot-diameter concrete-lined pressure shaft; (5) a 200-foot-long, 22.4-foot-diameter concrete-lined tailrace; (6) a 280-foot...,700-acre-foot; (4) a 800-foot-long, 20.4-foot-diameter unlined or concrete-lined low-pressure tunnel...
Nanogrid rolling circle DNA sequencing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Church, George M.; Porreca, Gregory J.; Shendure, Jay
The present invention relates to methods for sequencing a polynucleotide immobilized on an array having a plurality of specific regions each having a defined diameter size, including synthesizing a concatemer of a polynucleotide by rolling circle amplification, wherein the concatemer has a cross-sectional diameter greater than the diameter of a specific region, immobilizing the concatemer to the specific region to make an immobilized concatemer, and sequencing the immobilized concatemer.
Evaluating growth assumptions using diameter or radial increments in natural even-aged longleaf pine
John C. Gilbert; Ralph S. Meldahl; Jyoti N. Rayamajhi; John S. Kush
2010-01-01
When using increment cores to predict future growth, one often assumes future growth is identical to past growth for individual trees. Once this assumption is accepted, a decision has to be made between which growth estimate should be used, constant diameter growth or constant basal area growth. Often, the assumption of constant diameter growth is used due to the ease...
Estimating air-drying times of small-diameter ponderosa pine and Douglas-fir logs
William T. Simpson; Xiping Wang
2004-01-01
One potential use for small-diameter ponderosa pine and Douglas-fir timber is in log form. Many potential uses of logs require some degree of drying. Even though these small diameters may be considered small in the forestry context, their size when compared to typical lumber thickness dimensions is large. These logs, however, may require uneconomically long kiln-drying...
A comparison of pine height models for the Crossett Experimental Forest
D. Bragg
2008-01-01
Many models to predict tree height from diameter have been developed, but not all are equally useful. This study compared a set of height diameter models for loblolly (Pinus taeda) and shortleaf (Pinus echinata) pines from Ashley County, Arkansas. Almost 560 trees ranging in diameter at breast height (DBH) from 0.3 cm (both species) to 91.9 cm (for shortleaf) or 108.2...
Solar diameter measurements for study of Sun climate coupling
NASA Technical Reports Server (NTRS)
Hill, H. A.
1981-01-01
Variability in solar shape and diameters was examined as a possible probe of an important climatic driving function, solar luminosity variability. The techniques and facilities developed for measuring the solar diameter were used. The observing program and the requisite data reduction were conducted simultaneously. The development of a technique to calibrate the scale in the telescope field progressed to the design and construction phase.
Height-Diameter Equations for 12 Upland Species in the Missouri Ozark Highlands
J.R. Lootens; David R. Larsen; Stephen R. Shifley
2007-01-01
We calibrated a model predicting total tree height as a function of tree diameter for nine tree species common to the Missouri Ozarks. Model coefficients were derived from nearly 10,000 observed trees. The calibrated model did a good job predicting the mean height-diameter trend for each species (pseudo-R2 values ranged from 0.56 to 0.88), but...
Jingjing Liang; J. Buongiorno; R.A. Monserud
2005-01-01
A growth model for uneven-aged mixed-conifer stands in California was developed with data from 205 permanent plots. The model predicts the number of softwood and hardwood trees in nineteen diameter classes, based on equations for diameter growth rates, mortality arid recruitment. The model gave unbiased predictions of the expected number of trees by diameter class and...
46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.
Code of Federal Regulations, 2014 CFR
2014-10-01
... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...
46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.
Code of Federal Regulations, 2012 CFR
2012-10-01
... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...
46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.
Code of Federal Regulations, 2010 CFR
2010-10-01
... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...
46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.
Code of Federal Regulations, 2011 CFR
2011-10-01
... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...
46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.
Code of Federal Regulations, 2013 CFR
2013-10-01
... worn down to 6.4 mm (0.25 in) clearance for shafts of 229 mm (9 in) or less in diameter, 7.95 mm (0.3125 in) clearance for shafts exceeding 229 mm (9 in) but not exceeding 305 mm (12 in) in diameter, and 9.53 mm (0.375 in) clearance for shafts exceeding 305 mm (12 in) in diameter. (2) Where the...
Measuring Diameters Of Large Vessels
NASA Technical Reports Server (NTRS)
Currie, James R.; Kissel, Ralph R.; Oliver, Charles E.; Smith, Earnest C.; Redmon, John W., Sr.; Wallace, Charles C.; Swanson, Charles P.
1990-01-01
Computerized apparatus produces accurate results quickly. Apparatus measures diameter of tank or other large cylindrical vessel, without prior knowledge of exact location of cylindrical axis. Produces plot of inner circumference, estimate of true center of vessel, data on radius, diameter of best-fit circle, and negative and positive deviations of radius from circle at closely spaced points on circumference. Eliminates need for time-consuming and error-prone manual measurements.
Characterization of the High-Albedo NEA 3691 Bede
NASA Technical Reports Server (NTRS)
Wooden, Diane H.; Lederer, Susan M.; Jehin, Emmanuel; Rozitis, Benjamin; Jefferson, Jeffrey D.; Nelson, Tyler W.; Dotson, Jessie L.; Ryan, Erin L.; Howell, Ellen S.; Fernandez, Yanga R.;
2016-01-01
Characterization of NEAs provides important inputs to models for atmospheric entry, risk assessment and mitigation. Diameter is a key parameter because diameter translates to kinetic energy in atmospheric entry. Diameters can be derived from the absolute magnitude, H(PA=0deg), and from thermal modeling of observed IR fluxes. For both methods, the albedo (pv) is important - high pv surfaces have cooler temperatures, larger diameters for a given Hmag, and shallower phase curves (larger slope parameter G). Thermal model parameters are coupled, however, so that a higher thermal inertia also results in a cooler surface temperature. Multiple parameters contribute to constraining the diameter. Observations made at multiple observing geometries can contribute to understanding the relationships between and potentially breaking some of the degeneracies between parameters. We present data and analyses on NEA 3691 Bede with the aim of best constraining the diameter and pv from a combination of thermal modeling and light curve analyses. We employ our UKIRT+Michelle mid-IR photometric observations of 3691 Bede's thermal emission at 2 phase angles (27&43 deg 2015-03-19 & 04-13), in addition to WISE data (33deg 2010-05-27, Mainzer+2011). Observing geometries differ by solar phase angles and by moderate changes in heliocentric distance (e.g., further distances produce somewhat cooler surface temperatures). With the NEATM model and for a constant IR beaming parameter (eta=constant), there is a family of solutions for (diameter, pv, G, eta) where G is the slope parameter from the H-G Relation. NEATM models employing Pravec+2012's choice of G=0.43, produce D=1.8 km and pv˜0.4, given that G=0.43 is assumed from studies of main belt asteroids (Warner+2009). We present an analysis of the light curve of 3691 Bede to constrain G from observations. We also investigate fitting thermophysical models (TPM, Rozitis+11) to constrain the coupled parameters of thermal inertia (Gamma) and surface roughness, which in turn affect diameter and pv. Surface composition can be related to pv. This study focuses on understanding and characterizing the dependency of parameters with the aim of constraining diameter, pv and thermal inertia for 3691 Bede.
van Wagtendonk, J.W.; Moore, P.E.
2010-01-01
Fire managers and researchers need information on fuel deposition rates to estimate future changes in fuel bed characteristics, determine when forests transition to another fire behavior fuel model, estimate future changes in fuel bed characteristics, and parameterize and validate ecosystem process models. This information is lacking for many ecosystems including the Sierra Nevada in California, USA. We investigated fuel deposition rates and stand characteristics of seven montane and four subalpine conifers in the Sierra Nevada. We collected foliage, miscellaneous bark and crown fragments, cones, and woody fuel classes from four replicate plots each in four stem diameter size classes for each species, for a total of 176 sampling sites. We used these data to develop predictive equations for each fuel class and diameter size class of each species based on stem and crown characteristics. There were consistent species and diameter class differences in the annual amount of foliage and fragments deposited. Foliage deposition rates ranged from just over 50 g m-2 year-1 in small diameter mountain hemlock stands to ???300 g m-2 year-1 for the three largest diameter classes of giant sequoia. The deposition rate for most woody fuel classes increased from the smallest diameter class stands to the largest diameter class stands. Woody fuel deposition rates varied among species as well. The rates for the smallest woody fuels ranged from 0.8 g m-2 year-1 for small diameter stands of Jeffrey pine to 126.9 g m-2 year-1 for very large diameter stands of mountain hemlock. Crown height and live crown ratio were the best predictors of fuel deposition rates for most fuel classes and species. Both characteristics reflect the amount of crown biomass including foliage and woody fuels. Relationships established in this study allow predictions of fuel loads to be made on a stand basis for each of these species under current and possible future conditions. These predictions can be used to estimate fuel treatment longevity, assist in determining fuel model transitions, and predict future changes in fuel bed characteristics.
He, F; Zheng, L; Dong, F T
2017-05-11
Objective: To compare the effects of sterilized air and perfluoropropane (C(3)F(8)) tamponades on recovery after vitrectomy for the treatment of idiopathic full-thickness macular hole (IFTMH). Methods: Case control study. Seventy-three eyes of 69 consecutive cases underwent vitrectomy with air (53 eyes) or 10% C(3)F(8) gas (20 eyes) tamponade. Surgical outcomes were retrospectively analyzed between the two groups, including logarithm of the minimal angle of resolution (logMAR) and optical coherence tomography findings like the size of the macular hole and the photoreceptor layer defect. Results: Preoperatively, the mean best corrected visual acuity (BCVA) was (0.10±0.49), the mean hole diameter was (777.9±320.7) μm, and the mean diameter of the photoreceptor layer defect was (1 709.3±516.0) μm in the sterilized air group, while in the C(3)F(8) group, the mean BCVA was (0.07±0.50), the mean hole diameter was (853.9±355.0) μm, and the mean defect diameter was (1 480.5±429.9) μm. The primary closure rate was 90.6% in the sterilized air group and 95.0% in the C(3)F(8) group. One month after surgery, the mean BCVA was (0.17±0.41), and the mean diameter of the photoreceptor layer defect was (820.5±598.0) μm in the sterilized air group, while in the C(3)F(8) group, the mean BCVA was 0.12±0.49, and the mean defect diameter was (762.5±658.0) μm. There was no statistically significant difference in the closure rate (χ(2)=0.019), BCVA ( t =-1.689), hole diameter ( t =0.837) and diameter of the photoreceptor layer defect ( t =0.338) between the two groups( P >0.05). Conclusions: Vitrectomy with sterilized air tamponade is safe and effective for the treatment of IFTMH and even cases with relatively large diameters. (Chin J Ophthalmol, 2017, 53: 327 - 331) .
Abdominal aortic aneurysm neck remodeling after open aneurysm repair.
Falkensammer, Juergen; Oldenburg, W Andrew; Biebl, Matthias; Hugl, Beate; Hakaim, Albert G; Crook, Julia E; Berland, Todd L; Paz-Fumagalli, Ricardo
2007-05-01
Proximal endovascular aortic graft fixation and maintenance of hemostatic seal depends on the long-term stability of the aortic neck. Previous investigations of aortic neck dilation mostly focused on the infrarenal aortic diameter. Fenestrated and branched stent grafts facilitate suprarenal graft fixation and may thereby improve the long-term integrity of the aortic attachment site. For these devices, the natural history of the suprarenal aortic segment is also of interest. We investigated the natural history of the supra- and infrarenal aortic segment after open abdominal aortic aneurysm (AAA) repair. For this retrospective analysis, we reviewed the preoperative and the initial postoperative as well as the most recent CT series that were obtained from 52 patients undergoing conventional repair of an infrarenal abdominal aortic aneurysm between January 1998 and December 2002. Measurements were performed using electronic calipers on a "split screen", allowing direct comparison of subsequent CT series at corresponding levels along the vessel. Main outcome measures were changes in postoperative measures of the supra- and infrarenal aortic diameters. The first postoperative exam was at a mean (+/-SD) of 7.0 +/- 3.5 months, and the final exams were at 44.4 +/- 21 months. Over this time period, the estimated rate of change in suprarenal diameter was 0.18 mm/ y with 95% confidence interval (CI) from 0.08 to 0.27. The estimated rate of change for the infrarenal diameter was 0.16 (95% CI: 0.05 to 0.27). A clinically relevant diameter increase of >or=3 mm was observed in seven patients (13%). There was evidence of larger diameter increases associated with larger AAA diameters (P = .003 and <.001 for suprarenal and infrarenal diameters), an inverted funnel shape (P = .002 and <.001), and marginal evidence of association with a history of inguinal hernia (P = .043 and .066). Although there is statistically significant evidence of increases in the supra- and infrarenal aortic diameters after conventional AAA repair, mean annual increases tended to be small and clinically relevant increases of 3 mm or more were observed in only a small proportion of cases.
Characterization of the high-albedo NEA 3691 Bede
NASA Astrophysics Data System (ADS)
Wooden, Diane H.; Lederer, Susan M.; Jehin, Emmanuel; Rozitis, Benjamin; Jefferson, Jeffrey D.; Nelson, Tyler W.; Dotson, Jessie L.; Ryan, Erin L.; Howell, Ellen S.; Fernandez, Yanga R.; Lovell, Amy J.; Woodward, Charles E.; Harker, David Emerson
2016-10-01
Characterization of NEAs provides important inputs to models for atmospheric entry, risk assessment and mitigation. Diameter is a key parameter because diameter translates to kinetic energy in atmospheric entry. Diameters can be derived from the absolute magnitude, H(PA=0deg), and from thermal modeling of observed IR fluxes. For both methods, the albedo (pv) is important - high pv surfaces have cooler temperatures, larger diameters for a given Hmag, and shallower phase curves (larger slope parameter G). Thermal model parameters are coupled, however, so that a higher thermal inertia also results in a cooler surface temperature. Multiple parameters contribute to constraining the diameter.Observations made at multiple observing geometries can contribute to understanding the relationships between and potentially breaking some of the degeneracies between parameters. We present data and analyses on NEA 3691 Bede with the aim of best constraining the diameter and pv from a combination of thermal modeling and light curve analyses. We employ our UKIRT+Michelle mid-IR photometric observations of 3691 Bede's thermal emission at 2 phase angles (27&43 deg 2015-03-19 & 04-13), in addition to WISE data (33deg 2010-05-27, Mainzer+2011).Observing geometries differ by solar phase angles and by moderate changes in heliocentric distance (e.g., further distances produce somewhat cooler surface temperatures). With the NEATM model and for a constant IR beaming parameter (eta=constant), there is a family of solutions for (diameter, pv, G, eta) where G is the slope parameter from the H-G Relation. NEATM models employing Pravec+2012's choice of G=0.43, produce D=1.8 km and pv≈0.4, given that G=0.43 is assumed from studies of main belt asteroids (Warner+2009). We present an analysis of the light curve of 3691 Bede to constrain G from observations. We also investigate fitting thermophysical models (TPM, Rozitis+11) to constrain the coupled parameters of thermal inertia (Gamma) and surface roughness, which in turn affect diameter and pv. Surface composition can be related to pv. This study focuses on understanding and characterizing the dependency of parameters with the aim of constraining diameter, pv and thermal inertia for 3691 Bede.